Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
33850-Z
FORM NO. 4 TOWN OF SOUTHOLD BUILDING DEPARTMENT Office of the Building Inspector Town Hall Southold, N.Y. CERTIFICATE OF OCCUPANCY No: Z-33348 Date: 10/22/08 THIS c~KTIFIES that the building ADDITIONS/ALTERATIONS Location of Property: 1585 BREAKWATER RD (HOUSE NO.) (STREET) County Tax Map No. 473889 Section 106 Block 8 Subdivision Filed Map No. Lot No. MATTITUCK ( HAMLET ) Lot 20.4 conforms substantially to the Application for Building Permit heretofore filed in this office dated APRIL 18, 2008 pursuant to which Building Permit No. 33850-Z dated APRIL 23, 2008 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is ADDITION AND ALTERATIONS TO AN EXISTING ONE FAMILY DWELLING AS APPLIED FOR PER ZBA ~6036, DATED 6/14/07. The certificate is issued to SUSAN EMANUELE of the aforesaid building. (OWNER) SUFP%)I~K COI]N~I~f DEPART~T OF }{]F~kLTH APPRO~-AL N/A EIxEt-rKIC3%L C~TIFICATH NO. 4007612 10/15/08 PLI~4B~ c~KTIFICATION DA'r~u3 10/15/08 PECONIC PLLD4BING & HEAT orized Signature Rev. 1/81 Form No. 6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings, property lines~ streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead. 5. Commercial building, industrial building, multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Plarming Board Approval of completed site plan requirements. For existing buildings (prior to April 9, 1957) non-conforming uses, or buildings and "pre-existing" land uses: 1. Accurate survey of'property showing all property lines, streets, building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied, the Building Inspector shall state the reasons theretbr in writing to the applicant. C. Fees 1. Certificate of Occupancy - New dwelling $25.00, Additions to dwelling $25.00, Alteratious to dwelling $25.00, Swimming pool $25.00, Accessory huildiug $25.00, Additions to accessnry building $25.00, Businesses $50.00. · 2. Certificate of Occupancy on Pre-existiug Building- $100.00 3. Copy of Certificate of Occupancy - $.25 4. Updated Certificate of()ccupaucy - $50.00 5. Temporary Certificate ofOccupaucy - Residential $15.00, Commercial $15.00 New Constrnction: Location of Property: Old or Pre-existing Building: (check one) Street ltamlet House No. Ow er or Owner of Property: Block ~*'"iED~. Lot Filed Mai>. Lot: [2-~! O ~ Applicant: Underwriters Approval: Fiual Certificate:/'~V///' (check one) /)~pplEut~ Permit No. 3 5~,.5-'-O Date of Perufit. Health Dept. Approval: Planning Board Approval: Request for: Temporary Certificate Fee Submitted: $ O,~i Suffolk County Tax Map No 1000, Section Subdivision Town Hall, 53095 Main Road P.O. BOX 1179 Southold, New York 11971-(1959 Fax (631) 765-9502 Telephone (631 ) 765-1802 BUILDING DEPARTMENT TOW~N OF SOUTHOLD CERTIFICATION Building Permit No. Owner: ~O b S~ Plumber: lead. (please print) (please print) I certify that the solder used in the water supply system contains less than 2/10 of 1% Sworn to before me this d~(yof ~___-~-~ , 200c~] VIC81L. LOPER NO. OI[OGU/UUAL Q,sar, q~ in ~ dk~Co~ ny~ BY THIS CERTIFICATE OF COMPLIANCE THE NEW YORK BOARD OF FlEE UNDERWRITERS BUREAU OF ELECTRICITY 40 FULTON STREET ~ NEW YORK, NY 10038 CERTIFIES THAT Upon the application of upon premises owned by PAUL R. BURNS SUSAN EMANUELLE PO BOX 1061 1385 BREAKVVATER ROAD SOUTHOLD, NY 11971-0932, MATTITUCK, NY 11952 Located at 1385 BREAKWATER ROAD MATTITUCK, NY 11952 Application Number: 4007612 Certificate Number: 40076t2 Section: Block: Lot: Building Permit: . BDC: ns11 Described as a Residential occupancy, wherein the premises electrical system consisting of described below, located in/on the premises at: electrical devices and wiring, Basement, First Floor, Outside, A visual inspection of the premises electrical system, limited to electrical devices and wiring to the extent detailed herein, was conducted in accordance with the requirements of the applicable code and/or standard promulgated by the State of New York, Department of State Code Enforcement and Administration, or other authority having jurisdiction, and found to be in compliance therewith on the lS~ Day of Octeber, 2008. Name OTY Rathe Rat/hR Circuils Tv~e AdditionalCharges bed room addition Alarm and emergency equipment Sensor I 0 0 Carbon Monoxide Sensor 4 0 0 Smoke Appliances and Accessories Air Conditioner 2 0 Above 1500 BTU Exhaust Fan I 0 F.H.P Panels Wiring And Devices Dimme~ I 0 120 V Outlet 18 0 Gen, purpose Receptacle 9 0 Gert, This certificate may not be altered in any way and is validated only by the presence of a raised seal at the location indicated. BY THIS CERTIFICATE OF COMPLIANCE THE NEW YORK BOARD OF FIRE UNDERWRITERS BUREAU OF ELECTRICITY 40 FULTON STRE~-J ~ NEW YORK, NY 10038 CERTIFIES THAT Upon the application of upon premises owned by PAUL R. BURNS SUSAN EMANUELLE PO BOX 1061 1385 BREAKWATER ROAD SOUTHOLD, NY 11971q3932, MATTITUCK, NY 11952 Located at - 1385 BREAKVVATER ROAD MA'FFITUCK, NY 1 t952 Application Number: Certificate Number: 4007612 4007612 Section: Block: Lot: Building Permit: . BDO: ns 11 Described as a Rasidenti. I occupancy, wherein the premises electrical system consisting of electrical devices and wiring, described below, located in/on the premises at: Basement, First Floor, Outside, A visual inspection of the premises electrical system, limited to electrical devices and wiring to the extent detailed herein, was conducted in accordance with the requirements of the applicable code and/or standard promulgated by the State of New York, Department of State Code Enforcement and Administration, or other authority having jurisdiction, and found to be in compliance therewith on the ]sth Day of Oct~r, zoos. Name OTY Rate Ratin~ Circuits Switch 9 0 Gen, Purpose seal 2 of 2 This certificate may not be altered in any way and is validated only by the presence of a raised seal at the location indicated. FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 33850 Z Date APRIL 23, 2008 Permission is hereby granted to: SUSAN EMANUELE 1585 BREAKWATER RD MATTITUCK,NY 11952 for : ADDITIONS AND ALTERATIONS TO AN EXISTING SINGLE FAMILY DWELLING AS APPLIED FOR PER ZBA at premises located at 1585 BREAKWATER RD MATTITUCK County Tax Map No. 473889 Section 106 Block 0008 Lot No. 020. 004 to application dated APRIL 18, 2008 a~d apprgs~ed by~the pursuant 09'~'~' ~~ Building Inspector to expire on OCTOBER 2/~3, 20 ',-7._.J~t ho r ± z eql ~k~:~nat:ure ORIGINAL Rev. 5/8/02 TOWN OF SOUTHOLD BUILDING DEPT. 765- t 802 INSPECTION [ ]FOUNDATION 1ST [ ]FOUNDATION 2ND [ ]FRAMING / STRAPPING [ ] ROUGH PLBG. [ ] INSULATION /~FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE RESISTANT CONSTRUCTION [ REMARKS: ] FIRE SAFETY INSPECTION ] FIRE RESISTANT PENETRATION INSPECTOR TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND ~"INSULATION [ ]FRAMING / STRAPPING [ ]FIREPLACE & CHIMNEY [ ]FIRE RESISTANT CONSTRUCTION [ ] FINAL [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT PENETRATION REMARKS:~ DATE TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST L.~OUGH PLBG. [ ] FOUNDATION 2ND [ ]INSULATION STRAPPING [ ]FINAL [ ] FIREPLACE & CHIMNEY [ ]FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION ] FIREPLACE & CHIMNEY ] FIRE RESISTANT CONSTRUCTION REMARKS: ] FIRE SAFETY INSPECTION ] FIRE RESISTANT PENETRATION DATE TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST ~ FOUNDATION 2ND FRAMING / STRAPPING FIREPLACE & CHIMNEY FIRE RESISTANT CONSTRUCTION REMARKS: [ ] ROUGH PLBG. [ ] INSULATION [ ] FINAL [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANI' PENETRATION DATE TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION ~ FOUNDATION 1ST [ ] FOUNDATION 2ND [ ] FRAMING / STRAPPING [ ] FIREPLACE & CHIMNEY [ ] FIRE RESISTANT CONSTRUCTION ] ROUGH PLBG. ] INSULATION ] FINAL ] FIRE SAFETY INSPECTION ] FIRE RESISTANT PENETRATION REMARKS: DATE Fl:ELD ~rSPECTION REPORT i DATE STATE ENERGY CODE ~DI~ON~ CO~S TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL SOUTHOLD, NY 11971 TEL: (631) 765-1802 FAX: (631) 765-9502 SoutholdTown. NorthFork.net Examined ! /]. 1, 20~_ff/ Approved ,20 Disapproved aJc Expiration 20__ BUILDING PERMIT APPLICATION CHECKLIST PERMIT NO. Do you have or need the following, before applying'? Board of Health 4 sets of Building Plans Planning Board approval Survey Check Septic Form N.Y.S.D.E.C. Trustees Flood Permit Storm-Water Assessment Form Contact: Mail to: Phone: 7~5- i ~/0 APPLICATION FOR BUILDING PERMIT Date INSTRUCTIONS a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale. Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or arehs, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application, the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e. No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim, the Building Inspector may authorize, in writing, the extension of the permit for an addition six months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County, New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with ali applicable laws, ordinances, building code, housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. (Signature of applicant or name, if a corporation) (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder Name of owner of premises 5"~©~/~ If app ' ant is a c(o~porat' tgnature f duly f// (Name and ~of corporate officer) ~3~lders License No. Plumbers License No. Electricians License No. Other Trade's License No. (As on the tax roll or latest deed) authorized officer 1. Location of land on which proposed work will be done: House Number Street County Tax Map No. 1000 Section Subdivision Hamlet Block t5 ~ Lot 2.D . ¢ Filed Map No. Lot State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy ~r,O~ C~ /%~ t t_._? t~z~5~'~ 6>,/C__~ b. Intended use and occupancy 5r~''vt(z-'''- t.~ [ f4~9~t ~"7od ,... 3. Nature of work (check which applicable): New Building_ Addition ~ Alteration Repair Removal Demolition Other Work Fee 4. Estimated Cost 5. If dwelling, number of dwelling units If garage, number of cars (Description) (To be paid on filing this application) Number of dwelling units on each floor 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front Height Number of Stories Rear Depth Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories ~': 8. Dimensions of entire new construction: Front Height Number of Stories Rear .Depth 9. Size of lot: Front Rear .Depth 10. Date of Purchase Name of Former Owner 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation? YES __ NO 13. Will lot be re-graded? YES __ NO Will excess fill be removed from premises? YES__ NO 14. Names of Owner of premises Name of Architect Name of Contractor Address Phone No. Address Phone No Address Phone No. 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES__ * IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet ora tidal wetland? * YES__ NO * IF YES, D.E.C. PERMITS MAY BE REQUIRED. NO J 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? * YES__ · IF YES, PROVIDE A COPY. NO STATE OF NEW YORK) SS: COt TY OFS q:oi ¢ ) ,..~A ~'D ,.J C C..-~7~, ~J/¥(~'---~being duly sworn, deposes and says that (s)he is the applicant (Name of individual signing contract) above named, (S)He is the (Contractor, Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the mmmer set forth in the application filed therewith. Sworn to before me this /~dayof /4p/) I 20f~'~:/ / ~" ~ CHRISTINE FOSTER q~l~d In Suffolk Coun~ Commi~lon Expires November lO, 2011 Signat o/f~'~Applicant ~PPEALS BOARD MEMBERS Ruth D. Oliva, Chairwoman Gerard E Goehringer James Dinizio, Jn Michael A. Simon Leslie Kanes Weisman Mailing Address: Southold Town Hall 53095 Main Road · P.O. Box 1179 Southold, NY 11971-0959 Office Location: Town Annex/First Floor, North Fork Bank 54375 Main Road (at Youngs Avenue) Southold, NY 11971 http://southoldtown.northfork.net ZONING BOARD OF APPEALS TOWN OF SOUTHOLD Tel. (631) 765-1809 · Fax (631) 765-9064 ._.EINIDINGS, DELIBERATIONS AND DETERMINATION MEETING OF JUNE 14, 2007 ZB File No. 6036 - Susan Emanuele Property Location: 1585 Breakwater Road, Mattituck CTM 106-8-20.4 SEQRA DETERMINATION: The Zoning Board of Appeals has visited the property under consideration in this application and determines that this review falls under the Type II category of the State's List of Actions, without further steps under SEQRA. PROPERTY FACTS/DESCRIPTION: The applicant's 40,000 square foot parcel is a conforming lot in the R-40 Low-Density Residential Zone District. The property has 195 feet along the west side of Breakwater Road (Luthers Road) and a depth of 200 feet, and is improved with a single-family dwelling as shown on the April 13, 2007 survey prepared by Joseph A. Ingegno.. BASIS OF APPLICATION: Request for a Variance under Section 280-124, based on the Building Inspector's January 30, 2007 Notice of Disapproval concerning an application for a building permit to construct additions and alterations to the existing dwelling, for the reason that the new construction will be less than the code- required minimum of 15 feet on a single side yard. FINDINGS OF FACT The Zoning Board of Appeals held a public hearing on this application on May 31, 2007, at which time written and oral evidence were presented. Based upon all testimony, documentation, personal inspection of the properly, and other evidence, the Zoning Board finds the following facts to be true and relevant: AREA VARIANCE RELIEF REQUESTED: The applicant wishes to construct a 15 ft. wide by 32 ft. deep, one- story addition at the south side of their existing dwelling, after removal of the as-built frame shed presently in a nonconforming side yard location. The addition is proposed 13.4 feet from the southerly side lot line, and is proposed to be meet codes in all other respects for an accessory home office. ADDITIONAL INFORMATION: An as-built 8 x 10 shed that exists in a nonconforming side yard location will be relocated to a conforming location, as confirmed by the applicant's attorney letter received by the ZBA May 9, 2007, and its nonconforming location is not requested by applicant in this variance application. REASONS FOR BOARD ACTION: On the basis of testimony presented, materials submitted and personal inspections, the Board makes the following findings: 1. Grant of the variance will not produce an undesirable change in the character of the neighborhood or a detriment to nearby properties. The applicant's home has existed in this location for over 20 years. The applicant's driveway is located on the northeast corner of the property and the landscaping is extensive as Page 2- Susan Emanuele ZB File No. - 6036 CTM No. 106-8-20.4 established. The addition is based on the design of the dwelling and will be proportional at one-story, compared to the size and design of the existing dwelling. 2. The benefit sought by the applicant cannot be achieved by some method, feasible for the applicant to pursue, other than an area variance. A sanitary system and landscaped driveway areas are located in the front yard and in-ground swimming pool in the westerly yard. 3. The variance granted herein is not substantial. The reduction is 10% of the code requirement, for the requested 1.6 ft. setback reduction. 4. The difficulty has not been self-created. 5. No evidence has been submitted to suggest that a variance in this residential community will have an adverse impact on the physical or environmental conditions in the neighborhood. 6. Grant of the requested relief is the minimum action necessary and adequate to enable the applicant to enjoy the benefit of an addition, while preserving and protecting the character of the neighborhood and the health, safety and welfare of the community. RESOLUTION OF THE BOARD: In considering all of the above factors and applying the balancing test under New York Town Law 267-B, motion was offered by Member Goehringer, seconded by Member Oliva, and duly carried, to GRANT the variance as applied for, as shown on the April 13, 2007 survey prepared by Joseph A. Ingegno and the March 23, 2007 Construction Plan A-1 prepared by Richard Ebert. Any deviation from the variance given such as extensions, or demolitions which are not shown on the applicant's diagrams or survey site maps, are not authorized under this application when involving nonconformities under the zoning code. This action does not authorize or condone any current or future use, setback or other feature of the subject property that may violate the Zoning Code, other than such uses, setbacks and other features as are expressly addressed in this action. The Board reserves the right to substitute a similar design that is de minimis in nature for an alteration that does not increase the degree of nonconformity. Vote of the Board: Ayes: Members Dinizio (Chairman), Ol~iva,~Goehringer, and Simon. (Member Weisman was absent.) This Resolution was duly adopted (4-0). /'~ / Appro g TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL SOUTHOLD; NY 11971 TEL: 663'1) 765-1802 FAX: (631) 765-9502 www. north fork.net/Southold/ Examined .20 Approved Disapproved a/c Expiration PERMIT NO. BUILDING PERMIT APPLICATION CHECKLIST Do you have or need the following, before applying? Board of Heahh 4 sets of Building Plans Planning Board approval Survey Check Septic Form N Y S D. EC Trustees Contact: Building Inspector APPLICATION FOR BUILDING PERMIT Date .20 INSTRUCTIONS a This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 3 sets of plans, accurate plot plan to scale Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application, the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e. No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed ~vithin 18 months fi.om such date If no zoning amendments or other regulations affecting the propert3, have been enacted in the interim, the Building inspector may authorize, in writing, the extension of the permit for an addition six months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance ora Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County, New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances, building code, housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections J (S(g4~ature of applicant or name, if a corporatton) (Mailing address of al~licant) State whether app cant s owner essee, agent, arch tect cng neer, general contractor electrician, plumber or builder Name of owner of premises ffa.~/' ~t~U ~'Z ~" (As on the tax roll or latest deed) If applicant is a corporation, signature of duly' authorized officer (Name and title of corporate officer) Builders License No. Plumbers License No. Electricians License No. Other Trade's License No. I. Location of land on which I~'oposed work will be do~e: House Number Streel Hamlet Coun~ T= Map No. 1000 Section /~ Block ~, OO Lot O~O, ~ Subdivision Filed Map No. Lot (Name) 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy b. Intended use m~d occupancy 3. Nature of work (check which applicable): New Building Addition Repair Removal Demolition Other Work 4. Estimated Cost t,.~ ~t~, ~ Fee 5. I f dwelling, number of dwelling units If garage, number of cars Alteration (Description) (To be paid on filing this application) Number of dwelling units on each floor ~ 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front ~'~ p'~/" Rear ~'~ ~'1' Height '~, ~'"'r Number of Stories ~., Dimensions of same structure with alterations or additions: Front ~,~ pr'/. Depth ~' p~g' Height Z~ t~t~' Number of Stories 8. Dimensions of entire new construction: Front Rear Height Number of Stories 9. Size oflot: Front /~J~,~. ~f' Rear /~:~,~)~'/' Depth Depth Rear .Depth 10. Date of Purchase Name of Former Owner 11. Zone or use district in which premises are situated /t~-. ~ 12. Does proposed construction violate any zoning law, ordinance or regulation? YES /NO 13. Will lot be re-graded? YES / NO Will excess fill be removed from premises? YES 14. Names o f Owner o f p_remise~t~$at ~/.~IJ~F~ Address~ Y'~ ~.g Name of Architect ~" . Addres~Phone N o t~/-- Name of Contractor Address Phone No. 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO __ * IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERM1TS MAY BE REQUIRED. b. Is this property within 300 feet ora tidal wetland? * YES__ NO * 1F YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale, with accurate foundat on p an and distances to property lines. 17. If elevation at any point on property is at !0 feet or below, must provide topographical data on survey. STATE OF NEW YORK) SS: COUNTY OF ) m ,nuel*- being duly swom, deposes and says that (s)he is the applicant (Name of individual signing contract) above named, (S).e is the O~kJ ~ ~ ( (Contractor, Agent, Corporate Officer, etc.) of said o~vner or owners, and is duly authorized to perfom~ or have perfommd the said xvork and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in fl~e application filed therewith. REScheck Software Version 4.0.1 Compliance Certificate Project Title: Emanuele Residence Report Date: 07/30/07 Data filename: F:\\Emanuele.rck Energy Code: Location: Construction Type: Heating Type: Glazing Area Percentage: Heating Degree Days: Construction Site: 1585 Breakwater Road Mattituck, NY 11952 New York State Energy Conservation Construction Code Suffolk County, New York Detached 1 or 2 Family Non-Electric 16% 5750 OwnedAgent: Susan Emanuele 1585 Breakwater Road Mattituck, NY 11952 DesignedContractor: Richard Ebert P.E. RACE Drafting Inc. 8 Blair Drive Coram, NY 11727 631-476-1630 raceng@optonline.com Ceiling 1: Flat Ceiling or Scissor Truss: Ceiling 2: Cathedral Ceiling (no attic): Wall 1: Wood Frame, 16" Window 1: Vinyl Frame:Double Pane with Low-E: Floor 1: Ali-Wood Joist/Truss:Over Unconditioned Space: 424 30.0 0,0 15 48 19.0 0.0 2 576 15.0 0.0 37 9O O.320 29 472 19~0 0.0 22 The proposed building represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed systems have been designed to meet (he New York State Energy Conservation Construction Code requirements. When a Registered Design Professional has stamped and signed this page, they are attesting that to the best of his/her knowledge, belief, and professional judgment, such plans or specifications are in compliance with this Code. Richard Ebert P.E. - President Name - Title Signature Date DRAFT Emanuele Residence Page 1 of 1 FORM NO. 3 NOTICE OF DISAPPROVAL DATE: January 30, 2007 TO: Susan Emanuele 1585 Breakwater Rd. Mattituck, NY 11952 Please take notice that your application dated January 19, 2007 For permit to construct additions and alterations to an existing single family dwelling at Location of property 1585 Breakwater Rd., Mattituck County Tax Map No. 1000 - Section 106 Block8 Lot 20.4 Is returned herewith and disapproved on the following grounds: The proposed construction, on this non-conforming 39,640 square foot parcel in the R-40 District, is not permitted pursuant to Article XXIII Section 200-124, which states that non-conforming lots, measuring between 20,000 and 39,999 square feet in total size, require a minimum single side yard setback of 15 feet. Following the proposed construction, the dwelling will have a single side yard setback of 13.6 feet. Authorized Signature CC: file, Z.B.A Note to Applicant: Any change or deviation to the above referenced application may require additional review from the Southold Town Building Department. TOWN OF SOUTHOLD PROPERTY RECORD CARD OWNER STRE~r / ~¥;~_~ W,~GE D~ST. SUB. ,OT FQRMER OWNER N E ~ A~R. ~e((n ~% ~n)' S W ~PE OF BUILDING R~. -~_;; ~) S~S. VL. FARM CO~, CB. MI~. Mkt. Value ~ND IMP. TOTAL DATE R~RKS Tilloble FRONTAGE ON WATER W~l~nd FRONTAGE ON ROAD ~ DEPTH Ha Ma BULKH~D Total Porch Deck /,~ :l reez ewa' 3arage 2, ..~0 Foundation Basement Ext. Walls Fire Place Pool Patio Driveway _ ~ Bath Floors InteriorFinish Heat Attic Rooms 1st Floor Rooms 2nd Floor Erosion, Sedimentation & Storm Water Run off ASSESSMENT FORM PROPERTY LOCATION: S.C.T.M, #: THE FOLLOWING ACTIONS MAY REQUIRE THE SUBMISSION OF A /'~>~ /~ ~ (~ ~ fl-.~ STORM-WATER, GRADING, DRAINAGE AND EROSION CONTROL PLAN District Section Bl~ck ~ CERTIFIED BY A DESIGN PROFESSIONAL IN THE STATE OF NEW YORK. Item Number: 1 (NOTE: A Check Mark (~') for each Question is Required for a Complete Application) Will this Project Retain All Storm-Water Run-Off Generated by a Two (2") Inch Rainfall on Site? Ye~s N._~o (This item will include all run-off created by site clearing and/or construction activities as well as all Site Improvements and the permanent creation of impervious surfaces.) 2 Does the Site Plan and/or Survey Show All Proposed Drainage Structures Indicating Size & Location? This Item shall include all Proposed Grade Changes and Slopes Controlling Surface WaterFIow! 3 Will this Project Require any Land Filling, Grading or Excavation where there is a change to the Natural Existing Grade Involving more than 200 Cubic Yards of Material within any Parcel? 4 Will this Application Require Land Disturbing Activities Encompassing an Area in Excess of Five Thousand (5,000) Square Feet of Ground Surface? Is this Project within the Trustees jurisdiction or within One Hundred (100') feet of a Wetland or Beach? 6 Wiil there be Site preparation on Existing Grade Slopes which Exceed Fifteen (15) feet of Vertical Rise to One Hundred (100') of Horizontal Distance? 7 Will Driveways, Parking Areas or other Impervious Surfaces be Sloped to Direct Storm-Water Run-Off into and/or in the direction of a Town right-of-way? 8 Will this Project Require the Placement of Matedal, Removal of Vegetation and/or the Construction of any Item Within the Town Right-of-Way or Road Shoulder Area? (This item will NOT Include the Installation of Driveway Aprons.) 9 Will this Preject Require Site Preparation within the One Hundred (100) Year Floodplain of any Watercourse? NOTE: If Any Answer to Questions One through Nine is Answered with a Check Mark In the Box, a Storm-Water, Grading, Drainage & Erosion Control Plan is Required and Must be Submitted for Review Pdor to Issuance of Any Building PermiU EXEMPTION: Ye~s No Does this project meet the minimum standards for classification as an Agricultural Project? Note: If You Answered Yes to this Question, a Storm-Water, Grading, Drainage & Erosion Control Plan is NOT Required~ __ __ STATE OF NEWYORK,~7/L, It/, That I, ...-~..~7...~..~.~..~...........(-'r... ........... ~.~....~..~ ........... being duly sworn, deposes m,d says that he/she is flze apl,lictor, Ibr Pemfi,, (Na~ of individual signing ~u~nt) And that be/she is fl~e ...... ~.~.~Tg.~ ................................................................................................................... (O~er, Contra~or, Agent, Co~rate ~r, etc.) Owner an~or represent ttJ~ ~ of dz¢ O~)cr of Owner s, ;md is duly aud)orizcd to pcfform or have peEomzed d~e s;dd work m)d to m;~¢ ;md ~1~ dfis application; that MI statcmcn~ contained m tbJs appl[caQon arc true to the best o[ his k~ow]¢dge and b¢lJ¢[; that tbe work ~11 be pcEom)ed in the m;umcr sct [o~h m fl~c application filed b¢rcwitb. Sworn to before nle this; ...................... ................. d;ty ..................... Not~ Oualified in Suffolk Coun~ FORM - 06/07 ~'ommission Expires November 19, 'S-S s ~S 0 CL PROPOSED ~ RST FLOOR PLAN PROPO$[B REAR ELEVATION P~(JPOSED 5 DE ELE~,ATION P~OPOSED FRONT ELEVATION F:\EmanueI.DWG, 1/13/2007 5:09:24 PM, RACE Drafting Inc. STANLEY ROAD 200'00' SURVEY OF PROPERTY SITUATED AT MATTITUCK TOWN OF SOUTHOLD SUFFOLK COUNTY, NEW YORK TAX No. 1000-106-08-20.4 SCALE 1"--20' APRIL 15, 2007 AREA 40,000.48 sq. ft. 0.918 ac. CERTIFIED TO; SUSAN EMANUELE N.Y.S. Lic No. 49668 Jose Ingegno Surveyor 27-101 RETAIN STORM WATER RUNOFF PROPOSED ALTERATION5 TO: EMANUEL RESIDENCE REScheck Software Version 4.0.1 Compliance Certificate Project Ti[lel Em~hu'~l~ Residence Repot' Date: 08/16/07 Data filename; F;/IEmanuele rck Energy Code, New York State Energy Conservation Construction Code Location Suffolk County, New York Censtrucllon Type, Detached 1 or 2 Family Fleahng Type Non-Electric Glazing Area Percentage, 1§% Heating Degree Days: 5750 Construction Site' 1585 Breakwater Read Mattltuck, NY 11952 Owner/Agent' 1585 Breakwater Road Mattltuck, NY 11952 DemgnedContractor Richard Ebed RACE Drafting In¢ 8 Blair Drive Coram, NY 11727 CoRing 1. Flat Ceiling or Scissor Truss Cmhng 2 Cathedral CoRing (no atllc) Wall 1 Wood Frame, 16" Window 1 Vinyl Frame Double Pane with Low-E, 424 300 0,0 15 48 190 00 2 576 15,0 00 37 90 0 320 29 472 19 O 0 O 22 TABLE 3,1 NAILING BCHEDULE lAM HOOD FRAME CONSTRL~TION MANUAL (NFCM) ONE ~; TMO-FA~llLT DNELLI~5, FOP PLATE TO TO~ P[c~T[ [ JOINTS -FACq OlDE PEN 5TUP PER FC~DT FLOOR FP. AMINq qYpSUM ~A~ B~ARp EAq4 PER E~2r , OF A LENGTH TO PENETRATE THROUGH THE ROOFING MATERIALS AND 15 IN ONE ~ THE FOLLONING CATE~RIES - DESIGN LOADS lAN MOOD FRAME CONSTRUCTION MANUAL (NFCM) ONE J THO-FAMILY [)MELLINGS~ 2001 ~IND LOADS lAN MOOD FRAME CONSTRUCTION MANUAL (HFCM) ONE ¢ TNO-FAMILT ONELLINGS, 1~¢3 5SC NIGH HIND EDITION LIVE LOAD !DEAO LOAD AUZ~CJ~.E DEFL[CTI~ LIVING AREA5 40.0 ps¢ IO.O ps[' L/~GO SLEEPING AREAS 50.O psF IO.O ps~' L/~GO ATTIC 20.0 psF 5.O ps¢ L/240 ROOF 50.0 p5¢ IO.O p5¢ L/240 MALL ~5.0 ~f L/120 5NON 50 psF G~OUND SEISMIC CAT. C ~IN~ I10 mph ~5B Emanuele Residence Page I of 1 GROUND ~ MIND LOAD J 5PEEl) (mph)J CRITERIA 45 POFI 120 MPN I B TABLE R501.2,1 CLIrlATIC AND GEOGRAPHIC DESIGN CRITERIA SUBJECT TO DAMAGE FROM t4LNTER ICE SWIELD I FROST LINE T~RMITE DESIGN UNDERLAYMENTI FLOOD NEATHERING PEFTR DECAY T~P ~EeP H~AR~ SEVERE ~'-0" ~g-H~ 5LI~T-~D REQU ~ED SEE P~N5 EXST DRAINING LIST T-I TITLE SHEET GN-I GENERAL NOTES A-I PROPOSED FOUNDATION PLAN A-2 PROPOSED FIRST FLOOR PLAN A-3 PROPOSED BUILDING SECTION* AND A-4 PROPOSED EXTERIOR ELEVATION5 DETAtL5 lB/eT P~JDR NEH BATH PLUMBING TIE INTO EXIST APPROVED SUFFOLK SCHEMATIC RICHARD EBERT ,No. i Revie, ion/l~eue Dat. ej ENGINEERING. DE81I~I. DRAFI'F~ h- Z NIT 50 O0 E OF THE TOWN CODE Iq3.2q~ STY ADDTN 517°50'ooJ~J,~ 52.G2 - ',. L CODES OF NE~A'. "' 5 :,' - t TOWN CODES ASRL :E.,, ~. , .C,~DiTIONSOF EX'BT POOL -- EXST DECK EXST 2 STY DIqELL 23.8, r . OCCUPANCY OR USE IS UNLAWFUL W!! HOUT CERTIFICATE OF 3 CCUPANCY Lot Area AP,PROyED AS NOT[2 765.1802 BAH TO 4~M FOR THE ~OLLOWING INSPECTIONS: % FOUNgATION. TW¢ REQUIRED FO~ POU~ED CONCRETE 2. ROUGH - FRALfiNG &' PLdJ¢3,NG & INSULATION 4. F?NAL . COH¢~m leTlr~N MUST BE COMPLE~ FOR C,O, ~&L CONSTRUCTION SH*LL MEET THE RE 'J,IREMENT8 ~FT~ECO~ESOFNEW YORK STATE, NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. = 40000 Exisitincj Residence Proposed Addition = Existincj Deck = 5q4 CERTIFICATION OF NAILING & CONNECTI,ONS RE.QU RED. ALL CONSTRUCTION SHALL ~EET THE REQUIREMENTS OF THE " E CODES OF N~W YORK STAT . scl Ft = IC~q2 scL Ct 472 sc~ Ft [ UNDERWRITERS CERTIFICA'~ REGUJBEO PLUMBING ALL pLOMBING WASTE & WATER LINES NEED EFORE cOVERING ,TEST NG B .... PLUMBER CERTIFICATION ON LEAD CONTENT BEFORE cERTIFICATE OF OCCUPANCY ~A~V r)r ~: ~ , ::ED ,~l t,t/gTFR S,~"' ;' " "(" ' q' v 5' ~,~'C . C, ;',,: LEAD. .__~~6.40 " ~ - ~" ~"'-'"-'""'"'-~.~4 I BREAK!XATER ROAD NOTE: INFORMATION PLOT PLAN BASED ON SURVEY PROVIDED BY ONNER MIND-BORNE DEBRIS PROTECTION FASTENING SCHEDULE FOR ~OOD BTRUCURAL PANELS FASTENER SPACING 'PANEL SPAN" ~pANEL SPAN~ "PANEL 5PAN" FASTENER LEO5 THAN GREATER THAN AFT GREATER THAN 6FT TYPE OR EQUAL LES5 THAN LES5 THAN TO 4FT OR EQ TO OFT OR E9 TO 8FT 2-1/2" ~6 HOOD 5CREN5 IGII aC 12" ~ 12" ~ I. MOOD STRUCTURAL PANELS SHALL BE ~" MIN THICKNESS. 2, PANELS SHALL BE CONSTRUCTED PROM EXTERIOR GRADE~ CDX PLT~JOOD. 3, PANELS SHALL BE PRECUT TO COVER GLAZED OPENINGS ~!ITH ATTACHMENT HDM PROVIDED. 4. DRILL FOUR ~4j' HOLES IN CENTER AREA OF PANEL AB PRESSURE RELIEF PORT DURING HURRICANE. 5. PANELS 5HALL ~E CLEARL~ MARKED TO EACH MINDOM ¢ GLAO~ ~ FO~ RAPID INSTALLATION. 6. PANEL~ 5HALL BE 5TARED ON-~ITE. 7. FOR GLASS D~R OPENINGS LARGE~ THAN ONE 4~X8' 5HE~ OF PLTN~D~ (2)-2~X4" BRACING ~HALL ~E ATTACHED IN T~E MIDDLE AND ~OM¢ EQUALLY ~PACED. I~INDOIN pROTECTION FOR NIND-BORNE DEBRIS REGION **NOTE: ALL ININDOPAS SHALL BE ANDERSEN ININDO~ SERIES 400 OR EQUIVALENT EMANUEL RESIDENCE 15&5 BREAI% ATER ROAD MATTITUCK/ N.Y. Iiq52 ,(PROPOSED ONE STY ADDITION) AUGUST I~I 2007 ti4"-- I'-0" THESE P~N5 HAVE BEEN DESIGNED IN ACCORDANCE ~ITH THE ~CHARD EBERT ill~N°. R~vie'i°n/15sue Dat~li~ EMANUELE RESIDENCE 158~5 BREAI(.IMATEP-. ROAD PJATTITUCt<;, N."K. 11q52 (('PROPOSED ONE STY ADDITION) AUGUST 2007 1/411=ll-OII DROP TOP OF FND TO MATCH FXST (VERtF~ kiT IN FIELD.) .... II Im ";-" '~ I REMOVE ~XST BASEMENT-,, FI ~ ~ J F-- ] I BASEMENT I L__J I I__L--J I r-~ r-a r-n I~ ------ i I L_J L_J L_J ~l[~ ~ ~ TE~ ~ I FRN El MIL VA~ ~RIER -- j '" I I . ~ ~T ~L~P I I ~ N/ EPO~ FILLER I I ~/ (TTP2PL) I I ' ~T - I GARAGE I I I I I I I I I I I I Lr~ ANCHOR BOLT SPECIFICATION O~ PROPOSED FOUNDATION PLAN I/4"=1~-0'j FIRST FLOOR CORNER HOLD DONNS RICHARD EBERT i~ ~,~No. Revision/Issue Date/i~ EPflANUELE RESIDENCE 15&5 BREAKINATER ROAD P1ATTITUCK/ N.Y. 11q52 (PROPOSED ONE STY ADDITION,) AUGUST I~b 2007 I/4"=1'-0~ i1¸ I~%IO.l,I, I'IlNII-1UM OPENING Ai~EA. ALL EI4ERGENC¥ E~]APE AND RESC~UE OpENiNGS 5HALL HAVE A HiNIHUI'I NET CLEAR OpENIkI~ OF E.? ~UA~E FEET, EXCEPT{ON GRADE FLOOR OPENINGS .~-IALL HAVE A MINIr'IUH NET CLEAR .,4q'-.4ir (2)-2"X1¢ (2)-£NI45 121-4" NEN HOME GTm SDo ~ NEIN _~._~ATH NEN HALLNAT CL 5OC CL f CL EXST DINING ROOM EXST RIDGE EXST ? (2)-Z'XU" 'D~ rO EXST KITCHEN LIVING ROOf'd 24'-O" (3)-CLNI45 7'_81r CTCFII PROPOSED KIP. ST FLOOR NEJN ADDrTION = 460 5Q FT PLAN 1M"=I'-O" (WF) SD O co [] EXISTING CONTE[UCTION TO BE REMOVED NEW CONSTRUCTION EXISTING CONSTRUCTION VERIFT IN FIELD INDICATES HARDNIRED INTER~NNECTED 5HOKE DETECTOR INDICATE~ HA~D~IRED INTERCONNECTED CARBON MONOXIDE D~ECTOR EXST '~ DEN ~ PNDR CL CL 24'-4" EXST GARAGE LNDR¥ m RICHARD EBERT No. Revision/Issue Date~ EMANUELE RESIDENCE 1565 BREAKIAIATER ROAD FiATTITUCK/ N.Y. Iiq52 ('PROPOSED ONE STY ADDITION) AUGUST I(~, 2007 I/4"= II-On ROOF~ ASPHALT ROOF SHINGLES (SELF SEALING) RIDGE 2"XIO" 30~ BLDG V/N- iE :~" EXT PLY 2"X4" RIDGE :2"XIO" 2"X~" RR @If" DC CT 12 ;E T~ ~ ~ ~(2)-2"X4" MEN MEN ) 4~l P.CONC ~LA~ [~ HIL VAPOR BARRIOR EXPANDED /CLEAN CO~PACT FILL ~ BASEH~ , -I ICE SNIELD~ PROVIDE SNOIN ¢ ICE SHIELD FROM OUTSIDE EDGE OF ROOF PROJECTING ONTO ROOF 24 FROM INSIDE FACE OF EXTERIOR MALL TYP SILL~ (2)-2"X~," CCA TERMITE 5HLD SILL ~EALER ANCHOR BOLT9 GRADE PROVIDE MATE PR~FING (~EE GENERAL NOTE~ FOR ~PEC 3~-0" DEEP MIN~ P.CONC FOUNDATION MALL ON I~" ~IDE X 6" NIGH P.CONC. FTG M/ 2"X4" f (2)-~5 REBAR SECTION A-A I/4"=1'- 0" ' ~) = LOAD PATH ROOF, ASPHALT ROOF SFIINGLES (SELF SEALING) BLDG FELT ~" EXT PLY 2"X8" RR @16" DC HALLS: VERTICAL CEDAR SIDING (MATCH EXST) ROSIN PAPER EXT PLY @1~," O.C. R-15 INSULA'T~ON FLOORS: FLOOR AS SELECTED BY 4~'' PLY SCREMED ~ GLUED TO 2"XI0" FJ ~16" (~ATCP EXST FL HT) RAPE 235' ~ FIE~E~C_.i$_A~ ,.~4.4+NGLES ON 30~ BLDG FELT ON I/2" EXT PLY R-IR INSULATION .~NOIN ¢ ICE ~NLD 2"X8" RR @IC~"OC VENTED $OFIT TYP INALL EAVE ROOF I/2" GNB 2"X4" ~TUD.5 @IloII N/R-15 I N..~UL DETAIL RAFTER 5~UNDERLAYMENT CARRIED UP ONTO SIDENALL ~" TO 4" NAIL FLASHING TO ROOF NITN 2 NAILS ROOFING CEMENT STEP FLA.C>NING POSITIONED OVER SHINGLE 50 THAT NEXT COURSE OF .SHINGLE5 COVERS IT COMPLETELT SIDING SERVES AS COUNTER-FLASI41NG OVER STEP FLASHING STEP FLASNING ON SIDENALL N.T,S. JOIST DEPTH MAX. ~, JOIST EPTN MAX 2" MIN JOIST DEPTN mAX OA-, JOIST DEPTH ~OLE MAX OUTER ~ OF SPAN ONLY PLATE. EDGE DIST >~ -STUD HOLE EDGE DIST ) ~' DEPTN( ~d HOLE DIA ( ~d 'SINGLE STUD.) HOLE PlA < ~d 'DOUBLE STUD) JOIST NOTCN ING P-.AFTEIE BORING LIiNTS N.T,S. NOTCPt lNG- STUD 4; BO~ING Lll"ITS 12" ROOF: LG MIN END LENGTH (T'r'P) /-RIDGE VENT 23"5:~ ASPNAL~- I(~ GA GALV STL STRAP / ' P,I/ 4-10D COMMON NAJLS-~ / EXST ~O~[F SHINGLE5 @EA ROOF RAFTER X //2"XlO" RIDGE ~. ~ /~ XT PLY RIDGE DETAIL UPLIFT CONNECTION FND-SILL PLATE TO MALL: UPLIFT CONNECTION I]4" X 20 GA GALV STL STRAP IN/ -'5-~5d COI'IMOM NAILS EA END @16" C~; OR AT EA STUD LAP STRAP UNDER BOTTOM OF SILL ¢ NAIL I/2"= I'-0" I~ir X 20 GA GALV STL STRAP NRAP OVER JOIST M/ 3-&d COMt"IOi"I NAILS} AT EA STUD ¢ RAFTER\ (OPTiONAL:SIf'IPSO~ N2 STRAP SMONN)% 2"X&" RR @1~" ROOF TO MALL UPLIFT CONNECTION N,T.S, "SIMPSOW~ LSTA SERIES STRAPPING AS SNONN' OR AT EACH CRIPPLE 5TUB "SIMP.~DN" LSTA SERIES STRAPPING AT EACH JACK AND KING STUD FND-.SILL UPLIFT PLATE TO !NALL CONNECTION N.T.~,. "SIMPSON" LSTA SERIES STRAPPING AT EAC~ JACK AND KING STUD l,q I N DO~N ¢ DOOR PLEADER CONNECTION N.T.S. R/CHARD EBERT ETNANUEL RESIDENCE 1565 BREAK!AIATER ROAD MATTITUCK, N.Y. Ilq52 (PROPOSED ONE STY ADDITION.) AUGUST l~/ 2007 I/4"=ILO'' II I PROPOSED ~IDE ELEVAT ION PROPOSE[} ADDITION PROPOSED ADDITION PROPOSED ADDITION PROPOSED ADDITION PROPOSED REAR ELEVATION PROPOSED FRONT ELEVATION l/4"=ll-OI~ RICHARD EBERT No. Revision/Issue DoL~ EI"IANUELE RESIDENCE 1158,5 BREAK!NATER ROAD I'flATTITUCK, N.'Y. 11q52 ('PROPOSED ONE STY ADDITION) AUGU,$T 1~,I 2007 I/4"=1'-0"