HomeMy WebLinkAbout29392-Z
FORM NO. 4
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
Office of the Building Inspector
Town Hall
Southold, N.Y.
CERTIFICATE OF OCCUPANCY
No: Z-31711
Date: 07/27/06
THIS CERTIFIES that the building ANTENNA/EQUIPMENT
Location of Property: 21855 CR 48
(HOUSE NO.)
County Tax Map No. 473889 Section 96
CUTCHOGUE
(STREET) (HAMLET)
Block 1-- Lot 19.1
SUbdivision
Filed Map No.
Lot No.
conforms substantially to the Application for Building Permit heretofore
filed in this office dated
MAY 12, 2003 pursuant to which
Building Permit No. 29392-Z
dated
MAY 19, 2003
was issued, and conforms to all of the requirements of the applicable
provisions of the law. The occupancy for which this certificate is issued
is INSTALLATION OF WIRELESS COMMUNICATIONS ANTENNAS TO AN EXISTING MONOPOLE
& RELATED EQUIPMENT AS APPLIED FOR & AS PER CONDITIONS OF ZBA #5232 DATED
3/30/03.
The certificate is issued to ARTHUR V JUNGE
(OWNER)
of the aforesaid building.
SUFFOLK COUNTY DEPARTMENT OF BEALTH APPROVAL
N/A
ELECTRICAL CERTIFICATE NO.
1139267
06/16/03
PLUMBERS CERTIFICATION DATED
N/A
Rev. 1/81
MAY 19 '04
12:55PM 50UTHOLD BUILDING 531 755 9502
P.l
c
Form No.6
TOWN OF SOUTHOLD
21 2004 BUILD.ING DEPARTMENT
TOWN HALL
i 765-1802
APPI;ICATIbNJR CERTIFJCATE OF OCCUPANCY
{,,"!'1-z.z.4- ~,,4'l
This apphcntion must be tilled in by typewriter or ink and submitted to the Building Department with thc following:
A. 1'ur new buDding or /lew use:
I. Fina.1 survey of propetty with accurate location of all buildings, property lines, stl'cets, and unusual natural or
topographic fentures.
2. Filml Approval frum Health Dep!. ofwBler supply and sewerage-disposal (8.9 form).
3. Approvalllf electrical install. lion from Board of Fire Underwriters.
4. Sworn statement li'om plumber certifying that the solder used in system contains less than 2110 of 1% lead.
5. Commercial building, industrial building, multiple residences and similar buildings ll1Id illStallations. a certificate
of Code Cmnplianec frolll arch itect or cnglllcer responsible t'or the building.
6. Submit Planning Board Appmval of completed site plan requirements.
B. For existing buildings (prior to April 9, 1957) non-conforming IIses, or buildings alld "pre-exilting" land uses:
1. Accurate survey of property showing all properly lines. streets. building and unusual natural or topographic
fcature..
2. A properly completed apphcal.ion alld consel11 to inspect signed by the applicant If a Certificate of Occupancy is
denied, tile Building Jnspector shall state the reasons therefor in writing to the applicant
.,
C. Fees /
1. Certiticate of Occupancy - New dwelling $25.00, Additions 10 dwelling $25.00, Altrf.!ions to dwelling 525.00,
Swimming pool $25.00, Accessory building $25.00, Additions to accessory building $25.00, Businesses 550.00.
2. CerllJicale of Occupancy or. Pre-eXistillg Building. $100.00
3. Copy of Certificate of Occupancy - $.25
4. Updated Certificatc ofOccupnncy" 550.00
5. T,:mporary Certilicate OfOl:cllpancy - Residential 515.00, Commercial $15.00
Date.
'5.'~.~4
NeVI Construchon: _.~__._ Old or Pre-existing Building: _ (check one)
L(lcatk)nofProperty:_'2'8.~?__ CCJU.r~ Qa. ~8 Co~c.\-(otq.<J~" NY llq3?
House No. Street Hamlet
OwnerorOwnersofProperty:t:\~\:.Uurz._;ru~"f'. ~o.P"(k -z..q9 ~ OI2:'Gt.l~, t-.!y \1(\171
SuffolkCountyTaxMapNoIOOO.Se.;tion o'tb _Block 000 I Lot O\q.COl
SLllxIivision .__.__ Filed Map. Lot:
Pennh No. _._kCi ~qZ_. Date of Permit. ? -I.CI . O~ Applicant:. T- M+ll.e. O~...\ ~;r-J \- CorIAIIA-
Health Dcpl. Approval: Underwriters Approval:
Planning Board Approv111: _.___
/
(check one)
Rcqueill for: TcmporlllY Certificvte. . ______ FlIlal Certificate:
~/'\.~
Fee 8\lbmitted: S __:..~___ .___._
~-l~> 1 0 r,c,~
COl3r.,11
Ap nt Signature
t-J\A~ft) ~W:\\t>,.
-r: JI10btle 'RaOJec! t-o\~&Ct-
FORM NO. 3
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
Town Hall
Southold, N.Y.
BUILDING PERMIT
(THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL
COMPLETION OF THE WORK AUTHORIZED)
PERMIT NO.
29392 Z
Date MAY
19, 2003
permission is hereby granted to:
ARTHUR V JUNGE
PO BOX 299
ORIENT,NY 11957
for :
INSTALLATION OF WIRELESS COMMUNICATIONS ANTENNAS TO AN EXISTING
MONOPOLE AND RELATED EQUIPMENT AS PER ZBA AND PLANNING AS APPLIED FOR
at premises located at
21855 CR 48
CUTCHOGUE
County Tax Map No. 473889 Section 096
Block 0001
Lot No. 019.001
pursuant to application dated MAY 12, 2003 and approved by the
Building Inspector to expire on NOVEMBER 19, 2004.
Fee $
200.00
ORIGINAL
Rev. 5/8/02
€!P ;).Cl~q;:"f'n"~"~~111~'
I!I.I!I
I BY THIS CERTIFICATE OF COMPLIANCE TH~ ',c' ! I
~ NEW YORK BOARD OF FIRE UNDERWRITERS ~
~ BUREAU OF ELECTRICITY ~
~ 40 FULTON STREET - NEW YORK, NY 1 0038 ~
~ CERTIFIES THAT ~
~ ~
~ Upon the application of upon premises owned by ~
~ {~I.t-i"J . I ~
~ EDWARD CUFF ELECTRICAL CONTR. VOICESTREAM WIRELESS ~
~ 3178 HEMLOCK FARMS 11 HIGH POINT ~
~ HAWLEY, PA. 18428, WAYNE, NJ 07470 ~
~ Located at 21855 COUNTY ROAD 48 CUTCHOGUE, NY 11935 ~
~ ~
~ Application Number: 1139267 Certificate Number: 1139267 ~
I Section: Block: Lot: Building Permit: BDC: NS11 I
~ Described as a Connnercial occupancy. wherein the premises electrical system consisting of ~
I electrical devices and wiring. described below. located inion the premises at: I
~ Outside, . ~
~ .~
~ was inspected in accordance with the National Electrical Code and the detail of the installation. as set forth below. was . ~
~ found to be in compliance therewith on the 16th Dayof June, 2003. ~
~ Name OTY Rate Rating Circuit DJ2!; ~
~~~~ ~
~ Receptacle 1 0 GFCI ~
~ Service ~
ffil 1 Phase 3 W Service Rating 200 Amperes ~
~ Service Disconnect: 1 200 cb ~
~ Meters: 1 ~
~ ~
~ ~
~ ~
~ ~
~ ~
~ ~
~ ~
~ seal ~
~ ~
~ 1 of 1 ~
I This certificate may not be altered in any way and is validated only by the presence of a raised seal at the location indicated. I
I!I.I!I
.
,
Lydia A. Tortora, Chairwoman
Gerard P. Goehringer
George Horning
Ruth D. Oliva
Vincent Orlando
Southold Town Hall
53095 Main Road
P.O. Box 1179
Southold, New York 11971-0959
ZBA Fax (631) 765-9064
Telephone (631) 765-1809
http://southoldtown.northfork.net
APPEALS BOARD MEMBERS
BOARD OF APPEALS
TOWN OF SOUTHOLD
FINDINGS, DELIBERATIONS AND DETERMINATION
MEETING OF MARCH 20, 2003
Appl. No. 5232 - Omnipoint (Owner: A. Junge)
Property Location: 21855 C.R. 48, Cutchogue; Parcel 1000-96-1-19.1
SEQRA DETERMINATION: The Zoning Board of Appeals has visited the property under
consideration in this application and determines that this review falls under the Type II
category of the State's List of Actions, without an adverse effect on the environment if
the project is implemented as planned.
PROPERTY FACTS/DESCRIPTION: The property contains an area of 14,859 sq. ft.
and is improved with a one-story metal building (auto repair shop), one-story masonry
building, an existing telecommunications monopole structure located in the rear yard.
BASIS OF APPLICATION: Building Department's September 19, 2002 Notice of
Disapproval, denying a permit under Section 100-165C to install public utility equipment
with a rear yard setback of less than 70 feet in this Light Industrial Zone District.
FINDINGS OF FACT
The Zoning Board of Appeals held a public hearing on this application on January 16,
2003, at which time written and oral evidence were presented. Based upon all
testimony, documentation, personal inspection of the property, and other evidence, the
Zoning Board finds the following facts to be true and relevant:
AREA VARIANCE RELIEF REQUESTED: A Variance is requested under Section 100-
165C to install an equipment building with a rear yard setback at 7'2" from the rear
property line. The proposed building is 10 x 17 ft. in size and will be enclosed in a chain-
link fence compound, as shown on the August 4, 2001 survey prepared by Barrett,
Bonacci and Van Weele, P. C. and site plan prepared by William F. Collins, AlA.
REASONS FOR BOARD ACTION: On the basis of testimony presented, materials
submitted and personal inspections, the Board makes the following findings:
1. Grant of the variance will not produce an undesirable change in the character of the
neighborhood or a detriment to nearby properties. The Telecommunications Law
requires co-location on existing towers. This property contains an existing tower. The
applicant proposes to co-locate an antenna in accordance with the existing law. The
need for an equipment shelter building is in support of the co-location. The existing
Telecommunications Tower sits approximately 41 feet to the rear property line, and there
is a need for this building to be as close to the tower as possible. The applicant requests
a variance to allow him to place the storage building 7 feet 2 inches from the southwest
.
.
Page 2 - March 20, 2003
Appl. No. 5232 - Omnipoint Communications
96-1-19.1 at Cutchogue
rear property line based on a survey by Barrett, Bonacci and Van Weele, P. C. dated
August 4, 2001 and a site plan prepared by William F. Collins, AlA.
2. The benefit sought by the applicant cannot be achieved by some method, feasible for
the applicant to pursue, other than an area variance. Because of restraints caused by
the Southold Landfill to the north and west and the confines of the existing tower, the
building cannot be placed in another area without a variance.
3. The variance granted herein is substantial in relation to the code requirement.
However, due to existing constraints, the storage building cannot be placed in another
area.
4. The alleged difficulty has been self-created because the applicant was aware of the
difficulty when the property was purchased.
5. No evidence has been submitted to suggest that the relief granted will have an
adverse impact on physical or environmental conditions in the neighborhood.
6. Grant of the requested relief is the minimum action necessary and adequate to
enable the applicant to enjoy the benefit of a storage building while preserving and
protecting the character of the neighborhood and the health, safety and welfare of the
community.
RESOLUTION OF THE BOARD: In considering all of the above factors and applying
the balancing test under New York Town Law 267-B, motion was offered by Member
Oliva, seconded by Member Goehringer, and duly carried, to
GRANT the variance applied for with the condition that the applicant will provide
landscaping for buffering, with five foot high arborvitae, or the like, planted four
feet apart, on the west and southwest side fence area to be continuously
maintained. The Board, however, reserves the right to review this buffering
layout if the screening is not adequately maintained by the applicant.
This action does not authorize or condone any current or future use, setback or other
feature of the subject property that violates the Zoning Code, other than such uses,
setbacks and other features as are expressly addressed in this action.
Vote of the Board: Ayes: Members Tortora (Chairwoman), Goehringer, Horning, Oliva,
ood O"oodo. Thl' 0''''01100 m, dol, ,dop~d (5-0). ~
~~ ~~~
Lydia A. rtora, Chai oman
4//103
KENNETH L. EDWARDS
MARTIN H. SIDOR
GEORGE D. SOLOMON
JOSEPH L. TOWNSEND
MAIUNG ADDRESS:
P.O. Box 1179
Southold, NY 11971
OFFICE LOCATION:
Town Hall Annex
54375 State Route 25
(cor. Main Rd. & Youngs Ave.)
Southold, NY
Telephone: 631 765-1938
Fax: 631 765-3136
PLANNING BOARD MEMBERS
JERILYN B. WOODHOUSE
Chair
PLANNING BOARD OFFICE
TOWN OF SOUTH OLD
July 17, 2006
Mr. Anthony Feliciano
Bechtel Corporation
I Huntington Quadrangle
Melville, NY 11747
Re: Site Plan inspection and satisfaction letter for Cingular Wireless (Lin Cellular)
21855 County Road 48 in Cutchogue
SCTM# 1000-96-1-19.1 Zone: Ll, Light Industrial
Dear Mr. Feliciano,
At the written request of Mike Y osua letter dated July 7,2006, for a Certificate of
Occupancy final site inspection, Planning Department staff performed a site visit on July
14,2006.
In reference to the above, the Planning Board held a work session on July 17,2006 to
review the site plan dated April 12, 2005 and site visit staff comments. The Planning
Board accepts the Arborvitaes as planted in the site landscape as described by staff. This
is to inform you that the site plan requirements have been satisfied conditional ofthe
following item:
1. As per the landscape survivability guarantee, the applicant agrees to replace any
ofthe landscaping which dies within three (3) years of planting
This letter does not condone any changes from the approved site plan and approvals from
other agencies ifrequired.
If you have any questions, please contact the Planning Board Office at (631) 765-1938
between the hours of8:00 a.m. and 4:00 p.m.
erilyn B. Woodhouse
Chairperson
r ," .'--"'-"--~'---'-
Ij~ p ~ i '
. I. ...'.
I,
, ,.
JUL25
cc:file, Building Department, Town Engineer
I l.
L__
RICHARD CAGGIANO
~LL~J.CREMERS
KENNETH L. EDWARDS
MARTIN H. SIDOR
P.O. Box 1179
Town HaIl, 53095 State Route 25
Southold, New York 11971-0959
Telephone (631) 765-1938
Fax (631) 765-3136
.
;
-
PLANNING BOARD MEMBERS
BENNETT ORLOWSKI, JR.
Chairman
PLANNING BOARD OFFICE
TOWN OF SOUTHOLD
May 13, 2003
Lawrence C. Re, Esq.
Munley, Meade, Nielsen & Re
36 North New York Avenue
Huntington, NY 11743
He: Proposed Amended Site Plan for Omnipoint Communications, Inc.
Located on the north side of CR 48, 750' west of Cox's Lane, Cutchogue
SCTM#1000-96-1-19.1 Zone: L1, Light Industry
Dear Mr. Re:
The following resolution was adopted by the Southold Town Planning Board at a
meeting held on Monday, May 12, 2003:
The final public hearing was closed.
The following resolution was adopted:
WHEREAS, Omnipoint Communications, Inc. is the lease holder and Arthur Junge is
the owner of the property known and designated as Omnipoint Communications, Inc.
Antenna Site, located on the north side of CR 48 in Cutchogue; SCTM 1000-96-1-19.1;
and
WHEREAS, this site plan for Omnipoint Communications, Inc. is to affix up to twelve
wireless telecommunications antennas to an existing monopole and install a related
equipment shelter; and
WHEREAS, this site plan was certified by the Building Department on May 10, 2003;
and
WHEREAS, the Town Engineer has reviewed the drainage calculations and the
Planning Board has accepted his recommendation for approval; and
WHEREAS, the Southold Town Planning Board, pursuant to the State Environmental
Quality Review Act, (Article 8), Part 617, declared itself lead agency and issued a
Negative Declaration on January 13, 2003; and
/.
-
Omnipoint Communications - Paqe Two - 5/13/03
WHEREAS, a variance was granted by the Zoning Board of Appeals (Application No.
5232) on March 20, 2003 to allow the placement of an equipment building at less than
the required 70 feet from the rear property line and further required additional landscape
buffering on the west and southwest side fence area; and
WHEREAS, a final public hearing was closed on said application at Town Hall,
Southold, New York on May 12, 2003; and
WHEREAS, all the requirements of the Site Plan Regulations of the Town of Southold
have been met; be it therefore
RESOLVED, that the South old Town Planning Board grant final approval on the
surveys, dated August 16, 2002 and last revised January 16, 2003, and authorize the
Chairman to endorse the final surveys subject to a one year review from the date of the
building permit.
Enclosed please find two copies of the approved site plan; one for your records and one
to be submitted to the Building Department when you apply for your building permit.
Please contact this office if you have any questions regarding the above.
Very truly yours,
~(]J~fJ]~
Bennett Orlowski, Jr. @
Chairman
encl.
cc: Building Dept.
Tax Assessors
/'
FIELD Il'lSPECTION REPORT DATE COMMENTS 'P
..JJ'"
\).Jl"'l
FOUNDATION (1ST) ~~
~::l
W"
-.--._------------------------------
::!>
:::. ~
FOUNDATION (2ND) gr~
.:;
\/\
Z
. P
\U
-
Vl'"
ROUGH FRAMING & VI ~
l"'l
PLUMBING ~.,
-.(::.
. oq
~
t'""
INSULATION PER N. Y. C?~
STATE ENERGY CODE
+
. \'
[
7/,0 ,~ r~r;? - r
/ /' :#/"a. ^ ~",.I P ,~.7
// / A 7 '/lj/ )
.
v 1./ , /'
FINAL
ADDITIONAL COMMENTS ~
~
- 0
~~
t~
-l"'l
\~
:;:O~
o .,
-
-ZO
z
) ==
~
;!
t::l
l"'l
'"
~
,..I:)
~
,
&:
,+:.
N
I
...l>
\5'-
-
,~
,
\j
~
t
---...
t:J~.'" \
, .
...
..
J '
FORM NO. I
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
TOWN HALL
SOUTHOLD, N.Y. 11971
TEL: 765-1802
BOARD OF HEALTH ...............
3 SETS OF PLANS ...............
SURVEy.................... .....
CHECK ..........................
SE?TIC FORM .. ........ ...........
NOTIFY:
CALL ..................
ApprCNed......<.. .[~.,'%.~) Pennit N:l. ..l."J.3!.?1;;..
";::~.:':.:::::::::::::::::::::::::::....... ~ ----
..........~...
MAIL TO:.... .~f}.........:.:...Ii'
..J~~~~0-?fJ..
..'td.:> ~~ Ilf ~
APPLICATION FOR BUILDING PERMIT
Date............... .,19....
INSTRUCTIONS
a. '!his application DUSt beCCJq>letely filled in by typewriter or in ink and subnitted to the Iluilding Inspector wil
I sets of plans, accurate plot plan to scale. Fee according to schedule.
b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or p.lblic
.treets or. areas, and giving a detailed description of layout of property tllJSt be drawn on the diagran ,*,ich is part of
his application.
c. The ""rk covered by this application may not be C01IreOCed before issuance of Building Pennit.
d. Upon apprCNBI of tlJis application, the Illlilding Inspector lrill issue a fuilding Permit to the applicant. Such
"eIUlit shall be kept 00 the prWses availshle for inspectiorithroughout the I""rk. . .
e. N:l building shall be occupied or used in '*'ole or. i".part. for any purpose ,*,atever until a Certificate of
Jccupancy shall have been granted by the Building Inspector. ,.
Al'PLlCATICN IS JERElIY MAlE to tbe Building Departnent for the issuance of a Building Penni t p.lrsuant to the
\1ilding Zooe Ordinance of the Town of Southold, Suffolk Cooney, New York; and other applicable Laws, Ordinances.or
(egUlations, for.tbe construction of buill\ings, ad<Iitions qralt"rations, or..for.relTOVal or denDlition, as herein
1escribed. The applicant agrees td ~ly with all applicable laws, ordinanc"s, building col\e, \lousing code, and
regulatioos, and to adnit authorized inspectors 00 premises and 'in building" for necessary inspections.
. DM ~l P.O.W.r:. CoJ~1Ji{/1Jj.).tC!.J17.LQLI/ .5:)' ::t.1lJ(!-,
(Signature of applicant, or nane, if a corporation)
'~5JAL:-JfJN.. .W&.1.} . Fh.R5/PpfJN.Cf.j N.3
-a:~iling address of. applicant) D'1051
State w.lether applicant is a.mer, lessee, agent, architect, engineer,' general contractor, electrician, plurber or builder
....................................... ./..f3:s.!5t:,.6......... ............................ ...................... ,.,.....
Nare of a.mer of premises ........ AR111.(jJ.2../;..SV.N.& '6...... ............. .. ......... ..... .......,..... .......
(as on t:h<i tax roll or latest deed)
.'
I~l~~; a corporation, signature of duly authorized officer.
a~i~~E~/!~""'"
Builders License N:l.
Plrnbers License No.
Elecrric.i8nr-:. License lb.
Otl.er Trade's License N:l. ....................
I. Wcation of land 00 ,*,ich proposed work will be done.................................. ... ..... ................. .....
. . . . . :1' .8.5 5. . (!j)tJ.1;l.T.4.. H..Of.UJ . . . .4" Y. . . . . . . . . .. . . eo. Tf5. do. .& V.E,. ../:J.f1. .1 J. qJ. 5,. . . . . . . . . . .
110use I'lnber Street llanlet
Cooney Tax Map N:l. IlXXl Section.. R tP.......... Block ...;i........... Lot . .J8.. J...:......
Subdivision...................................... Filed Map N:l. ........... .... ILot .............,.
(Na:Ie )
2. State existing use and occupancy of premises and intended use and occupancy of pro'IPosed construction:
a. Existing use and occupancy .:Jd.JDu:i1'.iBll}.1 !R16LJIJ-.W//?i;I.'c.5.S..llT.Lf.,t:t':l..C~MI(J.fJJJ.'/'(J.l:lrIO^,5
FA(!.II.../Ttj 7"
b. Intended use and occupancy ... .:altJY.l.b..f.t.5.. ./}(3Ql[f,. ..... ........ ....... ....... .................
..
..
..
(
';':'~
.~'...._'.. ..
J.
I.
tJ.1ture of work (dJeCk "jdd, applicable): ~ l\JiIdlng .......... Mditlon 11.:'....... Alteration .v.(....,.
llepair ............ llemJval ............. llennlition ............ Other Work ..................................
f . 0 . ' (Description)
Est inEted Cost .. 5 ~ 0..00. { . ~ .. .. .. . fee ............................:...........,.....
(to be paid on filing this nppliCtltion)
If ck",lIing, fUlUer of (J.oelling .mits ..N.j.P.r.... li.llber of d\",lling ,mits on ench noor .t-!(fI.........
If garage, (Ulber of enrs ... ..Nltt...........................
If husiness,canrercial or mi>al occupancyJ. specVy nature and extenUlf each I:y]1\! oLuse-k.l.7...1 00.%.....
.. . . . J 5-IV'~ lV1,fj.~/-- R,L.D &.' F'<..OUJ-IO~~'/~e~'2..'D'!5:j :{>J/Jf:,-4.J.,;;"
Dnrenslons of exlstmg atnx:tures, If any: Pront.. .IPi.......... Rear /~............ Depth 0/"..............
Beight /.0.5. ~.~ . ':l.'!...... .... lblher of Storiea .. .fIJ.{. ft.... ...... .... - M OAJ{9POL-'0
Dimensions of same structure ~tll alterations or additions: Front ............... Rear .0. ............
Bepth .................... Ueight .................... lb11>er of Stories ............... &"A1Y1t A-:5 MtJi/&
Oill~nsions of entire new constructioo: Front... /.0.'........... Rear ..., 0. ~....... Depth . ..~C!. ~.....
1leilN ~ ~ . r.Wf!. f.,. .......... lini>er of Storiea .......... ~....... H'
She of lot: Front 1.(09;7../.7......... Rear ./B.BR.lfJ........ Depth .~.6:J.:. ?f.9.....
Oate of Purd18"" ......Ai .l'r......... Nm-e of Fo~r (\mer ..I,), If\. ... . .... ..... .. ..... ... ...... .. .
Zone or use district in ~lidl pranises are situated t..l. -:-. kU],f/ r. ..:1J.JbU5.rlJ.l.lI-.l......... ... .... ..... ... .... ..
~- sed " 1 . 1 . . 1" 10
l~S propo construct1on VIQ ate any zonIng sw) ordInance or regu atlon: ...PVJ..................
Will lot l>e regraded ..!Y./ 11............ will excess fill he reroved fran preniscs: YES -r- NJ
. A - . ...,-: . r-I 1'H flJJREf:,tJPO/6') Z1?,/:
Nares of <Mner of prenlSCS Wa{t:f.(..jI2.. j", ..J().Il1.(}:~ Mlreaa OJ/3J.. .5. ..~1-. n.'I:iXCf44 PI1Gne No. .1'7. ~(p5.5.
. ../ f 1 lo.-L1&(!I-IN()'-'P,{ls'i. Mille;. tp::,/: .
No'll" of Arcllltect\N.LL/.J.Mv.\.. .Qou,/.Ab,.AuL... Mdress SEIf.r/.U:t.-r;N.V..Ll'l.B:1... fllOtlC No~r:j.<j}4f5Fi.
1.
l.
I.
tl<:Jn:?; of Caltractor ............................0...... J\dOress .............................. .I1lOne th.
J. Is this property within 300 feet of a tidal wetland1 * yr,s .......... NJ.. v.:'.....
*IF YES, romun TIll'! TRUSlEllS illlMIT Ml\Y m REQJIrnm.
PLOT DIAGRAM'
locate clearly and distinctly all buildings, ...tlether.exiating or proposed, and indicate all set-back dilrensions
ruD property linea. Give street and block l'UIher or description according to deed, and ahow' atreet nm-es and indicate
bether interior or corner lot.
PI.- EI+S8
~~ [, A-r"fp,(jH[;(j H.fg./IJ~,
.'
. }Je- 'S~(Set
''A'IE (XI U~! y{)Ul:,
U'
JJNIY a' .. .1\.1.01'\.. .. .. .. .. .. ..
.Kl.v:LJJ.(b.R..l.'CtWQL..l)J!.~.r.\;~"::.I~h..l>einll dilly awonl, deposcs and says that he is tI>e appliCtlllt
'!are of individual signing contract) . . "
JOVe rmred, ON Bt.14j~l-.F DF OiY\llJli4DIJL:lT COIHR'HW\.Jl Q../4.-,-tOllJ"Sj :r:111e"
, i. llle .......... L f., .5.:5. E:..6. .. .. . ~ .. . .. .. .. .. . .. .. .. . .. .. . . . . . . .. .. .. . .. .. . . .. .. . . . . .. .. .. . . .. .. .. . . .
(Contractor, ngent, cor[XJrate officer, etc.).
55
"''\I
r said (Yller or Q!..1T)E!rs, nod is duly authorized to perronn or have perfonretl Ule said work and to rmke and fi le thl!>
[Jplication; that all statenents ccmtained in this application are true to U,e l>est of his kn=ledge anct'\><i!.ief; and
hat the IoIOrk wi 11 be per[on~ in the '''''ruler set Forth in U,e application filed therewith..
~rn to before ne this
. .........IS.~'...day of S?p.t~d.'r:......wq.c:~~.
Notary i'lIblic .~~ ~...............
JOHN P.~
""'T AI!V PUllUC ~., JEIlSEY
~omrnJsslon ExPhIl2/1512OO5 .
.((~.~~.......'
;rs;~I:ure of ^ppllcant) .
OCCUPANCY OR
USE IS UNLAWFUL
WITHOUT CERTIFICATE
OF OCCUPANCY
LOCATION MAP
" ""':,
//
,'/
'<'-.
" '
""'
~'..'-
I"~::::~~:<
:~
o\;?<.t,."
"' ,
,
>,
, </:/
I'~ '\
,
~4:
'-, / ""~*'
~Aif)
",-",,~~~,
ehogue Station
~
KEY MAP
"":
,~", "1:</ "-;;;~,...".....;.....
.~~;,.:./__ ' ~,_,~.;-_ "_,'. e.-
L ,--.- ~ ,-'~" >':~7f:"-
}\~" ->'.~__;c;-, -: "f~:__.~
~1Eli;'-.;;;.J/<' ".t_..,..,,~.._
...,..ZiIdI_"
"--. .,-..""",-,
. .,\ . .~.,i-,. -._ "" j+
.~'""""':, c:"."""' """}";~;""'""",_".. --.. f4~:r:-."" 3,
\' -:.:t,')~~"l,_~'PL_~...6:::';"'(,
" _ c,' "{/;',
~~~~ .~--~~- ~~'
.~~.'" , ~cr~, }:~rN(JDORTH
,: ,~" "7,: , :"
DIRECTIONS
SITE
I
"
~<
D1RFCTION~ FROM
LONG ISLAND EXPRESSWAY EAST TO THE END. CONTINUE EAST ON ROUTE 58, AS IT
TURNS INTO ROUTE 25. STAY ON ROUTE 25 INTO LAUREL. FOLLOW SIGNS TO HEAD
NORTH TO TRUCK ROUTE 25 ON ALDRICH LANE. AT THE END Of ALDRICH, MAKE A
RIGHT ONTO TRUCK ROUTE 25/ROUTE 48/S0UND AVENUE EAST. CONTINUE EAST FOR
5.5 MILES THE MONOPOLE IS ON YOUR LEFT. YOU HAVE TO MAKE A U-TURN AT
THE NEXT BLOCK TO TURN AROUND INTO BUILDING.
FLOOD ZONE tv/4
COMPLY WITH CHAPTER" 46"
FLOOD DAMAGE PREVENTION
SOUTHOLD TOWN CODE.
=
COMMERCIAL TRAFFIC IS ~ PERMITTED ON PARKWAYS. VERIFY ALL ROUTES.
SECTION: 096 BLOCK: 1
ZONING: L1, liGHT INDUSTRIAL
LOT: 19.1
LATITUDE:
LONGITUDE:
W 72' 29' 821"
BURDING DPPr, NOIl'S
LOCATION OF EQUIPMENT:
EQUIPMENT SQUARE FOOTAGE:
CONCRETE PAD INSIDE COMPOUND
120 SQ.FT.:f:
CElL 'fYPIl;
EQUIPMENT:
ANTENNA:
srrn INFORMATION'
PROPERlY CONTACT:
LAND OWNER:
(3) NORTELL 512000 EQUIPMENT CABINETS
(12) EMS RR-65-19~02
(631) 804-7021 MATT BARTLETT
(516) 250-6989 ARTHER JUNGE
UTILITY CONTACT:
APPLICANT:
lJ'SSEE:
(516) 792-7112 LlPA
OMNIPOINT FACILITIES NETWORK 2, LLC
OMNIPOINT FACILITIES NETWORK 2,
PROJECT MANAGER:
RF ENGINEER:
LLC, 4 SYLVAN WAY, PARSIPPANY NJ 07054
KEVIN GRISWOLD (973) 686-6509
NAMIT SHARMA (973) 978 5843
DRAWING INDEX
JJMJ. I DltAWINCJ'IInJ!
T -1 I TITLE SHEET
AR<>IIl1lCIllIl
A-l ARCHITECTURAL SITE PLAN
A-2 WEST ELEVATION AND SITE DETAILS
A-3 ENLARGED PART SITE PLAN &: DETAILS
A-4 TYP. CABINET &: ANTENNA PLATFORM DETAILS
A-5 DETAILS
A-6 ANTENNA SCHED, B.O.M. &: ROUTING SCHEMATIC
IIlJlCIRrAL
E-1 GENERAL ELECTRIC NOTES AND SYMBOLS
E - 2 [LEC SERVlCE PLAN, RISER DIAGRAU AND 8TS RISER DIAGRAt.4S
E-3 EQUIPMENT GROUNDING PLAN AND DETAILS
[-4 GROUNDING SHEMATIC AND DETAILS
[-5 ANTENNA AND CABLE GROUNDING & WATERPROOFING
""""""'11ON
SC 1 SPECIFICATION
SC 2 SPECIFICATION
SC 3 SPECIFICATION
SC 4 SPECIFICATION
SC 5 SPECIFICATION
SC 6 SPECIFICATION
I INII1AL """""" I NllIlAm'IT IISUANC
I 08/16/02 I 2 I 01/17/03
08/16/02 2 01/17/03
08/16/02 ^ 01/17/03
08/16/02 2 01/17/03
08/16/02 . 01/17/03
08/16/02 2 01/17/03
08/16/02 2 01/17/03
08/16/02 I. 01/17/03
08/16/02 2 01/17/03
08/16/02 2 01/17/03
08/16/02 2 01/17/03
08/16/02 2 01/17/03
2
2
2
2
2
2
"*
QPE!CE -+
201/17/03 REV. PER TOWN okHKl8L
1 09/03/02 ISSUED FOIl FLHG
o 08/16/02ISSU(1)FOll?llEUWlHAR't'RE.VIlW
NO. DATE OESCRIPTlON
L.T. NJA.
S.M. N.lA.
S.M, N,lA.
R CHI(
y "
"lE
APPROVALS
SIGNATURE
VOICESTREAlA
O'/INER,lt.ANOllRO
LEASING/SAC
RFENGINEER
ZONING
CONSTRUCTION
WILLIAM F, COLLINS, AlA
A R. CHI TEe T S, LLP
--- -
1)-1 'JBOD<<)l.()(JY DIUVB SETAlJEBT. NY D7lJ
VOICE . o.--Q&--84,50 FAX . 63l-Q9-8ol9J
. t t ,;/ Iwww.wfeata.co .
PROJECT # 02-4900
~~M~~~f.~~~ct
osanogellllOf
Orrlnf;loiI1rdlisNelIlrl:2,llC.
.4 Sylvan Way, Ponlppony, NJ 07054
Omnipoint Communicotions Inc. is 0 subsidiary
of VoiceSlream Wireless Corporation
SITE INFORMATION
CUTCHOGUE
71855 COUNTY ROAD 48
CUTCHOGUE, N,Y, 11935
L1-13-544-A
DESIGN TYPE
NEW BUILD
COLOCA TION MONOPOLE
SHEET TITLE
TITLE
SHEET
SHEET NUMBER
REV,
T-1
2
1::LQIE.;
INFORMATION SHOWN HEREIN IS BASED UPON A
SURVEY PREPARED BY: BARRETT, BONACCI &
VAN WEElE, P.C. CIVIL/ENGINEERS/SURVEYORS/
PLANNERS, 175A COMMERCE DRIVE HAUPPAUGE,
N,Y. 11788 (631) 435-1022 (ON AUGUST 4,
2001 PROJECT NO: AD10670)
EXISTING FENCED COMPOUND.
EXISTING MONOPOLE.
EXISTING TREE LINE.
NEW OMNIPOINT
COMMUNICATIONS EQUIPMENT
WITHIN NEW CHAINlINK
FENCE COMPOUND. SEE
ENLARGED EQUIP. PLAN
SHEET A-3.
FUTURE NEXTEL EQUIPMENT BY
OTHERS.
( SECTOR 'c'
270'
Co-/,
z.,-1'~
IS~
0-1'0)
~
(10) NEW 3'~x5' HIGH
ARBORVlTlES EVERY 4'
@
PROPERT'( LINE ~I
1/ L U>.NOSCAPE
BULL BOX. TYP. I r
I
<~
" '-ll'.
,
EXISTING UNDERGROUND DRAINAGE PIPING.
EXISTING ELEC/ TELCO
UNDERGROUND.
8
,.
2.
3.
~ 4.
S.
~ 6.
7.
B.
~ 9.
10.
11.
ARCHITECTURAL SITE PLAN
SCALL 1" = 40'
EXISTING UTILITY POLE.
GENERAL NOTES:
1. ALL WORK SHALL BE DONE IN STRICT ACCORDANCE WITH PROVISIONS OF LOCAL, STATE, AND FEDERAL,
LAWS, ORDINANCES, AND REGULATIONS WHEREVER APPLICABLE.
2. EACH CONTRACTOR SHALL BE HELD TO HAVE VISITED THE SITE AND TO HAVE VERIFIED ALL EXISTING
CONDITIONS PRIOR TO SUBMISSION OF BID.
} IN ALL CASES, DRAWINGS SHAll NOT BE SCALED FOR INFORMATION. FIGURED DIMENSIONS AND
CONDITIONS MUST BE VERIFIED IN THE FIELD.
4. CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL FIELD DIMENSIONS AND JOB CONDITIONS,
AND SHALL NOTIFY THE ARCHITECT OF ANY DISCREPANCIES, CONFLICTS, AND/OR OMISSIONS WHICH
WOULD INTERFERE WITH THE SATISFACTORY COMPLETION OF THE WORK. SHOULD HE FAIL TO FOLLOW
THIS PROCEDURE AND CONTINUE WITH THE WORK, HE SHALL ASSUME ALL RESPONSIBILITY AND LIABILITY
ARISING THEREFROM.
5. ALL ITEMS OF WORK IDENTIFIED ON THE DRAWINGS BY NAME, NOTE, OR MATERIAL DESIGNATION ARE
NEW, UNLESS OTHERWISE NOTED.
6. ALL NEW MATERIALS AND INSTALLATIONS SHALL BE IN ACCORDANCE WITH THE MANUFACTURERS LATEST
PRINTED SPECIFICATIONS, AND WITH ALL APPLICABLE CODE REQUIREMENTS.
7. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH BEST STANDARD TRADE PRACTICES. EACH TRADE
SHALL COOPERATE WITH OTHER TRADES TO FACILITATE JOB SCHEDULING AND COMPLETION.
8. PROPRIETARY NAMES IDENTIFYING ITEMS OF WORK ARE USED TO DESIGNATE THE STANDARD OF
CONSTRUCTION. ITEMS OF EQUAL QUALITY MAY BE SUBMITTED FOR THE ARCHITECTS REVIEW AND
APPROVAL.
9. EACH CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO ADJOINING REMAINING AREAS AS A
RESULT OF HIS WORK, AND SHALL REPAIR DAMAGED SURFACES TO THEIR PRE-EXISTING CONDITIONS OR
AS MAY BE REQUIRED TO COMPLETE THE ENTIRE SCOPE OF THE WORK.
10. ALTERATIONS TO EXISTING WORK SHALL BE PATCHED AND FINISHED, AS NECESSARY, TO MATCH EXISTING
CONTIGUOUS SURFACES OR NEW FINISHES SHOWN.
11. AT THE COMPLETION OF EACH WORKDAY, EACH TRADE SHALL BE RESPONSIBLE FOR CLEANING UP THEIR
WORK. RUBBISH REMOVAL SHALL BE DONE IN A DUST INHIBITIVE FASHION, AND THE JOB SITE SHALL BE
FREE OF ALL DEBRIS AND BROOM CLEAN UPON COMPLETION.
12. CLEAN ALL FLOORS, WALLS, DOORS, MISC., GLASS, ETC. LEAVING JOB FREE OF DUST AND DEBRIS,
PRIOR TO PROJECT COMPLETION.
13. EXISTING EQUIPMENT AND MATERIALS TO BE REMOVED, WHICH ARE NOT REQUIRED TO BE RELOCATED OR
RETAINED BY THE OWNER, SHALL BECOME THE PROPERTY OF THE CONTRACTOR AND BE REMOVED FROM
THE PREMISES.
14. INDICATIONS OF WORK TO BE REMOVED ARE GENERAL ONLY, AND ARE NOT INTENDED TO SHOW ALL
ITEMS WHICH MAY REQUIRE REMOVAl. SUCH ITEMS SHALL BE REMOVED, RELOCATED, AND/OR
REINSTALLED, AS REQUIRED FOR INSTALLATION OF NEW WORK.
15. THESE DOCUMENTS DO NOT AUTHORIZE DETERMINING THE PRESENCE, NOR THE REMOVAL OF ASBESTOS
OR OTHER HAZARDOUS MATERIALS. IF DURING THE COURSE OF THE PROJECT, ASBESTOS OR OTHER
HAZARDOUS MATERIAL CONTAMINATION IS SUSPECTED, THE CONTRACTOR SHALL NOTIFY THE CARRIER'S
PROJECT MANAGER WITHIN 24 HOURS. CONTRACTOR SHALL SUSPEND WORK IN THE AFFECTED AREA
UNTIL SUCH A TIME THAT SAID AREA IS CERTIFIED CONTAMINATION-FREE. IN THE INTERIM, THE
CONTRACTOR SHALL ENDEAVOR TO RESCHEDULE WORK TO AREAS UNAFFECTED BY SUSPECTED
CONTAMINATION IN ORDER TO MINIMIZE DELAY TO THE PROJECT SCHEDULE.
16. ALL MECHANICAL AND ELECTRICAL WORK SHALL BE IN FULL CONFORMANCE WITH N.Y.S. UNIFORM FIRE
PREVENTION AND BUILDING CODE, AND ALL OTHER APPLICABLE CODES AND REGULATIONS.
17. ELECTRICAL WORK SHALL BE INSTALLED BY AN ELECTRICIAN LICENSED IN SUFFOLK COUNTY IN
ACCORDANCE WITH NEW YORK STATE AND NATIONAL ELECTRICAL CODES. A NEW YORK BOARD OF FIRE
UNDERWRITER'S CERTIFICATE SHALL BE OBTAINED FOR ALL ELECTRICAL WORK, AND SUPPLIED TO THE
OWNER AND ARCHITECT.
lB. PROVIDE ANY AND ALL TREATED WOOD BLOCKING/BACKING OR 14 GA. GAlV. FLAT STOCK BACKING AS
REQUIRED TO ENSURE PROPER AND ADEQUATE SUPPORT (IN COMPLIANCE WITH NEW YORK STATE
BUILDING CODE MINIMUM LOADING REQUIREMENTS WHERE APPLICABLE) OF VARIOUS ITEMS INCLUDING,
BUT NOT NECESSARILY LIMITED TO, HANDRAILS, CABINETRY, SHELVING, HANDICAP GRAB BARS, TOILET
ACCESSORIES, CABLE TRAYS, CONDUITS, ETC.
19. ADA COMPLIANCE: THE FACILITY IS A NORMALLY UNOCCUPIED MOBILE RADIO FACILITY.
GENERAL SITE NOTES:
ALL SITE WORK TO CONFORM TO THE LATEST TOWN OF SOUTHOLD PLANNING BOARD SPECIFICATIONS AND
STANDARDS.
'DEWATER' All TRENCHES AS REQUIRED DURING INSTALLATION OF ALL FOOTING AND FOUNDATION TO
ENSURE PROPER DEPTH AND STRUCTURAL INTEGRITY OF CONCRETE.
THE DEVELOPER SHALL COMPLY WITH APPROVED WORKING DRAWINGS AND REQUIREMENT SHEETS. NO
DEVIATION WILL BE PERMITTED EXCEPT BY WRITTEN APPROVAL OF TOWN SOUTHOLD PLANNING BOARD.
COMPACTION UNDER STRUCTURES, BUILDING SLABS, STEPS, PAVEMENTS AND WALK WAYS SHALL BE 95%
MAXIMUM DRY DENSITY, ASTM 0 1557. COMPACTION UNDER LAWNS OR IN UNPAVED AREAS, 85%
MAXIMUM DRY DENSITY, ASTM 0 1557.
ALL ELECTRIC AND TELEPHONE SERVICES SHALL BE INSTALLED UNDERGROUND,
ELECTRICAL CONTRACTOR TO TONE PATH OF EXISTING CABLE AND PROVIDE MARK-OUTS. HAND EXCAVATE
NEAR ANY UNDERGROUND PIPES, UTILITIES, OR STRUCTURES.
VERIFY LOCATION OF ALL UNDERGROUND UTILITIES WITHIN AREAS OF WORK. PROVIDE ALL NECESSARY
MEANS OF PROTECTION OF SAID EXISTING UTILITIES AS REQUIRED TO ACCOMMODATE NEW WORK.
COORDINATE ALL REQUIRED RELOCATION WORK WITH THE AFFECTED UTILITY PROVIDER.
All WASTE MATERIAL INCLUDING RUBBISH, STUMPS, DEBRIS, ETC., SHALL BECOME THE PROPERTY OF
THE CONTRACTOR AND BE REMOVED FROM THE SITE.
CONTRACTOR TO MINIMIZE THE DISTURBANCE TO EXISTING SITE DURING CONSTRUCTION. EROSION
CONTROL MEASURES, IF REQUIRED DURING CONSTRUCTION, SHALL BE IN CONFORMANCE WITH THE LOCAL
GUIDELINES FOR EROSION AND SEDIMENT CONTROl. ALL CONCRETE USED FOR ON-SITE CONSTRUCTION
SHALL BE AIR ENTRAINED, MINIMUM 4,000 PSI AT 28 DAYS.
IF EXISTING GRAVEL BEDDING IS REMOVED, STOCKPILE, AND RESPREAD AS REQUIRED TO ACCOMMODATE
NEW WORK. RESTORE LANDSCAPE FILTER FABRIC AS WELl. PROVIDE ADDITIONAL MATERIALS AS REQUIRED.
FINAL GRADE SHAll SLOPE AWAY FROM THE PCS EQUIPMENT AND TOWER AREAS.
201/17/03
109/03/02
0011/16/02
NO, DATE
REV, PER TOWN h T-MOBllf
lSSum fOR FILING
Issum FOR PRWI,lINAA'\'REV1EW
DESCRIPTION
LT. N.M
S.l.!,N,l.!.
S,l.!. N.M
DRW CHK
BY BY
DATE
APPROVALS
SIGNATURE
VOICESTREAM
O\IIN(R/l~t(lLO'lO
LEASING/SAC
RF ENGINEER
ZONING
CONSTRUCTION
WILLIAM F. COLLINS, AlA
ARC HIT BeT s. LLP
D-I 'IBCJD<<)l.OGY DIUYB SETADmr, NY U7J3
VOICB . 63l-6I9-845D FAX I 631~
.tt,:llwww.wfca.a.c:..
PROJECT # 02-4900
~~M~~C~~~~~ct
asooagenlfor
llmnipoinlraciiliesNel1M:2,LLC.
4 Sylvan Way, Parsippany, NJ 07054
Omnipolnt Communicotions Inc. is a subsidiary
of VoiceSlream Wireless Corporation
SITE INFORMATION
CUTCHOGUE
71855 COUNTY ROAD 48
CUTCHOGUE, N.Y. 11935
L1-13-544-A
DESIGN TYPE
NEW BUILD
COLOCA TION MONOPOLE
SHEET TITLE
ARCHITECTURAL
SITE PLAN
SHEET NUMBER
REV.
A-1
2
NOTE:
DRAWINGS DEPICT THE INSTALLATION OF
NEW ANTENNAS, MOUNTING FRAMES,
CABLING, HANDHOLES ETC. THAT ARE TO
BE PLACED ON AN EXISTING MONOPOLE
STRUCTURE. A STRUCTURAL ANALYSIS
SHALL PERFORMED BY OTHERS, PRIOR TO
THE iNSTALLATION OF NEW ANTENNA
COMPONENTS, AS REQUIRED TO EVALUATE
THE STRUCTURE FOR ADEQUACY OF
SUPPORT FOR THE NEWLY APPLIED LOADS
OF THE NEW EQUIPMENT. ANALYSIS SHALL
BE PERFORMED BY A NEW YORK STATE
LICENSED PROFESSIONAL ENGINEER. THE
EVALUATION REPORT AND REMEDIAL
DESIGN IF REQUIRED SHALL BE SIGNED
AND SEALED. OWNER SHALL BE
RESPONSIBLE FOR VERIFYING STRUCTURAL
ADEQUACY OF THE EXISTING MONOPOLE.
rlr..10S'-8"j: AGL
~ T.O. EXISTING MONOPOLE
~ 102'-8"j: AGL /
V It OF EXISTING ANTENNAS
93'-0".:.1: AGL
T.O. NEW DMNIPOINT
ANTEN NAS
90'-O"j: AGL
"" RAD lk NEW OMNIPQINT ANTENNAS
~80'-O".:.I: AGl
Ii OF EXISTING
NEXTEL ANTENNAS
NEW 6' ~O" CHAIN LINK
FENCE WITH 4'-0" WIDE
LOCKABLE SWING GATE
TO MATCH EXISTING. SEE
DETAIL 3jA-2.
o
WEST ELEVATION
SCAlL l/S" ~ "-0"
EXISTING 105'-8" MONOPOLE BY OTHERS.
EXISTING SECTOR ANTENNAS TO REMAIN.
(12) NEW OMNIPOINT ANTENNAS ON
T-ARM FRAME. SEE DETAIL 2/A-.4
EXISTING ANTENNA SECTOR BY OTHERS.
EXISTING EQUIPMENT BEYOND.
(3) NEW DMNIPOINT EQUIPMENT
CABINETS SET ON CONCRETE PAD.
NEW ELECTRICAL METER, DISCONNECT
SWITCH, ELECTRIC AND TElCO PANELS
MOUNTED TO UNlSTRUT RACK SEE DETAIL
2 SHEET A-3.
NEW GPS MOUNTED TO NEW METER,
DISCONNECT SWITCH. SEE DETAIL
2/A-3
FUTURE EQUIPMENT BY OTHERS.
O'-O"~
GRADE
NOTE:
NEW ARBORVITIES NOT SHOWN FOR
CLARITY.
RESTORE TRENCHED AREA TO EXISTING
OR BETTER CONDITION
COMPACTED SUB-GRADE,
COMPACT IN 6" LIFTS
6"WIDE METAL CORE,
UNDERGROUND WARNING
TAPE PRINTED WITH "CAUTION
BURIED UTILITY LINES"
2,12 CCA.04 TREATED . II-II
CONTINUOUS PLANKS P~AINTED :
RED. NUMBER OF PLANKS AS -1_
REO'D WIDTH OF TRENCH. _ - _
UNDISTURBED EARTH 'I I111
WASHED SAND COMPACTED '11-
IN 6" LIFTS. - I
PVC CONDUIT, TYP. COORDINATE
TYPE, SIZE AND NUMBER OF
CONDUITS WITH INFORMATION
SHOWN ON ELEC. DRAWINGS, AND
WITH ELECTRIC AND TELEPHONE
UTILITY COMPANIES.
o
I
'-
0,
tmI..E.;
HAND EXCAVATE WITHIN 5' OF EXISTING
UNDERGROUND UTiliTIES (V.I.F.) MAINTAIN
18" MIN. CLEARANCE. CONTRACTOR TO
MAKE ALL PVC JOINTS WATERTIGHT. TEST
PRIOR TO BACKFILliNG.
0~}~'[T02~E1~~,HING DETAIL
4' 0"
CLEAR OPENING
4' -0" GATE WITH
PAD LOCK
PROVISIONS.
1" CROWN
II
I II
II
LLJ
II
I II I
lJ
L-O~J
GALV. CAP
TOP BRACE RAIL
LINE POST
STRETCHER BAR
DIAGONAL ROD
W / STEEL
TURNBUCKLE
BOTTOM TENSION
WIRE
T.O. FIN CURBI
GRAVEL BED
1 1/2" MAX
CLEARANCE
FROM GRADE
lYPIr.AI WOVFN WIRF fFNCING NOTrS
(INSTAlL FENCING PER ASHol F-567, SWING GATES PER ASTM f- 900)
1. GATE POST. CORNER, TERt.lINAl OR PULL POST 2 1/2"iJ SCHEDULE 40 fOR GATE WIDTHS UP THRU 6
FEET OR 12 fEET FOR DOUBLE SWING GATE PER ASTM-tl083.
2. LINE POST: 2". SCHEDULE 40 PIPE PER ASTM-fl083.
3. GATE fRAl.lE: 1 1/2". SCHEDULE 40 PIPE PER ASTI,4-f1083.
4. TOP RAIL &: BRACE RAil: 1 1/2". SCHEDULE 40 PIPE PER
5. fABRIC: 12 GA. CORE WIRE SIZE 2" MESH, CONFORI,4ING TO ASTI,4-A.392.
6. TIE WIRE: IolINII,4U1,4 11 GA. GALVANIZED STEEL AT POSTS AND RAILS A SINGLE WRAP Of FABRIC TIE
AND AT TENSION WIRE BY HOG RINGS SPACED MAX 24" INTERVAlS.
7. TENSION WIRE: 7 GA. GAlVANIZED STEEL.
8. GATE LATCH: 1-3/8" 0.0. PLUNGER ROO W/ MUSHROOM TYPE CATCH AND LOCK. KEYED ALIKE FOR
AlL SITES.
9. HEIGHT.. 6' VERTiCAl (MATCH EXISTING)
CHAIN LINK FENCE DETAIL
SCALE, 1/2" = 1'-0"
, 01/17/03 R[V. P{R TOWM .. T-l~otlllE LT. N.Iol.
, 09/03/02 ISSUEOfOllflllt<<; S" ""
0 08/16/02 ISS[,{O fOR PllElMtwlY REVIEW S.M. ""
"0. CAn: DESCRIPTION 0~'W1\ C"'
"
APPROVALS SIGNATURE DATE
VOICESTREAl,I
OWNER,t.'.NOLORD
LEASING/SAC
RfENGINEER
ZONING
CONSTRUCTION
WILLIAM F. COLLINS, AlA
ARC HIT E C T S. LLP
IH 1llCHNOLOGY DRIYB SBrAJ.JJarr, NY D7J3
VOICE ' fi3l--6I9--MSO FAX ' l5Jl-61&-84551
.tt,;//...w...,...feata,e..
.-~~~~,
<<ft-'" '-,
~'
'I:'V)~_ IV';';''''''''
~/;
ft~I' ...::' WV-t
ft" '. 1/
. ,'\ '-',~~,--, -- -
",
---
PROJECT 1/ 02-4900
~Omnipoint
~ COMMUNICATIONS INC.
os on oqenI for
Onripoinl Focllies Network 2, LLC.
-4 Sylvan Way, Parsippany, NJ 0705-4
Omnipoinf Communications Inc. is a subsidiary
of VoiceStream Wireless Corporation
SITE INFORMATION
CUTCHOGUE
71855 COUNTY ROAD 48
CUTCHOGUE, N.Y. 11935
L1-13-544-A
DESIGN TYPE
NEW BUILD
COLOCA TION MONOPOLE
SHEET TITLE
WEST ELEVATION
& SITE DETAILS
SHEET NUMBER REV.
A-2 2
(12) NEW OMNIPOINT ANTENNAS
ON T-ARM FRAME. SE DETAIL
2/A-4 AND 3/A-4.
/
EXISTING MONOPOLE.
EXISTING 6'-0" HIGH BARBED
WIRE CHAINLlNK FENCE COMPOUND
WITH 12'- D" WIDE DOUBLE GATE
TO REMAIN.
NEW ELEVATED CABLE TRAY TO
ROUTE ANTENNA CABLE FROM NEW
EQUIPMENT TO EXISTING
MONOPOLE. SEE DETAIL l/A-S
AND 2/A-5.
~ EXISTING EQUIPMENT ~
" TO REMAIN.
EXISTING MONOPOLE
FOUNDATION BELOW.
EXSITING FENCE TO REMAIN.
NEW ELECTRICAL METER,
DISCONNECT SWITCH, ELECTRIC AND
TELCO PANELS MOUNTED TO
UNISTRUT RACK.
(3) NEW OMNIPOINT EQUIPMENT /
CABINETS MOUNTED ON 10'X 20'
POURED CONCRETE SLAB. SEE
DETAIL 3/A-3.
/
NEW OMNIPOINT
GPS ANTENNA
FASTENED TO
UNISTRUT RACK
/
/
/
II
II
II
II
II
II
II
II
II
II
/
/
/
EW 6'-0" HIGH CHAIN
LINK FENCE COMPOUND
WITH 4'-0" WIDE
LOCKABLE SWING GATE
MATCH EXISTING. (SEE
DETAIL 3/A-2.)
/
/
/
(10) NEW 3'0XS' HIGH
ARBOOVITIES EVERY 4'
(SEE DETAIL 3/A-S.)
8
~
ENLARGED EQUIPMENT PLAN
SCALE, 1 /8" ~ 1'-0"
NEW GPS ANTENNA FASTENED TO VERTICAL BRACE.
6"x3"xJ/8" GALV. STEEL ANGLE WITH (1) 1/2" GALV.
STEEL V-BOLTS MOUNTED TO UNISTRUT FRAME.
NOTE:
UNISTRUT P1000 EQUIPMENT RACK TO BE
HIGH STRENGTH HOT DIPPED GALVANIZED
GALV. POST CAP
:t3'-O" OR AS REQUIRED
ATTACH UNISTRUT TO POST
WITH 3/8"0 GALV. U-BOLTS.
PROVIDE ALL NECESSARY
HARDWARE.
NEW ELEC RIC
PANEL & ELC
2"0 GALV. SCHEDULE 40
PIPE TO BE WELDED TO
12"X12" GALV. STEEL BASE
PLATE.
UNISTRUT P1000 BRACE
(AS REQUIRED)
NEW 8" POURED
CONCRETE EQUIPMENT PAD.
SEE DETAIL 3/A-3 FOR
MORE INFORMATION.
II
I
II
I
I
I
I
I
I
I
"
'01
.,/ .'
,,'
12"X12"X5/8" GALV. STEEL BASE
PLATE EXP BOLT TO NEW CONCRETE
PAD WITH (4) '/8< S/S EXPANTION
BOLTS WITH .1" EMBEDMENT,
ETER, DISC,
BOXES
NEW GPS
COAX
CABLE.
1 4"
TYP.
.... ......
'.
in
. , ;.,
UNISTRUT TELCO ELEC RACK DETAIL
SCALE'3/4" ~ 1'-0"
;"
o
w
o
w
LAYER OF WWF 6"X6"-10/10 HAUNCH.
8" THICK, 4000 PSI 028 DAYS
AIR-ENTRAINED POURED CONCRETE PAD
WITH HAUNCH AT PERIMETER.
'/4" CHAMFER (TYP)
EXISTING GRADE. REPLACE/RESTORE
3/4" STONE GROUND COVER ON
FILTER FABRIC.
-PROVIDE (4) CONTINUOUS NO.6
REBAR, TOP AND BonOM.
- PROVIDE #3 REBARS 0 24" O.C.
6" THICK LAYER OF COMPACTED SAND
OR GRAVEL BASE
COMPACT EXISTING SUBGRADE
POURED CONCRETE EQUIPMENT PAD DETAIL
SCALE'3/4" ~ 1'-0"
01/17/03 REV. PER TOWN a: l-t.IOBli
09/03/02 ISSUEO FOIl F1UNG
o 08/16/02 ISSUEO FQR PllEUIolINARY REVIEW
L.T. N.M
S.M N.M.
S.M. N.M
ORW CHK
8Y 8Y
D^'"
NO. DATE
DESCRIPTION
APPROVALS
SIGNATURE
V~CESmEAl.4
ONR/l"~ORD
LEASING/SAC
RF ENGINEER
ZONING
CONSmUCTlON
'"
w
'"
5
a
w
'"
~
"
WILLIAM F. COLLINS. AlA
ARC HIT B C T S. LLP
>>-1 'IBCHNOI..OGY DRIVB SETA.TJmr, NY om
VOICE . C5Jl-QlSI--84SO FAX I 631~
....://.........fc.t..c..
PROJECT # 02-4900
~Omnipoint
~ COMMUNICATIONS INC.
asanogenllor
llmn~IFociiliesNeltork2.LLC.
-4 Sylvan Way. Parslppany, NJ 07054
Omnipaint Communications Inc. is a subsidiary
of VoiceStream Wireless Corporation
SITE INFORMATION
CUTCHOGUE
71855 COUNTY ROAD 48
CUTCHOGUE, N.Y. 11935
LI-13-544-A
DESIGN TYPE
NEW BUilD
COlOCA TION MONOPOLE
SHEET TITLE
ENLARGED PART. SITE PLAN
& DETAilS
SHEET NUMBER REV.
A-3 2
,
n
I
;"
;"
I
in
m
I
;"
NORTEL $12000 EQU!PMENT
CABINET SUPPLIED BY CARRIER,
INSTALLED By CONTRACTOR.
N
I
N
L~'
NOTE:
(3) CABINETS TO BE NORTEL 512000 EQUIPMENT CABINET
SUPPLIED BY OMNIPOINT, AND INSTALLED BY CONTRACTOR.
REFER TO CABINET MANUFACTURER SPECIFICATIONS AND
DRAWINGS FOR MORE INFORMATION.
SPECIFICATIONS:
75" TALL x 53" WIDE x 26" DEEP
CELL CAPACITY: 12 TRX CALLS PER UNIT
WEIGHT: 1212 LBS
ELECTRIC REQUIRED: 230V TO 240V
o
I
in
PLAN" EQUIPMENT CAB,
4'-5"
o
ATTACH CABINET TO 18
GAUGE SHEET METAL
SUB-BASE SUPPLIED BY
THE CONTRACTOR WITH 1/2"
HIGH STRENGTH BOL 15.
NEW CONCRETE SLAB.
.
4
SECURE NEW OMNIPOINT EQUIPMENT
CABINET SUBASE TO NEW CONCRETE SLAB
WITH 1/2" 5/5 RODS SET IN HllTI HIT
HY-150 CHEMICAL ANCHORS. MINIMUM
3-1/2" EMBEDMENT. (TYP)
TYPICAL EQUIPMENT CABINET DETAILS
SCALE, 1/2" - " 0"
n
I
;"
.
~
.'
.
ANTENNA INFORMATION
ANTENNA TYPE: EMS WIRELESS
MODEL No. RR65~19~02-0P
W1RElF"SS PI ATFORM NOTE:
CONTRACTOR SHALL INSTALL (3) WIRELESS SECTOR CROSS
ARMS ATTACHED TO UNINVERSAL TRI-BRACKET FOR POLYGON
AND ROUND POLE STRUCTURES MANUFACTURED BY VALMONT
M1CROFLECT PRODUCT No. .. AS SPECIFIED BELOW, PER
DIAMETER OF MONOPOLE POLE. (V.I.F.)
TRI RRACKET PRODUCT No. FOR POLE
1 O~ - 2' 1 ~
"_10" - .)'_2N
3'_ON - 4'-2"
4'_QN - 5'-0"
SEr.TOR CROSs ARM
FOR (4) ANTENNAS, 13' FACE
NEW OMNIPOINT PANEL
ANTENNAS. (TYP FOR 12)
SECTOR 'c'
270.
2 J/B"1lI MICRQFLECT ANTENNA
MOUNTING PIPE TYP. OF (12),
LENGTH AS REQUIRED.
MICROFlECT TRI INTERFACE
BRACKET AS REQUIRED FOR
DIAMETER OF MONOPOLE
AT RESPECTIVE HEIGHT.
DIA.
82592
82593
82594
82606
t!Qli;
STRUCTURAL ENGINEERING FOR
ANTENNA MOUNTS BY OTHERS.
, 01/\7/0J RfV.PfRTOWN.lT-IKIIllLE LT. N.l..1.
, 09/03/02 ISSUED ~OR flUNG S.l..1. N..
, 08/16/02 ISSUED ~OR PRfLIUlNAAY REVIEW S.l..1. N..
NO. ''"' OESCRIPT10N "" CH'
Y BY
APPROVALS SIGNATURE DATE
VOICfSTREAt.4
OMIDl/L.t.NOLCIlD
LEASING/SAC
Rf ENGINEER
ZONING
CONSTRUCTION
f['"
8'
!~
13' FACE, SECTOR CROSS
ARM FOR (4) WIRELESS
ANTENNAS.
B1822
EXISTING MONOPOLE
FOUNDATION
WILLIAM F. COLLINS, AlA
ARC HIT E C T S. LLP
EXISTING MONOPOLE
10-1 "IECIn<<:lLOGY DRlYB Sln'AUKEI". NY 1I7.D
VOICB ' l53l-6lI9-845O FAX , ~
.tt,:llwww.wfcata.c..
\'"
0...-
-:"0
0,'1'
.$>_
o ~~~~~, ~~UNTlNG DETAIL
I~
.llilIL
EMS ANTENNA
TYPE RR65-19-02
DUAL POL
PROJECT # 02-4900
~~M~~C~~~~~ct
os an agenllor
CIJm4loinlrociiliesNtlwirl2,LLC.
.( Sylvan Way, Parsippany, NJ 07054
RF CONNECTORS
SHEET NUMBER
REV,
MOUNTING BRACKETS (TYP)
Omnipalnl Communications Inc. is a subsidiary
of VolceSlream Wireless Corporation
CD
ANTENNA DETAIL
SCALE,1/2"-"-0"
SITE INFORMATION
(0 '0
I I
;.., io
CUTCHOGUE
71855 COUNTY ROAD 48
CUTCHOGUE, N. Y. 11935
L1-13-544-A
DESIGN TYPE
NEW BUILD
COLOCA TION MONOPOLE
SHEET TITLE
TYP, EQUIP, CABINET &
ANTENNA PLATFORM DETAILS
~t=a
N W
TOP WEN
A-4
2
AlOIIT WEN
BIlE WEN
BACK
o
MICROFLECT 83013 PIPE CAP FOR 3 1/2"
0.0. PIPE.
MICROFLECT 8301 24" BRIDGE SUPPORT
ARM BRACKET.
MICROFlECT 82734 GRATING TYPE 24"XlO'
BRIDGE CHANNEL SECURE TO SUPPORT ARM
WITH MANUF. RECOMMENDED HARDWARE.
MICROFLECT 81890 TRIPLE TRAPEZE SUPPORT
KIT PROVIDES SUPPORT FOR (24) 7/8"0
COAX CABLES SECURED BY 81560 $NAP-I
HANGERS.
MICROFLECT 8130 .3 '/2~ GALV STEEL
SCHEDULE 40 PIPE MOUNT SET IN CONCRETE
BASE AS INDICATED. SEE MANUFACTURERS
SPECIFICATIONS FOR RECO~MENDED SPACING.
WATERPROOF SEALANT
3/4" CHAMFER
CONTRACTOR SHALL TRIM SONOTUBE DOWN
TO GRADE AFTER CONCRETE HAS CURED.
PAINT PORTIONS OF POST TO BE EMBEDDED
IN CONCRETE WITH CUT -BACK ASPHALT
PAINT, TYPICAL.
POURED CONCRETE FOOTING, SET PIPE
MOUNT AS INDICATED WITHIN. CONTRACTOR TO
'DE -WATER' TRENCH AS REQUIRED DURING
INSTALLATION OF CONCRETE TO ENSURE
PROPER INSTALLATION STRENGTH. CONCRETE
TO ACHIEVE A COMPRESSIVE STRENGTH OF
4,000 PSI @ 28 DAYS, AIR ENTRAINED
UNDISTURBED EARTH.
12" III SONOTUBE FORMED CONCRETE BASE
=
PROVIDE (1) CABLE SUPPORT POST.
ELEVATED CABLE SUPPORT DETAIL
SCALE, 1/2" - 1'-0"
ANTENNA CABLES (SIZE AS LENGTH
REQUIRES.)
~SELF DRILLING/TAPPING SCREWS
24 N D.C. TO SECURE COVER.
:; ALUMINUM LADDER TYPE CABLE TRAY, SIZE AS
SPECIFIED. PART NUMBER
37-A-12-12(*)-120(**) MANUFACTURED BY
'B-lINE' WI SOLID FLANGED NON-VENTILATED
LOCKABLE COVER. PROVIDE ALL NECESSARY
HARDWARE. STRAIGHT SECTIONS AND BENDS AS
INDICATED. SECURE CABLE TRAY TO SLEEPERS
WITH APPROPRIATE HARDWARE.
* WIDTH AS REQUIRED
** SECTION LENGTHS AS REQUIRED
SECURE TO CONCRETE PAD
WITH SIS FASTENERS.
4N X 4" PRESSURE TREATED WOOD
SLEEPERS. (2) PER TRAY SECTION.
ANTENNA CABLE TRAY DETAIL
SCALE, AS NOTED
.'
.
CONCRETE EQUIPMENT PAD
lYP, SECTION lHAU CABLE TRAY
SCALE: 1" = 1'-0"
~
SOLID FLANGED ALUMINUM
NON-VENTILATED CABLE TRAY
COVER BY B-lINE (TYP)
STENCIL NOTE ON TOP OF CABLE
TRAY @ EVERY 6 FEET
DETAL -lYP. CABLE TRAY COVER
SCALE: N.T.S.
NEW 5' TALL AMERICAN
ARBORVITAE EVERGREEN TREES
TO BE PLUMB AS SHOWN ON
l/A-.3. (GUARANTEE TREES FOR
A PERIOD OF ONE YEAR)
CEDAR BARK CHIPS
'/2"0 RUBBER HOSE AND 12 GA.
GALV. WIRE PROVIDE
TURNBUCKLES [3J OR TWIST
ADJUSTMENT.
NOTE:
BARE ROOT PLANTS Will NOT
BE PERMITTED. ALL PLANTING TO
BE PRUNED IN ACCORDANCE
WITH BEST & ACCEPTED
NUSERYMAN'S PRACTICE
"
SUBSOIL I
BACKFIll WITH TOPSOIL MIXED~I
WITH 0/20/0 FERTILIZER AT THE -
RATE OF (5) POUNDS PER
YARD. WATER THOROUGHLY AND
Fill TO EXISTING EARTH LINE
ON TREE TRUNK.
[3J CEDAR STAKES DRIVEN AND
DRAWN STRAIGHT. STAKES SET
AT 120' INTERVALS AND
EQUAL-DISTANT FROM TREE
CD ~~~~~~~E PLANTING DETAIL
OI/17/03RE.V.PE:R~"'T-MOBlE
09/0J/02ISSuroFORFlUNG
o OB/16/02ISSUEDfORPREUldIW.RYRE.VIEW
NO_ DATE DESCRIPTION
LT. N.t,I
S.t,I. N.t,!.
S.M. N.t,I.
R CHK
BY BY
DATI:
APPROVALS SIGNATURE
VOICESTREAM
O'/INffi.A-AtlIlORO
LEASING/SAC
RfENGlNEER
ZONING
CONSTRUCTION
WILLIAM F. COLLINS. AlA
ARC HIT E C T S. LLP
- ---
IH 'J'BCHNOLOGY" DRIVB IBTAlJDT, NY IJ73J
VOICE . l53l--fii89--l45O PAX . 6:Jl~
'- t t ,:/ /w.,. ..'e ala. c..
-------..
PROJECT # 02-4900
~Omnipoint
~ COMMUNICATIONS INC.
as on oqert lor
~rocitiesNelm12,lLC.
~ Sylvan Way, Parsippany, NJ 0705-4
Omnipoint Communications Inc. is 0 subsidiary
of VoiceSlream Wireless Corporation
SITE INFORMATION
CUTCHOGUE
71855 COUNTY ROAD 48
CUTCHOGUE, N.Y. 11935
L1-13-544-A
DESIGN TYPE
NEW BUILD
COLOCA TION MONOPOLE
SHEET TITLE
DETAILS
SHEET NUMBER
REV.
A-S
2
ANTENNA SCHEDULE CABLE SCHEDULE
SECTOR MDT RX- TX MANUF - MODEL# CABLE LENGTH DIA. LABEL
TX TX 140' 1-1/4" 1 RED
A 3D. O. EM$-RR-65-19-02
RX RX 140' 1-1/4" 2 RED
TX TX 140' 1-1/4" 3 RED
A 3D. O. EMS-RR-65-19-02
RX RX 140' 1-1/4" 4 RED
TX TX 140' 1_1/4ff 5 RED
A 3D. O. EMS-RR-65-19-02
RX RX 140' 1-1/4" 6 RED
TX TX 140' 1-1/4" 7 RED
A 3D. O. EMS-RR-65-19-02
RX RX 140' 1-1/4" 8 RED
TX TX 140' 1-1/4" 1 WHITE
8 150' O. EM$-RR-65-19-02
RX RX 140' , -1/4" 2 WHITE
TX TX 140' 1-1/4" 3 WHITE
8 150' O. EMS-RR-65-19-02
RX RX 140' 1-1/4" 4 WHITE
TX TX 140' 1-1/4" 5 WHITE
8 150' O. EM$-RR-65-19-02
RX RX 140' 1-1/4" 6 WHITE
TX TX 140' 1-1/4" 7 WHITE
8 150' O. EMS-RR-65-19-02
RX RX 140' 1-1/4" 8 WHITE
C 270" O. TX TX 140' 1-1/4" 1 BLUE
EMS-RR-65-19-02
RX RX 140' 1-1/4" 2 BLUE
TX TX 140' 1-1/4" 3 BLUE
C 270' O. EM$-RR-65-19-02
RX RX 140' 1-1/4" 4 BLUE
TX TX 140' 1-1/4" 5 BLUE
C 270' O. EM$-RR-65-19-02
RX RX 140' 1-1/4" 6 BLUE
TX TX 140' 1-1/4" 7 BLUE
C 270. O. EM$-RR-65-19-02
RX RX 140' 1-1/4" 8 BLUE
8 ANTENNA SCHEDULE
BILL OF MATERIALS
NO. QTY.
3
2 48
3 48
4 24
5 24
6 48
7 12
8 12
9 6
10 6
11
12
13
14
15
16
17
18
PART H
DESCRIPTION
NORTEL 512000 BTS
7/8" GROUND KITS
WEATHERPROOFING KITS
MANUFACTURER
NORTEL
CABLEWAVE
CABLEWAVE
DIN(M)~DIN(M) 1/2N - 6-0" SUPERFLEX JUMPERS CABLEWAVE
DIN(M)-DIN(M) 1/2" 6' -0" JUMPERS CABLEWAVE
7/B" DIN(F) CONNECTORS CABLEWAVE
DUAL POL ANTENNA MODEL # RR65-19-02 EMS WIRELESS
MECH. DOWNTILT BRACKETS
LOW NOISE AMPLIFIERS (LNA)
OIN(M)-DIN(M) 1/2" - 3'-0" JUMPERS
EMS WIRELESS
CABLEWAVE
o BILL OF MATERIALS
LEGEND
NEW
EXISTING
FUTURE
r-..,
L_...J
I;;:~~
'."''2,6:''- V~.;
.fE.....
CJ
TYP. SECTOR CABLE ROVTlNG
DUAL Pal ANTENNA
(TYP 4 PER SECTOR)
3' -a" STD JUMPERS
6' -o~ STo JUMPERS
COAXIAL CABLES
NORTEL
S 12000 BTS
(lYP OF 3)
6' -0" SUPERFl FX
JUMPERS
GENERAL NOTES
1. ALL INDICATIONS OF NORTH ARE FOR
REFERENCE ONLY. CONTRACTOR TO VERIFY IN
FIELD TRUE NORTH PRIOR TO SECTOR
ANTENNA INSTALLATION.
2. ALL ANTENNAS TO BE MOUNTED ON OOWNTILT
BRACKETS.
3. CABLE LENGTHS LISTED ARE APPROXIMATIONS
BASED ON THESE PLANS AND ARE NOT
INTENDED TO BE USED FOR ORDERING CABLE.
ALL CABLE LENGTHS MUST BE V.J.F.
4. THE CONTRACTOR SHALL INSTALL BRASS TAGS
(SUPPLIED BY OMNIPOINT) AT EACH END OF
ALL ANTENNA CABLES DENOTING THE NUMBER
OF TAPE MARKING BANDS AND COLOR OF
TAPE MARKING BANDS.
5. ANTENNA CABLES WILL BE COLOR CODED AT
THE ANTENNA, FILTER INJECTION CABINET,
JUMPER CONNECTIONS AND THE BTS CABINET.
6. THE CONTRACTOR SHALL INSTALL DRIP LOOPS
ON ALL ANTENNA AND JUMPER CABLES.
7. THE CONTRACTOR SHALL INSTAll ADDITIONAL
CABLE SUPPORTS AS NEEDED TO MAINTAIN A
MINIMUM SPACING OF 3' _ON ON CENTER.
MIN. CABLE BENDING RADIUS
CABLE RAllIJS
1/2~ CABLE SUPERFLEX 1 1/4N
(FSJ-4-508)
1/2" CABLE (LOF-4-508) 5"
7/B" CABLE (LDF-5-50A) 10"
1/4" CABLE (LDF-6-50) 15~
1 5/B" CABLE (LOF-7-50A) 20N
CABLE SIZES/LENGTHS
UNLESS OTHERWISE NOTED:
fOR SECTORS 0'-100' USE 7/8" fJ CABLE
FOR SECTORS 101'-150' USE 1-1/4" ~ CABLE
FOR SECTORS 151'& ABOVE USE 1-5/B~ ~ CABLE
SECTOR 'A'
SECTOR 'B'
SECTOR 'c'
_ /!'-::" JUMPER (TYP)
S ~ ~ ~
z z z
6 is is
DUAL POL
ID-'-G ~_I
0--0
_ - fJ 1;;''' SUPERFLEX JUMPER (TYP)
~~ ~ ~
z z z z
[) is [) is
1 1/4 N0 CABLE (TYP FOR
l3--'--O ~ ~, ,- "~ .-~
SECTOR "A~)
"~'--''21
z
"
0--0 I~~
",,;'"'"":s.~,1
" '-'''~,I 0--0
CD ANTENNA CABLE ROUTING SCHEMATIC
0--0 k='~~~"
-~'-, " '" iiii!,1 0--0
0--0 I-~'-=
0--0 1"_ .__.~--~-~=.=. '~-~-,-- ,-~~ 0--0
0--0 1- -~--=,--=,,~,-"-~----'-=--'lIlB1 0--0
0--0 I-~-~----'~~-' --_.' ,'--"---="lIlB1
0--0 1Ai!'.zr: ':z;;"r~ ~",,,,,,.,
""~~$.._._.~~="..=-.I.-
DUAL POL
~._".....--......._-.
" j'if"""~ -<:'>'" ~ _.
""-.. ."-
DUAL POL
~-
[}----{J .. . D~A~.. POL
~:ilB~~1
",.'.'.~,..,",",..=_~'-V
[}----{J .. .1G0"~'*'~"~,~,~
0--01
1 1/4 "0 CABLE (TYP FOR SECTOR "B")
._-~._~ """"""'" [}----{J
"'-"'~'BI'iI!lII [}----{J
[}----{J 1-- ~
0--0'
IiI---iiI 1
IiI---iiI ,
IlI---iliI
IiI---iiI 1
IlI---iliII
1 1/4"fJ CABLE (TYP FOR SECTOR "C")
1iI---iiI1:IR
0--0 1-
._"'-.
.~-
--
...
0--0
,
IiI---iiI
IiI---iiI
iii
IlI---iliI
IiI---iiI
DUAL POL
-
DUAL POL
-
DUAL POL
iii
"'----'"' DUAL POL
...---u ~_
0--0
1iI---iiI1~-.''''
1iI---iiI1:m'"..'...."....-. ".....;~.=--""""~:z;...=."._~~~~~="'.,-=x~,."'"'_ [}----{J
~ "_..~._-_. 0--0
O--Ol:ll!il'
~="""',,""~"'-"""'''''''--~
- iiRI [}----{J
-~I e----o
1iI---iiI1_ _ m----m
_ e----o
0--0 1_ _.~_.~~~_.....
1iI---iiI1-~~
DUAL POL
~-
DUAL POL
~-
",',,' . ........ .--
DUAL POL
"1nW~.t 'yT
f;]~~
, 01/17/03 REV. Pf:RTOWN&cT-IM:lBILE LT. N.M.
1 09/03/02 ISSUEOF~F1l1NG S.M. N.M.
0 llfI/16/llZ IssumFORPRHIUINAAYR(V(W s.. N.M.
'0 DATE DESCRIPTION ~~wt. C",
"
APPROVALS SIGNATURE om
VOlCESTREAM
OWNffi,AAtO.llm
LEASING/SAC
RF ENGINEER
ZONING
CONSTRUCTION
WILLIAM F. COLLINS. AlA
ARC HIT B C T S. LLP
JD-t TBCHNOLOGY DRIVB SBTAUKIIT, NY IIlD
VOICE ' 631-Q19-84SO PAX . 631~
....:II...........fc.t..e..
/;2
PROJECT # 02-4900
~~M~~C~~~~~ct
as lIlogelt 101
~lrdtiesNehll:wt2,LLC.
4 Sylvan Way, Parsippany, NJ 07054
Omnlpolnt Communicafions Inc. Is a subsidiary
of VolceStream Wireless Corporation
SITE INFORMATION
CUTCHOGUE
71855 COUNTY ROAD 48
CUTCHOGUE. N,Y, 11935
L1-13-544-A
DESIGN TYPE
NEW BUILD
COLOCA TION MONOPOLE
SHEET TITLE
ANTENNA SCHEDULE. B.O.M..
& ROUTING SCHEMATIC
SHEET NUMBER REV.
A-6
2
ABBREVlA TlONS AND LABELS
1 fIFl.TRK'> NEW 200AMP SERVICE WITH 20aV OR 24QV, 2P, 3 WIRE FEEDER FROM A RELIABLE SOURCE TO THE COMMUNICATION AFF ABOVE FINISHED FLOOR
CABINET. THIS SOURCE SHALL BE LOCKED ON WITH A C8 LOCK. THE CONTRACTOR SHALL PROVIDE 20 SPARE FUSES WHEREVER A
FUSED DISCONNECT IS REQUIRED. THE CONTRACTOR SHALL VERIFY (BEFORE ANY CONSTRUCTION 1$ STARTED) THAT THE POWER AFG ABOVE FINISHED GRADE
SOURCE IS BETWEEN 20BV AND 240V LINE TO LINE. IF IT IS NOT BETWEEN THE SPECIFIED VOLTAGE. THEN CALL THE ARCHITECT. (ALL AWG WIRE GAUGE
ELECTRICAL EQUIPMENT SHALL BE LABELED WITH BLACK PLASTIC TAGS BEARING 'YSTR" WHITE LEDER ENGRAVING.) AMERICAN
C CONDUIT
? UTiliTY METFR: IF A UTILITY METER IS SPECIFIED ON THE DRAWINGS, IT IS THE CONTRACTORS RESPONSIBILITY TO OBTAIN ALL CB CIRCUIT BREAKER
NECESSARY INSPECTIONS, CUT -IN CARDS, ETC., THAT ARE REQUIRED TO SET THE METER. THE CONTRACTOR SHALL MEET WITH THE EMT ELECTRICAL METALLIC TUBING
UTILITY COMPANY TO VERIFY METER AND TAP LOCATION PRIOR TO INSTALLATION. THE ARCHITECT BEGINS THE PAPERWORK WITH THE
VARIOUS UTILITY COMPANIES AND CAN PROVIDE THE ELECTRICAL DESIGNER'S NAME AND PHONE NUMBER. CONTACT THE ARCHITECT GND GROUND LINE TYPES
FOR UTILITY RELATED QUESTIONS. IF TEMPORARY POWER IS REQUIRED, ALL NEC AND/OR LOCAL ELECTRIC CODES SHALL BE ADHERED
TO. CONTACT VOICESTREAM PRIOR TO MAKING TEMPORARY POWER CONNECTIONS. MC METAL CLAD CABLE
Mea MAIN CIRCUIT BREAKER E EXISTING ELECTRIC
NE- NEW ELECTRIC
, TFI fPHONF' NEW TELEPHONE SERVICES IN NY, NJ & CT, SHALL INCORPORATE A NEW 4" CONDUIT WITH A DRAGLlNE FROM THE MOP MAIN DISTRIBUTION PANEL
SPECIFIED UTILITY POLE TO THE LOCATION OF THE NEW DEMARCATION POINT. IN NY, NJ & CT, A NEW 2" CONDUIT (WITH (2) #8768 T EXISTING TELEPHONE
MGB MASTER GROUND BAR
BELDEN CABLES) IS REQUIRED FROM THE COMMUNICATIONS CABINET TO THE MAIN DEMARCATION POINT. IN MULTIPLE STORY NT - NEW TELEPHONE
BUILDINGS, WITH THE APPROVAL OF THE LOCAL TELEPHONE COMPANY, !N ORDER TO MINIf.-lIZE COST, NOISE GENERATION, AND MLO MAIN LUGS ONLY
DISRUPTION TO EXISTING BUILDING FUNCTIONS, AN ALTERNATE DEf.-lARCATION POINT CLOSER TO THE CELLULAR EQUIPf.-lENT f.-lAY BE - - - - NE - - - NEW UNDERGROUND ELECTRIC
SPECIFIED. N NEUTRAL EXISTING UNDERGROUND ELECTRIC
---- E ~--~
NEC NATIONAL ELECTRIC CODE ---- NT --- NEW UNDERGROUND TELEPHONE
4 ('()!...IIlIIlT J;'()llTlt..ll> THE ROUTING OF THE CONDUIT SHALL BE SUCH THAT THE EASIEST AND MOST PRACTICAL f.-lETHODS ARE OFN OMNIPOINT FACILITIES NETWORK ----T---~ EXISTING UNDERGROUND TELEPHONE
EMPLOYED WITH MINIMAL IMPACT UPON THE ONGOING SITE ACTIVITIES AND THE AESTHETIC APPEAL OF THE SAID SITE. THE WORK
BEING DONE MAY BE WITHIN EXISTING STRUCTURES. DRAWINGS ARE DIAGRAMATIC AND IT IS NOT THE INTENT TO SHOW EVERY JUNCTION PNL PANEL ~-~~ PROPERTY LINE
BOX, LB, CONDUIT BEND, ETC. BUT RATHER TO INDICATE COMPLETE SYSTEMS AND THE DESIGN INTENT. IT IS FOR THIS REASON THAT
THE CONTRACTOR MUST V!SIT THE SITE BEFORE SUBMITTING THE BID AND UNDERSTAND THE TRUE NATURE OF THE REQUIREMENTS AT PP POWER PANEL
THAT SITE. CONTRACTOR SHALL PROVIDE ALL COMPONENTS AND APPURTENANCES NECESSARY, WHETHER SHOWN ON THE DRAWINGS OR pve POLW1NYL CHLORIDE
NOT, FOR A COf.-lPLETE AND FUNCTIONING SYSTEM AND INCORPORATE ALL COSTS FOR THE SAME IN THE BASE BID.
RA RIGID ALUMINUM
, JCnlllPunn. ALL PANELS, DISCONNECTS, AND EQUIPMENT SHALL BE SQUARE 0 UNLESS DIRECTED OTHERWISE BY THE ARCHITECT OR RGS RIGID GALVANIZED STEEL
VOICESTREAM PROJECT MANAGER.
WP WEATHERPROOF
(2) DESIGN CRITERIA 0 ABBREVIATIONS
1 C;FNFRAI' ALL WIRING IN FINISHED AREAS SHALL BE CONCEALED UNLESS NOTED OTHERWISE. IN UNFINISHED AREAS SUCH AS
BASEMENTS, MECHANICAL ROOMS, ELECTRICAL CLOSETS, ETC. WIRING SHALL BE ROUTED ON THE INTERIOR SURFACE. NO WIRING
SHALL BE ROUTED ON THE OUTSIDE SURFACES OF THE BUILDING UNLESS SPECIF!CALL Y NOTED. ALL NEC AND LOCAL ELECTRIC CODES
SHALL BE ADHERED TO. ALL CONDUCTORS SHALL BE COPPER UNLESS OTHERWISE NOTED. ~ DFSCRIPTION ~ DESCRIPTION
? AFIOW GRAnf (UNDERGROUND IN FARTH OR FILL): ALL CONDUITS SHALL HAVE A MINIMUM BURIAL DEPTH OF 24". BRANCH = DISCONNECT SWITCH d:b RECEPTACLE
CIRCUITS SHALL CONSIST OF PULLED CONDUCTORS IN DIRECT BURIED SCHEDULE 40 PVC CON DUns. WHERE HEAVY VEHICLE TRAFFIC
OVER CONDUIT RUNS IS ANTICiPATED THE CONDUIT SHALL BE ENCASED IN CONCRETE. CONCRETE ENCASEMENT SHALL BE 3" MINIMUM
ALL AROUND AND BETWEEN CONDUITS. ALL ELBOWS USED WITH PVC CONDUIT SHALL BE SCHEDULE 80 PVC. ALL CONDUIT INSTALLED 5' ELECTRIC METER . NEW UTILITY POLE
ABOVE FINISHED GRADE SHALL BE SCHEDULE 80 PVC UNLESS OTHERWISE INDICATED BY PREVAILING CODE. PRIOR TO EXCAVATION, A
UTILITY 'MARK-OUT' SHALL BE DONE TO LOCATE EXISTING UNDERGROUND UTILITIES. PHOTOGRAPHS FOR ALL PUNCHLlST PURPOSES
SHALL BE TAKEN OF ALL UNDERGROUND WORK PRIOR TO BACKFILLING. 0 EXISTING UTILITY POLE
-=- PANEL BOARD
INnOOR (UNCI ASSIFIFn ARFAS)' ALL FEEDERS SHALL CONSIST OF PULLED CONDUCTORS IN EMT. ALL BRANCH CIRCUITS SHALL - MASTER GROUND BAR
, cr---. (TURNING UP)
CONSIST OF PULLED CONDUCTORS IN EMT. 15 AND 20 AMPERE 1 POLE LIGHTING CIRCUITS, OR MISCELLANEDUS BRANCH CIRCUITS ELECTRICAL WIRING
CONCEALED ABOVE SUSPENDED CEILINGS OR WITHIN DRYWALL PARTlTIONS SHALL CONSIST OF TYPE MC METAL CLAD CABLE IF
PERMITTED BY CODE. CONNECTIONS TO COMMUNICATION CABINETS AND VIBRATING EQUIPMENT SHALL CONSIST OF PULLED [=-:J INSULATED GROUND BAR
CONDUCTORS IN FLEXIBLE METALLIC CONDUIT, MAXIMUM 3' IN LENGTH. MINIMUM EMT SIZE TO BE 3/4". ~ ELECTRICAL WIRING (TURNING DOWN)
g -=- UNINSULATED GROUND BAR
4. OumOOR OR INDOOR (Cl ASS/FlED 'DAf.-lP' OR'WFT' lOCATION): ALL FEEDERS AND BRANCH CIRCUITS SHALL CONSIST OF PULLED COMMUNICATIONS CABINET
CONDUCTORS IN RGS CONDUIT. CONNECTIONS TO COMf.-lUNICATION CABINET AND VIBRATING EQUIPMENT SHALL CONSIST OF PULLED
CONDUCTORS IN LIQUID TIGHT fLEXIBLE STEEL CONDUIT, MAXIMUM 3' IN lENGTH. @ GROUND TEST WELL
= BACKBOARD
@ GROUND ROD
o WIRING CRITERIA o SYMBOLS
01/17/03 REV,PERTOI'l'NlT-t.IOBlU:
09/03/02lSSUEDfORFlUNG
o OB/15/02lSSlJEOfORf'R[UldINI.R'fREVlEW
NO. DATE DESCRIPTION
LT. N.I,1.
$.1,1.".1,1.
5.1,1. N.l.1.
R CHI<
, "
DATE
APPROVALS
SIGNATURE
VOlCE5TREAI,1
O'II'h{R/lANDl.ORO
LEASING/SAC
RrEN(]NEER
ZONING
CONSTRUCTION
WILLIAM F, COLLINS, AlA
ARC HIT E C T S, LLP
11)-1 TBCHNOLOOY DRIVE SBrAllXET, NY am
VOICE ' 631~ FAX ' 631~
II..,: / / w w w... feat. .c..
"",":"",:,~,
A,<'\:BC,"-.~
......~:..~..R'.:>..
/.. ,. "15. or'...
. \^ '~.
/2 '.... '..C
IA . '. I
Vfl~ . I.
. I VI 1.#"'4.".,; I -
PROJECT # 02 4900
~Omnipoint
~ COMMUNICATIONS INC.
os on ogent lor
Omn~nt rociiies~lrcrl2, l.LC.
4 Sylvan Way, Parsippany, NJ 07054
Omnlpoint Communications Inc. is a subsIdiary
af VoiceStream Wireless Corporation
SITE INFORMATION
CUTCHOGUE
71855 COUNTY ROAD 48
CUTCHOGUE. N.Y. 11935
1I-13-544-A
DESIGN TYPE
NEW BUILD
COLOCA TION MONOPOLE
SHEET TITLE
GENERAL ELECTRIC
NOTES AND SYMBOLS
SHEET NUMBER
REV.
E-1
2
EXISTING MONOPOLE BY OTHERS,
EXISTING CHAN LINK
FENCE TO REMAIN.
(J) NEW OMNIPOINT
EQUIPMENT CABINETS
MOUNTD ON NEW 10'X20'
POURED CONCRETE SLAB,
NEW CHAIN LINK
FENCE ON TOP OF
NEW CONCRETE
PAD.
(10) NEW J'I!lKS'
HIGH ARBOVITIES
EVERY 4' O.C.
......
NEW TRENCHED TELCO AND
ELECTRICAL CONDUITS ROUTED TO
NEW OMNIPOINT EQUIPMENT. (SEE
DETAIL 2/A-2.)
EXISTING TRANSFORMER ATOP
CONCRETE PAD.
EXISTING UTILITY POLE.
=
ALL TRENCHING OF CONDUITS
TO BE DONE BEFORE NEW
ARBOR VI TIES ARE PLANTED.
t:!QIE:
REFER TO DETAIL 2/A-2 FOR
ELECTRIC AND TELCO CONDUIT
TRENCHING.
=
THE CONTRACTOR SHALL CALL THE RESPONSIBLE UTiliTY
COMPANY PRIOR TO THE START OF CONSTRUCTION AND,
SCHEDULE AND PERFORM THE WORK UNDER THIS CONTRACT AS
TO MINIMIZE DISTURBANCES TO THE BUILDING TENANTS. ANY
SERVICE INTERRUPTIONS SUCH AS ELECTRICAL, TELEPHONE, GAS,
HVAC, WATER OR ANY OTHER UTILITY OR, EXCESSIVE NOISE
DISTURBANCES SUCH AS CORE DRILliNG SHALL BE
COORDINATED WITH THE BUILDING'S MANAGEMENT.
~
SERVICE PLAN
SCALE: 1 "~50' -0"
<3>
2" C WITH.3 # 4/0 XlP USE &; 1 # 6 CU
8
NEW
PANEL
P1
NOTE El0
NOTE
E8
wp _~~T1E
NOTE
E1
EXISTING
PAD
MOUNTED
TRANSFORMER
NOTE
E3
NOTE
E4
A
I
NOTE
E2
I
NOTE
E5
E2.
COORDINATE All NEW SERVICE REQUIREMENTS WITH L1PA
PRIOR TO BEGINNING NEW WORK.
PER lIPA, EXISTING SINGLE PHASE PAD MOUNTED TRANSFORMER
HAS ADEQUATE POWER FOR NEW SERVICE. PROVIDE NEW E8
SECONDARY TAP FROM TRANSFORMER FOR NEW OMNIP01NT .
SERVICE. COORDINATE ANY OUTAGE WITH ALL lIPA CUSTOMERS
EMANATING FROM THAT TRANSFORMER IF NECESSARY.
PROVIDE AND INSTALL NEW NEMA JR, 200 AMP, 2 POLE FUSED
DISCONNECT SWITCH WITH SOLID NEUTRAL RATED FOR SERVICE
ENTRANCE EQUIPMENT. FUSE WITH BUSSMAN FRN 200 FUSES.
PROVIDE AND INSTALL #2 COPPER GROUND AND 3/4w X 10'
GROUND RODS FOR NEW SERVICE. MAXIMUM RESISTANCE TO
GROUND SHALL BE 5 OHMS. PROVIDE AND INSTALL ADDITIONAL
GROUND RODS NOT LESS THAN 6' APART TO MEET GROUND
RESISTANCE REQUIREMENTS.
PROVIDE AND INSTALL NEW PANEL Pl IN WEATHERPROOF
ENCLOSURE. PANEL SHALL HAVE ALL COPPER BUS, BOLT ON
BREAKERS AND DOOR IN DOOR HINGED CONSTRUCTION. PANEL
SHALL BE RATED 200A, 20B VOLT, 1 PHASE 3 WIRE WITH A
200A MAIN BREAKER. PROVIDE WITH THREE 50A-2P, AND lWO
20A-1P BREAKERS. AIC RATING TO BE 22KA.
El0. PROVIDE AND INSTALL NEW CIRCUITS TO EQUIPMENT
CABINETS PER OCS REQUIREMENTS.
&7.
ENGAGE THE SERVICES OF AN UNDERGROUND UTILITY LOCATING
COMPANY TO LOCATE ALL UNDERGROUND EQUIPMENT IN THE
AREA.
PROVIDE AND INSTALL NEW UNDERGROUND SERVICE TO METER
FROM TRANSFORMER. LENGTH Of RUN IS OVER 200'. PROVIDE
PULL BOXES AS NECESSARY. TRENCH, BACKFILL AND GRADE AS
REQUIRED.
PROVIDE AND INSTALL CONCRETE BASE WITH VERTICAL KINDORF
AS BRACING tOR NEW METER, PANEL AND TELCO EQUIPMENT.
AOD ADDITIONAL KINOORF FOR STRUCTURAL STABILITY.
PROVIDE AND INSTALL NEW 120/20B VOLT SINGLE PHASE 200
AMP OUTO OR METER.
E9.
Ell. PROVIDE AND INSTALL NEW LOCAL WEATHERPROOF Gfl
RECEPTACLE ON DEDICATED 20A, 1 POLE CIRCUIT.
ELEC RISER
SCALE: NO SCALE
IAGRAM
=
BTS "An
BTS "B"
BTS "C"
"
--;..- -"-
CD
7
KEY NOTES
CD NQRTEL SUB-BASE GROUND BAR
@ /12 AWG SQILD TINNED COPPER
GROUND WIRE TO NEW GROUND
RING
@ COAXIAL CABLE GROUNDING KIT.
TYP OF (24).
@ SECTOR GROUND BAR
rE\ CONDUIT FROM THE POWER
\!; SOURCE TO THE POWER PANEL
@ 200 AMP LOCKABLE ELECTRIC
POWER PANEL
(!) 2.5" RGS ELECTRICAL CONDUITS
@ CONDUIT FROM MAIN DEMARC
SOURCE TO DEMARC BOX
@ TELCO DEMARC BOX INSTALLED
BY CONTRACTOR SUPPLIED BY
OMNIPOINT
@2" RGS TELCO CONDUITS
WITH (2) BELDEN WIRES
@ COAXIAL ANTENNA CABLES.
TYPICAL OF (24).
@ 3n RGS CONDUIT FOR DAISY
CHAIN CABLES BETWEEN
CABINETS
BTS RISER DIAGRAM
SCALE: NO SCALE
03/OJ/03 REV. PE:R lIPA
2 01/n/OJ REV.PE:RTOWN&:Tt.IOBILE
1 09/OJ/02 ISSUED FOR FIl~G
o 08/16/02 ISSUED FOR PRElI~1tW!Y REVIEW
L.S. G.D.
LT. N.M.
S.lot. N.lot.
S.M. N.M.
DR CHK
BY BY
DATE
DATE
DE$CRIPT1QN
APPROVALS
SIGNATURE
WILLIAM F. COLLIN~ AlA
A R. CHI TEe T S. LLP
&i 'JBCHNOLOGY DIUVJ!. SErAUKET. NY m:u
VOICE . 631-Q&-l4SO PAX . 6Jl-6l&-l45!ll
."': II..... Ie at a.e._
----
PROJECT # 02-4900
~Omnipoint
~ COMMUNICATIONS INC.
osanoqenllor
Omnporrtfd\iesNellork2,lLC.
4 Sylvan Way, Parsippany, NJ 07054
Omnipaint Cammunicalians Inc. is 0 subsidiary
of VoiceStreom Wireless Corporation
SITE INFORMATION
CUTCHOGUE
71855 COUNTY ROAD 48
CUTCHOGUE. N. Y. 11935
LI-13-544-A
DESIGN TYPE
NEW BUILD
COLOCATION MONOPOLE
SHEET TITLE
ELEC SERVICE PLAN, RISER
AND BTS RISER DIAGRAMS
SHEET NUMBER REV.
E-2
2
1
;<
J
A TYP.
K
~M
@
~
L!\ ;\
l'i I~!" 1
./ L/ L-/
\
'-
I TYP.
/'
GROLJN[)ING I FGEND:
. GROUNDING SYSTEM CONNECTIONS
~ COPPER GROUND RODS
@) COPPER GROUND ROD IN TEST WELL
EQUIPMENT GROUNDING PLAN
SCALE: 1/8"~1'-0'"
INSPECTION HAND HOLE
ASSEMBLY
CAST IRON FLANGE AND
COVER WITH WORD 'GROUND'
CAST INTO COVER.
GRADE
41"1-1-"
i \
, -
I ,
I
I
I
I
I
I
I
I
.
:.
IIIWIIIII~
CABLE TO ROD CAD
WELDED
.'
4"
'-,
,-,~
.,.
..:
NOTL
INSPECTION HAND HOLE MAY
BE PRE CAST CONCRETE OR
pve AND SHALL BE A MINIMUM
OF 12~ I.D.X36" DEEP.
, .
o
I
;"
w
I
;"
;,
I
I
I
I
I
,
,
..
, .
.'
.
CLEAN SAND FILL
RING GROUND 112 AWG sew
'"
11_111-1_1_1--1
. .. ... ..\:'.. o.
.:::--~~. .....~.;~.."';..
:-r:-:-~::;"":~:~~~r:.
o
n ~ GROUND ROD COPPER WELD
~ 5/8" 0 x 10'-0" LONG
GROUND ROD TEST WELL DETAIL
SCALE: 1"~ l' -0"'
~
GROUNDING KEY NOTES
@ SECTOR GROUND BAR (SGB)
@ NORTEL SUB-BASE GROUND BAR (NGB)
@ AWG #2 SOLID TINNED COPPER WIRE FROM CABLE TRAY TO
EXTERIOR GROUND RING (EGR).
@ AWG 1/2 SOUD TINNED COPPER WIRE FROM SECTOR GROUND
BAR (SGB) TO EXTERIOR GROUND RING (EGR). TYPICAL FOR
ALl.
@ AWG #2 SOUD TINNED COPPER EXTERIOR GROUND RING (EGR)
BURIED 36" MIN. BELOW GRADE CONNECTED TO GROUND RODS
WHICH ARE INCORPORATED INTO EXTERIOR GROUND RING. ALL
CONNECTIONS ARE TO BE CAD WELDED AND SPRAYED WITH
COLD-GALVANIZED PAINT.
CD 5/8" X 10'_0" LONG COPPER CLAD STEEL VERTICAL GROUND
ROD IN INSPECTION TEST WELL BURIED 36" BELOW FIN GRADE.
(SEE DETAIL THIS SHEET)
@ 5/8" X 10'-0" LONG COPPER CLAD STEEL VERTICAL GROUND
ROD BURIED 36" BELOW FIN GRADE. RODS SHALL BE PLACED
NOT MORE THAN 15' & NOT LESS THAN 6' APART FROM
ADJACENT GROUND RODS. (SEE DETAIL THIS SHEET)
@ # 2 AWG SOUD TINNED COPPER WIRE FROM FENCE CORNER
POST TO EXTERIOR GROUND RING (EGR).
CD #6 AWG STRANDED COPPER WIRE CONNECTED FROM FENCE
SECTION TO SUPPORT POST AND TO EXISTING FENCE POSTS.
(CAD WELD)
Q) NEW GROUND BAR AT BASE OF MONOPOLE. ATTACH TO
EXISTING MONOPOLE GROUND RING w/ (2) 1/ 2 AWG BARE
COPPER WIRE.
@ 1/ 2 AWG SOUD TINNED COPPER OR NON-INSULATED COPPER
WIRE FROM MONOPOLE (EGR) TO EQUIPMENT CABINET (EGR.)
CD SERVICE ENTRANCE GROUND SHALL BE BONDED TO EXTERIOR
GROUND RING.
@ (8) , 6 AWG BARE COPPER WIRE FROM COAXIAL GROUND KITS
(CGK) TO SECTOR GROUND BAR (SGB). TYPICAL PER SECTOR.
@ #2 AWG SOUD TINNED COPPER WIRE FROM GPS CGK TO EGR.
PVC SLEEVE W/ 1/2 SOUD
TINNED GROUND WIRE TO
NORTEl GROUND BAR
'0'
~
4'-5"
11/16'" HOLE FOR
MOUNTING SUB~BASE TO
STEEL DUNNAGE OR
CONCRETE PAD. FOllOW
MANUFACTURERS SPEC
AND INSTAlLA~
PROCEDURES
o
,
m
I
;"
NORTEl S8000
EQUIPMENT CABINET ------
L.
NORTEL GROUND BAR --
PLAN
9"
~
8 3/4"
t-t
1~
J 3'-9" }
ElEVATION 'A' ~ CABLE ACCESS
BTS SUB-BASE DETAIL
SCALE: 1/2"~ 1'-0"'
PANELS
1000110001
000 000
GRADE
PROTECT THREADED
AREA FROM DAMAGE
DURING AND AFTER
INSTALLATION
CAD WEl
~,-,-
GROUND RING j
GROUND ROD
COPPER WELD ~" X
1 0' -0" LONG
GROUND ROD DETAIL
SCALE: 1/2"~ l' -0'"
2" RGS TELCO CONDUIT WITH
(1) 6 PAIR BELDEN CABLE
PER CABINET
1" PVC ELECTRICAL CONDUIT
W/ SEAlTIGHT CONDUIT TO
ELECTRICAL PANEL
SEAL TIGHT CONDUIT
ACCESS COVER
PLAN
CABLE ACCESS PANELS
J
~-
4'-5"
ElEVATION 'B'
z
"
01!17/0J REV. P{R TOW~ a: T-t.IOIlILI
09/0J/02 ISSL{D fOR RUNG
o 08/16/02 ISSUED fOR PREUMINAA'r' REVIEW
NO. DATE DESCRIPTION
LT. N.M.
S.M. NJ.4.
S.M. N.M.
R CHK
, "
DATE
'0
I
;"
APPROVALS
SIGNATURE
VOICESTREAM
OWNER/lANOlORO
LEASING/SAC
RFENGlNEER
ZONING
CONSTRUCTION
WILLIAM F. COLLINS, AlA
ARC HIT E C T S. LLP
JO-I "IB:HNOLOOY DIUYB SBTAVJCET. NY D7J3
VOICB'~ FAX'~
.tt,://www.wfca.a.c..
,.-~... ,-"--.~-~
~-~-;:,-~~~ .,,:
/.,p' , 7.;;;'<c
11"" "'~f ,.
I' , ',_ _!.. \
y,.~ ,:, , '~"~"""
':ld/.M. ~
\ tg,!
,-.,--"
~
PROJECT # 02 4900
~Omnipoint
~ COMMVNICA nONS INC.
lIStllagenlfor
~frociiiesNetwtri.2,LLC.
.( Sylvan Way, Parsippany, NJ 07054
Omnipoint Communlcafions Inc. is a subsidiary
of VoiceStream Wireless Corporotion
SITE INFORMATION
CUTCHOGUE
71855 COUNTY ROAD 48
CUTCHOGUE, N, Y. 11935
L1-13-544~A
DESIGN TYPE
NEW BUILD
COLOCA TION MONOPOLE
SHEET TITLE
EQUIPMENT GROUNDING
PLAN AND DETAILS
SHEET NUMBER REV,
E-3
2
GROUNDING GENERAL NOTES:
1. ALL GROUNDING SHALL COMPLY WITH THE MOST RECENT REQUIREMENTS OF NEC ARTICLES 250 AND 810 AND
OMNIPOINT STANDARD,
2. AlL DETAILS ARE SHOWN IN GENERAL TERMS, ACTUAL GROUNDING INSTALLATION AND CONSTRUCTION MAY VARY
DUE TO SITE SPECIFIC CONDITIONS.
3. IF USED, EXTERIOR GROUNDING RING SHALL BE BURIED TO MINIMUM DEPTH OF 3'-6" BELOW FINISH GRADE TO
TOP. ELECTRICAL METER GROUND EXCEPTED.
4. UNLESS OTHERWISE NOTED, GROUNDING CONDUCTORS SHALL BE:
A. BETWEEN EXTERIOR ITEMS AND BARS - #2 SOLID, TINNED, COPPER
B. EXTERIOR GROUND RING - #2 CONTINUOUS SOLID, TINNED, COPPER
C. BETWEEN GROUND KITS & BARS - #6 STRANDED GREEN THWN INSULATED COPPER GROUNDING CONDUCTORS
LARGER THAN #6 SHALL HAVE A MINIMUM BENDING RADIUS OF
12". GROUNDING CONDUCTORS #6 AND SMALLER SHALL HAVE A MINIMUM BENDING RADIUS OF 8".
5. GROUND SYSTEM SHALL BE TESTED IN ACCORDANCE WITH OMNIPOINT STANDARD PRACTICE AND SHALL HAVE A
RESISTANCE OF 10 OHMS OR LESS. SUBMIT AN INDEPENDENT FALL OF POTENTIAL TEST REPORT.
6. NOTIFY OMNIPOINT PROJECT MANAGER IF THERE ARE ANY DIFFICULTIES INSTALLING GROUNDING SYSTEM DUE TO
SITE SOIL/RESISTANCE CONDITIONS.
7. STANDARD GROUND RODS SHALL BE 5/8"0, 10' LONG, COPPER CLAD.
8. ALL CONNECTIONS EXTERIOR TO BTS EQUIPMENT CABINETS SHALL BE CADWElDED. All INTERIOR CONNECTIONS
SHAll BE EITHER CADWElDED OR HEXAGONAL COMPRESSION CRIMP, UNLESS NOTED OTHERWISE. ALL MECHANICAL
CONNECTIONS UTILIZING BOLTS SHALL BE MADE WITH TWO HOLE, lONG BARREL LUGS AND STAINLESS STEEL
HARDWARE. APPLY ANTI-OXIDANT AT ALL MECHANICAl CONNECTIONS.
9. THE FOLLOWING LIST OF ITEMS SHALL BE CONNECTED TO THE NEW MASTER GROUND BAR (WHERE APPLICABLE &
WITHOUT LIMITATION):
- ALL EQUIPMENT CABINETS
- EXTERIOR CABLE TRAY SYSTEM
- EQUIPMENT SUPPORT FRAME
- ANTENNA TRANSMISSION CABLES (2 LOCATIONS EACH)
- ANTENNA SUPPORTS
- ALL OTHER PERMANENT, SIGNIFICANT METALLIC OBJECTS WITHIN 6'-0" OF ANY OTHER GROUNDED OBJECT.
10. METALLIC CONDUIT SURROUNDING GROUNDING CONDUCTORS SHALL BE GROUNDED IN ACCORDANCE WITH NEC
ARTICLE 820-40(0)5. PROVIDE GROUND JUMPER FROM BONDING BUSHING TO NEAREST BAR USING #2 WIRE AND
OZ~GEDNEY TYPE HBLG BUSHINGS.
SEE NOTE 1
SECTOR A
SECTOR 8
SECTOR C
L"R
12.0G
sew (lYP.)
12 AWG BCW
(lYP.)
16.0G
sew (lYP.)
TOP or MONOPOlE
BOTIQtd OF 1.40NOPOLE
~
1. BOND ANTENNA GROUNDING KIT
CABLE TO GROUND BAR
2. RING GROUND FOR EQUIPMENT.
3. FOR GROUNDING CONNECTION &.
DETAILS, SEE LAYOUT DRAWINGS.
SECTOR A
SECTOR B SECTOR C
12.0G
BCW (TYP.)
16.0G
Beo (lYP.)
GPS
SECTOR C
SECTOR A
eGK
TYP (2)
SECTOR A
GROUND
RODS
(EXISTING)
12 AOG
BCW (TYP.)
NOTE 2 &: 3
GROUND
RODS
12 AOG
BCW (lYP.)
12 'WG BARE
COPPER WIRE
NOTE 2 &: 3
CONDUITS
GROUNDING SCHEMATIC
SCALE: NO SCALE
SOLID #2 TINNED COPPER
GROUNDING CONDUCTORS.
GROUND SOURCES INCLUDE
COAXIAL CABLES, ELECTRICAL, ETC.
i
6
B~ RADIUS MIN
o
o
o
BTS AND ANTENNA
GROUND BAR(S)
GROUND BAR DETAIL
SCALE: 1 1/2" ~ 1'-0"
MAIN GROUNDING
CONDUCTOR(S)
=
THE #2/0 GROUND CONDUCTOR SHALL NOT BE INSTALLED IN
METALLIC CONDUIT AND SHALL NOT PASS THROUGH ANY
METALLIC OBJECT THAT ENCIRCLES THE CONDUCTOR, THE
CONDUCTOR SHALL PASS THROUGH WALLS AND FLOORS VIA
PVC SLEEVES. IF THE GROUND CONDUCTOR MUST BE
INSTALLED IN RGS OR EMT THEN CONDUCTOR AT BOTH ENDS.
~
o .
CONDUIT DETAILS
SCALE: 1 1/2" 1'-0.
SEE NOTE 2
SEE NOTE
SEE NOTE .3
UNISTRUT PIPE/CONDUIT
CLAMPS P2558 OR EQUAL
3/8"0 EXPANSION
BOLT AS REQ'D.
UNISTRUT P1000 (OR EQUAL) 1
5/8~ x 1 5/8" WITH
HOT -D!PPED GALVANIZED FINISH
T.O. SLAB
NOTE:
THERE ARE ADDITIONAL CONNECTIONS
TO THE MASTER GROUND BAR THAT
ARE NOT SHOWN IN THIS DETAIL
KEY NOTES
CD INSULATED COPPER GROUND BAR
o (2) WALL MOUNTING BRACKET
(]) (2) INSULATORS
(4) (4) 5/B-11 X ," H.H.C.S.
BOLTS
@) (4) 5/B" LOCK WASHERS
@ #2 AWG SOLID OR STRANDED COPPER
WIRE. BOND TO GROUND BAR. ROUTE
IN DOWNWARD DIRECTION TO GROUND
RING.
NOTE:
GROUND BAR ASSEMBLY AS
MANUFACTURED BY NE~ON
INSTRUMENTS CO., INC., OR EQUAL
=
FOR TWO HOLE LUGS W!SPACING OTHER
THAN THE PRE-DRilLED, CONTRACTOR
SHALL DRILL THE BAR IN THE FIELD.
FULL SIZE BOLTS SHALL BE USED TO
ATTACH LUGS TO THE GROUND BAR.
KEY NOTES
CD
CD
(])
RGS POWER CONDUIT (1-1/2"
MINIMUM).
2" RGS TELEPHONE CONDUIT WITH TWO
BELDEN 6-PAtR TYPE CABLE.
#2/0 STRANDED INSULATED COPPER
GROUND IN 1" RGS CONDUIT, BONDED
ON OPPOSiTE ENDS.
2 01/17/03 REV.PERTOWN.tT-~lf LT. N.~.
1 09/03/02 l$SUEOrORF1UNG S.~. N.~.
0 06/16/02 !SSumrORPRElMlARYREVlEW S.I.4. ,..
"'. DATE DESCRIPTION ~~v" C"'
"
APPROVALS SIGNATURE om
WcrSTREAI.4
OWNEll/lAt()LORO
LEASING/SAC
Rf ENGINEER
ZONING
CONSTRUCTION
WILLIAM F, COLLlN~ AlA
ARC HIT E C T S. LLP
JH "IBCHNOLOGY DRIVB SBTAUKET, NY am
VOICE . tiD-6lI9-lMSO PAX . g~
. t t,: / /. ....fc.t..c..
--:'~ -.::;-.,
,{f/r-.
. y..;, < /;;:.' ,-c' .,.
/'"L.).cr''' ,,~:~
/J;.+,\(~~.~...:J;;~)~J
,.. ..i~" _..__
, . \. . ,-~..-
. . .
----._~
PROJECT If 02 4900
~~M~~C~f.~:~ct
asanll}el'lllClf
OmnipoinIr~Nelwcrl2,LLC.
.4 Sylvan Way. Panlppany, NJ 07054
Omnlpalnt Communications Inc. is a subsidiary
of VaiceStream Wireless Corporation
SITE INFORMATION
CUTCHOGUE
71855 COUNTY ROAD 48
CUTCHOGUE. N.Y. 11935
LI-13-544-A
DESIGN TYPE
NEW BUilD
COlOCA TION MONOPOLE
SHEET TITLE
NEW BUilD
COlOCA nON MONOPOLE
SHEET NUMBER REV,
E-4
2
JUMPER FROM ANTENNA
JUMPERS
WEATHERPROOFING
KIT (TAPE, BUTYL &
SCOTCH COTE)
CONNECTORS~
"-
\ I
1---
/ ----(
\
\
"
GROUND WIRE TO BE
CRIMPED TO #2 SOLID
TINNED GROUND WIRE
TO GROUND BAR
II
STD. CABLEWAVE
GROUND KIT (TYP.)
COAXiAl CABLE
BETWEEN ANTENNA
AND BTS JUMPERS
JUMPER CABLE
FROM BTS
CABLE GROUNDING KIT DETAILS
SCALL NO SCALE
.
~ JUMPER C~~~CONNECTORS
, <I
~ COAXIAL CABLE
STEP!
STEP 2
1M 1N
H H
.'''~(1
LAYER)
6
STEP 3
~~
.::,:,:J'~ 6
~ BUTYL TAPE (ALSO CALLED
MASTIC OR TAFFY TAPE)
.
~ .....~
. "'"'' "lJiIk1~~~~::~: ~~. TAPE,
STEP 4 AND 3 LAYERS 3/4" TAPE. ALL
TAPE WITH MINIMUM 50';; OVERLAP)
COAT WITH 3M SCOTCH COAT.
.
ANTENNA CABLE WATERPROOFING DETAIL
SCALE: NO SCALE
CD
~
:u
............
(
'-
" V
\ E
R
\ ~
/ ~
/L
./
NOTE:
DO NOT INSTALL GROUND KIT AT A
BEND AND ALWAYS DIRECT GROUND
WIRE DOWN TO CIGBE.
NOTE:
VERTICAL CONNECTIONS SHOULD BE TAPED
FROM THE BOTTOM UP TO MOVE WATER
AWAY FROM CABLE CONNECTION.
.tillIf:.;
ALL CABLE CONNECTIONS TO BE WATERPROOFED
AS ILLUSTRATED WITH ELECTRICAL TAPE, VAPOR
SEAL (BUTYL TAPE), THREE LAYERS OF
ELECTRICAL TAPE AND SCOTCH COAT.
KEY NOlES:
CD PANEL ANTENNA
CD @ TYP. ANTENNA MOUNTING PIPE
@) 1/2" COAXIAL JUMPER
0 REFER TO GROUNDING KIT DETAIL.
DO NOT INSTAll ON BENDS
@ @ CALD WELD TYPE "vS"
@ ANTENNA COAXIAL CABLE (TYP
@) FOR 2)
0 TO COMMUNICATION CABINET
@ 2 BARREL HYDRAULICALLY
COMPRESSES CONNECTION PANOUIT
0 @ CATALOG # CTAP 2-2X
@ #6 INTERNAL GROUND
CONDUCTOR FROM GROUNDING KIT
@ TO #2 SOLID
@ @ #2 SOLID TINNED COPPER
GROUNDING CONDUCTOR a" MINIMUM
@ RADiUS
0 (j]) 2 BARREL HYDRAULICAllY
COMPRESSED CONNECTION PANDUIT
@ @ CATALOG # CTAP 2-4Q
@ TO NEXT PANEL ANTENNA IN SECTOR
(j]) @ ~ TO SECTOR GROUND BAR
ANTENNA GROUNDING SCHEMATIC
SCALE: NO SCALE
01/17/03 REV. PER TOWl<l & T-l.IOElU
og/03/02lSSUEDFORFlUNG
o 08/16/02 lSSUED FORPRElMIWlY REVlEW
NO. DATE DESCRIPTION
LT. N.~
S.~. N.~.
S.~ N.M.
DR CHK
BY BY
DATE
APPROVALS
SIGNATURE
VOICESTREAM
OIlltlER,..u.NOLORD
LEASING/SAC
RF ENGINEER
ZONING
CONSTIWCTION
WILLIAM F. COLLINS, AlA
ARC HIT E C T S. LLP
JH lB:HNOLOGY DRlVB IBTAlJXET, NY D733
VOICE I 61l~ FAX I 61l--61J9--S4S9
. t t ,: II ww. ..1 c ala. c..
..-._~~,
~n""i. ..,~C.
,/<,~>,
! /':i "''{ \
'.. V..j
,.. 'I j
/j1~.~_..\
PROJECT # 02-4900
~~M~~~r.~~~ct
as on aqenl for
~lfaciliiesNl!lwork2,LLC.
-4 Sylvan Way, Parsippany, NJ 0705-4
Omnipoint Communications Inc. is 0 subsidiary
of VoiceStream Wireless Corporation
SITE INFORMATION
CUTCHOGUE
71855 COUNTY ROAD 48
CUTCHOGUE. N.Y. 11935
L1~ 13-544- A
DESIGN TYPE
NEW BUILD
COLOCA TION MONOPOLE
SHEET TITLE
ANTENNA & CABLE GROUND
& WATERPROOFING
SHEET NUMBER REV,
E-5 2