Loading...
HomeMy WebLinkAbout31710-ZFORM NO. 4 TOWN OF SOUTHOLD BUILDING DEPARTMENT Office of the Building Inspector Town Hall Southold, N.Y. CERTIFICATE OF OCCUPANCY No: Z-31582 THIS CERTIFIES that the building PORCH ADDITION Date: 05/26/06 Location of Property: 1755 SIGSBEE RD LAUREL (HOUSE NO.) (STREET) (HAMLET) County Tax Map No. 473889 Section 144 Block 2 Lot 13 Subdivision Filed Map No. Lot NO. conforms substantially to the Application for Building Permit heretofore filed in this office dated JANUARY 3, 2006 pursuant to which Building Permit No. 31710-Z dated JANUARY 5, 2006 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is PORCH ADDITION TO AN EXISTING SINGLE FAMILY DWELLING AS APPLIED FOR & AS PER CONDITIONS OF ZBA #5785 DATED 12/1/05 DATED 1/5/06. The certificate is issued to BARBARA A CONDON (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL N/A ELECTRICAL CERTIFICATE NO. N/A PLUMBERS CERTIFICATION DATED Rev. 1/81 N/A Authorized Signature 1 �- I<i `-L Form No. 6 -- TOWN OF SOUTHOLD BUILDING DEPARTMENT TORN HALL 765-1802 MAY Z 5 APPLICATION FOR CERTIFICATE OF OCCI P This application must be filled in by typewriter or ink and submitted to the Buildira i en ✓wr a following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings, property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage -disposal (S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead. 5. Commercial building, industrial building, multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings (prior to April 9, 1957) non -conforming uses, or buildings and "pre-existing" land uses: 1. Accurate survey of property showing all property lines, streets, building and unusual natural or topographic features. 2. A properly completed application and a consent to inspect signed by the applicant. If a Certificate of Occupancy is denied, the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy - New dwelling $25.00, Additions to dwelling $25.00, Alterations to dwelling $25.00, Swimming pool $25.00, Accessory building $25.00, Additions to accessory building $25.00, Businesses $50.00. 2. Certificate of Occupancy on Pre-existing Building - $100.00 3. Copy of Certificate of Occupancy - $25.00 4. Updated Certificate of Occupancy - $50.00 5. Temporary Certificate of Occupancy - Residential $15.00, Commercial $15.00 New Construction: Old or Pre-existing Building: Date. 4 -2S -Ob (check one) Location of Property: 1:755 !!5714,. zaa� QQ4-V M AT -% rr OGIG House No. Street /J Hamlet Owner or Owners of Property: T� rf o S. Q AjZCi/i C.O�L1�o47 Suffolk County Tax Map No 1000, Section 144 Block Z Lot 12-9 13 Subdivision /1/Jk(T Se MWA / 6W- ]05T• Filed Map. 'cob Lot: eggQ'70 Permit No. _--� I %/ O Date of Permit. Applicant: Somo (fo&a� Health Dept. Approval: AM Underwriters Approval: /VA Planning Board Approval: A.)A Request for: Temporary Certificate Final Certificate: (check one) Fee Submitted: $ ZS �•-)02V co -f 315 ga FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 31710 Z Permission is hereby granted to: BARBARA A CONDON 1755 SIGSBEE ROAD MATTITUCK,NY 11952 for : Date JANUARY 5, 2006 CONSTRUCTION OF A PORCH ADDITION TO AN EXISTING SINGLE FAMILY DWELLING PER ZBA DECISION #5785 AS APPLIED FOR at premises located at 1755 SIGSBEE RD LAUREL County Tax Map No. 473889 Section 144 Block 0002 Lot No. 013 pursuant to application dated JANUARY 3, 2006 and approved by the Building Inspector to expire on JULY 5, 2007. Fee $ 150.00 Authorized Signature ORIGINAL Rev. 5/8/02 31-2i6 -2'--7 APPEALS BOARD MEMBERS Ruth D. Oliva, Chairwoman Gerard P. Goehringer Vincent Orlando James Dinizio, Jr. Michael A. Simon IAN 3 http://southoldtown.northfork.net BOARD OF APPEALS TOWN OF SOUTHOLD Southold Town Hall 53095 Main Road • P.O. Box 1179 Southold, NY 11971-0959 Office Location: Town Annex /First Floor, North Fork Bank 54375 Main Road (at Youngs Avenue) Southold, NY 11971 Tel. (631) 765-1809 • Fax (631) 765.9064 I FINDINGS, DELIBERATIONS AND DETERMINATION MEETING OF DECEMBER 1, 2005 ZB File No. 5785 — John and Barbara Condon Property Location: 1755 Sigsbee Road, Mattituck CTM 144-2-12 and 13 as one lot SEQRA DETERMINATION: The Zoning Board of Appeals has visited the property under consideration in this application and determines that this review falls under the Type II category of the State's List of Actions, without an adverse effect on the environment if the project is implemented as planned. PROPERTY FACTS/DESCRIPTION: The applicant's 14,000 square foot parcel has 100 feet along the north side of Sigsbee Road in Mattituck, and is improved with an existing two-story residence with deck, shown on the site plan prepared by Condon Engineering, P.C. (Sheet S-1), based on the May 11, 1981 survey prepared by Baldwin and Cornelius, P.C. BASIS OF APPLICATION: Building Department's August 31, 2005 Notice of Disapproval, citing Section 100- 244 in its denial of an application for a building permit to construct a proposed addition to the existing single- family dwelling. The reason stated by the Building Inspector in the denial is the addition will be 30.9 feet instead of 35 feet from the front yard lot line. FINDINGS OF FACT The Zoning Board of Appeals held a public hearing on this application on November 17, 2005 at which time written and oral evidence were presented. Based upon all testimony, documentation, personal inspection of the property, and other evidence, the Zoning Board finds the following facts to be true and relevant: AREA VARIANCE RELIEF REQUESTED: The applicants wish to construct a new, roofed -over open porch 11'5" by 6'4" in size, replacing the previous steps and landing. The setback will be 327' from the lower step area at its closest point, and 33'4" to the porch. The height of the roof of the open porch will be 12'4". REASONS FOR BOARD ACTION: On the basis of testimony presented, materials submitted and personal inspections, the Board makes the following findings: 1. Grant of the variance will not produce an undesirable change in the character of the neighborhood or a detriment to nearby properties. The open porch addition is minor, with an area less than 75 square feet and will serve to soften the two-story wall of the home 41 feet from the front lot line facing Sigsbee Road 2. The benefit sought by the applicant cannot be achieved by some method, feasible for the applicant to pursue, other than an area variance. The opposite side of the home in the rear has a large deck and walk constructed to lessen the difficult walk on the side of the dwelling, due to the steep contour in the topography of the land. P5hge 2 — December 1, 2005 ZB File Ref. 5785 — John and Barbara Condon CTM 144-2-12 and 13 as one lot 3. The variance granted herein is not substantial and represents only a minor reduction related to a new entry area, replacing the former step areas. The new roofed -over entry would be exempt from the code setback requirements if it were 30 square feet (6'x 5') instead of 72 square feet. 4. The difficulty has been self-created. The applicants could build a functional front entry of 30 square feet that would not require a variance. 5. No evidence has been submitted to suggest that a variance in this residential community will have an adverse impact on the physical or environmental conditions in the neighborhood. 6. Grant of the requested relief is the minimum action necessary and adequate to enable the applicant to enjoy the benefit of a small entry addition, while preserving and protecting the character of the neighborhood and the health, safety and welfare of the community. RESOLUTION OF THE BOARD: In considering all of the above factors and applying the balancing test under New York Town Law 267-B, motion was offered by Member Dinizio, seconded by Member Goehringer, and duly carried, to GRANT the variance as applied for, as shown on the site plan prepared by Condon Engineering, P.C. (Sheet S-1) with a ZBA date stamp of October 11, 2005, SUBJECT TO THE FOLLOWING CONDITION: That the roofed -over open porch never be enclosed. This action does not authorize or condone any current or future use, setback or other feature of the subject property that may violate the Zoning Code, other than such uses, setbacks and other features as are expressly addressed in this action. Vote of the Board: Ayes: Members Oliva (Chairwoman), Orlando, Goehringer, Dinizio, and Simon. This Resolution was duly adopted (5-0). Ruth D. Oliva, Chairwoman 12/30' /05 Approved for Filing 3171° Z, TOWN OF SOUTHOLD BUILDING DEPT. 765.1802 INSPECTION [ ] FOUNDATION IST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATIO [ ] FRAMING/ STRAPPING [ FINAL [ ] FIREPLACE A CHIMNEY [ ] FIRE SAFETY INSPECTION REMARKS: DATE S ;L�-U� INSPECTOR W. FIELD IN. PECTION REPORT DATE COMMENTS Ft�� FOUNDATION (1ST) ----------------------------------- y xk FOUNDATION (2ND) z ROUGH FRAMING & PLUMBING y JI1 Cr, INSULATION PER N. Y. STATE ENERGY CODE RI y FINAL 77 ADDITIONAL COMMENTS (i Z 2,0 z m. -t �k 1 L � y O z rAx Z� y x d m b y Z3 TOWN OF SOUTHOLD PROPERTY RECORD CARD All OWNER STREET J75 VILLAGE DIST. am ro SUB. LOT g'.. FORMER OWNER//1� .lA n f,00 N E ACR. 3 Y S W TYPE OF BUILDING ES. r SEAS. VL. FARM COMM. CB. MISC. 'Mkt. Value ... LAND IMP. TOTAL DATE REMARKS "'� ✓ Q 6 Odfd' D iy �.Cc[ ���.Sdd /7a/ -risers fe �orioon /0 .Y{<7 ✓ 00 l /80 /7D �' Sjz./�� r P /06 F5 �:,;.,r,. �, 6�✓ �.�. �5��� Il?S'p ,. 00 99 017�IA�Zll © CDU �� G % (� ce o 3 - C orl s. k 94 2 -6 on ua - 5 ru A69"1-030,ooc� Tao .?/o -o � 2500 / .2Coa i .iy�y/�3 � o2Cn �%.?• X020 -CD/7a�.� .^ j � t �a c3 . IL6DION CyCO�T N Co7/2dDY1- NL ?Cc 550© rt %-% �4- - FARM Acre Value Per Acre Value / Tillable 1 Tillable 2 Tillable 3 Woodland Swampland FRONTAGE ON WATER 3rushland FRONTAGE ON ROAD -louse Plot DEPTH �+C BULKHEAD Total DOCK „Vf TOWN OF SOUTHOLD PROPERTY RECORD CARD OWNER STREET VILLAGE DIST. SUB. LOT ACR. REMARKS TYPE OF BLD. PROP. CLASS LAND IMP. TOTAL DATE FRONTAGE ON WATER TILLABLE FRONTAGE ON ROAD WOODLAND DEPTH MEADOWLAND BULKHEAD HOUSE/LOT TOTAL TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL SOUTHOLD, NY 11971 TEL: (631) 765-1802 FAX: (631) 765-9502 www. northfork.net/Southold/ Examined s 2&_ Approved Disapproved a/c PERMIT NO. 311(0 & BUILDING PERMIT APPLICATION CHECKLIST Do you have or need the following, before applying? Board of Health 4 sets of Building Plans Planning Board approval Check Septic Form N.Y.S.D.E.C. Trustees Contact: Mail to: .. Phone: ` APnICATION FOR BUILDING PERMIT \ Date Ss— ZS 20 SJ \\ INSTRUCTIONS a. This applic8tf MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 3 sets of plans, accurate plot plan to scale. Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application, the Building Inspector will issue a Budding Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e. No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim, the Building Inspector may authorize, in writing, the extension of the permit for an addition six months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County, New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances, building code, housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. of applicant or name, if a corporation) / ), S,a' StSsQFE (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder Name of owner of premises (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. Plumbers License No. Electricians License 1` Other Trade's License 1. Location of land on which proposed work will be done: /7s e tC.sgey_�!dpyy ITr.NlG House Number Street Hamlet County Tax Map No. 1000 Section /'fes Block Z Lot 12- R 13 (Name) IAO `v Filed Map 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy_ b. Intended use and occupancy �rrc�r n cu« 3. Nature of work (check which applicable): New Building Addition_ _/ Alteration Repair Removal Demolition Other Work (Description) 4. Estimated Cost �000 Pee (To be paid on filing this application) 5. If dwelling, number of dwelling units__/ _Number of dwelling units on each floor / If garage, number of cars b_ if business, a ommercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing strachnw, if any: Front Rear Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front Rear Depth tiei$iif Number of Stories 8. Dimensions of entire new construction: Front � "Rear // S ~ Depot �4 Height 12-'-4 ° Number of Stories 4. Size of lot: Front /Gl7 / Rear /� Depth 10. Date of Purchase Name of Former Owner 11. Zone or use district in which premises are situated R-9 -- 12. __._.12. Does proposed construction violate any zoning law, ordinance or regulation? YES_ NOV-- 13. Will lot bete- graded? YES_ NO �C Will excess fill be removed from premises? YES_ NO- -115 +t - SsS� See r 14. Names of Owner of ses g R 6¢�6Address Phone No. — Name of Architect Address Phone No Name of Contractor Address Phone No. 15 a.. Is this property within 100 feet of a tidal wetland or a freshwater wetland? 'AYES NO * IF YES, SOUTHOLD TOWN TRUSTEES & B.E.C. PERMITS MAY BE REQUIRED. b. is this property within 300 feet of a tidal wetland? * YES NO_Y_ * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale, with accwate foundation pian and distances to property lines. 17. If elevation at any point on property is at M feet or below, must provide topographical data on survey. STATE OF NEW YORK) SS: COMTY Ofk I joF{/J ( /1 0 /J hQn being duly sworn, deposes and says that (s)he is the applicant {Name of individual signing contract) above named, (S)He is the (Contractor. Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed thetewi& Sw rn to b ole me this 7day of 200 otary Public STEP FLASHING BETWEEN WALL AND ROOF WITH KICK OUTS AT ROOF EDGE CEDAR RAILING AND BALLASTERS 4" SPACE BE TWEEN BALLASTERS MIN WEST ELEVATION NORTH ELEVATION TO SHINGLES ALLCOLUMNS AND BEAMS ARE TO BE CLAD IN 1 X CLEAR CEDAR AND FINISHED WITH CABOT CLEAR STAIN WALK ELEV EXISTING RESIDENCE 04 COLUMN FROM ABOVE COLUMN ROOF PLAN (2X4) COLUMN FROM ABOVE 0 :o (2LIDGIRDER B"O SONOTUBE FILLED FROM ABOVE AND 4x4 RAILING POSTS 12"m SONOTUBE FILLED WITH CONCRETE FOUNDATION & 1 ST FLOOR PLAN ROOF COLUMN AND RAILING POST BOLTING DETAIL Gmund Snow Lead Wind Speed Sasmic Weelhenng Fred Line Termite Decay Winter Design Ice Shield Floodld. I I Depth I Temp Cndarlaaymrenl I I t o R KU I 45 psf 120mph A Severe 36 in Moderate Slight to 11-F Nane LU to Meavy Moderate o I l S 2003800" E 100.00' N 2003800" W 100.00' SIGSBEE ROAD SCTM# 1000-144-2-12 &.13 Mattituck Park District # 801 Lot 69 & 70 SITE PLAN SCALE T=2P SURVEY INFORMATION TAKEN FROM MAP OF MATTITUCK PARK ESTATED DATED 1928 CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA GENERAL NOTES: General: 1 - Occupancy classification - Residential Group R-3 OCCUPANCY OR 2 - Type 5 - Wood framed construction to be utilized. USE IS UNLAWFUL 3 -Building height - 124", fire area - 66 s.f. WITHOUT CERTIFICATE OF OCCUPAN 4 - Design Criteria - NYS Residential Code R301.2.1.1 and utilized Cher methods and procedures stipulated in Chapter 2 Engineered Design and Chapter 3 Prescriptive Design in the American Forest and Pal Association Wood Frame construction Manual for One and Two Famolly Dwelling Units - High Wind Addition and ASCE 7, SCOPE OF WORK: Removal of existing wood stairs, APPROVED AS NOTED DATE 0P.# 3/710 -Installation of new stairs and roof as shown in plans. STRUCTURAL NOTES: NOTIFY BUILD D- ARTMENT AT 765-1802 B Ak. 40M FOR THE AiSpFr mi 1 -All framing is to be in accordance with the New York Slate Building Code anT� lI ,rWFCiFOLLY ' 'IM' III IJ -WlridXd Q�IRED FDF; POURED C'.NCRETE 2 -All concrete 3,500 psi after 28 days minimum. 2. ROUGH - FRA' lit i. PLUMBING 3. IN8ULATICN 3 - Footings are to be installed on undisturbed virgin soil. 4. FINAL - CONS!' J 111'rl MUST the bottoms of all footings are to be installed a minimum of 4' below grade unless iBQllcatwotherlvnse0r= CO. ALL CONSTFU"T"ION SHALL MEET THE 4 - All measurements are to be confirmed in the field. Discrepanoies are to be b lR@IbU (UhENTE OF THE CODES OF NEW attention of the englneeT prior to malerlal ordering and fabrication. YORK STATE. NOT RESPCNSIBLE FOR DESIGN OR lul N ERRORS. p1E OF Design Loads: CERTIFI�_ , ,ION OF 51 - B- GO "?- NAILING & CONNECTfONS ori 0 - Roof -Live Load -35.5 psf- REQUIRED. Based on ASCE-7 and Pg = 45 psf per Figure R301.2(5) `PFO - 84 - Dead Load -15 psf p�-----'' SSIo, �- ALL CONSTRUCTION SHALL Au{LF Exterior Deck - Live Load "40 cat Dead Load -15 s psWET THE REQUIREMENTS OF THE g_­,R—,P CODES OF NEW YORRa9TAkTLrepered by Condon Engineering, PC It is a Wolation of the - Wind Loads - 120 mph -ASCE-7 New York State Education Law, Article 145, Sai 7209, for any person unless acting under the direction of a licensed Professional MWFRS - Method 2 Engineer, Architect, or Land Surveyor, to eller any item in any way. If Component and Cladding - Details from an Item bearing the seal of an Engineer, Architect, or Lend Surveyor Is WFCM TABLE 3.8 altered, the altering Engineer, Architect, or Land Surveyor shall affix to the item hislher seal and the notation "Altered by" followed by Neither signature and the date at such alterations, and a specific description of the alters I�rTAIN STORM WATER RUNOFF OF THE TOWN CODE. Scale ," vo- Condon Engineering, P.C. Condon Residence 1755 Slgsbea Read Drawn by JJC 1755 Slgsbee Road Manitack, Nae Yerk Mattituck, New York 11952 Date e282005 (631)298-1986 Porch Addition I I I I I I I I LOT 70 LOT 69 I 01 I I t o I 0 v LU o I l I I I cV 0 EXISTING DECK 0 c N I U EXISTING 2 -STORY RESIDENCE s.e. I I I I Q M I m 29tI I I I Q m ENTRY U 9 hND Z W 0 m U � 829.83 � N 2003800" W 100.00' SIGSBEE ROAD SCTM# 1000-144-2-12 &.13 Mattituck Park District # 801 Lot 69 & 70 SITE PLAN SCALE T=2P SURVEY INFORMATION TAKEN FROM MAP OF MATTITUCK PARK ESTATED DATED 1928 CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA GENERAL NOTES: General: 1 - Occupancy classification - Residential Group R-3 OCCUPANCY OR 2 - Type 5 - Wood framed construction to be utilized. USE IS UNLAWFUL 3 -Building height - 124", fire area - 66 s.f. WITHOUT CERTIFICATE OF OCCUPAN 4 - Design Criteria - NYS Residential Code R301.2.1.1 and utilized Cher methods and procedures stipulated in Chapter 2 Engineered Design and Chapter 3 Prescriptive Design in the American Forest and Pal Association Wood Frame construction Manual for One and Two Famolly Dwelling Units - High Wind Addition and ASCE 7, SCOPE OF WORK: Removal of existing wood stairs, APPROVED AS NOTED DATE 0P.# 3/710 -Installation of new stairs and roof as shown in plans. STRUCTURAL NOTES: NOTIFY BUILD D- ARTMENT AT 765-1802 B Ak. 40M FOR THE AiSpFr mi 1 -All framing is to be in accordance with the New York Slate Building Code anT� lI ,rWFCiFOLLY ' 'IM' III IJ -WlridXd Q�IRED FDF; POURED C'.NCRETE 2 -All concrete 3,500 psi after 28 days minimum. 2. ROUGH - FRA' lit i. PLUMBING 3. IN8ULATICN 3 - Footings are to be installed on undisturbed virgin soil. 4. FINAL - CONS!' J 111'rl MUST the bottoms of all footings are to be installed a minimum of 4' below grade unless iBQllcatwotherlvnse0r= CO. ALL CONSTFU"T"ION SHALL MEET THE 4 - All measurements are to be confirmed in the field. Discrepanoies are to be b lR@IbU (UhENTE OF THE CODES OF NEW attention of the englneeT prior to malerlal ordering and fabrication. YORK STATE. NOT RESPCNSIBLE FOR DESIGN OR lul N ERRORS. p1E OF Design Loads: CERTIFI�_ , ,ION OF 51 - B- GO "?- NAILING & CONNECTfONS ori 0 - Roof -Live Load -35.5 psf- REQUIRED. Based on ASCE-7 and Pg = 45 psf per Figure R301.2(5) `PFO - 84 - Dead Load -15 psf p�-----'' SSIo, �- ALL CONSTRUCTION SHALL Au{LF Exterior Deck - Live Load "40 cat Dead Load -15 s psWET THE REQUIREMENTS OF THE g_­,R—,P CODES OF NEW YORRa9TAkTLrepered by Condon Engineering, PC It is a Wolation of the - Wind Loads - 120 mph -ASCE-7 New York State Education Law, Article 145, Sai 7209, for any person unless acting under the direction of a licensed Professional MWFRS - Method 2 Engineer, Architect, or Land Surveyor, to eller any item in any way. If Component and Cladding - Details from an Item bearing the seal of an Engineer, Architect, or Lend Surveyor Is WFCM TABLE 3.8 altered, the altering Engineer, Architect, or Land Surveyor shall affix to the item hislher seal and the notation "Altered by" followed by Neither signature and the date at such alterations, and a specific description of the alters I�rTAIN STORM WATER RUNOFF OF THE TOWN CODE. Scale ," vo- Condon Engineering, P.C. Condon Residence 1755 Slgsbea Read Drawn by JJC 1755 Slgsbee Road Manitack, Nae Yerk Mattituck, New York 11952 Date e282005 (631)298-1986 Porch Addition