HomeMy WebLinkAbout29703-Z FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UZ5 , F2003 LL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 29703 Z Date SEPTEMB Permission is hereby granted to : MICHAEL J SCHNEIDER 625 WHITE EAGLE DRIV LAUREL,NY 11948 for ADDITIONS AND ALTERATIONS TO A SINGLE /AMILY DWELLING AS APPLIED FOR at premises located at 5 WHITE EAGLE DR LAUREL County Tax Map No. 473889 S ction 127 Block 0009 Lot No. 025 pursuant to application ted S PTEMBER 2 , 2003 and approved by the Building Inspector to ire on RCH 5, 2005 . Fee $ 681 . 3 V Aut rized Signat ORIGINAL Rev. 5/8/02 f Permit Number REScheck Compliance Certificate Checked By/Date New York State Energy Conservation Construction Code REScheckSoftware Version 3.5 Release lc Data filename:CADocuments and Settings\Mike Macrina\Desktop\Drawings\Architecture East\0305-Schnieder\Energy Calcs\0305-Energy Calc.rck TITLE:Proposed Addition COUNTY:Suffolk STATE:New York HDD: 5750 CONSTRUCTION TYPE:Detached I or 2 Family HEATING TYPE:Non-Electric DATE:08/13/03 DATE OF PLANS:June 16,2003 PROJECT INFORMATION: Mr.&Mrs.Mike Schneider 625 White Eagle Drive Laurel,N.Y. 11948 COMPANY INFORMATION: DA Architecture East �'( p.c. ��5� .SO,yF9y���G'' NOTES: i °• ", The energy calculations are for the proposed addition only. COMPLIANCE:Passes Maximum UA=300 Your Home UA=297 1.0%Better Than Code(UA) Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA Ceiling 1:Flat Ceiling or Scissor Truss 745 30.0 0.0 26 Ceiling 2:Cathedral Ceiling(no attic) 932 19.0 0.0 48 Wall 1:Wood Frame, 16"o.c. 1455 19.0 0.0 72 Window 1:Vinyl Frame:Double Pane with Low-E 221 0.400 88 Door 1:Glass 32 0.400 13 Floor 1:All-Wood Joist/Truss:Over Unconditioned Space 455 19.0 0.0 21 Floor 2:All-Wood Joist/Truss:Over Unconditioned Space 873 30.0 0.0 29 COMPLIANCE STATEMENT: The proposed building represented in this document is consistent with the building plans, specifications,and other calculations submitted with this permit application. The proposed systems have been designed to meet the New York State Energy Conservation Con ucdon Code requirements. When a Registered Design Professional has stamped and signed this page,they are attesting that to tpf his/her knowledge,belief,and professional judgment,such plans or REScheck Inspection Checklist New York State Energy Conservation Construction Code REScheckSoftware Version 3.5 Release lc DATE:08/13/03 TITLE:Proposed Addition Bldg. Dept. Use I Ceilings: ( ] I 1. Ceiling 1:Flat Ceiling or Scissor Truss,R-30.0 cavity insulation Comments: [ ] I 2. Ceiling 2:Cathedral Ceiling(no attic),R-19.0 cavity insulation Comments: I Above-Grade Walls: [ ] I 1. Wall 1:Wood Frame, 16"o.c.,R-19.0 cavity insulation Comments: i Windows: [ ] I 1. Window 1:Vinyl Frame:Double Pane with Low-E,U-factor:0.400 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes[ ]No Comments: I Doors: [ ] I 1. Door 1:Glass,U-factor: 0.400 Comments: I Floors: [ ] I 1. Floor 1:All-Wood Joist/Truss:Over Unconditioned Space,R-19.0 cavity insulation Comments: [ ] I 2. Floor 2:All-Wood Joist/Truss:Over Unconditioned Space,R-30.0 cavity insulation Comments: I Air Leakage: [ ] I Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage must be sealed. [ ] I Recessed lights must be 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly with a 0.5"clearance from combustible materials.If non-IC rated,the fixture must be installed with a 3"clearance from insulation. I Vapor Retarder: [ ] I Required on the warm-in-winter side of all non-vented framed ceilings,walls,and floors. I Materials Identification: [ ] I Materials and equipment must be installed in accordance with the manufacturer's installation instructions. [ ] I Materials and equipment must be identified so that compliance can be determined. [ ] I Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. [ ] I Insulation R-values and glazing U-factors must be clearly marked on the building plans or specifications. I Duct Insulation: [ ] I Supply ducts in unconditioned attics or outside the building must be insulated to R-8. [ ] I Return ducts in unconditioned attics or outside the building must be insulated to R-4. ] I Supply ducts in unconditioned spaces must be insulated to R-8. [ ] I Return ducts in unconditioned spaces(except basements)must be insulated to R-2. Insulation is not required on return ducts in basements. - I Duct Construction: ] I All joints,seams,and connections must be securely fastened with welds,gaskets,mastics (adhesives),mastic-plus-embedded-fabric,or tapes. Duct tape is not permitted. Exception:Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in.w.g.(500 Pa). [ ] I Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions. [ j I Cooling ducts with exterior insulation must be covered with a vapor retarder. [ ] I Air filters are required in the return air system. [ ] I The HVAC system must provide a means for balancing air and water systems. I Temperature Controls: [ ] I Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space temperature set point of the largest zone. I Electric Systems: [ ] ( Separate electric meters are required for each dwelling unit. I Fireplaces: [ ] I Fireplaces must be installed with tight fitting non-combustible fireplace doors. [ ] I Fireplaces must be provided with a source of combustion air,as required by the Fireplace construction provisions of the Building Code of New York State,the Residential Code of New York State or the New York City Building Code,as applicable. I Service Water Heating: [ ] I Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. [ ] I Insulate circulating hot water pipes to the levels in Table 1. I Circulating Hot Water Systems: [ ] I Insulate circulating hot water pipes to the levels in Table 1. I Swimming Pools: [ ] I All heated swimming pools must have an on/off heater switch and require a cover unless over 201/o of the heating energy is from non-depletable sources. Pool pumps require a time clock. I Heating and Cooling Piping Insulation: [ ] I HVAC piping conveying fluids above 105 °F or chilled fluids below 55 OF must be insulated to the levels in Table 2. Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non-Circulating Runouts Circulating Mains and Runouts Temperature(F) Up to 1„ Up to 1.25" 1.5"to 2.0" Over 2" 1 70-180 0.5 1.0 1.5 2.0 40-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range F 2"Runouts I"and Less 1.25'to 2" 2.5"to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water,Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only) TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD,NY 11971 3 sets of Building Plans TEL: (631) 765-1802 Planning Board approval FAX: (631) 765-9502 Survey www. northfork.net/Southold/ PERMIT NO. Oe Check Septic Form N.Y.S.D.E.C. Trustees Examined '20 3 Contact: Approved Of 20 Mail to: Disapproved a/c ? Phone: J(" Expiration �2O � ( � ale _ 13 ---- -------ruil Inspector APPLICATION FOR BUILDING PERMIT iDate 2003 INSTRUCTIONS a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 3 sets of plans, accurate plot plan to scale. Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e. No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting thr property have been enacted in the interim,the Building Inspector may authorize, in writing, the extension of the permit for an addition six months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition er de ' d. he applicant agrees to comply with all applicable laws, ordinances,building code, housing co d r latio , and to t authorized inspectors on premises and in building for necessary inspections. (Si nature of applic or name,if a corporation) (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder ©k .FA - Name of owner of premises (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. Plumbers License No. Eiectricians License No. Other Trade's License No. 1. Location o land on whic proposed work will be done: [,Ad P C L House Number Street Hamlet County Tax Map No. 10�0J0 Section---�-—7i �— Block O Lot og Subdivision P,)e (ilOt.P-� i�,(,�,��t Filed Map No. '-T 1_0 Lot 2 (Name) 2. State existing use and occupancy of pr ices and intended use and occupancy of proposed construction: a. Existing use and occupancy �A ,L---(- �wtil;u,1 tiJ C� b. Intended use and occupancy q14(04- rAt-A 1 t:r CvJ 9 u,l J GI 3. Nature of work(check which applicable): New Building Addition v Alteration Repair Removal Demolition Other Work (Description) 4. Estimated Cost Fee (To be paid on filing this application) 5. If dwelling, number of dwelling units ( Number of dwelling units on each floor If garage, number of cars 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 1 7. Dimensions of existing structures, if any: Front 60 1 Rear O 1 Depth Height Number of Stories 2 1 Dimensions of same structure with alterations or additions: Front 61 .Rear �Z•� Depth LA 112•V5- Height Number of Stories 2 8. Dimensions of entire new construction: Front Rear Depth Height Number of Stories 1 I I 9. Size of lot: Front g Rear 10� •C> Depth •0 10. Date of Purchase Name of Former Owner 1. Zone or use district in which premises are situated f�,-0 O Does proposed construction violate any zoning law, ordinance or regulation? YES NO 'ill lot be re-graded? YES NO Will excess fill be removed from premises? YES NO `T-mes of Owner of premises Address Phone No. me of Architect Agc4v(E -ro r� �i (z, Address .v. ^ Pp 4 f3l q.,tgi4ahone No//2i 12�'� me of Contractor Address Phone No. >this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO YES, SOUTHOLD TOWN TRUSTEES &D.E.C. PERMITS MAY BE REQUIRED. s this property within 300 feet of a tidal wetland? * YES NO YES, D.E.C. PERMITS MAY BE REQUIRED. Ovide survey, to scale, with accurate foundation plan and distances to property lines. elevation at any point on property is at 10 feet or below, must provide topographical data on survey. E OF NEW YORK) SS: LL01a dulysworn, deposes and says that (s)he is the applicant fame of individual signing contract) above named, s the MAat .4y (Contractor, Agent,Corporate Officer, etc.) )wner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; statements contained in this application are true to the best of his knowledge and ef; and t e will be ed in the er set forth in the application filed therewith. >be ore in his of 20 0 Notary Public ignature of A6jlicant ROBERT 1 OTT,JR. Notary Public tate of.New York Qualified Suffolk'County No.Ot SC47250f3� Term Expires May 31, BUILDING PERMTEXAMINERCHECKLIST DATE REVIEWED: -/Z_103 APPLICANT: ,�� �P F I�l� _� DATE SUBMITTED: /,2� /03 SCTM#DISTRICT: 1,000, SECTION: 124 , BLOCK: �_, LOT: 6 SUBDIVISION: ADDRESS: 605 CITY: Lo.t ( ZONING DISTRICT: R&) CONFORMING? BUILDING PERMITS OPEN/EXPIRED: PRE CO: Y OR N BP 2 3660 -Z/C/0 Z- .26635, INFO 3 F-h /BP a5a 33-Z l C/0 Z-424036 , INFO.6 ,z e6c:o BP -Z/C/0 Z- , INFO /BP -Z/C/0 Z- , INFO SINGLE & SEPARATE CERTIFICATION-REQUIRED NOTES: LOTS 40,000SF-100-24,Lot recognition.(CREATED before June 30, 1983),UNDERSIZED LOTS FROM JAN.1997 100-25.Merger.(A nonconforming at anytime after REQ. LOT SIZE: I*k- ACT. LOT SIZE: •wIT REQ. LOT COV. A 7. ACT. LOT COV. REQ. FRONT 0 PROP. FRONT!--:-%�RREQ SIDEo ACT. SIDE REQ. REAR 150 PROP. REAR �/ Q. HEIGHT PROP. HEIGHT PROJECT DESCRIPTION: S,�A-( ESTIMATED PROJECT COST: �i ffDk RCHITEC /ENGINEER: �iryiBlf�V�t.t�N — — WATER FRONT? X0 DESCRIPTION: PA-,TEL #�FLOOD ZONE:y APPROVALS REQUIRED SUFFOLK COUNTY IIEAL'I'H DEPT: YES ol/�ED #): DTE: / _/ PEI-IIT #: _ TOWN SEPTIC RECEIPT: Y 00 NEW YORK STATE DEC: PRE-DEC 9/1/75 YES oro— DTE: / / PERMIT #: SOUTHOLD TOWN TRUSTEES: YES o DTE: / / PERMIT #: TOWN ZONING BOARD APPROVAL: YES or DTE: / / PERMIT #: TOWN PLAN. BOARD APPROVAL: YES o- DTE / / PERMIT #: TOWN HISTORICAL PRE (SPLIA): YE, or N NEW YORK STATE CODF, COMPLIANCE, (SEG PAGE 2): YES or NO NOTES: FEE STRUCTURE: FOUNDATION: SF FIRST FLOOR: L42-1 SF SECOND FLOOR: 1? 00 SF OTHER: SF INIT OTHER TOTAL TOTAL: (,'ZI SF FEE FEE FEE 30 30 1. ( SF)- (��u SF)= l� I SF X $ 30 =$ 31 - +$_ (� +$ _ $ U 1 2. ( —SF)- (— SF)= SFX $ =$ +$ +$ _ $ — 3. (— _—SF)- ( _--SF)= SF X $ —_$-- --+$ +$ _ $--- FINAL _FINAL TOTAL: $ b� 3d NEW YORK STATE CODE COMPLIANCE CHECKLIST CLIMATIC/GEOGRAPHI DESIGN CRITERIA: / Ground Snow Load: 45 Wind Speed: 12OMP Seismic D gn Category: B� Weathering: Severe Frost Depth:36" Ter ' e:M-H Decay: S-M Design Temp: 11 Ice Shield Underlay: YES Flood Hazards: USE/OCCUPANCY CLASSIFICATION: HEIGHT/FIRE AREA: TYPE OF CONSTRUCTION: DESIGN CRITERIA: ENGINEERED/��_LJrC" FULL FRAMING DESIGN ELEMENT HEADERS: Y/N WALL STUDS: Y/N GIRDERS: Y/N CEILING JOISTS: Y/N FLOOR JOISTS: Y/N ROOF RAFTERS: Y/N LUMBER SPECIES AND GRADE: YIN DESIGN LOAD CALCULATIONS LIVE: Y/N DEAD: Y/N SNOW: Y/N SEISMIC: Y/N WIND: Y/N WINDOW AND DOOR SCHEDULE: MISSLE TEST RE UIREMENTS(Y EGRESS .5.7 S.F.. N LIGHT 8%:&/N VENT 40/do/N NAILING/CONSTRUCTION SCHEDULO MEANS OF EGRESDN PLUMBING RISER DIAGRAM-ON LOCATION OF FIRE PROTECTION EQUIPMENT:(!PN TRUSS DESIGN: Y,?9 CERTIFICATION: Y/Io ENERGY CALCS O/N TOTAL COMPLIENCE? Y/N (RETURN TO PAGE ONE) LOT No. 24 N FND, MON. PrR o� DA t L45. �r Z -s-•Z ' N Q *� Lo F � Q N Z tt1 LOT N o. 25 r" { 40012 S.F. eo.�' TT7 % .s � s o r � �p c• 9 00 ti QAw �� 2.0 $ P. NO �T o N � 2.0 30 �V. 1 P wec4. 33.8' • FND, MON. $57• 0.25 F ' LOT No. 26 L r � �o CERTIFIED TO: - M/CH�EG SGH.NE"ipE.4 • • BF?�CXsG'f•%4/ti'pnK/ NAT/O.w�t�. �0 E y WE EXISTOVOE OF RIGHTS OF WAY AND/AR EASEMENTS OF RECORD IF ANY, NOT SHOWN ARE NOT '�% CUARANIFED. tiSFO 6JQ, j IANO UNAUINORIZED ALTERATION OR ADDITION SE�0V 7209 OF THC NEW�xSTATE WOODSIDE 'LANE - EDUCAnaV LAW. COPIES OF THIS SURLEY MAP NOT BEARING THE LAND SURVEYORIS INKED SEAL OR 0/80SW SEAL SMALL NOT BE CONSIDERED TO OE•A.,VALIO MVE COPY. CIIARANIEES INDICATED HEREON SHALL RUN ONLY TO THE PERSON FW WHOM THE SURVEY IS PREPARED, AND QN HIS BEHALF TO THE 71ME COMPANY.GOVERNMENTAL AGENCY AND LENDING INS77YU77ON USTSD HEREON, AND •T.G W ASSYGNEES 41r 7HE LENDINO IIVSn—. • 'W 17ON, GUARANTEES ARE NOT TRANSFERABLEE, SURVEY OF: LOT No. 25 MAP OF GOLDEN VIEW ESTATES KENNI H. BE CK,�t-N • FILED AUGUST 30, 1984 FILE No. 7770 • • 'Surveying ,and Utt}d Planning' SITUATED IN: LAUREL 5018 Expressway Drive South TOWN OF: SOUTHOLD Suite 202 ' Ronkonkoma,, N.Y. 11779E ' SUFFOLK COUNTY, NEW YORK FAX 3fl�.'. 487-2941 aATE:' 5/24/96 JOB, NO. 66—'2460 SCALE: IN Jw 30' DIST. SEC. BLK. LOT S.G:T.M. N0, 1000 127 09 025 /F*YMA& 5Vm /T.,I�/•e' .fey.