HomeMy WebLinkAbout28589-Z FORM NO. 4
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
Office of the Building Inspector
Town Hall
Southold, N.Y.
CERTIFICATE OF OCCUPANCY
NO: Z-30664 Date: 08/01/05
THIS CERTIFIES that the building ADDITIONS/ALTERATIONS
Location of Property: 350 HICKORY RD SOUTHOLD
(HOUSE NO. ) (STREET) (HAMLET)
County Tax Map No_ 473889 Section 54 Block 6 Lot 11
Subdivision Filed Map No. Lot No.
conforms substantially to the Application for Building Permit heretofore
filed in this office dated JULY 23, 2002 pursuant to which
Building Permit No. 28589-Z dated JULY 23, 2002
was issued, and conforms to all of the requirements of the applicable
provisions of the law. The occupancy for which this certificate is issued
is ADDITIONS & ALTERATIONS TO EXISTING SINGLE FAMILY DWELLING AS APPLIED
FOR.
The certificate is issued to JOANNE O'BRIEN
(OWNER)
of the aforesaid building.
SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL N/A
ELECTRICAL CERTIFICATE NO. 1110991 08/14/03
PLUMBERS CERTIFICATION DATED 01/08/03
or' ed S gnature
Rev. 1/81
Form No.6 _y`,•. �t `♦�-�t'r f
_TO YN-OF SOIITAOLD - -
BUILDING DEPARTMENT
TOWN HALL
765-1802 Z 8 ZQn�
APPLICATION FOR CERTIFICATE OF OCCUPANCY
This application must be tilled in by typewriter or ink and submitted to the Building Department with the following:
A. For new building or new use:
L Final sun ey of property with accurate location of all buildings, property lines, streets, and unusual natural or
topographic features.
2. Final Approval from Health Dept. of water supply and sewerage-disposal(S-9 form).
3. Approval of electrical installation from Board of Fire Underwriters.
4. Sworn statement from plumber certifying that the solder used in system contains less than 2./10 of I% lead.
5. Commercial building, industrial building, multiple residences and similar buildings and installations, a certificate
of Code Compliance from architect or engineer responsible for the building.
6. Submit Planning Board Approval of completed site plan requirements.
B. For existing buildings (prior to April 9, 1957) non-conforming uses,or buildings and"pre-existing" land uses-
1. Accurate survey of property showing all property lines, streets, building and unusual natural or topographic
features.
2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is
denied, the Building Inspector shall state the reasons therefor in writing to the applicant.
C. Fees
1. Certificate of Occupancy-New dwelling$25.00. Additions to dwelling$25.00, Alterations to dwelling$25.00,
Swimming pool $25.00, Accessory building$25.00, Additions to accessory building$25.00, Businesses $50.00.
2. Certificate of Occupancy on Pre-existing Building- $100.00
3. Copy of Certificate of Occupancy- $.25
4. Updated Certificate of Occupancy- $50.00
5. Temporary Certificate of Occupancy-Residential $15.00, Commercial $15.00
Date._
New Construction: Old or Pre-existing Building: i/ (check one)
Location of Property: 55 Al c ko: xi
y �j 501d/o
o /e(/
House No. I
(�Stre t Hamlet
Owner or Owners of Property: :Y0 a n P1 (/ r't e-n
�
Suffolk County Tax Map No 1000, Section ] -73 V1 Block Lot
Subdivision Filed Map. Lot:
Permit No. Date of Permit._ Applicant:_
Health Dept. Approval: Underwriters Approval:
Planning Board Approval:
Request for: Temporary Certificate Final Certificate: (check one)
Fee Submitted: $ �G �
Applicant Signature
cv� 30 Gf� y
FORM NO. 3
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
Town Hall
Southold, N. Y.
BUILDING PERMIT
(THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL
COMPLETION OF THE WORK AUTHORIZED)
PERMIT NO. 28589 Z Date JULY 23 , 2002
Permission is hereby granted to:
JOANNE O ' BRIEN
PO BOX 1533
SOUTHOLD,NY 11971
for
ADDITIONS AND ALTERATIONS TO AN EXISTING SINGLE FAMILY DWELLING AS
APPLIED FOR
at premises located at 350 HICKORY RD SOUTHOLD
County Tax Map No. 473889 Section 054 Block 0006 Lot No. 011
pursuant to application dated JULY 23 , 2002 and approved by the
Building Inspector to expire on JANUARY 23 , 2004 .
Fee $ 150 . 00
thor ze ignature
ORIGINAL
Rev. 5/8/02
a ��n�n�nrn��l-srn��l-�n�l-srn�s�nns s�rrr�l-r.��nn��n�s�nrnnrsrrs�n��n�I-�rnrs�ns�.nrrrrrs�r�rsr����nr..n�n�r�rs eo
5 BY THIS CERTIFICATE OF COMPLIANCE THE 5
5 NEW YORK BOARD OF FIRE UNDERWRITERS 5
5 BUREAU OF ELECTRICITY C5
Dj 40 FULTON STREET — NEW YORK, NY 10038 5
5 5 S
CERTIFIES THAT 5
5 Upon the application of upon premises owned by
5 55
5 5 T& B ELECTRIC JOANNNE O'BRIEN 5
8 DEBBIE LANE 350 HICKORY ROAD 5
5 PATCHOGUE NY, 11772 SOUTHOLD, NY 11971 5
C 5
Located at 350 HICKORY ROAD SOUTHOLD, NY 11971 5
5 Application Number: 1110991 Certificate Number: 1110991 5
Section: Block: Lot: Building Permit: 8DC: ns11 5
Described as a Residential occupancy, wherein the premises electrical system consisting of 5
5 electrical devices and wiring, described below, located in/on the premises at: 5
5 5 rrr5 Basement,First Floor, Outside, �5
A visual inspection of the premises electrical system, limited to electrical devices and wiring to the extent detailed 5
C� herein, was conducted in accordance with the requirements of the applicable code and/or standard 5
5 promulgated by the State of New York, Department of State Code Enforcement and Administration, or other
5 authority having jurisdiction, and found to be in compliance therewith on the Day of 5
14thDay 2003.
Name QTS Rate Ratine Circuit: Tyoe 5
5 Alarm and Emergency Equipment
5 Sensor 1 0 Carbon Monoxide 5
5 Sensor 5 0 Smoke 5
L5, Appliances and Accessories 5
5 Exhaust Fan l 0 F.H.P. c_
5 `wish ivasher 1 u 1.2 KW
5 Range 1 0 11.7 KW 5
5 Air Conditioner 1 0 48.000 BTU 5
5 Wiring and Devices 5
5 Receptacle 9 0 General Purpose 5
5 Switch 7 0 General Purpose 5
SFixture ll 0 Incandescent 5
Dimmers 6 0 5
5 Receptacle 1 0 20 amp Laundry
5 Receptacle 1 0 30 amp Dryer 5
5 Arc Fault Circuit Interrupter 1 0 15 amp 5
5 Receptacle 7 0 GFCI sea/ �+
5 Service 5
Continued on Next Page 1 of 2 r5
I� This certificate may not be altered in any way and is validated only by the presence of a raised seal at the location indicated.
55
D rJ'rJ'rJLL.Pd'L3 r PLrEJrJr3f�r�r�r nr�rE'r] 701 1 o
o �n�nu�srs������nnsss���sr��sss��rr�rsOr, .n rrro
5 BY THIS CERTIFICATE OF COMPLIANCE THE
5 NEW YORK BOARD OF FIRE UNDERWRITERS 5
5 BUREAU OF ELECTRICITY c5
55 40 FULTON STREET — NEW YORK, NY 10038 5
5 CERTIFIES THAT 5
Upon the application of upon premises owned by
5 T & B ELECTRIC JOANNNE O'BRIEN
5 5 8 DEBBIE LANE 350 HICKORY ROAD
PATCHOGUE NY, 11772 SOUTHOLD, NY 11971 5
Located at 350 HICKORY ROAD SOUTHOLD, NY 11971
5 Application Number: 1110991 Certificate Number: 1110991 5
c 5
5 Section: Block: Lot: Building Permit: BDC: ns11 r�+
Described as a Residential occupancy, wherein the premises electrical system consisting of 5
5 electrical devices and wiring, described below, located in/on the premises at: 5
Basement, First Floor, Outside.
5
5 5
5 A visual inspection of the premises electrical system, limited to electrical devices and wiring to the extent detailed 5
5 herein, was conducted in accordance with the requirements of the applicable code and/or standard 5
5 promulgated by the State of New York, Department of State Code Enforcement and Administration, or other 5
5 authority having jurisdiction, and found to be in compliance therewith on the Day of 5
5 loth August, 2003. 5
5 5 Name QTY Rate Rating Circuity Type 5
I Phase 3 W Service Rating 200 Amperes [5
5 Service Disconnect: l 200 cb rr5
5 hieters: l 5
5 5
5 5
5 5
5 5
5 Li
Sea/ S
5 2 of 2 5
cl This certificate may not be altered in any way and is validated only by the presence of a raised seal at the location indicated. JM
5 �cnrc nrPrJ� rrcn rJ ar�rrur�r�rr�cJ a cn rJ a rJ a cfL3PL
o�gpFFO(,�co
N Z
Town Hall.53095 Main Road Op Fax(631) 765-9502
P.O. Box 1179 y7�1 �aO� Telephone (631) 765-1802
Southold, New York 11971-0959
BUILDING DEPARTMENT
TOWN OF SOUTHOLD
CERTIFICATION
Date:
Building Permit No. 2' F,s S 9
Owner: j0 '4'f f— Q &&XW
(Please print)
Plumber: rat A i1 ji� IS ' / F�t ig
(Please print)
I certify that the solder used in the water supply system contains less than 2/10 of 1°%
lead.
(Plumbers Signature)
Sworn to before me this
day of afJiA1 . 2005
Notary Public, County
��D�� JEAN GUIDO
Netary Public,State of New York
Ab.01ryU6077147-Suffolk Cou*
TermEwkn 7•Q•c)6
M-1802
BUILDING DEPT.
INSPECTION
1111",
FOUNDATION IST [ ] ROUGH PLBG.
FOUNDATION 2ND [ ] INSULATION
[ ] FRAMING [ ] FINAL
[ ] FIREPLACE A CHIMNEY
REM KS: �'..-
1
J _
e
DATE ��{ 7� INSPECTOR
suiLnINc DEPT.
INSPECTION-
FOUNDATION
IST [ ROUGH PLBG.
[ ] FOUNDATION 2ND [ ] INSULATION
[ ] FRAMING [ ] FINAL
[ ] FIREPLACE 8 CHIMNEY
REMARKS: k-Ltn
DATE INSPECTOR � �
M-iso2
suiLDiNa car.
INSPECTION
[ ] FOUNDATION IST [ ] ROUGH PLBG.
[ ] F DATION 2ND [ ] INSULATION
[ FRAMING [ ] FINAL
[ ] FIREPLACE & CHIMNEY
REMARKS: l�✓C�.��2 _ (1`��
DATE IN8PECT0 _
V2"
765-1802
BUILDING DEPT.
INSPECTION
[ ] FOUNDATION IST [ ] ROUGH PLBG.
[ ] FOUNDATION 2ND [j'J INSULATION
[ ] FRAMING [ ] FINAL
[ ] FIREPLACE 8 CHIMNEY
REMARKS:
zi
rys .
DATE d'/ INSPECTOR <����
M.1802
suauINc DE".
INSPECTION
[ ] FOUNDATION IST [ ] ROUGH PLBG.
[ ] FOUNDATION 2ND INSULATION�<c�,
[ ] FRAMING [ ] FINAL
[ ] FIREPLACE & CHIMNEY
REMARKS:
DATE ��'�13 INSPECTOR—l��fY�v` ,
ass-ieo2
suaoINc oar.
INSPECTION
[ ] FOUNDATION IST [ ] ROUGH PLBG.
[ ] FOUNDATION 2ND [ ] 1 CATION
[ ] FRAMING [ FlNAL
[ ] FIREPLACE & CHIMNEY
REMARKS: C22� -c-.a
DATE v'u p'3 INSPECTOR
BUILDING PERMIT EXAMINER CHECK LIST
DATE REVIEWED: 77-//,�,5/02
APPLICANT: u, _( ft; z� DATE SUBMITTED: 02
SCTM#DISTRICT: 1,000, SECTION: , BLOCK: , LOT:
STREET ADDRESS y . CITYcx SUBDIVISION: NA
xq4.
PROJECT DESCRlPTION: A ;
ESTIMATED PROJECT COST: ARCHITECT4ESE R:( )MjAa�) FAST TRACK? A0
SINGLE & SEPARATE CERTIFICATION-REQUIRED? � NOTES:
LOTS 40,000SF-100-24.Lot recognition.(CREATED before June 30,1983),UNDERSIZED LOTS FROM JAN.1997 100-25.Merger.(A nonconforming at any time after 7/1/,
ZONING DISTRIC CONFORMING?
REQ. LOT SIZE'//J,DOD ACT. LOT SIZE:,Z Z REQ. LOT COV ACT. LOT COV. d`
REQ. FRONT S PROP. FRONT /OQ SIDE /D ACT. SIDE
REQ. REAR �=� PROP. REAR _ REQ. HEIGHT PROP. REICHT
WATER FRONT? DESCRIPTION:
PANEL #: jA__ FLOOD ZONE: ,
APPROVALS REQUIRED
SUFFOLK COUNTY HEALTH DEPT: YES orep, (BED #): DTE: PERMIT PERMIT#:R10-
TOWN SEPTIC RECEIPT: Y ore AkpNL l r'rt- phi'
NEW YORK STATE DEC: PRE-DEC 9/1/75 YES orev
SOUTHOLD TOWN TRUSTEES: YES o
TOWN ZONING BOARD APPROVAL: YES or
TOWN PLAN. BOARD APPROVAL: YES o
TOWN HISTORICAL PRE (SPLIA): S or
NYS ENERG VYE OR NO EGRESS (18 4 sq total) ..•�'VE (SQ. FT. x 4%) LIGHT (SQ. FT. x 8%)
BUILDING PERMITS OPEN/EXPIRED: BP -Z/C/0 Z- ,
HAVE PRE CO'S : Y OR N BP -Z/C/o Z- ,
NOTES: i-rrA_A^,
FEE STRUCTURE: FOUNDATION: SF
FIRST FLOOR: `fes g' SF
SECOND FLOOR: f,'Z SF
OTHER: SF INIT OTHER TOTAL
TOTAL: 7&I SOO SF FEE FEE
A
1. ( SF)- SF)= SFX$ =$ +$ +$ _ $
2. ( SF)-( SF)= SFX$ =$ +$ +$ = $
NOTE: APPLY
26 WATERPROOFING TO ALL
EXTERIOR SURFACES OF CONC
P BLOCK BELOW GRADE
(2) 2" X 6" CCA TREATED —(l)CA TREATED SIX 4'f
SILL PLATE W/ METAL
TERMITE SHIELD TO PLATE W/ METAL
CODETERMITE SHIELD TO
CODE
2" X 10" FLR JSTS 1/2" DIA X 12" LONG
ANCHOR BOLT (TYP)
0 8"H X 12" W 8"H X 6" W CONC
iv CONC BLOCK 1--0., o ? BLOCK-TIE TO
FLOOR JSTS W/
MASONRY TIES
OF NE,y
y�PtE YOF
2" THICK CONCRETE RAT SLAB SPR° W.
ZA,hMIN °oma
* G C
QFC NO. 54940 (3'
.� �OFES 10
PROPOSED EXTENSION FOR O'BRIEN RESIDENCE
350 HICKORY ROAD, SOUTHOLD, NY 11971
REVISED FOUNDATION DETAIL
DRAWN BY: RWC DATE: NOV. 2002 SCALE: 3/8"=1 '-0"
Richard. W. Cuming, P.E.
Bellport, New York 11713 (631) 286-3617 DWG 1 0 F 1
Richard W. Cuming, P. E.
28 Bellhaven Road
Bellport, New York 11713
(631) 286-3617
July 12, 2002
Town of Southold
Building Department
Main Road
Southold, New York 11971
Re: Proposed Extension to O'Brien Residence
350 Hickory Road,
Southold, New York 11971
To Whom It May Concern:
The attached construction plans and application for a building permit request
approval for the construction of an extension to and renovations of an existing two (2)
bedroom residence which will result in the addition of one (1) bedroom to the existing
structure.
I hereby certify that the existing sanitary disposal system for this residence should
be adequate to treat additional wastewater which might potentially be generated as a
result of the additional bedroom.
If you have any questions, please do not hesitate to call.
Sincerely,
5 L LE, OF NEIV J-OO. Richard W. Cuming, E.
! R0 W.
r
C? �
/� 'FESSiOti'�F
Permit Number
MECcheck Compliance Report Checked By/Date
New fork State Energy Conservation Construction Code
MECcheck Software Version 3.3 Release lc
Data filename: C:\Program Files\Check\NffiCcheck\J. O'Brien Energy Calcs.cck
TITLE: Proposed Extension @ O'Brien Residence
COUNTY: Suffolk
STATE: New York
HDD: 5750
CONSTRUCTION TYPE: Detached 1 or 2 Family
HEATING TYPE Non-Electric
DATE: 07/18/02
DATE OF PLANS: June 2002
PROJECT INFORMATION:
Joanne O'Brien Residence
350 Hickory Road
Southold, NY 11971
COMPANY INFORMATION:
Richard W. Curring, P. E.
28 Bellhaven Road
Bellport, NY 11713
COMPLIANCE Passes
Maximum UA= 101
Your Home= 101
0.0%Better Than Code
Gross Glazing
Area or Cavity Cont. or Door
Perimeter R-V a R-ValueU Factor ILA
Ceiling 1: Cathedral Ceiling(no attic) 362 19.0 0.0 18
Skylight L Wood Frame, Double Pane with Low-E 18 0.340 6
Wall 1: Wood Frame, 16" o.c. 576 13.0 3.0 35
Window I Wood Frame, Double Pane 21 0.340 7
Door I: Glass 39 0.320 12
Door 2: Solid 1111, 0 340 6
Floor I: All-Wood JoisttTruss, Over Unconditioned Space 362 190 0.0 17
COMPLIANCE STATEMENT. The proposed building represented in this document is consistent with the building
plansspecifications, and other calculations submitted with this permit application. The proposed systems have been
designed to meet the New York State Energy Conservation Construction Code requirements When a Registered
Design Professional has stamped and signed this page, they are attestine that to the best of his/her knowledge, belief,
and professional judgment, such plans or specifications are in compliance with this Code.
BuilderlDesigner ��.C�.�..�,1-__ _ ` Date--7/—ul—oZ___..
OF NEW yo
5 P�D W. 0 R�
r i �
cf W
2
54 940
N
v
SSIWAP
MECcheck Inspection Checklist
New Fork State Energy Conservation Construction Code
MECcheck Software Version 3.3 Release lc
DATE 07 1S 02
TITLE. Proposed Extension @ O'Brien Residence
Bldg.
Dept
Use
I
Ceilings:
[ ] I Ceiling 1: Cathedral Ceiling(no attic), R-19.0 cavity insulation
Comments.
I
Above-Grade Waits:
[ ] 1. Wall L Wood Frame, 16" o.c., R-13.0 cavity+R-3.0 continuous insulation
Comments
I
Windows:
[ ] 1. Window 1: Wood Frame, Double Pane, U-factor: 0340
For windows without labeled U-factors, describe features:
#Panes_Frame Type Thermal Break? [ ] Yes[ ]No
Comments
I
Skylights:
[ ] 1. Skylight ]: Wood Frame, Double Pane with Low-E, U-factor: 0.340
For skylights without labeled U-factors, describe features
#Panes_Frame Type Thermal Break? [ ] Yes[ ] No
Comments:
I
Doors:
[ j I Door 1: Glass, U-factor. 0 320
#Panes_Frame Type Thermal Break? [ ] Yes[ ]No
Comments:
[ j 2. Door 2Solid, U-factor: 0.340
Comments:
I
Floors:
[ ] 1. Floor l: All-Wood Joist/Truss, Over Unconditioned Space, R-19.0 cavity insulation
Comments:
Air Leakage:
[ ] Joints,penetrations, and all other such openings in the building envelope that are sources of air
leakage must be sealed
[ ] Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air-tight assembly
with a 0.5" clearance from combustible materials If non-IC rated, the fixture must be installed with a
3" clearance from in;uLltion
I
Vapor Retarder:
[ ] i Required on the warm-in-"niter side of all non-vented framed ceilings, walls, and floors.
I
i Materials Identification:
[ ] Materials and equipment must be installed in accordance with the manufacturer's installation instructions
[ ] Materials and equipment must be identified so that compliance can be determined.
[ ] Manufacturer manuals for all installed heating and cooling equipment and service water heating
equipment must be provided
[ ] Insulation R-values and glazing U-factors must be clearly marked on the building plans or specifications.
I
Duct Insulation:
[ ] Supplv ducts in unconditioned attics or outside the building must be insulated to R-8
[ ] I Return ducts in unconditioned attics or outside the building must be insulated to R-4.
[ ] I Supply ducts in unconditioned spaces must be insulated to R-8.
[ ] Return ducts in unconditioned spaces(except basements)must be insulated to R-2.
I Insulation is not required on return ducts in basements.
I
Duct Construction:
[ ] I All joints, seams, and connections must be securely fastened with welds, gaskets, mastics
(adhesives), mastic-plus-embedded-fabric, or tapes. Duct tape is not permitted.
Exception: Continuously welded and locking-type longitudinal joints and seams on ducts
I operating at less than 2 in. w.g. (500 Pa).
[ ] I Ducts shall be supported every 10 feet or in accordance with the manufacturers instructions
[ ] I Cooling ducts with exterior insulation must be covered with a vapor retarder.
( ] I Air filters are required in the return air system.
[ ) I The HVAC system must provide a means for balancing air and water systems.
I
Temperature Controls:
[ ) I Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space
temperature set point of the largest zone.
I
I Electric Systems:
[ ] I Separate electric meters are required for each dwelling unit.
I
Fireplaces:
[ ] I Fireplaces must be installed with tight fitting non-combustible fireplace doors.
[ ) Fireplaces must be provided with a source of combustion air, as required by the Fireplace construction
provisions of the Building Cotte of New York Stale,the Residential Code of New York State or
the New York Citi.Building Code, as applicable.
I
Service Water Heating:
[ ] I Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the
water heater has an integral heat trap or is part of a circulating system.
[ ] I Insulate circulating hot water pipes to the levels in Table 1.
I
Circulating Hot Water Systems:
[ ] I Insulate circulating hot water pipes to the levels in Table 1.
I
Swimming Pools:
[ ) I All heated swimming pools must have an on/off heater switch and require a cover unless over 20%
of the heating energy is from non-depletable sources. Pool pumps require a time clock.
I
Heating and Cooling Piping Insulation:
[ ] FIVAC piping conveying fluids above 105 OF or chilled fluids below 55 OF must be insulated to the
lesels ut Table '
Table l: Minimum Insulation Thickness for Circulating Hot Water Pipes.
Insulation Thickness in Inches by Pipe Sizes
Heated Water Non-Circulative Runouts Circulating Mains and Runouts
Temperature LF) Up to I" UP to 1.25" 15" to 2 0" Over 2"
170-180 01 1.0 L5 20
14o-160 05 0 S l u 1.5
100-130 0.5 0 5 OS 1.0
Table 2: minimum Insulation Thickness for HVAC Pipes.
Fluid Temp. Insulation Thickness in Inches by Pipe Sizes
Piping System Types R_an�F.e( F) 2" Runouts V and Less 1 25" to 2" 2_5"to 4"_
Heating Systems
Low Pressure/Temperature 201-250 LO 1.5 1.5 20
Low Temperature 120-200 0.5 1.0 1.0 1.5
Steam Condensate(for feed water) Any 1.0 1 0 1 5 20
Cooling Systems
Chilled Water, Refrigerant, 40-55 05 0 -' 075 1.0
and Brine Below 40 1 0 LO 1.5 1.5
NOTES TO FIELD(Building Department Use Only)
n , I.
A � n
FIELD INSPECTION REPORT DATE COIVT3
` Y
-- w
FOUNDATION DIST
71
----------------- - -
-- _ j II:
FOUNDATION k2NDi
✓y
ry
i
ROUGH FRAMING d-
PLUNIBING y
I
ii�s&�a3 S
INSULaTION PER N.�'. ,
STATE ENERGY COLE
i /L Gcrua�
,
i
FINAL
ADDITIONAL CONMENfS
O
ZE
Z
m
—f—f f�ff f
—1
� I
I z
�" yl
zl
i = li
TI
� I
y
� J
TOWN OF SOUI'HOLD BUILDING PERMIT APPLICATION CHECKLIST
BUILDING DEPARTMENT Do you have or need the following,before applying
TOWN IIALL Board of Health
SOUTHOLD, NY 11971 3 sets of Building Plans s/
TEL: 765-1802 Survey
PERMIT NO Check .ft 115 y
Septic Form
N.Y.S.D.E.C.
2 Trustees
Examined lt5 20 L Contact:
Approved z ,20_ - Mail to:
Disapproved a c
Phone:
- uild ' Inspector
L_ 1 APPLICATION FOR BUILDING PERMIT
L '-- -- - -
Date Jt/L-y 1Z— , 200Z-
INSTRUCTIONS
pOZINSTRUCTIONS
a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 3
sets of plans, accurate plot plan to scale.Fee according to schedule.
b- Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or
areas,and waterways.
c. The work covered by this application may not be commenced before issuance of Building Permit.
d. Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit
shall be kept on the premises available for inspection throughout the work.
e.No building shall be occupied or used in whole or in part for any purpose what-so-ever until a Certificate of Occupanc}
is issued by the Building Inspector.
APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the
Building Zone Ordinance of the Town of Southold, Suffolk County,New York, and other applicable Laws, Ordinances or
Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described.The
applicant agrees to comply with all applicable laws,ordinances,building code,housing code, and regulations, and to admit
authorized inspectors on premises and in building for necessary inspections.
(Signature of applicant a ame,if a cotporauon)
S5 BEu.NA-JE.i Ro
(Mailing address of applicant)
State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician,plumber or builder
��J�e�JFf51L.
Name of owner of premises J0A0A O S2t£r,)
(as on the tax roll or latest deed)
If applicant s a corporation, signature of duly authorized officer
(Name and title of corporate officer)
Builders License No.
Plumbers License No.
Electricians License No.
Other Trade's License No.
1. Location of land on which proposed work will be done:
3550 WtcK0V_q eo,pQ SoU tNa41�
House Number Street Hamlet
County Tax Map No. 1000 Section OSS- Block (w Lot L
Subdivision Filed Map No. Lot
(Name)
2. State existing use and occupancy of premises and intended use and occupancy of proposed conshnction:
a. Existing use and occupancy. S1rY Lt ter►itr �t ��Sinf�t=1+!¢.
b. Intended use andoccapancy S�aJGtf Fp►1/t4 i2€Stl ,tl)+1e,
3. Nature of work(check which applicable):New Building Addition__L/_Alteration 1/
Repair Removal Demolition Other Work
(Description)
4. Estimated Cost # J� 000 Fee
(to be paid on filing this application)
5. If dwelling, number of dwelling ups Number of dwelling units on each floor
If garage, number of cars A704 ))
6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. i11 A
Dimensions of existing structures, if any: Front �D �� - Rear Sa-G 4`f-1 Depth e4 i4„
Height /8` Number of Stories _✓Arts
Dimensions. of s me structure with alterations or additions: Front 63� �l Rear
Depth 36-C" *- M 1C Height J8 t y Number of Stories
8. Dimensions of entire new construction: Front /.3 Rear /3-4* Depth 8"
Height /8 ` x" Number of Stories_ /
9. Size of lot: Front _1001 Rear /00,06 ' Depth /ZS,Z7�►!3!,8/ ✓R�r E S)
10. Date of Purchase 167 gZ Name of Former Owner OL-0 FikQ
11. Zone or use district in which premises are situated 12-40
12. Does proposed construction violate any zoning law, ordinance or regulation: /JO
13. Will lot be re-graded-_-A/0 Will excess fill be removed from premises: a NO
14. Names of Owner of premisesJOVIA 0'aX+C_Address3�PW0t11_ 0 Soo�h ne No. G51-'7/.5- 1456
Name of Architect RhR-0
ieHid g A E. Address?68Fi A4u1J'90 k�b one No 631-Z86 3617
Name of Contractor Address Phone No.
15. Is this property within 100 feet of a tidal wetland? *YES NO i//
• IF YES, SOUTHOLD TOWN TRUSTEES PERMITS IALAY BE REQUIRED
16. Pro;ide sun-ey, to scale, with accurate foundation plan and distances to property lines.
17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey.
STATE OF NEW PORK)
SS:
COUNTY OF )
Li being duly sworn, deposes and says that(z)he is the applicant
(Name of mdi-,idual signing contract)above named,
(9)He is the f T
(Contractor, Agent, Corporate Officer,etc.)
of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;
that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be
performed in the manner set forth in the application filed therewith.
Sworn to before me this
L
day of 20 il_
AU
No Public Signature of Appli
-�70Z 'Lo 6eW sandx3 uwss1wwo3 ,
f4unoo nesseN u1 pagllenp
L9Z9964•ON
voAMaN to%Ens'onand AmvioN
N018NM39 3Ntl1U
t: MAP OF_.�PQ0 P E4TY
tLi - - - -
SU2VEYED FOr2.
r : 3 JOANNE O' E321E i,\1
BERGAN I AT
m � SOUTHOLD
TOWN OF SQUTi-{OLD.KY,
g 4i o
ci
. 9 39'
VY
8
L „ ^ 3
W N p LL
Iid LLQ ; o
� � N
b SIC ALE = 40'• !"
2Z / G'IRON PIPE
;4 �g' 0" p„WUNUMENT
I 7
TITLE NO.- 56&0258
'50' IGIRINCIC /
0"UMORILM ALTIKAIION OR AMIRt
IO THIS SURVEY IS A VIOLATION Of
PCTIOM 7209 OF THE NEW TOY(STAn
WDCATION LAW. GUARANTEED Tl_, JOANNE O'B21E'N SECUrCTY TITLE.
—
CAPIES OF THIS SURVEY MN NOT REARUq AND GUARANTY '-.�. AND 7i THE 0',i THC)L-, -;-� V�5
M LAND SURVEYOR'S INKED ,
SEAL OR -- �' -- -
LVAOSSFD SEAL SHALL NOT M CONSIDERED BAN K — _A5 SUr2 V_E'Y_E O — h:i,'✓,t jCC,,i3�
.. r T
GU IEA VALID TRUE COPY, i'J I -VA�� / IJI � L EPC M
ONLY T IIIS INDICATED HEREON SHALL RUN i`.•.J •C` :` Y '
SUFI- CO,TAX MAP DATA IIPREPARED,EAND SON HIS SEHON FOR OLF TOTHE
[YFI _
TITLE COMPANY, GOVE[.NMENTAL AGENCY AND -
/� LENDING RESTITUTION LISTED HEREON, AND
TO ME ASSIGNEES Of THE LENDMG INSTI � -.S�s `�— ) 5•LJ V , / /
TUITION.'GUARANTEES ARE NOT TRANS"—
yo ADDITIONAL R
RAIWE•,.^oAoomaEALR m,uv,w ^R TI,L.. LIC. AND SURVEYORS - GREEfNPORT NY.
SOUND VIEW AVE. A
2
134•
r� I 94r s-r• 1'4r
Uj
4 4
REMOVE EXISTING r X e'ROOF
RAFTERS,ROOF SHEATHING
o �t� B'X te•FDTN VENT SHOWN ROOFING
EXISTINEXTEG TS
INSTALL TEMPORARY SUPPORT
a4' (TYPICAL FOR4) KffCHEN AREA ONLY WALL A8 SHOWN PRIOR TO
G ROOF
N RAFTERS ANREMOVAL OFD CEI NO JOISTS
r RAT SLAB
® IlJ
N Oro 49'40'E 1�•� b / EXISTING
ATTIC
JJrr REMOVE EXISTING r X E•CEILING
' 7Yf" JOISTS,SHEETROCKAND INSULATION
$ )y (2)1 a•x l4"GP-tAM / E rr (� ITGOrEXTENTSHEN AREA ABOVE EXISTING
dpi � ti � �
EMOTING Eurnme
CONSTRUCT POCKETS KITCHEN BEDROOM
HOLD 4• (2)IN FDTN WALLS TO G�
PROPOSED 13'--C X 2r-W RECEIVE NEW GIRDER, 'Y i
APPROX4•XMX12' f� I
ADDITION DEEP-GROUTISHIM y '
GIRDER AS REQUIRED ,
EXISTING
EXISTING
V�VLSPACE EXISTING CONCRETE BLOCK FDTN rt fi CONIC
V ; m ON r X Ir PTO(CONTRACTOR TO EDG
BOCK FDTN
_ VERIFY IN FIELD) b �.' EXISTING
b N X ap i' BASEMENT EIISTWCON°
4 tv N BLOCK WALL
z q7m
84ro 4Ir4D•W 131.81' rJr s-0• sem• r oT
PLOT PLAN 1T- REMOVALS SECTION
SCALE: 1" =20' A SCALE: 1/4"= 114r
. 2
EXISTING BRICK CHIMNEY ON CONCRETE EXISTING DECK
FOUNDATION-CONTRACTOR TO VERIFY DEPTH
OF FDTN AND PROTECT AS REWIRED
GENERAL NOTES AND REMOVE EXISTING WINDOW AND LTJ/
FOUNDATION PLAN IN DO F &WINDOW INDICATED
IN DooR a WINDOW REMOVE SECION OF EXISTING DECK
SPECIFICATIONS 9CMEDULE FRAMEIN OPENING OF NECESSARY PROJECTTOTOC ORIGINAL
CT CONDITION
AND FINISH AS SHOWN ON FIRST FOUNDATION-RESTORE DECK AT END
SCALE: 1/4• = 1'-0' FLOOR PLAN OF PROJECT TO ORIGINAL CONDITION UNDER,01TERS CERTIFICATE
REQUIRED
REMOVE EXISTING*LINING
DOOR AND FRAME-REINSTALL PL UAIRER CFRTOF/CAT/ON AP R VEDAS NOTED
1. ALL WORK SHALL CONFORM TO NEW YORK STATE AND LOCAL BUILDING CODES. AS INDICATED IN DOOR a ON LEAD CONTENT BEFORE DATE' P.J
WINDOW SCHEDULE CERTIFICATE OF OCCUPANCY FEE: � BY'
2. ALL WORK SHALL CONFORM TO NEW YORK STATE ENERGY CONSERVATION CODE.
3. ALL ELECTRICAL WORK SHALL BE FIRE UNDERWRITERS INSPECTED AND APPROVED. SOLDER USED /N I l/ATER NOTIFY UI AM T DEPARTMENT AT
4. CARRYALL FOUNDATIONS DOWN TO UNDISTURBED EARTH HAVING A MINIMUM BEARING SUPPLY 2110FOUI CANNOT 765.1802 9 AM To 4 PM FOR THE
CAPACITY OF 2 TONS PER SQUARE FOOT. NOTIFY ENGINEER IMMEDIATELY IF UNSUITABLE SOILS OT FOLLOWING INSPECTIONS:
F-xCEED 2/7Q ULA% LEAD. t. FOUNDATION - TWO REQUIRED
REMOVE EXISTING EXTERIOR FOR POURED CONCRETE
EXIST. WALL ro uMrrs SHOWN-FRAME PLUMBING 2. ROUGH - FRAMING & PLUMBING
5. CONCRETE FOR FOOTINGS, FOUNDATIONS AND SLABS-ON-GRADE GRADE 3HAlL HAVE BA
-0IN MUSTTH �+
COMPRESSIVE STRENGTH OF 3,000 PSI AT 28 DAYS AND SHALL CONFORM TO THE LATEST NEW OPENING LA SHOWN ON ALL WATER
LINE NEED 3. INSULATION
FIRST FLOOR PLAN aNG Efl LINES NEED A FINAL - CONSTRUCTION MUST
REQUIREMENTS OF ACI 318. TESTING BEFORE COVERING BE COMPLETE FOR C.O.
8. CONCRETE BLOCK FOR FOUNDATIONS SHALL BE HOLLOW, LOAD-BEARING, CONFORMING TO THE ALL CONSTRUCTION SHALL MEET
EXIST BEDROOM EXIST BEIXi00M REMOVE EXISTING WINDOW-PRAME THE E REQUIREMENTS OF THE N.Y.
LATEST REQUIREMENTS OF ASTM C-9O. IN OPENING AND FINISH AS SHOWN STATE CONSTRUCTION & ENERGY
7. FRAMING LUMBER SHALL BE DOUGLAS FIR, NO. 2 GRADE OR BETTER,WITH A MINIMUM BASE ON FIRST FLOOR PLAN If copper tubing is used CODES. NOT RESPONSIBLE FOR
VALUE EXTREME FIBER STRESS IN BENDING OF 850 PSI. WOOD MEMBERS IN CONTACT WITH for water distributing DESIGN OR CONSTRUCTION ERRORS
CONCRETE OR MASONRY, USED FOR EXTERIOR DECKS OR PLATFORMS, OR WHERE INDICATED ON REMOVE EXISTINGOPENINGS
WINDOWSELECTIC sySityp piping shall be
THE PLANS, SHALL BE SOUTHERN YELLOW PINE, CCA TREATED TO A RETENTION OF 0.40. FRAMING FINISH AS IN OW NIN FIRST EXISTING PANEL TO RWrt of types I< or L only
FINISH AS BROWN ON FIRST BREAKER PANEL TO REMAIN-
EXIST
PROVIDE S MO�E-DETECTING
SHALL BE N0. 2 GRADE OR BETTER AND DECKING SHALL BE N0. 1 GRADE OR BETTER WHERE FLOOR PLAN EXIST HALLWAY CONTRACTORTOPROTF% EXIST DEN UNDERWRITERS CERTIFICATE ALARM DEVICES
21.1
SHOWN ON THE PLANS, EXTERIOR POSTS, RAILINGS AND/OR DECKING SHALL BE CONSTRUCTED WITH REQUIRED AS TO PART. CO
WESTERN RED CEDAR, NO. 1 GRADE. N.Y.S BUILDING CODE.
S. HEADERS SHALL BE SIZED AS SHOWN ON THE PLANS AND/OR IN THE DOOR AND WINDOW PROVIDE SHOO C PRE AND/OR
SCHEDULE. WHERE NOTED, HEADERS, RIDGE BEAMS, GIRDERS, VALLEY AND/OR HIP RAFTERS SHALL THERMAL SNOOK PREVENTING
BE CONSTRUCTED WITH G-P LAM LVL (LAMINATED VENEER LUMBER)BEAMS AS MANUFACTURED BY DEVICES TE TO PART. CODE- PROVIDE COPENINGSSOAP FOR
GEORGIA-PACIFIC. ALL MANUFACTURER'S RECOMMENDED INSTALLATION PROCEDURES SHALL BE N.Y. STATE BUILDING CODE. EMERGENCY ESCAPE AS
EXIST KITCHEN REQUIRED BY PART. 714 OF
COMPLIED WITH.
9. DOUBLE FLOOR JOISTS SHALL BE INSTALLED UNDER ALL INTERIOR PARTITION WALLS RUNNING N.Y. STATE BUILDING CODE.
PARALLEL TO THE JOISTS. SKYLIGHT OPENING IN ROOF SHALL BE FRAMED WITH DOUBLE ROOF EXIST STORAGE EXIST DINING ROOM
RAFTERS ON BOTH SIDES AND DOUBLE HEADERS TOP AND BOTTOM. OR
10. THE CONTRACTOR IS RESPONSIBLE TO PROTECT THE EXISTING STRUCTURE AND ITS CONTENTS OCCUPANCYS UNLAFU
AT ALL TIMES FROM EXPOSURE TO THE WEATHER.WHERE EXISTING WALLS OR OTHER STRUCTURAL USE )S CERTIFICATE L
ELEMENTS ARE SHOWN TO BE REMOVED, TEMPORARY SUPPORTS AS REQUIRED SHALL BE REMOVE EXISTING WINDOWS WITHOUT CERTIFICATE
INSTALLED PRIOR TO THE REMOVALS. DISINGCONICDECK (3KRAMENEW OPENINGS AS OF OCCUPANCY Jr/'
11. THE CONTRACTOR AND ALL OF HIS SUBCONTRACTORS SHALL BE LICENSED AND INSURED TO REWIRED FOR NEW DOOR AND "`E °F "EIv `
PERFORM THE WORK OF THIS PROJECT AS REQUIRED BY THE LOCAL GOVERNING JURISDICTION. SCHEDULE)(SEE DOOR a WINDOW °
12. THE CONTRACTOR SHALL VISIT THE PROJECT SITE PRIOR TO THE START OF CONSTRUCTION IN SOHEDULE) * 5 �PR� W
REMOVE EXISTING WINDOWS ` 2 * PROPOSED EXTENSION Q O'BREN RESIDENCE
ORDER TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS. HE SHALL REPORT ANY NEW OPENING FOR NEW WINDOWS DooR FRAME IN OPEN NI °AND c "
DESCREPANCIES BETWEEN THE PLANS AND HIS FINDINGS TO THE ENGINEER IN WRITING PRIOR TO AND FlNLO RPLAINDERA88HOVNON FINSH AS SHOWN ON FIRST i T ' �W 350 HICKORY ROAD, SOUTHOLD, NY 11971
THE START OF CONSTRUCTION. FlRSrFoRAN
13. THE CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR ALL MEANS AND METHODS OF FL °p N�' 5494 �� PLOT PLAN, REMOVALS PLAN & SECTION
pFessioaP FOUNDATION PLAN, GENERAL NOTES Er SPECIFICATIONS
CONSTRUCTION AND SHALL ADHERE TO ALL APPLICABLE SAFETY STANDARDS AND REGULATIONS. °
FIRST FLOOR REMOVALS PLAN DRAWN BY: RWC DATE: JUNE 2002 SCALE: AS SHOWN
3CALE: 1/4" = ,'-0 Richard. W. CuminC�T P.E.
Bellport, New York 11713 (831) las-3817 DWG 1 OF 3
ADOOR & WINDOW SCHEDULE
2
��. MARK NO. OF DESCRIPTION HEADER
NUMBER UNITS SIZE
W1-1 D1-1 1 REINSTALL EXISTING W-W x 8'-8" SLIDING PATIO DOOR AND FRAME AT LOCATION (2)2"X W
1rd' SHOWN. CONTRACTOR TO VERIFY ROUGH OPENING REQUIRED.
NEW DINING AREA D1.2 1 2'-8•X8'-8' PREHUNG EXTERIOR STEEL DOOR, THERMA-TRU MODEL NO. 282 OR (2)2"X 8"
a EQUAL,WITH EXTERIOR LOCKSET AND DEADBOLT KEYED ALIKE WITH EACH
EXISTING DECK b OTHER AND WITH DOOR D7-4.
D1-3 1 ONE(1) PAIR OF WOOD BIFOLD DOORS, EACH 3'-0•X 8'-8•,WITH SIFOLD DOOR (2)2'X 6'
HARDWARE. DOORS TO BE 1/3 SOLID PANEL AND 213 LOUVERED.
I: 1-
s3 VLXbHr E DI-41 W-W X 8'-8" PREHUNG EXTERIOR STEEL DOOR, THERMA-TRU MODEL NO. 530, (2)2"X 8'
ss r WITH MODEL NO. 530SL 14"WIDE SIDELIGHT OR EQUAL,WITH EXTERIOR
LOCKSET AND DEADBOLT KEYED ALIKE WITH EACH OTHER AND WITH DOOR D1-2.
D1-5 1 Z-W X V4r PREHUNG HOLLOW LUAN FLUSH DOOR WITH PASSAGE LOCKSET. (2)2"X W
B
2 NEW KITCHEN a D1$ 1 2'4'X B'$' PREHUNG HOLLOW LOAN FLUSH DOOR WITH PRIVACY LOCKSET. (2)2"X 8'
(2)r aTovE
slivuoHr D1-7 1 ONE (1) PAIR 2'-0"X 8'-8" HOLLOW LUAN FLUSH DOORS WITH SLIDING DOOR (2)2"X 8"
ABOVE HARDWARE AND PULLS.
T41! 9
W 1 b r STEP a D1-8 1 2'-0"X 8'-0" PREHUNG HOLLOW LUAN FLUSH DOOR WITH BATHROOM LOCKSET- (2)2"X 8"
EXIST BATH H: SINK W 1 2 132.1 1 2'4"X 8'-0" PREHUNG HOLLOW LUAN FLUSH DOOR WITH PASSAGE LOCKSET.
r-0• (2)2"X 8"
Ir
1 DW a W1-1 1 TWO(2)ANDERSEN NARROLINE DOUBLE HUNG WINDOWS, MODEL NO. 2842, (2)2'X 8'
EXIS.BEDROOM EXIST BEDROOM ® FACTORY JOINED WITH ANDERSEN NARROW MULLION KIT, IN WHITE, WITH
) PERMA-CLEAN INSECT SCREENS IN WHITE.
LAUNDRY b
N REM �� " W1-2 1 ANDERSEN NARROLINE DOUBLE HUNG WINDOW, MODEL NO. 20210, IN WHITE, (2)2"X 8'
Ile
EXISTING ELECTICCIRCUIT r a „F f `� WITH PERMA-CLEAN INSECT SCREEN IN WHITE.
BREAKER T (2)2"X 8"
��
,30' L W13 1 REINSTALL EXISTING TWO (2)WINDOWS AND MULLION AT LOCATION SHOWN.
EXIST HALLWAY CONTRACTOR TO ROTECT- EXISTDEN
CONTRACTOR TO VERIFY ROUGH OPENING REQUIRED.
r
a.1• ,a 9• b CLOSET ( W1.4 1 ANDERSEN NARROLINE DOUBLE HUNG 30 DEGREE ANGLE BAY WINDOW, MODEL (2)2•X 8"
A NO. 30-3442-18, PROVIDED WITH PINE HEAD &SEAT BOARDS AND CABLE
JACUZZI TUB �' ra INBTALLNEwSTRS(OPEN)
2 SUPPORT SYSTEM. WINDOWS IN WHITE WITH PERMA-CLEAN INSECT SCREENS IN
9' fir HI H RISERS(OPEN)®APPROX
77nr HIGH(CONTRACTOR ToVERIFY 1N FIL1D). WHITE.
NEW MASTER BEDROOM NEW HALLWAY OWNER TO SELECT STYLE.HANDRAIL 8
ALIGN W/LANDING BALLUSTERS TO CODE,
NEW BATH f; NG ABOVE W1S 1 TWO (2)ANDERSEN NARROLINE DOUBLE HUNG WINDOWS, MODEL N0. 2442, EXIST HEADER
NEW ENTRY FOYER @ r;. FACTORY JOINED WITH ANDERSEN NARROW MULLION KIT, IN WHITE WITH
LTKY PERMA-CLEAN INSECT SCREEN IN WHITE.
S1-2
—`�`.� � 1 W2-1 1 ANDERSEN AWNING WINDOW, MODEL NO. AW51, IN WHITE, WITH INSECT SCREEN (2)2"X 8'
®
FW-1-74
IN WHITE.
SHOWER EXISTING CONC DECK
0 31-1 2 INSULADOME VENTED SKYLIGHT, 30•X 45"WITH INSULATED SAFETY GLASS, WA
PITCHED ROOF MODEL.
W1� fl B
2 S1-2 1 INSULADOME VENTED SKYLIGHT, 22•X 30"WITH INSULATED SAFETY GLASS, WA
PITCHED ROOF MODEL.
FIRST FLOOR PLAN TYPIDABFELTPANBTRIxT,ON: NOiEC
PROPOSED +ROOF SHINGLES TO MATCH EXISTING
+16 LB PELT PAPF3i 1. CONTRACTOR SHALL VERIFY ALL ROUGH OPENING REQUIREMENTS WITH EACH RESPECTIVE MANUFACTURER
+1/r cox PLvwaoD BHPATHINo 2. ALL DOORS, WINDOWS AND SKYLIGHTS SHALL CONFORM TO THE REQUIREMENTS OF THE NEW YORK STATE ENERGY
+rxe'ROOF RAFTERS Q IW OC CONSERVATION CONSTRUCTION CODE, INCLUDING AIR INFILTRATION RATES OF 0.37 CFM/LIN FT MAX FOR WINDOWS AND
+R-19 FIBERGLASS BATT INSULATION
W/VAPOR BARFUER-INSTALL 0.50 CFM/LIN FT MAX FOR DOORS.
'RAFT-R•MATE'VENT BOARDS 3.ALL DOORS AND WINDOWS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S SPECIFIC
+,rr SHEETROCK-TAPE,SPACK.E&PAINT INSTRUCTIONS AND RECOMMENDATIONS, INCLUDING THE USE OF APPROPRIATE SEALANTS, FLASHINGS,ETC.
SPLICE NEW rxe"RR'BONTO EXIST g
TYPICAL ROOF CONSTRUCTION: r X e'RR'S(MIN SPLICE 34)-)EXTEND 2
+ROOF SHINGLE8 TO MATCH EXI8TMKi 72 TO NEW RIDGE BEAM.CONNECT W/
+15 LB FELT PAPER 4 12A NAILS e'OC,DOUBLE ROW
+,YC COX PLYWOOD SHEATHING RIDGE BEAM-EAD R4 X,4 TYPICAL EXT•WALL CONSTRUCTION:
+r X e•ROOF RAFTERS 7e•OC OP-LAM LVL HEADER RIDGE HT TO +VINYL SIDING AB SELECTED BY ONMER UWDI 8TAIR8 DOWN
+r X FIBERGLASS BATT INSULATION MATCH HIGHEST EXISTING RIDGE +TYVEK HOUSE WRAP
VN VAPOR BARRIEI41N8TALL +,2'COX PLYWOOD SHEATHING 2.X4'TIES a
RAFTR-MATE'VENT BOARDS 72 +r x 4'8TUD8 Q 16'OC 4•-0•GC
+VY SHEETROCK.TAPE,SPACKLE 8 PAINT --17+1- +R-,3 ARRIERA88 BATT INSULATION W/ N
VAPOR BARRIER 2*X1'STUD WALL
+12'SHEETROCKTAPE,SPACKLE&PAINT Q,MOC EXISTING rte'
ATTIC L EXISTING OPEN TO FIRST
ATTIC ARFA7 LOOR BELOW
,a-e'a- >4
W2-1
NEW
NOTE: NEW FINISHED FLOOR ELEV TO BE r HIGHER (2)r X r HDR O
THAN EXIST FINISHED FLOOR ELEVATION FOYY
ER ALIGN WINDOW 2-1 WITH
EXT.WALL CONSTRUCTION: DI EXISTING CENTER OF DOOR 1-4 BELOW
+VINYL 9IDIN0 AS SELECTED BY OWNER CONTINUOUS r X4 KITCH BEDROOM
+TYVEK HOUSE WRAP TYPICAL FLOOR CONSTRUCTION: BOTTOM PLATE(iYP)
+1@'COX PLYWOOD SHEATHING +r X 10'FLOOR J8T8 @ 16'OC B
+r X4 STUDS o 16.00 +R-19 FIBERGLASS BATT INSULATION W/ 2
+R,3 FIBERGLASS BATT INSULATION W/ VAPOR BARRIER
L
VAPOR BARRIER +3µ'PLYWOOD SUBFLOOR (2)r x M CCATREATED
SPACKLE+,/2.SHEETROCK-TAPE, &PAINT .,mp< SELECTED BY TSILL ERMITE SHIELD TO °�� PARTIAL SECOND FLOOR PLA
FLOORING SELECTED BY OWNER TAr DIAX 7LDTO CODE CRAWL SPACE
lZ Rt6iO `nYFoFoAy tu.5XLAn.,3 1/r HO BO LONG
(L2vio14-X1-GP-LAM ANCHOR BOLT(TVP) ExreTs•coNc m
?y N _ BLOCK FM BASEMENT EXI9Te•CONC yrjQOSTING FWEvroR PROPOSED EXTENSION @ O'BRIEN RESIDENCE
BLOCKWALL * �P °�� 350 HICKORY ROAD, SOUTHOLD, NY 11971
MIN r THICK CONCRETE RAT SLAB
* FIRST AND SECOND FLOOR PLANS 81 SECTIONS
DOOR AND WINDOW SCHEDULE
E CT I O N A A
SECTION B B apROu 5494DRAWN BY: RWC DATE: JUNE 2002 SCALE: 1 /4"=1 '-OSFESSIONP
Richard. W. Cuming, P.E.
BellWt, New York 11713 (631) 286-3617 DWG 2 0 F
PROPOSED NEW DORMER INSTALL CONTINUOUS INSTALL CONTINUOUS
RIDGE VENT RIDGE VENT
PROPOSED NEW DORMER
INSTALL NEW ROOF SHINGLES
III Ulu TO MATCH EXISTING INSTALL ALUMUNUM GUTTERS AND
LEADERS AT ALL NEW ROOF EAVES
MATCH EXISTING(TYPICAL)
INSTALL SIDING AS SELECTED
BY OWNF32
1111 11 1111 H 11 11
❑ ❑ OCA � ❑ ❑ ❑
INSTALL SIDING AS SELECTED BY OWNER
T, PROPOSED NEW ADDITION _I t• PROPOSED NEW ADDITION -
WEST ( FRONT) ELEVATION SOUTH ELEVATION
INSTALL CONTINUOUS
PROPOSED NEW DORMER(FRONT) RIDGE VENT
I'll 11 11 Il Y
❑ ❑ ❑ ❑
❑ ❑ ❑ ❑ ELEVATION
ELEVATION
PROPOSED NEW ADDITION
PROPOSED NEW ADDITION f
PtE OF NEW
p0 W. O�
NORTH ELEVATION * P cGZ * PROPOSED EXTENSION OUTHOL , RESIDENCE
EAST ( REAR) ELEVATION PARTIAL NO 350 HICKORY ROAD, TIONS LD, NY 11971
2'"�op5494° e`��� ELEVATIONS
�OEfSS10NP�'
DRAWN BY: RWC DATE: JUNE 2002 SCALE: 1/4"= V-0"
Richard. W. Cumin, P.E.
Bellport, New York 11713 (63 )286-3817 D W G 3 0 F