Loading...
HomeMy WebLinkAbout31782-Z FORM NO. 4 TOWN OF SOUTHOLD BUILDING DEPARTMENT Office of the Building Inspector Town Hall Southold, N.Y. CERTIFICATE OF OCCUPANCY Date: 08/10/06 No: Z-31748 THIS CERTIFIES that the building SOLAR PANELS Location of Property: 3430 (HOUSE NO.) County Tax Map No. 473889 Section 55 BOISSEAU AVE (STREET) Block 3 SOUTHOLD (HAMLET) Lot 9 SUbdivision Filed Map NO. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated FEBRUARY 6, 2006 pursuant to which Building Permit NO. 31782-Z dated FEBRUARY 8, 2006 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is INSTALLATION OF SOLAR PANELS IN AN EXISTING ACCESSORY GARAGE AS APPLIED FOR. The certificate is issued to RICHARD & MICHELLE FEELEY (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL N/A 03/06/06 ELECTRICAL CERTIFICATE NO. 106607C PLUMBERS CERTIFICATION DATED N/A ~..~ Authorized Signature Rev. 1/81 Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 f'/' \ \' \lI\j1:> L l~S APPLICATIONFORCERTlFICATEOFOCCUPANCY ~~ ~~"'- ~~ This application must be filled in by typewriter or ink and subillltted to the Building Department with the following: ".~ A. For new building or new use: 1. Final survey of property with accurate location of all buildings. property lines, streets, and unusual natural or topographicfeatures. On hie- 2. Final Approval from Healtb Dept. of water supply and sewerage-disposal (S-9Jorm). n/Il- 3. Approval of electrical installation from Board of Fire Underwriters. e nr{ 05 e / 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of I % lead. 0,11 5. Commercial building, industrial building, multiple residences and similar buildings and installations, a cer1ificate of Code Compliance from architect or engineer responsible for the building. hfA 6. Submit Planning Board Approval of completed site plan requirements.1IJ B. For existing buildings (prior to April 9, 1957) non-conforming uses, or buildings and "pre-existing" land uses: 1. Accurate survey of property showing all property lines, streets, building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied, the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees I. Certificate of Occupancy - New dwelling $25.00, Additions to dwellin .00 Alterations to dwelling $25.00, Swimming pool $25.00, Accessory building $25.00 Additions to accessory building $25.00, usinesses $50.00. 2. Certificate of Occupancy on Pre-existing Building- 3. Copy of Certificate of Occupancy - $.25 4. Updated Certificate of Occupancy - $50.00 5. Temporary Certificate of Occupancy - Residential $15.00, Commercial $l5 .00 7/z 15 )Ch Date. New Construction: v Old or Pre-existing Building: BOI SSea.LI Avenue- (check one) ~ v#,olct Location of Property: 3Lf3D House No. Owner or Owners of Property: ~-cMtu'ZI Street Hamlet Health Dept. Approval: Planning Board Approval: 01A ~IA 4- Wllchelle FeeJa; 55 Block :5 Filed Map. ,..;/4 Lot:~_ Applicant: ~ Strt'(lfY} U.5A Underwriters Approval: enuosed t/)p'l Lot q Suffolk County Tax Map No 1000, Section tV/A Subdivision 311<6~-r Date of Permit z/Cb Pennit No. Request for: Temporary Certificate /)..... .00/. Fee Submitted: $ ~'::) Final Certificate: vi ( check one) lM~~ Applicant Signature r &..~. 7015<{ CO :C3f7!{ Y PO, / q / 7,50 v'f~ rCl FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 31782 Z Date FEBRUARY 8, 2006 permission is hereby granted to: RICHARD & MICHELLE FEELEY PO BOX 1917 SOUTHOLD,NY 11971 for : INSTALLATION OF SOLAR PANELS AS APPLIED FOR at premises located at 3430 BOISSEAU AVE SOUTHOLD County Tax Map No. 473889 Section 055 Block 0003 Lot No. 009 pursuant to application dated FEBRUARY 6, 2006 and approved by the Fee $ 150.00 Building Inspector to expire on AUGUST ORIGINAL Rev. 5/8/02 311t~:2- TOWN OF SOUTHOLD BUILDING DEPT. 765.1802 INSPECTION [ ] FOUNDATION 1 ST [] ROUGH PLBG. [ ] FOUNDATION 2ND [] INSULATIO ~ [ ] FRAMING I STRAPPING ~INAL ~~zt ..... "SJ [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFE ~-ECTI . ~ REMARKS: ~ 7 DATE 1,- J ,.-1) f INSPECTOR ~~ . . , . - FIELD INSPECTION REPORT DATE COMMENTS \)J... _f'l FOUNDATION (1ST) --J~ ~=l >....>"" ------------------------------------ ..., u. :"1)0 FOUNDATION (2ND) ~-'" ~~ f'l Il>- Z P W'" "''''' ROUGH FRAMING & \)Jr;;] PLUMBING cJ ;:J \}0 .Q . ~ ~~ ~t"' INSULATION PER N. Y. m;:J STATE ENERGY CODE 1rJr()). ~ .F-. 1/ , ~o-k:. ~ , r ~ #OQ A 0 Ftl'L~~ ~ --/- P,-;> ~ V FINAL 6 ADDITIONAL COMMENTS ~ 0 0 ::E ,N~ 06!::1 \ ... 0(\- . ~ o = -.J~ z;~ --t!:; J>:d e! f'l ... :-' ., II t'18 @, 110 I). c.. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF CODES OF NEW YORK STAT~ ~ _\ l- +\ P'*'L;w [.aA;!h> AU fb Fo1AP~ " -- V'GAt? VOAD - I '7 P.e",:; t'~MOW l.-CAO.... A '7 p;.~ APf.'W:D AS NOTED --\\JlfJV' k:lAO...IZD f.-1P'~ DATE:-'/t:.~,8?#JO.t1"be. ~%I~H~ ~W ~EJI I /n.",. ';j),P1l!- NOTIF ':"'.\:" , '{ .;;:mX:~H AT ~.' ,i ,'Of~ THE . "'".IT '"\~.::~. "] ~ T\Y -',-, <JiRED o UNDERWRITERSCERTIACATE REQUfiD CERTIFICATION OF NAILING & CONNECTIONS REQUIRED. - 0- Af'fll- . t"ot,.A.Q... ,,~ I:;f).,j L/7 ~'< " ,..-.c" ,-" .;.J lA ::, .'t,~\i, " ,':E:~~G YOR ST DESI N C ,')N MUST . (). . .:i-L':, : ',EET THE )F THE cr 'ES OF NEW ~-T :::J<;[-\.~ ~SIBLE FOR :,3TRUCTI ERRORS, ~ OCCUPANC ~ 1t-I'O'1 " '. fUSE IS UNLAW~__,____~_?Z-''''Oll ,}- WITHOUl CERTIFICATE .,<r.~~.T'>t:.>,.. eJl t~~Oj.j 11+rw ~\v(~ OCCUPANCU'\ 1Z6Afl. ~ flAW (f~..:,,'.'~.' " "~"'.'.'.<.'\. j!o'ft: ~~~"" '1.1 ~,"""~ ""'.",~ V Ifg" ~ I' -0' (~~v 1 1+.w6 e>66U ~AlU6l7 flWH f'~lf 11\I,('::;7, ot-j l,01" f-..IO, loeo - t?~ __07'S.:~~_,>'/ ~~ II-I~?~ ~vD~, P6pr', ",-:~,-~fi)3>' Elizabeth Thompson Arch,tect f~~ INI AI..( C; I Date 1/~/af.t, 250 Mercer St. Suite B 806 New York, NY 10012 212-614-7180 Title Scale ~O~Aj2. PAUe;l" D~fA11h> At-;. ~e'1CP >.<--. Panel Layout for Rich Feeley 4900 watt system All Plnlll IrB Flclng South on dellched Garlge 1.5 31.0 1.0 31.0 1.0 31.0 1.0 31.0 1.0 31.0 1.0 31.0 1.0 31.0 1.0 31.0 1.5 31.0 1.0 31.0 1.5 I E M M M M M M M M M E 1 2 3 4 5 6 7 8 9 10 E M M M M M M M M M E I Bolted Splice Bolted Splice 1 5 31 0 1 0 31 0 1 0 31 0 1 0 31 0 1 0 31 0 1 0 31 0 1 0 31 0 1 0 31 0 1 5 31 0 1 0 31 0 1 0 I E M M M M M M M M M E 11 12 13 14 15 16 17 18 19 20 E M M M M M M M M M E I Bolted Splice Bolted Splice 1.6 31.0 1.0 31.0 1.0 31.0 1.0 31.0 1.0 31.0 1.0 31.0 1.0 31.0 1.0 31.0 1.5 I E M M M M M M M E 21 22 23 24 25 26 26 27 E M M M M M M M E I Bolted Splice ---r- 37.5 I 26.5 -+- 37.6 I 26.6 -+- 37.6 -L- LA'(~()T" E'r <;oI.lSi~A~ lAsA I/Or." " TOWN OF SOUTHOLD BUILDING DEPAR'fMli;NT FEB 1 TOWN HALL SOUTHOLD, NY 1l97~ TEL: (631) 765-1802 FAX: (631) 765-9502 www.northfork.netlSoutholdl PERMIT NO. Examined J>- t- 20 1. ;t-/ i :20~ / , ?1-rrZ-b BUILDING PERMIT APPLICATION CHECKLIST Do you have or need the following, before applying? Board of Health 4 sets of Building Plans Planning Board approval Survey Check Septic Form N.Y.S.D.E.C. Trustees Contact: j. :')'It.,:"'> ' ___-1 Approved Disapproved ale Mail to: Expiration I '1' / ~ ,20Y Phone: APPLICATION FOR BUILDING PERMIT Date ~ A1\.J ~ \ ,20~ INSTRUCTIONS a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 3 sets of plans, accurate plot plan to scale. Fee according to schedule. b. Plot plan showing location oflot and of buildings on premises, relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application, the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e. No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. lfno zoning amendments or other regulations affecting the property have been enacted in the interim, the Building Inspector may authorize, in writing, the extension of the permit for an addition six months. Thereafter, a new permit shall be required. APPLICA nON IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance ofthe Town of South old, Suffolk County, New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances, building code, housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. ~~bifa~rporatiOn) Z'70 t-IlS~ ~T'. ~~Ob tvE\.\j '(oruL , f'V'i 1= 12. (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder A\U..HITEor Name of owner of premises _\2., '-14 f I"::r::; Le"'( (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. Plumbers License No. Electricians License No. lP,q.; (l/.\t>l.E G't..eGT2U) ;;go;?,o. M€ (SUt-l~rI2-€AM U....A) Other Trade's License No. 1. Location of land on which proposed work will be done: ~4~o ~~Au A~ House Number Street <;. 0 <.l T1-tot.. b Hamlet County Tax Map No. 1000 Section '7 t7 Subdivision Block ? Filed Map No. Lot ~ Lot (Name) " 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existinguseandoccupancy SIt-.lI>.IF fA""'L'1 tzE:c;.'bE~U.; b. Intended use and occupancy <;;.\ 'k.)(.\.Ae. FA-MI l...'1 e.E:c;.Il"\E"-lU'::: 3. Nature of work (check which applicable): New Building Repair Removal Demolition Addition Alteration Other Work <;OLof.l.g PAt-3E"l.. 1~~Tp,.lAAT10t...) $I. ~ (Description) 01>) "IAeI4G,6" Fee I'!E>'O. (To be paid on filing this application) Number of dwelling units on each floor 4. Estimated Cost ~ Zc:>, 4i?D. - 5. If dwelling, number of dwelling units If garage, number of cars 6. Ifbusiness, commercial or mixed occupancy, specifY nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front Height Number of Stories Rear Depth Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction: Front Height Number of Stories Rear Depth 9. Size oflot: Front Rear Depth 10. Date of Purchase Name of Former Owner 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation? YES_NO L 13. Will lot be re-graded? YES_NO ~ Will excess fill be removed from premises? YES_NO )( !.+Jo ~lW Au€ Address ~UT1o\o"'b. \..l'1' Phone No. ib; I - 7 "",. 4,-" Address ~M~~~tllOIoPhoneNo "Z,2.. C.'~-1Iro Address 11" ""'"".... """ 'I' Phone No. !OS 1- Zi'~ - 00<;7 ':;OVn1,A>M PTOfV I N'-( 15 a. Is this property within 100 feet ofa tidal wetland or a freshwater wetland? *YES_NO ~ * IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAYBE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES_NO---X- * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 14. Names of Owner of premises f,'C-1+ ~6en.e'f Name of Architect ~l.o\z.AogeTli- '-I-IoMl"Oolo-:> Name of Contractor '51.l~TlUi!;""" lA'i.A 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. STATE OF NE~~ns' COUNTY OF W L D J-ZL 5' ---- being duly sworn, deposes and says that (s )he is the applicant e of individual signing co ct) above named, (S)He is the klJf / r-+u.t-l111':Dj I (Contractor, Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. Sworn to before me this! I day of /~ /) /loA____L/;'''-c(.J.-.---'<-.-- 20 0 c. ;kMc Notary Public Signature of Applicant .- . <- DIANNE MARROCOLLA Notary Public, State of New Vorl< No. 01 MA5037693 Qualified in QUirens County /) /~j 0 /7 8ommiss~on El.pires Jan. 3. <..-+U f h:=.=~, ~~A4--I'_J"- 1//')(_ .>- ~ THE STANDARD IN PV MOUNTING STRUCTURES SOLARMOUNI: PV MODULE MOUNTING SYSTEM SOLARMOUNl: Module Bolt Slot Clip Slots Footing Bolt Slot SolarMount. Rails o The heart of the system. Four mounting slots in the SoIarMount" rail give you ultimate flexibility for module mounting and foot placement. Clamp modules to the rails from the top, freeing yourself from the con- straint of the module mounting holes. Or clip and bolt modules from the bottom to either side of the rail. The footing bolt slot gives you complete freedom of footing placement. You'll always be able to hit the rafter. Top Mounting Clamps f) Mount your modules to the rail from the top. This is ideal for flush mount applications, such as residen- tial rooftops, where it is most conven. ient to pre-assemble rails and footings before installing modules. Clamps also free you from the constraints of module mounting holes. Achieve a secure attacIunent anywhere along a module's frame. Bottom Mounting Clips o Use bottom mounting clips whenever you prefer to attach rails directly to the module mounting holes. Simply fit the clip into its rail slot over the mounting bolt for a secure connection. Adjust the clip position anywhere within the rail slot. A1igmnent of rails to module mounting holes is always easy and convenient. o Strut-in-Thbe Strut-in-Thbe Style Legs o Quickly set the precise tilt angle required. Styles are available for high profile (lor 2 legs per rail) and low profile installations. Each series offers three leg lengths so that you can adjust to exactly the tilt angle you want - up to a maximum of 60 degrees - without cutting and drilling at the job site. i Il . Standoff Steel IJ Flat Thp " I) L-Feet L-feet I) Standard for ground mount installations. Use them in many resi- dential rooftop installations as well, patticularly with asphalt composition shingles, and in many commercial roofing applications. Rail mounting holes are at two heights. In flush mounts, use the upper hole to raise the modules and promote air flow for cooling. Where aesthetics are the greater concern, use the lower hole to keep the modules close to the roof. fi G Standoff ',' Aluminum lWo Piece .- ~ "- ';:'ijh.,. '_1 I ~ 1 o Standoff Steel Raised Flange i 1 ~ . , ;. " ~""~I ..~ i;~ "M;> t',.;< g. , 11>:'" W-O{ ~ ~,':j" """ '-.'.' ,'" .,'.r ),,, j i i €I Splice Bar "v Standoffs and Splices G Use standoffs whenever flashed installations are required- on tile roofs, for example. Our new two-piece aluminum standoff allows precise placement of a flashing over a secured base prior to the installation of the standoff itself. All three types come in a range of standard heights-3, 4, 6, or 7 inches. Choose a flashing that's a perfect mate for your standoff and roof type. €I Splice Bars slide into the footing bolt slots of SolarMountOrail sections, joining rails end-to-end in long, flush or low profile installations. -, SOLARMOUNl: PV MODULE MOUNTING SYSTEM Code Compliance SolarMount" Component Specifications The SolarMount"system is PE certified to meet Uniform and California building codes. Our documentation supports your pernritapplication. SolarMount"rails, top-mounting clamps, bottom-mounting clips, tilt legs, I.-feet, and two-piece standoffs: 610S-TS aluminum extrusion. One-piece standoffs: Service Condition 4 (very severe) zinc-plated, welded steel. Fasteners: 304 stainless steel. ~ THE STANDARD IN PV MOUNTING STRUCTURES UniRac, Inc. www.unirac.com 3201 University Boulevard SE. Suite 110 Albuquerque NM 87106-5635 USA 505.242.6411 505.242.6412 Fax Pub 041004-1ds . November 2004- @ 2004 UniRac, Inc. All rights reserved 10 year IimiIm Prodaet Warnmty, 5 year liml'bed FiDisb. w.rnmty UniRac.Inc., warrants to the original pun:baser ("Putthaser") ofprodun(s) that it manufactures ("Product") at lite original installation site that the Product shall be free from <!erects in material. and wodcmanship for a period 01 ten (IO) yeaTS,ext:ept: for the l\llOdized finish, which finish shall be free from visible peeling, or Cl'lrling or chalking: under normal aanospherk conditions for a period of ~ (5) years, from the earlier of 1} the date the installation oftbe Product isoompleted. or 2) 30 days after the purchase of the Product by the original Pwd1aser ("'Finish Warranty"). The Finish Wamulty does not apply to any forejgn m;idue deposited on the finish. All iMtaI1ations in corrosive atmospheric conditions :m' =luded. The FIJIish Wammty Is VOID if the pmetices specified by AAMA 609 &: 610--02 - ~Cleaning and Maintenance for Architecturally Finished Aluminum~ (www.aaroanet.org)arenotfo&wedbyJ>wd1aser.This WIlmmty does not cover damage to the Product that occurs dwing its shipment. Slor3ge. OJ: instaUation. 'Ibis Wammty shall be VOID if installation of the Product is not pedormed in accordance with UniRac's written installation instructions. or if the Product has been modified, repaired. OJ: rewwked in a manner not previously authorired by UniRBc: IN WRfTING. or if the Product is installed in an environment for which it was IIOt designed. UniRac shall not be liable for consequential, contingent or incidental damages arising out of d:ie use of the Product by Purr:haser under any circumstances. rf wilhin me specified Wammty periods the Product shall be .reasonably proven to be defective, then UniRac shall repair or replace the defective Product, or any part thereof, in UniRac's sole discretion. Such repair or ...placement shall annpletely satisfy and discharge all of UniRac's liability with respect to d:iis limited Wammty. Under no ci=uustances shall thaiRac be liable for special. indirect or ronsequential damages arising out of or.related ro use byl'utd1areroftbe Product. Manu.facturers of related items, such as PV modules and flashings. may provide written warmnties of their own. UniRac's limited Wammly covers only its Product, and nOI any ...1atOO items. ~ , GE Energy IIGEPVp-200-M 200 WATT PHOTOVOLTAIC MODULE FEATURES . 54 poly-crystalline cells connected in series . Peak power of 200 watts at 27.1 volts . Designed for optimum use in residential and commercial grid-tied applications . 25-year limited warranty on power output. 5-year limited warranty on materials ond workmanship' . Pre-wired junction box with MC Connectors BENEFITS . Output power tolerance of +/- 5% . Robust. clear anodized aluminum frame with pre-drilled holes for quick installation . Engineered for the most rugged of locotions including those which experience hail. snow, and ice storms CERTIFICATIONS The GEPVp-200 Module meets the following requirements: @ UL-1703 'RefertoGEEner911ProducIWOffilnt!lfor5pedfH;detoil~ e imaginatian at wark ~ . PHYSICAL CHARACTERISTICS 58.Sin, 1485 mm i I i 38.6 In. : .-- 981mm~-----: 2.2in "'.- 55 mm'- 1.4 in i '-35mm Physical Design Properties Weight 39.0 1b117.7 kgJ __ __,n Weight [Wind) Beonng Potential 5Olbs/ft' {US mph equivalentJ >-.-.----- Hailstone Impact Resistance r 0 50 mph (25 mm @80kph] ELECTRICAL PERFORMANCE Typical IV Curve for GEPVp-ZOO-M Module s- ~ w ~ w ~ :>: '" 3 fa - - - - - - - - - 6 _________n___:~-~:',~ ...... ", \ " \ ", \ '-\ \ . \ \ .~ \ \ . \ 5 4 - 2 - 1000W/m',25"CTceII - - - aooW/m',45"CTcell - - - - 1000 w/m2 . 6O"'C T cell o o 5 15 VOLTS 25 '0 10 2;) r! 29.3 in. I --------743mm-1 - " ~ """-,-. 25.3 in. 643mm ~\<I"nt:ngHole DlGmet~ 0.26 in. 6.7mm~. t- -t 39.6 in. 937mm -'" 16.6io. 421mm Typical Performance Characteristics :leok Pewer lWpl Watts 200 Mox. flOW~f Voltage tvmpt volts 27.1 Mox. Power Current {Imp) Amps 7.4 Open Circuit Voltoge ;Vod Volts 34 Short CirCUIt Current Use! Amps 7.8 Short Circuit Temp. Coefficient mN"C 5.6 Open Circuit Voaoge C.oefficient V/"C -{)12 MCK '?Cfwer Temp. Coefficient %I"C -{)5 01m'__ Senes. Fuse Amps 15 N<Hrna! Operating CeH <leg. C 45 Temperature [NOG] N~(ftwQedIJtStondonlTestQnSilirJns;llmxianlE:ol1OlOWIm'. AM LSG.~tenlpI!J(Jbn2S"Q.Aswlhal~Cf1J5':JIPllHolUls..~the stdJbJlionprOQ!$$thotocanduring lNW_......ww:e.~ powI!fmaydeael:l$ll!~3"IlfnmtypiaJlmllllinun~~" opl:lenomeoof>lcroNnll5LightnllcedDegrodalion\llll.AlI~OIl' guoronteed ottheJomnr.rteIeods. NOCTisI'l'lel'JSl.Q(lQt800'WIrri. 2OderJ.C ambient,lJI1d lrnlswindspnd GE Energy 231 lake Drive NeIMlrk, DE 19702 866-750-3150 gepower.com/solar GfA-14l.t51lMN "'-~ (j- 473889 55.-3-9 NUMBER# DATE TYPE 26593 6/19/00 PERMIT 30679 10/01/04 PERMIT 0100100 0/00/00 0/00/00 0/00/00 0/00/00 0/00/00 0/00/00 0/00/00 OWNER: RICHARD & MICHELLE FEELEY CO # USEIDESCRIPTION 27681 NEW DWELLING INGROUND SWIMMING POOL F1=More F7=Permit Detail F8=Co Detail F9=Preco F12=New Swis/Parcel F3=Exit