Loading...
HomeMy WebLinkAbout31272-ZFORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. I:Islam 9301R00:1"Iaaw (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 31272 Z Date JULY 13, 2005 D16 Permission is hereby granted to: _ JAMES P. & ANGELA M. O'DOHERTY I 19869 GRENBRIAR DRIVE Iv v V TARZANA,CA 91356 for : CONSTRUCTION OF A NEW SINGLE FAMILY DWELLING WITH ATTACHED GARAGE AS APPLIED FOR. (REPLACES BP ##30523-Z) at premises located at 1825 MILL PATH SOUTHOLD County Tax Map No. 473889 Section 056 Block 0001 Lot No. 005.001 pursuant to application dated JULY 13, 2005 and approved by the Building Inspector to expire on Tr* ,nov Fee $ 1,305.30 kft= xaiw ORIGINAL Rev. 5/8/02 FIELD INSPECTION REPORT DATE COMMENTS FOUNDATION (IST) ------------------------------------ ro 3 `y x FOUNDATION (2ND) ROUGH FRAMING & PLUMBING z 0 ?7 ..3 V INSULATION PER N. Y. STATE ENERGY CODE y FINAL C ADDITIONAL COMMENTS % "-a - s T1 T1 a to y O z l� x rA d r �d TOWS` OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL SOUTHOLD, NY 11971 TEL: (631) 765-1802 FAX: (631) 765-9502 www. northfork.net/Southold/ 11 Examined % 20 Approved i 204 Disapproved a/c Kpiration / 20�1 3) �2? -Z- PERMIT NO BUILDING PERMIT APPLICATION CHECKLIST Do you have or need the following, before applying? Board of Health 4 sets of Building Plans Planning Board approval Survey Check Septic Form N.Y.S.D.E.C. Trustees Contact: Mail to: CATHERINE C. 1 PhJ21AILLP0,fND I ANE _.— E. MORICHES, NY 11940-1222 -to 3 1 -97 F- $9 51 APPLICATION FOR BUILDING PERMIT Date / 3 , 2004 - INSTRUCTIONS _`­`a.This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 3 sets of plans, accurate plot plan to scale. Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application, the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e. No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim, the Building Inspector may authorize, in writing, the extension of the permit for an addition six months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County, New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances, building code, housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. (S1gnaVl"lR" IY RAI�I�/I r. o p cant) F. ffICHES, NY 11940-1222 State whether applicant is owner, lessee, agent, architect, engineer, general contract,ctrician, plumber or builder " D 0 HxP_ 7-%/ Il 0 r2 Ha- Lf V Name of owner of premises (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. Plumbers License No. _ Electricians License No._ Other Trade's License No. 1. Location of land on which proposedOA-r-" ork will be 1 l d o�.s 1 `� \ 1 L.L O A T " House Number Street County Tax Map No. 1000 Section (o Block ( Lot—6 Subdivision Filed Map No. Lot _ (Name) N 1 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy VOLe Cjn b. Intended use and occupancy C U nsru c4 i o n a i� 2, 4>,!F -r. 6,4 R. G Poo 1, Poo/ JJ h uvs e. 3. Nature of work (check which applicable): New Building n Addition Alteration Repair Removal Demolition Other Work (Description) 4. Estimated Cost If dwelling, number of dwelling units If garage, number of cars _ Fee (To be paid on filing this application) Number of dwelling units on each floor 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structuV6\ if any: Front Height Number of Stories, Rear Depth Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction: Front Rear S Z Depth 3S. S Height Number of Stories 9. Size of lot: Front f 4- 0 2 r Rear 4-74-1 Depth 6 W 1 314 10. Date of Purchase 3 /r_ AN c, - aow Name of Former Owner L /-� N (� t7owA O'OvrfEa.rY pE�vD�Ny 11. Zone or use district in which premises are situated ;)o 12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO X 13. Will lot be re -graded? YES NO X Will excess fill be removed from premises? YES NO 14. Names of Owner of premises Address Phone No. Name of Architect Address Phone No Name of Contractor Address Phone No. 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO * IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY BREQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NC x * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. STATE OF NEW YORK) SS: COUNTY O&r o/ k^ A) 0aTt4E!P_j,UiF 1 "1 ES IA A!0 being duly sworn, deposes and says that (s)he is the applicant (Name of individual signing contract) above named, (S)He is the (Contractor, Agent, Corporate Officer, etc.) 5N1)`4 of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. Sworn tp, �efore me this Z% day of 206 1 � Notary Public CAROL BEST No" Public State of ftw Ybtk G4d10972 C.00 �20 07 Signature of Applicant APPLICANT W DATE SUBMITTED: /x/04 SCTM# DISTRICT: 1,000, SECTION:.576, BLOCK: A_, LOT: SUBDIVISION: �nhmo ap a ADDRESS: It? hy;pk ���� ICS CITY: c su�(���� ZONING DISTRICT: CONFORMING?_ BUILDING PERMITS OPEN/EXPIRED: PV CO: Y OR N BP -Z / C/0 Z- , INFO /BP -Z / C/0 Z- , INFO BP -Z / C/0 Z- ,INFO /BP -Z / C/0 Z- , INFO SINGLE & SEPARATE CERTIFICATION -REQUIRED g Q NOTES: , LOTS 40,0008F -100-24. Lot recognition.(CREATED before June 30, 1983), UNDERSIZED LO; FROM JAN.1997 100"25. Merger.(A nonconforming at any time afte REQ. LOT SIZE:- 'eDl ACT. LOT SIZE:3 7e, `REQ. LOT COV. �O ACT. LOT COV. REQ. FRONT � �� PROP. FRONT C VAREQ SIDE �ft �ACT. SIDE REQ. REAR Dr PROP. REAR REQ. HEIGHT PROP. HEIGHT FJ�.q-��y �,� ti PROJECT DESCRIPTION: +�:r�ri)-„&3A_�� gay t E a ESTIMATED PROJECT COST,'t) (r e) k, ARCHITE-- r/ENGINEER: l > WATERFRONT? DESCkIPTION: APPROVALS REOUIRED PANEL # FLOOD ZONE;, SUFFOLK COUNTY HEALTH DEPOYESNO, (BED #): DTE: 2 /2'V/ V PERMIT #: i� 0 01,dd ��TOWN SEPTIC RECEIPT: Y or N' NEW YORK STATE DEC: PRE -DEC 9/1/75 YES or 0 DTE: / / PERMIT #: SOUTHOLD TOWN TRUSTEES: YES o 0DTE / / PERMIT #: TOWN ZONING BOARD APPROVAL: YES or _ DTE: _// PER:'v1IT #: TOWN PLAIN. BOARD APPROVAL: YES or a O � DTE _/ / �ERMIT #: TOWN WSTORICAL(PRE (SPLIA): ES o NO / NEW YORK STATE CODE COM IANCE (SEE PAGE 2): YES or NO {_ NOTES: 0' 0aD-A,,, B � (,�. i FEE STRUCTURE: FOUNDATION: ' 451, SF FIRST FLOOR: SF SECOND FLOOR: SF OTHER:- SF 4'ki INIT TOTAL: SF FEE 1.( 1-01 SF)- CS\—,D SF)= 3 '' SFX $_3() =$ 1155 +$ . 15_0 +$ 2. (_SF)- (—SF)=. 3. (_SF)- (SF)= SF X $—=$—+$ +$ SFX $ _$ +$ +$ OTHER TOTAL FEE FEE _$ FINAL TOTAL: $ 15 NEW YORK STATE CODE COMPLIANCE CHECKLIST CLIMATIC/GEOGRAPHIC DESIGN CRITERIA: Jwoo� Ground Snow Load: 45 Wind Speed: 120MP,11 Seismic Ye'sign Category: B Weathering: Severe"Frost Depth: 36" "J' Termite: M -H Decay: S -M DesignTemp:11 �Ice Shield Underlay: YES J Flood Hazards: USE/OCCUPANCY CLASSIFICATION: HEIGHT/FIRE AREA TYPE OF CONSTRU DESIGN CRITERIA: FULL FRAMING DESIGN ELEMENTVrl/N HEADERS: Y/N WALL STUDS: Y/N CEILING JOISTS: Y/N FLOOR JOISTS: Y/N LUMB-2 R SPECIES AND GRADE: Y/N DESIGN. LOAD CALCULATIONS )-IN GIRDERS.: Y/N ROOF RAFTERS: Y/N LIVE: Y/N DJ%V� Y/N I SNOW: Y/N SEISMIC: Y/N WIND: Y/N WINDOW AN4' OOR SCHEDULE: "`!f-W-AT.,REQUIREME NTS&N E-6RESS- 5:7-&RY/N . k -'HT 80Y(- Y/N/ VENT 4%: Y/N 0-QN C NAIL CONS -TR CTION SCHEDULE MEANS OF EGRESS: Y/N PLUMBING RISER DIAGRAM: �IN LOCATION OF FIRE PROTECTION EQUIPMENI(5./N TRUSS DESIGN: Y/N CERTIFICATION: Y/N ENERGY CALCS&' N - TOTAL COMPLIENCE? Y/N (RETURN TO PAGE ONE) now °r torn-iela Norton CX. � Edward Ernst games p Keay / formerly Cv0Cont) �o,29930 N mO'A E �_ / 93.57 MON 4N fOrmel �y now or Southold Town (vocont) PlP'. }oN 474.02' 7W E1=17.6 0 N51,25'00„E m o ,lRn 'c.,r wi O S fy tP R7 I 9 ��s� G,�, ., c:°F1�a�li►rAv�! NES PROP ONDRTY M , TED i 1� �it f1PLJ f i�! n?.••i� �I A$ 'a M t 64 �� — �° 6 14121 /� rL 9C” Ln 0 11+r^`r��o �\ Qs D l UNiv P I Tin 1 N a -�l oez C— O 4- 0 N 0 "t N N 0 LT O_ S79'52'00"W 33.35' �R OWNED R N' DW P ASH„ KNAS S PO o � LE � ZES H0 LO .O N EL=15.4 579.52p0„W O� .............. ..... 8 00 W 224.90' now Or fOA geld Norton Edward Ernst & es p. Kelly J formerly (\lacant) ... by Dept. of Waafth Ufvt C.I. COVERS�j' PROPOSED TO GRAD / VVVIIIV HOUSE FF=21.0± FINISHED GRADE EL=20.1 EL=19.7 EL=19.1 'MIN IE=18.1 IE - 1 I.z IE=17.1 T $'I WWI? _ --- e.o• — la ` �� ! •� � �(Q MIN. I GROUND WATER EL=12.1 SEP11C TANK CESSPOOL TEST HOLE DATA 1750 GAL. 475 S.F•S.W.L.A. MCDNOVOOSLD OGOEOSCIENCEt �[ / ^fig nbpi��+Q! i;�+,"s _ 3 —;;i;— NOV. _ _ JVEPAR�� L D7S5aa�t♦l G7 EL=15.5 0.0 DARK BROWN 'erstaAAl+y� MIt Arpno A, OF 0014U ®N FOR A CLAYEY LOAM 1<iLII��ana ��5�+ h`I " 1� rQa� ?m Fi',Igr-r"`r ONV? v / X10 -ds r o�S- 1.0 Rw BROWN DATE /s •/N® CLAYEY SAND Tr�.E� `� PALE BROWN �°®ItR IP:�i�f�®F. BEDR'Ui�!iVS;� i )^ FINE TO ~ COARSE SANDECpMES HRBF,-y-EARS.RO;�Ji�i9P,'k�.�i � '�"aJ G.W. ---- .4' J EL=12.1 WATER IN PALE BROWN �a FINE TO .. COARSE SAND 13.0' "'. '"`i: FEB. 09, 2004 HD AMENDMENTS DATE: OCT. 25, 2003 .InR Nn- gnn3-55n Survey for: JAMES 0'D OHER T Y At Arsh,amomaque Town of Southold Suffolk County, New York S. C. T. M.: 1000-056.00-01.00-005.001 100 0 100 I SCALE:1 "=100' NOTES: 1. AREA = 318,005 S.F. 2. ■ = MONUMENT FOUND, • = PIPE FOUND. 3. REFERENCE DEED; L. 9414 P. 107. 4. ELEVATIONS SHOWN HEREON ARE REFERENCED TO APPROXIMATE N.G.V. DATUM (MSL 1929). 5. ZONING USE DISTRICT = R-80 6, WETLANDS IF ANY NOT SHOWN HEREON. CERTIFIED TO: JAMES O'DOHERTY DAVID H. FOX N.Y•S.L•S. #50234 FOX LAND SURVEYING PO BOX 224 SPEONK, N.Y. 11972 (631) 325-2902 UNAUTHORIZED ALTERATION OR ADDITION TO THIS SURVEY IS A VIOLATION OFSECT10N 7209 OF THE NEW YORK STATE EDUCATION LAW. COPIES OF THIS SURVEY MAP NOT BEARING THE. LAND SURVEYOR'S INKED SEAL OR EMBOSSED SEAL SHALL NOT BE CONSIDERED TO BE A VALID TRUE COPY. CERTIFICATION INDICATED HEREONSHALL RUN ONLY TO THE PERSON FOR WHOM THE SURVEY IS PREPARED AND ON HIS BEHALF TO THE TITLE COMPANY, GOVERNMENTAL AGENCY AND LENDING INSTITUTION LISTED HEREON AND TO THH ASSIGNEES OF THE LENDING INSTITUTION CERTIFICATICNS ARE NOT TRANSFERABLE TO ADDITIONAL INSTITUTIONS �\ OR SLESE OIL NT OWNERS. DWG: 2003-550 or formerly or formerly Norton / now Of Southold now Angelo Town Ernst & An9 �vaaartti) James P• Kelly / P ?W TO GRADE Edword 3°N PROPOSED C.I. COVER 47 A .Ori N HOUSE formerly (vQ ant) Y L FF=21.0t / EL=17.6 FINISHED GRADE / O E1=20.1 EL=19.7 N80.2g'301- Nai•2600"E o m W E 2.0' MAX E=19.1 N D OPK 93.5 TREE v IE=17.2 la MON Ys � �- EL=15.0 MIN. I ` I GROUND WATER EL=12.1 ' PROPERTY LINES 1 ONUMENTED u • As M- oo �� SEPTIC TANK CESSPOOL 6506 6y� 1 TEST HOLE DATA 1750 GAL. 475 S.F.S.W.L.A. p MCDONALD OSCIENCE 'NOV. n�1 qfl� 1 NOV. 05, OO 1 ' EL=15.5 0.0 0 c)N 1 S60 DARK BROWN CLAYEY LOAM r N 1.0 aONE� j zoo �• CJ� BROWN O/ CLAYEY SAND p, \ ° 0 o \ �� Q Ci 3.0' a o HN2 G o \\ (n 0 PALE BROWN o % FINE TO oG0 o y 0 P�wrc^� COARSE SAND O Q Q G.W. — — — — 3.4' O EL=12.1 WATER IN PALE BROWN a FINE TO -)3 Q o COARSE SAND aY�Yc� 13.0' c�EO OP S9I p O U) �' FEB. 09, 2004 HD AMENDMENTS s 6M n "-A DATE: OCT, 25, 2003 Survey for: JOB NO: 2003-550 N � CERTIFIED TO: JAMES O'D OHER T Y JAMES O'DOHERTY At A o 4- N� �� `�, Arshamomaque io ��� CD CID Town of U) `0 Southold 9��, Suffolk County, New York CD N Q '�.tES"C Hp1.E •61 O �� i 0) 4' �6oP"`� S.C•T.M.: 1000-056.00-01.00-005.001 �L `L P`P� CO t?5 0O•O oq6' / C'y'N6P" 100 0 100 N. Y. S. L. S. SCALE: 1"=100' DAVID H. FOX EL=157 1 _ - - N88'38°00"W 224.90' �? FOX LAND SURVEYING S79'S200"33. W S6�G01 33 g5' NOTES: PO BOX 224 �/ EL=154 57g•5200"�9. 1. AREA = 318,005 S.F. S (601) X325-29102 2 / / / ROADWAY formerly 2. ■ = MONUMENT FOUND, s = PIPE FOUND. �- UNAUTHORIZED ALTERATION OR ADDITION TO THIS D r rton 3. REFERENCE DEED; L. 9414 P. 107. IS A VIOLATION OFSECTION 7209 OF THE NEW YO lipNor "NULL PATH E nst & p\ngeW N° 4. ELEVATIONS SHOWN HEREON ARE REFERENCED EDUCATION LAW. COPIES D THIS SURVEY MAP N THE LAND SURVEYOR'S INKED SEAL OR EMBOSSES SHALL NOT BE CONSIDERED TO BE A VALID TRUE Edward James p,Y,01Y TO APPROXIMATE N.G.V. DATUM (MSL 1929), CERTIFICATION INDICATED HEREON SHALL RUN ONI formerly5. ZONING USE DISTRICT = R-80 PERSON'FCR WHOM THE SURVEY IS PREPARED A' `' ` BEHALF TO THE TITLE COMPANY. GOVERNMENTAL �y aCan` AND LENDING INSTITUTION LISTED HEREON . AND 6, WETLANDS IF ANY NOT SHOWN HEREON. ASSIGNEES OF THE LENDING INSTITUTION. CERTIFIC/ DWG: 2003-550 ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE= CODES OF NEW YORK STATE. ��A,F�TIpFI(G; ATaIAO��+- OF ROOFING SHINGLES 1IAIL.ING `�ONNE`j -TIONS RIDGE VE ��Q�II12 9 ADJUST OVERHANG TO MATCH SOFFITS VINYL SIDING — — — - STEP FOOTING 30 DEG MAX FRONT ELEVATION COMPLY WITH ALL CODES OF NEW YORK STATE & TOWN CODE! AS REQUIRED AND CONDITIONS 0 SOUTHOLD TOWN ZBA SOUTHOLD TOWN PLANNING BOAF SOUTHOLD TOWN TRUSTEES N.Y.S. DEC PLUMBER CERTIFICATION ON LEAD CONTENT BEFORE CERTIFICATE OF OCCUPANCY SOLDER. USED IN WATER SUPPLY SYSTEM CANNOT EXCEED 2/10 OF 1% LEAD. II DO NOT PROCEED WITH FRAMING UNTIL SURVEY OF FOU NDATIO - ELEVATION HASBEENA L�_________�_ GE UPANCY OR IS UNLAWFUL CERTIFICATE.' UPANCY PLUMBING ALL PLUMBING WASTE a WAFER LINES NEED tiTiNa BEFORE COVERING UNDERWRITERS CER i IFILA; REQUIRED AS NOTED DATE: B.P. FEE: �3®J BY: NIOTIFY BUILDING DEPARTMENT AT 765-1802 8 AM TO 4 PM FOR THE FOLLOWING INSPECTIONS: 1. FOUNDATION - TWO REQUIRED FOR POURED CONCRETE 2. ROUGH - FRAMING & PLUMBING 3. INSULATION 4. FINAL CONSTRUCTION MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. FLOOD ZOO . >N COMPLY WITH CHAPTER "46" QED A� FLOOD DAMAGE -PREVENTI F NIC C`y�� SOUTHOLD TOWN CODE. RETAIN STORM WATER OF PURSUANT TO SECTION C 0 OF THE TOWN CODE. 0F=v7-1C.e-- - GENERAL NOTES 1.THE ARCHITECTS CERTIFICATION APPLIES ONLY TO DEMONSTRATING THE DESIGNS CONFORMANCE TO THE BUILDING CODE OF THE STATE OF NEW YORK 2. ALL MATERIALS, ASSEMBLIES, CONSTRUCTION AND EQUIPMENT IS TO BE IN ACCORDANCE WITH THE BUILDING CODE OF THE STATE OF NEW YORK AND MANUFACTURERS INSTRUCTIONS. 3. VERIFY ALL DIMENSIONS BEFORE AND DURING CONSTRUCTION, NOTIFY ARCHITECT OF DISCREPANCIES. DO NOT SCALE DRAWINGS. 4. DEVIATION FROM THESE PLANS, UNAUTHORIZED DUPLICATION OR REUSE WILL NEGATE ARCHITECTS CERTIFICATION AND IS A VIOLATION OF NYS LAW. DRAWINGS ARE THE COPYRIGHT OF THE ARCHITECT. 5. THE ARCHITECT IS NOT RESPONSIBLE FOR THE DISCOVERY, PRESENCE, PREVENTION, REMOVAL OR HANDLING OF ASBESTOS, HAZARDOUS MATERIALS, GASSES, FUMES, MOLD AND O MILDEW. S. THE ARCHITECT ASSUMES NO RESPONSIBILITY FOR CONSTRUCTION, MEANS METHODS, TECHNIQUES, SEQUENCES, PROCEDURES OR SAFETY PRECAUTIONS AND PROGRAM IN CONNECTION WITH THE WORK THE ARCHITECT SHALL NOT BE RESPONSIBLE FOR ERRORS OR OMISSIONS OF THE OWNER, CONTRACTOR OR SUB -CONTRACTORS. 7. THESE PLANS ARE OF LIMITED SCOPE AND ARE INTENDED FOR USE BY EXPERIENCED OWNER(BUILDERS FOR CONSTRUCTION ON OWNERS PROPERTY WITH FINAL SPECIFICATIONS SELECTED BY THE OWNER. THE ARCHITECT, NOT CONTRACTED TO CONTROL THE CONSTRUCTION PROCESS IS NOT RESPONSIBLE FOR ASSURING THE FINAL AS CONSTRUCTED BUILDING AND SITE IS IN COMPLIANCE WITH ALL BUILDING CODES, LOCAL LAWS, REQUIREMENTS OR SUITABILITY FOR A PARTICULAR USE. THE ARCHITECTS LIABILITY TO OWNER OR ANY THIRD PARTY IS THEREFORE LIMITED ONLY TO THE FEE PAID FOR SERVICES RENDERED. B. USE OF THESE DRAWINGS INDICATES BINDING ACCEPTANCE OF THE ABOVE CONDITIONS AND ARE A PART OF THE AGREEMENT WITH THE ARCHITECT. R301.2 DESIGN CRITERIA: VALUE R301.2.1 WIND LIMITATIONS: GROUND SNOW LOAD 45 PSF DESIGN LOADS FOR WINDOWS AND BASIC WIND SPEED 120 MPH DOORS SHOWN WITH FLOOR PLAN SEISMIC CATAGORY C R301.2.1.1 WIND DESIGN CRITERIA WEATHERING SEVERE THIS BUILDING HAS BEEN DESIGNED FROST LINE DEPTH 36" MIN. WITH THE FOLLOWING APPROVED TERMITE PROBABILITY MOD/HEAVY REFERENCE FOR BASIC WIND DECAY PROBABILITY MODERATE SPEEDS OF 110 MPH AND ABOVE ICESHIELD REQUIRED SUGJESTED (ENCLOSED BUILDING): AFBPA FLOOR HAZARDS N/A WOOD FRAME CONSTRUCTION DESIGN LIVE LOADS PSF DEF. MANUAL (WFCM). NON SLEEPING ROOMS 40 9360 THIS BUILDING IS IN A SLEEPING ROOMS 30 LI360 WINDBORNE DEBRIS REGION. DECKS 40 9360 GLAZED OPENINGS ARE ATTICS WITH STORAGE 20 L240 REQUIRED TO BE PROTECTED AS ATTICS NO STORAGE 10 L240 PER THE REQUIREMENTS OF STAIRS 40 LI360 R301.2.1.2. SEE SHEET A-5 GUARDS/RAILS 2001 AT TOP R301.2.1.4 EXPOSURE CATEGORY& DEAD LOADS ARE BASED ON ACTUAL NORTH B SOUTH B MATERIAL WEIGHTS OF ASSEMBLIES EAST B WEST B ROOF SNOW LOAD AS PER ASCE 7 DWELLING IN SEISMIC CATAGORY CIS 45 PSF(0.7)(1)(1)(1) = 32 PSF EXEMPT FROM SEISMIC PROVISIONS BUILDING AREAS: SQFT FIRST FLOOR LIVING 1,289 SECOND FLOOR LIVING 1,275 TOTAL LIVING AREA 2,564 OPEN TO BELOW 139 GARAGE AREA 542 COVERED PORCH 306 Approximate gross floor areae based on nominal material dimensions. LMing areas Include first floor stairs and finished floor areas to the outside of house exterior walls and to one half of garage or open to below walls. Garage area Includes one half of house walla to outside of garage exterior walls. Second floor open to below space Includes stairs below. Decks and porch areas are from exterior walls to outside edge of decklporch. eric Nicosia ARGIAITELT in 414 Main Streel,Suite 203, Port Jefferson, N.Y. 11777 Telephone: (631) 928.4456. Fax: (531) 928-9543 Email: architect@optonline.net 1525 MILD PATH ROAD SOUTHOLD, N.Y. NOTE5 4 ELEVATION5-1 Job#:040170 Scale: 1/8"=1r-0" A—I Date: 6/7/04 1 BY: E.N. I Rev: ----------------------------- - — — — — — — — — — — — — — — — — — — — — — — — — — — — REAR ELEVATION LEFT ELEVATION i -I TT --- i II II ELEVATION REFERENCE NOTES R325.1 Approved numbers or addresses shag be provided for all new buildings in such a position as to be plainly visible and legible from the street or road fronting the property. R613.5.1 Window and glass door assemblies shall be anchored in accordance with the published manufacturer's recommendations to achieve the design pressure specified. Mullions shall be tested by an approved testing laboratory. Maximum mullion deflection= L/175, Mullions shall be capable of resisting a load of 1.5 times the design pressure loads. R703.1 The exterior wall envelope shall be constructed In such a manner as to prevent the accumulation of water within the wall assembly by providing a water resistive barrier behind the exterior veneer as required by Section R703.2. R806.3 Vent clearance. A minimum of a 1 -Inch (25.4 mm) apace shall be provided between the insulation and the roof sheathing at the location of all vents. R901. Roof assemblies shall be Installed in accordance with this code and the approved manufacturer's installation instructions such that the roof assembly shall serve to protect the building or structure. Flashings shall be installed In such a manner as to prevent moisture entering the wall through the jolnts in the coping, through moisture permeable material, at Intersections with the roof plane or other penetrations or changes in slope. Roof coverings shall be applied in accordance with the applicable provisions of this section and the manufacturers installation instructions. Underiaymentt shall conform with ASTM D 226, Type I, or ASTM D 4869, Type I. Self -adhering polymer modified bitumen sheet shallcomply with ASTM D 1970. Asphalt shingles shall have self -seal strips or be interlocking, and comply with ASTM D 225 or D 3462. Fasteners for asphalt shingles shell be galvanized steel, stainless steel, aluminum or copper roofing nalls,minlmum 12 gage shank with a minimum 318 -inch diameter head, Where the roof sheathing is less than 3/4 inch thick, the fasteners shall penetrate through the sheathing.Fasteners shall comply with ASTM F1667. Asphalt shingles shall have of six fasteners per shingle. Undedayment shall be applied shingle fashion, parallel to and starting from the save and lapped 2 inches, fastened sufficiently to hold In place. End laps shall be offset by 6 feet In areas where the averegedaily temperature in January is 25d or less, an ice barrier that consists of a least two layers of underlayment cemented together or of a self -adhering polymer modified bitumen sheet, shall be used in lieu of normal undedayment and extend from the eave's edge to a point at least 24 inches Inside the exterior wall line of the building.. Undedayment applied in areas subject to high winds greater than 110 mph shall be applied with corrosion resistant fasteners In accordance with manufacturers installation instructions. Fasteners are to be applied along the overlap not farther apart than 36 inches on center. Flashing for asphalt shingles shall comply with this section. Base and cap flashing shall be installed in accordance with manufacturers installation instructions. Base flashing shall be of either corrosion -resistant metal of minimum nominal 0.0194nch thickness. Cap flashing shall be corrosion resistant metal of minimum nominal 0.0194nch thickness. Valley linings shall be Installed In accordance with manufacturers Installation Instructions before applying shingles.Closed valleys (valley covered with shingles),valley lining of one ply of smooth roll roofing complying with ASTM D 224 Type II or Type III and atieast 36 inches (914 mm) wide or valley lining asdescribed in Items 1 and 2 above shall be permitted.Specially undedayment complying with ASTMD 1970 may be used in lieu of the lining material. A cdcket or saddle shall be Installed on the ridge side of any chimney greater than 30 Inches wide. Cricket or saddle coverings shall be sheet metal or of the same material as the roof covedng. Sidewall flashing. shall be by the step -flashing method. Other flashing against a vertical front wall, as well as soil stack, vent pipe and chimney flashing, shall be applied according to asphalt shingle manufacturers printed Instructions. ELEVATION CONSTRUCTION NOTES ROOFING: 6 NAILS PER SHINGLE ASPHALTIFIBERGLASS ROOFING SHINGLES AND ACCESORIES - SEE CODE NOTES ABOVE. ALUMINUM GUTTERS AND LEADERS TO SPLASH BLOCKS OR DRAINAGE AS REQUIRED TRIM: WHITE ALUMINUM CLADING. RAKE TRIM:1X2 ON 2X6, SPACE FOR SIDING. FASCIA: 2X8. CONTINUOUS VENTED VINYL SOFFITS. SIDING: VINYL SIDING AND ACCESORIES, WINDOW/DOOR DRIPEDGE, FLASHINGS, TAPED TYVEK HOUSE WRAP. VINYL SIDING TO CONFORM TO ASTM D3679. APPROVED U.L. LISTED FLUE CAP AND COLLER WITH SLOPED STAINLESS STEEL CHASE CAP. CHIMINYSIFLUES TO BE T-0" MINIMUM OVER ROOF AND 2'-0" MINIMUM HIGHER THAN NEAREST STRUCTURE WITH IN 10'-0". CRICKETS AND FLASHINGS AS REQUIRED IN R808. Eric Nicosia AFUITC.GT owl 414 Main Street,Sulte 203, Port Jefferson, N.V. 11777 Telephone: (631) 928-4456. Fax: (631) 9289543 Email: architect@optanline.nel 1525 MILL PATH ROAD SOUTHOLD, N.Y. NOTES 4 ELEVATION5-2 Job#:040170 Scale: 1/8"=1'-0" A-2 Date: 6/7/04 By: E.N. I Rev: 17,-A„ 52'-0" / PLYWOODANSULATE - / UNDER 7 CANTILEVER 2'-0" 12'-4" ANCHOR BOLTS TO BE WITHIN 6"-12" OF SILL PLATE ENDS OR SPLICES 6.. 5/8" ASTM 307 GRADE 60 THREADED L ANCHOR BOLTS AT 48" O.C. WITH NUTS AND 3"X3" X 12" SLOTED SQUARE WASHERS (SIMPSON L8PS12. R403.1 5/8" ANCHOR BOLT 48" O.C. H�o 10'-8" W CENTERLINE AT N INTERIOR BOLTS BAND -J 1---- -- SLOTED SQUARE WASHER 6" TO BOLT CENTERLINE 2" TO CORNER BOLT EDGE --'ZQ FOUNDATION WALL R403.1X CORNER BOLTS 41'-4" 6'-0" 1%a �"lI COS, /�� FOUNDATION NOTES: R323.1 In areas subject to decay damage and all wood in contact with the ground shall require the use of approved pressure preservatively treated or decay -resistant lumber. R324.3.1 Treat cut ends, notches & drilled holes In accordance with AWPA. R324 Subterranean termite control.Termite shields, Pressure preservatively treated wood In accordance with the AWPA standards and or termite -resistant wood. Chemical soil treatment may also be nessasary depending on site conditions. R401.3 Drainage. Surface drainage shall be diverted to drywells or other approved point of collection not to create a hazard. Lots shall be graded so as to drain water away from foundation walls a minimum of 6 Inches within the first 10 feet or swales shall be provided to ensure drainage away from the structure. R401.4.1 Geotechnical evaluation. In lieu of a complete geotechnical evaluation, the load-bearing values In Table R401.4.1 have been assumed. Compressible or shifting, soils shall be removed in conformance with R401.4.2 ASSUMED SOIL BEARING OF 2,000 POUNDS PER SQUARE FOOT APPLIES TO THE FOLLOWING CLASSES OF SOIL MATERIAL ONLY:GW,GP,SW,SP,SC,GM,GC NOTIFY ARCHITECT IF SITE CONDITIONS VARY FROM ASSUMED CONDITION. R402.2 Concrete. Materials used to produce concrete and testing thereof shall comply with the applicable standards listed In ACI 318 or ASTM C 1157. Reinforcing steel and Installation to be in conformance with ACI 318. Anchor bolts to be inconfornance with ASTM 307. MINIMUM CONCRETE COMPRESSIVE STRENGTH: 3,00D PSI @ 28 DAYS. CONCRETE AT BASEMENT FOUNDATION WALLS,EXTERIOR WALLS, PORCHS,STEPS AND GARAGE SLABS IS TO BE AIR ENTRAINED. IN CONFORMANCE WITH ACI318. NOMINAL SLUMP: WALLS 6, SLABS 5. R403 Concrete Footings shall be supported on undisturbed natural soils. All exterior footings shall be placed at least V-0" minimum below grade. The top surface of footings shall be level. Changes In elevations and ajacent slope requirements shall be in conformance with R403. R404.1Concrete Foundation Walls shall be constructed as set forth in section R404 and ACI 318. Backfill shall not be placed against the wall until the wall has sufficient strength and has been anchored to the floor above, or has been sufficiently braced to prevent damage by the backfill. Such bracing is not required for walls supporting less than 4 feet of unbalanced backfill. R405.1 Foundation Drainage. A drainage system is not required when the foundation is installed on well -drained ground or sandgravel mixture soils according to the Unified Soil Classification System, Group I Soils, as detailed In Table R405.1. Other soils require require drains in conformance with R 405.1 around all concrete or masonry foundations that retain earth and enclose habitable or usable spaces located below grade. R406.1Foundation dampproofing. Except where required to be waterproofed by Section R406.1 &2, foundation walls that retain earth and enclose habitable or usable spaces located below grade shall be dampproofed from the top of the footing to the finished grade by applying one of the listed dampproofing or waterproofing materials listed In Section R406 .In areas where a high water table or other severe soil -water conditions are known to exist, exterior foundation walls that retain earth and enclose habitable or usable spaces located below grade shall be waterproofed as per R4062 R407 Steel columns.All surfaces (inside and outside) of steel columns shall be given a shop coat of rust-Inhlbifive paint, except for corroslon-resistant and coated steel. Approved manufactured corrosion -resistant, coated steel columns with top bearing plate shall be bolted to the girder and the bottom with any adjustable threads on bearing plate embeded In the concrete slab. 6.5" MIN. WIDTH FOR TRIPLE W"ITU-T in a" DIA CAST I Telephone: (631) 926-4456. Fax: (631) 928-9543 3" DECK POCKET 1525 MILL PATH ROAD 12'x19' PC PIER 5/8" ANCHOR BOLTS 48" O.0 I FOUNDATION PLAN F_ 5/8" ANCHOR BOLTS 48 O.C. 'r50'_811 AIR SPACE ch IRON STEEL ORSOLID L DRAIN TO B" THICK 3,000 PSI AIR ENTRAINED CONCRETE WALLS ON I I DRYWEL. B" X16" WIDE CONTINUOUS, KEYED P.C. FOOTINGS ON 0 I I ASSUMED SOILS -SEE NOTES U.L. LISTED FLUE o VARY LENGTH FOR STEPS TO GRADE I Q 0 9' CLG Z t0S �' s1- zl BASEMENT N X N 4' THICK 3000 PSI PC .LAB ONXX O z I OR SUBGRADE j a U SAND BASE N 3 tD~A 40'-8" — FOOTINGS 30 DEG MAX 6'-9" 6'-11" 8'•9" T-9" 6'-9" 8'-9" a�2 NONCOMBUSTIBLE FIRESTOP AT FLOOR. &CEILINGS ivSTEP T =_ — — BEAM POCKET 58" ANCHOR BOLTS 48" O.C. BEAM POCKET ,^ I I C I I I I ON 3" DIA STEEL COLUMN ON ;. O I 2'-(Y'X2'-0"X1'-0" P.C. FOOTING i4 N r � � 15-4 0 m = 2 0 1 `� 4 3 J N 8,_0„ I ^ STEEL COLUMN ON 0 •— 10-2" O o I I o I 7D-0w-UX1'-91P.C. FOOTING N 3" DIA STEEL COLUMN ON - J I I N V `. 8., - P.C. FOOTING 7-0"X2'-a"All" N a 40-8 — — 518" ANCHOR BOLTS 48" O.C. J I � tb•a I I I I L UNEXCAVATED I` ---------------- CANTILEVER ABOVE I JOIST HANGER TO PPT LEDGER BOLTED TO RIM N a m 1 I II — — — — — — — — L BOARD WITH 12" DIA GALV. LAG BOLTS & I I I 4 WASHERS 16" O.C, STAGGER VERTICAL N B" 11,,6„ 8" T-8" v' 8'-0" 9'-0" k T-4„ T_0„ i T-0„ 1'_O I BEAM m 2-2XB PPT _ 3.2X8 PPT _ 2-2X8 PPT N POCKET — I — _ — — — — — — — — — — — — �� (2) 5/8" GALV. BOLTSMUTS/WASHERS THRU GIRDERS N 518" ANCHOR BOLTS 48" O.C. 8 4X4 PPT POST ON 17' MIN.DIA P.C. FOOTINGS WITH PA4 POST BASE AND 112' ANCHOR BOLT 12'-4" ANCHOR BOLTS TO BE WITHIN 6"-12" OF SILL PLATE ENDS OR SPLICES 6.. 5/8" ASTM 307 GRADE 60 THREADED L ANCHOR BOLTS AT 48" O.C. WITH NUTS AND 3"X3" X 12" SLOTED SQUARE WASHERS (SIMPSON L8PS12. R403.1 5/8" ANCHOR BOLT 48" O.C. H�o 10'-8" W CENTERLINE AT N INTERIOR BOLTS BAND -J 1---- -- SLOTED SQUARE WASHER 6" TO BOLT CENTERLINE 2" TO CORNER BOLT EDGE --'ZQ FOUNDATION WALL R403.1X CORNER BOLTS 41'-4" 6'-0" 1%a �"lI COS, /�� FOUNDATION NOTES: R323.1 In areas subject to decay damage and all wood in contact with the ground shall require the use of approved pressure preservatively treated or decay -resistant lumber. R324.3.1 Treat cut ends, notches & drilled holes In accordance with AWPA. R324 Subterranean termite control.Termite shields, Pressure preservatively treated wood In accordance with the AWPA standards and or termite -resistant wood. Chemical soil treatment may also be nessasary depending on site conditions. R401.3 Drainage. Surface drainage shall be diverted to drywells or other approved point of collection not to create a hazard. Lots shall be graded so as to drain water away from foundation walls a minimum of 6 Inches within the first 10 feet or swales shall be provided to ensure drainage away from the structure. R401.4.1 Geotechnical evaluation. In lieu of a complete geotechnical evaluation, the load-bearing values In Table R401.4.1 have been assumed. Compressible or shifting, soils shall be removed in conformance with R401.4.2 ASSUMED SOIL BEARING OF 2,000 POUNDS PER SQUARE FOOT APPLIES TO THE FOLLOWING CLASSES OF SOIL MATERIAL ONLY:GW,GP,SW,SP,SC,GM,GC NOTIFY ARCHITECT IF SITE CONDITIONS VARY FROM ASSUMED CONDITION. R402.2 Concrete. Materials used to produce concrete and testing thereof shall comply with the applicable standards listed In ACI 318 or ASTM C 1157. Reinforcing steel and Installation to be in conformance with ACI 318. Anchor bolts to be inconfornance with ASTM 307. MINIMUM CONCRETE COMPRESSIVE STRENGTH: 3,00D PSI @ 28 DAYS. CONCRETE AT BASEMENT FOUNDATION WALLS,EXTERIOR WALLS, PORCHS,STEPS AND GARAGE SLABS IS TO BE AIR ENTRAINED. IN CONFORMANCE WITH ACI318. NOMINAL SLUMP: WALLS 6, SLABS 5. R403 Concrete Footings shall be supported on undisturbed natural soils. All exterior footings shall be placed at least V-0" minimum below grade. The top surface of footings shall be level. Changes In elevations and ajacent slope requirements shall be in conformance with R403. R404.1Concrete Foundation Walls shall be constructed as set forth in section R404 and ACI 318. Backfill shall not be placed against the wall until the wall has sufficient strength and has been anchored to the floor above, or has been sufficiently braced to prevent damage by the backfill. Such bracing is not required for walls supporting less than 4 feet of unbalanced backfill. R405.1 Foundation Drainage. A drainage system is not required when the foundation is installed on well -drained ground or sandgravel mixture soils according to the Unified Soil Classification System, Group I Soils, as detailed In Table R405.1. Other soils require require drains in conformance with R 405.1 around all concrete or masonry foundations that retain earth and enclose habitable or usable spaces located below grade. R406.1Foundation dampproofing. Except where required to be waterproofed by Section R406.1 &2, foundation walls that retain earth and enclose habitable or usable spaces located below grade shall be dampproofed from the top of the footing to the finished grade by applying one of the listed dampproofing or waterproofing materials listed In Section R406 .In areas where a high water table or other severe soil -water conditions are known to exist, exterior foundation walls that retain earth and enclose habitable or usable spaces located below grade shall be waterproofed as per R4062 R407 Steel columns.All surfaces (inside and outside) of steel columns shall be given a shop coat of rust-Inhlbifive paint, except for corroslon-resistant and coated steel. Approved manufactured corrosion -resistant, coated steel columns with top bearing plate shall be bolted to the girder and the bottom with any adjustable threads on bearing plate embeded In the concrete slab. 6.5" MIN. WIDTH FOR TRIPLE W"ITU-T in / PLY LVL GIRDER - SEE PLAN Telephone: (631) 926-4456. Fax: (631) 928-9543 3" DECK POCKET 1525 MILL PATH ROAD 612" DEEP FOUNDATION PLAN – LVL POCKET � 1012" DEEP S _ o -3 AIR SPACE ch 3" MINIMUM BEARING STEEL ORSOLID SLATE SHIMS eric. Nicosia W"ITU-T in 414 Main Streel,Sulte 203, Port Jefferson, N.Y. 11777 Telephone: (631) 926-4456. Fax: (631) 928-9543 Email: architect@optonline.nel 1525 MILL PATH ROAD SOUTHOLD, N.Y. FOUNDATION PLAN Job#:040170 Scale: 1/8"=1'-0" -3 Date: 6/7/04 By: E.N. I Rev: 0 LIST OF ABBREVIATIONS ��kED A/�c NICQsyi�t<` t4, r ALL FRAMING LUMBER TO BE DOUGLAS FIR -LARCH #2. PRESSURE PRESERVATIVE TREATED LUMBER TO BE OF SOUTHERN PINE #2. TYPICAL HEADER SIZE IS TO BE 2-2X10 MINIMUM UNLESS NOTED NO HOLES ALOWED IN LVLS OR ANY HEADER/GIRDER. NOTCHING AND BORING OF SOLID SAWN JOISTS ARE TO BE IN CONFORMANCE WITH AF&PA WFCM. DOUBLE FJ UNDER TUBS, HEARTHS AND AT FRAMING OPENINGS. SOLID BLOCKING UNDER NON LOAD BEARING PARTITIONS.I JOISTS TO CONFORM TO MANUFACTURERS I NSTRUCTIONS. JOISTS/RAFTERS SHALL BE LOCATED DIRECTLY OVER TOP PLATES. SOLID BLOCKING/ SOLID WEB STIFFINERS AT ALL SUPPORTS. DIAPHRAM BLOCKING AS INDICATED. HAILERS FOR GYPSUM BOARD CEILINGS AS REQUIRED. FIRE/DRAFTSTOP CHASES AND PORCHS. LAMINATED VENEER LUMBER TO HAVE MINIMUM VALUES AS FOLLOWS E=2,000,000 psi, Fb= 2800 psi, Fv=285 psi LVLS TO HAVE MINIMUM OF 3" BEARING. NO HOLES ALLOWED IN LVLS. DOUBLE AND TRIPLE MEMBER LVLS ARE TO BE FASTENED TOGETHER WITH A MINIMUM OF 2 ROWS OF 16d NAILS 12" O.C., 3 ROWS OF 16d NAILS 12" O.C. FOR 14"-18" MEMBERS. SEE MANUFACTUTRERS INSTRUCTIONS FOR BOLTING OF FOUR MEMBER AND FASTENING OF SIDE LOADED MULTI -PLY BEAMS. CONNECT JOISTS TO FLUSH HEADERS, GIRDERS STEEL FRAMING HANGERS, AS PER MANUFACTURERS INSTRUCTIONS. SEE LOAD PATH/SECTION SHEET FOR ADDITIONAL ROOF STRAPS, HEADER AND SILL STRAPS HOLDOWNS, SHEAR WALLS, ETC. NAILING SCHEDULE - MS. I AF&PA WFCM REFERENCE NOT INCLUDING UPLIFT & HOLDOWN CONNECTIONS. LOCATION Common Nails - 12,_4„ 52,_0„ Telephone: (631) 028-4456. Fax: (631) 928-9543 Email: architect@optonline.net Roofing Shingles 6 roofing nails per shingle Structural Sheathing- Interior Zone Bd 6" o.c edge, 12" o.c. field Structural Sheathing- 4' Pedmiter Zone 8d 6" ox edge, 12" o.c. field 120 mph - Sheathing- 4' Pertmiter Zone Bd 6" ox edge, 6" o.c. field Sheathing @ Flush and Flying gables 8d W o.c edge, 6" o.c. field 120 mph - @ Flush and Flying gables 8d 4" o.c edge, 4" o.c. field 2-2X10 CCA STEPS sow per rafter Ceiling Jolst/rop Plate (toe -nailed) 3-8d perjoist Gelling Joist/Parallel Rafter (face -nailed) 3-16d each lap if CJ not on top plate Ceiling Joist Lap at Partition (face -nailed) 3-16d 6, 6'-6"paro Collar Tie to Rafter (face -nailed) 2-10d per tie 3-1 Od req @ 120 mph zones Blocking to Rafter (face -nailed) 2-8d each end Rim (fascia) to Rafter (end -nailed) 2-16d each end Gypsum Board - Ceiling 2M 28210 2-2X10 Q- (2) I -W X11-12' LVL TO2-FULL2X4P Ts WALL: N 3046-2 Gypsum Board - Wall W 7"o.c. edge, 10"o.c. field Structural Sheathing- 8d 6" o.c edge, 12" o.c. field 2-2X10 = SOLID METAL CLOTHS DRYER �' 1 — J ' 0" EXHAUST DUCT TO EXTERIOR WITH O _ _ _ _ _ _ _ — — — per foot Top Plat at intersections (face -nailed) 4-16d w o O m 2-0 Stud To Stud (face -nailed) 2-16d 24" o.c. Headers/Girders (face -nailed) 16d 16" o.c. along edges _ DAMPER, INSTALLED IN M 20'-6" per stud Top/Bottom Plate to stud (toe -nailed) 17,-4„ per stud °w � d - 2-16d per foot FLOOR: o CONFORMANCE WITH R1501 AND T-4" 4" 2' " 11 � Structural T&G Subfloor - glued & 8d 6" ox edge, 12" o.c.field. Joist to Sill/Plate/Girder (toe -nailed) 4-8d j m 0 0 Bridging to Joist (toe -nailed) 2.8d each and Blocking to Joist (toe -nailed) MANUFACTURERS INSTALLATION D each end Blocking to Sill or Top Plate (toe -nailed) 3-16d each block io " 0 0 each joist Joist on Ledger To Beam (toe -nailed) 3-Bd perjoist INSTRUCTIONS AND DETAILS VENT LAUNDRY 3-16d perjoist Band Joist to Sill/Plate (toe -nailed) 2.16d d ® O Z O LL POWERED NAILERS: USE MANUFACTURERS COMMON NAIL EQUIVALENT o 00 o Q 0� KITCHEN NOOK FAMILY A Y7 O�N J s 00 v 4„ T o n 4 0 w r a ❑ 0 ?3zn0 1 O D I xx0_ N FAI 2.2X10 2oee i❑ � ? a aL 6' 5'-6" 4" 11 1xwe CLOSET ao iv GYPSUM BOARD ON I - 3'-10" ' i� REF (2) 1-3/4" X B-1/2" LVL 2.2X10 (2)1.'l4" X LVL LING AND BEAMS W ITH 12' SUM BQARD ON INSIDE 7' 070' D01-8070 N USE W'pLL ADJOINING L BEARING WALL 7THICK o Udo 4 I + xmw ARAGE 4„U0�; I gq- o00 PSI AIR ENTRAINED P.C. m w G LL O t iA O o) SLAB ON SAND BAS OR SUBGRADE Z o - I $'�N ®� $ 6'_0„ = O OZ WITHeX610l10 WE EO WIRE MESH, XX PITCH SLAB TO OV RHEAD DOORS N U N DINING �, J " o j �:, 1 2 �., LIVING LL a o0 N o �u 12,_2„ 10,_2„ 0UP —1 Z — v (2)1.3/4" X 11-I16" FLUSH LVL ry - o aF U a — 15'$" o m N w Z Za Z d 16_6„ Z d 4" 9'-4" ❑ I I ° 2-2X10 'v 2-2X10 uJ O O 3046-2 / 6 _ _ 1468 _ _ _ 1466 iq 3048-2 a. Q. r b i5 \ / IIx iY z-�lo ❑ o a 4" 7'-9" 7'-9" 3M 4-8 4-8 7-9 7-8 3 5a m o ❑ o u7 d a" — — 22' 4'1 x a" COVERED PORCH 4 RPJLIN6 TO PORCH POSTS N 7 2.2X10 I m Q 2-2X10 2-2X10 2842 (2)1-39'X 11.1/4" LVL m 0 2-2x4 2-2X10 '¢a, N 2842 7'-61/2" 5" 7' 6" 5" 5„ 5" 6'-10" 5" 6,_2„ 6,_2„ 64„ 5,_4„ x 5/4"X6" PPT TOP RAIL ON 2X4 PPT 12'-4" 10'-8" 15'-6" 10'-0" 15'-10" FRAME WITH 4X4 PPT POSTS THRU DECK & MAX O.C. 2X2 PPT NEWEL 23'-0" 41'-4" POSTS - 4" MAX. CLEAR BETWEEN . , 84-4„ NEWELS WINDOWS ARE SHOWN AS ANDERSEN 400 SERIES TILTWASH WITH LOW E GLAZING. VERIFY ALL QUANTITIES, A ROUGH OPENINGS, MULLIONS, TEMPERED GLASS LOCATIONS BEFORE ORDERING WINDOWSIDOORS AND BEFORE FRAMING OPENINGS. MINIMUM DESIGN PRESSURE FOR WINDOWS AND MULLIONS = DP30 EXTERIOR DOOR ASSEMBLIES TO HAVE A MINIMUM DESIGN PRESSURE RATING = DP30. LIST OF ABBREVIATIONS ��kED A/�c NICQsyi�t<` t4, r ALL FRAMING LUMBER TO BE DOUGLAS FIR -LARCH #2. PRESSURE PRESERVATIVE TREATED LUMBER TO BE OF SOUTHERN PINE #2. TYPICAL HEADER SIZE IS TO BE 2-2X10 MINIMUM UNLESS NOTED NO HOLES ALOWED IN LVLS OR ANY HEADER/GIRDER. NOTCHING AND BORING OF SOLID SAWN JOISTS ARE TO BE IN CONFORMANCE WITH AF&PA WFCM. DOUBLE FJ UNDER TUBS, HEARTHS AND AT FRAMING OPENINGS. SOLID BLOCKING UNDER NON LOAD BEARING PARTITIONS.I JOISTS TO CONFORM TO MANUFACTURERS I NSTRUCTIONS. JOISTS/RAFTERS SHALL BE LOCATED DIRECTLY OVER TOP PLATES. SOLID BLOCKING/ SOLID WEB STIFFINERS AT ALL SUPPORTS. DIAPHRAM BLOCKING AS INDICATED. HAILERS FOR GYPSUM BOARD CEILINGS AS REQUIRED. FIRE/DRAFTSTOP CHASES AND PORCHS. LAMINATED VENEER LUMBER TO HAVE MINIMUM VALUES AS FOLLOWS E=2,000,000 psi, Fb= 2800 psi, Fv=285 psi LVLS TO HAVE MINIMUM OF 3" BEARING. NO HOLES ALLOWED IN LVLS. DOUBLE AND TRIPLE MEMBER LVLS ARE TO BE FASTENED TOGETHER WITH A MINIMUM OF 2 ROWS OF 16d NAILS 12" O.C., 3 ROWS OF 16d NAILS 12" O.C. FOR 14"-18" MEMBERS. SEE MANUFACTUTRERS INSTRUCTIONS FOR BOLTING OF FOUR MEMBER AND FASTENING OF SIDE LOADED MULTI -PLY BEAMS. CONNECT JOISTS TO FLUSH HEADERS, GIRDERS STEEL FRAMING HANGERS, AS PER MANUFACTURERS INSTRUCTIONS. SEE LOAD PATH/SECTION SHEET FOR ADDITIONAL ROOF STRAPS, HEADER AND SILL STRAPS HOLDOWNS, SHEAR WALLS, ETC. NAILING SCHEDULE - MS. I AF&PA WFCM REFERENCE NOT INCLUDING UPLIFT & HOLDOWN CONNECTIONS. LOCATION Common Nails - #NAILS NAIL SPACING ROOF/CEILING: Telephone: (631) 028-4456. Fax: (631) 928-9543 Email: architect@optonline.net Roofing Shingles 6 roofing nails per shingle Structural Sheathing- Interior Zone Bd 6" o.c edge, 12" o.c. field Structural Sheathing- 4' Pedmiter Zone 8d 6" ox edge, 12" o.c. field 120 mph - Sheathing- 4' Pertmiter Zone Bd 6" ox edge, 6" o.c. field Sheathing @ Flush and Flying gables 8d W o.c edge, 6" o.c. field 120 mph - @ Flush and Flying gables 8d 4" o.c edge, 4" o.c. field RafterJrop Plate (toe -nailed) 3-8d per rafter Ceiling Jolst/rop Plate (toe -nailed) 3-8d perjoist Gelling Joist/Parallel Rafter (face -nailed) 3-16d each lap if CJ not on top plate Ceiling Joist Lap at Partition (face -nailed) 3-16d each lap Collar Tie to Rafter (face -nailed) 2-10d per tie 3-1 Od req @ 120 mph zones Blocking to Rafter (face -nailed) 2-8d each end Rim (fascia) to Rafter (end -nailed) 2-16d each end Gypsum Board - Ceiling 5d cool 7"c.c, edge, 10"o.c. field WALL: Gypsum Board - Wall 5d cool 7"o.c. edge, 10"o.c. field Structural Sheathing- 8d 6" o.c edge, 12" o.c. field Top Plate to Top Plate (face -nailed) 2-16d per foot Top Plat at intersections (face -nailed) 4-16d joints -each side Stud To Stud (face -nailed) 2-16d 24" o.c. Headers/Girders (face -nailed) 16d 16" o.c. along edges Top/Bottom Plate to stud (end nail) 16d per stud Top/Bottom Plate to stud (toe -nailed) 2-10d per stud Bottom Plate to Floor Joist/Rlm 2-16d per foot FLOOR: Structural T&G Subfloor - glued & 8d 6" ox edge, 12" o.c.field. Joist to Sill/Plate/Girder (toe -nailed) 4-8d perjoist Bridging to Joist (toe -nailed) 2.8d each and Blocking to Joist (toe -nailed) 2-8d each end Blocking to Sill or Top Plate (toe -nailed) 3-16d each block Ledger Strip To Beam (face -nailed) 3-16d each joist Joist on Ledger To Beam (toe -nailed) 3-Bd perjoist Band Joist to Joist (end -nailed) 3-16d perjoist Band Joist to Sill/Plate (toe -nailed) 2.16d perfoot I -JOISTS IF APPLICABLE TO BE IN CONFORMANCE WITH MANUF. INSTRUCTIONS POWERED NAILERS: USE MANUFACTURERS COMMON NAIL EQUIVALENT eric Nicosia in 414 Main Streel,Suite 203, Port Jefferson, N.Y. 11777 Telephone: (631) 028-4456. Fax: (631) 928-9543 Email: architect@optonline.net 1825 MILL PATH ROAD SOUTHOLD, N.Y. FIRST FLOOR PLAN Job#:040170 Scale: 1/8"=1'-0" A-4 Date: 6/7/04 By: E.N. I Rev: 4 rn X_ V 10'-0" m � � x 0 o / ¢ i l _ l j- 10'-4" WIND BORNE DEBRIS PROTECTION Areas within hurricane prone regions within one mile of the coastal mean high waterline where the basic wind speed is 110 miles per hour or greater, or where the basic wind speed is equal to or greater than 120 miles per hour shall have glazed openings protected from windbome debris. Glazed opening protection for Wridbome debris shall meet the requirements of the Large Missile Test of ASTM E 1996 and of ASTM E 1886 referenced therein. Wood structural panels with a minimum thickness of 7/16 inch and a maximum span of 8 feet shall be permitted for opening protection in one- and two-story buildings. Panels shall be precut to cover the glazed openings with attachment hardware provided. Attachments shall be provided In accordance with Table R301.2.1.2 or shall be designed to resist the components and cladding loads determined in accordance with the provisions of the Code HARDWARE: 2-112"#B SCREWS 16" O.C. (12" O.C. IF PANEL IS OVER 6-0") SHUTTERS SHALL BE IN CONFORMANCE WITH AMERICAN PLYWOOD ASSOCIATIONS DESIGN #1 -SHUTTERS FOR WOOD FRAME BUILDINGS 9' CLG / MASTER BDRM l r° 2X8 RR 18" 0'C 16' l 2X4 CT OC 2Kefdsta 76' OC �l l 15'-6" DOUBLE CJ 2-2x10 3846 4,-8„ 15'-10" BATH Y x4se PLYWOOD HATCH IN 22"X32" FICkMED OPENING 52'-0" WITH DOUBLE CJ AND FRAMING HANGERS 3' v zeas AROUND OPENING FOR 30"X45" GLASS VENTING 3048 C ill MANUFACTURERS INSTALLATION INSTRUCTIONS, 3046 3046 2.2210 5' 6" 'v 4" 2.2x10 2X8 RR 16' °0 8 8 0 "' MASTER EATH e' cLG CLOSET 4 8'CLG to BEDROOM 2 zM 10'-0" m � � x 0 o / ¢ i l _ l j- 10'-4" WIND BORNE DEBRIS PROTECTION Areas within hurricane prone regions within one mile of the coastal mean high waterline where the basic wind speed is 110 miles per hour or greater, or where the basic wind speed is equal to or greater than 120 miles per hour shall have glazed openings protected from windbome debris. Glazed opening protection for Wridbome debris shall meet the requirements of the Large Missile Test of ASTM E 1996 and of ASTM E 1886 referenced therein. Wood structural panels with a minimum thickness of 7/16 inch and a maximum span of 8 feet shall be permitted for opening protection in one- and two-story buildings. Panels shall be precut to cover the glazed openings with attachment hardware provided. Attachments shall be provided In accordance with Table R301.2.1.2 or shall be designed to resist the components and cladding loads determined in accordance with the provisions of the Code HARDWARE: 2-112"#B SCREWS 16" O.C. (12" O.C. IF PANEL IS OVER 6-0") SHUTTERS SHALL BE IN CONFORMANCE WITH AMERICAN PLYWOOD ASSOCIATIONS DESIGN #1 -SHUTTERS FOR WOOD FRAME BUILDINGS 9' CLG / MASTER BDRM l r° 2X8 RR 18" 0'C 16' l 2X4 CT OC 2Kefdsta 76' OC �l l 15'-6" DOUBLE CJ 2-2x10 3846 4,-8„ 15'-10" BATH 3'-5" 5'-0" 52'-0" in 4" 3046 3046 2-2x10 6'-0" /4"[ BEDROOM 3 � e e CLOSET 5'4" 4" 6'4" l \ \ l 8' CLG BEDROOM 4 60 8 l ® \ c v c3 13'-2" \ 4" l 2.2x10 l/ 5'-0" 7'-11" 3046 3046 - _1 — 4 NICC�tii�s� • Y x4se PLYWOOD HATCH IN 22"X32" FICkMED OPENING Email: architect@oplonline.nel WITH DOUBLE CJ AND FRAMING HANGERS 3' v zeas AROUND OPENING FOR 30"X45" GLASS VENTING 4ee C ill MANUFACTURERS INSTALLATION INSTRUCTIONS, HALL 8° 3-2X10 FLUSH 8' CLG CJ HEADER LOCATIONS 2X8 RR 16' 2x4 CT 16' 2x6 CJ 16 OOPEN 142', CLG9'-4" SHELF 3'-5" 5'-0" 52'-0" in 4" 3046 3046 2-2x10 6'-0" /4"[ BEDROOM 3 � e e CLOSET 5'4" 4" 6'4" l \ \ l 8' CLG BEDROOM 4 60 8 l ® \ c v c3 13'-2" \ 4" l 2.2x10 l/ 5'-0" 7'-11" 3046 3046 - _1 — 4 NICC�tii�s� • R807 ATTIC ACCESS: WEATHER9TRIPED 3/4" oKIR-8-071 ATTIC PLYWOOD HATCH IN 22"X32" FICkMED OPENING Email: architect@oplonline.nel WITH DOUBLE CJ AND FRAMING HANGERS 1 DOUBLE ROOF RAFTERS WITH FRAMING HANGERS �I sKrLT. AROUND OPENING FOR 30"X45" GLASS VENTING R308.6 SKYLIGHT INSTALLED IN CONFORMANCE WITH ill MANUFACTURERS INSTALLATION INSTRUCTIONS, DETAILS AND SPECIFICATIONS. GLAZING TO CONFORM TO REQUIREMENTS FOR HAZARDOUS LOCATIONS R308 Glazing at hazardous locations shall have glazing protection in conformance with R308.In general, glazing in all doors & fixed side panels, Glazings less than 60" above surfaces of tubs, showers,etc. Glazing with In 24" arc of doors in closed position with sills less than 60" above floor. Glazings over 9 square feet and less than 1 B" above floor. Glazing near stainvaystiandings. See compleate text of R308.4 Glazing for specifics on locations and exceptions. R308.6 Skylights and sloped glazing shall comply with this section and have fully tempered glazing. R309 Garage opening protection and separation required to be as noted and in conformance with R309 .Garage floor surfaces shall be sloped to facilitate the movement of liquids to drain toward the main vehicle entry doorway. R310.1.1 All emergency escape and rescue openings shall have a minimum net clear opening of 5.7 square feet. 24" minimum clear opening height, 20" minimum clear opening width, 44" max sill height FINAL, INSTALLED STAIRWAYS ,HANDRAILS, GUARDS SHALL BE INSTALLED IN FULL COMFORMANCE WITH THIER RESPECTIVE CODE SECTIONS. ARCHITECT IS NOT RESPONSIBLE FOR THESE INSTALLATIONS. R314 Stairways shall not be less than 36 inches in clear width at all points above the permitted handrail height and below the required headroom height. Handrails shall not project more than 4.5 Inches on either side of the stairway and the minimum clear width of the stairway at and below the handrail height, including treads and landings, shall not be less than 31.5 inches where a handrail is installed on one side and 27 Inches where handrails are provided on both sides. The maximum riser height shall 8.25" and the minimum tread depth shall be 9" in conformance with R314.2. Minimum headroom 6'-8". All stairs shall be provided with Illuminatlonin accordance with Section R303.4. Enclosed accessible space under stairs shall have walls, under stair surface and any soffits protected on the enclosed side with 1/2 -inch gypsum board. R315.1 Handrails having minimum and maximum heights of 34 inches and 38 inches, respectively, measured vertically from the nosing of the treads shall be provided on at least one side of stairways. All required handrails shall be continuous the full length of the stairs with two or more risers from a point directly above the top riser of a flight to a point directly above the lowest riser of the fiight.Ends shall be returned or shall terminate In newel posts or safety terminals. Handrails adjacent to a wall shall have a space ofnot less than 1.5 inches (38mm)between thewall and the handrail. The handgrip portion of handrails shall have a circular cross section of 1-1/4 inches minimum to 2-5/8 Inches maximum. Edge radius of 1/8". R316.1 Guards are to be minimum 36 inches (914mm) in height. Open sides of stairs with a total rise of more than 30 Inches above the floor or grade below shall have guards (each side) not Iess than 34 Inches In height measured vertically from the nosing of the treads. (Second story guards are recomended to be higher.) R317.1 Single and multiple -station smoke alarms shall be Installed in each sleeping room, outside of each separate sleeping area In the immediate vicinity of the bedrooms,on each additional story of the dwelling, Including basements.The alarm devices shall be Interconnected in such a manner that the actuation of one alarm will activate all of the alarms in the Individual unit.The alarn shall be clearly audible In all bedrooms over background noise levels with all Intervening doors closed. All smoke alarms shall be listed and installed In accordance with the provisions of this code and the household firewaming equipment provisions of NFPA72. R319.1.2 Wall and calling finishes not including trim, door orwindow frames shall have a flame -spread classification of not greater than 200. Wall and ceiling finishes shall have a smoke -developed index of not greater than 450. R322.A vapor retarder shall be Installed on the warn -in -winter side of all Insulation. R1001.1 Masonry chimneys shall be constructed, anchored,supported and reinforced as required In this chapter and the applicable provisions of Chapters 3, 4 and 6 with applicable clearances to combustibles and firestoping. R807.1 Attic access. An attic access opening shall be provided to attic areas that exceed 30 square feet and have a vertical height of 30 Inches or greater.The rough -framed opening shall not be less than 22 Inches by30 Inches and shall be located in a hallway or other readily accessible location. A 30 -inch minimum unobstructed headroom in the attic space shall be provided at some point above the access opening. See Section M1305.1.3 for access requirements where mechanical equipments located in attics. R808.1 Combustible Insulation shall be separated a minimum of 3 inches from recessed lighting fixtures, fanmotors and other heat -producing devices or separated in accordance with the conditions stipulated in the fixtures listing. Recessed lighting installed in the building thermal envelope shall meet the requirements of Section N1101.3. i✓ric Nicosia AFUM,CT 414 Main Streel,Suite 203, Port Jefferson, N.Y. 11777 Telephone: (631) 928.4456. Fax: (631) 928-9543 Email: architect@oplonline.nel 1525 MILL PATH ROAD SOUTHOLD, N.Y. 5EGON7 FLOOR PLAN Job* 040170 Scale: 1/8"=1r-0" �_� Date: 6/7/04 By: E.N. Rev: 8.5 USE 20' RAFTER LENGTHS —in wnnF SECTION A -A ROOF RAFTERS TO RAFTERS AT RIDGE OUTLOOK/FLYING GABLES IF PROVIDED: NAIL ROOF SHEATHING WITH 8D NAILS 4" O.C. TO 4'-0" FROM GABLE END. USE HT7/RT7 HOLDOWN AT 2X6 LADDER FRAMING 16" O.C. BALLOON FRAME ALL GABLE END WALLS OR BLOCK/BRACE GABLE ENDS T( CEILING DIAPHRAM CONNECT RAFTER TO PLATES AND PLATES TO STUDS WHERE NOT ALIGINED WINDOW/DOOR HEADER STRAP EACH JACK STUD: 1-1/4" X 20 GA STRAP WITH (4) 8d NAILS EACH Emma AND USP MP4F OR SIMPSON LTP PLATE AT SILL TO BAND JOIST. 4-8d COMMON NAILS IN EACH END OF 1-1/4" X20 Ga. STRAP 16" O.0 OR 2X4 COLLAR TIES IN UPPER 1/3 OF ROOF 16" O.C. ROOF RAFTERS TO STUDS OR PORCH GIRDER 4-8d COMMON NAILS IN EACH END OF 1-1/4'X20 Ga. STRAP - OR - USP RT10 OR SIMPSON LTS16 -NAILS PER MANUFACTURER. STUDS TO -STUD 3 AT SECOND FLOOR 4-8d COMMON NAILS IN EACH END OF 1-1/4" X 20 Ga. STRAP. SIMILAR AT GABLE END WALLS STUDS TO BAND JOIST AND FOUNDATION 4-8d COMMON NAILS IN EACH END OF 1-1/4" X 20 Ga. STRAP 16" O.C., WRAP UNDER SILL OR USE USP MP4F OR SIMPSON LTP4 PLATE 32" O.C. 5/8" ANCHOR BOLTS 48" O.C. WITH 3"X3" SLOTED SQUARE WASHERS - USP/SIMPSON LBPS 5/8" FJ STRAPING TO BE GALVANIZED ASTM GRADE 33 MIN, FJ TYPICAL UPLIFT CONNECTIONS SCALE: 3/8"=1'-0" RIDGE CAP SHINGLES ON CONTINUOUS RIDGE VENT 2X10 RIDGE BOARD RR M I 11\3" MIN. LAP TYPICAL CONSTRUCTION ASSEMBLIES ROOF CONSTRUCTION: SHINGLES: 6 NAILS PER SHINGLE, ASPHALT ROOFING INSTALLATION IN CONFORMANCE WITH MANUFACTURERS INSTALLATION INSTRUCTIONS AND CODE WITH APPROVED UNDERLAYMENT, FLASHINGS, ACCESORIES SHEATHING: 7/16" APA RATED PLYWOOD, 8d NAILS AS PER NAILING SCHEDULE. NINUM GUTTER AND LEADERS ON 2X6" FASCIA BOARDS CONTINUOUS VENTED SOFFITS —�WALL CONSTRUCTION: `s VINYL SIDING ON TYVEK WITH m JOINT/WINDOW/DOORTAPE ON 7116" APA RATED STRUCTURAL SHEATHING E. FRAMING ON STUDS 16" O.C. SIDING TO BE INSTALLED IN CONFORMANCE WITH R704.5 `a ANCHORS TO MIN. LAP t9 LEDGERS rALUCEILING BOARD: 12" MIN. GYPSUM BOARD TAPED WITH 3 COATS SPACKLE. RIM BOARD iii �, ROOF TO HEADER HOEDOWNS 16" O.C. Soup _ PB4 HEADER TO COLUMN CAP- IGUARDS AND APPROVED HANDRAILS- SEE PLAN NOTES / PPT DECK/GIRDER/FOUNDATION. SEE PLAN NOTES ro 1COLUMN BOLTEDTHRU DECK JOIST 314" T80 PLYWOOD suBFLOOR, GLUE \ 12X4 HOEDOWN CLEAT 16" O.C. AND NAIL BOLTED CONNECTION - SEE PLAN NOTES —STOLID RIM i ARo g Mm I COLUMN BASEMOLDOWN: SIMPSON P94 BLOCKING TO 12" ANCHOR BOLT SILL CONSTRUCTION: 2X6 PRESSURE PRESERVATIVLY TREATED SILL ON SILL SEAT ON TERMITE SHIELD ANCHOR BOLTS AND HOLDOWNS PER FOUNDATION PLAN. POURED CONCRETE FOUNDATION WALLS ON CONTINUOUS, KEYED FOOTINGS BEARING ON UNDISTURBED SOIL. SEE FOUNDATION PLAN FOR WALLIFOOTING SIZES AND REBAR/ANCHOR BOLT INFORMATION DAMPROOFING OR WATERPROOFING AS REQUIRED BY R406. DRAINAGE SYSTEM IF REQUIRED BY SOIL CONDITIONS. TYPICAL CONSTRUCTION SECTION 4" P.C. SLAB. OPTIONAL VAPOR RETARDER ON COMPACTED SAND HVAC Equipment: Installed in conformance with Section 503, Boiler. 82 AFUE MIN Air Leakage: 502.1.4Joints, penetrations, and all other such openings In the building envelope that are sources of air leakage must be sealed as specified in 502.1.4.2. Recessed lights must be Type IC rated and installed with no penetrations sealed or Basketed to prevent air leakageinto the un-conditiond space.Vapor Retarder to be on the warm -in -winter side of allnon-vented cellings,walls & floors.1.0 pens max. Materials Identification: Matedals and equipment must be Identified so that compliance can be determined and must be Installed In accordance with the manufacturer's Installation Instructions and code. Duct Insulation to conform withSection 503 Fireplaces must be Installed with fight fitting non-combustible fireplace doors and must be provided with a source of combustion air, as required by the building code Service Water Heating to be Installed in conformance with Section 504. Insulate circulating hot water pipes to the levels in Table 1. Heating and Cooling Piping Insulation to conform with Section 503. 0='&1) 4 !ki=tel ILI 10100094' f eric Nicosia ARCHITECT 414 Main Street,Suite 203, Port Jefferson, N.Y. 11777 Telephone: (631) 928.4456. Fax: (631) 928-9543 Email: architect@optonline.net 1525 MILL PATH ROAD SOUTHOLD, N.Y. 5E0TI0N/RI5ER/ENERGY Job#: 040170 I Scale: 1/8"=1IA-6] Date: 617/04 By: E.N. I Rev: ENERGY REPORT: Compliance Is determined by use of The USDOE software approved by the secretary of VENTING TO BE IN CONFORMANCE state. The general provisions of the New York State Energy Conservation Construction WITH CHAPTER 31 -VENTS 3" MIN. VENTS THRU ROOF Code, Chapter 5, Sections 502,503,504 and 505, shall be met. 1•-1 5"MECcheck 1e--1.5" Compliance Report Construction Code New York State Energy Conservation WC MECcheck Software Version 3.5 Release 1 a COUNTY Suffolk, HDD:5750, TYPE: Detached 1 Family, HEATING:Non-Electric HOWER ��HOWER COMPLIANCE: Passes TUB Maximum UA= 447 Project UA = 322 Gross Glazing 4 FIXTURE BATH SHOWER BATH 5.6% Better Than Code Area or Cavity Cont. or Door 5 FIXTURE UNITS 5 FIXTURE UNITS Perimeter R -Value R -Value U -Factor UA Ceiling 1: Flat Ceiling. 1280 30.0 0.0 42 1F1,5" !_1.5" 1.5" Ceiling 2: Cathedral Ceiling 80 19.0 0.0 13 0.420 3 WC 1.25' " �" DWWASHER Skylight: Wd Frame, Dbl Pane 7 Wall 1: Wood Frame, 16" o.c. 2596 13.0 0.0 151 Window 1: Andersen Low E 308 0.340 82 STANDPIPE �22 Door 1: Andersen Low E 40 0.340 13 LAV NK .5 1 5" 3 2" Door 2: Solid-, partial glazing 55 0.220 6 3" Floor 1: Wood Joists 1290 19.0 0.0 65 3" 1/2 BATH KITCHEN WASHER Boiler 1: 82AFUE 4 FIXTURE UNITS 3 FIXTURE UNITS 1 FUCNRE UNITS FRESH COMPLIANCE STATEMENT: The proposed building represented in this document is AIR IN consistent with the building plans, specifications, and other calculations submitted with 3" WASTE 4" HOUSE DRAIN this permit application.The proposed systems have been designed to meet the — New York State Energy Conservation Construction Code requirements. CLEAN OUTS AS REQUIRED HOUSE TRAP BY SECTION P30052 ARCHITECTS SEAL, SIGNATURE AND DATE IN TITLE BLOCK 12" APPROVED COPPER 4" CAST IRON SLOPED TO SUPPLY LINES APPROVED SANITARY SYSTEM ENERGY NOTES: PLUMBING RISER DIAGRAM Ceiling l: Flat Ceiling R-30.0 cavity Insulation. Ventilation baffles. Ceiling 2: Cathedral Calling, R-19.0 cavity insulation. Ventilation baffles. SCHEMATIC - NO SCALE Well 1: Wood Frame, 16" o.c., R-13.0 cavity insulation Windows: U -tactor. 0.340: Andersen - Low E Glazing. Skylights: Wood Frame, Double Pane, U -factor. 0.420 Door 1: Glass, U -factor. 0.340:Andersen Dr. Door 2: Solid, U -factor. 0.220: Steel/Flberglass.Dr Floors: Floor 1:Wood Joist, Over Unconditioned Space, R-19.0 cavity Insulation 4-8d COMMON NAILS IN EACH END OF 1-1/4'X20 Ga. STRAP - OR - USP RT10 OR SIMPSON LTS16 -NAILS PER MANUFACTURER. STUDS TO -STUD 3 AT SECOND FLOOR 4-8d COMMON NAILS IN EACH END OF 1-1/4" X 20 Ga. STRAP. SIMILAR AT GABLE END WALLS STUDS TO BAND JOIST AND FOUNDATION 4-8d COMMON NAILS IN EACH END OF 1-1/4" X 20 Ga. STRAP 16" O.C., WRAP UNDER SILL OR USE USP MP4F OR SIMPSON LTP4 PLATE 32" O.C. 5/8" ANCHOR BOLTS 48" O.C. WITH 3"X3" SLOTED SQUARE WASHERS - USP/SIMPSON LBPS 5/8" FJ STRAPING TO BE GALVANIZED ASTM GRADE 33 MIN, FJ TYPICAL UPLIFT CONNECTIONS SCALE: 3/8"=1'-0" RIDGE CAP SHINGLES ON CONTINUOUS RIDGE VENT 2X10 RIDGE BOARD RR M I 11\3" MIN. LAP TYPICAL CONSTRUCTION ASSEMBLIES ROOF CONSTRUCTION: SHINGLES: 6 NAILS PER SHINGLE, ASPHALT ROOFING INSTALLATION IN CONFORMANCE WITH MANUFACTURERS INSTALLATION INSTRUCTIONS AND CODE WITH APPROVED UNDERLAYMENT, FLASHINGS, ACCESORIES SHEATHING: 7/16" APA RATED PLYWOOD, 8d NAILS AS PER NAILING SCHEDULE. NINUM GUTTER AND LEADERS ON 2X6" FASCIA BOARDS CONTINUOUS VENTED SOFFITS —�WALL CONSTRUCTION: `s VINYL SIDING ON TYVEK WITH m JOINT/WINDOW/DOORTAPE ON 7116" APA RATED STRUCTURAL SHEATHING E. FRAMING ON STUDS 16" O.C. SIDING TO BE INSTALLED IN CONFORMANCE WITH R704.5 `a ANCHORS TO MIN. LAP t9 LEDGERS rALUCEILING BOARD: 12" MIN. GYPSUM BOARD TAPED WITH 3 COATS SPACKLE. RIM BOARD iii �, ROOF TO HEADER HOEDOWNS 16" O.C. Soup _ PB4 HEADER TO COLUMN CAP- IGUARDS AND APPROVED HANDRAILS- SEE PLAN NOTES / PPT DECK/GIRDER/FOUNDATION. SEE PLAN NOTES ro 1COLUMN BOLTEDTHRU DECK JOIST 314" T80 PLYWOOD suBFLOOR, GLUE \ 12X4 HOEDOWN CLEAT 16" O.C. AND NAIL BOLTED CONNECTION - SEE PLAN NOTES —STOLID RIM i ARo g Mm I COLUMN BASEMOLDOWN: SIMPSON P94 BLOCKING TO 12" ANCHOR BOLT SILL CONSTRUCTION: 2X6 PRESSURE PRESERVATIVLY TREATED SILL ON SILL SEAT ON TERMITE SHIELD ANCHOR BOLTS AND HOLDOWNS PER FOUNDATION PLAN. POURED CONCRETE FOUNDATION WALLS ON CONTINUOUS, KEYED FOOTINGS BEARING ON UNDISTURBED SOIL. SEE FOUNDATION PLAN FOR WALLIFOOTING SIZES AND REBAR/ANCHOR BOLT INFORMATION DAMPROOFING OR WATERPROOFING AS REQUIRED BY R406. DRAINAGE SYSTEM IF REQUIRED BY SOIL CONDITIONS. TYPICAL CONSTRUCTION SECTION 4" P.C. SLAB. OPTIONAL VAPOR RETARDER ON COMPACTED SAND HVAC Equipment: Installed in conformance with Section 503, Boiler. 82 AFUE MIN Air Leakage: 502.1.4Joints, penetrations, and all other such openings In the building envelope that are sources of air leakage must be sealed as specified in 502.1.4.2. Recessed lights must be Type IC rated and installed with no penetrations sealed or Basketed to prevent air leakageinto the un-conditiond space.Vapor Retarder to be on the warm -in -winter side of allnon-vented cellings,walls & floors.1.0 pens max. Materials Identification: Matedals and equipment must be Identified so that compliance can be determined and must be Installed In accordance with the manufacturer's Installation Instructions and code. Duct Insulation to conform withSection 503 Fireplaces must be Installed with fight fitting non-combustible fireplace doors and must be provided with a source of combustion air, as required by the building code Service Water Heating to be Installed in conformance with Section 504. Insulate circulating hot water pipes to the levels in Table 1. Heating and Cooling Piping Insulation to conform with Section 503. 0='&1) 4 !ki=tel ILI 10100094' f eric Nicosia ARCHITECT 414 Main Street,Suite 203, Port Jefferson, N.Y. 11777 Telephone: (631) 928.4456. Fax: (631) 928-9543 Email: architect@optonline.net 1525 MILL PATH ROAD SOUTHOLD, N.Y. 5E0TI0N/RI5ER/ENERGY Job#: 040170 I Scale: 1/8"=1IA-6] Date: 617/04 By: E.N. I Rev: 10'-4" 52'-0" 10'-6" 4".. 2'-0"_..4" 5'-0" --II 3048 3046 —1I 4" '-3" V-3" I BATH 8'CLG Up CLOSET 4 0f�8 � � OJ �i SKYLT. BEDROOM 2 i NI R308.6 M 26W N A _ F 12'-10" \8 9'CLG / MASTER BDRM 2X8 RR 16" O.0 2X4 CT 16" OC A iAo 16'aC 15'-6" DOUBLE CJ 2 2x10 — 3846 2'-0" 4'-8" � v 2466 2666 14ea cc 12'-10" ® 3-2X10 FLUSH. HALL CJ HEADER 8' CLG — 2em-- N— 3'-2" 12'-4" 3046 3046 2-2x10 6'-0" m 8'CLG / C'i O UO BEDROOM 3 it \ R807 ATTIC ACCESS: WEATHERSTRIPED 3W' 2x8 RR 16" O.0 2X4 CT 16" OC _ 3046 L m 2-2x10 0" 5'-6" U, SIX- g q / MASTER ATH u x °v 8' CLG / m / \ 2-200N Co — CTit _ 10,_0„ � p -6°I 10'-4" 52'-0" 10'-6" 4".. 2'-0"_..4" 5'-0" --II 3048 3046 —1I 4" '-3" V-3" I BATH 8'CLG Up CLOSET 4 0f�8 � � OJ �i SKYLT. BEDROOM 2 i NI R308.6 M 26W N A _ F 12'-10" \8 9'CLG / MASTER BDRM 2X8 RR 16" O.0 2X4 CT 16" OC A iAo 16'aC 15'-6" DOUBLE CJ 2 2x10 — 3846 2'-0" 4'-8" � v 2466 2666 14ea cc 12'-10" ® 3-2X10 FLUSH. HALL CJ HEADER 8' CLG — 2em-- N— 3'-2" 12'-4" 3046 3046 2-2x10 6'-0" m 8'CLG / C'i O UO BEDROOM 3 it \ R807 ATTIC ACCESS: WEATHERSTRIPED 3W' 2x8 RR 16" O.0 2X4 CT 16" OC _ 1 11 �o L m 1 i o U, SIX- g MR c u x °v :o / m / M 2-200N \ �2 — CTit _ IV OPEN BELOW 10'-4" 52'-0" 10'-6" 4".. 2'-0"_..4" 5'-0" --II 3048 3046 —1I 4" '-3" V-3" I BATH 8'CLG Up CLOSET 4 0f�8 � � OJ �i SKYLT. BEDROOM 2 i NI R308.6 M 26W N A _ F 12'-10" \8 9'CLG / MASTER BDRM 2X8 RR 16" O.0 2X4 CT 16" OC A iAo 16'aC 15'-6" DOUBLE CJ 2 2x10 — 3846 2'-0" 4'-8" � v 2466 2666 14ea cc 12'-10" ® 3-2X10 FLUSH. HALL CJ HEADER 8' CLG — 2em-- N— 3'-2" 12'-4" 3046 3046 2-2x10 6'-0" m 8'CLG / C'i O UO BEDROOM 3 it \ R807 ATTIC ACCESS: WEATHERSTRIPED 3W' 2x8 RR 16" O.0 2X4 CT 16" OC _ 1 11 �o L 2X6 CJ 16 OC 1 i DOUBLE ROOF RAFTERS WITH FRAMING HANGERS Job#:040170 Scale: 1/8"=1'-0" Z c SKYLIGHT INSTALLED IN CONFORMANCE WITH :o MANUFACTURERS INSTALLATION INSTRUCTIONS, DETAILS AND SPECIFICATIONS. GLAZING TO M LOCATIONS \ �2 OPEN BELOW o `too 9' CLG U 4" 9'-4" \ 4" 2' 0" 4" SHELF \ — _ -2-200 7 15'-10" 10'-0" 41'-8" 52'-0" WINDOWS SHOWN PROVIDE MORE THAN 8% LIGHT & 4 %VENTILATION FOR ROOMS IN CONFORMANCE WITH REQUIREMENTS OFR303.1 WINDOWS ARE SHOWN AS ANDERSEN 400 SERIES TILTWASH WITH LOW E GLAZING. VERIFY ALL QUANTITIES, ROUGH OPENINGS, MULLIONS, TEMPERED GLASS LOCATIONS BEFORE ORDERING WINDOWS/DOORS AND BEFORE FRAMING OPENINGS. MINIMUM DESIGN PRESSURE FOR WINDOWS AND MULLIONS = DP30 EXTERIOR DOOR ASSEMBLIES TO HAVE A MINIMUM DESIGN PRESSURE RATING = DP30. WIND BORNE DEBRIS PROTECTION Areas within hurricane prone regions within one mile of the coastal mean high water line where the basic wind speed is 110 miles per hour or greater, or where the basic wind speed Is equal to or greater than 120 miles per hour shall have glazed openings protected from windbome debris. Glazed opening protection for windbome debris shall meet the requirements of the Large Missile Test of ASTM E 1996 and of ASTM E 1886 referenced therein. 1609.1.4 - EXCEPTION - for use of plywood panels as follows Wood structural panels with a minimum thickness of 7/16 Inch and a maximum span of 8 feet shall be permitted for opening protection in one- and two-story buildings. Panels shall be precut to cover the glazed openings with attachment hardware provided. Attachments shall be provided in accordance with Table R301.2.1 2 or shall be designed to resist the components and cladding loads determined In accordance with the provisions of the Code HARDWARE: 2-12" #8 SCREWS 16" O.C. (12" O.C. IF PANEL IS OVER 6'-0") SHUTTERS SHALL BE IN CONFORMANCE WITH AMERICAN PLYWOOD ASSOCIATIONS DESIGN#1-SHUTTERS FOR WOOD FRAME BUILDINGS T-1 Y' CLOSET 5'-4" 4" 6'-4" '8' CLG UU BEDROOM 4 ° ° o m \ oni G i33 13,_2" \ 2-2x10 4" 3046 3046 15,_10,• T-11 4 ti N a i Re- R807 ATTIC ACCESS: WEATHERSTRIPED 3W' Arrlc PLYWOOD HATCH IN 22"X32" FRAMED OPENING L WITH DOUBLE CJ AND FRAMING HANGERS 1 i DOUBLE ROOF RAFTERS WITH FRAMING HANGERS Job#:040170 Scale: 1/8"=1'-0" AROUND OPENING FOR 30"X45" GLASS VENTING I R308.8 SKYLIGHT INSTALLED IN CONFORMANCE WITH I MANUFACTURERS INSTALLATION INSTRUCTIONS, DETAILS AND SPECIFICATIONS. GLAZING TO CONFORM TO REQUIREMENTS FOR HAZARDOUS LOCATIONS PLAN REFERENCE NOTES R308 Glazing at hazardous locations shall have glazing protection In conformance with R308.In general, glazing in all doors & fixed side panels, Glazings less than 60" above surfaces of tubs, showers,etc. Glazing with in 24" arc of doors in closed position with silts less than 60" above floor. Glazings over 9 square feet and less than 18" above floor. Glazing near stairways/lani ings. See compieate text of R308.4 Glazing for specifics on locations and exceptions. R308.6 Skylights and sloped glazing shall comply with this section and have fully tempered glazing. R309 Garage opening protection and separation required to be as noted and In conformance with R309 .Garage floor surfaces shall be sloped to facilitate the movement of liquids to dram toward the main vehicle entry doorway. R310.1.1 AN emergency escape and rescue openings shall have a minimum net clear opening of 5.7 square feet. 24" minimum dear opening height, 20" minimum clear opening width, 44" max sill height. FINAL, INSTALLED STAIRWAYS ,HANDRAILS, GUARDS SHALL BE INSTALLED IN FULL COMFORMANCE WITH THIER RESPECTIVE CODE SECTIONS. ARCHITECT IS NOT RESPONSIBLE FOR THESE INSTALLATIONS. R314 Stairways shall not be less than 36 Inches in dear width at all points above the permitted handrail height and below the required headroom height. Handrails shall not project more than 4.5 Inches on either side of the stairway and the minimum dearwidth of the stairway at and below the handrail height, including treads and landings, shall not be less than 31.5 Inches where a handrail Is installed on one side and 27 inches where handrdOs are provided on both sides. The maximum riser height shell 8.25" and the minimum tread depth shall be 9" In conformance with R314.2. Minimum headroom 6-8". All stairs shall be provided with Illuminationin accordance with Section R303.4. Enclosed accessible space under stairs shall have walls, under stair surface and any soffits protected on the enclosed side with 1/2 -inch gypsum board. R315.1 Handrails having minimum and maximum heights of 34 Inches and 38 Inches, respectively, measured vertically from the nosing of the treads shell be provided on at least one side of stairways. All required handralls shall be continuous the full length of the stairs with two or more risers from a point directly above the top riser of a flight to a point directly above the lowest riser of the flighLEnds shall be returned or shall terminate in newel posts or safety terminals. Handrails adjacent to a wall shall have a space ofnot less than 1.5 inches (38mm)between thewall and the handrail. The handgrip portion of handrails shall have a circular cross section of 1-1/4 inches minimum to 2-5/8 Inches maximum. Edge radius of 1/8". R316.1 Guards are to be minimum 36 inches (914mm) In height Open sides of stairs with a total rise of more then 30 Inches above the floor or grade below shell have guards (each side) not less than 34 inches in height measured vertically from the nosing of the treads. (Second story guards are recomended to be higher.) R317ASingle and multiple -station smoke alarms shall be Installed in each sleeping room, outside of each separate sleeping area in the Immediate vicinity of the bedrooms,on each additional story of the dwelling, Including basements.The alarm devices shall be Interconnected in such a manner that the actuation of one alarm will activate all of the alarms in the individual unit.The alarm shall be clearly audible In all bedrooms over background noise levels with all intervening doors closed. All smoke alarms shall be listed and installed In accordance with the provisions of this code and the household firewaming equipment provisions of NFPA72. R319.1.2 Wall and ceiling finishes not including trim, door or window frames shall have a flame -spread classification of not greater than 200. Wall and ceiling finishes shall have a smoke -developed index of not greater than 450. R322.A vapor retarder shall be installed on the wane -in -winter side of all Insulation. R1001.1 Masonry chimneys shall be constructed, anchored,supported and reinforced as required in this chapter and the applicable provisions of Chapters 3, 4 and 6 with applicable clearances to combustibles and flrestoping. R807.1 Attic access. An attic access opening shall be provided to attic areas that exceed 30 square feet and have a vertical height of 30 inches or greater.The rough -framed opening shall not be less then 22 inches by30 Inches and shall be located In a hallway or other readily accessible location. A 30 -Inch minimum unobstructed headroom in the attic space shall be provided at some point above the access opening. See Section M1305.1.3 for access requirements where mechanical equipmentis located in attics, R808.1 Combustible insulation shall be separated a minimum of 3 inches from recessed lighting fixtures, fanmotors and other heat -producing devices or separated in accordance with the conditions stipulated In the fixtures listing. Recessed lighting Installed in the building thermal envelope shall meet the requirements of Section N1101.3. Brie Nicosia WHITEGT 414 Main Slreet,Suite 203, Port Jefferson, N.Y. 11777 Telephone: (631) 928-4456. Fax: (631) 928.9543 ' Email: architect®optonline.net 1825 MILL PATH ROAD SOUTHOLD, N.Y. 5EGOND FLOOR PLAN Job#:040170 Scale: 1/8"=1'-0" —5 Date: 7/25/04 By: E.N. ReV:A