Loading...
HomeMy WebLinkAbout30458-Z FORM NO. 4 TOWN OF SOUTHOLD BUILDING DEPARTMENT Office of the Building Inspector Town Hall Southold, N.Y. CERTIFICATE OF OCCUPANCY No: Z-31625 Date: 06/21/06 THIS CERTIFIES that the building ADDITIONS/ALTERATIONS Location of Property: 25 PRIVATE RD #12 SOUTHOLD (HOUSE NO. ) (STREET) (HAMLET) County Tax Map No. 473889 Section 78 Block 6 Lot 9.2 Subdivision Filed Map No. Lot No_ conforms substantially to the Application for Building Permit heretofore filed in this office dated JUNE 30, 2004 pursuant to which Building Permit No. 30458-Z dated JUNE 30, 2004 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is ADDITIONS & ALTERATIONS TO AN EXISTING SINGLE FAMILY DWELLING AS APPLIED FOR. The certificate is issued to DONNA M COOK (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL N/A ELECTRICAL CERTIFICATE NO. 1123201 06/05/06 PLUMBERS CERTIFICATION DATED 04/12/06 H2M LABS, INC. hor zed Signature Rev. 1/81 Form No.6 TOWN OF SOUTHOLD R 18 BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings, property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead. 5. Commercial building, industrial building,multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9, 1957) non-conforming uses, or buildings and "pre-existing" land uses: 1. Accurate survey of property showing all property lines, streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied, the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$25.00, Additions to dwelling $25.00, Alterations to dwelling $25.00, Swimming pool $25.00, Accessory building$25.00, Additions to accessory building$25.00, Businesses $50.00. ' 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy- $.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy -Residential $15.00, Commercial$15.00 Date. �� �` New Construction: QOld or Pre-existing Building: ��(check one) / Location of Property: �� / 1"t✓Qr� � /� s Ll �Q House No. Street Hamlet Owner or Owners of Property: b 0/I/k iq., (fA o K Suffolk County Tax Map No 1000, Section 7$? Block $ Lot , oC Subdivision Filed Map. \� Lot: ,(J Permit No. �SO —� Date of Permit. Applicant: Byww C"/OOk Health Dept. Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: (check one) Fee Submitted: $ ?p , OD 6��-'7 6N 33 Applicant Signature C6--a3l&_2s FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 30458 Z Date JUNE 30, 2004 Permission is hereby granted to: DONNA M COOK 6900 MAIN BAYVIEW RD SOUTHOLD,NY 11971 for ADDITIONS AND ALTERATIONS TO AN EXISTING ONE FAMILY DWELLING AS APPLIED FOR. THIS PERMIT REPLACES BP#28549 . at premises located at 25 PRIVATE RD #12 SOUTHOLD County Tax Map No. 473889 Section 078 Block 0006 Lot No. 009 . 002 pursuant to application dated JUNE 30, 2004 and approved by the Building Inspector to expire on DECEMBER 30, 2005 . Fee $ 306 . 30 Au rized Signature ORIGINAL Rev. 5/8/02 � rJ�rJ�rJ�rJ�rJ�r�rnr.ncncnrl�nrJ�rJ�rJ�r�rJ�rJ'rJ��nrrJrJ�rJ�cn�nr�rJ�rJ�rJ�rJ�r�r�rJ�rJ@ncncnrJ�rJ�rJ�rJ�rJ�rJ�rJ�rJ�r.n�nrJ�rJ�rJ�cPrJ�rJ�rJ�rJ�rJ�rJ�rJ�rJ�r�r�r�rJ� o BY THIS CERTIFICATE OF COMPLIANCE 5 5 NEW YORK BOARD OF FIRE UNDERWRITERS5 5BUREAU OF ELECTRICITY _ 5 5 40 FULTON STREET — NEW YORK, NY 10038 SCERTIFIES THAT 5 5 Upon the application of upon premises owned by 5 TUCKER ELECTRIC, INC DONNA COOKr77 �j 1800 HARBOR LN./BOX 1065 6900 MAIN BAYBIEW RD 5 CUTCHOGUE, NY 11935, SOUTHOLD, NY 11971 5 5 c5 5 �j Located at 6900 MAIN BAYBIEW RD SOUTHOLD, NY 11971 5 C7 5 Application Number: 1123201 Certificate Number: 1123201 C5 Section: Block: Lot: Building Permit: BDC: NS11 �5 Described as a Residential occupancy, wherein the premises electrical system consisting of 5 electrical devices and wiring, described below, located in/on the premises at: 5 5 First Floor,kitchen,Outside, 5 5 A visual inspection of the premises electrical system, limited to electrical devices and wiring to the extent detailed 5 5 herein, was conducted in accordance with the requirements of the applicable code and/or standard 5 5 promulgated by the State of New York, Department of State Code Enforcement and Administration, or other S 5 authority having jurisdiction, and found to be in compliance therewith on the 5th Day of June,2006. 5 5 Name QTY Rate Ratin Circui[ Type 5 5 Alarm and Emergency Equipment 5 5 Sensor 1 0 Carbon Monoxide 5 5 Sensor 5 0 Smoke rr5 5 rj Wiring and Devices Outlet 6 0 Fixture 5 5 Fixture 6 0 Incandescent 5 5 Outlet 12 0 General Purpose 5 Receptacle 9 0 General Purpose 5 Switch 6 0 General Purpose 5 5 Receptacle 1 0 20 amp Laundry 5 5 Receptacle 4 0 GFCI 5 5 S 5 5 5 seal I of I 15 5 This certificate may not be altered in any way and is validated only by the presence of a raised seal at the location indicated. 5 5 O cnrJ�rJ�rs�nt :iilJJVIl1lrJ�rJ��nr��l1lrJ1�cPrJ'r�rJrJ�r rL3r ncnL3fr3L3rC3J o w _ ti] cPrJ�rJ�cP�ncl��nr��l-rJ��.I�rJ@ncnrJ�rJ@nrJ'r1c.nrJcPrJ�rJ@Pr�rJc.nrJ�rJ�r�rJcPrJ�cnrJ�rJ�rJ�r�tPrJ�rJ�rJ�cfrPr.Pcn�nrJ�rJ�c.rrJ'rJ�rJ�rJ@PrJ�rJ�cPc.fc.fcJ�rJ� o BY THIS CERTIFICATE OFIRE COMPLIANCE UNDERWRITERS 5 5 NEW YORK BOARD OF5 5 BUREAU OF ELECTRICITY r5 CC5 40 FULTON STREET — NEW YORK, NY 10038 I57 CERTIFIES THAT 5 Upon the application of upon premises owned by 5 RAYNOR FRANK L. DONNA COOK e 5 1800 HARBOR LN./BOX 1065 6900 MAIN BAYBIEW RD 5 5 CUTCHOGUE, NY 11935, SOUTHOLD, NY 11971 5 Located at 6900 MAIN BAYBIEW RD SOUTHOLD. NY 11971 5 Application Number: 1123201 Certificate Number: 5 Section: Block: Lot: Building Permit: BDC: NS11 e Described as a Residential occupancy, wherein the premises electrical system consisting of 5 5 electrical devices and wiring, described below, located in/on the premises at: 5 5 5 c5 A visual inspection of the premises electrical system, limited to electrical devices and wiring to the extent detailed rj herein, was conducted in accordance with the requirements of the applicable code and/or standard promulgated by the State of New York, Department of State Code Enforcement and Administration, or other 5 5 authority having jurisdiction, and found to be in compliance therewith on the Day of 5 5 Name OTY Rate Ratine Circuit Type 5 5 5 5 5 5 5 5 5 5 55 5 sea/ 5 5 5 e5 1 of 1 5 This certificate may not be altered in any way and is validated only by the presence of a raised seal at the location indicated. 5 5 U2M "US, INC. 575 Broad Hdba Road,Melville NY 11747 (631)694.9090.FAX(631)420.84%NYSDOH ID#10478 LABORATORY RESULTS HARRY GOLDMAN WATER TESTING Sample Information... MAIN ROAD Lab No. : 0604157-001A Type : Solder MATTRUCK,NY 11952 Origin: Distribution Attn To 631-298-4640 Routine Federal ID Client ID.: DONNA COOK Collected :4/4/2006 9:55:00 AM Point No: 4 6900 MAIN BAYVIEW RD,SOUTHOLD Received :4/4/2008 1:30:00 PM Location : SOURCE(CWL-KS)(30458-Z)(1000-78.6-9.2) Collected By :JD99 EXTENSION Copy : Original CC Parameter(s) Results Qualifier D.F.. Units Limit Method Number Analyzed Lead 0.01 1 % 0.2 SV4601 OA 04/12/2006 10:19 AM Result(s)reported meet(s)Regulatory Limit(s). ( flagged with * Exceed Regulatory Limit(s). Limit rested. D.F.=Di D.F.=Dilution Factor Date Reported: 4/12/2006 Page 1 of 1 Laboratory Manager OF SOUryo6 cou�m TOWN OF SOUTHOLD BUILDING DEPT. 765.1802 IN ION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] 1 UL [ ] FRAMING / STRAPPING [VJIFINA(f)!5�) [ ] FIREPLACE A CHIMNEY [ ] FIRE SAFETY INSPECTION REMARKS: 1 DATE © INSPECTOR ypF SOUTy�� TOWN OF SOUTHOLD BUILDING DEPT. 765.1802 INSPECTION [ ] FOUNDATION IST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING [ INAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION REMARKS: DATE INSPECTOR �o��,oe souryo�o TOWN OF SOUTHOLD BUILDING DEPT. 765.1802 INSPECTION [ ] FOUNDATION 1 ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING ) FINAL—gLAtt. I ONLY [ ] FIREPLACE & CHIMNEY/[ `] FIRE SAFETY INSPECTION REMARKS: p 30 Ll . DATE C ' � � INSPECTOR 'i,2� 765.1802 BUILDING DEPT. gFRNG SPECTION ION 1 ST [ ] ROUGH PLBG. ] ION 2ND [ ] INSULATION [ ] FINAL [ ] FIREPLACE & CH NEY [ ] FIRE SAFETY INSPECTION REMARK f DATE �161VINSPECT M-1802 BUILDING DEPT. INSPECTIO [ ] FOUNDATION IST [ RO H PLBG. [ ] FOUNDATION 2ND [ INSULATION [ ] FRAMING [ ] FINAL [ ] FIREPLACE & CHIMNEY ARKS: DATE V INSPECT `I 71 J M-1802 BUILDING DEPT. INSPECTION [ J FOUNDATION 1 ST [ ] ROUGH PLBG. [ ] FO DATION 2ND [ J INSULATION [ FRAMING ( ] FINAL [ ] FIREPLACE A CHIMNEY REMARKS: DATE 07 3 INSPECTOR /�/ ?�w zee 6&7 2, L) 6 c° ^7G 7GS-1802 BUILDING DEPT. INSPECTION [ ] FOUNDATION IST [ ] ROUGH PLBG. [ ] F NDATION 2ND [ ] INSULATION [ FRAMING ( ] FINAL ( ] FIREPLACE & CHIMNEY REMARKS: ' - Ad-ot;c2w,le� ti DATE oT INSPECTOR OF SOUIyo� 3 ° `ts � z0 �yoouen TOWN OF SOUTHOLD BUILDING DEPT. 765.1802 INSPECTION [ FOUNDATION IST [ ] ROUGH PLBG. [/ \] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION REMARKS: 1,7 -- - � -� -- c. � 0 ^3 ' 05 r DATE INSPECTOR 1 045✓ 765.1802 BUILDING DEPT. INSPECTION / Wk ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] SOLATION [ ] FRAMING WNAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION REMARKS: aC� .Ks 0, � DATE c� INSPECTOR - c FOUNDATION (2ND) __�✓ ��_� - " iii -///_ . __ i �. W-5 DC7 tai • . 1 ��i//.�/,i!J4�1�//i ��� //tom �� -- /�: M rj 0 • W4O • -'N 1 I:N ; ��1 APPEALS BOARD MEMBERS o�OSpFFO�,�coG Southold Town Hall Gesard P. Goehringer, Chairman �� 'y� 53095 Main Road Lydia A. Tortora c P.O. Box 1179 George Horning Southold, New York 11971-0959 Ruth D. Oliva T' �!� ZBA Fax(631) 765-9064 Vincent Orlando �Ol * `�� Telephone(631) 765-1809 http://southoldtown.northfork.net BOARD OF APPEALS TOWN OF SOUTHOLD FINDINGS, DELIBERATIONS AND DETERMINATION MEETING OF JUNE 20, 2002 Appl. No. 5118- Donna M. Cook. Property Location: 6900 Main Bayview Road, Southold; Parcel 78.-6-8. BASIS OF APPLICATION: Building Department's March 3, 2002 Notice of Disapproval for the reason that applicants' proposed addition does not meet the code requirements for a minimum 40 ft. front yard and single side yard of 15 feet. AREA VARIANCE REQUESTED: Applicant is requesting a variance under Section 100-244B for an addition to the existing dwelling on the second floor, which will be within the nonconforming footprint of the dwelling, presently 26 feet from the front line, and single side yard of 11 feet. (Please see map disapproved by the Building Department of record for additional details.) FINDINGS OF FACT The Zoning Board of Appeals held a public hearing on this application on June 20, 2002, at which time written and oral evidence was presented. Based upon all testimony, documentation, personal inspection of the property and the area, and other evidence, the Zoning Board finds the following facts to be true and relevant. PROPERTY DESCRIPTION: The applicant's property is located on south side of Main Bayview Road in Southold. The lot is improved with a one-story frame house and accessory garage, as shown on the September 20, 2001 survey, revised October 10, 2001 by John C. Ehlers, L.S. REASONS FOR BOARD ACTION: In accordance with the review standards set forth in Town Law 267b-3 "area variances," the Board has considered the benefit to the applicant if the variance is granted, as weighed against the detriment to the health, safety and welfare of the neighborhood and community by such grant, and determines that: 1. Grant of the area variance will not produce an undesirable change in the character of the neighborhood or detriment to nearby properties. The setback of the existing house is nonconforming at 26 feet, and a second story addition would not be possible without a variance. Some variance from the setback requirement is necessary for a second story. 2. The benefit sought by the applicant cannot be achieved by some method, feasible for the applicant to pursue, other than an area variance. The house as exists is nonconforming at 26 feet. A second story addition is not unreasonable. 3. The variance granted herein is not substantial. The setbacks already exist and are not being further reduced. 4. The alleged difficulty has not been self-created. Page 2—June 20,2002 ZBA Appl.No. 5118-Donna Cook Parcel 78.-6-8 at Southold 5. The variance granted will not have an adverse effect or impact on the physical or environmental conditions in the neighborhood or district. No evidence has been submitted to suggest that this minor variance will have an adverse impact on physical or environmental conditions in the neighborhood. 6. Grant of the requested variance is the minimum action necessary and adequate to enable applicant to enjoy the benefit of a second-story addition with rear deck, while preserving and protecting the character of the neighborhood and the health, safety, and welfare of the community. BOARD RESOLUTION ACTION OF THE BOARD: In considering all of the above factors, and applying the balancing test under New York Town Law, motion was offered by Member Oliva, seconded by Member Horning, and duly carried,to GRANT the variance as applied for. This action does not authorize or condone any current or future use, setback or other feature of the subject property that violates the Zoning Code, other than such uses, setbacks and other features as are expressly addressed in this action. Vote of the Board: Ayes: Members Goehringer (Chairman ortora, Ho , Oliva, and Orlando. This Resolution was duly adopted (5-0). GGA/19 X ,' i /�� G and P. Goehringer,Chairman 6-26- i TOWN OF SOUTHOLD PROPERTY RECORD CARD /fir OWNER STREET ZS VILLAGE DIST. SUB. LOT FORMER OWNER N 00 .e,�d.. k4 E _L/ Q y AC /T y SW TYPE OF BUILDING ° lie 1119s RES. /� SEAS. VL. FARM COMM. CB. MISC. Mkt. Value LAND IMP. TOTAL DATE REMARKS i. a �0"D e2 7 to.1 :3 `-1 & a. 4c H,?B T /06,J 2 oU � /S 0 b l� 9 - P '* oo - Q, I�eA4 ; - L, <a � $� , f }�, � �� 3oo,( 0 0 7tO 1 a -) 9g—L /- -, AGE BUILDING CONDITIONq / , mj �C%l . f/ Lc _Gj �Gt NEW NORMAL BELOW ABOVE Z u t © /S e S}(- FARM Acre Value Per Value Jv Acre Tillable 1 Tillable 2 Tillable 3 vVoodland Swampland FRONTAGE ON WATER 3rushlond FRONTAGE ON ROAD U House Plot DEPTH BULKHEAD Totaio. r r+ DOCK ■■■■nw� ■■■■■■■■■■■■■■■■■■■ COLOR Er ■■■■■moi I■d'1■■■■■■■■■■■■■■■■■ Irv- TRIM ■■■■0�■�1■■I■■■■■■■■■■■■■■■■� ■■■■■■■�a■■■■■■■■■■■■■■■■■■ ii■■■iiii=iiiiiiiiiiiiiiiiii= FoundationBath DinetteS ExtensionExtension en ent ea Floors K. 300 Pt t Interior Finish LR Extension Ext. Walls ® • ' Type RoofI Rooms lst Floor - BR. ecreation Room Rooms 2nd Floor FIN. B. Porchi Porch Dormer Driveway Breezeway Garage X 7 4 Il �- • • •Total ��� - TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying 7 TOWN HALL Board of Health SOUTHOLD,NY 11971 U �S—� 3 sets ofB ' P�_ TEL: 765-1802c�,�, � Survey t PERMIT N07�7�`t'� Check Septic Form N.Y.S.D.E.C. �7 Trustees Examined Contact: Approved 9XI,20 Mail to: Disapproved a 3 02- Phone:7(eS^tn - r�9s`p Building Inspector APPLICATION FOR BUILDING PERMIT 6LDG. CF^7 GJ 20� 7�'t'iFi F F:?iJT"rfGLD Date INSTRUCTIONS a.This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 3 sets of plans,accurate plot plan to scale.Fee according to schedule. b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas, alyd waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what-so-ever until a Certificate of Occupancy is issued by the Building Inspector. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York,and other applicable Laws,Ordinances or Regulations, for the construction of buildings,additions, or alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code,ho ing code,and regulations,and to admit authorized inspectors on premises and in building for necessary inspections. ignature of applicant or name,if a corporation) ®0 (Mailing addressli t) !1/ State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician,plumber or builder Name of owner of premises iti iq (as on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. 1' Plumbers License No. r Electricians License No. Other Trade's License No. 1. Lo7019O land o>Mlu opo ed work will be cjone: �iAVrl I etd ,fid House Number Street I Hamlet County Tax Map No. 1000 Section /000 Block 79'' t --Lot Subdivision Filed Map No. )t. "V. Lot (Name) 2. State existing use and occupancy of 1relmses and irate ded use and occupancy of proposed cQustmction: a. Existing use and occupancy /torn-2_ W Co-�C�. U4-P- �° D/i�% o,,- 1� b. Intended use and occupancy 3. Nature of work(check which applicable): New Building __Addition Alteration Repair Removal Demolition Other Work f (Description) 00 4. Estimated Cost 1 °io Fee / (to be paid on filing this application) 5. If dwelling, number of dwelling units ` Number of dwelling units on each floor If garage, number of cars 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures,if any: Front Rear Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories. 8. Dimensions of entire new construction: Front Rear Depth Height Number of Stories � 2 I 9. Size of lot: Front 0 Rear 0 Depth ✓150 10. Date of Purchase Z Name of Former Owner 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation: 13. Will lot be re-graded /v 1 (Will excess fill be removed from premises: YES �O /_ 14.Names of Owner of prgmises'bo vc KAddress 6 fOO fkaj� t�WIVPhone No. �?6��a_L Name of ArchitectL .earAddress ,G�tav 4 7-iy. Phone No x.77— (25a Name of Contractor—=3, Address Phone No. 15. Is this property within 100 feet of a tidal wetland? *YES NO // IF YES, SOUTHOLD TOWN TRUSTEES PERMITS MAY BE REQUIRED 16. Provide survey, to scale,with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below,must provide topographical data on survey. STATE OF NEW YORK) SS: COUNTY OF ) b0/Ot)f+ 14. 000k- being duly swom, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)He is the 0 W tj 6^--t (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief and that the work will be performed in the manner set forth in the application filed therewith. Sworn to before me this day of 200 !' ` Notary Public Signature of Applicant ELIZABETH A STATHIS NOTARY PUBLIC,State of New York No.01 ST6o08173,Suffolk Col�nty Term Expires June 8,20_ gpFfO(,� Albert J. Krupski, President ��� CQ Town Hall James King,Vice-President h� Qy� 53095 Route 25 Artie Foster Go O P.O.Box 1179 Ken Poliwoda Ve Southold,New York 11971-0959 Peggy A. Dickerson �J/ Q Telephone(631) 765-1892 Fax(631) 765-1366 BOARD OF TOWN TRUSTEES TOWN OF SOUTHOLD March 30, 2005 Donna Cook 6900 Main Bayview Road Southold, NY 11971 Re: 6900 MAIN BAYVIEW RD, SOUTHOLD Lot 78-6-9.2, 9.3 Dear Ms. Cook, The Board of Trustees is in receipt of your letter of January 27, 2005. The Trustees have inspected your property and have determined that it is not fresh water wetlands. There are no freshwater wetland indicator plant species on your property. The plan that you describe in your letter to drain the area has been approved by Trustee Artie Foster. Therefore, your property does not come under the jurisdiction of the Board of Trustees. We will send a copy of this letter to the Planning Department, Building Department, and Zoning Board of Appeals. Please contact this office with any further questions. Very Truly Yours, L /J Albert J. Krupski President, Board of Trustees Cc: Zoning Board of Appeals Southold Building Department Southold Planning Department AJK/hct 1:NERGY COLIC CALCULATIONS (For Non—Electric Heat) Design CriL-eria G , UoO Degree'.Days O.A. lour I•A. .7U°F FOR: '00P n 47 ZOO PER: Co.lc G 50 MCiA VKv .Sa .) 446/ DA'Z'ED' Z�f OL AREA DESIGN THERMGL REMARKS SUBSYSTEM "U" RATING C;xLerioe Walla (Opaque) cj� p b7-7 6� _ Glazing Doors JO J? .. Cciliuy/Hoof (opaque) -737 0j SkyliyllLs Floor / y ,L co' foundation Walls Slab Insula Lion TOTAL +6 Notes: 9uilding Envelope Systems to meet requirewenLs of 7015. 2 HVAC Equipement to meet requiremenL•s of-, 7015. 11 nVAC Systems to meet requirements of 70.15. T2 Duct Systems to meet requiremeftLs of 7015 . 13 VenL'ilaL'lons Systems to meet requirements of 7015 . 14 lusulaL•lou of pipiny .SysL'ems L'o meet requirements of 7U15 . 15 Service Water Heating Systems & Equipment to meet requirements of '7015. 21 ElecLrlcal & Lighting Systems & Equipment to meet requirements of 7015 . 31 F OF NEW y To the best of my knowledge, belief, & professional judgement, these plans are W compliance with L•he code . r 032254-1 �aV aA�OFESSIONP� 2 2- BUILDING PERMIT EXAMINER CHECK LIST DATE REVIEWED: 3 / /01— APPLICANT NAME�A,Na Coo,t .DATE SUBMITTED: z /LS/0� SCTM# DISTRICT: 1,000 SECTION: BLOCK: to LOT: f 2 w STREET:005900 CITY:�SOUV-140&.e SUBDIV. NAME: PROJECT DESCRIPTION: �aoi�ol��/�c�X4T7o✓s ARCHITEC NGINEER: FAST TRACK? �� SINGLE&SEPARATE CERTIFICATION-REQUIRED? Alo NOTES: — LOTS 40,000SF-100-24.Lot recognition.(CREATED before June 30,1983),UNDERSIZED LOTS FROM JAN.1997 100-25.Merger.(A nonconforming at any time after 7/1/83) ZONING DISTRICT: R-5/d CONFORMING? e0 qo 000 lam. 8`i6 0 REQ.LOT SIZE: ACT. LOT SIZE: REQ.LOT COV. a°% ACT. LOT C 7 l REQ. FRONT `/0 PROP. FRONT Z cQ SIDE i r 3 - ACT. SIDE REQ.REAR fo PROP. REAR a WATER FRONT? A9 DE CRIPTION: PANEL #: FLOOD ZONE AE 17 AGENCY PERMITS REQUIRED FOR REVIEW APPEOXALS RE UI SUFFOLK COUNTY HEALTH DEPT: YES O (BED#): DT / / P #: 10- NEW YORK STATE DEC: PRE-DEC 9/1/75 YES o SOUTHOLD TOWN TRUSTEES: S or TOWN ZONING BOARD APPROV r NO TOWN PLAN. BOARD APPROV S or TOWN HISTORICAL PRE (SPLIA): YES O NYS ENERGYOE OR NO : + EGRESS 18 H mm.? 4 sq total VENTS . FT. x 4% LIGHTS . FT.x 8% BUILDING PERMITS OPEN/EXPIRED: BP 22 06'� -Z/C/0 Z- c)�3 o HAVE PRE CO'S : Y OR N BP -Z/C/0 Z- , NOTES: FEE STRUCTURE: FOUNDATION: SF FIRST FLOOR : 33 i SF SECOND FLR : /0 V -0 SF INIT OTHER TOTAL TOTAL: �.� ,� SF FEE FEE FEE 'OT( /;?/ SF)- ( 8, SF)=.g/ SFX$3 O =$/r f; 3a +$ /-J +$ =s 3 3 O gm,PC �r BUILDING.PERMT REVIEW CHECK.LIS.T TE REVIEWED: 9 ! /01 • DATE SUBMITTED: L 41-5 /01 APPLICANT NAME: (le OK /J o.=� G� ,ane—dk�,� SCTM#--- DISTRICT: 1,000 SECTION: BLOCK: LOT: STREET: l FOO A4,,,1 �a�/ulr� CITY: S. 1 SUBDIV. NAME: PROJECT DESCRIPTION: AD ALT ACC OR N/D: AS ARCHITECT/ENGINEER: FT TRAck: YES ORNO SINGLE& SEPARATE CERTIFICATION-REQUIRED: YES o N OTES: LOTS 40,000SF-100-24.Lot recognition.(CREATED before June 30,1983),UNDERSIZED M JAN.1997 100-25.Merger.(A nonconforming at any time after 7/1 ZONING: PERMIT ESTIMATE AMOUNT:_$ 900 .00 PERMIT USE: EXISTING: S��Q INTENDED:Srz ZONING DISTRICT. R80 AC CONFORMING: YESo N REQUIRED LOT SIZE:16,< SQFT WHERE ACTUAL LOT SIZE FROM?TAx CARD ACTUAL LOT SIZE:2g7o& SQFI REQUIREDrE s/- REQUIRED 14,F- REQUIRED IsT FOUND:FRONT:3S 'PROPO D:/8' SIDE YD: /O '/-2,L' PROPOSED: // '/ ' REAR �S 'PROPOSED: 1m FOUND:FRONT: ACTUAL: SIDE YD: '/ ' ACTUAL: '/ REAR: ' ACTUAL: ' LOT COVE E: ALLOWED:,2d % EXISTING: sf % NEW: sf % TOTAL:1-4e& sf 9 % CORNER? S R NO WATERFRONT"?ER FRONT? YES o DESCRIPTION: FLOOD CO'm LIANCE ZONE: PRE-FIRM 3/18/80 PANEL _ FLOOD ZONE: Ate-& , AGENCY PERMITS REQUIRED FOR REVIEW INCLUDED IN APPLICATION TOWN SPETIC PERMIT: YES or SUFFOLK COUNTY HEALTH DEPT: YES or>Q; (BED#): DTE:—/ % PERMIT#:R10- APPROVALS RE UIRED: NEW YORK STATE DEC: PRE-DEC 9/1n5 YES or SOUTHOLD TOWN TRUSTEES: or O TOWN ZONING BOARD APPROVYES rN_O` .� s /'/ego Zf¢ .G-�d,.•�,,� TOWN PLAN. BOARD APPROVAL: S orU TOWN HISTORICAL PRE (SPLIA): YES or NYS ENERGY: YES OR NO EGRESS: VENT: LIGHT: BUILDING PERMITS OPEN/EXPIRED: BP2,2-� -Z/C/0 Z- HAVE PRE CO'SY�R N BP . _Z/C/0 NOTES: /^+GOa a �a^c Cvt FEE ST UCTURE: FOUNDATION: SF FIRST FLOOR : /6,7-8 SF SECOND.FLR : /66-S- SF INIT OTHER TOTAL TOTAL: SF FEE FEE FEE TOT( SF)- L SF)= SF X$ _$ +$ +$ ao =$ r 9 J/�� � TaS ♦ COaKi � OKE �QG/L % SS ♦�I �sso�7�-.-� y/�[.�tS S ca�� 0-4 Cl 14e-1 Fel 2- 5URVEY OF PROPERTY IN SITUATE: SOUTHOLD /`�% TOWN: SOUTHOLD w E � � f7 SUFFOLK COMM NY SURVEYED 09-20-01, 10-10-01 SUFFOLK COUNTY TAX # 1000 Sts 1000 - 9 /' 9`bl' / CERTIFIED TO: DONNA GOOK ; �p \ �G�s o F 4� 1Alll` 2}4 'Cti` 'Y/ 1 , O ?% V l 1 O ' w I / ko _°� � ® Q 2 °Q� / / w b es o w ' b / ti ' h0 / / / / / / / / / / / / / / ry o R qti 'v `` Ir Rim F�<O V, aQ UTro OF NSW G Ell�p�O� sc NOTES: I yh. ■ MONUMENT STAKE AREA = 20,5% SF OR 0.48 ACRES s 5� y. e' 1; I:I`,.,.: INSPECTION AND EVIDENG EBY OTSEPTIC, SYSTEM 5HOYqN FRM HERS JOHN C. EHLERS LAND SURVEYOR j 6 EAST MAIN STREET N.Y.S.LIC.NO. 50202 6RAPHIG SCALE 1"= 30RIVERHEAD,N.Y. 11901 369-8288 Fax 369-8287 REF.\\Hp server\d\PROS\01-171.pro C-0 o / IDERWRITERSCERTIFICATE t� REQUIRED LIZ OCCUPANCY OR USE IS UNLAWFUL Z Ca ,,< WITHOUT CERTIFICATE DEPARTMERT AT _ OF OCCUPANCY TO t PM NIS ToPRO WOO—DEIE � xsrTING I FNPOUREDCONCREiE 2- 2v 7.1 b ` ' ' 1 AMINO Jt FLUMbINO ALARM DEVICES _ i ! I ULATIO ASAO PART. 21.1 { L FINAL - C NSTRUCTIOM MUST N.Y.S UI(�DWI &CW)E< ICOMPLIgrE l ALL ONSTR CTTIIONSMALL MEET _ 2STiTA�pNSTRUCTION Q ENERG ROVI - 2 y 3 2 I S$ New CODES. NOT RESPONSIBLE FO DESIGN OR CONSTRUCTION ERRO ME6GE C SCA EAS JR QUIRfD 6 ART. 14 0f _ }f CERT/FICATI ON LEAD MAMECONTENT BEFORE NFC4E OF OCCUPA CY r I dLDE#USED IN WATE S rT I f E=XCEED 0 Of 1% LE j �� OF NEW Yo f 1 1 opper u 5,9 is used t r wit i tributing - a s e , pip 1 shall be sF 032z54-i ves r 90 F ONP��T UND RREQ ITEE S EDRTIFICATE ► PLUMBING - - .-- i ALL PLUMBING VAikS E. A WATER LINES NEED o ple- _ TESTING BEFORE COVERINGRf L - • �phn q CoStC — PROVIDE ANTI-SCALD AND/OR Sc THERMAL SHOCK PREVENTING DEVICES AS TO PART. 902.6(K) N.Y. STATE BUILDING CODE. A i 3u3r� i �i F � f ti Z LN3L i 2 2 4 3t sF 032254.1 V I o e 9OFESSlONP LA 01 EW i �- 4h �G N'E a/ — .......... 2/4/02 f � � I ! f 3 J 310 1 2y 210 Ze68 r I r .. . rc.09f i Eq2 2 0321501 A9UFESSIOti ------------------ 1� _ _ r N E lt/ `317 &fW o I spa c � ! j Eersr 2"rg` 7G se I� 2 e8` /G o i �o eszzsa-1 CO I n I EarS•f I+ 90FESSION� a Eats) I i j I ' /4- SfxtnPahfng I EK,S/ — F — — — - - — — — — — — - -- tst-6` A►t�'W ,'��. — _� - _ 34'. x{'' ;Exrs4,ns � �pny, � Cool E---- ---, tee / -- M c,h $a y v,,r C J 7 3'-0 3`�'• p4!u -••�-••T-••— i _ 1 y 573 ryl 17-i A/ew S4al�s . �q� 4L� 2 N i L II fjf, . . fi W2254I V� L VNJ ♦ N ! �'i ' f 14` I.Jv ' or Jju 9vFESSiON�♦ ` t R1 1 N \ �•1 r . �i 1 e: i 2 2�t31 2• 1y3160 - i � P _ . 7/ Y /bL y 3(o31Ll —. - — — 14o �b t 3r 03 f O 032254-1 4 i � 44 _ t _ 3u 3✓0 +�` 617 i 2/ 9 /tet R4�ttr5 1(3 µ/c � ce,Gt, s Jest Deck f"s Y M• ' 'fk�/° Po&4 c 2` < d K' o` r6 e U V R `IS /�rcdi• 13. 13( "< lr��o�1/'' 2^. 4` lG�o� 2Y< /2'' d 3+'y�<t'f"LUL J _ 7V& �� ch 2 l 1 9- 13 3h6l. t ►,MPJ � /G' /oqr s j 0 � F'loa•. � ptywo�� � ?A I F/oor ,FoCsE 2 IC TJ r W Cohc - 03zas4-9 �o Wei, PYeV pA6'FES SIO"A —� X-T61bc1 f 24 rdt S/a 6 I ' //Z yo l I I I I . I G-4" 0 1/4 TOP - DECK A5 PER OWNER 5PEC m sa-s` s'4^ In 2 RAILING96"FROM - ROOFTOP q. i ON. ci, 5',2" 7.7'READ 5 'I I I'TREADS p.� ©©© -� - R15ER5 'I ISI rREAoS I ' co RACING SY5PER PS PER 8'-9 /2" �. 5-4" OWNER I5pec, I .j. - -- 4-4 I co a I 5'-51/2" -j 5'-31/2" 16'4' — -- w DECK PLAN ROOF TOP RAILING PLAN g COOKE RESIDENCE 1 /4" = P 011 COOKE RESIDENCE 1 /4" = P-0" [� LL w i Q�. P-4 't4tlf NEgly W Q t n I � I © 4"X4" P05T BOLTEP' TO BOX BEAM �, f EXISTING.ROOF REFIN15H/PATCH AS iI REQUIRED . - t/2" CARRIAGE I I • BOLT5.DOLTED THROUGH BOX t - _ • - BEAM EX15TING BOX a n BEAM/2"X 1 O" JOIST 2-2xe•-GIRDER DETAIL OF 4X4 CJ7, I WLTLOTHROL1Gry +a^-a• Pbsr CONNECTION TO BOX BEAM Im 2x7 0* LEDGER I I I II II i I I I I � I ;. c I - 2xg•ccn �i_:I,1�_.��-L��_ I,l1L il_ _ �� f I 6 , I i TX I D'LEDGER — - — 2 E ,f'�� IT '. el M ON, 30" RAILING _ 2xe"Gen — �i�IT. m ! �e�.6 I G•o,C. rt II RAILING MIEGfdT TO. �.,j CODE A B LL PRS LOCATETE D EVERY 4" 2"kr�° c A - - 5 I/4 TOP DECK ', F.J. PC"O.Cy• ' I � - — y 2al OLEDGER _- - W I X CIA —. I I -10 � I 6f7L'I•ED TO OVI'DE MDQ 10 PROVtPe'RT7 USP \ HQUSE I12" USP CONNECTOR 2-2"XS" CCA CARRIAGE CONNECTOR, GIRDER-6QLTEp 2-2xd°61RDER 60LT5 16"O.C. 4"X4" CCA POST THROUGH 4"-4" G 1 , 4��ro5TRowon 2 � u2• POST E U nP PAU EX15TING FOUNDATION PROVIP , 6-h' DECK C>G GRADE 8.. S,ONOTUBE I I —_ 25.5' BIGFOOT (� C, C . fUNG► T1 ? ' AN � � DCK 5E�CTIOI UOI h' IET � 1 141 � COOKE KV51DENCE it 11-011 - • Do - UWIMD LAD PATH C NNtC - W , rIE FOLLo Wit '' .�'APPR09EO USP"KETAL CONNECTORS FOR PROPER,WINI) RESISTANT CONSTRI1C71lN : Fp' MA TION ED iN ON INSTROC MO TIMI ��1�3 � # IkJ�. � � , . 1�"f1'f . ` NAEP INSYAILATI TIONS' Tq kChIlE4E MAXIMUM UPUFT.L;OAD CAPAOfTY': . ,•,DVBMMWM - v Ow mwMUM JiOST al mel"ADER: .� POATCOLUMN �' CORdETE DECK/PORCH RAILING, ' STAIR RAILING FIQ!S �Lf !R("Fl�ClF$eoNf CTkNI � ' ) I - '. Usem zYttlhkraaV.Sc TteW�nsu Wvs MINIMUM HANORMLS T-11-I7 ' OmOE " Posy GIRDER/HEADER I � BALUSTERS wwbec Ja POST/COLUMN CONtlRETEF OPEN BALUSTER ATTAWTO WALL - •,� Ir�1 ' � �q HANDRAILGDIVNECTION . .rr,: 771! y ALL NwDWILSSHAU.SECONTINUOUS THE FUunEWN ppST-TO-DECK;CONNECTION L�J� . OFTNESTNR8. NANbGDPPORTIONOFALLHM - DFINKS IJ ? r' 8HML NOTGELM THAN 1.19"NOR MORE'RMN r IN 6T, A CROSSS now DIMENSION,ORTHESHARESHATL USF MIN,17114'DLA MV.BOLTSWRHWABHERBANDNUI9 �7II " PRDVIDEAN EDUNASENr OwhPINO BURFACE GIRDER/HEADER LOPOST/COWMN� CONNECTION e 'TOPNECROFSIDNOAND NODS UNDSYl1R6ED O1 •-,° ' GIwTFwIIEMER )rs pA ,�y - ©1WNLECRGY /�DR.wt�REMWEO) 'i( Z STAIR TREAD TUSEAWftAj8 POSTDOLUMN .. '� MRADEXRIM BOARD - 'FRL AS PER'MANUFACTUIW INSTRUCTIONS Fwoiz.JOISTSSTRINGER SLOGMNGPOR .101ST HANGER SOVSUSPNUMW CATION wuJaIfT/WDISTURBED / POOR' SOIL STRINGER TO DECK/PORCH CONNECTION ULYA-lPtA ENDPCIRIM gz at JAPPLTTOVAGMIMmm. DP, LIFDGER CONNECTION WVEL LEMANDOOMRACfBYISAD LkyKASTS50WOMODWACTEDGMAL NIBEw10fIfyN1UBE FhIAS PER MANUFACIUNIB'INSTRUCTIONS ;E m WOOD MST V WOOD MIST MIST BLOOM"ll GONC.PIER EQOTING OIROERRIEADm1 " 'BIOFODT SYSTEMS FOOTING FORM MACOORWw'.E MITI SECTION 101.11 OFNYA.FW4PEMIK CODE THIS OENON _ WTTINTSNfQFTFEiTEIN W000.1018T OIRDERNEAOFA WOODgR0F/{ SO' .APS SSp O1TLI THE IODE IN OUIVM UTYANCOOEANDDREFFPFEE OFTHAT J, 71�bNxIONOFCODECIFOgC€MpN'#ANDAbMWRIMIRONSMINW7 IBPRODUCT Lt.. ACCSPFABLE FORUSENN.G&rABm UPONICSOEV TN1NIfRVICERwom p PLUSH JOISTS WI�I�JjEAQERIGIRDER 6PrUF3ANDSUDIECT TO TrE DdYbITGNS THEREIN, 3 ALL HOISTS CONNECTED TO A RUSH HEAOERTT EESUPPORTEDWITH SPLIOEO HEAOERIGMtDERypPLIGI;IZ,IOt T$SmHHEApEMOI�R �4af xEM ye +L THE PROPER MAL DONNECFtlp. _JQ1S7t�0YEL�,,,, . PRovmEUGmONaeDTyAeDl aoIBTBTU,TARESPICEOAND 1�. BOE rV��•r IF ABLE,SET FNJOISTBARTOX tN'HNOHM TIIAIT LVL HEADERS USEWRH RT10TVDCWNANCHM TOALL 116HwNKAOE. IWto DECK 6 PORCH NOTES: A 4UPNwawwnobaWAwiVmNxWbMX ACO wruncMtlYwbr. — NAICINGSGHEDULE o ��. AAAMN;wNIry..wawNwnbbpMnUW'a NOIISSS�b91. JOINT ON DSPACING TIV. 71.OhtlwbMdjSWbM.CdWaNNlRldbwohP9NaMRWEAMNM ndnuM. JdBTTG ,— A-WOOMMON PER MIST CLIMATIC &81 GEOGRAPHIC'DESI N CRI R'lA _ atl?aPwA cnmFR z-eacoACAon so oroa+P�.b.m•mzum�m,rra..rMnz,wealaBww..Hmw. / o 9).Pwbwppallgypn NWbwhaq q•tri17'A1�NAAmo•bburnY SNOW SPIED OESKMIVWND D ITIF7ING LNEI 1E1M1RE OEGY OPiNN1 ONOEILLAYNBNT ROW _ . Uw•mbMun 4T�r'1'bp rAryMbdlwM w�b�Nd nl4 FmIbS�Sh�F LOAD GlE00NY DEPTH 7D/F. REO�RFD HAZARDS _� E.IO COMM EACH � MAM1 S•IawpFE•. --L' WI�W 1 1A1E NM l0 y.pdplmHlwFbMCMMNPoe.aIS UNL 170 I��B SEVERE SFT. SATE OD TO 11 NONE RELOR'TORSIATE S-1BSODMMON ACE SA AmINwAAW101ANiArhSgdbl0FSM140pFb}wrwMBNM UMIMgr. 3-IW COMMON JO�ISI' NAL (�.. lldrFlb MANMNOb MiAdTO WA VYSA ENMWAwWnwtl mw D M1 wc. _ T' TO 3-SE COMMON PER M Jq8f M SLCwa�b PIMFAMb�W7wimT ww�P�W. �TOJmBT T ­ 2-INCOMMON JPER EMD rI.NINMbbbwpnitl YAM lwgSuwfw lllM JoWIW Nw Ww :W ,qMT 2-1MCMN FO�PT TOES NAL ix r`J 7,L i'T J N � y U. U oZf � Q - - Q O O O M FFII _ - -_ LJ \�au0 �rw w� q A��u I I I I O 1111 j II II I I I I ■ „ I O - - - ------- - - - - - - - - - - - - - - - - - - - - - - - L - - - - - -1 -1 L�L Cn - - - - - - - - - - - - - - - - - - - - Z - - - - - - - - -- - - - - - - - - - - - - -L - - - - -1: LEFT SIDE ELE\/ATION ZO U FRONT ELE\/AATION 1/4" I,_O. 1/4" 1'_0" H.1 G ■ w � � T- F ■ _ ® DRAWN BY: ACD CHECKER BY: DAC DATE: 7�P6-06 REV No. DATE: Iii ail iii iii ii Iii til 1 �i ail lei it I ', �� I 1-4ii LL LJ -P, ■ LLJJ- - - - - - - - L I - - - - - - - 1 JJ - J - - - - Z � - - - - - REAR ELEVATION RIGHT SIDE ELE\/ATION 1/4" ° 11- 0 " JOB NUMBER 1/4" = 11-011 1052571 z SHEET NUMBER 0 F= w OF COPYRIGHT AHELR00 & CHERVENY ARCHITECTS 2005 N � m —EXISTING WOOD d 28'-0" PORCH A Z m 7 yp O C y�. 0 7'-8" 3'-8" 5'-4" 3'-8" '1'-8" I� > PORCH d w : :' i` `•' ", •, r+ XISTING WINDOW �L EXISTING DOOR GL EXISTING WINDOW o6 V Ca E ■ 8" b" �� 8" 14'-6" 8' 11' EXISTING HDR d p EXISTING HDR O 3 z 3 fy 4" 15'-4" 4' o p o EXISTING 2x 8 FJ 'V m z z EXIST& 16^oc m m BEDRM #2 8" T_3 w T._3.. 8 ':. W w – o n u a o 1 —EXISTING (2) 2x 8 F LOW WOOD GIRDER w n < O d v _ , lie III L _ 4" b'_8" 4"L11 -4.. 3'_0' 4" 5' 4" 4.. N �` X15TING COLUMN ON ■ Q oo EXIST& I EX15T'G FOOTING 3o O z —EXISTING MASONRY ` N N CRAWL3'-4" HIGH x o o IN = o FIREPLACE ; SPACE KNEE WALL ry p n ASEMENT ACCESS 3 EXISTG – – w BATH O ---(5) I-5/4"x 1-1/2" �. x EXIST& n - FLUSH L.V.L. W/ 'A BA5EME T W = WIGL o EACH END (TYP) ot m � = V N q0 i!1 r z t1c- 4" 4'-0" 4'W - 1_8 4" lz x 8" I'-b" 2'-2" 8" 5'-O" 1'-4" 8" I .' o EXISTS o J o Q BEDRM #5 b w O ■ Q� r 3 z = 1 r zIs) EXIST& 00 O x KITGHE O O ry cJ� ) n m EXISTING (2) 2x 10 N w - LOW WOOD GIRDER m w PAN O 12'-0" 8" 2' 4" 5'-O" 1 T'-4" e" EX15TI G WINDOW o 2) -3/4"x 9-I/2" O a EXISTING HDR – L J 51-8" 8'-4' 4" 3'- 4" 2'-0" 4" FLUSH L.V.L. WITH o A 4 2 1FLITCH ry o EXISTEACH END (TYPICAL) Q ING 2x 8 FJ 16"Oc 1 ry o i EXISTS, I—NWOOD DECK O ■ CRAWL I RAWL SPACE a SPACE L 1 ACCESS PANEL (SEE DECK PLANS) 2 12 RR W/ 2x 8 15TERED ! 1 0 w,OG (1e)FT) \�✓J XISTING GONG. PIER o v 8 -4 7-4 8" ON 24"x 24"x 12" D.P. Z—Nrh WOOD DECK ABOVE P.G. FOOTING (TYPICAL) o EXISTG 2 3 (SEE DECK PLANS) r v BRKFST Z � z --EXISTING 12"x 6" p kD N ' O SILL VENTS w w o ■ EXISTING HDR v rV/,J 12'-0' I6'-0" EX1571N6 5L, GL. DR. 28'-0" 2x10 RIDGE BM F F — — _ —SINE OF NEW A /—NEA1 WOOD DECK ABOVE WOOD DECK ABOVE 2x 8 RR- 16" O.G. 1 (SEE DECK PLANS) //���N EW 12" DIA. I—NEA WOOD DECK ONOTUBE PIERS 12 12 — — — � +/- 12 F 7+/- 12 (SEE DECK PLANS) O O (2) 1-5/4"x 9-1/2" 2x b COLLAR TIES L - - - - - - - - - - - - - J FLUSH L.v.L. w1rH = FOUND?�TI ON FL/�N TORCH DOWN ROOF (I) 2x 10 FLITCH 32" O.G. UNPINI5HELO ATTIC DRAWN BY: eco ■ SYSTEM E (4) 2x 4 P05T FIRST FLOOR FLAN EACH END (TYPICAL) 2x 8 GJ- Ib" O.G. I/4" • I'-O" 2x 12 GJ w/ 2x PJ CHECKED BY: ORC 515TERED- 16" O.G. 1/4" = I'-O" EXISTING LIVING AREA: 106'1 50. FT. DATE: 1.2x-05 METAL DRIP EDGE - ALL DIMENSION5 ARE APPROXIMATE REV No. DATE: (R-50) BATT /2^ GYP. BD. ON q" 1 BATT 2x 4 STUD WALL 16" OO INSULATION WALLS t CEILING INSULATION EXIST. 1/2" SHEET ROCK - O.H. 5-1/2" (R-IS) BATT5 o EX15TG EXISTG (3) -3/4"x 1-1/2" I/2" PLYWOOD BRKFST KITCHEN WIGL EXI5T& FLUSH L.V.L. W/ TYVEK OR EQUAL i v1NYL SIVINv 2x 8 FJ- 6" O.G. /4" PLYWOOD FAMILY (4) 2x 4 P05T NEW DECK 2) 2x 10 LOW SUBFLOOR ROOM EACH END (TYP) ■ (SEE DECK PLANS) WOOD GIRDER 2x 8 FJ- 16" O.G. BM PKT99 22 99 8" G.M.U. WALL5 ON CRAWL fl N 2" SCREED 2) .2x 8 LOW 6"x 8" P.G. FOOTING 5PACE GOAT EXIST& WOOD GIRDER BA5EMENT " DIA. LALLY dOE NUMBER o L _ J L J COLUMN ON ? ® � r Fn 24"x 24"x 12" D.P. EXI5TING GONG. PIER P.G. FOOTING (TYP) ON 24"x 24N 12" D.P. N SHEET NUMBER P.G. FOOTING (TYPICAL) 5EGTION j"��"�i 4" P.C. SLAB _ COPYRIGHT AXELROD k CHERVENY ARCHITECTS 2005 Ej ti M EXIST6 GRAAL SPACE o EXISTING Lj � Mo OU WINDOWS a w s O' 1 Cr `J ■ 10 ACO NAILER. LAGG 80LT -0'2'-0' q'-Q" F- oil U v od CIOIN G B 17— QO INTO EXISTING BEAM 3/8" U Q LAG& B0L75 5TA66ARED I6" OG. ' NqN C) Q 4. 15 (2) 2x 10 AGO LOW WOOD GIRDER. BOLTQ G ( ) 7 INTO 4x 4 P05T WITH I O EXI 1z (2) 3/8" STAINLESS STEEL LAGG BOLTS. I GRAAL 5PACE x a EXISTING 12" DIA. SONOTUEJE PIER 2x 10 AGa DECK BMS DOOR TO 36" BELOW GRADE. O I 161Poc (12l PF e qw p z4 4x 4 AGO DECK POSTS I I I f I T I M 0 ■ ANCHORED IN 50N0TUBE a " EXISTING 5L. GL. DR. PIER. (SEE DETAIL) I I I 9 2x 10 AGO NAILER. LAGG BOLT O - 113 INTO EXISTING BOX BEAM I/2" s I auna�cnw"xxroxmvs. DOWN-WOOD 1p o 2x O AGO DECK U- STAINLESS LA&& DOLT5 m EMS- 16" Q.G. LU '? I 5TA66ARED 16" OG. 36" HIGH WOOD RAILING WITH — — INE OF WOOD (HANDRAIL— mb -PTYPICAL) €b�NP. 0 4x 4 POST GAPS 2-0 2 -O 2-O 6 4'-b"— N 6' 0" d 9 I o DECK ABOVE GAIRAGE FRAME 1LL� _ - - Im - ■ o WOOD 5TEP5 T —_ �IIo ry IS:) GRADE ABOVE _ _ �I a I O C - - - � 2) 2x10AGO L0N !nI 0 O y _ WOOD GIRDER. BOLTNZ � I I 21' W � _ INTO 4x 4 P05T WITH ^ �dJ o (2) 3/8" STAINLESS a 16'-0 I—I u STEEL LAGG BOLTS. I I I ^ V o 2" DIA. SONOTUBE PIER - ' ' " 0 TO 36" BELOW GRADE.4' 0" 2' O" 5'- PR0P05ED WOOD o I I A—N O x 4 AGa DECK POSTS I FRAME \FRAME DECK FOUNDATION PLAN A ANCHORED IN 50N0TUBE DGK PLAN1/4" = I' PIER. (SEE DETAIL) ■ I Z � � II�I� I� NN�-.I--II C/7 \III-IN" I O ■ ■ ADDITIONAL GENERAL NOTES: EXISTING I STORY GALAVANIZED FRAMING GALVANIZED JOIST HANGAR BEFORE BEGINNINS WORK AT THE SITE, WHERE POSSIBLE, AND i FRAME DWELLING STRAP. PROVIDE ICE d PROVIDE ICE E WEATHER THROUGHOUT THE COURSE OF THE WORK, INSPECT AND VERIFY WEATHER SHIELD BEHIND = SHEILD BEHIND HANGAR WHERE THE LOCATION AND CONDITION OF EVERY ITEM AFFECTED BY STRAP WHERE STRAFING THE WORK UNDER THIS CONTRACT AND REPORT DISCREPANCIES I I F = HANGAR MAKES CONTACT WITH TO THE ARCHITECT BEFORE DOING WORK RELATED TO THAT BEING MAKES CONTACT WITH A AGO WOOD JOISTS. NSPECTED, WOOD. ALT: 5TAINLE55 STEEL HANGAR. BEFORE BEGINNING WORK AT THE SITE, INSPECT THE ALT: 5TAINLE55 STEEL EXISTING BUILDING AND DETERMINE THE EXTENT OF EXISTING FINISHES, SPECIALTIES, CASEWORK, EQUIPMENT, AND OTHER I I_I o I I I� STRAPPING ITEMS WHICH MUST BE REMOVED AND REINSTALLED IN ORDER TO PERFORM THE WORK UNDER TH15 CONTRACT. 2X IO DECK BMS- I6° O.G, _- THE ARGHITEGTURAL DRAWIN65 5H0W PRINCIPAL AREAS WHERE (2) 2X IO AGa LOW WI� ORK MUST BE AGC0MPL15HED UNDER THI5 CONTRACT. L INCIDENTAL WORK MAY ALSO BE NECESSARY IN AREAS ■ WOOD GIRDER. BOLT NOT SHOWN ON THE ARCHITECTURAL DRAWINGS DUE TO CHANSES INTO 4x 4 P05T WITH2x 10 ACO NAILER. AFFECTING EXISTING MECHANICAL, ELECTRJGAL, PLUMBING, (2) 3/8" 5TAINLE55 LASE BOLT INTO OR OTHER SYSTEMS. SUCH INCIDENTAL WORK IS AL50 A PART , OF THIS CONTRACT. INSPECT THOSE AREAS, AND ASCERTAIN I : STEEL LAG G BOLTS. EXISTING BOX BEAM WORK NEEDED, AND DO THAT WORK IN ACCORD WITH THE CONTRACT DRAWN BYACD 1/2" 57AINLE55 LAGG REQUIREMENTS, AT NO ADDITIONAL COST. BAC 4x 4 ACO POST ANCHORS BOLTS 5TAS6ARED Ib" OC. CHECKED BY:I I INTO 5ON0TUBE PIER, OATS: 1-2ORO 05 PROVIDE 5TAINLE55 LAGG I �N I REV No. DATE: BOLTS AT BOTTOM. LEAVE BOLT EXP05ED 3". - . I-I 11- I I -I I1I 11=111= 1 0 _ _ - 2" DIA. SDNOTUBE — ■ PIER WI/ 4" STONE -I I = = I J BASE TO 36" BELOW IN GRADE. I L —III=III—III—III—III= I ' I I—III—III—III—IIIT- SROAD : ION PLOT PLAN JOB NUMBER N.T.S. 0 Z) 1 2571 SHEET NUMBER a U COPYRIGHT AXELROD h CHERVENY ARCHITECTS 2005 o OF