HomeMy WebLinkAbout32164-Z FORM NO. 4 TOWN OF SOUTHOLD BUILDING DEPARTMENT Office of the Building Inspector Town Hall Southold, N.Y. CERTIFICATE OF OCCUPANCY No: Z-32191 Date: 02/07/07 THIS CERTIFIES that the building ADDITION & ALTERATION Location of Property: 1660 INDIAN (HOUSE NO.) County Tax Map No. 473889 Section 86 NECK LA (STREET) Block 4 PECONIC (HAMLET) Lot 6.1 Subdivision Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated JUNE 22, 2006 pursuant to which Building Permit No. 32164-Z dated JUNE 28, 2006 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is ADDITION & ALTERATION TO AN EXISTING SINGLE FAMILY DWELLING AS APPLIED FOR. The certificate is issued to JULIANA ZINGER (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL N/A ELECTRICAL CERTIFICATE NO. 3012920 01/25/07 PLUMBERS CERTIFICATION DATED 02/06/07 PECONIC PLUMBING&HEATING Rev. 1/81 7&5--lq /0 FER 6 ?u.. f :), Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new nse: I. Final survey of property with accurate location of all buildings, property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/1 0 of 1 % lead. 5. Commercial building, industrial building, multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. I\., For existing buildings (prior to April 9, 1957) non-conforming uses, or buildings and "pre-existing" land uses: I, Accurate survey of property showing all property lines, streets, building and unusual natural or topographic features, 2, A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied, the Building Inspector shall state the reasons therefor in writing to the applicant C. Fees 1. Certificate of Occupancy - New dwelling $25,00, Additions to dwelling $25.00, Alterations to dwelling $25,00, Swimming pool $25.00, Accessory building $25,00, Additions to accessory building $25.00, Businesses $50,00. 2, Certificate ofOccupaucy on Pre-existing Building - $100,00 3. Copy of Certificate of Occupancy - $,25 4, Updated Cel1ificate of Occupancy - $50,00 5. Temporary Certificate of Occupancy - Residential $15,00, Commercial $15.00 Date. J-'f. --c? New Construction: ./ Old or Pre-existing Building: ( chcck one) ~rJ(C- Hamlet Location of Property: / lAo House No. Owner or Owners of Property: JVf.-.IIt,.J* ..:C.u 0 I rt-J ,..j1811-- L4-. Street ~I ,J~l:::<""L Suffolk County Tax Map No 1 000, Section Block Lot Subdivision Pennit No, '32..1 b~ Date of Permit. Health Dept. Approval: Filed Map, ___.__ Lot: Applicant: Underwriters Approval: Plarming Board Approval: Request for: Temporary Certificate Final Certificate: / (check one) Fee Submitted: $ &..<<. 717~ r co-l3)I~[ FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 32164 Z Date JUNE 28, 2006 permission is hereby granted to: JULIANA ZINGER 418 EAST 59TH ST APT 26 NEW YORK,NY 10022 for : ADDITION & ALTERATIONS TO AN EXISTING SINGLE FAMILY DWELLING AS APPLIED FOR at premises located at 1660 INDIAN NECK LA PECONIC County Tax Map No. 473889 Section 086 Block 0004 Lot No. 006.001 pursuant to application dated JUNE 22, 2006 and approved by the Building Inspector to expire on DECEMBER 28, 2007. Fee $ 285.00 L~ I Authorized Signature ORIGINAL Rev. 5/8/02 l!I~~~.l!I I BY THIS CERTIFICATE OF COMPLIANCE THE :3 c. - - 'i - ~- J ~ I NEW YORK BOARD OF FIRE UNDERWRITERS I ~ BUREAU OF ELECTRICITY ~ ~ 40 FULTON STREET - NEW YORK, NY 1 0038 ~ ~ CERTIFIES THAT ~ ~ ~ ~ Upon the application of upon premises owned by ~ ~ ~ ~ PAUL R. BURNS JULIANA ZINGER ~ ~ PO BOX 1061 1660 INDIAN NECK LANE ~ I SOUTHOLD, NY 11971-0932, PECONIC, NY 11958 I ~ Located at 1660 INDIAN NECK LANE PECONIC, NY 11958 ~ ~ 3012920 3012920 ~ ~ Application Number: Certificate Number: ~ ~ Section: Block: Lot: Building Permit: BDC: ns11 ~ ~ Described as a occupancy, wherein the premi~s~e~t~ci system consisting of ~ ~ electrical devices and wiring, described below, located in/on the premises at: ~ ~ Second Floor, 2nd floor add, ~ ~ A visual inspection of the premises electrical system, limited to electrical devices and wiring to the extent detailed ~ ~ herein, was conducted in accordance with the requirements of the applicable code and/or standard ~ ~ promulgated by the State of New York, Department of State Code Enforcement and Administration, or other ~ ~ authority having jurisdiction, and found to be in compliance therewith on the 25th Day of January, 2007. ~ ~ Name OTY Rate Ratin. Circuit ~ ~ ~ Miscellaneous ~ ~ 2nd floor addition ~ ~ Alarm and Emergency Equipment ~ ~ Sensor Carbon Monoxide ~ ~~ ~ ~ ~ Appliances and Accessories ~ ~ Exhaust Fan F.H.P. ~ ii!l Wiring and Devices reJ ~~ ~ ~ ~~ ~~ ~ ~~ ~~ ~ rn! Receptacle General Purpose rn! ~ Switch General Purpose ~ ~ Paddle Fan ~ ~ Receptacle GFCI ~ ~ ~ ~ ~ ~ ~ 1 ~ 1 ~ ~ ~ I This certificate may not be altered in any way and is validated only by the presence of a raised seal at the location indicated. ~ l!I~ii!Jii! ~l!I 1 0 3 0 2 0 7 0 7 0 26 0 17 0 17 0 3 0 2 0 Town Hall, 53095 Main Road P.O. Box 1179 Southold, New York 11971-0959 Fax (631) 765-9502 Telephone (631) 765-1802 BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATION Date: ). (; 07 Building Permit No. 32--161 Owner: :JUL1/"rJA- ~ ....JGt~ (please print) Plumber: PeflOV'\. t'~ P4-1-f (please print) I certify that the solder used in the water supply system contains less than 2/10 of 1 % lead. l~ ~ ~ /~ ~ ~~ umbers Si ' Sworn to before me this day of ,20 l)~' 0 d?~ Notary Public, S~uS"~\~County V1CKll. LOPl:R Nobry Public, Slate of New YoI1I NO.OIL06070081 Qualified in SUffolk Coonlyq Commissianfllpires ,::J II 1'0 .. j)'--l~'f~ TOWN OF SOUTHOLD BUILDING DEPT. 765.1802 INSPECTION [ ] FOUNDATION 1 ST [ ] FOUNDATION 2ND [ ] FRAMING I STRAPPING [ ] FIREPLACE & CHIMNEY [ ] FIRE RESISTANT CONSTRUCTION REMARKS: [ ] ROUGH PLBG. [ ] ~ULATION [v] FINAL [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT PENETRATION eo DATE 1re. Ie 7 ( . INSPECTOR JAMES). DEERKOSKl, P.E. 260 Deer Drive Mattituck, N.Y. 11952 (631) 298-7116 FEB 5? Date: January 30, 2007 To: Town of South old Re: StrappinWfrarI1inWPlumbinglInsulation Inspections Zinger 1660 Indian Neck La. Peconic, NY Permit# 32164Z To Whom It May Concern: This letter certifies that all wind strapping on the above mentioned project is in tact, and meets all state and local building codes. A FramingIPlumbinglInsulation Inspection was also Performed on this Structure, and all framing, Insulation, and Plumbing was done correctly and also meets all state and local building codes. A pressure test was also performed on the waste/water plumbing systems. Any questions please feel free to call. .,<,~; ,<~~- /i~~ 0 . . EW},>::-:.. f{ ~~\;:...\.o....E. '.. ....'\~~;~ t ~ '\,','.~ ..-{-:-,:;\ " "c.. . \ ~\ 'JiC "") ~',')-~~>:-""'\< 1 0: ,\ (') , '..' '.... R.......,.....,.. . '.. '.. I ~U/l. ~ \~, ,"<'~::'::.;,#-''3-';i',>::/ \$ w, ~C~~.' i~~::~(<~()f:!'.7:;.:( .:.~/~~. 7 ~;~_#'",~;' ~S~9'S?:' ~,_'.':~'_"':;.c.~~ \\ \ \ Sincerely \, \ J ames ~. Deerkoski P .E. ~\ COMMENTS .. !< ~.." U~ ~. e; r .., ~"" FIEW INSPECTION REPORT DATE FOUNDATION (1ST) ------------------------------------ FOUNDATION (2ND) . . ROUGH FRAMING & PLUMBING INSULATION PER N. y, STATE ENERGY CODE FINAL '. 4 . . . . D:l> ,., . -t ~ . . z ~O (;' ~ [) ~ ~ .) i"l ~.., . , . . 'r-- ",. .:c, .(/ ,,< (-c (':; (;- ~ - t" r: ~ r- .., ;J/L./() A. j ~) 7/'l G_ 1~ ~ , / ''rn..d...1 f7M-r 8-K hl,e. (' r1 ~ .^ "T"'"7'A7"";' -..- ~ -=-. ; /' ' r / A<~ /,77 -p . N . ADDmONAL COMMENTS , (~ " ~ f\, 0 ::E LI~" c " \..-. , . . )::. > :'0 . . 4 t~ .." ~~ .., - :j ~ T~ - ::= ~ ~ ( ;! o 0 o ~ --L- ~ 'f/ , TOWN OF SOUTHOLD BUILDING DEPARTMENT 'fOWN HALL SOUTHOLD, NY 11971 TEL: (631) 765-1802 FAJl:(631)765-9502 www.northfork.netlSoutholdJ PERMIT NO. BUILDING PERMIT APPLICATION CHECKLIST }:2/r;,<(b Do you have or need the following, betore Bppl)'ing? Board of I lealth 4 sets of Building Plans Planning Board approval_~_~.~ Survey Check SepticFonn~~_.~ N.Y.S.D.E.C. Trust~s (:ontH~t: Exom;n""#,20 06 Approved . 20 0 h' Disapproved ale _ Mail to: Expiration ~__. .n l 'ff.20/)2 ...-- .. Phone "" ~R 'L 'L' o APPLICATION FOR BUILDING PERMIT Date : .' i INSTRUCTIONS I .-" \~ThiS 'application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 3 sets of plans, accurate plot plan to scale. Fee according to schedule. b. Plot plan showing location oflat and of buildings on premises. relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance ofBuitding Permit. d. Upon approval of this application., the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e. No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. ( Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. Ifno zoning amendments or other regulations affecting the property have been enacted in the interim, the Building Inspector may authorize, in writing, the extension of the pennit for an addition six months. Thereafter, a new permit shall be required. APPLlCA nON IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of South old, Suffolk County, New York, and other applicable Laws, Ordinances or Regulations, for the construt.1ion of buildings, additions, or alterations or for 0 demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances, building code, 0 in , and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. .20_ (Signature of applicant or name, if a corpomtion) IbbC l~;'" 'I-- ~k I <=>-VI>" ?.e.d)",\~"h~g~ySOfapeli~qS9 - State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder nWl0tR, Nameofownerofpremises Ci-\<<-\"")I1AKl ~TScN ~ ;:JU,.L-\AtJA 7/J-.JG-t:Q (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. Plumbers License No. Electricians License No. Other Trade's License No. I. Location of land on which proposed work will be done: \ J,bO \V\&;\~'" Nec.k \ all\Q.. House Number Street ?eCL:>v1.'C Hamlet County Tax Map No. 1000 S~ Subdivision N (Name) t Sf;, Block 04 Filed Map No. Lot {Q. ( Lot - 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing nse and occupancy ~l ~ b. Intended use and occupancy ~L~ ~ , 3. Nature of work (check which applicable): New Building Repair Removal Demolition Addition Other Work Alteration X ~ fW.M~.' (Description) 4. Estimated Cost Fee (To be paid on filing this application) 5. If dwelling, number of dwelling Wlits---!---- Number of dwelling Wlits on each floor _, If garage, number of cars \ 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. N I A 7. Dimensions ofe.;si,sting structures, if any: Front--3 8 Rear ~ Depth ~ Height --:a D T Number of Stories '2.. Dimensions of ~e.!tructure with atterations or add~ions: Front '18 Depth :..::c Height ~ :t:..--Num~tories - Rear~ ~ 8. Dimensions of entire new construction: Front Height __ Number of Stories 10. Date of Purchase l4 '1. ~jRear 2000 170.'(, Rear Depth ---' --- Depth 2GO+ I ~.(>/.J luUN~Fo 9. Size of lot; Front Name of Former Owner I J. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation? YES_ NOX. 13. Will lot he re-graded? YES_NO X.WilI excess fill he removed from premises? YES_ NO~ 14.NarnesofOwnerofJ)J,CmisetUIU$T1~ ~~N . ~o. NarneofArehitect c:./UJ.S.T:OP/.I.C4..' ddresJ-'bfb>KA?J ~"n__~ 72:Z..7BbS Name of Contractor Address Phone No. 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? "YES _NO~ " IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAYBE REQUIRED. b. Is this property within 300 fcet of a tidal wetland? " YES_NO_ " IF YES, D.E,C. PERMITS MAYBE REQUIRED, 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. / 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. ^J 1A IY/~ - STATE OF NEW YORK) SS: COUNTY OF ) CH R.l~\l A N rz..uf?,ER..~ being duly sworn, deposes and says that (s)be is the applicant (Name of individual signing contra(...1) above named, (S)He is the nw'f..JER (Contra(...1l.)r, Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perfurm or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. k Signature of Applicant Sworn lP~ore me this) 'I b- day of I utct" 20.lJ.0. ct}i.Y:A{f.( Yl O{,'('('d: 1.(\- Notary Public KATHLEEN COCCARO Notary Public - State of New York NO. 01 C06022266 Qualified in Bronx C nty My Commission Expires' I \ o~D- "66-4--~, I - OWNER ~.'..tL C1:l.ii~ I;;., 8+0 / 2-07J I II tP 0-0 ---,. 3~!l~1 i n _ PlcT; ~~A- H'::'t;',.~,~ I , ~"...... TOWN OF SOUTHOLD PR6l>>~TY RECORD CARD STREET / (PO VILLAGE Tl'ld'iyn \-.\eCK L0fle.. Y('conlc... ACR. ,G/ \ <6 REMARKS TYPE OF BLD. -.---- DIST. SUB. LOT \ 5 \!\l i ld ~o.\ s PROP. CLASS D ::<: 2-1 TOTAL -(\lIe..... FRONTAGE ON WATER TILLABLE FRONTAGE ON ROAD W()c;,D~N)~ 3~ DEPTH MEADOWLAND . BULKHEAD HOUSE/LOT , TOTAL \ \1$12- 86-4-6.1 02/02 "'-------,--~_.-.._-_...._,----_._-- ~ 2- Extension Patio ,5/) ,25 ~v'" Porch Breezeway ~ GaraQe R/IX MT/C- ~ 2-4 Y 2-4- ::::: 511 2- .AC x~~ _:_f;.y,y.:...../l./ . so - Pool uQ CaE ."""', /3. t11YD /fOCi -1--- /'iG'\ E~" 17> 9'5- t'Jto-~ I /) ~", _ ___ -::::-. -k ~;,uv/ .' -?v ~ ! '-c_~'.AJY-g:;:CI.L" ,<.-1--><1""5;;;-;(-- I"-'" c '. ~ . ~I ~ I ;TV. " I, d VII ~ N L.o ~lfI , i-? !J.., he. I 1'-' Y I -- ~I TI 7l: .;1,8 -. OlOR 3'; M rr Ztito 'ifu, Foundation Basement Bath 3 Dinette Floors Kit. / Interior Finish LA. } \ 5 (1) Heat D.A. Woodstove BA. Z ( I / ( / Attic Rooms 1st Floor Rooms 2nd Floor Ext. Walls Fire Place Dormer Driveway --"._' Iz,2-'1'7 O~J ~:;--'r \ .' 3' ~ VI",R 7- )., Permit Number , ,c~ \ ,,'_ "~'" '-'"J~:,~~':'- ~ \.'::..:-~_c'- REsCtIeCkCompliance Certificate Checked By/Date New York State Energy Conservation Construction Code REScheckSoftware Version 3.5 Release Ie Data filename: C:\Program Files\ChecklRESchecklZinger Rescheck.rck PROJECT TITLE: Zinger project COUNTY: Suffolk STATE: New York IIDD: 5750 CONSTRUCTION TYPE: Detached I or 2 Family HEATING TYPE: Non-Electric DATE: 03/16/06 DATE OF PLANS: 2006 PROJECT DESCRIPTION: Zinger/Robertson Residence Indian Neck Lane Southold , NY COMPLIANCE: Passes Maximum UA = 206 Your Home UA = 180 12.6% Better Than Code (VA) Glazing or Door U-Factor UA Gross Area or Perimeter Cavity Cont. R-Value R-Value Ceiling I: Flat Ceiling or Scissor Truss 590 30.0 0.0 21 Ceiling 2: Cathedral Ceiling (no attic) 600 19.0 0.0 30 Skylight I: Wood Frame:Double Pane with Low-E 24 0.420 10 Wall I: Wood Frame, 16" O.c. 840 19.0 0.0 45 Window I: Wood Frame:Double Pane with Low-E 96 0.320 31 Floor I: All-Wood Joist/Truss:Over Unconditioned Space 1300 30.0 0.0 43 Furnace I :-Porced Hm Air, 711 AFut ---- --- Air Conditioner I: Electric Central Air, 10 SEER COMPLIANCE STATEMENT: The proposed building represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed systems have been designed to meet the New York State En gy Co a 'on on ction Cod.~.!equirements. When a Registered Design Professional has stamped and signed this page, t yare all tin that the st;tif~is)h~P.\t"n~ledge, belief, and professional judgment, such plans or specifications are i complia e lth this . '.. ",' '.'" . BuilderIDesigner Date ~ UtJ fL, ()(p in \' - , ,\ ,: j I . a . . ,I (C:~;.::> / <~{;~/! " ... ~"-" " -\:>yo ~~'> r;_;~. \,',~ ',,;j'" ",,~., c' .. ,,~,;:;,;,'::;.,,;::-c~,;'::" REScheck Inspection Checklist New York State Energy Conservation Construction Code REScheckSoftware Version 3.5 Release Ie DA TE: 03/16/06 PROJECT TITLE: Zinger project Bldg. Dept. Vse Ceilings: ] 1. Ceiling I: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation Comments: 2. Ceiling 2: Cathedral Ceiling (no attic), R-19.0 cavity insulation Comments: Above-Grade Walls: [] 1. Wall I: Wood Frame, 16" O.c., R-19.0 cavity insulation Comments: Windows: [] 1. Window I: Wood Frame:Double Pane with Low-E, V-factor: 0.320 For windows without labeled V-factors, describe features: # Panes_Frame Type Thermal Break? [ ] Yes [ ] No Comments: -I I I I I I I I [ ] I I I [ ] I [ ] I [ ] I Skylights: 1. Skylight I: Wood Frame:Double Pane with Low-E, V-factor: 0.420 For skylights without labeled V-factors, describe features: # Panes_Frame Type Thermal Break? [ ] Yes [ ] No Comments: Floors: 1. Floor I: All-Wood JoistlTruss:Over Vnconditioned Space, R-30.0 cavity insulation Comments: Heating and Cooling Equipment: I. Furnace I: Forced Hot Air, 78 AFVE or higher Make and Model Number 2. Air Conditioner I: Electric Central Air, 10 SEER or higher Make and Model Number -Ail Lt;:;ilkA~e. ----- ---- Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. Recessed lights must be I) Type IC rated, or 2) installed inside an appropriate air-tight assembly with a 0.5" clearance from combustible materials. If non-Ie rated, the fixture must be installed with a 3" clearance from insulation. Vapor Retarder: Required on the warm-in-winter side of all non-vented framed ceilings, walls, and floors. Materials Identification: Materials and equipment must be installed in accordance with the manufacturer's installation instructions. Materials and equipment must be identified so that compliance can be determined. Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. Insulation R-values and glazing V-fuctors must be clearly marked on tbe building plans or specifications. Duct Insulation: [] Supply ducts in unconditioned attics or outside tbe building must be insulated to R-8. [] Return ducts in unconditioned attics or outside tbe building must be insulated to R-4. [] Supply ducts in unconditioned spaces must be insulated to R-8. [] Return ducts in unconditioned spaces (except basements) must be insulated to R-2. Insulation is not required on return ducts in basements. Duct Construction: [] All joints, seams, and connections must be securely fastened witb welds, gaskets, mastics (adbesives), mastic-plus-em bedded-fabric, or tapes. Duct tape is not permitted. Exception: Continuously welded and locking-type longitudinal joints and seams on ducts operating at less tban 2 in. w.g. (500 Pa). ] Ducts sball be supported every 10 feet or in accordance witb tbe manufacturer's instructions. ] Cooling ducts with exterior insulation must be covered witb a vapor retarder. ] Air filters are required in the return air system. ] Tbe HV AC system must provide a means for balancing air and water systems. Temperature Controls: [] Eacb dwelling unit bas at lesat one tbermostat capable of automatically adjusting tbe space temperature set point oftbe largest zone. Electric Systems: [] Separate electric meters are required for eacb dwelling unit. Fireplaces: [ Fireplaces must be installed witb tight fitting non-combustible fireplace doors. [ Fireplaces must be provided witb a source of combustion air, as required by tbe Fireplace construction provisions oftbe Building Code of New York State, tbe Residential Code of New York State or tbe New York City Building Code, as applicahle. Service Water Heating: Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. ] Insulate circulating hot water pipes to the levels in Table I. Circulating Hot Water Systems: [] Insulate circulating hot water pipes to the levels in Table I. Swimming Pools: [] All beated swimming pools must have an on/off heater switch and require a cover unless over 20% oftbe heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling-l'iping.lDSuIatioo, BV AC piping conveying fluids above 105 "F or chilled fluids below 55 "F must he insulated to the levels in Table 2. Table I: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Non-Circulating Runouts Circulating Mains and Runouts UP to I" Up to 1.2511 1.5" to 2.0" Over 2" 0.5 1.0 1.5 2.0 0.5 0.5 1.0 1.5 0.5 0.5 0.5 1.0 Heated Water Tern perature ( F) 170-180 140-160 100-130 Table 2: Minimum Insulation Thicknessfor HVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range (F) 2" Runouts 1" and Less 1.25" to 2" 2.5" to 4" Heating Systems Low Pressure/Temperature Low Temperature Steam Condensate (for feed water) Cooling Systems Chilled Water, Refrigerant, and Brine 201-250 1.0 1.5 1.5 2.0 [20-200 0.5 1.0 1.0 1.5 Any 1.0 1.0 1.5 2.0 40-55 0.5 0.5 0.75 1.0 Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only) FORM NO.3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 32164 Z Date JUNE 28, 2006 permission is hereby granted to: JULIANA ZINGER 418 EAST 59TH ST APT 26 NEW YORK,NY 10022 for : ADDITION & ALTERATIONS TO AN EXISTING SINGLE FAMILY DWELLING AS APPLIED FOR at premises located at 1660 INDIAN NECK LA PECONIC County Tax Map No. 473889 Section 086 Block 0004 Lot No. 006.001 pursuant to application dated JUNE 22, 2006 and approved by the Building Inspector to expire on DECEMBER 28, 2007. Fee $ 285.00 Authorized Signature COpy Rev. 5/8/02 -". r Vlfl.R '2. 3 Permit Number , i --' REsdteck Compliance Certificate Checked By/Date New York State Energy Conservation Construction Code REScheckSoftware Version 3.5 Release Ie Data filename; C;\Program Files\Check\RESchecklZinger Rescheck.rck PROJECT TITLE; Zinger project COUNTY; Suffolk STATE; New York HDD; 5750 CONSTRUCTION TYPE; Detached I or 2 Family HEA TING TYPE; Non-Electric DA TE; 03/16/06 DATE OF PLANS; 2006 PROJECT DESCRIPTION; ZingerlRobertson Residence Indian Neck Lane Southold , NY COMPLIANCE; Passes Maximum UA ~ 206 Your Home UA ~ 180 12.6% Better Than Code (UA) Ceiling I; Flat Ceiling or Scissor Truss Ceiling 2; Cathedral Ceiling (no attic) Skylight I; Wood Frame;Double Pane with Low-E Wall I; Wood Frame, 16" o.c. Window I; Wood Frame;Double Pane with Low-E Floor I; All-Wood Joist/Truss;Over Unconditioned Space Furnace I; Forced Hot Air, 78 AFUE Air Conditioner I; Electric Central Air, 10 SEER Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R- Value U-Factor UA 590 30.0 0.0 21 600 19.0 0.0 30 24 0.420 10 840 19.0 0.0 45 96 0.320 31 1300 30.0 0.0 43 COMPLIANCE STATEMENT; The proposed building represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed systems have been designed to meet the New York State En gy Co e a .on on uction Code requirements. When a Registered Design Professional has stamped and signed this page, t yare at! tin that the st ofhis/her knowledge, belief, and professional judgment, such plans or specifications are i complia e tth this Builderroesigner Date' W<J fL- o(P REScheck Inspection Checklist New York State Energy Conservation Construction Code REScheckSoftware Version 3.5 Release Ie DA TE: 03/16/06 PROJECT TITLE: Zinger project Bldg. Dept. Use Ceilings: I. Ceiling I: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation Comments: 2. Ceiling 2: Cathedral Ceiling (no attic), R-19.0 cavity insulation Comments: Above-G rade Walls: [] 1. Wall I: Wood Frame, 16" O.c., R-19.0 cavity insulation Comments: Windows: 1. Window I: Wood Frame:Double Pane with Low-E, U-factor: 0.320 For windows without labeled U-factors, describe features: # Panes_Frame Type Thermal Break? [ ] Yes [ ] No Comments: Skylights: 1. Skylight I: Wood Frame:Double Pane with Low-E, U-factor: 0.420 For skylights without labeled U-factors, describe features: # Panes_ Frame Type Thermal Break? [ ] Yes [ ] No Comments: Floors: [] 1. Floor I: All-Wood Joist/Truss:Over Unconditioned Space, R-30.0 cavity insulation Comments: Heating and Cooling Equipment: I. Furnace I: Forced Hot Air, 78 AFUE or higher Make and Model Number 2. Air Conditioner I: Electric Central Air, 10 SEER or higher Make and Model Number Air Leakage: Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. Recessed lights must be I) Type IC rated, or 2) installed inside an appropriate air-tight assembly with a 0.5" clearance from combustible materials. Ifnon-IC rated, the fixture must be installed with a 3" clearance from insulation. Vapor Retarder: [] Required on the warm-in-winter side of all non-vented framed ceilings, walls, and floors. Materials Identification: ] Materials and equipment must be installed in accordance with the manufacturer's installation instructions. ] Materials and equipment must be identified so that compliance can be determined. ] Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. Insulation R-values and glazing V-fuctors must be clearly marked on the building plans or specifications. Duct Insulation: [] Supply ducts in unconditioned attics or outside the building must be insulated to R-8. [] Return ducts in unconditioned attics or outside the building must be insulated to R-4. [] Supply ducts in unconditioned spaces must be insulated to R-8. [] Return ducts in unconditioned spaces (except basements) must be insulated to R-2. Insulation is not required on return ducts in basements. Duct Construction: All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives), mastic-plus-embedded-fubric, or tapes. Duct tape is not permitted. Exception: Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pal. Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions. Cooling ducts with exterior insulation must be covered with a vapor retarder. Air filters are required in the return air system. The HV AC system must provide a means for balancing air and water systems. Temperature Controls: Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space temperature set point of the largest zone. Electric Systems: Separate electric meters are required for each dwelling unit. Fireplaces: [] Fireplaces must be installed with tight fitting non-combustible fireplace doors. [] Fireplaces must be provided with a source of combustion air, as required by the Fireplace construction provisions ofthe Building Code of New York State, the Residential Code of New York State or the New York City Building Code, as applicable. Service Water Heating: Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. Insulate circulating hot water pipes to the levels in Table I. Circulating Hot Water Systems: Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: All heated swimming pools must have an on/off heater switch and require a cover unless over 20% ofthe heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: HV AC piping conveying fluids above 105 "F or chilled fluids below 55 "F must be insulated to the levels in Table 2. Heated Water Temperature ( F) 170-180 140-160 100-130 . Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Non-Circulatin~ Runouts Circulatin~ Mains and Runouts Up to 1" Up to 1.25" 1.5" to 2.0" Over 2" 0.5 1.0 1.5 2.0 0.5 0.5 1.0 1.5 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thicknessfor HVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Pipin~ System Types Ran~e ( F) 2" Runouts J" and Less 1.25" to 2" 2.5" to 4" Heating Systems Low PressurelT em perature Low Temperature Steam Condensate (for feed water) Cooling Systems Chilled Water, Refrigerant. and Brine 201-250 1.0 1.5 1.5 2.0 120-200 0.5 1.0 1.0 1.5 Any 1.0 1.0 1.5 2.0 40-55 0.5 0.5 0.75 1.0 Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only)