Loading...
HomeMy WebLinkAbout31809-Z FORM NO. 4 TOWN OF SOUTHOLD BUILDING DEPARTMENT Office of the Building Inspector Town Hall Southold, N.Y. CERTIFICATE OF OCCUPANCY liIo: Z-33048 Date: OS/28/08 THIS CERTIFIES that the building FIRE PROTECTION SYS. (STREET) Block 2 PECONIC (HAMLET) Location of Property: 37325 MAIN RD (HOUSE NO.) County Tax Map liIo. 473889 Section 85 Lot 14 Subdivision Filed Map liIo. Lot liIo. conforms substantially to the Application for Building Permit heretofore filed in this office dated FEBRUARY 15, 2006 pursuant to whicb Building Permit liIo. 31809-Z dated FEBRUARY 24, 2006 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is FIRE PROTECTION SYSTEM TO AN EXISTING BUILDING AS APPLIED FOR. The certificate is issued to PINDAR ASSOCIATES (OWNER) of the aforesaid building. SUFFOLK COIJlllTY DEPARTMBHT OF HEALTH APPROVAL N/A ELECTRICAL CERTIFICATE NO. N/A PLUMBERS CERTIFICATION DATED Authorized Signature Rev. 1/81 , Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: I. Final survey of property with accurate location of all buildings, property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/1 0 of I % lead. 5. Commercial building, industrial building, multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings (prior to April 9,1957) non-conforming uses, or buildings and "pre-existing" land uses: I. Accurate survey of property showing all property lines, streets, building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied, the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees I. Certificate of Occupancy - New dwelling $25.00, Additions to dwelling $25.00, Alterations to dwelling $25.00, Swimming pool $25.00, Accessory building $25.00, Additions to accessory building $25.00, Businesses $50.00. 2. Certificate of Occupancy on Pre-existing Building - $100.00 3. Copy of Certificate of Occupancy - $.25 4. Updated Certificate of Occupancy - $50.00 5. Temporary Certificate of Occupancy - Residential $15.00, Commercial $15.00 6.(;(\.08 Date. Location of Property: (check one) New Construction: House No. Owner or Owners of Property: 2; ~\ 'In Q Street -A08()c;oe~ D ~? Block ncJ) .c;< Hamlet Suffolk County Tax Map No 1000, Section Lot~\Y Date of Permit.':? J6NJd..,p . Filed Map. Lot: Applicant: ~;(lc\n\ ~~C\()k~ Subdivision Permit No. S\ 8'OGtz. Underwriters Approval: /(CheC Health Dept. Approval: Planning Board Approval: Request for: Temporary Certificate Fee Submitted: $ :::50.00 60--2 ?3D~2s {Zo C- {~2>~~ Final Certificate: FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 31809 Z Date FEBRUARY 24, 2006 Permission is hereby granted to: PINDAR ASSOCIATES 591 BICYCLE PATH-SUITE A PORT JEFFERSON STA,NY 11776 for : INSTALLATION OF A FIRE PROTECTION SYSTEM AS APPLIED FOR at premises located at 37325 MAIN RD PECONIC County Tax Map No. 473889 Section 085 Block 0002 Lot No. 014 pursuant to application dated FEBRUARY 15, 2006 and approved by the Building Inspector to expire on AUGUST 24, 2007. Fee $ 200.00 /~. ~ I cL . _ . Authorized Signature ORIGINAL Rev. 5/8/02 ~~ .~_.:-~ - -'''''-...c;-.--.. ). (~ c 11' lJ'\)AQ. .,~~ t5Lu6 ~1" ::#= :!;,\g'DCj TOWN OF SOUTH OLD BUILDING DEPT. 765.1802 INSPECTION [ ] FOUNDATION 1 ST [] ROUGH PLBG. [ ] FOUNDATION 2ND [] INSULATION [ ] FRAMING I STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION Cf?e\\~1 ~, DATEL:\ - \2- - O&y FIELD INSPECTION REPORT DATE COMMENTS \)J..., - /"l c/1 ~ FOUNDATION (lSn ,,- . .., '"' "" ------------------------------------ . ~.\:: ~, ..... rI:l FOUNDATION (2ND) . r\ /"l :) l' Z r " p ~ o. 5 ell .., f;J ROUGH FRAMING & /"l PLUMBING \)J'" -J \Y Y JI t ~~ :':>t- /"l INSULATION PER N. Y. "'N"'l STATE ENERGY CODE - - ~ n __ C', C . -' ~. FINAL ..- . " . ADDITIONAL COMMENTS -1 4-12 -Ob l..-'- :f1 D: ''''' ';"'1\ .J.r.,ST~ o/r1 CN TO ~f CrtZ-T1F/~ C) tll2-(" lrz.A-r4n IE$I ;13,E!\7hS \ tAr s- \)0 LLS -- ~I-"'Ss.c.-~ 1.1. ::v CEiV7t:1LAL S,A'1lo;J ~A- .1l b .1. nr\ r.c~I ~c7 IV ('1,[ .Q'';'"u; f..'t4 fj 0 :E T::>. :+l ~ Me. (',xL-'en nu<<md"'-. ~ =f, (t ~ z 4-/3- vi=> ~m ,vI\, ;0 .--rin '- \S '-'.":.'A'::>0 \=0(2... W. WI'n "\ 0>-J>\L "YI f'r. 0-> V I i', , i'1:,0\L-"~( I S Cc.J -d c I.Y--; , E;-/9- 0'8 lV'o UN )Y:i-~IC-t ~"02.-.s. c <c--fl.:f tZ-t-zL PiJIL. ! n~ A1. .a, / ,liS /kt..LA-TJ tII--) ,// J, yf L.../J c:/! /"l .iJ :>< ..., r - , ~ c:: .., ---i - 0 Z == 1/-. /"l r--- ~ ., -\--' == I:l /"l ." ~ TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL FEBI, SOUTHOLD, NY 11971. I TEL: (631) 765-1802 I l .. . _.~ FAX: (631) 765-9502 :.._-1'.. ~.' " ,lLD www.northfork.net/Southoldl PERMIT NO:'- ~-I J'V if . , , I' BUILDING PERMIT APPLICATION CHECKLIST ,i;; Do you have or need the following, before applying') Board of Health 4 sets of Building Plans Planning Board approval Survey Check Septic Form N.Y.S.D.E.C. Trustees Contact: I' Examined dl~i ,20 of, '1 J-'f ' 20ID fa Approved Disapproved ale Mail to: Phone: Expiration ~ /Y(',20J[1 I APPLICATION FOR BUILDING PERMIT Date I liD / ,20 Db INSTRUCTIONS , a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 set's of plans, accurate plot plan to scale. Fee according to schedule. b. Plot plan showing location oflot and of buildings on premises, relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application, the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e. No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim, the Building Inspector may authorize, in writing, the extension of the permit for an addition six months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of South old, Suffolk County, New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances, building code, housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. l?.$,?L/~I/1I~2:n C;,m/1?"p,p1U'f)~5 lA/G' (Signature of applicant or name, if a corporation) rfJSOWv./1?7f ~ ~c; I 5/1_ /t/'f;/ft,f (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder ~~ #~ ;;:;;;5/9?-rL-//Zeb C?/??~ ",.75'. J./C/ rI= /c?-(}tJVCJ/;?-7~O Name of owner of premises (As on the tax roll or latest deed) If applicant is a corporati re of duly authorized officer d t/, l:. (Name and title of corporate 0 flcer) Builders License No. Plumbers License No. Electricians License No. Other Trade's License No. / ;;()Cf.C?/;;;' 7 i 0 1. Location of land on w~ich propo ed I House Number ork will be done: IC.- Hamlet Street County Tax Map No. 1000 Section Subdivision 'i <;" ~ Block J.- I:r" Filed Map No. ,.. Lot )1"1 Lot .J (Name) -.--,. " "'~ 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy ~. , ">, " b. Intended use and occupancy , VJlne....- S'f'v r-o..J~ Addition Other Work f,J~ lvDu);;e J 3. Nature of work (check which applicable): New Building Repair Removal Demolition F,(!..f3;. t;;;kon dro'\ (Description) 'S7S. 4. Estimated Cost Fee 5. If dwelling, number of dwelling units If garage, number of cars (To be paid on filing this application) Number of dwelling units on each floor 6. Ifbusiness, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front ~ <) 0 Height Number of Stories Rear 1-<;0 Depth 3D Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction: Front Height Number of Stories Rear Depth 9. Size oflot: Front Rear Depth t 10. Date of Purchase Name of Former Owner II. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation? YES_NO_ 13. Will lot be re-graded? YES_NO_ Will excess fill be removed from premises? YES_ NO_ Phone No. Phone No Phone No. Address Address Address 14. Names ofOwl)erofpremises . Name of Architect Name of Contractor 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES _NO _ * IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES_NO_ * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. STATE OF NEW YORK) SS: COUNTY O~(1~LU 'Sf-AN 1< au (7 H 4 i\l being duly sworn, deposes and says that (s)he is the applicant (Name of individual signing contract) above named, ArJt EN r (Contractor, Agent, Corporate Officer, etc.) (S)He is the of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. 2006 ~ -II Notary ~ubl c MELANIE DOROSKl NOTARV PUBLIC, State of New~ No 01 C04634870 Qualified in Suffolk CountY ......1Y\L \:ommission Expires September 3~ Town Hall, 53095 Main Road P.O. Box 1179 Southold, New York 11971-0959 Fax (631) 765-9502 Telephone (631) 765-1802 J BUILDING DEPARTMENT TOWN OF SOUTHOLD Fire & Safety Inspection Revort 2004 June 3, 2004 Mr. Jason Damianos Pindar Winery 37295 Main Road Peconic, NY 11958 Dear Mr. Damianos: Thank you for the cooperation during the fire inspection of Pindar Winery on June 1, 2004. The maximum occupancy of your establishment is 136. This figure is shown on the enclosed occupancy certificate. This certificate supercedes all previous certificates and is valid for one year from the indicated date. If the occupancy indicated is 50 or higher this certificate shall be posted in a conspicuous location near the main entrance to your establishment. The additional certificate shall be posted in the tasting room. New and existing buildings shall have building numbers placed in a position to be plainly legible from the street or road fronting the property. The numbers shall be a minimum of 4 inches high. Your building number is 37295. During the inspection the following violations were noted and should be corrected immediately. Winery The fire alarm and life safety systems shall be maintained in an operable condition at all times. The fire and life safety systems shall be properly inspected and tested annually. A written record shall be maintained and shall be made available to the code enforcement official for a minimum of 2 years. Pindar-04-06-1 85-2-14,15 Page 1 The unused components of the old alarm system shall be removed. If alarm components are installed the parts must function properly. All emergency lights must be in proper operating condition at all times. One set in the tasting room did not work properly. Open junction boxes and Open-wiring splices shall be prohibited. Approved covers shall be on all switch and electrical outlet boxes. There were open boxes on the first floor and in the basement. The building shall be properly placarded for hazardous materials. Maximum storage of sulfur dioxide is 810 cubic feet. Each gas tank contains between 300 and 330 cubic feet. The numbers on the placard should be Health 3, Fire 0, reactivity 0, and no water used. See enclosed information. In the event that the stored amount exceeds 810 cubic feet, the storage area will be deemed a hazardous materials storage area and will be required to be separated, protected, and alarmed. The liquid propane tanks shall be stored outside or in another location. Fire extinguishers shall be inspected monthly by a designated employee and inspected and tagged yearly by an approved servicing company. The extinguisher in the office was discharged and another extinguisher was not properly tagged. A handrail is necessary on the other side of the stairs to the basement. Storaqe Buildinq Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of extinguishers. More fire extinguishers are required. Extinguishers shall be located so that travel distance to an extinguisher is less than 75 feet. The building shall be properly placarded for hazardous materials. Maximum storage of sulfur dioxide is 810 cubic feet. Each gas tank contains between 300 and 330 cubic feet. The numbers on the placard should be Health 3, Fire 0, reactivity 0, and no water used. See enclosed information. In the event that the stored amount exceeds 810 cubic feet, the storage area will be deemed a hazardous materials storage area and will be required to be separated, protected, and alarmed. The liquid propane tanks shall be stored outside or in another location. Pindar-lJ4-lJ6-1 85-2-14, 15 Page 2 Electrical panels need to be open for inspection. Open junction boxes and Open-wiring splices shall be prohibited. Approved covers shall be on all switch and electrical outlet boxes. Certification of non-flammability for the vapor barrier is required. In addition the following are necessary for a Certificate of occupancy. 1. The fire area or areas need to be certified or corrected. The fire area is too large. 2. The building uses need to be certified as they relate to the building construction and occupancy separations. 3. As built plans are required. 4. The building and plans shall be reviewed to be sure that both adhere to the applicable state and local codes. 5. Final building inspection. 6. Final fire inspection. I will inspect again in about four weeks for compliance. If you have any questions or the required modifications are completed, please contact me at the above office or by emaiI.Myaddressisrobert.fisher@town.southold.ny.us. Ene: Fire Inspection Survey (2) Occupancy Certificate (2) Hazardous Materials Information Cc: Chief, Southold Fire Department Pindar -04-06-1 85-2-14,15 Page 3 KENNETH L. EDWARDS MARTIN H. SIDOR GEORGE D. SOLOMON JOSEPH L. TOWNSEND MAIliNG ADDRESS: P.O. Box 1179 Southold, NY 119711 OFFICE WCAll0N: Town Hall Annex 54375 State Route 25 (cor. Main Rd. & Youngs Ave.l Southold, NY Telephone: 631 765-1938 FIIlC 631 765-3136 PLANNING BOARD MEMBERS JERlLYN B. WOODHOUSE Chair January 24, 2007 PLANNING BOARD OFFICE TOWN OF SOUTHOLD Dr. Herodotus Damianos Pindar Vineyards 591ABigde Path Port JeffeISon Station, New York l1n6 Re: Pindar Vineyards Storage Building 37325 NYS Road 25, Peconic SCIM#: 1000-85-2-14 Dear Mr. Damianos: At the written request of Alexander Damianos, dated January 17, 2007, requesting final site plan inspection, Planning Department staff perfonned a site visit on January 19, 2007. In reference to the above, the Planning Board held a work session on January 22,2007 to discuss the approved site plan prepared by Clarles W. Southard dated May 12, 2001 and last revised January 3, 2007, the resolution dated January 9, 2007 and staff site visit conunents regarding the above referenced site plan. In reference to the above, the Planning Board has detennined the site plan requirements have been satisfied and include the following items: · All handicap parking stalls, access aisles and signage must comply with New York State Gxle and ADA requirements. This letter does not condone any changes from the as-built site plan and approvals from other agencies if required. Respectfully yours, C-~~.W~ Je~yn B. W~ouse Otairperson Cc: File Building Department Town Engineer FOR INTERNAL USE ONLY I rr,') ,f<L:n; (f,~'~- r~ ~ I "" SITE PLAN USE DETERMINATION/ill: N()V I 32006 Initial Determination 1_--, Date II / /3 / t Project Name:2c!a I? J2"'(V/~"S, 'ii.!,. Date Sent: II I 13 / .6 Project Address:S13';;1:,) IYJP-tN i1 . PUtJ;1/C , Suffolk County Tax Map No,:1 000- 'if s - c:7 -l.!:!- Zoning District: Ac ~~~e}~1:::ncPz;;f-7d5 f;J lftj, ;;~ffair' 7;:~:;:-ed4-P (Note: Copy of Building Permit Application and supporting documentation as to proposed use or uses should be submitted.) Initial Determination as to whether use is permitted: 1/.5'1" O.t?Y/t4~ I Initial Determination as to whether site plan is required: ~ f?h- rr'liUlrJ {) -- Si9"'tQi"~ Planning Department (P.O.) Referral: P,D, Date Received: / / / /? / tJ-G. "n.,"'" , .~"c,,~ ,....:"'~.: ..' ,.-"'.. ',.., .'.'.. '.',. ,>'c~'i Date of commJQt:'\'~/I\'IY2,'.~; 1\. \r'---"~ ,I , :j ,,",,,,.~~- ,~ ..~ , \ '< , , "'~,- }."" ,;'1'1, Final Determination Date: 1/ / It / /)c, Decision: ~ ~ ~ ~c..~ ,r.-~' ~ , Si~~~' --- 31 'gO 1 - TOWN OF SOUTHOLD - FIRE INSPECTORS OFFICE - TOWN HALL - MAIN ROAD - PO Box 1179 - SOUTHOLD, NEW YORK 11971 631-765-1802 ex!. 5028 ANNUAL CERTIFICATION OF INSPECTION AND TESTING FIRE ALARM SYSTEM CAUTION: NOTIFY ALL OCCUPANTS AND ANY AGENCIES WHO MIGHT RESPOND BEFORE TESTING SYSTEM. FAILURE TO DO SO MAY RESULT IN LEGAL ACTION AGAINST THE INSPECTOR. PLEASE PRINT ALL INFORMATION NAME OF PREMISES: hAh)A/:) MAI$1tcf I;'77?/Zm'.E' 7it,,/~..v6 ADDRESS OF PREMISES: 'J) SJ.-S ~Q(/'rt?'"" ;:}.J- FIRE DISTRICT: C'I/JC#I)~II~ NAME OF OWNER OR AGENT PRESENT: Jft5/)A} ':D~.//9A/OS TYPE OF SYSTEM NrOJ?1t'TIIC-- DOES SYSTEM REPORT TO CENTRAL STATION? YFS (MANUAL, AUTOMATIC, VOICE EVACUATION, ETC.) liST ALL DEFICIENCIES NOTED: 1Y/4 . WERE ALL DEFICIENCIES NOTED ABOVE CORRECTED? IF NOT, WHY: NAME OF INSPECTING FIRM: I3E,'-~_l2/fI/(?EJe.... &/J?/J1 t/,////C/?-/V;t/> ./tVc.. ADDRESS OF INSPECTING FIRM: c?3D Uv#7}' 2?~..:set ,)&Vi77'/7;?)O)t)p / IVV NYS ALARM LICENSE NUMBER: /.:J.a!:r}O /a. 7#/0 EXPIRATION DATE: 3 J;. 7 j,?p PHONE NUMBER OF INSPECTING FIRM: ~-sq()O DATE OF INSPECTION: ~//:z../6'G Certification: I, an employee of the Inspecting Firm listed above, do hereby certify that the Alarm System described above was inspected in accordance with the applicable portions of NFPA 72 (1999 version), particularly Chapter 7 as well as Table 1004.3 & Section 10.6.2 of NFPA 72. This certification does not imolv that items requiring daily, weekly, monthly, or quarterly inspection or testing were performed at the specified intervals, but does imolv all such items were inspected or tested and appear to function as noted in this certification at the time of inspection. I certify that this inspection has been properly conducted and all of the above statements are true and correct to the best of my knowledge. .~ 4~rJ'f.er.J- 'D~.L ::Ry o/~;L/~ PRINT NAME OF INSPECTOR S NATURE OF INSPECTOR DATE File form with original signature to the Fire Inspectors Office at the above address, Do not FAX. ANY FALSE STATEMENT MADE HEREIN IS PUNISHABLE AS A MISDEMEANOR Office Use Only: Comments: Date Received ~ - I ~ - 06 36-FireAlarmlnspFm 6/30/04 @) Flre'L1Te" ALarms www.flrellte.com July 15. 2004 OF -50673 . F -850 302 Series Rate-Anticipation Heat Detectors Section: Conventional Initiating Devices GENERAL The Thermotech 302 Series rate-anticipation heat detec- tors operate within a controlled range of two to three de- grees of their set points, regardless of the speed or rate of temperature rise. These detectors are available in either 1350F or 1940F ratings. The 302 Series are normally-open devices designed es- pecially for fire detection and alarm systems. @ <@> I California " State Fire VL FM ~~ Marshal APPROVED 7270-0021 :001 LISTED J.1.5H3M3.AY (All) 5539 E35018A FEATURES Immediate response. The 302 Series activate whenever ambient air temperature reaches a detector's setting, eliminating the thermal time lag inherent in conventional heat detectors. Eliminates false alarms. The 302 Series do not respond to momentary temperature fluctuations below the selected temperature. Universal application. The 302 Series can be used in all areas for any type of occupancy. Self-restoring. Hermetically sealed, shock resistant, corrosion resistant, and tamper-proof. PRINCIPLES OF OPERATION The 302 Series rate-anticipation heat detectors re- spond and activate the fire alarm immediately when- ever the ambient temperature reaches the preset temperature setting. Under rapid heat rise condi- tions, the rate-anticipation feature enables the de- tector to respond one to three degrees ahead of the setting. At the same time, however, it does not respond to momentary temperature fluctuations be- low the selected protection level, thus eliminating false alarms. When temperature drops back down below the protection level, the detector automati- cally resets itself. DIMENSIONS (Model 302) Total overall length: 4-1i8" Base diameter: 2" ELECTRICAL RATINGS Voltage 6-125 VAC 6-25 VDC 125 VDC Current 5 amps 1 amp 0.5 amp APPLICATION INFORMATION 302 Series detectors have a smooth.ceiling UL rating of 50' x 50' (15.24 x 15.24 meters) and are the only type of heat detectors having such a rating on both fixed tempera- ture and rate anticipation. The 302-H is designed for hori- zontal mounting and UL rated for 40' x 40' (12.19 x 12.19 meters). This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate, We cannot cover all specitic applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact FlreoLlte Alarms, One Fire-Lite Place, Northford, Connecticut 06472. Phone: {800} 627- 3473, Toll Free FAX: (877) 699-4105, FAX Back:(888} 388-3299 WEB: WN'W,firelite.com ISO 9001 CERTIFIED ENGIN/IIING I MANUIAClIIING DF-50673 o07f15/04 _ Page 1 of 2 PRODUCT LINE INFORMATION Thermotech Model 302 Series Rate-Anticipation Heat Detectors MODEL NUMBER DESCRIPTION 302-135 1350F Interior Vertical Mounting, FM and UL. REFER TO Note 1 below. 302-194 1940F Interior Vertical Mounting, FM and UL. 302-AW-135 302-AW-194 1350F AI~Weather Vertical Mounting, FM and UL. 1940F AI~Weather Vertical Mounting, FM and UL. 302-ET-135 302-ET-194 1350F All-Weather Vertical Mounting, FM and UL. 1940F All-Weather Vertical Mounting, FM and UL. 302-H-135 302-H-194 1350F Interior Horizontal Mounting, FM and UL. 1940F Interior Horizontal Mounting, FM and UL. 302-EPM-135 302-EPM-194 1350F ExplosiorrProof Mounting, UL.. 1940F ExplosiorrProof Mounting, UL. HIGH EXPANSION SENSING SHELL 0.040 ANODIZED ALUMINUM Decorative white plastic adaptor plate for mounting 302 and 302-AW to 4" outlet box. Note 1: For interior mounting in any atmosphere that is compatible with terminal screw type connections. UL rating 50' x 50' (15.24 x 15.24 meters). Note 2: Humitically sealed for moisture-proof or dust- proof installations. Requires no special backbox when the all-weather leads are properly spliced to 'THW' or equivalent type wire. Note 3: Humitically sealed for moisture-proof or dust- proof installations. Requires no special backbox. Has plastic hexagonal wrench grip bushing with 1/2" (1.27 em) conduit threads for attachment to threaded hub cover, or any outlet box. Note 4: Same as model 302 except designed for hori- zontal mounting. UL rating 40' x 40' (12.19 x 12.19 meters). Note 5: Explosion-proof for installation in hazardous lo- cations. Has hexagonal wrench grip bushing with 1/2" (1.27 em) conduit threads for attach- ment to threaded hub cover of Series JL fixture fitting as manufactured by Killark Electric Co., or equal. AP-P FINE SILVER CONTACT POINTS EXPANSION STRUTS HEAT ANTICIPATION CONTROL SLEEVE SETTING SCREW DEVCON HERMETIC SEAL Cut-Away View, ACTUAL SIZE Page 2 of 2 - DF-50673' 07/15/04 Fire Alarm Systems I FMM-462 Senes POPIT Addressable Manual Stations @ BOSCH Invented for life FMM-462 Series POPIT Addressable Manual Stations FIRE 0 FIRE FIRE) FIRE ~ TT BOSCH The FMM-462 Series Addressable Manual Stations allow people evacuating a building to initiate an alarm and alert others still inside. This UL-Iisted initiating device is compatible with the Bosch G Series Control Panels and the D9124 Fire Alarm Control Panel (FACP). The POPIT module is addressed using on-board slide switches. It is then connected to a D9124 data expansion loop. The POPIT is polled by the control panel and sends reports on any opens, shorts, or ground faults on the manual station's wiring. The addressable feature allows the agencies responding to alarm or trouble conditions to go to the point that initiated the alarm or trouble report. These low-profile manual stations are die cast with rounded edges to fit most design applications. All metallic components are painted or plated to inhibit corrosion. The FMM-462 Series Manual Stations conform with the Americans with Disabilities Act (ADA) standards. Functions Addressable Operation The POPIT connects to a two-wire data expansion circuit from the control panel. Device address is set through slide switches on the POPIT Module, allowing . Single-gang mounting . Latching alarm lever and key-locked reset . Rugged die-cast housing with 14 gauge (1.9 mm) plated steel back and corrosion-resistant construction ... Optional scored acrylic breakrod programmable device identification by the control panel. Certifications and Approvais listings and Approvals: Complies with: UL UNIU, Boxes, Non-Coded (UL38) CSFM, 7150-1615,122 ADA 4.28.3 NFPA 72 Installation/Configuration Notes Compatibility Information The FMM-462 Series Addressable Manual Stations are compatible with the following products, Category Control Panels: Product ID D7212G D7412G D9412G D9124 D9127U Product Description Control panel Control panel Control panel Addressable FACP POPIT module Modules Mounting Considerations The FMM-462 manual stations are for indoor use only. www.boschsecurity.com 2 I FMM-462 Series POPIT Addressable Manual Stations The FMM-462 or FMM-462-D and the wiring from the control panel data expansion loop fit into a single-gang back box for flush mounting. Use the larger FMM-100BB- R Back Box for surface mounting and to provide additional room for system wiring and the module. Technical Specifications Environmental Considerations Temperature (operating): Mechanical Properties + 14"F to + 120"F (-lOOe to +490C) Parts Included Material: Sib (2.3 kg) 1 see (approximately) 4.75 in. x 3.2 in. x 0.875 in. (12.1cmx8.1cmx2.2 em) Painted die-cast metal, plated steel back and painted steel front Power Requirements Activation Force: Quant. 1 1 1 1 1 Component Manual station 09127U POPIT module FMM.I00GR scored acrylic breakrod 0102 Key (1358) literature pack Alarm Response Time: Dimensions (HxWxD): Current (alarm): Current (normal): Voltage (operating): 0.8mA 0.5mA 7VDCto 15 VDCsupplied by the control panel Ordering Information FMM-462 Single-Action Manual Station FMM-462-D Double Action Manual Station Hardware Accessories D102 Replacement Key FMM-100BB-R Surface-mount Back Box (red) FMM.100GR Scored Acrylic Breakrods FMM-462 FMM-462.0 0102 FMM-l0088-R FMM-l00GR .t.m.rlcu: 80sch S&Curity Systems 130PerlntonParkway Fairport,NewYork,14450,USA Pnone:+15852234060 1'",,:+18002890096 securily.salu@us.bosch.com www.boschsacurily.us Europel, Mlddl.eut, AfrIea: Boscn Security Systems B.V. P.O. Box 80002 5600 JB Eilldhoven.The Netherlands Phone: +31 (0)402183955 FaJC:+31 (0)402786668 emea.se<::uritysystemS4llbosch.com www.boschsecurity.com ....Ia-Paclfle: BoschSecuritySystamsPteltd 38CJalanPemlmpln Singapore 577180 Phone: +6563193450 1'"",+6563193499 apr.securltysystems@bosch.com www.boschsecl.lrity.com R.pru.ntlldby CI Bosch Security Systems 20061 Data sl,lbject to changewithol,lt notl ce F1930529547ICur:en.US,V3,16Jan200610ocNo.F01U005394en-D3 AUDIBLE/VISIBLE NOTIFICATION SPECT~rt Selectable Output Strobe and Horn/Strobes Models Available Strobes Red S1224MC S1224MCP S1224MCK S1224MCSP White S1224MCW S1224MCPW Horn/Strobes Red P1224MC P1224MCP P1224MCK P1224MCSP White P1224MCW P1224MCPW Horns Red H12/24 H12/24K White H12/24W Product Overview ~~ SYSTEM '--~ SENSOR' Operates on either :L2V or 24V Widest range of candela options: J.2V: J.5 and J.5/75 candela 24V: J.5, J.5/75, 30, 75, J.J.O candela Easy candela selection Lower current draw Easy DIP switch selection for horn options Easy mounting with QuickClick™ Synchronizable with MOL Sync-Circuit™ module Meets ULJ.971., NFPA 72, and ADA signaling requirements All strobe and horn/strobe models incorporate a new patent-pending voltage booster design that has a more consistent flash bulb voltage over the range of candela selections. The benefit to the customer is a high quality strobe device. @ USTED .~:;: ~ <8> 7125-1209:222 ..........u 7135-1209:223 3014150 @ CS549V602NK1T954 CS549V702NK13151 MEA approved 12:2"()2-E 126-02-E SpectrAlert@ Selectable Output Horns, Strobes, and Horn/Strobes offer enhanced fea- tures that include the widest range of candela options available and the capability to recognize and self-adjust for either 12 or 24 volt operation. With an overall feature set that combines performance, installation ease, flexibility, and a consistent, aesthetically pleasing appearance. the SpectrAlert Selectable Output devices provide both the innovation and efficiency synonymous with the SpectrAlert name. Performance. SpectrAlert selectable output wall-mount horns, strobes, and horn/strobes offer key performance features long associated with the SpectrAlert name. The select- able candela strobes and horn/strobes offer average current draws that are not only lower than conventional fixed-candela SpectrAlert products, but al~o lower than similar selectable candela products. By consuming less current, the ability to connect even more devices per loop is possible, resulting in a lower installed cost. Installation. SpectrAlert selectable output horns, strobes, and horn/strobes offer the same installation-friendly features synonymous with the SpectrAlert name, such as the option of 2- and 4-wire operation; the ability to use standard size backboxes with no encroachment into the box; and universal mounting incorporating the labor-saving QuickClick.... feature. Such labor-savings features make wire connections simple and fast, further reducing installed cost. Flexibility. SpectrAlert selectable output strobes and horn/strobes offer the broadest range of candela options. In addition, the selectable output strobes and horn/strobes can operate on either 12V or 24V, with no setting required; the device recognizes and self-adjusts to the correct current automatically. Temporal 3 or Continuous tone options continue to be available, in either an Electromechanical or 3kHz pattern. Aesthetics. SpectrAlert selectable output horns, strobes, and horn/strobes incorporate the same stylish, low profile design of the conventional SpectrAlert products, for a con- sistent and aesthetically pleasing appearance across the entire product line. Engineering Specifications General SpectrAlert horns, strobes and horn/strobes shall be capable of mounting to a standard 4" x 4" x 11/2" back box or a single gang 2" x 4" x F!~" back box using the universal mounting plate included with each SpectrAlert product. Also, SpectrAlert prod- ucts, when used in conjunction with the accessory Sync-Circuit Module, shall be powered from a non-coded power supply and shall operate on 12 or 24 volts. 12 volt rated devices shall have an operating voltage range of 9-17.5 volts. 24-volt rated devices shall have an operating voltage range or 17-33 volts. SpectrAlert products shall have an operating temperature of 3ZO to 1200F and operate from a regulated DC or full wave rectified, unfiltered power supply. Strobe Strobe shall be a System Sensor SpectrAlert Model_ listed to UL 1971 and be approved for fire protective service. The strobe shall be wired as a primary signaling notification appliance and comply with the Americans with Disabilities Act require- ments for visible signaling appliances, flashing at 1Hz over the strobe's entire operating voltage range. The strobe light shall con- sist of a xenon flash tube and associated lenslreflector system. Horn/Strobe Combination Horn/Strobe shall be a System Sensor SpectrAlert Model _ listed to UL 1971 and UL 464 and shall be approved for Speclflcatlons Walk Test SpectrAlert horn/strobe and horn only work on "walk tests" with time dura- tions of 4 seconds or greater Input Terminals 12 to 18 AWG Dimensions Strobe and horn/strobe with universal plate 5" x 55/8" X 215/16" Strobe and horn/strobe with small footprint plate 33/8" x 55/8" X 25/16" Horn with universal mounting plate 5" x 55/8" X 15/16" Horn without mounting plate 215/16" x 55/16" X 15/16" Weight, horn only 7,20z, fire protective service. Horn/strobe shall be wired as a primary signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two tone options, two audibility options (at 24 volts) and the option to switch between a temporal 3 pattern and a non-temporal continuous pattern. Strobes shall be powered independently of the sounder with the removal of factory installed jumper wires. The horn on horn! strobe models shall operate on a coded or non-coded power sup- ply (the strobe must be powered continuously). Synchronization Module Module shall be a System Sensor Sync-Circuit _ listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1Hz and horns at temporal 3. Also, the module shall silence the horns on horn! strobe models, while operating the strobes, over a single pair of wires. The module shall be capable of mounting to a 411/16" x 411/16" x 2lls" back box and shall control two Style Y (class B) or one Style Z (class A) circuit. Module shall be capable of multiple zone synchronization by daisy chaining multiple modules together and re-synchronizing each other along the chain. The module shall not operate on a coded power supply. Weight, strobe and horn/strobe 8,8 oz. Operating voltage range'" 12V: 8-17,5V:24V: 16-33V Operating voltage range'" (with Sync-Circuit module, MOL) 12V:9-17,5V; 24V: 17-33V *Note for Strobes: Do not exceed; 1) 16-33 or 8-17.5 voltage range limit; 2) maximum number of 70 strobe lights when connecting the MOL Sync module with a maximum line impedance of 4 ohms per loop and; 3) maximum line impedance as required by the fire alarm control manufacturer Mounting 4" x 4" X 11/2" or 2" x 4" X 17/8" standard boxes Indoor Operating Temperature 320F to 1200F (OOC to 490C) Max irnum fwmidity 95% as tested per UL464 Operating Temperature Weatherproof (horn and horn/strobes) 320F to 1500F (OOC to 660C) (outdoor strobe only) -40oF to 1580F (-40oC to 700C) ULC Canadian Models -40oC to 660C u.s. Patent Numhers 5,593,569 5,914,665 6,049,446 Voltages 12 or 24VDC and FWR unfiltered SpectrAlert Current Draw FWR Operating DC Operating Current- FWR Operating DC Operating Current-Strobe Strobe Current-Horn Current-Horn Candela mA RMS mA RMS) mA RMS mA RMS Series Settin 12V 24V 12V 24V 12V 24V 12V 24V S1224MC 15 112 64 127 59 Strobes 15/75 135 74 127 69 30 93 90 75 158 160 110 208 209 P1224MC 15 112 64 127 59 45.7 57.5 Horn/Strobes 15/75 135 74 127 69 45.7 57.5 30 93 90 57.5 75 158 160 57.5 110 208 209 57.5 H12/24 Horns 45.7 57.5 44.4 SpectrAlert Mounting and Operation Candela Selections Selectable Horn Tones For strobe candela selection, adjust slide switch located on the rear of the product while watching the viewing window on the side of the reflector. A0133-OO Permissible Candela Settings Temporal Low Volume Electromechanical 3000 Hz Interrupted High Volume Electromechanical 3000 Hz Interrupted NOD-Temporal Low Volume Electromechanical 3000 Hz Interrupted High Volume Electromechanical 3000 Hz Interrupted Candela Operating Voltage Setting 12V 24V 15 OK OK 15/75 OK OK 30 OK 75 OK 110 OK DIP Switch Operation OFF Factory Default DIP Switch ON D Low DI!I High II!!!!!II:=J Non- Temporal II!!!!!II:=J 3000Hz Base (rear) Temporal A0110-OO Electromech. Typical weatherproof mounting with universal plate rWBB o A0120-00 Conduit Entrance SpectrAlert Ordering Information Model Description P 1224M C Selectable Output Horn/Strobe, 12/24 volt, red P1224MCW Selectable Output Horn/Strobe. 12/24 volt, white P1224MCP Selectable Output Horn/Strobe, 12/24 volt, red. plain housing P1224MCPW Selectable Output Horn/Strobe, 12/24 volt. white, plain housing P1224MCK Selectable Output Horn/Strobe, 12/24 volt, red, weatherproof P1224MCSP Selectable Output Horn/Strobe, 12/24 volt, red, "FUEGO~ housing S1224MC Selectable Output Strobe. 12/24 volt, red S1224MCW Selectable Output Strobe, 12/24 volt. white S1224MCP Selectable Output Strobe, 12/24 volt, red. plain housing S1224MCPW Selectable Output Strobe. 12/24 volt, white. plain housing S1224MCK Selectable Output Strobe, 12/24 vott, red, weatherproof S1224MCSP Selectable Output Strobe, 12/24 volt, red, ~FUEGon housing Model Description H 12/ 24 Horn, 12/24 volt, red H12/24W Horn, 12/24 volt, white H12/24K Horn, 12/24 volt, red, weatherproof Accessories MDL Sync-Circuit Module, red MDLW Sync-Circuit Module, white MDLA Sync-Circuit Module, red, Canadian model MDLWA Sync-Circuit Module, white, Canadian model 5-MP Small Footprint Mounting Plate, red, for single- gang back box 5-MPW Small Footprint Mounting Plate, white, for single- gang back box 88S Surface Mount Back Box Skirt, red 88SW Surface Mount Back Box Skirt, white D-MP Universal Mounting Plate (replacement), red D-MPW Universal Mounting Plate (replacement), white W88 Weatherproof Back Box Notes Agency Listings - Indoor models: UL. ULe, FM, CSFM. MEA. Weatherproof models: UL, CSFM (strobe only), MEA, ULe. All of these SpectrAlert products are designed for wall mount only. All weatherproof models !D.llli. use weatherproof back box model WBB. Installation of less than 75 candela strobes may be permissible under the equivalent facilitation clause of the ADAAG (Sec. 2.2). However, it is the responsibility of the person or entity designing the fiee alarm system to determine the acceptability of less than 75 candela strobes. All 15/75 candela strobes or horn! strobes are recommended for 20' x 20' rooms or less. System Sensor Sales and Service System Sensor Headquarters 3825 Ohio Avenue St. Charles, IL 60174 Ph: 800/SENSOR2 Fx: 630/377-6495 Documents-on-Demand 800/736-7672 x3 www.systemsensor.com System Sensor Canada Ph: 905.812.0767 Fx: 905.812.0771 System Sensor Europe Ph: 44.1403.891920 Fx; 44.1403.891921 System Sensor In China Ph: 86.29.524.6253 Fx: 86.29.524.6259 System Sensor In Singapore Ph: 65.6273.2230 Fx: 65.6273.2610 System Sensor - Far East Ph: 85.22.191.9003 Fx: 85.22.736.6580 System Sensor - Australia Ph: 613.54.281.142 Fx: 613.54.281.172 System Sensor - India Ph: 91.124.237.1770 x.2700 Fx: 91.124.237.3118 System Sensor - Russia Ph: 70.95.937.7982 Fx: 70.95.937.7983 C 2004 System Sensor. The company reserves the right to change product specifications .....ithout notice. A05-0325-003.S/040#1200 Fire Alarm Systems I D7024 Addressable Fire Alarm Control Panels 07024 Addressable Fire Alarm Control Panels (@! Fire Systems The D7024 Addressable Fire Alarm Control Panels (FACPs) can be used in commercial and public building applications such as schools, universities. manufacturing plants, and health care facilities. They are listed by UL for central station,local, auxiliary, and remote station systems. Adding the D7039 Multiplex Expansion Modules to the D7024 Conventional FACPs with version 2.02 or higher firmware makes the FACPs addressable with up to 255 addressable points. The FACPs support both two-wire and four-wire detectors. Each FACP has a built-in digital fire alarm communicator transmitter (DACT) and four on-board detection zones that can be expanded to eight zones. Each wne can support up to 20 two-wire detectors, or any number of four-wire detectors (depending on available power). Functions Notification Appliance Circuits (NACs) Two notification appliance circuits (NAC) provide up to 4 A of 24 VDC power to operate horns, strobes, bells, and other notification appliances. Each NAC can be programmed to provide Temporal Code 3, steady, pulsed, and synchronized output for WheelockTM and Gentex™ notification appliances. Up to 255 addressable points and 58 programmable relay outputs Four detector zones (expandable to eight); up to 20 two-wire smoke detectors per zone Built-;n DACT Two NACs on board with internal 24 VDC, 4 A NAC power supply Programmable through front panel interlace, remote D7033 Fire System Keypad, or Remote Programming Software (RPS) User Interface A viewing port in the keyed control panel enclosure door leaves the system status light-emitting diodes (LEDs) and liquid-crystal display (LCD) visible while maintaining system keypad security. Unlocking the enclosure door provides access to the system keys for silencing alarm and trouble conditions, zone bypassing, detector resetting, testing, other fire functions, and programming. These functions are also available on all D7033 LCD Keypads connected to the system. All D7036 LCD Annunciators provide custom text annunciation on a 32-character, backlit, two-line LCD display. All system keypads and annunciators have built-in sounders. Back-light intensity and sounder volume are programmable. Personal Identification Numbers (PINs) There are 100 PINs available for accessing system control. Assign each number an authority level to limit the system control functions that can be accessed. History Buffer The system stores events in a 499-event history buffer. Central Station Reporting The D7024 FACP sends reports to two telephone numbers with full single, double, and backup reporting and communicate in BFSK, SIA, Contact!D, Modem llIa 2, and 4/2 and 3/1 Tone Bursts. BOSCH " 2 I D7024 Addressable Fire Alarm Control Panels CleanMe@ Compatible The D7024 FACP recognizes the CleanMe signal from Bosch's F220 Smoke Detectors. If a detector's smoke chamber is dirty, the detector sends a signal on the loop (two-wire or addressable) and the control panel annunciates that there is a dirty detector on the loop. Accessories The D7024 enclosure has space for additional accessory modules and two D1218 batteries or two D126 batteries. Certifications and Approvals Listings and Approvals: UL UOJZ: Control Units, System (UL864) CSFM 7165.1615, 147 Factory Mutual Research NYC/MEA (12-92-E, Vol. 7 and Vol. 14) Complies with: Hong Kong Fire Services Department Installation/Configuration Notes Compatible Products The following products are compatible with the D7024 FACP: Category Product 10 Product Description Batteries and 0126 12 V, 7 Ah battery Power Supply 0184A Local energy kit Devices 01218 12 V, 18 Ah battery 07038 Remote NAC power supply Detectors and 07050 Addressable photoelectric smoke Detector Bases defector 07050TH Addressable photoelectric smoke and heat detector 07050-86 Addressable detector base Keypads and Annunciators For others, refer to 07022-07024 Compatibility List Technogram (PIN: 34445) 07030X Eight-point LEO annunciator (eight red) 07030X-S2 Eight-point LEO annunciator (two yellow, six red) 07030X-SB Eight-point LED annunciator (eight yellow) 07032 Eight-point LEO annunciator expander (eight red) 07033 LCO fire system keypad 07036 LCO annunciator Modules NAC Oevices Pull Stations 01328 0185 0275 07014 07015 07031 07034 07035 070358 07039 07039R 07042 070428 07044 07044M 07048 070488 Smoke detector reversing relay module Reversing polarity module EOL power supervision module Zone converter module Class B to Class A NAC converter Silence reset module Four-point expander Octal relay module Octal relay module in box Multiplex expansion module Multiplex expansion module retrofit kit Multiplex eight-input remote module Multiplex eight-input remote module in box Multiplex single-input module Mini multiplex single-input module Multiplex octal driver Multiplex octal driver in box 07052 Multiplex dual-input module 07053 Multiplex input-output module Refer to 07024 NAC Compatibility List Technogram (PIN: 40374) 07045 Multiplex pull station Technical Specifications Temperature (operating): liIl COn$ld.....tIon.. . . +320F to +120oF (DOC to +490C) Color: Dimensions (HxWxO): _ailleal PI_riles :" Material: Red 20.8 in. x 15 in. x 4.3 in. (52.8 cm x 38.1 cm x 10.9 cm) Cold-rolled steel Base: 18 gauge (1.2 mm) Cover: 19 gauge (1.1 mm) 0iI1put& .., NAG: On-board Relays: Off-board Relays: 24 VOC nominal, 4 A maximum Two Form C contacts rated at 5 A, 28 VDC Up to two 07035 Octal Relay Modules each providing eight Form C relay outputs; contacts rated at 5 A, 28 VOC; up to 20 07053 Multiplex Input-Output Modules per bus for a total of 40 POwer Requioemenlll . ": ' Current (alarm): Current (standby): Power (primary) 380 mA 200 mA 120 VAC, 1.5 A maximum, 60 Hz sensor citCUftS', { , ,,os " ' Current: une resistance: Voltage: 44 mA maximum per loop 1500 24 VDC nominal 1'I1ldemarkS ' '; , j , , CleanMe@isatrademarkofGElnterlogix. WheelockTlol is a trademark of Wheelock, Inc. GentexTlol is a trademark of Gentex Corporation. D7024 Addressable Fire Alarm Control Panels I 3 Ordering Information 07024 Four-zone FACP* 07024LC Four-zone FACP* without Enclosure Software Options 07024-CO Reference CD D7024 D7024LG D7024-GD CONVENTIONAL DETECTION Model BEAM1224(S) Single-ended Reflected Type Beam Smoke Detector Models Available BEAM1224 BEAM1224S 4 wire conventional beam smoke detector with 8'" reflector 4 wire conventional beam smoke detector with 8" reflector and integral sensitivity test Accessories BEAMLRK BEAMMMK BEAMSMK RTS451 RTS451KEY BEAMHK BEAMHKR ~~ SYSTEM C~ SENSOR Long range accessory kit (3) additional reflectors (Required for applications in excess of 230 ft. [70m]) Multi-mount kit (Provides ceiling or wall mount capability with increased angular adjustment for either the beam or the reftector. When Installed with the transmitter/receiver unit, BEAMSMK must be used as well) Surface mount kit Remote test station used to initiate the NFPA sensitivity test function Remote test station with key lock Heater kit for transmitter/receiver unit (See electrical requirements on back) Heater kit for reflector (See electrical requirements on back) Product Overview 16 to 328 foot protection range Single-ended, reflective design User friendly alignment procedure 6 user selectable sensitivity levels Optional integral NFPA 72 sensitivity test feature Removable plug-in terminal blocks Digital display for easy alignment BuiltMin automatic gain control compensates for signal deterioration from dust bulld.up Remote test station optional Paintable cover Easiest alignment in the industry ~~I ~~ ~~ 5911 3017BBB 7260-1209:22B 54-04-E 2165 Iv" L ./.....l1 ~ r/'t>J"'J eC-I '0 System Sensor Model BEAM1224 is a 4-wire conventional projected beam smoke detector. It is uniquely suited for protecting open areas with high ceilings where other methods of smoke detection are difficult to install and maintain. It is to be used with UL Listed compatible control panels only. Installation of the single-ended reflective design is much easier than the dual-ended projected beam detectors. Alignment is quickly accomplished via an optical sight and a 2-digit signal strength meter incor- porated into the product. Listed for operation from _220P to 1310F, BEAM1224 can be used in open area applications to provide early warning in environments where temperature extremes exceed the capability of other types of smoke detection. BEAM1224 consists of a transmitter/receiver unit and a reflector. When smoke enters the area between the unit and the reflector it causes a reduction in the signal and, when the smoke level reaches the predetermined threshold, an alarm is activated. BEAM1224 has four standard sensitivity selections along with two Acclimate set- tings. When either of the two Acclimate settings are selected the detector will auto- matically adjust its sensitivity using advanced software algorithms to select the opti- mum sensitivity for the specific environment. BEAM1224S is equipped with an integral sensitivity test feature that consists of a test filter attached to a servo motor inside the detector optics. Using the remote test station RTS451, the motor is activated and moves the filter in the pathway of the light beam, thereby testing detector sensitivity. This integral sensitivity test feature allows the user to quickly and easily meet the annual maintenance and test require- ments of NFPA 72. . Operational Specifications Protection Range 16 ft. to 328 ft. (5m to 100m) Adjustment Angle +/- 10 Degrees horizontal & vertical (The optics move independent of the unit) Sensitivity Levels Level 1 - 25% Level 2 - 30% Level 3 - 40% Level 4 - 50% Acclimate Levell - 30-50% Acclimate Level 2 - 40-50% Fault Condition (Trouble) 96% or more obscuration blockage J n alignment mode Improper initial alignment Self-compensation limit reached Alignment Aid Optical gunsight Integral signal strength indication 2-digit display Alarm Indicator Local red LED and remote alarm Trouble Indicatm Local yellow LED and remote trouble Normal Indicator Local ftashing green LED Test/Reset Features Integral Sensitivity Test Filter (BEAMl224S only) Sensitivity fi Iter (Incremental scale on reflector) Local alarm test switch Local alarm reset switch Remote test and reset switch (Compatible with RTS451 and RTS451KEY test station) Smoke Detector Spacing On smooth ceilings, 3Q....60 feet between projected beams and not more than one-half that spacing between a projected beam and a sidewall. Other spacing may be used depending on ceiling height, System Sensor Sales and Service airflow characteristics, and response requirements. See NFPA 72. Environmental Specifications Temperature -22"F to 131"F (-30"C to 55"C) Htunidity 10-93% RH Noncondensing Electrical Specifications Voltage 10.2 to 32 VDC (BEAM1224) 15 to 32 VDC (BEAM1224S) BEAM1224S should not be used with 12V power sources AVG. StandlJY Current (24VDC) 17mA Max AVG. Current During Testing 500mA Max AVG. Alarm Current (24VDC) 38.5mA Max AVG. Fault Current (24VDC) 8.5mA Max AVG. Alignment Mode Current (24VDC) 28mA Max Mechanical Specifications Detector Dimensions 10"H x 7.5"W x 3.3"D (254mmH x 191mmW x 84mmD) Reflector Dimensions (16' to 230') 7.9" x 9.1" (200 x 230mm) Reflector Dimensions for (beyond 230') 15.7" x 18.1" (400 x 460mm) Electrical Specifications (BEAMHKR) Voltage 15 to 32V Current 450mA Max at 32V (per reftector) Power Consumption (Per reflector) 7.7W @ 24V; 15W @ 32V Electrical Specifications (BEAMHK) Voltage 15 to 32V Current 92mA at 32V Power Consumption 1.6W @ 24V; 3W @ 32V Ol'TICALGUNSlGfIT ALIGNMENT SIGNAL STRENGTH METER HORIZONTAL OPTICS ALIGNMENT KNOB ALIGNMENT SENSITiVITY TEST VERTICAL OPTICS ALIGNMENT KNOB RESET .. .. n~l ~~ ~ H!! lip ;il I ! 1 ! C0271-01 Activated Test Feature (BEAM12245 only) SERVOMOTOR = (<) [Q] ~6 (<) : QQ rQ 6 G System Sensor Headquarters 3825 Ohio Avenue St. Charles, IL 60174 Ph: 800/SENSOR2 Fx: 630/377-6495 www.systemsensor.com System Sensor Canada Ph: 905.812.0767 Fx: 905.812.0771 System Sensor Europe Ph: 44.1403.891920 Fx: 44.1403.891921 System Sensor In China Ph: 86.29.8832.0119 Fx: 86.29.8832.5119 System Sensor In Singapore Ph: 65.6273.2230 Fx: 65.6273.2610 ~ 2005 System Sensor. The company reserves the right to change product specifications without notice. System Sensor - Far East Ph: 85.22.191.9003 Fx: 85.22.736.6580 System Sensor - Australia Ph: 613.54.281.142 Fx: 613.54.281.172 System Sensor - India Ph: 91.124.237.1770 x.2700 Fx: 91.124.237.3118 System Sensor - Russia Ph: 70.95.937.7982 Fx: 70.95.937.7983 A05~36~002.2/05.#1397