Loading...
HomeMy WebLinkAbout31185-Z FORM NO. 4 TOWN OF SOUTHOLD BUILDING DEPARTMENT Office of the Building Inspector Town Hall Southold, N.Y. CERTIFICATE OF OCCUPANCY No: Z-31161 Date: 09/14/05 THIS CERTIFIES that the building ADDITION Location of Property: 55 SUMMIT LA EAST MARION (HOUSE NO. ) (STREET) (HAMLET) County Tax Map No. 473889 Section 38 Block 7 Lot 10.14 Subdivision Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated JUNE 3, 2005 pursuant to which Building Permit No. 31185-Z dated JUNE 6, 2005 was issued, and conforms to all of the requirements of the applicable Provisions of the law. The occupancy for which this certificate is issued is DECK ADDITION TO EXISTING SINGLE FAMILY DWELLING AS APPLIED FOR. The certificate is issued to ALEXANDRA JONES (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL, N/A ELECTRICAL CERTIFICATE NO. N/A PLUMBERS CERTIFICATION DATED N/A t�riz Sig ture Rev. 1/81 FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 31185 Z Date JUNE 6, 2005 Permission is hereby granted to: GUSMAR (A. JONES) 36 BLACKSMITH CT. HUNTINGTON STATION,NY 11746 for CONSTRUCTION OF A DECK ADDITION TO AN EXISTING SINGLE FAMILY DWELLING AS APPLIED FOR at premises located at 55 SUMMIT LA EAST MARION County Tax Map No. 473889 Section 038 Block 0007 Lot No. 010 . 014 pursuant to application dated JUNE 3 , 2005 and approved by the Building Inspector to expire on DECEMBER 6 , 2006 . Fee $ 150 . 00 Yom Authorized Signature ORIGINAL Rev. 5/8/02 765-1802 BUILDING DEPT. INSPECTION [ ] FOUNDATION 1 ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INS ATION [ ] FRAMING [ FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION REMARKS: d DATE 7/" INSPECTOR 3a ps e, 765.1802 BUILDING DEPT. INSPECTION [ ] FOUNDATION 1 ST [ ] ROUGH PLBG. [ ]=RAMING ATION 2ND [ ] INSULATION [ [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION REMARKS: DATE Ill INSPECTOR `' FIELD INSPECTION REPORT DATE COMMENTS FOUNDATION(1ST) J� 3 -------------------------------- i� c FOUNDATION(2ND) m Z ROUGH FRAMING& �3 PLUMBING 3 _3. r INSULATION PER N.Y. 3 STATE ENERGY CODE 9\ O V� 3 FINAL r P. ADDITIONAL COMMENTS p i O z m N ft' rg R L � :t> � v TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPAJRTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD,'NY 11971 4 sets of Building Plans TEL: (631) 765-1802 Planning Board approval FAX: (631) 765-9502 Survey www. northfork.net/Southold/ PERMIT NO. Check _ Septic Form NX.S.D.E.C. Trustees Examined, 20� Contact: Approved {a 20 49% Mail t . 4c Disapproved a/c v v Phone: Expiration 1 41020"0 ,t Building Inspector APPLICATION FOR BUILDING PERMIT Date 20 INSTRUCTIONS V-a—ktnapplication MUST be completely tilled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale. Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e. No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize, in writing, the extension of the permit for an addition six months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York, and other applicable Laws,Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws, ordinances, building code,housing co e,and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. (Signature o applicant or Dr/elf acorporation) 36 bE1-eel m a e5cxU T- (Mailin$address pplicant V/V r inlcro.J �. /y//7)�. State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder Name of owner of premises !7(. C&PJ[Q `J 010—PS (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. Plumbers License No. Electricians License No. Other Trade's License No. 1. Location of land on which proposed work will be done: n ,1 s� S'u corn I L--#9 Ne )FAST M?ri and House Number Street Hamlet �7 3 nvwli ..n County Tax Map Dlo. 1000 Section p Block 4 . Subdivision Um yYl t T STATteS Filed Map No. (Name) 2. State existing use and occupancy of premised and intended usupanc of proposed construction: a. Existing use and occupancy ��, nocc i r L P r L H SS/Dtn( b. Intended use and occupancy 3. Nature of work (check which applicable): New Building Addition Alteration Repair Removal Demolition Other Work :7K (Description) 4. Estimated Cost ��o a Fee (To be paid on filing this application) 5. If dwelling, number of dwelling units Number of dwelling units on each floor If garage, number of cars 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front Rear Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories S. Dimensions of entire new construction: Front Rear Depth Height Number of Stories 9. Size of lot: Front Rear Depth � 10. Date of Purchase 0 pt Name of Former Owner (n u5 yy�c+i' 11. Zone or use district in which premises are situated PS /Gt 12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO 13. Will lot be re-graded? YES NOY—Will excess fill be removed from premises? YES NOx- 14. Names of Owner of premises karpH bf a1 &Vdd dress Phone No. 7382z' Name of Architect Xohe&r fits AddressSVHi Name of Contractor 0 Address Phone No. 4 7-?-8' 7')o JNT 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO Y_ * IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. STATE OF NEW YORK) COUNTY O being duly swom, deposes and says that (s)he is the applicant (NaAteoflindividual signing contract) above named, (S)He is the d W AI.Q C (Contractor, Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application: that all statements contained in this application are true to the best of his knowledge and belief, and that the work will be performed in the manner set forth in the application filed therewith. Sw to before met s 15rn day ofQJn2 20 � 1 Not _jIublic Signature Applicant BMIEI.DDR " Notary Pebtk,3tete 01 NenVA No.01D06095321,Suftdk Term Expfr )*7.20 D SURVEY OF LOT 26 NAP OF SUMMIT ESTATES SECTION No. 3 • 6, FILE No. 10769 FRED MAY 21, 2002 O� oo s SITUATED AT EAST MARION �1►"eg� + , �s•'° �ij \ TOWN OF SOUTHOLD �5,9` '` '� V SUFFOLK COUNTY, NEW YORK r mac+ S.C. TAX No. 1000-38-07-10.14 00 SCALE 1"=40' SEPTEMBER 28, 2004 J ° AREA c 30,117.20 !q. ft. 0.691 ac. N S Naas Ole t1ini�am alpmsm AN An 10.rM 4? 4 g9• z Nam To no ry MR vm mu DAM LOT © } �. 3. IINN NU�m�A:t ,�. MUSE a (AN GMAD s. fi�j�dR 4� a /pig AIM I MINNOW �SWUM FOR . emlmMM M o Soo .. n VKWr Aw. � d 7YY _77 lry°` ®rwoem vr,.Re POR t� * R O :Y ®AAa01VIC 1AIY -! g Ory 0 THE LIGATION 6 'WELLS MIO �9y 005MAROO NWM OATH OOT Soft ME: NEOM RCD -10 `4C O` ,jWT Y � \ P147iN�M A6GVIpYQ mm CJ' ft THEE pm All Fon L.vo .pZ K c p q* / LY •° IO F/q 'Y 61Wd�101 � FAMJOaM IJNI. 111E Mal N!A(SFAR" VELA aSLl6trp11S T�OOI0 / ',n A. tVegno ro°II�RIa�sA°vl�olgvwc4n a °°sW�aN� ` Y Surveyor Mum tl 00 N�NNpp1N �4LP��'r / O Lr He RRRY TOM _— �FRo YNO 3-1 - SIIRMbM - JFM Ras - w.rwuciiori :�iwt "Itim. coNlnval9s w Wr YApI�arff�. PHONE (937)727-2090 Fax (631)727-1727 THE UUNTENCE OF COPY 9N` 190311" . w1iGR cAarcMrs a xaoRa v 6NPtiP3 tIG1FD AY - .w 1111001111 A094S6 ANT. HOF 91fw11 YR: "GF Q;dAAMS£FP. J22 ROMIOAE AM" P.O. a. Ml '�• N*m yy l'O^I IGvr,lwtl. Nq YWF11 11901-0 _ DECJKIN Taco each TYPICAL Joist to girder FLOOR SYSTEM 4x4 or 6x6 POST 0 Simpson Galvanized —r 36" high railing *' post to Concrete to code LU connector ABU44 Strap or equal. anchoredpost tnto 12" concrete pier2X10 DECK JOISTS- with TyO2 x 10 Treated Nailer Board / Strap Lag Bolted to framing with./ In eacU 1/2" diameter galvanized DOWN Q bolts at 24" on center TO staggered taco at each ,foist. GRADE 6 -O" 18 -O" 6 -O" ~ AS REQUIRED TYPICAL STRAPPING FDR DECK PLAN DECK CONSTRUCTION SCALE: 1/8° ALL LUMBER: SOUTHERN YELLOW PINE: Fe '350, E:1.4, BASED ON TABLE 4B FROM Typical Nailer THE 1995 HIGH WIND EDITION OF THE APPROVED AS NOTED metal flashdng abutting the concrete. WFCM MANUAL. _ DATE:_ �--�- --"----------.....-'---------'................ - ---------------.__....___..--- ALL FASTENERS SHALL BE GALVANIZED FEE: D _ BY: - - - NOT BUILgJNG DEPARTMENT AT - Q 0 765-18G2 8ANI l:i PM FOR THE Lu Bi LU FOLLOWING INSPECTIONS: ~ 1. FOUNDATION - TWO REQUIRED 1 Q m 36" HIGH RAILING FOR POURED CONCRETEN Z 2. ROUGH - FRAMING 8 PLUMBING O Q 1 3. INSULATION p Q -� -4 w 4. FINAL - CONSTRUCTION MUST 4 0 Q JL BE COMPLETE FOR C.O. , ,,, ,,, ,,, o? ,,, ,,,,,, y_ „ ... ... ,�_ „ ... ... 2x10 treated ALL CONSTRUCTION SHALL MEET THE - ,Joists REQUIREMENTS OF THE CODES OF NEW Q 161n oc 9 YORK STATE. NOT RESPONSIBLE FOR o_ DESIGN OR CONSTRUCTION ERRORS. ..� - 2-2x8 treated g m. deck girder TYPCI,4L DECK ELEVATION 2x10 rim board T1'PI,CAL PORCH/DECK FOOTING - �O ALE: 1/811 — 11 II n -�a?rr 12" poured pier footing to SC6 -O,, 8 -O 6 -O a $ a UPANCY OR virgin soil. 4" cca post USE IS UNLAWFUL -see details on this drawing for DECK FRAMING PLAN WITHOUT CERTIFICATE strapping and uplift connections, li SCALE: 1/0 = I'-Oil `'-" `l+ ;.� . OF 1 OF OCCUPANCY �y�p] I CONSTAUCTr.. ': SFALL CERTIFICATION OF 11110 „THE REOUIREMENTSOF THE NAILING 3 CONNECTIONS Cd1ES OF NEW YORK STATE. "" REQUIRED.