HomeMy WebLinkAbout31276-ZFORM NO. 4
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
Office of the Building Inspector
Town Hall
Southold, N.Y.
CERTIFICATE OF OCCUPANCY
No: Z-31863
THIS CERTIFIES that the building ALTERATION
Date: 09/26/06
Location of Property: 575 WEST SHORE DR SOUTHOLD
(HOUSE NO.) (STREET) (HAMLET)
County Tax Map No. 473889 Section 80 Block 1 Lot 44
Subdivision
Filed Map No. Lot No.
conforms substantially to the Application for Building Permit heretofore
filed in this office dated JULY 7, 2005 pursuant to which
Building Permit No. 31276-Z dated JULY 14, 2005
was issued, and conforms to all of the requirements of the applicable
provisions of the law. The occupancy for which this certificate is issued
is CONVERT PORCH TO SUNROOM IN EXISTING SINGLE FAMILY DWELLING AS
The certificate is issued to STEPHEN L. & SUSAN A. CAPOZZOLI
(OWNER)
of the aforesaid building.
SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL N/A
ELECTRICAL CERTIFICATE NO. 2069795 08/21/06
PLUMBERS CERTIFICATION DATED
A hor' ed `ignature
Rev. 1/81
mcl.�T
-------- Form No.6
17
i TOWN OF SOUTHOLD
BUILDING DEPARTMENT
TOWN HALL
SEP 2 2 2 765-1802
i
APPLICA T ION FOR CERTIFICATE OF OCCUPANCY
This application must be filled in by typewriter or ink and submitted to the Building Department with the following:
A. For new building or new use:
1. Final survey of property with accurate location of all buildings, property lines, streets, and unusual natural or
topographic features.
2. Final Approval from Health Dept. of water supply and sewerage -disposal (S-9 form).
3. Approval of electrical installation from Board of Fire Underwriters.
4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead.
5. Commercial building, industrial building, multiple residences and similar buildings and installations, a certificate
of Code Compliance from architect or engineer responsible for the building.
6. Submit Planning Board Approval of completed site plan requirements.
B. For existing buildings (prior to April 9, 1957) non -conforming uses, or buildings and "pre-existing" land uses:
1. Accurate survey of property showing all property lines, streets, building and unusual natural or topographic
features.
2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is
denied, the Building Inspector shall state the reasons therefor in writing to the applicant.
C. Fees
1. Certificate of Occupancy - New dwelling $25.00, Additions to dwelling $25.00, Alterations to dwelling $25.00,
Swimming pool $25.00, Accessory building $25.00, Additions to accessory building $25.00, Businesses $50.00.
2. Certificate of Occupancy on Pre-existing Building - $100.00
3. Copy of Certificate of Occupancy - $.25
4. Updated Certificate of Occupancy - $50.00
5. Temporary Certificate of Occupancy - Residential $15.00, Commercial $15.00
New Construction:
Location of Property:
Old or Pre-existing Building:
f1 _ttf
Street
Owner or Owners of Property:
Date.
(check one)
pazzDl�'
Suffolk County Tax Map No 1000, Section N 7'� Block
Subdivision
Permit No.
Health Dept. Approval:
Planning Board Approval:
Filed Map.
Date of Pennit. Applicant:
Underwriters Approval:
Request for: Temporary Certificate Final Certificate:
Fee Submitted: $
Co 3j8fv36 q �
Lot
Lot
(check one)
0
Applicant Si at
FORM NO. 3
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
Town Hall
Southold, N.Y.
BUILDING PERMIT
(THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL
COMPLETION OF THE WORK AUTHORIZED)
PERMIT NO. 31276 Z Date JULY 14, 2005
Permission is hereby granted to:
LINDA ANN WENK
NEW YORK,NY 10011
for :
ENCLOSE AN EXISTING PORCH (CONVERSION TO SUNROOM) AS APPLIED FOR
at premises located at 575 WEST SHORE DR SOUTHOLD
County Tax Map No. 473889 Section 080 Block 0001 Lot No. 044
pursuant to application dated JULY 7, 2005 and approved by the
Building Inspector to expire on JANUARY 14, 2007.
Fee $ 150.00
ORIGINAL
Rev. 5/8/02
O
rJ�rJ�rJr1rJrJrJrJrJ�rJ�rJ�rJ�rJrJ�rJ�r�rJ�rJ arJ�rJ�cPrPr�c frl: i 7 i I PrPrJrJrJ�rJ�rJ�rJ�rJ�rJ�rJr�r�rJ�rJrlr�r�i PrJ�rJrJ�tPcPrJ��PrJ�rJ�r�rJrJ��Pr�rJrJ�rJ�
�
5
�D
5
BY THIS CERTIFICATE OF COMPLIANCE THE
5
NEW YORK BOARD OF FIRE UNDERWRITERS
5
5
BUREAU OF ELECTRICITY
S
1
40 FULTON STREET ^ NEW YORK, NY 10038 r
5
f C CERTIFIES THAT
5
51
Upon the application of upon premises owned by
5
5
5
BRIAN BROOKS ELEC. INC. STEVEN & SUSAN CAPOZOLLIBOX
�S
1001, 455 BEEBE 1OE RD.
5
CUTCHOGUE, NY 119 5, SOUTHOLD NY 11971
Located at OAK DR. & WEST SHORE RD. SOUTHOLD, NY 11971
S
Application Number: 2069795 Certificate Number: 2069795
5
c5
Section: Block: Lot: Building Permit: 31276Z BDC: ns11
C55
Residential 0-599 square ft.
Described as a 4 occupancy, wherein the premises electrical system consisting of
rcj
5
electrical devices and wiring, described below, located in/on the premises at:
SFirst
Floor, Outside,
5
A inspection the limited to devices to the detailed
visual of premises electrical system, electrical and wiring extent
herein, was conducted in accordance with the requirements of the applicable code and/or standard
5
5
promulgated by the State of New York, Department of State Code Enforcement and Administration, or other
having found to be in therewith the 21st Day August, 2006.
5
5
authority jurisdiction, and compliance on of
Name OTY Rate Ratin Circui[ Type
C
5
5
5
Wiring and Devices
Outlet l 0 Fixture
5
5
5
Fixture 1 0 Incandescent
5
Outlet 4 0 General Purpose
Receptacle 3 0 General Purpose
r�
5
Cj
5
Paddle Fan 1 0
Receptacle l 0 GFCI
rj
5
S
S
5
5
5
seal
5
I of 1
5
5
5
This certificate may not be altered in any way and is validated only by the presence of a raised seal at the location indicated.
5
S
.31L7�
TOWN OF SOUTHOLD BUILDING DEPT.
76S-1802
INSPECTION
[ ] FOUNDATION 1 ST [ ] ROUGH PLBG.
[ ] FOUNDATION 2ND [ ]IN LATION
[ ]
FRAMING/ STRAPPING [ FINAL
[ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION
DATE ?IIIL6)T INSPECTOR
TOWN OF SOUTHOLD BUILDING DEPT.
765.1802
INSPECTION
[ ] FOUNDATION IST
[ ] FOUNDATION 2ND
[ ] ROUGH PLBG.
[ ] INSULATION
[ ] FRAMING / STRAPPING [ L]-FfN- AL
[ ] FIREPLACE A CHIMNEY [ ] FIRE SAFETY INSPECTION
DATE INSPECTOR
765.1802
BUILDING DEPT.
INSPECTION
[ ] FOUNDATION 1ST[ O PLBG-
FOUNDATION 2ND [ ] RNSULATION
[ ] FRAMING [ ] FINAL
[ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION
REMARKS: _p
DATE INSPECTOR
/�-7 Ce
765.1802
BUILDING DEPT.
INSPECTION
[ ] FOUNDATION IST
[ ] FO ATION 2ND
[ RAMING
[ ] ROUGH PLBG.
[ ] INSULATION
[ ] FINAL
[ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION
REMARKS:
DATE ` �� INSPECTOR
765.1802
BUILDING DEPT.
INSPECTION
FOUNDATION IST [ ] ROUGH PLBG.
[ ] FOUNDATION 2ND [ ] INSULATION
[ ] FRAMING
[ ] FINAL
[ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION
REMARKS:
� � V
7,
DATE �� ��
INSPECTOR
312-76 z
765-1802
BUILDING DEPT.
INSPECTION
[FOUNDATION IST [
[ ] FOUNDATION 2ND [
[ ] FRAMING [
[ ] FIREPLACE & CHIMNEY [
REMARKS:
] ROUGH PLBG.
] INSULATION
] FINAL
] FIRE SAFETY INSPECTION
C>
DATE 1�1 ®� INSPECTOR
5
FIELD INSPECTION REPORT ' DATE COMMENTS
FOUNDATION (IST)--------------------------------------
- -- -
FOUNDATION (2ND) - - - -
FINAL
J
ADDITIONAL COMMENTS
N
=i i
_ _ m
T
r
FIELD INSPECTION REPORT ' DATE COMMENTS
FOUNDATION (IST)--------------------------------------
- -- -
FOUNDATION (2ND) - - - -
FINAL
J
ADDITIONAL COMMENTS
N
=i i
_ _ m
T
TOWN OF SOUTHOLD PROPERTY RECORD CARD
OWNER
STREET 6-7
VILLAGE
DISTRICT
SUB.
LOT w E-
r Is
e p W L.i
Z
ck n
Ir '_
2/
�'
FORMEk OWNER
N
E
ACREAGE
rzj _4
kap./ y. 4IP,
u/e4
>41tca
S
W
TYPE OF BUILDING
�j �C L
:ES. 216
SEAS.
VL.
FARM
COMM.
IND.
CB.
MISC.
Est. Mkt. Value
LAND
IMP.
TOTAL
DATE
REMARKS
%9 �d
Z A
9
trr�
O -a
3 7
fes./ arrfr -9a T'
4L! ✓
-7"-�• i�.WP/ J ozaeL
AGE
BUILDING CONDITION
U) ^
QY Y
a n
NEW
NORMAL
BELOW
ABOV
FRONTAGE ON WAT
Gi
demoU}ian aP rC mut
clmsly�C-T waaduR.r
Farm
Acre
Value Per Acre
Value
FRONTAGE ON ROA
'illable 1
BULKHEAD
illable 2
DOCK
illable 3
✓oodland
wompland
rush land
louse Plot
otal
Bldg.p0
1 2-2 x
Foundation
Bath
;tension
Basement(
Floors
z
,.tension
Ext. Walls
'
-7i d I v
Interior Finish
A ✓P4
tension
Fire Place
`
Heat
F 14 4
_
ie
Porch
Roof Type
Porch
Rooms 1 st Floor
•eezeway
Patio
Rooms 2nd Floor
3rage
Z 2/ 6
l�
Driveway
Dormer
TOWN OF SOUTHOLD
BUILDING DE"ART.MENT
TOWN HALL f
BUILDING PERMIT APPLICATION CHECKLIST
SOUTHOLD, NY 11971
TEL: (631) 765-1802
FAX: (631) 765-9502
www. northfork.net/Southold/ PERMIT NO.31—,;2
Examined M/, 20
Approved l 20
Disapproved a/c
Expiration , 20_?V-
-720
L---.
Do you have or need the following, before applying?
Board of Health
4 sets of Building Plans_
Planning Board approval
Survey
Septic
N.Y.S
Contact:
Mail
DN FOR BUILDING PERMIT
Date �-?i�_ � � , 20 i75
INSTRUCTIONS
a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4
sets of plans, accurate plot plan to scale. Fee according to schedule.
b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or
areas, and waterways.
c. The work covered by this application may not be commenced before issuance of Building Permit.
d. Upon approval of this application, the Building Inspector will issue a Building Permit to the applicant. Such a permit
shall be kept on the premises available for inspection throughout the work.
e. No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector
issues a Certificate of Occupancy.
f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of
issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the
property have been enacted in the interim, the Building Inspector may authorize, in writing, the extension of the permit for an
addition six months. Thereafter, a new permit shall be required.
APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the
Building Zone Ordinance of the Town of Southold, Suffolk County, New York, and other applicable Laws, Ordinances or
Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The
applicant agrees to comply with all applicable laws, ordinances, building code, housing code, and regulations, and to admit
authorized inspectors on premises and in building for necessary inspections.
(Signature of applicant or name, if a corporation)
(MailiAg address of applicant)
State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder
Name of owner of premises
(As on the tax roll or latest deed)
If applicant is a corporation, signature of duly authorized officer
(Name and title of corporate officer)
Builders License No.
Plumbers License No.
Electricians License No.
Other Trade's License No
land qn which
House Number Street
County Tax Map No. 1000
Subdivision
(Name)
done:
Hamlet
Section!2�O Block Lot
Filed Map No Lot
2. State existing use and occupancy of premi es and mtentlqd u e and
a. Existing use and occupancy
b. Intended use and occunancv C -IP
of proposed construction:
3. Nature of work (check which applicable): New Building Addition Alteration
Repair Removal -Demolition -Other Work
4. Estimated Cost ,Qg Qco Fee
(To be paid on filing this application)
Number of dwelling units on each floor
(Description)
5. If dwelling, number of dwelling units
If garage, number of cars
6. If business, commercial or mixed occupancy, specify nature and extent of each type of use.
7. Dimensions of exilsting structures, if any: Front X f " Rear `.D I , Depth '/h fF —0/1
Height as -D It Number of Stories ' 2
Dimension of same structure with alterations or additions: Front o D Rear
Depth l f It Height `-p `' Number of Stories / z
8. Dimensions of entire new construction: Front Rear Depth
Height Number of Stories
l tr u� f
9. Size of lot: Front q 9 G% �t
Rear � —✓ Depth
10. Date of Purchase Name of Former Owner
11. Zone or use district in which premises are situated L—) —
12. Does proposed construction violate any zoning law, ordinance or regulation? YES_ NO_
13. Will lot be re -graded? YES_ NO�Will excess fill be removed from premises? YES
14. Names of Owner o
Name of Architect
Name of Contractor Address
NO,K_
No.&Y • %6S -a 3
No 1(;,'C/
No.
15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO
* IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY BFB REQUIRED.
b. Is this property within 300 feet of a tidal wetland? * YES N( x
* IF YES, D.E.C. PERMITS MAY BE REQUIRED.
16. Provide survey, to scale, with accurate foundation plan and distances to property lines.
17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey.
STATE OF NEW YORK)
SS:
COUNTY OF f�
-10SJn la'rL;01DQCCk being duly sworn, deposes and says that (s)he is the applicant
(Name of individual signing contract) above named,
(S)He is the
(Contractor, Agent, Corporate Otficer, etc.)
of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;
that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be
performed in the manner set forth in the application filed therewith.
Sw to before me this'
day ofJ,,L 20 \S
Notary Pub .
MELANIE DOROSKI
NOTARY PUBLIC, State of Now Wk
No. 01D04634870
Oualified in Suffolk Courtly
Commission Expires September 0,
BUILDING PERMIT EXAMINER CHECKLIST
DATE REVIEWED: _&,3/05.
APPLICANT: _ 5' ) DATE SUBMITTED: 6/ /OS
SCTM# DISTRICT: 1,000, SECTION:, BLOCK: J_, LOT: SUBDIVISION: A rrx
ADDRESS: 5)'-�r zd, MRole0 CITY: 4"P 01, ZONING DISTRICT: CONFORMING?
BUILDING PERMITS OPEN/EXPIRED: PRE CO: Y O - BP -Z / C/0 Z- , INFO
BP -Z / C/0 Z- , INFO BP -Z / C/0 Z- , INFO
SINGLE & SEPARATE CERTIFICATION -REQUIRED TES:
LOTS 40,000SF -100-24. Lot recognition. (CREATED before June 30, 1983), UNDERSIZED LOTS FROM JAN.1997 100-25. Merger.(A nonconforming at any time aft r 7/1/8.
REQ. LOT SIZE: ACT. LOT SIZE: Q. LOT COV. ACT. LOT COV. _.
REQ. FRONT tS PROP. FRONT jREQ SIDE j a Z_,SACT. SIDE
REQ. REAR PROP. REAR / REQ.,fIEIGHT PROP. HEIGHT
PROJECT DESCRIPTION:
ESTIMATED PROJECT COST: 4 Z,,)( C CT/ENGINEER:,
WATERFRONT? If 19 DESCRIPTION:
BULKHEAD? -_�- ----- DISTANCE?
PANEL #
APPROVALS REQUIRED
SUFFOLK COUNTY HEALTH DEPT: YES or OO (BED ft DTE:
TOWN SEPTIC RECEIPT: Yo�N EPTIC CERTIFICATION: Y O1g:
FLOOD ZONED_
PERMIT #:
NEW YORK STATE DEC: PRE -DEC 9/1/75 YES O .0 DTE: / / PERMIT #;
SOUTHOLD TOWN TRUSTEES: YES o 3�0 DTE / / PERMIT # _
TOWN ZONING BOARD APPROVAL: YES o k O� DTE: // PERMIT #:
TOWN PLAN. BOARD APPROVAL: YES or O_ DTE /_/_ PERMIT #:
TOWN HISTORICAL PRE (SPLIA): YES or O
NEW YORK STATE CODE COMPLIANCE (SEE PAGE 2(:-YEy or NO
NOTES
FEE STRUCTURE: FOUNDATION:
SF
FIRST FLOOR:
SF
SECOND FLOOR:
SF
OTHER:
SF INIT
TOTAL:
SF FEE
L. ( SF)- (SF)= SFX $ =$
Z. ( SF)- (SF)=.
SFX$ =$
3.( SF)- ( SF)= SFX $
OTHER TOTAL
FEE FEE
FINAL TOT
NEW YORK STATE CODE COMPLIANCE CHECKLIST
CLIMATIC/GEOGRAPHIC DESIGN CRITERIA:
Ground Snow Load: 45 Wind Speed: 120MPH Seismic Design Category: B
Weathering: Severe Frost Depth: 36". Termite: M -H Decay: S -M
Design Temp: 11 Ice Shield Underlay: YES Flood Hazards:
USE/OCCUPANCY CLASSIFICATION:
HEIGHT/FIRE AREA:
TYPE OF CONSTRUCTION:
DESIGN CRITERIA: ENGINEERED/PRESCRIPTIVE
FULL FRAMING DESIGN ELEMENTS: Y/N
HEADERS: Y/N WALL STUDS: Y/N GIRDERS: Y/N
CEILING JOISTS: Y/N FLOOR JOISTS: Y/N ROOF RAFTERS: Y/N
LUMBER SPECIES AND GRADE: Y/N
DESIGN LOAD CALCULATIONS: Y/N
LIVE: Y/N DEAD: Y/N SNOW: Y/N SEISMIC: Y/N WIND: Y/N
WINDOW AND DOOR SCHEDULE:
MISSLE TEST REQUIREMENTS: Y/N
EGRESS 5.7-S.F.: Y/N
LIGHT 8%: Y/N
VENT 4%: Y/N
NAILING/CONSTRUCTION SCHEDULE: Y/N
MEANS OF EGRESS: Y/N
PLUMBING RISER DIAGRAM: Y/N
LOCATION OF FIRE PROTECTION EQUIPMENT: Y/N
TRUSS DESIGN: Y/N
CERTIFICATION: Y/N
ENERGY CALLS: Y/N
TOTAL COMPLIENCE? Y/N (RETURN TO PAGE ONE)
SITE SURVEY
MAP OF REYDON SHORES
SITUATE AT BAYVIEW
TOWN OF SOUTHOLD
SUFFOLK COUNTY, N.Y.
S.C. TAX No. 1000-80-1-44
SCALE: 1 " = 20'
JANUARY 3, 2000
AREA = 11,460 SQ. RT.
0263 AC
ELEVATIONS REFER TO APPROX MSL. DATUM
AND ARE THE RESULT OF ACTUAL FIELD MEASUREMENTS
SOUTHOLD BAY WITHIN 300. OF PROPERTY
PROPERTY LOCATED IN FLOOD ZONE X
AS SHOWN ON THE FLOOD INSURANCE RATE MAP
MAP NO. 36105CO167 G
EFFECTIVE DATE MAY 4, 1998
INFCRMATI ON TAKEN FIR CS SURVEY
LAND SURVEYOR DATED MAY 6. 2004
CERTIFIED TO:
STEVEN CAPOZZOLI
SUSAN CAPOZZOLI
JOB NO. 2003-528
FILED: JULY 2, 1931
REVISIONS:
REV. PROP. DWELT_ 5/6/04
REV. SCALE 5/6/04
K
4,_
Y
U
0
i
R
MI
_ zo.
SITE PLAN
GENERAL NOTES:
1. ALL WORK SHALL COMPLY WITH FEDERAL, STATE, AND LOCAL BUILDING CODES
AND ORDINANCES
2 BEFORE COMMENCEMENT OF WORK, THE CONTRACTORS SHALL FURNISH THE
OWNER AND ARCHITECT WITH COPIES OF ALL REQUIRED INSURANCE AND
WORKER'S COMPENSATION CERTIFICATES AND NAMES OF ALL SUBCONTRACTORS.
3 THE CONTRACTORS SHALL BE RESPONSIBLE FOR ALL DIMENSIONS AND
CONDITIONS ON THE JOB. THE ARCHITECT MUST BE NOTIFIED OF ANY VARIATIONS
FROM THE DIMENSIONS SHOWN.
4 THE CONTRACTOR SHALL SUPPLY ALL LABOR AND MATERIAL SHOWN ON THE
DRAWINGS UNLESS OTHERWISE NOTED
5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ADEQUATELY BRACING AND
PROTECTING ALL WORK DURING CONSTRUCTION AGAINST DAMAGE, BREAKAGE,
COLLAPSE, DISTORTION, AND MISALIGNMENT ACCORDING TO ALL APPLICABLE
CODES
6. THE CONTRACTOR SHALL PAY FOR AL PERMITS, FEES. AND COSTS RELATED TO
THE WORK OF THIS CONTRACT. CONTRACTORS SHALL INITIATE ALL REQUIRED
INSPECTIONS OF ALL WORK COMPLETED UNDER THIS CONTRACT.
7 THE CONTRACTOR SHALL AT ALL TIMES KEEP THE PREMISES CLEAN AND IS
RESPONSIBLE FOR REMOVAL OF ALL RUBBISH FOR ALL TRADES FROM THE JOB SITE
B. ANY "EXTRAS" FOR ALL OR LEGITIMATE UNFORESEEN CONDITIONS SHALL BE
DOCUMENTED WITH THE COST OF APPROVAL BY OWNER OR HIS AGENT PRIOR TO
STARTING ADDITIONAL WORK
9 DOUBLE_ JOISTS ARE TO BE INSTALLED UNDER ALL WALL PARTITIONS RUNNING
PARALLEL TO THE FRAMING PROVIDE DOUBLE HEADER JOISTS AT ALL OPENINGS
REFER TO CONSTRUCT DRAWINGS FOR SIZES.
10. ALL FRAMING LUMBER TO BE DOUGLAS FIR #2 CONS. GRADE OR BETTER
11 THE CONTRACTOR SHALL PROVIDE SHOP DRAWINGS FOR ALL SPECIAL WORK
SUCH AS BUT NOT LIMITED TO: MILLWORK, SPRINKLER SYSTEMS AND STEEL WORK
ALL SHOP DRAWINGS NEED THE APPROVAL OF THE ARCHITECT BEFORE
PROCEEDING
ELECTRICAL LEGEND:
NOTE ALL ELECTRICAL WORK TO BE IN ACCORDANCE WITH THE RULES AND
REGULATIONS OF THE N.Y B.F.U. AND A CERTIFICATE FROM THE N Y B F U. IS TO
BE PRESENTED TO THE OWNER AT THE COMPLETION OF THE JOB
NOTE THE OWNER SHALL PROVIDE ALL LIGHTING FIXTURES UNLESS OTHERWISE
NOTED ALL OTHER ELECTRICAL EQUIPMENT AND MAT'L TO BE SUPPLIED BY THE
ELECTRICAL CONTRACTOR.
NOTE- ALL SWITCHES AND RECEPTACLES TO BE 'LUTRON', "DECORA" IN COLOR
O.N.O. DOWNLIGHT TRIMS TO BE WHITE
4)
DUPLEX ELECTRICAL RECEPTACLE
$
WALL SWITCH
TWO COATS FINISH (COLORS T B.O. BY OWNER) SATIN FIN THROUGHOUT
3 -WAV WALL SWI CCH
HARDWOOD FLOORING -SELECT #1 RED OAK 2 1/4W. 15LB FEL L.UNDERLAYMENT
® (3 FINISH COATS OF CLEAR SATIN POLYURETHANE)
y$3
�db
WALL MOUNTED JUNCTION BOX
�E
EXTERIOR MOUN TED DOWNLIGHT (100W)
OF
EXT MOUNTED LIGHT WITH FAN
-I(
QST
NEW STRUCTURED CABLE
CONSTRUCTION LEGEND:
1ST FLOOR EXTERIOR DOORS
NEW EXTERIOR PARTITION- 2" X 6" WOOD STUD WALL W/ 1/2" CDX PLYWD
EXTERIOR SHEATHING (TYVEK WRAPPED & TAPED), QUALITY EDGE SIDING
BY "TRU-SHAKE" - COLOR WICKER APP. EQ PROV 1/2" GYP. BD.(SCREWED /TAPED)
CLR PINE 5" COLONIAL BASE TRIM, & R-21 FOIL FACE INSUL. (HIGH DENSITY).
31/2" WIDE CLEAR PINE COLONIAL TRIM ON ALL WINDOWS & DOORS
ALL WINDOWS TO HAVE STOOL
NEW INTERIOR PARTITION -2" X 4" WOOD STUD WALL WITH 1/2" GYP. BD
= (SCREWED/TAPED) APPLIED BOTH SIDES NOTEPROVIDE MOISTURE
RESIST GYP, BD (GREEN BD) FOR ALL BATHROOM WALL AND CEILINGS
PROV CEMENT WALL BD FOR ALL TILE AREAS.
INTERIOR PAINT- TO BE "BENJAMIN MOORE" U.O.N ONE COAT PRIMER AND
TWO COATS FINISH (COLORS T B.O. BY OWNER) SATIN FIN THROUGHOUT
U ON ALL TRIM SEMI -GLOSS
HARDWOOD FLOORING -SELECT #1 RED OAK 2 1/4W. 15LB FEL L.UNDERLAYMENT
® (3 FINISH COATS OF CLEAR SATIN POLYURETHANE)
SUB -FLOOR -USE 3/4" THICK PLYWOOD GLUED AND NAILED
SUB FOR TILE AREAS TO BE SCREWED AND GLUED
CERAMIC TILE - "AMERICAN OLEAN" TILE OR APP EQ TILE TO BE INSTALLED
® OVER 1/2" CEMENT BOARD U O N WALL AND FLOOR GROUT TO HAVE
WATERPROOF ADDITIVE MIXED IN.
INSULATION NOTES:
- EXISTING EXTERIOR WALLS. 2"X4" WOOD STUD R-15 HIGH DENSITY INSULATION
BY'CERTANTIEED' OR APPROVAL EQUAL
- NEW EXTERIOR WALLS: 2"X6" WOOD STUD R-21 FOIL FA HIGH DENSITY INSULATION
BY CERTAINTEED' OR APPROVED EQUAL
- NEW ROOF R-38 KRAFT -FA INSULATION BY CERTAINTEED' OR APPROVED EQ
- NEW FLOORS: R-38 KRAFT -FA INSULATION BY'CERTAINTEED' OR APPROVED EQ.
DOOR SCHEDULE:
1ST FLOOR EXTERIOR DOORS
DOOR ID
WIDTH
I HEIGHT
NDOAATTO RIAL
I OPERATION
LOCATION
QO]
U -B"
GLASS
RIGHT SWIPIG
PORCH
WINDOW LEGEND:
ALL WINDOWS TO BE ANDERSEN
VINYL CLAD 400 SERIES,
PROV SNAP -IN GRILLS ON INSIDE ONLY
WINDOW SPECS
R NUMBERS WIDTH I OPENING ROUGH QTtl
(A) I TW 26410-2W I V-41/4" 1 5'-07/8" 1 1
I CB) I TW 26410-3W 1 8'-01/2" 1 5'-07/8" 1 1
2'-1
FIRST FLOOR PLAN
BELOW GRADE
LVL BEAM
m
Z
0
DU)
U)
Z
m
0
a
AP�PQ,ED AS NOTED
DATE:B.P. #
FEE: 5Z% BY: L ]`—
NOTIFY BUILDING DEPARTMENT AT FLOOD
765-1802 8 AM TO 4 PM FOR THE
FOLLOWING INSPECTIONS: -11. 11
2. ROUGH-- TRAMINT-9-PEOMBING—"-
3. INSULATION
4. FINAL - CONSTRUCTION MUST
BE COMPLETE FOR CO.
ALL CONSTRUCTION SHALL MEET THE
REQUIREMENTS OF THE CODES OF NEW
YORK STATE. NOT RESPONSIBLE FOR
DESIGN OR CONSTRUCTION ERRORS.
COMPLY WITH ALL CODES OF
NEW YORK STATE & TOWN CODES
AS REO IRED AND CONDITIONS OF
SOUTHOLD TOWN ZBA
SOUTHOLD TOWN PLANNING BOARD
SOUTHOLD TOWN TRUSTEES
N.Y.S. DEC
OCCUPANCY OR
USE IS UNLAWFUL
WITHOUT CERTIFICATE
OF OCCUPANCY
UNDERWRRERS CERVIGAIE
REQUIRED
FOUNDATION/FRAMING PLAN
ROOF FRAMING PLAN
0,1
IN CODE.
ATION OF
SHAH.
Lm
THESE DRAWINGS AS INSTRUMENTS OF SERVICE.
ARE THE SOLE PROPERTY OF THE ARCHITECT
NO REVISIONS, CHANGES. AND/OR MODIFICATIONS
SHALL BE ALLOWED WITHOUT WRfREN AUTHORIZATION
BY THE ARCHITECT ANY REPRODUCTION IN PART
OR WHOI I? IS STRICTLY PROHIBITED BY LAW
W
U
Z
W
Q
U)
cc Yi
O
N
N
O
a.
Q
U
Mx
LL
0
}
w
z
0
O
0
N
h
N
O
O
N
QO]
O
'
IQ
c
v
ui
r
1 /4" =1'0"
PROPOSED
FLOOR PLANS
A.1
WEST ELEVATION
SOUTH ELEVATION-SK2
EAST ELEVATION
NORTH ELEVATION
THESE DRAWINGS AS INSTRUMENTS OF SERVICE.
ARE THE SOLE PROPERTY OF THE ARCHITECT
NO REVISION$, CHANGES. AND/OR MODIFICATIONS
SHALL BE ALLOWED WITHOUT WRITTEN AUTHORIZATION
BYTHEARCHITECi ANYREPRODUCTIDN INPART
OR WHOLE IS STRICTLY PROHIBITED BY LAW
W 5
v
O � N
z
a
�a
tj
z�
N
E`^
U
All
a�
a
M
i
W
U�
Y
Z°
WW
C)
z
U)
W
cc
J
0
N
No
Oo
C�
Q
o
U
w
0
0
J
m
w
H
0
H
o�w
�
�
N
O
N
r�
�?
r
0
0
0
0
0
0
0
0
z
w
z
w
z
W
z
W
J
U
J
U
J
U
J
U
0
I -z
O
Fp❑-
0
Hz
O
F -z
13
W w
L,'
Lcul Oj
N�
NW
iL
fl)
NQ
on N ¢
LoN¢ a:
W
uJw
O
O
O
N
SCALE.
A"=-I'l
DWG NAME:
PROPOSED
ELEVATIONS
DWG. NO..
A.2
FASTEST MILE WINDSPEED (MPH)
PRESCRIPTIVE DESIGN TABLE 3 2 (AMERICAN FOREST & PAPER ASSOCIATION
U - CONNECTOR UPLIFT LOAD.
L - CONNECTOR LATERAL LOAD (PERPENDICULAR TO THE WALL)
B - CONNECTOR SHEAR LOAD (PERALLEL TO THE WALL)
-ANCHORAGE REQUIRED TO RESIST LATERAL LOADS SHALL BE DETERMINED IN THE FOUNDATION DESIGN PER SECTION 1.1 4
TABULATED UPLIFT REQUIREMENTS ASSUME A ROOF/CEILING DEAD LOAD OF 10 PSF(2/3 X 15 PSF)
TABULATED UPLIFT AND LATERAL CONNECTION REQUIREMENTS SHALL BE PERMITTED TO BE MULTIPLIED BY 0 70 AND 0.85, RESPECTIVELY, FOR FRAMING NOT
LOCATED WITHIN 8 FEET OF BUILDING CORNERS,
8D NALSE PACED 6CAT PER METER EDGES AND 52UAT INTERMEDIATE TR SUPPORTS) FOR OTHER WALL SHEAR CAPACITIES WALLS SHEATHING WITH ITHE REQUIRED SHEARTWITH
CAPACITY OF 421 FILECAPACITY OF THE
CONNECTION SHALL BE INCREASED.
FASTEST MILE WINDSPEED (MPH)
90
100
110
t20
90
100
110
U
L
5
U
L
S
U
L
S
U
L
S
CONNECTION.
NUMBER
ROISPAN
RAFTER/TRUSS
ROOF SPAN
LEEWARD
N/INDWAR
LEEWARD
END
INTERIOR
- ---
8
3
3
3
---'
-
10
OF
')
REQUIRED CAPACITY OF CONNECTION (LBS) °�
(FT)
STORIES
10D BOX NAILS SHALL BE PERMITTED TO BE SUBSTITUTED FOR BD COMMON NAILS
' WHEN CEILING JOISTS ARE INSTALLED PARALLEL TO RAFTERS, THE SUM OF THE TOE NAILS IN THE RAFTER AND CEILING JOIST SHALL EQUAL
OR EXCEED THE TABULATED NUMBER OF NAILS REQUIRED
12
193
20
58
-
681
264
-
681
206%.A.
427
681
291
----
23 7
681
2
-11 .9
24
89
-274
-15,6
325
-12 1
-411
260
17
BLOCKING TO SILL OR TOP PLATE (TOE -NAILED)
358
20
282
SILL PLATE TO
3-16D
386
19
JOIST ON LEDGER TO BEAM (TOE -NAILED)
500
386
20
626
314
PER JOIST --
i6
426
327
PER FOOT
FOUNDATION
2
28
119
580
DIAGONAL BOARD SHEATHING
726
1" X 6" OR i" X W
2-8D
28
371
t" X 10" OR WIDER
3-81)
(CRAWL SPACE OR
24
32
149
7"EDGE/ 10"FIELD
A
447
BD
.A.
366
32
416
4133
\\
570
BASEMENT)
3" EDGE/ 6" FIELD
740
25/32"
BD
927
509
75
NIL
73 f
422
27
GYPSUM WALLBOARD
561
7" EDGE/ 10" FIELD
28
HARDBOARD
BD
36
179
PARTICLEBOARD PANELS
BD
(SEE TABLE 3 9)
30
36
461
4"= T ,0„
DWG, NAME:
632
2-8D
PER SUPPORT
620
T' X 10" OR WIDF_R
3 -BD
58
43
421
128
76
421
206
13
421
291
254
421
WALL BOTTOM
LOCATED WITHIN 6 FEET OF BUILDING CORNERS
LOADS ARE SPECIFIED FOR ROOF -TO -WALL CONNECTIONS WHEN CALCULATING UPLIFT LOADS FOR WALL-TO-WALL OR WALL -TO -FOUNDATION
ABOVE,
24
28
89
CONNECTIONS. TABULATED UPLIFT VALUES
' LENGTH REQUIREMENTS ASSUME A MEAN ROOF HEIGHT OF 33 FEET. FOR MEAN ROOF HEIGHTS OF 15 FEET OR LESS, THE TABULATED VALUES SHALL BE
TABULATED
PERMITTED TO BE MULTIPLIED BY 0.80.
170
2_SD
PER SUPPORT
260
1" X 10" OR WIDER
3-8D
358
' NAILING REQUIREMENTS ARE BASED ON WALL SHEATHING NAILED 6" ON -CENTER AT THE PANELEDGE
IF WALL SHEATHING IS NAILED 3" ON -CENTER AT EHT PANEL EDGE
TO OBTAIN HIGHER SHEAR CAPACITIES, NAILING REQUIREMENTS FOR STRUCTURE MEMERS SHALL BE
DOUBLED, OR ALTERNATE CONNECTORS, SUCH AS SHEAR PLATES,
SHALL BE USED TO MAINTAIN THE LOAD PATH
2 WHEN WALL SHEATHING IS CONTINUOUS OVER CONNECTED MEMBERS, THE TABULATED NUMBER OF j
NAILS SHALL BE PERMITTED TO BE REDUCED TO 1-16D NAIL PER llll
FOOT
PLATE TO
FOUNDATION
119,
211
314
426
2
32
36
149
N.
253
N
,
368
N
,
493
(SLAB -ON -GRADE)
422
581
179
294
_---�
U - CONNECTOR UPLIFT LOAD.
L - CONNECTOR LATERAL LOAD (PERPENDICULAR TO THE WALL)
B - CONNECTOR SHEAR LOAD (PERALLEL TO THE WALL)
-ANCHORAGE REQUIRED TO RESIST LATERAL LOADS SHALL BE DETERMINED IN THE FOUNDATION DESIGN PER SECTION 1.1 4
TABULATED UPLIFT REQUIREMENTS ASSUME A ROOF/CEILING DEAD LOAD OF 10 PSF(2/3 X 15 PSF)
TABULATED UPLIFT AND LATERAL CONNECTION REQUIREMENTS SHALL BE PERMITTED TO BE MULTIPLIED BY 0 70 AND 0.85, RESPECTIVELY, FOR FRAMING NOT
LOCATED WITHIN 8 FEET OF BUILDING CORNERS,
8D NALSE PACED 6CAT PER METER EDGES AND 52UAT INTERMEDIATE TR SUPPORTS) FOR OTHER WALL SHEAR CAPACITIES WALLS SHEATHING WITH ITHE REQUIRED SHEARTWITH
CAPACITY OF 421 FILECAPACITY OF THE
CONNECTION SHALL BE INCREASED.
FASTEST MILE WINDSPEED (MPH)
AMERICAN FOREST AND PAPER ASSOCIATION (AF&PA)
WOOD FRAME CONSTRUCTION
PRESCRIPTIVE DESIGN TABLE 3.3 (AMERICAN FOREST & PAPER ASSOCIATION
I _
REF. TABLE 1609.6.2.1 (1)
X t 53
90
100
110
120
HORIZONTAL LOADS VERTICAL LOADS____
38.3
U,
WIND LOAD ROOF
S
IJ`
LJ
S
4
90
100
U'
L'
S
RAFTER/TRUSS
ROOF SPAN
LEEWARD
N/INDWAR
LEEWARD
END
INTERIOR
- ---
8
3
3
3
---'
2-16D
10
---
ROOF
SPACING (IN)
(FT)
REQUIRED CAPACITY OF CONNECTION (LBS)1"
10D BOX NAILS SHALL BE PERMITTED TO BE SUBSTITUTED FOR BD COMMON NAILS
' WHEN CEILING JOISTS ARE INSTALLED PARALLEL TO RAFTERS, THE SUM OF THE TOE NAILS IN THE RAFTER AND CEILING JOIST SHALL EQUAL
OR EXCEED THE TABULATED NUMBER OF NAILS REQUIRED
12
193
t91
280
264
235
280
341
284
280
427
339
280
----
23 7
16
2
-11 .9
15 1
325
-274
-15,6
421
-12 1
-411
526
17
BLOCKING TO SILL OR TOP PLATE (TOE -NAILED)
3-16D
20
282
LEDGER STRIP TO BEAM (FACE -NAILED)
3-16D
386
19
JOIST ON LEDGER TO BEAM (TOE -NAILED)
500
PER JOIST
20
626
3-16D
PER JOIST --
i6
24
327
PER FOOT
22
a47N%
BD
580
DIAGONAL BOARD SHEATHING
726
1" X 6" OR i" X W
2-8D
28
371
t" X 10" OR WIDER
3-81)
509
24
GYPSUM WALLBOARD
660
7"EDGE/ 10"FIELD
25
826
BD
(SEE TABLE 3 8)_
26
32
416
\\
570
6D
3" EDGE/ 6" FIELD
740
25/32"
BD
927
75
NIL
73 f
DGS
NW
T(r
27
GYPSUM WALLBOARD
5D COOLERS
7" EDGE/ 10" FIELD
28
HARDBOARD
BD
(SEE TABLE 3 9)
29
PARTICLEBOARD PANELS
BD
(SEE TABLE 3 9)
30
36
461
4"= T ,0„
DWG, NAME:
632
2-8D
PER SUPPORT
620
T' X 10" OR WIDF_R
3 -BD
1027
31
STRUCTURAL PANELS
LM = CONNECTOR UPLIFT LOAD
L' = CONNECTOR LATERAL LOAD. (PERPENDICULAR TO THE WALL)
T' OR LESS
n -= CONNECTOR SHEAR LOAD (PERALLEL TO THE WALL)
6' EDGE/ 12" FIELD
'TABULATED UPLIFT REQUIREMENTS ASSUME A ROOF/CEILING DEAD LOAD OF PSF(2/3 Y 15 PSF)
SHALL BE PERMITTED TO BE MULTIPLIED BY o 70 AND 0.85, RESPECTIVELY,
FOR FRAMING NOT
' TABULATED UPLIFT AND LATERAL CONNECTION REQUIREMENTS
6 EDGE/ 6" FIELD
LOCATED WITHIN 6 FEET OF BUILDING CORNERS
LOADS ARE SPECIFIED FOR ROOF -TO -WALL CONNECTIONS WHEN CALCULATING UPLIFT LOADS FOR WALL-TO-WALL OR WALL -TO -FOUNDATION
ABOVE,
TABULATED UPLIFT
SHALL BE PERMITTED TO BE REDUCED BY 66 PLF (2/3 X 100 PLF) FOR EACH FULL WALL
CONNECTIONS. TABULATED UPLIFT VALUES
' LENGTH REQUIREMENTS ASSUME A MEAN ROOF HEIGHT OF 33 FEET. FOR MEAN ROOF HEIGHTS OF 15 FEET OR LESS, THE TABULATED VALUES SHALL BE
TABULATED
PERMITTED TO BE MULTIPLIED BY 0.80.
t" X 6" OR V X 8"
SILL OR BOTTOM PLATE TO FOUNDATION ANCHOR BOLT CONNECTIONS
RESISTING LATERAL_ & SHEAR LOADS
PRESCRIPTIVE DESIGN TABLE 3 2A ALTERNATIVE TO TABLE 3 2. (AMERICAN FOREST & PAPER ASSOCIATION)
FOUNDATION BRACING WALL PERIMETER
ANCHOR BOLT
CONNECTION SUPPORTING EDGE NAIL SPACING
2 STORIES ALL
(CRAWL SPACE OR BASEMENT)
k7
1/2" ANCHOR BOLTS
FASTEST -MILE WIND SPEED
(MPH)
90 100 110 120
MAXIMUM ANCHOR BOLT
SPACING (IN)
5/8" ANCHOR BOLTS
FASTEST -MILE WIND SPEED
(MPH)
90 100 Ito 120
MAXIMUM ANCHOR BOLT
SPACING (IN)
36
28
WALL PLATE TO FOUNDATION'1-3 STORIES
(SLAB -ON -GRADE) 6' _ 36 _ 57
L -= CONNECTOR LATERAL LOAD (PERPENDICULAR TO THE WALL)
S CONNECTOR SHEAR LOAD (PERALLEL TO THE WALL)
• ANCHORAGE REQUIRED TO RESIST LATERAL LOADS SHALL BE DETERMINED IN THE FOUNDATION DESIGN PER SECTION 1.1 4
ANCHOR BOLT SPACINGS BASED ON MAXIMUM SHEAR CAPACITY OF UNBLOCKED ROOF' AND/OR FLOOR DIAPHRAMS (279 PLF)
' ANCHOR BOLT SPACINGS BASEDON MAXIMUM SHEAR CAPACITY OF BRACING WALL PERIMETER EDGE NAIL SPACING OF 3" O.0 (731 PLF) BUILT
IN ACCORDANCE WITH SECTION 3 4.4.
' ANCHOR BOLT SPACINGS BASEDON MAXIMUM SHEAR CAPACITY OF BRACING WALL PERIMETER EDGE NAIL SPACING OF 6" O C (421 PLF) BUILT
IN ACCORDANCE WITH SECTION 3 4.4
DESIGN CRITERIA
AMERICAN FOREST AND PAPER ASSOCIATION (AF&PA)
WOOD FRAME CONSTRUCTION
ZONE
REF. TABLE 1609.6.2.1 (1)
X t 53
HOOF > 30° - 40°
MAIN WINDFARCE-RESISTING SYSTEM WIND LOADS FOR A BUILDING WITH
ROOF HEIGHT OF 30 FEET LOCATED IN EXPOSURE Ba
WIND SPEED
3
HORIZONTAL LOADS VERTICAL LOADS____
38.3
-30.3
WIND LOAD ROOF
120 M/HR
CEILING JOIST TO PARALLEL RAFTER (FACE -NAILED)
VELOCII-i DIRECTION ANGLEEND ZONE INTERIOR ZONE END ZONE INTERIOR ZONE
_ _
WINDWARD
OVERHANG
4
90
100
WALL
ROOF
WALL
ROOF
WINDWARD
LEEWARD
N/INDWAR
LEEWARD
END
INTERIOR
- ---
8
3
3
3
3
2-16D
10
ROOF
ROOF
ROOF
ROOF
ZONEZONE
10D BOX NAILS SHALL BE PERMITTED TO BE SUBSTITUTED FOR BD COMMON NAILS
' WHEN CEILING JOISTS ARE INSTALLED PARALLEL TO RAFTERS, THE SUM OF THE TOE NAILS IN THE RAFTER AND CEILING JOIST SHALL EQUAL
OR EXCEED THE TABULATED NUMBER OF NAILS REQUIRED
TRANSVERSE
30°,ANGLE < 45°
25 7
17 6
20.4
140
9 9
15.6
8 6
-13.4
-71,6
-13.0
120
----
23 7
--
ALL ANGLES
22 8
-11 .9
15 1
-7 0
-274
-15,6
-19 1
-12 1
-411
-32.7
DESIGN CRITERIA
REF. TABLE R301.2(2),
AMERICAN FOREST AND PAPER ASSOCIATION (AF&PA)
WOOD FRAME CONSTRUCTION
ZONE
ROOF > 30° - 40°
X t 53
HOOF > 30° - 40°
X 1.53
WIND SPEED
3
23 7
38.3
-30.3
-46.4
120 M/HR
RAFTER/CEILING JOIST TO TOP PLATE LATERAL AND SHEAR
CONNECTION REQUIREMENTS
PRESCRIPTIVE DESIGN TABLE 3 3A ALTERNATIVE TO TABLE 3.3 (AMERICAN FOREST & PAPER ASSOCIATION)
FASTENING
COMMON
SPACING
1/2" ANCHOR BOLTS
FASTEST -MILE WIND SPEED
3 8d ,
PER RAFTER
2
CEILING JOIST TO TOP PLATE (TOE -NAILED)
(MPH)
PER JOIST
3
CEILING JOIST TO PARALLEL RAFTER (FACE -NAILED)
(SEE TABLE 37)
EACH IAP
4
90
100
110120
5
RAFTER/
CEILING JOIST
- --
WALL.; HEIGHT
MAXIMUM ANCHOR BOLT
SPACING (IN)
SPACING (IN)
BLOCKING TO RAFTER (TOE -NAILED)
2-8D
EACH END
-
16
- ---
8
3
3
3
3
2-16D
10
9
3
4-16D
3
4
10D BOX NAILS SHALL BE PERMITTED TO BE SUBSTITUTED FOR BD COMMON NAILS
' WHEN CEILING JOISTS ARE INSTALLED PARALLEL TO RAFTERS, THE SUM OF THE TOE NAILS IN THE RAFTER AND CEILING JOIST SHALL EQUAL
OR EXCEED THE TABULATED NUMBER OF NAILS REQUIRED
' TO AVOID SPLITTING, NO MORE THAN 2 TOENAILS SHALL BE INSTALLED IN EACH SIDE OF A RAFTER OR CEILING JOIST WHEN FASTENED
TO A 2 X 6 TOP PLATE
NAILING SCHEDULE
PRESCRIPTIVE DESIGN TABLE 3 1 (AMERICAN FOREST & PAPER ASSOCIATION
NO
CONNECTION
FASTENING
COMMON
SPACING
1
RAFTER TO TOP PLATE (FOE-NAILED)Q 16" O C
3 8d ,
PER RAFTER
2
CEILING JOIST TO TOP PLATE (TOE -NAILED)
3 Bd
PER JOIST
3
CEILING JOIST TO PARALLEL RAFTER (FACE -NAILED)
(SEE TABLE 37)
EACH IAP
4
CEILING JOIST LAPS OVER PARTITIONS
(FACE -NAILED)
(SEE TABLE 3 7)
EACH LAP
5
_
COLLAR TIE TO RAFTER (FACE -NAILED)
(SEE TABLE 3 4)
PER LIE
6
BLOCKING TO RAFTER (TOE -NAILED)
2-8D
EACH END
7
RIM BOARD TO RAFTER (END -NAILED)
2-t 6D
EACH END
e
TOP PLATE TO TOP PLATE (FACE -NAILED)
2-16D
PER FOOT
9
TOP PLATE AT INTERSECTIONS (FACE -NAILED)
4-16D
JOINTS -EACH SIDE
10
STUD TO STUD (FACE -NAILED)
2-160
24" O C,
11
HEADER TO HEADER (FACE -NAILED)
16D
16" O C ALONG EDGES
12
TOP OR BOTTOM PLATE TO STUD (END -NAILED)
2-16D
PER 2 X 4 STUD
13
BOTTOM PLATE TO FLOOR JOIST, SANDJOIST, ENDJOIST
OR BLOCKING (FACE -NAILED)
2-16D
PER FOOT _
14
JOIST TO SILL, TOP PLATE OR GIRDER (TOE -NAILED)
4-16D
PER JOIST
15
BRIDGING TO JOIST (TOE -NAILED)
2-80
EACH END _-
16
BRIDGING TO JOIST (TOE -NAILED)
2-81)
EACH END
17
BLOCKING TO SILL OR TOP PLATE (TOE -NAILED)
3-16D
EACH BLOCK
1B
LEDGER STRIP TO BEAM (FACE -NAILED)
3-16D
EACH JOIST
19
JOIST ON LEDGER TO BEAM (TOE -NAILED)
3 -SD
PER JOIST
20
BAND JOISTS TO JOIST (END -NAIL EO)
3-16D
PER JOIST --
21
BAND JOIST TO SILL OR TOP PLATE (TOE -NAILED)
2-160
PER FOOT
22
STRUCTURAL PANELS
BD
(SEE TABLE 3 B)
23
DIAGONAL BOARD SHEATHING
_
1" X 6" OR i" X W
2-8D
PER SUPPORT
N
t" X 10" OR WIDER
3-81)
PER SUPPORT _
24
GYPSUM WALLBOARD
50 COOLERS
7"EDGE/ 10"FIELD
25
STRUCTURAL PANELS
BD
(SEE TABLE 3 8)_
26
FIBERBOARD PANELS
UU
7/16"
6D
3" EDGE/ 6" FIELD
25/32"
BD
3" EDGE/ 6" FIELD
75
NIL
73 f
DGS
NW
T(r
27
GYPSUM WALLBOARD
5D COOLERS
7" EDGE/ 10" FIELD
28
HARDBOARD
BD
(SEE TABLE 3 9)
29
PARTICLEBOARD PANELS
BD
(SEE TABLE 3 9)
30
DIAGONAL BOARD SHEATHING
4"= T ,0„
DWG, NAME:
1" X 6" OR 1" X B"
2-8D
PER SUPPORT
T' X 10" OR WIDF_R
3 -BD
PER SUPPORT
31
STRUCTURAL PANELS
T' OR LESS
8D
6' EDGE/ 12" FIELD
GREATER THAN V
10D
6 EDGE/ 6" FIELD
32
DIAGONAL BOARD SHEATHING
t" X 6" OR V X 8"
2_SD
PER SUPPORT
1" X 10" OR WIDER
3-8D
PER SUPPORT
' NAILING REQUIREMENTS ARE BASED ON WALL SHEATHING NAILED 6" ON -CENTER AT THE PANELEDGE
IF WALL SHEATHING IS NAILED 3" ON -CENTER AT EHT PANEL EDGE
TO OBTAIN HIGHER SHEAR CAPACITIES, NAILING REQUIREMENTS FOR STRUCTURE MEMERS SHALL BE
DOUBLED, OR ALTERNATE CONNECTORS, SUCH AS SHEAR PLATES,
SHALL BE USED TO MAINTAIN THE LOAD PATH
2 WHEN WALL SHEATHING IS CONTINUOUS OVER CONNECTED MEMBERS, THE TABULATED NUMBER OF j
NAILS SHALL BE PERMITTED TO BE REDUCED TO 1-16D NAIL PER llll
FOOT
GENERAL FLOOR PLAN NOTES
1 DIMENSIONS SHALL TAKE PRECEDENT OVER SCALE DRAWINGS (DO NOT SCALE DRAWINGS),
2 ALL INTERIOR WALLS TO BE COVERED WITH 1/2" GYPSUM BOARD WITH METAL CORNER REINFORCING
TAPE, FLOAT, AND SAND (3 COSTS)
3 WALLS COMMON TO GARAGE AND HOUSE TO HAVE A LAYER UI- 5/8", FIRE RATED GYPSUM BOARD
AT GARAGE SIDE WITH S -O" RETURN ON ADJACENT WALLS AND CEILING. MANUFACTURED LUMBER
REQUIRES 2 LAYERS OF 5/B", FIRE RATED GYPSUM BOARD
4 ALL BATH AND TOILET AREA WALLS ANT CEILING ADJACENT TO WET AREAS TO HAVE WATER
RESISTANT GYPSUM BOARD, OF WALL TILE SET ON WONDERBOARD OR EQUAL,
GENERAL FRAMING NOTES
1 ALL WALLS, 2"X4" AND 2"X6", TO BE STUD GRADE OF BETTER 16" O/C ALL OTHER FRAMING MATERIAL
1"0 BE #2 DOUGLAS FIR OR BETTER.
2 ALL WOOD FRAMING IN CONTRACT WITH CONCRETE OR MASONRY TO BE PRESSURE TREATED
3 PROVIDE DOUBLE FLOOR JOISTS UNDER ALL WALLS PARALLEL TO FLOOR JOIST SPAN DIRECTION
UNLESS OTHERWISE SPECIFIED
4 PROVIDE X -BRACING OR SOLID BLOCKING AT A MAXIMUM OF 8'-O" O/C FOR ALL DIMENSIONAL
LUMBER FLOOR JOISTS
5 FLOOR CONSTRUCTION3/4" TONGUE AND GROOVE PLYWOOD SUBFLOOR. FINISHED MATERIAL TO BE
APPLIED OVER SUSFLOOR. GLUE AND SCREW PLYWOOD DECKING TO FLOOR JOISTS,
6 ALL WINDOW AND DOOR HEADERS TO BE MINIMUM (2) 2"X10" UNLESS OTHERWISE SPECIFIED.
ALL INTERIOR HEADERS TO BE (2) 2"X 10" UNLESS OTHERWISE SPECIFIED
7 PROVIDE FULL SOLID BLOCKING UNDER ALL BEARING WALLS
e ALL BEAMS TO HAVE ADEQUATE BEARING AT EACH END OR AS SPECIFIED
9 AUL FLUSH BEAM AND JOIST INTERSECTIONS TO HAVE GALVANIZED HANGERS.
F TO BE SH 1 �. EXTERIOR GRADE PLYWOOD OR
7/1 TL EXTERIOR WALLS AND ROA SHEATHED WITH
7/16" ((C)SBOSB PLYWOOD PLYWOOD TO SPAN OVERALL PLATES AND HEADERS
11 PROVIDE INSULATION BAFFLES AT EAVE VENTS BETWEEN RAFTER
GENERAL ELEVATION NOTES
1 EXTERIOR FLASHING TO BE CORRECTLY INSTALLED AT ALL CONNECTIONS BETWEEN ROOFS, WALLS,
CHIMINEYS, PROJECTIONS, AND PENETRATIONS AS REQUIRED BY APPROVED CONSTRUCTION
PRACTICES.
2 GENERAL CONTRACTOR TO PROVIDE ADEQUATE ATTIC VENTILATION AND ROOF VENTS
3 PROVIDE APPROPRIATE SOFFIT VENTILATION AT OVERHANGS
EMERGENCY ESCAPE AND RESCUE OPENINGS SECTION R310
1 MINIMUM OF ONE EMERGENCY ESCAPE AND RESCUE OPENING REQUIRED IN EVERY SLEEPING ROOM
2, OPENING SILL HEIGHT TO BE A MINIMUM OF 44 INCHES ABOVE FLOOR
3 NET CLEAR OPENING SIZE TO BE A MINUMUM OF 5.7 SQUARE FEET
4 MINIMUM OF 5 O SQAURE FEET REQUIRED FOR GRADE FLOOR OPENINGS
5 MINIMUM NET CLEAR OPENING SILL HEIGHT LOCATED BELOW ADJACENT GROUND ELEVATIONS,
WINDOW WELL REQUIRED ALLOW FOR DOOR OR WINDOW TO BE FULLY OPENED.
6. MINIMUM OF 9 SQUARE FEET IN HORIZONTAL DIMENSION, MINIMUM WIDTH OF 36 INCHES
(ENCROACHMENT OF 6 INCHES PERMITTED FOR LADDER OR STEPS).
7 PERMANENT COMPLYING LADDER OR STEPS WHERE VERTICAL DEPTH EXCEEDS 44 INCHES.
8 BULKHEAD ENCLOSURES WITH DIRECT EXTERIOR ACCESS PERMITTED IF IN COMPLIANCEWITH MINIMUM
NET CLEAR OPENING REOUIREMBNTS
9 BARS, GRILLES, COVERS AND SCREENS PROHIBITED UNLESS DEVICES RELEASABLE OR REMOVABLE
FROM INSIDE WITHOUT USE OF KEY, TOOL OR EXCESSIVE FORCE.
PERSPECTIVE BUILDING ENVELOPE REQUIREMENTS
UPLIFT STRAP CONNECTION REQUIREMENTS
W
(ROOF -TO -WALL, WALL-TO-WALL, AND
HEATING
WALL -TO -FOUNDATION)
EXTERIOR WALL
PRESCRIPTIVE DESIGN TABLE 3,313 ALTERNATIVE TO TABLE 3.3
BASEMENT WALL
(AMERICAN FOREST & PAPER ASSOCIATION)
g0
100
110
120
R -VALUE
FRAMING SPACING
ROOF SPAN
NUMBER OF BD COMMON NAILS
205750NE 1 B_---
(IN)
(FT.)
END OF 1-1/4" X 20
R-10
R-9,2 FT
R-19
GAGE STRAP"
rn
� N
12 2 3 3 3
O
� H
16 2 3 3 4
a b
20 3 4 3 4
16 24 3 4 4 5
W
28 3 4 4 5
32 4 5 5 6
Y
36 4 4 1 5 7
U4 == CONNECTOR UPLIFT LOAD
L 4 CONNECTOR LATERAL LOAD. (PERPENDICULAR TO THE WALL)
S = CONNECTOR SHEAR LOAD (PERALLEL TO THE WALL)
W
TABULATED UPLIFT REQUIREMENTS ASSUME A ROOF/CEILING DEAD LOAD OF 10 PST (2/3 X 15
PSF), IF A CEILING ASSEMBLY IS NOT PRESENT OR IF THE CEILING ASSEMBLY IS NOT
CONNECTED TO THE ROOF ASSEMBLY, THE TABULATED NUMBER OF NAILS SHALL BE
C)
(CREASED BY 1 NAIL AT EACH END
FOR WALL-TO-WALL AND WALL -TO -FOUNDATION CONNECTIONS, THE TABULATED NUMBER
OF NAILS SHALL BE PERMITTED To BE REDUCED BY 1 NAIL AT EACH OF THE STRAP FOR EACH
W
FULL. WALL ABOVE
GENERAL FLOOR PLAN NOTES
1 DIMENSIONS SHALL TAKE PRECEDENT OVER SCALE DRAWINGS (DO NOT SCALE DRAWINGS),
2 ALL INTERIOR WALLS TO BE COVERED WITH 1/2" GYPSUM BOARD WITH METAL CORNER REINFORCING
TAPE, FLOAT, AND SAND (3 COSTS)
3 WALLS COMMON TO GARAGE AND HOUSE TO HAVE A LAYER UI- 5/8", FIRE RATED GYPSUM BOARD
AT GARAGE SIDE WITH S -O" RETURN ON ADJACENT WALLS AND CEILING. MANUFACTURED LUMBER
REQUIRES 2 LAYERS OF 5/B", FIRE RATED GYPSUM BOARD
4 ALL BATH AND TOILET AREA WALLS ANT CEILING ADJACENT TO WET AREAS TO HAVE WATER
RESISTANT GYPSUM BOARD, OF WALL TILE SET ON WONDERBOARD OR EQUAL,
GENERAL FRAMING NOTES
1 ALL WALLS, 2"X4" AND 2"X6", TO BE STUD GRADE OF BETTER 16" O/C ALL OTHER FRAMING MATERIAL
1"0 BE #2 DOUGLAS FIR OR BETTER.
2 ALL WOOD FRAMING IN CONTRACT WITH CONCRETE OR MASONRY TO BE PRESSURE TREATED
3 PROVIDE DOUBLE FLOOR JOISTS UNDER ALL WALLS PARALLEL TO FLOOR JOIST SPAN DIRECTION
UNLESS OTHERWISE SPECIFIED
4 PROVIDE X -BRACING OR SOLID BLOCKING AT A MAXIMUM OF 8'-O" O/C FOR ALL DIMENSIONAL
LUMBER FLOOR JOISTS
5 FLOOR CONSTRUCTION3/4" TONGUE AND GROOVE PLYWOOD SUBFLOOR. FINISHED MATERIAL TO BE
APPLIED OVER SUSFLOOR. GLUE AND SCREW PLYWOOD DECKING TO FLOOR JOISTS,
6 ALL WINDOW AND DOOR HEADERS TO BE MINIMUM (2) 2"X10" UNLESS OTHERWISE SPECIFIED.
ALL INTERIOR HEADERS TO BE (2) 2"X 10" UNLESS OTHERWISE SPECIFIED
7 PROVIDE FULL SOLID BLOCKING UNDER ALL BEARING WALLS
e ALL BEAMS TO HAVE ADEQUATE BEARING AT EACH END OR AS SPECIFIED
9 AUL FLUSH BEAM AND JOIST INTERSECTIONS TO HAVE GALVANIZED HANGERS.
F TO BE SH 1 �. EXTERIOR GRADE PLYWOOD OR
7/1 TL EXTERIOR WALLS AND ROA SHEATHED WITH
7/16" ((C)SBOSB PLYWOOD PLYWOOD TO SPAN OVERALL PLATES AND HEADERS
11 PROVIDE INSULATION BAFFLES AT EAVE VENTS BETWEEN RAFTER
GENERAL ELEVATION NOTES
1 EXTERIOR FLASHING TO BE CORRECTLY INSTALLED AT ALL CONNECTIONS BETWEEN ROOFS, WALLS,
CHIMINEYS, PROJECTIONS, AND PENETRATIONS AS REQUIRED BY APPROVED CONSTRUCTION
PRACTICES.
2 GENERAL CONTRACTOR TO PROVIDE ADEQUATE ATTIC VENTILATION AND ROOF VENTS
3 PROVIDE APPROPRIATE SOFFIT VENTILATION AT OVERHANGS
EMERGENCY ESCAPE AND RESCUE OPENINGS SECTION R310
1 MINIMUM OF ONE EMERGENCY ESCAPE AND RESCUE OPENING REQUIRED IN EVERY SLEEPING ROOM
2, OPENING SILL HEIGHT TO BE A MINIMUM OF 44 INCHES ABOVE FLOOR
3 NET CLEAR OPENING SIZE TO BE A MINUMUM OF 5.7 SQUARE FEET
4 MINIMUM OF 5 O SQAURE FEET REQUIRED FOR GRADE FLOOR OPENINGS
5 MINIMUM NET CLEAR OPENING SILL HEIGHT LOCATED BELOW ADJACENT GROUND ELEVATIONS,
WINDOW WELL REQUIRED ALLOW FOR DOOR OR WINDOW TO BE FULLY OPENED.
6. MINIMUM OF 9 SQUARE FEET IN HORIZONTAL DIMENSION, MINIMUM WIDTH OF 36 INCHES
(ENCROACHMENT OF 6 INCHES PERMITTED FOR LADDER OR STEPS).
7 PERMANENT COMPLYING LADDER OR STEPS WHERE VERTICAL DEPTH EXCEEDS 44 INCHES.
8 BULKHEAD ENCLOSURES WITH DIRECT EXTERIOR ACCESS PERMITTED IF IN COMPLIANCEWITH MINIMUM
NET CLEAR OPENING REOUIREMBNTS
9 BARS, GRILLES, COVERS AND SCREENS PROHIBITED UNLESS DEVICES RELEASABLE OR REMOVABLE
FROM INSIDE WITHOUT USE OF KEY, TOOL OR EXCESSIVE FORCE.
PERSPECTIVE BUILDING ENVELOPE REQUIREMENTS
WINDOW AREA 30% OF GROSS EXTERIOR WALL AREA
W
MAXIMUM MAXIMUM
HEATING
GLAZING CEILING
EXTERIOR WALL
FLOOR
BASEMENT WALL
SLAB PERIMETER
I CRAWL SPACE
DEGREEE DAYS
U -FACTOR R -VALUE
R -VALUE—
R -VALUE
R -VALUE
R -VALUE & DEPTH,
WALL R -VALUE
205750NE 1 B_---
045 R-313
R-18
R-19
R-10
R-9,2 FT
R-19
rn
� N
O
� H
a b
CLIMATE AND GEORGRAPHIC DESIGN CRITERIA
TABLE 301.2 (RESIDENTIAL CODE OF NEW YORK)
NOTE:—
GENERAL CONTRACTOR SHALL VERIFY GROUND WIND SEISMIC SUBJECT TO DAMAGE FROM WINTER
THAT THE HEIGHT OF THE STRUCTURE show DESIGN DESIGN
LOAD PEED (MPH) CATEGORY WEATHERING FROST LINE TERMITE DECAY TEMP.
DOES NOT EXCEED THE MAXIMUM DEPTH
HEIGHT OF TOWN REQUIREMENTS LOAD BEARING
AFTER FRAMING THE SECOND FL. AND
VALUE OF
EXPOSURE CATEGORY B SOIL 3,000 PSF MODERATE TO SLIGHTLY TO
RIDGE IF MEASURES HIGHER, ADJUST 45PSF 120 MPH B SEVERE' 12"FOOTINGS HEAVY MODERATE ZONE 11B 11
ROOF PITCH AFTER NOTIFYING THE USE -16"
ARCHITECT OF THIS FIELD CONDITION. _--------- -----' ---- -- -----
ICE SHIELD
UNOERL.AYMENT
REQUIRED
YES
THESE DRAWINGS AS INSTRUMENTS OF SERVICE.
ARE THE SOLE PROPERTY OF THE ARCHITECT
NO REVISIONS, CHANGES, ANO/OR MODIFICATIONS
SHALL BE ALLOWED WITHOUT WRITTEN AUTTIORIZ.ATION
BYTHEARCHITECT ANY REPRODUCTION IN PART
OR WHOLE IS SIRICTLYPRCI IISITED BY LAVA
c
W
5
a
�1/
V
O
� �
O P
U
r �
u^
u
n
�w
rn
� N
O
� H
a b
W
Ucc
Y
Z
W
W
C)
Z
U)
W
cc
J
0
N
No
�
0
,/
CL
U°
❑
W
N
0
�
Q
o
a
W
�
�
D
D
UU
m�
O
❑3
0
❑2
0�
OQ
75
NIL
73 f
DGS
NW
T(r
JQ
NU
NW
D
W
O
O
O
O
O
SCALE:
4"= T ,0„
DWG, NAME:
NOTES
OwG No.:
A.3
PANEL LEGEND
(REF�_=R TO TABLE 1609.1.4)
ALTERNATIVE FOR OPENING PROTECTION
WOOD STRUCTURAL PANELSWITH A MINIMUM THICKNESS OF 7/16" AND MAXIMUM PANEL SPAN OF 8'-0"
PANEL SIZE
SHALL BE PRECUT TO COVER GLAZED OPENINGS WITH ATTACHMENT HARDWARE PROVIDED
REF
TYPE AND # OF SCREWS
Ory'
WIDTH HEIGHT
PANEL SPAN <
2'-0"
*B SCREWS (V 12" O C
4'-D" < PANEL
SPAN - 6'-0"
6'-0" , PANEL
SPAN < 8'-0"
'A
HORIZONTAL- 6 VERTICAL - 6
8'-3" X 5--111,
1
9
#8 SCREWS @ 16" O C,
•Ib
16
B
HORIZONTAL -9 VERTICAL -5
W
I
NOTE:
REFER TO A.1 & A 2 WINDOW & DOOR SCHEDULES FOR PANEL LOCATIONS
1 1/2" #8 WOOD SCREWS
12 12 16
6'-0" < PANEL 6-0" < PANEL 2'-0" < PANEL
SPAN SPAN < 8'-0" SPAN a 6-0"
ALTERNATIVE FOR OPENING PROTECTION
WOOD STRUCTURAL PANELSWITH A MINIMUM THICKNESS OF 7/16" AND MAXIMUM PANEL SPAN OF 8'-0"
SHALL BE PERMITTED FOR OPENING PROTECTION IN ON AND TWO STORY BUILDINGS, PANELS
SHALL BE PRECUT TO COVER GLAZED OPENINGS WITH ATTACHMENT HARDWARE PROVIDED
(REFER TO SECTION 1609 1 4 ABC 1609 6.5 AND TABLE 1609.1 4)
TABLE 1609.1 .4
WINDBORNE DEBRIS PROTECTION FASTENING SCHEDULE FOR WOOD STRUCTRAL PANELS
FASTENER TYPE
PANEL SPAN <
2'-0"
2-0" - PANEL
SPAN c 4'-O"
4'-D" < PANEL
SPAN - 6'-0"
6'-0" , PANEL
SPAN < 8'-0"
,
16
16
12
9
1 1/2" #8 WOOD SCREWS
•Ib
16
16
12 —
W
I
..A"
Q
z
Lu
1..V
J
0.
NOTE:
REFER TO A.1 & A 2 WINDOW & DOOR SCHEDULES FOR PANEL LOCATIONS
1 1/2" #8 WOOD SCREWS
12 12 16
6'-0" < PANEL 6-0" < PANEL 2'-0" < PANEL
SPAN SPAN < 8'-0" SPAN a 6-0"
ALTERNATIVE FOR OPENING PROTECTION
WOOD STRUCTURAL PANELSWITH A MINIMUM THICKNESS OF 7/16" AND MAXIMUM PANEL SPAN OF 8'-0"
SHALL BE PERMITTED FOR OPENING PROTECTION IN ON AND TWO STORY BUILDINGS, PANELS
SHALL BE PRECUT TO COVER GLAZED OPENINGS WITH ATTACHMENT HARDWARE PROVIDED
(REFER TO SECTION 1609 1 4 ABC 1609 6.5 AND TABLE 1609.1 4)
TABLE 1609.1 .4
WINDBORNE DEBRIS PROTECTION FASTENING SCHEDULE FOR WOOD STRUCTRAL PANELS
FASTENER TYPE
PANEL SPAN <
2'-0"
2-0" - PANEL
SPAN c 4'-O"
4'-D" < PANEL
SPAN - 6'-0"
6'-0" , PANEL
SPAN < 8'-0"
1 1/2" #6 WOOD SCREWS
16
16
12
9
1 1/2" #8 WOOD SCREWS
16
16
16
12 —
W
I
Q
z
Lu
1..V
J
0.
N
No
i
CU
o
0•.
Q
o
U�
7
I
N
N
v'.
0
0
0
w
H
W
CO
o
v
m3
NOTE:
REFER TO A.1 & A 2 WINDOW & DOOR SCHEDULES FOR PANEL LOCATIONS
1 1/2" #8 WOOD SCREWS
12 12 16
6'-0" < PANEL 6-0" < PANEL 2'-0" < PANEL
SPAN SPAN < 8'-0" SPAN a 6-0"
ALTERNATIVE FOR OPENING PROTECTION
WOOD STRUCTURAL PANELSWITH A MINIMUM THICKNESS OF 7/16" AND MAXIMUM PANEL SPAN OF 8'-0"
SHALL BE PERMITTED FOR OPENING PROTECTION IN ON AND TWO STORY BUILDINGS, PANELS
SHALL BE PRECUT TO COVER GLAZED OPENINGS WITH ATTACHMENT HARDWARE PROVIDED
(REFER TO SECTION 1609 1 4 ABC 1609 6.5 AND TABLE 1609.1 4)
TABLE 1609.1 .4
WINDBORNE DEBRIS PROTECTION FASTENING SCHEDULE FOR WOOD STRUCTRAL PANELS
FASTENER TYPE
PANEL SPAN <
2'-0"
2-0" - PANEL
SPAN c 4'-O"
4'-D" < PANEL
SPAN - 6'-0"
6'-0" , PANEL
SPAN < 8'-0"
1 1/2" #6 WOOD SCREWS
16
16
12
9
1 1/2" #8 WOOD SCREWS
16
16
16
12 —
NOTE: ALL STRAPPING TO GO BENEATH
EXTERIOR SHEATHING. (TYPICAL ALL)
1Od NAILS OR —
16d SINKERS
3" O.0 VERTICAL
4" O C HORIZONTAL
STRONG -WALL
SHEARWALL —
(TYPICALAT
EACH CORNER)
PRE -ATTACHED
PHD6 WITH
(12 SDS 1/4X3
FASTENERS
1' ,I
SILL PLATE TO
FOUNDATION
USING USP BEARING
PLATE FASTENERS
(HSPS/LBPS)
TRUSS BRACING
(MTS12)
TRUSS/RAFTER
TO TOP PLATE
(RPS4)
STUD
STUD TO BAND JOIST
(CS16)
HEADER ANCHORAGE
(LSTA18)
PROV. 11 7/8" BOX BEAM
SILL PLATE TO
FOUNDATION
PSING USP BEA
LATE FASTEENERS G
(HSPS/LBPS)
SILL PLATE TO
FOUNDATION
(BP)
PROV. METAL FLASHING
AT WINDOW LCATIONS)
METAL FASTENER SCHEDULE 11
Zl='"35 1III
RIDGEWITH (16) 1Od X 1 1/2 FASTENER
BEAM 1z(STRAP REQUIRED FOR 16" JOIST
DEPTH OR MEMBERS WITH SLOPE'
OF 7/12 OR GREATER),
2" X 10" R.R
CONNECTION OF RIGDE D1
BEAM TO ROOF RAFTER Al —1
(EXAMPLE)
1 SCREW THROUGH
BRACE AT EACH
FLANGE
75"X 33 MIL
X- BRACING D3
(EXAMPLE) A1-1
V
V
F
PROV, LIFETIME "GAF" ASPHALT
BELOW GRADE
(tXPJVIF'Lt)
CORNER CONNECTION D2
(EXAMPLE) Al -1
CLIP ANGLE (BOTH SIDES OF
CONNECTION) MIN. LENGTH = JOIST
WEB DEPTH MINUS 1/2"
a SCREWS (4 PER LEG
JOIST TO HEADER JOIST D4
(EXAMPLE) Al -1
SOUTH ELEVATION-SK2
MET/
CON
2" X 8" BLOCKING
(2) 2" X 4" TOP PLATE
2"X10"RAFTER
RAFTER BRACING MTS12 STRAP
WITH (7) 1Od X 1 1/2 FASTENER
TO STUD AND RAFTER
1 11
BIRDSMOUTH CUT D7
LOW END OF JOIST ONLY
(EXAMPLE)
SHFATING
CONNECTION OF TOP D6
WALL PLATE TO WALL STUD.
TO
DS
(3
N
F
PILE
.ND JOIST
FLOOR FRAMING
TWO- MEMBER FLOOR
SUPPORT BEAM
)NNECRON OF FLOOR FRAMING
J SUPPORT BEAM, SIMPSON LTS12
STRAP WITH (12) 1 O X 1 1/2" FASTENER
INTO FLOOR JOIST AND SUPPORT BEAM
CONNECTION OF FLOOR FRAMING D9
110SUPPORTAl —1
(EXAMPLE)
WALL STUD
WALL STUD
u BOTTOM PLATE
BAND JOIST
\ TWO- MEMBER FLOOR SUPPORT BEAM
PILE CONNECTION OF WALL TO FLOOR FRAMING
SIMPSON LSTA111 STRAP WITH
(12) 1 O FASTENER
CONNECTION OF
SIMPSON LTT04STRAP (12)) 8d X 11 1S2PPORT
CONNECTION OF WALL
TO FLOOR FRAMING. Al -1
(EXAMPLE)
THESE DRAWINGS AS INSTRUMENTS OF SERVICE,
ARE THE SOLE PROPERTY OF THE ARCHITECT
NO REVISIONS, CHANGES, ANO/OR MODIFICATIONS
SHALL 6RE Al -LOWED Y THEARCHITECT. ANY HREPRODUCTION IN O AUTHORIZATION
OR WHOLE M STRICTLY PRO141DITEO BY LAW.
W 5
Z
z
r
OE
O ] N
z
1 O
u
� w
a�
o &o
m N
Lu
U�
Z°
W
W
Q
z
Lu
1..V
J
0.
N
No
CU
o
0•.
Q
o
U�
7
I
N
N
0
0
0
w
H
W
CO
o
v
m3
0
0
OW
Oz
02
W
N
NQ
N�
W
o
�O
pop1
O
O
N
a
v
n
SCALE:
DWG. NAME:
BUILDING
SECTIONS
DWG. NO.'
A.4