HomeMy WebLinkAbout28707-Z FORM NO. 3
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
Town Hall
Southold, N.Y.
BUILDING PERMIT
(THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL
COMPLETION OF THE WORK AUTHORIZED/28 ,
PERMIT NO. 28707 Z Date AUGUST 2002
Permission is hereby granted to : \4 0 1
BRIAN K WILLIAMS No's
1425 GABRIELLA CT
for
MATTITUCK,NY 11952
AN ADDITION TO AN EXISTING SINGLE FAMI DWELLING AS APPLIED FOR
at premises located at 142 GABRIELLA CT MATTITUCK
County Tax Map No. 473889 Sec on 108 Block 0004 Lot No. 007 . 035
pursuant to application dat/d AUGUST 12 , 2002 and approved by the
f,A
Building Inspector to ex9ire on FEBRUARY 28 , 2004 .
4`,
Fee $ 324 . 30 .°
Authorized Signature
e,.
d
ORIGINAL
Rev. 5/8/02
FIELD INSPECTION REPORT DATE COMMENTS
o
FOUNDATION(1ST) — J
-------------------------------------
FOUNDATION(2ND) —
z
0
ROUGH FRAMING& "3
PLUMBING -
INSULATION PER N.Y.
STATE ENERGY CODE
FINAL
ADDITIONAL COMMENTS
O
z
m
O
C=J
b
y
CHARLES M.THOMAS
ARCHITECT ,
Ofta At.,208 Lincoln SL
RiWWI MOW, NY 11901
MW":P.O.So 877 Permit Number
Jsmeaport, NY 11947
MECcheck Compliance Report Checked By/Date
New York State Energy Conservation Construction Code
MECcheck Software Version 3.3 Release lc
Data filename: C:\Program Files\Check\MECcheck\PROPOSED ADDITION TO THE WILLIAMS
RESIDENCE.cck
TITLE: PROPOSED ADDITION TO THE WILLIAMS RESIDENCE
COUNTY: Suffolk
STATE:New York
HDD: 5750
CONSTRUCTION TYPE:Detached i or 2 Family
HEATING TYPE:Non-Electric
DATE: 07/24/02
DATE OF PLANS:MAY 2002
COMPLIANCE: Passes
Maximum UA= 143
Your Home=124
13.3%Better Than Code
Grass Glazing
Area or Cavity Cont. or.Door
Perimeter R-Value R-V ue -Factor UA.
Ceiling 1:Flat Ceiling or Scissor Truss 203 19.0 0.0 10
Wall 1: Wood Frame, 16" o.c. 492 13.0 0.0 34
Window 1: Vinyl Frame,Double Pane with Low-E 12 0.340 4
Door 1: Solid 63 0.240 15
Wall 2:Wood Frame, 16" o.c. 492 13.0 0.0 36
Window 2: Vinyl Frame,Double Pane with Low-E 29 0.340 10
Door 2: Solid 21 0.240 5
Floor 1: All-Wood Joist/Truss,Over Unconditioned Space 203 19.0 0.0 10
Boiler 1: , 80 AFUE
COMPLIANCE STATEMENT: The proposed building represented in this document is consistent with the building
plans, specifications,and other calculations submitted with this permit application. The proposed systems have been
designed to meet the New York State Energy 96nservation Construction Code requirements. When a Registered
Design Professional has stamp"d signed t s page,they are attesting that to the best of his/her knowledge,belief,
and professional judg h ans or sp ifications are in compliance with this Code.
Builder/Designer - Date 7
} 't•r'
f
MECcheck Inspection Checklist
New York State Energy Conservation Construction Code
MECcheck Software Version 3.3 Release I
DATE: 07/24/02
TITLE:PROPOSED ADDITION TO THE WILLIAMS RESIDENCE
Bldg.
Dept..
Use
I
Ceilings:
[ ] I 1. Ceiling 1:Flat Ceiling or Scissor Truss,R-19.0 cavity insulation
Comments:
i
I Above-Grade Walls:
[ ] I 1. Wall 1:Wood Frame, 16"o.c.,R-13.0 cavity insulation
Comments:
[ ] ( 2. Wall 2:Wood Frame, 16" o.c.,R-13.0 cavity insulation
I Comments:
I
Windows:
[ ] I 1. Window 1: Vinyl Frame,Double Pane with Low-E,U-factor: 0.340
For windows without labeled U-factors, describe features:
#Panes Frame Type Thermal Break?[ }Yes[ j No
Comments:
[ ] 2. Window 2: Vinyl Frame,Double Pane with Low-E,U-factor: 0.340
{ For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break?[ }Yes[ }No
I Comments:
I
J Doors:
[ ] I 1. Door 1: Solid,U-factor: 0.240
Comments:
[ ] I 2. Door 2: Solid,U-factor: 0.240
Comments:
Floors:
[ ] I 1. Floor 1: All-Wood Joist/Truss,Over Unconditioned Space,R-19:0 cavity insulation
Comments:
I
I Heating and Cooling Equipment:
[ ] I 1. Boiler 1: , 80 AFUE or higher
Make and Model Number
I
Air Leakage:
[ ] I Joints,penetrations, and all other such openings in the building envelope that are sources of air
leakage must be sealed.
[ j I Recessed lights must be 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly
with a 0.5"clearance from combustible materials.If non-IC rated,the fixture must be installed with a
( 3" clearance from insulation.
I
Vapor Retarder:
[ ] I Required on the warm-in-winter side of all non-vented framed ceilings,walls,and floors.
e
�- Materials Identification:
( ) Materials and equipment must be installed in accordance with the manufacturer's installation instructions.
[ j Materials and equipment must be identified so that compliance can be determined.
[ ] Manufacturer manuals for all installed heating and cooling equipment and service water heating
equipment must be provided.
[ ] Insulation R-values and glazing U-factors must be clearly marked on the building plans or specifications.
Duct Insulation:
{ j Supply ducts in unconditioned attics or outside the building must be insulated to R-8.
[ ) Return ducts in unconditioned attics or outside the building must be insulated to R-4.
{ ] ' Supply ducts in unconditioned spaces must be insulated to R-8.
[ j Return ducts in unconditioned spaces(except basements)must be insulated to R-2.
Insulation is not required on return ducts in basements.
Duct Construction:
[ ] I All joints,seams,and connections must be securely fastened with welds,gaskets,mastics
(adhesives),mastic-plus-embedded-fabric,or tapes. Duct tape is not permitted.
Exception: Continuously welded and locking-type longitudinal joints and seams on ducts
operating at less than 2 in. w.g. (500 Pa).
{ ) Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions.
[ } { Cooling ducts with exterior insulation must be covered with a vapor retarder.
{ j Air filters are required in the return air system.
[ ) The HVAC system must provide a means for balancing air and water systems.
1
Temperature Controls:
[ ] Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space
temperature set point of the largest zone.
Electric Systems:
[ ) Separate electric meters are required for each dwelling unit.
Fireplaces:
[ ] Fireplaces must be installed with tight fitting non-combustible fireplace doors.
[ ] Fireplaces must be provided with a source of combustion air,as required by the Fireplace construction
provisions of the Building Code of New York State,the Residential Code of New York State or
the New York City Building Code,as applicable.
Service Water Heating:
L ) I Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the
j water heater has an integral heat trap or is part of a circulating system.
[ ] Insulate circulating hot water pipes to the levels in Table 1.
Circulating Hot Water Systems:
[ ] Insulate circulating hot water pipes to the levels in Table 1.
Swimming Pools:
[ ) All heated swimming pools must have an on/offheater switch and require a cover unless over 20%
of the heating energy is from non-depletable sources. Pool pumps require a time clock.
1
C Heating and Cooling Piping Insulation:
[ ) HVAC piping conveying fluids above 105 OF or chilled fluids below 55 OF must be insulated to the
levels in Table 2.
Mble 1: Minimum Insulation Thickness for G mulcting Hot Water Pipes.
Insulation Thickness in Inches by Pipe Sizes
Heated.Water Non-Circulating, Runout s Circulating Mains and Runouts
Temperature(Fl Up to 1„ Up to 1.25" 1.5"to 2.0" Over 2„
170-180 0.5 1.0 1.5 2.0
140-160 0.5 0.5 1.0 1.5
100-130 0.5 0.5 0.5 1.0
Table 2: Minimum Insulation Thickness for HVAC Pipes.
Fluid Temp. Insulation Thickness in Inches by Pipe Sizes
Pi i System T RanF) 2"Runouts 1"and Less 1.25"to 2" 2.5"to 4"
p Y Yp� Range
Heating Systems
Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0
Low Temperature 120-200 0.5 1.0 1.0 1.5
Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0
Cooling Systems
Chilled Water,Refrigerant, 40-55 0.5 0.5 0.75 1.0
and Brine Below 40 1.0 1.0 1.5 1.5
NOTES TO FIELD(Building Department Use Only)
LT T-1
Applicant/ Dale ;
Owners Name: ' .� �✓e.e _ `, lZevic��ed: / o
Architect/
Engineer:
SCTM ft:
Dislricl: 1,M Secbjon: 13 lock:
project Subdivisio
location: /f-as z > Nance:
Sin} le &, separate Required
call f{�a{ion:
(Yes /Nol 0
Req' Ilcq
�:uning I)islricl� (I,ul)izc u _ �,clual: � (Lon cuvcragc -4 I'rolwsr �p
Rcq 1 I Rcq
s
O ron1':ud —✓-----l' /Req
q
io�`S"d ard �✓ f�+ �
il;car Yard --�3L— I'ro�,osr�rtldv
Project Description:
AGEN�.�.�ERIYiITS
REQUIRED FOR REVIEW N,�l_._ NO . , Perini
Numl
Suffolk County Health-Dept.
New York State D. E. C.
Town Trustees
Town Zomig Board approval: (� _
Town Plarming Board approval:
Flood Plane Elevation??? T
Flood Zone:
• �1 o tes: .
M.Ai
A If A-12
SCDNS REF. # R10 - 97- 0027
266' o-
ovi
SURVEY OF
LOT 11 l
3� •� . '.ro "ELIJAHS LANE ESTATES, SECT. 2
T. •cb yg FLED OCT. 8, 189'8 FX.E NO. 9922
<o - AT MA TTI TUCK
A - � TOWN OF SOU*10LD
® ,Zo. �• = j- o G SUFFOLK COUNTY, N. Y.
9 �J 1000 - 108 - 04 P/O 71
•0
Scale: 1" = 40'
s Dec. 4, 1996
61 Aug 18, OW(r#*)
/9vewwy)
*�` R` 2S
Feb. 2- 1999 (Certification
�O OO,
T o� O.A
so -
• � Jl
V'
CERTIFIED TO,
t V DOROTHYLIAMS WILLIAMS
� .9 0• '�' did AOUEBOGUE ABSTRACT CORP.
J P SUFFOLK COUNTY NATIONAL BANK
2
OF NEW y
AR E4 s.40,00 84 ft. �.`q���i.►,Errs o�.f
o '
.r.,
ANY AL nOU AQOI nVX TO 7W "VEY /S A VKXA TION I am famNar with the STANDARDS FOR APPROVAL The locations o/ wells and cesipoo/s •Is ~�t
Or TSS TX+iE YO W STAT M A��A,� AND CONSTRUCTIO OF SUBSURFACE SEWAGE shown hereon are from /leld observations
Z ALL .
GN ccs S FOR SINGLE FA Y RESIDENCES �• and or /h
from d®te obtained from oers. S LIC. NO. 496/8
Tt+11ER�EtaF Owt r 1F DISPOSAL SYSTEM
SEAL OF rW "VEYOR and wiN abide by the condlllons set forth IhereM and on the P
permit to construct. I3il
A0W�Y._Q CQMWO 1X ' LAW n�> •ALA Y9Y• P. a
By
Or ANO . c , A MAW10 O AN A W061� S T1tA.VELER ST1iE£T
�OUGH -ro D-DAA M*AAt N? N W TW LAW.
H�ULD, M Y. I197f
96 - 317 11
A
M.
Mr,rz?E VENT
12 ASPHALT 5HIN6LE R�QQFINS
12
R10c7c VENT
I"X2" TRIM ON I"X6" RAKE
SHIN&LE ROOFING 2&12& QE IQI& THERMAL MIIN&
I"X45" RAKE FRIEZE SP
IF THE TOTAL MPHAL RAT** 19 ZERO(a OR MIRATER THE
PROPOSW VIESM FOR THE OLLPM ENVELOPE COMPLIES W
T.O._ &-0" PLT. THE ENDW CAXX
5/4"X4" SURROUNDSTHEF04AL TABLE
AREA U-VAUE RATINS Lem
z
A WALL A95EH3LY
EXISTIN& A4. NET WALLSDI +295 6-1
A2. 6LAZW W.W 32 6-4
2446 2446 2446.
A& DOORS 80.00.1 J07 +1 6-1
ILI
----------
SUBTOTAL nt*VL RATM FOR SM11ON A(AJ+A2+A3) 17+1`101
C T1
-ASPHALT SHIN&I.E.Roor_lNe T.Q. 5L_
ONV FLR. IV
B. ROOF/CEILINC7A55EHEILY
-0" IPLT.
T.O. a, IN. ROOFxaLw aft 0* 0
52. 5M1914TS .42 6-3
WOM THERMAL M RATHIS ISECTION 8 651#EW
41060 O.H. DOOR -----.. ___ _
--- x080 O.H. POOR -------
----------
G. FLOOR A55&ftY
2452
EXISTIN& -------- A>* 0
Cl. l"LOOR
2452
f%.........q
62. FOIkIDA"WALL
T.O. FIRST FFLFZ.
WALL PERIMM 0
ABOVE ISRAM EXPORM _..SEI
6RADEiN9U.AT10N DEPTH
aw 7
0 2W B 4V Ut- LU FRONT ELEVATION FOOTIte
SCALE.- 1/4" = 1'-0"
12 REAR ELEVATION
1:2 RIDGE VENT I 5GALE: 1/4" = 1'-0" C3. SLAS EDM 1#11111ATION
ASPHALT 5HIN61-15 ROOFING
SUfFrOrAL T1,119"ok-MTW hoR SWTICN C
TOTAL THEWRATING
(3 LU
Ny,S, E*-Re7y CONSERVATION CQN9TRLJGTQN CODE NOTES - MAR + 110 OK
_CH 1, IqqI
PART 6-1815 EX ILDINS DE516N QX geRtj& RATINQ2
ROW vm
I. ALL WORK SHALL CONFORM TO N.Y.S.ENER6Y COW�k ATION CON5TRI)CTION GOVE
AND SHALL MEET R9 NOT BE LIMITED TO THE'HOLE MINIMUM REOUREMIEV5.
3 C 2. DE516N VALUES: 6,000 DESW "LT E DAYS: \8 Ift7m%25kTHM CfYPJ
2446
2446 2446 3. WINDOW AND DOOR MANLIFACtIREER5 SHALL a�RTIFY THAT THEIR PR(VXT5 MEET Q
MINIMUM U VALLES INDI(ATED AND AIR INKTRATION RATES AS PEP,CODE.
LU
4. Fff;U_�.5HALL BE E61JPPM NTH THE FOLLOHRO:
-VAHzeR NTH AIR LEAKAeE OF 20,�4,F.M. MAXIMIN AT 03 IWAE-5 HATER 6W;-E.
-DA1�C041STION.AIR VENT5,14TH TOTAL CAPACM OF WTkEEN f50 C.F.M.
-�
TO 200 C.F.M.LOCATED IN fEARTH OR AT SIM OF FIRI=30X,DAMPER SHALL 13E
CAPABLEOF 5EW FULLYGL,C�ED.
wraeE twit
5. OIL FRED SERVICE HATER IWATIN6 EXPIffff HMKH PERFORMANCE -EF 6RE-_ATER
THAN N - DOW
EXISTING - MINIKH GOM136TOK EffICOCY OF 10%ARJE (SAS)7A ARJE (OIL)
b. RVAL. EMOMBIT
9KL MEET THE FOLLOWING F5MR;fMaM;
4 D CE VENT DETAIL
-ER
2452 2452 44-VA.C. BWPIENT, PERFORMANCE SHALL BE CBZTM By THE MANLFACTI.F FOR
COfOOV,�XE 14TH-THE KY5,ENERGY CONSERVATION CAME.
------- -THERMOSTAT 50TTIN15 RANGE 450 F To 260 F MV SHALL BE CAPABLE OF SGALE: N.T.5
F BETKEN FILL HEATIN6MV
PROVIDINIS A t)�BNV OF NO LE55 THAN 5
COOLIN16.
1. ALL SERVICE HOT HATER 51JPPLY AND RELIRC&ATION PIPING SHALL BE INSULATED
IN ACCORDANCE WITH THE N.Y,5. ENER6Y CONSERVATION CONSTRUCTION 09M.
b. THESE ORMN66 AND SPECIFICATIONS HAVE BEEN PREPARED 13Y OR ICER THE
DIRECTION OF THE MM 516NED I TO THE HEST OF THE WER516NED I(NORB)61E,
INFORMATION,AND BELIEF,Mff7 THE REGUREMENT5 OF THE N.r.5. ENER6Y CONSERVATION
GON5TRIJCTION CODE (MARCH 1, I"IJ ROOF RWnR
2 SIDE ELEVATION 0 HLIFOtIC.AW CLIP INAILM
SC,ALE: 1/4" 1'-0" 0 TO MWTM 4 PLATE
0
0
OENERAL NOTES U VALUE CALCULATIONS ="x4N TOP PLATM <
I. CONTRACTOR 9iALL ChfCX A44D\,TRFY ALL CONDITIONS TO THE 517E 15. MAINTAIN 2" MINIMUM CLEARANCE BETNEEN ALL 51MTURAL FRAMING T. PLYWOOD DECKING SHALL BE EXTERIOR GRADE PLY
MAINTAIN EV6E5 ROOFICBLD49 0 z (S
PRIOR TO STARTING OF WOW ANID HE SHALL FAMILiARZE HIMS&F WITH HEMR5 AND FIREPLACE OR 0WINEY MASONRY. SOLID BLOCKED OR PLY CHS.
THE WENT OF THESE PI-AM AND MAKE NOW A&RIEE IrM 50,2�e IP0 z
16. ALL FLOOR JOISTS SHALL EM LATERALLY SUPPIORTED BY BRtC)61N6 OR OUTSIDE AIR FILM R rT OUTSIDE AIR FILM R = .rl rh
2. CONTRACTOR OR ORM SHALL OBTAIN A ML01146 PERMIT FROM THE BLOCKING e INTERVALS NOT EXCEEDINS EISHT FE26, ALL 51R1rTURAL STEEL SHALL BE A-3(b STEEL AND SHALL BET. <
TOWN OR VLLA6E PRIM TO STARTIN6 WORK. INSTALLED A6 PER A.I.S.C. ASPRACT ROOF SHNSLES R .44 CMARNINYL (AVEP.A60 R c hq Q1-7. ALL FLAE"NS SHALL BE ALUMINUM.
3. CONTRACTOR SHALL OBTAIN ALJ, BRED APPIWVAL5 PERMITS, 24. ALL DRYKALL SHALL BE use. NAilomAL.&YPsUM CO. 1/2" THICK.
CERTIFICATES OF OCZAPAWY,IN5P�_ TIM APIPROVALS, M.,FOR WORK I&. ALL RAFTERS SHALL BE AW-HORIED TO MA IED HAUS WITH 'HURRICANE TAPED AND SPACKLED THREE COATS. 150 FELT R = D6 TYVEK R = D6
PEFT-ORINMIED FROM ACtNCIIES IWANS JVJW0tGT1CN T+CFX:OF. CLIPS,0 16,ON CENTER. 30, ALL DRYHALL SHALL BE PRII-W AND PA$NTED(2 FINISH GOATS).
.45
4. ALL WORK SWILL CONFORM TO THE NEW YORK STATE UNIFORM FIRE M.ALL IM1EIkIOR DOORS 514ALL BE STAIN GRADE 6'-V FISH X 1-3/6' 31. ALL MOLDW55 AND TRIM SHALL BE 5TAIN4 TRADE AS 5ELE4 TED 13Y
i.
TOW DOORS%1ALL BE P005HE6 AS PER OHNIERL V PLYWOM SHEATHIN19 R 62 10 PLYWOOD SHEAD*NC, R z
PREVENTION AND MALDINIS GORE AND ALL RIA25 AND REGULATIONS OF THE nWX X WIDTH AS NOTED ON PLAN WITH APPROPRIATE.HARDWARE., ALL O68
WNER. Ft
BATT MUSH z ICIDO 3 V BATT IWBULATIM R z 13DO
5. IF -IPITW COURSE OF CVtOPAIICTION A CONDITION E>0WHICHR
5T5 WH 20. 00 NOT SCALE DAHWi11,4196M
N66, TTEM 0 ,SIFIEROEVE SCALM 32. ALL FINISHES M(rERJOP AND EXTERIOR)SWALL MATCH EXISTINO AS "L FACED) (FOL FACED)
0154*691f5 WITH THAT AS WfCAMV ON TWESE PLANS,THE CONTRACTOR DIMENS06. AWAMT RA6 WOT BEEN MAJ�NW CLOSE AS P056BLE.
ON 5M
GYP. ev. WALL Ev. R .43 R .66
5MLL STOP HOW AND NCITIPY THE AFZH"WT. SHOULD HE FAIL TO INSPWT06 AND/OR 09SWATIONS OF THE 35. CAFaVTINC7 SHALL BE SUPPLIED AND IN5TAk-LED BY THE OWNER V IS: \0 GYP, Ev.
FOLLOW TH5 PR0CWURF_ AND C4WINLIE WITH THE +Oac,HE SHALL 21. DRAWINGS MV SPIECrICAYWAS A6 RGIRk"n OF 5ERYICE ARE AND E
ASSUME ALL RE5POWN"LITY NO LIABILITY ARISING TH84T". INNX AIR FLM R = W INSIDE AIR FILM R = .to
AONSTRUCTION SOU SLOPE AWAY BLIENO INTO FOIR*W"TIVY AM POM IS,EW-AnW OR WIT. TJEY AM HOT TO 13E 34. OWNER SHALL SELECT A"COLORS.
*bALL F PRpFERTY OF THE ARCHTIECT 14frOt re PRO.BrT
6. ORADINO AROUND NEW C 0-WIN THE I CT GOWORIKANCE WITH NEH YORK 4M TOTAL R a CAVITY R x 21.40 V D5 WS TOTAL R 0 CAVITY U JO7 r5 HL R R I G A N E GLIF DETA I L
USW ON ANY OINK"WiM75 OR EXT551ONS TO TAPRDJECT EXCEPT 35. ALL PLUMBINS SHALL BE IN 5TRr IS TOTAL R a RAFTER R z 11.46 5% TOTAL R e STW R c135
W A6REI01MEWT IN NRnlWAND KTH ADEWATE C01FDOATION TO THE STATE_WWINe CODE. TW tiN FIXTLIRE:5 I INTO EX15TIN6 SANITARY 01111111% 1
7. ALL fkXrr*jeS SHALL OEM ON UNDISTURBED SOIL WITH A MINIMUM SOL ARC+0TI!GT.. SYSTEM. 5xWAA1ft= SPACE5GALE: N.T.S. IFIMIDE
PRS OF COVER OF 2 TONS PER W FT.AND SHALL HAVE A MIRIMUM OF 3'-0' 22. PATCht A6 fMGLAREP ALL AWAS WERE Exf5TN6W6 MEEN RD40VEP 36. CONTRACTOR SHALL VETERMW HWTHEIR TtE EXISTN& ELECTRICAL ALARM DEVICES
AND/OR NEW WORK Aaft EmnNe Nin E)a5TIN6 MO"AM REMOVEV 5ERACE 19 SUFFICIENT TO SEIZACE,THE NEEK ADDITION AND SHALL IW21DE AR FILM R = h8 &S 10 FAKL 72LI 4_1
h DAYS. OR NEW CIP54W:6 ARE CALLED FOR IN EX15TINS KkIA,PRIOR TO NOTIFY THE OMER AoCCORDWILY. ALL EL EC NOW SHALL BE 130AFV PLUMBING
b. ALL CONCWT SHALL Be 2500 PSI CO%CRETE a 2 REMWAL OF EXISTING HALLS, CEILING W-AME-7, R06F RAFT56, ETC, OF FIRE UNPERWITIR APPROVED, INSTALL,AS PER OWNER'S 1711RECTION ALL PLUMBING WASTE ILts wmom
ANY AW AU WERCAOM, TELEPHONE, AND/WR TV ANTENNA HIRJN& IN \0 PLY14= LWDERLAYMM R a .62
q. DE516N LOAD5, FIRST FLOOR-65#r5F LIVE LOAD CONTRACTOR SHALL_BRACFD%'nN6 AS RIEWRIED t#ML NW W-ADER AS HALLS PRIOR TO INSTALLATION OF WALLMARD� ALL TEHPERATURE dl WATER LINES NEED
ROOF -"/5F-LNE LOAD 5PEC4FW't5 INSTALLED. CONTROL WIRING SHALL RUN GOWEALM I IN POLLS, FL ORS,AND/OR \0 PLYPOW SLOFLOMINS R I 36 TESTING BEFORE COVERING AS NOTM C-
SEC40ND FLOOR -50#/SF LIVE LOAD
CEILING- "?5F -LIVE LOAD 23. CONTRACTOR SHALL P0ZOUTIE AS REWIRED ALL,EXISTING PLUMBIN6, VERIFY OUTLET,SWITCH AND LI4&4TN6 L00AT11ONS WITH
OP#M PRJOR TO INSTALLATION. CERTIFICATION ELJECTRICAL,AIR-CONVITIONINS, AID HEATING LINES Hfthi,INTSUTRE STILL AJR,SPACE R b2 PLUMBER CERT 13.p. -2 9 7d 2
10. VE56H T143M STRESS - DOU6LA5 FIR 500TH,NO.2 GRADE FE) NTH NEW CONSTRUCTION. 377. DOUBLE JOI5T5 UNDER ALL PARTITIONS PANRALLEL TO FRAMING AND ON LEAD CONTENT BEFORE If copper tubing is used
825 PSI,E = I;2OOPW PSI, VENEER LUMBER TOFF DOUGLAS FIR AS PROVIDE DOUBLE HEADER JOISTS AT ALL OPPENIN66. 5 \1 BATT IW5ULATION R z KOO F"MR
24. ALL'1Mt6ROzLAM*LAMINATED CERTIFICATE OF OCCUPANCY for water distributing NOTIFY BUILDING DEPARTMENT AT
II. ALL WAVERS SHALL BE(2) 2"Xbo IN 2'X4' HALL5 11 (3)2*Xb' IN MANUFACTURED BY TRJS J06T C40W.OR E9AL SIZIS AS IVV(ATEP ON 36.THE CONTRACT DOCUMENTS 6ENERALLY WkCATE THE SCOPE AND QUAL (3 X
PLANS. HOZO-LW INSTALLATIONS %IALL BE IN S1?JGT WfOWANCE System; piping shall be 765-1802 9 AM TO 4 PM FOR THE
2•x6'HALLS UNLESS NOTED OTHERWISE, WITH MANUF#�,'TURERS SPECIFICATION5 AM REC4MMIVATIONS. OF THE HORK,MIT ARE NOT PRE5MED AS BEIIIN&FREE FROM ERROIZ5 OR STILL MR.FILM R = hl SOLDER USED IN WATER PROVIOt ANTI-SCALD AN /OR
OMISSIONS,AND MY WORK CALLED FOR IN THIE SWFICATM AND NOT q3%TOTAL R 0 CAVITY R, =22h5 U D15 of typ�,,-,,, !� -1
Q. ALL HEADERS SHALL BEAR ON 4'X4"POST 0 2'X4'HALLS OR 4"Xf)" SUPPLY SYSTEM CANNOT THERMAL SHOCK PREVE LNG i on�l FOLLOWING INSPECTIONS:
25. ALL METAL J015T HAN655 AND OTHER METAL CDWAOR5 WWRIED RHODIN ON TME PRAWN66 AM NOT CALM I=IN TW SPECIFICAT106 15 TO -a TOTAL R a jow R 12.66 1. FOUNDATION - TWO REQUIRE r 0
POST 0 2'Xb* WALLS UNLS6 NOTED OTHERWISE SHALL It 'TECO CONNIECTORS'OR EMAL AND SWU, 1*CAPABLE OF BE PERFORtW AS IF THE NOW HAS CALLED I FOR IN BOTH.AW AND ALL 90 . I
WORK�40 ANY AND ALL MATERIALS NOT LISIEW IN THE BID DOCUMENTS THAT EXCEED 2110 of 1% LEAD. DEVICES AS TO PART. ' (K) UNDER%i,_EP�,� (",01FICATE FOR POURED CONCRETE
-CTIOW POINTS. INSTALLATIONS I'l
51_115 STATION SMOKE IDM-m& ALARM HANDLMS LOADS* CONNE SHALL W- IN fW 12LD I ROUGH - FRAMING & PLUMBING
13. FURNISH AND INSTALL 5146 STRICT' CONIF-01144ANCE HITH MAN�AC.TURERS Ste4nr,#�TIONS,, AND ARE Waffl;W M CAN BE REA50NA&Y OR WOF40LLY BE INTERPWTED OR N.Y. STATE BUILDING C E. INSULATION
MMGE IN COMPLIANCE HITH NEW YORK STATE BULDIW COVE. INFERRM,nIEREFORE,SHALL BE FURNISH AW INSTALLED BY THE
14, ALL NWOH5 SHALL BE WHITE pERM0k_!%4W WITH WeH PERFOFZMANGE CONTRACTOR 4 FINAL - CONSTRUCTION MUST SHT.
GLAZING WAL. INCLUDE 26. DOUBLE JOISTS UNDER ALL PARTITIONS PARALLEL To SAME AND AROUND BE COMPLETE FOR C.O.
_AZIN&AS MANWACn$W By AWep_qN WWOM-L5 OR EL
INSECT SCREENS AND JAMB EXTBVERS A6 REWIRED- ALL OPENINSS. PROVIDE OPENINGS FOR ALL CONSTRUCTION SHALL MEET
PROVIDE % HR. FIRE 00 NOT PROCEED WITH OCCUPANCY OR THE REQUIREMENTS OF THE N.Y.
EMERGENCY ESCAPE AS STATE CONSTRUCTION & ENERGY
REQUIRED BY PART. 714 OF RATED SEPARATION TO FRAMING UNTIL SURVEY USEIS UNLAWFUL CODES. NOT RESPONSIBLE FOR
PART 717.3 M (1) OF of FOUNDATION LOCATION TROUT CERTIFICATI56"at OR CONSTRUCTION ERRORS
N.Y. STATE BUILDING CODE. LOCATIO
Of
WPMCY
N-.Y. STATE BUILDING
CODE. HAS BEEN APPROVED OF 2 ,1
'*-A 4044. vo
r
.. a
t
,
I Of
JTT
„
lAQp Cog�S���S Tye Fo i
7%424-
2-2
I "X12"
_024__
024 $F�.
Memo CONCRETED"
I I I I
„ I1.
POURED CONCRETE FOOTING �3''0� I ` 2"Xia2 .R.�16"oc 2"X "R.R.m b"O I
T
f I I I II { o
1 I I I I I I 1 I \ I I II I
446 INE OF &-0" CEILING
f
- - — — — — — — — — — — — — - -- - - -- - - i
1
EXI5TIN6 FOUNDATION I I UNEXCAVATE
I I
4• AoI � -
u ev
WWI. � 1 EXI5T1NC
o HALL - � � 1 �I I I ( •
1
1 I i5PAKAE
1 I I • I I I I ;_ _ 2"X12_ w�IDc6E
1 I I I I N I I I 11 REMOVE —
PORTION OF - / 2"XI " RIDGE I I I I
EXISTINE7 I
1 I I I I { I I 1 NALL
1 I i
2"XIO" F I I I I I 1
® 16 O
,
` q 7
DROP FOUNDATION HALL DROP FOUNDATION WALL I I 1 2- x12" 2-2"x12'" It I {
TO INVET SLAB TO MEET SLAB 44b /I I I
uj
CONTINUOUS FOOTING CONTINUOUS POOTIN6
IL _ _ _ 2-2"x12 HW, - - --� I '
1 I I ROOF
, 1 I �
1
10
1
12" m TUBE FOOTING
—I MIN. 36 BELOH GRADE .<
1 (MUST BE ON VIR61N 1
J
SOIL) �n
+xi I FOuN�ATION �� � ,� SEGOND FLOOR FLAN
56ALE: 1/4,. _ 1'_O�� i��ED A SCALE: i/4" _ ('-O" a
ASPHALT SHINGLE ROOFN6
1 OVER 15# ROOF FELT ON 1/2" GO X PLYWOOD
1 t� SHEATHING, 2" X b" PROF RAFTERS 0 16" O.G.
TYPIC EI N TI N
I 2" X 8" CEU, JOISTS a IbN O.G.
W/ R BATT. INSULATION
1 2452 2452 2" x b" RAFTER TIES
1 2-2"x12" HDR. 2-2"xl2" HDR. • 32" O.G. r
1X151'1 3,_0„ " q �"°'"
a
1
DECK m � � i/2" GYP.
in T. t 5. 3
TYPICAL FLOOR G N TR GTI TYPIGAL FLOOR GONSTRUGTION
1
ff 4" POURED CONCRETE 0 2"XIO" FLOOR J015TS Ib" O.G. it I/4 TJ FLOOR JOISTS 0 Ib" O.G.
1 PO�ETOH�LENE 1 VAPOR " ATTI
t
BARRIER ON HELL `r
1 COMPACTED POROUS FILL XI N
1 �
1 S
" SECOND FL
+ 8 a TYPICAL- NALL C,,ON5TRUGTION
112„ HD — — 4 POLR1 O
CEDAR PERFECTION 5H1N6LE5 TYVEK HOUSE
3 I/2' STRUGTRUAL STEEL WRAP 1/2" GD X PLYWOOD SHEATHI,N6 ON Z O
GONG SLAB L I/2" .:B FI 2"X4" HD. 5TUD5 0 Ib" O.G. R-15 INSULATION #1J LL1
1 1 — — COLUMN TO FOUNDATION HALL
W 12 X 45 STEEL BE _ _ _7 p w T. t 3 Q
- - - - - ' in 2"X10" FLOOR J015 5 0 16" O.G. Q Q u-
1 3/4" PLYWOOD SU LOOR
1 ' A ` '' W/ MIN. R-la BATT. INSULATION
1 � � � r
REMOVE _
1 PORTION OF O 4'-6"
EX15TIN6
1 ® �( N - FI -W
WALL � 5/8" TYPE "X" 6Y�P. BOARD ON � t _
1 p INTERIOR 6ARA64E HALLS AND Z
EXI5TINC FOYERQ o GEILIN6.
1 I ° 'Ey
1 11 -a
r 3 I/2" STRUGTRUAL STEEL
tt
I 10" FLOOR J015T5� 41 z COLUMN TO FOUNDIATION WALL z " L4I.rL3 b" POURED CONCRETE.FOUNDATION �v
1 " 0 16" OG. r 00 � a cV � HALL ON A 5" X 16" POURED ., - n\
O abr.0 CONCRETE FOOTING �1J
1 CELL i� LIQUID MEMBRANE
2- I " HDR 2 x12" -2" I2" H v
0� DROP FOUNDATION WALL DRZOP FOUNDATION WALL
rQNQ, S AB WATERPROOFING COVE OVER
1 i 1668 68 1668 TO MEET SLAB TO) MEET SLAB FOOTING •--
1 HOR _ „
1 11
1 0� a08o H. DOOR cao8o o.H. DooR _ �
1 1 X�
1 - -2"x12" HDR.
1 - - - - - - - - - I 4 SEGTION �-
I 0 x
11 1 �-- I �•�pa eel nig 2 SCALE: I/4" _ I._O..
5-10 5'-10" _25,10 6 V
rr����yy O 1
ol
I 36 .
i I AUG 2 8 2002
1 2 FIRST FLOOR PLAN
2 5GALE: 1/4" = 1'-0"
OF 2