Loading...
HomeMy WebLinkAbout30440-Z FORM NO. 4 TOWN OF SOUTHOLD BUILDING DEPARTMENT Office of the Building Inspector Town Hall Southold, N.Y. CERTIFICATE OF OCCUPANCY No: Z-31157 Date: 09/14/05 THIS CERTIFIES that the building ACCESSORY Location of Property: 1200 THERESA DR MATTITUCK (HOUSE NO.) (STREET) (HAMLET) County Tax Map No. 473889 Section 115 Block 13 Lot 14 subdivision Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated JUNE 22, 2004 pursuant to which Building Permit No. 30440-Z dated JUNE 25, 2004 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is ACCESSORY ABOVE GROUND SWIMMING POOL WITH FENCE TO CODE IN THE REQUIRED REAR YARD AS APPLIED FOR. The certificate is issued to ROBERT & ROBERTA TERRANO (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL N/A ELECTRICAL CERTIFICATE NO. 2066244 08/16/05 PLUMBERS CERTIFICATION DATED N/A Au horized Signature Rev. 1/81 Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT N 5 TOWN BALL i ' ? 765-1802 D 1320 APPLICATION FOR CERTIFICATE OF OCCUPANCY[__ -I This application must be filled in by typewriter or ink and submitted to the Building Debertnrenr tx,ttli the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings, property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of I o lead. 5. Commercial building, industrial building, multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings (prior to April 9, 1957) uou-conforming uses, or buildings and"pre-existing" land uses: 1. Accurate survey of property showing all property lines, streets, building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied, the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy- New dwelling$25.00, Additions to dwelling $25.00, Alterations to dwelling$25.00, Swimming pool$25.00, Accessory building$25.00, Additions to accessory building $25.00, Businesses $50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy - $.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy - Residential $15.00, Commercial$15.00 5 Date. 1` o -,O S New Construction: Old or Pre-existing Building: _ (check one) Location of Property: eees y Q?A'%j e- A—'7`f%cXCC House No. tStreet Handet Owner or Owners of Property: W c"AA✓o Suffolk County Tax Map No 1000, Section Block Lot Subdivision Filed blap. Lot: Permit No. 3 0 Date of Permit. b"Z S ort Applicant: PA ert Tg een .o Health Dept. Approval: Underwriters Approval: Planning Board Approval Request for: Temporary Certificate Final Certificate: (check one) Fee Submitted: $ C �8 9Q 3 Applicant Signature Co 31157 O cPrJ'rr� r�rJr�rJ� r1r�rJ�r�rJ� rJ'� r�rnrJ�rJr�r�c1�rPcPPrJrJ'a cncPr�rJ'�rJ� D 5 BY THIS CERTIFICATE OF COMPLIANCE THE 5 5 5 NEW YORK BOARD OF FIRE UNDERWRITERSBURE5 40 FULTTON ST`REETTF ELECTRICITY NEW YORK, NY 10038 5 CERTIFIES THAT 5 5 Upon the application of upon premises owned by 5 ROBERT TERRANO ROBERT TERRANO 5 1200 TERESA D 1200 MATTITUCK NYR4R 11952 MATTITUCK, NY11952 5 Located at 1200 TERESA DR MATTITUCK, NY 11952 5 e5 Application Number: 2066244 Certificate Number: 2066244 Section: Block: Lot: Building Permit: BDC: ns11 5 Described as a Residential 0-599 square ft. occupancy, wherein the premises electrical system consisting of 5 5 electrical devices and wiring, described below, located in/on the premises at: 5 pool only,Attached Garage,Outside, PoolVSpa, 5 A visual inspection of the premises electrical system, limited to electrical devices and wiring to the extent detailed 5 5 herein, was conducted in accordance with the requirements of the applicable code and/or standard 5 5 promulgated by the State of New York, Department of State Code Enforcement and Administration, or other c5 5 authority having jurisdiction, and found to be in compliance therewith on the 16th Day of August,2005. 5 5 Name OTY Rate Rating Circuit Tuve 5 5 Appliances and Accessories 5 5 Pool/Spa Bonding 1 0 5 5 Wiring and Devices 5 5 Switch 1 0 General Purpose 5 �5] Receptacle 1 0 20 amp Pool/Spa S 5 GFCI Circuit Breaker 1 0 20 amp Pool/Spa c5 (Swimming Pool):This certificate covers compliance at the date of inspection only. Because of unusual environments it is advisable to have 5 frequent test and/or repairs made by a qualified person. SO 5 5 5 5 5 seal S 1 of 1 5 certificate may not be altered in any way and is validated only by the presence of a raised seal at the location indicated. 5 FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 30440 Z Date JUNE 25 , 2004 Permission is hereby granted to : ROBERT & ROBERTA TERRANO 1200 THERESA DRIVE MATTITUCK,NY 11952 for CONSTRUCTION OF AN ABOVE GROUND SWIMMING POOL WITH FENCE TO CODE IN THE REQUIRED REAR YARD AS APPLIED FOR at premises located at 1200 THERESA DR MATTITUCK County Tax Map No. 473889 Section 115 Block 0013 Lot No. 014 pursuant to application dated JUNE 22 , 2004 and approved by the Building Inspector to expire on DECEMBER)- 25, 2005 . Fee $ 150 . 00 riz Signature ORIGINAL Rev. 5/8/02 765.1802 BUILDING DEPT. INSPECTION [ ] FOUNDATION 1 ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING FINAL 4 ; [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION REMARKS: Fk- fJ2-A= ' pL 0 DATE INSPECTOR 3 o 1�0 z. 765.1802 BUILDING DEPT. INSPECTION [ ] FOUNDATION 1 ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION / [ ] FRAMING FINAL rD o L [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION REMARKS: DATE ! �O? OS INSPECTOR ' r TOWN OF SOUTHOLD PROPERTY RECORD CARD -L OWNER STREET VILLAGE DIST. SUB. Ro best �rrano - ors. .- .g 'L -, ale Cie&eK &54. FORMER OWNER N E ACR. ,nmonow6k4 Ol,ko d Rn 4ae r Q j is S W TYPE OF BUILDING H. Posq,vowsKr IES. ; SEAS. VL FARM COMM. CB. MISC. Mkt. Value LAND IMP. TOTAL /DATE REMARKS Y,• / 'e 6 #3�- ' 7' * 7iG o o . PoSRNow6K� 1140 .0 a a 5 v (p ` r�� � p a�T P Te R. 2,i v .412_ oo S` 3ba 3 /Z 't :% 6 it � � 00 o o S o SSG o 0 li- 0 �ej • 16 p9`7 L ZG is G� 0 67odDINGC DTO NEW/46 0 0 L L gf� 7 /3 9�- �� - t bel' ��I,Oh r �rCC 3z1 �Z non, FARM Acre Value Per Valuef(o5r$oo /(odo 7:2-400 Acrq,Y4PaO manoosk" akD 4-o Ierrana' ors• rillD T- S rillable 2 Tillable 3 Noodland swampland FRONTAGE ON WATER 3rushfand FRONTAGE ON ROAD lousePlot DEPTH BULKHEAD dotalDOCK ■■■■■■ MEN■■■■■■■■■■ BEE ■■■ ■■■■■■� ■■■■■■■■■■■■■■■■■■■ i l` ■■■■■■ ■■■■■■■■■■■■■■■■■■■ i1 A ■■■■■■■ ■■■ww■■■■■■■■■■■■■■■■ MENEM ■■■■■■e■■■■■■■ire► �illl■■■i■■■■■■i Dwfdation C. Both t . . B ment ®� ��� w FIEL INSPECTION REPORT DATE COMMENTS �T FOUNDATION(1ST) (� y ---------------------------------- �C _y FOUNDATION(2ND) • x 0 U � ROUGH FRAMING& PLUMBING y 'e INSULATION PER N.Y. STATE ENERGY CODE 0,7 FINAL % 4L d ADDITIONAL COMMENTS z m A V O p ✓, z m � I � TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN IIALL Board of Health SOUTHOLD, NY 11971 4 sets of Building Plans TEL: (631) 765-1802 Planning Board approval FAX: 631 765-9502 Survey— www.( ) 3v y www. northfork.net/Southold/ PERMIT NO. Check Septic Form N.Y.S.D.E.C. Trustees Examined L ,20 `� Contact: Approved 20---1 Mail to: Disapproved a/c Phone: Expiration20� <a) — Building JUN 2 2 2004 APPLICATION FOR BUILDING PERMIT _ Date fo -2'Z , 200v -� INSTRUCTIONS a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale.Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas,and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e. No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize,in writing,the extension of the permit for an addition six months.Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York, and other applicable Laws,Ordinances or Regulations, for the construction of buildings, additions,or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws,ordinances,building code,housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. (Signature of applicant or name,if a corporation) /2.sb Thertgsn DR M!1'j"I'ITt,cIC (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician,plumber or builder vw .-F2 v Name of owner of premises role^+ 1' y' OVA(J �z�6 (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. Plumbers License No. Electricians License No. Other Trade's License No. 1. Location of land on which proposed work will be done: r 12ro -rkenESA 01L M0.rrlT✓ctC House Number Street Hamlet County Tax Map No. 1000 Section /I Block / 71 Lot Subdivision PG P tiot.b CUiV- LSTs i fs Filed Map No. 42,,x. Lot t o (Name) 2. State existing use and occupancy of premises and intended use and occupancy of proposed constnictioni a. Existing use and occupancy 5)I+LLK �PM;,�Y 0E�c9 b. Intended use and occupancy Sp M� 3. Nature of work(check which applicable): New Building Addition Alteration Repair Removal Demolition Other Work R' V--vn A Do)e 6o-,, o P.01- (Description) 4. Estimated Cost 690 ! Fee (To be paid on filing this application) 5. If dwelling, number of dwelling units Number of dwelling units on each floor If garage, number of cars 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front oa• L Rear Depth 2 8, 3 Height I L Number of Stories I Dimensions of same structure with alterations or additions: Front 108• z Rear �'$ •i Depth U . 3' Height U. ' Number of Stories 1 8. Dimensions of entire new construction: Front 18 G MotAV- Rear Depth Height Number of Stories r 9. Size of lot: Front 19 01 Rear 2�(0 Depth 2r a 10. Date of Purchase O'n- Name of Former Owner Nt:�jK, + YDAu 11. Zone or use district in which premises are situated 4S f DfNTi qc- 12. Does proposed construction violate any zoning law, ordinance or regulation? YES_NO �o 13. Will lot be re-graded? YES_NO X Will excess fill be removed from premises? YES NO )a Tk,HAS �kt�6 14. Names of Owner of premises 7tlZ4ro Address Itop 'TKe/gsn h? Phone No. (31 2-98-70? Name of Architect Address Phone No Name of Contractor Address Phone No. 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO X * IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO_X _ * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. STATE OF NEW YORK) S COUNTY O — being duly swom, deposes and says that(s)he is the applicant (Name of individual signing contract) above named, (S)He is the (Contractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. Swo o before me t day 200 otary Pub Tic Signature of Applicant PAMM CORmN NIVY Public,State of New York 110.DIC05017852 m Su0o1k 0euub `,es Sept 13,�DOf LOT o @6,34' r ^ �,;rs. tncs o 4 g Nr 80' r T' p00 P.p• a 1 } !��• moo' 1 Lo 1 a g N i 01�, LO N a 0 w i x $ o" ,,s. r o 96 Zoo' "WE 60 �f �.-✓6a'.�0 S AREA 45, 120 sq.ft. pAIDw� 5 SURVEY OF CeTI rot LOTS 9 & 10 rgrr RO AAWWSM "DES* GREEK ESM TES" J"IV ROMAWWSn M fWAaIIIA �r ATrf. TT/TU K TOW SOU�OLD SU+�F K COUNTY, N. Y. vw - 116- 13- 9 Scale: 1" = 30' July 149 1992 �0 iAND SG fS Q5J► �. L NO 496/8 prsporad M acaordmxv MSN► me n**V m s/ondards to Nth sorwys as ast4bMrftd P.C. by the LIA.L.S. and a�prowd and odrlod tJ/6J for sIr usa Ar rhe New Yak We LLa P. O. TlNe AssoeMllon. � TMXDO MY. 11971 92-223 UNDERWRITERscERTIFlCAiIP APPROVED MUMBROUNM 8Re�'SMAS REQUIRED *s � 30440 DATE: B.P.tt� FEE: BY: OCCUPANCY OR • 9 NOTFY BUI G DEPARTMENT AT 8 OR THE USE IS UNLAWFU wIWofFi�nneAbove PI WITHOUT CERTIFIT ED kers AOG UANG OF OCCUPANCY 313 Regina Avenue Rahway, New J" -4891 4. FI AL - CONSTRUCTION MUST BE COMPLETE FOR C.O. POOL ASSEMBLY and INSTALLAMR��AiNS YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. �= • ; i 'rte yD . MEDIATELY ENCLOSE POOL TO CODE UPON COMPLETION BEFORE"WATER" DANGER DO NOT DIVE OR JUMP into your pool. Your pool is approximately 4' deep. It Is not designed for diving or jumping. If you dive or jump into your pool you run the risk of permanent Injury or death. Alert all visitors and family of this and point out all warning labels supplied. GENERAL Installation of this above ground pool is not extremely hard or confusing, but it is a big job. The secret to installing a pool so that it will give you years of pleasure is to take the time to follow instructions and do things right the first time Your pool warranty is void if these instructions are not followed 100%. Read all instructions Including accessories such as filters, pumps, skimmers, decks, etc. prior to starting. Any aftermarket or home built deck, if allowed, should be constructed according to all local building code requirements, including load capacity and fencing requirements. Before you start, check to see that you have the correct number of parts. Use your parts list which is broken down by carton. The manufacturer reserves the right to revise, change, or modify construction of their pools. NOTE: If a power drill is used during installation, it should be a variable speed drill used on low setting. Torque should not exceed 39 inch Pounds. Failure to comply could result in screws stripping out. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THF CONTRACT INSTALLATIONS The manufacturer is in no way affiliated with any professional pool installer. Therefore the manufacturer can assume no responsibility, for errors in installation by the home owner or said professional installer. If you have your pool installed by others, please supervise to be sure they comply with the proper installation techniques shown. Their past experience or short cuts may not cover the latest improvements in our pools. Do not allow any short cuts of any nature. LOCAL CODES Local building code may require obtaining a building permit and may have regulations on set backs, barriers, devices and other conditions that must be followed. Any after market or home built deck should be built to the local building code requirements, including load capacity and fencing requirements. Local electrical code may require obtaining a building permit and may have regulations on setbacks, devices and other conditions that must be followed. All electrical outlet connections should be a minimum of 5 feet from the outside perimeter of the wall of the pool. From 5-10 feet there should be either a fixed connection (outlet box) or twistlock connection with a GFCI. Connect power cords to a 3-wire grounding-type outlet only. Severe electrical shock could result if you install your pump or filter on a deck. They could fall into the water, causing Severe shock or electrocution. Do not install on a deck or other surface at, above or slightly below the top seat of the pool. BARRIER REQUIREMENTS If the distance from the top of the assembled pool is less than 48"vertically from the surrounding grade, a fence or barrier is needed to surround the pool with a minimum height of 48". A barrier is necessary to provide protection against potential drowning and near drowning and is not a substitute for constant supervision of children. A barrier is a fence, wall, or a combination thereof which completely surrounds the swimming pool and obstructs access to the swimming pool. Barriers must comply with local and national building codes and the US Consumer Product Safety Commission. These are minimum fencing and barrier requirements. Check your local building codes for other requirements they may request. optional fencing kits are available, please contact your local dealer. If pool covers are used for safety barriers they should comply with ASTM F 1346 "Standard Performance Specification for Safety Covers and Labeling Requirements for All Covers for Swimming Pools, Spas and Hot Tubs." SPECIAL CARE Even though this manufacturer's pools are designed to meet or exceed industry recommended safety factors, special attention must be paid to some installation procedures that the installer performs and controls. • Levelness -- spend the time to assure that the entire pool framework is level within 1". Unlevel pools place extreme pressures on the pool walls • Wall seam -- this area is where the wall joins together. Damage to any part of this area reduces the safety factors and can result in a weak pool. Use extreme care following instructions. • Earth mound --this keeps the liner from creeping out from under the pool wall. Follow instructions to the letter--don't short-cut or substitute materials. Improperly installed pools can rupture, allowing thousands of gallons of water to rush out causing extensive property damage and injury to anyone in its path. • This manufacturers pools are not designed to be buried. Outside ground forces can collapse pool wall. • The pool owner has the sole responsibility for providing adequate lighting for the pool area. It is important that all users must be able to see the shallow depth of the pool, and safety signs at all times. • You must install a pool ladder(s)for entry and exit from the pool. • All components such as the filtration system, pumps and heater should be positioned as to prevent their being used as a means of access to the pool by young children. PAGE 2 INSTALLATION/ASSEMBLY STEPS READ CAREFULLY BEFORE STARTING POOL ASSEMBLY CONSTRUCTION CLOSE-UPS USE THE ILLUSTRATIONS BELOW AS A GUIDE FOR ASSEMBLY OF YOUR POOL F . A FIG. B _7' FIG. C \ Al - ti1 II � �� 4"LEDGE 6"LEDGE 6"OR 7" LEDGE 4"VERTICAL 6"VERTICAL 6"VERTICAL FIG. D FIG. E FIG. F 6' EXTRUDED LEDGE 7'/." EXTRUDED LEDGE 9" LEDGE 6" EXTRUDED VERTICAL 7" EXTRUDED VERTICAL 8"VERTICAL PAGE 4 2 BOTTOM RAIL 1 BOTTOM RAIL VERTICAL BOTTOM PLATE PRE WASHED SAND OR BOTTOM RAIL SIFTED EARTH RECOMMENDED I� _ REQUIREMENT CHART ! W 12 x 48 1.9 Tons 1.5 Yards 15 x 48 2.6 Tons 2 Yards 18 x 48 3.4 Tons 2.6 Yards ��BOTTOM PLATE 21 x48 4.3 Tons 3.2 Yards OPTIONAL GROUND SHIELD 24 x 48 5.3 Tons 4 Yards PATIO BLOCK �"_ ----- i 27 x 48 6.3 Tons 4.7 Yards 1/16" round-.S"ld-i-nd V IG—u -rd8f8 OptI0n8I. Spread a ground shield or plastic sheeting over prepared ground (not included). Ground Shield and Wall Guard are available from your local pool supply dealer or polyethylene sheeting can be purchased from a local hardware supply. This will protect your pool liner and metal parts against chemical reactions from the ground soil. Mark out pool radius (1/2 pool diameter) using the center stake as reference. Form a circle by sliding bottom rail groove up, into the bottom plates 1/16" from the stop. Bring the required amount of sifted earth or prewashed sand into the pool area at this time. Refer to chart above for the required amount. Place patio blocks under each bottom plate at ground level. Check the levelness from the center stake to each patio block. 3 1 . INSERT WALL INTO BOTTOM RAIL Remove wall from carton. NOTE: the UP arrow on wall. Determine starting point as the filter inlet and outlet holes are at the beginning of the wall. Starting at 4' 4' Plywood the center of a bottom plate insert the bottom edge of wall into the groove on the bottom rail. Make sure that the cutouts for filter inlet I I I III and outlet are on the top portion of the wall and will not be hidden behind a vertical. If the wall ends do not meet, adjust the bottom rail in or out of the bottom plates. The SKIMM R INLET spacing in all bottom plates should SKIMM R OUTLET be equal. PAGE 3 D 11NBTRUCTPOOLV20UND\B"203&P.SA6 Rev 1158 Swim'ri PLy lace Makers of.amine .1.6ove Ground Pools 313 Regina Avenue Rahway, New Jersey 07065-4891 POOL ASSEMBLY and INSTALLATION INSTRUCTIONS w 1 1 DANGER DO NOT DIVE OR JUMP into your pool. Your pool is ., approximately 4' deep. It is not designed for diving or ajumping. If you dive or jump Into your pool you run the __w^ risk of permanent injury or death. Alert all visitors and family of this and point out all warning labels supplied. GENERAL Installation of this above ground pool is not extremely hard or confusing, but it is a big job. The secret to installing a pool so that it will give you years of pleasure is to take the time to follow instructions and do things right the first time Your pool warranty is void if these instructions are not followed 100%. Read all instructions including accessories such as filters, pumps, skimmers, decks, etc. prior to starting. Any aftermarket or home built deck, if allowed, should be constructed according to all local building code requirements, including load capacity and fencing requirements. Before you start, check to see that you have the correct number of parts. Use your parts list which is broken down by carton. The manufacturer reserves the right to revise, change, or modify construction of their pools. NOTE: If a power drill is used during installation, it should be a variable speed drill used on low setting. Torque should not exceed 39 inch Pounds. Failure to comply could result in screws stripping out. CONTRACT INSTALLATIONS The manufacturer is in no way affiliated with any professional pool installer. Therefore the manufacturer can assume no responsibility, for errors in installation by the home owner or said professional installer. If you have your pool installed by others, please supervise to be sure they comply with the proper installation techniques shown. Their past experience or short cuts may not cover the latest improvements in our pools. Do not allow any short cuts of any nature. LOCAL CODES Local building code may require obtaining a building permit and may have regulations on set backs, barriers, devices and other conditions that must be followed. Any after market or home built deck should be built to the local building code requirements, including load capacity and fencing requirements. Local electrical code may require obtaining a building permit and may have regulations on setbacks, devices and other conditions that must be followed. All electrical outlet connections should be a minimum of 5 feet from the outside perimeter of the wall of the pool. From 5-10 feet there should be either a fixed connection (outlet box) or twistlock connection with a GFCI. Connect power cords to a 3-wire grounding-type outlet only. Severe electrical shock could result if you install your pump or filter on a deck. They could fall into the water, causing Severe shock or electrocution. Do not install on a deck or other surface at, above or slightly below the top seat of the pool. BARRIER REQUIREMENTS If the distance from the top of the assembled pool is less than 48" vertically from the surrounding grade, a fence or barrier is needed to surround the pool with a minimum height of 48". A barrier is necessary to provide protection against potential drowning and near drowning and is not a substitute for constant supervision of children. A barrier is a fence, wall, or a combination thereof which completely surrounds the swimming pool and obstructs access to the swimming pool. Barriers must comply with local and national building codes and the US Consumer Product Safety Commission. These are minimum fencing and barrier requirements. Check your local building codes for other requirements they may request. optional fencing kits are available, please contact your local dealer. If pool covers are used for safety barriers they should comply with ASTM F 1346 "Standard Performance Specification for Safety Covers and Labeling Requirements for All Covers for Swimming Pools, Spas and Hot Tubs." SPECIAL CARE Even though this manufacturer's pools are designed to meet or exceed industry recommended safety factors, special attention must be paid to some installation procedures that the installer performs and controls. • Levelness -- spend the time to assure that the entire pool framework is level within 1". Unlevel pools place extreme pressures on the pool walls • Wall seam -- this area is where the wall joins together. Damage to any part of this area reduces the safety factors and can result in a weak pool. Use extreme care following instructions. • Earth mound ---this keeps the liner from creeping out from under the pool wall. Follow instructions to the letter—don't short-cut or substitute materials. Improperly installed pools can rupture, allowing thousands of gallons of water to rush out causing extensive property damage and injury to anyone in its path. • This manufacturers pools are not designed to be buried. Outside ground forces can collapse pool wall. • The pool owner has the sole responsibility for providing adequate lighting for the pool area. It is important that all users must be able to see the shallow depth of the pool, and safety signs at all times. • You must install a pool ladder(s) for entry and exit from the pool. • All components such as the filtration system, pumps and heater should be positioned as to prevent their being used as a means of access to the pool by young children. PAGE 2 INSTALLATION/ASSEMBLY STEPS READ CAREFULLY BEFORE STARTING POOL ASSEMBLY CONSTRUCTION CLOSE-UPS USE THE ILLUSTRATIONS BELOW AS A GUIDE FOR ASSEMBLY OF YOUR POOL FIG. A FIG. B -71 FIG. C --------------------- IL - „ ii ,,�, ; 4" LEDGE 6"LEDGE 6"OR 7"LEDGE 4"VERTICAL 6"VERTICAL 6"VERTICAL C--\ FIG. D FIG., E FIG. F IL � I 6" EXTRUDED LEDGE 7%" EXTRUDED LEDGE 9" LEDGE 6"EXTRUDED VERTICAL 7" EXTRUDED VERTICAL 8"VERTICAL PAGE 4 2 BOTTOM RAIL BOTTOM RAIL VERTICAL BOTTOM PLATE PRE WASHED SAND OR BOTTOM RAIL SIFTED EARTH RECOMMENDED REQUIREMENT CHART .0 12 x 48 1.9 Tons 1.5 Yards 15 x 48 2.6 Tons 2 Yards ��� 18 x 48 3.4 Tons 2.6 Yards -- .BOTTOM - ,����PLATE 21 x48 4.3 Tons 3.2 Yards OPTIONAL GROUND SHIELD 24 x 48 5.3 Tons 4 Yards . PATIO BLOCK 27 x 48 6.3 Tons 4.7 Yards 'l.- /' 1/16" Ground-Shteld wnd Watt Guar�are optional. Spread a ground shield or plastic sheeting over prepared ground (not included). Ground Shield and Wall Guard are available from your local pool supply dealer or polyethylene sheeting can be purchased from a local hardware supply. This will protect your pool liner and metal parts against chemical reactions from the ground soil. Mark out pool radius (1/2 pool diameter) using the center stake as reference. Form a circle by sliding bottom rail groove up, into the bottom plates 1/16" from the stop. Bring the required amount of sifted earth or prewashed sand into the pool area at this time. Refer to chart above for the required amount. Place patio blocks under each bottom plate at ground level. Check the levelness from the center stake to each patio block. 3 INSERT WALL INTO BOTTOM RAIL Remove wall from carton. NOTE: the UP arrow on wall. Determine starting point as the filter inlet and outlet holes are at the beginning of the wall. Starting at 4' 4' Plywood the center of a bottom plate insert the bottom edge of wall into the groove on the bottom rail. Make sure that the cutouts for filter inlet I I ,III and outlet are on the top portion of the wall and will not be hidden behind a vertical. If the wall ends do not meet, adjust the bottom rail in or out of the bottom plates. The SKIMM R INLET spacing in all bottom plates should SKIMM R OUTLET be equal. PAGE 6 M2032e - E.0 STRUMECMFENSRND SAM Rev 444 «:z..::r:-xm:x,x;:<..u::a:..w::o:;::<us:ue:::::<ex<wuumn.ro::.x::un:n::<u-.<.,,:,.e:....-rr '.r _e:«..».:•.w<.x: FENSURROUND ASSEMBLY INSTRUCTIONS s ' y DANGER l)D NOT DIVE OR JUMP into your pool. Your pool is FENEW approximately 4' deep. It Is not designed for diving or Q. ..4 jumping. If you dive or jump into your pool you run the r__ `N' risk of permanent Injury or death. Alert all visitors and r+ family of this and point out all warning labels supplied. stwim n PI , Inc. Maffrs of,fFine Above Ground Poors 313 Regina Avenue Rahway, New Jersey 07085-4891 I a. Assemble the Square Fence Post to the Post Bracket using the 14" x 20 x 2" Screws and Hex Nuts as shown at right. If your pool is equipped with Full-Contoured Covers like those below, you must first assemble the covers to the pool before attaching the Posts. 1/4"X204* 1/4"X20 HEX TRUSS HEAD SCREW NUT FENCE POST POST CAP OBRACKET POST Attach the Fence Brackets to the top of the Posts simply by inserting the oval end into the slot in the Post and pressing down-as shown. Next, press one Post Cap to the top of each Post. sA— ENSURROUND WITH PACKING LIST twun n Inc.• ,ncPART#420339 Rev. 111D5' -7�1ukF�'[!fl'lrtta6[ney'ronn[!4[ih+/s 36" WHITE FENCE CAACK9dGfi;ENSL0t4tSW` PART# DESCRIPTION 112x48 15x48 8x48 21x48 24x48 27x48 l8xl 2194xl2 21x15 24x15 30x15 24xl 81 33x18 45x1 CARTON 1 190983, 42 3/4•POST 10 10 12 14 16 18 12 14 16 16 16 18 18 22 190989 POST BRACKET 20 20 24 28 32 36 24 28 32 32 32 1 36 38 44 191001 UNIV FENCE BRCKT 40 40 48 56 64 72 48 56 64 64 64 72 72 88 360161 POST CAP 10 10 12 14 16 18 12 14 16 16 16 18 18 22 420338 INSTRUCTIONS 1 1 1 1 1 1 1 1 1 1 1 1 1 420339 PACKING LIST 1 1 1 1 1 1 1 1 1 1 1 1 1 ; 1 420446 30 YEAR WARRANTY 1 1 1 1 1 1 1 1 1 1 1 1 1 1 460050 2" BOLT 10 10 12 14 16 18 12 14 16 16 16 18 18 22 460009 3/4"BOLT 40 40 48 56 64 72 48 56 64 64 64 72 72 88 460135 #10 x 1/2"SHEET 40 40 48 56 64 72 48 56 64 64 64 72 72 88 METAL SCREW 460090 HEX NUT 50 50 60 70 80 1 90 1 60 70 80 80 80 90 90 110 460131 FENDER WASHER 40 40 48 56 64 1 72 1 48 56 64 64 64 72 1 72 1 88 460155 #10 RUBBER CAP 40 40 48 56 64 1 72 1 48 56 64 64 64 72 72 1 88 CARTON 2 500533 57" FENCE - 10 12 7 9 9 - - 7 7 7 7 1 9 []2 500530 47" FENCE 10 - - - _ _ 7 7 C.4RTGN� 57" FENCE - - - 7 7 9 - - 3 3 3 5 3 - �'°� 500537 69118"FENCE - - - - - 2 4 - 4 - 4 8 500530 47"FENCE - - - - - - 3 3 500525 33" FENCE - - - - - - - - 6 2 - 2 2 500523 2511/16"FENCE - - - _ _ _ _ _ 2 - - 2 - - 500522 22"FENCE - - - - - - - - 4 - WARNINGI POOLS NOT DESIGNED FOR DIVING JUMPING1111 �ViLllll\lS rL`itl�ll1 iLl�tllrlil\L`Al.i1L1.111-r1�.71 DATE REVIEWED: t /2 103 APPLICANT 2AtjQ DATE SUBMITTED: 6 /js/03 SCTM#DISTRICT: 1,000, SECTION: 115 ,BLOCK: ►3 ,LOT: 14 SUBDIVISION:-DeeP k W "t ADDRESS: CITY: ka+rbr_L zONING DISTRICT: CONFORMING?' q BUILDING PERMITS OPEN/EXPIRED: PRE CO: Y OR N BP -Z/C/0 Z- , INFO Z_/BP -Z/C/0 Z- , INFO BP -Z/C/0 Z- , INFO /BP -Z/C/0 Z- , INFO SINGLE & SEPARATE CERTIFICATION-REQUIRED -- NOTES: " LOTS 40,0008F-100-24.Lot recognition.(CREATED before June 30,1983),UNDERSIZED LOTS FROM JAN.1997 100-25.Merger.(A nonconforming at any time after' REQ. LOT SIZE: ACT. LOT SIZE:IK',$02 REQ. LOT COV. -2 O� ACT. LOT COV. REQ. FRONT PROP. FRONT �KEQ SIDE ID�IO ACT. SIDE REQ. REAR i p PROP. REAR / REQ.(HEIGHT PROP. HEIGHT PROJECT DESCRIPTION: 'C ESTIMATED PROJECT COST: ARCHITECT/ENGINEER: N 'A WATER FRONT? DESCRIPTION: ANEL # FLOOD ZONE APPROVALS REQUIRED SUFFOLK COUNTY HEALTH DEPT: YES or62JBED#): DTE:_/ /_ PERMIT#: TOWN SEPTIC RECEIPT: Y 010 NEW YORK STATE DEC: PRE-DEC 9/1/75 YES or 10. DTE: PERMIT#: SOUTHOLD TOWN TRUSTEES: YES or DTE__/ /_ PERMIT#: TOWN ZONING BOARD APPROVAL: YES o DTE: /_/_ PERMIT#: TOWN PLAN. BO RD APPROVAL: YES or D� _/_/ PERMIT#: TOWN HISTORI AL PRE (SPLIA): YES or NEW YORK STATE CODE COMPLIANCE (SEE PAGE 2): r NO 00p NOTES: FEE STRUCTURE: FOUNDATION: SF FIRST FLOOR: SF SECOND FLOOR: SF OTHER: SF INIT OTHER TOTAL TOTAL: ---- SF FEE FEE FEE 1. _SF)- (SF)= SFX $ =$ +$ +$ =$ 2. ( SF)- ( SF)= SFX $ =$ +$ +$ =$ 3. ( SF)- ( SF)= SFX $ =$ +$ +$ = $ FINAL TOTAL: $ S� NEW YORK STATE CODE COMPLIANCE CHECKLIST CLIMATIC/GEOGRAPHIC DESIGN CRITERIA: Ground Snow Load:45 WInd Speed: 120MPH Seismic Design Category:B Weathering: Severe Frost Depth:36" Termite: M-H Decay: S-M Design Temp: 11 Ice Shield Underlay:YES Flood Hazards: USE/OCCUPANCY CLASSIFICATION: HEIGHT/FIRE AREA: TYPE OF CONSTRUCTION: DESIGN CRITERIA: ENGINEERED/PRESCRIPTIVE FULL FRAMING DESIGN ELEMENTS: Y/N HEADERS: Y/N WALL STUDS:Y/N GIRDFRS: Y/N CEILING JOISTS:Y/N FLOOR JOISTS:Y/N ROOF RAFTERS:Y/N LUMBER SPECIES AND GRADE:Y/N DESIGN LOAD CALCULATIONS: Y/N LIVE: Y/N DEAD:Y/N SNOW:Y/N SEISMIC:Y/N WIND: Y/N WINDOW AND DOOR SCHEDULE: MISSLE TEST REQUIREMEN .S: Y/N J EGRESS 5.7 S.F.: Y/N LIGHT 8%: Y/N VENT 4%: Y/N NAILING/CONSTRUCTION SCHEDULE: Y/N MEANS OF EGRESS: Y/N PLUMBING RISER DIAGRAM: Y/N LOCATION OF FIRE PROTECTION EQUIPMENT: Y/N TRUSS DESIGN: Y/N CERTIFICATION: Y/N ENERGY CALCS: Y/N TOTAL COMPLIENCE? Y/N (RETURN TO PAGE ONE)