Loading...
HomeMy WebLinkAbout29169-ZFORM NO. 4 TOWN OF SOUTHOLD BUILDING DEPARTMENT Office of the Building Inspector Town Hall Southold, N.Y. CERTIFICATE OF OCCUPANCY No: Z-31402 Date: 01/17/06 THIS CERTIFIES that the building ADDITION & ALTERATION Location of Property: 55135 MAIN RD SOUTHOLD (HOUSE NO.) (STREET) (HAMLET) County Tax Map No. 473889 Section 62 Block 1 Lot 11.1 Sutx~ivision Filed Map No. __ Lot No. -- conforms substantially to the Application for Building Permit heretofore filed in this office dated DECEMBER 26~ 2002 pursuant to which Building Permit No. 29169-Z dated FEBRUARY 28, 2003 was issued, and conforms to all of the requirements of the applicable provisions of the law. The Occupancy for which this certificate is issued is TWO STORY ADDITION & ALTERATIONS AN AN EXISTING BUILDING AS APPLIED FOR & AS PER CERTIFICATIONS OF MARTIN F. SENDLEWSKI, A.I.A. THe certificate is issued to SOUTHOLD FIRE DISTRICT ( OWNER ) of the aforesaid building. SIFFFOLK CO~ DEPAR~ OF ~TH AP~OVAL C10-04-0008 01/11/06 ELE~ICAL CERTIFICA~ NO. 94524C 08/21/05 PLUMBERS CERTIFICATION DA'£mu 11/07/05 PECONIC PLUMB. & HEATING Rev, 1/81 Form No. 6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TO~VN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY 2005 This application must be filled in by typewriter or mk and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings, property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. ,l. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead. 5. Conm~ercial building, industrial building, multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings (prior to April 9, 1957) non-conforming uses, or buildings and "pre-existing" land uses: 1. Accurate survey of property showing all property lines, streets, building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied, the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy - New dwelling $25.00, Additions to dwelling $25.00, Alterations to dwelling $25.00, Swimming pool $25.00, Accessory building $25.00, Additions to accessory building $25.00, Businesses $50.00. 2. Certificate of Occupancy on Pre-existing Building - $100.00 23. Copy of Certificate of Occupancy - $.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy - Residential $15.00, Commercial $15.00 Date. New Construction: ~- Old or Pre-existing Building: (check one) Location of Property: ~% ~'~ ~ tkt NI ~ ff__N3'4~ ~ House No. ?o ~07,. e'lOf!' Street Owuer or Owners of Property: ~0 C>-~ I~OL-~ ~lgC Sufiblk County Tax Map No 1000, Section ~ ~ Subdivision M/~ Permit No. '2 ~ ~ ~' q Health Dept. Approval: Planning Board Approval: Block Filed Map. Applicant: Underwriters Approval: Request for: Temporary Certificate Fee Submitted: $ bi / lk Final Certificate: Hamlet Lot t [o I Lot: /'J/~ (check one) ' - ~p~/i'~nt Signat~'re FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 29169 Z Date FEBRUARY 28, 2003 Permission is hereby granted to: FIRE DISTICT SOUTHOLD PO BOX 908 SOUTHOLD,NY 11971 for : CONSTRUCTION OF A TWO STORY ADDITION & ALTERATIONS TO AN EXISTING BUILDING AS APPLIED FOR & TO THE CONDITIONS OF THE NYS BUILDING CODE at premises located at 55135 MAIN RD County Tax Map No. 473889 Section 062 pursuant to application dated DECEMBER Building Inspector to expire on AUGUST SOUTHOLD Block 0001 Lot No. 011.001 26, 2002 and approved by the 28, 2004. Fee $ 0.00 ORIGINAL Rev. 5/8/02 Jul ~ ! O,~ Ol:~_4p southo~d ?ire ¢!istrict B31'?~55078 ~.3 Electrical InsFection Certificate leoue;I To: Southotcl Fire Deper~men! Street; 55135 Main Road Village: Southold Zip: 11971 Town: Southold $ectlon: Bl~k: Lot: Contractor: Mc Dowell Electric Corp, (L) Ltc, ~ 4484-E ~ ~tldeetl. J ~ DeL Glrigo ~ Attic ~ 2~ Flor [~ Outdoor ~ A~lt~n ~ Su.Jy 55 57 4 1720 3 Wa~e~Amp8 O~IAmp~ Oven Refl~e/Am~ Mic?oweves Sw/fchol Olehweeher Meter Amps t 800 Bidg, Permit: Other Equipment 1 800amp~ph disconnect ! 2 400 amp Isconnect switches / 1 225amp 3ph sub ianei/ ;2 100amp 3ph sub panel t 1 225amp ph automatic t~naler switch ? t 75w ~rator / 1 30am~ 3ph elevat~ dls~o~nem S exit liGht~ / 1 20amp 3ph air ~i~onnect Hugo $. President Town Hall, 53095 Main Road P.O. Box 1179 Southold, New York 11971-0959 Fax (631) 765-9502 Telephone (631) 765-1802 BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATION Building Permit No. (5~ q ~ ~ (~ ~- Owner: 50Gc'~DoI ~ ~[','"~ "~;$TI~,IC,T" (please print) Plumber: Pff. o,ao~ ~../,~Zo,~.~y,~,'~) (please print) lead. I certify that the solder used in the water supply system contains less than 2/10 of 1% " U (.f (l~um{~r~ Signature) ' Sworn to before me this Notary Public, Co mty MARTIN F. SENDLEWSKI, A.I.A. ARCHITECT -- PLANNER January 13, 2006 Town of Southold Building Dept. PO Box 1179 Southold, NY 11971 Attn: Mike Verity Re: Southold Fire District Dear Mr. Verity: Attached please find the final Suffolk County Health Dept. approval plan as required for receipt of final Certificates of Occupancy. Please call when they are ready. .-;;4;Martin ] [~fi-dlewski, AIA MFS/sst cc/Southold Fire District 215 ROANOKE AVENUE [] RIVERHEAD, N.Y 11901 · [631 ) 727-5352 · FAX (631 ] 727-5335 MARTIN F. SENDLEWSKI, A.I.A. ARCHITECT -- PLANNER August 23, 2005 Town of Southold Building Department PO Box 1179 Southold, NY 11971 Attn: Mike Verity Re: Southold Fire District Permit No. 29169 Z - Fireproofing Dear Mr. Verily: This correspondence is to certify that this office reviewed all steel fireproofing has been corrected where removed in the basement with rated Firefilm II or equal fireproofing (refer to attached). Cc~ Southold Fire District 215 ROANOKE AVENUE · RIVERHEAO, N.Y. 11901 · [631 ) 727-5352 · FAX [631 ) 727-5335 FIREFILM II DECORATIVE, INTUMESCENT FIREPROOFING FOR STRUCTURAL STEEL Clean Room Semiconductor, Pharmaceutical, and Sterile Industrial Facility Use A/D Fire Protection Systems presents you with the option of a truly thin-film intumescent fireproofing: A/D FIREFILM® II, for structural steel in clean room and sterile industrial facilities. A/I) FIREFILM® II is a Decorative, Thin-Film Intumescent Fireproofing for Structural Steel. During a fire it expands to form a meringue-like insulating ash which protects steel from fire for up to 3 hours. A/D FIREFILM II is the hardest, most resistant to impact and abrasion and has the highest compressive strength and adhesion/cohesion values on the market. A/D FIREFILM® II is Ideal for Applications: Where structural steel is to remain exposed Wi-.hin the clean air or secondary air stream With architectural statements With clearance issues Where multiple a~achments are needed A/D FIREFILM [lin a Class 1 clean room A/D FIREFILM® II is a Thin-Film, Water Based (0 VOC's), Non Off-Gassing Intumescent Fireproofing. In its applied state, it gives the appearance of a paint coating over structural steel. The decorative, protective A/D COLORCOAT® (or other approved topcoat) provides the designer with a virtually unlimited spectrum of colored finishes. The typical A/D FIREFILM 1I design thickness ranges from 16 mils (0.OI 6 inch) (0.40 mm) to 130 mils (O. 13 inch) (3.30 mm) to the structural steel members. However, under fire conditions the intumescent coating expands up to 4 in. thick, providing a fire resistant char around the structural members. Fire Test Standards and Listings: A/D FIREFILM IIhas been tested to some of the world's most stringent standards, the ASTM-E119 Fire Endurance test, as required by all five US model building Codes (UBC, SBCCI, BOCA, IBC, & NFPA) and UL 263 (ASTM-E119 with added environmental and aging testing). A/D FIREFILM II is listed by: Underwriters Laboratories, Inc. (UL), ITS / Warnock Hersey (WH), Factory Mutual (FM), and ULC. A/D FIREFILM II has additional approvals including City of Los Angeles Research Report, City Of NewYork MEA Number and others. Fire Resistance Ratings: A/D FIREFILM II is the most extensively tested water based thin-film intumescent fireproofing in North America. A/D FIREFILM Il has column members tested with UL, ULC, ITS / Wamock Hersey and Factory Mutual up to 3 hours. We have listed members with W/D's as small as 0.41 (equivalent to I/8" steel exposed on one surface) and are not limited to "W" sections. A/D FIREFILM [I is also tested for tube steel, round, .square and rectangular sections. A/D FIREFILM I1 has beam, beam / floor assemblies tested with "W" sections as small as a W6 x 12 (W/D=0.S I ) from 3/4 thru 2 hours. A/D FIREFILM II is the only thin-film product listed by UL and ULC with an alternate thickness equation from 3/4 thru 2 hours. A/D F[REFILM H ina Class 1 clean room 1i3 FIREFILM* II THE WORLD'S LEADER IN WATER BASED THIN-FILM INTUMESCENT FIREPROOFING CLEAN ROOM / STERILE FACILITIES: WHY MD FIREFILM® II ? Specific to integrated circuit fabrication, sterile and hygienic industrial facilities, nine key factors related to the selection of fire protection systems are: Dust free 2) No Off-Gassing from the Materials 3) Ease of Installing Attachments 4) Installation and Life Cycle Costs 5) No Mineral Wool Flute Fill Required 6) Durability 7) Speed of Application and Job Site Friendly 8) Job Site Safety 9) Smooth Finish - Cleaning Dust Free and Non Off-Gassing: A/D FIREFILM II provides a fireproofing option for the structural steel which does not contribute particulate matter into the environment. Furthermore, by virtue of its water-based formulation, A/D FIREFILM II does not off-gas after drying. Ease of Installing Attachments: In most cases, attachments can be made directly over A/D FIREFILM II without further treatment, avoiding and / or minimizing the hidden costs of patch work and time delays. By comparison, drywall and conventional fireproofing products require removal and repair of product which will create dust. With drywall and conventional fireproofing products, attachments are very expensive (usually hidden costs, generally adding 30 to 40% to the original sub contract) and time consuming, especially after the building is commissioned. A/D FIREFILM II allows the owner the ability to add, move, and remove attachments after the building is in operation. Attachments directly over A/D FIREFILM H A/D FIREFILM Il on structural steel No Mineral Wool Flute Fill Where fluted metal decks are used over beams most intumescent fireproofing designs require the open area between the top of the beam and the top of the deck to be filled with mineral wool, Mineral wool is known to be friable and the absorption of moisture risks mold growth. A/D FIREFILM II designs do not require mineral wool fill thus providing a particulate free product. .Durability: A/D FIREFILM II is the hardest interior fireproofing product on the market with a Shore "D" hardness of 531.8 (a bowling ball has a Shore "D" of I00). It is also one of the densest with a density of 85 pc[ Speed of Application for Re-Coating and Topcoating Typically A/D FIREF1LM II is re-coated after drying overnight and topcoated after 24 hours. Solvent based inturnescents typically require many days to weeks under favorable conditions before topcoating. Conventional fireproofing may take many days under favorable conditions before sealer coat and topcoat can be applied. Job Site Safety A/D FIREFILM II is water based with 0 VOC's unlike solwmt based products that typically add 2.5 lbs + of toxic: VOC's per gal. to the immediate environment. With A/D FIREFILM II other trades can work in the area during application without the ill effects of toxic solvents. Gas or propane heaters can be used without the risk of fire or explosion. A/D FIREFILM II is water clean up no solvents such as;toluene, MEK, MIBK, xylene, or paint thinner associated with solvent based intumescent are required. Speed of Application and Job Site Friendly A/D FIREFILM II is easy to appl)~ Most applicators use off the shelf conventional airless paint equipment. A/D FIP~EFILM II has proven to be substantially faster to install than conventional fireproofing. Also, it is more accommodating of other trades working in the area. With no solvent odors there is less need to isolate the application from other trades; a critical consideration, especially in fast-track construction. /~D FIREFILM® II allows easy access jot installation and maintenance of service items Smooth Painted Appearance Allows for Ease of Cleaning The A/D FIREFILM II system can easily be cleaned "including alcohol washed" during its service life. The smooth finish allows this to be done effectively and quickly Topcoats Multiple types and brands of topcoats have been tested and approved for use over A/D FIREFILM II. Patching Most fireproofing products are prone to being damaged easily as a result of other trades working in the area and from attachments to the structural steel during construction and the life of the building. A/D FIREFILM II requires only simple preparation and touch up of any damaged areas. We provide dear and simple patching procedures which allow the owner the flexibility to make ongoing changes without costly and time consuming disruptions in the operation of the facilityThe A/D FIREFILM II system easily accommodates the hanging of equipment from structural members with clamps and bolted connections to the structure. Space Savings The typical A/D FIREFILM II design thickness ranges fr<)m [ 6 mils (0.0 [ 6 inch) to [ 30 mils (0.13 inch) on ff~e structural steel members. Unlike drywall and conventional fireproofing methods, it does not intrude into valuable room/floor space and column "footprints" are kept to a minimum size. Weight Savings The A/D FIREFILM II system typically weighs less than 0.46 lb. per sq. Pc. This is much less than conventional fireproofing systems that weigh up to 7.5 lbs. per sq. ft.. This can be a significant factor in the building design and is usually a hidden costs when doing final calculations of the overall bearing capacity of the foundation, structural frame, etc..Typically the foundation, beams, trusses, and columns are designed to accommodate the heavier systems. However, this excess load bearing capacity can be,. reserved for future expansion requirements. A/D FIREFILM II '~ Drywall Fireproofing Column footprints and beam contours are smaller where ?dD FIREFILM II is used. Physical Performance Characteristic Comparison Chart Hardness (Shorn D) 81.8 23 to 55 Not Reported* Dry £)ensity (lbs. per cu, ft.) 85 40 to 47 Not Reported' Cohesion/Adhesion (Bond orTensile) I0,887 Ibf/ft2 3,369 to 10,000 Ibf/ft2 Requires Mechanical (ASTM 736) (Test was modified for coating) Attachment Pull-off Strength (ASTM D454 I) 3 I, 176 Ibf/ft2 Not Reported* Not Reported' Compressive strength (ASTM- 157,680 Ibf/ft2 52,992 to 79,200 psf Not Reported' E761-86) @ 10% deformation Deflection (ASTM E759-92) Pass Pass Not Reported' Impact Resistance 103 in-lb direct @ 65 mils Not Reported* Not Reported* (ASTM D2794) 286 in4b direct @ 120 mils Abrasion Resistance 0, 174 g wear index 174 Not Reported~ Not Reported* (ASTM D4060-90) at 1,000 cycles Volatile Organic Compounds 0 Not Reported* Not Reported* (VOC) (ASTM D3960-920) Surface Burning Characteristics Class I (A) Class I (A) Class I (A) ASTM E84 Off-Gassing per: Intel Off GassTest Pass Not Reported' Not Reported' NASA SP R-0022A Pass Not Reported' Not Reported' ASTM E595 Pass Not Reported' Not Reported' ESA PSS-01-702 Pass Not Reported' Not Reported' Dust Free / Air Erosion Pass / 0.0 grams / sq ft Sealer Required / Not Reported* (ASTM E859) Varies by product Attaching Hangers / Clips to the Direct to AD FIREFILM li Material must be removed Not Recommended Fireproofin~ in most cases to the steel and patched Cleaning / Maintenance of Smooth cleanabie surface Uneven surface very Must be sealed coated Products difficult to clean to allow for cleaning Ease of Application Sprayed, Brushed or. Sprayed, hand trowelled Furred, fastened, taped Rolled and sealed and sealed Weight / Ibf/ft~ 0.46 @ 0.065 in. thick Up to psf @ I in. thick Up to 7.5 psf pH Level 7-8 I I 13 Not Reported* fi MARTIN F. SENDLEWSKI, A.I.A. ARCHITECT -- PLANNER August 23, 2005 Town of Southold Building Department PO Box 1179 Southold, NY 11971 Attn: Mike Verity Re: Southold Fire District Permit No. 29169 Z - Exit signs Dear Mr. Verity: This correspondence is to certify that this office reviewed all exit sign installations at the above noted project and that said installations have been corrected in acc°rdance Wi?o~:e requirements in accOrdance with yOur final inspecti°n'Ve~ truly y~ Martin F. Sendl~wski A.I.A. Cc~ Southold Fire District ) 215 ROANOKE AVENUE · RIVERHEAD, N.~ 11901 · (631) 727-5352 · FAX [631 ) 727-5335 MARTIN F. SENDLEWSKI, A.I.A. ARCHITECT -- P~NNER August 23, 2005 Town of Southold Building Department PO Box 1179 Soutbold, NY 11971 Attn: Mike Verity Re: Southold Fire District Permit No. 29169 Z - plumbing Certification Dear Mr. Verity: This correspondence is to certify that all plumbing installations at the above noted project have been installed in compliance with code requirements and that no lead solder was utilized for domestic water supply installations. Ve~! )~s, Martin F. Sendlewski A.I.A. Cc: Southold Fire District 215 ROANOKE AVENUE · RIVERHEAD, N.Y. 11901 · [631 ) 727-5352 · FAX (631) 727-5335 MARTIN F. SENDLEWSKI, A.I.A. ARCHITECT -- PLANNER August 23, 2005 Town of Southold Building Department PO Box 1179 Southold, NY 11971 Attn: Mike Verity Re: Southold Fire District Permit No. 29169 Z - Interior fimshes Dear Mr. Verity: This correspondence is to certify that this office reviewed and approved all interior finishes including carpeting, wall covering, ceiling tile, etc. at the above noted project and that the flame spread rating is class A or B as required for their installation in all areas Very truly yo~'i l I/~--A.i.A. Martin F. Se~n~le~wski Cc: Southold Fire District 215 ROANOKE AVENUE · RIVERHEAD, N.Y. 11901 · (631) 727-5352 · FAX [631 ) 727-5335 MARTIN F. SENDLEWSKI, A.I.A. ARCHITECT -- PLANNER September 15, 2004 Town of Southold Building Depmhnent Box 1179 Southold, NY 11971 Attention: Mr. Mike Verity RE: Southold Fire District Dear Mr. Verity: Please note that I have been engaged by the Southold Fire District ~o assist them in contract administra6on regarding the construction of the Southold Fire District main firehouse addition. Based on our field reviews, it appears that the structural steel frame and masonry wall constxuction have been installed in accordan~th the intent of the original building permit documents. Very tml~y°urs' Martin F. ewski, AIA MFS/Ia Cc: Southold Fire District 215 ROANOKE AVENUE · RIVERHEAD, N.Y, 11901 · [631 ) 727-5352 · FAX (631) 727-5335 Fax (516) 765-1823 Telephone (516) 765-1800 Town Hall, 53095 Main Road P.O. Box 1179 Southold, New York 11971 SOUTHOLD TOWN LANDMARK PRESERVATION COMMISSION TO: FROM: DATE: RE: Southold Town Building Department Southold Town Landmark Preservation Comm. - Herb Adler, Jr, March 3; 2003 Southold Fire District at 55135 Main Rd., Southold Tax Map #62-1-11.1, SPLIA No. SD-67 The Landmark Preservation Commission has reviewed the additions to be made to the firehouse and approves the drawings for same. MARTIN F. SENDLEWSKI, A.I.A. ARCHITECT -- PLANNER September 1, 2004 Town of Southold Building Department Box 1179 Southold, NY 11971 Attention: Mr. Mike Verity RE: Southold Fire District Addition Dear Mr. Verity: Upon completion of the reviews between this office, Rich Smith and yourself, final revised permit plans have been delivered as required to finalize the permit process and as required to complete all inspections at this time. I would like to arrange to meet with you again at the project site possibly next Wednesday, September 8, 2004 prior to our regularly scheduled job meeting to complete said inspections. It is also required that I submit the waivers for the basemem stair and main stair as well as the rating of the enclosure at the existing from egress stair for a waiver thru your office to Mr. Smith of Regional Codes Division. Upon your receipt of this can be coordinated. corresponden~3contaet me so that said meeting Very m~ Martin F. Sendlewski, AIA MFS/la Cc: Southold Fire District Bill Glass, Attorney 215 ROANOKE AVENUE · RIVERHEAD, N.Y. 11901 · [631 ) 727-5352 · FAX (631) 727-5335 MARTIN F. SENDLEWSKI, A.I.A. ARCHITECT -- P NNER July 28, 2004 Town of Southold Building Department Box 1179 Southold, NY 11971 Attention: Mr. Mike Verity RE: Southold Fire District Addition 2 2OO4 Dear Mr. Verity: In accordance with our meeting OF July 20, 2004 with Rich Smith of the New York State Codes Division, I have again revised the three (3) attached sets of plans as required for issuance of the final building permit. The revision specifically include the following: 1. An additional exterior door is not required from the basement stair to the exterior. 2. The flint floor corridor shall a minimum 1-hour rating and all doom shall minimum "C" label. 3. Door shall be provided at opening between new addition and existing building as previously discussed to enclose first floor exit comdor. Stairs from landing to first floor and basement shall be built in accordance with code requirements or waiver will be required. Drawings have been revised to indicate proper stair dimensions as required for permit. 5. Enclosure and door shall be provided between second floor comdor and exit stair. 6. Existing east exit door from second floor meeting room will not be counted as an exit, 7. Door between hallway and meeting room shall be omitted. 215 ROANOKE AVENUE · RIVERHEAD, N.Y. 11901 · (631) 727-5352 · FAX [631 } 727-5335 8. Existing ornamental stair shall be altered to provide 1 hour rated exit enclosure. 9. Elevator shall be installed per original plan. Pit will be altered to accommodate stop at all levels. At this time, we are requesting that the permit be issued and that the framing, plumbing, insulation and electrical inspections all be completed as soon as possible in that at this time all areas have been lei~ open as required for inspection. In addition to the above, please note that the kitchen hood has been omitted and the electrical contractor shall provide all fire alarm information as required for final acceptance. It is our understanding upon completion of the above, only a final inspection will be required for thc issuance of a Certificate of Occupancy. Please also note that in addition to the above we have provided a copy of~he certification of existing sanitary system and related site plans associated with sai~fc~rtification for your record. Should Very t~ Martin ¢_~ndlewski, AIA MFS/la Enclosure Cc: Southold Fire District MARTIN F. SENDLEWSKI, A.I.A. ARCHITECT -- PLANNER September 15, 2004 Town of Southold Building Department Box 1179 Southold, NY 11971 Attention: Mr. Mike Verity RE: Southold Fire Dislxict Building Permit Drawings Dear Mr. Verity: This correspondence is to certify that I have prepared the revisions to the previously submitted permit drawings in accordanc/~with our previous reviews. Said revisions are indicat~l on the permit drawings da~d~uly 14, 2004. Very tml yoUrs, Martin F. ~ndlewski, AIA MFS/la Cc: Southold Fire District 215 ROANOKE AVENUE · RIVERHEAD, N.Y. 11901 · (631) 727-5352 · FAX [631 ) 727-5335 MARTIN F. SENDLEWSKI, A.I.A. ARCHI~CT -- PLANNER September 15, 2004 Town of Southold Building Department Box 1179 Southold, NY 11971 Attention: Mr. Mike Verity RE: Southold Fire District Sanitary System Alterations Dear Mr. Verity: This correspondence is to certify that a application to the Suffolk County Health Depmh~lent has been completed and submitted as required for improvements to the sanitary system in conjunction with this project. Please note that prior to issuance of Certificate ~ Occupancy, a final approved site plan will be provided to you. Very truly yours, j Sen~wski, AIA Martin F. MFS/la Cc: Southold Fire District green stamp 215 ROANOKE AVENUE · RIVERHEAD, N,~ 11901 · (631) 727-5352 · FAX (631) 727-5335 MARTIN F. SENDLEWSKI, A.I.A. ARCHITECT -- PLANNER July 28, 2004 Town of Southold Building Department Box 1179 Southold, NY 11971 Attention: Mr. Mike Verity RE: Southold Fire District Dear Iv'a-. Verity: In accor~y field observations and inspections, this correspondence is to certify that th~.~ the Southold Fire District addition ha~ been installed in accordance ~d~Mat~of the Contract Documents ~ Code Requirements. MFS/Ia 215 ROANOKE AVENUE · RIVERHEAD, N,Y. 11901 · (631) 727-5352 · FAX (631 ] 727-5335 MARTIN F. SENDLEWSKI, A.I.A. ARCHITECT -- PLANNER Town of Southold Building Department Box 1179 Southold, NY 11971 Attention: Mr. Mike Verity July 28, 2004 RE: Southold Fire District Dear Mr. Verity: This correspondence is to certi~ that the rough plumbing installations have been installed in accordance with the intent of the Contract Documents and the Plumbing Code of the State of New York. ~ 215 ROANOKE AVENUE [] RIVERHEAD, N.Y. 11901 [] [631 ) 727-5352 [] FAX [631 ) 727-5335 Schaardt & Fullan, de Silva Architects, PLLC 690 Broadway Massapequa, New York 11758 Telephone: 516-541-8835 Fax: 516-541-8251 E-mail: sfdarch@optonline.net www.sfdarchitects.com February 4, 2003 Town of Southold Building Department 53095 Main Road PO Box 1179 Southold, NY 11971-1179 Re: Addition to Southold Firehouse 5513 Main Road Southold, NY 11971 This is to confirm that I have inspected the footings and foundations as installed for the above referenced project. All work observed, including the modifications due to field conditions, has been installed in accordance with the design intent of the construction documents and governing codes. Sincer~ Paul de Silva Principal Southold Fire District Ravco Construction File Schaardt & Fullan, de Silva, Architects PLLC Page 1 October 7, 2003 765-1802 BUILDING DEPT. INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ]FRAMING [ p~FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION REMARKS.-- 765-1802 BUILDING DEPT. DATE [ ] FRAMING [ ]FINAL [ ] FIREPLACE & CHIMNEY REMARKS: ~ INSPECTION [ ] FO~DATION 1ST [ ] ROUGH PLBG. [~"'FOUNDATION 2ND [ ] INSULATION 765-1802 BUILDING DEPT. INSPECTION [ ]/~UNDATION 1ST [ [ /~ FOUNDATION 2ND [ [ ] FRAMING [ [ ] FIREPLACE & CHIMNEY ROUGH PLBG. INSULATION FINAL REMARKS: DATE 765-1802 BUILDING DEPT. ~...~INSPECTION [~/] FOUNDATION 1ST [ ] ROUGH PLBG. [ ]FOUNDATION 2ND [ ] INSULATION [ ]FRAMING [ ]FINAL [ ]FIREPLACE & CHIMNEY _ DATE INSPECTOR TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING/STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY i/~ FIRE SAFETY INSPECTION DATE ////~~/' ~)~-/' ,NSPECTOR~~~ / MARTIN F. SENDLEWSKI, A.I.A. ARCHITECT -- PLANNER August 23, 2005 Town of Southold Building Department PO Box 1179 Southold, NY 11971 Attn: Mike Verity Re: Southold Fire District Dear Mr. Verity: As per our telephone conversation attached please find all information as required for the issuance of the final certificate of occupancy for the Southold Fire District: Completed Certificate of Occupancy Application. Copy of original building permit. Additional certification from this office for drawing revisions. Copy of Suffolk Cotmty Department of Health inspection certificate. Electrical Inspection Certificate. Architects certification for footings and foundation. Steel inspection report and certification. Certification from this office for steel frame and masonry installations. Elevator certification. Fire safety inspection including fire alarm and kitchen hood. Interior surface flame spread rating certification from this office. Plumbing certification from this office. Fireproofing repair information and certification. Exit sign repair certification. 215 ROANOKE AVENUE · RIVERHEAD, N,Y. 11901 · [631 ) 727-5352 · FAX [631 ) 727-5335 Please advise us as soon as the certificate of occupancy is ready so that we may pick it up at your off.ice and the project files can be closed out. Thank you for the assistance that you provided to this office and the district which has resulted in the facility being completed in compliance with intent of the New York State Uniform Fire Prevention and Building Code in effect at the time of issuance of permit. Cc~ Southold Fire District William Glass, Attorney FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 29169 Z Date FEBRU~RY 28, 2003 Permission is hereby granted to: FIRE DISTICT SOUTHOLD PO BOX 908 SOUTHOLD,NY 11971 for : CONSTRUCTION OF A TWO STORY ADDITION & ALTERATIONS TO Ai~ EXISTING BUILDING AS APPLIED FQX & TO THE CONDITIONS OF THE NYS BUILDING CODE / at premises located at County Tax Map No. 473889 Section 062 pursuant to application dated DECEMBER Building Inspector to expire on AUGUST 55135 MAIN RD SOUTHOLD Block 0001 Lot No. 011.001 26, 2002 and approved by the 28, 2004. Fee $ 0.00 COPY Rev. 5/8/02 MARTIN F. SENDLEWSKI, A.I.A.. ARCHITECT -- PLANNER September 15, 2004 Town of Southold Building Department Box 1179 Southold, NY 11971 Attention: Mr, Mike Verity RE: Southold Fire District Building Permit Drawings Dear Mr. Verity: This correspondence is to certify that I have prepared the revisions to the previously submitted permit drawings in accordanc~with our previous reviews. Said revisions are indicated on the permit drawings d~6d~uly~ 14, 2004. Very trifles, Martin F. ~endiewski, AIA MFS/la Cc: Southold Fire District 215 ROANOKE AVENUE · RIVERHEAD, N.Y. 11901 · (631) 727-5352 · FAX [631 ) 727-5335 O1 Schaardt & fullan, de Silva Architects, PLLC 690 Broadway Massapequa, New York 11758 To-. euhone; ~ 1¢>.§41-8835 ~ax 516-541-B251 E-r,;aik ~[darch~opton~ine, net www.sfda rch[tects,¢um February 4, 2003 !::e: Addition to Soutnold Fllehouse 55'13 Mafn Ro~d Southold, NY 1197~ this is to confirm that 1 have Inspect~d [he footlnt~s and foundations ~¢ ins[ailed for the abova mferen~d proj~t, All wor~ obse~ed, incl~din[~e nx~dif;cations due to field (onditions, has been instalLed in accordance wi~ the design intent of the constructbn docu~en!.~ and ~vernln~ codes, 5:ncerely, ,¢ Paul de Silva Principal Souttlol¢ Fife Oi~rict Ravco Conslruclioi~ !"tie Schsardt & Fulisn, de Silva, Architecte PLLC octob~¢ 7, 2003 , O.~ p.3 MUNICIPAL TESTING LABORATORY, INC DAILY ]NSgF.¢:'rlON REPoffr FArO LOCATJO'N O~ INg~OTION: $OCOl~ FJoor For ~ia inspeaion the comra~ end shop ~ra~ngs ~re revi~e~. OBSERVA'I'iONII: First fl ~or Every boJted connection on the second fJeor WeS inspected The. connections were feum;I in good torque co~ditior~ wlt'"l proper stick-au~, A325 TC t;olls were used. Looe, e bolts were four'4 in auYeral Ioca~ons where ~he TC gun had iL-nite,'t clrtving cleareo, ce. wrench was used to tight [hem un der the inspector wa+.ch 2. The second deck was tacked in p a~e, Inspected anct found acceptable, {:onolusion: th. wo~k in the second floor ia co,replete and found acceptable MARTIN F. SENDLEWSKI, A.I.A. ARCHI CT -- PLANNER September 15, 2004 Town of Southold Building Department Box 1179 Southold, NY 11971 Attention: Mr. Mike Verity RE: Southold Fire District Dear Mr. Verity: Please note that I have been engaged by the Southold Fire District io assist them in contract administration regarding the construction of the Southold Fire District main firehouse addition. Based on our field reviews, it appears that the sm~ctural steel flame and masonry wall consbmcfion have been installed in accordan~ivith the intent of the original building permit documents. ~ Very tml~yo ~ur: s, Martin F.Y S~~ewski, AIA MFS/Ia Cc: Southold Fire District i L . j 215 ROANOKE AVENUE · RIVERHEAD, N.~ 11901 · [631 ) 727-5352 · FAX (631) 727-5335 ThyssertKrupp Elevator April 1, 2005 revco Construc*don Inc. auijding//~, ~239 Robie 112, Suite ~edford, ~Y It765 CERTIFICATE OF COHPLIANCE Job Name:. Soul. Id Fire OJsffict $51~$ Hain Road $outho~d, NY Job # 111~19177 Wa completed an acceptance test of one (1) hydraulic passenger erevator at the aoove men~oned job $i~e, This teat was conduc~e,~ i~1 accordance with the appllcab/a pro~'~edures o~tfined In the American Naflena! Standard Sa/cry Code for Elevators and EscalatorS. ANSI/ASHE a17.1.2002 and the A~erlcan Na~onal Standard Inspectors' Honual for E~evator and Escalators ANSt/ASH£ A17.2.2-2001. The results of this test indicate that the equipment f~rnJshed and instalbd by Thysser Krupp Elevator Company is fumi$~ert and installed In compliance with the appticable reC. ulations of ~e~o codes. Very truly yours, Steve Der~ison G,E,I. Ins~,ector #1-.472 1~ 05 southold ~ipe district 6317656~14 765-1802 BUILDING DEPT. INSPECTION p.1 FOUNDATION 1ST FOUNDATION 2ND FRAMING [ ] ROUGH PLBG. [ ] INSULATION ] FINAL [ ] FIREPLACE & CHIMNEY ~,! FIRE SAFETY INSPECTION REMARKS: O&/,U. V.:- ' DATE INSPECTOR ''., ~, :':>,' ! "' .......... Schaardt & Fullan, de Silva Architects, PLLC 690 Broadway Massapequa, New York 11758 Telephone: 516-541-8835 Fax: 516-541~8251 E-mail: sfdarch@optonline.net www.sfda rchitects.com February 4, 2003 Town of Southold Building Department 53095 Main Road PO Box 1179 Southold, NY 11971-1179 ATT: Michael Verity Re: Addition to Southold Firehouse 5513 Main Road Southold, NY 11971 Dear Mike, This is to confirm our phone conversation of January 20, 2003 regardingthe above application, filed under the old code, as follows: Building Classification: The total building maximum fire area upon completion of this project will be 11,600 sf. The entire building will be classified in Use Group 4.2, Firehouse with assembly space. The construction class of the original structure is 4a, 1989 addition is 2b, and the current addition is 2b. Table V1-705 permits a maximum fire area of 12,000 sf under either 2b or 4a. Additionally this building is fully accessible on three sides, allowing a 75% increase to 21,000 sf. Therefore the building complies for area and class of construction. 2. The addition will be adding two small toilet rooms to the existing sanitary system. Filing with the Suffolk County Health Department is not required. The relocated pools on drawing A-1 are all storm drainage. The existing sanitary system is east of the .,~existing building, not near the new addition. The Basement Plan shown on drawing A2 is void. The Alternate Basement Plan shown on drawings 2A and 2B is proposed to be built. This cellar area will be used ~ for storage only. It is provided with two exits as required by code and will have exit lights and emergency lighting. 4. All exit requirements of the State Building Code for both the existing building and the new addition have been met, Schaardt & Fullan, de Silva, Architects PLLC Page 1 Februa~ 4, 2003 5. In accordance with your review, the following changes will be made: a. The entire first floor corridor of the addition will be constructed with a 2-hour fire rating. Doors will be B label. A new 2-hour partition and B label door will be added between Lobby 120 and Lobby 106. b. A new 2 hr partition and B label door will be added separating the Second Floor Lobby 208 from the Stair. c. The vanity counter in Room 212 will be reduced to provide 5 feet clear at the water closet as per ADA. d. The roof deck for the addition will be changed to non-combustible metal. The Fire District and I really appreciate your prompt attention to this application. Your review was most helpful. Please contact me if you have any further concerns. Sincerely, Paul de Silva Principal Southold Fire District File Schaardt & Fullan, de Silva, Architects PLLC Pal[e 2 February 4, 2003 Envelope Compliance Report New York State Energy Conservation Construction Code COMcheck-EZ Sof~vare Version 2.4 Release 1 Data filename: C:~Program Files~Check\COMcheck-EZ~SOUTHOLD FIRE MEC CHECK.cck Section 1: Project Information Project Name: Designer/Contractor: Document Author: ADDITIONS AND ALTERATIONS TO, SOUTHOLD FIREHOUSE, MAIN STREET; SOUTHOLD, NY 11971 SCHAARDT & FULLAN, de SILVA ARCHITECTS PLLC, 690 BROADWAY, MASSAPEQUA, NY 11758 Paul de SILVA Section 2: General Information Building Location: Climate Zone: Heating Degree Days (base 65 degrees F): Cooling Degree Days (base 65 degrees F): Building Use Method of Compliance: Suffolk, New York lib 5750 730 Whole Building Method Building Type Floor Area Other 2223 Project Description (check one): __ New Constmcfion XAddition __Alteration __ Unconditioned Shell (File Affidavit) Section 3: Requirements Checklist Air Leakage, Component Certification, and Vapor Retarder Requirements Inspection Date All joints and penetrations are caulked, gasketed, weather-stripped, or otherwise sealed Approved (Y~) Fireplaces installed with fight fitting non-combustible fireplace doors Dampets integral to the building envelope are equipped with motorized dampers Cargo doors and loading dock doors are weather sealed Recessed lighting fixtures are sealed or gasketed Windows, doors, and skylights certified as meeting leakage requirements Component R-values & U-factors labeled as certified Initial Vapor retarder installed Climate-Specific Requirements Corflponent Name/Description Roof 1: Non-Wood JoisVRafter/Tmss Exterior Wall 1: CMU >8" with Integral Insulation Furring: Metal Window 1: Wood Frame, Double Pane with Low-E Clear, shgc 0.55 Door 1: Solid Floor 1: Unheated Slab-On-Grade, Vertical 2 ft. Gross Cavity Cont. Proposed Budget Area R-Value R-Value U-Factor U-Factor 3339 0.0 19.0 0.051 0.059 4688 0.0 0.0 0.273 0.090 112 ...... 0.250 0.598 48 ...... 0.350 0.142 130 --- 15.0 ...... (a) Budget U-factors are used for software baseline calculations ONLY, and are not code requirements. Envelope PASSES: Design 18% better than code Section 4: Compliance Statement The proposed envelope design represented in this document is consistent with the building plans, specifications and other calculations submitted with this permit application. The proposed envelope system has been designed to meet the New York State Energy Conservation Construction Code requirements in COMcheck-EZ Version 2.4 Release 1. When a Registered Design Professional has stamped and signed this page, they are attesting that to the best of his/her knowledge, belief, and professional judgment, such plans or specifications 9/~ in, compliance with this Code. Si t e " ' Vat ' Mechanical Compliance Report New York State Energy Conservation Construction Code COMcheck-EZ Software Version 2.4 Release 1 Data filename: C:~Program Files\Check\COMcheek-EZSSOUTHOLD FIRE MEC CHECK.cck Section 1: Project Information Project Name: Designer/Contractor: Document Author: ADDITIONS AND ALTERATIONS TO, SOUTHOLD FIREHOUSE, MAIN STREET; SOUTHOLD, NY 11971 SCHAARDT & FULLAN, de SILVA ARCHITECTS PLLC, 690 BROADWAY, MASSAPEQUA, NY 11758 Paul de SILVA Section 2: General Information Building Location: Suffolk, New York Climate Zone: I lb Heating Degree Days (base 65 degrees F): 5750 Cooling Degree Days (base 65 degrees F): 730 Building Use Method of Compliance: Whole Building Method Project Description (check one): __ New Construction __ Addition __ Alteration __ Unconditioned Shell (File Affidavit) Section 3: Mechanical Systems List Quantity System Type & Descrintion HVAC System I: Heating: Hydronic or Steam Coil, Hot Water / Cooling: Field-Assembled DX Systen~, Capacity >=135 - <240 kBtu/h, Air-Cooled Condenser / Single Zone w/Perimeter System Plant 1: Heating: Hot Water Boiler, Capacity >=300 - <2500 kBtu/h, Oil / Cooling: Condensing Unit, Capacity >--135 kBm/h, Condenser Air-Cooled Water Heating 1: Service Water Heater w/Circulation Pump Section 4: Requirements Checklist Requirements Specific To: HVAC System 1 [ ] 1. Speci~ed~quipment~~nsists~f~e~d~assemb~edc~mp~n~nts~~~iciencyd~cum~ntati~nrequired [ ] 2. Balancing and pressure test connections on all hydronic terminal devices [ ] 3. Integrated air economizer required [ ] 4. Motorized, automatic shutoffdampers required on exhaust and outdoor air supply openings - Exception: Gravity dampers acceptable in buildings <3 stories - Exception: Systems with flow rates 300 cfm or less where dampers are interlocked with fan Requirements Specific To: Plant 1 [ ] 1. Equipment minimum efficiency: Condensing Unit: 9.9 COP, 11.0 IPLV [ ] 2. Newly purchased heating equipment will meet the efficiency requirements - used equipment must meet 83% Et ~ maximum capacity [ ] 3. Systems with multiple boilers have automatic controls capable of sequencmg boiler operation [ ] 4. Hydronic heating systems comprised of a single boiler and >500 kBtu/h input design capacity include either a multistaged or modulating burner Requirements Specific To: Water Heating 1 [ ] 1. l-in. pipe insuhtion on circulation systems [ ] 2. Automatic on/offcontrol required foreirculating systems Generic Requirements: Must be met by all systems to which the requirement is applicable [ ] 1. Load calculations per 1997 ASHRAE Fundamentals [ ] 2. Plant equipment and system capacity no greater than needed to meet loads - Exception: Standby equipment automatically offwhan primary system is operating - Exception: Multiple units cuntrolled to sequence operation as a function of load [ ] 3. Minimum one temperature control device per system [ ] 4. Minimum one humidity eona'ol device per installed humidification/dehumidification system [ ] 5. Thermostatic contruls must have 5 deg. F deadband - Exception: Thermostats requiring manual changeover between heating and cooling [ ] 6. Automatic Controls: Setback to 55 deg. F (heat) and 85 deg. F (cool); 7-day clock, 2-hour occupant override, 10-hour backup - Exception: Continuously operating zones - Exception: 2 kW demand or less, submit calculations [ ] 7. Automatic shut-offdampers on exhaust systems and supply systems with airflow >3,000 erin [ ] 8. Outside-air source for ventilation; system capable of reducing OSA to required minimum [ ] 9. R-5 supply and return air duct insulation in unconditioned spaces R-8 supply and return air duct insulation outside the building R-8 insulation between duets and the building exterior when duets are part of a building assembly - Exception: Ducts located within equipment - Exception: Ducts with interior and exterior temperature difference not exceeding 15 deg. F. [ ] 10. Ducts sealed - longitudinal seams on rigid ducts; transverse seams on all ducts; UL 181A or 18lB tapes and mastics [ ] 11. Mechanical fasteners and sealants used to connect ducts and air distribution equipment [ ] 12. Hot water pipe insulation: I in. for pipes <=1.5 in. and 2 in. for pipes >1.5 in. Chilled water/refrigerant/brine pipe insulation: I in. for pipes <=1.5 in. and 1.5 in. for pipes >1.5 in. Steam pipe insulation: 1.5 in. for pipes <=1.5 in. and 3 in. for pipes >1.5 in. - Exception: Piping within HVAC equipment - Exception: Fluid temperatures between 55 and 105 deg. F - Exception: Fluid not heated or cooled - Exception: Runouts <4 t~ in length [ ] 13. Operation and maintenance manual provided to building owner [ ] 14. Balancing devices provided in accordance with 603.15 &Mechanical Code for New York State [ ] 15. Hot water distribution systems >=600 kBtu/h must have one &the following: a) controls that reset supply water temperature by 25% of supply/return delta T b) mechanical or electrical adjustable-speed pump drive(s) c) two-way valves at all heating coils d) multiple-stage pumps e) other system controls that reduce pump flow by at least 50% based on load - calculations required [ ] 16. Newly purchased service water heating equipment will meet the efficiency requirements [ ] 17. Water beater temperature controls: 110 deg. F for dwelling units or 90 deg. F for other occupancies [ ] 18. Hot water distribution systems >=300 kBtu/h must have one of the following: a) controls that reset supply water temperature by 25% of supply/return delta T b) mechanical or electrical adjustable-speed pump drive(s) c) two-way valves at all heating coils d) multiple-stage pumps e) other system controls that reduce pump flow by at least 50% based on load - calculations required [ ] 19. Gravity dampers, stair and elevator shaft vents equipped with motorized dampers [ ] 20. Exhaust air heat recovery required for systems 5,000 cfm or greater with more than 70% outside air fraction or specifically exempted [ ] 21. Kitchen hoods >5,000 cfm provided with 50% makeup air that is uncooled and heated to no more than 60 deg. F unless specifically exempted [ ] 22. Buildings with fume hood systems must have variable air volume hood design, exhaust heat recovery, or seprate makeup air supply meeting the following: a) 75% make up air quantity, and/or b) within 2°F of room temperature and/or c) no humidification d) no simultaneous heating and cooling Section 5: Compliance Statement The proposed mechanical design represented in this document is consistent with the building plans, specifications and other calculations submitted with this permit application. The proposed mechanical systems have been designed to meet the New York State Energy Conservation Construction Code requirements in COMcheck-EZ Version 2.4 Release 1. The design professional shall provide to the code enforcement official a written certification that the required HVAC tests, system balancing, etc., have been perfonned and the system is operating as designed. Thc design professional shall retain copies of the test reports to be provided to the code enforcement official, if requested. When a Registered Design Professional has stamped and signed this page, they are attesting that to thc best of his/her knowledge, belief, and professional judgment, such plans or specifications arc in compliance with this Code. Principal Mechanical Designer-Name Signature Date Mechanical Requirements Description New York State Energy Conservation Construction Code COMcheck-EZ Software Version 2.4 Release 1 Data filename: C:~rogram Files\Chack\COMcheck-EZ~OUTHOLD FIRE MEC CHECK.tek The following list provides more detailed description of the requirements in Section 4 of the Mechancal Compliance Report. Requirements Specific To: HVAC System 1 1. The specified cooling system consists of field-assembled components. Documentation must be submitted showing the system meets New York State Energy Conservation Code equipment efficiency requirements for a comparable package equipment type and capacity range. 2. Hydronic heating and cooling coils must be equipped with a way to pressure test counections and measure and balance water flow and pressure. 3. An integrated air economizer is required for individual cooling systems over 65 kBtu/h in the selected climate. An integrated economizer allows simultaneous operation of outdoor-air and mechanical cooling. 4. Outdoor air supply and exhaust systems must have motorized dampers that automatically shut when the systems or spaces served are not in use. Dampers must be capable of automatically shutting offduring preoccupancy building warm-up, cool-dom, and setback, except when ventilation reduces energy costs (e.g., night purge) or when ventilation must be supplied to meet code requirements. Both outdoor air supply and exhaust air dampers must have a maximum leakage rate of 3 cfm/fi2 at 1.0 in w.g. when tested in accordance with AMCA Standard 500. - Exception: Gravity (non-motorized) dampers are acceptable in buildings less than three stories in height. - Exception: Systems with a design outside air intake or exhaust capacity of 300 cfm (140 Us) or less that are equipped with motor operated dampers that open and close when the unit is energized and de-energized, respectively. Requirements Specific To: Plant 1 1. The specified heating and/or cooling equipment is covered by New York State Energy Conservation Code and must meet the following minimum efficiency: Condensing Unit: 9.9 COP, 11.0 IPLV 2. The specified heating equipment is covered by Federal minimum efficiency requirements. New equipment of this type can be assumed to meet or exceed New York State Energy Conservation Code requirements for equipment eff~ciency, Used equipment must meet 83% Et ~ maximum capacity. 3. Systems with multiple boilers have automatic controls capable of sequencing the operation of the boilers. 4. Hydronic heating systems comprised of a single boiler and >500 kBtu/h input design capacity include either a multistaged or modulating burner. Requirements Specific To: Water Heating 1 1. Piping for the specified circulating service hot water system must be insulated with a minimum of l-in. insulation having a conductivity no >0.28 Bm.in/(h. fi2.°F). 2. Circulating service hot water systems must have a time switch control that can automatically turn off the system during unoccupied hours, Generic Requirements: Must be met by all systems to which the requirement is applicable 1. Design heating and cooling loads for the building must be determined using procedures equivalent to those in Chapters 27 and 28 of the ASHRAE Handbook of Fundamentals or an approved equivalent calculation procedure. 2. All equipment and systems must be sized to be no greater than needed to meet calculated loads. A single piece of equipment providing both heating and cooling must satisfy this provision for one function with the capacity for thc other function as small as possible, within available equipment options. - Exception: The equipment and/or system capacity may be greater than calculated loads for standby purposes. Standby equipment must be automatically controlled to be off when the prima~y equipment and/or system is operating. - Exception: Multiple units of the same equipment type whose combined capacities exceed the calculated load are allowed if they are provided with controls to sequence operation of the units as the load increases or decreases. 3. Each heating or cooling system serving a single zone must have its own temperature control device. tem'~nal devices, and supply air diffusers. 15. Hot water distribution systems with total system capacities of 600 kBtu/h and greater must have controls that:a) automatically reset the hot water supply temperature, based on heating load, by at least 25% of the design supply-to-return water temperature difference orb) reduce pump flow by at least 50% of design flow rate by using- adjustable-speed drive(s) on pomp(s)- multiple-stage pumps allowing at least 1/2 of the total pump horsepower to be automatically turned off- control valves designed to modulate or step down and close as a function of load- other approved means (supporting documentation or calculations must be submitted). 16. Service water heating equipment must meet minimum Federal efficiency requirements included in the National Appliance Energy Conservation Act and the Energy Policy Act of 1992, which meet or exceed New York State Energy Conservation Code. New service water heating equipment can be assumed to meet these requirements. 17. Water-heating equipment must be provided with controls that allow the user to set the water temperature to 110 °F for dwelling units and 90 °F for other occupancies. Controls must limit output temperatures of lavatories in public facility restrooms to 110 °F. 18. Hot water space-heating systems with a capacity exceeding 300 kBtu/h supplying heated water to comfort conditioning systems must include controls that automatically reset supply water temperatures by representative building loads (including return water temperature) or by outside air temperature. Exceptions: - Where the supply temperature reset controls cannot be implemented without causing improper operation of heating, cooling, humidification, or dehumidification systems. - Hydronic systems that use variable flow to reduce pumping energy. 19. Stair and elevator shaft vents must be equipped with motorized dampers capable of being automatically clused during normal building operation and interlocked to open as required by fire and smoke detection systems. All gravity outdoor air supply and exhaust hoods, vents, and ventilators must be equipped with motorized dampers that will automatically shut when the spaces served are not in use. Exceptions: - Gravity (non-motorized) dampers are acceptable in buildings less than three stories in height above grade. - Ventilation systems serving unconditioned spaces. 20. Individual fan systems with a design supply air capacity of 5000 cfra or greater and minimum outside air supply of 70% or greater of the supply air capacity must have an energy recovery system with at least a 50% effectiveness. Exceptions: - Systems serving spaces that are not cooled and heated to <60 °F. - Commercial kitchen hoods (grease) classified as Type I by NFPA 96 - Systems exhausting toxic, flammable, paint, or corrosive fumes or dust If an air economizer is also required, heat recovery must be bypassed or controlled to permit air economizer operation. 2 I. Individual kitchen exhaust hoods larger than 5000 cfm must be provided with make-up air sized for at least 50% of exhaust air volume that is uncooled and either unheated or heated to no more than 60 °F Exceptions: - Where hoods are used to exhaust ventilation air that would otherwise exfiltrate or be exhausted by other Can systems. - Certified grease extractor hoods that require a face velocity no >60 fpm. 22. Buildings with fume hood systems having a total exhaust rate >15,000 cfm must either have variable air volume hood design, exhaust air heat recovery, or separate make up air supply. OWNER TOWN OF SOUTHOLD FORMER OWNER RES. SEAS. LAND IMP. /$z.$ aa VL. TOTAL PROPERTY RECORD CARD STREET ~'~' [~ VI LLAGE DIST. S ~ ~O'JOHrC( V¢¢fa~¢ ~PEOF BUILDING FARM CO~. CB. MICS. Mkt. Value DATE RE~RKS ~/~ - SUB. LOT Oo bL; ~6 2_ AGE BUILDING CONDITION NEW NORMAL BELOW ABOVE ~ ~ FARM Acre Value Per Value Acre Tillable FRONTAGE ON WATER Woodland FRONTAGE ON ROAD Meadowland DEPTH BULKHEAD House Plot Total*~' ~ DOCK Porc~ Porch Breezeway Petio Total 3Y×/~ ~- ~'~ Foundation Basement Ext. Walls Fire Place Type Robf Recreation Room Dormer Both Floors Interior Finish Heat Rooms 1st Floor tRooms 2nd Floor Driveway Dinette K. LR~ DP,. Schaardt & Fullan, de Silva Architects, PLLC 690 Broadway Massapequa, New York 11758 Telephone: 516-541-8835 Fax: 516-541-8251 E-maih sfda rch@optonline.net www.sfda rchitects.com February 4,2003 Town of Southoid Building Department 53095 Main Road PO Box 1179 Southold, NY 11971-1179 ATT: Michael Verity Re: Addition to Southold Firehouse 5513 Main Road Southold, NY 11971 Dear Mike, This is to confirm our phone conversation of January 20, 2003 regarding the above application, filed under the old code, as follows: 1. Building Classification: The total building maximum fire area upon completion of this project will be 11,600 sr. The entire building will be classified in Use Group 4.2, Firehouse with assembly space. The construction class of the original structure is 4a, 1989 addition is 2b, and the current addition is 2b. Table VI-705 permits a maximum fire area of 12,000 sf under either 2b or 4a. Additionally this building is fully accessible on three sides, allowing a 75% increase to 21,000 sf. Therefore the building complies for area and class of construction. 2. The addition will be adding two small toilet rooms to the existing sanitary system. Filing with the Suffolk County Health Department is not required. The relocated pools on drawing A-1 are all storm drainage. The existinA sanitary system is east of the existing building, not near the new addition. ~'-~--:-f~ 3. The Basement Plan shown on drawing A2 is void. The Alternate Basement Plan shown on drawings 2A and 2B is proposed to be built. This cellar area will be used for storage only. It is provided with two exits as required by code and will have exit lights and emergency lighting. 4. All exit requirements of the State Building Code for both the existing building and the new addition have been met. Schaardt & Fullan, de Silva, Architects PLLC Page 1 July 27, 2003 5. In accordance with your review, the following changes will be made: a. The entire first floor corridor of the addition will be constructed with a 2-hour fire rating. Doors will be B label. A new 2-hour partition and B label door will be added between Lobby 120 and Lobby :[06. b. A new 2 hr partition and B label door will be added separating the Second Floor Lobby 208 from the Stair. c. The vanity counter in Room 212 will be reduced to provide 5 feet clear at the water closet as per ADA, d. The roof deck for the addition will be changed to non-combustible metal. The Fire District and I really appreciate your prompt attention to this application. Your review was most helpful. Please contact me if you have any further concerns. Sincerely, Paul de Silva Principal Southold Fire District File Schaardt & Fullan, de Silva, Architects PLLC Page 2 July 27, 2003 Schaardt & Fullan, de Silva Architects, PLLC 690 Broadway Massapequa, New York 11758 Telephone: 516-541-8835 Fax: 516-541-8251 E-mail: sfdarch@optonline.net www.sfda rc h itects.com February 4, 2003 Town of Southold Building Department 53095 Main Road PO Box 1179 Southold, NY 11971-1179 ATT: Michael Verity Re: Addition to Southold Firehouse 5513 Main Road Southold, NY 11971 Dear Mike, Enclosed are two sets of revised architectural drawings 1-14 hat reflected the changes you requested in your review. I am also enclosing a copy of my letter to you of February 14, 2003 that outlined our discussions. Please contact me if you have any further concerns. Sincerely,~/~ ,. Paul de Silva Principal Southold Fire District File Schaardt & Fullan, de Silva, Architects PLLC Page 1 August 11, 2003 Schaardt & Fullan, de Silva Architects, PLLC 690 Broadway Massapequa, New York 11758 Telephone: 516-541-8835 Fax: 516-541-8251 E-mail: sfdarch@optonline.net www.sfda rchitects.com Town of Southold Building Department 53095 Main Road PO Box 1179 Southold, NY 11971-1179 February 4, 2003 ATT: Michael Verity Re: Addition to Southold Firehouse 5513 Main Road Southold, NY 11971 Dear Mike, This is to confirm our phone conversation of January 20, 2003 regarding the above application, filed under the old code, as follows: 1. Building Classification: The total building maximum fire area upon completion of this project will be 11,600 sr. The entire building will be classified in Use Group 4.2, Firehouse with assembly space. The construction class ofthe original structure is 4a, 1989 addition is 2b, and the current addition is 2b. Table VI-705 permits a maximum fire area of 12,000 sf under either 2b or 4a. Additionally this building is fully accessible on three sides, allowing a 75% increase to 21,000 sr. Therefore the building complies for area and class of construction. 2. The addition will be adding two small toilet rooms to the existing sanitary system. Filing with the Suffolk County Health Department is not required. The relocated pools on drawing A-1 are all storm drainage. The existing sanitary system is east of the ..~existing building, not near the new addition. The Basement Plan shown on drawingA2 is void. The Alternate Basement Plan shown on drawings 2A and 2B is proposed to be built. This cellar area will be used ' ~ for storage only. It is provided with two exits as required by code and will have exit lights and emergency lighting. 4. All exit requirements of the State Building Code for both the existing building and the new addition have been met. Schaardt & Fullan, de Silva, Amhitects PLLC Page 1 February 4, 2003 5. In accordance with your review, the following changes will be made: a. The entire first floor corridor of the addition will be constructed with a 2-hour fire rating. Doors will be B label. A new 2-hour partition and B label door will be added between Lobby 120 and Lobby 106. b. A new 2 hr partition and B label door will be added separating the Second Floor Lobby 208 from the Stair. c. The vanity counter in Room 212 will be reduced to provide 5 feet clear at the water closet as per ADA. d. The roof deck for the addition will be changed to non-combustible metal. The Fire District and I really appreciate your prompt attention to this application. Your review was most helpful. Please contact me if you have any further concerns. Sincerely, Paul de Silva Principal Southold Fire District File Schaardt & Fullan, de Silva, Architects PLLC Page 2 Februapj 4, 2003 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL SOUTHOLD, NY 11971 TEL: (631) 765-1802 FAX: (631) 765-9502 www. northfork.net/Southold/ BUILDING PERMIT APPLICATION CHECKLIST Do you have or need the following, before applying? Board of Health 3 sets of Building Plans Planning Board approval Survey Check Septic Form N.Y.S.D.E.C. Trustees Contact: Mail to: 3'ca~a~q ~/~vt~4~ b~J~tv/l' APPLICATION FOR BUILDING PERMIT Date INSTRUCTIONS 17.-/7..6 ,20 oZ. a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 3 sets of plans, accurate plot plan to scale. Fee according to schedule, b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application, the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e. No building shall be occupied or used in whole or in part for any purpose What so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim, the Building Inspector may authorize, in writing, the extension of the pein'fit for an addition six months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Bnilding Zone Ordinance of the Town of Southold; Suffolk County, New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described, The applicant agrees to comply with all applicable laws, ordinances, building code, housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. (Signature of applicant or name, if a corporation) (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder Name of owner of premises rio t,,t ~/'q ~' ~- ~ ]"~/R I~ ~D 1 5'/r~ } C 7 (As on the tax roll or latest deed) If app_,li/c,~nt i~)t corpflration,t~na~e of duly authorized officer J (Name and ~Fe of corporate officer) Builders License No. Plumbers License No. Electricians License No. Other Trade's License No. 1. Location of land on which proposed work will be done: House Number Street County Tax Map No. 1000 Subdivision (Name) Section Hamlet Filed Map N~'~? 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy /~/t2.¢ b. Intendeduseandoccupancy j:T//~.. 57,4%o*J 3. Nature of work (check which applicable): New Building Repair Removal 4. Estimated Cost t~/? '/~' 900 o 5. If dwelling, number of dwelling units If garage, number of cars 6. 7. Demolition Fee Addition ~x( Alteration Other Work (Description) (To be paid on filing this application) Number of dwelling units on each floor If business, commercial or mixed occupancy, specify nature and extent of each type of use. Dimensions of existing structures, if any: Front Height ~o ~ Number of Stories Dimensions of same structure with alterations or additions: Front ¢ g. 5" / Depth I ~, 6[- ~ ~ Height '~ / Number of Stories 8. Dimensions of entire new construction: Front ~ ~o ~-t Height 'g 0 t Number of Stories 9. Size of lot: Front '2 t~5','L~' ~ Rear %~, ¥ Depth_ ll7,6 t Rear 7 7. f? Rear 3~.17 / Depth Depth 5 7_ [, % o 10. Date of Purchase ~./% Name of Former Owner 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO ~ 13. Will lot be re-graded? YES__ NO ~( Will excess fill be removed from premises? YES )~ NO 14. Names of Owner ofpremises ~P.E blMrt,¢7 Address So~g~ NameofArchitect~ ~ ~ Address ~r~ NmneofContractor l~gco Co~37~to~ Address ~r~ 15 a. Is this prope~y within 100 feet of g tidal wetl~d or a freshwater wetl~d? *YES NO * IF YES, SOUTHOLD TO~ TRUSTEES & D.E.C. PERMITS MAY BE ~QUIRED. b. Is this prope~y within 300 feet of a tidal wetl~d? * YES~ NO * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. STATE OF NEW YORK) SS: COUNTY OF ) [~(4'd/~'' j:>~ 71 t"'L'/~ being duly sworn, deposes and says that (s)he is the applicant (Name of individual signing contract) above named, (S).eis he c¥;I 67 (Contractor, Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are tree to the best of his knowledge and belief; and that the work will be perforated in the manner set forth in the application filed therewith. Sworn to before me this ~- ~; day of ~ 20 o2.T Notary Public Signature of Applicant N 0~" - 01' - 40"E I--XIS'TIN~ A~A EXISTING T~EE TO ~MAIN EXIST'~ EXISTt~ EBUlLI21N¢ F.~. ~=b. 30.0' S ~° - EXISTIN~ GONE, N.Y'.5. OUTE .?.5 OEN. EXIST. SEPTIC. TANK LA~N STONE MONUMENT EXIST. EXIST, POLE NEH LANN /-~CESSPOOL ~ EXIST. CESSPOOL #2 /~ EXIST'~ GL_/POLE ~NI=~ GUR, B T'T'PICAL /~,EXISTI~ POLE EXIST. LINK FENCE EXIST, CONG. LOIN HALL EXIST. CONE. '~. EXIST. '-.- CONG. NO -.TH 5.¢.M,~. f~Bt~. # ~lO-O4-OOOg P'=20'-O" , J/INI3 '0k ." L~ ~7 ISSUE 12-0&-05 ~U~tl DRAWING#. SURVEY OF PROPERTY AT SOUTHOLD TOWN OF' SOUTHOLD SUFFOLK COUNTY, N.Y. 1000-62-01-11.1 SCALE: 1'--30' OCT, 51. 2002 AREA--2.1876 ACRES L/C. NO. 49618 (651, (6J1) 765-1797 P.O. 1250 TRAVELER STREET ~o.~oLo. ~.~ .971 N ~q° - OI' - 40''~= ~×I~-IN~ PA~t~IN~ ~TO~N POOL (2) MATCH POOL 4'-0" Hl~N POOL TO I~EMAIN ~Xl~T'~ H¥~P. ANT THO ~TO~.¥ ADDITION ~TAI~. ~ PLA'Tt=OI~M '~XIST'~ ~LL5 ONE PLACPOLE EXIST 5EP, VI~.E STONE MONUMENT MAIN N."r'.S. ROUTE 25 NO .TH I Nt=O , A'T'I ON: -I~OO ~AL. ~PTIC TANK * THl=l~J= AI~,,t-= NO I"~LL~ Y'IITNIN lBO' Ot= eEl=TIC ~XI~T'~ POLE DATE: ISSUE 0~-28-04 FO~ 5.C.H.D P~ELIMINAR% ~EVIE~ U¢l!ii t~XIST. (~) g'4~ x 4' OIliiIi;P ~OOL5 = DO0 ~.~. (2) 50~ PARKI~ A~5. ' ~ AT ALL STORM /~rD'~ ~ ~OOL~ ~. C~CULATrON5 / ~ FOR SIZE , ~ L~ Chi ~ OOL9 L~ACNIN~ ~OOL ~ EXIST . / -- ~OLE ~ I Pt~,OVII2E A B' ¢OLLA~ OP ~.Lt~AN GAND AROUND TAN~ AND LIiiA~.HIN~, POOL¢, T'r'P. 8'-0" ~'O" PROJECT#: 042~ CAD FILE: P,/ DRAWING#: L.I~ACHIN¢ tI~,I N<~ MIN. D SI N EiTAIL$ .T.s SP