Loading...
HomeMy WebLinkAbout33668-ZFORM NO. 4 TOWN OF SOUTHOLD BUILDING DEP~RTMENT Office of the Building Inspector Town Hall Southold, N.Y. CERTIFICATE OF OCCUPANCY No: Z-33389 Date: 11/14/08 THIS CERTIFIES that the building INTERIOR ALTERATIONS Location of Property: 22655 SOUNDVIEW AVE (HOUSE NO.) (STREET) County Tax Map No. 473889 Section 135 Block 1 Subdivision Filed Map No. Lot No. SOUTHOLD Lot 26 ( HAMLET ) conforms substantially to the Application for Building Permit heretofore filed in this office dated JANUARY 28, 2008 pursuant to which Building Permit No. 33668-Z dated FEBRUARy 5, 2008 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is INTERIOR ALTERATIONS TO AN EXISTING ONE FAMILY DWELLING AS APPLIED FOR. The certificate is issued to NICK S POLOGEORGIS (OWNER) of the aforesaid building. S~FOIaK C~DI~YDEPARTT~ENT OF }~ALTHAPPRO%~%L N/A EL~C-£KICAL U~RTIFICATE NO. 125852C 11/07/08 PL~ CE~TIFIC3%TION DA'r~ 11/03/08 TODD DAWSON /~thotz~d ~lgnature Rev. 1/81 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings, property lines, streets, and unusual natural or topographic features. 2. Final Approval from Healtl~ Dept. of water supply and sewerage-disposal (S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead. 5. Co~mnereial building, industrial building, multiple residences and similar buildings and installations, a cerlificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements~ B~ For existing buildings (prior to April 9, 1957) non-conforming uses, or buildings and "pre-existing" land uses: 1. Accurate survey ofp~opmly showing all proper%, lines, streets, buildmg and umlsua[ natural or topographic features. · 2. A properly completed application and consent Io respect sig~md by the applicant. Ifa Certificate of Occupancy is denied, the Building lnspecto~ shall state the reasons therefor in writing to the applicant. C. Fees I Certificate of Occupancy New dwelling $25.00, Additions to dwelling $25.00, Alterations to dwelling $25 00, Switmning pool $25.00, Accessory building $2500, Additions to accesso~3, building $2500, Businesses $5000. 2. Certificate of Occupancy on Pre-existing Buitdiug - $100.00 3 Copy of Certificate of Occupancy - $25 ,4 Updated Certificate of Occupancy - $5000 5. Temporary Certificate of Occupancy - Residential $1500, Counnercia11215.00 Date. till 2.- Old or Pre-existing Building: New Coustm~ction: Location of Propmly: _ House No. Owner or Owners ofP-opeily: .fi4 tek Suffolk C6unty Tax Map No 1000, Section Subdivision Pem~it No "Z~'~ ¢ ~2 g Date Of PeHlalt. Health Dept. Approval: ~) ~ Plmming Board Approval: ~ o Request for: Temporary Certificate Fee Submitted: $ .~r-~......__ _ (check one) Street Hamlet Block / Lot _e.~¢(..~ __ Filed Map. __ .... Lot: Underwriters Approval: ~,~ -~ (check one) Applicant Signature Final Ce~.ificate: Town Halt, 53095 Main Road P.O. Box 1179 Southold, New York 11971-0959 Fax (631) 765-9502 Telephone (631) 765-1802 BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATION Building Permit No. ~_.~r& Owner: ~)O i 0 ~' ~.d "~ (Please print) Plumber:--F~)~ ~~V (Please print) I certify that the solder used in the water supply system contains less than 2/10 of 1% lead. Sworn to before me this ~ ~t~ Notary Publi County Commissi~ E~i~ ~. 31,~ (Plumbers Signature) Issue Date 11/7/2008 Electrical Inspection Certificate Electrical Inspection Service, Inc. Application Number 375 Dunton Avenue 125852C East Patchogue, New York 11772 (631) 286-6642 Issued To: Street: Village: Section: Nick Pologeorgis 22655 Soundview Avenue Southold Block: Zip: 11971 Town: Southold Lot: Contractor: Shore Power Elec. Cont. Inc. Lic. # 42536-ME Was examined and found to be in compliance with the National Electrical Code. [] Commercial F I NVDefects ~ Pool [] lstFIoor ~ Indoor ~ Basement ~ HotTub I~ Residential _~ Der. Garage ~ Attic x~ 2nd Floor [ J Outdoor [~ Addition [~ Survey Switches Receptacles Fixtures GFI Heaters 3 4 1 Dishwasher Washer/Amps Dryer/Amps Oven Range/Amps A/C Fans Microwaves Furnace Oil Gas Circulators Smoke Detector Bell Transformer 1 Meter Amps Phase UG/OH Jacuzzi Television CO Detector / 2 Bldg. Permit: 33668 Other Equipment I-Smoke Detector/1-sD/Co combo Hugo S. Surd/ President ~ugh [n~pection: ~ ~o~: ~/05 0 ~ns~or: John Mc Mahon III This certificate must not be altered in any manner. Inspectors may be identified by their credentials. FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 33668 Z Date FEBRUARY 5, 2008 Permission is hereby granted to: for : NICK S POLOGEORGIS 143 WEST 29TH STREET NEW YORK,NY 10001 INTERIOR ALTERATION TO AN EXISTING SINGLE FAMILY DWELLING AS APPLIED FOR at premises located at County Tax Map No. 473889 Section 135 pursuant to application dated JANUARY Building Inspector to expire on AUGUST 22655 SOUNDVIEW AVE SOUTHOLD Block 0001 Lot No. 026 28, 2008 and approved by the 5, 2009. Fee $ 200.00 Aut h~ri~lz e d Signature ORIGINAL Rev. 5/8/02 TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INS~U~ATION [ ] FRAMING / STRAPPING [ *.~FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION DATE /9/,~ P~/~'2~:> , N S PECTO R ~ TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 I NSPECT T ION [ ] FOUNDATION 1ST [ ~ ROUGH PLBG. [ ]F/.OUNDATION 2ND [ ]INSULATION [,/] FRAMING / STRAPPING [ ]FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] RRE RESISTANT CONSTRUCTION [ REMAflKS: ~ ] FIRE RESISTANT PENETRATION DATE ~ INSPECTOR TOWN OF ~OUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ]F/OUNDATION2ND [ ]INSULATION [,,/] FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: ,~/~ 4¢ ~ ~J~.r DATE INSPECTOR ?I]gLD INSPECTION REPORT I DATE [ COiVIMENTS ~ ~ FOUNDATION (1ST) ~'~ :~ ....................................... FOt~DATION (2ND) ~ ROUGH F~G & ~' pLt~G ~ STATE ENERGY CODE ~ ~DITION~ CO~S ~ m OF SOUTHOLD ~OPERTY RECORD CARD OWNER RES?~ SEAS. ] VL. STREET '~7 "..;, ~ z~f~, VILLAGE FARM COMM. DISTRICT SUB. ACREAGE TypI: OF BIjILDING LOT CB. t MISC. LAND IMP. TOTAL DATE REMARKS i Tillable 3 Woodland Swampland Brushland House Plot Extension Foundation Basement Ext. Walls Fire Place Patio Driveway Porch Porch Bath Floors Interior Finish Hec~t Attic Rooms 1st Floor Rooms 2nd Floor OWNER LANO IMP. TOWN OF SOUTHOLD PROPERT~ STREET VILLAGE ACR. REMARKS 'YPE OF BLD. PROP. CLASS TOTAL DATE FRONTAGE ON WATER FRONTAGE ON ROAD DEPTH BULKHEAD TILLABLE WOODLAND MEADOWLAND HOUSE/LOT TOTAL I I I | I I · IIIII 135.-1-26 4/0? ~M ~B~'~4. · (' 17 ~ '~ ~""""""""'~'-) ?-' "'~' [ 0 (~ '~ ~ 6.~ 65Z~ Foundation c. .c Bath 5 Dinette Ext~n~idn-- (O0~T' ¢ ~%5~ Basement s~.c"*w~ ~././,~ Floors Kit Extension Ext. Walls C~ Interior Finish L,R. Extension FirePlace V~¢} Heat ¢~ , ~(* D.R. Patio Woodst~ve BR. Deck ~ X ~ ¢ ~ -~ ¢2 Attic Breezeway Rooms 1st Floor Garage ~ [5 ~=A~ 17~ ~ Driveway Rooms 2nd Floor Pool ~ ~ 135-1-26 4/01 M Bldg Extension Extension Foundation c. Bath Basement sL^~ 'v' :'" ~ Floors Ext Walls c'"',- ,~ ~ ~, ~ nter~or Finish TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL SOUTHOLD, NY 11971 TEL: (631) 765-1802 FAX: (631) 765-9502 SoutholdTown.NorthFork.net Examined Approved Disapproved a/c Expiration ~/~'~, 20 0 / PERMIT NO. ! Building Inspector BUILDING PERMIT APPLICATION CHECKLIST Do you have or need the following, before applying? Board of Health 4 sets of Building Plans Planning Board approval Survey Check Septic Form N.Y.S.D.E.C. Trustees Flood Permit Storm-Water Assessment Form Contact: Mail to: Phone: APPLICATION FOR BUILDING PERMIT Date ,20 INSTRUCTIONS a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale. Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application, the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e. No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months al~er the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim, the Building Inspector may authorize, in writing, the extension of the permit for an addition six months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County, New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances, building code, housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. (Signature of applicant or name, ifa corporation) (Mailing address of applicant) State whether applicant is ow_ner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder '~ Name of owner of premises ¢! '\ C .~. (As on thMax roll'or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. Plumbers License No. Electricians License No. Other Trade's License No. 1. Locatio~..oLland-cm~hich provosed work will be done: House Number Street County Tax Map No. 1000 Section Subdivision Filed Map No. Hamlet Lot State existing use and occupancy of premises,and inte~lded use and occrtpanc, y~.of proposed construction: a. Existinguseandoccupancy k.hwelll b. Intended use and occupancy Nature of work (check which applicable): New Building. Repair Removal Demolition 4. Estimated Cost lO/ 0tgO 5. If dwelling, number of dwelling units If garage, number of cars Fee Addition Alteration Other Work (Description) (To be paid on filing this application) Number of dwelling units on each floor 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front Height. Number of Stories Rear Depth Dimensions of same structure with alterations or additions: Front Depth Height Number of Stories Rear 8. Dimensions of entire new construction: Front Height Number of Stories Rear .Depth 9. Sizeoflot: Front Rear .Depth 10. Date of Purchase Name of Former Owner 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation? YES __ NO__ 13. Will lot be re-graded? YES NO ){ Will excess fill be removed from premises? YES NO__ 14. Names of Owl~ex of premises Name of ~A~-e~'~ct Name of Contractor Address Address Address Phone No. Phone No Phone No. 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES X NO __ * IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet ofa tidal wetland? * YES ~ NO__ * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? * YES__ NO ~ · IF YES, PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTYOF j~.~. , ~0/ ~ k, ~,,~ G ~¢'"°{5' 5 being duly sworn, deposes and says that (s)h_.~e is the applicant (Name of indivi~lual signing contract)~above named, (S)He is the (Contractor, Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. Sworn to before me this /~ ~,~J,,~dayof ~-~.~_~t/._~j/ 20 ~J> / lqotary Public Notary public, ~>tate of Ne No. 02CA6018386 Qualified in Richmond County CommiSsion Expires Jan. 14, 201t LONG ISLAND SOUND APPARENT HIGH WATER LINE 5-10-05 N 75-01-40 E -B TAX LOT 25.1 1 STY FRAME SAND I WALL SAND 101.62 BEACH CRASS ...... x~ ~.~- - 11 TIMBER U~HT SAND TAX LOT # 22655 50.6' CLF STK TO BE REMOVED PROPOSED GARAGE SITE LAYOUT TAX LOT 27 PROPOSED ~,~ o.o PROPOSED STK AND BUILDING DESIGN BY OTHERS LANDSCAPED DRIVEWAY / NOTE: CONTOUR LINES REFERENCED TO NGVD 29 NOTE: LOT AIREA 24,682 SO, FT, MAIN BUILDING 1,722 SQ. FT. PORCHES~ STEPS AND PADS 1,015 SQ. FT, TOTAL 2,755 SQ. FT. PROPOSED GARAGE AREA 450 SQ. FT. BUFFER DECIDUOUS PLANTING EVERGREEN PLANTING COASTAL EROSION HAZARD LINE SCALED FROM NYS DEC MAP IM]'ROVEMENT SURVEY SI~T I OF 1 ANGLE OF ATTACK LAND SURVEYING, LLC 1007 S. ]EI~EY AVE. SETAUKET, NY 11733 - -- ,,-0--~-, 0 ....... ~,_.~,,,_ .................. ~ ..................... __~___., .......... j; ..... ~ ..................... j, FOUNDATION PLAN SCALE: 1/4" = 1'-0' GARAGE o¢ U$ WI' OI )UPANCY ilS UNLAWFUL HOUT CEr-:l iFICATE )CCIJPANCY J/VIDF--R CER,TIFIOA TION LEAD CONT. EN? DE, FORE OF O~CUPANC¥ ,LDER USED IN WATER ,'STEM CANNOT 90FI%LEAD. PLUMB NG L PLUMBING WASTE NEED TE ~ ~G BEFOR'ECOVERING- ~PROVED AS NOTED NOTIFY BUILDING DEPARTMENT AT 765-1802 DAM TO 4PM FOR THE FOLLOWING INSPECTIONS: 1, FOUNDATION - FWO REQUIRED ALL CONSTRUCTION SHALL FOR POURED CONCRETE MEET THE REQUIREMENTS OF II. UGH - FRAMING & PLUMSING CODES OF NEW YORK STATE: INSULATION 4, FINAL - CONS1RUCT"ON MUST SE C~)MPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR CERTIFICATION OF DESIGN OR CONSTRUCTION ERRORS. NAILING & CONNECTIONS REQUIRED. UNDERWRITERS CERTI~:'[C~ ' ,~ R,E~!F~D DRAWN BY: ]F/NIH ]anuary 14, 2008 ~CALE: 1/4" = 1'-0" ~HEET NO CLOSET i 000 -- ~VING ROOM -- * ENTRY K~CHEN ~ H MECHANZCAL ROOM ~ - )o~~ D~WN BY: JF/MH , ]anua~ ~4, 2008 ' , SCALE: 1/4"= 1'-0" WALL LEGEND I , SHEET NO 1STscALE:. FLOOR~/4,,: ~,-o,PLAN , ............... INTERIOR ELEVATION AT BEDROOM QLOW // ~EDROOH y BRIDGE m m , : l ~ " BATH PROPOSED BEDROOH m ~ /, {~ISTIN~) 5K· ~1 ' ' ' ,, o ~ I I u I {, ,, 2ND FLOOR PLAN "', ," DRAWN BY: IF/MH Ianuary 14, 2008 SCALE: 1/4" = 1'-0" WALL LEGEND 3HEET NO: .............. ~ WALL TO BE REMOVED WIND LOAD PATH CONNECTION AND CONSTRUCTION DETAIL DRAWINGS JOIST I I · ~ 121. DR~WN BY: ]F/MH Januarg 14, 2008 SCALE: 1/4" = 1'-0" SHEET NO GENERAL NOTES CONSTRUCTION NOTES: FOUNDATION NOTES: FRAMING NOTES WIND FRAMING NOTES I) RIDGE TO RAFTER ASSEMBLY: 1-114' x 20 gauge strap shall be altsched to each pair of raEers In accordance to table 3.4 DECK AND COVERED PORCH NOTES: 4), Deck joists to have blocking al 8'0 o c 5). A minimum of 10 inch flashing shall be Installed between the building and ledger PLUMBING NOTES HVAC SYSTEM NOTES ELECTRICAL NOTES: ALTHOUGH EVERY EFFORT HAS SEEN MADE rN PREPARING THESE PLANS AND CHECKING THEM FOR ACCURACY, THE CONTRACTOR MUST CHECK ALL DETAILS AND DIMENSFONS AND BE RESPONSIBLE FOR THE SAME FOR ALL GOVERNING CODES AND BUILDING PRACTICES THESE DRAWINGS CONFORM TO GENERALLY ACCEPTED BUILDING PRACTICES; HOWEVER STATE AND LOCAL CODES VARY WIDELY THE DESIGNER SHALL NOT BE HELD LIABLE FOR ANY ERRORS. ALL CONSTRUCTION SHALL COMPLY WITH ALL APPLICABLE STATE AND LOCAL CODES. DO NOT SCALE DRAWINGS, USE ONLY THE PRINTED NAILING SCHEDULE ROOF FRAMING: JOINT DESCRIPTION NAIL NAIL QTY SPACINE NOTES RA~TER TO 8" WALL 3~d COMMON EACH TOE-NAIl TOP pLATE 10' WALL: 4~8d COMMON ~FTER CEILING JOIST 8' WALL' 3~d COMMON EACH TO TOP plaTE 10' WALL: 4-8d COMMON JOIST TOE-NAIl CEILING JOIST TO AS PER TABLE 3 7 EACH FACE PARALLEL RAFTER WFCM - SEC LAP NAIL CEILING JOIST LAps AS PER TABLE 37 EACH FACE OVER PARTITION WFCM - SEC LAp NAIL COLLAR T~E AS PER TABLE 3.4 EACH FACE TO RAFTER WFCM - SEC END NAIL BLOCKING EACH TOE TO RAFTER 2 - Sd COMMON END NAIL RIM BOARD E~CH END TO RAFTER 2 ~ 16d COMMON END NAIL WALL FRAMING: JOINT DESCRIPTION NAIL NAiL NOTES QTY SPACING TOP PLATE TO PER FACE NAIL TOP PLATE ! - l§d COMMO~ FOOT SEE NOTE: 1 TOP pLATES AT JOINTS FADE INTERSECTIONS ~- 16d COMMO~ EA SIDE NAIL STUD TO 24" FACE FLOOR FRAMING: JOINT DESCRIPTION NAIL NAIL QTY. ~PACING NOTES JOIST TO: PER TOE ~ILL= TOP PLATE OR GIRDER 4 - 8d COMMON JOIST NAIL ~RIDGING EACH TOE TO JOIST 2 - 8d COMMON END NAIL BLOCKING 2- 8dCOMMON EACH TOE TOJOtST END J NAiL ~LOCKING TO- ~ACH TOE :{OOF SHEATI- lNG: CEILING SHEATHING: WALL SHEATHING: JOINT DEBCRIPTIDN NAIL NAiL QTY. GPACIN~ PANELS ad COMMON WFCM · SEC pLYWOOD 6d COMMON 6" O C FIELD GYPSUM 7" O.C. EDgE WALLBOARD 5d COOLERS 10" [3 C FIELD FLOOR SHEATHING: NAIL NAIL JOINT DESCRIPTION QTY. SPACING 1' OR LESS 8d COMMON 12" D.C. FIELD STRUCTURAL PANELS 6I' O.C. EDgE NOTES~.' THESE NOTES ARE ONLY TO BE REFERRED TO IF MENTIONED IN SCHEDULE NOTES ONLY 1 } Nailing requirements are based on wall sheathin~ nailed 6" on,enter at the panel edge If wa)l ahea~lng PLAN CONTENTS: OCCUPANCY C LASSIEICATION R3 RESIDENTIAL BUILDING USE RESIDENTIAL DWELLING BUILDING HEIGHT NO CHANGE TOTAL SQFT OF CONSTRUCTION (SEE FLOOR PL~.N ) DESIGN CRITERIA 3RESCRIPTIVE AS PER N.Y.S. RESIDENTIAL CONSTRUCTION CODE AND 2~06 SEC HIGH WIND EDITION~ WOOD FRAME CONSTRUCTION MANUAL FRAMING ELEMENTS AS PER FLOOR PLANS~ CROSS SECTION AND GENERAL NOTES EXT BALCONIES 60 DECKS 40 ATI ICS w/o STORAGE 10 ATTICS w/STORAGE 20 DESIGN LOAD CALCULATIONS ROOF iGROUNO SNOW LOAD) 2~ (LIVE LOADS PSF) ROOMS (OTHER THAN SLEEPING) 40 ROOMS (SLEEPING) 30 STAIRS 40 GAURDRAILS (ANY DIRECTION) 200 EXPOSLIRE CATAGORY C LOAD PATH SEE CONSTRUCTION ANDWIND PATH CONNECTION (ROOF ~ FOUNDATION) DETAIL PAGE & GENERAL NOTE PAGE NAILING SCHEDULE SEE GENERAL NOTE PAGE EGRESS SEE FLOOR PLANS AND WINDOW SCHEDULE FIRE PROTECTION ~ym: J ISMOKE & CO DETECTORS) I~I SEE FLOOR PLANS TRUSS DESIGN N/A - STANDARD STICK FRAME CONSTRUCTION ENERGY CALCULATIONS RESCHECK CLIMATIC & GEOGRAPHIC DESIGN CRITERIA GROUND WIND SEISMIC FROST WINTER ICE~HIELD FLOOD SNOW SPEED DESIGN WEATHERING LINE TERMITE DECAY DESIGN UNDERLAYMENT H~ARDS LOAD (MPH) CATEGORy DEPTH TEMP. REQUIRED ROOF SHEATHING REQUIREMENTS FOR WIND LOADS: SH F~.THING LO CATION NAIL SPACING NAIL SPACING AT INTERMEDIA I~ NOTES GABLE ENDWALL RAKE AND RAKE TRUSSAT PANEL EDGES SUPPORTS IN THE PANEL FIELD 4' PERIMETER EDGE ZONE 8d COMMON {~ 6" O C. 8d COMMON ~ 6" O.C SEE NOTES: 1.3 NOTE~S THESE NOTES ARE ONLY TG BE REFERRED TO IF MENTIONED IN SCHEDULE NOTES ONLY, WALL SHEATHING REQUIREMENTS FOR WIND LOADS: NAIL SPACING NAIL SPADING AT INTERMEDIATE ~HEATHING LOCATION AT PANEL EDGES SUPPORTS IN THE PANEL FIELD NOTES 4' EDGE ZONE Bd COMMON ~ 6" O C ,, SEE NOTES 1, 3 ( BOTH FIELDS) 8d COMMON (~ 6" O,C Bd COMMON ~ 12 DC NOTE' 2 FOR PANEL FIELD NOTES THESE NOTES ARE ONLY TO BE REFERRED TO IF MENTIDNED IN SCHEDULE NOTES ONLY. NOTE: CONTRACTOR TO PROVIDE SOIL TEST TO VERIFY EXISTING CONDITIONS. MINIMUM 3000# CAPACITY. 0 SCALE: 1/4" = 1'-0" SHEET NO