Loading...
HomeMy WebLinkAbout32209-Z FORM NO. 4 TOWN OF SOUTHOLD BUILDING DEPARTMENT Office of the Building Inspector Town Hall Southold, N.Y. CERTIFICATE OF OCCUPANCY No: Z-32873 Date: 02/07/08 THIS CERTIFIES that the building ADDITIONS/ALTERATIONS Location of Property: 575 (HOUSE NO.) County Tax Map No. 473889 Section 116 BEACHWOOD RD (STREET) Block L- CUTCHOGUE (HAMLET) Lot 21 Subdivision Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated JULY 13, 2006 pursuant to which Building Permit No. 32209-Z dated JULY 13, 2006 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is ADDITIONS & ALTERATIONS TO AN EXISTING SINGLE FAMILY DWELLING AS APPLIED FOR & AS PER CONDITIONS OF ZBA #5711 DATED 11/17/05. The certificate is issued to MARY RAYNOR (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPAR~ OF HEALTH APPROVAL N/A ELECTRICAL CERTIFICATE NO. 3028943 09/21/07 PLUMBERS CERTIFICATION DATED 12/31/07 GEORGE BERRY, JR. ~ri~ Rev. 1/81 ~ . Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 I "- ";, (" -, 6'<'2' / <?~ 'j APPLICATION FOR CERTIFICATE OF OCCUPANCY " This application must be filled in by typewriter or ink and submitted to the Building Department with the following: " '-":',1 A. For new building or new use: " / I. Final survey of property with accurate location of all buildings, property lines, streets, and unusual natural Dl'V' topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/1 0 of I % lead. 5. Commercial building, industrial building, multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings (prior to April 9,1957) non-conforming uses, or buildings and "pre-existing" land uses: I. Accurate survey of property showing all property lines, streets, building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied, the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees New Construction: 1. Certificate of Occupancy - New dwelling $25.00, Additions to dwelling $25.00, Alterations to dwelling $25.00, Swimming pool $25.00, Accessory building $25.00, Additions to accessory building $25.00, Businesses $50.00. 2. Certificate of Occupancy on Pre-existing Building - $100.00 3. Copy of Certificate of Occupancy - $.25 4. Updated Certificate of Occupancy - $50.00 5. Temporary Certificate of Occupancy - Residential $15.00, Commercial $15.00 f Date. I}J 1:1._ O? / (check one) Cu\(l(,~,E' amlet Old or Pre-existing Building: Bea <: l. '-.:- ~0'0. Qc\ ~ Stre;\ k \,,~':\ t\~ Block z;-") ') House No. Owner or Owners of Property: ~ \ \C;, Location of Property: Suffolk County Tax Map No 1000, Section 1;'--, \ Lot Subdivision Permit No. 3~d.09'c... Date ofpermit. Health Dept. Approval: Filed Map. Applicant: Lot: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: ~ (check one) Fee Submitted: $ /1 "J /,}IA~ )(( (~W'--L App . ant Signature W-c 1)7 5 ( co-Z3:J2)?3 FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 32209 Z Date JULY 13, 2006 permission is hereby granted to: MARY RAYNOR 575 BEACHWOOD RD CUTCHOGUE,NY 11935 for : ADDITIONS AND ALTERATIONS TO AN EXISTING SINGLE FAMILY DWELLING AS APPLIED FOR TO ALL CONDITIONS OF DEC, TRUSTEES & ZBA AS REQUIRED wi FLOOD PERMI at premises located at 575 BEACHWOOD RD CUTCHOGUE County Tax Map No. 473889 Section 116 Block 0004 Lot No. 021 pursuant to application dated JULY 13, 2006 and approved by the Fee $ 467.80 '- Building Inspector to expire on JANUARY ORIGINAL Rev. 5/8/02 @J~ .@J I BY THIS CERTIFICATE OF COMPLIANCE THE I ~ NEW YORK BOARD OF FIRE UNDERWRITERS ~ ~ BUREAU OF ELECTRICITY ~ ~ 40 FULTON STREET - NEW YORK, NY 1 0038 ~ ~ CERTIFIES THAT ~ ~ ~ ~ Upon the application of upon premises owned by ~ ~ ~ ~ ROSLAK ELECTRIC HENRY RAYNOR ~ ~ PO BOX 164 575 BEACHWOOD ROAD ~ I CUTCHOGUE, NY 11935-2453, MATTITUCK, NY 11952 I ~ Located at 575 BEACHWOOD ROAD MATTITUCK, NY 11952 ~ ~ ~ ~ Application Number: 3028943 Certificate Number: 3028943 ~ ~ Section: Block: Lot: Building Permit: BDC: n511 ~ ~ ~ ~ Described as a occupancy, wherein the premises electrical system consisting of ~ ~ electrical devices and wiring, described below, located inion the premises at: ~ ~ First Floor, Second Floor, Detached Garage, Outside, ~ ~ A visual inspection of the premises electrical system, limited to electrical devices and wiring to the extent detailed ~ ~ herein, was conducted in accordance with the requirements of the applicable code andlor standard ~ ~ promulgated by the State of New York, Department of State Code Enforcement and Administration, or other ~ ~ authority having jurisdiction, and found to be in compliance therewith on the 21st Day of September, 2007. ~ ~ Name OTY Rate Rating Circuit ~ ~ ~ Receptacle 2 0 20a Laundry ~ ~ GFCI Circuit Breaker I 0 20a ~ ~ Receptacle II 0 GFCI ~ @! Service ii!l ~ 1 Phase 3W Service Rating 200 Amperes ~ ~ Service Disconnect: 1 200 cb ~ ~ ~eters: I ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ seal ~ ~ ~ ~ 2 of 2 ~ I ~ ~ This certificate may not be altered in any way and is validated only by the presence of a raised seal at the location indicated. I L!I.L!I 1/ 0~ - '-I - 2) IID.IID I BY THIS CERTIFICATE OF COMPLIANCE THE I ~ NEW YORK BOARD OF FIRE UNDERWRITERS ~ ~ BUREAU OF ELECTRICITY ~ ~ 40 FULTON STREET - NEW YORK, NY 1 0038 ~ ~ CERTIFIES THAT ~ ~ ~ ~ Upon the application of upon premises owned by ~ ~ ~ ~ ROSLAK ELECTRIC HENRY RAYNOR ~ ~ PO BOX 164 575 BEACHWOOD ROAD ~ @l CUTCHOGUE, NY 11935-2453, MATTITUCK NY 11952 @l ~ '~ ~ Located at 575 BEACHWOOD ROAD MATTITUCK, NY 11952 ~ I Application Number: 3028943 Certificate Number: 3028943 I I Section: Block: Lol: Building permil:30l.;;l.ocr BDC: n511 I ~ Described as a occupancy, wherein the premises electrical system consisting of ~ ~ electrical devices and wiring, described below, located inion the premises at: 3C)'SC! / ~ ~ First Floor, Second Floor, Detached Garage, Outside, ~ ~ A visual inspection of the premises electrical system, limited to electrical devices and wiring to the extent detailed ~ ~ herein, was conducted in accordance with the requirements of the applicable code andlor standard ~ ~ promulgated by the State of New York, Department of State Code Enforcement and Administration, or other ~ i authority having jurisdiction, and found to be in compliance therewith on the 21st Day of September, 2007. ~ ~ Name OTY Rate Ratio!! Circuit ~ ~ ~~~ ~ ~ total renovation ~ ~~~~~ ~ i'i!I Exhaust Fan 3 0 F.H.P. i'i!I ~ Hydro Massage Tub (Therapeutic) 1 0 ~ ~ Dish Washer I 0 1.2 KW ~ ~ Range 1 0 50 Amps ~ ~ Furnace 1 0 Gas ~ ~h~ ~ ~ 1 100 6 ~ ~ Wiring and Devices ~ ~ Outlet 46 0 Fixture ii!I ~ Fixture 46 0 Incandescent ~ ~ Outlet 102 0 General Purpose ~ ~ Receptacle 57 0 General Purpose ~ ~ Switch 53 0 General Purpose ~ ~ Dimmers 14 0 seal ~ ~ Paddle Fan I 0 ~ I Continued on Next Page 1 of 2 I I This certificate may not be altered in any way and is validated only by the presence of a raised seal at the location indicated. I IID.IID Town Hall, 53095 Main Road P.O. Box 1179 Soulhold, New York 11971-0959 Fax (631) 765-9502 Telephone (631) 765-1802 BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATION Date: /;2.../ ~//O 7 , I Building Permit No. ,6 J ~ 09 Owner: l'V\ ~ ~ Q . R~"if lease pnnt) Plumber: ~ r~p _ ~ef(d ~R- lease print) I certifY that the solder used in the water supply system contains less than 2/1 0 of 1% lead. ,~ Sworn to before me this .3 I day of j) e..C-- , 20 ~ l~ \-~\G~' a cK~ Notary Public,~ Y+o \ "-county VQIl.l.OI'9l NaIl" PubIc. SIIlt III New lllIII No. Oll06070081 CaoI.:::r.:.. SutIoIk~ /9-/0 F~'.e 'I. I " ~td I , ---.--...., 1'\ I" Town Hall 53095 Route 25 P.O. Box 1179 Southold, New York 11971-0959 James F. King, President Jill M. Doherty, Vice-President Peggy A. Dickerson Dave Bergen Bob Ghosio, Jr. Telephone (631) 765-1892 Fax (631) 765-6641 'i BOARD OF TOWN TRUSTEES TOWN OF SOUTHOLD _ __~TIFICATE OF COMPLIANCE ------ Date J anuarv 31, 2008 # 0292C THIS CERTIFIES that the renovation ofthe existing dwelling, gutters & drvwells At 575 Beachwood Rd., Cutchogue Suffolk County Tax Map # 116-4-21 Conforms to the application for a Trustees Permit heretofore filed in this office Dated 3/29/06 pursuant to which Trustees Wetland Permit #6339 Dated 4/19/06was issued, and conforms to all of the requirements and conditions of the applicable provisions of law. The project for which this certificate is being issued is for the renovation of the existing dwelling, gutters & drvwells. The certificate is issued to MARY R. RAYNOR owner ofthe aforesaid property. ~o<~ Authorized Signature Date: February 13, 2007 JAMES J. DEERKOSKI, P.E. 260 Deer Drive Mattituck, N.Y. 11952 (631) 298-7116 To: Town of Southold Building Dept. Re: Framing! Strapping Inspection Raynor 575 Beachwood Rd. Cutchogue, NY 11935 Permit#32209 To Whom It May Concern: After a Framing and Strapping inspection was preformed on the above mentioned property, it is deemed that all work performed was completed to plans and meets all state and local codes. Any other questions please call. FEB I 5 ? ' \ \ es }t\~OSki Nov"2DC:: JAMES J. DEERKOSKI, P.E. 260 Deer Drive Mattituck, N.Y. 11952 (631) 298-7116 To: Town of South old Building Dept. Re: First Foundation Inspection Raynor 575 Beachwood Rd Cutchouge, NY 11935 Permit# 32209 To Whom It May Concern: A First Foundation inspection was preformed at the above-mentioned construction site, the foundation was built as per plan, and meets all state and local building codes. Any other questions please call. .~ ~ \, '",. I \--$. mcere y \ , . \~ J=~ J.o.~; " APPEALS BOARD MEMBERS Ruth D. Oliva, Chairwoman Gerard P. Goehringer Vincent Orlando James Dinizio, Jr. Michael A. Simon Southold Town Hall 53095 Main Road. P.O. Box 1179 Southold, NY 11971-0959 Office Location: Town Annex IFirst Floor, North Fork Bank 54375 Main Road (at Youngs Avenue) Southold, NY 11971 http://southoldtown.northfork.net BOARD OF APPEALS TOWN OF SOUTHOLD Tel. (631) 765-1809. Fax (631) 765-9064 r- ('..li ~ ~; I " " " Ii, " Ute 2 I 2005 FINDINGS, DELIBERATIONS AND DETERMINATIO~' i MEETING OF NOVEMBER 17, 2005 L. io.;". ZB File No. 5711 - MARY RAYNOR Property Location: 575 Beachwood Road, Cutchogue CTM 116-4-21 ----=-!v~ !'. SEQRA DETERMINATION: The Zoning Board of Appeals has visited the property under consideration in this application and determines that this review falls under the Type II category of the State's List of Actions, without an adverse effect on the environment if the project is implemented as planned. PROPERTY FACTSIDESCRIPTlON: The applicant's 10,490 sq. ft. parcel has 35 feet aiong Beachwood Road (a private road), 196.51 feet along the westerly side line, 247.63 feet along the easterly side line, and 81.19 feet along the southerly line (buikhead). The lot is improved with a single-story cottage with decks, and detached accessory garage building, as shown on the March 15, 2005 survey prepared by Peconic Surveyors, P.C. BASIS OF APPLICATION: Building Department's April 15,2005 Notice of Disapproval, citing Sections 100-242A and 100-244 based on the Building Department's amended July 14, 2005 Notice of Disapproval, concerning a proposed second-story addition, for the reasons that the addition will increase the degree of nonconformance with side yard setbacks at less than 10 feet, less than 15 feet on the remaining side, and with lot coverage exceeding the code limitation of 20%. On June 13, 2005 the Building Inspector amended the Notice of Disapproval ('NO') to address the amendments, adding requests for new construction related to the first-floor replacement (without removing the existing foundation). and minor foundation area for a new deck addition. On July 14, 2005 the Building Inspector amended the Notice of Disapproval to address the new lot coverage calculated by the applicant's architect, replacing the June 13, 2005 calculations. FINDINGS OF FACT The Zoning Board of Appeals held a public hearing on this application on August 18, 2005 and October 20, 2005 at which time written and oral evidence were presented. Based upon all testimony, documentation, personal inspection of the property, and other evidence, the Zoning Board finds the following facts to be true and relevant: EXISTING NONCONFORMITIES: The existing house is a single-story seasonal building with porch and open, unroofed deck areas. The side setbacks and lot coverage are nonconforming under the current zoning reguiations. The lot coverage is nonconforming at 24.6+- percent, or 2580 square feet of building area (all buildings and foot prints). The house is 1.2 feet on west side and 2 feet on east side measured from the existing first floor at its closest points. Combined side yards are nonconforming at 3.2 feet for both. The setback to the bulkhead is nonconforming at 60+- feet to the house, and 50+- feet to the rear deck. AREA VARIANCE RELIEF REQUESTED: The applicant wishes to reconstruct the first floor for expanded, new living space, at 1.2 feet from the westerly lot line and 2 feet from the easterly lot line, and to add a partial second story, within the existing nonconforming side yards and nonconforming lot coverage. The extended lot coverage will be for a new deck area. Page 2 - November 17, 2005 Appeal No. 5711 - Mary Raynor CTM 116-4-21 ",. During the hearing, the applicant (Mrs. Raynor) explained the need to update the collage and increase the living area. Mrs. Raynor has resided at her family home on Cardinale Drive, and wishes to change the use of their beach collage from seasonal to full time, year-round occupancy, and to expand the living space (reconstructing and adding heat and other updated facilities). The collage was placed on this site more than 75 years ago, and about 1994, the applicant built a new breakaway foundation which met the Flood Emergency Management Act safety standards. The applicant also straightened the decks that were damaged due to floods over the years, and upgraded and expanded the sanitary system. The residents of the westerly adjacent house addressed their concerns to the Board, both in writing and at the public hearing, concerning the existing 1.2 ft. setback, proposed to be maintained for the new first floor on the westerly side of the home. In addition, the adjacent landowners suggested a four ft. minimum setback on the westerly side of the applicant's collage which provides access from the applicant's yard to the beach areas without trespassing through the house or over adjacent lands. No zoning variances were found for the immediate area relative to lot coverage or side yards, although other homes in the immediate area are improved with homes with side yard setbacks varying from 8 feet, 12 feet, and greater. REASONS FOR BOARD ACTION: On the basis of testimony presented, materials submilled and personal inspections, the Board makes the fOllowing findings: 1. Grant of alternative relief will not produce an undesirable change in the character of the neighborhood or a detriment 'to nearby properties. The applicant's plan is to reconstruct the first floor for expanded, new living space, at 1.2 feet from the westerly lot line and 2 feet from the easterly lot line, at its closest points. Also proposed is a new (partial) second story and extension for deck area. Although the lot width is only 35 feet along the road, the width of the lot at the center of the existing collage is 47+- feet. The new first floor will be 42 ft. wide, leaving a 1.2 ft. setback at the northwest corner of the new first floor and 2 feet at the opposite northeast corner. The applicant reduced a portion of the westerly side by two feet, which proposing a 2.8 ft. setback for the new first floor, instead of the existing 1 ft. of the older porch that exists. The first floor area is larger than the proposed second floor addition and is shown to be 7+- feet from the westerly side lot line at its closest point. The alternative granted in this variance will increase the setbacks, although remaining nonconforming, on the westerly side from 1.2 ft., to a minimum of 3 feet at the northwest closest corner, and from the existing 3.6 feet to a minimum of 5 feet on the easterly side, will be more conforming to the code requirements, and at the same time will provide a balance by reducing an effect to adjacent properties with increased setbacks, against the benefits given to the applicant for the reconstruction and expanded living space. The amount of floor space that would be reduced with the alternative setbacks is not substantial and is necessary for more confonmily into the side yards, since the existing side yard setbacks are substantially nonconforming. Also, the increased side setbacks would provide utilization of the open side yard, instead of accessing through the applicant's dwelling or over adjacent property for access purposes between the beach and the road side of the dwelling. Existing open deck areas may also be considered for conversion into necessary living space without building new construction within the sides. 2. The benefit sought by the applicant cannot be achieved by some method, other than an area variance. The property is unique in its dimensions and shape, with only 35 ft. frontage along the private road, widening to 81 feet along the waterfront (beach and bulkhead) along Peconic Bay. The lot is improved with a one-story collage with open, unroofed deck areas covering 21.6+- percent of the lot, plus an existing 320 sq. ft. garage, covering 3+- percent of the lot. The location of the sanitary system creates difficulty to expand in the front yard, leaving very little alternative except to convert the front open deck area (footprint) for additional living floor area. 3. The relief requested is substantial. The code requires a minimum of 10ft. minimum on a single side yard, and 15 feet on the opposite side yard, for a total minimum of 25 feet for both side yard setback area. The code also limits lot coverage to 20% of the lot size, and the lot is covered 24.6+- percent (2,580 sq. ft. of total building area including the 320 sq. ft. garage and large open deck areas that exist). 4. The difficulty has been self-created in that the applicant acquired the property with knowledge of the location of the existing collage and lot size and the nonconformities. J Page 3 - November 17, 2005 Appeal No. 5711 - Mary Raynor CTM 116-4;21 ':f"()I,)N;)Pr('\ 0."- VJ/ c.....""" \-O~,{J,0 CO- ov.e.fl-~ 5. No evidence has been submitted to suggest that the grant of alternative relief will have an adverse impact on the physical or environmental conditions in the neighborhood. This is a community of residences, some of which were built prior to the enactment of zoning in 1957. A few have been renovated, repaired or expanded in size over the years. 6. Grant of alternative relief is the minimum action necessary and adequate to enable the applicant to enjoy the benefit of reconstruction and alterations to the first floor and additions to the second floor, while preserving and protecting the character of the neighborhood and the health, safety and welfare of the community. RESOLUTION-OF THE BOARD: In considering all of the above factors and applying the balancing test under New York Town Law 267-B, motion was offered by Member Orlando, seconded by Member Goehringer, and duly carried, to DENY the variances as applied for, and to GRANT aiternative relief, with mOdifi~diagramS prepared~5 by Suter and Suter (submitted 9-28-05\. with a requested height shown at 32 f7e;ufrom the existing grade to the top of the ridge, ana utilizing the existing foundation, subject to the follOWing l;onOlllons: ./ There shall be a minimum setback of the requested 5.5 feet to the westerly lot line, for half the length on the seaward side of the house from the southwest corner, and minimum setback of three (3) feet to the westerly lot line, for the remaining half of the length (road-side, or southerly half between the north and south points), irl its closest points. ./2. There shall be a minimum setback of two (2) feet (existing setback) from the easterly side lot line, at its closest P9int. ~. se of existing foundation (without proposed excavation). Height not to exceed the requested 32 feet to top of ridge. xpansion into existing deck footprints shall be authorized for additional living area, without new ..-r;- Yf1 '/.J'r' pplication, when new construction setbacks conform to code and lot coverage does not exceed that IV I v~_ uthorized in this variance (25.5%). . \ B th side yards shall remain open and unobstructed at all times for clearance (related 'to emergency d fire vehicle access purposes). . hat drywells with a roof gutter system shall be maintained in good condition at all times for (;tainment of rainwater runoff. ' . eck areas shall be open to the sky. ~ . Lot coverage shall not exceed 25.5% of the lot size. 10. No building permit shall be issued until a new application for a building permit is submitted that meets all of the conditions set forth in this decision and is reviewed (for compliance with the conditions) by the A Chairperson or other representative in the Department of the Zoning Board of Appeals. 11. The owner or her authorized agent shall notify the Zoning Board of Appeals in writing in the event of a proposed change in circumstances, or new developments, related to the new construction, after issuance of this variance. The Zoning Board of Appeals reserves the right to require a new application with respect to any change in nonconformity that is restricted by this variance determination and the ~rovisions of the zoning code. This action does not authorize or condone any current or future use, setback or other feature of the subject property that may violate the Zoning Code, other than such uses, setbacks and other features as are expressly addressed in this action. Vote of the Board: Ayes: Members Oliva (Chairwoman), Goehringer, Dinizio, and Simon. (Member Orlando was absent.) This Resolution was ~UIY adopted (4-0)'Q ,,_ ~~, -< r.:o', fJ. rS1 Q.,.A. Q, uth D. Oliva, Chairwoman 12~05 ~jf~:9v\l ~ I }er<J1.tf~ C)~(, _ .~ .. -.,. ..- )n-oCf z- TOWN OF SOUTHOLD BUILDING DEPT. 765.1802 INSPECTION [ ] FOUNDATION 1 ST [ ] FOUNDATION 2ND [ ] FRAMING I STRAPPING [ ] FIREPLACE & CHIMNEY [ ] FIRE RESISTANT CONSTRUCTION [ ] ROUGH PLBG. [ ] INSULATION r0 FINAL Ie- ; [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT PENETRATION REMARKS: r~~) ~V*, EiJu~-J- p2~~ ~~,',;A-L ~~: ~~ c{ 6)it~,1JV 1;;..~7-07 INSPECTOR ~ ~ DATE ; ~o 9 Z- TOWN OF SOUTHOLD BUILDING DEPT. 765.1802 INSPECTION [ ] FOUNDATION 1ST [ ] FOUNDATION 2ND [ ] FRAMING I STRAPPING [ ] FIREPLACE & CHIMNEY [ ] FIRE RESISTANT CONSTRUCTION [ ] ROUGH PLBG. [ ] INSULATION [>(FINAL [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT PENETRAnON REMARKS: y F ~.~~ (;2.. -N2~/ Z ~, 6~~ ~_n ,~,,1 ~, ~ ck;-' ~Or-~, DATE I { r '9-6 - ~ 7 INSPECTOR * ~ R'. ~~_~ h4')~J---/~ ,..-- 3j-rJ?-& TOWN OF SOUTHOLD BUILDING DEPT. 765.1802 INSPECTION [ ] FOUNDATION 1 ST [ ] ~GH PLBG. [ ] FOUNDATION 2ND [t1"INSULATION [ ] FRAMING I STRAPPING [] FINAL [ ] FIREPLACE & CHIMNEY [] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUC'nON [ ] FIRE RESISTANT PENETRATION ,- REMARKS: V~ /7 clk../ cJtt ' DATE 5j~/7 J~ INSPECTOR ~/ ' - / , ,.. ! ~/ / -, ..::5 ;)-:2 0 r z TOWN OF SOUTH OLD BUilDING DEPT. 765.1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING I STRAPPING [] FINAL ~FIREPLACE & CHIMNEY [] FIRE SAFETY INSPECTION [ ] RRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: F~~) ~ ~ tr ~ ~ ok, , f! e., C-b ~ DL " DATE ~ - Lj- --- 07 INSPECTOR ~I ~ 3~d-O~ Z- TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1 ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND ,[>1: INSULATION [ ] FRAMING I STRAPPING [] FINAL [.>> FIREPLACE & CHIMNEY' A: [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: /f/~ /.~. -tj:.- ~ \\~"o~ pj,& -, ~~ "1r.v~ .,) ~ ti--j::;'v ~ /(~' -;JyJ1 'L ~ DATE S - ;;..tJ --f) I INSPECTOR ~ ~ 3?-~oi z.. TOWN OF SOUTHOLD BUILDING DEPT. 765.1802 INSPECTION [ ] FOUNDATION 1 ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING I STRAPPING [] FINAL D<J FIREPLACE & CHIMNEY [] FIRE SAFETY INSPECTION ,. [ ] FIRE RESISTANT CONSTRUCTION [ ] RRE RESISTANT PENETRAnoN REMARKS. ~~~.. ~.~.. .~4- ~~/~C7A ~ ~--6fk/fj ---~~ Cc<-.J\. . 't:i-- ~~ ~~ . ~ ~f *~~~~~ INSPECTOR ~ ~ , DATE S-)--J.,. ~ 07 ~~~A~7 3r~ 4 ~ TOWN OF SOUTHOLD BUILDING DEPT. 765.1802 INSPECTION [ ] FOUNDATION 1 ST [ ] FOUNDATION 2ND [ ] FRAMING I STRAPPING [ ] FIREPLACE & CHIMNEY [ ] RRE RESISTANT CONSTRUCTION REMARKS: ~ROUGH PLBG. [ ] INSULATION [ ] FINAL [ ] FIRE SAFETY INSPECTION [ ] RRE RESISTANT PENETRATION , ~ DATE S- 3 - D 7 INSPECTOR ~~ , .. FIELD INSPECTION REPORT DATE COMMENTS . . Ij)... vl'" v~ - s;; \'\J l::b :j:~ \J'~ ~. J' FOUNDATION (1ST) f .A~" " , ~oo. .) ./ ------------------------------------ FOUNDATION (2ND) I N/fl I i . , .Z lJI P /' ~ r t --a-e<- j/,JJ JI. J \ .e;;/tt/o 7 n." u. ~ / rJ/rr . .' A.17 ,/ ~ ~ ROUGH FRAMING & ' . ~ ' I~ t;; ~ PLUMBING '''"' ,-r;- -=,... ~ - A ~ /1 If J JJ...' 7'/_ r+ .rLJ\ /l A . . "" ;:; ~ f"\ ~~ ,.t1 l .';i-(f~...d rJb-" V Y-/ ,/1/ ~ l ce. ~ ,It- 5-~. 07 F-'- - PI ~J!.. n L> -'Ji' _____"",~'1! + L.D_~' " ~;J /A .1",.4 .'.<=#1 - IJC. ,L/ .'71-= A 'iir- ,,""~ :1" . ~ .' / fl..'..,1'J ~ 1 ~~~ //ff '//fI".LJ .~J)Q -7 /fI{)~d r'~ -cn--: c->o ,,---;r.'~/ ;' PP. D' n '" 0 .. }l4{o~P" _" # _ f} ., Vif ~ f'0 ~ : / f(. 'J.. 111 LJI.. -h J?Y1 .' " hnr, (fd ./'^ ~ , '. ~ n~ "JJ!J. ,~ , ~ ~ 77.""'/ f?1 A .j "d). r'" J/ 177>11 ({7 jv>-:t., _ a-.- ""'1' 1) '-p;~, ~ ,s... h-If__'b"1 Z:::o. /) ~/J .b, c:r ../Jl",../J - ." V..L- rL . ~ ;;; , ,,' >',0-/ /f') k-: "'/:' ._V:~.q - t'f), fJ.,./r-PI r =- . . .;..." ';;1iJ. "oil}, :__ p J-, A If './,U) t. 'l . - AA"- J) \I~J-lt, 1. I .;:::W A{r;~~ :L\ _ /Jol" n. () .~~ ~)" ~. . I MJ.).. , . '.0 }-:;' 0 ~ ,,_ 01. ....("./ , . Y\'-,....... 1..4- VI ~' " ./1 rvL. ~ _ .it'J IV~ /~ 4V ""'" "'... INSULATION PER N. Y. STATE ENERGY CODE \ ~-7-Dr7 n. ~ () ~ \ /Y L. , - ,-_ OY 12 0, ",., u rb- (^ f! -'.. ~.. "AA'-_ f//C "Jl]T ,J~.n ~ (/ v v } IJ ('" FINAL . ADDmONAL COMMENTS 1/4'1--46 f4.:c-' I h cVlP- ~ ~ J ~ /L, .11 .A ~ 12 - <; -/ '751 () --:Ii 1_. -[I - ("~ a:~O'Y<- I ~ -;::: .~ ~ rl " // . ~ ~ )J-07 /i..k-V, P.t:. ~. M!-'. 1.~ (.I o Ii A "M. r, ~ ,,? CJ r~ ~ . ~.,f;~~ '"" ~. GI ? ~ ,,{. . - l'" " , ~ 1 - ... v..i - . , ~ C...; .., 4 - 0 Z ..' = l'" \ . ;>-1::; '---"" .., .. '-. = N..,t:j l' ~ . ..., Board Of SoutholdTown Trustees SOUTHOLO, NEW YORK PERMIT NO. .&i.33C/ ..... DATE: ~!,,,~~19.,..~~06 ISSUED TO __._......~:'...J0.~~.?!.................._.._........... .....................-......... ............. Autlyllri!tttinn PUrsUllJ1t to the provisions of Chapter 615 of tlte laws of the. State of New Yem, 1893: and Chapter <404 of the laws of the . State of New Yorl: 1952: and the SoUthold ToWn OrdinanCe ell- tti!e4L''REGUl:ATlNeAND THE..PlActNG. OFaesmUGalO~S IN AND ON TOWN WATERS AND PUBUC lANDS andfl,e REMOVAL OF SAND, GRAVaOR OTHER MATERlAl.S..f.i.OM LANDS .UNDER TOWN WATERS;!~. and in accordance wtflt .the R lat' f 'I"L.. D.... d d pt'd t tin LU April'-.l9, eso Ion 0 me......r a 0 e a a mee 9....... on .......................... . }.~~. and in consideretion of the sum of $...?5..Q.:..~g._ peld by ..~EY...~~:r....... ................................ .............-.....................................-............>....... of . ..........~.1:~.I1()g\1e.......:............. N. Y. end subl":t to,fIK, Tenns and Conditions listed on the reverse side hereof, o~~'.ll"'d Town Trustees authorires and permits the foloW1ng: exls end ennlllo renovate the. first and second floors of the exiSting dwelling withln the . ~ footprint, with the qooditlon drywells and gutters are Installed to contain the roof run , and a row of slaked"'y bales Is placed down along the seaward side of the consedslructJon area, and as dej!lcted on the survey prepared by John T Metzger last rey' January 30, 2006. . al in accordance with the det el\ed speciflutions as presented in . tlte originating application. . IN WITNESS WHEReof. The said Board Of Trustees here. by causes Its Cor!Xlrat~ Seal to be affixed, and these p!1IS8IIts to be. subscribed by a maJority of the sald Board as of thtsdate. : ~ . ,.. " .f · '--~ , ' . ..1.1. it!L i" t ii.it~ ~t.~(lt" ftJ " " sf i l E: r r 'r ~Jlr !~r 1 i 1~ ji tit , I' I: I.f It ~ [ l ..Ii J I ~J1J~ ~ .I. Ir It ~.E ll~ fir g~f I t r g ijf i't ~ t f( 8tlr trIO l a. "" ~ l. . . irl.'Ul 1 : It it I! if!!1 l IIr : ,l~a.! l, i J~ If J1.,ltl! J, i g Ir i' ~ .a a. Ir ~ [a. =-1 2.! , l t~ J e. ~ t i [f ~ [ ~ .a.& t ~ , '.to' J r J: t i 1 .l r ft . t, i t 11111 ". ' . . ,. . >". '. " , ,I,'; ,(. ,di DEC PERMIT NUMBER 1-4738-00381/00003 FACILITY/PROGRAM NUMBER(S) . PERMIT EFFECTIVE DATE May 26, 2006 EXPIRATION DATE(S) Under the Environmental Conservation Law Mav 25, 2011 I o Article 15, Title 5: Protection of Wa- ters I TYPE OF PERMIT . New 0 Renewal 0 Modification 0 Permit to Construct 0 Permit to Operate o 6NYCRR 608: Water Quality Certification o Article 27, Title 7; 6NYCRR 360: Solid Waste Management o Article 15, Title 15: Water Supply o Article 17, Titles 7, 8: SPDES o Article 27, Title g; 6NYCRR 373: Hazardous Waste Management o Article 15, Title 15: Water Transport o Article 1 g: Air Pollution Control o Article 34: Coastal Erosion Management o Article 15, Title 15: Long Island Wells o Article 23, Title 27: Mined Land Reclamation o Article 36: Floodplain Management o Article 24: Freshwater Wetlands o Article 15, Title 27: Wild, Scenic and Recreational Rivers . Article 25: Tidal Wetlands o Articles 1, 3, 17, 19, 27, 37; 6NYCRR 380: Radiation Control PERMIT ISSUED TO TELEPHONE NUMBER Marv R. Ravnor (631 ) 298-8531 ADDRESS OF PERMITTEE 275 Cardinal Drive, Mattituck NY 11 952 CONTACT PERSON FOR PERMITTED WORK TELEPHONE NUMBER NAME AND ADDRESS OF PROJECT/FACILITY Ravnor Prooortv, 575 Beachwood Road Cutchooue NY LOCATION OF PROJECT/FACILITY SCTM # 1000-116-4-21 COUNTY TOWN WATERCOURSE NYTM COORDINATES Suffolk Southold Peconic Bav E:710.2 N:4540.5 Description of Authorized Activity Renovate and construct a second story addition onto the pre-existing single family dwelling within the footprint of the existing dwelling, porch and decks. Remove a portion of the existing deck and construct a first and second story deck. All work shall be performed in accordance with the plans prepared by Peconic Surveyors, P.C. last revised on 4/24/06, and stamped NYSDEC approved on 5/26/06. .lIr By acceptance of thiS permit, tho penmttee agrees that tho penmt IS contingent upon strict compliance W1thll1e ECL, all applicable ro ulations, tho General Conditions s clfied see 2 .4 an al CondItions included as rt of this rmit. DATE Ma 26 2006 Page 1 of4 95-20-1 (818n-9d New York State Department of Environmental Conservation o NOTICE '8 ~ The Department of Environmental Conservation (DEC) has issued permit(s) pursuant to' the Environmental Conservation Law for work being conducted at this site. For further information regarding the nature and extent of work approved and any Departmental conditions on it, contact the Regional Permit Administrator listed below. Please refer to the permit number shown when contacting the D. () -z 1-~73ca"oo3S' DDQglona~mitAdministrator . Permit Number JOHN -vV. PAVACIC Expiration Date NO E: This notice is NOT a permit TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL SOUTHOLD, NY 11971 TEL: (631) 765-1802 FAX: (631) 765-9502 www.northfork.net/S BUILDING PERMIT APPLICATION CHECKLIST Do you have or need the following, before applying? Board of Health 4 sets of Building Plans Planning Board approval Survey Check Septic Form N.Y.S.D.E.C. Trustees Contact: Mail to: -,,// PERMIT NO. 3<9c9oq Expiration /-/3 ,20~ Phone,)?&,. 853 J r-- . ~I~(:~~~\\?f- . I r~[~ ~ -~...?'i' /1111 J" h,j . OR II 2005 ! ~~LICATION FOR BUILDING PERMIT L i.,"[J. i DEP~ 1 __TC\"",,~ILO~c.;r.~T1-f9J,_'L-J Date INSTRUCTIONS ,20_ a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale. Fee according to schedule. b. Plot plan showing location oflot and of buildings on premises, relationship to adjoining premises or public streets or ar~as, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application, the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e. No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim, the Building Inspector may authorize, in writing, the extension of the permit for an addition six months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County, New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances, building code, housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. (Sign re of applicant or nam if a corporation) 0(/)~~:n~ b~ f'Y\C>.-tf .. . ~. ~ . . \ \ C\ :'-d, (Mailing ad ress of appllcant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder 6~~eI Name of owner of premises -----.Y'f\ ~~~ k. PO.!'-I \,,'t'~~/' (As on th'e tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. Plumbers License No. Electricians License No. Other Trade's License No. 1. ~ Hamlet County Tax Map No. 1000 Section I \ I..:, Subdivision Block~ Filed Map No. (Name) Lot .;L r Lot 2. State existing use and occupancy of premises and intended use lJ!ld occu ancy of proposed construction: a. Existing use and occupancy , O' \ Ie <-, (' ~eV\ C E' b. Intended use and occupancy Slr-s \e ~Ol~l\~ ~e'S( AeJ\ce . 3. Nature of work (check which applicable): New Building Repair Removal Demolition Addition Other Work Alteration X 4. Estimated Cost ~ a ~l)) DCO (Description) Fee (To be paid on filing this arlicatiOn) Number of dwelling units on each floor r'I q 5. If dwelling, number of dwelling units If garage, number of cars I Lf~ 11\ ~ cS . 6. Ifbusiness, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front L4 Lf. Height I '3 Number of Stories ~ Dimensions of same structure with alterations or additions: Front ~ ". Rear--'i!:!-- Depth 3,c; Height 3 I Number of Stories :z Rear Depth 8. Dimensions of entire new construction: Front Height Number of Stories Rear Depth 10. Date of Purchase 35 ~fDS Rear ,:;) ;;Z ;;2.. Name of Former Owner -A ~<lU .t1 "'<.-\-\-Q ~e~ \ 211" t\~ cJ 5'1 Depth 9. Size oflo!: Front \ ~ O,~ 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation? YES_NO_ ? I 13. Will 101 be re-graded? YES-.X NO_Will eAces, fill be removed from premises? YES_ NOl c).)SC~ \'<\0..\ ~(. 'Phone No. Phone No ~me No. 14. Names of Owner of premises ~~ \<~~ \'C( Name of Architect 5u\p(' -S ::\.ei Name of Contractor Address Address Address d- 9:~ ,~S?:> \ Co S''J, - ~,<;; ')0 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES ---X-- NO _ * IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES ~ NO_ * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. STATE OF NEW YORK) SS: rz/ being duly sworn, deposes and says that (s)he is the applicant ividual SIgning contract) above named, (S)He is the OlAmIf/ (Contractor, Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. Sworn to before me this Cfh day of 20~ ~ ,(J ~.~ 'gnature of Applicant &USAN J. NAGY ~Jotary Public Stale of New York No. 4896735 Qualnled In Suffolk County Commission Expires May 201!1 Phone: (631) 444-0365 . FAX: (1331) 444.0360 Website: www,decstatenyus ""','>0' -- ._, 'I -, ~-"', ...~, ....,,, .......... . ,............, ~."'" 'J ..." ,",Vt'. !..' \ \ r JV".,)"tV;;J DenisI') M. ShOerHj:-i CClmnlissicner PL;RJ\1IT I\fODI.FICATION ._~,.,~"..,".,--~..._,""_._"_.~---_.._,--,,,,._,,~-~,,-"..._.._.. Ms. Mary R. Raynor 275 Cardinal Drive Mattituck NY 11952 November 3, 2006 I NYSDEC #1-4738-00381/00003 RaY'Dor Property 5, 75>Btlll:bwol')d Road ' ,.,.... "". MaUituck !'Iy SCTM # 1 (JO()-II 6-4-21 j>ermit F:xpiration: 5/25/2011 r DEe 2 2 ?'lS Dear Penllittec: i , __..J Your recent request to modify tbe above pennit has been reviewed pursuant to 6 NYCRR Part 621 (Uniform Procedures Regulations), It has been determined that the proposed modifieations will not substantially change the scope oflhe permitted actions or existing permit conditions, Therefore, the permit ill J,jJodificd to authorize: ReCollstmctioll aJld relocation of thc existing garage 6 inches to the south and west as shown on the survey by Johl1 T, rVlet/gel' last revised 011 9/\ 5/06. and stamped NYSDEC approved on I J')l06. TIllS letter is a modifl.catiolllo the ongmal pel1l1lt, and as such, shall be available at the Job site whenever aulhonzed work is in progress, ,.,.~"".,,,,.,,,-~ All other terms and conditions relllaln as ~nfen ill the original pcr'mit, /,-1 I / Sinccn:ly,/ I f ! , \. j) I' I ,. john';\. Wieland Deputy Regional Permit Administrator -\ \,'..........,_.....--" . I:,,:: \,1arl!h,;' Ilabitdll:lr()\(.'cti()!1 file . Permit Nwnber REScheck Compliance Certificate New York State Energy Conservation Construction Code REScheckSoftware Version 3.6 Release I Data filename: C:\Program FileslChecklRESchecklRaynor.rck Checked ByIDale PROJECT TITLE: Raynor COUNTY: Suffolk STATE: New York HDD: 5750 CONSTRUCTION TYPE: Detached I or 2 Family HEATING TYPE: Non-Electric WINDOW /WALLRATIO: 0.21 DATE: 06/29/06 DATE OF PLANS: 6-21-06 COMPLIANCE: Passes Maximwn UA = 525 Your Home UA = 508 3.2% Better Than Code (VA) Ceiling I: Flat Ceiling or Scissor Truss Ceiling 2: Cathedral Ceiling (no attic) Skylight I: Wood Frame:Double Pane with Low-E Wall I: Wood Frame, 16" o.c. Window I: Wood Frame:Double Pane with Low-E Floor I: All-Wood 10istlTruss:Over Unconditioned Space Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value IT-Factor .llA 892 30.0 0.0 31 639 30.0 0.0 21 10 0.350 4 3156 19.0 0.0 149 675 0.350 236 1531 21.0 0.0 67 ] COMPLIANCE STATEMENT: The proposed b ilding represented in this docnment is consistent with the building plans, specifications, and other calculations sub . tted with tIns pennit application. The proposed systems have been designed to meet the New York State Energy C servation Construction Code requirements. When a Registered Design Professional has stamped and signed tins page, ley are attesting tlllil 10 tile best of his/her knowledge, belief, and professional judgment, such plans or spe . ns are in compliance Witll this Code. Il) Date b-Zq-o~, BuilderlDesigner REScheck Inspection Checklist New York State Energy Conservation Construction Code REScheckSoftware Version 3.6 Release 1 DA TE: 06/29/06 PROJECT TITLE: Raynor Bldg. Dept. Use Ceilings: I. Ceiling I: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation Comments: 2. Ceiling 2: Cathedral Ceiling (no attic), R-30.0 cavity insulation Comments: Above-Grade Walls: [] I. Wall I: Wood Frame, 16" O.c., R-I9.0 cavity insulation Comments: Windows: [] ]. Window I: Wood Frame:Double Pane with Low-E, U-factor: 0.350 For windows without labeled U-factors, describe features: # Panes_Frame Type Thermal Break? [ ] Yes [ ] No Comments: Skylights: [] I. Skylight I: Wood Frame:Double Pane with Low-E, U-factor: 0.350 For skylights without labeled U-factors, describe features: # Panes_ Frame Type Thermal Break? [ ] Yes [ ] No Comments: Floors: [] I. Floor I: All-Wood Joist/Truss:Over Unconditioned Space, R-2I.0 cavity insulation Comments: Air Leakage: Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. Recessed lights must be I) Type IC rated, or 2) installed inside an appropriate air-tight assembly with a 0.5" clearance from combustible materials. Ifnon-IC rated, the fixture must be installed with a 3" clearance from insulation. Vapor Retarder: [] Required on the warm-in-winter side of all non-vented framed ceilings, walls, and floors. Materials Identification: ] Materials and equipment must be installed in accordance with the manufacturer's installation instructions. ] Materials and equipment must be identified so that compliance can be determined. Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. ] Insulation R-values and glazing U-factors must be clearly marked on the building plans or specifications. Duct Insulation: ] Supply ducts in unconditioned attics or outside the building must be insulated to R-8. ] Return ducts in unconditioned attics or outside the building must be insulated to R-4. ] Supply ducts in unconditioned spaces must be insulated to R-8. ] Return ducts in unconditioned spaces (except basements) must be insulated to R- ] Return ducts in unconditioned spaces (except basements) must be insulated to R-2.. Insulation is not required on return ducts in basements. Duct Construction: [] All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives), mastic-plus-em bedded-fabric, or tapes. Tapes and mastics must be rated UL 181A or UL 18lB. Exception: Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pal. The HV AC system must provide a means for balancing air and water systems. Temperature Controls: [] Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space temperature set point of the largest zone. Electric Systems: Separate electric meters are required for each dwelling unit. Fireplaces: ] Fireplaces must be installed with tight fitting non-combustible fireplace doors. ] Fireplaces must be provided with a source of combustion air, as required by the Fireplace construction provisions of the Building Code of New York Stale, the Residential Code of New York Slale or the New York City Building Code, as applicable. Service Water Heating: Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. Insulate circulating hot water pipes to the levels in Table I. Circulating Hot Water Systems: [] Insulate circulating hot water pipes to the levels in Table] . Swimming Pools: [] All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: HV AC piping conveying fluids above 105 "F or chilled fluids below 55 "F must be insulated to the levels in Table 2. . . Heated Water Temneratnre ( F) 170-180 140-160 100-130 Table 1: Minimum Insulation Thicknessfor Circulating Hot Water Pipes. Insulation Thickness in Inches bv Pine Sizes Non-Circulating Rnnonts Circulating Mains and Rnnouts lJJ) to I" lip to 1 25" I 5" to 2 0" Over 2" 0.5 1.0 1.5 2.0 0.5 0.5 1.0 1.5 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thicknessfor HVAC Pipes. Fluid Temp. Insulation Thickness in Inches b,y Pipe Sizes Pininl! System Tvnes Range (F) 2" Rllnouts 1" and Less I 25" to 2" 2 5" to 4" Heating Systems Low Pressureffemperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate (for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only) . Permit Number REScheck Compliance Certificate Checked BylDate New York State Energy Conservation Construction Code REScheckSoftware Version 3.6 Release I Data filename: C:lProgram FileslChecklRESchecklRaynor.rck PROJECT TITLE: Raynor COUNTY: Suffolk STATE: New York HDD: 5750 CONSTRUCTION TYPE: Detached I or 2 Family HEATING TYPE: Non-Electric WINDOW I WALL RATIO: 0.21 DATE: 06/29/06 DATE OF PLANS: 6-21-06 COMPLIANCE: Passes Maximum UA = 525 Your Home UA = 508 3.2% Better Than Code (UA) Ceiling I: Flat Ceiling or Scissor Truss Ceiling 2: Cathedral Ceiling (no attic) Skylight I: Wood Frame:Double Pane with Low-E Wall I: Wood Frame, 16" o.c. Window I: Wood Frame:Double Pane with Low-E Floor 1: All-Wood Joist/Truss:Over Unconditioned Space Gross Glazing Area or Cavity Cont. or Door Perimeter R- Value R-Valne lJ-Factor l!A 892 30.0 0.0 31 639 30.0 0.0 21 10 0.350 4 3156 19.0 0.0 149 675 0.350 236 1531 21.0 0.0 67 COMPLIANCE STATEMENT: The proposed building represented in this document is consistent with the building plans, specifications, and other calculations submitted with this pertuit application. The proposed systems have been designed to meet the New York State Energy Conservation Construction Code requirements. When a Registered Design Professional has stamped and signed this page, they are attesting that to the best of his/her knowledge, belief, and professional judgment, such plans or tions are in compliance with this Code. BuilderlDesigner .it- ..'~';'M;"" Date&-/L q - (Jb REScheck Inspection Checklist New York State Energy Conservation Construction Code REScheckSoftware Version 3.6 Release I DATE: 06/29/06 PROJECT TITLE: Raynor Bldg. Dept. Use Ceilings: I. Ceiling I: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation Comments: [ 2. Ceiling 2: Cathedral Ceiling (no attic), R-30.0 cavity insulation Comments: Above-G .ade Walls: [] 1. Wall I: Wood Frame, 16" o.c., R-19.0 cavity insulation Comments: Windows: [] 1. Window I: Wood Frame:Double Pane with Low-E, U-factor: 0.350 For windows without labeled U-factors, describe features: # Panes_ Frame Type Thermal Break? [ ] Yes [ ] No Comments: Skylights: [] 1. Skylight I: Wood Frame:Double Pane with Low-E, U-factor: 0.350 For skylights without labeled U-factors, describe features: # Panes_Frame Type Thermal Break? [ ] Yes [ ] No Comments: Floors: [] 1. Floor I: All-Wood Joist/Truss:Over Unconditioned Space, R-21.0 cavity insulation Comments: Air Leakage: Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. Recessed lights must be I) Type IC rated, or 2) installed inside an appropriate air-tight assembly with a 0.5" clearance from combustible materials. Ifnon-IC rated, the fixture must be installed with a 3" clearance from insulation. Vapor Retarder: [] Required on the warm-in-winter side of all non-vented framed ceilings, walls, and floors. Materials Identification: Materials and equipment must be installed in accordance with the manufacturer's installation instructions. Materials and equipment must be identified so that compliance can be determined. Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. Insulation R-values and glazing V-factors must be clearly marked on the building plans or specifications. Duct Insulation: ] Supply ducts in unconditioned attics or outside the building must be insulated to R-8. ] Return ducts in unconditioned attics or outside the building must be insulated to R-4. ] Supply ducts in unconditioned spaces must be insulated to R-8. ] Return ducts in unconditioned spaces (except basements) must be insulated to R- ] Return ducts in unconditioned spaces (except basements) must be insulated to R-2.. Insulation is not required on return ducts in basements. Duct Construction: [] All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives), mastic-plus-em bedded-fabric, or tapes. Tapes and mastics must be rated UL 181A or UL 181B. Exception: Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in. W.g. (500 Pal. [] The HV AC system must provide a means for balancing air and water systems. Temperature Controls: Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space temperature set point of the largest zone. Electric Systems: [] Separate electric meters are required for each dwelling unit. Fireplaces: ] Fireplaces must be installed with tight fitting non-combustible fireplace doors. ] Fireplaces must be provided with a source of combustion air, as required by the Fireplace construction provisions of the Building Code of New York State, the Residential Code of New York State or the New York City Building Code, as applicable. Service Water Heating: Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. ] Insulate circulating hot water pipes to the levels in Table I. Circulating Hot Water Systems: [] Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [] All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [] HV AC piping conveying fluids above 105 "F or chilled fluids below 55 "F must be insulated to the levels in Table 2. Heated Water Table 1: Minimum Insulotion Thickness for Circulating Hot Water Pipes. Ins1l13tion Thickness in Inches bv Pine Sizes Non-Circulatinl! Runouts Circulatine Mains and Runouts IIp to ]" Un to 1 25" 1 5" to 2 0" Over 2" 0.5 1.0 1.5 2.0 0.5 0.5 1.0 1.5 0.5 0.5 0.5 1.0 Temnernhlre ( F) 170-180 140-160 100-130 Table 2: Minimum Insulation Thicknessfor HVAC Pipes. Fluid Temp. Insulation Thickness in Inches hv Pipe Si7.es Piping: Svstem rxPes Range (F) 2" Rnnonts ]" and Less I 2511 to 2" 2 511 to 4" Heating Systems Low Pressurerremperature Low Temperature Steam Condensate (for feed water) Cooling Systems Chilled Water, Refrigerant, and Brine 201-250 1.0 1.5 1.5 2.0 120-200 0.5 1.0 1.0 1.5 Any 1.0 1.0 1.5 2.0 40-55 0.5 0.5 0.75 1.0 Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only) II! CONCRETE SURVEY OF PROPERTY GAR, ~ 14.3 2.7W AT CUTCHOGUE ?i;l FR. TOWN OF SOUTHOLD ~~ /!! ).. .. ~ OJ ~ ~ GAR. SUFFOLK COUNTY, N.y. ... ~ '5 W ~ ?1 11 /) 14.3' 1000-116-04-21 ~ I'J ::'5 3i GAR. ~ SCALE: 1. 20' ~ 2.S'W MARCH 15. 2005 ~ " ~ ~ ~ S ~ ~ DE:CK ~ HSE. 2.0'W <::l ~ ~ ~ T STY. i5? ~ 1.0' F!? HSE. ;;:: ~ ~ ~ ~ ~ I ~ ~ .0 DE:CK :5 j{J ~ ... ... ::t ~ ~ f ~ ~ ~ ).. ~ i:! ~ ~ Os ~ ~ ~ N BEACHTYOOD CI'II"a'tl ROAD .a'l !!..ONUAlCNr S81 "55'50-c 35.00' o ""lD? "'TEI? GWA'fl. DR/~WA y N1JL ~ 'JJCHE,I./J) (IN"" ~ o .0 o :- ~ ~ ~ '"" '~ ..... "2.0 ~~ ~O %-"<\ ~~ '7')~ ~~ ~O ~ ~~ ... ~ '\ ~ o~\c f~C OF.~~'t ~~i ANY AL TERA 710N OR ADDI110N TO THIS SURlEY IS A \fa.A T10N OF S<C1/CN 7209()F THE NE:W YQW( STA TE BJUCA 1/CN LAw. EXCEPT AS PER S<CTlON 7209-SVBOI"SION 2. ALL CERTI17CA 1/CNS HERCON ARC VAliD FOR 1HIS MAP AND COPES 11ERCOF ONLY IF SAJ() MAP OR COPIES BEAR THE IMPRESSED SE.4L OF THe SUR\E"'r'I:W rtHOSE SIGNA. TURE: APPEARS HEREON. STREET ADDRESS: 575 BEACHWOOD ROAD . TO NEW E 1520 K AvENU SU~ CERTIFIED TO: MARY RA YNOR CHICAGO Tl71.E INSURANCE COMPANY 05-116 N ~ ?5 ~ ~ ii S ~ ~ ~ H ~ ~ ~ ;., ~ I! I rW-_._AD) (111........- ,/" /' ~ ~ SBO"16'95-W 8.02 -t-. ()IIGfltJl.I<IO"~.. ~. ......w.... No. ~. ~ -a ~. ~~ ~ ~ ~ ~~ .\\ \ ~ c::. ~ ~:t ~ ~~ ~ "60 ~ AREA=10,490 SQ. FT. TO TIE UNES ANY ALlBlAlIClII OR ADOIlIClII III THIS Sl.WIEY IS A VIOI.ATICN OF SEC71DN 72t>>OF 1HC NEW )QIlI( $TA 7F E1JUCA1ION LAl<< EXal'T AS _ SEC1ION 72OII-SUlDIIISION Z. AU. CERMCA 1IONS HEREON ARE VAL.f) FOR THIS MAP AND CCI'/ES 1HCREOF CWt Y IF S4.I) ItIAP OR CQ'lE5' BEAR THC M J.....;>;X.U SEAL OF THE SUR\E'l"D1l _ SIGNA 1IJRt: APPCAIlS HEREON. WETLANOS 'i.. 'i.. STREET ADDRESS: 575 BEACH WOOD ROAD CmnFIED TO: MARY RA YNOR CHICAGO nTLE INSURANCE COMPANY . . . r"1l:'r (PIJ8Uc If A IE DIj'.ACHIYOOD" /N STReE"r) CPIr"AY, ROAD IIAll ~~T 581 'SS'SO-E 3S.00' DEe 5 ?r .... L_'. '"' ~ o IfATCR AleTCR . TO NE:W c 1520 A VE:NU~ SU~ GRAm OR/IF....' ~ j ~ ! ill >1SnNG GARAGE SURVEY OF PROPERTY AT CUTCHOGUE TOWN OF SOUTHOLD SUFFOLK COUNTY, N. y: 1000-116-04-21 SCALE: 1- 20' MARCH 1S, 200S APRIL 7, 2005 (ELEVA nONS) MA Y 17, 2005 (PROPOSEO AOOtnONS) JUNE 27. 2005 (ADD/nON) SEPTEMBER 2, 2005 (LOT COVERAGE) SEPTEMBER 16, 2005 (REVISIONS) SEPTEMBER 23, 2005 SEPTEMBER 27, 2005 (AOOtnONS) OCTOBER 18, 2005 (AOOtnONS) JANUARY 30, 2006 (REVISIONS) APRIL 24, 2006 (REVISIONS) SEPTEMBER 15, 2006 (PROPOSEO GARAGE) NOVEMBER 6, 20 T COVERAGE) ~ NOVEMBER 30, 006 ~ OUNDAnON LOCAnON) &. Q:: ./ .---., s/---- / <{ ~ ;V OJ .... ~ <0 " Ii! ..,. ~ ~ ~ 10.0' ~ ~ ~ .. ... FNDTN. 2.J'W 22.5 " " " II ~ ~" "'!.\ !E", i;j CONe. FOUNDA TlON <0 ,L;'7'-Rr~ ~ (~ ~ '" -.J 26.2' ;., S! ,/" ,/" 15l ,/" >. I i ~ EXISTING FINISHED FLOOR EL. 9.4 MEETS FEMA REGULA TlONS 2005 OF EL. 8 BOTTOM OF FOOTINGS EL. 3.1 MEETS N Y 5 BUILDING CODE OF 3' ~ . Q f:) Q f"- Ig FLOOD ZONE AE (el 8) FIRM 36103C0482 ELEVA TlONS REFERENCED TO N.G. V.D. FILL REQUIRED=O YARDS DWELLING CONFORMED TO FEMA REGULA TlONS EXISTING 7st. FLOOR ELEVA TlON = 9.4' PROPOSED 1st. FLOOR ELEVA TlON=9.4' PROPOSED LOT COVERAGE GARAGE 320 S.F. / 10490 = 3.1% HOUSE AFTER CONSTRUCTION 2300 S.F. / 10490 = 21.9% TOTAL COVERAGE 2620 5.F. / 10490 = 25% NO. 49618 .p~R. \'Y\ 1"- ~ :s 2-2-<0 I