HomeMy WebLinkAbout32164-Z
FORM NO. 4
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
Office of the Building Inspector
Town Hall
Southold, N.Y.
CERTIFICATE OF OCCUPANCY
No: Z-32191
Date: 02/07/07
THIS CERTIFIES that the building ADDITION & ALTERATION
Location of Property: 1660 INDIAN
(HOUSE NO.)
County Tax Map No. 473889 Section 86
NECK LA
(STREET)
Block 4
PECONIC
(HAMLET)
Lot 6.1
Subdivision
Filed Map No.
Lot No.
conforms substantially to the Application for Building Permit heretofore
filed in this office dated
JUNE 22, 2006 pursuant to which
Building Permit No. 32164-Z
dated
JUNE 28, 2006
was issued, and conforms to all of the requirements of the applicable
provisions of the law. The occupancy for which this certificate is issued
is ADDITION & ALTERATION TO AN EXISTING SINGLE FAMILY DWELLING AS APPLIED
FOR.
The certificate is issued to JULIANA ZINGER
(OWNER)
of the aforesaid building.
SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL
N/A
ELECTRICAL CERTIFICATE NO.
3012920
01/25/07
PLUMBERS CERTIFICATION DATED
02/06/07 PECONIC PLUMBING&HEATING
Rev. 1/81
7&5--lq /0
FER
6 ?u..
f :),
Form No.6
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
TOWN HALL
765-1802
APPLICATION FOR CERTIFICATE OF OCCUPANCY
This application must be filled in by typewriter or ink and submitted to the Building Department with the following:
A. For new building or new nse:
I. Final survey of property with accurate location of all buildings, property lines, streets, and unusual natural or
topographic features.
2. Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 form).
3. Approval of electrical installation from Board of Fire Underwriters.
4. Sworn statement from plumber certifying that the solder used in system contains less than 2/1 0 of 1 % lead.
5. Commercial building, industrial building, multiple residences and similar buildings and installations, a certificate
of Code Compliance from architect or engineer responsible for the building.
6. Submit Planning Board Approval of completed site plan requirements.
I\., For existing buildings (prior to April 9, 1957) non-conforming uses, or buildings and "pre-existing" land uses:
I, Accurate survey of property showing all property lines, streets, building and unusual natural or topographic
features,
2, A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is
denied, the Building Inspector shall state the reasons therefor in writing to the applicant
C. Fees
1. Certificate of Occupancy - New dwelling $25,00, Additions to dwelling $25.00, Alterations to dwelling $25,00,
Swimming pool $25.00, Accessory building $25,00, Additions to accessory building $25.00, Businesses $50,00.
2, Certificate ofOccupaucy on Pre-existing Building - $100,00
3. Copy of Certificate of Occupancy - $,25
4, Updated Cel1ificate of Occupancy - $50,00
5. Temporary Certificate of Occupancy - Residential $15,00, Commercial $15.00
Date.
J-'f. --c?
New Construction:
./
Old or Pre-existing Building:
( chcck one)
~rJ(C-
Hamlet
Location of Property: / lAo
House No.
Owner or Owners of Property: JVf.-.IIt,.J*
..:C.u 0 I rt-J
,..j1811-- L4-.
Street
~I ,J~l:::<""L
Suffolk County Tax Map No 1 000, Section
Block
Lot
Subdivision
Pennit No, '32..1 b~ Date of Permit.
Health Dept. Approval:
Filed Map, ___.__ Lot:
Applicant:
Underwriters Approval:
Plarming Board Approval:
Request for:
Temporary Certificate
Final Certificate:
/
(check one)
Fee Submitted: $
&..<<. 717~ r
co-l3)I~[
FORM NO. 3
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
Town Hall
Southold, N.Y.
BUILDING PERMIT
(THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL
COMPLETION OF THE WORK AUTHORIZED)
PERMIT NO.
32164 Z
Date JUNE
28, 2006
permission is hereby granted to:
JULIANA ZINGER
418 EAST 59TH ST APT 26
NEW YORK,NY 10022
for :
ADDITION & ALTERATIONS TO AN EXISTING SINGLE FAMILY DWELLING AS
APPLIED FOR
at premises located at
1660 INDIAN NECK LA
PECONIC
County Tax Map No. 473889 Section 086
Block 0004
Lot No. 006.001
pursuant to application dated JUNE 22, 2006 and approved by the
Building Inspector to expire on DECEMBER 28, 2007.
Fee $
285.00
L~
I Authorized Signature
ORIGINAL
Rev. 5/8/02
l!I~~~.l!I
I BY THIS CERTIFICATE OF COMPLIANCE THE :3 c. - - 'i - ~- J ~
I NEW YORK BOARD OF FIRE UNDERWRITERS I
~ BUREAU OF ELECTRICITY ~
~ 40 FULTON STREET - NEW YORK, NY 1 0038 ~
~ CERTIFIES THAT ~
~ ~
~ Upon the application of upon premises owned by ~
~ ~
~ PAUL R. BURNS JULIANA ZINGER ~
~ PO BOX 1061 1660 INDIAN NECK LANE ~
I SOUTHOLD, NY 11971-0932, PECONIC, NY 11958 I
~ Located at 1660 INDIAN NECK LANE PECONIC, NY 11958 ~
~ 3012920 3012920 ~
~ Application Number: Certificate Number: ~
~ Section: Block: Lot: Building Permit: BDC: ns11 ~
~ Described as a occupancy, wherein the premi~s~e~t~ci system consisting of ~
~ electrical devices and wiring, described below, located in/on the premises at: ~
~ Second Floor, 2nd floor add, ~
~ A visual inspection of the premises electrical system, limited to electrical devices and wiring to the extent detailed ~
~ herein, was conducted in accordance with the requirements of the applicable code and/or standard ~
~ promulgated by the State of New York, Department of State Code Enforcement and Administration, or other ~
~ authority having jurisdiction, and found to be in compliance therewith on the 25th Day of January, 2007. ~
~ Name OTY Rate Ratin. Circuit ~ ~
~ Miscellaneous ~
~ 2nd floor addition ~
~ Alarm and Emergency Equipment ~
~ Sensor Carbon Monoxide ~
~~ ~ ~
~ Appliances and Accessories ~
~ Exhaust Fan F.H.P. ~
ii!l Wiring and Devices reJ
~~ ~ ~
~~ ~~ ~
~~ ~~ ~
rn! Receptacle General Purpose rn!
~ Switch General Purpose ~
~ Paddle Fan ~
~ Receptacle GFCI ~
~ ~ ~
~ ~
~ 1 ~ 1 ~
~ ~
I This certificate may not be altered in any way and is validated only by the presence of a raised seal at the location indicated. ~
l!I~ii!Jii! ~l!I
1 0
3 0
2 0
7 0
7 0
26 0
17 0
17 0
3 0
2 0
Town Hall, 53095 Main Road
P.O. Box 1179
Southold, New York 11971-0959
Fax (631) 765-9502
Telephone (631) 765-1802
BUILDING DEPARTMENT
TOWN OF SOUTHOLD
CERTIFICATION
Date: ). (; 07
Building Permit No.
32--161
Owner: :JUL1/"rJA- ~ ....JGt~
(please print)
Plumber: PeflOV'\. t'~ P4-1-f
(please print)
I certify that the solder used in the water supply system contains less than 2/10 of 1 %
lead.
l~ ~ ~
/~ ~ ~~
umbers Si '
Sworn to before me this
day of
,20
l)~' 0 d?~
Notary Public, S~uS"~\~County
V1CKll. LOPl:R
Nobry Public, Slate of New YoI1I
NO.OIL06070081
Qualified in SUffolk Coonlyq
Commissianfllpires ,::J II 1'0
..
j)'--l~'f~
TOWN OF SOUTHOLD BUILDING DEPT.
765.1802
INSPECTION
[ ] FOUNDATION 1 ST
[ ] FOUNDATION 2ND
[ ] FRAMING I STRAPPING
[ ] FIREPLACE & CHIMNEY
[ ] FIRE RESISTANT CONSTRUCTION
REMARKS:
[ ] ROUGH PLBG.
[ ] ~ULATION
[v] FINAL
[ ] FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT PENETRATION
eo
DATE 1re. Ie 7
(
.
INSPECTOR
JAMES). DEERKOSKl, P.E.
260 Deer Drive
Mattituck, N.Y. 11952
(631) 298-7116
FEB 5?
Date: January 30, 2007
To: Town of South old
Re: StrappinWfrarI1inWPlumbinglInsulation Inspections
Zinger
1660 Indian Neck La.
Peconic, NY
Permit# 32164Z
To Whom It May Concern:
This letter certifies that all wind strapping on the above mentioned project is in tact, and
meets all state and local building codes. A FramingIPlumbinglInsulation Inspection was
also Performed on this Structure, and all framing, Insulation, and Plumbing was done
correctly and also meets all state and local building codes. A pressure test was also
performed on the waste/water plumbing systems. Any questions please feel free to call.
.,<,~; ,<~~-
/i~~ 0 . . EW},>::-:..
f{ ~~\;:...\.o....E. '.. ....'\~~;~
t ~ '\,','.~ ..-{-:-,:;\
" "c.. . \ ~\
'JiC "") ~',')-~~>:-""'\< 1 0:
,\ (') , '..' '.... R.......,.....,.. . '.. '.. I ~U/l.
~ \~, ,"<'~::'::.;,#-''3-';i',>::/ \$ w,
~C~~.' i~~::~(<~()f:!'.7:;.:( .:.~/~~. 7
~;~_#'",~;'
~S~9'S?:'
~,_'.':~'_"':;.c.~~
\\
\
\ Sincerely
\,
\
J ames ~. Deerkoski P .E.
~\
COMMENTS
.. !<
~.."
U~
~. e;
r ..,
~""
FIEW INSPECTION REPORT DATE
FOUNDATION (1ST)
------------------------------------
FOUNDATION (2ND)
. .
ROUGH FRAMING &
PLUMBING
INSULATION PER N. y,
STATE ENERGY CODE
FINAL
'.
4
.
.
.
.
D:l>
,.,
. -t ~
.
.
z
~O
(;'
~
[)
~ ~
.) i"l
~..,
. ,
.
.
'r--
",.
.:c,
.(/
,,<
(-c
(':;
(;- ~
- t"
r: ~
r- ..,
;J/L./() A. j ~) 7/'l G_ 1~ ~
, / ''rn..d...1 f7M-r 8-K hl,e. (' r1 ~
.^ "T"'"7'A7"";' -..- ~
-=-. ; /' ' r
/ A<~
/,77
-p
.
N
. ADDmONAL COMMENTS
,
(~
" ~
f\, 0
::E
LI~"
c "
\..-.
, .
.
)::.
>
:'0
.
.
4
t~
.."
~~
..,
-
:j ~
T~
- ::=
~ ~
( ;!
o 0
o ~
--L- ~
'f/
,
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
'fOWN HALL
SOUTHOLD, NY 11971
TEL: (631) 765-1802
FAJl:(631)765-9502
www.northfork.netlSoutholdJ PERMIT NO.
BUILDING PERMIT APPLICATION CHECKLIST
}:2/r;,<(b
Do you have or need the following, betore Bppl)'ing?
Board of I lealth
4 sets of Building Plans
Planning Board approval_~_~.~
Survey
Check
SepticFonn~~_.~
N.Y.S.D.E.C.
Trust~s
(:ontH~t:
Exom;n""#,20 06
Approved . 20 0 h'
Disapproved ale _
Mail to:
Expiration
~__. .n
l 'ff.20/)2
...-- ..
Phone
""
~R 'L 'L'
o
APPLICATION FOR BUILDING PERMIT
Date
: .' i INSTRUCTIONS
I .-"
\~ThiS 'application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 3
sets of plans, accurate plot plan to scale. Fee according to schedule.
b. Plot plan showing location oflat and of buildings on premises. relationship to adjoining premises or public streets or
areas, and waterways.
c. The work covered by this application may not be commenced before issuance ofBuitding Permit.
d. Upon approval of this application., the Building Inspector will issue a Building Permit to the applicant. Such a permit
shall be kept on the premises available for inspection throughout the work.
e. No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector
issues a Certificate of Occupancy.
( Every building permit shall expire if the work authorized has not commenced within 12 months after the date of
issuance or has not been completed within 18 months from such date. Ifno zoning amendments or other regulations affecting the
property have been enacted in the interim, the Building Inspector may authorize, in writing, the extension of the pennit for an
addition six months. Thereafter, a new permit shall be required.
APPLlCA nON IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the
Building Zone Ordinance of the Town of South old, Suffolk County, New York, and other applicable Laws, Ordinances or
Regulations, for the construt.1ion of buildings, additions, or alterations or for 0 demolition as herein described. The
applicant agrees to comply with all applicable laws, ordinances, building code, 0 in , and regulations, and to admit
authorized inspectors on premises and in building for necessary inspections.
.20_
(Signature of applicant or name, if a corpomtion)
IbbC l~;'" 'I-- ~k I <=>-VI>"
?.e.d)",\~"h~g~ySOfapeli~qS9 -
State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder
nWl0tR,
Nameofownerofpremises Ci-\<<-\"")I1AKl ~TScN ~ ;:JU,.L-\AtJA 7/J-.JG-t:Q
(As on the tax roll or latest deed)
If applicant is a corporation, signature of duly authorized officer
(Name and title of corporate officer)
Builders License No.
Plumbers License No.
Electricians License No.
Other Trade's License No.
I. Location of land on which proposed work will be done:
\ J,bO \V\&;\~'" Nec.k \ all\Q..
House Number Street
?eCL:>v1.'C
Hamlet
County Tax Map No. 1000 S~
Subdivision N
(Name) t
Sf;,
Block 04
Filed Map No.
Lot {Q. (
Lot -
2. State existing use and occupancy of premises and intended use and occupancy of proposed construction:
a. Existing nse and occupancy ~l ~
b. Intended use and occupancy ~L~
~
,
3. Nature of work (check which applicable): New Building
Repair Removal Demolition
Addition
Other Work
Alteration X
~ fW.M~.'
(Description)
4. Estimated Cost Fee
(To be paid on filing this application)
5. If dwelling, number of dwelling Wlits---!---- Number of dwelling Wlits on each floor _,
If garage, number of cars \
6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. N I A
7. Dimensions ofe.;si,sting structures, if any: Front--3 8 Rear ~ Depth ~
Height --:a D T Number of Stories '2..
Dimensions of ~e.!tructure with atterations or add~ions: Front '18
Depth :..::c Height ~ :t:..--Num~tories
-
Rear~
~
8. Dimensions of entire new construction: Front
Height __ Number of Stories
10. Date of Purchase
l4 '1. ~jRear
2000
170.'(,
Rear Depth ---'
---
Depth 2GO+ I
~.(>/.J luUN~Fo
9. Size of lot; Front
Name of Former Owner
I J. Zone or use district in which premises are situated
12. Does proposed construction violate any zoning law, ordinance or regulation? YES_ NOX.
13. Will lot he re-graded? YES_NO X.WilI excess fill he removed from premises? YES_ NO~
14.NarnesofOwnerofJ)J,CmisetUIU$T1~ ~~N . ~o.
NarneofArehitect c:./UJ.S.T:OP/.I.C4..' ddresJ-'bfb>KA?J ~"n__~ 72:Z..7BbS
Name of Contractor Address Phone No.
15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? "YES _NO~
" IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAYBE REQUIRED.
b. Is this property within 300 fcet of a tidal wetland? " YES_NO_
" IF YES, D.E,C. PERMITS MAYBE REQUIRED,
16. Provide survey, to scale, with accurate foundation plan and distances to property lines.
/
17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. ^J 1A
IY/~ -
STATE OF NEW YORK)
SS:
COUNTY OF )
CH R.l~\l A N rz..uf?,ER..~ being duly sworn, deposes and says that (s)be is the applicant
(Name of individual signing contra(...1) above named,
(S)He is the nw'f..JER
(Contra(...1l.)r, Agent, Corporate Officer, etc.)
of said owner or owners, and is duly authorized to perfurm or have performed the said work and to make and file this application;
that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be
performed in the manner set forth in the application filed therewith.
k
Signature of Applicant
Sworn lP~ore me this) 'I
b- day of I utct" 20.lJ.0.
ct}i.Y:A{f.( Yl O{,'('('d: 1.(\-
Notary Public
KATHLEEN COCCARO
Notary Public - State of New York
NO. 01 C06022266
Qualified in Bronx C nty
My Commission Expires'
I \ o~D- "66-4--~, I
-
OWNER
~.'..tL
C1:l.ii~
I;;., 8+0
/ 2-07J
I
II tP 0-0
---,.
3~!l~1
i
n _ PlcT;
~~A- H'::'t;',.~,~
I
, ~"......
TOWN OF SOUTHOLD PR6l>>~TY RECORD CARD
STREET / (PO VILLAGE
Tl'ld'iyn \-.\eCK L0fle.. Y('conlc...
ACR. ,G/ \ <6 REMARKS
TYPE OF BLD.
-.----
DIST. SUB. LOT \
5 \!\l i ld ~o.\ s
PROP. CLASS D
::<: 2-1
TOTAL
-(\lIe.....
FRONTAGE ON WATER TILLABLE
FRONTAGE ON ROAD W()c;,D~N)~ 3~
DEPTH MEADOWLAND
.
BULKHEAD HOUSE/LOT
, TOTAL \
\1$12-
86-4-6.1 02/02
"'-------,--~_.-.._-_...._,----_._--
~
2-
Extension
Patio
,5/)
,25
~v'"
Porch
Breezeway
~
GaraQe
R/IX MT/C-
~
2-4 Y 2-4- ::::: 511
2- .AC x~~
_:_f;.y,y.:...../l./
. so
-
Pool
uQ
CaE
."""',
/3. t11YD
/fOCi
-1---
/'iG'\
E~"
17> 9'5- t'Jto-~
I /) ~", _ ___ -::::-.
-k ~;,uv/ .' -?v ~
! '-c_~'.AJY-g:;:CI.L" ,<.-1--><1""5;;;-;(--
I"-'"
c
'. ~ . ~I
~ I ;TV.
" I,
d VII ~ N L.o ~lfI
, i-? !J.., he. I 1'-' Y
I
--
~I TI
7l:
.;1,8 -.
OlOR
3';
M
rr Ztito 'ifu,
Foundation
Basement
Bath 3 Dinette
Floors Kit. /
Interior Finish LA. }
\ 5 (1) Heat D.A.
Woodstove BA. Z ( I
/ ( /
Attic
Rooms 1st Floor
Rooms 2nd Floor
Ext. Walls
Fire Place
Dormer
Driveway
--"._'
Iz,2-'1'7
O~J
~:;--'r
\
.'
3' ~
VI",R 7- )., Permit Number
, ,c~
\ ,,'_ "~'" '-'"J~:,~~':'-
~ \.'::..:-~_c'-
REsCtIeCkCompliance Certificate Checked By/Date
New York State Energy Conservation Construction Code
REScheckSoftware Version 3.5 Release Ie
Data filename: C:\Program Files\ChecklRESchecklZinger Rescheck.rck
PROJECT TITLE: Zinger project
COUNTY: Suffolk
STATE: New York
IIDD: 5750
CONSTRUCTION TYPE: Detached I or 2 Family
HEATING TYPE: Non-Electric
DATE: 03/16/06
DATE OF PLANS: 2006
PROJECT DESCRIPTION:
Zinger/Robertson Residence
Indian Neck Lane
Southold , NY
COMPLIANCE: Passes
Maximum UA = 206
Your Home UA = 180
12.6% Better Than Code (VA)
Glazing
or Door
U-Factor UA
Gross
Area or
Perimeter
Cavity Cont.
R-Value R-Value
Ceiling I: Flat Ceiling or Scissor Truss 590 30.0 0.0 21
Ceiling 2: Cathedral Ceiling (no attic) 600 19.0 0.0 30
Skylight I: Wood Frame:Double Pane with Low-E 24 0.420 10
Wall I: Wood Frame, 16" O.c. 840 19.0 0.0 45
Window I: Wood Frame:Double Pane with Low-E 96 0.320 31
Floor I: All-Wood Joist/Truss:Over Unconditioned Space 1300 30.0 0.0 43
Furnace I :-Porced Hm Air, 711 AFut ---- ---
Air Conditioner I: Electric Central Air, 10 SEER
COMPLIANCE STATEMENT: The proposed building represented in this document is consistent with the building plans,
specifications, and other calculations submitted with this permit application. The proposed systems have been designed to meet the
New York State En gy Co a 'on on ction Cod.~.!equirements. When a Registered Design Professional has stamped and
signed this page, t yare all tin that the st;tif~is)h~P.\t"n~ledge, belief, and professional judgment, such plans or
specifications are i complia e lth this . '.. ",' '.'" .
BuilderIDesigner
Date ~ UtJ fL, ()(p
in \' - ,
,\ ,:
j I . a
. . ,I
(C:~;.::> / <~{;~/!
" ... ~"-" " -\:>yo
~~'> r;_;~. \,',~ ',,;j'"
",,~., c' ..
,,~,;:;,;,'::;.,,;::-c~,;'::"
REScheck Inspection Checklist
New York State Energy Conservation Construction Code
REScheckSoftware Version 3.5 Release Ie
DA TE: 03/16/06
PROJECT TITLE: Zinger project
Bldg.
Dept.
Vse
Ceilings:
] 1. Ceiling I: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation
Comments:
2. Ceiling 2: Cathedral Ceiling (no attic), R-19.0 cavity insulation
Comments:
Above-Grade Walls:
[] 1. Wall I: Wood Frame, 16" O.c., R-19.0 cavity insulation
Comments:
Windows:
[] 1. Window I: Wood Frame:Double Pane with Low-E, V-factor: 0.320
For windows without labeled V-factors, describe features:
# Panes_Frame Type Thermal Break? [ ] Yes [ ] No
Comments:
-I
I
I
I
I
I
I
I
[ ] I
I
I
[ ] I
[ ] I
[ ] I
Skylights:
1. Skylight I: Wood Frame:Double Pane with Low-E, V-factor: 0.420
For skylights without labeled V-factors, describe features:
# Panes_Frame Type Thermal Break? [ ] Yes [ ] No
Comments:
Floors:
1. Floor I: All-Wood JoistlTruss:Over Vnconditioned Space, R-30.0 cavity insulation
Comments:
Heating and Cooling Equipment:
I. Furnace I: Forced Hot Air, 78 AFVE or higher
Make and Model Number
2. Air Conditioner I: Electric Central Air, 10 SEER or higher
Make and Model Number
-Ail Lt;:;ilkA~e. ----- ----
Joints, penetrations, and all other such openings in the building envelope that are sources of air
leakage must be sealed.
Recessed lights must be I) Type IC rated, or 2) installed inside an appropriate air-tight assembly
with a 0.5" clearance from combustible materials. If non-Ie rated, the fixture must be installed with a
3" clearance from insulation.
Vapor Retarder:
Required on the warm-in-winter side of all non-vented framed ceilings, walls, and floors.
Materials Identification:
Materials and equipment must be installed in accordance with the manufacturer's installation instructions.
Materials and equipment must be identified so that compliance can be determined.
Manufacturer manuals for all installed heating and cooling equipment and service water heating
equipment must be provided.
Insulation R-values and glazing V-fuctors must be clearly marked on tbe building plans or specifications.
Duct Insulation:
[] Supply ducts in unconditioned attics or outside tbe building must be insulated to R-8.
[] Return ducts in unconditioned attics or outside tbe building must be insulated to R-4.
[] Supply ducts in unconditioned spaces must be insulated to R-8.
[] Return ducts in unconditioned spaces (except basements) must be insulated to R-2.
Insulation is not required on return ducts in basements.
Duct Construction:
[] All joints, seams, and connections must be securely fastened witb welds, gaskets, mastics
(adbesives), mastic-plus-em bedded-fabric, or tapes. Duct tape is not permitted.
Exception: Continuously welded and locking-type longitudinal joints and seams on ducts
operating at less tban 2 in. w.g. (500 Pa).
] Ducts sball be supported every 10 feet or in accordance witb tbe manufacturer's instructions.
] Cooling ducts with exterior insulation must be covered witb a vapor retarder.
] Air filters are required in the return air system.
] Tbe HV AC system must provide a means for balancing air and water systems.
Temperature Controls:
[] Eacb dwelling unit bas at lesat one tbermostat capable of automatically adjusting tbe space
temperature set point oftbe largest zone.
Electric Systems:
[] Separate electric meters are required for eacb dwelling unit.
Fireplaces:
[ Fireplaces must be installed witb tight fitting non-combustible fireplace doors.
[ Fireplaces must be provided witb a source of combustion air, as required by tbe Fireplace construction
provisions oftbe Building Code of New York State, tbe Residential Code of New York State or
tbe New York City Building Code, as applicahle.
Service Water Heating:
Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the
water heater has an integral heat trap or is part of a circulating system.
] Insulate circulating hot water pipes to the levels in Table I.
Circulating Hot Water Systems:
[] Insulate circulating hot water pipes to the levels in Table I.
Swimming Pools:
[] All beated swimming pools must have an on/off heater switch and require a cover unless over 20%
oftbe heating energy is from non-depletable sources. Pool pumps require a time clock.
Heating and Cooling-l'iping.lDSuIatioo,
BV AC piping conveying fluids above 105 "F or chilled fluids below 55 "F must he insulated to the
levels in Table 2.
Table I:
Minimum Insulation Thickness for Circulating Hot Water Pipes.
Insulation Thickness in Inches by Pipe Sizes
Non-Circulating Runouts Circulating Mains and Runouts
UP to I" Up to 1.2511 1.5" to 2.0" Over 2"
0.5 1.0 1.5 2.0
0.5 0.5 1.0 1.5
0.5 0.5 0.5 1.0
Heated Water
Tern perature ( F)
170-180
140-160
100-130
Table 2: Minimum Insulation Thicknessfor HVAC Pipes.
Fluid Temp. Insulation Thickness in Inches by Pipe Sizes
Piping System Types Range (F) 2" Runouts 1" and Less 1.25" to 2" 2.5" to 4"
Heating Systems
Low Pressure/Temperature
Low Temperature
Steam Condensate (for feed water)
Cooling Systems
Chilled Water, Refrigerant,
and Brine
201-250 1.0 1.5 1.5 2.0
[20-200 0.5 1.0 1.0 1.5
Any 1.0 1.0 1.5 2.0
40-55 0.5 0.5 0.75 1.0
Below 40 1.0 1.0 1.5 1.5
NOTES TO FIELD (Building Department Use Only)
FORM NO.3
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
Town Hall
Southold, N.Y.
BUILDING PERMIT
(THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL
COMPLETION OF THE WORK AUTHORIZED)
PERMIT NO.
32164 Z
Date JUNE
28, 2006
permission is hereby granted to:
JULIANA ZINGER
418 EAST 59TH ST APT 26
NEW YORK,NY 10022
for :
ADDITION & ALTERATIONS TO AN EXISTING SINGLE FAMILY DWELLING AS
APPLIED FOR
at premises located at
1660 INDIAN NECK LA
PECONIC
County Tax Map No. 473889 Section 086
Block 0004
Lot No. 006.001
pursuant to application dated JUNE 22, 2006 and approved by the
Building Inspector to expire on DECEMBER 28, 2007.
Fee $
285.00
Authorized Signature
COpy
Rev. 5/8/02
-".
r
Vlfl.R '2. 3
Permit Number
,
i
--'
REsdteck Compliance Certificate Checked By/Date
New York State Energy Conservation Construction Code
REScheckSoftware Version 3.5 Release Ie
Data filename; C;\Program Files\Check\RESchecklZinger Rescheck.rck
PROJECT TITLE; Zinger project
COUNTY; Suffolk
STATE; New York
HDD; 5750
CONSTRUCTION TYPE; Detached I or 2 Family
HEA TING TYPE; Non-Electric
DA TE; 03/16/06
DATE OF PLANS; 2006
PROJECT DESCRIPTION;
ZingerlRobertson Residence
Indian Neck Lane
Southold , NY
COMPLIANCE; Passes
Maximum UA ~ 206
Your Home UA ~ 180
12.6% Better Than Code (UA)
Ceiling I; Flat Ceiling or Scissor Truss
Ceiling 2; Cathedral Ceiling (no attic)
Skylight I; Wood Frame;Double Pane with Low-E
Wall I; Wood Frame, 16" o.c.
Window I; Wood Frame;Double Pane with Low-E
Floor I; All-Wood Joist/Truss;Over Unconditioned Space
Furnace I; Forced Hot Air, 78 AFUE
Air Conditioner I; Electric Central Air, 10 SEER
Gross Glazing
Area or Cavity Cont. or Door
Perimeter R-Value R- Value U-Factor UA
590 30.0 0.0 21
600 19.0 0.0 30
24 0.420 10
840 19.0 0.0 45
96 0.320 31
1300 30.0 0.0 43
COMPLIANCE STATEMENT; The proposed building represented in this document is consistent with the building plans,
specifications, and other calculations submitted with this permit application. The proposed systems have been designed to meet the
New York State En gy Co e a .on on uction Code requirements. When a Registered Design Professional has stamped and
signed this page, t yare at! tin that the st ofhis/her knowledge, belief, and professional judgment, such plans or
specifications are i complia e tth this
Builderroesigner
Date' W<J fL- o(P
REScheck Inspection Checklist
New York State Energy Conservation Construction Code
REScheckSoftware Version 3.5 Release Ie
DA TE: 03/16/06
PROJECT TITLE: Zinger project
Bldg.
Dept.
Use
Ceilings:
I. Ceiling I: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation
Comments:
2. Ceiling 2: Cathedral Ceiling (no attic), R-19.0 cavity insulation
Comments:
Above-G rade Walls:
[] 1. Wall I: Wood Frame, 16" O.c., R-19.0 cavity insulation
Comments:
Windows:
1. Window I: Wood Frame:Double Pane with Low-E, U-factor: 0.320
For windows without labeled U-factors, describe features:
# Panes_Frame Type Thermal Break? [ ] Yes [ ] No
Comments:
Skylights:
1. Skylight I: Wood Frame:Double Pane with Low-E, U-factor: 0.420
For skylights without labeled U-factors, describe features:
# Panes_ Frame Type Thermal Break? [ ] Yes [ ] No
Comments:
Floors:
[] 1. Floor I: All-Wood Joist/Truss:Over Unconditioned Space, R-30.0 cavity insulation
Comments:
Heating and Cooling Equipment:
I. Furnace I: Forced Hot Air, 78 AFUE or higher
Make and Model Number
2. Air Conditioner I: Electric Central Air, 10 SEER or higher
Make and Model Number
Air Leakage:
Joints, penetrations, and all other such openings in the building envelope that are sources of air
leakage must be sealed.
Recessed lights must be I) Type IC rated, or 2) installed inside an appropriate air-tight assembly
with a 0.5" clearance from combustible materials. Ifnon-IC rated, the fixture must be installed with a
3" clearance from insulation.
Vapor Retarder:
[] Required on the warm-in-winter side of all non-vented framed ceilings, walls, and floors.
Materials Identification:
] Materials and equipment must be installed in accordance with the manufacturer's installation instructions.
] Materials and equipment must be identified so that compliance can be determined.
] Manufacturer manuals for all installed heating and cooling equipment and service water heating
equipment must be provided.
Insulation R-values and glazing V-fuctors must be clearly marked on the building plans or specifications.
Duct Insulation:
[] Supply ducts in unconditioned attics or outside the building must be insulated to R-8.
[] Return ducts in unconditioned attics or outside the building must be insulated to R-4.
[] Supply ducts in unconditioned spaces must be insulated to R-8.
[] Return ducts in unconditioned spaces (except basements) must be insulated to R-2.
Insulation is not required on return ducts in basements.
Duct Construction:
All joints, seams, and connections must be securely fastened with welds, gaskets, mastics
(adhesives), mastic-plus-embedded-fubric, or tapes. Duct tape is not permitted.
Exception: Continuously welded and locking-type longitudinal joints and seams on ducts
operating at less than 2 in. w.g. (500 Pal.
Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions.
Cooling ducts with exterior insulation must be covered with a vapor retarder.
Air filters are required in the return air system.
The HV AC system must provide a means for balancing air and water systems.
Temperature Controls:
Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space
temperature set point of the largest zone.
Electric Systems:
Separate electric meters are required for each dwelling unit.
Fireplaces:
[] Fireplaces must be installed with tight fitting non-combustible fireplace doors.
[] Fireplaces must be provided with a source of combustion air, as required by the Fireplace construction
provisions ofthe Building Code of New York State, the Residential Code of New York State or
the New York City Building Code, as applicable.
Service Water Heating:
Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the
water heater has an integral heat trap or is part of a circulating system.
Insulate circulating hot water pipes to the levels in Table I.
Circulating Hot Water Systems:
Insulate circulating hot water pipes to the levels in Table 1.
Swimming Pools:
All heated swimming pools must have an on/off heater switch and require a cover unless over 20%
ofthe heating energy is from non-depletable sources. Pool pumps require a time clock.
Heating and Cooling Piping Insulation:
HV AC piping conveying fluids above 105 "F or chilled fluids below 55 "F must be insulated to the
levels in Table 2.
Heated Water
Temperature ( F)
170-180
140-160
100-130
.
Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes.
Insulation Thickness in Inches by Pipe Sizes
Non-Circulatin~ Runouts Circulatin~ Mains and Runouts
Up to 1" Up to 1.25" 1.5" to 2.0" Over 2"
0.5 1.0 1.5 2.0
0.5 0.5 1.0 1.5
0.5 0.5 0.5 1.0
Table 2: Minimum Insulation Thicknessfor HVAC Pipes.
Fluid Temp. Insulation Thickness in Inches by Pipe Sizes
Pipin~ System Types Ran~e ( F) 2" Runouts J" and Less 1.25" to 2" 2.5" to 4"
Heating Systems
Low PressurelT em perature
Low Temperature
Steam Condensate (for feed water)
Cooling Systems
Chilled Water, Refrigerant.
and Brine
201-250 1.0 1.5 1.5 2.0
120-200 0.5 1.0 1.0 1.5
Any 1.0 1.0 1.5 2.0
40-55 0.5 0.5 0.75 1.0
Below 40 1.0 1.0 1.5 1.5
NOTES TO FIELD (Building Department Use Only)