Loading...
HomeMy WebLinkAbout32492-ZFORM NO. 4 TOWN OF SOUTHOLD BUILDING DEPARTMENT office of the Building Inspector Town Hall Southold, N.Y. CERTIFICATE OF OCCUPANCY No: Z-33197 Date: 09/10/08 THIS u~KTIFIES that the building ADDITION Location of Property: 1850 JOCKEY CREEK DR (HOUSE NO.) County Tax Map NO. 473889 Section 70 subdivision SOUTHOLD (STREET) {HAMLET) Block 5 Lot 20 Filed Map No. LOt No. conforms substantially to the Application for Building Permit heretofore filed in this office dated NOVEMBER 14, 2006 pursuant to which Building Permit No. 32492-Z dated NOVEMBER 15, 2006 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is ADDITION TO AN EXISTING ONE FAMILY DWELLING AS APPLIED FOR. The certificate is issued to MARY E DOOL~kN of the aforesaid building. (OWNER) SUFFOLK COUI~Y DEPARTMENT OF HEALTH APPROVAL RLRt-rKICAL C~K'rIFICATH NO. PLUI~ERS CERTIFICATION DA-r~ 08/31/08 2019601 HARDY PLUMBING 07/25/08 ~~hOrize~ Rev. 1/81 DCT-22-2006 19:37 FROM: T0:2981128 P.4 l%rm No. 6 ~OVqN OF $OUTHOLD BUIlDInG DEPARTMENT TOWN HALL 765-1802 House No, Street -- ~' Har~lct Owner or Owners of Property: Suffolk County Tax Map No 1000, S~tion 070 Subdivision ~q% H~lth Dept. Approval: Pla~ing Board Approval: g~uest for: Tempora~ Certificate Fee Submitted: $ Block 'i Filed Map. [ Date ofl~ennit. ~ Applicant:_ Underwriters Appro~a Final Certificate: Lot __~.O Lot: (check one) Applicant Signature APPLICATION FOR CERTIFICATE OF OC( IJPANCY This application must be filled in by typewriter or ink and submitted to the Build ag Department with the following: A. For new building or new use: i 1. Fblal survey of property with accurate location of all buildings, property~|ines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and scwemge-disposa' (SL9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system; ontains less than 2/10 of 1% lead. 5. Commercial building, industrial building, multiple residences and similm buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the build ag. 6~ Submit Planning Board Approval of completed site plan rcqukements. , B. For existing huildings (prior to April 9, 1957) uon-conforming uses, or h~ildings and pre-existing land us : I. Accurate survey of' property showing all property lines, streets, building )nd nnusual natural or topographic features. / 2. A properly completed application and consent to inspect signed by the al plicant. If a Certificate of Occupancy is denied, the Building hlspcctor shall state the reasons therefor in writing ~ ~ the applicant. C. Fees l. Certificate of Occupancy - New dwelling $25.00, Additions to dwelling ;25.00, Alterations to dwelling $25.00, Swimming pool $25.00, Accessory building $25.00, Additions to access ~ry building $25.00, Businesses $50.00. 2. Certificate of Occupancy on Pre-existing Building - $100.00 ' 3. Copy of Certificate of Occupancy- $,25 4. Updated CertificateofOccupm~cy- $50.00 5. Temporary Certificate of Occupancy - Residential $15.00, Commercial 15~00 Oate. t3.6 .og New Construction: Old or Pre-existing Building: ~ ! (check one) BY THIS CERTIFICATE OF COMPLIANCE THE NEW YORK BOARD OF FIRE UNDERWRITERS BUREAU OF ELECTRICITY 40 FULTON STREET ~ NEW YORK, NY 10038 CERTIFIES THAT Upon the application of upon premises owned by G & S ELECTRICAL CONTR, TOM DOOLAN P,O, BOX 215 1850 JOCKEY CREEK DRIVE SOUTHOLD, NY 11971, SOUTHOLD, NY 11971 Located at 1850 JOCKEY CREEK DRIVE SOUTHOLD, NY 11971 Certificate Number: Application Number: 2019601 2019601 Section: Block: Lot: Building Permit: 0 BDC: NS11 Described as a Residential occupancy, wherein the premises electrical system consisting of electrical devices and wiring, described below, located in/on the premises at: Second Floor, A visual inspection of the premises electrical system, limited to electrical devices and wiring to the extent detailed herein, was conducted in accordance with the requirements of the applicable code and/or standard promulgated by the State of New York, Department of State Code Enforcement and Administration, or other authority having jurisdiction, and found to be in compliance therewith on the 2Sth Day of July, 2oo8. Name OTY Rate Ratine Circuits Twe AdditionalCharges finnished room above garage Appliances and Accessories Electrical Heat Unit I 0 I KVV Wiring And Devices Fixture 8 0 Incandescent Outlet 8 0 Fbxture Outlet 9 0 Gen, Purpose ReceptacJe 5 0 Gert, Purpose Switch 8 0 Gen. Purpose seal 1 of 1 This certificate may not be altered in any way and is validated only by the presence of a raised seal at the location indicated. TOWN OF SOUTHOr.I~ OFFICe- OF BUlLDII,IS INSPECrOR P.O. DO;: 128 TOWN I.L°.LL 8OUTHOLD, N.Y. 11971 . T,EL. 765-1802 CERTIFICATION Date I certify tha'c the solder used in the water contains less than 2'/10 of 1% lead. supply system 'Sworn ~o before me =his .Fl d- Nota:'~ Publi=, '' ' (plumber's 4gnature) EILEEN STRAND NOTARY PUBLIC, Stere o! New ~ No. O1 ST6001493 Oualified in Suffolk Cou~t~ Commission Expires January 12, 207/ FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. (THIS BUILDING PERMIT PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 32492 Z Date NOVEMBER 15, 2006 Permission is hereby granted to: MARY E DOOLAN 1850 JOCKEY CREEK DR SOUTHOLD,NY 11971 for : SECOND STORY ADDITION OVER EXISTING ATTATCHED GARAGE AS APPLIED PER DEC W/FLOOD PERMIT AS REQUIRED.REPLACES BP# 30397 at premises located at County Tax Map No. 473889 Section 070 pursuant to application dated NOVEMBER Building Inspector to expire on MAY 1850 JOCKEY CREEK DR SOUTHOLD Block 0005 Lot No. 020 14, 2006 and approved by the 15, 2008. Fee $ 250.00 Aut h6~i~ed Signature ORIGINAL Rev. 5/8/02 FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 30397 Z Date JUNE 15, 2004 Permission is hereby granted to: MARY E DOOLAN 1850 JOCKEY CREEK DR SOUTHOLD,NY 11971 for : SECOND STORY ADDITION OVER AN EXISTING ATTACHED GD~RAGE AS APPLIED FOR PER DEC W/ FLOOD PERMIT AS REQUIRED at premises located at County Tax Map No. 473889 Section 070 pursuant to application dated JUNE Building Inspector to e~ire on DECEMBER 1850 JOCKEY CREEK DR SOUTHOLD Block 0005 Lot No. 020 8, 2004 and approved by the 15, 2005. Fee $ 250.00 ORIGINAL Rev. 5/8/02 New York State Department of Environmental Conservation Division of Environmental Permits Building 40 - SUNY, Stony Brook, NY 11790-2356 Telephone (631) ~.~.~.-0365 Facsimile (631) ~.~.5-0360 Website: www.dec.state.ny.us Erin M. Crotty Commissioner May 6, 2004 Mr. Thomas Doolan 1850 Jockey Creek Drive Southold, NY 11971' RE: 1-4738-03277/00001 Dear Permittee: In conformance with the requirements of the State Uniform Procedures Act (Article 70, ECL) and its implementing regulations (6NYCRR, Part 621) we are enclosing your permit. Please read all conditions carefully. If you are unable to comply with any conditions, please contact us at the above add/ess. Also enclosed is a permit sign which is to be conspicuously posted at the project site and protected from the weather. Sincerely, Claire K. Wemer Environmental Analyst CKW/ls NEW YORK STATE DEPARTMENT OF ENVIRONMENTAL CONSERVATION DEC PERMIT NUMBER J 1-4738-03277/00001 I ~ FACILITY/PROGRAM NUMBER(S) I ~ PERM IT I Under the Environmental Conservation Law EFFECTIVE DATE May 6,2004 EXPIRATION DATE(S) May6,2009 TYPE OF PERMIT · New [] Renewal [] Modification · Permit to Construct [] Permit to Operate [] Article 15, Title 5: Protection of Waters [] Article 15, Title 16: Water Supply [] Article 15, Title 15: Water Transport [3 Article 15, Title 15: Long Island Wells [3 Article 15, Title 27: Wild, Scenic and Recreational Rivers [] 6NYCRR 608: Water Quality Certifica- tion PERMIT ISSUED TO [] Article 17, Titles 7, 8: SPDES [] Article 19: Air Pollution Control [] Article 23, Title 27: Mined Land Reclamation [] Article 24: Freshwater Wetlands · Article 25: Tidal Wetlands [3 Article 27, Title 7; 6NYCRR 360: Solid Waste Mana~lement Thomas Doolan ADDRESS OF PERk~ ~ ~ cE 1850 Jockey Creek Drive, Southold, NY 11971 [] Article 27, Title 9; 6NYCRR 373: Hazardous Waste Management Article 34: Coastal Erosion Management [] Article 36: Floodplain Management [] Articles 1, 3, 17, 19, 27, 37; 6NYCRR 380: Radiation Control ITELEPHONE NUMBER (631) 765-4073 CONTACT PERSON FOR PERMITTED WORK Frank Notaro, Architechnolo~lies, 13405 Main Road, Mattituck, NY 11952 NAME AND ADDRESS OF PROJECT/FACILITY Doolan property, 1850 Jockey Creek Drive, Southold SCTM #1000-70-5-20 ITELEPHONE NUMBER (631)298-1129 COUNTY Suffolk TOWN I WATERCOURSE Southold Jockey Creek DESCRIPTION OF AUTHORIZED ACTIVITY: Construct second story addition over existing garage. attached plans stamped NYSDEC approved on 5~6/04. INYTM COORDINATES All work must be done in accordance with the By acceptance of this permit, the permittee agrees that the permit is contingent upon strict compliance with the ECL, all applicable regulations,, the General Conditions specified (see page 2 & 3) and any Special Conditions included as part of this permit. PERMIT ADMINISTRATOR: Mark C. Carrara (CKW) AUTHORIZED SIGNATURE IADDRESS Region 1 Headquarters, BId~. g40, SUNY, Stony Brook, NY 11790-2356 May 6, 2004 Page 1 of 4 NEW YORK STATE D EPAR'I~IENT OF ENVIRONMENTAL CONSERVATION SPECIAL CONDITIONS 1. Any debris or excess material from construction of this project shall be completely removed from the adjacent area (upland) and removed to an approved upland area for disposal. No debris is permitted in tidal wetlands and or protected buffer areas. 2. The storage of construction equipment and materials shall be confined to landward of the existing house. 3. Necessary erosion control measures i.e., haybales, silt fencing, etc. are to be placed on the downslope edge of any disturbed area. This sediment barrier is to be put in place before any disturbance of the ground occurs and is to be maintained in good condition until thick vegetative cover is established. 4. Roof runoff shall be direCted to drywells a minimum of 100 feet landward of the tidal wetland boundary for immediate on-site recharge. 5. This permit does not authorize any alteration, expansion or replacement of existing septic systems. DEC PERMIT NUMBER 1-4738-03277/00001 PAGE 2 of 4 NEW YORK STATE D EPAR'~,tENT OF ENVIRONMENTAL CONSERVATION ADDITIONAL GENERAL CONDITIONS FOR ARTICLES 15 (TITLE 5), 24, 25, 34 AND 6NYCRR PART 608 ( TIDAL WETLANDS) If futura operations by the State of New York raquira an alteration in the position of the structure or work herain authorized, or if, in the opinion of the Department of Environmental Conservation it shall cause unraasonable obstruction to the free navigation of said waters or flood flows or endanger the health, safety or welfara of the people of the State, or cause loss or destruction of the natural resources of the State, the owner may be orderad by the Department to remove or alter the structural work, obstructions, or hazards caused theraby without expense to the State, and if, upon the expiration or ravocation of this permit, the structure, fill, excavation, or other modification of the watercourse heraby authorized shall not be completed, the owners, shall, without expense to the S. tate, and to such extent and in such time and manner as the Department of Environmental Conservation may raqu~re, remove all or any portion of the uncompleted structura or fill and rastora to its former condition the navigable and flood capacity of the watercourse. No claim shall be made against the State of New York on account of any such removal or alteration. The State of New York shall in no case be liable for any damage or injury to the structura or work herein authorized which may be caused by or rasult from futura operations undertaken by the State for the conservation or improvement of navigation, or for other purposes, and no claim or right to compensation shall accrue from any such damage. Granting of this permit does not relieve 'the applicant of the rasponsibility of obtaining any other permission, consent or approval from the U.S. Army Corps of Engineers, U.S. Coast Guard, New York State Office of General Services or local government which may be required. 4. All necessary precautions shall be taken to preclude contamination of any wetland or waterway by suspended solids, sediments, fuels, solvents, lubricants, epoxy coatings, paints, concrete, leachate or any other environmentally deleterious materials associated with the project. 5. Any material dredged in the conduct of the work herein permitted shall be removed evenly, without leaving large refuse piles, ridges across the bed of a waterway or floodplain or deep holes that may have a tendency to cause damage to navigable channels or to the banks of a waterway. 6. There shall be no unreasonable interference with navigation by the work herein authorized. If upon the expiration or revocation of this permit, the project hereby authorized has not been completed, the applicant shall, without expense to the State, and to such extent and in such time and manner as the Department of Environmental Conservation may raquira, ramove all or any portion of the uncompleted structure or fill and rastore the site to its former condition. No claim shall be made against the State of New York on account of any such removal or alteration. If granted under 6NYCRR Part 608, the NYS Department of Environmental Conservation hereby certifies that the subject project will not contravene effluent limitations or other limitations or standards under Sections 301,302, 303,306 and 307 of the Clean Water Act of 1977 (PL 95-217) provided that all of the conditions listed herein are met. 9. At least 48 hours prior to commencement of the project, the permittee and contractor shall sign and return the top portion of the enclosed notification form certifying that they are fully aware of and understand all terms and conditions of this permit. Within 30 days of completion of project, the bottom portion of the form must also be signed and raturned, along with photographs of the completed work and, if raquirad, a survey. 10. All activities authorized by this permit must be in stdct conformance with the approved plans submitted by the applicant or his agent as part of the permit application. Such approved plan was oraoared by John T. Melz,qer dated 9/9/03, DEC PERMIT NUMBER 1-4738-03277/00001 IPAGE 3 Of 4 NEW YORK STATE DEPARTMENT OF ENVIRONMENTAL CONSERVATION NOTIFICATION OF OTHER PERMITTEE OBLIGATIONS Item A: Permittee Accepts Legal Responsibility and Agrees to Indemnification The permittee expressly agrees to indemnify and hold harmless the Department of Environmental Conservation of the State of New York, its representatives, employees, and agents ("DEC") for all claims, suits, actions, and damages, to the extent attributable to the permittee's acts or omissions in connection with the permittee's undertaking of activities in connection with, or operation and maintenance of, the facility or facilities authorized by the permit whether in compliance or not in compliance with the terms and conditions of the permit. This indemnification does not extend to any claims, suits, actions, or damages to the extent attributable to DEC's own negligent or intentional acts or omissions, or to any claims, suits, or actions naming the DEC and arising under article 78 of the New York Civil Practice Laws and Rules or any citizen suit or civil rights provision under federal or state laws. Item B: Permlttee's Contractors to Comply with Permit The permittee is responsible for informing its independent contractors, employees, agents and assigns of their responsibility to comply with this permit, including all special conditions while acting as the permittee's agent with respect to the permitted activities, and such persons shall be subject to the same sanctions for violations of the Environmental Conservation Law as those prescribed for the permittee. Item C: Permittee Responsible for Obtaining Other Required Permits The permittee is responsible for obtaining any other permits, approvals, lands, easements and rights-of-way that may be required to carry out the activities that ara authorized by this permit. Item D: No Right to Trespass or Interfere with Riparian Rights This perm'it does not convey to the permittee any right to trespass upon the lands or interfere with the riparian dghts of others in order to perform the permitted work nor does it authorize the impairment of any rights, title, or interest in real or personal property held or vested in a person not a party to the permit. GENERAL CONDITIONS General Condition t: Facility Inspection by the Department The permitted site or facility, including relevant records, is subject to inspection at reasonable hours and intervals by an authorized representative of the Department of Environmental Conservation (the Department) to determine whether the permittee is complying with this permit and the ECL. Such representative may order the work suspended pursuant to ECL 71-0301 and SAPA 401(3). The permittee shall provide a person to accompany the Department's representative during an inspection to the permit area when requested by the Department. ' A copy of this permit, including all referenced maps, drawings and special conditions, must be available for inspection by the Department at all times at the project site or facility. Failure to produce a copy of the permit upon request by a Department representative is a violation of this permit. General Condition 2: Relationship of this Permit to Other Department Orders and Determinations Unless expressly provided for by the Department, issuance of this permit does not modify, supersede or rescind any order or determination previously issued by the Department or any of the terms, conditions or requirements contained in such order or determination. General Condition 3: Applications for Permit Renewals or Modifications The permittee must submit a separate written application to the Department for renewal, modification or transfer of this ~ermit. Such application must include any forms or supplemental information the Department requires. Any renewal, modification or transfer granted by the Department must be in writing. The permittee must submit a renewal application at least: a) 180 days before expiration of permits for State Pollutan~ Discharge Elimination System (SPDES), Hazardous Waste Management Facilities (HWMF), major Air Pollution Control (APC) and Solid Waste Management Facilities (SWMF); and b) 30 days before expiration of all other permit types. Submission of applications for permit renewal or modification are to be submitted to: NYSDEC Regional Permit Administrator, Region 1, SUNY Bldg #40, Stony Brook NY 11790-2356 General Condition 4: Permit Modifications, Suspensions and Revocations by the Department The Department reserves the right to modify, suspend or revoke this permit in accordance with 6 NYCRR Part 621. The grounds for modificetion, suspension or revocetion include: a) materially false or inaccurate statements in the permit application or supporting papers; b) failure by the permittee to comply with any terms or conditions of the permit; c) exceeding the scope of the project as described in the permit application; d) newly discovered material information or a material change in environmental conditions, relevant technology or applicable law or regulations since the issuance of the existing permit; e) noncompliance with previously issued permit conditions, orders of the commissioner, any provisions of the Environmental Conservation Law or regulations of the Department related to the permitted activity. DECPERMITNUMBER I I PAGE 4 OF 4 1-4738-03277/00001 TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ]FOUNDATION 1ST [ ]FOUNDATION 2ND [ ]FRAMING / STRAPPING [ ]FIREPLACE & CHIMNEY [ ]FIRE RESISTANT CONSTRUCTION [ ] ROUGH PLBG. [ ] INSULATION [~FINAL [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTAI~I' PENETRATION DATE INSPECTOR~~ TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] I~I~LATION [ ] FRAMING / STRAPPING [ ~] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION DATE ~ INSPECTOR 765-1802 BUILDING DEPT. INSPECTION [ ] FOUNDATION 1ST [ ]/RDUGHPLBG. / [ ] FOUNDATION 2ND [v~ INSULATION [ ] FRAMING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION REMARKS: DATE INSPECTOR 765-1802 BUILDING DEPT. [ ] INSPECTION FOUNDATION 1ST []'//]ROUGH PLBG. ] F/OUNDATION 2ND [ ]INSULATION FRAMING [ ] FINAL [ ] FIREPLACE & CHIMNEY R, EMARKS: ~'~'-~) ~' ,.sP.CTO. DATE / August 18, 2004 Southold Town Building Department Southold, N.Y. Re: Mr. Thomas Doolan 1850 Jockey Creek Drive Southold, N.Y. 11971 Building Permit # 30397 Z To Whom It May Concern: In reference to the framing ~nspection dated August 16, 2004 we would like to clarify and certify the following items: After the oak stair nosing is applied to the middle winding stair platform, the stair will conform to the remaining riser heights. The nosing had not yet been installed at the time of your inspection. Subsequently it has been installed and added an additional 3A" height to the platform. Two supporting wall structures (see attached drawing) were missing two additional wall stt~ds to create a bearing wall condition under the microllam beam. The microllam beam is supporting the floor toad only, the supporting walls Will be covered with 5/8" fire-code sheetrock, there will be a storage unit (floor to ceiling) built in between the two walls. Additional strapping will be provided at the double stud to beam condition. questions please contact our office at 631-298-1129. · ITECNOLOG!E_S August13,2004 Southold Town Building Department Southold, N.Y. Re: Thomas Doolan 1850 Jockey Creek Drive Southold, N.Y. B.P. # 30397 Z To Whom It May Concern: Enclosed please find four (4) revised sets of construction documents for your review. A utility sink has been added to the original proposed and approved building department set in the 2r~ floor addition over the existing garage. If you have any additional questions please feel free to call our office at 631-298-1129. June 7,2004 Southold Town Building Dept. Southold, N.Y. Re: Thomas Doolan 1850 Jockey C~ek Drive Southold, N.Y. 11971 S.C.T.M # 1000-70-5-20 To Whom It May Concern: Per requirements by New York State Residential Construction Code we certify that the design criteria is done per prescnptive design. All of the load calculations and structural plans comply with all of New York Construction Code based on (AF&PA) for One-Family Dwelling to the best of our knowledge. you have any additional questions please feel free to call our office at 631-298-1129. Cc: Doolan File  COMMENTS FOUNDATION (1ST) FOUNDATION (2ND) TOW~r~ ~ THOLD BUILD~?~ B~]~ARTMENT TOWN HilL ~ SOUTHOI~D, NY 11971 TEL: (631) 765-1802 FAX: (631) 765-9502 www. northfork.net/Southold/ Examined Approved Disapproved a/c Expiration I$11~ PERMIT NO. BUILDING PERMIT APPLICATION CHECKLIST Do you have or need the following, before applying.'? Board of Health 4 sets of Building Plans Planning Board approval Survey Check Septic Form N.Y.S.D.E.C. Trustees Contact: Mail to: ,20 ) ~ ! B~-~ldin~ II~spect~B?~--'''~ ~" B ~ : , PPLICATION FOR BUILDING PERMIT : ~i,~: Date ,_~_~ ~9 ,200~ : :~ ~'~ INSTRUCTIONS .(j - a. TNs application MUST be completely filled in by t~ewfiter or in i~ ~d sub~tted to the Bulldog Nspector with 3 sets ofpl~, acetate plot plan to scale. Fee according to schedule. b. Plot pl~ showing location of lot and of buil~ngs on presses, relationsNp to adjoin~g pre~ses or public s~eets or ~eas, and wate~ays. c. The work covered by this applicmion may not be co~enced before issu~ce of Building Pe~t. d. Upon approval oftNs applicmion, the Building ~spector will issue a B~lding Pe~t to ~e applic~t. Such a prat shall be k~t on the pre~ses available for inspection t~oughout ~e work. e. No buil~ng sMll be occupied or used in whole or in pa~ for ~y p~ose what so ever ~til the B~lding ~spector issues a Ceaificate of Occupancy. f. Evew building pe~t sh~l expire if the work authorized has not co~enced witNn 12 months a~er the date of issmnce or ~s not been completed withN 18 months ~om such date. If no zoning mendments or other re~lations affecting the prope~y have bern emoted in ~e Nt~ the Building ~pector ~y authorize, in writing, the extension of~e pemt for ~ addition six mont~. ~erea~, a new p~t shall be requked. ~PLICATION IS HE,BY M~E to the Building D~ment for the issu~ce of a Buil~g Pe~t p~su~t to the Building Zone Ordi~ce of the Town of Sou~old, Suffolk Co~ty, New York, ~d other applicable Laws, Ordin~ces or Re~lations, for the construction of buildings, addition, or alterations or for removal or demolition as herein described. The applic~t a~ees to comply with all applicable laws, ordin~ces, buil~ng code, housing code, ~d re~lations, ~d to a~t au~ofized inspectors on pre~ses ~d in b~lding for necess~ inspections. (Signature of apl~li~ant or name, ifa corporation) (Mailing ad~tres~6fapplicant) ' ' State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder Name of owner of premises "T-5-~ 0~,.~%<o t-O0 o/---~ ~ (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. Plumbers License No. Electricians License No. Other Trade's License No. 1. Location of land on which proposed work will be done: House Number Street ~ Hamlet County Tax Map No. 1000 Section ~'TCD Subdivision Lot Lot Block ~ Filed Map No. (Name) 2. State existing use and occupancy ofpremises and intended use and occupan.cy ofproposed constr~io~ a. Existing use and occupancy ~' ~o~c~',~ ~_.~%, c[~.~w~o~ [~?~On~,2 -(~ b. Intended use and occupancy ~\~. ~Oorv~'~ x,~ z-c_o~c 3. Nature of work (check which applicable): New Building. Repair Removal Demolition Estimated Cost ~ 20, O~:.b Fee Addition Alteration Other Work ~ [. o~ t_J~ c~ (Description) If dwelling, number of dwelling units If garage, number of cars (To be paid on filing this application) Number of dwelling units on each floor If business, commercial or mixed occupancy, specify nature and extent of each type of use. k~ [-}or Dimensions of existing structures, if any: Front ~4~--'1 ~ Rear Height ~ ~5,'- ~" Number of Stories 1 + ~-oJm~c~ Depth Dimensions of same structure with alterations or additions: Front Depth '2 ,'-t-'-o" Height 8. Dimensions of entire new construction: Front Height Number of Stories 9. Size of lot: Front -~-~c~t Rear Rear .Depth Depth 10. Date of Purchase ~} ~q Name of Former Owner ~ I ~ 11. Zone or use district in which premises are situated ~--~O ~--~-~ I"E:~ txk~l-[ 'Pr L- 12. Does proposed construction violate any zoning law, ordinance or regulation? YES __ NO 13. Will lot be re-graded? YES__ NO 'q/Will excess fill be removed from premises? YES __ 14. Names of Owner. of premises-T~o~z5 ~ Address~~ ~ ~- ,Phone.~c No. Name of Architect '~-a_~- I4.cr}-o-~c'o Address ' '~Z~3- k~l~on~V-No Name of Contractor Address Phone No. 2~o - 1~2at 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES__NO . . * IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet ora tidal wetland? * YES )~ NO * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at I 0 feet or below, must provide topographical data on survey. STATE OF NEW YORK) SS: COUNTY ~'~ ~)COC~-~ ~>(9 ~A~ID~'~ being duly sworn, deposes and says that (s)he is the applicant (~-~Name of individual'slgning contract) above named, q~-~'~Y~ (Contractor, Agent, Corporate Officer, etc.) (S)He is the of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are tree to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. Sworn to before me this  y e~blic JOYCE M. VVILKIN$ Notary Public, State of New York No. 4952246, Suffolk County Term Expire~ June 12, Signature of Applica~t ~ ~R NC SYSTEM / 1-3/4" X 11-7/8" GPI-80 F.J. 16" O.C. DBL. I 3/4" X 11 7/8" FLUSH MICROLAM BEAM : · DBL. I 3/4" X 11 7/8" FLUSH MICROLAM BEAM 1-3/4" X 11-7/8" WI-80 F.J, 16" O.C. 1-3/4" X 11-7/8" GPI-80 F.J. 16" O.C. /aoo- 7~-,r-z~I'OWN OF SOUTHOLD PIIOPERTY RECORD CARD OWNER STRE~ /~_q-o V,L~GE D,ST. S~'". FOYER OWNER / ~ ~, W ~ ~PE OF BUILDING RES. ~ /0 S~S. VL FAkM COM~. CB. MICS. Mkt. Value ~N~ ~M~. mo~*b ~*~ ~KS ' ' ~A ' ' ~' -, ~ ' - ' AGE BUILDING CONDITION N~ NOR~L BELOW ABOVE FA~ Acre Value Per Value Acre Tillable FRONTAGE ON WATER W~land FRONTAGE ON ROAD Meadowla~d DEPTH Ho&se Plo~ .... BULKH~D Total DOCK COLOR TRIM M: Bldg. Extension Exte.~;on Extension Porch Breezewc~/ Garage Patio O.B. Total Foundation Ext. Walls Fire Place Bath , Floors ..... Interior Finnish Heat Dinette ~DR. IBR. ;~pe Roof Recreation ROOm Rooms 1st' Floor RooMs 2nd Floor Driveway FIN. B Permit Number Checked By/Date REScheck Compliance Certificate New York State Energy Conservation Construction Code REScheckSoftware Version 3.5 Release la Data filename: \\NOTARO\SharedDocs\CheckLREScheck~DOOLAN.rck TITLE: THOMAS DOOLAN COUNTY: Suffolk STATE: New York HDD: 5750 CONSTRUCTION TYPE: Detached 1 or 2 Family HEATING TYPE: Non-Electric DATE: 06/07/04 DATE OF PLANS: JUNE 1, 2004 PROJECT INFORMATION: ALTERATION TO EXISTING 2-CAR ATTACHED GARAGE COMPANY INFORMATION: ARCHITECNOLOGIES 13405 MAIN ROAD MATTITUCK, N.Y. 11952 * GROUND SNOW LOAD - 45 PSF * EXPOSURE CATEGORY B * 120 MPH WIND SPEED * SEISMIC DESIGN CATEGORY - B * WEATHERING - SEVERE * WINTER DESIGN TEMP. - ZONE I lB - 11 DEGREES * ICE SHIELD UNDERLAYMENT REQUIRED NOTES: - R-3 SINGLE FAMILY DWELLING - HEIGHT - 20'-6" FROM GRADE TO RIDGE - AMERICAN FOREST AND PAPER ASSOCIATION (AF&PA) WOOD FRAME CONSTRUCTION. - SITE PLAN - DEMOLITION PLAN - FIRST & SECOND FLOOR PLAN - FIRST & SECOND FLOOR FRAMING PLAN - ROOF FRAMING PLAN - BUILDING SECTION - ENERGY CALCULATIONS/NAILING SCHEDULE CONSTRUCTION DETAILS. COMPLIANCE: Passes Maximum UA - 117 Your Home UA = 61 47.9% Better Than Code (UA) Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA Ceiling 1: Cathedral Ceiling (no attic) 520 38.0 Skylight 1: Vinyl Frame:Double Pane with Low-E 6 Wall 1: Wood Frame, 16" o.c. 414 21.0 Window 1: Vinyl Frame:Double Pane with Low-E 14 Window 2: Vinyl Frame:Doable Pane with Low-E 13 Window 3: Vinyl Frame:Double Pane with Low-E 14 Window 4: Vinyl Frame:Double Pane with Low-E 14 Window 5: Vinyl Frame:Double Pane with Low-E 14 Window 6: Vinyl Frame:Double Pane with Low-E 35 Floor l: All-Wood Joist/Truss:Over Unconditioned Space 957 Air Conditioner 1: Electric Central Air, 10 SEER Boiler 1: Other (Except Gas-Fired Steam), 80 AFUE Air Conditioner 2: Electric Central Air, 10 SEER 38.0 15.0 7 0.300 2 11 0.310 4 0.310 4 0.320 4 0.320 4 0.310 4 0.320 11 0.010 10 COMPLIANCE STATEMENT: The proposed building represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed systems have been designed to meet the New York State Energy Conse~r~on'._Lne~,el~ftion Code requirements. When a Registered Design Professional has stamped and signed this page, they are a~t~~'~f his/her knowledge, belief, and professional judgment, such plans or specifications are in comL~~~ Builder/Designer ~l IL~ttN~a'~b.. ~,O.E. Date ~ 7.657 REScheck Inspection Checklist New York State Energy Conservation Construction Code REScheckSofiware Version 3.5 Release 1 a DATE: 06/07/04 TITLE: THOMAS DOOLAN Bldg. Dept. Use [ ] [ ] [ I [ ] Ceilings: 1. Ceiling 1: Cathedral Ceiling (no attic), R-38.0 cavity + R-38.0 continuous insulation Comments: Above-Grade Walls: 1. Wall l: Wood Frame, 16" o.c., R-21.0 cavity + R- 15.0 continuous insulation Comments: Windows: 1. Window 1: Vinyl Frame:Double Pane with Low-E, U-factor: 0.310 For windows without labeled U-factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ Comments: ] No Window 2: Vinyl Frame:Double Pane with Low-E, U-factor: 0.310 For windows without labeled U-factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ Comments: ] No Window 3: Vinyl Frame:Double Pane with Low-E, U-factor: 0.320 For windows without labeled U-factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ Comments: ] No Window 4: Vinyl Frame:Double Pane with Low-E, U-factor: 0.320 For windows without labeled U-factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ Comments: ] No Window 5: Vinyl Frame:Double Pane with Low-E, U-factor: 0.310 For windows without labeled U-facturs, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ Comments: ] No Window 6: Vinyl Frame:Double Pane with Low-E, U-factor: 0.320 For windows without labeled U-factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ Comments: ] No Skylights: 1. Skylight 1: Vinyl Frame:Double Pane with Low-E, U-factor: 0.300 For skylights without labeled U-factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: Floors: 1. Floor 1: All-Wood Jois~YTruss:Over Unconditioned Space, U-factor: 0.010 Documentation must be submitted verifying the overall assembly U-factor. The U-factor must be developed in accordance with accepted engineering practice. Comments: [ [ [ ] [ ] [ ] [ ] [ ] [ ] [ ] [ ) ( ) [ ] [ ] [ ] [ ] [ ] [ ] [ ] ( ] Heating and Cooling Equipment: ] 1. Air Conditioner 1: Electric Central Air, 10 SEER or higher Make and Model Number ] 2. Boiler 1: Other (Except Gas-Fired Steam), 80 AFUE or higher Make and Model Number ] 3. Air Conditioner 2: Electric Central Air, 10 SEER or higher Make and Model Number Air Leakage: Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. Recessed lights must be 1) Type lC rated, or 2) installed inside an appropriate air-tight assembly with a 0.5" clearance from combustible materials. If non-lC rated, the fixture must be installed with a 3" clearance from insulation. Vapor Retarder: Required on the warm-in-winter side of all non-vented flamed ceilings, walls, and floors. Materials Identification: Materials and equipment must be installed in accordance with the manufacturer's installation instructions. Materials and equipment must be identified so that compliance can be determined. Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. Insulation R-values and glazing U-factom must be clearly marked on the building plans or specifications. Duct Insulation: Supply ducts in unconditioned attics or outside the building must be insulated to R-8. Return ducts in unconditioned attics or outside the building must be insulated to R-4. Supply ducts in unconditioned spaces must be insulated to R-8. Return ducts in unconditioned spaces (except basements) must be insulated to R-2. Insulation is not required on return ducts in basements. Duct Construction: All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives), mastic-plus-embedded-fabric, or tapes. Duct tape is not permitted. Exception: Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions. Cooling ducts with exterior insulation must be covered with a vapor retarder. Air filtem are required in the return air system. The HVAC system must provide a means for balancing air and water systems. Temperature Controls: Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space temperature set point of the largest zone. Electric Systems: Separate electric meters are required for each dwelling unit. Fireplaces: Fireplaces must be installed with tight fitting non-combustible fireplace doom. Fireplaces must be provided with a source of combustion air, as required by the Fireplace construction provisions of the Building Code of New York State, the Residential Code of New York State or the New York City Building Code, as applicable. Service Water Heating: Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part ora circulating system. Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: HVAC piping conveying fluids above 105 °F or chilled fluids below 55 OF must be insulated to the levels in Table 2. Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non-Circulating Runouts Temperature (F) Up to 1" Up to 1.25" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Circulating Mains and Runouts 1.5" to 2.0" Over 2" Table 2: Minimum Insulation Thickness for HE4C Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Pipin~ System Types Range (F) 2" Runouts 1" and Less 1.25" to 2" 2.5" to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 Low Temperature 120-200 0.5 1.0 Steam Condensate (for feed water) Any 1.0 1.0 Cooling Systems Chilled Water, Refrigerant, 40-55 0.5 0.5 and Brine Below 40 1.0 1.0 1.5 2.0 1.0 1.5 1.5 2.0 0.75 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only) · ' . u-d}3gTH T. T~ILiRY TOWI~ CLEI~K OFFICE OF THE TOWN CLERK TOWN OF SOUTHOLD THIS IS TO CERTIFY THAT THE FOLLOWING RESOLUTION WAS ADOPTED BY THE SOUTHOLD TOWN BOARD AT A REGULAR MEETING HELD ON AUGUST 211, 1'993: RESOLVED that the Town Board of the Town of Southold hereby adopts two (2) new forms to be used under thle Flood Damage Prevent regulations of the Code of the Town of Southold: "Floodplain De~,elopmen.t Permit Application" [FDP(9])], and /;'Certificate of Compliance ~'r Oevelopment in Special Flood Hazard Area [(~/C(93)}. BLDG. 02FT TOWN OF Southold Town Clerk August 25, 1993 TOWN OF SOUTHOLD APPLICATION # PAGE I of 4 FLOODPL3AN DE\CELOPMENT PERMIT APPLICATION This form is to be filled out in duplicate. SECTIQN 1: GENERAL PROV1SIONS (APPLICM'~T to read and siwn]: L No work may start until a permit b issued. 2. The permit may b~ revoked if any false statement~ are made herein_ 3. If revoked, all work must cease tmtil permit b re-isaued. 4. Development shall not be wed or occupied until a Certificate of Compliance is issued. 5. The permit will exph'~ d ho work is commenced within s~x moath~ of issuance. 6. Applicant is hereby informed that other permits may be requised to flflftLI local, state and federal regulatory requlrcmcat~ ?. Appllr. ant hereby gives consent to thc Local Administrator or hb/hcr rcprescatativ~ to make reasonable lu~pectlous required to verify compllance. 8.I, THE A~PLI~, CI~RTIF'Y THAT ALL STATEMEIqT$ HEREIIq AND hq' ATTACI-[M .F4NT$ TO · (A~F LiCAN-i~$ $ i ~ HATU R~ ~ .~:~'~-~,~v.,~ DATE ; $~CTlOH ~: PROFO$~D D~LELO~M~HT ~To ~¢ completed ~v AFI~ICA~q~ NAME ADDRESS TELEPHONE PROJECT LOCATION: To avoid delay in proce~hag the zpplicado~ please provide enough information to easily identify the project location. Provide the ~u'eet address, lot number or legal description (attach) and, outside urbaz~ re'cas, the distrmce to the ucasext intersecting road or ~ll-knowu L~dmzric A sketch attached to thLs application showing thc projcc~ location would be helpful. FDP(9]) AY PLICA TIQN ~ PAGE 2 OF 4 DESCRIPTION OF WORK (Check ail apptlc~blc boxes): A. STRL}CTURA~L DEVI~LOPMEhFF ~CTIVITY STRUCTURE TYPE ~i(~csideotial (1-4 F~nily) ~D Residential (More than 4 FmiJy) Ul Non-residential (Floodproofmg? C] Yes) ~ CombLned Use (Residential & Commercial) ~ Cl Manufactured (Mobile) Home (In Maim- factored Home P~rk?. Cl Ye-s) ESTIMATED COST OF PROIECT i .~,t)~ C] New Structure ~j~ddJdon [] Alteration [] Relocation [] Dcm0tition [] Replacement B. OTHER DEVELOPMENT ACTIVITIES: El F'dl [] Mining ~1 Drilling [] Grading O Excavation (Except for Struaural Development Checked Above) -- El Watercourse Alteration (Indudlog Drcxtging and Charmel Modifications) El Dralnagc Improvements (Including Culvert Work) El Road, Street or Bridge Co tstructioo [] Subdivision (New or Exp):~sion) ~ Individual Water or Scv.~.r System [] Other (Please Specify) After completing SECTFION 2, .&PPL[CAIxFF shotdd submit form to I~cM AdmbaLscrator for re.,.4cw. ~EGTION 3: FLOQDPLAIN DETERMINATION (To be completed by LOCAL ADMINISTRATOR) Thc proposed development b located on ~ Panel No. , Dated The Proposed Development: [] Is blOT located in a Special Flood Hazard Area (Notify the appticam that thc application review La complete and NO FLOODPLAIN DEVELOPMENT PERMIT IS REQUIRED}. C] L~ loc. areal in a Spedal Flood Hazard Area. FIRM z. one de,signation is tOO-Year flood elevation a[ thc silo is: Ft. NGVD (MSL) [] Unavailable Thc proposed development is located in a floodway. FBF~vl P:mol No. Dated SIGNED [)ATE APPLICATION PAGE 3 OF 4 SECTION 4: ADDITI~qAL INFO~LMATION REOUIRED ~To hc com~cd bY LO~ ~DM Thc appfi~t mus~ submit thc documents checked below bc~orc (bm apportion ~ bc proc~scd: 0 A si~c pl~ sho~gthc [o~tion of~l c~t~g strucl~cs, water bodics, adj~ccn~ roads, d~ensio~ ~d proposed development. 0 Dcvclopmcm phns, &a~ to stole, md spedfimt~, iociudin~ where appH~blc: detfils for ~chorlng structure, proposed elevation of lowest floor (~dud~g b~emcu0, t~es of r~s~l~t materials used below the f~st flora, det~ of floodprooFmg of u~ties lo.ted balow ~e f~sl floor ~d d~t~s of ~ndos~es below thc fi~st floor. CI Subdivision or other development plaxts (If thc subdi,fisioo or other development exceeds .rio lots Or 5 a~, whichever ~ the I~sser, ~ appear ~ust pro~d~ t~-ye~ flood elevations ~ ~cy ~c not atheist av~ab[~). O Pl~ sho~g th~ ~t of watcrco~s~ rcl~tioo ~d/qr I~om ~teratiom- ~ Top of u~w ~ el~tioa FI. HG~ (MSL). ~ ~dproo~mg prote~iou I~vcl (aon-r~ideutifi o~y) Ft) NG~ (MSL). For flo~proofad s~ctur~, appE~ot m~ attach ~rt~tlou [rom re~tered ~n~ or ~ Ce~tiou from a re~stered e~eer that th~ proposed a~:~ ~ a rc~ato~ Uoodway ~fl ~ot r~u[t ~ ~ ~cre~ ~ the heigkt of ~e ~-yc~ flood. A copy of ~ data ~d ~c~atio~ sup~rt~g t~fi~ fimd[ng m~l also be ~ubmittcd. C) Other: SECTION 5: PER.MIT DETERMIHATIOIq (To be completed bY l~9J~-AL ADMI._H[~TRAT_QR) ! h~ive determined that the proposed activity:. A.. 0 ts B, CI Is not in coufomance with provisio~ of Local Law ~ , 19 . Thc permit Lq issued subject to thc cooditioni attached to and made part of this pemit. SIONED , DATE BLf_~A is checked, ibc Local Admiaktrator may bsue a Development Permit upon payment of designated Lff BOX. B i~ checked, ibc Local Administrator w01 provide a written summary o( deficiencies. Applicant may revise and resubmit an application ~o ~he Local Administrator or may request a bearing from the Boa.rd of Appeals APPLICATION PAGE 4 OF 4 APPEALS: Appealed to Boazd of Appeals? [3 Yes O No Hea~mg date: Appeals Board D¢¢bioo --- Approved? [] Yes Coach6ons 0 No SEqTI'ION 6: AS-gUILT EL£VATION~ (To bc submitted bv APPLICANT before CertLficatc qf Compliance b issuedl The following information mu~t be provided for project structures. This seclioo mu~t be completed bY a registered profe~ional engineer or a licensed land surveyor (or attach a certification to tkis application), Complete I or 2 below. 1. Actual (A~-Built) Elevation of the top of ~he lowest floor, indudlag basement ~ a a ' za' Areas, bottom of lowest stlmctural member of the lowest floor, exdudlng pillng and columns) rt. ~OV~ 2_ Actual (A~-Built) Elevation of floodproo£mg protection b FI'. NGVD (MSL). NOTE: Any work per[ormed prior to submlttal/01, thc above information Ls at the risk ,51' the Applicant. / / ,.SECTION 7: COMPLIANCE ACTION (To be completed I)¥ LOCAL ADMINISTRATOR) The LOCAL ADMIH[STRATOR will complete tb/s section a.s applicable based oa inspection o1' the project to ensure compliance with the community's local law [or flood d~mage prevention. INSPECTIONS: DATE BY DEFICIEbICIES? [] YES O NO DATE BY DEFICIENCIES? [] YES [] NO DATE BY DEFICIENCIES? C] YES C3 NO SECTION 8: CERTIFICATE OF COMPLIANCE(To bc comnleted by LOCAL ADMIINI~;TRATOR~ C*.rtLficate of Compliance L~ued: DATE: BY: for Attachment B / SAMPLE CERTIFICATE OF ComPLIANCE// Development in a Special F[ooO' Hazard Area TOWN OF SOtJTHOLD CERTIFICATE OF COMPLIANCE [;'OR DEVELOPMENT IN A SPECIAL FLOOD FDLTakRD (OWNER MUST RETAIN THIS CERTIFICATE) PREMISES LOCATED AT: PERMIT NO. p ERiMIT DATE OVfix/ERS NAME AND ADDRESS: CHECK ONE: I-I NEW BUILDING [] EXISTING' BUILDING [] VACANT LAND / THE LOCAl. ADMINiSTILATOR IS TO COMPLETE A. OR B. BELOW: COMPLIANCE IS HEREBY CERTIFIED WI111 THE REQUIREMENTS LOCAL LAW # , 19 SIGNED: DATED: OF COMPLL'd'4CE IS HEREBY CERTIFIED WITH THE REQUIREMENTS OF LOCAL LAW #__, 19__, AS MODIFIED BY VARIANCE #_ , DATED. SIGNED: DATED: C/C[93) KEY MAP SKALE 17~7e' ~OCKEy CRr~ AREA=50,78J SQ. ~ TO 77E UNE ELEVA17ONS REFERENCED TO N.G. V.D. '29. ANY ALTERATION OR ADOI170N TO IHI$ SURVEY tS A ~IOLATION OF SECTION 720~ OF THE NEW YORK STATE EDUCATION LA~ EXCEPT AS PER SECTION ?209-SUBDIVISION .2. ALL CERTfFtCA TtONS HEREON ARE VALID FOR THIS MAP AND COPIES THER£OF ONLY IF SAID MAP OR COPIES BEAR THE IMPRESSED SEAL OF 17'tE ~URVEYOR WHOSE SIGNATURE APPEARS HEREON. APPROVED AS PER TERMSt A~O Co~DmosS O~ pERMIT blOs DATE SOU t. IC. NO. 496h 765- 1797 03-246 GENERAL NOTES: I ALL WORK SHALL COMPLY WITH FEDERAL, STATE, AND LOCAL BUILDING CODES AND ORDINANCES 2, BEFORE COMMENCEMENT OF WORK, THE CONTRACTORS SHALL FURNISH THE OWNSR AND ARCHITECT WITH COPIES OF ALL REQUIRED INSURANCE AND WORKER'S COMPENSATION CERTIFICATES AND NAMES OF ALL SUBCONTRACTORS, 3, THE CONTRACTORS SHALL BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB, THE ARCHITECT MUST BE NOTIFIED OF ANY VARIATIONS FROM THE DIMENSIONS SHOWN, 4, THE CONTRACTOR SHALL SUPPLY ALL LABOR AND MATERIAL SHOWN ON THE DRAWINGS UNLESS OTHERWISE NOTED, 5, THE CONTRACTOR SHALL BE RESPONSIBLE FOR ADEQUATELY BRACING AND PROTECTING ALL WORK DURING CONSTRUCTION AGAINST DAMAGE, BREAKAGE, COLLAPSE, DISTORTION, AND MISALIGNMENT ACCORDING '1'O ALL APPLICABLE CODES, 6, THE CONTRACTOR SHALL PAY FOR AL PERMITS, FEES, AND COSTS RELATED TO THE WORK OF THIS CONTRACT, CONTRACTORS SHALL INITIATE ALL REQUIRED INSPECTIONS OF ALL WORK COMPLETED UNDER THIS CONTRACT, 7 THE CONTRACTOR SHALL AT ALL TIMES KEEP THE PREMISES CLEAN AND IS RESPONSIBLE FOR REMOVAL OF ALL RUBBISH FOR ALL TRADES FROM THE JOB SITE, 8, ANY "EXTRAS" FOR ALL OR LEGITIMATE UNFORESEEN CONDITIONS SHALL SE DOCUMENTED WITH THE COST OF APPROVAL BY OWNER OR HIS AGENT PRIOR TO STARTING ADDITIONAL WORK, 9. DOUBLE JOISTS ARE TO BE INSTALLED UNDER ALL WALL PARTITIONS RUNNING PARALLEL TO THE FRAMING, PROVIDE DOUBLE HEADER JOISTS AT ALL OPENINGS, REFER TO CONSTRUCT DRAWINGS FOR SIZES, 10, ALL FRAMING LUMBER TO BE DOUGLAS FIR #2 CONS , GRADE OR BETTER, 11, THE CONTRACTOR SHALL PROVIDE SHOP DRAWINGS FOR ALL SPECIAL WORK SUCH AS BUT NOT WHITED TO, MILLWORK, SPRINKLER SYSTEMS AND STEEL WORK, ALL SHOP DRAWINGS NEED THE APPROVAL OF THE ARCHITECT BEFORE PROCEEDING, INSULATION NOTES: - NEW EXTERIOR WALLS: 2"X6" WOOD STUD, R-21 FOIL FA, HIGH DENSITY INSULATION BY 'CERTAINTEED' OR APPROVED EQUAL, - NEW ROOF: R-38 KRAFT-FA, INSULATION BY 'CERTAINTEED' OR APPROVED EQ. - CRAWL SPAOE: R-21 KRAFT-FA, INSULATION WITH PROPER WIRE TIES INSTALLED AS PER N.Y.S, BUILDING CODE. - BASEMENT PERIMITER, NEW BASEMENT: R-10 RIGID FOAM 2'0" BELOW GRADE AROUND ENTIRE - BASEMENT CEILING: R-21 KRAFT-PA. INSULATION WITH PROPER WIRE TIES INSTALLED AS PER N,Y,S, BUILDING CODE. MINIMUM 2' 0" UNDER FIN, GRADE - CRAWL SPACE WALL: R-19, MINIMUM 2'-0" UNDER FIN, GRADE, CONSTRUCTION LEGEND NEW EXTERIOR PARTITION- 2" X $" WOOD STUD WALL W/1/2" CDX PL'r~VD, EXTERIOR SHEATHING ( ThNEK WRAPPED & TAPED), CLEAR CEDAR 5" EXPOSURE BEVELED SIDING OR APP, LQ, PROV,1/2" GYP ED.(SCREWED/TAPED) CLR, PINE 5" COLONIAL BASE TRIM, & R-21 FOIL FACE INSUL (HIGH DENSITY), 3 1/2" WIDE CLEAR PINE COLONIAL TRIM ON ALL WINDOWS & DOORS ALL WINDOWS TO HAVE STOOL, NEW INTERIOR PARTITION- 2" X 4" WOOD STUD WALL WITH 1/2" GYP, DB, (SCREWED/TAPED) APPLIED BOTH SIDES, NOTE. PROVIDE MOISTURE RESIST GYP. BB. (GREEN MD,) FOR ALL BATHROOM WALL AND CEILINGS. PROV, CEMENT WALL MD. FOR ALL TILE AREAS. INTERIOR PAINT-TO BE "BENJAMIN MOORE" U.O,N, ONE COAT PRIMER AND TWO COATS FINISH (COLORS T,B,D. BY OWNER) SATIN FIN, THROUGHOUT U,O N. ALL TRIM SEMI-GLOSS, HARDWOOD FLOORING-SELECT ~4,~1 RED OAK 2 1/4"W,, 15LB. FELT,,UNDERLAYMEN1 (3 FINISH COATS OF CLEAR SATIN POLYURETHANE,) SUB-FLOOR-USE 3/4" THICK PLYWOOD GLUED AND NAILED, SUB FOR TILE AREAS TO BE SCREWED AND GLUED, CERAMIC TILE - "AMERICAN OLEAN" TILE OR APR, EQ. TILE TO BE INSTALLED OVER 1/2" CEMENT BOARD U,O,N. WALL AND FLOOR GROUT TO HAVE WATERPROOF ADDITIVE MIXED IN, DOOR SCHEDULF 1 ST,FLOOR INTERIOR DOORS DOOR OPERATION LOCATION MATERIAL WOOD LEFT GARAGE DOOBID PANELS TED PLUMBING LEGEND PROV, ALL NECESSARY PLUMBING ROUGHING AND VENTING AS iNDICATED Ip ON CONSTRUCTION pLANS), FOLLOW ALL NECESSARY N,Y.S, BUILDING CODES THAT APPLY TO WORK BEING COMPLETED. PROV, ALL NECESSARY DRAIN VALVES. CONNECT TO PLUBMING IN LAUNDRY ROOM BELOW, ELECTRICAL LEGEND: NOTE: ALL ELECTRICAL WORK TO BE IN ACCORDANCE WITH THE RULES AND REGULATIONS OF THE N Y B,F,U, AND A CERTIFICATE FROM THE N Y,B,F,U, IS TO BE PRESENTED TO THE OWNER AT THE COMPLETION OF THE JOB, NOTE: THE OWNER SHALL PROVIDE ALL LIGHTING FIXTURES UNLESS OTHERWISE NOTED, ALL OTHER ELECTRICAL EQUIPMENT AND MAT'L TO BE SUPPLIED BYTHE ELECTRICAL CONTRACTOR, NOTE: ALL SWITCHES AND RECEPTACLES TO BE ~LUTRON', ~'DECORA" IN COLOR O,N.O,. DOWNLIGHT TRIMS TO BE WHITE, {~ DUPLEX ELECTRICAL RECEPTACLE $ ISa WALL SWITCH I 3-WAY WALL SWITCH ~Ja MOUNTED JUNCTION BOX CEILING ~F EXT, MOUNTED LIGHT WITH FAN SMOKE DETECTOR/CARBON MONOXIDE DETECTOR: TO BE HARD WIRED ISD TO CENTRAL CONTROL BOX. "~oT MULTI FUNCTION COMBINATION CABLE WINDOW LEGEND ALL WINDOWS TO BE ANDERSEN. RIGID VINYL PVC CLADDING EXTERIOR/PRIMED WOOD INTERIOR/ALL ANDERSON HARDWARE WINDOW SPECS ANDERSEN ROUGH ROUGH REFERENCE OPENING OPENING QTY, NUMBER WIDTH HEIGHT * THESE WINDOWS MEET NATIONAL AND LOCAL EGRESS CODES FOR FIRE EVACUATION, NOTE: ALL INTERIOR CASING TO BE STANDARD COLONIAL CASING CLEAR PINE UNLESS OTHERWISE NOTED NOTE: ALL WINDOWS TO BE MARVIN INTEGRITY WITH STANDARD MARVIN HARDWARE AND FULL DIVIDED LITES, ALLOW FOR EXTENSION JAMBS FOR A 2" X 6" WD, STUDWALL COLOR TO~ BE WHITE, PROV SCREENS FOR ALL WINDOWS, STORAGE TIE ALL ELEC, INTO EX, ELEC. PANEL, PROV, ADD'L CIRC. FROM EX, BOILER FOR NEW HEAT ZONE PROPOSED STUDY PROV I ZONE COOLING SYSTEM 1-F,C,U, + CONDENSER 1/2 HR. F,C, GYP B( :,",,'2D IN WALL & CEILING OF GARAGE I I I I FCU FOR NC SYSTEM PROV, ADEQUATE SUPPORT 1-2/4" X 11-7/8" CPI-80 F,J, 16" O,C, DEL I 3/4" X 11 7/8" SECOND FLOOR PLAN FIRST FLOOR PLAN SECOND FL. FRAMING PLAN D 0 2 J 1/4!'~ 1 '0" DWG, NAME: FLOOR PLANS DyVG. NE),: iA.1 TECO R.R TO 8 1/2" X 9 1/2" PROVIDE FU LL-LENGHT "COBRA" RIDGE VENT DEL, 2" X 12" RIDGE BEAM 5/8" CDX PLYWOOD SHEATHING (ON 15LB. FELT TYP, ALL AREAS) PROV. "WEATHERWATCH" UNDER- LAYMENT UP 2'-0" ROOF EDGE, 2" X 12" RIDGE BEAM PROV. 2" X 4" "FLYING RAKE~' 1 0'-6" 6'- 1 0" 31 FA, INSUL, (TYP, ALL AREAS) ALUMINUM CUTLER TECO R.R TO 3 1/2" X 9 1/2" MICROLAM BEAM. 2" X 6~' EXT, STUD WALL. PROV. 1/2" CDX pLYWOOD Wf'TYVEK HOMEWRAP" UNDER ALL EXT, SIDING, 7'-1 0" 1 3/4" X 11 7/8" CPI-B0 F,J. @ 16" O,O, DEL, I 3/4" X 11 7/8" MICROLAM BEAM 2'-1 1" R-21 FOIL FA INSULATION. (TYPICAL ALL AREAS) EXISTING ROOF DBL. I 3/4" X 11 7/8" MICROLAM BEAM PROV. BIRDSMOUTH IN EX. RAFTER FOR MICROLAM. 4" DIA, STR. STL COLUMN LEFT SIDE BLDG SECTION PANEL LEGEND (REFER TO TABLE 1609.1.4) PANEL SIZE REF T/zPE AND # OF SCREWS WIDTH I ¢8 SCREWS C¢ 12" O.C "Al" HORIZONTAL 3 VERTICAL - 4 2'-11 '~ X 4'-11" #8 SCREWS @ 16" O.C "El" HORIZONTAL - 7 VERTICAL - 3 6'-7" X 2'-9" #8 SCREWS @ 12" O.C, ~'01" HORIZONTAL- 9 VERTICAL 4 7'-8" X 4'-11" ¢8 SCREWS @ 12" O.C "D1" HORIZONTAL - 3 VERTICAL - 3 2'-11" X 3'~7" NOTE: REFER TO A, 1 WINDOW & DOOR SCHEDULES FOR PANEL LOCATIONS. 3 - HORIZONTAL ~)5 - VERTICAL 9 - HORIZONTAL (~4 - VERTICAL 7 - HORIZONTAL ~)3 - VERTICAL ALTERNATIVE FOR OPENING PROTECTION WOOD STRUCTURAL PANELSWlTH A MINIMUM THICKNESS OF 7/16 AND MAXIMUM PANEL SPAN OF 8-0 SHALL BE PERMITTED FlOR OPENING PROTECTION IN ON AND TWO STQRY BUILDINGS, PANELS SHALL BE PRECUT TO COVER GLAZED OPENINGS WITH ATTACHMENT HARDWARE PROVIDED. (REFER TO SECTION 18D9.1.4 ADD 1609,6,5 AND TABLE 1609,1,4) TABLE 1609.1.4 WINDBORNE DEBRIS PROTECTION FASTENING SCHEDULE FOR WOOD STRUCTRAL PANELS PANEL SPAN ~< 2'-0" < PANEL 4'-0" < PANEL 6'-0" < PANEL FASTENER TYpE LEFT SIDE ELEVATION 2' X 3' SKYLIGHT, PROV, ALL NEC, FLASHING, AND MISC, REAR ELEVATION REMOVE ALL EXISTING R,R,, SHEATING, SHINGLES _~T__TC, T__O ALLOW F~OR N~EW C~O N S__TR U C__TION __ DEMOLITION PLAN NEW ROOFING PROV. DBL. R.R. FRONT ELEVATION (ALT. B_)_ , I L.LI "' 7 icc , ~ 0 SCALE: 1 I ~/4'~= 1 '0" DWG NAME I P~OPOSED ELEVATIONS/ IPAN~LPLAN IA.2