Loading...
HomeMy WebLinkAbout28589-Z FORM NO. 4 TOWN OF SOUTHOLD BUILDING DEPARTMENT Office of the Building Inspector Town Hall Southold, N.Y. CERTIFICATE OF OCCUPANCY NO: Z-30664 Date: 08/01/05 THIS CERTIFIES that the building ADDITIONS/ALTERATIONS Location of Property: 350 HICKORY RD SOUTHOLD (HOUSE NO. ) (STREET) (HAMLET) County Tax Map No_ 473889 Section 54 Block 6 Lot 11 Subdivision Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated JULY 23, 2002 pursuant to which Building Permit No. 28589-Z dated JULY 23, 2002 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is ADDITIONS & ALTERATIONS TO EXISTING SINGLE FAMILY DWELLING AS APPLIED FOR. The certificate is issued to JOANNE O'BRIEN (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL N/A ELECTRICAL CERTIFICATE NO. 1110991 08/14/03 PLUMBERS CERTIFICATION DATED 01/08/03 or' ed S gnature Rev. 1/81 Form No.6 _y`,•. �t `♦�-�t'r f _TO YN-OF SOIITAOLD - - BUILDING DEPARTMENT TOWN HALL 765-1802 Z 8 ZQn� APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be tilled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: L Final sun ey of property with accurate location of all buildings, property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal(S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2./10 of I% lead. 5. Commercial building, industrial building, multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings (prior to April 9, 1957) non-conforming uses,or buildings and"pre-existing" land uses- 1. Accurate survey of property showing all property lines, streets, building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied, the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$25.00. Additions to dwelling$25.00, Alterations to dwelling$25.00, Swimming pool $25.00, Accessory building$25.00, Additions to accessory building$25.00, Businesses $50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy- $.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential $15.00, Commercial $15.00 Date._ New Construction: Old or Pre-existing Building: i/ (check one) Location of Property: 55 Al c ko: xi y �j 501d/o o /e(/ House No. I (�Stre t Hamlet Owner or Owners of Property: :Y0 a n P1 (/ r't e-n � Suffolk County Tax Map No 1000, Section ] -73 V1 Block Lot Subdivision Filed Map. Lot: Permit No. Date of Permit._ Applicant:_ Health Dept. Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: (check one) Fee Submitted: $ �G � Applicant Signature cv� 30 Gf� y FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N. Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 28589 Z Date JULY 23 , 2002 Permission is hereby granted to: JOANNE O ' BRIEN PO BOX 1533 SOUTHOLD,NY 11971 for ADDITIONS AND ALTERATIONS TO AN EXISTING SINGLE FAMILY DWELLING AS APPLIED FOR at premises located at 350 HICKORY RD SOUTHOLD County Tax Map No. 473889 Section 054 Block 0006 Lot No. 011 pursuant to application dated JULY 23 , 2002 and approved by the Building Inspector to expire on JANUARY 23 , 2004 . Fee $ 150 . 00 thor ze ignature ORIGINAL Rev. 5/8/02 a ��n�n�nrn��l-srn��l-�n�l-srn�s�nns s�rrr�l-r.��nn��n�s�nrnnrsrrs�n��n�I-�rnrs�ns�.nrrrrrs�r�rsr����nr..n�n�r�rs eo 5 BY THIS CERTIFICATE OF COMPLIANCE THE 5 5 NEW YORK BOARD OF FIRE UNDERWRITERS 5 5 BUREAU OF ELECTRICITY C5 Dj 40 FULTON STREET — NEW YORK, NY 10038 5 5 5 S CERTIFIES THAT 5 5 Upon the application of upon premises owned by 5 55 5 5 T& B ELECTRIC JOANNNE O'BRIEN 5 8 DEBBIE LANE 350 HICKORY ROAD 5 5 PATCHOGUE NY, 11772 SOUTHOLD, NY 11971 5 C 5 Located at 350 HICKORY ROAD SOUTHOLD, NY 11971 5 5 Application Number: 1110991 Certificate Number: 1110991 5 Section: Block: Lot: Building Permit: 8DC: ns11 5 Described as a Residential occupancy, wherein the premises electrical system consisting of 5 5 electrical devices and wiring, described below, located in/on the premises at: 5 5 5 rrr5 Basement,First Floor, Outside, �5 A visual inspection of the premises electrical system, limited to electrical devices and wiring to the extent detailed 5 C� herein, was conducted in accordance with the requirements of the applicable code and/or standard 5 5 promulgated by the State of New York, Department of State Code Enforcement and Administration, or other 5 authority having jurisdiction, and found to be in compliance therewith on the Day of 5 14thDay 2003. Name QTS Rate Ratine Circuit: Tyoe 5 5 Alarm and Emergency Equipment 5 Sensor 1 0 Carbon Monoxide 5 5 Sensor 5 0 Smoke 5 L5, Appliances and Accessories 5 5 Exhaust Fan l 0 F.H.P. c_ 5 `wish ivasher 1 u 1.2 KW 5 Range 1 0 11.7 KW 5 5 Air Conditioner 1 0 48.000 BTU 5 5 Wiring and Devices 5 5 Receptacle 9 0 General Purpose 5 5 Switch 7 0 General Purpose 5 SFixture ll 0 Incandescent 5 Dimmers 6 0 5 5 Receptacle 1 0 20 amp Laundry 5 Receptacle 1 0 30 amp Dryer 5 5 Arc Fault Circuit Interrupter 1 0 15 amp 5 5 Receptacle 7 0 GFCI sea/ �+ 5 Service 5 Continued on Next Page 1 of 2 r5 I� This certificate may not be altered in any way and is validated only by the presence of a raised seal at the location indicated. 55 D rJ'rJ'rJLL.Pd'L3 r PLrEJrJr3f�r�r�r nr�rE'r] 701 1 o o �n�nu�srs������nnsss���sr��sss��rr�rsOr, .n rrro 5 BY THIS CERTIFICATE OF COMPLIANCE THE 5 NEW YORK BOARD OF FIRE UNDERWRITERS 5 5 BUREAU OF ELECTRICITY c5 55 40 FULTON STREET — NEW YORK, NY 10038 5 5 CERTIFIES THAT 5 Upon the application of upon premises owned by 5 T & B ELECTRIC JOANNNE O'BRIEN 5 5 8 DEBBIE LANE 350 HICKORY ROAD PATCHOGUE NY, 11772 SOUTHOLD, NY 11971 5 Located at 350 HICKORY ROAD SOUTHOLD, NY 11971 5 Application Number: 1110991 Certificate Number: 1110991 5 c 5 5 Section: Block: Lot: Building Permit: BDC: ns11 r�+ Described as a Residential occupancy, wherein the premises electrical system consisting of 5 5 electrical devices and wiring, described below, located in/on the premises at: 5 Basement, First Floor, Outside. 5 5 5 5 A visual inspection of the premises electrical system, limited to electrical devices and wiring to the extent detailed 5 5 herein, was conducted in accordance with the requirements of the applicable code and/or standard 5 5 promulgated by the State of New York, Department of State Code Enforcement and Administration, or other 5 5 authority having jurisdiction, and found to be in compliance therewith on the Day of 5 5 loth August, 2003. 5 5 5 Name QTY Rate Rating Circuity Type 5 I Phase 3 W Service Rating 200 Amperes [5 5 Service Disconnect: l 200 cb rr5 5 hieters: l 5 5 5 5 5 5 5 5 5 5 Li Sea/ S 5 2 of 2 5 cl This certificate may not be altered in any way and is validated only by the presence of a raised seal at the location indicated. JM 5 �cnrc nrPrJ� rrcn rJ ar�rrur�r�rr�cJ a cn rJ a rJ a cfL3PL o�gpFFO(,�co N Z Town Hall.53095 Main Road Op Fax(631) 765-9502 P.O. Box 1179 y7�1 �aO� Telephone (631) 765-1802 Southold, New York 11971-0959 BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATION Date: Building Permit No. 2' F,s S 9 Owner: j0 '4'f f— Q &&XW (Please print) Plumber: rat A i1 ji� IS ' / F�t ig (Please print) I certify that the solder used in the water supply system contains less than 2/10 of 1°% lead. (Plumbers Signature) Sworn to before me this day of afJiA1 . 2005 Notary Public, County ��D�� JEAN GUIDO Netary Public,State of New York Ab.01ryU6077147-Suffolk Cou* TermEwkn 7•Q•c)6 M-1802 BUILDING DEPT. INSPECTION 1111", FOUNDATION IST [ ] ROUGH PLBG. FOUNDATION 2ND [ ] INSULATION [ ] FRAMING [ ] FINAL [ ] FIREPLACE A CHIMNEY REM KS: �'..- 1 J _ e DATE ��{ 7� INSPECTOR suiLnINc DEPT. INSPECTION- FOUNDATION IST [ ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING [ ] FINAL [ ] FIREPLACE 8 CHIMNEY REMARKS: k-Ltn DATE INSPECTOR � � M-iso2 suiLDiNa car. INSPECTION [ ] FOUNDATION IST [ ] ROUGH PLBG. [ ] F DATION 2ND [ ] INSULATION [ FRAMING [ ] FINAL [ ] FIREPLACE & CHIMNEY REMARKS: l�✓C�.��2 _ (1`�� DATE IN8PECT0 _ V2" 765-1802 BUILDING DEPT. INSPECTION [ ] FOUNDATION IST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [j'J INSULATION [ ] FRAMING [ ] FINAL [ ] FIREPLACE 8 CHIMNEY REMARKS: zi rys . DATE d'/ INSPECTOR <���� M.1802 suauINc DE". INSPECTION [ ] FOUNDATION IST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND INSULATION�<c�, [ ] FRAMING [ ] FINAL [ ] FIREPLACE & CHIMNEY REMARKS: DATE ��'�13 INSPECTOR—l��fY�v` , ass-ieo2 suaoINc oar. INSPECTION [ ] FOUNDATION IST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] 1 CATION [ ] FRAMING [ FlNAL [ ] FIREPLACE & CHIMNEY REMARKS: C22� -c-.a DATE v'u p'3 INSPECTOR BUILDING PERMIT EXAMINER CHECK LIST DATE REVIEWED: 77-//,�,5/02 APPLICANT: u, _( ft; z� DATE SUBMITTED: 02 SCTM#DISTRICT: 1,000, SECTION: , BLOCK: , LOT: STREET ADDRESS y . CITYcx SUBDIVISION: NA xq4. PROJECT DESCRlPTION: A ; ESTIMATED PROJECT COST: ARCHITECT4ESE R:( )MjAa�) FAST TRACK? A0 SINGLE & SEPARATE CERTIFICATION-REQUIRED? � NOTES: LOTS 40,000SF-100-24.Lot recognition.(CREATED before June 30,1983),UNDERSIZED LOTS FROM JAN.1997 100-25.Merger.(A nonconforming at any time after 7/1/, ZONING DISTRIC CONFORMING? REQ. LOT SIZE'//J,DOD ACT. LOT SIZE:,Z Z REQ. LOT COV ACT. LOT COV. d` REQ. FRONT S PROP. FRONT /OQ SIDE /D ACT. SIDE REQ. REAR �=� PROP. REAR _ REQ. HEIGHT PROP. REICHT WATER FRONT? DESCRIPTION: PANEL #: jA__ FLOOD ZONE: , APPROVALS REQUIRED SUFFOLK COUNTY HEALTH DEPT: YES orep, (BED #): DTE: PERMIT PERMIT#:R10- TOWN SEPTIC RECEIPT: Y ore AkpNL l r'rt- phi' NEW YORK STATE DEC: PRE-DEC 9/1/75 YES orev SOUTHOLD TOWN TRUSTEES: YES o TOWN ZONING BOARD APPROVAL: YES or TOWN PLAN. BOARD APPROVAL: YES o TOWN HISTORICAL PRE (SPLIA): S or NYS ENERG VYE OR NO EGRESS (18 4 sq total) ..•�'VE (SQ. FT. x 4%) LIGHT (SQ. FT. x 8%) BUILDING PERMITS OPEN/EXPIRED: BP -Z/C/0 Z- , HAVE PRE CO'S : Y OR N BP -Z/C/o Z- , NOTES: i-rrA_A^, FEE STRUCTURE: FOUNDATION: SF FIRST FLOOR: `fes g' SF SECOND FLOOR: f,'Z SF OTHER: SF INIT OTHER TOTAL TOTAL: 7&I SOO SF FEE FEE A 1. ( SF)- SF)= SFX$ =$ +$ +$ _ $ 2. ( SF)-( SF)= SFX$ =$ +$ +$ = $ NOTE: APPLY 26 WATERPROOFING TO ALL EXTERIOR SURFACES OF CONC P BLOCK BELOW GRADE (2) 2" X 6" CCA TREATED —(l)CA TREATED SIX 4'f SILL PLATE W/ METAL TERMITE SHIELD TO PLATE W/ METAL CODETERMITE SHIELD TO CODE 2" X 10" FLR JSTS 1/2" DIA X 12" LONG ANCHOR BOLT (TYP) 0 8"H X 12" W 8"H X 6" W CONC iv CONC BLOCK 1--0., o ? BLOCK-TIE TO FLOOR JSTS W/ MASONRY TIES OF NE,y y�PtE YOF 2" THICK CONCRETE RAT SLAB SPR° W. ZA,hMIN °oma * G C QFC NO. 54940 (3' .� �OFES 10 PROPOSED EXTENSION FOR O'BRIEN RESIDENCE 350 HICKORY ROAD, SOUTHOLD, NY 11971 REVISED FOUNDATION DETAIL DRAWN BY: RWC DATE: NOV. 2002 SCALE: 3/8"=1 '-0" Richard. W. Cuming, P.E. Bellport, New York 11713 (631) 286-3617 DWG 1 0 F 1 Richard W. Cuming, P. E. 28 Bellhaven Road Bellport, New York 11713 (631) 286-3617 July 12, 2002 Town of Southold Building Department Main Road Southold, New York 11971 Re: Proposed Extension to O'Brien Residence 350 Hickory Road, Southold, New York 11971 To Whom It May Concern: The attached construction plans and application for a building permit request approval for the construction of an extension to and renovations of an existing two (2) bedroom residence which will result in the addition of one (1) bedroom to the existing structure. I hereby certify that the existing sanitary disposal system for this residence should be adequate to treat additional wastewater which might potentially be generated as a result of the additional bedroom. If you have any questions, please do not hesitate to call. Sincerely, 5 L LE, OF NEIV J-OO. Richard W. Cuming, E. ! R0 W. r C? � /� 'FESSiOti'�F Permit Number MECcheck Compliance Report Checked By/Date New fork State Energy Conservation Construction Code MECcheck Software Version 3.3 Release lc Data filename: C:\Program Files\Check\NffiCcheck\J. O'Brien Energy Calcs.cck TITLE: Proposed Extension @ O'Brien Residence COUNTY: Suffolk STATE: New York HDD: 5750 CONSTRUCTION TYPE: Detached 1 or 2 Family HEATING TYPE Non-Electric DATE: 07/18/02 DATE OF PLANS: June 2002 PROJECT INFORMATION: Joanne O'Brien Residence 350 Hickory Road Southold, NY 11971 COMPANY INFORMATION: Richard W. Curring, P. E. 28 Bellhaven Road Bellport, NY 11713 COMPLIANCE Passes Maximum UA= 101 Your Home= 101 0.0%Better Than Code Gross Glazing Area or Cavity Cont. or Door Perimeter R-V a R-ValueU Factor ILA Ceiling 1: Cathedral Ceiling(no attic) 362 19.0 0.0 18 Skylight L Wood Frame, Double Pane with Low-E 18 0.340 6 Wall 1: Wood Frame, 16" o.c. 576 13.0 3.0 35 Window I Wood Frame, Double Pane 21 0.340 7 Door I: Glass 39 0.320 12 Door 2: Solid 1111, 0 340 6 Floor I: All-Wood JoisttTruss, Over Unconditioned Space 362 190 0.0 17 COMPLIANCE STATEMENT. The proposed building represented in this document is consistent with the building plansspecifications, and other calculations submitted with this permit application. The proposed systems have been designed to meet the New York State Energy Conservation Construction Code requirements When a Registered Design Professional has stamped and signed this page, they are attestine that to the best of his/her knowledge, belief, and professional judgment, such plans or specifications are in compliance with this Code. BuilderlDesigner ��.C�.�..�,1-__ _ ` Date--7/—ul—oZ___.. OF NEW yo 5 P�D W. 0 R� r i � cf W 2 54 940 N v SSIWAP MECcheck Inspection Checklist New Fork State Energy Conservation Construction Code MECcheck Software Version 3.3 Release lc DATE 07 1S 02 TITLE. Proposed Extension @ O'Brien Residence Bldg. Dept Use I Ceilings: [ ] I Ceiling 1: Cathedral Ceiling(no attic), R-19.0 cavity insulation Comments. I Above-Grade Waits: [ ] 1. Wall L Wood Frame, 16" o.c., R-13.0 cavity+R-3.0 continuous insulation Comments I Windows: [ ] 1. Window 1: Wood Frame, Double Pane, U-factor: 0340 For windows without labeled U-factors, describe features: #Panes_Frame Type Thermal Break? [ ] Yes[ ]No Comments I Skylights: [ ] 1. Skylight ]: Wood Frame, Double Pane with Low-E, U-factor: 0.340 For skylights without labeled U-factors, describe features #Panes_Frame Type Thermal Break? [ ] Yes[ ] No Comments: I Doors: [ j I Door 1: Glass, U-factor. 0 320 #Panes_Frame Type Thermal Break? [ ] Yes[ ]No Comments: [ j 2. Door 2Solid, U-factor: 0.340 Comments: I Floors: [ ] 1. Floor l: All-Wood Joist/Truss, Over Unconditioned Space, R-19.0 cavity insulation Comments: Air Leakage: [ ] Joints,penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed [ ] Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air-tight assembly with a 0.5" clearance from combustible materials If non-IC rated, the fixture must be installed with a 3" clearance from in;uLltion I Vapor Retarder: [ ] i Required on the warm-in-"niter side of all non-vented framed ceilings, walls, and floors. I i Materials Identification: [ ] Materials and equipment must be installed in accordance with the manufacturer's installation instructions [ ] Materials and equipment must be identified so that compliance can be determined. [ ] Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided [ ] Insulation R-values and glazing U-factors must be clearly marked on the building plans or specifications. I Duct Insulation: [ ] Supplv ducts in unconditioned attics or outside the building must be insulated to R-8 [ ] I Return ducts in unconditioned attics or outside the building must be insulated to R-4. [ ] I Supply ducts in unconditioned spaces must be insulated to R-8. [ ] Return ducts in unconditioned spaces(except basements)must be insulated to R-2. I Insulation is not required on return ducts in basements. I Duct Construction: [ ] I All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives), mastic-plus-embedded-fabric, or tapes. Duct tape is not permitted. Exception: Continuously welded and locking-type longitudinal joints and seams on ducts I operating at less than 2 in. w.g. (500 Pa). [ ] I Ducts shall be supported every 10 feet or in accordance with the manufacturers instructions [ ] I Cooling ducts with exterior insulation must be covered with a vapor retarder. ( ] I Air filters are required in the return air system. [ ) I The HVAC system must provide a means for balancing air and water systems. I Temperature Controls: [ ) I Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space temperature set point of the largest zone. I I Electric Systems: [ ] I Separate electric meters are required for each dwelling unit. I Fireplaces: [ ] I Fireplaces must be installed with tight fitting non-combustible fireplace doors. [ ) Fireplaces must be provided with a source of combustion air, as required by the Fireplace construction provisions of the Building Cotte of New York Stale,the Residential Code of New York State or the New York Citi.Building Code, as applicable. I Service Water Heating: [ ] I Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. [ ] I Insulate circulating hot water pipes to the levels in Table 1. I Circulating Hot Water Systems: [ ] I Insulate circulating hot water pipes to the levels in Table 1. I Swimming Pools: [ ) I All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. I Heating and Cooling Piping Insulation: [ ] FIVAC piping conveying fluids above 105 OF or chilled fluids below 55 OF must be insulated to the lesels ut Table ' Table l: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non-Circulative Runouts Circulating Mains and Runouts Temperature LF) Up to I" UP to 1.25" 15" to 2 0" Over 2" 170-180 01 1.0 L5 20 14o-160 05 0 S l u 1.5 100-130 0.5 0 5 OS 1.0 Table 2: minimum Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types R_an�F.e( F) 2" Runouts V and Less 1 25" to 2" 2_5"to 4"_ Heating Systems Low Pressure/Temperature 201-250 LO 1.5 1.5 20 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate(for feed water) Any 1.0 1 0 1 5 20 Cooling Systems Chilled Water, Refrigerant, 40-55 05 0 -' 075 1.0 and Brine Below 40 1 0 LO 1.5 1.5 NOTES TO FIELD(Building Department Use Only) n , I. A � n FIELD INSPECTION REPORT DATE COIVT3 ` Y -- w FOUNDATION DIST 71 ----------------- - - -- _ j II: FOUNDATION k2NDi ✓y ry i ROUGH FRAMING d- PLUNIBING y I ii�s&�a3 S INSULaTION PER N.�'. , STATE ENERGY COLE i /L Gcrua� , i FINAL ADDITIONAL CONMENfS O ZE Z m —f—f f�ff f —1 � I I z �" yl zl i = li TI � I y � J TOWN OF SOUI'HOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying TOWN IIALL Board of Health SOUTHOLD, NY 11971 3 sets of Building Plans s/ TEL: 765-1802 Survey PERMIT NO Check .ft 115 y Septic Form N.Y.S.D.E.C. 2 Trustees Examined lt5 20 L Contact: Approved z ,20_ - Mail to: Disapproved a c Phone: - uild ' Inspector L_ 1 APPLICATION FOR BUILDING PERMIT L '-- -- - - Date Jt/L-y 1Z— , 200Z- INSTRUCTIONS pOZINSTRUCTIONS a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 3 sets of plans, accurate plot plan to scale.Fee according to schedule. b- Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas,and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what-so-ever until a Certificate of Occupanc} is issued by the Building Inspector. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code,housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. (Signature of applicant a ame,if a cotporauon) S5 BEu.NA-JE.i Ro (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician,plumber or builder ��J�e�JFf51L. Name of owner of premises J0A0A O S2t£r,) (as on the tax roll or latest deed) If applicant s a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. Plumbers License No. Electricians License No. Other Trade's License No. 1. Location of land on which proposed work will be done: 3550 WtcK0V_q eo,pQ SoU tNa41� House Number Street Hamlet County Tax Map No. 1000 Section OSS- Block (w Lot L Subdivision Filed Map No. Lot (Name) 2. State existing use and occupancy of premises and intended use and occupancy of proposed conshnction: a. Existing use and occupancy. S1rY Lt ter►itr �t ��Sinf�t=1+!¢. b. Intended use andoccapancy S�aJGtf Fp►1/t4 i2€Stl ,tl)+1e, 3. Nature of work(check which applicable):New Building Addition__L/_Alteration 1/ Repair Removal Demolition Other Work (Description) 4. Estimated Cost # J� 000 Fee (to be paid on filing this application) 5. If dwelling, number of dwelling ups Number of dwelling units on each floor If garage, number of cars A704 )) 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. i11 A Dimensions of existing structures, if any: Front �D �� - Rear Sa-G 4`f-1 Depth e4 i4„ Height /8` Number of Stories _✓Arts Dimensions. of s me structure with alterations or additions: Front 63� �l Rear Depth 36-C" *- M 1C Height J8 t y Number of Stories 8. Dimensions of entire new construction: Front /.3 Rear /3-4* Depth 8" Height /8 ` x" Number of Stories_ / 9. Size of lot: Front _1001 Rear /00,06 ' Depth /ZS,Z7�►!3!,8/ ✓R�r E S) 10. Date of Purchase 167 gZ Name of Former Owner OL-0 FikQ 11. Zone or use district in which premises are situated 12-40 12. Does proposed construction violate any zoning law, ordinance or regulation: /JO 13. Will lot be re-graded-_-A/0 Will excess fill be removed from premises: a NO 14. Names of Owner of premisesJOVIA 0'aX+C_Address3�PW0t11_ 0 Soo�h ne No. G51-'7/.5- 1456 Name of Architect RhR-0 ieHid g A E. Address?68Fi A4u1J'90 k�b one No 631-Z86 3617 Name of Contractor Address Phone No. 15. Is this property within 100 feet of a tidal wetland? *YES NO i// • IF YES, SOUTHOLD TOWN TRUSTEES PERMITS IALAY BE REQUIRED 16. Pro;ide sun-ey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. STATE OF NEW PORK) SS: COUNTY OF ) Li being duly sworn, deposes and says that(z)he is the applicant (Name of mdi-,idual signing contract)above named, (9)He is the f T (Contractor, Agent, Corporate Officer,etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. Sworn to before me this L day of 20 il_ AU No Public Signature of Appli -�70Z 'Lo 6eW sandx3 uwss1wwo3 , f4unoo nesseN u1 pagllenp L9Z9964•ON voAMaN to%Ens'onand AmvioN N018NM39 3Ntl1U t: MAP OF_.�PQ0 P E4TY tLi - - - - SU2VEYED FOr2. r : 3 JOANNE O' E321E i,\1 BERGAN I AT m � SOUTHOLD TOWN OF SQUTi-{OLD.KY, g 4i o ci . 9 39' VY 8 L „ ^ 3 W N p LL Iid LLQ ; o � � N b SIC ALE = 40'• !" 2Z / G'IRON PIPE ;4 �g' 0" p„WUNUMENT I 7 TITLE NO.- 56&0258 '50' IGIRINCIC / 0"UMORILM ALTIKAIION OR AMIRt IO THIS SURVEY IS A VIOLATION Of PCTIOM 7209 OF THE NEW TOY(STAn WDCATION LAW. GUARANTEED Tl_, JOANNE O'B21E'N SECUrCTY TITLE. — CAPIES OF THIS SURVEY MN NOT REARUq AND GUARANTY '-.�. AND 7i THE 0',i THC)L-, -;-� V�5 M LAND SURVEYOR'S INKED , SEAL OR -- �' -- - LVAOSSFD SEAL SHALL NOT M CONSIDERED BAN K — _A5 SUr2 V_E'Y_E O — h:i,'✓,t jCC,,i3� .. r T GU IEA VALID TRUE COPY, i'J I -VA�� / IJI � L EPC M ONLY T IIIS INDICATED HEREON SHALL RUN i`.•.J •C` :` Y ' SUFI- CO,TAX MAP DATA IIPREPARED,EAND SON HIS SEHON FOR OLF TOTHE [YFI _ TITLE COMPANY, GOVE[.NMENTAL AGENCY AND - /� LENDING RESTITUTION LISTED HEREON, AND TO ME ASSIGNEES Of THE LENDMG INSTI � -.S�s `�— ) 5•LJ V , / / TUITION.'GUARANTEES ARE NOT TRANS"— yo ADDITIONAL R RAIWE•,.^oAoomaEALR m,uv,w ^R TI,L.. LIC. AND SURVEYORS - GREEfNPORT NY. SOUND VIEW AVE. A 2 134• r� I 94r s-r• 1'4r Uj 4 4 REMOVE EXISTING r X e'ROOF RAFTERS,ROOF SHEATHING o �t� B'X te•FDTN VENT SHOWN ROOFING EXISTINEXTEG TS INSTALL TEMPORARY SUPPORT a4' (TYPICAL FOR4) KffCHEN AREA ONLY WALL A8 SHOWN PRIOR TO G ROOF N RAFTERS ANREMOVAL OFD CEI NO JOISTS r RAT SLAB ® IlJ N Oro 49'40'E 1�•� b / EXISTING ATTIC JJrr REMOVE EXISTING r X E•CEILING ' 7Yf" JOISTS,SHEETROCKAND INSULATION $ )y (2)1 a•x l4"GP-tAM / E rr (� ITGOrEXTENTSHEN AREA ABOVE EXISTING dpi � ti � � EMOTING Eurnme CONSTRUCT POCKETS KITCHEN BEDROOM HOLD 4• (2)IN FDTN WALLS TO G� PROPOSED 13'--C X 2r-W RECEIVE NEW GIRDER, 'Y i APPROX4•XMX12' f� I ADDITION DEEP-GROUTISHIM y ' GIRDER AS REQUIRED , EXISTING EXISTING V�VLSPACE EXISTING CONCRETE BLOCK FDTN rt fi CONIC V ; m ON r X Ir PTO(CONTRACTOR TO EDG BOCK FDTN _ VERIFY IN FIELD) b �.' EXISTING b N X ap i' BASEMENT EIISTWCON° 4 tv N BLOCK WALL z q7m 84ro 4Ir4D•W 131.81' rJr s-0• sem• r oT PLOT PLAN 1T- REMOVALS SECTION SCALE: 1" =20' A SCALE: 1/4"= 114r . 2 EXISTING BRICK CHIMNEY ON CONCRETE EXISTING DECK FOUNDATION-CONTRACTOR TO VERIFY DEPTH OF FDTN AND PROTECT AS REWIRED GENERAL NOTES AND REMOVE EXISTING WINDOW AND LTJ/ FOUNDATION PLAN IN DO F &WINDOW INDICATED IN DooR a WINDOW REMOVE SECION OF EXISTING DECK SPECIFICATIONS 9CMEDULE FRAMEIN OPENING OF NECESSARY PROJECTTOTOC ORIGINAL CT CONDITION AND FINISH AS SHOWN ON FIRST FOUNDATION-RESTORE DECK AT END SCALE: 1/4• = 1'-0' FLOOR PLAN OF PROJECT TO ORIGINAL CONDITION UNDER,01TERS CERTIFICATE REQUIRED REMOVE EXISTING*LINING DOOR AND FRAME-REINSTALL PL UAIRER CFRTOF/CAT/ON AP R VEDAS NOTED 1. ALL WORK SHALL CONFORM TO NEW YORK STATE AND LOCAL BUILDING CODES. AS INDICATED IN DOOR a ON LEAD CONTENT BEFORE DATE' P.J WINDOW SCHEDULE CERTIFICATE OF OCCUPANCY FEE: � BY' 2. ALL WORK SHALL CONFORM TO NEW YORK STATE ENERGY CONSERVATION CODE. 3. ALL ELECTRICAL WORK SHALL BE FIRE UNDERWRITERS INSPECTED AND APPROVED. SOLDER USED /N I l/ATER NOTIFY UI AM T DEPARTMENT AT 4. CARRYALL FOUNDATIONS DOWN TO UNDISTURBED EARTH HAVING A MINIMUM BEARING SUPPLY 2110FOUI CANNOT 765.1802 9 AM To 4 PM FOR THE CAPACITY OF 2 TONS PER SQUARE FOOT. NOTIFY ENGINEER IMMEDIATELY IF UNSUITABLE SOILS OT FOLLOWING INSPECTIONS: F-xCEED 2/7Q ULA% LEAD. t. FOUNDATION - TWO REQUIRED REMOVE EXISTING EXTERIOR FOR POURED CONCRETE EXIST. WALL ro uMrrs SHOWN-FRAME PLUMBING 2. ROUGH - FRAMING & PLUMBING 5. CONCRETE FOR FOOTINGS, FOUNDATIONS AND SLABS-ON-GRADE GRADE 3HAlL HAVE BA -0IN MUSTTH �+ COMPRESSIVE STRENGTH OF 3,000 PSI AT 28 DAYS AND SHALL CONFORM TO THE LATEST NEW OPENING LA SHOWN ON ALL WATER LINE NEED 3. INSULATION FIRST FLOOR PLAN aNG Efl LINES NEED A FINAL - CONSTRUCTION MUST REQUIREMENTS OF ACI 318. TESTING BEFORE COVERING BE COMPLETE FOR C.O. 8. CONCRETE BLOCK FOR FOUNDATIONS SHALL BE HOLLOW, LOAD-BEARING, CONFORMING TO THE ALL CONSTRUCTION SHALL MEET EXIST BEDROOM EXIST BEIXi00M REMOVE EXISTING WINDOW-PRAME THE E REQUIREMENTS OF THE N.Y. LATEST REQUIREMENTS OF ASTM C-9O. IN OPENING AND FINISH AS SHOWN STATE CONSTRUCTION & ENERGY 7. FRAMING LUMBER SHALL BE DOUGLAS FIR, NO. 2 GRADE OR BETTER,WITH A MINIMUM BASE ON FIRST FLOOR PLAN If copper tubing is used CODES. NOT RESPONSIBLE FOR VALUE EXTREME FIBER STRESS IN BENDING OF 850 PSI. WOOD MEMBERS IN CONTACT WITH for water distributing DESIGN OR CONSTRUCTION ERRORS CONCRETE OR MASONRY, USED FOR EXTERIOR DECKS OR PLATFORMS, OR WHERE INDICATED ON REMOVE EXISTINGOPENINGS WINDOWSELECTIC sySityp piping shall be THE PLANS, SHALL BE SOUTHERN YELLOW PINE, CCA TREATED TO A RETENTION OF 0.40. FRAMING FINISH AS IN OW NIN FIRST EXISTING PANEL TO RWrt of types I< or L only FINISH AS BROWN ON FIRST BREAKER PANEL TO REMAIN- EXIST PROVIDE S MO�E-DETECTING SHALL BE N0. 2 GRADE OR BETTER AND DECKING SHALL BE N0. 1 GRADE OR BETTER WHERE FLOOR PLAN EXIST HALLWAY CONTRACTORTOPROTF% EXIST DEN UNDERWRITERS CERTIFICATE ALARM DEVICES 21.1 SHOWN ON THE PLANS, EXTERIOR POSTS, RAILINGS AND/OR DECKING SHALL BE CONSTRUCTED WITH REQUIRED AS TO PART. CO WESTERN RED CEDAR, NO. 1 GRADE. N.Y.S BUILDING CODE. S. HEADERS SHALL BE SIZED AS SHOWN ON THE PLANS AND/OR IN THE DOOR AND WINDOW PROVIDE SHOO C PRE AND/OR SCHEDULE. WHERE NOTED, HEADERS, RIDGE BEAMS, GIRDERS, VALLEY AND/OR HIP RAFTERS SHALL THERMAL SNOOK PREVENTING BE CONSTRUCTED WITH G-P LAM LVL (LAMINATED VENEER LUMBER)BEAMS AS MANUFACTURED BY DEVICES TE TO PART. CODE- PROVIDE COPENINGSSOAP FOR GEORGIA-PACIFIC. ALL MANUFACTURER'S RECOMMENDED INSTALLATION PROCEDURES SHALL BE N.Y. STATE BUILDING CODE. EMERGENCY ESCAPE AS EXIST KITCHEN REQUIRED BY PART. 714 OF COMPLIED WITH. 9. DOUBLE FLOOR JOISTS SHALL BE INSTALLED UNDER ALL INTERIOR PARTITION WALLS RUNNING N.Y. STATE BUILDING CODE. PARALLEL TO THE JOISTS. SKYLIGHT OPENING IN ROOF SHALL BE FRAMED WITH DOUBLE ROOF EXIST STORAGE EXIST DINING ROOM RAFTERS ON BOTH SIDES AND DOUBLE HEADERS TOP AND BOTTOM. OR 10. THE CONTRACTOR IS RESPONSIBLE TO PROTECT THE EXISTING STRUCTURE AND ITS CONTENTS OCCUPANCYS UNLAFU AT ALL TIMES FROM EXPOSURE TO THE WEATHER.WHERE EXISTING WALLS OR OTHER STRUCTURAL USE )S CERTIFICATE L ELEMENTS ARE SHOWN TO BE REMOVED, TEMPORARY SUPPORTS AS REQUIRED SHALL BE REMOVE EXISTING WINDOWS WITHOUT CERTIFICATE INSTALLED PRIOR TO THE REMOVALS. DISINGCONICDECK (3KRAMENEW OPENINGS AS OF OCCUPANCY Jr/' 11. THE CONTRACTOR AND ALL OF HIS SUBCONTRACTORS SHALL BE LICENSED AND INSURED TO REWIRED FOR NEW DOOR AND "`E °F "EIv ` PERFORM THE WORK OF THIS PROJECT AS REQUIRED BY THE LOCAL GOVERNING JURISDICTION. SCHEDULE)(SEE DOOR a WINDOW ° 12. THE CONTRACTOR SHALL VISIT THE PROJECT SITE PRIOR TO THE START OF CONSTRUCTION IN SOHEDULE) * 5 �PR� W REMOVE EXISTING WINDOWS ` 2 * PROPOSED EXTENSION Q O'BREN RESIDENCE ORDER TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS. HE SHALL REPORT ANY NEW OPENING FOR NEW WINDOWS DooR FRAME IN OPEN NI °AND c " DESCREPANCIES BETWEEN THE PLANS AND HIS FINDINGS TO THE ENGINEER IN WRITING PRIOR TO AND FlNLO RPLAINDERA88HOVNON FINSH AS SHOWN ON FIRST i T ' �W 350 HICKORY ROAD, SOUTHOLD, NY 11971 THE START OF CONSTRUCTION. FlRSrFoRAN 13. THE CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR ALL MEANS AND METHODS OF FL °p N�' 5494 �� PLOT PLAN, REMOVALS PLAN & SECTION pFessioaP FOUNDATION PLAN, GENERAL NOTES Er SPECIFICATIONS CONSTRUCTION AND SHALL ADHERE TO ALL APPLICABLE SAFETY STANDARDS AND REGULATIONS. ° FIRST FLOOR REMOVALS PLAN DRAWN BY: RWC DATE: JUNE 2002 SCALE: AS SHOWN 3CALE: 1/4" = ,'-0 Richard. W. CuminC�T P.E. Bellport, New York 11713 (831) las-3817 DWG 1 OF 3 ADOOR & WINDOW SCHEDULE 2 ��. MARK NO. OF DESCRIPTION HEADER NUMBER UNITS SIZE W1-1 D1-1 1 REINSTALL EXISTING W-W x 8'-8" SLIDING PATIO DOOR AND FRAME AT LOCATION (2)2"X W 1rd' SHOWN. CONTRACTOR TO VERIFY ROUGH OPENING REQUIRED. NEW DINING AREA D1.2 1 2'-8•X8'-8' PREHUNG EXTERIOR STEEL DOOR, THERMA-TRU MODEL NO. 282 OR (2)2"X 8" a EQUAL,WITH EXTERIOR LOCKSET AND DEADBOLT KEYED ALIKE WITH EACH EXISTING DECK b OTHER AND WITH DOOR D7-4. D1-3 1 ONE(1) PAIR OF WOOD BIFOLD DOORS, EACH 3'-0•X 8'-8•,WITH SIFOLD DOOR (2)2'X 6' HARDWARE. DOORS TO BE 1/3 SOLID PANEL AND 213 LOUVERED. I: 1- s3 VLXbHr E DI-41 W-W X 8'-8" PREHUNG EXTERIOR STEEL DOOR, THERMA-TRU MODEL NO. 530, (2)2"X 8' ss r WITH MODEL NO. 530SL 14"WIDE SIDELIGHT OR EQUAL,WITH EXTERIOR LOCKSET AND DEADBOLT KEYED ALIKE WITH EACH OTHER AND WITH DOOR D1-2. D1-5 1 Z-W X V4r PREHUNG HOLLOW LUAN FLUSH DOOR WITH PASSAGE LOCKSET. (2)2"X W B 2 NEW KITCHEN a D1$ 1 2'4'X B'$' PREHUNG HOLLOW LOAN FLUSH DOOR WITH PRIVACY LOCKSET. (2)2"X 8' (2)r aTovE slivuoHr D1-7 1 ONE (1) PAIR 2'-0"X 8'-8" HOLLOW LUAN FLUSH DOORS WITH SLIDING DOOR (2)2"X 8" ABOVE HARDWARE AND PULLS. T41! 9 W 1 b r STEP a D1-8 1 2'-0"X 8'-0" PREHUNG HOLLOW LUAN FLUSH DOOR WITH BATHROOM LOCKSET- (2)2"X 8" EXIST BATH H: SINK W 1 2 132.1 1 2'4"X 8'-0" PREHUNG HOLLOW LUAN FLUSH DOOR WITH PASSAGE LOCKSET. r-0• (2)2"X 8" Ir 1 DW a W1-1 1 TWO(2)ANDERSEN NARROLINE DOUBLE HUNG WINDOWS, MODEL NO. 2842, (2)2'X 8' EXIS.BEDROOM EXIST BEDROOM ® FACTORY JOINED WITH ANDERSEN NARROW MULLION KIT, IN WHITE, WITH ) PERMA-CLEAN INSECT SCREENS IN WHITE. LAUNDRY b N REM �� " W1-2 1 ANDERSEN NARROLINE DOUBLE HUNG WINDOW, MODEL NO. 20210, IN WHITE, (2)2"X 8' Ile EXISTING ELECTICCIRCUIT r a „F f `� WITH PERMA-CLEAN INSECT SCREEN IN WHITE. BREAKER T (2)2"X 8" �� ,30' L W13 1 REINSTALL EXISTING TWO (2)WINDOWS AND MULLION AT LOCATION SHOWN. EXIST HALLWAY CONTRACTOR TO ROTECT- EXISTDEN CONTRACTOR TO VERIFY ROUGH OPENING REQUIRED. r a.1• ,a 9• b CLOSET ( W1.4 1 ANDERSEN NARROLINE DOUBLE HUNG 30 DEGREE ANGLE BAY WINDOW, MODEL (2)2•X 8" A NO. 30-3442-18, PROVIDED WITH PINE HEAD &SEAT BOARDS AND CABLE JACUZZI TUB �' ra INBTALLNEwSTRS(OPEN) 2 SUPPORT SYSTEM. WINDOWS IN WHITE WITH PERMA-CLEAN INSECT SCREENS IN 9' fir HI H RISERS(OPEN)®APPROX 77nr HIGH(CONTRACTOR ToVERIFY 1N FIL1D). WHITE. NEW MASTER BEDROOM NEW HALLWAY OWNER TO SELECT STYLE.HANDRAIL 8 ALIGN W/LANDING BALLUSTERS TO CODE, NEW BATH f; NG ABOVE W1S 1 TWO (2)ANDERSEN NARROLINE DOUBLE HUNG WINDOWS, MODEL N0. 2442, EXIST HEADER NEW ENTRY FOYER @ r;. FACTORY JOINED WITH ANDERSEN NARROW MULLION KIT, IN WHITE WITH LTKY PERMA-CLEAN INSECT SCREEN IN WHITE. S1-2 —`�`.� � 1 W2-1 1 ANDERSEN AWNING WINDOW, MODEL NO. AW51, IN WHITE, WITH INSECT SCREEN (2)2"X 8' ® FW-1-74 IN WHITE. SHOWER EXISTING CONC DECK 0 31-1 2 INSULADOME VENTED SKYLIGHT, 30•X 45"WITH INSULATED SAFETY GLASS, WA PITCHED ROOF MODEL. W1� fl B 2 S1-2 1 INSULADOME VENTED SKYLIGHT, 22•X 30"WITH INSULATED SAFETY GLASS, WA PITCHED ROOF MODEL. FIRST FLOOR PLAN TYPIDABFELTPANBTRIxT,ON: NOiEC PROPOSED +ROOF SHINGLES TO MATCH EXISTING +16 LB PELT PAPF3i 1. CONTRACTOR SHALL VERIFY ALL ROUGH OPENING REQUIREMENTS WITH EACH RESPECTIVE MANUFACTURER +1/r cox PLvwaoD BHPATHINo 2. ALL DOORS, WINDOWS AND SKYLIGHTS SHALL CONFORM TO THE REQUIREMENTS OF THE NEW YORK STATE ENERGY +rxe'ROOF RAFTERS Q IW OC CONSERVATION CONSTRUCTION CODE, INCLUDING AIR INFILTRATION RATES OF 0.37 CFM/LIN FT MAX FOR WINDOWS AND +R-19 FIBERGLASS BATT INSULATION W/VAPOR BARFUER-INSTALL 0.50 CFM/LIN FT MAX FOR DOORS. 'RAFT-R•MATE'VENT BOARDS 3.ALL DOORS AND WINDOWS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S SPECIFIC +,rr SHEETROCK-TAPE,SPACK.E&PAINT INSTRUCTIONS AND RECOMMENDATIONS, INCLUDING THE USE OF APPROPRIATE SEALANTS, FLASHINGS,ETC. SPLICE NEW rxe"RR'BONTO EXIST g TYPICAL ROOF CONSTRUCTION: r X e'RR'S(MIN SPLICE 34)-)EXTEND 2 +ROOF SHINGLE8 TO MATCH EXI8TMKi 72 TO NEW RIDGE BEAM.CONNECT W/ +15 LB FELT PAPER 4 12A NAILS e'OC,DOUBLE ROW +,YC COX PLYWOOD SHEATHING RIDGE BEAM-EAD R4 X,4 TYPICAL EXT•WALL CONSTRUCTION: +r X e•ROOF RAFTERS 7e•OC OP-LAM LVL HEADER RIDGE HT TO +VINYL SIDING AB SELECTED BY ONMER UWDI 8TAIR8 DOWN +r X FIBERGLASS BATT INSULATION MATCH HIGHEST EXISTING RIDGE +TYVEK HOUSE WRAP VN VAPOR BARRIEI41N8TALL +,2'COX PLYWOOD SHEATHING 2.X4'TIES a RAFTR-MATE'VENT BOARDS 72 +r x 4'8TUD8 Q 16'OC 4•-0•GC +VY SHEETROCK.TAPE,SPACKLE 8 PAINT --17+1- +R-,3 ARRIERA88 BATT INSULATION W/ N VAPOR BARRIER 2*X1'STUD WALL +12'SHEETROCKTAPE,SPACKLE&PAINT Q,MOC EXISTING rte' ATTIC L EXISTING OPEN TO FIRST ATTIC ARFA7 LOOR BELOW ,a-e'a- >4 W2-1 NEW NOTE: NEW FINISHED FLOOR ELEV TO BE r HIGHER (2)r X r HDR O THAN EXIST FINISHED FLOOR ELEVATION FOYY ER ALIGN WINDOW 2-1 WITH EXT.WALL CONSTRUCTION: DI EXISTING CENTER OF DOOR 1-4 BELOW +VINYL 9IDIN0 AS SELECTED BY OWNER CONTINUOUS r X4 KITCH BEDROOM +TYVEK HOUSE WRAP TYPICAL FLOOR CONSTRUCTION: BOTTOM PLATE(iYP) +1@'COX PLYWOOD SHEATHING +r X 10'FLOOR J8T8 @ 16'OC B +r X4 STUDS o 16.00 +R-19 FIBERGLASS BATT INSULATION W/ 2 +R,3 FIBERGLASS BATT INSULATION W/ VAPOR BARRIER L VAPOR BARRIER +3µ'PLYWOOD SUBFLOOR (2)r x M CCATREATED SPACKLE+,/2.SHEETROCK-TAPE, &PAINT .,mp< SELECTED BY TSILL ERMITE SHIELD TO °�� PARTIAL SECOND FLOOR PLA FLOORING SELECTED BY OWNER TAr DIAX 7LDTO CODE CRAWL SPACE lZ Rt6iO `nYFoFoAy tu.5XLAn.,3 1/r HO BO LONG (L2vio14-X1-GP-LAM ANCHOR BOLT(TVP) ExreTs•coNc m ?y N _ BLOCK FM BASEMENT EXI9Te•CONC yrjQOSTING FWEvroR PROPOSED EXTENSION @ O'BRIEN RESIDENCE BLOCKWALL * �P °�� 350 HICKORY ROAD, SOUTHOLD, NY 11971 MIN r THICK CONCRETE RAT SLAB * FIRST AND SECOND FLOOR PLANS 81 SECTIONS DOOR AND WINDOW SCHEDULE E CT I O N A A SECTION B B apROu 5494DRAWN BY: RWC DATE: JUNE 2002 SCALE: 1 /4"=1 '-OSFESSIONP Richard. W. Cuming, P.E. BellWt, New York 11713 (631) 286-3617 DWG 2 0 F PROPOSED NEW DORMER INSTALL CONTINUOUS INSTALL CONTINUOUS RIDGE VENT RIDGE VENT PROPOSED NEW DORMER INSTALL NEW ROOF SHINGLES III Ulu TO MATCH EXISTING INSTALL ALUMUNUM GUTTERS AND LEADERS AT ALL NEW ROOF EAVES MATCH EXISTING(TYPICAL) INSTALL SIDING AS SELECTED BY OWNF32 1111 11 1111 H 11 11 ❑ ❑ OCA � ❑ ❑ ❑ INSTALL SIDING AS SELECTED BY OWNER T, PROPOSED NEW ADDITION _I t• PROPOSED NEW ADDITION - WEST ( FRONT) ELEVATION SOUTH ELEVATION INSTALL CONTINUOUS PROPOSED NEW DORMER(FRONT) RIDGE VENT I'll 11 11 Il Y ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ELEVATION ELEVATION PROPOSED NEW ADDITION PROPOSED NEW ADDITION f PtE OF NEW p0 W. O� NORTH ELEVATION * P cGZ * PROPOSED EXTENSION OUTHOL , RESIDENCE EAST ( REAR) ELEVATION PARTIAL NO 350 HICKORY ROAD, TIONS LD, NY 11971 2'"�op5494° e`��� ELEVATIONS �OEfSS10NP�' DRAWN BY: RWC DATE: JUNE 2002 SCALE: 1/4"= V-0" Richard. W. Cumin, P.E. Bellport, New York 11713 (63 )286-3817 D W G 3 0 F