Loading...
HomeMy WebLinkAbout28812-Z FORM NO. 4 TOWN OF SOUTHOLD BUILDING DEPARTMENT office of the Building Inspector Town Hall Southold, N.Y. CERTIFICATE OF OCCUPANCY No: Z-31375 Date: 01/06/06 THIS CERTIFIES that the building NEW DWELLING Location of Property: 570 MASON DR CUTCHOGUE (HOUSE NO.) (STREET) (HAMLET) County Tax Map No. 473889 Section 104 Block 7 Lot 2 Subdivision Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated SEPTEMBER 27, 2002 pursuant to which Building Permit No. 28812-Z dated OCTOBER 9, 2002 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is SINGLE FAMILY DWELLING WITH TWO CAR GARAGE, FRONT PORCH, REAR PATIO & SCREENED PORCH AS APPLIED FOR. The certificate is issued to GEOFFROY & DOMENICA PENNY (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL R10-02-0071 01/04/06 ELECTRICAL CERTIFICATE NO. 1191621 04/08/05 PLUMBERS CERTIFICATION DATED 11/26/05 PERFECTION PLUMBING AuthorizedSignature Rev. 1/81 -, Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT 6 Zoos TOWN HALL 765-1502 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept, of water supply and sewerage-disposal(S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead. S. Commercial building, industrial building,multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings (prior to April 9, 1957) non-conforming uses, or buildings and "pre-existing" land uses: 1. Accurate survey of property showing all property lines, streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied, the Building Inspector shall state the reasons therefor in writing to the applicant. �. Fees 1. Certificate of Occupancy-New dwelling$25.00, Additions to dwelling $25.00, Alterations to dwelling$25.00, Swimming pool $25.00,Accessory building$25.00, Additions to accessory building$25.00, Businesses $50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential $15.00, Commercial $15.00 Date, 111-3010.5 New Construction: V___ Old or Pre-existing Building: _ (check one) Location of Property: s 0 /' Kro nJ R . C Lt 4Q_ HouseNo. Street H�af et Owner or Owners of Property: (S C.v4TW y , Qo Mtn. PtAJnJ Suffolk County Tax Map No 1000, Section, 10 Block —j Lot P_ Subdivision Filed Map. Lot: r Permit No. a$$l01� Date of Permit. /D 090R_ Applicant: roeyi A,,t4 �S /G Fh Pelvev Health Dept.Approval: _Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: (check one) Fee Submitted: $ oZ S av o r ( Applicant Signature �' � 31375 FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 28812 Z Date OCTOBER 9, 2002 Permission is hereby granted to: G & D PENNY 570 MASON DRIVE CUTCHOGUE,NY 11935 for DEMO OF EXISTING DWELLING & CONSTRUCTION OF A NEW SINGLE FAMILY DWELLING WITH 2 CAR GARAGE, FRONT PORCH & REAR PATIO & SCREENED PORCH; FLOOD PM at premises located at 570 MASON DR CUTCHOGUE County Tax Map No. 473889 Section 104 Block 0007 Lot No. 002 pursuant to application dated SEPTEMBER 27, 2002 and approved by the Building Inspector to expire on APRIL 9, 2004 . Fee $ 2 , 302 .20 Authorized Signature ORIGINAL Rev. 5/8/02 ❑� [P CP Gf�CP CP[P[P[PCPCPCP rJ�[P C.I�CPCPCPLTCPCPLI�CPCPCPCPCI'aLI�L�CPCPCPCPCPCPCPCJ�cP[PCPLI�CPIJ�tJ�C.TGPGfCICI� I]° BY THIS CERTIFICATE OF COMPLIANCE THE 5 5 NEW YORK BOARD OF FIRE UNDERWRITERS 5 rj BUREAU OF ELECTRICITY rj 5 40 FULTON STREET — NEW YORK, NY 10038 5 CERTIFIES THAT 5 5 Upon the application of upon premises owned by 5 SABAT ELECTRIC GEOFF PENNY50 PAT LAN157 e� MASON DR. MATT T CKENY 11952, ��CUTCHOGUE NY 1193551 Located at DRQ MASON DR. CUTCHOGUE, NY 11935 tSj 5 5 Application Number: 1191621 Certificate Number: 1191621 5 c 5 Section: Block: Lot: Building Permit: BDC: ns11 1C Described as a Residential occupancy, wherein the premises electrical system consisting of 5 electrical devices and wiring, described below, located in/on the premises at: 5 First Floor, Second Floor,Attached Garage,Outside,Attic, 5 5 5 5 A visual inspection of the premises electrical system, limited to electrical devices and wiring to the extent detailed 5 5 herein, was conducted in accordance with the requirements of the applicable code and/or standard 5 promulgated by the State of New York, Department of State Code Enforcement and Administration, or other 5 5 5 authority having jurisdiction, and found to be in compliance therewith on the Day of 8th April,2005. 5 5 Name OTY Rate Ratine Circuit Tvoe 5 Miscellaneous 5 1-40 amp steam unit 5 5 new house 5 5 Alarm and Emergency Equipment 5 5 Transfer Switch 1 0 60amp 5 5 5 Sensor 1 0 Carbon Monoxide Appliances and Accessories S Dish Washer 2 0 1.2 KW LJ Exhaust Fan 5 0 F.H.P. 5 5 Oven 5 5 2 0 30 Amps 5 5 Hydro Massage Tub,Residential 1 0 5 Furnace 1 0 Oil 55 Air Conditioner 1 0 24.000 BTU 7 Air Conditioner 2 0 36.000 BTU 5 Air Conditioner 1 0 42.000 BTU 5 Panels 5 CSU 1 60 14 seal 5 Wiring and Devices 5 Continued on Next Page 1 of 2 5 5 This certificate may not be altered in any way and is validated only by the presence of a raised seal at the location indicated. 5 O CP CP cPCPCP CP CP rJ arJ acPr�cnr1CP C nCP CnCP cfacJ@PtSCPrfflD DrJ�cP E cPRIVIVE 'r r�t�r�cPcP rJ� rJ��Pc1cJ�r�cPcP rJcJ�cPrJ�r PrJ�rJ�rJ�rJ�cP�PrJcP cPtJ�PcP cPrJ�cfrlcPrJrJ�cPcP co t BY THIS CERTIFICATE OF COMPLIANCE THE S NEW YORK BOARD OF FIRE UNDERWRITERS 5 5 BUREAU OF ELECTRICITY 5 S 40 FULTON STREET — NEW YORK, NY 10038 5 CERTIFIES THAT 5 5 Upon the application of upon premises owned by 5 5 5 SABAT ELECTRIC GEOFF PENNY 50 PAT LANE 670 MASON DR. MATTITUCK, NY 11952, CUTCHOGUE, NY 11935 C5 e� Located at 670 MASON DR. CUTCHOGUE, NY 11935 Application Number: 1191621 Certificate Number: 1191621 5 5 5 Section: Block: Lot: Building Permit: BDC: ns11 �5 c1 Described as a Residential occupancy, wherein the premises electrical system consisting of s 5 electrical devices and wiring, described below, located in/on the premises at: 5 55 First Floor, Second Floor,Attached Garage,Outside,Attic, tt+� 7c A visual inspection of the premises electrical system, limited to electrical devices and wiring to the extent detailed 5 herein, was conducted in accordance with the requirements of the applicable code and/or standard 5 promulgated by the State of New York, Department of State Code Enforcement and Administration, or other 5 authority having jurisdiction, and found to be in compliance therewith on the5 Day of 8th April,2005. SName OTTY Rate Rating Circuit Type ,CJS, Outlet 126 0 Fixture 5 5 Fixture 122 0 Incandescent 5 Fixture 4 0 Fluorescent 5 5 Outlet 140 0 General Purpose 5 5 Receptacle 73 0 General Purpose 5 5 Switch 94 0 General Purpose 5 5 Dimmers 14 0 5 CSJ Receptacle 1 0 20 amp Laundry 5 L' Receptacle 1 0 30 amp Dryer 5 5 Paddle Fan 3 0 SDisconnect 4 0 60 amp Air Conditioner S S Receptacle 25 0 GFCI 5 5 Service 5 5 1 Phase 3W Service Rating 300 Amperes 5 Service Disconnect: 2 150 cb 5 5 Meters: l Seal rIN ,1 2 of 2 5C 5 This certificate may not be altered in any way and is validated only by the presence of a raised seal at the location indicated. im� s � s rn rs rn��rn�rn� 711 n TEL.765-1802 TOWN Or SOUTHOW OFFICE OF BUILDING INSPccroa P.O. Box 728 *rOWO SOUT HOLD, N.Y. 11971 C E R T I P I C A T I O N Date Building Permit No. Q-6$la - owner (: yr - Tlo y L pEitlN y (please yyprint P —� lumber �jl�'J�//?� (Please print) I certify that the solder used in the water supply system contains less than 2/10 of 1% lead. (plumber's signature) Sworn to before me this I �,•'— -J�L-day of _ Nn� I,� (0✓�� --- YYY hl--- Notary Public Notary Public, County MELANIE V.BROWN Nowy PWft fib of NNW Yak No.4OW12 OAMW In&M*County '^nmmbsion c„rk"Od.19,d 0 ng Albert J. Krupski,President �*OF SOUTy� Town Hall James King,Vice-President 53095 Route 25 Artie Foster .If, .IL P.O. Box 1179 Ken Poliwoda T ? Southold,New York 11971-0959 CA Peggy A. Dickerson G O Telephone(631)765-1892 OUNf'11 Fax(631)765-6641 BOARD OF TOWN TRUSTEES TOWN OF SOUTHOLD CERTIFICATE OF COMPLIANCE # 0083C Date 11/29/05 THIS CERTIFIES that the single-family dwelling At 570 Mason Dr. , Cutchogue Suffolk County Tax Map# 104-7-2 Conforms to the application for a Trustees Permit heretofore filed in this office Dated 3/27/02 pursuant to which Trustees Permit# 5530 Dated 4/24/02 Was issued, and conforms to all of the requirements and conditions of the applicable provisions of law. The project for which this certificate is being issued is for a single-family dwelling The certificate is issued to GEOFFRY AND DOMENICA PENNY owner of the aforesaid property. '0- Authorized Signature y rsf S06% %V'tCmiuv OV TOWN OF SOUTHOLD BUILDING DEPT. 765.1802 INSPECTION [ ] FOUNDATION 1 ST [ ] ROUGH PLBG. [ ) FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING FINAL I4 , [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION REMARKS: 11 - a-I - off DATE INSPECTOR o �o�yOF SOUpy�6 AL TOWN OF SOUTHOLD BUILDING DEPT. 765.1802 INSPECTION [ ] FOUNDATION IST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING I STRAPPING [FINAL A ; [ ] FIREPLACE &\ CHIMNEY [ ] FIRE SAFETY INSPECTION REMARKS: C=e-r•C-t9'� DATE /� ��� �s INSPECTOR "�y"` 765.1802 BUILDING DEPT. INSPECTION [ ] FOUNDATION 1 ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING FINAL [ ] FIREPLACE & CHIMNEDY. '[ ] FIRE SAFETY INSPECTION REMARKS: DATE r a O r INSPECTOR CA �(�2_tT 765.1802 BUILDING DEPT. INSPECTION [ ] FOUNDATION IST [ ) RO H PLBG. [ ] FOUNDATION 2ND [ INSULATION ( ] FRAMING [ ] FINAL [ ] FIREPLACE & CHIMNEY, REMARKS: ti�m DATEINSPECTOR � c M-1802 BUILDING DEPT. i NSPECTIO I [ ] FOUNDATION IST [ UGH PLBG.//a [ ] FO 2ND [ ] INSULATION ��// [ F ING [ ] FINAL [ FIREPLACE A CHIIMNE G-- REMRKS: ame Z=�f�e2i7`�. =� DATE �� INSPECT M-1802 BUILDING DEPT. -INSPECTION [ FOUNDATION 1STROUGH PLBG. [ l [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING [ ] FINAL [ ] FIREPLACE,& CHIMNEY REMARKS: DATE__Lim�kINSPECTOR 765-1802 BUILDING DEPT. SPECTION [ FOUNDATION IST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING [ ] FINAL [ ] FIREPLACE & CHIMNEY REMARKS: kA gwr DATE t/JL INSPECTOR . Jif)7{1'H T. TERRY ��� � — f`1u111 kou'l TOWN CLETLH f 4 R P O fto„ 1 170 $uulhold. Nc%�- 1-i rk 11'171 N_EGIS(RAR OF VITAL. S1'AT1S11CS �✓�^ IC_-0" Fra (5161 765. MARRIAGE OFFICI-R _ ��` ybO` Tcicrhurx 0101 RECORDS MANAGEMENT OFFICER FREEDOM OF INFORhMTION OFFICER OFFICE OF THE 'TOWN CLERK TOWN OF SOUTHOLD THIS IS TO CERTIFY THAT THE FOLLOWING RESOLUTION WAS ADOPTED BY THE SOUTHOLD TOWN BOARD AT A REGULAR MEETING HELD ON AUGUST 24, 1993 : RESOLVED that the Town Board of the Town of Southold hereby adopts two (2) new forms to be used under the Flood Damage Prevent regulations of the Code of the Town of Southold: "Floodplain Development Permit Application" [FDP(93) ] , and "Certificate of Compliance for Development in Special Flood Hazard Area [C/C(93) ] . ( TOWN OF SO-'J-(11019 A hudtt J Southold Town Clerk August 25, 1993 APPLICATION >y PAGE I of a TOWN OF SOUTHOLD rLOODPLAIN DEVELOPMENT PERMIT APPLICATION This form is to be filled out in duplicate. SECTTON I: GENERAL. PROVISIONS (APPLICANT to read and signl: 1. No work may start until a permit is issued. 2 The permit may be revoked if any false statements are made herein. 3. If revoked, all work must cease until permit is re-issued. 4. Development shall not be used or occupied until a Certificate of Compliance is issued. 5. The permit will expire if no work is commenced within six months of issuance. 6. Applicant is hereby informed that other permits may be required to fulfill local,state and federal regulatory requirements. 7. Applicant hereby gives consent to the Local Administrator or his/her representative to make reasonable inspections required to verify compliance. 8. I,THE APPLICANT,CERTIFY THAT ALL STATEMENTS HEREIN AND IN ATTACHMENTS TO THIS APPLICATION ARE,TO THE BEST OF MY KNOWLEDGE,TRUE AND ACCURATE. o f (APPLICANTS SIGNATURE), DATE !D // o 2— SECTION SECTION 2: PROPOSED DEVELOPMENT (To be completed by APPLICANT) NAME ADDRESS , // TELEPHONE APPLICAN 6 t P(;n/N y S7U M/fS+n+ DM (�w►Wt 73Y -SCo"O? BUILDER rum; n r vt(1Cle A 73 Y —5ik('l ENGINEER tw ICt� PROJECT LOCATION: To avoid delay in processing the application, please provide enough information to easily identify the project location. Provide the street address, lot number or legal description (attach) and, outside urban areas, the distance to the nearest intersecting road or well-known landmark. A sketch attached to this application showing the project locations would be helpful. 99D /✓?!hsps[! 6y. - tit ri��t�e C&+ -74K rV]?2 'J q7 3 E•7V 9 5 ea io tis fKlk oo 2— FDP(93) FDP(93) APPLICATION PAGE 2 OF G DESCRIPTION OF WORK (Check all applicable boxes) A- STRUCTURAL DEVELOPMENT ACTIVITY STRUCTURE TYPE ❑ New Structure ❑ Residential (1-4 Family) O Addition ❑ Residential (More than 4 Family) ❑ Alteration ❑ Non-residenoal (Floodproofing? ❑ Yes) ❑ Relocation O Combined Use (Residemial & Commercial) O Demolition 0 Manufactured (Mobile) Home (In Manu- ❑ Replacement factured Home Park? O Yes) ESTIMATED COST OF PROJECT S B. OTHER DEVELOPMENT ACTIVITIES: O Fill ❑ Mining O Drilling O Grading ❑ Excavation (Except for Structural Development Checked Above) ❑ Watercourse Alteration (Including Dredging and Channel Modifications) ❑ Drainage Improvements (Including Culvert Work) ❑ Road, Street or Bridge Construction O Subdivision (New or Expansion) O Individual Water or Sewer System ❑ Other (Please Specify) After completing SECTION 2, APPLICANT should submit form to Local Administrator for review. ,SECTION 3• FLOODPLAIN DETERMINATION (To be completed by LOCAL ADMINISTRATOR) The proposed development is located on FIRM Panel No. . Dated The Proposed Development: ❑ Is1M located in a Special Flood Hazard Area (Notify the applicant that the application review is complete and NO FLOODPLAIN DEVELOPMENT PERMIT IS REQUIRED). ❑ Is located in a Special Flood Hazard Area. FIRM zone designation is 100-Year flood elevation at the site is: Ft. NGVD (MSL) ❑ Uoavailabic O The proposed development is located in a floodway. FBFM Pancl No. Dated ❑ See Section 4 for additional instructions. SIGNED DATE ' APPLICATION a PAGE 3 OF a SECTION 4ADDITIONAL INFORMATION FT�UIRED�To he comnlctcd by LOCAL ADMINISTRATOR) The applicant must submit the documents checked below before the application can be processed_ ❑ A site plan showing the IocaGon of all exi9ting structures, water bodies, adjacent roads, lot dimensions and proposed development. ❑ Development plans,drawn to scale, and spccificatipns, including where applicable:details for anchoring structures, proposed elevation of lowest floor (including basement), types of water resistant materials used below the first floor, details of floodproofing of utilities located below the first floor and details of enclosures below the first floor. Also ❑ Subdivision or other development plans (If the subdivision or other development exceeds 50 lots or 5 acres,whichever is the lesser, the applicant must provide 100-year flood elevations if they are not otherwise available). 0 Plans showing the extent of watercourse relocation and/or landform alterations. ❑ Top of new fill elevation Ft. NGVD (MSL). 0 Floodproofmg protection level (non-residential only) Ft.NGVD (MSL). For floodproofed structures, applicant must attach certification from registered engineer or - architect. ❑ Certification from a registered engineer that the proposed activity in a regulatory floodway will not result inany increase in the height of the 100-year flood. A copy of all data and calculations supporting this finding must also be submitted. ❑ Other. SECTION 5• PERMIT DETERMINATION (To be completed by LOCAL ADMINIS'T'RATOR) I have determined that the proposed activity. A. 0 Is B. O Is not in conformance with provisions of Local Law if_, 19 . The permit is issued subject to the conditions attached to and made part of this permit. SIGNED , DATE If BOX A is checked, the Local Administrator may issue a Development Permit upon payment of designated fee. If BOX B is checked, the Local Administrator will provide a written summary of deficiencies. Applicant may revise and resubmit an application to the Local Administrator or may request a bearing from the Board of Appeals. APPLICATION a __ PAGE a OF a APPEAIS: Appealed to Board of Appeals? U Yes U No Hearing date: Appeals Board Decision --- Approved? U Yes U No Conditions SECTION G AS-BUILT ELEVATIONS (To be submitted by APPLICANT before Certificate of Compliance is issued) The following information must be provided for project structures. This section mast be completed by a registered professional engineer or a licensed land surveyor (or attach a certification to this apphwtion). Complete 1 or 2 below. 1. Actual(As-Built) Elevation of the top of the lowest floor, including basement(in Coastal Hieh Hazard Areas bottom of lowest structural member of the lowest floor, excluding piling and columns) is: FT. NGVD (MSL). 2. Actual (As-Built) Elevation of floodproofmg protection is FT. NGVD (MSL). NOTE: Any work performed prior to submittal of the above information is at the risk of the Applicant. SECTION 7• COMPLIANCE ACTION (To be completed by LOCAL ADMINISTRATOR) The LOCAL ADMINISTRATOR will complete this section as applicable based on inspection of the project to ensure compliance with the community's local law for flood damage prevention. INSPECTIONS: DATE BY DEFICIENCIES? ❑ YES ❑ NO DATE BY DEFICIENCIES? ❑ YES ❑ NO DATE BY DEFICIENCIES? ❑ YES ❑ NO SECT ION 8• CERTIFICATE OF COMPLIANCE(To be completed by LOCAL ADMINISTRATOR) Certificate of Compliance issued: DA'I'S BY: Attachment B SAMPLE CERTIFICATE OF COMPLIANCE for Development in a Special Flood Hazard Area TOWN OF SOUTHOLD CERTIFICATE OF COMPLIANCE FOR DEVELOPMENT IN A SPECIAL FLOOD HAZARD AREA (OWNER MUST RETAIN THIS CERTIFICATE) PREMISES LOCATED AT: PERMIT NO. PERMIT DATE OWNERS NAME AND ADDRESS: CHECK ONE: ❑ NEW BUILDING ❑ EXISTING BUILDING ❑ VACANT LAND THE LOCAL ADMINISTRATOR IS TO COMPLETE A. OR B. BELOW: A. COMPLIANCE IS HEREBY CERTIFIED WITH THE REQUIREMENTS OF LOCAL LAW # , 19 SIGNED: DATED: B. COMPLIANCE IS HEREBY CERTIFIED WITH THE REQUIREMENTS OF LOCAL LAW # , 19_, AS MODIFIED BY VARIANCE # DATED SIGNED: DATED: C/C(93 ) ` Albert J. Krupski, President Town Hall James King, Vice-President 53095 Route 25 Artie Foster ,ro D�j P.O. Box 1179 Ken Poliwoda y.2 Southold, New York 11971-0959 Peggy A. Dickerson Z Telephone (631) 765-1892 05Fax Fax (631) 765-1366 X01 � dao BOARD OF TOWN TRUSTEES TOWN OF SOUTHOLD April 26, 2002 Mr. Thomas Samuels Samuels & Steelman Architects 25235 Main Road Cutchogue, NY 11935 RE: GEOFFRY & DOMENICA PENNY 570 Mason Dr., Cutchogue SCTM#104-7-2 Dear Mr. Samuels: The Board of Town Trustees took the following action during its regular meeting held on Wednesday, April 24, 2002 regarding the above matter: WHEREAS, Samuels & Steelman Architects on behalf of GEOFFRY & DOMENICA PENNY applied to the Southold Town Trustees for a permit under the provisions of the Wetland Ordinance of the Town of Southold, application dated March 27, 2002, and, WHEREAS, said application was referred to the Southold Town Conservation Advisory Council for their findings and recommendations, and, WHEREAS, a Public Hearing was held by the Town Trustees with respect to said application on April 24, 2002, at which time all interested persons were given an opportunity to be heard, and, WHEREAS, the Board members have personally viewed and are familiar with the premises in question and the surrounding area, and, WHEREAS, the Board has considered all the testimony and documentation submitted concerning this application, and, WHEREAS, the structure complies with the standards set forth in Chapter 97 of the Southold Town Code, TERMS and CONDITIONS Tim Permittee Geoffry & Domenica Penny res at 570 Mason Dr. , Cutchogue N Y $ e as parr of the consideration for the issuance of the Permit does understand and prescribe to the fol- lowing: 1. That the said Board of Trustees and the Town of Southold are released from any and all damages, or deiass for damages, of sults arising directly or lndiready as a result of any,open- ation performed pursuant to this permit, and the said Permittee will, at his or her own expense, defend any and all such suits initiated by third parch, and the said Permittee assumes fall liability with respect thereto, to the complete exclusion of the Board of Trustees of the Town of Southold 2. That this Permit is valid for a period of 24 mo& which is considered to be the estimated time'required to complete the work involved, but should dromistan<a warrant, request for an extension may be made to the Board at a later date. 3. That this Permit should be retained indefinitely, or as long as the said Permittee wishes to maintain the strumae or project involved, to provide evidence to anyone concerned that auth- orization was originally obtained. 4. That the work involved will be subject to the inspection and approval of the Board or Its agents, and non-compliance with,the provisions of the originating application, may be cause for revocation of this Permit by resolution of the said Board 5. That there will be no unreasonable interference with navigation as a result of the work herein authorized. 6. That there shall be no interference with the right of the public to pass and repass along the beach between high and low water marks. 7. That if future operations of the Town of Southold require the removal and/or alterations in the location of the work herein authorized, or if, in the opinion of the Board of Trustees, the. work shall cause unreasonable obstruction to free navigation, the said Permittee will be required, upon due notice, to remove or alter this work or project herein stated without expenses to the Town of Southold 8. That the said Board will be notified by the Permittee of the completion of the work anth- orized. 9. That the Permittee will obtain all other permits and consents that may be required sup- plemental to this permit which may be subject to revoke upon failure to obtain same. i I , WHEREAS, the Board has determined that the project as proposed will not affect the health, safety and general welfare of the people of the town, NOW THEREFORE BE IT, RESOLVED, that the Board of Trustees approve the application of GEOFFRY & DOMENICA PENNY to demolish the existing dwelling and construct a new house. BE IT FURTHER RESOLVED that this determination should not be considered a determination made for any other Department or Agency, which may also have an application pending for the same or similar project. Permit to construct and complete project will expire two years from the date it is signed. Fees must be paid, if applicable, and permit issued within six months of the date of this notification. Two inspections are required and the Trustees are to be notified upon completion of said project. Fees: None Very truly yours, c2: C-- Albert J. Krupski, Jr. President, Board of Trustees AJK/lms i Board Of Southold Town Trustees SOUTHOLD, NEW YORK k PERMIT NO. 5:.130 __... DATE: ...April 26, 2.002 r` GEOFFRY &_.:DOMENICA. PEIy.NY...._.._........._........._... ISSUED TO ....................}a_�.... k Pursuant to the provisions of Chapter 615 of the Laws of 1 l the State of New York, 1893; and Chapter 404 of the Laws of the State of New York 1952; and the Southold Town Ordinance en- titled ."REGULATING AND THE PLACING OF OBSTRUCTIONS IN AND ON TOWN WATERS AND PUBLIC LANDS and the REMOVAL OF SAND, GRAVEL OR OTHER MATERIALS FROM LANDS UNDER TOWN WATERS;•.': and in accordance with the Resolution of The Board adopted at a meeting held on ...April _2.4,. 2 _..002........, and in consideration of the sum of x....200.,_00... ... paid by Geoffry & Domenica Penny . .... ................... .. . Cutchogue N. Y. and subject to the Terms and Conditions listed on the reverse side hereof, of Southold Town Trustees authorizes and permits the following: s' $' Wetland Permit to demolish the existing dwelling and construct a new house. >.. all in accordance with the detailed specifications as presented in the originating application. IN WITNESS WHEREOF, The said Board of Trustees here- by causes its Corporate Seal to be affixed, and thesepresents to F be subscribed by a majority of the said Board as of this date. z Trustees New York State Department of Environmental Conservation AM of Environmental Permits, Region One Building 40 - SUNY, Stony Brook, New York 11790-2356 Phone: (631)444-0365 • FAX: (631)444-0360 _ Website: www.dec.state.ny.us Erin M.Crotty Commissioner August 28, 2002 Geoffroy & Domenica Penny 570 Mason Drive Cutchogue, NY 11935 Dear Permittee: Re: Penny Property, 570 Mason Drive, Cutchogue No. 1-4738-00074/00005 In conformance with the requirements of the State Uniform Procedures Act (Article 70, ECL) and its implementing regulations (6NYCRR, Part 621), we are enclosing your permit and approved plans. Please read all permit conditions carefully. If you are unable to comply with any conditions, please contact us at the above address. Also enclosed is a permit sign, which is to be conspicuously posted at the project site and protected from the weather, and the dual Notice of Commencement/Completion of Construction. Please follow all instructions on the latter. Very truly yours, Karen S. Westerlind Environmental Analyst Enclosures: 4 cc: Samuels & Steelman NEW YORK STATE DEPARTMENT OF ENVIRONMENTAL CONSERVATION DEC PERMIT NUMBER EFFECTIVE DATE 1-4738.00074/00005 27 August 2002 FACILITY/PROGRAM NUMBER(S) PERMIT EXPIRATION DATE(S) Under the Environmental 31 August 2007 Conservation Law TYPE OF PERMIT■New ❑ Renewal ❑Modification■ Permit to Construct ❑ Permit to Operate ❑Article 15,Title 5: Protection of Waters ❑ Article 17,Titles 7,8: SPDES ❑ Article 27,Title 9; 6NYCRR 373: Hazardous Waste Management ❑ Article 15,Title 15:Water Supply ❑ Article 19:Air Pollution Control ❑ Article 34: Coastal Erosion ❑ Article 15,Title 15:Water Transport ❑ Article 23,Title 27: Mined Land Management Reclamation ❑ Article 15,Title 15: Long Island Wells ❑ Article 36: Floodplain Management ❑ Article 24: Freshwater Wetlands ❑ Article 15,Title 27: Wild, Scenic and ❑ Articles 1, 3, 17, 19, 27, 37; 6NYCRR Recreational Rivers ■Article 25:Tidal Wetlands 380: Radiation Control ❑ 6NYCRR 608:Water Quality Certifica- ❑ Article 27,Title 7; 6NYCRR 360: tion Solid Waste Management PERMIT ISSUED TO TELEPHONE NUMBER Geoffroy&Domenica Penn 631 734-5689 ADDRESS OF PERMITTEE 570 Mason Drive,Cutchogue, NY 11935 CONTACT PERSON FOR PERMITTED WORK TELEPHONE NUMBER Thomas C. Samuels, Samuels&Steelman (631)734-6405 25235 Main Road, Cutcho ue, NY 11935 NAME AND ADDRESS OF PROJECT/FACILITY Penny Property, 570 Mason Drive, Cutcho ue LOCATION OF PROJECT/FACILITY SCTM: 1000-104-07.02 COUNTY TOWN WATERCOURSE NYTM COORDINATES Suffolk Southold Haywaters Cove E: 713.8 N:4543.1 DESCRIPTION OF AUTHORIZED ACTIVITY Demolish existing single family dwelling and remove the existing septic system. Construct a new residence with an associated sanitary system. Remove the existing asphalt driveway. A pervious driveway with parking areas shall be installed. All work is to be done in accordance with the attached plans stamped NYSDEC approved. By acceptance of this permit, the permittee agrees that the permit is contingent upon strict compliance with the ECL,all applicable regulations,the General Conditions specified(see page 2&3)and any Special Conditions included as part of this permit. PERMIT ADMINISTRATOR: (KSW) ADDRESS George W. Hammarth, Region 1 Headquarters Deputy Permit Adminstrator Bldg. #40, SUNY, StonyBrook, NY 11790-2356 AUTHORIZED SIGNATURE DATEq / Page 1 of 4 NEW YORK STATE DEPARTMENT OF ENVIRONMENTAL CONSERVATION SPECIAL CONDITIONS 1. During construction,concrete or leachate shall not escape or be discharged, nor shall washings from transit mix trucks, mixers or other devices enter tidal wetlands and/or protected buffer areas. 2. Any debris or excess material from construction of this project shall be completely removed from the adjacentarea (upland)and removed to an approved upland area for disposal. No debris is permitted in tidal wetlands and/or protected buffer areas. 3. All areas of soil disturbance resulting from this project shall be stabilized immediately following project completion or prior to permit expiration, whichever comes first. The approved methodology is stabilization of the entire disturbed area with appropriate vegetation, such as grasses, etc. 4. The storage of construction equipment and materials shall be confined to within the projectwork site and or upland areas greater than 75 linear feet from the tidal wetland boundary. 5. All fill shall consist of"clean" sand, gravel, or soil (not asphalt, flyash, broken concrete or demolition debris). 6. Necessary erosion control measures i.e., haybales, silt fencing, etc. are to be placed on the downslope edge of any disturbed area. This sediment barrier is to be put in place before any disturbance of the ground occurs and is to be maintained in good condition until thick vegetative cover is established. 7. Roof runoff shall be directed to drywells as shown on the approved plans for immediate on-site recharge. 8. Driveways and parking areas shall be constructed of pervious material. 9. Sanitary system (bottom of tank and leaching pools) shall be located a minimum of 2' above seasonal high groundwater. DEC PERMIT NUMBER Geoffroy & Domenica Penny PAGE 4 of 4 1-4738-00074/00005 NEW YORK STATE DEPARTMENT OF ENVIRONMENTAL CONSERVATION ADDITIONAL GENERAL CONDITIONS FOR ARTICLES 15 (TITLE 5), 24, 25, 34 AND 6NYCRR PART 608 ( TIDAL WETLANDS) 1. If future operations by the State of New York require an alteration in the position of the structure or work herein authorized, or if, in the opinion of the Department of Environmental Conservation it shall cause unreasonable obstruction to the free navigation of said waters or flood flows or endanger the health, safety or welfare of the people of the State, or cause loss or destruction of the natural resources of the State, the owner may be ordered bythe Departmentto remove or alterthe structural work,obstructions,or hazards caused thereby without expense to the State, and if, upon the expiration or revocation of this permit, the structure, fill, excavation, or other modification of the watercourse hereby authorized shall not be completed,the owners,shall,without expense to the State,and to such extent and in such time and manneras the Department of Environmental Conservation may require, remove all or any portion of the uncompleted structure or fill and restore to its former condition the navigable and flood capacity of the watercourse. No claim shall be made against the State of New York on account of any such removal or alteration. 2. The State of New York shall in no case be liable for any damage or injury to the structure or work herein authorized which may be caused by or result from future operations undertaken by the State for the conservation or improvement of navigation, or for other purposes, and no claim or right to compensation shall accrue from any such damage. 3. Granting of this permit does not relieve the applicant of the responsibility of obtaining any other permission, consent or approval from the U.S.Army Corps of Engineers, U.S.Coast Guard, New York State Office of General Services or local government which may be required. 4. All necessary precautions shall be taken to preclude contamination of any wetland or waterway by suspended solids, sediments, fuels, solvents, lubricants, epoxy coatings, paints, concrete, leachate or any other environmentally deleterious materials associated with the project. 5. Any material dredged in the conduct of the work herein permitted shall be removed evenly,without leaving large refuse piles, ridges across the bed of a waterway or floodplain or deep holes that may have a tendency to cause damage to navigable channels or to the banks of a waterway. 6. There shall be no unreasonable interference with navigation by the work herein authorized. 7. If upon the expiration or revocation of this permit, the project hereby authorized has not been completed, the applicant shall,without expense to the State, and to such extent and in such time and manner as the Department of Environmental Conservation may require, remove all or any portion of the uncompleted structure or fill and restore the site to its former condition. No claim shall be made against the State of New York on account of any such removal or alteration. 8. If granted under 6NYCRR Part 608,the NYS Department of Environmental Conservation hereby certifies that the subject project will not contravene effluent limitations or other limitations or standards under Sections 301, 302, 303,306 and 307 of the Clean Water Act of 1977 (PL 95-217)provided that all of the conditions listed herein are met. 9. At least 48 hours prior to commencement of the project,the permittee and contractor shall sign and return the top portion of the enclosed notification form certifying that they are fully aware of and understand all terms and conditions of this permit. Within 30 days of completion of project, the bottom portion of the form must also be signed and returned, along with photographs of the completed work and, if required, a survey. 10. All activities authorized by this permit must be in strict conformance with the approved plans submitted by the applicant or his agent as part of the permit application. Such approved plans were prepared by Samuels & Steelman dated 3/22/02 and last revised 5/9/02. DEC PERMIT NUMBER Geoffroy & Domenica Penny PAGE 3 OF 4 1-4738-00074/00005 NEW YORK STATE DEPARTMENT OF ENVIRONMENTAL CONSERVATION NOTIFICATION OF OTHER PERMITTEE OBLIGATIONS Item A: Permittee Accepts Legal Responsibility and Agrees to Indemnification The permittee expressly agrees to indemnify and hold harmless the Department of Environmental Conservation of the State of New York, its representatives, employees, and agents ("DEC")for all claims, suits, actions, and damages, to the extent attributable to the permittee's acts or omissions in connection with, or operation and maintenance of,the facility or facilities authorized by the permit whether in compliance or not in compliance with the terms and conditions of the permit. This indemnification does not extend to any claims, suits, actions, or damages to the extent attributable to DEC's own negligent or intentional acts or omissions,or to any claims,suits, or actions naming the DEC and arising under Article 78 of the New York Civil Practice Laws and Rules or any citizen suit or civil rights provision under federal or state laws. Item B: Permittes's Contractors to Comply with Permit The permittee is responsible for informing its independent contractors,employees, agents and assigns of their responsibility to comply with this permit, including all special conditions while acting as the permittee's agent with respect to the permitted activities, and such persons shall be subject to the same sanctions for violations of the Environmental Conservation Law as those prescribed for the permittee. Item C: Permittee Responsible for Obtaining Other Required Permits The permittee is responsible for obtaining any other permits, approvals, lands, easements and rights-of-way that may be required to carry out the activities that are authorized by this permit. Item D: No Right to Trespass or Interfere with Riparian Rights This permit does not convey to the permittee any right to trespass upon the lands or interfere with the riparian rights of others in order to perform the permitted work nor does it authorize the impairment of any rights, title, or interest in real or personal property held or vested in a person not a party to the permit. GENERAL CONDITIONS General Condition 1: Facility Inspection by the Department The permitted site or facility, including relevant records, is subject to inspection at reasonable hours and intervals by an authorized representative of the Department of Environmental Conservation (the Department)to determine whether the permittee is complying with this permit and the ECL. Such representative may order the work suspended pursuant to ECL 71-0301 and SAIDA 401(3). The permittee shall provide a person to accompany the Department's representative during an inspection to the permit area when requested by the Department. A copy of this permit, including all referenced maps, drawings and special conditions, must be available for inspection by the Department at all times at the project site orfacility. Failure to produce a copy of the permit upon request by a Department representative is a violation of this permit. General Condition 2: Relationship of this Permit to Other Department Orders and Determinations Unless expressly provided for by the Department, issuance of this permit does not modify,supersede or rescind any order or determination previously issued by the Department or any of the terms, conditions or requirements contained in such order or determination. General Condition 3: Applications for Permit Renewals or Modifications The permittee must submit a separate written application to the Department for renewal,modification or transfer of this permit.Such application must include any forms or supplemental information the Department requires.Any renewal, modification or transfer granted by the Department must be in writing. The permittee must submit a renewal application at least: a) 180 days before expiration of permits for State Pollutant Discharge Elimination System (SPDES), Hazardous Waste Management Facilities(HWMF), major Air Pollution Control (APC)and Solid Waste Management Facilities (SWMF); and b) 30 days before expiration of all other permit types. Submission of applications for permit renewal or modification are to be submitted to: NYSDEC Regional Permit Administrator, Region 1, SUNY Bldg #40, Stony Brook NY 11790-2356 General Condition 4: Permit Modifications, Suspensions and Revocations by the Department The Department reserves the right to modify, suspend or revoke this permit in accordance with 6 NYCRR Part 621. The grounds for modification, suspension or revocation include: a) materially false or inaccurate statements in the permit application or supporting papers; b) failure by the permittee to comply with any terms or conditions of the permit; c) exceeding the scope of the project as described in the permit application; d) newly discovered material information or a material change in environmental conditions, relevant technology or applicable law or regulations since the issuance of the existing permit; e) noncompliance with previously issued permit conditions, orders of the commissioner, any provisions of the Environmental Conservation Law or regulations of the Department related to the permitted activity. DEC PERMIT NUMBER Geoffroy & Domenica Penny PAGE 2 OF 4 1-4738-00074/00005 FOUNDATION 1 FOUNDATION(IST) ddMlgW � . . ►' /�� Jr = �'� - ROUGH1: 1 it i �1� INSULATION , / STATE ENERGY CODE � I ■��/moi � • ' a'aEiL"'�����i.it.� y 0 ISM ADDITIONAL C1 I I EWA �� tvvYill Vr 00iuirtULL tSUlLillOUrtsK1V111 A1J?L1(_:A1'I0N CHECKL1S BUILDING DEPARTMENT Do you have or need the following,before applying TOWN HALL Board of Health SOUTHOLD, NY 11971 3 sets of Building Plans TEL: 765-1802 Survey PERMIT NO. -2S by/,) Fi Check Septic Form N.Y.S.D.E.C. Trustees Examined, 201).)– Contact: Approved— J01q 20j9 .)– Mail to: 2-C 23 S A4 Aw A'P A, Disapproved a/c e--u- e, 4n61 C _&I 11935 Phone: (6ZA ?3f1 - 61105— ' r Building Inspector 1 1 r 1 2 T 2002 APPLICATION FOR BUILDING PERMIT Date `1r2 - • a (Q0 20 0� i INSTRUCTIONS a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 3 sets of plans, accurate plot plan to scale. Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application, the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e. No building shall be occupied or used in whole or in part for any purpose what-so-ever until a Certificate of Occupan is issued by the Building Inspector. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk-County,New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances, building code, housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. i'gnature of applicant or name, if a corporation) rlhw/ R.✓.{ CfcTCttJ!'2Gri�',�y (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder A iR G 14 t TEcT Name of owner of premises CE C) F F 1R C A, Pr–t4 f4 x/ (as on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. Plumbers License No. ---- --- ---- To Y3 � IJ F_ tE R n1 Electricians License No. Other Trade's License No. 1. Location of land on which proposed work will be done: House Number Street Hamlet County Tax Map No. 1000 Section /CJ 4 Block q Lot 2_ — Subdivision Filed Map No. Lot (Name) Z. State existing use and occupancy of premises and intended use and occupancy of proposed construction: . a. Existing use and occupancy D ,./ pr L a t u (a b. Intended use and occupancy f') %./ e_ i II I u 6 i. Nature of work (check which applicable): New Building Addition Alteration Repair Removal Demolition Other Work (Description) I. Estimated Cost SUD.1 e ulr— Fee (to be paid on filing this application) If dwelling, number of dwelling units I Number of dwelling units on each floor / If garage, number of cars 2 If business, commercial or mixed occupancy, specify nature and extent of each type of use. Dimensions of existing structures, if any: Front Q B , 1 F�I Rear 49 1 F'r— Depth 5-2 .l FT Height 1 S' r i. Number of Stories I Dimensions of same structure with alterations or additions: Front 9O F�-IO lu Rear Depth ' 9�1 F= I j t i Height 3 I Ff. - s r IJ. Number of Stories Z Dimensions of entire new construction: Front en f�l - io 10 Rearo F i- ID /h(Depth �b 2 F T - f IN/. Height Z f Fr, — S' /A/, Number of Stories y Size of lot Front ( 39 .2 S F( Rear 6 r7 .r)1 FT, Depth 3_69>_56 Fi_ 0. Date of Purchase Name of Former Owner I. Zone or use district in which premises are situated :2•U D 2. Does proposed construction violate any zoning law, ordinance or regulation: No 3. Will lot be re-graded X E S Will excess fill be removed from premises: YES l GEOC'F2y� DCHEwIU . ;0 w1tiSc,�I OR�VE 4. Names of Owner of premises PE Num Address ccuteNeee,_E,iyyPhoneNo. Name of Architectss'.kiLL 4 Sree!.anN Addressjsa3sn4&.wAn. Phone No 734 g465- Name of Contractor Address Phone No. 5. Is this property within 100 feet of a tidal wetland? *YES ✓ NO • IF YES, SOUTHOLD TOWN TRUSTEES PERMITS MAY BE REQUIRED 6. Provide survey, to scale, with accurate foundation plan and distances to property lines. 7. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. TATE OF NEW YORK) SS: 'OUNTYOF smrsLc i frO►k S AMI.IELS being duly sworn, deposes and says that (s)he is the applicant (Name of individual signing contract) above named, �)He is the G F f.1 1� (Contractor, Agent, Corporate Officer, etc.) I said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; iat all statements contained in this application are true to the best of his knowledge and belief; and that the work will be sformed in the manner set forth in the application filed therewith. worn to before me this 0 __day of 200Q, C%; Notary Public Signature of Applicant PATRICIA RICHARDS Notary Public, State of New York No. 01R16042467 Qualified in Suffolk County Commission Expires May 30, 20W0lp I�UILD ANG-PE�- -T-� I fi -�( -i- o = Applicant Date. Owners Name: 61 Reviewed: lD OiZ Architect Date Engineer: i S Submitted: 1171 0 SCTM #: District: 1.000 Section: Block: �_ Lot: Project Subdivision Location: 7 0 rA-0's &,\,— T_ _ Name: Single & separate Required certification: (Yes/NoJ _ Req. Rcq. zoning Districl: (1,01 size: Actual: qt� IIAt coverage 1'rolxis� Req. / f / —Req. ✓ r Req. r jl'ronl ��)Yard �Proposed: ) (Side Yard S Pr/oposed: (Rear Yard _ '-V Proposed -AW J Project 5eVtiof: r j AGENCUERMITS Permit REQUIRED FOR REVIEW N.A. >NO YES Number Suffolk County Health Dept. New York State D. E. C. r/ Town Trustees Town Zoning Board approval: Town Planning Board approval: f -..-------..�T Flood Plane Elevation??? Flood Zone: 1'9 4) VOIC, 1041/ '4 AALO �,� pF SO(/jyol 0 Town Hall,53095 Main Road Fax(631)765-9502 P.O.Box 1179 G Telephone(631)765-1802 Southold,New York 11971-0959 �O BUILDING DEPARTMENT TOWN OF SOUTHOLD NOVEMBE 22, 2005 MR. &MRS. GEOFFRY PENNY 570 MASON DRIVE CUTCHOGUE,N.Y. 11935 To Whom It May Concern: We are unable to complete your Certificate of Occupancy because of the following reasons: J ✓ An application for Certificate of Occupancy is not on file. (Enclosed) No Electrical Certificate on file. 0(i— The Check is not on file. –$25.00 y No Health Department Approval on file. No final inspection has been made. No Plumber Solder Certificate on file. (All permits involving plumbing being issued after April 1, 1984.) A— BUILDING PERMIT#28812-Z (PREMISES @ 570 MASON DR., CUTCHOGUE) _N T : BEFORE CO CAN BE ISSUED FINAL INSPECTION REQUIRED BY THE SOUTHOLD TOWN TRUSTEES. �� Town Of Southold P.O Box 1179 Southold, NY 11971 * * * RECEIPT * * * Date: 09/27/02 Receipt#: 10341 Transaction(s): Subtotal 1 Septic Permit-Construct- Resid. $10.00 Check#: 10341 Total Paid: $10.00 Name: Samuels, &Steelman 25235 Main Rd Cutchogue, NY 11935 Clerk ID: LBOHN Intemal ID:62838 3UR1/E)' OF PROPERTY - 51TUATE: PEGONIGv��0 TOWN: 5MTHOLD o�ti Sten N ey 5UFFOLK COUNTY, NY op°5ed �. I SURVEYED 0I-12-00 AMENDED 02-05-02 prop, add. 03-02-02 SUFFOLK COUNTY TAX # o 1000-104--7-2 GERTIFIED TO: GEOFFROY L. PENNY 6 0 Test Hole 2/28/02 60 AT HIGH 6 TIDE CO m 41i CL ]ARK / Y 1 OAM Q , m c SM LOAMY ty SAND 111 QAn/i A \ p 2.5' �1 PALE ¢ Q TEST m V o� a /" FINE" HOLE �' L �� SP ° i MeowM j , sAno ' 9p W 3 v G T =f-i Q'- m-- 9 I P E ` 1� WATER00 6.] Op AAT R 9N. 5T I y� - F 1� IN PALE 1 aFOEN ISI O p „J��II sP Era M I AN \ rrI SANG o�vC p OP 5E I v fl o s' 8 7 \{O gee ND/ h � ��'S h� o 17 a � 21 I � s° ° McDonald I lPO O Ik�V„1 1J _M7V1'JA All JCC A I O 1p m I \ In O y ' i .. nl �JO. - O 0 A w] „ " ; �� � n I � / ., /ly• L �. III IN a I IJ 00 I , Iln 3 w. n vi I 3 r 1 i A mo v I i Ey�cc,`,`O NOTES: M..o. .—�z�,,.��,,,,. MONUMENT * * FLOOD ZONE INFORMATION ANNOTATED FROM FIRM #3610360164 6 DATED MAY 4, 1998 0 CONTOUR INFO. 15 REFERENGED TO NOVO '29 yS<p A2025JP.1`o 5OUTHOLD TOWN ZONE R- 40 AREA = 53,948 SF OR 124 ACRES JOHN C. EHLERS LAND SURVEYOR 6 EAST MAIN STREET N.Y.S.LIC.NO. 50202 G SGALE I"=40' - - RIVERHEAD,N.Y. 11901 REF.\\Hp server\d\PROS\99-266J.pro 369-8288 Fax 369-8287 — -- — - - - 5URYT=Y OF PROPERTY - - - -- 51TUATE: PEGONIG N Tom 50UTHOLD 5Uf=f--OLK GOMM NY SURVEYED 0I-12-00 AMENDED 02-05-02 prop. add. 03-02-02 / amen. 5ep. 05-02-02 ✓ O fnd lor. 01-15-03 RA slab elev. 02-I0-03 � V SUFFOLK GOUNTY TAX u 1000-104-1-2 CERTIFIED TO: GEOFFROY L. PENNY +p 103000 o 9 = q s w 26' 0 M - � N - 22 - 21 0 � 9 20' IGOnGfBtB ," 1 �" DQ SII gtl9 n 9 Found O _ 9 O T/50b N �'� •'- iq �iS O} iii lP 35A 111 S � ' 3 22' N fl � \ � o V 0 o a Of WW 9 3 N �q X09° I li % y Ih / y u r- S i NOTES: NO.'Su� ■ MONUMENT LAND .,th, AREA = 53,948 SF OR 1.24 ACRES [�a^5nM JOHN C. EHLERS LAND SURVEYOR GRAPHIC, 5GALE 1"=40' 6 EAST MAIN STREET N.Y.S.LIC.NO. 50202 RIVERHEAD,N.Y. 11901 - -------- - -- 369-8288 Fax 369-8287 REF.\\Hp server\d\PROS\99-266J.pro I > : 3/22/ =.SEPTIC, SITE DATA srne Ten-1041-: PROPERrv: FENNr RFs07ENCE ADRESS no Ylsox ORNE curc�w+iE.rgwraix SUE: Wi SOFT.=IMS AC AREA F: ZpINC: fl-N FLOCO: X Land nm a formerly of: - x Chalee Bayer. JrSURWEOR aONNC ENIFR9 K RNERNFM.RE.. SERVED BY LICENSEE %= r PUBLIC WATER OwTED:112-2=1 z /E\ NOTES. FORFLE Aw SMO y TO M& rz rVi I/ 2 Sk.Ow ARMC CORTOORB REFS Q M �� / R TOY 810:90 LT F110Y TOPOPoGRAPMIC r YIPSS OOF THE FW Q _ PROPSED RESIDENCE WILL BE TIED INTO 0 l \ ` ` +Q O PUBLIC WATER SUPPU®BY S.C.WA a �e y \ �� \+�'� TNELNONawTaus oFweuswxOOEssPoas Z 2 SN Nd1EON ARMOR FELE a F - S1s ek OBSERVATN0SMOOROATAOBTlJ1ED In O ' 1 - _ �'• �r \ I FRO.OT. O F 51276{O"E w / C) ; '� ' ~ , • , r�' I rI I To LOCATION MAP SORA VAIJ.T W. / p / I , T /j r/ I/ II i � It S � 3, Y,,... ?\ 'IIS a � T -.Wdr / �e _ _ • / ,rte r IAN I ♦}'. Ir r IY • \\i £ ^,1 _ + r' '♦"w�l / �1YaoRlN Laf/1Tlae ear \ w �- 1 51 PIELL To \ wea e�m `� 1 Irl 1 lA Z.. \'+ 0�\ \ T111111 \ \I r♦s .Y�s':'^`�`. .y -.. IH'AM116 pN1 \r 1W -7-% T 11BefINB :�_ �- '_�� s�// '\ .�� i>, _ - --- \. ,. 6 �/ TEST HOLE Mae .t'. .r ;-�', �r�I i - - - \,`\ \R\r ♦ C� _ \ _ MIT HoZ Q^TA 9B IO] ♦eO1L W J. ,G T LL"Yr re \ � y un. NrNNNNNNM'IRrI a � W. � � 8lIA5TC7NE \ w \ r/ —`\L r s wNlwvw M 'i W. ` 4 . m F]il•IC le01+FAfY li It # / _ ` I _ _ `T li l\ Bt ...v Q v N w" Land nor or fa mwiy of " ,�7�,� . w ur. (y a rt.NIe11 e x err.GIA �Acrme ra @l a rT.wAH x e R olA PUBLIC WATER DO WOH N NN.lf�1Nb/1e11/.M Ftbant of Lzist g sanitary system - -Mbe W Sed by Hdalth DepartmerR. I euILDINIS WALL SUFFOLK COUL Y 0'L B 1,. , • •:-J" IaL.k+-PH SERVICES - i PROPOSED GRADE LINE ELEVATION 19.5 FT. z,Ra PERMIT FOR APPROVAL O..F'CONSTRUMON FOR A „� .. .. ,. `- I' ..MIN2' MAX � RJB x SINGLE FAMILY RESIDENCE ONLY s --. 1/4"/PT. 2% 2 t R5EPTIG LEAGHINC, ,(9 SCALE: q�E 0. �L#y#r E. +85' TANK POOL t0.wkk, SHEET m E: I.t 4i? _ y Fop 1 BEDROOMS fi� 5A ft.� �14D R.---I - z i SITE PLAN EXPIRES tHi' A2 11 t"T n1: APPROVAL i► °"°u"o"A'e`a '°^. SEPTIC PROFILE SHEET NO �, Ab. 1830 N.T.S. 1 SUR\IEY OF PROPERTY N 51-MATE: MOON10 TOWN: 5OUTHOLD ell s SUFFOLK WMT'f, NY W -- E SURVEYED 01-12-00 AMENDED 02-05-02 amen. Qedpp. 05-02-02 fnd loc. OI-15-03 uj slab elev. 02-10-03 O FINAL 04-19-2005 SUFFOLK GOUNTY TAX It 00 0-104-1-2 v -P r CEeTWED TO: 9' GEOPFROY L.PIBNNY / 6 -00 �B \ I \ A)v\e- 21 o `� \c P m A P rye. v n �_ O 1 1 W 22 -- Qi 2 5to GOrage , O p� r 1 '11� !1 � step LU 1 1 6 \ 11 c- b 00 it .� • - SER - i . 1 w rm t NOTES: 63 ■ MONUMENT AREA = 53,948 5F OR 1.24 AGRE5 SUFFOLK COUNTY DET.OF HEALTH[ SERVICES REF.#RIO-02-0071 JOHN C. EHLERS LAND SURVEYOR 6 EAST MAIN STREET N.Y.S.LIC.NO. 50202 ORAPHIG 5GALE I"=40' _ RIVERHEAD,N.Y. 11901 REF.\\IIp server\flpros\99-266J.pro 369-8288 Fax 369-8287 Permi -PlutnbE[ i MECcheck Compliance Report Checked By/Date New York State Energy Conservation Construction Code MECcheck Software Version 3.3 Release lc Data filename: C:\Program Files\Check\MECcheck\PENNY.cck TITLE:NEW RESIDENCE COUNTY: Suffolk STATE:New York HDD: 5750 CONSTRUCTION TYPE: Detached 1 or 2 Family HEATING TYPE:Non-Electric DATE: 10/04/02 DATE OF PLANS:6/ 19/02 PROJECT INFORMATION: 2105 PENNY RESIDENCE 570 MASON DRIVE CUTCHOGUE,NY. 11935 COMPANY INFORMATION: SAMUELS AND STEELMAN ARCHITECTS 25235 MAIN ROAD CUTCHOGUE,NY. 11935 COMPLIANCE:Passes Maximum UA=741 Your Home=718 3.1%Better Than Code Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R•Value U-Factor UA Ceiling 1: Flat Ceiling or Scissor Truss 2152 30.0 0.0 75 Skylight V: Wood Frame,Double Pane 10 0.480 5 Wall l: Wood Frame, 16" o.c. 4446 19.0 0.0 195 Window A: Wood Frame,Double Pane with Low-E 18 0.320 6 Window B: Wood Frame,Double Pane with Low-E 75 0.320 24 Window C: Wood Frame,Double Pane with Low-E 50 0.300 15 Window D: Wood Frame,Double Pane with Low-E 200 0.320 64 Window E: Wood Frame,Double Pane with Low-E 55 0.320 18 Window F:Wood Frame,Double Pane with Low-E 50 0.320 16 Window G: Wood Frame,Double Pane with Low-E 60 0.300 18 Window H:Wood Frame,Double Pane with Low-E 17 0.300 5 Window 1: Wood Frame,Double Pane with Low-E 48 0.320 15 Window K: Wood Frame,Double Pane with Low-E 25 0.320 8 Window L: Wood Frame, Double Pane with Low-E 4 0.300 1 Window M: Wood Frame,Double Pane with Low-E 5 0.320 2 Window N: Wood Frame,Double Pane with Low-E 53 0.320 17 Window O: Wood Frame,Double Pane with Low-E 53 0.320 17 Window P: Wood Frame,Double Pane with Low-E 39 0.320 12 Window Q: Wood Frame, Double Pane with Low-E 11 0.320 4 Window R: Wood Frame,Double Pane with Low-E 22 0.320 7 Window S: Wood Frame,Double Pane with Low-E 4 0.300 1 Window U: Wood Frame,Double Pane with Low-E 74 0.320 24 Window W: Wood Frame,Double Pane with Low-E 22 0.320 7 Door 101: Solid 45 0.100 5 Door 102: Solid 21 0.310 7 Door 105: Glass 99 0.310 31 Door 104: Glass 54 0.310 17 Door 103: Glass 99 0.310 31 Floor 1: All-Wood Joist/Truss,Over Unconditioned Space 2152 30.0 0.0 71 Boiler 1:Other(Exept Gas-Fired Steam), 80 AFUE COMPLIANCE STATEMENT: The proposed building represented in this document is consistent with the building plans, specifications,and other calculations submitted with this permit application. The proposed systems have been designed to meet the New York State Energy Conservation Construction Code requirements. When a Registered Design Professional has stamped and signed this page,they are attesting that to the best of his/her knowledge,belief, and professional judgment,such plans or specifications are in compliance with this Code. u / {3nitder/Designer Date///0? MECcheck Inspection Checklist New York State Energy Conservation Construction Code MECcheck Software Version 3.3 Release 1 c DATE: 10/04/02 TITLE:NEW RESIDENCE Bldg. Dept, Use I Ceilings: [ ] 1. Ceiling 1: Flat Ceiling or Scissor Truss,R-30.0 cavity insulation Comments: I Above-Grade Walls: [ ] 1. Wall l: Wood Frame, 16" o.c., R-19.0 cavity insulation Comments: Windows: [ ] 1. Window A: Wood Frame,Double Pane with Low-E,U-factor: 0.320 For windows without labeled U-factors,describe features: #Panes_Frame Type Thermal Break? [ ] Yes[ j No Comments: [ ] 2. Window B: Wood Frame,Double Pane with Low-E,U-factor: 0.320 For windows without labeled U-factors, describe features: #Panes_Frame Type _Thermal Break? [ ]Yes [ ]No Comments: [ ) 3. Window C: Wood Frame,Double Pane with Low-E,U-factor: 0.300 For windows without labeled U-factors,describe features: #Panes_Frame Type Thermal Break? [ ]Yes[ ]No Comments: [ ] 4. Window D: Wood Frame,Double Pane with Low-E,U-factor: 0.320 For windows without labeled U-factors, describe features: #Panes_Frame Type Thermal Break? [ ]Yes[ ]No Comments: [ ] 5. Window E:Wood Frame,Double Pane with Low-E,U-factor:0.320 For windows without labeled U-factors,describe features: #Panes_Frame Type Thermal Break?[ ] Yes[ ]No Comments: [ ] 6. Window F: Wood Frame,Double Pane with Low-E,U-factor:0.320 For windows without labeled U-factors, describe features: #Panes_Frame Type Thermal Break? [ ]Yes[ ]No Comments: [ ] 7. Window G: Wood Frame,Double Pane with Low-E,U-factor:0.300 For windows without labeled U-factors,describe features: #Panes_Frame Type Thermal Break?[ ] Yes[ ]No Comments: [ ] 8. Window H: Wood Frame,Double Pane with Low-E,U-factor: 0.300 For windows without labeled U-factors, describe features: #Panes_Frame Type Thermal Break? [ ]Yes[ ]No Comments: ( ] 9. Window I: Wood Frame,Double Pane with Low-E,U-factor:0.320 For windows without labeled U-factors,describe features: #Panes_Frame Type Thermal Break? [ ]Yes [ ]No Comments: [ ] 10. Window K: Wood Frame, Double Pane with Low-E,U-factor: 0.320 For windows without labeled U-factors,describe features: #Panes_Frame Type Thermal Break? [ ] Yes [ ]No Comments: [ ] 11. Window L: Wood Frame,Double Pane with Low-E,U-factor: 0.300 For windows without labeled U-factors,describe features: # Panes Frame Type Thermal Break? [ ]Yes[ ]No Comments: [ ] 12. Window M: Wood Frame,Double Pane with Low-E,U-factor: 0.320 For windows without labeled U-factors,describe features: #Panes_Frame Type Thermal Break? [ ] Yes [ ]No Comments: [ ] 13. Window N: Wood Frame,Double Pane with Low-E, U-factor: 0.320 For windows without labeled U-factors,describe features: #Panes_Frame Type Thermal Break? [ ] Yes[ ]No Comments: [ ] 14. Window O: Wood Frame, Double Pane with Low-E,U-factor: 0.320 For windows without labeled U-factors, describe features: #Panes_Frame Type Thermal Break? [ ] Yes[ ]No Comments: [ ] 15. Window P: Wood Frame,Double Pane with Low-E,U-factor: 0.320 For windows without labeled U-factors,describe features: #Panes_Frame Type Thermal Break? [ ] Yes [ ]No Comments: [ ] 16. Window Q: Wood Frame,Double Pane with Low-E,U-factor:0.320 For windows without labeled U-factors,describe features: #Panes_Frame Type Thermal Break? [ ] Yes[ ]No Comments: [ ] 17. Window R: Wood Frame,Double Pane with Low-E,U-factor:0.320 For windows without labeled U-factors,describe features: #Panes_Frame Type Thermal Break?[ ] Yes [ ]No Comments: [ ] 18. Window S: Wood Frame,Double Pane with Low-E,U-factor: 0.300 For windows without labeled U-factors,describe features: #Panes_Frame Type Thermal Break? [ ]Yes[ ]No Comments: [ ] 19. Window U:Wood Frame,Double Pane with Low-E,U-factor:0.320 For windows without labeled U-factors,describe features: #Panes_Frame Type Thermal Break? [ ]Yes [ ]No Comments: ( ] 20. Window W: Wood Frame,Double Pane with Low-E,U-factor: 0.320 For windows without labeled U-factors,describe features: #Panes_Frame Type Thermal Break? [ ]Yes[ ]No Comments: I Skylights: [ ] 1. Skylight V:Wood Frame, Double Pane,U-factor: 0.480 For skylights without labeled U-factors,describe features: # Panes_Frame Type Thermal Break? [ ]Yes[ ]No Comments: I Doors: [ ] 1. Door 101: Solid,U-factor:0.100 Comments: [ ] 2. Door 102: Solid,U-factor:0.310 Comments: [ ] 3. Door 105: Glass,U-factor:0.310 #Panes_Frame Type Thermal Break? [ ] Yes[ ]No Comments: [ ] 4. Door 104: Glass, U-factor: 0.310 #Panes_Frame Type _Thermal Break? [ ] Yes[ ]No Comments: [ ] 5. Door 103: Glass,U-factor: 0.310 #Panes_Frame Type Thermal Break? [ ] Yes [ ]No Comments: I Floors: [ ] 1. Floor 1: All-Wood Joist/Truss, Over Unconditioned Space,R-30.0 cavity insulation Comments: Heating and Cooling Equipment: [ ] 1. Boiler 1: Other(Exept Gas-Fired Steam), 80 AFUE or higher Make and Model Number Air Leakage: [ ] I Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage must be sealed. [ ] Recessed lights must be 1)Type IC rated, or 2)installed inside an appropriate air-tight assembly with a 0.5" clearance from combustible materials. If non-IC rated,the fixture must be installed with a 3"clearance from insulation. I Vapor Retarder: [ ] Required on the warm-in-winter side of all non-vented framed ceilings,walls, and floors. I Materials Identification: [ 1 Materials and equipment must be installed in accordance with the manufacturer's installation instructions. [ ] Materials and equipment must be identified so that compliance can be determined. [ ] Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. [ ] Insulation R-values and glazing U-factors must be clearly marked on the building plans or specifications. I Duct Insulation: [ ] Supply ducts in unconditioned attics or outside the building must be insulated to R-8. [ ] Return ducts in unconditioned attics or outside the building must be insulated to R4. [ ] Supply ducts in unconditioned spaces must be insulated to R-8. [ ] Return ducts in unconditioned spaces(except basements)must be insulated to R-2. Insulation is not required on return ducts in basements. I Duct Construction: [ ] I All joints,seams,and connections must be securely fastened with welds,gaskets,mastics (adhesives),mastic-plus-embedded-fabric,or tapes. Duct tape is not permitted. Exception:Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in.w.g. (500 Pa). [ ] Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions. [ ] Cooling ducts with exterior insulation must be covered with a vapor retarder. [ ] Air filters are required in the return air system. [ ] The HVAC system must provide a means for balancing air and water systems. Temperature Controls: [ ] Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space temperature set point of the largest zone. Electric Systems: [ ] I Separate electric meters are required for each dwelling unit. Fireplaces: [ ] Fireplaces must be installed with tight fitting non-combustible fireplace doors. [ ] Fireplaces must be provided with a source of combustion air,as required by the Fireplace construction provisions of the Building Code of New York State,the Residential Code of New York State or the New York City Building Code, as applicable. Service Water Heating: [ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. [ ] Insulate circulating hot water pipes to the levels in Table 1. I I Circulating Hot Water Systems: [ j Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [ ] All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [ ] HVAC piping conveying fluids above 105°F or chilled fluids below 55 °F must be insulated to the levels in Table 2. Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non-Circulating Runouts Circulating Mains and Runouts Temperature(F) Up to 1„ Up to 1.25' 1.5"to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pine Sizes Piping System Types Range(F) 2" Runouts 1" and Less 1.25'to 2" 2.5'to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD(Building Department Use Only) WINDOW FEATURES I 8 Wood units with "K-Kron" finish, white 1 5/4 x 4" factory applied casings Factory mulled multiple units Low-E II insulating glass with Simulated divided(interior and exterior)lights with 7/8"glazing bars with spacer bars as shown on ELEVATIONS Matching screens in white Factory applied extension jambs of required width Egress function where applicable Standard interior hardware WINDOW SCHEDULE All dimensions shown are single unit frame dimension (w x h) Type Unit Size (H x W) Notes A WDH 2830 2@ 5' 10-1/8" x 2' 11-7/8" B WDH 3222 4' 6-1/8" x 3' 3-7/8" C SHE 36 6' 2" x 9' 2-1/2" D WDH 3224 2@ 4' 10-1/8" x 3' 3-7/8" E WDH 3228 5' 6-1/8" x 3' 3-7/8" F WDH 3624 4' 10-1/8' x3' 7-7/8" W/ WRT 36 DH 2' 1-7/16" x 3' 7-7/8" above w/ WDH 2424 2@ 4' 10-1/8" x 2' 7-7/8" on both sides G Custom made 4 fixed panel mulled unit w/overall height of 6' 2" x 12' 0" w/11' 6-1/4" radius H KW 30262 2' 8" x 6' 2-1/2" 1 WDH 3224 4' 10-1/8" x 3' 3-7/8" J KW 36201 2' 2" x 3' 8-1/2" K WDH 2016 3' 6-1/8" x 2' 3-7/8" L KWN 12 2' 2" x 1' 10-1/2" M KWW 2' 2" x 2' 2-1/2" FROSTED GLASS Penny 7 N WDH 2830 3@ 5110-1/8" x 2' 111-7/8" O WDH 2830 610-1/8" x 2' 11-7/8" P WDH 3230 5' 10-1/8" x 3' 3-7/8" Q WDH 2420 4' 2-1/8" x 2' 7-7/8" R WDH 2420 2@ 4' 2-1/8" x 2' 7-7/8" TEMPERED S WFC 2-0 2' 2" T WRT 40 DH 2' 3-7/16" x 3' 11-7/8" U WDH 3230 2@ 5' 10-1/8 x 3' 3-7/8" W/WDHS 5856 610-1/8 x5' 11-7/8" V SKS 2427 2'4" x 2'-0-1/2" ( ANDERSEN ) W WDH 2420 2@ 4' 2-1/8" x 2' 7-7/8" DOORS GENERAL Provide all doors as shown on PLANS and in SCHEDULE. Handle,store,fit,hang, prepare for finishing and finish as per manufacturer's directions. EXTERIOR WOOD DOORS Provide wood and glass exterior doors by MASTERMARK, Inc., with insulating glass. Provide vinyl bead weatherstrip and interlocking metal threshold. EXTERIOR GLASS DOORS Provide vinyl clad, "Frenchwood" gliding patio doors by ANDERSEN, Inc., with same features as windows and operable as shown. Provide white hardware and sliding screen panels. SCREEN/STORM DOORS Provide separate full light aluminum storm/screen combination door on front door#1, by ELMONT, Inc. EXTERIOR DOOR SCHEDULE # Unit a Size (H x W) Notes 101 2130 T611 x 6' 811 By Simpson w/2 5703 (I.G.) 1' 2" x 6' 8-1/2" w/ 4705 (I.G.) transoms above Penny 8 102 KK 6233 / 3070 3' 0" x 7' 0" 103 GAW 4-12080 8' 3-9/16" x 12' 0-9/16" 104 WXD 6080 8' 3-27/32" x 6' 5-3/8" 105 GAW 4-12080 8' 3-9/16" x 12' 0-9/16" INTERIOR DOORS Provide 1-3/8" thick doors. Bore all doors and jambs as required for finish hardware. INTERIOR DOOR SCHEDULE # Unit type Size (H x W) Notes 107 7' 0" x2' 6" 108 7' 0" x2' 6" 109 TO" x 2' 6" 110 pocket TO" x 3' 0" 111 7' 0" x2' 6" 112 2@ 7' 0" x2' 0" 113 fire rated TO" x TO" 114 7' 0" x2' 0" 115 2@ 7' 0" x2' 6" 116 2@ TO" x 1' 6" 117 7' 0" x2' 6" 118 7' 0" x2' 6" 119 fire rated 6' 8" x Toll 201 6' 8" x2' 8" 202 pocket 6' 8" x 2' 6" 203 6' 8" x2' 6" 204 6' 8" x 1' 10" 205 pocket 6' 8" x 2' 6" 206 6' 8" x 1' 10" 207 pocket 6' 8" x 2' 10" 208 6' 8" x 2' 8" 209 6' 8" x 2' 4" 210 6' 8" x2' 8" 211 pocket 6' 8" x 2' 611 212 6' 8" x2' 8" 213 6' 8" x2' 6" 214 6' 8" x2' 0" 215 6' 8" x2' 6" Penny 9 7 ................... ..................... SITE DATA SCTM # 1000-104-7-2 PROPERTY: PENNY RESIDENCE ADRESS 570 MASON DRIVE CUTCHOGUE, NEW YORK SITE; 53,948 SO. FT. = 1.2385 AC. Land now or formerly of: AREA �Ihr Charles Boyer, Jr. ZONING: R-40 SERVED BY PUBLIC WATER FLOOD: X ZONE Uj SURVEYOR: JOHN C. EHLERS 0 RIVERHEAD, NY. LICENSE # 50202 W ocy DATED: 1-12-2000 z z A/ �?o z 0 0 Bulkhead 0 NOTES: FOR ELEVATIONS AND 0Q1 /�cc) , I - <'o TOPOGRAPHIC CONTOURS REFER TO M.S.L. DATUM & RESULT FROM TOPOGRAPHIC 1�e — — — — — — — — — -- conc. MAPS OF THE FIVE TOWNS. pad & L timber retaining wall PROPSED RESIDENCE WILL BE TIED INTO IIF LLP-0 51206110 PUBLIC WATER SUPPLIED BY S.C.W.A. Uj Fis -6,I conc. block wall z I" T1rFE11K11 COPPER , �S i j$\I \ —0) RATER LINE FROM ti THE LOCATIONS OF WELLS AND CESSPOOLS 0 e SHOWN HEREON ARE FROM FIELD z S.C.N.A. VAULT 7 9 OBSERVATIONS AND OR DATA OBTAINED 0 Shed 0 FROM OTHERS + > D 9'1 0 LOCATION MAP . . A z REE W z W V'�.,.. � � D \ I 11 i '.. � — � \ ... � . ' r '� r ' + 10.01 lw z 0 LOCATION OF rzXlEil 4 lo. Q EXISTING HOU5E TO YeLL 52 BE DEMOL15HED ADANDONIED bFJ Uj 6,ZZ V 5) - 1: f� ---------- A 1-0 titt 010 )LI c LOCATION OF EXISTING awl U 5.C.N.A. VAULT A, I uj 0 Z <1 CID PA514EP LINE INDICATE5 ive aspert +, I' ", I 10.01 1 5 a 7 EX15TN6 ONELLINr —EX15TIN(5 TIMBEf� )'P MASONDFM' ",�UTCHOGUE,NY,: RETAINING AALL At�.ON , n f+ r t '• t u. ' '1 U I ' � l`(1'1 \ \ \ \ �uw..n.u.a...d--a•: •.e.. .,w-.-. ' EX TE57-HOIF_ 10.0 Lb415TN5 5EI-71C ad z- 5`f'57EM (TO BE + REMOVED) 15TIN6, DRI A E 100 TO 515 "REMOVED ------ p COVERED T j� — — � / / W , 4---- , " 0 _j 2 TEST HOLE By MIPONALO ra wire f4nc 7 timber retaining wall TES HOLE DATA 2/ 28 o2 GRADE E + B.Oft. UJ, N0605 qi� c LIJ . 0 _-7777 - RIF05Eb BLUE57ONr= = A EXISTING PROPERTY LINE 1.0 FT DARK 5WKN SANDY LOAM OL \ks) J 25 FT 51 LOAMY SAND SM 5EP71C, 5Y5TEM (1) 1000 GAL SEPTIC TANK Land now or formerly of: 61 FT PALE BROWN FINE TO MEDIUM SAND Sir (5) 5 FT, HIGH X 8 FT. DIA Jane Sweeney LEACHING FOOL5 SERVED BY KA7M IN PALS DROM FINE To mEviuH SAND SP wf (2) 5 FT, HI&H X 8 FT PIA. PUBLIC WATER FLOOD On1kc-7 EXPANSION POOLS APTEI #'46" COMP WITH CH ERED DAMAGE OREVE aION OLD TOWN CC )I— vp 0. 44 6 NATER ENCOUNTERED AT 6.1 FT. 5i SURFACE ti "vIVIE ANTI-SCALD Ali PLUMBING I K PREVENTING ALL PLUNGING WASTE -6(K & WATER LINES VAVICES AS TO PART. 902 EE 51JILI:� IN6 ^ALL S NEED N.Y. STATE BUILDING CODE* TESTING BEFORE COVERING PROJECT NO: cppper tubing is used PLUMBER CERT/Fl C IT/0) F 2105 PROPOSED GRADE LINE ELEVATION ± 9. 5 r-fOr.water distributing ON LEAD CONTENT I EFO) ERAWN BY: system; piping shall be CERTIFICATE OF OCC RJB� I ' �,IX, 2 ' MAX of types K or L only IpAh i�ECKED BY: UNDERWRITERS CERTIFICATE SOLDER USED IN V ATEI UIRED SUPPLY SYS TEM C.4 NNO DATE: EXCEED 2110 of 1. ' EA L 6119102 L)C�6 i SCALE; 1/47FT. 1/4 T. PROVID OPENINGS FGR rzt�j P�+ 7-'a. �� I V = 20'.0" ERG NCY ESCAPE AS APPROVED AS NOTED SHEET TITLE: QUIRE BY PART. 714 OF DATE L4q4;, A B.R#_,j;L88'J Ll— SEFTIC, LEAr-,HIN(A STAT BUILDING CODE. FEE: 130.2.�OBy:_2_c!n�& TAN< FOOL NOTIFY BUILDING DEPARTMEN' AT DO NOP 765-1802 9 AM TO 4 PM FOR HE ROCEED WITH IE. +8.5' FOLLOWING INSPECTIONS: PU MING UNTIL SURVEY - IED SITE PLAN FOR POURED CONCRETE IIF FOUNDATION LOCATION 1. FOUNDATION TWO REQUI 13 AAS BE I ROUGH - FRAMING & PLUME NG IN APPROVED. & INSULATION 5.0 ft. 114.0 ft.. W 4. FINAL - CONSTRUCTION M IST PROVIDE SMOKE-DL G ELI VATS HEAT BECOM VICES, COMPLETE FOR C.O. HEATING NCES 18"AS ALL CONSTRUCTION SHALL M ET SITE PLAN 61;ZOUNL'.) WATER EL. 13 FT., __171 PART. REQUIRED BY PART. THE REQUInEINIENTS OF THE Ly RUCTION & EN W Z W N.Y.S BUILDING CODE STATE CONST GY SCALE: 1" 20'-0" CODF3. NOT RESPONSIBLE OR 1) OF STATE BUILDING CODE.D-SI" CONSTRUCTION RS SEPTIC PROFILE PR(P1111 firl OCCUPANCY'0 N.T.S. USE IS UNLAWF L PAVi 7Q .% �; j by WITHOUT CERTIFI TE .......... r. qx BO'-10" ELECTRIDA LEGEND 10'- 4" - SURFACE MOUNTED CEILING FIXTURE I I c W � 4' �a I i m If It-LED AND... I. v 8 I •. ' � ' , '. . � � OMPAGTED. O uj o . / � N` •.Vy I / - -r- o W -rycl 5x16" vENr I .; 1 I' '• I ;. , --- 4 --------------------------- 5X16" VENT < , I ------------- --1 ' -- 1 L I I Q BEAM POCKET II � BEAM POG _�-�ry _-- M POCKET I 1 LEDGE BEA I .� '" "' ., . ,' �\ - TJI/ CONTINUOUS N I FILLED AND , I v \ I G S�AG� m I i m 16 O.G. / 'I i I T { COMPACTED.7 , . I ir e y uj 10'"10 5' O' 9'_B:: r— _ 1 --J O O L-- 1 1 I r 1 — I —_� 1 r•_ __ CONCRETE BLOCK I I •Ip 7 1.�. I\,ryPIEWRtS TO FRAMING Q i I j m 1 _ :,.I . BEAM POCKET \ I i \ U m I _ I I 1 L _ \ — —_ 2' CONCRETE RAT SLAB _ I I I•' I Z LEDGE WALL \ m L_ J I I 5-I/2" XII-V8' ANTHONY 5-1/2" X II-"VB" A ONY 1 I O BXIb" VENT _ _ _ O I POWER BE OR ABX24 POWER BE P1M OR X24—> \ i \ B' I II-,/b" TJ1350 GONTINUOIY \ /' 1 ,1 •I„' I n '^ REINFORCED CONCRETE v FOOTING FT. THICK W z V k 1 N I I 1 11 3 FT. X 3 FT. X 16"POURED II-,/B" TJI/ 350 PROVIDE WEB m I STIFFENERS AT ALLCONCRETE FOOTING. W/5 •5 m O . I Z 'I I .Gr — _� Q 1 11 I I BEARING POINTS REBAR EACH WAY SET 4” I 1 2'-9"I ! I uj V 5" POURED CONCRETE WALL I ( (P.) Q i OFF BOTTOM OF FOOTINb 5XIb" VENT (1YP) m I I 5, m I - 1 IL_ I 4" THICK REINFORCED L_ __J -1— I I y „ J CONCRETE 5I.-ABA6 i—_ — CRAWL 5PAGE �,;� I /Ib'-3" - AGGE55W/ WOOD --T— I _ �lpACE '�r'� 1 e DOOR I _ \ Q �I I `. -- I 5-1/2" X II-,/B" AN H NY 5-I/2" XII-T/8" ANTHONY I I m X11 I `� I •. I7- I I I I I POWER BEAM OR W1 4 POWER BEAM OR W8X24 \ I L—� -� 3' I I SET FOOTING DIRECTLY 1 8X16" VENT Q I BEAM POCKET I I m I I BEAM POCKET 1 BELOW P05T ABOVE BEAM POCKET r --- ___—__ i '.e IL --------- ---- -_________ ' LEDGE WALL I p of Z. ________,--_ r I 1 _ ---- y v1 I I - ,/ m I I r -------_ —— 1 I ,: ,:r I J �, S �1 m ! I ` 17 L_ J ,'. I REINFORCED 11 j j t I f UJ J• i T 2 I 1 I LFiLL,ED AND '1 a I x a b" ABOVE I I m I I L'c21urPAUT'Et3 { I W• s W CONCRETE FOOTINGS FOR I I I + I 6ARA&E 5LA6 It WOOD DECK ABOVE i ( I I I ON C.OMPAGTED i I 1 ' 1 W, w I m 1 1 FILL I m rY BEAWI POCKET 1 1 t I Gam— I I _ I _— ---- - ry y - L __� __ T_It-,v___------ _{ ____ _ _, I m I _ i L _ r _ ' f J I ry I . . ----------- 1 STEP DOWN I I R1 15: 3 , 6. . . I " I I • • -- { m I I 4 II I ED I I II :LT ED AREA F U DATION PLA PROJECT NO: SCA E: 1/a.• _ •0,• 2105 o RJB 1 O I I _-:— 14" THICK REINFORCED CONCRETE SLAB AT I I { 6 / 19 / 02 I { I SHEET TITLE: as ilr � : I 1 I FOUNDATION .... ," I ,.:,., � " L —'� 1 PLAN SHEET NO: � •". - " ____ 25-10" - -- Ib'-O" . _ ., , ,,, ,.,. . r _, .. ,r< . . r � . '.... �v.. - .. R1 , r . . . . .. r .T w 'A" , "FY�a7^.. c rii• '!o. -`i .5- - �i „r M ""'p, -. n rte, .. ,. " .,.. .:, . „- x"r ,�: : '1 . +w rc�'~�'.�,�r.tl�. ., TR4 exp. r r, �.... .I 1 1. t +�'.r .»:' '/1 s5 r1 ',.r r !i;' I • � r r 5, ['r � ' :, 16-2" 8'-2•+$” 446" 9'-Rd's" 15r_2�� 1T-O" 10'-0" az -,rr -� ' • - 1B'-10'• ,r D g 61+ 2-5" 2'-B" - - Y PA VINE O E3WEs O! 611 G611GI `fE SLAB WOOD ( Z t Tom„ �. P05T{/Q r JACK POSTS Y (4) O n • ', - ! POSTT O - -- --- IV is 00 ON (8) 1-3/4'X II-T/6" LVL 0- • ABOVE DOOR MCC" —(4) 2X6 Q EN I lb D A ON K V ' ItZ` - I I m CASED OPENING I I POST MASONRY Q �, - III FIREPLACE W 9'- " - I STONE HEARTH Q W .0 a ' ' ter , O 6:: (FLUSH) w. m n — COININGT MASONRY FIREPLACEYVWOOD Iy t O OOMIII In LIVING - FRAMED FJVGLOSURE OmM) 2X10 /'"I i - _ ?. 1 - 7Y10 STORSPACE I _ (41 LVL �� _ - MOO _ r (4) 2%6 S rl.I _ T FLOOR i N cv POST C SID": • «i�` (5) 1-•5/4'X16' LVL I Z e �- I „ "`)mi r . RA° r't'- �' - GONTIN10Us, OR 5v X 16 ANTHONY POWER —`�GAStD OPENING BEAM I (4) 2X6 POST W 0 N WOOD ��// O CASED _ T(S) LVL LL �1.�1(�� >_ _ - - - - - _ O• Z �I V FAMIL x V ui ROOM 1.1-T/B' f 10 6 WOOD 4-/2•" II' 10" -q' m I (4 2X6 • 16' O.G. O FLOOR LINE OF BRIDGE ABOVE POST I _ (4) 2X6 L _ POST - BUILT-IN SHELVES BUILT-IN 9H9.VE5 Aeove v Cr T CLOSET I I 1 r i- _ _ 1111k1" '�rri q � - � . ,Q �� T II - _ ,.,1• n�`"e r,�lr WOOD STAIR VV w'I Z • M _ i II 12 _�_ o MAY sTRINGE-R ! WOOD m ¢• 14 II CHIMNEY m RAIL 2p o ORO (4) J o ¢ IRS 12 CRT. CMAR �1( VL r� a o e i� r I SID/ ON 294 GGA. •/ + 4' !•Yi— - ~ 1Q T SSL/ I -o W J R MEG NIGAL - RE1 aRG ^r l' 0 ENGLOSUtE 4' BS2.QM PREFAB ARCH. Z, ' I GONG 0 m n • INC lSAP00« SAFE "0 Lu. < r = Y AD 111 5/6' GYP. BOARD _ _..- CAPACITY. PROVIDE - '4X4 POST 2XD B9YH BY OYftlER 119 STAI CKALLS E LILT IN6A� — 7— 1 11 BOTTOM ANCHORS TOP i Q H• v (B) 2%6 POSTS RILL HEIGHT U) �- „ BLI,ESTONE TREADS r ' J�" TYPB "%• bYP. HAND RAIL _ MAHOGANY OM-KING ON - ARD ALL a te' •"' GGA. 2X6 FRAMING SURFACES /,) .J iV _ LAUNDRY SINK Q"- VV - VV WASTE RJMPo�..r° C• 'E1yG r' ' TJ 550 O • 16' O.G, Vo DOOR 9' WIDE X H' HIGH - - ` EXTERIOR WALLS W/ SPANGLE FINISH NEW ' I I DOORS U l/ T °_ _ (5) I-s/4'X11-V6• LVL - .- _ _m F ' S ■ O R P PROJECT NO: coNrlNuaus GARAGE SCAL 1/4" = 1'-0' DRAWN BY: 2105 -- --------- ' Q --1 REINFORCED RJB I GONGRETE SLAB CHECKED BY* A; 0 6 / 19 /02 114" = 1'-0" SHEET TITLE: � I .• - -0 _-____- - - _� (0) 1-5/4-44' _ - - - _ —— — — —— _ � FIRST FLOOR - -_ - - - - - n PLAN o enTORAEaE 4 0AFZE6 SHEET NO: e B B 3 ,. 5,-s„ '1 F rS t W 0 tlFM B'_3-j'4" - 9'_O" 1all 10._I.. �^ WC ryry a` � 0 8 P O Sr, ry I - _ Z z FURL N LLJ 1 — 7 4%Ip R.R. I I (5) 2x10 (2) 2XIp R.R. _ 51 2x5 1 - G BED ROOM #2 I — Lu a Ib" O.G. .• • Ib" O.G. f, p , (5) 2X10 RR. !`f L BED ROOM #3 C °� 4 Z _ I OPEN T0 —� BED QLD ROOM— — — — FpD RRO S O _ „' • - -_- ---ry- - - - i � � ° GEI INb HEIGHT SHELF I THIS OM c it 2X5 G.J. ® �. O m O.O. 1211 UO I MASONRY GNIMNEY. _ W o- O _ 2X10 Ill i _ 2X12 RIDGE I I z ,e 213 --_ - = in 210 _ -- -_ 10, CASED OPENING A/ BED ROOM #Lf 4A` LE i 9HEL O O POLE 1 SHELF .� m \� - POST - - - \ O 4'-5" 4'-2" 2'-b' 4' f5) 2X10 FLUSH G.J. AT % ✓1 CABINET �itl r'� 2j2 RIO�E _ -� O I wpov cnBINET I m an D . 1:� l� I 2I S_2 RAILING 2014,_ , �� yh �. O "'I I 5' " LLPOCKET DOOR W001P FLOOR CASED OPENING LINE OF 8'-O" GE'ILINb tF (6) IXIO WRLIN BELOW WOOD , i< SHELF t - A yI STAIR 6 r +•� _ __ - I POLE Y o RAILIW6 ON b II I CLOSET/ III ! QR 4 TIE i I ry - 2xa Z• L • Ib � P •- >p; i l5yre dl ` i POST en'`6,i 5 VES — �,9 w'A/ $ J 'f m x w � -., yl _ \ -_ - __ _ IN OR Y ry POLE �. • 4 W• g w I SHELF 4 Lu ':I mia gW• o TORA m 5 - -- - - 21 �_—�-E- N m 4-In" I ("�1 2xlo NVl2) v2"xq" srL. PL �. u 9 up — B -- - - -- — - 1 f� to 2xb PpsT V hXI2BR 2XIp RR. I III ; [D 9' s Ib" III %IO O.J. ® Ib" O.G. 2XIp R.R. I II 11 6X16' - S CON F LO R LA OJECT e O.G. 7 D =o NO: o UNFI I5HED B m 2105 m DRAWN BY: AT G SCALE: 114" = 1'-0" — RJB CHECKED BY: O z 5/14" PLYWOOD SUSFLOR 1 XIZ l'i - 6119 / 02 b x I ry d (V n SCALE:1/4",= ,°.0". SHEET TITLE: QIP m I III I �' b � I y Iil SECONDPLAN LAN SHEET NO: BELOw • 1 21120-9 2"T hr t6fp egre ' � t at`Pyy�?3firMi +, '�' tiC`Mda TPfi ' " �Z ,� iy/. SMa7 r� it'S, t t - - NO RAKE OVERHANG. 1X4 ON D IX8 N/ IXIO FRIEZE PROVIDE CRICKET THIS B AREA Ixa oN Ire FA IA AT - __"-- MA50NRY CHIMNEY SHINGLES ALL PROVIDE LEAD FLASHING E VALLEYSAND WOVEN - - MASONRY CHIMNEY C PROVIDE FLASHING AT ALL COUNTER FLASHING (TYPJ �i r ,I I B , _ _ - - .._. _- RAKE OVERHANG IX4 -- , -_ . . - - _.. _.. - - -_ - - _ _ - .-.. ON 1X8 AlIXIO FRIEZE _ _ J ASPHALT SHINGLES ON . "ICE 4 WATER - - - - BARRIER" ON 50M BLDG: PAPER ON 5/0 PLYWOOD DECKING ON - _ - - - - - - - - - - - ' - '-- - - - - - - - - - - - - - --- - -- .__ E CRICKET THIS 4X10 ROOF RAFTER - - - - - - - _ - -- - _- - . -- ` - - - .' -- - -- - -- - _ - - - -_ AREA W O / \ PROVID LG-C FLASHING-CtYP:r _ - - � EDAR SHINGLES- --- - �� '- - — - -- -- - - - - -- - - _ SECOND FLOOR CEILING I- _ _ r -- __ _ _ - _ _ _ - -.-_-- IX4 ON IXB FA5GIA - - - _..� 2B- - -_ - 0 _ _ - TOP OF WINDOWS - - - - /4' - -""` PROVIDE STEP FLASHING LLJ ._� ._ _. _ -_ _ .` -_ O _ __ _- - THI5 AREA 0 _.. — — - --- — PROVIDE METAL DRIPGAP - - _ - . _ __- - - _- - - `OR17P.M€NTAL PFTTERN _. _ _ - - N 4 � „ (TYp) _- - _ _� -- _ _ - _-_- - "._ _ _ -_ - _ __. _. _. _ IX4 O I XIO FASCIA Q ASPHALT � - -, _ - - - - - -SECOND FLOOR - Kb F'REIZE BOARD .- - _- -ROOF - - a I; K4 ON IX8 FASCIA - - -- - _ - - -_ - - ASPHALT SHINGLE _ _ __-- - -" _ - — - - _ FIRST FLOOR CEILING I: _. _ - - - _ -- --- - - - - __ ___ _ X40N..IXIO FASCIA __ _ - .__ - _ _ _TOP OF WINDOWS XUJ 5/4 X 4 WINDOW GA5ED BUILT-UP BEAM WOOD CASED BEAM_ OA6IN6 (TYP) - - --- - -- - _-f-7_ - - - -_ - - -�._GEDAR 5HINGLE5 _ _ — - O Q CUSTOM WOOD SHJTTERS - - - .. ._ - - _ _ O CEDAR: SHINGLE 5HOWER -- O - - - - ---- - '- - - - -- - - - - - - -- - STRUCTURAL COLUMNS. PROVIDE ENCLOSURE - -- - - -- --- - - - - '- - - - ANCHOR STRAPS TOP 6 BOTTOM 0 WOOD RAILING— - . . - - -- - - - _ --_ - __ - - _ - CASEDWOOD Li E D a POST - - _- - - - -_ - _ .. - -__ _ _ _ _ _FIRST FLOOR - 'RENDERED CONCRETE FOUNDATION n, -- --- - RENDERED CONCRETETYPJ O 0 W Z I � � W C9 A/ O I TOP OF SLAB I I I I LI . r,----------- -------------- --�.------------- -------------------------------- T-------------- --------------I----_--------_--- - _ -- U _--_-__- L---------------------------- --L_-_ ___- ______-_-__-__--_ -------------- ---- --- ------- -_______-_------- ------------------------------- L WOOD LATTICE NORTH E L E VAT I O N " SCALE: 114" = 1'-0" D B PROVIDE L.C.G FLASHING THIS AREA RIDGE VENT (TYP) y Ii 2 RAKE OVERHANG. IX4 --_ _- - -_ ON IXB W/ IxlO FRIEZE MASONRY CHIMNEY - - - - _ - -- - - - --- -- - F WE 5 THI5 PORTIOM rc -_ _ -_ _- WOODNER 8 0 I ter_ O TO R W J 7=7 — — -- --_ - W . z PROVIDE FLASHING AND COUNTER _ a r U CASING (TYP,_ r ' Lu. o _ FLASHING AT ALL CHIMNEYS TnI 914CASIN VINDOW_- T�O\ \\\\\� _ - _-_ -_ METAL GAO(TYP) I- � NOTE 9'-O" GEILIN6 — - - 5 - - - _ -_`` - _ _-PROVIDE L.G.G FLASHING THIS - --� ___ - - _ - �' r L- _ % ~ IX9 ON IXb TO OF W NDOWS 11H HEIGHT MA5TER --- r - Ei:: BEDROOM DNI_"--r4 LINEAR CONTINUOUS _- _ i,1 - _ -_ i� - VENT FIE F�.OND FLO,Q13-_ _ _ _ _ - -- - -_ -- I __ _- _ - _ SECOND FLOOR- FIRST FLOOR CEILING - - - _ _ FIRST FLOQRSeEILlNG _ 70 OF wlNDOvis % .', P OJECT NO: -- - - - —_ - - r .. .. WOOD CASED BEAM 21 OS -_ - -_- © � I ` -- � RJB -" - - - - H [44 - REMOVABLE SCREEN PANELSI HLCKED BY: wlNDow Box WOOD CASED 4X4 COLUMNS PROVIDE m ANC aR STRAPS TOP AND Bo roM 6 / 19 / 02 STEP- �t.Fn LES _ ___ _ - _ _ _ BLUESTONE PAVERS E TREAD _ _ AR SHIN6 _ _ - AR 5HIN6L "" FIRST FLOOR — - - -STEP—"', TOP— — — - - SHEET TITLE:1 - - ' OF FOUNDATION O" t NORTH & Y A ----- ------- -----i -----_-----_- -- -TOP OF SLAB SOUTH 1------------------------------------ --------------- --------------4----------------- ---------- ----- ---r -------------------- --------------I ELEVATION HEADER HEIGHT THESE WINDOW5 '7'-b" SHEET NO: SOUTH ELEVATION 5 SCALE: 1/4" = 1'-0" ::, .rl. � ..-,.. , i ,, � :v�- �, ..� -� ,,,., - " � ., � , - � � : .; ' rfi, 3 ,.., cr:Y A . 7 p - LU Y - - O _ - _ - - - - - o - -" D -= -- D 1L�NL EIb..ELOQR_ _ - - W u _ h ToP1JF PI ATF ....,._ — _ _ _ - y HEADER HEI6HT T 'T^ Art Zuj0 ------- -- X -D L zm Y - - -- - - --- — h C� O � W V TOP - — -�_ __-__-___ _�1_-7L---r. , _-_-_-�r _______________________________ _____--______-_______- am U -_ _ ____J-__L___L---------------------L--------------------------------L-------------L__-__-___-__________-_- --_---___-__-_________- --J EAST ELEVATION SCALE: 1/4" = T-0" A 7 6 a7 z 7 MASONRY GHIMNEY MASONRY CHIMNEY '�-'--a--- r�i--•' W _J TnSPHALT ROOF _ - .-r_� _-- � W csi f w u WNSLew - W ' - - - --- - - - - - - - - - - -- - — -- - 79) to - _ SECOND FLOOR GEILIN6 -- - - - - �--- TOP OF WINDO - _ "- - -- -- — - SECOND FLOOR _ _ - - FIRST FLOOR GEILIN6 - -- - - - - - - - - - - - - - - = JECTNO: - I -- - �� - - - 1 - - - - - - - - - - - -R - RJB WINDOASCHECKED _—_ _ _ _ - - - - — -- - - -__ -- - - - - - - - ONLY - OD-SHIN6LE5 LL i THIS DIMENSION FOR , -- - O O - -- O rowER - 0 1 - - - - 6119 /02 114.. = 1._0.. -- - - -- - - - - - - - - -- - - — - - --- - - - -- -" FIRST FLOOR SHEET TITLE: - - - - ' . • • - - OF of FouNDArION� EAST & I I I I WEST __ _______ -- _ - L______---_--_-_-_I ----_-_-_-_- _ _ _ TOPaFSLAe = —T �F� ELEVATION FFP i-- _J SHEET NO " Q WEST ELEVATION SCALE: 1/4" = 1'-0" WY 0 Z Zz o - 1y-� r---�h- — Q MASONRY CHIMNEY W/ BRICK 3/4" PLYWOOD DECK -�-. - r FACING -I- �- - W -- ,- CONTINUOUS RIDGE VENT -'- -�- - -r --E--- h- 2XIN5L O.J W/ R-30Z --'—_i_ BATT INSULATION 2X8 G.J. A/R-30 1- �- '.-�� I_ —(3) 2X10 PURLIN � O BATT INSULATION -I - i--�- L G _-ij + _ (3) 2X10 Al (2) I/2" X 9" STL PL PROVIDE 2X4 O ON GEILNS OJ5T. OVER `` -++ - 2X10 RAFTERS AT DORMER DORMERS / —I- t- - h— �i r I O --- SECOND FLR. GEILINS _ 5 TOP OF PLATE /W 0 O 12V I _O„ rY � � F,, V IA5TE ° UNF I N I SHED @ATH " ATTIC� I � R - 0 0 12 eATT IN3uLAnON FLARE ROOF FRAMING 16-1 2° O STEP / CX_X-3 CXX) CXJ(.7 CXX� CXXS WICXXS — o L 06 Z. 7y L%Fy En I I I ❑ R-30 BATT INSULATION TOP Or PLATE 2• _ CONTINUOUS VENT I I I W J• w I 2X6 0 I6" STUD t z FRAMING A/ R-Iq BATT INSULATION Al [I El = w I I ENTRY POAD'ER 5/5" EXTERIOR W' FOYER BATH PLYWOOD 5HEATHINS= ❑ I I I I A/ WOOD SHIN6LE a a ~ _ FINISH Q y to• OVERHEAD SARA6E DOOR O SYP. BD BLUES70NE PAVING ON 4" I I- - -- - I ( FINISH: THICK CONCRETE SLAB -h - - I I -- R-19 BATT INSULATION O I I I — — . �5t�� FIRST FLR -- -- - - 4" THICK REINFORCED ANCHOR BOLT AT 4'-O" �M�' 84.y CONCRETE SLAB. 17 TOP OF FOUNDATION // CRAWL SPACE N \i\\�/\\j\\j 2" RAT SLAB /\��� /�//\/// - . . - //// ..2105 / // // // // / TOP OF SLABy% 9 ; ,�- DRAWN BY: \\i\\��\\,.\\i\\\ - - - - - - - - - _ - - --- - - \/\\/ RJB \ - - - - - - - - - - - - - - - - - Y r75 �' �AL , / / - - - - - - - - - - - - - - - - - - CHECKED BY: © BUILDING SECTION "B" O BUILDING SECTION "A„ DATE: 6119102 SCALE: 318" =RO" 718n=.Ilan SCALE: SHEET TITLE: BUILDING SECTIONS SHEET NO: 7 1 , M,!l �l 1� ujw r , RIDGE VENT (TYP) O (2) 2X10 HEADER 2X12 RIDGE 2X8 RIDGE V/ wwi Z ASPHALT 5HIN61-ES ON 50# BUILDING PAPER 2X6 ® 16" r1' UJ ON ICE AND WATER BARRIER ON 5/8" V PLYWOOD ON 2X10" ROOF RAFTERS A5PHALT SHINGLES ON 80* BUILDING PAPER ON ICE AND WATER BARRIER ON 5/B" PLYWOOD ON 2X10" ROOF RAFTERS Q Q IX4 ON 1X8 FAGIA AT Q RAKE Q _ CEDAR LOUVERED W VENTmas Z i 4 HI. 2 U) O PS FOR 8 Z PROVIDE HURRICANE GLI 2X10 CEILING JOIST ® I6" W/ O I- 2 ALL ROOF RAFTER PLATE R-SO INSULATION CONNECTIONS r 2X4 NAILER / BUILT-UP WOOD IX4 ON IX8 FASCIA O 'Lu HEADER Z IX6 FRIEZE \ 1'-p" " 1 CEDAR SHINOLE5 5-1/2r' TO THE WOOD RAILING W WEATHER ON 50# BUILDING \ _ ' / - \ PAPER ON 5/8" EXT PLYWOOD - /vi / Oi \ FINISH \ \ LVL HEADER FU.. \ - FINISHo BEIM V PROVIDE 5TEEL JOIST #4 HANDERS / — \ WINDOW B6YDGE 1 3 12 / / \ / \ \\ m DININLG QII 2 NO.FIN_FLOOR O 29-I r r ROa?M 7F III OP OEPLA — � II' --- — — BUILT-UP WOOD HEADER .. I MANTLE BY OWNER / GYP. ED' . ' WOOD SLIDING DOOR -- -_ — W -J. 7 z AMIL FINISH bXb COLUMN CASED 3 W. CEDAR 5HIN6LE5 5-I/2" TO THE IN WOOD Y i WEATHER ON 50# BUILDING W r PAPER ON 5/6EXT I I I till 1 1 11111111111111111 ' a 5 PLYWOOD(TYP) R - \ BA \ / (0) U)• \ P VER — BLUE STONE A 5 PROVIDE DOWELING AT 2 FT --- O.G. FOR ALL SLAB TO lot 11 '— - 7 ST. FIN. FLOOR ----_ - FOUNDATION CONN 4 { � -- -- - - - ----- - ---- - - - - --- -. CXXJ lXX) CXX3CXX3U(XS TERRACE CKK) CX.XS OF F9SlNO - .--r--,T GIRDER . . ' 4 REINFOIQCED CONC. /\// / 'PRf�V137�.t7'OWE�.fNG AT P FT „SLAB \. \,(� /\/\ -RROV VE ANGIi BOLTS A��BR' ! 'S1-.A@ 70 Q r✓Op GONGRETIE BLOCK PIER5 //\/,�/\/ rwNv?tIaNCONN v . CRAWL SPACE v\\ X CRAWL 5FAGE \� \ \ 1 0 TOP Or 5 L A B — — — .,—. — — — — — /\/i�� - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -• - - - - - - - - - - PROdECT NO.: 2105 DRAWN BY: . C D RJB BUILDING SECTION 4 REINFORr INC BAR (T /P) CHECKED BY: SCALE; / " CONCRETE FOUNDATION C FOOTING BUILDING SECTION ��Dvv DATE:SCALE: 31/8"=1'-0" 6119102 SHEET 01AL"ro: BUILDING SECTIONS SHEET NO: I 10 /05 / oD - -- SITE DATA T 20021 SCTM # 1000-104-7-2 L PROPERTY: PENNY RESIDENCE ADRESS 570 MASON DRIVE CUTCHOGUE, NEW YORK SITE: 53,948 SQ. FT. = 1.2385 AC. Land now or formerly of: AREA Charles Boyer, Jr. ZONING: R-40 SERVED BY PUBLIC WATER FLOOD: X Y ZONE uj SURVEYOR: JOHN C, EHLERS 0 RIVERHEAD, NY. LICENSE # 50202 Lu F�00 ___ - DATED: 1-12-2000 (n W Cy - z ______ z W FSO Z07 \ \ \ Bulkhead _, \ O' O NOTES: FOR ELEVATIONS AND Oa \ @ 55,55 ,7�J � TOPOGRAPHIC CONTOURS REFER TO ~ Oh@ \8 EO BE FRAME DED condo. _ _ - - -1 — _ �'( 9 MAPS OF THE FIVE TOWNS.M.S.L. DATUM & RESULT C3 TOPOGRAPHIC Q Q Pa Q timber retaining wall PROPSED RESIDENCE WILL BE TIED INTO F� cont. block wall •t ! , , PUBLIC WATER SUPPLIED BY S.C.W.A. Z W Q I" TYPE"K" COPPER 7 , ' / O O) - _ 5 - "' SHOWN HEREON ARE FROM FWELLS IIELDESSPOOLS z Lu WATER LINE FROM —=�f tim er re . 7 ' - - UN, / ' i ' ' == \ �° + 1 I W 5.G.W.A. VAULT Fr. I� / g� * 1 \ o C� Shed 11 Shed �t 8 --�\ 7 `="' - 1 OBSERVATIONS AND OR DATA OBTAINED 0 \ k. �( \ FROM OTHERS 14 >1Q — LOCATION MAP z `''„, i + . Q � - "- -ar- ,� �' '`',; REE \ /'If / / /ii o � `'� W Lu V 1 VI/ 1290 LOGATION OF EXISTING r. I \ EXISTING HOUSE TO WELL TO BE $ \ \ '6 RAGE( NWFiOUSE �` \ BE DEMOLISHED 4 II W I Z * Y ry' _ V uj ABANDONED \ / SL B FIN FL a1,EV. "f N (DW EL r -k1 -O ' +L?y O"y I O2'-0 � LOCATION OF EXk5TIN6 1 6y� �c r— — + �m�, I "' \ i¢` , r'" V 5.G.W.A. VAULT � H/ <S �� I 10 01 � I � w I °o l \\ \\ 9 r. \\ exisEm rive / + - - - -I v �., ' DASHED LINE INDICATES 4 . 1 1 11 1 � � a I,rll 1 'Y 1 asphbe it pVed + + 10.0' 1 n ° EXISTING DWELLING �Q to 9 8 7 �-• 1 1 " `ENNYR \ - - - - - - I -- 6 \ `o EXISTING TIMBER �' 1 MUT OOON �EIiYr \. FX RETAINING WALL n 1 cn'i T - LZ74ATOION � � ( �4p ' ,, Ica Li �Q � r EXI5TNG 51 I 2�a v ? } RE TEM (TO BE f\\ \ x SYS 0.0 E MOVED) EXISTING DRIVEWA \ 10.01 5� ,, .Ni ♦ 0COVERED "O' ' y_ TEST HOLE En'TO BE REMOVED (�� _ ,,,. \ 20 -OI m _ ��'•n � � i � ;� " t 1 1 ' °(v T RR N ✓ C pi•. - W ' W 6E0sclE cE wire fdnc 4 7 \ timber retain in wall J ' W' 'I ` \, \ C�_\ TEST HOLE DATA ( 2/ .2b / 02 ) GRADE EL. + 8.Oft. W' a 8 O FT DARK BROWN SANDY LOAM OL ROPOSED BLUESTONE EXISTING PROPERTY LINE _ _ _ �6 " r'Y, DRI VWAY 25 FT BROWN LOAMY SAND SIM N y I 5EPTIG SYSTEM O Land now or former) of: 61FT PALE BROWN FINE TO MEDIUM SAND SP (IJ 1000 GAL 5EPTIG TANK y (5) 3 FT HIGH X 8 FT. DIA Jane Sweeney WATER IN PALE BROYPI f LEACHING POOLS SERVED BY FINE TO MEDIUM SAND SP IN/ (2) 3 FT. HIGH X 8 FT DIA. PUBLIC WATER EXPANSION POOL5 SEµµED y� ITo FT. G ylyG F� WATER ENCOUNTERED AT b'1 FT. BELOW SURFACE ~ i - BUILDING WALL P OJECT NO: PROPOSED GRADE LINE ELEVATION ± 9 . 5' FT. DRAWN BY: 2105 RJB �-1 IN., 2 MAX CHECKED BY: DATE: 6119 / 02 SCALE: 11. = 20'-0" SEF71G LEACHI , I6 SHEET TITLE: IE . +8 .5' fiNK IE.+'7 .bq ' ®OL SITE PLAN IE.+8.3q ' IE.+7.6 ' o z 5.0 ft. - 14.0 ft. in SITE PLAN.. GROUND WATER EL .3 FT. SHEET No.: SCALE: 1" : Zlo._oSEPTIC PROFILE 1 i N.T.5. I REVISED, 10 /05 / 02 5'-0" 5'_2-/x" 4'-6" 5'-2A" V-0" 10'_q" 2'_5" 1T'_O" 2'_5" 14'_T" 14'_5" 1 WIX y� ( b. V3: N D y ZZ (2) 2xl 8 - - - - - _- - - RLI (B) 2XIO O (2) 2XIO R.R. 2x8 G.J. LJ un a BED ROOM #-2 - — Lu t - -- - - ' — — — — — — — — — — Z — — i /1 (5) 2X10 RR X13" O.G. a16" OG. - - — - - - - - - - s0 -- BED ROOM #3 INA OPEN ToROOM WOODI O Q a; FLOOR I 1 ' _ _ d '�-" " POLE ! SHELF - POLE l SHEL ' THIS M I ' . - - - - - 9'-O" CEI IN6 HEIGHT I J0 16' 0.4 MASONRY CHIMNEY. W 2x10 PURLIN - _ L, - _ o' 2x12 RIDGE F AL m BED ROOM #4. 4-)5 _° LE < SHEL Itl 210 O - =POLE SHELF — — — — — _ — — _ — -- - IGA5ED OPENIN6 I O T 1 11 2112 2,"; Q _ 2X12 RIDGE - 4'-B" 4'-2" 2'-a" 4' " (PS�jXIO FLUSH W/�.J. AT O BUILT-IN 6 q_2 % "CA811INET1,11,D 1 I 5' 2" ' BRIDGE wooD O1L �" waovRAILINGS, POCKET DOOR PLOORGA5ED OPENING DN LINE OF 8'-0" CEILING 2X10 PURLIN m 215 DN . . $ u OPEN BELOW '± III 11 1 ml i, 5TAIR Dt "HELP 3-* .n.n;, ay •D „yv, '- , RAILING POLE _ < DN a" III CLOSET/ QL2X8 H e © • Ib" II �B °d ¢• 00 P05r K _ -- - . _ - gg N Y�f ,r_+ • IN FLOW r0 TTIG r x - W J• OR o TIUP- 216 1 POLE I j . IIIW• e 21 STORAGE m m M w• ` cl g K 4-1/2" (5) 2x10 N(2) v2rxq" 5TL P e III i 1 I I I 3 2Xa X05r i I I I 1 i I Q2X10 R.R r N s 1t5" O.G 616" 0.6 1 " � PI 'h• I I Il ' v I 1 I � � ��y'SGRED A5t fY 2x O G.J. e la" O.G. I K � 2x10 R.R. X 2X10 .R. �� 7B3tl0 / Y D G. w e OG o SECOND LO R PLAN Ho m UNFI SED mPROJECT NO: AT I f7 IG D SCALE: 1/4" = 1'-0" RAWN BY: 2105 - RJB HLCKED By: L Oz 5/4" PLYWOOD SUBFLO I O�i n III rXi ry n 6 / 19 / 02 � I - n j u4 ry SCALE:1/4" = 1'-0" , m a ^ 11 a I THE TET TITLE: l l SECOND FLOOR P II LAN -- LOWS SHEET NO: 5'-O" b'-0" 5'-0" 2'-Y' I I REVISED: 10 / 03 / 03 A LU - - — _ _ _ y - - - - - - - _- _ -- _ -- _ cn Zz FFF Yy FIN FLOOR— _ --' — -- — ---- -- --- -- J - HEADER HEI6H7 F ' .- _ ---- �F- i1 i- i_ O o _ II 1 Q 00 0 � J Lj _ W O W 1 Y._ TOP OF S�A�— _L_ _ _ D Ell ----- - - -- - -- – - -- - ------------------------------------------------------- --------- -------- -- ---------- ---- - ---- --------- EAST i _ __L _____________—__--_L____--_--_---_—_ EAST ELEVATION SCALE: 1/4" = 1'-0" A H q1 2 7 MASONRY CHIMNEY MASONRY CHIMNEY AT.aPHAL7 RGOH y — _ SECOND FLOOR GEILINb -- - - -' TOP OF Al m 46 D � m - - - - - - - - -- -- -�- --- � -- - SECOND FLOOR EWAC FIRST FLOOR GEILIN6 _ PROJECT NOZ 105 DRAWN BY: T- FEM EI RJB TOWER_ - - — — - WINDOWS R ONLY Q I 6 / 19 / 02 — — -- - - - - - — - -- -- FIRST FLOOR SHEET TITLE: I - - " ' r EAST O I I I I I « z I I I I I WEST F`------------------------------- ---- �_------------- - ------_ - -- _ TOP .oF_SLAa = -- �F� ELEVATION L_______________________________ _-_-___________ --_J-__--__--__--_ SHEET NO: WEST ELEVATION SCALE: 1/4" = 1'-0"