HomeMy WebLinkAbout31908-Z
FORM NO. 4
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
Office of the Building Inspector
Town Hall
Southold, N.Y.
CERTIFICATE OF OCCUPANCY
No: Z-32534
Date: 08/20/07
THIS CERTIFIES that the building FIRE REPAIR & ALTERATION
Location of Property: 58855 CR 48
(HOUSE NO.)
County Tax Map No. 473889 Section 44
GREENPORT
(STREET) (HAMLET)
Block L- Lot 22
Subdivision
Filed Map No.
Lot No.
conforms substantially to the Application for Building Permit heretofore
filed in this office dated
APRIL 3, 2006 pursuant to which
Building Permit No. 31908-Z
dated
APRIL 13, 2006
was issued, and conforms to all of the requirements of the applicable
provisions of the law. The occupancy for which this certificate is issued
is FIRE REPAIR AND ALTERATION TO AN EXISTING MOTEL AS APPLIED FOR.
The certificate is issued to LEVIN FAMILY LTD PARTNERSHIP
(OWNER)
of the aforesaid building.
SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL
N/A
ELECTRICAL CERTIFICATE NO.
112900C
08/15/07
PLUMBERS CERTIFICATION DATED
07/31/07 WILLIAM GREMLER
Rev. 1/81
Form No.6
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
TOWN HALL
765-1802
APPLICATION FOR CERTIFICATE OF OCCUPANCY
This application must be filled in by typewriter or ink and submitted to the Building Department with the following:
A. For new building or new use:
I. Pinal survey of property with accurate location of all buildings, property lines, streets, and unusual natural or
topographic features.
2. Pinal Approval from Health Dept. of water supply and sewerage-disposal (S-9 form).
3. Approval of electrical installation from Board of Fire Underwriters.
4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of I % lead.
5. Commercial building, industrial building, multiple residences and similar buildings and installations, a certificate
of Code Compliance from architect or engineer responsible for the building.
6. Submit Planning Board Approval of completed site plan requirements.
B. For existing buildings (prior to April 9, 1957) non-conforming uses, or buildings and "pre-existing" land uses:
I. Accurate survey of property showing all property lines, streets, building and unusual natural or topographic
features.
2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is
denied; the Building Inspector shall state the reasons therefor in writing to the applicant.
New Construction:
C. Fees
I. Certificate of Occupancy - New dwelling $25.00, Additions to dwelling $25.00, Alterations to dwelling $25.00,
Swimming pool $25.00, Accessory building $25.00, Additions to accessory building $25.00, Businesses $50.00.
2. Certificate of Occupancy on Pre-existing Building - $100.00
3. Copy of Certificate of Occupancy - $.25
4. Updated Certificate of Occupancy - $50.00
5. Temporary Certificate of Occupancy - Residential $15.00, Commercial $15.00
Date.t1u1. 'D; ~OtJ)
/' (check one)
r:;v~If/J~
.
Location of Property:
Old or Pre-existing Building:
~gg- 5") 21-' IfY
House No. Street
Owner or Owners of Property: J t:(I,,,) 1itJ"" J... J.'/''II6ee!
f
Suffolk County Tax Map No 1000, Section Lt7.? 837
Subdivision
Pennit No. 31%~--z.. Date of Permit. '1/ I'd) Ov
Hamlet
hr7/VlHri.tb
.
Block ~4 .
1
Lot
-22-
Filed Map.
Lot:
Applicant: U.......... J.ev"'; )Ji~.lro/j,~
Health Dept. Approval:
Planning Board Approval:
Request for: Temporary Certificate
Pee Submitted: $ ~ tJp
~-:.r.. -::, d- <; ~ '-\-
~ c:..- '13t)0C>
Underwriters Approval:
Pinal Certificate: (check one)
~4r
Applicant Signature
James F. King, President
Jill M. Doherty, Vice-President
Peggy A. Dickerson
Dave Bergen
Bob Ghosio, Jr.
Town Hall
53095 Route 25
P.O. Box 1179
Southold, New York 11971-0959
Telephone (631) 765-1892
Fax (631) 765-6641
BOARD OF TOWN TRUSTEES
TOWN OF SOUTHOLD
CERTIFICATE OF COMPLIANCE
# 0239C
Date August 17,2007
THIS CERTIFIES that the reconstruction of the central building with an addition of a second-
stOry. reconstruction of existing deck, and drainage system
At 58775 Route 48. Greenport,
Suffolk County Tax Map # 44-2-22
Conforms to the application for a Trustees Permit heretofore filed in this office
Dated 9/7/05 pursuant to which Trustees Permit # 6196ADated 9/21/05
Was issued, and conforms to all ofthe requirements and conditions ofthe applicable
provisions oflaw. The project for which this certificate is being issued
is for the reconstruction of the central building with an addition of a second-story,
reconstruction of existing deck. and drainage system.
The certificate is issued to ELLEN LEVIN WIEDERLIGHT owner of the
aforesaid property.
~51'~
Authorized Signature
Rue 15 07 11:228
El.o~~ic81 Insp.ceion
6312866683
1aJ001/001
p.l
08/17/2007 08:40 FAX
6312180888
FINALPHASE
Electrical Inspection Certificate
Ique D.",
11/'1512007
ElectrIcIlllnspectian Service, In...
'7& Dunton Averlue
east Pakhogw, New Y...... 11772
(WI__2
ApplIOlltlon Number
112900c
lasued To;
Street:
Villaga:
Section:
Sound View Inn Inc.
58775 Rovte 48 - Sound Avenue
Greenport Zip:
11944
Town; Southold
Block:
Lot:
Contractor: Final Ph... Electric eL) LIe;;, # 4600-E
Was ....tn_ """ Iou"" 10 be In compIa_l*ilh Ihe NoIIiomtIIiIeolrloaI Code.
Ixl eanmePClel ,1".1 NVD..r.0t8 '-I Pool I;(] 1etFloor i!CIIRd",,' IXI &S_nt i I Hot Tub
o ""aielanti", I I Dot. GlIrage I I Atele r I 2nd Floor Ix I Ou&d...., L I Addltfon I ~1 lIu""'V
- - --.-
Swmoh.. _epract.. F~ (JR H..._ AIC Fa".
112 245 104 35 2
DIsh_her W'ultedAmps OryedAmpa OVen R""";Amp* Mi<:rowa"..
1
FIImace on Ga. Cirr:ut.""". Smoke Detector Bell Trensfurmw
X X 35
If.,.,. Amps Ph.. UGlOH JetuD' TeftIVI..;on CO~r
1 600 3 [!ill
Bldg. Psrmit:
Oth.r EqUIpment ~ III \ I , --'--
BOcircuits /4 exitsT2 exItS em eombo/26 ac" JJ ~
208 voll receptacles
Hugo S. unli '
President
I
L
Rough ln~on; 11108/2008
InspO<Ulr. J(I/UI Me ....tIlo" III
, -'
AnalInspectjon;
lnopm;lo"
08lO8l2OO7
Anthony J, Rich."" II
Thl, call1lleete mUll not be all8f1ld in AlII' ".Mer, In_c:lOI$ m.,y.... idenUt'llld by their er9d.nllalo.
Town Hltll, 53096 Main RlUld
P. O. Box 1179
Southold, NewYorlo; 11971
Fax (51S) 785,1823
T.lephone (518) 785.18(12
OFFICE OF THE BUILDING INSPECTOR
TOWN OF SOUTHOLD
CBR'l'IFICATIOl\f
IM'1'I: 1.3J. {)7
8uilding Permit No. 3 J Q087;:
Owner: LeViI')'" ~II~ Par-lurJShtfJ L{fYJ,ftd
(please pr nt
Plumber: ~i /I iCUl1 efft'jV1/er-
plaue print)
I certify that the solder USed in the water supply .yste.
contain. 1... than 2/10 of l' l..d.
--1
V
(Plumbers Signature)
SWorn to betor. me this
JIU "YOf~ . ,/~,,"1
Notary Public I ,?fi> Ie::.- County
~J V'~
ELA1NET. VILLANO
Nota Public, State of New Vorl<
No. 07V16029229. Suffolk OO~ q
Commission Expires Aug. 9, I
FORM NO. 3
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
Town Hall
Southold, N.Y.
BUILDING PERMIT
(THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL
COMPLETION OF THE WORK AUTHORIZED)
PERMIT NO.
31908 Z
Date APRIL
13, 2006
permission is hereby granted to:
JACK J & ORS LEVIN
21695 SOUNDVIEW AVE
SOUTHOLD,NY 11971
for :
FIRE REPAIR AND ALTERATION TO AN EXISTING MOTEL AS APPLIED FOR PER
DEC AND TRUSTEE APPROVALS WITH FLOOD PERMIT
at premises located at
58855 CR 48
GREENPORT
County Tax Map No. 473889 Section 044
Block 0002
Lot No. 022
pursuant to application dated APRIL 3, 2006 and approved by the
Fee $
1,777.80
ignature
Building Inspector to expire on OCTOBER 13, 2007
ORIGINAL
Rev. 5/8/02
...~Jf9
[ ] FOUNDATION 1 ST
[ ] FOUNDATION 2ND
[ ] FRAMING I STRAPPING
[ ] FIREPLACE & CHIMNEY
[ ] RRE RESISTANT CONS'IlIUC'nON
REMARKS:
[ ] ROUGH PLBG.
[ ] I LATION
[ FINAL
[ ] FIRE SAFETY INSPECTION
[ ] RRE RESISTANT PENETRATION
DATE ,orA,?
I
INSPECTOR
---..-
! , :
,.f ; '~_/rf'.j ~j
TOWN OF SOUTHOLD BUILDING DEPT.
765.1802
INSPECTION
[ ] FOUNDATION 1 ST
[ ] FOUNDATION 2ND
[ ] FRAMING I STRAPPING
[ ] FIREPLACE & CHIMNEY
[ ] FIRE RESISTANT CONSTRUCTION
[ ] ROUGH PLBG.
[ ] INSULATION
[ ] FINAL
[ . 'rFIRE SAFETY INSPECTION
[ ] FIRE RESISTANT PENETRATION
REMARKS:
-_.--/
; L~,';- ~:'~,.{-t \.
'...._-,
,/ .'
DATE
INSPECTOR
" I'"
.i----'i/ft IL--
-'~-~_-~_F",~~--"'-'-F""":"'-'~~:-:-1"""-_C'~~-'~~';"-,",,,,-,,c:r.""~,,,'~~:_~~'~_~_"""'_.7' - -------:-;,.,---
-~>:-:"..--:;---~-"".-"'"
"'!;,"....
~1Jrt/i) n ~w ~,.j
TOWN OF SOUTHOlD BUilDING DEPT.
765.1802
INSPECTION
[ ] FOUNDATION 1 ST
[ ] FOUNDATION 2ND
[ ] FRAMING I STRAPPING
[ ] FIREPLACE & CHIMNEY
[ ] RAE RESISTANT CONSTRUCTION
REMARKS:
[ ] ROUGH PLBG.
[ ] INSULATION
[ ] FINAL
[iX{ FIRE SAFETY INSPECTION
r ) RAE RESISTANT PENETRAnON
~~PiL7J6YI- f~<::.<ZD
INSPECTOR ~k .
,
DATE .3/ /-D7
.
i
~
?, L '1 to g-i:;--
TOWN OF SOUTHOLD BUILDING DEPT.
765.1802
INSPECTION
[ ] FOUNDATION 1ST [ ] R~PLBG.
[ ] FOUNDATION 2ND r~SULATION
[ ] FRAMING I STRAPPING [] FINAL
[ ] FIREPLACE & CHIMNEY [] FIRE SAFETY INSPECTION
[ ] RRE RESISTANT CONSlRUCT1ON [ ] RRE RESISTANT PENETRATION
REMARKS. < n~~
~ I"11JJ'~, ~ _ 1~,
~~~ ~~ 61<T7At'2<
DATE
{
INSPECTOR /'
.
3/1of7
TOWN OF SOUTHOLD BUILDING DEPT.
765.1802
INSPECTION
[ ] FOUNDATION 1 ST [ ] ROUGH PLBG.
[ ] FOUNDATION 2ND [ ] INSULATION
[ ] FRAMING I STRAPPING [] FINAL
[ ] FIREPLACE & CHIMNEY [] FIRE SAFETY INSPECTION
[ ] RRE RESISTANT CONSTRUC'nON [ ] FIRE RESISTANT PENmATION
REMARKS'~ W-'~ ~
~ (:9r.l.g -=--J
DATE liJ.{, k;?:-
!
INSPECTOR
\~'~~"--"-----
" , ~' -'-.
3 L'io~&
TOWN OF SOUTHOLD BUILDING DEPT.
765.1802
INSPECTION
[ ] FOUNDATION 1 ST [ ] ROUGH PLBG.
[ ] FOUNDATION 2ND [ ] INSULATION
[ ] FRAMING I STRAPPING [] FINAL
[ ] FIREPLACE & CHIMNEY [] FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION
REMARKS,: ~~ C~~ ~~:u. _
~4 A7 ~ cro~. ~~-
J(~ C!i!r k ~'7.
~
DATE 11)0 lor",
/
INSPECTOR
I
- ----- -- ~- -~ ,- -~._-~- --.~- -
31 ~or-t:
TOWN OF SOUTHOLD BUILDING DEPT.
765.1802
INSPECTION
[ ] FOUNDATION 1 ST [
[ ] ~NDATION 2ND [
[f"( FRAMING I STRAPPING [
[ ] FIREPLACE & CHIMNEY [
REMARKS:
] ROUGH PLBG.
] INSULATION
] FINAL
] FIRE SAFETY INSPECTION
~~
...
DATE /y/t;0C
t
INSPECTOR
3f7fJ?&
TOWN OF SOUTHOLD BUILDING DEPT.
765.1802
INSPECTION
/
[ ] FOUNDATION 1 ST [
[ ] ~DATION 2N~[
[v(FRAMIN6RAPP1N [
[ ] FIREPLACE & CHIMNEY [
] ROUGH PLBG.
] INSULATION
] FINAL
] FIRE SAFETY INSPECTION
REMARzti;- .?~~ 10 r.::7L
11. ~ cJ6 ~ ~ 'JIf-J /9o('-c
U ":J:Jq~ ?/k(Oc'. VL ,#U- ;'~ /c-udr
'V C.q: ~---- 16....,~( ;, tZr~:" ~ 7/#/'"
/c. ' . /
HJt. ,./~ W'" 6
a_
INSPECTOR
-
3 19() f r::
TOWN OF SOUTH OLD BUILDING DEPT.
765.1802
NSPECTION
[ FOUNDATION 1 ST [
[ ] FOUNDATION 2ND [
[ ] FRAMING I STRAPPING [
[ ] FIREPLACE & CHIMNEY [
] ROUGH PLBG.
] INSULATION
] FINAL
] FIRE SAFETY INSPECTION
~
DATE 7ftf~
.
7
3\9og
J.R. Holzmacher P.E., LLC
~,'" " ",...,
. 300 Wheeler Road, Suite 303, Hauppauge, New York 11788-4300
Tel:'(cl31) 234-2220 Fax: (631) 234-2221 e-mail: info@holzmacher.com
A '[''lo . \,
\.ice.
1~
December 10, 2006
\.....
,., . '.\ .--..:-.-
\~'-'MIchael J. Verity
Chief Building Inspector
Southold Town Hall
53095 Main Road
P.O. Box 1179
Southold, New York 11971-1179
Re: Sound View Inn
Framing & Wind Load
Fasteners Certifications
Town of South old Building Inspector:
On December lOth, 2006, Mr. Michael C. Simon, PE inspected the framing and wind load
fasteners at the Sound View Inn. Photographs were taken at prior construction intervals, which
are included with this letter for your files. During the inspection, the framing and fasteners
were found to be constructed and installed satisfactorily in accordance with the plans and intent
of the latest building code.
If you have any questions, please contact us at (631) 234-2220
Very truly yours,
J.R. Holzmacher P.E., LLC
Cc: Ellen Levin Wiederlight, Sound View Inn
MCS:mcs
The Thinl Generation of Excellence
In Water Supp(v, Water Resources, Civil amI Environmental Engineeriug
.
Sound View Inn Framing Photographs Sept. 2006
Page 20f 4
;;- .. '~
~ .'
:c'
~
...~
.
-
~
I
zeJrJ~ ,')7, '0'1.\
The Third Gellemlioll (!{ Excellellce
III WI/ler SlIflfI(l'. Wtller Re.wl/rces. CiI'ill/lld Elll'irollll1ellll/l Ellgilleerillg
Sound View Inn Framing Photographs Sept. 2006
Page 30f 4
1.C!C!';;.C!;J.C!B
rite rltird Gelleratioll of Excellellce
III /VI/ter SlIpp(I" WI/ter Resollrces. Ch'ill/lIll ElIl'irolllllelltl/l Ellgilleerillg
Sound View Inn Framing Photographs Sept. 2006
Page 40f 4
The Third Gel/eratiol/ (!{ Excellel/ce
II/ Water Sl/pp~l'. Water RewurceI. Cil'il and EI/virol/mental Engil/eeril/!(
67/21/2666 15:66
~ ~ -.,
6312342221
JR HOLZMACHER PE LLC
PAGE 62
,
J.R. Holzmacher P.E., LLC
300 Wbeeler Road, Suite 303, Hauppauge, New York 11788-4300
Tel: (631) 234-2220 Fax: (631) 234-2221 e-mail: iofo@boIzmacher.com
July 20, 2006
Re: Sound View Inn
Foundation Reinforcing Steel
Town of South old Building Inspector:
On July 14th, 2006, Mr. Michael C. Simon, PE inspected the reinforcing steel for the
foundation reconstruction at the Sound View Inn. At that time, photographs were taken which
are included with this letter. During the inspection, the reinforcing steel and formwork was
found to be installed correctly. In addition to that specified on the plans, the mason added
additional bars to the CMU wall to provide additional strength. The reinforcing steel met or
exceeded that shown on the approved set of plans.
If you have any questions, please contact us at (631) 234-2220
Very truly yours,
J.R. Holzmacher P.E., LLC
Michael C. Simon, P.E.
Principal
MCS:mcs
Tile Tltird Gl!Jll'I'al;OIl of'E."cellcl/cl!
j'fI f~ilhF Supp('r. H-i.,ltdf Re,"'Ultl'ces~ CiJ,'i/ l1.lull:oltvirot111lf?l1lfll En,!fiJlE)efillg
FIELD INSPECTION REPORT
FOUNDATION (1ST)
~------------------------------------
I
FOUNDATION (2ND)
ROUGH FRAMlNG &
PLUMBlNG
lNSULATION PER N. Y.
STATE ENERGY CODE
FlNAL
'\nz
f>I."-" ,c' ,,, ~ p. ~ . u 7a (~. _'J.. .4//4. ).1_ ~ ~
I I ~"". iJ,),JL. f ~ .I. r I /l1lF.() '!L:c. #1r ~ ~
~':i{u..!J'~.-A 7J~~ nl. . tJ~ Ui. /1,.., --:.h ~~) ~
""~;.L"'- tuc.. :'..r-; J J'~lu ~. rrn...~ 0g:J
IA.. ~- . A... ~ J,~"I '?Ju },,1. . k... . b _ J' hJ ~ ~
r~~.h:-" A/F M~ /. ." ~~~. &'Ah7~ ~
I/-:'h. '1;. I, j,. . U.-unL C . ~ - . 't:. -. . "'.5
, ~ A J kt'/~-/~.\ L L~.At1 ~ I.J'J 1. -/( ~
10 / JJr,r Ani... {;~.L PI. 11 J. Lfl y/.. J 1h
A..'J "LJ'" ,/',/ .f /';..,,_,./ '," /g/}/~
/ / kn. 'J'.d. 4 r.4J,Ik,;.h 2Zf.~~ _~!. b. J'.r ~
//) 1 /. rrA:. J,,./- _ ~ U. k./ ./...... ~ &:;
/ /.nl /' (_ d'/. , L.o "L /, .~. -' ~tJ (~/ d'~ 1.'"
/ I .~~ Jf~.L. ";n/. i'1';,./ 7 .~
I. /. /11('_ I? Jj;: //.~':M- ~,. '-' ~~,~_ /
(lddJ d:. L-' ~ /;7(." /. ..1hZ- -' ~ J
I ftJlr." I'A/ -/ O~ I) L..-Pff. ~ /I, - L
('/ I ~// t- 1:I'j
'A A .t.AI C''A t/
(7'/ """'::;'-v-;u' Lu
// . cfY" u:/-.
V ~#../ I ~ ~ 7
.7 ,.
DATE
7/Y$') ~~ 4.. ,a"
I / ~
COMMENTS
In ( , ~/
..,/-'M..-z I
'l 1
A
.;I.
r;;;Lol'..r. .. ~ ) ~ /n
"/I /
r
.. ,\
....
"'. ,
:?':
,:/
"]
. ADDITIONAL COMMENTS
IJoc (i\fn.. ^) oLul.. ~ /" JiJo rPo... ._
_,' , I V
1'12.~ i. J1'0'" 1I.11.,.J,. . \ / ,
I ~}.-,<I:? 1 ~~ 'vi
-L
. .
"
/7 I l .
v-Ult
,
\Zk,l)/.? tl17fi '0JA. '.Ii dI_ /I...
,
g/i 107 hrz.t "
"
.n;;--. 1~l
-of-
t'
J'\ V~80 _ .f'- r LUL-
I
')
~
-'"
-o~
c~
~~
~
~~
~
~
< ,
1~
.(1!B'
J
-~
0;><:
-'"
- ...
~!;:
--..,
""...
--30
z
\~
I'l
."
;'l
DEC-8-2006 0:;: 49,' FRDM: 8E~;TQUALITYWATER
b312981 c_, '::
TD:7659502
P.2
Best Quality Watn' Corp. I Tara Plumbing Corp.
3:~(l:) Ole Jute Law'
P.O. Box 17,5
Mattituck, N.Y. 11952
Tele~hone: (631) 298 - 3894
Fax: (631) 298 ,0. E20
MP- iM'1
December 8, 2006
S/)'kthold Tovvn Building Depz.
:;4};S Main Road
Soutlwld, N.Y. ] 1971
Attn: lr.spectoJ Gary Fish
As per the" illumbing inspection (.4 .l;.:, Soundvlew Motel Permit if.
)\51: S l on Dt'l~ember~, 20(\6 the tire cauly,ing to all PVC, sanitary, VI:" and
pl",'ab .~ 'Vf~r has been insta1\:d on Del.emher 6,2006.
f',ease sig'1 off for the .,dlding to b'~ insu1r.ted. Pleall; fax to (631) :t98
-;'910.
Sinc~;'ely,
11. -' .-.-.....
,-L.---------- "
Wilh m Gren\ ~
C.C
Frl'[.~ UiFede p,,'j".:l MUBgI'
fil.e:1 \l;~iderligh: '.' vrCi
\-.::----=---;:-- -
1,...\ '
I.
.-.~_.---:--l
, r',,"\i
Albert J. Krupski, President) 2 2 2005
James King, ViJe-Prt.e;!d.ent
Artie Forter . \ i !
Ken PoliWoda'-
Peggy A. Dickerson
Town Hall
53095 Route 25
P.O. Box 1179
Southold, New York 11971-0959
Telephone (631) 765-1892
Fax (631) 765-6641
BOARD OF TOWN TRUSTEES
TOWN OF SOUTHOLD
Permit No.: 6196A
Date of Receipt of Application: 9/7105
Applicant: Ellen Levin Wiederlight
SCTM#: 44.2.22
Project Location: 58775 Route 48, Greenport
Date of Resolution/Issuance: September 21, 2005
Date of Expiration: September 21,2007
Reviewed by: Board of Trustees
Project Description: Rebuild existing portion of central building with addition of
an 80' x 18' second-story, and rebuild the existing deck, and the proposed
construction will be on the existing foundation, with drainage to contain roof
runoff, and all as depicted on the plan prepared by J.R. Holzmacher P.E., LLC
and last revised 9/16/05.
Findings: The project meets all the requirements for issuance of an
Administrative Permit set forth in Chapter 97 of the South old Town Code. The
issuance of the Administrative Permit allows for the operations as indicated in the
project description.
Special Conditions: Final Inspection at completion of project.
If the proposed activities do not meet the requirements for issuance of an
Administrative Permit set forth in Chapter 97 of the South old Town Code, a
Wetland Permit will be required.
This is not a determination from any other agency.
~.-f 9. ~'(}.
Albert J. Krupski, Jr., President
Board of Trustees
- ---.--:::>
- 'i!' r":i I
.. '. -. r I
,i!
:r-- ~
" r \
,I! ,'.
if .
Albert J. Krupski, Pre~i~ 2005
James King,. Vice-Presid~~
Artie Fqster
Ken Poliwoda
Peggy A; Dickerson
,
Town Hall
53095 Route 25
P.O. Box 1179
Southold, New York 11971-0959
Telephone (631) 765-1892
Fax (631) 765-6641
BOARD OF TOWN TRUSTEES
TOWN OF SOUTHOLD
COASTAL EROSION MANAGEMENT PERMIT
Permit #6196
Date: September 21,2005
SCTM# 44-2-22
Name of Applicant/Agent: J.R. Holzmacher P.E., LLC
Name of Permittee: Ellen Levin Wiederlight
Address of Permittee: P.O. Box 68, Greenport, NY 11944
Property Located: 58775 Route 48, Greenport
DESCRIPTION OF ACTIVITY: Rebuild existing portion of central building, with addition
of an 80' x 18' second-story, and rebuild the existing deck; the proposed construction
will be on the existing foundation, with drainage to contain roof runoff, and all as
depicted on the plan prepared by J.R. Holzmacher P.E., LLC and last revised 9/16/05.
Permit to construct and complete project will expire two years from the date the permit
is signed.
SPECIAL CONDITIONS: (apply if marked)
_ Bluff restoration through a re-vegetation plan is a necessary special condition of this permit.
_ A relocation agreement is attached hereto and is a necessary special condition of this permit.
_ A maintenance agreement is attached with application and is a necessary special condition of
this permit.
Albert J. Krupski, Jr.
President, Board of Trustees
AJKlhkc
~9~.~'~.
83/15/2885 12:28 5312342221 JR HOLZMACHER PE LLC
NYSDEC OOIRDN PERMITS Fax:631tW1036O Mar 16 2006 13:10
PAGE 82
P.02
NEW YORK ST"TE DEPARTMENT OF ENVIRONM8IrTALCONSERV"TI0N
DEG PERMIT NUMBER
1-4738-00437I00007
FACILITVIPROORAM NUMSER(S)
.
PERMIT
IJnder the EnvironllMll!al
Coneervllllon LlIw
EFFECTIvE DATI;
March 16. 2006
EXPIRATION OATE(S)
MarcI1111,2011
TYPE OF PERMIT. New 0 ReneWS! [J Modification 0 Pe/It1IIfQ ConstruCt 0 Permit to Operala
o Article 15. Tille 5: Protection orWeters
o Jl\rtJCIe 17. llnes 7, 8: SPDES
o Article 27. Tille 9; 6NYCAA 373:
Hazardous Waste Manag_
o Article 34: Coastal Erosion
Mll11agement
o Article 3& Floodp/<lln Management
o Articles I, 3,17,19. 27,37; 6NYCRR
380: Radiation Control
1:1 Artlcte 15, TIU" 16: Water Supply
o Article 15, nUe 15: Water Tranepolt
o Article 15, TItle 15: Long Island Well.
o ArtIoIe 1110 Air Pollution COntrol
o ArtiCle 23. Tille 27: Mined l3nd
Reclama1ion
o Artide 24: F(llO/1wlIler WelIands
o Article 16. Tille 27: Wild, Scenic and
RecrealionalRlv\!r.l
. ArticIa 25: 'I1daI Wenands
o 6NYCRR 808: Water Quality Cer1lf....
o Ar1lCIe 27. Tille 7; 6NYCl'll'l360:
lion Solid Waste Manma"mel1l
PERMIT ISSUED TO TeELEPHONE NUMBER
Ell.." Levin Wlederliaht 631\477-1910
ADDRESS OF PERMITTEE
PO Box 68. .NY 11944
CONTACT PERSON FOR PERMITTED WORK TELEPHONE NUMflER
J.R. Holzmacher, LlC. 300 Wheeler Road. Ha NY 11788 1631\ 234-2220
NAME AND ADDRESS OF PROJECTIFACILITY
Sound VieN Inn Motel. North Roell I3reenoort
COUNTY I TOWN I WATERCOURSE NYTM COORDINA TE;S
Suffolk Southald lona Istend Sound E: N:
DESCRIPTION OF AUTHORIZED ACTIVITY: ReCOll$1ruct a on8 s10ry motel building damaged by fire.
NI work is to be done in accordance with the attac/1Qd plans stamped NYSDEC approv9d on 3/1612006.
By acceptance of !his permit, the permittee agrees that the permit is contingent upon striel compliance with the
Eel. all applicable regulations. the General Conditions specified and any Spe<<ial Conditions included as part of !his
mil.
DEPlITY PERMIT ADMINISTRATOR
Mark Catrara
AUTHORIZED SIGNATURE
March 16. 201;)6
Pa 8 1 of 4
,20L
BUILDING PERMIT APPLICATION CHECKLIST
Do you have or need the following, before applying?
Board of Health
4 sets of Building Plans
Planning Board approval
Survey
Check
Septic Form
N.Y.S.D.E.C.
Trustees
Contact:
Mail to: ;;: I?- HOLZMI/t/l6"R. r;t;
~.Ip~~~'ii:f7F 303
Poooo: h3/-234-zZ?D
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
TOWN HALL
SOUTHOLD, NY 11971
TEL: (631) 765-1802
FAX: (631) 765-9502
www.northfork.net/Southoldl
PERMIT NO. "3110~C
Expiration
Examined
20 h
,20k-
Approved
Disapproved ale
Sl(f7b <i -- L( 2- &-<(;
MAR 20
APPLICATION FOR BUILDING PERMIT
. ,
",
Date
/fuo/vd'r :s/ ,20 oS;
INSTRUCTIONS
a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4
sets of plans, accurate plot plan to scale. Fee according to schedule.
b. Plot plan showing location oflot and of buildings on premises, relationship to adjoining premises or public streets or
areas, and waterways.
c. The work covered by this application may not be commenced before issuance of Building Permit.
d. Upon approval of this application, the Building Inspector will issue a Building Permit to the applicant. Such a permit
shall be kept on the premises available for inspection throughout the work.
e. No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector
issues a Certificate of Occupancy.
f. Every building pennit shall expire if the work authorized has not commenced within 12 months after the date of
issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the
property have been enacted in the interim, the Building Inspector may authorize, in writing, the extension of the permit for an
addition six months. Thereafter, a new pennit shall be required.
APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Pennit pursuant to the
Building Zone Ordinance of the Town of South old, Suffolk County, New York, and other applicable Laws, Ordinances or
Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The
applicant agrees to comply with all applicable laws, ordinances, building code, housing code, and regulations, and to admit
authorized inspectors on premises and in building for necessary inspections.
SJhV) f/;-v kv.A/ L
(Signature of applicant or name, if a corporation)
fo. b! t:-er'''''d~..A/f /1.97ff
(Mliling Bress of applicant)
State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder
cJwll.,r
€LLt=Ai
Name of owner of premises L.EVIAI W(cj)~Au(;lrr
(As on the tax roll or latest deed)
If applicant is a corporation, si ature of duly authorized officer
'-L/?A/ LEV/V I E'b~L/ IIr
(Name and title of c rporate officer)
Builders License No.
Plumbers License No.
Electricians License No.
Other Trade's License No.
House Number
Street
G,eE.E#POR-r
Hamlet
I. Location of land on which proposed work
County Tax Map No. 1000 Section
Subdivision
#
Block 2-
Filed Map No.
Lot
Lot
22-
(Name)
2. State existing use and occupancy of premises and intended use and occupancy of proposed construction:
a. Existing use and occupancy R- I. M((J 17="L - ;;;;eAA/JIE-vr
~
b. Intended use and occupancy
34M.G
3. Nature of work ~eck which applicable): New Building
Repair V Removal Demolition_
4. Estimated Cost ~ ;; ZOO, C) 0 O. .- ~ S"M. ooD. Fee
, ,
Addition
Other Work
/'
Alteration
(Description)
5. If dwelling, number of dwelling units
If garage, number of cars
(To be paid on filing this application)
Number of dwelling units on each floor
M Or~L - G-ueJ'r ,e,t(f.
6 Ifb . 'al' d 'fy d f h f L 0887'. c oIVFC'~&
. usmess, commerCl ormlXe occupancy, specl nature an extent 0 eac type 0 use. ItUOAJ<.':(l'T Af'JnAA
7. Dimensions of existing structures, if any: Front 5" S ~ I
Height /2.." Number of Stories p".~, .'.4-<-
Rear t;;; S' 5" / Depth / &',c. I
SIPr;.LS' 'To / c!l,r CPv .~..,.L.A-.....C71
;Peb'8~
Dimensions of same structure with alterations or additions: Front t;;; ~ 5'; Rear s s: S' /
Depth / fl. (", / Height ~O / Number of Stories 2-, ?o'i!J,I=" Cetff,uL.
-
A-t"'C",4 .
I fl. , /
9. Size oflot: Front
8. Dimensions of entire new construction: Front ~ <::"5" /
Height 50 / Number of Stories
Roo /
/95o,j
Rear
5"55/
Depth
2..
Rear
~ E30/
Depth
75' 1f)
23D1
10. Date of Purchase
Name of Former Owner
II. Zone or use district in which premises are situated
12. Does proposed construction violate any zoning law, ordinance or regulation? YES_NO /
B. Will lot be re-graded? YES_ NO / Will excess fill be removed from premises? YES_ NO ./
PO l30x b~ r;;12E13A/{>O,€.r
~ddressAl.Y. )1"(1..4 Phone No. r;,31-477~(1110
Address l:M'i.,x,,1if:t?lJt!-lJft Phone No?~ 1- 234--77"? 0
Name of Contractor Address Phone No.
15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES / NO_
* IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMIT~ MAY BE REQUIRED.
b. Is this property within 300 feet of a tidal wetland? * YES ~ NO_
* IF YES, D.E.C. PERMITS MAY BE REQUIRED.
16. Provide survey, to scale, with accurate foundation plan and distances to property lines.
17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey.
STATE OF NEW YORK)
SS:
COUNTY OF )
being duly sworn, deposes and says that (s)he is the applicant
g contract) above named,
(S)He is the
~ilVNE..tl
(Contractor, Agent, Corporate Officer, etc.)
of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;
that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be
performed in the manner set forth in the application filed therewith.
lJ\ ~ore me this .I{
day of f....
2Qr~
Notary
SUSANN IGIT
Notary Public, State Of New York
No.30.4625605
Qualified In Nassau County,1. ~ /
Commission Expires June 30~b
~~LY-
Signature of pplicant
:.".... .
,I
rllwn Hall. 5.10\15 Matt,
P.O, nil, IIH
Slluthold. New.Yurk .
F" IS I(d 7"''<'IR~
Telerhone (S 1(11 7(,$':
.i ..~. .'
. . 'J'tIP'lTH T. TERRY
e toWl'l CLERK
rU::::CISTF1Nl or VlTt\.L ST^11S11CS
M^F1nIAGF. orFlcl':f1
RECORIJS MM^GEMENT olTICEIl
rREEDOM OF INFOfUMTION OFFICER
OFFICE OF THE TOWN CLERIC
TOWN OF SOUTH OLD
THIS IS TO CERTIFY THAT THE FOLLOWING RESOLUTION WAS ADOPTED BY THE
SOUTHOLD TOWN BOARD AT A REGULAR MEETING HELD ON AUGUST 14, 1993:
RESOLVED that the Town Board of the Town of Southold hereby adopts
two (1) new forms to be used under ttie Flood Damage Prevent regulations .J
OJ the Code of the Town of Southold:
f'pplication" (FDP(93)!. and ':'Certificate
j
Special Flood Hazard Area [CIC(93l].
"Floodplain
De:velopment Pe rmi t
i ';
7"r Deve.~l'pmen t in
of Campi ia nee
fO\L5: I,Go I~~-
~~ :
8wu. Oc.rT .~-
TO,^;~ OF SOlJTliOLD
l
.'
i i~1
.'
~.
"///.4:~~
~hT.T~
Southold Town Clerk
August 25, 1993
. "
"
"
5~.. .
..
APPLICATION iI
PNjE I O( 4
TOWN OF SOUTHOLO
fLOODPLAIN DEVELOPMENT PERMIT APPLICATION
This Corm is to be filled out in duplicate.
,
SECTION I: GENERAL PROVlSIONS (APPLICANT 10 read and liom ):
L No work may start until a permil is issued.
2. The permit may be revoked if any falle statements are made herein.
3. If revoked, all work must cease unt~ permit is re-issued.
4. Development shall Dot be lLSed or occupied UDt~ a CertifiC1lte of Compliance is issued.
5. The permit will expire if "0 work is commenced within six months of issuance.
6. Applicant is hereby informed that other permit; may be required to fulfilllocaJ, state and federal regulatory
requirements,
7, Applicant hereby gives consent 10 tbe Local Administrator or his/her representalive to make reasonable
, inspections required to verify compliance. .
8. r. THE APPLICANT, CERTIFY THAT ALL STATEMENTS HEREIN AND IN A TTACHME]ITS TO
_ THIS APPLICATION ARE. TO THE BEST OF MY KNOWLEDGE, TRUE AND ACCURATE.
(APPLICANT'S SIGNATURE)~~ DATE d7kh
) I
, / /
//SECTfON 2: PROPOSED DEYELDer.hENT lTo. (,e comDIe'ed bv APPLlCAlfl1
.
NAME ADDRESS
APPLICANT C' J '
JO/)/",v' /J/~.-v J"v"/
BUILDER...-r ~ 11 -1 . "vi
'7.0 ~ J/eTt'r'" (r-'~
ENGINEER JJ../ /
II h 4?lKh~r
TELEPHONE
t-JI-Cl}7-/'f/O
PROJECT LOCATION:
To avoid delay io processing the .ppUGltion, please provide eDough Wormatioo to easily identify tbe project
locatiolL Provide the street address, lot number or legal description (attach) and. outside urban areas, the
dLs(aocc to the nearest intc..rsccting road or wcU-laOWD lindmark. A sketch atlachcd lo lhi..s application sbowing
the project location would be helpful.
~ Repl1il' ({ 1!epJl/'cG- &,vYZO/ ~tl /LJ),7
Lff Cr~"'f,r1; /vr 11"7/
tf) $~77r fbt
FDP(9J)
".
'.' .
\ (. ~
.'
1'..,
',' ,
,
APPUCA liON ;'!
PAGE10Fd
DESCRIPTION OF WORK (Check all appuGlbk boxes)
A ,TRUCTURAL DEVELOPMENT
ACTIVITY
STRUCTURE TYPE
o New Structure
o Adclitioo
o Alteration
o RoIocal;oo
o DemoUtioD
l!I"Replaccmeot
o ResideotiaJ (1-4 Family)
o Residcotial (More thaJJ 4 Fwaily)
o Noo-resideotial (F1oodprooflDg? 0 Yes)
o Combined Use (Rosideotial &. ComroercW)
p 0 Manufactured (Mobile) Home (10 MaJJu,
f.elured Home Parkl 0 Yes)
ESTIMATED COST OF PROJECT S
B, OTHER DEVELOPMENT AcnVlTIES:
o Fill 0 Mining 0 Drilling 0 Grading
o Excavation (Except for Structural Development Cbecked Above)
o Walercourse Alteralion (Including Dr<<lging aod Channel Modifications)
o Drainage Improvements (Including Culvert Work)
") 0 Ro,;), Street or Bridge ConstnJction
/ 0 SuykuvisioD (New or Expausioo)
/ 0 ~dua1 Water or Sewer System
o Otber (PI=-se Specify)
.
/
/
,
/
After completing SECTION 2, APPUCA.l'IT shouJd submit form to Local Adminislrator [or review.
SECTION}; FLOODPLACN DETERMINA.TION eTa be cO!TIokled bv LOCAL ADM[/'flSTRATOR)
The proposed developmellt is located Oll FIRM Panel No.
Dated
The Proposed Development:
o u lli2I locale<! in a Special Flao<! Hazard Area (Notify the 'ppUcant that the application
review is complete and NO FLOODPLAIN DEVELOPMENT PERMIT [S REQUIRED),
o Is located io , Sped.1 F1ao<! Haurd Ana.
FIRM wne de.c;ig:nation ls
100- Year nao<! elcv,tioo ,t the sile is; Ft. NOVO (MSL)
cJUaavaiJ,blc
o The proposed developmenl is localed 10 ;} Ooodway.
FE FM Panel No. D'led
o See Section lj (or ,Hlrlilional iQslrl)((ioo.\
SICi'lED
DATE
".
','
$. .
',' ,
"
.
APPLICATION .,tI
PAGEJOF4
-
SECTION 4: ADDITIONAL INFORMATION REQUIRED (To he comnkted bv LQCAL ADMINISTRATOR)
The applicant must submit the documents checked below belere tbe appliQuon can be processed:
o A site plan showing tile location or all existing structures, w-a,ter bodies, adj!lccot roads, IOl
dimeDsioD5 and proposed development.
o Development plans, drawn to SQIe, and spccificati;Jns, includiDg wbere applicable; details ror
ancboring structures, proposed elevation of In west Ooor (including bastmeot), types of water
resistant materials used below tbe flfst Ooor, details of OoodprooflIlg of utilities located below
the flfst Ooor and dct:tils of cnclosllfes below tbe first Ooor.
Also.
o Subdivision or nther development plans (I! tbe subdivision or otber development exceeds 50
lots ar 5 acres, wbichever is tbe lesser, the appUcant !!Illil provide lOO-year aood elevatians
if they are Dot otberwise available).
o Pla.Q.S showing tbe extent of watercourse relocatioD and/or landform alterations..
o Tnp of DeW nu elevation
Fl. NOVO (MSL).
o Floodproofmg protection level (noD-residential ooly) Fl.' NOVO (MSL). For
Ooodproofed structures, "ppUcant must attacb certification from r~gistered engineer or
_ architect.' / /.
o Certification [rom a~r;gis(ercd engineer tbat the proposed adi<.!il in a regulatory fioodway
will oot result in .@Y increase in the beight oC Lhe lOO-ycar naod. A copy of ill data and
caJcu1ations supporting this rUlding must aJso be submitted.
o Otber.
SECTION 5: PERMIT DETI:RMINATION [To be romDlcted bv LO<':A.L ADMINISTRATOR)
I bave determined tbat tbe proposed activity: A. 0 Is
B.O Is not
in conformance with prnvisiolU of Local Law # . 19 The permit is issued subject to tbe coodillons
attached lo and made part or tbls ~rmit. ~-
SIGNED
. DATE
If BOX A is cheCKed, Ibe LouJ Admioislralor may is,"c a Dcvclopmeol Perm;1 upon paymcnl of designatcd
fce.
If ~OX B is chcck~d, tbe Local Administrator wiJl provide a written summary o( dcndencic..s. Applicant may
reVlSC and resubmIt il11 application to the Local Administrator or may request a bcarLng (rom tbe Board of
AppcoJs
~ , "
".
.... "
.' APrLlCA TION #
PAGE 4 OF 4
APPEALS Appealed to Board of Appeals? 0 Yel 0 No
HeaIwg dale:
Appeals BUill d D(..,-~;vu --- Appl uy(..d? 0 Y (.J 0 pie
COodilion5
SECTION 6: AS.DUlLT ELEVATIONS ITo be submilled bv APPLICANT belore CertiJicate of Comoliance
is issued)
The foUowiog information must be provided for project structures. This section must be completed b:y a
registered professioD,a1 eDgineer or a liccDSed land ,urvcyor (or attach a ccrtlficauon 10 this application).
Complete I or 2 below.
I. Actual (As-Built) Elevation of the lOp of the lowest Door, including basemeDt (in Coastal Hi2h HaUl'rd
Areas. bottom of lowest structural member of the lowest Door, excludlng piling and columns) is:
FT. NGVO (MSL).
L . " Actual (As.Bu~t) Elevation of noodprooHng prolectioa is FT. NOVO (MSL).
/ '; .) '".i
N7: Any work performed prior to submittal/of the above inIormatioa is a( Ibe ris~;;'f the Ap~;:cant.
...1 /' .,'
SECTION 7: COMPLIANCE ACllON 1T0 be com Dieted bv LOCAL ADMINISTRATOR)
The LOCAL ADMINISTRATOR will completc lhis scction as applicable ba.scd 00 inspectioo of the project to
ensure compliance wlth the community's loea! law for Oood damage prevention.
INSPECllONS: DATE
DATE
DATE
BY
BY
BY
DEFIClENOES? 0 YES 0 NO
DEFICIENCIES? 0 YES 0 NO
DEFIClENOES? 0 YES 0 NO
SECTION 8: CERTIFICATE OF COMPLlANCElTo be eomnleled bv LOCAL ADMll'IISTRATOR)
Certlfic.ale 01 Compliance muod: DATE:
BY:
- "
'" .
" ,
'. .,
"
"
Jl.ttadutlent B
/
j
/ 8AH~;-LE
CERT1Y1CJl.TEj.JF COKPLIANCE
for Developm~nt in a special Flood Hazard Area
-.
"
lit.. .
I, I
"". If
I ~",. .
..
.'
'. ,
TOWN OF SOUTHOLD
CERTIFICATE OF COMPLiANCE
FOR DEVELOPMENT [N A SPECIAL FLOOD HA2AJill AREA
(OWNIW MTlST REH TN TIllS <.ERTIFICATE)
PREMISES LOCATED AT:
5"37/) PI IIfJ
tlro!....... pHil fi/Y
PERMIT NO,
PERMIT DATE
flv71
.
OWNERS NAME AND. ADqRES,S:
1J~!iJ;I;!l1{~4i
J
CHECK ONE:
o NEW BUILDING
~STING BUrLDING
o VACANT LAND
!
,
I
/)
TIlE LOCAL ADMINISTRATOR IS TO COMPLETE ^' OR B. BELOW:
A. COMPLIANCE IS HEREBY CERTIfIED WITH THE REQUIREMENTS OF
LOCAL LAW # _, 19
SIGNED: DATED:
B COMPLIANCE IS HEREBY CERTIFIED WITH TIlE REQUIREMENTS OF
LOCAL LAW # ,19_, AS MODIFIED BY VARJANCE #
DATED
SIGNED: DATED:
C I C (93)
SVI calcs.xls/Roof Drains
Stormwater Component Sizing
SoundView Inn
Greenport, New York
Existing Motel Dimensions
Stormwater Leaching System Component Sizing
Svlnn 05-01
::::::::::::::
I
Narative: Town of Southold requires that no roof runoff be discharged directly to the Long Island Sound.
Gutters and leaders will be routed to drywells on the land side of the building
Design Storm Event 2.0 Inches = 0.167 Feet
(Assume no leaching during storm event.)
Assume flat roof portion drains toward the LI Sound side.
Paved Rainfall design
(sq feet) (feet) Runoff factor Storm Water Volume
(cubic feet) (gallons)
Roof Area (west) 2,314 0.167 0.95 366 2,741
Roof Area (center) 1,500 0.167 0.85 213 1,590
Roof Area (east) 4,344 0.167 0.6 434 3,249
Foundation Drains Q
1013 7,580
Dia. of Leaching pool depth of total (cubic
Leaching pool wall thickness pool (It) feet) (gallons)
Storm water units 10 0.333 4.0 293 2,195
Minimum stormwater rings required:
Storm Water Volume (cubic feet)
1013
293 3.5 rings
13.8131 feet ofsldewall
Use:
4 shallow poois w/1 ring and slab each
..10....-
1 of 1
9/16/2005
Permit #
Permit Date
COMcheck Software Version 3.2.0
Envelope Compliance Certificate
New York State Energy Conservation Construction Code
Report Date: 03/31/06
Data filename: P:\2005\SVlnn\05-01 Reconstruction\Design\EnergyCalcs 03 31 06.cck
Section 1: Project Information
Project Title: Sound View Inn Reconstruction of Motel
Construction Site:
North road
Greenport, NY 11944
Owner/Agent:
J Robert Holzmacher
J. R. Holzmacher P .E., LLC as agent
300 Wheeler Road, Suite 303
Hauppauge, NY 11788
(631) 234-2220
info@holzmacher.com
Designer/Contractor:
J Robert Holzmacher
J. R. Holzmacher P.E., LLC as
Engineer
Section 2: General Information
Building Location (for weather data):
Climate Zone:
Heating Degree Days (base 65 degrees F):
Cooling Degree Days (base 65 degrees F):
Project Type:
Vertical Glazing / Wall Area Pct.:
Suffolk, New York
11b
5750
715
Addition
11%
Actlvltv TVDe(s\
Hotel/Motel Guest Room
Lobby. Hotel
Floor Area
9600
363
Section 3: Requirements Checklist
Envelope TaD Invalid SHGC(s)
Climate-Specific Requirements:
Component Name/Description Gross Area Cavity Cont. Proposed Budget
or R-Value R-Value U-Factor U-Factor
Perimeter
Roof 1: AII.Wood JoistlRafterfTruss 4200 0.0 30.0 0.032 0.059
Exterior Wall 1 : Wood Frame, Any Spacing 2450 15.4 0.0 0.060 0.090
Window 1: Wood Frame:Triple Pane, Clear, SHGC 0.00 400 0.500 0.598
Door 1: Solid 252 0.500 0.142
Interior Wall 1 : Wood Frame, Any Spacing 1300 8.0 0.0 0.112 0.142
Basement Wall 1 : Solid Concrete or Masonry> 8", Furring: None, 2140 8.0 0.103 0.113
Wall HI 7.5, Depth B.G. 3.0
Floor 1: All-Wood JoistlTruss 2750 0.0 0.0 0.282 0.055
(a) Budget U.factors are used for software baseline calculations ONLY, and are not code requirements.
Air Leakage, Component Certification, and Vapor Retarder Requirements:
o 1. All joints and penetrations are caulked, gasketed, weather.stripped, or otherwise sealed.
Sound View Inn Reconstruction of Motel
Page 1 of9
o 2. Windows, doors, and skylights certified as meeting leakage requirements.
o 3. Component R-values & U.factors labeled as certified.
o 4. Insulation installed according to manufacturer's instructions. in substantial contact with the surface being insulated, and in a
manner that achieves the rated R-value without compressing the insulation.
o 5. Fireplaces installed with tight fitting non-combustible fireplace doors.
o 6. Stair, elevator shaft vents, and other dampers integral to the building envelope are equipped with motorized dampers.
o 7. Cargo doors and loading dock doors are weather sealed.
o 8. Recessed lighting fixtures are: (i) Type IC rated and sealed or gasketed; or (ii) installed inside an appropriate air-tight
assembly with a 0.5 inch clearance from combustible materials and with 3 inches clearance from insulation material.
o 9. Vapor retarder installed.
Project Notes:
Owner contact information,
Ellen Levin Weiderlight
Page 2 of 9
Sound View Inn Reconstruction of Motel
Permit #
Permit Date
COMcheck Software Version 3.2.0
Lighting and Power Compliance
Certificate
New York State Energy Conservation Construction Code
Report Date: 03/31/06
Data filename: P:\2005\SVlnn\05-01 Reconstruction\Design\EnergyCalcs 03 31 06.cck
Section 1: Project Information
Project Title: Sound View Inn Reconstruction of Motel
Construction Site:
North road
Greenport, NY 11944
Owner/Agent:
J Robert Holzmacher
J. R. Holzmacher P.E.. LLC as agent
300 Wheeler Road, Suite 303
Hauppauge, NY 11788
. (631) 234-2220
info@holzmacher.com
Designer/Contractor:
J Robert Holzmacher
J. R. Holzmacher P.E., LLC as
Engineer
Section 2: General Information
Building Use Description by:
Project Type:
Activity Type
Addition
Actlvltv TVDe(s\
Hotel/Motel Guest Room
Lobby - Hotel
Floor Area
9600
363
Section 3: Requirements Checklist
Interior Lighting:
o 1. Total actual watts must be less than or equal to total allowed watts.
Allowed Watts Actual Watts Complies
690 640 YES
o 2. Exit signs 5 Watts or less per side.
Exterior Lighting:
o 3. Efficacy greater than 45Iumens/W.
Exceptions:
Specialized lighting highlighting features of historic buildings; signage; safety or security lighting; low-voltage landscape
lighting.
Controls, Switching, and Wiring:
o 4. Independent controls for each space (switch/occupancy sensor).
Exceptions:
Areas designated as security or emergency areas that must be continuously illuminated.
Lighting in stairways or corridors that are elements of the means of egress.
o 5. Master switch at entry to hotel/motel guest room.
o 6. Individual dwelling units separately metered.
o 7. Each space provided with a manual control to provide uniform light reduction capability.
Page 3 of 9
Sound View Inn Reconstruction of Motel
Exceptions:
Only one lumlnalre in space;
An occupant-sensing device controls the area;
The area is a corridor, storeroom, restroom, public lobby or guest room;
Areas greater than 250 sq.ft.
D 8. Automatic lighting shutoff control in spaces greater than 250 sq.ft in buildings larger than 5,000 sq.ft.
o 9. PhotocelVastronomical time switch on exterior lights.
Exceptions:
Lighting intended for 24 hour use.
D 10. Tandem wired one-lamp and three-lamp ballasted luminaires (No single.lamp ballasts).
Exceptions:
Electronic high-frequency ballasts; Luminaires not on same switch.
o 11. Transformers meet minimum efficiencies listed in Table 805.6.1 or 805.6.2.
Section 4: Compliance Statement
Compliance Statement: The proposed lighting design represented in this document is consistent with the building plans,
specifications and other calculations submitted with this permit application. The proposed lighting system has been designed to
meet the New York State Energy Conservation Construction Code requlrem ts in COMcheck Version 3.2.0 and to comply with the
mandatory requirements In the Requirements Checkli
:JlMp IZ - lha--4~
Principal Lighting Designer-Name
'/ ~/M'
Date
Sound View Inn Reconstruction of Motel
Page4of9
Permlt#
Permit Date
COMcheck Software Version 3.2.0
Lighting Application Worksheet
New York State Energy Conservation Construction Code
Report Date:
Data filename: P:\2005\SVlnn\05-01 Reconstruction\Design\EnergyCalcs 03 31 06.cck
Section 1: Allowed Lighting Power Calculation
A
Area Category
B
Floor Area
(ft2)
9600
363
C
Allowed
Watts I ft:2
N/A
1.9
Total Allowed Watts =
D
Allowed Watts
(BxC)
N/A
690
690
Hotel/Motel Guest Room
Lobby - Hotel
Section 2: Actual Lighting Power Calculation
A
Fixture ID : Description I Lamp I Wattage Per Lamp I Ballast
B C D E
Lamps! #01 Fixture (CXD)
Fixture Fixtures Watt.
1 40 16 640
Total Actual Watts = 640
Compact Fluorescent 1: Other / Electronic
Section 3: Compliance Calculation
If the Total Allowed Watts minus the Total Actual Watts is greater than or equal to zero, the building complies.
Total Allowed Watts =
Total Actual Watts =
Project Compliance =
690
640
50
lighting PASSES DeSign 7% better than code
Sound View Inn Reconstruction of Motel
Page 5 of 9
Permit #
Permit Date
COMcheck Software Version 3.2.0
Mechanical Compliance Certificate
New York State Energy Conservation Construction Code
Report Date: 03/31/06
Data filename: P:\2005\SVlnn\05-01 Reconstruction\Design\EnergyCalcs 03 31 06.cck
Section 1: Project Information
Project Title: Sound View Inn Reconstruction of Motel
Construction Site:
North road
Greenport, NY 11944
Owner/Agent:
J Robert Holzmacher
J. R. Holzmacher P.E., LLC as agent
300 Wheeler Road. Suite 303
Hauppauge, NY 11788
(631) 234-2220
info@holzmacher.com
Designer/Contractor:
J Robert Holzmacher
J. R. Holzmacher P.E., LLC as
Engineer
Section 2: General Information
Building Location (for weather data):
Climate Zone:
Heating Degree Days (base 65 degrees F):
Cooling Degree Days (base 65 degrees F):
Project Type:
Suffolk, New York
11b
5750
715
Addition
Section 3: Mechanical Systems List
Quantity System TVDe & Descrlotlon
1 HVAC System 1: Heating: Hydronic or Steam Coil, Hot Water / Cooling: Other, Capacity >=90 - <135 kBtu/h,
Evaporatively Cooled Condenser / Multiple-Zone
2 Water Heating 1: Service Water Heater w/ Circulation Pump
Section 4: Requirements Checklist
Requirements Specific To: HVAC System 1 :
o 1. Minimum one temperature control device per zone
o 2. Balancing and pressure test connections on all hydronic terminal devices
o 3. Integrated air economizer required
Exception: Minimum cooling equipment efficiency: 11.4 EER
o 4. Systems serving more than one zone must be VAV systems
o 5. Controls capable of resetting supply air temp (SAT) by 25% of SAT-room temp difference
Requirements Specific To: Water Heating 1 :
o 1. 1-in. pipe insulation on circulation systems
o 2. Automatic on/off control required for circulating systems
Generic Requirements: Must be met by all systems to which the requirement is applicable:
o 1. Load calculations per 2001 ASHRAE Fundamentals
o 2. Plant equipment and system capacity no greater than needed to meet loads
Sound View Inn Reconstruction of Motel
Page 6 of 9
03.
04.
05.
06.
Exception: Standby equipment automatically off when primary system is operating
Exception: Multiple units controlled to sequence operation as a function of load
Minimum one temperature control device per system
Minimum one humidity control device per installed humidification/dehumidification system
Thermostatic controls has 5 degrees F deadband
Exception: Thermostats requiring manual changeover between heating and cooling
Automatic Controls: Setback to 55 degrees F (heat) and 85 degrees F (cool); 7-day clock, 2-hour occupant override, 10-hour
backup
Exception: Continuously operating zones
Exception: 2 kW demand or less, submit calculations
Automatic shut-off dampers on exhaust systems and supply systems with airflow >3,000 cfm
Outside~air source for ventilation; system capable of reducing OSA to required minimum
R-5 supply and return air duct insulation in unconditioned spaces R.8 supply and return air duct insulation outside the
building R~8 insulation between ducts and the building exterior when ducts are part of a building assembly
Exception: Ducts located within equipment
Exception: Ducts with interior and exterior temperature difference not exceeding 15 degrees F.
Ducts sealed -longitudinal seams on rigid. ducts; transverse seams on all ducts; Ul181A or 181B tapes and mastics
Mechanical fasteners and sealants used to connect ducts and air distribution equipment
Hot water pipe Insulation: 1 In. for pipes <=1.5 in. and 2 in. for pipes >1.5 in, Chilled waterlrefrigerant/brine pipe insulation: 1
in. for pipes <=1.5 in, and 1.5 in. for pipes >1.5 in. Steam pipe insulation: 1,5 In. for pipes <=1,5 in, and 3 in. for pipes >1,5
in.
07.
DB.
09.
010.
011.
012.
Exception: Piping within HV AC equipment
Exception: Fluid temperatures between 55 and 105 degrees F
Exception: Fluid not heated or cooled
Exception: Runouts <4 ft in length
o 13, Operation and maintenance manual provided to building owner
o 14. Balancing devices provided in accordance with 603,15 of Mechanical Code for New York State
o 15. Newly purchased service water heating equipment meets the efficiency requirements
o 16, Water heater temperature controls: 110 degrees F for dwelling units or 90 degrees F for other occupancies
o 17,. Stair and elevator shaft vents are equipped with motorized dampers
Section 5: Compliance Statement
Compliance Statement: The proposed mechanical design represented in this document is consistent with the building plans,
specifications and other calculations submitted with this permit application, The proposed mechanical systems have been designed
to meet the New York State Energy Conservation Construction Code requirements in COMcheck Version 3,2,0 and to comply with
the mandatory requirements in the Requirements C ecklist.
~~~/? ~Lt-n,~4IM
Principal Mechanical Designer-Name
L/ /3)Ct!"
Oaf. .
Sound View Inn Reconstruction of Motel
Page 70f9
COMcheck Software Version 3.2.0
Mechanical Requirements
Description
New York State Energy Conservation Construction Code
Report Date:
Data filename: P:\2005\SVlnn\05-01 Reconstruction\Design\EnergyCalcs 03 31 06.cck
The following list provides more detailed descriptions of the requirements in Section 4 of the Mechanical Compliance Certificate.
Requirements Specific To: HVAC System 1 :
1. Each zone of a multiple~zone system must have its own temperature control device.
2. Hydronic heating and cooling coils must be equipped with a way to pressure test connections and measure and balance water
flow and pressure.
3. An integrated air economizer is required for individual cooling systems over 65 kBtu/h in the selected climate. An integrated
economizer allows simultaneous operation of outdoor-air and mechanical cooling.
Exception: An economizer is not required because high-efficiency air-conditioning equipment has been specified. To
qualify, the air conditioner must meet the following minimum efficiency: 11.4 EER
4. Systems serving multiple thermostatic control zones must be variable-flow systems. Zone terminal controls must reduce the
flow of primary supply air before reheating, recooling, or mixing air streams.
5. Multiple-zone systems must include controls capable of resetting the supply air temperature by at least 25% of the difference
between the design supply air temperature and the design room temperature.
Requirements Specific To: Water Heating 1 :
1. Piping for the specified circulating service hot water system must be insulated with a minimum of 1-in. insulation having a
conductivity no >0.28 Btu-in/(h-ft2-degrees F).
2. Circulating service hot water systems must have a time switch control that can automatically turn off the system during
unoccupied hours.
Generic Requirements: Must be met by all systems to which the requirement is applicable:
1. Design heating and cooling loads for the building must be determined using procedures in the ASHRAE Handbook of
Fundamentals or an approved equivalent calculation procedure.
2. All equipment and systems must be sized to be no greater than needed to meet calculated loads. A single piece of equipment
providing both heating and cooling must satisfy this provision for one function with the capacity for the other function as small
as possible, within available equipment options.
Exception: The equipment and/or system capacity may be greater than calculated loads for standby purposes. Standby
equipment must be automatically controlled to be off when the primary equipment and/or system is operating.
Exception: Multiple units of the same equipment type whose combined capacities exceed the calculated load are allowed
if they are provided with controls to sequence operation of the units as the load increases or decreases.
3. Each heating or cooling system serving a single zone must have its own temperature control device.
4. Each humidification system must have its own humidity control device.
5. Thermostats controlling both heating and cooling must be capable of maintaining a 5 degrees F deadband (a range of
temperature where no heating or cooling is provided).
Exception: Deadband capability is not required if the thermostat does not have automatic changeover capability between
heating and cooling.
6. The system or zone control must be a programmable thermostat or other automatic control meeting the following criteria:a)
capable of setting back temperature to 55 degrees F during heating and setting up to 85 degrees F during coolingb) capable of
automatically setting back or shutting down systems during unoccupied hours using 7 different day schedulesc) have an
accessible 2-hour occupant overrided) have a battery back-up capable of maintaining programmed settings for at least 10
hours without power.
Exception: A setback or shutoff control is not required on thermostats that control systems serving areas that operate
continuously.
Exception: A setback or shutoff control is not required on systems with total energy demand of 2 kW (6,826 Btu/h) or
less.
7. Outdoor-air supply systems with design airflow rates >3,000 cfm of outdoor air and all exhaust systems must have dampers
Sound View Inn Reconstruction of Motel
Page 8 of 9
. ,
that are automatically closed while the equipment is not operating.
8. The system must supply outside ventilation air as required by Chapter 4 of the Mechanical Code for New York State. If the
ventilation system is designed to supply outdoor-air quantities exceeding minimum required levels, the system must be
capable of reducing outdoor-air flow to the minimum required levels.
9. Air ducts must be insulated to the following levels:a) Supply and return air ducts for conditjone~ air located in unconditioned
spaces (spaces neither heated nor cooled) must be insulated with a minimum of R-5. Unconditioned spaces include attics,
crawl spaces, unheated basements, and unheated garages. b) Supply and return air ducts and plenums must be insulated to a
minimum of R-8 when located outside the building.c) When ducts are located within exterior components (e.g., floors or roofs),
minimum R-8 insulation is required only between the duct and the building exterior.
Exception: Duct insulation is not required on ducts located within equipment.
Exception: Duct insulation is not required when the design temperature difference between the interior and exterior of the
duct or plenum does not exceed 15 degrees F.
10. All joints, longitudinal and transverse seams, and connections in ductwork must be securely sealed using weldments;
mechanical fasteners with seals, gaskets, or mastics; mesh and mastic sealing systems; or tapes. Tapes and mastics must be
listed and labeled in accordance with UL 181A or UL 1818.
11. Mechanical fasteners and seals, mastics, or gaskets must be used when connecting ducts to fans and other air distribution
equipment, including multiple-zone terminal units.
12. All pipes serving space-conditioning systems must be insulated as follows: Hot water piping for heating systems: 1 in. for pipes
<=11/2-in. nominal diameter 2 in. for pipes >1 1/2-in. nominal diameter. Chilled water, refrigerant, and brine piping systems: 1
in. insulation for pipes <=1 1/2-in. nominal diameter 11/2 in. insulation for pipes >1 1/2-in. nominal diameter. Steam piping: 1
1/2 in. insulation for pipes <=1 1/2-in. nominal diameter 3 in. insulation for pipes >1 1/2-in. nominal diameter.
Exception: Pipe insulation is not required for factory-installed piping within HVAC equipment.
Exception: Pipe insulation is not required for piping that conveys fluids having a design operating temperature range
between 55 degrees F and 105 degrees F.
Exception: Pipe insulation is not required for piping that conveys fluids that have not been heated or cooled through the
use of fossil fuels or electric power.
Exception: Pipe insulation is not required for runout piping not exceeding 4 ft in length and 1 in. in diameter between the
control valve and HV AC coil.
13. Operation and maintenance documentation must be provided to the owner that includes at least the following information:a)
equipment capacity (input and output) and required maintenance actionsb) equipment operation and maintenance manualsc)
HVAC system control maintenance and calibration information, including wiring diagrams, schematics,.and control sequence
descriptions; desired or field-determined set points must be permanently recorded on control drawings, at control devices, or,
for digital control systems, in programming commentsd) complete narrative of how each system is intended to operate.
14. Each supply air outlet or diffuser and each zone terminal device (such as VAV or mixing box) must have its own balancing
device. Acceptable balancing devices include adjustable dampers located within the ductwork, terminal devices, and supply air
diffusers.
15. Service water heating equipment must meet minimum Federal efficiency requirements included in the National Appliance
Energy Conservation Act and the Energy Policy Act of 1992, which meet or exceed New York State Energy Conservation
Code. New service water heating equipment can be assumed to meet these requirements.
16. Water-heating equipment must be provided with controls that allow the user to set the water temperature to 110 degrees F for
dwelling units and 90 degrees F for other occupancies. Controls must limit output temperatures of lavatories in public facility
restrooms to 110 degrees F.
17. Stair and elevator shaft vents must be equipped with motorized dampers capable of being automatically closed during normal
building operation and interlocked to open as required by fire and smoke detection systems. All gravity outdoor air supply and
exhaust hoods, vents, and ventilators must be equipped with motorized dampers that will automatically shut when the spaces
served are not in use. Exceptions: - Gravity (non-motorized) dampers are acceptable in buildings less than three stories in
height above grade. - Ventilation systems serving unconditioned spaces.
Sound View Inn Reconstruction of Motel
Page 9 of 9
,
, ,
,
J.R. Holzmacher P.E., LLC
300 Wheeler Road, Suite 303, Hauppauge, New York 11788-4300
Tel: (631) 234-2220 Fax: (631) 234-2221 e-mail: iufo@holzmacher.com
--~..--.,
April 12, 2006
f. ::-,
. '
"
\
," f' "\:
\ ~ .
'.
\1'"
<;,1,11
,
Mr. Michael J. Verity
Chief Building Inspector
Town of South old Building Department
Southold Town Hall
53095 Main Road
P.O. Box 1179
Southold, New York 11971-1179
, "
~PR\3( ~
," J
-
,
\ _N.
---'
Re: Sound View Inn - Motel, Greenport
Proposed Re-construction
Dear Mr. Verity:
In response to your request to revise the floor plans to reflect handicap accessibility for the workout
room bathroom, we provide the enclosed plan sheet for your review. Also for your reference, we have
included the Underwriters Laboratory UL 263 Fire Resistance Ratings information with respect to the
2 hour rated masonry wall construction on the east and west sides of the Lobby. The "UL Online
Certifications Directory" indicates this wall construction as Design No. U905. If the concrete block
cores are filled with grout, which they will be, the UL tested design indicates "add 2 hr to
classification.
We hope the enclosed meets with your approval and if there are any additional comments please do
not hesitate to call.
Sincerely,
J. R. Holzmacher, P.E., LLC
An"'ooy J. z,J,k.a~
AJZ/az
Enc!.
CC: Ellen Weiderlight
P:\2005\SVINN\05-01\Correspondence\Task 2A 2B Town Bldg Dept\TOS Bldg Response 04 1206 Review.doc
The Third Generation of Excellence
In Water Supply, Water Resources, Civil and Environmental Engineering
.I
~XUV.U905 - Fire Resistance Ratings - ANSI/UL 263
Page 1 of2
.
.
UL Online Certifications Directory
BXUV.U90S
Fire Resistance Ratings - ANSI/UL 263
Paae Bottom
Fire Resistance Ratings - ANSI/UL 263
See General Information for Fire Resistance Ratlnns . ANSI/Ul 263
Design No. Ug05
March 17, 2004
Bearing Wan Rating - 2 HR.
.Nonbearlng Wan Rating - 2 HR
""'"--....,..It
1" .J,I"
_._-~._--
- -....- .......... -........ ---
Tf
i
I
~
! I, ,D" :-;-:" IJ .. "";E~' 'I . .~ .....,' ,,~. ~lf~' .- v' . :Jl
m(~tl{"im:;~i1 ' ::uonw U;.~O' '. ~ .()~:q5f1~".II~
tv. -:;J i,J!J..v,. . ,'-. .' .' f' ..t \.. :.,:.; "1
J ','0 \ ..... It~".. ,1 V, _ -.' " . I"" ..... t>-. - ,
~ ' '. 'I . '.' _" . l\' .... _ ',. .oM
, ~.. 'C!:Y' HOl'izontol Section
o
-r
7.jiS'MIN.
___1....",,'_.
1. Concrete Blocks* - Various designs. Classification 0-2 (2 hr).
See Concrete Blocks category for list of eligible manufacturers.
2. Mortar - Blocks laid In full bed of mortar, nom. 3/8 in. thick, of not less than 2-1/4 and not more than 3-1/2 parts of dean sharp
sand to 1 part Portland cement (proportioned by volume) and not more than 50 percent hydrated lime (by cement volume). Vertical
joints staggered.
3. Portland Cement Stucco or Gypsum Plaster - Add 1/2 hr to dasslficatlon If used. Where combustible members are framed In
wall, plaster or shJcco must be applied on the face opposite framing to achIeve a max. Classlflcatlon of 1-1/2 hr. Attached to concrete
blocks (Item 1).
4. Loose Masonry Fill - If all core spaces are filled with loose dry expanded slag, expanded day or shale (Rotary Kiln Process), water
repellant vermiculite masonry fill Insulation, or silicone treated perlite loose fill Insulation add 2 hr to dasslficatlon.
5. Foamed Plastlc:* - (Optional-Not ShOWn) - 1-1/2 In. thick max, 4 ft wide sheathing attached to concrete blocks (Item 1).
THE DOW CHEMICAL CO - Type Thermax
*Bearlng the UL Classification Mark
last Uodated on 2004-03-17
Ouestlons?
Notice of Dlsdalmer
fIgtlQo
Coovrlaht It> 2006 Underwriters laboratories Inc,(8
The appearance of a company's name or product In this database does not In Itself assure that products so Identified have been manufactured under Ul's Follow-Up
Servlce. Only those products bearing the UL Mark should be considered to be Usted and covered under Ul's Follow-Up Service. Always look for the Mark on the
http://database.ul.com/cgi-bin/XYV/template/LlSEXT/1FRAMElshowpage.html?n. .. 4/12/2006