Loading...
HomeMy WebLinkAbout29722-Z FORM NO. 4 TOWN OF SOUTHOLD BUILDING DEPARTMENT Office of the Building Inspector Town Hall Southold, N.Y. CERTIFICATE OF OCCUPANCY No: Z-31104 Date: 08/15/05 THIS CERTIFIES that the building ADDITIONS & ALTERATIONS Location of Property: 480 DOGWOOD LA SOUTHOLD (HOUSE NO. ) (STREET) (HAMLET) County Tax Map No. 473889 Section 54 Block 8 Lot 1 Subdivision Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated AUGUST 18, 2003 pursuant to which Building Permit No. 29722-Z dated SEPTEMBER 10, 2003 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is SECOND STORY ADDITION & ALTERATIONS TO EXISTING SINGLE FAMILY DWELLING AS APPLIED FOR. The certificate is issued to DANIEL P & MARY REGAN (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL N/A ELECTRICAL CERTIFICATE NO. 85440C 04/18/04 PLUMBERS CERTIFICATION DATED 08/11/05 DANIEL REGAN A ori ed S gnature Rev. 1/81 Form 6 O TOWN OF DEPARTMENT _ n BUILDING DEPARTMENT (�,1•!i``,�(�. TORN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be tilled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: L Final survey of property with accurate location of all buildings, property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 form). 3. Approval of electrical installation front Board of Fire Underwriters. 4. Swom statement from plumber certifying that the solder used in system contains less than 2/10 of 110 lead. 5. Commercial building, industrial building, multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings (prior to April 9, 1957) non-conforming uses,or buildings and "pre-existing" land uses: 1. Accurate survey of property showing all property lines, streets, building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. if a Certificate of Occupancy is denied, the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees I. Certificate of Occupancy- New dwelling $25.00, Additions to dwelling$25.00, Alterations to dwelling $25.00, Swimming pool $25.00, Accessory building$25.00, Additions to accessory building$25.00, Businesses $50.00. 2. Certificate of Occupancy on Pre-existing Building - $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy- Residential $15.00. Conunercial $15.0[1 Date. // L/O )/ New Construction: Old or Pre-existing Building: t/ (check one) Location of Property: 44 y 6 c qz ,2 n 17 4 11 _�0 U T!� o � (7 �'1/. House No. ' r Street / Han et Otwner or Owners of Property: Al /4-Z 4 V - 04AIl6. g ^J Suffolk Countv Tax Map No 1000, Section 5 V Block Lot Subdivision Filed Map. Lot: Pemtit No. i- 7—Date of Permit. 47 /d o pplicant: Health Dept. Approval: Underwriters Approval: Planting Board Approval: Request for: Temporary Certificate Final Certificate: ✓ (check one) Fee Submitted: $ 2 -3 . 00 Applicant Signature CoQ_- 31)oY Electrical Inspection Certificate Issue Date Electrical Inspection Service,Inc. Application 4/18/2005 375 Dunton Avenue 85440C ` East Patchogue, New York 11772 (631)286-6642 Issued To: Mr. Dan Regan Street: 480 Dogwood Lane Village: Southold Zip: Town: Southold Section: Block: Lot: Contractor: Francis Mc Caffery Electric (L) Lic. # 1145-E Was examined and found to be in compliance with the National Electrical Code. LJ Commercial ❑ NV Defects ❑ Pool X let Floor [I Indoor I] Basement LJ Hot Tub L� Residential ❑ Det.Garage ❑ Attic K 2nd Floor ❑ Outdoor ❑X Addition ❑ Survey Switches Receptacles Fixtures GFI Heaters A/C Fans .a 11 8 5 1 2 ' Dishwasher Washer/Amps Dryer/Amps Oven Range/Amps Microwaves �- Furnace Oil Gas Circulators Smoke Detector Bell Transformer Meter Amps Phase UG/OH Jacuzzi Television CO Detector Bldg. Permit: r( 7 )L- Other Other Equipment q Hugo S. Su i President Rough Inspection: 03/23/2004 Inspector: John McMahon III Final Inspection: 04114/2005 Inspector: John McMahon III This certificate must not be altered in any manner. Inspectors may be identified by their credentials. FAILWAIL / / \ � � AIL A� X . W Town Hall, 53095 Main Road Fax(631)76-S-9502 P.O. Box 1119 Telephone(631)765-1802 Southold, New York 11971-0959 BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATION Date: Building Pennit No. Owner: Al (Please print) Plumber: Z)A,d g 6 ('4 'z (Please print.) I certify that the solder used in the water Supply SySten-1 COntains less than 2/10 of 10"o lead. (Plurf1be9--5+natdrc) Sworn to before me this day of 20tl--j LINDA J HAYES rk Notary PubliC,giate of Now No No OJHA6059622 Quallfio;d in Suffolk COu Cornmission Expires May Notary Public, Count�, FORM NO . 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 29722 Z Date SEPTEMBER 10 , 2003 Permission is hereby granted to: DANIEL P & WF REGAN 1860 N BAYVIEW RD SOUTHOLD,NY 11971 for ADDITIONS (SECOND STORY) AND ALTERATIONS TO AN EXISTING SINGLE FAMILY DWELLING AS APPLIED FOR WITH FLOOD PERMIT at premises located at 480 DOGWOOD LA SOUTHOLD County Tax Map No. 473889 Section 054 Block 0008 Lot No. 001 pursuant to application dated AUGUST 18 , 2003 and approved by the Building Inspector to expire on MARCH 10 , 2005 . Fee $ 364 . 00 / Authorized Signature ORIGINAL Rev. 5/8/02 M-1802 BUILDING DEPT. INSPECTION [ ] FOUNDATION IST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ) INSULATION [ ] FRAMING [ ] FINAL [ ] FIREPLACE CHIMNEY REMARKS. -- Ile 7'1� DATE D� INSPECTO 765-1802 BUILDING DEPT. INSPECTION [ ] FOUNDATION IST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING [ ] FINAL [ ] FIREPLACE A C IMNEY REMARKS: I DATE d n � INSPECTO ' 765.1802 BUILDING DEPT. INSPE7RO T ON [ ] FOUNDATION IST H PLBG. FOU�IDAflON 2ND SOLATION ]'FRAMING [ ] FINAL [ ] FIREPLACE & C� MNEY [ ] FIRE SAFETY INSPECTION REM A S. DATE INSPECTO 765.1802 BUILDING DEPT. INSPECTION [ ] FOUNDATION IST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSU TION [ ] FRAMING [ Aor INAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION REMARKS: G DATE ll/ f/—/Of INSPECTOR FIELD 1NSnmoN REPORT I DATE L copmam .A o FOUNDATION(1ST) m FOUNDATION(2ND) t Z O ® O O ROUGH ERANUNG& H PLUMBING INSULATION PER N.Y. :5 STATE ENERGY CODE 3 iJ� o FINAL ADDITIONAL COMMENTS Q .h cl 'W OSP<1 S i :5 O z m S � c� q= 0 x .It I-,y: BARRETT ROtIACCI .3 VAIs KEI r: 031 435 1022; Jan-5-C' 3:1SPIA; Page 2/2 L;ertaicatlons Indicated Lnr.enr .lyolfy lhol this pial a( the hveon deocrlhed Properly I. a I'. and OOrr.nt rrpr.senlallan of C reC.nl .U.eq mnoe end VI.tl.d •inner my dlrsetlUn In ucevrdonce with Ole existing Code of Practice for Lond Surveyor* by the New York Sate A.1o0.t,en of Prolse.ionol Lond SUr,uwyr's Soid per liNco Unn* 011,11 run only to the Pwrwah (or whom the survey Is Prep Oree Ono on Ihelr [..hell 1,, he hnw r n,P n..y. yO.ernm n,llni ""'n y arld lend�ny ...xlilwr llOn Ilslod hereon. !ills cortitOotlon is only (or the lane* oe*crlb.d n er0w+. C. nr henrl1,rn horn C•momberonce s. CertifiCollon9 Ore not IroMferable to addnlon Ol IneOlUllons wuhxeno e•II o»ner0 I AND NOW OR FORMERLY OF DANII 1. 1'. do WF REGAN 1�1 N 47'49'40'* E '�� E 50.00' rE I/ 1 f, 14 r f I� Inh COULAn SNOw rt'.C� �_ 11 V sE 01 IN MONUMENT y If FOUND 1S'E _ Ig � try--{ ww W WU F P Z tp� wit°j.Nya4N.cs ['gC1Z.4it € M k al N 206 W O OY I O U TONY u N zz` q r S FRAM p1G .. 0 O Qf V OWE3f03D5 CO) If e ,D> V)o tO Z ' o - O o Wr C, O In Ny J V < l Fl z � ' r N k I 0 is CURB a .�.1 C F0.14 - rE 1.7'N J o s's uONUM[NT MLINO L / M'wu,g Pte/ FwEN ''/i LM: SURVEY NEW: PLOT rho a/4ae OF dimensions who." Irom Ih. efruelur.. la In. Property (into Ore for o .p,,ifi, purpose and gee unit therefore or. not lht.ndgd to pV+d. iw the .r,CIIyl e/ 4ne.0. r1,einln -all*' Coedltfons net .hewn. 4,,,.«,,, w w,,.r0, x « PONS' Pnue<, pIOnIMg epee. eddglene to bWldlnp. end any OIhor ....jru011on Sublwleee --n MI Nx�v IrNY1r Nin« n,Mn,«I, �Y,nal yMN N , ,MI ,r r,y ywµ e 20111 p p V,p.f. Barrett Bonacci & Van Weele P.C. I TNDRIEALTERATION O T ADDITION 70OT A. THIS SURVEY IS A .r+ 'C;';IL C"n3iticcfi riai.ii'r 67muge, LAIJNERS LW 'FORK PTE EDUCATION TION OF 175A Fmm�vrr:e Ornq Ilannl>auge.NY 11788 NEW YORK 9iAn EtluCA RON lAw TFL6.31M35-1111 FA X 6.11/439.1022 www bbvpc.cnrn LOT: — BLOCK_ — REVISIONS: ...._—, _..._,_ FILED: — NO. — CO- SUFFOLK SITUATED: SOUTHOLD_TOWN THIS SURVEY MAP NOT CERTIFIED TO: TITLE NO.: CAPLS-10846-5 BEARIPIC THE LANb SURVEYOR'S SEAND SICNATU A5TORIA FEDERAL SAVTNGS AND LOAN ASSOCIATION SHBOSSNOT FJE CONSIDERED To CHICAGO TITLE INSURANCE COMPANY BE A TRUE AND VALID COPY. JOAN GEORGIADES JOB NO.: A000976 DATE: JAN 2, 2001 DR. JAM CH. -- SCALE: I- ?O' DIST. 1000 SEC. 54 BLK. 8 LOT 8 f' TOWN OF SOUTHOLD PROPERTY _RECORD CARD v OWNER STREET VILLAGE DIST. SUB. LOT FORMER OWNER 1 ; NCS/ -U. E��ry n�-G...",_c _ s �• sa Y S/JW TYPE OF BUILDING r RES. SEAS. VL. FARM COMM. CB. MISC. Mkt. Value LAND IMP. TOTAL DATE REMARKS ✓Ne n� DD YGO 'yo (1 armee !is- L i a`ov � L7145a94 000 X113 Pc s *as f fed' 5;o" o b 117 ,ew r �..t 4/a6yfL_ 1J.� F Elsa. '�/ �o -2--- 7 4. y7.. AGE B ILDING C DITI N 1jo (e S NEW 7QO LW / FARM Acre Value Per alue 70-0 2 7 co Acre 2- Tillable Tillable 1 Tillable 2 Tillable 3 Woodland Swampland FRONTAGE ON WATER Brushland FRONTAGE ON ROAD House Plot DEPTH BULKHEAD Total DOCK L ---- ---- {COLOR fq 1 Y � .. TRIM J • — - --- M. Bldg. /ls'ZyFoundation Bath / Dinette Extension /4, Basement GRAW Floors K. — Extension 'Ext. Walls �) .g- � � r Interior Finish S�. LR -- Extension Fire Place ��'' ..p3r, Heat DR- Type RType Roof Rooms Ist Floor BR. Parch Recreation Roorr Rooms 2nd Floor FIN. B. Dormer Breezeway Driveway Garage I — -- Patio — -- O. B. --- — Total / Permit Number REScheck Compliance Certificate Checked By/Date New York State Energy Conservation Construction Code REScheckSoftware Version 3.5 Release Id Data filename: Untitled.rck PROJECT TITLE: REGAN RESIDENCE COUNTY: Suffolk STATE:New York HDD: 5750 CONSTRUCTION TYPE: Detached I or 2 Family HEATING TYPE:Non-Electric DATE: 09/10/03 COMPLIANCE: Passes Maximum UA=98 Your Home UA =82 16.3%Better Than Code(UA) Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA Ceiling 1: Flat Ceiling or Scissor Truss 390 30.0 0.0 14 Wall L Wood Frame, 16"o.c. 192 11.0 0.0 17 Wall 2: Wood Frame, 16"o.c. 144 11.0 0.0 13 Wall 3: Wood Frame, 16" o.c. 144 11.0 0.0 13 Wall 4: Wood Frame, 16" o.c. 192 11.0 0.0 14 Window 1: Wood Frame:Double Pane with Low-E 10 0.340 3 Window 2: Vinyl Frame:Double Pane with Low-E 10 0.340 3 Window 3: Wood Frame:Double Pane with Low-E 8 0.340 3 Window 4: Wood Frame:Double Pane with Low-E 4 0.340 1 Window 5: Wood Frame:Double Pane with Low-E 2 0.320 1 COMPLIANCE STATEMENT: The proposed building represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed systems have been designed to meet the New York State Energy Conservation Construction Code requirements. When a Registered Design Professional has stamped and signed this page,they are attesting thaatt to the best of his/her knowledge,belief;and professional judgment, such plans or specifications er in��J� stwith t� 7.�r7 s Code. Builder/Designer �,� Date F G�NE\ a�D G. 9 y0\ R e d h )n pR�FES510 k Chris Rehm Excavation & Drainage 390 Alois Lane Matti tuck, N.Y. 11952 Lr` CERTIFICATION OF SEWAGE DISPOSAL SYSTENI BY INSTALLER Health Department Reference Number: Suffolk Tax Map#: �- Dist: C-_-)_Sect(s):. _1 Blk(s):_z4Lot(s): 6 '7 Project Name or Address: J�to 17 6 G woo o L Al . - 6- Subdivision Name & Lot #: S o v T y o ) � t f 9 7 Applicant's Name: /7 ✓ it L f- 4 '1 y fi L 4 Description of System Installed: Septic "tank Volume (gallons): Shape: [] Rectangular [] Cylindrical Name of Precast Manufacture: Leaching Pools Number of Pools: Diameter and Depth: Other: Attach or Sketch below the measurements from the ing corners to the access covers of disposal system Sb� o N t,'' IN t'L S [ Ln/ fl- a v X u I hereby certify that the subsurface disposal system, described herein, has been installed by me in accordance with the approved plans and standards of the Suffolk County Department of Health Services; and is operational. Installer Signature ate: - Print Name/Company: is, i - - Phone: Consumer Affairs License Number: 1-,4 r This certification SHALL NOT be used in lieu or inspections required by personnel of the Department and may be duplicatc.i on company letterhead, provided it contains the above information. LINDA J.HAYES NotaryState of New York No.o. 01 O1 Q 822 Qualified In Suffolk Cou Plr Commission plr me 29, � rWA- 1- 40 /< - vo 'ONN'N OF SOUTHOLD BUILDING PERMIT APPI.ICAVION CHEC't�,I_IST ,I`I'LDING DEPARTMENT V Do you hate or need the followutg, before app CONN HALL Board of Health— �L�k ;OUT HOLD, NY 11971 ZTN 3 sets of Budding PlansTEL: (631) 765-1802 Plannine Board approsalFAS: (631) 765-9502 d SuneywNccv. northfork.net/Southold/ P � Cheek_ ___________ / Septic Form _-_ NN.S.D.E.0 Trustees I K Exanunzd It Contact: t�------ Approced 'u 3 flail to: L p 'V Disappro%edac____ n. 0 beh [50 e4Sn�TI,JL� Phone: —�- /M Expiration20 -- Building Inspector I!G 19 APPLICATION FOR BUILDING PERMIT /y e/0 3 --_. Date INSTRUCTIONS a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 3 sets of plans, accurate plot plan to scale. Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application, the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e. No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f Even building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within IS months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim, the Building Inspector may authorize, in writing, the extension of the permit for an addition six months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County, New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances, building code, housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. CD (Signature of or name a to por on1 Da 6 C,-JVol) /t (flailing address of applicant) XoV7"4v1- D/ w . L. . I f 7 State whether applicant s owner, ssee, agent, architect, engineer, general contractor, electrician, plumber or builder Name of owner of premises_ /� �✓[ ry L tel- �� y �(; {� �✓ (As on the tax roll or late§t deed) If applicant is a corporation, Srp azure of duly authorized officer N (Name and title of corporate officer) �i »a rvt G .rney SJ✓ ( hot i) t3 i. ctixnAa Builders License No._ 0 w-v tl- •t - e} t {g/ ,� 4 ! /� K e A Plumbers License No. /1t [ k l4_�7 0 ,� _ � p T T- t r 0 I< ^' Electricians License No. R q.✓ Cg � [£ - 1� ii �e i`7 G /✓ . �v T 7i o (4 Other Trade's License Na_' .J /< _ r 6 e _ Sc, T-{ t 0� -�J I . Location ofland on which proposed work will be done: -'4&6 House Number n 0 St etX / f 0 0 Han, et — f County Tax flap No. 1000 Section-- 3 Block V::�- � Lot Subdivision_ _ __Filed Map No. Lot (Name) -- � State existing use and occupancy of premises and intended use and occupancy of prop uuvction: _ a. Existing use and occupancy f� q nt 4 R b. Intended use and occupancy s! ^z < < 6 ('p I, i t- 5 14 • 14 t{ Nature of work (check which applicable): New Building Addition k"� _Alteration_ Repair _Removal Demolition_✓ 4 00 ( Other Work (Description) 1. Estimated Cost � (�u Fee �T (To be paid on tiling this application) If dwelling. number of dwelling units _Number of dwelling units on each floor If garage, number of cars i✓ o L ry 2 n 6 R 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. Dimensions of e fisting structures, if any: Front �� y+ 1'4 Rear f 4'0% f1k Depth Height / Z Number of Stories / Dimensions of same structure with alterations or additions: Front S� 'Li r Rear Depth S Q R Height 2. Number of Stories x. Dimensions of entire new construction: Front /f JF- Rear / o y Depth / a Height / Number of Stories 2- r r � 9. Size of lot. Front Rear /,0. }/ Depth 10. Date of Purchase 5/7 2 Name of Former Owner A < r r 1y t'� + r5 t4•c Sro w tt �✓c N 1 1 . Zone or use district in which premises are situated /'1 n Ifs-C t 0 t4 L 12. Does proposed construction violate any zoning law, ordinance or regulation? YES__ NO 11. Will lot be re-graded' YES_NO'Fill excess till be removed from premises? YES_ NO f 14. Names of Otener of'pre ises P -i- A7 15 Lf"-Address X a v h o r 0.,✓4hone No. ? L f' L C Name of Architect ° :- v i f< Address i z 4:o i. Phone No 7 L J- C / o L Name of Contractor hi ` L a At A Y Address D Phone No. ? G f— - C S v�k at0 v c,-rl, oL 0 1 S a. Is this property within 100 feet of a tidal wetland or a freshwater wet nd? *YES NO _ I/ * IF YES. SOUTHOL.D TOWN TRUSTEES & D.E.C. PERMITS MA'rI BE RFAU[RED. b. Is this property within 300 feet of a tidal wetland? * YES_ NO ✓_ * IF YES, D.E.C. PERMITS MAYBE REQUIRED. 16. Provide sun ey, to scale, with accurate foundation plan and distances to property lines. 1'. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. STATE OF NET YORK) c SS: COUNTYOFJ��F�'t)� Q 1 r?. L l-` 0�t being duly sworn, deposes and says that (s)he is the applicant (Name of individual sighing contract) above named, i S lHe is the (L� o .v T-� Aa e-- 7— o /k, — p ,,,- .W 6 (Contractor, Agent, Corporate Officer, etc.) of said owner or owners, and is duty authorized to perform or have performed the said work and to make and Cite this application; that all statements contained in this application are true to the best of his knowledge and belief: and that the work will be performed in the manner set forth in the application filed therewith. Sort to before me this � 7,da, of -CG -- -,009 Nota _ Publi Signature of Applicant LINDA J. Notary Public, State ateteof of New York No.. 01 01 HA6059822 Qualified In Suffolk Cour Commission Expires May 29, 20� -\� ,mjXTEi T. TERRY j Y 1 - ' n II,JI. S 11115 Alam I TOWN CLERKo = r O n- 117n IIEGISFRAR GF Mild, STATIST ICS .✓ ,Cb "'• A!ARRIAGr OFPICIiRFay iS I F'I lhc_I F21 Tcicph(InC l}Ih) 765- REcoftus WJ4AGEMENi OFFICER - 1 •-} I FREEDem OF INFORNtNTION OFFICER 'a OFFICE OF THE TOIA'N CI�ERK TOWN OF SOUTHOLD THIS IS TO CERTIFY THAT THE FOLLOWING RESOLUTION WAS ADOPTED BY THE SOUTHOLD TOWN BOARD AT A REGULAR MEETING HELD ON AUGUST 24, 1993 : RESOLVED that the Town Board of the Town of Southold hereby adopts two (2) new forms to be used under the Flood Damage Prevent regulations 1 of the Code of the Town of Southold : "Floodplain Development Permit t' pF,lil:-stinn" fFDP(93 ) 1 , an•1 "Certifi;_at,� of Cnmhliance tor- Development in Special Flood Hazard Area [C/C(93) ] . 114/ll i I f 6LEFT. TOVJN OF SO!PiOL9 ll�/ " Judith T . Terry ( Southold Town Clerk August 25 , 1993 • APPLICATION s PAGE I or a TOWN OF SOUTHOLD FLOODPLAIN DEVELOPMENT PEIIPT APPLICATION This Corm is to be filled out in duplicate. `SECTION L GENERAL PROVISIONS (a.PPLICAW to read and signl: L. No work may start until a permit is issued. 2- The permit may be revoked if any false statements are made herein. 3. If revoked, all work must cease until permit is rc-issued. 4. Development shall not be used or occupied until a Certifica[c of Compliance is issued. 5. The permit will expire if no work is commenced within six months of issuance- 6. Applicant is hereby informed that other permits may be required to fulfill local, state and federal regulatory requirements. 7. Applicant hereby gives consu=l to the Local Administrator or his/her representative to make reasonable inspections required to verify compliance. 8. I, THE APPLICANT, CERTIFY THAT ALL STATEMENTS HEREIN AND IN ATTACHMENTS TO THIS APPLICATION ARE,TO THE BEST OF MY �� DGE, TRUE AND ACCURATE. (APPLICANTS SIGNATURE) DATE SECCION 2: PROPOSED DEVELOPMENT (To be complcmd by APPLICAh'TI NAME ADDRESS TFLEPHONE APPLICA 4T BUILDER r .✓ c �-� o �� K .P;,�r� .�, 74f--6F' 1 ENGINEER ,/J� �I K 70, ao-r4olLo Pv `74S - I//O i PROJECT LOCATION: To avoid delay in processing the application, please provide enough information to easily identify the project location- Provide the street address, lot number or legal desorption (attach) and, outside urban areas, the distance to the nearest intersecting road or wcll-known landmark. A sketch attached to this application shoving the proirct lc-3600 would be hclpf 1. &o D 13(JAIf,+ L [Fun✓ — � nG U, po � G.19 FDP(93 ) APPLICATION PAGE '_ OF4 DESCR.IPFION OF WORK (Check all app6czb1c boxcs)- STRUCTURAL DEVELOPMENT ACT(VTT)' STRUCTURE TYPE= O New Structure (IdResidenual (1-4 Family) @!(Additio❑ ❑ Residential (More than 4 Family) D Alteration ❑ Non-residcnual (Floodproofmg? ❑ Yes) O Relocation ❑ Combined Usc (Resideuual &. Commerdal) ❑ DcmoGtion P ❑ Manufactured (Mobile) Home (In Manu- C1 Replacement factured Home Park? ❑ Yes) ESTIMATED COST OF PROJECTS 116 060 B. OTHER DEVELOPMENT ACTIVITIES: ❑ Fill ❑ Mining ❑ Drilling ❑Grading ❑ Excavation (Except for Structural Development Checked Above) ❑ Watercourse Alteration (Including Dredging and Chanel Modifica(ions) ❑ Drainage Improvements (Including Culvert Work) ❑ Road, Street or Bridge Construction ❑ Subdivision (New or Expansion) . ❑ Individual Plater or Scwer System y ❑ Other (Please Specify) Aftcr completing SECTION 2, APPLICANT should submit form to Local Administrator for review. SECTION 3FLOODPLAIN DETERMINATION (To be ccmplctcd by LOC?.L ADRfIMSTRATOR) The proposed devclopmc❑t is 1ccatcd on FIRh( Panel No Dated The Proposed Development: ❑ Is NOT located in a Special Flood Hazard Area (Notify the applicant that the application review is complete and NO FLOODPLAIN DEVELOP?,JENT PERMIT IS REQUIRED). ❑ Is located in a Special Flood Hazard Arca. FIRM zone designation is 100-'tear flood elevation at the site is: Ft. NGVD (MSL) U lloav"ablc ❑ The proposed development is located iu a Iloodway. FBFM Pancl No. Datcd .tee Section 4 for additional instructions SIGNED DATE .r • APPLICATION a PAGE 3 OF n SECTION 4 ADDITIONAL INFORMATION REOUIRED�To he completed by t Q_A ADMINISTRATORI The apphcani must submit the documents checked below before the apphcauon ran be processed. ❑ A site plan shovnng the locauon of all cxistMg slruaurc., wan-r h�dic, adlaccot roads, lot dimensions and proposed developmcm. ❑ Development plans, drawn to scale, and spc6ficatipns,including where applicable: details for anchoring structures, proposed clevatiun of lowest floor (including baacmcot), types of water resistant materia s used below the fast floor, details of Boodproofmg rf uuhties located below (be fust floor and details of enclosures below the first floor. Also ❑Subdivision or other development plans (If the subdivision or other development exceeds 50 lots or 5 acres,whichever is the lesser, the applicant must provide I00-year flood elevations if they are not otherwise available). • Plans showing the extent of watercourse relocation and/or landform alterations. ❑Top of new fill elevation Ft. NGVD (MSL). O Floodproofmg protection level (nun-residential only) Fl.NGVD (MSL). For floodproofed structures, applicant must attach certification from registered engineer or architect. ❑ Certification from a registered engineer that the proposed activity in a regulatory floodway will not result in any increase in the height of lbe 100-year flood. A copy of all data and calculations supporting this finding must also be submitted. Other: SECTION 5: PERMfT DETERMINATION (To be completed by LO AL ADPifN[STRgTORI I have determined that the proposed activity. A-O Is B. O Is not in conformance with provisions of Local law if 19_. The permit is issued subject to the conditions attached to and made part of this permit. SIGNED . DATF ff DQx -. is checked, the 1-Acal Administrator may i:suc a Development Pcrmit upon pa',imcot of designated fee. If BOK Bis check, the Local Admini;tralor u111 pro%idc a 'hTMeD summary of deCi6cncics. Applicant may revise and resubmit an application to the Loral Administrator or may request a bearing from (be Board of Appeals r APPLICATION a _ P.-.GE 4 OF 4 A.PPEALS Appealed to board Of Appcals7 ❑ Yes ❑ No Hcarmg date: ?.ppeals Board Decisioo --- Approved? n Ycs ❑ No Conditious SECTION 6: AS-BUILT ELEVATIONS fTo be submitted by APPLICANT before Certdicate of Compliance issued The following information must be provided for project st mctures. This section must be completed by a registered professional engineer or a licensed land surveyor (or attach a certification to this application). Complete I or 2 below. 1. Actual (As-Built) Elevation of the top of the lowest floor, including basement in Coastal High Hazard Areas, bottom of lowest structural member of the lowest Boor, excluding piling and columns) is: FT. NGVD (MSL). L Actual (As-Built) Elevation of Boodproofmg protection is FT. NGVD (N1SL). NOTE: Any work performed prior to submittal of the above information is at the risk of the Applicant. SECTION 7: COMPLIANCE ACTION (To be completed by LOCAL ADMIN[STRATORI The LOCAL. ADMINISTRATOR will complete tbis seaton as applicable based on Inspection of the project to ensure compliance with the commumvj} s local law for flood damage prevention. INSPECTIONS: DATE BY DEFICIENCIES? ❑ YES ❑ NO DATE_ BY DEFICIENCIES? ❑ YES ❑ NO DATE. BY DEFICLENCIES? ❑ YF--,S ❑ NO SECTION B: CERTIFICATE OF OMPLIAN E(To be completed by LO AL ADh1INISTRATOR) Certificate of Compliance issued: DATE BY: Attachment B SAMPLE CEF.TIFTCATE OF COMPLTA110E for Development in a Special Flood Hazard Area TOWN OF SOUTHOLD CERTIFICATE OF CONIPLIANCE FOR DEVELOPMENT IN A SPECIAL FLOOD HA7-AJM .kREA (OWNER MUST RETAIN THIS CERTIFICATE) PREMISES LOCATED AT: PERMIT NO. PERMIT DATE OWNERS NAME AND ADDRESS: CHECK ONE: 0 NEW BUILDING 0 EXISTING BUILDING 0 VACANT LAND THE LOCAL ADMINISTRATOR IS TO COMPLETE A. OR B. BELOW: A. COMPLIANCE IS HEREBY CERTIFIED WITH THE REQUIREMENTS OF LOCAL. LAW # 19 SIGNED: DATED: B. COMPLIANCE IS HEREBY CERTIFIED WITH THE REQUIREMENTS OF LOCAL LAW # 19_, AS MODIFIED BY VARIANCE # DATED SIGNED: DATED: CIC ( 93) L / 6L/ T d- lei A/T Regan Residence - 10, 31 ; 480 Dogwood Lane _."-- Southold, NY 11971 6e 7 - Fr (631) 765-6§96---- , I OFr Ge, YO Y Py 9C el44 1 6 Professional Engineer: - - - - - -- Ron Burk 145 Hickony Road FS, FOO�,p64 390 ss } ZL Southold, NY 11971 (631) 765-6102 39 0 Designer: Christian D. Giordano A1,7 6 2 South End Avenue (711) New York, NY i0280 CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA �� ix •co q p (1� 11 I GROUND! Wlnd SEISMIC SUBJECT TO DAMAGE FROM1.2 Winter h aided Y (212) 945-9020 SNOW DESIGN Frost line Design unment end LOAD SPEEDa ImpM1l LATEGORYe WeaImfig^ tlepihb Termitoe Oeca Tem , r fired zartlst� y Christian@cdgiordano.com H5 5- cs For51: 1pound per square too[=0smil kpa Imdcper Laurely then Mr �i n Wenadenngmay mgmrc nhlghering index he,tlem'gmdepfmaswmye"o necessary,tapetrify n...to.,deleralmp!requirements W.1hedwde.Thewwb,Me,column shall.2 tilled he grad the wwadmng index(i e, determined limn ASTM C"severe")for 2,C 7 ,vs 0,C 129, from adn WeoNering Probabibly Mop[Figure Rho 1.2(3)] The grade ofmasae d um6 Audi be determined Imm ASTM C34,C). C62,C etio 9h C illi C216 fmr rost line b The ffost hoe depth may fault require deeper footings Nan indicated in Figure 0.403.1(1).Thejunsdmhwn shall UII m the frost line depW column with the minimum depth of footing below finish grade c The 1 2(6)def n shall 611 m adts pan.1the moble with"very Imovg""moderate is heavy,""shghi m moderate;'or"none to shghi"in accordance wtN Figure 0.301 2(6)defending ll whether them hos been•but.,"mod of local damage d ThcJunsdrehon shall fill in adts porta[We mbiewnh"modcmte Iw severe;"'slight In mademte,"wr"none la slight"m o<cordnncewiW Ptgure 12301 2(7)depend- i h on whcader Isere hal anew o henary a tublol damage. e Tatedo aria-shell fill inis partararnlablewSechou R301peed tram the basic wind speed map[Figure 0.3012(9)] Windexposurecategoryshallhedemr- med on o silo-apccdic basis cordame arts Section 8301.2.1 A N I. ale 11 2 - db a aWm y g Thejudsdudum shad fill m Wis part of adn table with adc Seismic Dcsgn Qlagary determined from Section 13012.2 1 h Thin,onsdmnan shall fill in Up,pan urge table with(a)the rem mfdre,misdicimw'c envymto the National Flood lnsunnee Fosterer(date efidophon ofthe first code or ordinance for management of flood hewed aned,(b)the date(s)afthe currcndy effective PBM and FBFM,or other flood hazard map adopted by the camormanity,as may h mended uu Spe Flame R3012f5)for d no,lead, y i RESIDENTIAL CODE OF NEW YORK STATE 25 ll � I7l� Table 3.1 Nailing Schedule q�III Joint Ddocommn Numhemf Naik Nails . oenwlW7 (sre Trite 33A) per rafter �I R.Ra loTop Plole (T (see Table 33A) PerJom Cei:nm Joisl to Top Plate (Tac-miles) (see Table 37) each lisp Cat a, rest to Pualld RrRtr(Fas,molu3) (ss Table]) each lap Regan Residence Calm Tiu RaftLos over Pvrtl4ons (Face-nwlrxf) (xm Table-Ed34) Per tic JU.,hTmtoifter (Pvmnmlmp 2-Ed uch end Rim Bou m Rahu(locnmallo 2-16d mch end Rim Bawd to Rafter(Fnd-nailed) 480 Dogwood Lane . 2-16d' Per foal To,Plate b Top Plata (Farce-nailed) 4.16d jcots-wchside uthold NY 11971 �nalld) So we. Inters coons R 24^n t (631) 7656826 SIodP1.Smd ( mtmwl d, 16'oc along ad", Beedm m Bonder(Faso, ed) OF NEP/ 2-I6d Is 2x4 stud ,(E O G 1-� el,� To,.,Bottom PlvmmSWd (End.,410) }16d per 2x6 stud IP1PV e0 �,F 'i 416d per 2,8 sort 2-16du per foot # �� � '� � lollml l%nide mFlaarlol.tBmldjmeL End)ol9 orl1ovlang (Pausnvdrtl) m 7 2 x ili'i�"'JI Joislto Sill, Top Plateor Gudor (Tot-nwled) 2 8a Werja Ed h and ,� °li�i' !i�,�, lndging In Jmrl (Fee-nwl i) 2-Ed aoir end H? Blacken b 91l or'1'o W lots' nPent( ltd) 3-16d each block 0 g P (Toe 3-I6d will put �nw mtl Idgor Lo to Beam(P ace. ) 3 E pe lm4 Joist on Le 1.Joist Bramflm-nailulJ 3-16d Per JOI5 ' Bond Joan 1.Joip(Enbnwlttl) 2-16d' per fool Professional Engineer: I� Bond J..,toSri]orTo,Plate(focuwlW) Ron Burk s �I swcmmPnams ea eT m3 g) Dmal Board S Ed ""up. ort I" 6 .r 1".8" Per support145 Hickon Road 3-8d 1-1x10"in ander ld NY 11971 efx tho a Sou �4' sd coolers 7"edge/10"field 102 ,ant wwlhnad -6 c 1 765 , 63 'I 2P Ed re Tahle 3.9) ' 4 Slrvnuml PnneL d �helboaN Pands 3"Wal F Ed % ' 16" 6"field ]/ 3"clgc I Designer: '!I��'I ga 9 25132" "r d g e l Io"field Sd wolein ]Chr1stion D. Giordano DYPsum Wallboard 0d (.ec Table 39) I :1 Hwdbowd Ed (sen Tvhlc 3.91 2 South End Avenue (7H) Pvrtmishmed Panels p Ella6onW Boal Sheathing 2 E pan support 280 l"x6"or 1"x8" Support New York, NY 10 3 gd par= p 1 Jtr 1 xlO'or wl (21 )2 945-9020 , christian@cdgiordano.com Structural Pwmis 8d 6"alycl 12"field 1"mless lod 6"edge/6 field goner than F Diagonal load Sheuthin8 2-8d per support 1"x6"or 1"x8" 3-ed in, .....I Filo^or wider Nwhn b we hosed on wall shemltm6 coded 6'on center w the panel rdge ➢will sheathing¢nvdrd 3"oncemm�rt the panel edge g ln9m¢mrn mt forurainal members shall be doubled,ar alternate conmsalml such as she.Owes. In obtain kghc shmr mpvwties,vanImg¢qurtcin shall be uEd as maintain We bard peal themidared unions,of..Us shall be permit to he]educedan l-16d nwl per ' When wall shoalm cnnlinaaa.over-anedcl mm,,, foot AMERICAN WOOD COUNCIL 'ATION OF NAILING & CONNECTIONS ALL CONSTRUCTION SHALL REQUIRED. MEET THE REQUIREMENTS OF THE COMPLY VVITH ALL cODES OF CODES OF NEW YORK STATE. NE YORK STATE &TOWN CODES APPROVED AS NOTED AS REQUIRED AND CONDITIONS OF DIL— B.P.8-27 �'A'Q SOTHOLOTOWNm FE - Y By:—Z& NOTIFY BUILDING DEPARTMENT AT Regan Residence SOUTHOLDIDWRPLAI 765-1802 8 AM TO 4 PM FOR THE SOUTHOLDTOWNIRUSTES FOLLOWING INSPECTION& 1. FOUNDATION - TWO REOUIRED NY.S.DEC FORPOUREDOONCRETE 2 ROUGH - FRAMING & PLUMBING 480 Dogwood Lane �RCNIE 3' INSULATION 4. FINAL - CONSTRUCTION MUST PLUMBING REWRED BE COMPLETE FOR C.O. Southold, NY 11971 ALL PLUMBING WASTE ALL CONSTRUCTION SHALL MEET THE &,NATFR UNFS NEED REOUIREMENTS OF THE CODES OF NEW TESTING BEFOREco\IFRING YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. ADDITION AND RENOVATION PLUMBER CERTIFICATION ON LEAD CONTENT BEFORE OCCUPANCY OR CERTIFICATE OF OCCUPANCY USE IS UNLAWFUL SOLDER USED IN WATER WITHOUT CERTIFICATE SUPPL Y SYSTEM CANNOT AD. OF OCCUPANCY EXCEED 2/10 OF 1% LE noop ZONF, 4( I D iC(,K1PLY �N' H CHAPTER "46" Y/ FL ')CJD DAMA,-," P��t VENTION SOUTHULD I UVVN �ODE 12 IF ------ rLj L -A Lfirl 111114pij LOT: 07 OF� Nr�' BLOCK: 09 --------- SECTION: 54 FEE Professional Engineer: Designer: Ron Burk Christian D. Giordano 145 Hickony Road 2 South End Avenue (714) Southold, N-Y 11971 New York, NY 10280 (011) 765-6102 (212) 94.5-9020 ISSUED FOR PERMIT 08.01 .2003 GENERAL NOTES CHANGE IN WORK BUILDING DEPARTMENT GENERAL NOTES BUILDING DEPARTMENT NOTES FOR PLUMBING Regan Residence 1, THE CONTRACTOR, HIS SUBCONTRACTOR, AND ANY OTHER 1. THE OWNER WITHOUT INVALIDATING THE CONTRACT, MAY ORDER 1. GENERAL CONTRACTOR TO INCLUDE ALL PATCHING OF EXISTING 1. ALL PLUMBING WORK SHALL BE IN STRICT ACCORDANCE WITH 480 Dogwood Lane CONTRACTOR INVOLVED IN THIS PROJECT SHALL TAKE NOTE THAT EXTRA WORK OR MAKE CHANGES BY ALTERING, ADDING TO OR PLASTER SURFACES AS REQUIRED BY DEMOLITION AND NEW PLUMBING CODE OF N.Y. STATE 5/02 - SECTION 701-714. Southold, NY 11971 ANY COST CAUSED BY DEFECTIVE OR ILL-TIMED WORK, AS A DEDUCTING FROM THE WORK, THE CONTRACT" SUM BEING ADJUSTED CONSTRUCTION. RESULT OF, BUT NOT LIMITED TO INFERIOR WORKMANSHIP OR ACCORDINGLY. ALL SUCH WORK SHALL BE EXECUTED UNDER THE 2. CHANGES IN DIRECTION IN DRAINAGE PIPING SHALL BE MADE (G31) 765-6826 MATERIALS, IMPROPER SCHEDULING OR DELINQUENT ORDERING CONDITIONS OF THE ORIGINAL CONTRACT- EXCEPT THAT ANY CLAIM 2. ALL OUTSIDE CORNERS AT MASONRY AND DRYWALL PARTITIONS BY THE APPROPRIATE USE OF 45 DEGREE WYES, LONG SWEEPS: SHALL BE BORNE BY THE PARTY RESPONSIBLE THEREFORE. FOR EXTENSIONS OF TIME CAUSED THEREBY SHALL BE ADJUSTED AT SHORT SWEEPS, SIXTH, QUARTER, EIGHTH OR SIXTEENTH BENDS: 4- THE HAVE METAL CORNER BEADS TAPE AND SPACKLE SMOOTH e THE TIME OF ORDERING SUCH CHANGE. OR BY A COMBINATION OF THESE OR EQUIVALENT FITTINGS. �0 J ~ WHERE REQUIRED. a 2. THE USE OF THE WORDS "PROVIDE" OR "PROVIDED" IN w ° % CONNECTION WITH ANY ITEM SPECIFIED, IS INTENDED TO MEAN Z " a-? 2. IF THE GENERAL CONTRACTOR CLAIMS THAT ANY REVISIONS TO o UNLESS OTHERWISE NOTED, THAT SUCH SHALL BE FURNISHED, DRAWINGS INVOLVE EXTRA COST UNDER THIS CONTRACT, HE SHALL 3. ALL DEFECTIVE PLASTER AND/OR DRYWALL ON COLUMNS AND 3. SANITARY TEES AND QUARTER BENDS MAY BE USED IN INSTALLED, AND CONNECTED. GIVE THE TENANT WRITTEN NOTICE THEREOF WITHIN A REASONABLE EXISTING WALLS SHALL BE CHOPPED OUT AND/OR PATCHED FREE DRAINAGE LINES ONLY WHERE THE DIRECTION OF FLOW IS FROM rdtioy oQ. THE HORIZONTAL TO THE VERTICAL. TIME AFTER RECEIPT OF SUCH INSTRUCTIOIN, IN ANY EVENT BEFORE OF ALL IRREGULARITIES AND SHALL MATCH ADJACENT WALLS IN 3. THE CONTRACTOR SHALL SUPPLY CUTS OF ALL FIXTURES AND PROCEEDING TO EXECUTE THE WORK AND THE PROCEDURE SHALL THEN FINISH AND THICKNESS. Professional ngineer: EQUIPMENT CALLED FOR ON DRAWINGS, I.E., LIGHT FIXTURE, BE A PROVIDED FOR IN THE CHANGES IN THE WORK. NO SUCH CLAIMS 4. SHORT SWEEPS WILL BE PERMITTED IN DRAINAGE PIPING 3 IN, Ron Burk HARDWARE, ETC. SHALL BE VALID UNLESS SO MADE. UNLESS OTHERWISE AGREED, NO DIAMETER OR LARGER FOR ANY OFFSETS EITHER HORIZONTAL OR 4. ALIGNMENT OF NEW DRYWALL CONSTRUCTION TO EXISTING 145 Iliekon PAYMENT ON SUCH BILLS WILL BE MADE UNTIL FINAL SETTLEMENT. VERTICALy Road . WALLS AND COLUMNS SHALL BE DONE IN A MANNER AS TO VISIBLY Southold, NY 11971 4. THE CONTRACTOR SHALL MAINTAIN A CURRENT AND COMPLETE ELIMINATE THE POINT OF CONTACT OR JOINT TO NEW AND SET OF CONSTRUCTION DRAWINGS ON SITE DURING ALL PHASES EXISTING MATERIALS (RUN OUTSIDE LAYER OF SHEETROCK PAST (631) 765-6102 OF CONSTRUCTION FOR USE OF ALL TRADES. 3. ALL CLAIMS FOR ADDITIONAL WORK WILL BE SUBMITTED IN WRITING COLUMN WHERE POSSIBLE TO AVOID THIS CONDITION). FOR APPROVAL OF THE TENANT AND SHOULD INCLUDE A COMPLETE 5. ALL EXISTING APPURTENANCES NOT BEING REMOVED SHALL BE DESCRIPTION OF THE WORK BEING PERFORMED, MATERIALS BEING Designer: REFURBISHED WHERE REQUIRED, ANY LOOSE ITEMS TIGHTENED USED, THE CONSTRUCTION SPACE NUMBER OF THE AREA BEING 5. ALL EXISTING BASEBOARD SHALL BE REMOVED, WALLS PATCHED AND ANY MISSING PARTS REPLACED BY THE CONTRACTOR TO WORKED IN, AND THE AUTHORIZATION UNDER WHICH THE WORK IS AS REQUIRED AND BASE REPLACED WITH NEW BASE, UNLESS Christian D. Giordano ACHIEVE A FINISHED FIRST CLASS INSTALLATION AND BEING PERFORMED. OTHERWISE NOTED. 2 South End Avenue (711) APPEARANCE. New York, NY 10280 6. ALL DEFECTIVE PLASTER OR DRYWALL CORNER BEADS SHALL BE - _- (212) 945-9020 6. CONTRACTOR IS TO EMPTY ALL PLUMBING LINES NOT ITEMS SUBJECT TO CONTROLLED INSPECTIONS REMOVED AND REPLACED WITH NEW. christian(wedgiordano.com NECESSARY FOR NEW WORK AT THE MAINLINE. 1. MECHANICAL VENTILATION PER LOCAL CODES. 7. THE CONTRACTOR SHALL KEEP THE PREMISES FREE FROM 7. ALL REQUIRED EXITS, WAY OF APPROACH THERETO, AND WAY OF ACCUMULATION OF WASTE MATERIAL AND RUBBISH INCLUDING \ TRAVEL FROM THE EXIT INTO THE STREET SHALL CONTINUOUSLY 2. STRUCTURAL STABILITY-DEPT. RULES & REG. N.Y. STATE BLDG. CODE CARPET SCRAPS, AND AT THE COMPLETION OF THE WORK HE SHALL \ BE MAINTAINED FREE FROM ALL OBSTRUCTIONS AND IMPEDIMENTS REMOVE ALL DEBRIS. PREMISES ARE TO BE LEFT BROOM-SWEPT - Revisions: FOR UNOBSTRUCTED EGRESS IN THE CASE OF FIRE OR OTHER 3. FINAL INSPECTION PER DIRECTIVE OF LOCAL CODES. CLEAN AT THE END OF EACH WORKING DAY. No Date: Description EMERGENCY. � 4. ALL IN ACCORDANCE WITH N.Y. STATE BUILDING CODE 5/02. 8. THE CONTRACTOR SHALL PROVIDE REPRODUCIBLE "AS BUILT' PLOT PLAN DRAWINGS, IN A FORMAT ACCEPTABLE TO THE BUILDING OWNER, USE AND OCCUPANCY CLASSIFICATION SHOWING ALL LIGHTING AND ELECTRICAL CIRCUITING WORK ; (INCLUDING CIRCUIT NUMBERS) AS ACTUALLY INSTALLED. Al - ONE FAMAILY DWELLING 9. CONTRACTOR SHALL VERIFY DIMENSIONS AND FIELD CONDITIONS, NOTIFY THE ARCHITECT OF ANY DISCREPANCIES IN TYPE OF CONSTRUCTION _ CONTRACT DOCUMENTS, AND OBTAIN CLARIFICATION BEFORE AVE PROCEEDING WITH WORK AFFECTED BY THE DISCREPANCIES. TYPE 5 - FRAME CONSTRUCTION6��4pla 10. FOLLOW FIGURED DIMENSIONS, AND DO NOT SCALE CONTRACT -_ DRAWINGS. - Key: SQUARE FOOTAGE: _- - - 11. PROVIDE TEMPORARY MARKERS FOR LINES AND LEVELS FOR USE BY ALL TRADES. NEW 1 ST FLOOR SQUARE FOOTAGE: 34 SQ.FT. 12. ARCHITECTURAL DRAWINGS SHALL GOVERN OVER ENGINEERING NEW 2ND FLOOR SQUARE FOOTAGE: 390 ISQ.FT. DRAWINGS FOR LOCATIONS OF LIGHTING, ELECTRIC AND TELEPHONE OUTLETS, DATA OUTLETS, CEILING DIFFUSERS, LIGHT TOTAL SQUARE FOOTAGE: 1530 !SQ.FT. FIXTURES, ETC. '} 13. WHERE SHELVES OR CASEWORK EXTEND TO CEILING, NEW BUILDING F4E'IGHT: = T� _`-ISI i4 COORDINATE LOCATION OF ADJACENT CEILING REGISTERS, - DIFFUSERS AND FIXTURES. NEW RIDGE HEIGHT: 20'-10" DRAWING LIST MAXIMUM TRAVEL DISTANCE: LOT: 07 09 1 - COVER SHEET 14 -0' Seal: 2 - T-1: GENERAL NOTES , BDG DEPT NOTES, DRAWING LIST, PLOT PLAN 3 T 2: SYMBOLS LEGEND, MATERIAL ID, ADAPTIVE BATHROOM DIAGR,\MS j/ / O G 4 - D-101: DEMOLITION & REMOVAL PLAN C SOF NELV } 5 - D-102: DEMOLITION & REMOVAL ELEVATIONS 14P411 LJ y o 6 - A-101: CONSTRUCTION PLANS x'6,. 4`'!.° 1I 7 - A-102: EXTERIOR ELEVATIONS 8 - A-103: ROOF PLAN, BUILDING BECKONS, & DETAILS -AREA OPWORK 9 - A-104: WINDOW SCHEDULE, DOOR SCHEDULE & PLUMBING RISER DIAGRAM I _ I � I 10- A-105: WINDOW & DOOR DETAILS ----------------------------- Ll ------ - ' - - Vi i Drawing Title: / GENERAL NOTES, BDG DEPT NOTES, - DRAWING LIST, PLOT PLAN N LOT: 07 -- - - Scale: --ASNOTED Drawing No: BLOCK: 09 Date: 08 _onu Project No oovua T-1 Drawn By: Gnd -- Regan Residence SYMBOL LEGEND MATERIAL INDICATION 450 Dogwood Labe Southold, NY 11971 -- (631) 765-6826 SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION D FINISHED WOOD o ACOUSTIC TILE ROOM NAME ROOM ID % DETAIL INDICATOR 0 NEW PARTITION 4 WALL SCONCE 0 ROUGH WOOD BLOCKING a CERAMIC TILE TYPE-1 X-1^23 -lyP X'-%"AFF XDETAIL LABEL xiz3z vP ELEVATION / SECTION ID — _ _ _ _ DEMO PARTITION W WALL MTD. DUPLEX 0 MARBLE OR GRANITE o RESILIANT TILE X" - I.-a,.DETAI _ 0 FLEXIBLE/SOUND INSUL. PLASTIC LAMINATE Professional Engineer: NEW MILLWORK WALL MTD. DUPLEX - GFI Ron Burk DETAIL BUBBLE a 3 z FOUR WAY ELEVATION ID �GFI sHr 145 IIickony Road D RIGID INSULATION D CONCRETE - - - - - - Southold, NY 11971 0 DOOR ID I�EvnnoN ELEVATION MARK ® SMOKE DETECTOR RCP WALL MTD. QUAD (631) 765-6102 x'-x" D SEALANTS CARPET & PAD WINDOW ID TARGET/ STARTING POINT sP STARTING POINT - RCP ry X'-X"AFF WALL MTD. CABLE TV Designer' A-i � � o GYPSUM WALL BOARD 0 RIGID INSULATION Christian D. Giordano O CL CENTER LINE F-i FLOOR FINISH <J WALL MTD. DATA 2 South End Avenue (7H)A PARTITION ID X'-X"AFF 0 PLYWOOD o STONE New York, NY 10280 (212) 945-9020 REVISION NUMBER WALL FINISH WALL MTD. TELEPHONE o GLASS o METAL christian(g-cdgiordano.com P-i X'-X"ARE Revisions: 3G„ No. Date: Description: BACK MIN, MAX J � CONTROL AREA w _ MIRROR — 17' MIN -- -- -Ir------- CLEAR FLOOR SPACE z Key: r r N i M MAX.19 4�4' l� TOE CLEARANCE 48" MIN MIN MAX. SHOWER HEAD AND CONTROL AREA MAY BE ON BACK WALL (AS SHOWN) OR ON EITHER SIDE 17" MIN. 3fi IN, BY 36 IN. STALL I _ N1 [Q-14 lul LAV DEPTH -------- �l SIDE ELEVATION PLAN SEAT WALL BACK WALL CONTROL WALL PLAN - _I LAVATORY CLEARCES C2 )!OTHOWER STALL IN ADAPTABLE BATHROOMS LOT: 07 BLOCK: 09 TO SCALE NOT TO SCALE Seal: pF NEW r P PYD G. BV0 4a .Iii' (i 36 MAX 12 12� 24" CL 24„ 6' 42" 8,. a 12 42 MIN MIN MAX MAX MIN. CONTROL AREA 15' TOILET PAPER - m z MAX = z m � SHADED AREAS ARE REINFORCED TO RECEIVE GRAB BARS Drawing Title: SHADED AREAS ARE REINFORCED TO RECEIVE GRAB BARS SYMBOLS LEGEND, MATERIAL ID., FOOT BACK HEAD ADAPTIVE BATHROOM DIAGRAMS SIDE ELEVATION FRONT ELEVATION Scale: AKOTE, Drawing No: WATER CLOSET INADAPTABLE BATHROOMS OBATH TUBS INADAPTABLE BATHROOMS Date: us - 3 -- NOT TO SCALE Project No: otiT-2 NO oS — NOT TO SCALE Drawn By: one DEMOLITION NOTES 3q2 Regan Residence ---------------------------------------- 480 Dogwood Lane 1 . THE CONTRACTOR SHALL FURNISH ALL LABOR AND MATERIALS AS REQUIRED TO COMPLETE DEMOLITION AND REMOVAL OF ALL ITEMS AS SHOWN Southold, NY 1171 OR NOTED ON DRAWINGS, IN AT NEAT AND SYSTEMATIC MANNER 11 (631) 765-6826 I I I I 2. THE CONTRACTOR SHALL SUBMIT HIS PROPOSAL BASED ON EXECUTING I I I ALL WORK WITHIN THE REGULATIONS OF THE BUILDING FOR DEMOLITION AND ---" '--'--""'-'--'--- 1 REMOVAL OF DEBRIS: ALL DEMOLITION WORK AND RUBBISH REMOVAL SHALL I _ 1 � I BE DONE AS SPECIFIED BY BY LOCAL CODES. ,1i 11 o II II I I II p I I II II 3. THE CONTRACTOR SHALL FURNISH A SYSTEM OF TEMPORARY LIGHT THROUGHOUT THE SPACE UNDER CONSTRUCTION, IF REQUIRED. """-"'-""---"' � Professional Engineer: II I 4 THE CONTRACTOR SHALL CAP AND FLUSH OFF BEHIND FINISH ;r----- Ron Burk -------- 1 `----------JI SURFACES ALL PROJECTING PLUMBING, FLOOR ELECTRICAL/TELEPHONE - ' --_____---- I 145 Hickony Road KNEE WALL HT. ii STORAGE Southold, NY 11971 OUTLETS, AND ALL OTHER PROJECTING ITEMS WHICH ARE BEING 3`8„ ii (631) 765-6102 ABANDONED. DEMO & REMOVE STAIR ROOF BELOW 1 5. NO STRUCTURAL ELEMENTS SHALL BE REMOVED UNLESS THE PORTIONS r----------------------------- =-------------------- -------ti 1n Designer: AFFECTED ARE ADEQUATELY SUPPORTED BY EITHER TEMPORARY SHORING OR / a V III cEILiNG Hr. DEMO M REMOVE NEW STRUCTURAL ELEMENTS AS REQUIRED TO PROTECT THE STABILITY AND D-io2 Ilii 6'-10" i� Daces 2 - 1 L---- , , DN ,111 D-,oz Christian D. Giordano 01— --------------------- - --- ------ nr2rr==_=701 1 r"F-----y IIIIIL INTEGRITY OF THE EXISTING STRUCTURE , ,h�---- 11 2 South End Avenue (7H) BEDROOM New York, NY 10280 6. THE CONTRACTOR IS TO VERIFY LOCATION OF ALL UTILITY LINES, " n,1 SHUTOFFS, VALVES, ETC. PRIOR TO START OF DEMOLITION. nL iiirIr---- (212) 945-9020 1i l i ii 11 ---- _J_L_ christian@cdgiordano.com 7. THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING NEW PLUMBING LINE "� r------------------- 5 r--------- -� 1 1r__________________________ 1 IF �_______� JI IL_____JI III LOCATIONS AND SPECIFICATIONS WITH EXISTING AND PROPOSED PLUMBING ------ ---- Iii 11 AND BUILDING INFRASTRUCTURE. o Revisions: II I 8. ALL UNUSED AND REMOVED GAS AND PLUMBING LINES TO BE II DEMO & REMOVE I1 No. Date: Description: PROPERTY CAPPED AS REQ'D. BY NYC BLDG. DEPT, CODES. PARTITIONo P 11 I1 NO WORK IN �� 0 THIS AREA 1 U II L________________________________________________________________ IJI DEMO & REMOVE EXISTING ROOF 2nd FLOOR DEMO PLAN D-i o2 /4„ _ D„ Key: SYMBOL LEGEND -- _ D-iD2 — STORAGE SYMBOL DESCRIPTION wooDDecK ® - 0 EXISTING PARTITION T 7M. ��LU L— LOT: 07 --------- I � L_________ STORAGE THDEMO PARTITION BLOCK 09 OV I SINK �� I �� TUB III'' 0i I� �I NO WORK IN THIS AREA � Daer DN 11MAS7ER Seal: DINNING KITCHENREF' CLOSETCLBATH --' D-102 E _.___ HEADER HT. HEADER HT- ;/ a a. CEILING HT. C `o1,� 6'-11 1/2" - -_--_ DEMO & REMOVE __ --------------- w --------------------- _-- - — MASTER BEDROOM rmsF f1la STAIR n� DEMO & REMOVE ENTRY u�---- BEDROOM .— DOOR AND FRAME� 1 ------------------------------ _____ ______________ yt____ 1 R- CL. ' CL. - n c= _ LIVING ii 'rJ-- -- KNEE WALL HT. OA1 1 1 6,-3„ 1 II 1 I I EXIST. CEILING HT. L_� 'F___L_1_____ NO WORK IN 1 1 THIS AREA I 1 I 1 Drawing Title: - --- ---=== DEMO & REMOVE POST DN DEMOLITION & (BRACE AS REO'O) DEMO & REMOVE DEMO & RCMOVE IL______J ExsnNc wmpaw PARTITION 111 1 REMOVAL PLAN (HEADER TO REMAIN) (BRACE AS REO'D) TIF-------'1� DEMO & REMOVE STAIR 111 1st FLOOR DEMO PLAN ______ 1 AND STAIR FOOTINGS A5 iii ; AEq'D Scale: ,,, - r_o^ Drawing No: 2 L______J Date: 08-01-11003 ,/4° uD-101 O-iD2 Project No: u000s Drawn By: CDC, Regan Residence 480 Dogwood Lane Southold, NY 11971 (631) 765-6826 T.O. CHIMNEY CHIMNEY TOP TO BE i i r-� CHIMNEY TOP TO BE 19'-0 1/2" RELOCATED AS REO'O, RELOCATED AS REq'D _- - EXISTING ELECTRIC FROM ROOF RIDGE ______ -------_ STREET TO REMAIN VENT TO DE RELOCATED a 17'-01/2" a DEMO & REMOVE WINDOW Professional Engineer: RIDGE LINE TO BE - a Ron Burk RELOCATED As resD'D _=_'__ a 145 Hickony Road -- �~ ° Southold NY 11971 NO WOR IN rr=====;i�� AREA (631) 7656102 ROOF RIDGE L�----� a0 ROOF RIDGE THIS 10'_7° . 10'-7" a 2nd FLOOR --- _ _ ______________ ____ __-__ ___ _ -�_ __—___ ,a Designer: NO WORK IN ___ ______________________ THIS AREA 8-6 _ __ Christian D. Giordano r___________________ II r________ r__--_�r �r___--��--E r--_____� _ 2 South End Avenue (7H) rFX X IL---------- 'i E_==----- ROOF RIDGE New York, NY 10280 II ZIEL OL �I II II I� J L{I � X II Ir__________ II L________ ._ Ir__________ � ._ — II II II IL _ --I FSI IP X 111rII F________ __ - II I�=— gllly ,IIIE====-____= 0 — $ r=====___ - -- -- (212) 945 9020 4'-9 1 2" �- E J, TO --------- �e �ii� - E -- __-- — --- christiancued iordano.coln L _JL _JL _J� ] r. Lac Y 9JIL L.—' n IF---------- DEMO & REMOVE _ g IF---------- _ L________ __.--_ - -L_ J L= STAIR & RAIL .' Ji ______________ I��f 111 _ JI II IL______ l 1st FLOOR _—JYc� k==_� ______ _ _ __ _______._ _________________ 1 OFLOOR • it Jll�r________ __ ______________ �}- __________________ ________________ ll' �� 1 7 n ___________ T- 0 1_0 " cv=¢a' FA ; FLOOR Revisions: pon�aao EXISTING GRADE II E_d II II —� " 2'-1r' Il�cvzmvc - 2'-51/2" II p- I I i � _ No. Date: Description: EXISTING GRADE EXISTING GRADE I L__ ----- - EXISTING GRADE DEMO & REMOVE DEMO & REMOVE DEMO & REMOVE J DEMO & REMOVE SIDING WINDOW STAIR AND STAIR SIDING FOOTINGS As ELEC. TO REMAIN REO'D FRONT ELEVATION DEMO � RIGHT SIDE ELEVATION DEMO SYMBOL LEGEND Key: SYMBOL DESCRIPTION DEMO AREA NO WORK IN THIS AREA CHIMNEY TOP TO BE - Ir-rl CHIMNEY TOP TO HE r-, RELOCATED As REO'D T.O. CHIMNEY — - r--I T.O. CHIMNEY 19'-0 1/2" RELOCATED As AEgb 19'-0 1/2" LOT: 07 __ _______________ _ ROOF RIDGE VENT TO BE RELOCATED ROOF RIDGE 17'-0 1/2" 0 17'-0 1/2" BLOCK: 09 DEMO & REMOVE REAR RC NO WORK IN OF DEMO & REMOVE WINDOW E-3 I I —Jseal 9 I I sell Seal: THIS AREA i i ROOF RIDGE ! i ' I I _ _ :77-:-;:: 2nd FLOOR 2nd FLOOR _ _ DEMO REMOVE GUTTER _ E111TING DESK TO REMAIN �lil DEMO & REMOVE STAIR & RAIL N 0 1st FLOOR it 1st FLOOR s. FLOOR GRADE Ili =q it - 2'-11" EXISTING GRADE E - 3'-1 1/Y' - 2'-10.. EXISTING A.C. UNIT _ Drawing Title: DEMOLITION & REAR ELEVATION DEMO O LEFT SIDE ELEVATION DEMO REMOVAL ELEVATIONS 34 , _D ' = ' " / Scale: ,,, _ �.0. Drawing No: ----- Date: OSTDI 2003 Project No: Omnis D-102 Drawn By: GDG CONSTRUCTION NOTES FINISH NOTES ^ °z r--------------------------------------- Regan Residence 1 THE CONTRACTOR SHALL DO ALL CUTTING, FITTING AND PATCHING 1 . PAINT COLORS SHALL BE SPECIFIED BY OWNER AND THE GENERAL DoN Lane SoUth0ld, N WORK THAT MAY BE REQUIRED TO MAKE ALL PARTS COME TOGETHER CONTRACTOR SHALL SUBMIT SAMPLES FOR APPROVAL BY OWNER. Y 11971 PROPERLY, AND FIT TO RECEIVE OR BE RECEIVED BY WORK OF OTHER (631) 765-6826 I I CONTRACTORS SHOW UPON OR REASONABLY IMPLIED BY THE DRAWINGS 2. ALL WALLS AND CEILINGS SHALL BE PROPERLY PREPARED, SPACKLED, AND NOTES SANDED, ETC., TO PROVIDE A PERFECTLY SMOOTH FINISH AND SURFACE A-3 A-3 A-4 r-11 1/2" ALIGN (2) 2x8 (2) 2x8 (2) 2x8 2. THE CONTRACTOR SHALL PROVIDE ALL FLOOR CUT-OUTS AND 3. THE CONTRACTOR SHALL, UPON COMPLETION, REMOVE ALL PAINT FROM _ PATCHING REQUIRED FOR THE INSTALLATION OF ALL WORK. WHERE IT HAS SPILLED, SPLASHED OR SPLATTERED ON SURFACES, 2'-0" 2'-N' DO ro 0 11 INCLUDING LIGHT FIXTURES, DIFFUSERS AND REGISTERS, SLAB FITTINGS, � CENTER-LINE OF ROOM __I TUB 3. THE CONTRACTOR SHALL SURVEY ALL EXISTING FINISHED SURFACES TO ETC. HE SHALL REMOVE ALL ELECTRICAL SWITCH PLATES AND OUTLET NEW T_'BEDROOM INCLUDE CORNER BEADS, STOPS, ETC FOR CHIPS, CRACKS, HOLES, AND PLATES, SURFACE HARDWARE, ETC. BEFORE PAINTING, PROTECTING AND 4z M. BATH DAMAGED SURFACES, AND ANY OTHER DEFECTS CAUSING AN APPEARANCE REPLACING SAME WHEN PAINTING HAS BEEN COMPLETED. 6 I Q - DIFFERENT FROM A NEW FIRST CLASS FINISHED INSTALLATION. THESE __# NEW SHELVES DEFECTIVE SURFACES SHALL BE REPAIRED, OR IF BEYOND REPAIRING, 4. THE CONTRACTORS SHALL PROPERLY PREPARE ALL SURFACES TO w NEW MARBLE SADDLE� Professional Engineer: THEN THE GENERAL CONTRACTOR SHALL REMOVE ALL EXISTING AND RECEIVE ONE (1) PRIME COAT AND TWO (2) FINISH COATS OF PAINT IN LINE OF ry �I NEW TILE 4 tins Ron Burk ROOF ABOVE = '2 - INSTALL NEW SURFACES TO THE SATISFACTION OF ARCHITECT & OWNER COLOR SELECTED BY ARCHITECT. 145 Hickony Road 4. ALL OTHER DAMAGED SURFACES INDUCTION UNIT ENCLOSURES, ETC. 5 ALL EXISTING LOOSE PAINT SHALL BE REMOVED AND SPACKLED OR 030 ; Southold, NY 11971 HT. CEILING SD ROOF BELOW SHALL BE REPAIRED TO THE SATISFACTION OF ARCHITECT & OWNER. PLASTER PATCHED. O > (631) 765-6102 B'-0" a'-a -O" 5. THE CONTRACTOR SHALL INSPECT ALL EXISTING PLASTER OR GYPSUM 6. ALL EXISTING UNEVENNESS IN ALL PARTITIONS SHALL BE SANDED OROlt- BOARD SURFACES AND WHERE, AS A RESULT OF DEMOLITION, FINISHED CHIPPED AWAY AND SURFACES PLASTER-PATCHED OR SPACKLED TO q UNE OF FLAT °NE m SURFACES DO NOT ALIGN, THE EXISTING PLASTER OR GYPSUM BOARD INSURE A PERFECTLY EVEN SURFACE A-1oz CEwnc cam. A_6 A-1 D2 Designer: SHALL BE CHOPPED AWAY. NEW CORNER BEADS AND STOPS INSTALLED SEEI'DEC IER a/A-ma Christian D. Giordano ---FOR'CIFOSEt,--- ----i -- NEW STAIR AND SURFACE REPLASTERED TO A SMOOTH, FLUSH, ALIGNED SURFACE. 7. THE PAINTING CONTRACTOR SHALL INCLUDE SEMI-GLOSS PAINTING ON w 2 South End Avenue 7H) ALL SHOP-PRIMED WOODWORK IN HIS WORK, AS INNEW SHELF AND (SEE 2/A-I03) (DICATED ON DETAILS a New York, NY 10280 6. ALL DAMAGED AREAS AFFECTED BY DEMOLITION OR NEW CONSTRUCTION CONCERNED. POLE ( P o WORK SHALL BE REPAIRED OR PATCHED AS REQUIRED TO MATCH (212) 945-9020 A"6 CENTER-UNE OF ROOM IMMEDIATE ADJACENT AREAS IN MATERIAL, FIRE RATING, FINISH AND 8 THE CONTRACTOR SHALL EXAMINE ALL AREAS OF CONSTRUCTION AFTER _ qP christian@cdgiordano.com COLOUR, UNLESS OTHERWISE NOTED, WITHOUT ADDITIONAL COST TO THE COMPLETION OF WORK BY ALL TRADES (INCLUDING TELEPHONE (2) 2x0 OWNER. INSTALLATION, FLOORING, ETC.) AND APPROVE ALL NECESSARY "TOUCH-U" N" --- - ---------------- ------------------------------------------ 7. THE GENERAL CONTRACTOR SHALL PROVIDE ALL LING AND GRADE PAINTING AND/OR PATCHING. (/ SOFFIT SPACE MARKINGS ON THE FINISH FLOOR OF ALL PARTITIONS FOR ARCHITECTS 9. ALL WORKMANSHIP SHALL BE OF THE BEST QUALITY AND WHEN THE (UNUSABLE NO NDRevisions: APPROVAL PRIOR TO ERECTION OF PARTITION STUDS. WORK IS COMPLETE, IT SHALL BE FREE FROM BUCKLES, BUBBLES, OPEN IS AREA JOINTS OR OTHER IMPERFECTIONS. SEAMS SHALL BE KEPT IN ACCURATE NOTE 1No. Date: Description: : 8. THE GENERAL CONTRACTOR SHALL USE CORNER BEADS TAPE SPACKLE ALIGNMENT ALONG BOTH COORDINATES. ❑ ❑ ALL BATHROOMS AND SHOWERS TO RECEIVE TILE FINISH SHALL AT ALL EXPOSED CORNERS AND EXPOSED ENDS IN PLASTER AND DRYWALL HAVE 5/8" GREEN BOARD AS FINISH ON WET SIDE OF PARTITIONS. 10. UPON COMPLETION, ALL WORK SHALL BE CLEANED BY THE PARTITION IN WET LOCATION IN LIEU OF GYPSUM BOARD-TYP CONTRACTOR, REMOVING ALL SPOTS OF ADHESIVE AND SURFACE STAINS LINE of 9. ALL PARTITIONS SHALL BE ANCHORED FIRMLY AS PER MANUFACTURER'S AND ALL SCRAPS, CARTONS AND CONTAINERS SHALL BE REMOVED FROM ROOF ABOVE ❑ ❑ NOTE 2: SPECIFICATIONS. THE BUILDING. 2nd FLOOR CONSTRUC ION PLAN ALL LUMBER TO BE DOUGLAS FIR #2&BTR OR BETTER 10. ALL CONSTRUCTION FRAMING IN ACCORDANCE WITH N.Y. STATE BLDG. /4" =1 '-0" NOTE 3: CODE SECTION 1609 & RESIDENTIAL CODE R 301 .2 HURRICANE REGION. B a ALL VERTICAL PARTITIONS TO BE 2X4 WALL STUDS A-103 A-10,7 A-103 A-ID2 NOTE 4 DESIGN LOADS IN ACCORDANCE WITH ASCE-7. NOTE 5 SYMBOL LEGEND GLAZED OPENINGS IN ACCORDANCE WITH LMT (BY MISSILE TEST) Key: AND ASTM E 1996 SYMBOL DESCRIPTION ] 0 EXISTING PARTITION a-1 D2 I 1 WOOD DECK STORAGE - — I D NEW PARTITION (2) 2xla IJI (2) 2x10 NEW MILLWORK _ - __ STORAGE T - - LOT: 07 I M. BATH ov sT�K NB i BLOCK: 09 d� I I - — STRUCTURAL NOTE oT� ON OILEf so SMOKE DETECTOR DINNING KITCHEN RrdF. ! MASTER CLOSET - Seal: LL m CEILING HT. BATH 2 4 8'-0" �— A-102 NO WORK IN THIS AREA A-102 / I SOFFIT HT. CEILING HT. - --I - 2- 2x12 -------6'-11 1/2" - NEw STwR --- --- -- - MASTER BEDROOM ¢2Ry �(_----� ) L2) 2x12 6 SEE DOOR AND WINDOW SCHEDULE ON SHEET A-104 s 2/A-1Ga) _ VII 1p' _--__-_______._--__-------- --------- CEILING HT. BEDROOM � • 6=0 EXISTING e m _ Of �pPe SD m CL. - LIVING `a KNEE WALL HT. . PATCH & REPAIR -- 6'-3" - EXISTING r _ FLOOR AS REO'D \" _ AT CN C' PARCH & REPAIR NEW " PARTITION __ \ NO WORK IN � ']- 01 UP R @ 8 1/ THIS AREA —NEW PARTITION (2) 2x10 (2) 2x10 (2) 2x10 '1 j (2) 2x10 NEW WOOD RAIL TO _ COMPLY WITH ALL OEo ED O _ O LOCAL CODES Drawing Title: A-1 A-1 ALIGN A-2 I'-I I" _ (ANCHOR AS BEGS.) P - q" POSTS CONSTRUCTION PLANS 0'-4 I/T ED PATCH & REPAIR EO n (ANCHOR AS REO'D) NEW PAR ITION CL PATCH CONCRETE PORCH & NEW MTL 5ADOLE REPLACE BRICK EDGE TRIM _ NEW CDNCRFTE STEPS Scale: 14 - -W Drawing No: WITH BRICK EDGE TRIM 9'-0 1/2" L _ -- 1 st FLOOR CONSTRUCTION PLAN P a 1/2 A_102 Date. ° E°°°a A-101 2 2 - Project No. ooRoa /4" =1'-0" Drawn By: CDG Regan Residence 480 Dogwood Lane Southold, NY 11971 (631) 765-6826 CHIMNEY EXTEND TO CHIMNEY EXTEND TO 2'-0" PAST ROOF RIDGE 2'-0" PAST ROOF RIDGE NEW CHIMNEY N2 4' 4EW'CHIMNEY l - 24'-4" PATCH AND FLASH NEW ROOF AS REOb o NEW R90F RIDGE NEW ROOF RIDGE 20'-10" NEW ROOF RIDGE 21'-4' � 20'-10" � RELOCATED VENT 12 12 12 r 5 NEW GUTTER 1z 1z --�- _ �, SYSTEM (TYR) Professional Engineer: EXISTING ELECTRIC FROM NEW -_ � NEIN FACIA AND Ron Burk 1'-0' OVER HANG 145 Hickony Road -D" _—- _--� Southold, NY 11971 '91 NEW ROOF RIDGE NEW sDINc As (631) 765-6102 PATCH AND FLASH EXISTING i3'-7 1/2" --------7 REO'O 12 12 ROOF AS REO'D, 12 12� - �12 10. ---- ----- CENT€R-WINDOW-ON-E-XISTINC-RIDGG Arno - ___-- Designer: --- - — —= Christian D. Giordano NEW 2ND FLOOR ^a0 NEW GUTTER — —%/-/ — _�_ NEW 2ND FLOOR 2 South End Avenue (7H) SYSTEM (TVP.) ' -- --- _.—_ _ --- e-g New York, NY 10280 *L —_ � - - -- - -y 1/2. -- -- - 1 -- — __ --------------= nlstla ran c n(<ilcdgio d o. 'om El EE - -- - - - _- - - - -- - - -- B ■� -- --- - - �I --- - - - A-1 A-11 - ! i E _ _ evasions. OFLOOR Revisions: --- No. Date: Description: list FLOOR NEW GRADE - E NEW GRADE - 1'-7 1/2" RED NEW SIDING AS NEW GRADE EXISTI3'-1 i/2"NG GRADE NEW D. T-1" NEW CONCRETE PORCH - 3'-1" WITH BRICK EDGE TRIM FRONT ELEVATION e� RIGHT SIDE ELEVATION 1 1/4 =1 '-p" Key: PAST ROOF RIDGE ® �� -F T 2-00NEY ST ROOF TO — CHIMNEY EXTEND TO O" PAST ROOF RIDGE ------ _� �� NEW CHIMNEY PATCH AND 24'-4' --FLASH NEW NEW ROOF AS RED D _ NEW RGJFRIDGE LOT: 07 21'-4' NEW ROOF RIDGE BLOCK: 09 RELOCATED VENT NEW GUTTERNEW GUTTER NEW CUTTER gr i SYSTEM (TYP.) SYSTEM (TYP,) SYSTEM (TYP) __ - 41 NEW FACIA AND / - - - - Y-0" OVER HANG ' �-- _ ---- __ - Seal: 1 -0 NEW SIDING AS NEW SIDING As NEW ROOF RIDGE EXISTING ROOF PATCH ANDMm! [:T-=A-3 A-3 RESTS REVS. WINOOwCCN{€R€B-BN-R196E 13'-7 1/2" (NO WORK) FLASH EXISTING — ROOF AS REO'U, 12 �10 °F niE�vy - ——4 NEW 2ND FLOOR SHED BEYOND 2ND FLOOR h¢0 g_g EXISTING WOOD DECK (NO WORK) 1 p 1 I , (No WORK) 92_-I --- - 1st FLOOR _ 1st FLOOR _= Drawing Title: NEW GRADE -NEW NEW GRADE EXISTING GRADE EXTERIOR 3 1 2'-10" AC UNIT ELEVATIONS REAR ELEVATION LEFT SIDE ELEVAT16A 3 Scale: Drawing No:T;,_�.,-- Date: 019 01_X)0111 Project No: A-102 Drawn By: one II I --------------------------------- --, FRegan Residence Dogwood Lane SINGLE SIDED ASPHULT ROOF thold, NY 11971 SHINGLE ) 765-6826 i, J'-O" SOLID PLYWD SHEATHING (PROVIDE SNOW & ICE SHIELD) _ ---------------------------------- -- I I 2k8 � i' (2) 14" MICRO ac -o' LAM BEAMS 20 HANGERS S -------------- y I�� 2a8CJ 16" OC. o° � ll Professional Engineer: ` - Ron Burk 145 Hickony Road iarNEW nM e nMs------------------------- —� Southold, NY 11971 - ---- - --------- ___-- �_ i (631) 765-G102 NEW RIDGE �I ` 2X6 ROOF RAF ERS (EXPOSED) I I I i. A-103 M RR Ib" 0C. Designer: NEW ASP GHE - , ' w ROOF sRINb�� Christian D. Giordano o 2 South End Avenue (7H) Z i _ New York, NY 10280 I I II z l I I I I I o SLOPE SLOPE - � II (212) 945-9020 ¢ 1 I� I christiin@cdgiordano.com I o � LINE OF KNEE WALL g I I I I --- ---� -� -- _'----=- `-- =-_---- ------ =- - ---;J, ' BEYOND LOOR �� BIEYOND F ---------------1-- - . -- -----------�.. A-103 � — �-- — _J II I I I I Revisions: NO WORK IN - ---- ----------2xB F.J. o.c. No. Date: Description: I'rb' 3 iH15 AREA �— P I I I I I _________L________ L ________________ --------- ________ __a 16 1/2 m ill OPE re NOTE: - EXISTING 24 FLOOR SEE A-102 FOR NEW ROOF PITCH. - JOIST TO REMAIN c c 20 SPACER 1/2" STEP OVERHANG (2) 2x12 HEADER o ROOF PLAN 1 MTL BRACING 1/4" =1 '-0° AS REQ'D I CONTINUOS WDC — CONTINUOS VENT IN 11 STRINGER Key: SOFFIT WITH INSECT SCREEN CONTINUOS FLASHING _ - ANCHOR AS REQ'D Tul- BUILD4NG SECTION - -- C� — C 2 � = CC — LCC GUTTER i WOOD FACIA TO BE LOT: 07 PAINTED BLOCK: 09 NEW SIDING TO MATCH EXISTING 2,8 RP Ib" CC A DETAIL WITH CONTINUOS VAPOR BARRIER / @ ROOF VENT BEHIND / Q Seal: ---- -- - (2) 14" ICRO----------- ---------- - o M \ � �--- --- ryo�R,� LAM BEAMS CLOSET POLE- AND-7 2x4 HANGERS - -- / i SHELF (TYP.) 24 CJpF NEhi 1/2 PLYWOOD SHEATHING / NEW CLOSET DOOR WITH 1/2 FINISH , � +� (SEE SCHEDULE) MATERIAL LIEU L (2) 2x12 HEADER KNEE WALL IN CLOSET , , y Fix, ... EXISTING 2x6 FLOOR JOISTS TO REMAIN I I 2x8 FLOOR JOISTS LINE OF CEILING BEYOND ANCHOR AS REQ'D C ��� �•� � 2 X 4 KNEE WALL Drawing Title: ------ - -- - -------- - ---- - -- -- - --- --------- - ROOF PLAN �j BUILDING SECTIONS & DETAILS ��II --------------------------- -------------------------------------- --- 2x4 SPACER LAID HORIZONTAL ON HEADER Scale. esNorcn Drawing No: Date: 08 0120o3 SECTION DETAIL @ CLOSET G SECTION DETAIL @ EYEBROWc BUILDING SECTION Project No: 00908 A-103 3 3/4" =1'-0" C NOT TO SCALE 6 /2" =1'-0° Drawn By: CDG Regan Residence VENT THROUGH ROOF 480 Dogwood Lane *NEW OF RIDGE i� Southold, NY 1171 20'-10" - --------_-- -- - (631) 765-6826 _ I I II I I Professional Engineer: HORIZONTAL VENT LINES MIN, 6" Ron Burk ABOVE HIGHEST FIXTURE'S RIM 145 Hickony Road Southold, NY 11971 (631) 765-6102 I Designer: Christian D. Giordano LAV 1 2 South End Avenue (7H) Ii I New York, NY 10280 (212) 945-9020 SUB -- T - christiancdgiordano.com 1 �! 1 ' I Revisions: 11 L No. Date: Description: /-- ,-------------- `-----` I I I IIIA I I ( 4 �I I I ! I I KITCHEN SINK I LAV LAV SHUT OFF W.C. W.C. b WATER HEATER 1 i WATER METER 1 I ';TUBI Key: 1st FLOOR 0'_0" -------- ----------- ----- --- ------- -- - ----- --- CLEAN OUT IN REAR - --- -- - _- --_- _- -_ -- ��/� NEW GRADE LEGEND TO SANITARY SEWERMAIN 2`O" HOT WATER COLD WATER —-—-—-— �- SOIL WASTE � � 10TVENT ------ - PLUMBING RISER DIAGRAM LOT: 07 BLOCK: 09 Seal: WINDOW SCHEDULE Type Description Model # Window Size Head Jamb Sill Mullion Remarks (Rough Opening Width and Height) A-1 Andersen Tilf—Wash Double Hung e TW21C410 * 3'-0 1/8" x 5'-1 1/4" 1/A-105 1/A-105 sim 2/A-105 4/A-105 ASTM E 773 and E 774. A-2 Andersen Arch Windows with Renaissance Grills AFC12 2'—C 5/8" x 2'—C 1/8" 6/A-105 6/A-105 sim 7/A-105 — ASTM E 773 and E 774. _ 19 A-3 Andersen Tilt—Wash Double Hung TW3046 * 3'-2 1/8" x 4'-9 1/4" — 1/A-105 1/A-105 sim 3/A-105 4/A-105 ASTM E 773 and E 774. A-4 Andersen Tilt—Wash Double Hung _ TW20210 2'-2 1/8" x 3'-1 1/4" 1/A-105 1/A-105 sim 3/A-105 4/A-105 ASTM E 773 and E 774. A-5 Andersen Arch Windows with Renaissance Grille AFC11 2'-0 5/8" x 1 '-0 1/8" 6/A-105 6/A-105 sim fi/A-105 — ASTM E 773 and E 774. A-6 — Andersen Tilt—Wash Double Hung TW38210 3'-10 1/8" x 3'-1 1/4" _ _ 1/A-105 1/A-105 sim 7/A-105 4/A-105 ASTM E 773 and E 774. E *These units meet or exceed the following dimensions: C ear Openable area of 5.7 sq. ft., Clear Operable width of 20"' and Clear Operable height of 24". **All Windows based on Andersen Standard windows. Any substitutes to be equal quality and meet local egress codes. DOOR SCHEDULE No. Location Type Model # Width Height Thick. Head Jamb Thr es. Material Hard. Remarks — 101 Entrance Exterior FWH3168AL or EQ. 3'-0" 7'-0" 1 3/4" 1-2/A71.06 8/A-105 Woad 'Typ. ASTM E 773 and E 774.— -- � Drawing Title: 102 Closet Door — 2'-6" 6'-8" 1 3/4" — — Wood ryp. WINDOW & DOOR SCHEDULE 103 Bedroom — 2'-8" 6'-8" 1 3/4" — — Wood Typ. 104 Bathroom - _ 2'-e" 6'-8" 1 3/4" - - Wood Typ. PLUMBING RISER DIAGRAM 105 Linen Closet — 11 6'-8" 1 3/4" — — Wood Typ. — — Scale: asN0'rn:o Drawing No: NOTE: Date: 06-01-2003 ALL WINDOWS & EXTERIOR DOORS IN ACCORDANCE WITH 1609 N.Y. STATE BLDG. CODE & "WITH LARGE MISSILE TEST CERT. (OR WITH STRUCTURAL SHUTTERS & HARDWARE SECTION 1609.1 .4." A-1�4 Project No: oosae Drawn By: CDG IP I Regan Residence 480 Dogwood Lane _ Southold, NY 11971 INSIDE OUTSIDE INSIDE OUTSIDE INSIDE OUTSIDE INSIDE OUTSIDE INSIDE OUTSIDE (631) 765-6826 INSULATING � GLASS INSULATING —i- INSULATING _LI- --INSULATING SS I GLASS GLA GLASS WOOD DOUBLE Professional Engineer: HUNG WINDOW � i Ron Burk WOOD DOUBLE WOOD DOUBLE j ��� - WIN HUNG, WINDow \ j HUNG wlNDow 145 Hickony Road _ " ,��— T - - - - - -- - - - - Southold, NY 11971 i _ �� wooD (631) 765-6102 wooU covE � � � �, wooD � -�` � I SILL AT 1 SILL AT � II FAX CL WOOD 2'6" A F.F. 2'G" A / _�-I1J 6/4 WOOD 'PRIM 2" FEATURE SHINGLE) - INSULATING Designer: WOOD SHIM i— GLASS -- METAL FLASHING !v Christian D. Giordano METAL FLASHING WOOD DOUBLE HUNG 2 South End Avenue (711) New York, NY--L—LINE 212) 945-9020 10280 —LINE Ol+' Chrlstlan@CdglOrdanO.CO WINDOW FRAME HEAD m INSULATING GLASS Revisions: 3 SILL 2ND FL@ DOUBLE HUNG WINDOW 4 TYP HOR MUNTIN @ DOUBLE HUNG WINDOW 5 SILL 2ND FL@ DOUBLE HUNG WINDOW No. Date: Description: HEAD/JAMB @DOUBLE HUNG WINDOW 2 SILL @DOUBLE HUNG WINDOW 3., _V-o„ 3„ _ -0^ 3" =V-0" INSIDE OUTSIDE NSIDE OUTSIDE INSIDE OUTSIDE INSULATING / GLASS �- INSULATING GLASS i WI'fI-I TRUE DIVIDED WOOD SCREEN LITES , \ I DOOR ARCH I --WOOD DOOR L WINDOW �..L DETAIL I9/AI 1.5 Key: IF w00D -BATTY \ �_ SHINGLES J INSULATION (/ - - --LCT FLASHING fLEV bYi ---WOOD HEADER �r� METAL i is WOOD SHIM _ I '� THRESHOLD F WOOD SILL �_ NO _ _ _ --- {900D SPLINE L V100D W/ DRIP - SILL ANDD Ili 2" FE',TUREV -LCC I SHINGLE � � PLASHING LINE OF WOOD � ��' � _ fv WINDOW FRAME SILL - - - HEAD � V _ _ LOT. 07 _ , - \ � � BLOCK: 09 ARCH WINDOW LCC FLASHING - � I INSULATING WOOD ' � ALIGN -PORCH FINISH GLASS SHINGLES—� ^ �` FLOOR _ Seal: HEAD/JAMB @ARCH WINDOW SILL @ ARCH WINDOW SILL @ ENTRANCE DOOR 3" =1'-O" F NE4V � m Zse nio p6. QP Drawing Title: WINDOW & DOOR DETAILS Scale: ASND Mn Drawing No: Date. 0x01-M Project No: 00909 A-105 Drawn By: CDG I, LAILINU CHIMNEY EXTEND TO 2HIDN PAST lid / r✓L 2'-0" PAST ROOF RIDGE L. IY NEW CHIMNEY P G 24,-4,. - y21 V� f rvR( IS`PATCH AND11 SH NEW (j / S1� J MColr ^ i= U ROOF asREO� ✓ ( l�L F Tl n5 fS' G _ r I NEW ROOF RIDGE �' RE ;,.� L. RELOCATED VENT 20'-10" L J ( S 1z lz 12 L IS NEW GUTTER 12 12 SYSTEM -EXISTING ELECTRIC FROM NEW FACIAA N) OK. STREETII ,I 1'-0' OVER HANG G ' I L 0 (TYP) J,NEW ROOF RIDGE NEW SIDING AS PATCH AND FLASH EXISTING 13'-7 1/2" _ REO'O 12 12 ROOF AS REBID 12 12 �12 10� , TER-WINBBW-0N XISIINC-RIB6€-®€L9 — — NEW GUTTER ( �((: SYSTEM (T)"i — i - A2 I F Hiffl,11 Al Al 1 0 FSH'I � LLLIEEEI ISE FLOOR 0. 13 App -rl Z NEW E NEW GRADE GRAD Regan esidence ?I5 >v 480 Dogwood Lane �� �� � A4' 5 � � SoSrvzA C2 L sr Southold, NY 11971 Co /A�' p� o � D cR ' ` 5 i A (681) 765-6826 (� 4 ( "" s b � ( f oNn/ o 11 S S %�•� t l� iA �r P I' s SI ( � flL(� G�I _ ru� ( a A, To 01P e�}4D � ) Ii5 � L (= r25 ,vOryl 4•. I. e n v W Professional E a rA 6 �) � 4L' o�t' Ron Burk S N I 145 Hickony Road �Od sts ��' U Southold NY 11971 P �QQ Iv ( H NEY EXTEND ro A (631) 7656102 ® 51 F'4LT s O' PAST ROOFTRIDGG ^'" �A F 2' O` PAST ROOF RIDGE� �a / t o NEW CHIMNEY (/ il. s `R PATCH AND 24,_4„ N(� L o /, T D FLASH NEW h IIP, b A P,"' >h N 2 Designer: S r-� ROOF As AEG'D. .0 Christian D. Giordano '/ NEW ROOF RIDGE 21'-4" RELOCATED VENT 2 South End Avenue (III) Now Yolk, NY 10280 NEW GUTTER NEW GUTTER 5r / NEW GUTTER SYSTEM (TYP.) (212) 945-9020 SYSTEM (TYP.) O SYSTEM (1YP.) '1 christiari@cdgiordano.com NEW FACIA AND _ 1'-0" OVER HANG \ (TYP) I. ° I ° 0 ISI B _ NEW SIDING AS NEW SIDING AS INBOW-CE-017€R€0-DN�IBG A-3 A-3 EO'0. EO'0 EXISTING ROOF PATCH AND (NO WORK) EXISTING 10 P ■ 12 ROOF AS AEO'D ' � ROOF SHED BEYOND �i L _ NEW 2ND FLOOR - 8'-8EXISTING WOOD DECK --- ❑ ❑ (NO WORK) — Y_4 I/2,. EXISTING WOOD DECK____\\ q � zJ,(NO WOAK)_— _ _ ° 15t FLOOR L _ EXISTING GRADE r� r- 2'-10" - - — -