Loading...
HomeMy WebLinkAbout28267-Z FORM NO. 4 TOWN OF SOUTHOLD BUILDING DEPARTMENT Office of the Building Inspector Town Hall Southold, N.Y. CERTIFICATE OF OCCUPANCY No: Z-30719 Date: 01/26/05 THIS CERTIFIES that the building ALTERATIONS/ADDITIONS Location of Property: 2170 MAPLE LA GREENPORT (HOUSE NO.) (STREET) (HAMLET) County Tax Map No. 473889 Section 38 Block 8 Lot 1 Subdivision Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated MARCH 28, 2002 pursuant to which Building Permit No. 28267-Z dated APRIL 13, 2002 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is ALTERATIONS AND ADDITIONS, INCLUDING SUNROOM ADDITION, COVERED PORCHES, SECOND FLOOR DECK, AND ROOF OVER DRIVEWAY AREA AS APPLIED FOR PER ZBA #5151 DATED 9/5/2. The certificate is issued to JOSEPH & CAROLYN FERRARA (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL R10-01-0107 12/07/04 ELECTRICAL CERTIFICATE NO. 1130293 07/01/04 PLUMBERS CERTIFICATION DATED 03/06/04 THOMAS AZZARIA i A lrpd Signature Rev. 1/81 FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 28267 Z Date APRIL 13 , 2002 Permission is hereby granted to: JOSEPH & CAROLYN FERRARA 26 SUBURBAN AVE PELHAM MANOR,NY 10803 for ALTERATIONS AND ADDITIONS TO AN EXISTING SINGLE FAMILY DWELLING WITH NONHABITABLE ATTIC AREA at premises located at 2170 MAPLE LA GREENPORT County Tax Map No. 473889 Section 038 Block 0008 Lot No. 001 pursuant to application dated MARCH 28, 2002 and approved by the Building Inspector. Fee $ 6, 298 . 80 Autho ized S gnature ORIGINAL Rev. 2/19/98 FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 28267 Z Date APRIL 13 , 2002 Permission is hereby granted to: JOSEPH & CAROLYN FERRARA 26 SUBURBAN AVE PELHAM MANOR,NY 10803 for ALTERATIONS AND ADDITIONS TO AN EXISTING SINGLE FAMILY DWELLING WITH THIRD STORY AND CERTIFIED SPRINKLER SYSTEM AS APPLIED FOR PER ZBA APPROVAL at premises located at 2170 MAPLE LA GREENPORT County Tax Map No. 473889 Section 038 Block 0008 Lot No. 001 pursuant to application dated MARCH 28, 2002 and approved by the Building Inspector to expire on OCTOBER 13 , 2003 . Fee $ 6, 298 . 80 Authorized Signature ORIGINAL Rev. 5/8/02 .►. Form No.6 • TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines,streets, and unusual natural or topographic features. ,12. Final Approval from Health Dept. of water supply and sewerage-disposal(S-9 form). J3. Approval of electrical installation from Board of Fire Underwriters. ✓4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead. 5. Commercial building, industrial building,multiple residences and similar buildings and installations,a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9, 1957)non-conforming uses,or buildings and"pre-existing"land uses: 1. Accurate survey of property showing all property lines,streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$25.00,Additions to dwelling$25.00,Alterations to dwelling$25.00, Swimming pool$25.00,Accessory building$25.00,Additions to accessory building$25.00,Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential$15.00,Commercial$15.00 Date. New Construction: Old or Pre-existing Building: (check one) Location of Property: i 4 mF �_P-lel✓ G KZ6F.I�PO(ZC' House No. Street Hamlet Owner or Owners of Property: SOS -Ph A �� C-PrQ0l-y tJ FF.V_R�A-�R�F Suffolk County Tax Map No 1000, Section Block 0 6, Lot 0 ( _ Subdivisiony3 A _ Filed Map. Lot: Permit No. Date of Permit. kf Applicant: :SC)5jLNP-W � CA" �E2�P=A-4? Health Dept.Approval: R 10 - (�( 0I CD`Z Underwriters Approval: /J� Planning Board Approval: Request for: Temporary Certificate Final Certificate: ✓ (check one) Fee Submitted: $ r5ao 33o-719 11,1;1 b G ��b� Applicant Signature Q s 5 BY THIS CERTIFICATE OF COMPLIANCE THE S 5 NEW YORK BOARD OF FIRE UNDERWRITERS 5 S 5 S BUREAU OF ELECTRICITY 5 5 40 FULTON STREET — NEW YORK, NY 10038 5 SCERTIFIES THAT S S 5 SUpon the application of upon premises owned by S S S SG&S ELECTRICAL CONTR. JOSEPH FERRARA 5 P.O. BOX 215 2170 MAPLE LANE SSOUTHOLD, NY 11971, GREENPORT, NY 11944 5 Located at 2170 MAPLE LANE GREENPORT, NY 11944 S SApplication Number: 1130293 Certificate Number: 1130293 5 5 5 Section: 38 Block: 08 Lot: 01 Building Permit: 28267 BDC: NS11 5 5 5 Described as a Residential occupancy, wherein the premises electrical system consisting of 5 electrical devices and wiring, described below, located in/on the premises at: 5 S Basement,First Floor,Second Floor,Third Floor,Outside,Attic, S 5 rj A visual inspection of the premises electrical system, limited to electrical devices and wiring to the extent detailed herein, was conducted in accordance with the requirements of the applicable code and/or standard promulgated by the State of New York, Department of State Code Enforcement and Administration, or other 5 authority having jurisdiction, and found to be in compliance therewith on the 1st Day of July,2004. S 5 Name QTY Rate Rating Ci cuit Type 5 5 Cj Alarm and Emergency Equipment Sensor 3 0 Carbon Monoxide Appliances and Accessories SExhaust Fan 3 0 F.H.P. Furnace 1 0 Oil 5 Future Appliance Feeder 2 0 20 amp Amps S Air Conditioner 4 0 36.000 BTU 5 Air Conditioner 1 0 18.000 BTU 5 Wiring and Devices SOutlet 116 0 Fixture S SFixture 116 0 Incandescent SOutlet 195 0 General Purpose 5 Receptacle 112 0 General Purpose 5 Switch 108 0 General Purpose 5 Receptacle 17 0 GFCI 5 Disconnect 5 0 60 amp Air Conditioner SReceptacle 1 0 20 amp Laundry seal Service SContinued on Next Page 1 of 2 SThis certificate may not be altered in any way and is validated only by the presence of a raised seal at the location indicated. S D 5 BY THIS CERTIFICATE OF COMPLIANCE THE 5 5 NEW YORK BOARD OF FIRE UNDERWRITERS S S S S BUREAU OF ELECTRICITY S S40 FULTON STREET - NEW YORK, NY 10038 5 5 CERTIFIES THAT r5j 5 5 5 Upon the application of upon premises owned by 5 5 55 5 r5j G &S ELECTRICAL CONTR. JOSEPH FERRARA 5 P.O. BOX 215 2170 MAPLE LANE 5 SSOUTHOLD, NY 11971, GREENPORT, NY 11944 5 5 5 Located at 2170 MAPLE LANE GREENPORT, NY 11944 5 5 5 5 Application Number: 1130293 Certificate Number: 1130293 5 5 5 5 Section: 38 Block: 08 Lot: 01 Building Permit: 28267 BDC: NS11 5 5 S Described as a Residential occupancy, wherein the premises electrical system consisting of 5 5 electrical devices and wiring, described below, located in/on the premises at: 5 5 Basement,First Floor,Second Floor,Third Floor,Outside,Attic, 5 5 5 Cj A visual inspection of the premises electrical system, limited to electrical devices and wiring to the extent detailed 5 herein, was conducted in accordance with the requirements of the applicable code and/or standard promulgated by the State of New York, Department of State Code Enforcement and Administration, or other 5 authority having jurisdiction, and found to be in compliance therewith on the 1st Day of July,2004. S 5 Name QTY Rate Rating Circuit Type 5 �S] 1 Phase 3W Service Rating 600 Amperes 5 SService Disconnect: 3 200 cb 5 Meters: I 5 5 5 5 S 5 5 S S S S 5 S 5 5 5 5 5S 5 seal 5 � S 2 of 2 S 5 r5U This certificate may not be altered in any way and is validated only by the presence of a raised seal at the location indicated. 5 a APPEALS BOARD MEMBERS Southold Town Hall Gerard R Goehringer,Chairman �� 53095'Main Road Lydia A.Tortora P.O.Box 1179 George Honing ' Southold,New York 11971-0959 Ruth D.Oliva �,�; �!� ZBA Fax(631)765-9064 Vincent Orlando 4l �� Telephone(631)765-1809 http://southoldtown.northfork.net BOARD OF APPEALS TOWN OF SOUTHOLD FINDINGS,DEUBE.RATIONS AND DECISION MEETING OF SEPTEMBER S,2002 Appl.:No.5161-JOSEPH FERRARA. ;Property Location 217A>Meple ane,Greenport; Parcel 38.-8-1: Ttte Zoning.Board of Appeals has visited.the. property under cotts�deration inthis..appircation and.determines that this revlaw(alis under:the Type 11 category;:af'the State'$:List of Actions,without an adverse effect on the environment if the project)s.implernented as planned. PROPERTY FACTSIDESCRIPT.ION The applicant's property is located at the end of Maple Lane The Marcel coi'ter4s of.,3.81.9,acres in size and is improved with'a 2-112 story frame house,unilei renovation. BAB IS.QF APP.UCAT1ON„This application is based on the Building Departments March 13, 20Q2 Ntit[r of psappcokal concerning,alterations to an existing single aMily dwelling in the RR Zone'Dlstrid. FINDINGS OF FACT The Zoning Board ofAppeals,held a,public,hearing Duthie application on.Augu$t 22,2002,at which time: written and oral evidence was presented. Based upon all, testimony, documentation, pe066al ir)spection of the.property,and the area, and other:evidence,,the Zoning Board finds.the'6116wing facts.to be true and relevant. AREA..�(ARI4NCgREIaWTFiF.l1UESTED: Variance under Section 100-62 to allow the existing historic home to be restored;to its original.condition with a third level floor area of 1830+-sq. ft.(ref.March 1;2002'plans'prepared by Archnitechnologies). REASONS F9R1BQARD�ACTION:.Qn the basis of testimony presented,materials submitted, artd person�ll Inspections,th"e Boats makes the following finditags: 9 Gant of the!variapr a wih not or an undesirable cha ge in the neighborhood ore detri.Ment tGl na properflas. This it a historic home.which is in the process of being restoried to.its origin i it bnd tion. 2 benefit squphlyb ;the apphrant cannot be achieved by some method,feasible for the apphgarlt puSSWe„Wer than Relief from the third story] restriction. The proposed restotlation. as'to incjude the existing third floor to maintain the integrity of the historic home: 3. The variance is notsubstantial because itis existing(and has existed for many years). Page 2-September 5,2002"--- Appl.No.6151—Joseph Ferrara �1 ,0 Ap' 58.84 at Greenport 4. The:variance granted will,nod haire.ar►,adverse Effect or trlcipact on the physical or environmental conditions in the neightiiirhoocl gf AlsEnct' No eVir}enCe h is burl Sub i °'" to suggest that this variance will have an adverse impact on the neighborhood. 5. Grant of the requested variance is the minimum action necessary and adequate to.enable. applicant to enjoy the benefit of this historic home while preserving and protecting the character of the neighborhood and the health,safety,and welfare of the community. BOARD RESOLUTION: In considering all of the above factors and.applying the balancing test under New York 71�3wn Law 267-8,motion was offered by Member Oliva,seconded by Chairman Goehringer,'and duly carried,to Q$ANT the variance as applied for and described iiq the March 1. 002.plans Prepared by Architechnolonles for the apalifant,SUBJECT TO THE FOLLOWING CONDITION: That a comprehensive fire sprinkler system be installed on all three floor.levels and be Droperl4 maintained in wood condition at all times. i This action does not authorize or condone any current or future use,,setback or otherfeaturs of the subject.property that may violate the Zoning Code,other than such uses,setbacks and other features as are expressly addressed in this action. Vote of the Board: Ayes:Members Goehringer Tortora,Oliva,and Orlando. This Resolution was duly adopted(4-0). JM. ` ornifig o ash s ) RO proved for Filing-Gerard P.Go nger REC"D AND THE sOI137,-O' V byDA 7 Tom cpax 4�I��UZ 1,OLTR lads i MIR NOTICE OF PUBLIC HEARING SOUTHOLD TOWN BOARD OF APPEALS THURSDAY,AUGUST 22,2002 i NOTICE IS:HEREBY'GIVEN, pursuant to Section 267 of the Town Laws and Chapter 100 (Zoning), Code of, the Town of Southold, the following 'application will be 'heard by the SOUTHOLD TOWN BOARD OF APPEALS at,the Town Hall, 53095 Main Road, Southold, New York 14971;on:THURSDAY.AUGUST 22.,200_?,at the time noted below(or as soon therearfteras may be possible): 7:35,pin Appl. No. 5151 - JOSEPH FERRARA This is a request for a Variance under Section: 1.00-62, based. on the Building Department's March 13, 2002 Notice of bisapproval concerning alterations to an existing single-family dwelling in the.RR Zone . District: The reason the building'permit application was disapproved is that the.Building Department determines the as-built construction does not conform to the code limitation of 2-112 stories. Location of Property: 2170 Maple Lane,Greenport; Parcel 38.-8-1. The:Board of,Appeals will hear all persons, or their representative, desiring to be heard at the hearing,.pr desiring to submit written statements before the conclusion of this.hearing. This hearing will n'ot:start earlier than designated. Files are available for review at the Town Hall (between 8 and 3 p.m.) If you have questions,please do not hesitate to call(631)765-1809. Dated July 23,2002. SOUTHOLD TOWN BOARD OF APPEALS Town Hail 53095 Main Road P.O.Box 1179 Southold,NY 11971-0959 �►Fko��.�, Town Hall,53095 Main Road W Z P.O.Box 1179 Fax(631)765-9502 Southold,New York 11971-0959 y�01 ��� Telephone(631)765-1802 BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATION Date: 3 Building Permit No. (A - Owner: (Please print) Plumber: A z 2 m (Please print) lead. I certify that the solder used in the water supply system contains less than 2/10 of 1% (Plumb s ignature) Sworn to before me this day of n , 20 U ANNIE E.ESGRO Notary Public,State of Ne*York No.01 ES5078083 C(� Qual'died in Suffolk County Commission Expires MaY 19,2007 Notary Public, SU 1,k_ County 1 BUILDING PERMIT EXAMINER CHECK LIST A '6"1V'4e-\ ' DATE I9SUED: /02 _/ DATE REVIEWED: �/:�: /02 APPLICANT: FUMA'P4, C# S DAT&SUBMITTED: 3/x/02 SCTM# DISTRICT: 1,000, SECTION: 3� , BLOCK: � LOT: -I-- STREET ADDRESS: 21-+o lkA-pL6 LAu6 CITY: (�Q ,,ip,�� SUBDIVISION: A/ PROJECT DESCRIPTION: AdQ/HLTCr ESTIMATED PROJECT COST: 47-1-S-V CHITEC ENGINEER: Nornpto FAST TRACK? SINGLE & SEPARATE CERTIFICATION-REQUIRED? Mo NOTES: — LOTS 40,000SF-100-24.Lot recogn i ti on.(CREATED before June 30,1983),UNDERSIZED LOTS FROM JAN.1997 100-25.Merger.(A nonconforming at any time after 7/1/83; ZONING DISTRICT: R-go CONFORMING? gcs REQ. LOT SIZE: 116,*-- ACT. LOT SIZE: '"•"6sREQ. LOT COV. ACT. LOT COV. REQ. FRONT So PROP. FRONT 29S' REQ SIDE LT-jS ACT. SIDE 83'/I&C REQ. REAR so .PROP. REAR Z z s' WATER FRONT? yes DESCRIPTION: -:3.4y PANEL #: /70! FLOOD ZONE: Ai A,L_2w 1wm ,T 1"%Ib- 3cs sU_P-u£y 41Gf x APPROVALS RE IRED SUFFOLK COUNTY HEALTH DEPT: In or NO, (BED DTE: 6 /Zo/ PERMIT#:R10- of - of o TOWN SEPTIC RECEIPT:(RorG) NEW YORK STATE DEC: P"-DEC 9n/75e?'0or NO Ns, MA!j J3,7_ee, SOUTHOLD TOWN TRUSTEES: YES or)M ? Zap TOWN ZONING BOARD APPROVAL: YES or WD TOWN PLAN. BOARD APPROVAL: YES or X0 TOWN HISTORICAL PRE (SPLIA): YES ori NYS ENERGY:<0OR NO Luh sKEiec1 �kccs• "� ��! EGRESS (18 H min.? 4 sq total) VENT(SQ. FT. x 4%) LIGHT(SQ. FT. x 8%) BUILDING PERMITS OPEN/EXPIRED: BP -Z/C/0 Z- , HAVE PRE CO'S : Y OR N BP -Z/C/0 Z- , NOTES: w •A/E�d5 0• (S w ri � or 3 •c„oc� t S' R 2 6� FEE S UCTURE: OUND TION: 2a LGA SF FIRST FLOOR: 19,2-8 SECOND FLOOR: SF 3p- OTHER: SF•-->2136y INIT OTHER TOTAL TOTAL: T SM d y8 FEE FEE FEE g� 1. 10PS SF)- (IM SF)= O -TSF X$ .30 =$2cm4a +$ iso +$# = $,3i yg•yo 'X2 3RD 2. 2-13G SF)- SF)= (I' 5 SF X$ , =$ •_+$/0 +$ _$ 60q.Z° iso s �L �� �3� y ,3� = �t9 GLOIj011. 1� � V t ' z V. r "esi gay Southold�Towrt Hali b tng Qptrkment dui ttn� ilerrf*4 2$267'Z R�:. Pre need t e aoirattion/�temodeii6g tt Existing Forr`ara Res�ddme—. ` East Marian; P1.Y. 5 i. i r' idr r quest cert ttti;:f aunda�o�notice da 1111 y f 4., 2Ca ?3;we i6v� r�r�d �d ar,,�4certyiri tl�rat:ttae eci�ting t�ii'ck-piers Fiav�keen' �iffi on in did # -bey©nd�he'fro�t`lane. If.yt U true any additional sstion please,c©ntact tau o#fice 01 1-�11 9 _ y Th *you for your time and cons�d�eratoti. S�ncerelyj, c=rank Notaro } WRI ;'Caa'�lyn&Joseph serrata ,> - d ' 1 { 4 t r 1 , 07/24/2002 12:57 5162216514 S GIUNTA PAGE 01 FERRARA RESIDENCE Fire Sprinkler Reports for : C,.,,...,...� ;..X,.'I•�''=:•..i r,:;..:..;.."•"'.:'•.''•' ';:: ,t;�?:n,:;v!.ey�y; i`•'.'s'.;t; ;�r��'Siin::;.� .�"?;, it; �.,.. �•,Er•;;,•.!•'•; '',:;:r•,t"'::li.:::::.:::....:: ...::.....,....,. �_:� .;.:7::i.Vii. ::..1...� :: ..... ! Prepared By, Global Fire Solutions APRIL 30,2002 I1 (07/24/2002 12:57 5162216514 S GIUNTA PAGE 02 Elite Sa6iWbi"lopawnt,Inc. FERRARA RESIDENCE Pa"2 ''General Project Data Report !7= X! a q T Project Title: FERRARA RESIDENCE Designed By: Global Fire Solutions Date: APRIL 30, 2002 Code Reference: NFPA 13D Approving Agency: Local Jurisdiction Client Name: Phone-. Address: City, State Zip Code: Company Name: Representative: Company Address; City And State: Phone: Building Name: Building Owner: Contact at Building: Phone at Building: Pip ............. 77777. .2 Description Of Hazard- Light Hazard Sprinkler System Type; WET Design Area Of Water Application: 450 ft' Maximum Area Per Sprinkler: 225 ft2 Default Sprinkler K-Factor. 5,60 K Default Pipe Material: BLAZEMASTER CPVC Inside Hose Stream Allowance, 0.00 gpm Outside Hose Stream Allowance: 0.00 gpm In Rack Sprinkler Allowance: 0.00 gpm Sprinkler Specifications Make: RELIABLE Model, F4/RES Size: 1/2 Temperature Rating: 135 A, TAS Source Of Information: Test Hydrant ID: Date Of Test; 4/30/02 Hydrant Elevation: 0 ft Static Pressure: 66.00 psi Test Flow Rate: 480.00 gpm Test Residual Pressure, 45.00 psi Calculated System Flow Rate: 31.50 gpm Calculated inflow Residual Pressure: 41.49 psi Available Inflow Residual Pressure; 64.87 psi ........... 7777777777�. JU �n Calculation Mode: Demand HIVID Minimum Residual Pressure: 7.00 psi Minimum Desired Flow Density: 0.00 gpm/ft' Number Of Active Nodes: 4 Number Of Active Pipes: 3 Number Of Inactive Pipes: 0 Number Of Active Sprinklers: 2 Number Of Inactive Sprinklers: 0 Active Version 1000 Pipe Capacity Wednesday,July 10,2002 07/24/2002 12:57 5162216514 S GIUNTA PAGE 03 �,..,,.,,,,.,.,.•,,.,w,.,,,"«r'.«,.,.,�,.,.,..,««,.,..�«�.��.,,«.,.. .�,«, .. mmemw�aaoomaaoavx Elft Softwere F : - ERRARA RESIDENCE Pao 8 Fire Sprinkler Input Data lMiCt�f� �.L'�ta• .. .. ... .. ..• ..,:._...:_.... ....' ...,�...,,..�:..:...... ...� ... .... . .. . . . ..............,..... ..__„d:�+�._:���:��'�t_ii_.�....� . Sprinkler Pressure Node Non-Sprinkler Node No. Node Description Area Group KFactor(K) Estimate(psi) Elevation Discharge --...._ (gLm) 10 Non-Sprinkler N/A 41.48 0.00 0.00 20 Non-Sprinkler N/A 40.75 0.00 0.00 30 Sprinkler 5.50 8.88 35.00 0.00 40 Sprinkler 5.60 7.00 35.00 0.00 i i I i i Active Version 1000 Pipe Capselty Wednesday,July 10,2002 07/24/2002 12:57 5162216514 S GIUNTA PAGE 04 1WSoltwraro nt,Inc. FERRARA RESIDENCE Paw 4 ''Fire Sprinkler Input Data .4ple nata-: Nominal Nominal Fitting Total ClFactor Beg- End. Pipe Description Diameter Type Fining Length Length Length (gpm/inch- Nods Nods (inch) Group Data (feet). p—,Q 10 20 TYPE M COPPER TUBE 2.000 0 GC 40.00 18.10 58.10 120 20 30 BLAZEMASTER CPVC 1.000 0 8ET45.00 61.00 106.00 160 .............. 30 40 BLAZEFAASTER CPVC 1.000 0 4ET 15.00 33.00 48.00 150 I i Active Version 1000 Pipe Capacity Wednesday.July 10,2002 07/24/2002 12:57 5162216514 S GIUNTA PAGE 05 Elite Software Developrniant,Inc. FERRARA RESIDENCE -5 Fire Sprinkler Output Data 171Ir*77701. .7 M Pipe Segment Pipe Pipe Sprinkler Flow Non-Sprinkler Flow Beg. Node Imbalance Beg, End. Type Flow Rate At Beg. Node out In Residual Flow At Beg. Node Node...Group ij Pressure(psi) Node Mj gpm) (gp 10 20. 0 0.00 0.00 -0.00- 41.49 20 10 0 -31.49 0.00 0,00 0.00 40.76 -0.00037 20 30• 0 31.49 30 20 0 -31.49 18,68 0.00 0.00 8.88 0.00429 30 40 0 14.82 40 30 0 -14.82 14.82 0.00 0.00 7.00 0.00072 .......... AcW9 Version 1000 P0 Capacity Wednesday,July 10.2002 07/24/2002 12:57 5162216514 S GIUNTA PAGE 06 Ellie Software SM'pMent,Inc, FERRARA RESIDENCE page a ...... ...... ...... 10., It ''Fire Sprinkler Output Data .......... 40 biftut 12 Beg. Nodal Residual Nom. Dia. 0(gprn) F. L./ft Pipe-Lan. PF-(ps!) End. KFactor Elevation Discharge Pressure Inside Dia. velocity (1)"Ift) Fit-Len. PE-(psi) Nods (K) (feet) (gpm) (psi) C-Value 0135) Fittings Tot-Len. PV-(Psi) Type-Gr .............. 10 0,00 0.00 0.00 41.49 ZOO 31.49 0.01274 40.00 0.740 20 0.00 0.00 0.00 40.75 2.009 3.19 GC 18.10 0.000 TYPE M COPPER TUBE 120 0 58.10 0,002 20 0.00 0.00 0.00 40.75 1.00 31.49 0,15769 45.00 16-715 30 5.60 36.00 16.68 8.88 1.101 10.61 8ET 61.00 15.155 BLAZEMASTER CPVC ISO 0 106.00 0.024 30 5.60 35.00 16.68 8.88 1,00 14.82 0,03907 15.00 1.875 40 5.60 35.00 14.82 7.00 1,101 4.99 4ET 33.00 0.000 BLAZEMASTER CPVC 150 0 48.00 0.011 Active Version 1000 P"Capacity Wodneafty,July 10.2002 07/24/2002 12:57 5162216514 S GIUNTA PAGE 07 Elko=;;Development,Inc. FERRARA RESIDENCE P_ -7 Fire Sprinkler Output Data 7. hkf6r -god ....... Flowing Area Group SprinklerSprinkler I Residuaa.Id- 6.ii] Flowing Area Flowing Sprinkler I Sprinkler Elevation Pressure Density Discharge Node No. Code KF*ctor(K) M2) ........ (feet) 30 6.6035,00 8.88 225.00 0.074 16.68 _...._..225.00 0.074!-----16.68 40 5.60 35-00 7.00 225.00 0.066 14.82 Sub Toti&_r6FN­on-dr)6u'p' 225.00 25.00---.0,066 14.82 4.0" Totals For All Groups ------ 450.00 0.066 31.60 A&We Version 1000 Pipe Capadly Wedn"osy,July 10,2002 07/24/2002 12:57 5162216514 S GIUNTA PAGE 08 ........... Elite Saftmrs Development,Inc. FERRARA RESIDENCE 0a Fire Sprinkler Output Summary ft. uft"# Most-'Ckmanding SpIrinkfer Mode" HMD Sprinkler Node Number 40 HMD Actual Residual Pressure: 7.00 pal HMD Actual GPM: 14,82 gpm �7 Sprinkler System Type: WET Specified Area Of Application: 450.00 f? Minimum Desired Density: 0,000 gpmm Application Average Density: 0.070 qpmllf Application Average Area Per Sprinkler 226.00 ft' Sprinkler Flow, 31.50 gpm Average Sprinkler Flow: 16.75 gpm WWAnd filiba"LiMA.7.6W Maximum Flow Velocity(In Pipe 20-30) 10.61 ft/sec Maximum Velocity Pressure(In Pipe 20-30) 0.02 psi Allowable Maximum Nodal Pressure Imbalance: 0,0100 psi Actual Maximum Nodal Pressure Imbalance- 0.0053 psi Actual Average Nodal Pressure Imbalance: 0.0026 psi Actual Maximum Nodal Flow Imbalance: 0.0043 gpm Actual Average Nodal Flow Imbalance- 0.0023 gpm .......... OWN; RQU-A . AA,.,;Z!jd SutnM41". Number Of Unique Pipe Sections: 3 Number Of Flowing Sprinklers: 2 Sprinkler Flow, 31.50 gpm Non-Sprinkler Flow: 0.00 gpm Total System Demand Flow: 31.50 gpm Minimum Required Residual Pressure At System Inflow 41.49 pal Node: Demand Flow At System Inflow Node: 31.50 gpm Active Version 1000 Pipe Capacity WedneWay,July 10,2002 07/24/2002 12:57 5162216514 S GIUNTA PAGE 09 Elko So"re DMIopnient,Inc. FERRARA RESIDENCE P 9 Fire Sprinkler Output Data .......... .......... .. ......... 4, SM -kidew Memand'*Gi.sph"!i.-"":.. 100 - 90 70 so 45 40 30 20 10 ....... 0 1 2 a 4 5 d 7 a 9 10 Flowrate(O 00) gpm i i Adjusted Hydrant Data Static Pressure:55 psi Test Residual Pressure'45 psi Test Flow Rate:480 gpm Demand Point Data Calculated Residual Pressure:41.49 psi I Calculated Flow Rate: 31.49 gpm Excess Available Inflow Residual Pressure:23.38 psi Acbm Version 1000 Pipe Capmdty Wednesday,July 10,2002 New York State Department of Environmental Conservation Division of Environmental Permits Rm 219, Building 40-SUNY AM- Stony Brook,New York 11790-2356 Telephone(631)444-0365 aboo Facsimile (631)444-0360 New Erin Crotty Acting Commissioner LETTER OF NON-JURISDICTION May 8, 2001 Mr. Joseph Ferrara 26 Suburban Ave Pelham Manor, NY 10803 Re: Ferrara property, Maple Lane, East Marion, NY SCTM# 1000-38-08-01 DEC# 1-4738-02879/00001 Dear Mr. Ferrara: Based on the information you have submitted, the New York State Department of Environmental Conservation has determined that: The property landward of the 10' elevation contour as shown on the survey of this property prepared by Joseph Ingegno dated January 9. 2001, is beyond the jurisdiction of Article 25 (Tidal Wetlands). Therefore, in accordance with the current Tidal Wetlands Land Use Regulations (6NYCRR Part 661) no permit is required under the Tidal Wetlands Act . Please be advised, however, that no construction, sedimentation, or disturbance of any kind may take place seaward of the tidal wetlands jurisdictional boundary, as indicated above, without a permit. It is your responsibility to ensure that all necessary precautions are taken to prevent any sedimentation or other alteration or disturbance to the ground surface or vegetation within Tidal Wetlands jurisdiction which may result from your project. Such precautions may include maintaining adequate work area between the tidal wetland jurisdictional boundary and your project (i.e. a 15' to 20'wide construction area) or erecting a temporary fence, barrier, or hay bale berm. Please be further advised that this letter does not relieve you of the responsibility of obtaining any necessary permits or approvals from other agencies. Very ly your , hn Wieland Permit Administrator cc: Architechnologies ITECNOLOGIES 13405 Main hoed,MaUiMck, New Yo&11952 631.298.1129 fax:631.298.1128 March 27, 2002 Southold Town Hall Building Department Southold, NY 11971 Att: Bruno Semon, Mr. & Mrs. Ferrara have provided to me a cost estimate of the value of the existing structure. Upon my own inspection of the property, given the significant value of the architectural features of the existing structure, it is my opinion that the renovation is less than 50%of the replacement cost of the building. (Part 1231.4.) Therefore, it has been our understanding that the structure is applicable with N.Y.S. Codes. Nevertheless, the Building Department has directed the owner,to bring the entire building into compliance with Part 1232. Consequently, certain variances from the State Code may be required: The following code issues have been identified: Height clearance on the main first floor stair leading,up to the second floor. Ceiling height requirements for the existing 3 bathrooms on the third floor. We agree to file the necessary variance application as required by N.Y,S . Law, Mr.&Mrs. Ferrara have also agreed to.do whatever is necessary to comply with all applicable N.Y.S.laws prior to issuance of the.final Certificate of Occupancy a PPlication. , P . u fur time and consideration. r" :in cc: Joseph Ferrara Patricia Moore ITE NOLOGI E S ---- �� ARCf11TEcrURE PLANNM CONS MUMON SMVICBS o7 jj 13405 Main Road,M&WAick, New York11952631.2981129 fmc631.298.1128 MAR 2 14V March 21, 2002 Southold Town Hall Building Department Southold, NY 11971 Re: Proposed Renovation/Remodeling to Existing Ferrara Residence. East Marion, N.Y. ' Regarding our recent building permit application for renovation/remodeling of the existing Ferrara residence located in East Marion, we would like,to state that the entire house will meet or exceed any'necessary egress window required by the State of New York.` Thank you for your time and consideration; Sincerely, Frank Notaro TECNOLQQU, P. 1 W3 lL.l4M*.Nes Yat.11152` 631'RYAN fu:G1."8.1126' October 15;2003 Southold Town Hal ,Building,Department` -Southold, NY 11971 Re:, Proposed,Renovation/Remodeling to Existing Ferrara Residence. East Marion, N.Y. Building Permit # 282672 In response to the inspection done by Mr. ,John Boufis doted October 1Q2003 we request'a 6 (six) month extension to the building permit issued on April`14,2003. The permit expired on October 13, 2003'the extension request,Js till April 2004. If you have any questions,-please'ball the office. Th ,yc ,aour time and consideration, Nfl+rhARr,rnpill �� Lr ��0� cOGy o � CIO Town Hall,53095 Main Road Z 0 Fax(631)765-1823 P.O.Box 1179 Telephone(631)765-1802 Southold,New York 11971-0959 ��! �a� BUILDING DEPARTMENT TOWN OF SOUTHOLD STOP WORK ORDER TO: Joseph & Carolyn Ferrara 26 Suburban Avenue Pelham Manor, NY 10803 YOU ARE HEREBY NOTIFIED TO SUSPEND ALL WORK AT: 2170 Maple Lane, Greenport TAX MAP NUMBER - 1000-38-8-1 Pursuant to Section 45-13 of the Code of the Town of Southold, New York, you are notified to immediately suspend all work and building activities until this order has been rescinded BASIS OF STOP WORK ORDER: construction being done without a Building Permit CONDITIONS UNDER WHICH WORK MAY BE RESUMED: when a Building Permit has been issued Failure to remedy the conditions aforesaid and to comply with the applicable provisions of law may constitute an offense punishable by fine or imprisonment or both. DATED: 2/22/01 Bruno Semon Building Inspector NOLO ]tibllAid. NewY�'i19'�2 i:'7J4�.1139 .Sic 691.24E.11�E March17,201P �USIDC 11RIARVIN CLAD I3LLIMATE R2plum. 1 G EGRESS,WINDQWS: N_OR � , ELEVATI.ON 2ND nOOR; QITANTTTY ID W: oN&H OPN G. 4 CUDH 2424.' 2 CUDH 3224 3'2",x 4'8' ( ) QUa v� oW#QQR— lei .oPN'G. ter,DESMMAROM 4 CUDH,24,22. '2V X 4%,C' t. SOUI .E EVATION 3RD F'LOO.R: Qu SOW# ROvowavn.'DArOiv 2 CUPH2422 '.6,>X 4,49, (E) 4 ' ccm 2836 . #2,'4"X 2'7" ( C) 'BEST UVATLO,N=MOO 1QUAI�ITFTy WmOW# RQUGH OPN'G: �nw.DE.�A'�`�OI�1' 2, CMH 2422 296"X 4'4" E , " �Ey 716N LQQR: g - V4NDOW# RQUGH'OPN'G: WIND, DE9IGNA'I" Q . '2, CCM 2840 TV X 3'39 F' 1hiuBdid.l dt.*WYa& 11932 41I 3%1129 fig 691.M-112a March 27, 2002 Southold Town Hal! Building department - Southold NY" 11971 Att: Bruno Semon, Mr. Mrs. Ferrara have.provided to me a cost estimate of the value of-the " existing structure. Upon myown ins*tion of the property; given tfie si jnificant valueof the architectural features'of the&Acting structure, it is,my opinion that the renovation is less tl h 50%.( f the;rept o nt cost of the building, (Part 1231 A) Therefore;it hes been,our unds,starxflng that:the structure is applicable with .: . ' Nevertheless,the E riding,department has.directed the o%nmer,to ting the entire building:into compk6hoe wh Part 1232. eonseruen�,`certain varxnces' from tha State Code may be required: The following code issues have been identified: Height clearance oh the main first floor,stair leading,up to the second floor. Ceiling height.requiremOM for the existing 3 bathrooms on thethird floor, We agree to file the necessary variance application as required by N.Y.S Law, Mr. &Mrs. Ferrara heva also agreed to do whatever is necessary to'comply'. with all applicable N.Y.S. laws prior to issuance of the final Certificate of Occupancy application. ur time and consideration. e " Cc:;Joseph Ferrara Patda Moore 'G i:'. ... ' TECNOL 2_ }i'i DINw March 21; 2002 - Southold Town Hall Building Department Sour#rcrld;,NY 11911 Re: 1?roposed Renovation/Remodeling to Existing Ferrara Residence, East Marion, N'Y ' Regarding our recent lauilding permit application fcr renovation/rerncielirtg of,the existing Ferrara`residence-located in East Marion,we wr uld Ike to state that;the;entire house will meet or exceed any necessary egress window required by the State of New York. �'Fhank yon for your time and consideration. sinc�rely, _, Frank Wtaro e i a TECKOLOG1: 1J . A. iiD �gl�Z'Ikt1C3�o�ts�Ati►ItaR 1biaAwd.> MWyak.Ih932 7149 lice bpi 29E.1I" March 19, 2002 Southold Town Hall Quilding Department Southold, NY 1.1971 Re: Proposed Renovation/RemoMing to Existing Ferrara Residence. East Marion; N.Y. Regarding our recent building permit application for renovation%remcjdeling of the existing Ferrara resia6rice located`in East Marion,we,would like to state that the entire house Will meet or exceed any necessary energy requirements,of New York State. Thank you for your time and consderatign. Sincerely, Franks Notary 'ECNOLOGIES 0,1,110 . h* ti ' ,i/i "l�in►!Yalt 11962 � � ,� � MAa i s ? Lm-aG.,DEFT. March"�5,2002 ' , r U + Southold Town Hall. Building Department Southold, NY 11971 Re: Roposed�Renovat on/Rernodeling to Existing Ferrara Residence. Eest Marion, N.Y. . Regarding our recent building-perm t application for ren of the existing Ferrara residenci,located,in East Marion, ",would like to request' a phasing of the project. The first request#or a building permit would beto start wQrkon the wrap around porch along with the first and the.second floor of existing structure. (Excluding the third floor) The second request for"a building,permit would involve renovation to the existing,third floor. Thank you for your time and consideration. Sincerely, Frank Notaro i� J . g► i�d��lY� ry to �ai. . mmyc* INS u� Mom* m� ea�s • . p M: R RESIDENCE MARVIN CLAD ULTIMATE DOUBLE HUNG lGRESS:WINDOWS: �E J R 15: NORTH ELEVATION 21'tA'F ,OOIt• e�OF O. DEP QUANTITYm C)W#. RC}UGH QW:P. W +1D DESIGHAON 4 CUDH 2024 27"X 4'8" (F) 2 CUDH 3224 392"X4`891-- (K) NORTH'ELEVATION 3RD FLOOR: , �UATY wlNnow# uGH G., YAM.DEslArroN 4 CtJDH 2020 2'2-X 4'0„ SOiJTH ELLVAT4N 3RD'k'LOOR: QUANTITY WI=W# ROUGH OPN'G; ION 2 CUDH 2020 2'20'.x 4,90„ (E WEST E� !LEVAIATIQRD FLOOit: - - QVIT WINDOW#' ROUGH OPN'G. D ',ION 2 CUDH 2020 2'?"X 4'0" (E) EAST EFLEVATIONIP FLOOR QUANTIT' . WINDOWT# ROUGH OPN'G. WINDS DE$ICiN�4TION 2 CUDH 1620 116"X 0" I1DI,OGLRS =V= 1�1061da�Rad.M�adt,New Ycik 11932 6312961129 d31246.112i March 1, 2002 To Whom It May Concern: Please:be,advised=that l am giving my authorization for the office of Architecnologies; including., Frank,Notaro and Agnieszka Drozdowska, to fill out and file any necessary applications for the state and local agencies for my property located in East Marion, New York; Sincerely yours; Joseph Ferrara, owner New York State Department of Environmental Conservation Division of Environmental Permits Rm 219, Building 40-SUNY Stony Brook, New York 11790-2356 Telephone(631)444-0365 Facsimile (631)444-0360 Erin Crotty Acting Commissioner LETTER OF NON-JURISDICTION May 8, 2001 Mr. Joseph Ferrara 26 Suburban Ave Pelham Manor, NY 10803 Re: Ferrara property, Maple Lane, East Marion, NY SCTM# 1000-38-08-01 DEC# 1-4738-02879/00001 Dear Mr. Ferrara: Based on the information you have submitted, the New York State Department of Environmental Conservation has determined that: The property landward of the 10' elevation contour as shown on the survey of this property prepared by Joseph Ingegno dated January 9. 2001, is beyond the jurisdiction of Article 25 (Tidal Wetlands). Therefore, in accordance with the current Tidal Wetlands Land Use Regulations (6NYCRR Part 661) no permit is required under the Tidal Wetlands Act . Please be advised, however, that no construction, sedimentation, or disturbance of any kind may take place seaward of the tidal wetlands jurisdictional boundary, as indicated above, without a permit. It is your responsibility to ensure that all necessary precautions are taken to prevent any sedimentation or other alteration or disturbance to the ground surface or vegetation within Tidal Wetlands jurisdiction which may result from your project. Such precautions may include maintaining adequate work area between the tidal wetland jurisdictional boundary and your project (i.e. a 15' to 20'wide construction area) or erecting a temporary fence, barrier, or hay bale berm. Please be further advised that this letter does not relieve you of the responsibility of obtaining any necessary permits or approvals from other agencies. Very ly your , hn Wieland Permit Administrator cc: Architechnologies ,A^�S�1P1'1�F.'�t�itB r RiACIIONs�v D4in> 16> d4 NWTA 11452 ' 6312981129 t�631.29.1128 April 21, 2003 Southoid Town Hall Building Department Southold,NY 11971 , Re' Proposed Renovation/Remodeling to Usting Ferrara Residence. East Marion, N.Y. Per,your request, we certify that the construction of the building complies with Type 5-A Construction`and with section` 705-2 of the Building Cotte. The sprinkler system follows type 13D. If you have any additional•questions please contact our office at 631-298-1129. Thank you for your time and consideration: Sincerely, ��*r,��llrtrtre-ryyylyr��,�r �r�tc� 765-1802 BUILDING DEPT. /FOUNDATION NSPECTION [ IST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING [ ] FINAL [ ] FIREPLACE & CHIMNEY REM KS: � /,/i✓1 �� tic Dz ldo .l9LR._. c \ �J DATE 1571A N8PE 9-?IZ167 M-102 BUILDING DEPT. ,,---MSPECTION [ IA90UNDATION IST [ ] ROUGH PLB6. [ j FOUNDATION 2ND [ ] INSULATION [ ] FRAMING [ ] FINAL [ ] FIREPLACE & CHIMNEY RE RKS: ii DATE � P BUILDING DEPT. INSPEC%rl � [ ] FOULs� IST UGH PLBG. [ ] F DATION 2ND [ ] FRAMING [ ] FINAL [ ] FIREPLACE 8 CHIMNEY REMARKS- Vic- DATE INSPECTOR 765-1802 UILDINGDEPT. r INS TIO FOUNDATION • UGH PLBG. • • / INSULATION FRAMING /rl FINAL FIREPLACE & CHIMNEY i I 1 ' - suiLDiNa DE". INSPECTION [ ] FOUNDATION IST ;/�,[_�000N PLBG. DATION 2ND [ J INSULATION FRAMING [ ] FINAL [ ] FIREPLACE 8 CHIMNEY REMARKS:���D�� DATE 8 6 INSPECTO��J����Z 765-1802 BUILDING DEPT. INSPECTION [ ] FOUNDATION IST [ ] �OLB6. [ ] FOUNDATION 2ND [ INSULATION [ ] FRAMING [ ] FINAL [ ] FIREPLACE & CHIMNEY REMARKS: f DATE , -INSPECTOR L 72:- 765-1802 BUILDING DEPT. INSPECTION [ ] FOUNDATION IST [ ] ROUGH PI.BG. [ ] FOUNDATION 2ND [ ] 1 ULATION [ ] FRAMING [ FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION REM RKS:��/�-fD�-✓� DATE � INSPECTOR. a a `�1 FIELD INSPECTION REPORT ATE COMMENTS rm FOUNDATION(1 --- --- ------------------------------------ FOUNDATION(2ND) z ROUGH FRAMING& - -- --------- - - - - t� PLUMBINGy • �I II�An.sl���_` � � ai r INSULATION PER N.Y. STATE ENERGY CODE �l FINAL - l t3 0S �•✓� — --- Ahb ITI -� o o t� � b O tyy� y - �3 iv `Y' vi uvvttiverL UVILJJ11`I`Jrr+1t1Y111 ruZL11.+1'&11V1V Vr1 kLr%- ! BUILDING DEPARTmIe Do you bavo or needowing;before appIr TOFVNHALL Boardofl�aal#1 � �, • S OLTMOLD,NY 11971 3 sits of Buidimg Plzas - 7,6-5-18,02 , �, PERMIT NO. c2 .70 a=k3 • N.'Y.S.D.E.C. � Approved ,20 Mail to: Disapproved a/c .Phone: A//�,�a 3 APPLICATION FOR BUILDING PERMU Date Ilar l — �o .INSTRUCTIONS a. This application.MUST be completely filled in by typcwzitcr or in ink and m*mi tod to the Building Inspector with sets of plans, acct i e-plot plan to Bode.Fee according to w1bdule. b. Plot plan showing location of loot and of busldiags M promises,relationship.to adjoining premises or public streets c areas, and waterways. c. The work covered by this application may not be ca==oed•bcfore issuance of Building Permit. d..Upon approval of this applicatiom,the Building laspc�will issao a Building PC=it to the applicant. S'iich a peim: shall be kept on the premises ava-laNc for iasp=dM&Wjh=the WO& e'.No building shall be oc=pied or used in whole'or in part fbr any purpose Wbat-so-ever until a Ccrt ficate of 0ccupa is issued by the Building Inspwtor, APPLICATION IS HEREBY MADE-to the Bmldhw Dip Wxmt for the issuance of a Building Fmmit pursuant to the Building Zone Ordinance of tha'Town of Southold,Sum Cow�ty,Ncw'Yod;and.othr'applicable Laws, Ordinances or Regulations, for the consWieCM of bufldiags,a4&d0as,•or alterations or for ramoval err demoliticm as herein described. The applicant agrees to comply with all appriicable laws, building code;bming code, , and,to admit authorized inspectors,on premises and in building for n' 'bp , (Sigma of appy or==,if a corporation) p.O ft k 9 k),-1 '0&i7mg addrew of spphca=) State whether applicant is.owner,lessees'agent, architect, azgineer,general contractor, electrician,phunber or.builder .f aek 9T Name of owner of premises �'{� Mme.' �05S--( :FRA'-A (as on the tax roll or-latest deed) If applicant is a corporation, signati of choly w4horized officer (Name and title of corporate offices) Builders License No. Plumbers License No. Electricians License No. Other Trade's License No: 1. Location of land on which proposed work will be done: House Number Street Idaaelct County Tax.Map No'. 1000 Section Block 09 . Loth Subdivision Fi7od Map No. Lot CNS) _2. *Slate existing we aid ooc upwW of pfen lges and we and�O�QMosed 0011SWO1L a. Existimg•use and 000dpincy 1 IUB fFM(�� ' i✓S\n�tl�(�� b. h tende4 use and occupancy 51 hJ.(3-t EE- 1 LL1 3. Nature of work..(check which applicable):New Build' • Addition Alteration Repair Reanoval Demolition Ne Other Work 7_91 t,14 t _ r cription) 4. Estimated Cost (9t I. c� Fbe (to be paid on filing this application) 5. If dwelling, number of dwelling units Number of dwelling writs on each floor If garage, number of cars 6- If business,'commercial or mixed occupancy,specify nature and extent-of each type of use. 7. Dimensions of existing structures,if any:Front . " •6� Rent 1 Depth 2 Height Number of StorieS��%� Dimensions of same structure with ai#eradons or addtdons: Front' 6 Rear 69) Depth 3�' Height 37. Number of Stories o2%, 8. Dimensions of entire new construction:Front _ Rent `� 'J� . Depth 5 Height s •Number of Stodes' 9.. Size of lot: Front *ear 10. Date of Purchase Name of Former Owuuer 11. Zone or use district in•wbich promises are situated —02 12. Does proposed construction violate any zoning law,ordinaace or regulation: K-)C)6, . fl13. Will lot be re-graded_ IV o • Wtil aascesa fill be removed.from psrmises: YES O 14. Names of Owner of Phone No. Name.of Architect - - •_��ArL)VL 0CM�W_o Adm P.0.fox q q) Name of Contractor Address Phone No: 15. Is this property within 100 feet of a tidal wetland? *YES _ NO • IF YES, SOUTHOLD TOWN TRUSTEES PERMITS MAY BE REQUIRED 16. Provide survey, to scale,with accurate foundation plan and distances to.property lines. 17. If elevation at:anyp6inf on propmty is at 10 fed or below;mast provide topographical data on st7rvey. STATE OF NEW YORK) SS: COUNTY OF } ams of indtvi ��,cYf 95��-✓� baing d*gwmn,mases and nyN that(s)he is tbo applicant dual signing contract)above naw (S)Ile is the (Contractor,Asenat,Corporat�OM��tet.c.y� of said owner of owners,aad is dory�to perk=or have p the said work and to mak�c and file this application; that x11,statements oo�ained in this application arc true to the best of his]movi and be �P °Il' performed m the manner'set forth in t$e �° and timet the work tivi1�be alspiication filed thexcwitti. Sworn to before me this .da f 20 Notary Public m�Ylt t�. r, T . SiPatm+e of Applicaiit JOYCE M.WILKINS- NotarV Public.State of New York No.4852246.Suffolk County Term Expires.June 12. 9 0 0 2� ' S -7-o _ M-1802 —�-�• BUILDING DEPT. 3 1 NSPECTION [ ] FOUNDATION IST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ J INSULATION [ ] FRAMING [ ] FINAL [ ] FIREPLACE A CHIMNEY R /4RAW S• Ot �- DATE 2/ oZ INSPECTOR ys f;[G -1`JED ii JT f ? (: sol SURVEY OF PROPERTY �S SITUATED A '1' FAST MANION i TOWN OF SOUTHOLD SUFFOLK COUNTY, NEW YORK S.C. TAX No. 1000 - 38- 08 -01 l SCALE 1 "=30' ° JANUARY 9, 2001 G, FI LWHARY 2, 2001 lOruc RAl'IHCAI `.URVf APHII Y6, 2001 AUIIFD PROPOS I D UI CK W, ' ANIIAWL YbH M MAY )9, 7001 ADD10 APPROX ARIA OF I-XISIINC, Ell PITC SY ,IEM a� J11N1- 10, 2004 UPDATI LUNVI-Y 'oo AUCU',I Zb, 2004 LOCA IID PORTION 01 DRIVI'WAY AS MOVFD OCIOHIl7 Y. 7004 ADW 1) WAIIR IING 0 rLSo AREA = 166,369.41 sq. ft. 1 UT nn TIE INE) 3.819 ac. sOo ooS, Q!"W41111'I1,YJ_ TO coNFJ` o P, COMMONWEALTH LAND 'TITLE INSURANCE COMPANY OF NEW YORK % tS - HOZ PO m a e f - e OWEBSTER BANK IS SUCCESSOR AND/OR ASSIGNS o - JOSEPH FERRARA - G CAROLYN FERRARA FGR 1ICE 2004. - �" �R 1 / r 0 o / ` f�s \9 84 �(n O y y0 �y� Ch OUND I f y CoNc MON P B /ZiGd a I G a i0 r) p 11 P2. sFS F� d 3 0 � z h / '�yG,� VCESSPOOL G 0 UD w , CESSPOOL / I GO we. L- L., 6� O L CESSPOOL- -j ESSPOOL Me N�Aln & H O W O "IE Z a, LU i i --z cF �/ [� OO aD 0'C,N 5- OE "� JI 2 N v L CD e " ;"CC QPNEVIA Qe OOF O (V �- 1 Tg STEPS E,4m {V ^ NCCT0.1p 252' 1 elm GO •.� W W �� es.l• " . RNSE° WWH MEl£ .MOOT o_ FIR. 300 FLR O UNI O O RC1 PU DYER DECK OVEP DECK �' LHIMNEv Z OLS .R - ElSjGR3za Y - 0 0 Ed Z I �. 2-"1 2 HOUSE �oL FRAME Oaf V x O I WOOD p CH ILL r^ GO wppp STEPS co2" "'0 250 / 3 a F' 1 F 02 215CO0 / DECK - � y W _22.E'_ / PS WN�mECN pSOPPA S{EPs � J - 4 ' o. 11LL p WOOD F�jrypI.TON 5,EP5 /- 1 1 00 M I T lT O Z Fqf- I I METAL V.l / COVER -1 06', o s ON O ° O; s 1'626 / 2 FO CO,F - sTORv FPAME ewLpwc oecK N ` \ - `✓`w E - PAno p 5N wDoo STEPS CL E/W \ �OC1PL� if ,G o /oN N 85'06'00" 188.10' '38.25' 81'42'45" OUS 11101 �PH 1fP�/ 1A°a Y DY d i NOTES, u�/- / �`• 1 . FLOOD ZONE INFORMATION TAKEN FROM: / FLOOD INSURANCE RATE MAP No. 36103CO176 G ZONE AE BASE E-1000 LIFVAIIONS DLILRMINED ZONE VE, COASTAL FLOOD WITH VLIOCIIY HAZARD (WAVE ACTION), BASE FLOOD f-1IVAIIONS DEIFRMINF-D ZONE X° AREAS 01 500- YIAk FLOOD', AREAS OF 100-YEAR FLOOD WITH AVERAGE DEPTH OF IESS THAN 1 FOOT OR WITH DRAINAGE AREAS LESS THAN 1 SQUARE MII_I ANTI ARIAS 'ROIECTED BY LEVEES FROM 100 YEAR FLOOD UNAUTHORIZED AIT RAHON oR All TO HIS SURVEY IS A VIUu.00N CI ZONE X AREAS UE ERM NFTJ TO IBI OUISIDF 500-YEAR FLOODPLAIN SECTION 7209 THF THE New YORK SIAT EDUCATION ,AW COPIES 91 THIS SURVEY MAV NOT OCARINL, THE LAND SERVE YORS INKED SGL OR EMBUSSED SEAL SHALL NOT RE CONEIOER11) TO BE A VALID TRUE IOPY CERTIFICATIONS INDICATED HEREON SHAD INN ONLY TO TILE PERSON FOR WHOM THE SLIRVFI IS PREPARED, AND ON HIS BEHALI TO D4 TITLE COMPANY, GOVERNMENTAL AOENOY AND LENDING III ION LISTED HEREON, AND TO THE ASSIGNEES or TI IF LENDING INSD- ILION. CERTIFICATIONS ARE NOT TRANSFER AD[I THE EXISTENCE OF RIGHT OF WAYS AND/OR EASEMENTS OF RECORD, IF ANY, NOT SHOWN ARE NOT GUARANTEED, PREPARI11 IN ACOOROANCE TH THE MINIMUM .STANDARDS FOR TILE SERV SAS ESTABLISHED Joseph A. Ingegno NY FFIE I,A,LS AND ARPR VED AND ADOPTED 1011 SUCH UA TORR RATE LANA DTIC Assoc N °Fq ,. Land Surveyor TIE, S.NI m - SuddW.iC,S - Site PI - COCRINIO/Pn Layout �O `\ 49 PHONE (631)727-2090 ICK (N31)727-1727 ©AN OFFICES LOCATED AT MAILING ADOFCSS N.Y.S LIC No. 49668 322 ROANOKE AVENUE P.O. Box 1931 ---" -- - ---------- RIVERHEAD, New York 11901 R1,erheoU, New YOFk 11901-0966 ----�,_ — -------- 10:,[ 0:if g� TOPOGRAPHICAL SURVEY OF PROPERTY SITUATED AT 1 9 EAST MARION TOWN OF SOUTHOLD SUFFOLK COUNTY, NEW YORK Q a� S.C. TAX No. 1000-38-08-01 SCALE 1 "=30' JANUARY 9, 2001 FEBRUARY 2, 2001 TOPOGRAPHICAL SURVEY APRIL 26, 2001 ADDED PROPOSED DECK & SANITARY SYSTEM MAY 29, 2001 ADDED APPROX. AREA OF EXISTING SEPTIC SYSTEM �s .00AREA ) Co.166,36 sq. ft. Q (TO TIE LINE) 3,$19 OC. 1�4j• � O 'yo 176 Gd CERTIFIED TO: 1 $• `'o ' LS. COMMONWEALTH LAND TITLE INSURANCE COMPANY OF NEW YORK y0� PE EGIFF s ° S WEBSTER BANK IS SUCCESSOR AND/OR ASSIGNS NIEv' 'w• O'' JOSEPH FERRARA CAROLYN FERRARA N0 176 .rw — -- - \ \ 123 104 O .,o/ •/ - \ I // /l// �//'� /// 1 >>W",�9k'o.� \ *r° \\\tet \\ C� /� S'C ! � //"'"� �i(/S� // L1i ill / OIL X61 ,125 o �� TEST HOLE DATA 2y�N (TEST HOLE DUG BY MCDONALO GEOSCIENCE ON JANUARY B. 2001) O��Ya 2 swot Lnw OL BImA'N A, PN£ BiDAN Ox[ TO EowsE swo sw —16 ` � �. b \ \ 55 I I 1 \ ons A 13,e„ E \\ l 15.7 "„ �. IR\\\ \ O O ��T r m, as. .I Ies o N ILLBI VII I o 14 SD 57 G AE TO LwnEE RMa aw NN IN PN£ MOMI o f oo m // // 3 [py�< 17• a ~ y Z I I I l / {/ I I l wit l O 3 QI' U Z DONCAbuML I (�� I�/I I l // /l S`•" ' ' Rt R iwt / ` Gn y�Fye /\ /:1�•O -15 O O Z O _Om N Ail I �rT ' I1. '�t '9.L WFW No _ y / PI'`P H. I W1'P r P eae' _ 2 STORY ' /^ 0HpUSE J h I=- a h / / / 1 I I / . \ �D•' (I"Fp5.�1v17 I /J I / \ //„,5.6 >2� STONE P .15.1 � / 21.6• ' '...os I l l / \\ W v W `° / ^e1T / Dub HOLE C�T Z OFIN�019RE$"P,VG SET � \15.9 — 2. ,15,7 OiS. / E¢ / / I I /�\ \ \ \S \\ OOL � �• A g / 1•Ni s.1 I I I Av � � � + � I V I I I / A A A A Awl .� /' ” t+ �\ „146 - - - - - , _ ���+ sA - - A0. - - - - - - ,Vp�p[•6 �/ \\ \\ \ O \� \ Oi 10 ' O \ \ . .1+55 / / / / / , \ \ .�E �(t- ' // 9 ,. _. E BUILDING \ — —EEO \— -g 1 srom• FwAI - - - - - - - - - veno / { � %mo DECK 4111\\ \\ \\\ \ �\ \ \ ` —• \ — _ _ — •(, ! / /// - - - - - - - - -\ PA01.ice:� -, � •f MOD srtPs \� \\ `\ - - -- ' '<, //// :-' N E ,"Q aIP vEi P /�9 85'06' o .)1.7 __- -- 138.25 70 55 co WOOD DOOR / 61 CD 1 . SNOW COVER ON DATED OF SURVEY. 2. ELEVATIONS ARE REFERENCED TO N.G.V.D. 1929 DATUM OF FIEALTH SERVICES / / EXISTING ELEVATIONS ARE SHOWN THUS:12S SUFFOLK COUNTY DEPARTMENT I / ,� /' ,A:' EXISTING CONTOUR LINES ARE SHOWN THUS: — — — — —Ts- - - - - UL'T'ION FDR'.A N S / // �y� E FL. - BAFIRSE ENT F PEFWTFORAPPROVALOFCONSI'R aFL - BASEMENT FLOOR e GLE AMO.Y RESIDENCE ONLY Aid./ K ' / 3. FLOOD ZONE INFORMATION TAKEN FROM: 117210,27411 C p U/ HS No.. ,U„T / FLOOD INSURANCE RATE MAP No. 3610300176 G APP APPROVED / a ZONE AE: BASE FLOOD ELEVATIONS DETERMINED O ZONE VE: COASTAL FLOOD WITH VELOCITY HAZARD (WAVE ACTION); FOR MAXIMUMOF�BEDROOMS qA BASE FLOOD ELEVATIONS DETERMINED ygA�j1. R&OFAPPROVAL !° bb. ZONE X': AREAS OF 500-YEAR FLOOD; AREAS OF 100-YEAR FLOOD WITH AVERAGE EXPIRES THREE be$'� DEPTH OF LESS THAN 1 FOOT OR WITH DRAINAGE AREAS LESS THAN 1 SQUARE MILE; AND AREAS PROTECTED BY LEVEES FROM 100-YEAR FLOOD. UNIT IORIZED ALTERATON OR AOOMN /fiN se°fP ZONE X: AREAS DETERMINED TO BE OUTSIDE 500-YEAR FLOODPLAIN. SE THIN 1u00E,• Is A vlounoN of VECTION EDUCATION LA . THE NEW YORK STATE °6 r/s/�;, 4. MINIMUM SEPTIC TANK CAPACITIES FOR A 10 BEDROOM HOUSE IS 2,500 GALLONS. COPIESF LAW. COPIES OF THIN SURVEY MAP NOT SWING 1 TANK; 10' di°, 5' LIQUID DEPTH THE LAND SEAL S R'N INKED SEAL SI PROPOSED SEPTIC SYSTEM DETAIL \ 4. MINIMUM LEACHING SYSTEM FOR A 10 BEDROOM HOUSE IS 700 s ft SIDEWALL AREA. EMBOSSED LID SHALL NOT BE CONSIDERED q TO BE A VALID TRUE COPi. .;2 3 POOLS; 10' d1o., 6' DEEP CERTIFICATIONS INDICATED HEREON SHALL RUN (NOT To SCALE) ''.,'/ 1'sr PROPOSED EXPANSION POOL IS ONLY PERSON HIS BEHALFHOM TTO n e� 0, TILE COMPANY, GOVERNMENTAL AGENCY AND HOUOF WP mMFD C FAL.]0,1 4' DEEPme. RHNHm DUDE TENTING INSTITUTION UNTEO HEREON, AND Euv !0]. FINISH �E TO THE ASSIGNEES OF THE LENDING INFER PK BU ED DEEP WL'zg1e EP 21•el. LODNIXD WAIVRI1EHT W INUB I PROOF �, Ise ® PROPOSED LEACHING POOL TUIION. CERRFlCATONN ME NOT TMNSFERIBLE. GVr IKON co.TA TO 6VDE WX. 1'tllo. m•min •mlry MIN. 1' 41a. ,VPKEIeI PIPE TONED D FILE G PROPOSED SEPTIC TANK THE EXISTENCE OF RIGHT OF WAYS Pncnm I/e•/Y 4 FURTHEST LEACHING POOL O AND/OR EASEMENTS OF RECORD, IF '� OF A 3 POOL SYSTEMANY, NOT SHOWN ARE NOT GUARANTEED, a• q 1 ' _ 6. THE EXISTING SANITARY SYSTEM SHALL BE LOCATED AND EITHER FILLED WITH CLEAN I S EI£V vz 1 lEmsz p SAND OR REMOVED PRIOR TO THE INSTALLATION OF THE NEW SANITARY SYSTEM. Rax ' 7 Conm�'XuvTA WLW1 [I+RE PREPARED IN ACCORDANCE WITH THE MINIMUM STANDARDSYHE . GLS A�eD SURVEYS PRPE AAN�OOH o Joseph A. Ingegno FOR SUCH UNE BY THE N YORK STATE LAND 4 TITLE ASSOCIATION Land Surveyor omuNo Arm SEPTIC TANK (11 I, cc 0m[HALL Nwt A MINIMUM CMIPme smmDM OF],CW Fn AT L Mrs. U oy GFC qa 9. WNL THICKIOs 81WL BE A MINIMUM OF]', ATOP 1XpXNFL1 OF E•IND A pr104 THICKNESS 011•. NL wxu, eemu Aro MP Ruu eexwx nFNPOKdxo ro nms,w AFPUM rERCE DF soo RW. LEACHING POOLS (31 yo O ilTle Surveys - SufNfiWslons - Site Plans - Construction LOyOUt e.NL JOINIB MWL Be eFNID ED THAT THE TANK B WANTIM W. I. "HIND MOLD M[10[C CON[IKUmm OF MCGT KENmKCED O]XCKE2(OP EOLLN) T '� 1,THE[p11E LANX•SM,,,[E INIUMLED AT OME1.IN AL1 OIKEOg0.5(WIIX A Mw. roll]IwDE OF At/1� "ANS" eIKUCNKrJ. [DUD OOYUS IND/OK[l.Ns ON A MIxIHUM a NMLL [m OF eCMPt o sw0 En PEA aavEL 2, Al Ea91s [HALL Be or PKmIm RUNMN D wNCKETE(OR EwN). C PHONE (631)727-2090 Fox (631)727-1727 6. AID' .. ..DO [FIKTLI .,I TAM(AND HOUSE [MALL BE YMMNNUD s. A 10' min, OIRNICE NIWQN LEACHING MOO AND WAT[K YNE SHAL eE NNMNNFO AN I, mn. OW", [,II , Uso ME wou ewu.[E MYMNXm. •1 Q MAILING ADDRESS M w W mm. olrtweE EerxTw Na LCAcwxO Faou AND acme rwN ExAu BE u4xrxxm �EO� y OFFICES LOCATED AT N.Y.S. Lic. No, 49668 1380 ROANOKE AVENUE P.O. Box 1931 RIVERHEAD. New York 11901 Riverhead, NEW York 11901-0965 21-103A __ .. - -1�Con">HPa1 u>ek'Y�cR� ly-iC�..�-1'�LI,(1 C.crxS12J� a;-,L i'�c�\(�•Q-� � I' ' -", j - T ` UNDERWRITERS CERTIFICAIE -✓ w. ` =113! � V@OASNOTED �✓ OCCUPANCY OR o TOPOGRAPHICAL SURVEY OF PROPERTY OlUSE IS UNLAWFUL '� aG " WITHOUT CERTIFICATE .�Q SITUATED AT DAT'e'a-� « I.P. EAST MARION � OF OCCUPANCY 0 TOWN OF SOUT14OLD NO I BUILDING DEPA NTA FOO TNS 766.1802 9 AM TO 4 PM i1 U yl SUFFOLK COUNTY, NEW YORK FOL LOWING INSPECTIONS: �4tY� iqP� �� ,, +'• S.C. TAX No. 1000-38-08-01 1, pOIIDVDATION - TWO REQUIRED b SCALE 1":a30' F,c p7URED CONCRETE Q JANUARY 9, 2Q01 2 F;()UrxH • FRAMING & PLUMBING PLUMBER CERTIFICATION o FEBRUARY 2. 2001 TOPOGRAPHICAL SURLY 3. 11i:"ULATION TO �' AREA 165,359.41 .R. n. 4, FINAL CONSTRUCTION MUST ON LEAD CONTENT BEFORE ✓G P.n 3.619 x. eECOMPLETEFORC.O. CERTIFICATE OF OCCUPANCY ALL CONSTRUCTION SHALL MEET `�. THE REQUIREMENTS OF THE N.V. SOLDER USED IN WATER f 1 ' p0 STATE CONSTRUCTION & ENERGY SUPPLY SYS7TEM CANNOT V . E FOR CODESNOT RESPONSIBLE EX cs /{'D rD: DESIGN OR CONSTRUCTION ERRORS 2/10 of I% LEAD. , l ^' •6 ' bi COMMONWGLTH LAND TITLE INSURANCE COMPANY OF NEW YORK U, Q 9. ,AP•,- mss. WE66T6RiEyp NK IS SUCCESSOR AND/OR ASSIGNS - 1Aq `0o, CCAAROLYN FEIRRARA / If copper tubing is used ing P /7`�l E a �� j FI YS\for at NlPinger rshall be �g53 " • R0TOoftyP'=slCorLonlY \ TEST HOLE DATA ,,(D 9 °+ (TEST NO E DUG h ALD �CIENGE ON JAN MPY 9, 2001) _31 OF UNDERWRITERS CERTIFICATE 2Q . STATE UILDIN CODE. 9 N SANDY LOAM OL REQUIRED III, z ` " PROVIDE SMOKE-DETECTING DO OT/R1EEeAN 0 _ ;„ PAIf BROWN FlNE TO COARSE SAND SW FR 41I PROVIDE ANTI-SCALD AND/OR ALARIA DEVICES THERMALSHDCK PREVENTING of e , ' L AS TO PART. 721.1 DEVICES AS TO PART. 902.6(K) N.Y.S BUILDING CODE. HAS DPPR N.Y. STATE BUILDING CODE. ?� WATER IN PALE. KNOWN Q ` ' •' FlNE TO COARSE &AND 5YA crU 1 9 W } p"mflrr OPTNIM FOR 3 Esc S D GS PEA _ �. r.' _CA ELI' I �^ narAs E1, rE 11 1 1. SHOW COM ON DATED OF SURVEY. - \•I';-"1 F:'i P,ART. 71A OF PLUMBING ✓ VJ 2. ELEY ARE DED TO N,O.V.;D. 1920 DATUM Rr t!"ILDING CODE. TCEgMA F SHOrM TNpp ALL PLUMBING WASTE w M THUS, I' 1 `1d'I" �� &WATER LINES NEED + ' mTINI CpNTOUkL ARC SNUW nn .M. TESTING BEFORE COVERING 3. PUMD ZpMF'DI[ORNATION TMg FROM: _ 1 FFF S FI;pOp INSURANCE'RAIE, MAP Ra• moac0176 G r> A� tl/\��R,• �'K ZONE AE BASE FLOCS EFLOLEVATIONSS1pDETREyRARNNEEADq 26NE VE CMBTK FLOpp�TIA�pN3 bLTPiMINED D (*AK ACTIOX): Cr ak w / / ZONE A' NtVS OF SOO-YFAR RODS: ARFA9-OF 100-YEAR For WITH AYE G LASS WARN 1 POST OR WITH DRAINAGE ARfV/S$ LIDS THAN 1 SDUME'I(R4: AND ARPrS RRaTEC7E0 lY LEVIDS FROM 100-YVAR RD00. IL g k �\ H •I EKI5g71ENGN PORCH '2 ZONE K AREAS OVERAWED TO 6E CURVE 500-1FAR FLOOOPWN. T Ri HE REM 4. MINIUM SEPTIC TANK CAPACITIES FOR A 10 BEDROOM,HOUSE IS 21500 GALLONS. w W/XFSPWLAEC 1 TANK: 10'5, S' LIOUIR DEPTH W ,IO FOR A 10 BEDROOM HOMES I5 700 W It 51DIWAU AREA. \�J S MINIUM LFA 1N SYSYEM ql (�- 3 POOLS• 1 /. 5' D[[F ' . 0 N \\yp•'4. PROPOSED LEACHING POOL O Ik PROPOSES,UPMSIOH POOL ff V O ' Ari Y 4. THE,ENISTINO SANIT SYSTEM SHALL BE LOCATED AND EITHER FILLED WITH CLEAN SAND OR REMOVED' ItIOR TO THE INSTILLATION OF THE NEW SANRART SYSTEM. <g�i • QMY h i TO B PORMH t1. „Y RE BE EV'W/iED M 0560 {'m REPFACED'W/' SAME vA';RIY R I MDRwN (ELK) OleI P F . wQ f . i✓ i O +:/ m sN,� �,�4 W R •\ /,,�� N S4 re�rG' -.—• '�SLr. 4P - ❑ 0 CL de y 5 87'42'45" W ItW `Tp,, �•, (SLI NLL- I ¢ a it NW�d� l; b By}�Y R NIR AMAV11®. F Z -41 Gpg ]� 9 yQi'P�� �dA' ryy Cj D qs`?a W Joseph A. Ingegno Land Surveyor AIIeiR(mW1T-mN5 Fu W11Y1T-Im N � t�' I i PROD IRMRA Ai YMM¢A3R�' INOP�3y id� LLE NAME: pl IMYp, M X. 1-031 21-109 FER_91'TE PLAN 8-01.01 - A, MRS W.A0333 : A77WNHNHNEREfA AL ^ 1/4 �1.01. X G I�y£ .. DOG 0 ti SITE I �jfi Ot12 +�0� PLAN OFINV11i� - -v00 ' bWEO. NO.: : ', S - . ' RATION E . I. ENCEA Ear OnA I T ,, v RE THE NPROP OFMTHe AAFFIGH�CTD�,'.. 111 1�© NDiiIRVIRfAN1E.4`I4A�JGEB,.A,NP/DRI MDCNp1214TT` RE.y.■ �r � � AUL � � � � Ei^ ST� � FE �� � � E1P WITo-JOIsr:WA1Rt#N AUTHDRRATIPN Y� W'��L..r BY SHE ITE�1rom IWYREppDD{,1�T'IPNIN PY\RT ' - EWY WHDLY IS STRICTLY PT\DHIPJITEEt EIY LAW. - GENERAL NOTES : CONTRACTOR 'S NOTE : 1 II JilRh :.Hell 1 '1114'1 , IIHII11FH41 :,I -• II /IIJU 11]1 if HI III 11111 1ulIFP FxItiIUA; till )it 1111 1•I1f HI41 Itl H6 HFr11I`/f 11 411_1 F 1HF 4f IIF1It I :. 11 � F •F'11hF til It 411Ill I; LL IN_Il rIU OIVIrA Nf I 111 r]I ❑ J1 '1(l• 1111 1 ' )11111A1 IF 1P .Ifill l 1l_111FI1J.-I if IF I •III HE]I_; H11' If If IF, rA 1 I h Hill I' 1 LEL HE M, Ib F I I .1 1`4I ,[ I ' Ill 1Ill 11111 1 1 _III I1'I If 1 At ?I I III (11lifil F) III';I II1.11II F rIL1 ..I 'HF LH:: I CrNl 111-. • 111 )IJ I ;IH III' ^ FF `, -I I I I rL'P.II ' , I )I "II till H' .1 )N IH41 II H-. UII •I 'r1ti651 IF ,IIu1JI tIJ11111-Lit )vl HCYII _ "f Hl HE IJI M I°LJ I II if I , IIIPAI tI I IR`, SHL I Ill HF I�I 'V)NSIH[ F I UH 41_1_ FI (\II_I l:,IUNS 1FJ11 - rl 1:' IIJ[ 0ILL 111 1 )11 IHI_ ItM I HF �I IC H I I I ( I r It If I AF [At IIIF ItI OF /rll •A H11. 11111JL; H, _ Fill IDd AI IF I ALIL HGII IN:, ,,I I< '"rr I rJh vi, I ii,'I I ' III II I,,F FbF{r-f' N/III HF II l:,I,ll I I I ) I I I IF I ( I[1111 ,( II )II ',II%-1L ll )I"LH I LI I_ 1 ' IH ,=LIIII '1,- ILHI ,I P N19 111 J II 1)VF 111 IItillll Sl l' AII III J(i J I_ ' MSI 111iT?.gllq'., IINI ' II HI HV 9:.1 Fit 11111 F •IL It if IF � IHIr J( �'I I .11 u11(U( )I 1 HILI 11 IF I L141 H,1111pi SF G[ I 141 HE :,I IF ItIIHI F FI I1-11111.1111= 111 rHF•-(:141 . ,11 JII IIFr1: IFJ11IN1 ,' IF )l 11 l II RAI I IF If I +NIIIF IFIICNNI v I9u 1l FI ,I[r11 /-II IIHhIII IIItJ( , I'FE IFP:II-LIIIIfIrlIll lr.1/k(;l- HHF41ill ;1 ,II Ll [1 IIII Nh ;Hh II &J( ! 1x III ?HFI Iq.`.IVH111 IF, / IJII r_IL`,1111 ,4111111 -1-I 1,IH1 )If k , Ir , ell `n'I 'I II 'MtI 1 r ,I 'I1 "111,11 , . .IrILrtJ A , 4r11 J L It lJll6, l l l'' I I < 11 if 11n11114111 III ;,F1A11 - I IIg1 .11 V'L 1!1,1115 III ', Ar-IUI IIL, I '-. ,'I I -11111, 1 ill ! HI-MA.rIIJf-FII I I � I IF IrJ'4HHr' IFII 1, 1111 IF FF 111 llIli', 1II if11,.I I rlrr IIIll 1111 il, 11..II ItIIII., I° -1111111 J111H1 I 1 - - r 5 :• 1 .'v1 IH1 1 ,111'! ! 11 1 , '.iI11H 11 ' i1 $ 1rli Fi^I 11 if 1 I P.:' i ', I I Ilk-)( I , TI AT FA,:,', IF I.',T'F1111 W1 _ - - - - - - - - -- �L J IN RF RD :lL 11_I� FEEL,Jfl `IE%LIFFI FHi1 1 _ R I- '1'{ ^I Ilf11JIHl-11IH ',I =11 ^II If II '_ I IfN IIIF I '-JI rIIFISIIF -111 =IJI ' I', .BILL II L '➢'1 II1',4'n18 HIIU ' I ' Iq 11 � 1U rMI l' HI � IH �1111H' I II '91 HI it IHF P1H dllI_L �� 111141h IJC e 'dL9'J� ; I(Ih 11 F1 )IiAll I . 1' III IIF, SII 1r0 ML tiL 1111 .I It l[ L I I, 1 F It ;dI,LII HI ..I I1_,I It 1, HI UI IF FI I'HUv1 A AI IIi11III 1F I 'H11I ! C1 1 III If IIII I , '.v1111 II fI ' ' 1 I1II WNHI IA /-I HY 11.Yr11-111 Ili III`: Ald rll l'Hu lli 111 1I u1c - ' I H T}il HE [ 1, 1 V,.1 ' ,I .II I FI I;II IN, i HI 11 If )I 11111-I AFI I141 ' .1111JI 'IrIC, A111 I If IF IFI SI .4 I A T 1 JrJ UI r111A' I 11 '1 1I'I IISI III II HI IIJ I 1v11III I .L 11I I 1 i l l 11 111 I I I I I J I I I I I f 11411 H f I A A I I'I I I II , '1R 1II I III IhO HAI III JI , I IV Y1111 1n1I IN HE 4 IF Ii it )II;r'. - I 11 '119 .11, IF L III IFit IliI If!' 111 lit Ff I i I I IF `lFn I I I1F1 1 ./IN1 '-, F11R Z1.'F 1 1 I I I I I ill,11r1 , 1 R.ilq II II lih I 11 1 h d /' 1 I 11 n. '1 11V; JIl l I 1 HI I II I I I t II IjaI 11 ,11 111 IJ It 1111111 r 'lll 1' 111 111111 II ., 111 hI I lIJI I+ ' .I -FI ..11111' ,IY X1 5 �. FII )NI HG," IrI rIF-FI ) IIIF -I 1 Vl 1 �F IIh A111 IIIIFI 1 HF )I V- I aa� I la IF [IIP.( , DIEMOLITI0N NOTES : DE= MOLITION LEGEND : - - -- - - - - 1 1',11111 - U I / 111 I I1 )IJ I HE HI rill I� I-� • T I Ifl 1 )r 1111,11 1111 S1 III 11 1 I tlI' ll„1 , ..11 11a 1H ._r,( 11•• 11111 1 -VIII Ig LIiI-111, 1 -- ( I )111'Ih I I10- 1ItII/)1111' II,J AI JI I HE r I' V'AI I- ,.11 IIIA - 41 , IfIIII cI I111rJ flu L+1` 11J1 � 1 /-H 11111N ' (ILII III J1 1 � Z 0 n1 r 1"I 1111 It 1 f9 FI1 f 1 - yy 111 'I111iI _I' 1-1 L.I III1 I 111 1111 1 •HP P.I I I IIII II II HIF III IL14 1 ,1 I =I ,11111 , - IrJIn1 11 Iif 141-IrI � I LJ W I"I fl Fu 11 FulL , 11„4FHI uR FIF 1,1( 11 1111 it ^fP1 HFfA1 , AI 1 )I I )FLHI IrJ' I111111JI , 4� I pIII' -`A- FF[it-111-111( ItI " IF1IIli M11111 VF 1!, I'ffF 14'11111 Jr I -.I •-.1 . 11 14P1r1 I .1 1141 , a 1, 161111 OF r 1 A 111 ,i�__ - � 11 ,•� W (1) Z I' IIY 11111'II HI' I I I ,I It 1111 I ' I IHI1 I rIll l-11.rlh- I = 111 I'I f IF Il 0111 , 1 . F 1 . 1.. 1111 .•F I � 1 III .' u1111A1 [VISI U•II IIF Le I11•,I All � + 11 � 1r lfpI1111, 11111' 1 1 HIP1' IW lF 1111 .,1 III' 1 � IF 1 II 11 111' f 1 =f IF I I I II:;I I IHH611 p 11 11 1 1 1 hI Hh 1 .IH1 I I r I � VA CONTRACTOR 'S NOTE_ : ------_ _- - �` Q II '1L 141q 1'11. ,11 .111 III 1,11 A. 1rUlllp 4l ' I 1 ! ' flu 1111111111 11 +111111:-,I Ir!11 '1-1-I .,I 1111V 1111 �\ Irl _ - J� TI If -•H1 I i1TL1 T I IF TI IC I d.IF-r,rIT11jr' If 1 I_I-IN, I1 )I I �' N 1101 I'1 141 I I IL UI I I IF I I 116 11 IF 111 if 11 1 1 1 p I 1 1 11 ._,I IF 1, 'L 1 F' 1 [ IF 111111 HI 11J'II / 111111 Ili 11 ',II . 1IIF 11 1 1 11 ' I Ih 111 '.1111 rt- 1111 '1 rItr11111 91 ' 1111 ' 1 LL --I� Z Ifr �1 ✓ /1 ,r111 0 (I F< i I,1 Q r. W o 0 S r 0 n W I .1 1 11 1- . U I , Ill 111 I /I )vF I ., s, L L HE [11 1 IF 'IFI I ' 1111 'I I L - n Ill r1111'I IifI IIlIr1111 - I�1 J TN" d 'hH'r '.-1l IIT 1HI 1 O � ,IIn11 11 IH[ A11111'81,111 ,1 -[IH I'IFv1, 11 T lti I HE 11 1IF )II I_I If 1H H' .1 ❑'I ¢ 1H 1 !F V) r I I I .11 it IFF, ] Cl U N C) I C JJI' CI � 1 L7 ILL ^I O �J 11_111 )JS FXFT 1-'I IHF.I I i I'Ht_I, IFHUH/ HY 'd II'PUHI - - 111 , I UR NFIV r ' If sIRLlc-IfnFf 1� FILE FIAMF 1114 IFI I -1HI-r ',31 I ER IIJEM CUR 2-26-U 1 GENERAL NOTES : CONTRACTOR'S NOTE : u I ALL WORK SHALL COMPLY WITH FEDERAL, STATE, AND LOCAL BUILDING CODES EXISTING SIDING MATERIAL TO BE REMOVED HT1 AND ORDINANCES TO EXPOSE SHEATHING w x .2 BEFORE COMMENCEMENT OF WORK, THE CONTRACTORS SHALL FURNISH THE EXISTING ROOFING MATERIAL TO BE REMOVED ~� z OWNER AND ARCHITECT WITH COPIES OF ALL REQUIRED INSURANCE AND TO EXPOSE SHEATHING AND REMOVE ROOF r 0 WORKER'S COMPENSATION CERTIFICATES AND NAMES OF ALL SUBC014TRACTORS; v WHERE REQUIRED. P"3 THE CONTRACTORS SHALL BE RESPONSIBLE FOR ALL DIMENSIONS AND ,Y a CONDITIONS ON THE JOB THE ARCHITECT MUST BE NOT IFIED OF ANY VARIATIONS FROM THE DIMENSIONS SHOWN j NEW'TYVEK' HOUSE WRAP WILL BE INSTALLED O V; 4 11 IECONTRACTOR SI TALL SUPPLY ALL LABOR AND MATERIAL SI OWN ON TI IE OVER EXISTING SHEATHING U Y _ DRAWINGS NGS UNLESS OTHERWISE NOTED EXISTING SHEATHING (WALL and ROOF) WILL O 3 5 THE CONTRACTOR SHALL BE RESPONSIBLE FOR ADEQUATELY BRACING AND REM41N IF IN GOOD CONDITION AND IF THICKNESS z - PROTECTING ALL WORK DURING MISALIGNMENT AC AGAINST DAMAGE, BREAKAGE, WILL MATCH WITH NEW SHEATHING z a COLLAPSE DISTORTION, AND MISALIC3NMENT 4CCORDING TO ALL APPLICABLE 2 ry CODES ALL EXISTING WINDOWS AND DOORS THAT 6 THE CONTRACTOR SHALL PAY FOR AL PERMITS, FOES. AND COSTS RELATED TO WILL REMAIN NEED TO BE INSPECTED a c THE WORK OF THIS CONTRACT CONTRACTORS SHALL INITIATE ALL REQUIRED INSPECTIONS OF ALL WORK COMPLETED UNDER THIS CONTRACT. WINDOWS AND DOORS THAT PASS INSPECTION - _ = III 1 I I K d THE CON] FACTOR SHALL AT ALL TIMES KEEP THE PREMISES CLEAN AND IS WILL THEN BE RECAULKED AND SEALED PRIOR - - - - 1 1 !I ! 1 HT1 U 24 RESPONSIBLE FOR REMOVAL OF ALL RUBBISH FUR ALL TRADES FROM THE JOB SITE TO INSTALLATION OF NEW SIDING ANY _ D. NY METRAS' FOR ALL OR LEGITIMATE APPROVAL By UNFORESEEN CONDITIONS SHALT BEOWNER AT 'S REQUEST PROVIDE ALTERNATE PRICE , U DOCUMENTED WITH THE T i1I Ii 1 T COS OF APPROVAL BY OWNER OR HIS AGENT PRIOR TO - I I ' TO SHEATHING FOR REMOVAL OF X III o ^ HERE V L ALL EXISTING _ - _ -- -- - I , I STARTING ADDITIONAL WORK _- --- ' 1 ' ' 1 � I SHEATHING AND THE INSTALLATION OF NEW R-1S 9 DOUBLE JOISTS ARE TO BE INSTALLED UNDER ALL WALL PARTITIOIJS RUNNING HIGH DENSITY INSULATION IN REMAINING PARALLEL TO THE FRAMING EXTERIOR PARTITIONS M G PROVIDE DOUBLE HEADER JOISTS AT ALL OPENINGS REFER TO CONSTRUCT DRAWINGS OR F SIZES - _ - - III IIIc 10 ALL FRAMING N ' - - - -- - - I I UMBER TO BE DOUGLAS FIR #2 CONS GRADE OR BETTER 11 I HE CONTRACIOR SHALL PROVIDE SHOP DRAWINGS FOR ALL SPECIAL WORK SUCH AS BUT NOT LIMITED TO 1 I TO. SPRINKLER SYSTEMS AND STEEL WORK l ALI_ SHOP DRAWINGS NEED THE APPROVAL OF THE ARCHITECT - - -- -- - - BEFORE PROCEEDING DEMOLITION NOTES : - - _ DEMOLITION LEGEND : EXISTING PARTITION TO BE REMOVED W Y 1 THE CONTRACTOR SHALL FURNISH ALL LABOR AND IDATERIAL AS REQUIRED TO - -- -- - I ' -- - - _ - COMPLETE THE DEMOLITION AND REMOVAL OF ALL ITEMS AS INDICATED ON THE DEMOLITION PLAN EXIS G PARTITION 1 O REMAIN (S). IIJ } - - - - - _ -_-_ 2 THE CONTRACTOR SHALL EXECUTE THE WORK WITHRJ THE REC ULIJ ATIOS OF i- EXISTING WINDOW TO REMAIN _ I I _ Q w TEMPORARY PROTECTION AS REQUIRED EVERY PRECAUTION SHALL BE TAKEN AS I`xl EXISTING DOOR TO REMAIN ---- - III ; - -- -- - - - - -_- - -- - - -- ' IONBUILDING J TDISU BEXISTNG ELECTRICAL MECHANICAL.AND AND PLUMBING OF DEBRIS INCLUDING IeR EXISTING WINDOW TO BE REMOVED 3 THE COPITRACTOR SI-IALL REMOVE ALL VYALL CONDUITS LEFT AFTER I , (FRl EXIS LING DOOR TO BE REMOVED - - - - -- - - - --- - DEMOLITION AND IF DISTURBED SHOULD BE RE-C IH('UITED - CONTRACTOR'S NOTE : 1111 FX E1 - - - - AFTER THE REMOVAL OF INTERIOR PARTITION^ '1},11111 III IIII ' I 11 1 n11 �11 III (Q THE CONTRACTOR MUST INSPECT AND NOTIP/ IFRI �. is' j III 1 III j l LL THE ARCHITECT OF THE ORIENTATION OF CEILING JOISTS, AT THAT POINT THE ARCHI fECT WILL DETERMINE IF FLUSH HEADERS WILL III 1 1 111 j W NEED TO BE INSTALLED OR IF ANY OTHER III III ILL TYPE OF ST"RUCTURAL MEMBER WII NEED ON - (Fa) -I -1 TC BE LISEL -' - - - - --- - - - — - ,`•-1� I 'I1 � � ItH, I - _0 I - - W - 1 ER .I I J Ea - 1 i r Z I _ I W _ 1 III � I II1 EII I I I ( V/ III EH EIR Q 1 � -- - - , SII - FR Z I I 0 I III ! 1I II T 'I II a 0 — (n Ir ER ER 'ER I LL I ( ( I W I II I II W 1 I, I D — tH I i'I I I III III ' I I , � III I ( II 11 : 1W I II1II III fi > ' FR !FR I ' III I // U W �i III IIII 11111 IT FIR r W 1 I j 1I 0 I . a REMOVE l HIS SECTION OF I ¢ H HE X T _ � MO 't EMS PUNCT I 0 a I sT I :TDR AND P I ''. H JC E N . PROVIDE L AND ROOF IL W LEMPORARY SUPPORT .I - � II ', 'I ' 1 � i � ❑ T t Ii III � i PRO\ TEPORARr S 1R4 � � L UHl Z. I 0 I ' FOR NEW CONSTRUCTION � W 1. O TF'F ALL AREAS) - U O T I 0 0 ILII III � ' 11 '' F V- W W 7 7 D o n FILE A I' N ME - - - - --- -- - - �i _- _ - FER I i I1 2DEM CUR 1111 I 1'l_-2Fi-01 I w w +W ly � N SCALE Fd. 4 ♦ � X h1 H �a � r r �Y - � � i4r— ylorl r a w F DWG NAME SECOND FL. a�� 4�21 �E o 1111 DEMOLITION ,11,ens� PLAN DWG NO THESF C VIAV.V IGS AS INSTRUMFPITS VF SEW'IGF ARF THF SOI F PROPERTY OF THF ARCHITECT NO RP/ISIONS CHANGES AND OR MODIFICATIONS r SHAI I BF Al LOV/FD WITHOUT WRITTEN AUTHORVAIIOII 9 A. D E M O Y IHEARCHITECI ANY HEPROLIUCIIOH 1NA PHI OH NHOI F IS S,RIC 1 r Y PROHIHR FD HY I.lVr GENERAL NOTES : CONSTRUCTION LEGEND : INSULATION NOTES : DOOR LEGEND : ELECTRICAL LEGEND : v1 1, ALL WORK SHALL COMPLY WITH FEDERAL, STATE, AND LOCAL BUILDING CODES EXISTING EXTERIOR PARTITION TO REMAIN. PROV 1/2" GYP. SD. & R-15 HIGH AND ORDINANCES EXISTING EXTERIOR WALLS. 2"X4" WOOD STUD. R-15 HIGH DENSITY INSULATION r7l ,5 DENSITY INSULATION TO ALL EXISTING EXTERIOR WALLS BV'CERTANTIEED' OR APPROVAL EQUAL NOTE ALL INTERIOR CASING TO BE STANDARD COLONIAL CASING CLEAR PINE NOTE. ALL ELECTRICAL WORK TO BE IN ACCORDANCE WITH THE RULES AND W CV NEW EXTERIOR WALLS' 2"X6"WOOD STUD. R-19 FOIL FA HIGH DENSITY INSULATION UNLESS OTHERWISE NOTED, PROV SCREEN DOOR UNITS FOR ALL EXT DOORS REGULATIONS OF THE N Y.B.F.0 AND A CERTIFICATE FROM THE N Y.B.F.0 IS TO y 2. BEFORE COMMENCEMENT OF WORK, THE CONTRACTORS SHALL FURNISH THE BE PRESENTED TO THE OWNER AT THE COMPLETION OF THE JOB. BY OR APPROVED EQUAL. " OWNER AND ARCHITECT WITH COPIES OF ALL REQUIRED INSURANCE AND � EXISTING INTERIOR PARTITION TO REMAIN PROV 1 LAVER 1/2" GYP BD O WORKER'S COMPENSATION CERTIFICATES AND NAMES OF ALL SUBCONTRACTORS. BOTH SIDES OF EXISTING WOOD STUDS, CUR PINE 4" COLONIAL BASE TRIM. NEW ROOF: R-30 KRAFT-FA. INSULATION BY'CERTAINTEED' OR APPROVED EQ. EX EXISTING DOOR TO BE STRIPPED, REPAIRED & RE-USED. PROV NEW HARDWARE NOTE: THE OWNER SHALL PROVIDE ALL LIGHTING FIXTURES UNLESS OTHERWISE CRAWL SPACE. R-19 KRAFT-FA. INSULATION WITH PROPER WIRE TIES NOTED. ALL OTHER ELECTRICAL EQUIPMENT AND MAT'L. TO BE SUPPLIED BY THE 3. THE CONTRACTORS SHALL BE RESPONSIBLE FOR ALL DIMENSIONS AND NEW EXTERIOR PARTITION- 2" X *'WOOD STUD WALL W/ 1/2" CDX PLYWO. INSTALLED AS PER N.Y.S. BUILDING CODE INTERIOR DOOR- 26"X 68" SOLID PINE DOOR WITH RAISED PANELING. PROV. ELECTRICAL CONTRACTOR. n CONDITIONS ON THE JOB, THE ARCHITECT MUST BE NOTIFIED OF ANY VARIATIONS EXTERIOR SHEATHING (TYVEK WRAPPED &TAPED), 6" EXPOSURE PERF WD OO SOLID BRASS HINGES & SCHLAGE HARDWARE R' a NEW BASEMENT: R-10 RIGID FOAM 2D" BELOW GRADE AROUND ENTIRE F FROM THE DIMENSIONS SHOWN SHINGLES (PROV. 1 COAT BLEACHING OIL), 1/2" GYP BD (SCREWED/TAPED) NOTE: ALL SWITCHES AND RECEPTACLES TO BE 'LUTRON', "DECORA" IN COLOR m -� BASEMENT EINTERIOR DOOR-2 R O N.O.. DOWNLIGHT TRIMS TO BE WHITE. CHR. PINE 4"COLONIAL BASE TRIM, 8 R-t9 FOIL FACE INSUL (HIGH DENSITY) CO '4" X 8'8" SOLID PINE DOOR WITH RAISED PANELING. PROV 4 THE CONTRACTOR SHALL SUPPLY ALL LABOR AND MATERIAL SHOWN ON THE BASEMENT CEILING:ILING: R-19 KRAFT-FA. INSULATION WITH PROPER WIRE TIES SOLID BRASS HINGES d SCHLAGE HARDWARE. � DRAWINGS UNLESS OTHERWISE NOTED. NEW INTERIOR PARTITION- 2" X 4"WOOD STUD WALL WITH 1/2" GYP. BD. INSTALLED AS PER N.Y.S. BUILDING CODE U yD, (SCREWED/-(APED) APPLIED BOTH SIDES. NOTE: PROVIDE MOISTURE O INTERIOR DOORS- PAIR 2'0" X 68" SOLID PINE DOORS WITH RAISED PANELING. DUPLEX ELECTRICAL RECEPTACLE 3 -1 5 THE CONTRACTOR SHALL BE RESPONSIBLE FOR ADEQUATELY BRACING AND RESIST GYP. BD. (GREEN BD.) FOR ALL BATHROOM WALL AND CEILINGS. PROV SOLID BRASS HINGES 8 SCHLAGE HARDWARE O C7 & al PROTECTING ALL WORK DURING CONSTRUCTION AGAINST DAMAGE, BREAKAGE, PROV CEMENT WALL BD FOR ALL TILE AREAS. �GFI DUPLEX RECEPLTACLE/GROUND FAULT INTERRUPT z COLLAPSE, DISTORTION, AND MISALIGNMENT ACCORDING TO ALL APPLICABLE INCDUPLEX SEPARATE CIRCUIT RECEPTACLE u CODES INTERIOR PAINT- TO BE "BENJAMIN MOORE" U.O.N. ONE COAT PRIMER AND 22'-9" r, TWO COATS FINISH (COLORS T.B.D. BY OWNER) SATIN FIN. THROUGHOUT t $ WALL SWITCH 6. THE CONTRACTOR SHALL PAY FOR AL PERMITS, FEES, AND COSTS RELATED TO U.O,N ALL TRIM SEMI-GLOSS. T-2" $14'-3" a 4-WAY WALL SWITCH P. v� THE WORK OF THIS CONTRACT CONTRACTORS SHALL INITIATE ALL REQUIRED r z INSPECTIONS OF ALL WORK COMPLETED UNDER THIS CONTRACT — — — — — — — — — — — — — — — — — $a 3-WAY WALL SWITCH $s 5-WAY WALL SWITCH V w 7 THE CONTRACTOR SHALL AT ALL TIMES KEEP THE PREMISES CLEAN AND IS • • B CEILING MOUNTED JUNCTION BOX RESPONSIBLE FOR REMOVAL OF ALL RUBBISH FOR ALL TRADES FROM THE JOB SITE. L _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ PLUMBING LEGEND : jaJs WALL MOUNTED JUNCTION BOX e ANY "EXTRAS" FOR ALL OR LEGITIMATE UNFORESEEN CONDITIONS SHALL BE DOCUMENTED WITH THE COST OF APPROVAL BY OWNER OR HIS AGENT PRIOR TO '� rl STARTING ADDITIONAL WORK. �P PROVIDE ALL NECESSARY PLUMBING ROUGHING AND VENTING AS INDICATED •�, 0 RECESSED DOWNLIGHT (1 OUw) "LIGHTOILER' OR APPROVED EQUALON 9 DOUBLE JOISTS ARE TO BE INSTALLED UNDER ALL WALL PARTITIONS RUNNING BUILDING CODES THAT HATA APPLY TO WORK BEING COMPLETED, PROV AL. FOLLOW ALL NECESSARY N.Y.0 AND L y OF EXTERIOR MOUNTED DOWNLIGHT (10OW) ^ PARALLEL TO THE FRAMING PROVIDE DOUBLE HEADER JOISTS AT ALL OPENINGS. NECESSARY DRAIN VALVES. {�O REFER TO CONSTRUCT DRAWINGS FOR SIZES 0 ,p1 mi, WALL MOUNTED DUAL SPOT LIGHT OF PROV. FLOOR DRAIN AND 10. GAL SUMP, 1 NEW CEILING MOUNTD 10. ALL FRAMING LUMBER TO BE DOUGLAS FIR #2 CONS GRADE OR BETTER M ` / OFF FAN/LIGHT WITH DUAL SW SWITCH AOT WBOX REESSED ALL F ROAN"HEAVY DUTY US IT 11 THE CONTRACTOR SHALL PROVIDE SHOP DRAWINGS FOR ALL SPECIAL WORK OHB PROVIDE FROST FREE HOSE BIBS ` 617 OR APP. EQUAL. SUCH AS BUT NOT LIMITED TO MILLWORK, SPRINKLER SYSTEMS AND STEEL WORK. ALL SHOP DRAWINGS NEED THE APPROVAL OF THE ARCHITECT BEFORE * I• S� �E EXT MOUNTED LIGHT WITH FAN 5 SHOWER HEAD PROCEEDING \` 1/ OSD SMOKE DETECTOR/CARBON MONOXIDE DETECTOR, TO BE HARD WIRED TO CENTRAL CONTROL BOX 6 6 LINE OF DECK ABOVE T NEW TELEPHONE RECEPTACLE FLOORING LEGEND : WINDOW LEGEND : v� `� _ 25-3" <C CABLE TV RECEPTACLE W HARDWOOD FLOORING-SELECT WHITE OAK 2 1/4"W., 15LB. FELT., NOTE: ALL INTERIOR CASING TO BE STANDARD COLONIAL CASING CLEAR PINE � ` ' ® 3 FINISH COATS OF OIL BASED SATIN POLYURETHANE UNLESS OTHERWISE NOTED U p VACUUM OUTLET (PROVIDE NECESSARY CLEC. POWER) SUB-FLOOR-USE 3/4"THICK PLYWOOD GLUED AND NAILED DOTE: ALL WINDOWS TO BE TO BE MA ONALLOW FOR EXTENSION VI INTEGRITY NTAIJAMBS FOR RD MARVIN HARDWARE. f — — ) 13-7 — T-0" 10'-9" g'-10" 12'-9" z 0 SUB FOR TILE AREAS TO BE SCREWED AND GLUED. CONIC BLOCK WALL COLOR TO BE WHITE. PROV. SCREENS FOR ALL WINDOWS. W } >> f — 1 r - - 1 f - - 1 ® EXISTING WOOD FLOOR TO BE SANDED & REFINISHED W/2 COATS SATIN EE= J,�I EE- E_ � __ ---_ W REF POLY. (TVP. ALL AREAS) PATCH ALL AREAS AS REQUIRED) AO CAWN 2432 OB CAWN 2428 © CUDH 1612 — 1 III _I - !/1 Z 3•_4" V CERAMIC TILE - "AMERICAN OLEAN" TILE OR APP EQ. TILE TO BE INSTALLED O CUDH 1620 EO CUDH 2020 FO CUDH 2024 OVER 1/2" CEMENT BOARD U.O.N. WALL AND FLOOR GROUT TO HAVE ©CUDH 2620 OH CUDH 2624 JO CUDH 2626 \I, — WATERPROOF ADDITIVE MIXED IN CUDH 3224 CUDH 3228 M CUDH 3616TT-7"HEATING/AC : CUDHP 6062 OO CUDHP 6854 CUDHP 6858 - TN 6I BELOW GRADE STING ( YP ALL.) III III @O2'CCA FJ Q CCMP 4060 EXISTING WINDOW M7' FLOOR REGISTER (7" SUPLY DUCT) V.I.F. f DUCTWORK IN FLOOR BELOW O © — III ®� 1 f lr 1 f (ROUTING SUBJECT OT CHANGE) ® SUPPLY REGISTER (CEILING) V.LF. f— - - - - —UP - - - —� III III III III \ l LINE OF DECK ABOVE, LL RETURN REGISTER (WALL) / p12" O C (TY B @12" O C. (TYP ) O T-11" /, X 10" CCA FJ. ABOV? T_g" 2' X 10' CCA FJ. ABOVE RETURN REGISTER (CEILING) i2 L III III III III _ z 1 F. �- 'le III✓ 30'-2' KITCHEN EXHAUST REGISTER (CEILING) 32'-9" V.IF - - - - - - - - - - - - - - - - - } -i= - - - - - _ - � O sx VIF J6 VIF 2'-6" - - - D _ I LA — - - — - - - -' - - , III _ — ) ----- -- -- -_-_-- _._ -- -------- - ------- --- �--� I i .I - - - - - {- - — — — - - - - � - - - — - - -I L - - - - - - - - - - - - - - - PII '� - - - - - - - - 111 - - - - - - - , r - - 1 W v-w .1 F T , VE VIF O.. LF, III Q 2-6 13-6"5'-8" .I F \ � WJB S I III S III IV I F III Z o � Q _ _ _ _ III �I� I I I � � ,_6,. �C - I VIF - / 2WW 3'-3" �._ — - - -_ -_ III W a - - -g 5 - r - - - - - - - J II II T III — — I -� D - - - «3 Vl1F" III ( - 1 -' r 1 - 1 I� _ _ �B - - A. II _ LL suPEesmaE JO �9 . III Xm t� I III F— Y1'F ir r � ) f 11 �H f - - 1 - - - _ - r J III EXISTING P CONIC FTNG, - - _ - _- _ - - - - - -- f - - 1 O �i � O36" BELOW GRADE CTYP ALL )AI — _I I , I — — — - - - r� -- - - -I— - 2 12-5" o C7 " X 1 O" CCA FJ. ABOVE III W D X INS E O • '.. sjr1 _ - Js i�de III V I,F �2 X 10"C CF(TYP OV O O L J. (9�12 N N N 6' 0 [mn.�s —� �VI�e,. - - - r - - — - - 1 r " r — , 1 - - -- - -� ,,,�j I�,, — — — — — _ — w O N II II I VLF _ L - - - - - - - - - - - - - - - - - - - _ - - — _ _ — t�FRr- - - - - - - - - - - - - - - - - T. - - J — _ — _ — N 0 I — BI — L III FILE NAME 0jo T _ I -- -- - - � I- - - „ _- -I \ O - T �11 ' ---- 24'-4" - -_ � - � - �X1O" CCA FJ ABOVE III 2" X 1O" CCA FJ ABOVE III 10 T' 36 FER OCP CUR _ J _ III 61 III III Ei� � � F III - ., _� �1 14 _ — — —= ---= DEE (Tv ) 1-a-o1 N c I i2 Xffv�o2C0 CF TYP IO VE \\\ ISTING FTPJG III III III \ ` 'i' III II _ P P SCALE \ C�12 O,C. (TVP ) n 12 O C (TVP ) CLEAN OCOMP NIC FI LO—� - -- - -I - - - - - 8 ] ( \\ \� % G2" X10" CCA FJ. ABOVE III III N�T�eLy 1/4°= l 'Q" L V . 4 3 ©12" O C (TYP ) 'III III III III � DWG NAME' n FOUNDATION 1 f �r f 1 f1 f 1 f 1 r �rl f11(-- 1 f 1 f — r1 - - - - 9'-4• vIF - - - - J � �� a i z1e .•. _ PLAN - - - - - - / — - - - - - — — — _ — — — — - - - 9,_9„ — — 021 • - \ f 1 f / p-g 7�_9„ 7._9" 12'-0„ ?ry] S) �51 DWG. NO 13' ]r0T'1:.C4i:.'P4L31111"•" �. THESE DRAWINGS AS INSTRUMENTS OF SERVICE, EXISTING P.CONC FTNG `-LINE OF DECK ABOVE ARE THE SOLE PROPERTY OF THE ARCHITECT A . 0 FOUNDATION PLAN SH REVISIONS,CHANGES, U W RI TEN AUTHORIZATION 36" BELOW GRADE (fVP ALL.) SHALL ARCHITECT WITHOUT WRITTEN AUTHORIZATION BY THE ARCHITECT ANY REPRODUCTION W PART - - OR WHOLE IS STRICTL Y PROHIBITED BY LAW GENERAL NOTES : CONSTRUCTION LEGEND : INSULATION NOTES : PLUMBING LEGEND : ELECTRICAL LEGEND : 1. ALL WORK SHALL COMPLY WITH FEDERAL, STATE, AND LOCAL BUILDING CODES EXISTING EXTERIOR PARTITION TO REMAIN. PROV. 112" GYP. EDI & R-15 HIGH EXISTING EXTERIOR WALLS: 2"X4" WOOD STUD, R-15 HIGH DENSITY INSULATION c �+ AND ORDINANCES DENSITY INSULATION TO ALL EXISTING EXTERIOR WALLS. BY'CERTANTIEED' OR APPROVAL EQUAL OP PROVIDE ALL CONSTRUCTION NECESSARY PLANPLUMBING ALL ROUGHING AND VN Y.C.VENTING N.Y.INDICATED NOTE: ALL ELECTRICAL WORK TO BE IN ACCORDANCE WITH THE RULES AND a NEW EXTERIOR WALLS: 2"X6"WOOD STUD R-l9 FOIL FA. HIGH DENSITY INSULATIONREGULATIONS OF THE N.Y.B.F.U. AND A CERTIFICATE FROM THE N.Y.B.F.U, IS TO 2. BEFORE COMMENCEMENT OF WORK, THE CONTRACTORS SHALL FURNISH THE BY'CERTAINTEED' OR APPROVED EQUAL BUILDING CODES THAT APPLY TO WORK BEING COMPLETED. PROV ALL BE PRESENTED TO THE OWNER AT THE COMPLETION OF THE JOB. Ln EXISTING INTERIOR PARTITION TO REMAIN. PROV 1 LAYER 1/2" GYP BD. NECESSARY DRAIN VALVES. �� OWNER AND ARCHITECT WITH COPIES OF ALL REQUIRED INSURANCE AND BOTH SIDES OF EXISTING WOOD STUDS CUR PINE W COLONIAL BASE TRIM NEW ROOF: R-30 KRAFT-FA. INSULATION BY 'CERTAINTEED' OR APPROVED EQ. NOTE: THE OWNER SHALL PROVIDE ALL LIGHTING FIXTURES UNLESS OTHERWISE O WORKER'S COMPENSATION CERTIFICATES AND NAMES OF ALL SUBCONTRACTORS CRAWL SPACE: R-19 KRAT-FA. INSULATION WITH PROPER WIRE TIES OF PROV. FLOOR DRAIN AND 10 GAL SUMP NOTED. ALL OTHER ELECTRICAL EQUIPMENT AND MATL TO BE SUPPLIED BY THE �r 3 THE CONTRACTORS SHALL BE RESPONSIBLE FOR ALL DIMENSIONS AND NEW EXTERIOR PARTITION- 2" X 4"WOOD STUD WALL W/ 1/2" CDX PLYWD INSTALLED AS PER N Y S. BUILDING CODE ELECTRICAL CONTRACTOR. UU EXTERIOR SHEATHING (T VEK WRAPPED & TAPED), e" EXPOSURE PERF WD fN CONDITIONS ON THE JOB. THE ARCHITECT MUST BE NOTIFIED OF ANY VARIATIONS NEW BASEMENT. R-10 RIGID FOAM 2'0" BELOW GRADE AROUND ENTIRE OHB PROVIDE FROST FREE HOSE BIBS NOTE: ALL SWITCHES AND RECEPTACLES TO BE 'LUTRON', "DECORA" IN COLOR D h SHINGLES (PROV 1 COAT BLEACHING OIL), 1/2" GYP. BD.(SCREWED /TAPED) a FROM THE DIMENSIONS SHOWN BASEMENT PERIMITER, CUR PINE 4" COLONIAL BASE TRIM, & R-19 FOIL FACE INSUL (HUGH DENSITY). O.N 0 . DOWNLIGHT TRIMS TO BE WHITE. 4, THE CONTRACTOR SHALL SUPPLY ALL LABOR AND MATERIAL SHOWN ON THE BASEMENT CEILING, R-19 KRAFT-FA. INSULATION WITH PROPER WIRE TIES OS SHOWER HEAD z yl DRAWINGS UNLESS OTHERWISE NOTED. NEW INTERIOR PARTITION- 2" X 4"WOOD STUD WALL WITH 1/2" GYP. BD INSTALLED AS PER N.Y S BUILDING CODE NOTE: ALL OUTDOOR LIGHTS AND PORCH LIGHTS ARE CONTROLLED BY TIMERS O t _,. (SCREWED/TAPED) APPLIED BOTH SIDES. NOTEPROVIDE MOISTURE LOCATED IN ELECTRIC PANEL U 5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ADEQUATELY BRACING AND RESIST GYP BD. (GREEN BD.) FOR ALL BATHROOM WALL AND CEILINGS, ROTEC RNG ALL WORK DURING CONSTRUCTION AGAINST DAMAGE, BREAKAGE, PROV. CEMENT WALL BD. FOR ALL TILE AREAS. O DUPLEX ELECTRICAL RECEPTACLE 7 z m N COLLAPSE, DISTORTION, AND MISALIGNMENT ACCORDING TO ALL APPLICABLE q7 r CODES INTERIOR PAINT- TO BE "BENJAMIN MOORE" U O N ONE COAT PRIMER AND TWO COATS FINISH (COLORS T.B.D BY OWNER) SATIN FIN THROUGHOUT (PGRI DUPLEX RECEPLTACLE/GROUND FAULT INTERRUPT U.O.N. ALL TRIM SEMI-GLOSS 6. THE CONTRACTOR SHALL PAY FOR AL PERMITS, FEES, AND COSTS RELATED TO `1 C zDNE, msc DUPLEX SEPARATE CIRCUIT RECEPTACLE P. THE WORK OF THIS CONTRACT CONTRACTORS SHALL INITIATE ALL REQUIRED � � zoNE I INSPECTIONS OF ALL WORK COMPLETED UNDER THIS CONTRACT DOOR LEGEND : r $3 3-WAY WALL SWITCH $q 4-WAY WALL SWITCH V w 7 THE CONTRACTOR SHALL AT ALL TIMES KEEP THE PREMISES CLEAN AND IS $ WALL SWITCH Je CEILING MOUNTED JUNCTION BOX I-� D RESPONSIBLE FOR REMOVAL OF ALL RUBBISH FOR ALL TRADES FROM THE JOB SITE / JS TJJB WALL MOUNTED JUNCTION BOX fTl � Qi NOTE' ALL INTERIOR CASING TO BE STANDARD COLONIAL CASING CLEAR PINE \ III \ / , _ -- III RECESSED DOWNLIGHT (100w) "LIGHTOILER" OR APPROVED EQUAL S. ANY "EXTRAS" FOR ALL OR LEGITIMATE UNFORESEEN CONDITIONS SHALL BE UNLESS OTHERWISE NOTED PROV SCREEN DOOR UNITS FOR ALL EXT DOORS �y, - _ __ DOCUMENTED WITH THE COST OF APPROVAL BY OWNER OR HIS AGENT PRIOR TO b \ Z NEI u h P STARTING ADDITIONAL WORK. Ex EXISTING DOOR TO BE REPAIRED 8 RE-USED n,� WE ��TF EXTERIOR MOUNTED DOWNLIGHT (I DOW) `u U N V 1, '11� III p }U WALL MOUNTED DUAL SPOT LIGHT PARALLELossissiq 9. EJOISTS ARE TO BE TO THE FRAMINGPINSTALLED UNDER ALL WALL ROV DE DOUBLE HEADER JOISTS AITI ALL OPENINGS C) SOLD BRASS HINGES & SCHLAGE HARDWARE NG EXTERIOR DOOR- 3'6`X IGE WITH RAISED PANELING PROV, ✓ ` 1 1�I .. III \ III Ja NEW CEILING MOUNTED JUNCTION BOX FOR RECESSED EXHAUST REFER TO CONSTRUCT DRAWINGS FOR SIZES. III �FF FAN "BROAN" HEAVY DUTY UNIT OR APP EQUAL 10 ALL FRAMING LUMBER TO BE DOUGLAS FIR #2 CONS , GRADE OR BETTER O EXT ERIIOR POOR- SOLID BRASS HINGES &618" SINGLE FRENCH DOOR AND HARDWARE SIDELIGHTS WITH RAISED 6a \ 11 THE CONTRACTOR SHALL PROVIDE SHOP DRAWINGS FOR ALL SPECIAL WORK �\ EXTERIOR DOORS- 3'2"X 6'PROV SOLID BRASS HINGES & SCHLAGE HARDWARE SOLID PINE DOOR WITH RAISED PANELING 1 \� III III 1$11 EXT MOUNTED LIGHT WITH FAN SUCH BUT NOT LIMITED TO. MILLWORK. SPRINKLER SYSTEMS AND STEEL WORK. V E, TNI I ALL SHOP DRAWINGS NEED THE APPROVAL OF THE ARCHI I"ECT BEFORE •�, OS, SMOKE DETECTOR/CARBON MONOXIDE DETECTOR TO BE � PROCEEDING. C4) PROV PROV EXTERIOR OL DDOOR- BRASS HINGES &STATIONARY HLAGEFRENCH HARDWAREDOOR WITH RAISED PANELING / M^ J III 11 \ III d T NEW TELEPHONE RECEPTACLE HARD WIRED TO CENTRAL TROL BOX ISSOLID AS HINGES & SCHLAGE HARDWAREIH RAISED PANELING N 9 L I� _ _ � _\ III I d C CABLE RECEPTACLE FLOORING LEGEND : V\EXTERIOR GGORAISED PANELING ZbNE ,7I Ofi PROV &I SOL DBR SS HINGES & SCHLL AGE HARDWARFDv VACUUM OUTLET (PROVIDE NECESSARY ELEC. POWER) W HARDWOOD FLOORING-SELECT WHITE OAK 2 1/4"W , 15LB FELT tl ® (3 FINISH COATS OF OIL BASED SATIN POLYURETHANE EXTERIOR DOORS-BRASS HINGES & SCHLAGE HARDWARE,RIEH RAISED PANELING. III III U NOTE' PROVIDE TEN LIGHT FIXTURES SUB-FLOOR-USE 3/4" THICK PLYWOOD GLUED AND NAILED THROUGHOUT DRIVEWAY WITH z 0 SUB FOR TILE AREAS TO BE SCREWED AND GLUED O EXTERIOR DOORS-2'8"X 6'8" SOLID PINE DOORS WITH RAISED PANELING, HB ONE OPERATING SWITCH W 'I O PSOLID BRASS HINGES & SCHLAGE HARDWARE. ® WOOD O DDREFINISHED TI EXTERIOR PINE DOORS WITH RAISED PANELING I I \ \ FIVE LIGHT FIXTURES REF BE THROUGHOUT LANDSCAPE WITH OAHPROV SOLID BRASS HINGES & SCHLAGE HARDWARE ONE OPERATING H PINE DOORS RAISED PANELING Q Z Pgov SZONE TIMER FOR PROV BRASS HINGES & Suj OHLAG HARDWARE CRAMC TIAMERICANGLEAN' TILE OR APP EO. TIE TO BE INSTALLED INTERIOR DOORS- Z 10 EXTERIOR LIGHTING PROV. / W ® OVER 1/2" CEMENT BOARD U.O,N WALL AND FLOOR GROUT TO HAVE INTERIOR DOORS- 24" X &W SOLID PINE DOOR WITH RAISED PANELING, SUB-PANEL OVERIDE WATERPROOF ADDITIVE MIXED IN 11 PROV SOLID BRASS HINGES & SCHLAGE HARDWARE ZONE -cAggoqT LIGHTS - ZONE 2 PORCH LIGHTS ZONE 3-PORCH LIGHTS / ` i I ZO/ NEZ ZONE2 W Z2� 12 INTERIOR DOORS- 2'6" X 6'8" SOLID PINE DOOR WITH RAISED PANELING. zoNE n-Pogcli LIGHTS / III 1 - / O PROV SOLID BRASS HINGES & SCH AGE HARDWARE ZONE s-PORCH LIGHTS B ,6-NE z WINDOW /�\� //�\� ZONE 9.IANOSCAPE LIGHTS V V I N D O Y V LEGEND : ZONE]-LANOSCAPE LIGHTS NEW 300 AMP, 13 INTERIOR DOOR- 3'08 X 6' SOLID PINE DOORS WITH RAISED PANELING. ZONE 3-LANDSCAPE LIGHTS Fl PANEL INT I HINGES & SCHLAGE HARDWARE 1 � , NOTE ALL INTERIOR CASING TO BE STANDARD COLONIAL CASING CLEAR PINE UNLESS OTHERWISE NOTED 14 PROV SOLID BRASS X 6-B' SOLID PINE DOORS WITH RAISED PANELING. PROV SOLID BRASS HINGES & SCHLAGE HARDWARE �� NOTE' ALL WINDOWS TO BE MARVING INTEGRITY WITH STANDARD MARVIN HARDWARE INTERIOR DOORS-24" X 68" SOLID PINE POCKET DOOR WITH RAISED PANELING. T' 8 I DIVIDED LITES TO BE IN TRANSOMS ONLY. ALLOW FOR EXTENSION JAMBS FOR AN W 16 PROV SOLID BRASS HINGES & SCHLAGE HARDWARE _ UP DN. 'CONC. RL OCK WAI_I COLOR TO BF WHITE PROV SCREENS FOR Al L WINDOWS - N 12 / ./ +- —/ W INTER SOLID BRASS HINGES & SCHLAGE HARDWARE ISSOLID PINE DOORS WITH RAISED PANELING 106 PROVG B IL R I I -/A CAWN 2432 © CAWN 2426 © CUDH 1612 I - -I Il - - -- _ - - - __ - yJ� O �IHJ' ZONE I mW' CUDH 1620 EO CUDH 2020 FO CUDH 2024 J J� \ L �E' E �E- NE ZONh13 ® \ JB ZONE2 ZONE 20NE2 OG CUDH 2620 OH CUDH 2624 JO CUDH 2626 1 4 -- 105 108 107 I REF /- -- - / REF / / _Je _ - L-- - - - - _-� - - -L- -- - - GPI - _-- -_ - -_-- - -�- - Z KO CUDH 3224 ©CUDH 3228 OM CUDH 3616 F_ U GPI J J - _ O ON CUDHP 6062 OO CUDHP 6854 CUDHP 6858 / �I I - HB J I 61 ©CCMP 4060 ®EXISTING WINDOWJ ®a'GFI o _ - P P C T e• - - -?"' _ - _ Q u"-cL? REF. i \\ HEATING/AC : w F- _ _ fir' FLOOR REGISTER peN" SUPLY DUCT) �p \ \/ - - - ?�� 'i' 111 �I J 1V ® Q DUCTWORK IN FLOOR BELOW Ja / - ' -- REF P (ROUTING SUBJECT OT CHANGE) I -I =x. a a- - Lr. ^,y, ® SUPPLY REGISTER (CEILING) \\ �\\ e \ \ - � / - _ \ - - - / ® \� I TIC da ;GR¢�1 � lo • A / ,, 111 _ I / SD REFI RETURN REGISTER (CEILING) \�\ � / `� * --- 1 / ® �}ypp j 11 REF. Ja a I OI Q RETURN REGISTER (WALL) Z KITCHEN EXHAUST REGISTER (CEILING) 12v ( - _ ___ i F L 01 c�/) EX 6 _ / JB V / / II � A� W LU GFI I _ 101 1 V S'-10 e H / JB D --- 7 p11 I I I O PROVIDE 9'-6" TRAY CEILING v a I 1 IN NEW E LK EXTENSION I REF 1 JB .8 SD / I I 1 e E zG a J 1 ' - J j s I / � I�' I 11g - r 1r 17 1 _ / I jF - _ )F _1E ® GFI (' 140 0 D w Q _ v I / 1 REF F C I Z SUNROOM_ /V i 0 O L \1 Ll 9 (PROPOSED) I �' — ZONE —� � ZONE 3 H - DI �E > - vreeae oil aw - u r SC _ T _ I T q D N JB -I'- -- - S.0 P 5 P SC P FI J p SC P GFI I 1 JB 3 '` ] ], - W O O ply \Y� _ _YY��Y11I IQ GF10 . FILE NAME: FER ICP CUR 03/01/02 - - - - - ' - - - = =-_ E \ / 40 ZONE 4 ZONE a ZONE-. — _ - / — — — p 3 -_ _l 1I __ I / zDNE� - - - - _ _ _ - - - - . zo - - - - - z - - CAL - ZONE NE a -- — _ _ _ _ _ _ ONES_ _ _ JB '�, JR �; i - - �� '"�'�/� , /4"_ III - - - - - - _ --_ -- - q ` Eq DWG NAME' GH — — G — G— — — — — — — — — — bNdo2)2b�r`®� FIRST FL. — — — — — — — — — — — — — — — — — — He — — — — — — — — �y'�nFiiBIFh� � PLAN it 102 102 DWG. NO THESE DRAWINGS AS INSTRUMENTS OF SERVICE. ARE THE SOLE PROPERTY OF THE ARCHITECT FIRST FLOOR P LA ISI SH REVISIONS,CHANGES,AND/OR MODIFICATIONS SHALLSEALLOEM WITHOUTWRITTENAUTHORIZA TION A. ORTHE ARCHITECT ANV REPRODUCTION W PART ' - -- - - - - - OR WHOLE IS STRICTLY PROHIBITED BY LAW GENERAL NOTES : CONSTRUCTION LEGEND : INSULATION NOTES : WINDOW LEGEND : - - - -- - -- - - - - ELECTRICAL LEGEND : r� l. ALL WORK SHALL COMPLY WITH FEDERAL, STATE, AND LOCAL BUILDING CODES EXISTING EXTERIOR PARTITION TO REMAIN. PROV. 1/2" GYP BD. & R-15 HIGH EXISTING EXTERIOR WALLS: 2"X4" WOOD STUD. R-15 HIGH DENSITY INSULATION NOTE: ALL INTERIOR CASING TO BE STANDARD COLONIAL CASING CLEAR PINE rV 1 U AND ORDINANCES, DENSITY INSULATION TO ALL EXISTING EXTERIOR WALLS BY'CERTANTIEED' OR APPROVAL EQUAL UNLESS OTHERWISE NOTED NOTE ALL ELECTRICAL WORK TO BE IN ACCORDANCE WITH THE RULES AND L I I REGULATIONS OF THEN Y B.F.U. AND A CERTIFICATE FROM THE N,Y.B F U IS TO .2. BEFORE COMMENCEMENT OF WORK, THE CONTRACTORS SHALL FURNISH THE EXISTING INTERIOR PARTITION TO REMAIN. PROV. 1 LAYER 1/2" GYP. BD NOTE. ALL WINDOWS TO BE MARVING INTEGRITY WITH STANDARD MARVIN HARDWARE BE PRESENTED TO THE OWNER AT THE COMPLETION OF THE JOB rn DIVIDED LITES TO BE IN TRANSOMS ONLY, ALLOW FOR EXTENSION JAMBS FOR AN 8" OWNER AND ARCHITECT WITH COPIES OF ALL REQUIRED INSURANCE AND BOTH SIDES OF EXISTING WOOD STUDS. CLR PINE 4" COLONIAL BASE TRIM. BV'CERTAINTEED' OR APPROVED EQUAL. CONC. BLOCK WALL, COLOR TO BE WHITE. PROV SCREENS FOR ALL WINDOWS NOTE, THE OWNER SHALL PROVIDE ALL LIGHTING FIXTURES UNLESS OTHERWISE r O WORKER'S COMPENSATION CERTIFICATES AND NAMES DI ALL SUBCONTRACTORS NEW ROOF: R-30 KRAFT-FA. INSULATION BY'CERTAINTEED'OR APPROVED EO. NOTED. ALL OTHER ELECTRICAL EQUIPMENT AND MAT'L. TO BE SUPPLIED BY THE ( ) •'3. THE CONTRACTORS SHALL BE RESPONSIBLE FOR ALL DIMENSIONS AND NEW EXTERIOR PARTITION- 2" X 4" WOOD STUD WALL W/ t/2" CDX PLYWD. ELECTRICAL CONTRACTOR. \moi// a EXTERIOR SHEATHING (TYVEK WRAPPED & TAPED), 6" EXPOSURE PERF. WD. AO CAWN 2432 B CAWN 2428 C CUDH 1612 7 CONDITIONS ON THE JOB THE ARCHITECT MUST BE NOTIFIED OF ANY VARIATIONS CRAWL SPACE: R-l8 KRAFT-FA. INSULATION WITH PROPER WIRE TIES NOTE ALL SWITCHES AND RECEPTACLES TO BE 'LUTRON'. "DECORA' IN COLOR O O SHINGLES (PROV. 1 COAT BLEACHING OIL 7/2" GYP. BD.(SCREWEDI/TAPED O FROM THE DIMENSIONS SHOWN. )' ) INSTALLED AS PER N.Y.S BUILDING CODE. CUR. PINE 4" COLONIAL BASE TRIM, & R-19 FOIL FACE INSUL (HIGH (DENSITY) OD CUDH 1820 EO CUDH 2020 FO CUDH 2024 ONO DOWNLIGHT TRIMS TO BE WHITE ._. 4. THE CONTRACTOR SHALL SUPPLY ALL LABOR AND MATERIAL SHOWN ON THE NEW BASEMENT: R-10 RIGID FOAM 2'0" BELOW GRADE AROUND ENTIRE m DUPLEX ELECTRICAL RECEPTACLE z o NEW INTERIOR PARTITION-2" X 4"WOOD STUD WALL WITH 1/2" GYP BD. ©CUDH 2620 OH CUDH 2624 JO CUDH 262fi \ U _ DRAWINGS UNLESS OTHERWISE NOTED. BASEMENT PERIMITER. '"_ RESIST(SCREGYP. B . ( APPLIED BOTH SIDES, NOTE: PROVIDE MOISTURE OK CUDH 3224 ©CUDH 3228 OM CUIDH 3616 moFl DUPLEX RECEPLTACLE/GROUND FAULT INTERRUPT 1^ 5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ADEQUATELY BRACING AND RESIST GYP. BD. (GREEN BD.) FOR ALL BATHROOM WALL AND CEILINGS, BASEMENT CEILING: R-19 KRAFT-FA INSULATION WITH PROPER WIRE TIES O z .. PROV. CEMENT WALL BD. FOR ALL TILE AREAS. PROTECTING ALL WORK DURING CONSTRUCTION AGAINST DAMAGE, BREAKAGE, INSTALLED AS PER N.V.S. BUILDING CODE. ON CUDHP e082 QO CUDHP 8854 ©CU'DHP 8858 Esc DUPLEX SEPARATE CIRCUIT RECEPTACLE COLLAPSE, DISTORTION, AND MISALIGNMENT ACCORDING TO ALL APPLICABLE CODES. INTERIOR PAINT- TO BE "BENJAMIN MOORE" U.O,N. ONE COAT PRIMER AND OO CCMP 4060 ®EXISTING WINDOW $ WALL SWITCH ry TWO COATS FINISH (COLORS T.B.D. BY OWNER) SATIN FIN. THROUGHOUT 6. THE CONTRACTOR SHALL PAY FOR AL U.O.N. ALL TRIM SEMI-GLOSS.PERMITS, FEES, AND COSTS RELATED TO $3 3-WAY WALL SWITCH $a 4-WAY WALL SWITCH % 5-WAY WALL SWITCH a � THE WORK OF THIS CONTRACT. CONTRACTORS SHALL INITIATE ALL REQUIRED DOOR LEGEND INSPECTIONS OF ALL WORK COMPLETED UNDER THIS CONTRACT. - $JB CEILING MOUNTED JUNCTION BOX V p Y THE CONTRACTOR SHALL AT ALL TIMES KEEP THE PREMISES CLEAN AND IS - -- - - - - - ---- - --- - B RESPONSIBLE FOR REMOVAL OF ALL RUBBISH FOR ALL TRADES FROM THE JOB SITEpJs WALL MOUNTED JUNCTION BOX a N NOTE: ALL INTERIOR CASING TO BE STANDARD COLONIAL CASING CLEAR PINE m 8. ANY "EXTRAS" FOR ALL OR LEGITIMATE UNFORESEEN CONDITIONS SHALL BE UNLESS OTHERWISE NOTED. PROV. SCREEN DOOR UNITS FOR ALL EXT. (DOORS. y. RECESSED DOWNLIGHT (100w) "LIGHTOILER" OR APPROVED EQUAL DOCUMENTED WITH THE COST OF APPROVAL BY OWNER OR HIS AGENT PRIOR TO STARTING ADDITIONAL WORK. IN O EXISTING DOOR TO BE REPAIRED & RE-USED EXTERIOR MOUNTED DOWNUGHT (1 DOW) T� �� Q 9 DOUBLE JOISTS ARE TO BE INSTALLED UNDER ALL WALL PARTITIONS RUNNING N{jB PARALLEL TO THE FRAMING. PROVIDE DOUBLE HEADER JOISTS AT ALL OPENINGS. EXTERIOR DOOR-3'8"X B'B"SOLID PINE DOOR WITH RAISED PANELING. PROV. WALL MOUNTED DUAL SPOT LIGHT REFER TO CONSTRUCT DRAWINGS FOR SIZES. (D SOLID BRASS HINGES &SCHLAGE HARDWARE, Q� NEW CEILING MOUNTED JUNCTION BOX FOR RECESSED EXHAUST 10 ALL FRAMING LUMBER TO BE DOUGLAS FIR #2 CONS.. GRADE OR BETTER. 2 EXTERIOR DOOR-5'3"X 6'8" SINGLE FRENCH DOOR AND SIDELIGHTS VNITH RAISED �-EF FAN/UGHT WITH DUAL SWITCH AT WALL. "GROAN" HEAVY DUTY UNIT PANELING. PROV. SOLID BRASS HINGES & SCHLAGE HARDWARE. OR APP. EQUAL, 11 THE CONTRACTOR SHALL PROVIDE SHOP DRAWINGS FOR ALL SPECIAL WORK 4Z'P EXT MOUNTED LIGHT WITH FAN SUCH AS BUT NOT LIMITED TO: MILLWORK, SPRINKLER SYSTEMS AND STEEL WORK. O EXTERIOR DOORS- 3121N 6'8" SOLID PINE DOOR WITH RAISED PANELING. ALL SHOP DRAWINGS NEED THE APPROVAL OF THE ARCHITECT BEFORE PROV. SOLID BRASS HINGES & SCHLAGE HARDWARE • SMOKE DETECTOR/CARBON MONOXIDE DETECTOR: TO BE PROCEEDING, SD HARD WIRED TO CENTRAL CONTROL BOX 4 EXTERIOR DOOR-2'8°X 8'B"STATIONARY FRENCH DOOR WITH RAISED PANELING, O PROV SOLID BRASS HINGES & SCHLAGE HARDWARE. dT NEW TELEPHONE RECEPTACLE y� OEXTERIOR DOORS-5'4"X 6'8" PAIR FRENCH DOOR WITH RAISED PANELLING. Q c PROV. SOLID BRASS HINGES & SCHLAGE HARDWARE. CABLE N RECEPTACLE - OfiEXTERIOR DOORS- 3'3" X 68" SOLID PINE DOOR WITH RAISED PANELINGFLOORING LEGEND : VACUUM OUTLET (PROVIDE NECESSARY ELEC. POWER) Lu p PROV SOLID BRASS HINGES &SCHLAGE HARDWARE. U 0 EXTERIOR DOORS- 4'0"X 6'B" PAIR FRENCH DOOR WITH RAISED PANELLING. 0 O HARDWOOD FLOORING-SELECT WHITE OAK 2 1/4"W., 15LB. FELT �.J PROV SOLID BRASS HINGES &SCHLAGE HARDWARE _ ® (3 FINISH COATS OF OIL BASED SATIN POLYURETHANE O EXTERIOR DOORS- 2'B" X 6'6" SOLID PINE DOORS WITH RAISED PANELLING. I ' I } SUB-FLOOR-USE 3/4" THICK PLYWOOD GLUED AND NAILED. PROV. SOLID BRASS HINGES & SCHLAGE HARDWARE, LLJ SUB FOR TILE AREAS TO BE SCREWED AND GLUED. O EXTERIOR DOORS- 3'6"X 6'8" SOLID PINE DOORS WITH RAISED PANELING. _ Q W PROV. SOLID BRASS HINGES 8 SCHLAGE HARDWARE. I � ZINTERIOR DOORS-2'0" X 6'8" SOLID PINE DOORS WITH RAISED PANELIING. "EXISTING WOOD FLOOR TO BE SANDED & REFINISHED W/2 COATS SATIN 10 INTE SOLID BRASS HINGES &SID PINE HARDWARELLJREF. POLY. (TYP. ALL AREAS) PATCH ALL AREAS AS REQUIRED) INTERIOR DOORS- 2'4" X 8'B" SOLID PINE DOOR W77H RAISED PANELINIG.CERAMIC TILE- "AMERICAN GLEAN"TILE OR APP. EQ. TILE TO BE INSTALLED PROV. SOLID BRASS HINGES & SCHLAGE HARDWARE OVER 1/2" CEMENT BOARD U.O.N. WALL AND FLOOR GROUT TO HAVE INTERIOR DOORS-2'8"X 6'8"SOLID PINE DOOR WITH RAISED PANELINIG.WATERPROOF ADDITIVE MIXED IN. 12 PROV. SOLID BRASS HINGES &SCHLAGE HARDWARE <INTERIOR DOORS-2'8"X B'8" SOLID PINE DOORS WITH RAISED PANELINIGPROV SOLID BRASS HINGES & SCHIAGE HARDWARE- PLUMBING LEGEND : 14INTERIOR DOOR-324X 6'8"SOLID PINE DOORS WITH RAISED PANELINIG PROV SOLID INTER OR ONCCONSTRUCTION PLANS LFOLLLOW ALL NECESSARY N.V.C. AND N.Y.S ATED PROV.ISOLDID ORASOf - - -- - - - - - - _ BRASS HINGES & SCHLAGE HARDWARE. I 1 VIDE ALL " X GE SOLID PINE POCKET DOOR WITH RAISED (PANELING. J a a6" P P LLI •P 5 HINGES & SCHLAGE HARDWARE. _ � - - - - - - - t ' im BUILDING CODES THAT APPLY TO WORK BEING COMPLETED. PROV. ALL 8 18 INTERIOR DOORS-2'8" X 6' " PAIR SOLID PINE DOORS WITH RAISED PANELING. I D •so 11 F tl OPROV. SOLID BRASS HINGES &SCHLAGE HARDWARE. O NECESSARY DRAIN VALVES. • DRAIN AND 10, EIAL.F HB PROVIDEFLOOR FREE HOSE BS, SUMP. DN. JI I DN ® 11 �I1 J�I[LJI'�Je J P •S SHOWER HEAD -- FIK - ._- -..Fi-_ - - K KS`s a• 1 J I -- oFl i' P op Lu HEATING/AC : K ®T' FLOOR REGISTER p" SUPLY DUCT) ---- j P ® / r F M Q -- DUCTWORK IN FLOOR BELOW I\ REF. ® D Z (ROUTING SUBJECT OT CHANGE) ® SUPPLY REGISTER (CEILING) H H =- I / I I // I LLIII 0 RETURN REGISTER (CEILING) OJ , Q Z ^T� RETURN REGISTER (WALL) a ElKITCHEN EXHAUST REGISTER (CEILING) I K EX D REF. _ - - 12 T E -_ _ - I -- • _ - _ so 3 •eD w ¢ cr - -_ - -� - - IC _K LL ❑L T e a GF _ _ LC - eh/ ( - � z QEF / JB -- - - - -- W -_ _�-_ - 'l � '✓JB - _ __ _ _ _ O m -- J6 8,_g, F _ 48 D3 D 7 REF y - _- - _ _ -- - - -- - - -I--_- I 1) _ - - - I' y C *SD T r. ® IwJI -- --- -- - - - - -- -- - - - - -- w - � - - K K FILE NAME'F - - -- - - - - - K - ER 2CP CUR _- - --_ - - -- - - - --- - - __ -- �• T _ 2-28-02 SCALE 91 -- — 41YWI� \md(F'�F I! A4go,P�, 1/4"= y 1011 BV v xJ DWG NAME' B? SECOND FL. T�, do3➢2➢§,.�p� .' PLAN DWG. NO.. THESE DRAWINGS AS INSTRUMENTS OF SERVICE, ARE THE SOLE PROPERTY OF THE ARCHITECT NO REVISIONS,CHANGES,AND/OR MODIFICATIONS SHALL BE ALLOWED WITHOUT WRITTEN AUTHORIZATION A • n BY THE ARCHITECT. ANY REPRODUCTION IN PART G SECOND FLOOR P LAN OR WHOLE IS STRICTLY PROHIBITED BY LAW .. _ . . . � x. _ a �' _ F l T ., a . . ., :. 4 . . . �� ; GENO ,. - T - .a- Iilkl *11n-r F4, A ,.S7AMIEdA•1## A . , W IIk1C#. : � 1f.1>kIC9H - " _ I{1 `.T - �Ia.u.� ., ..,. .a _�"Q131 .r ..' . .�,� -�, E WlThl' �� . ,.�."_ .. .� , ,, . . . �hM,I;SLk,.FiKG�1 L:. H - ,. . . � i i . .. , �, LII ry ME':RU '_ 6 AND _ {. .. ( t9 F)�� . N - �S ;hf� 7UO. R»1C - Lf ., - :, o ,IN.�`': .F^. : - r $.4, Nom.:,. +•... 1 . _ _ _ .. . .-FOI, A• Hf „ . Et .:A. -"d , . , - .4If4 .. RY.d1.' kJ.tATiIEIN., { p- F _ .. � lel' .-. .,: . _ ;j ', .a,1 �, � �•`. ., - _ ':r r" . RfM: E,N.YBF.U. l6 � �_ ,p _ , - -� �'rI�E:OYVNER. TO . - -: - 'S '"M�+ tJAC'• lti"i'�: :"�,: :�',.�. s,. .. ��' p �'�,�,,yyM.. _ '� liW OFT - ^9t! f.Bel�" ,jiE JOB 7. .. ,. . , a- I 6YNR s. , I Nf I F iFf .., 1'*;�k,., MyII�LILAELhp9!i` $HAj„L E ,;. �, ©. '-: + _-. .I'M?OVI ' AL � " '.I Jw1 ,. }, �� $ GSA RQVE„ , _ N - !.1 L EINT 11wK4;FI%TLIAE,S'W LEOTHER", ,r, •,.. , . ! „� - _ _TFf ,lOJf>��4U-ALTJP[".EfL - _ ,, ., .- , _ _ _ _ . : . - _ *ESS 8E UST�E. ,. '- -' - a + - r , . �.,,I,AI�CS ., . . y,, . , . -_ ., _ „ . _ ., ., :: , . _ "` ,I. QTNiI+ri ,E©Wr - :" , ,. rte,.. .: Y� , a a . j 'L1! O;h'f,'WEL1P`fC9 1�I _ AL PMEF)`Y,'AND•fJtATL TtlBL $UPPP' E ' -,: - - ,, -, '�;ON6Akl., lid ,]z, AS firRlhl�ia. ., � - -° 6f.f� - .:. • ..; N. - - / r-'' „ :r - .�,:« q,5. 1 IOM 1AIfTM, T e�/�1JR�cOR. 4P BW THE w ; r � :rues :ria 1 ;. Ma u.o, . c 1 a. . 5, P`. . �, R dcWb MA, - . , Y. N1.),,. ., . 1P. N . StiAT P . .,rRNflz ..-, . .; .. -:, r, ... : , ;13 . r M1F1'Id{ ?P, b1 $ 52-21�BsX ..: . M, 'i , AIA, ,. ' G A (v u'IIaR.. , SH0V4q TW rt�. .. ., .Pilal , . BY „ . pq - .. ,,,,�.,,,,i ;}.PANEtIM'IG, MTa4MP,A ACLE6 TO BE 'LUTRON'; "UEGORA"INCOLOR i1F1Rlje1 'Ulilk, �,t ' , d ,, . . ,. _,. , 'bWNEF,jI 8AT1�N.'FEIIpOW�,R , IC14:IkfSWM' ,, W f76 EAR -"' .. , ,.8Q,4:f.1$',BRAS$:HtMI'$,ES_! NPH�` H�1!1`i'(al E.', . b.W.Q PJO!MYNHT TFIIYI$Td�Wlill'L'. �_ - _ bN77RE - - +^n r p - ,. .;: .,,` . ,...�'f .'. '. : " '• .� „". ," . :. � .r '' '� � - n � � +1, -: _- ' a� �,.u .'; .. . ��, . , AD :,?"�•rY. . . N ?4MNR t�A, F GbRI `- ,' :- . " - - - ,sr} ,r I:,iB . 4-9, _,. -;RA1 br PANELING. DUPLEX ELECTRICAL RECEPTA � x I AA , �IE.�E ISA k . , pRnK,2':I147?J.,.:15LB FELT., BIAS , E �f �k�tBR R'.HIf ,rSt*f�LA R t0 ' L P, ! a l4[.1je111( ' R}:1RIIV :,eL`YSWJ ALS' ; ''¢ „�,'rA, _. 'tB:.F A�I$'Ci.F 'U LI _ : 4` i $'�L''f?y „RA fh'1kJL'ATfQF4 NATH'PI80RER kM'IFIE.TIfi$ ''Ff�� pJ QIP - ,IgNM'E(�AOi ORPIN TO AeL: tPF ': _ kU{ALRIFFaIv1E -� 111 GEOj�E. Fi EX'L" I ' '-. . r. �h `"YJ�. 06F, DUPLEX 0IECEPLTAOLwGAOUND FAULT IM'I RR PTCL Q ORTI AND. ': _ -' b Sli s-„3*17A' XB-B OQO \M71Ti"IfRA{,SED:PANB'Clnl[�r V E /ry 4 cu �f`EARKA 'TFJIG;ILPk- :F,31pP 4,�LIJ. PAh'1D NAILED. _ - �: EGEL1 ,'B�' IrF,'IGHS ND SCHIAnq ~:t4t_PC!Jq�piE, QI86 fiIURLEX$EPARA7E CIRCUIT RECEPTACLE :”, 6•TH S` IA�7�+AS4TL+H HAL-'l,,P,HY FO.,• '_'P.ER 1"i 8',AS1fF4 .BU:,e AP1ER'$TOr j,'�'�W„ ED dkWD GLWED. . . _ TH§:... K.g"�!?'., 5' _ OT' tG4 7$ ,.T O;7Q ,:,:il - - RIgF'i,FFV, I4PH_W.CNC)D OW . 4:�r„X6481,r;FW.Q65U8BL $ W LLBMrCH ,ter I. C 7RAfu T ¢ cEF B S jrynrl��',. =dWA P' c E:'., . RE, . DLlzAN 741J£:oN qPR. EO.T#t E„TO rBLs INET' D', „ , TON$pFALL VJOf1K:COMPLED UN4RR't CCIN�FAC � 9tll� . . SENT. .... , yA1rC.b7�:WALL AND FLOOR GP 6UUTrTL7;'5�,t�#AtwF. A l INSPE, WACERIiR 'F , OPI, .E .. . t11N. 7, THE CONTRAGTQ'R H',r ..AT ALLTI THE -. ,: . „ ° ' ._. ' , . - - a 3-WAY .... ; .r ,.,, ,.r. ., Q© Ei91oRFRENci'IMi'poPpQPR.S a x:6-9' FW©FiB!46�A ¢ . R . Pe4NSI ,E`r"`Ow PRS $;Q AN.I'841& .: , ;- r y _ A EfaB �Ob, �` hID ON e �g ' A WALL SWITCH � � ' , � PRO jF�E$bl9P. ASS'HARO-WARE BY'ANC'pERSON.' r= QI��SIT6., r.- pPf«%l .A.DPdTldNg4 #Ytl ' .. REh•1jP AkLFOR"AL,L'T '�N:p' J �..- U' El)`�,?'.�E`�1f,�k b TO - ,E`ic15"CII+It 'E1QrS M-Yt]F.� IN J3 CEILING MOUNT]IM JUNCTION ago"IORTp . .� NV Y.',GN hI ��`BD � W?,IkL:M©iAN'I'E JWNO'ff BQX” ' 1?' G!MSOX±NPW,Mnt'1, N& .l,t(MN, 11.1'{x. - ' ,, :r _ Fi Ls3E$ I]'-'o4' !'VP'14^JGHT fM1[Jpl,4}'r,l,!SHT0140R'OR APPROVED . •; ' ' AETC1�' N6'f'RIW •T.D - F PAM: 'I, : r EQUAL Q+ J�s10f. FS AVLL., NIN49. _ . 4`�FWWih)g5 FqR 9 _ - "P,RA1,, AT ,+J 1A Gj%L',SVMIP.' s., ,• NOR M41i(51Y+I,TEP H 1 10. AkL FRAM' ” ,� R° kww. _• . . , _ 1 _I'I . _ PBDs r,+ � 1 . Iw�s; reE . � .: . ¢ci ae: kh ib vAµ:L n4OUNT,EOIMUAL�B�OaHT. ING,LWMBER 7O BE-DO1:+q�LaB F{R ii!z OK9Nf, � ,� ,NC1T 11.THE OQNTf"LOT R"4HALL PRQVIFFE S,tiW;17.(,, AWjtq L'i,�FOGAAC9L Q7R FrEIiL V4C7RK .: :',' - . :: : .,:. -, " - "; ._ . . - SUP{I'•AB T'Nggt p AWi ALLS'l" RECEIV9 1,6447 R S.. S H p1 rj 4.TOI M,!kl-WS�Q M"PAIN liLl $Y c. ,EEL',V"V6k _ . . R 4'IJ, :TMRBE.K.f�ATS"h"INIS HQIN A , ,. t : n , ` - N ©SN`+Il l'2.rl' OY, „ - .. R'. 1{�' ', GO°�144?J�t¢A9fNfaT';Rr1;,EAR-F!,11/!E .,AI+LBi!1(}R•Ts1MW4-yVINCdSEf3 THE NFSIti14C7bAL'OF'TWAR 'CK}_. ,+L` pFfE R.RpVIp,$,BBIriflf+rtlN AA- CYFI 'P ., . ;HI^T04M�QUT. 9�.9"IN�TrNISHAN. - ' �, t '' _ .; r;MARft� p '.9TYVflF0G1A1:8 (C,H`AGVALL"rIRORUSF1f £1U' � Rl , AA /4) O /4„ '. 'J>L H . .AH "lEAW bU7Y UIVFT I, OCED ING• NEW WALLS AWO CEILIOCiWITH kGLOSSON ALL DOORS &:TRIM. - IAREdff hAOWNTM.LK#HT WI;fPI AN okw sz ' L/1 '� �.ID 2 m>>gEu�dero'vWi iED''Y�'c�iu7a#ntico"OiLBox ' (31^ f RMlhl} D T NEW'TELEPHONE!RECEPTACLE �"P. +DHSOSS;, - . Q+fDM3a6,E.2' F� sP,r't?�DER-s�9"X J. ` 1*A,=M WIN66W Y SP,004 '41-4"X:T-o" a TRANSOM WNDQ;I O SIZE FLUES AS REQUIRED. Q � z W Ir 4" BRICK CHIMNEY PRQV. R-30 FIBERGLAS INSULATION Q IN ALL ATTIC AREAS'. I Q EXISTING 8!'X 10' R.R. @ q 3"X 12" Mi119gE'BEAM - 7,, 4" BRIOKCHIMNEY //�Y++161 O.C. LLw LL PRQV. FLASHED CRICKET BEHINDIXISTING CHIMNEY. IX. FULL LSIM '"X 1 O"CJ ,(g 18"OCPR V, FLASHEQ CRICKET BEHIND ` P'Ae NECEB�AFiY EXISTING CHIMNEY. 70 BE REP ..ASPHALT ROOF YR.$), NGLES N pp��t� f�,fZ � - y( FUL'k fl'L 2"X - 'dFF'APPFIOVEp EQUAL. 0 BXIS71huIG 8'�SC 190 M pOr BE L�'J .{¢A lip ��. : I 1 '�' ® e PRQV. 1/2"CDX'PLYWGOb SHEATHING. I � tDCISTI�Pq � r - ' y GNP,-�D, ON ALL : TRriN•'70. '' I AND RE .r I &f r I 16# FlELT.BENF.ATH ASPHALT ROOF W EXPOSED BURFAGES� _ n .I 'BHINl�LE6. (l'lrP. ALL RREAS) �.- PROV.'6"GUTTERS. EXISTING 3"X 101!R.R. @ II II I4 rl - 18" O.C. E7CIB`fING FU11:,1„RJNF'2'X!F' "YB"OO 81d1D•. ' EX I, '' ;tlIM. 4'k 10 - I - E7S FULL RIMA: 4"X '10' Y+�4� �� , _ - " W F MIt1 fl'FQIL FA. INBUI�ATION. Q WOgb BElgaFt ,',I . II II `. . �1iLb"AL ALL AI°{6,g8) r S>'X 10�;FWLIWM. F:.1., j C. '.- : . „ _ - 4/4"ASWJIDE CLEAR CEDAR DECK 0 QED A$IN vA 7`t$! Q C"a'T i _ _ I_- , 1"S"SLRERER@18,- O.C. - : X 1 O1'BEA - PVC TORCH DOWN MEMBER ROOF O^ C ' y Ek. I ' . J I' C 3/4^COX PLYWOOD 8" M. STING;CHIMNEY A'ND'NEW PdMC .; ( - - _ 2"X1" CUT AND PITCHED AWAY FROM HOUSE PRQV F4ASH6D ORIOKET BETW�N _ PRQV R'-1B F.IB � O (n Iff CONSTANT FLASH II I�II I� ' EXI � EXISTING FULL DIM. 2"X 4"" ® �', �� y EXPOSE4SUR D ^ GYP BD,Q1N ALL ® 16" O.C. STUD WALLALL) 2"X10"CEILING RAFTERS LL FAOEEE EXf8T1@IG'f90ORS AND _ NEW ASPHALT ROOF SHINGLES 2"X B" R.R. @ 18" O.C. - u . TRIM TQ SANDED HED. i OAF'TIMBERLINE 40 YR. 0, AND REMj MS I I R APPROVED EQUAL. i r u. f!pi - L — J 4"X4" POST LL'SLAC 4) fir. . 9' ' PROV 1/2"CDX PLYWOOD SHEATHING, @j \ 16.R FELT BENEATH ASPHALT ROOF 5 ' � � _ - I SHINGLES. (TYp, ALL AREAS) f 2"XB"C.T. @16" O.c. - , � 2 ", I. A '. I ' • I ( 2"X.1 O" F.J. @ 16" O.C. _ . E RO DJRI:%. " I ' ISTINq . ! ' TRIM .. E"6AWOE'b r 1'3/4"X11'7/8" MICROLAM BEAMS H T OC QQ� a LL w I WW 2"X8" F.J. @18" O.C. WI - - 2"X 6' FULL DIM: OCA SILL PLATE EX 3 10""{FULL DIM1 F C27,�8° O'•O. _ - _ _ TO BE REPLLAOEFDA$:NECESSARY EXISTING 4^BRICK FpUIlpA�:, N TO � - rr F1 LAS - 10" F J. 1 @ 8 O. . SE' r C FOUNDATION PLAN, A'S PEt1" +LF;\ +I�1'FiL['Y/ORS -t0 - AIiIP LA74 Wp (PYP. AL - 75 FILE NA E: FER_4BS_CUR - 03/01/02 ° EXISTING NO TI- ' ,NATIO / T PRflPO ED ADDITION �T ��3��ti ®�� sE�°oN CLEAtI;isE�Mfa °japdnr0 _ DWG, NO.: THESE OgAIWIM[#8 qg INBTRIIMENTB OF SERVICE, AREg7ERyIEgI80LE PFOpER'Ty OF THETAOHITECT. - NO ALL BY�AL 8• p W E8.AN R MOOIF-IlCT jl0NB BY7HE ARCH ANY REPRODUCITONINP ORIZATION " � OR WHOLE 18 8 IOILY PROHIBRED BYLAW, „ „ Mkk ^' IM” "R ^n v- 7 Nr f— CL r vT N ti Ql ffi 'S I FT ilr LL Ell I �I — — - , r .4— —.— - — T x ---_ . __ ----- _ _ - - - _ rte- y ;�"`- _'- - --- --�- ",•� �l �"� x ', ���7 --_ -_ - I , r , I z a R 2 LL Q � NORTH ELEVATION T fplp_ejg�ar,=cwt f� e x NO, to L@WAIHON AVL �W: .OH °E' ITE IBV,p'^�W F A. 4- 1 'I ti I Z w C CL v u-. � cu zj I . 4:n ui LU — — WEST ELEVATION �I o Q a FER_6EI„6V_CUA E owa �E PROPOSED WEST I PIF n ELEVA-noN I T =kkR .P? �NTd �]@ 4F . p� Ma ?HEC171 N6 //� TION . . A.A 8 • R nWr��s y i If MINI■ .,.+," �' n�yv+irYrm�ri y�mrwrrwmn.. :+mwwrwMwc` ,!r•M8NN6N61■! rY TrS�.rmiR•.•r�q ��aavry �o•.'"ii+sniY" �r omrro aYrmx 1n 131H v! it r S•SrZ u irrW�, _---YYwrYY m i='6�S.'�r"rn�w'• "r!r zwmwwa - -___ - rrMMi»r i�av iZ.ra�g'�m}ri.�iieRmwR _ __.. _ _ _ -_ •.wnimrman•�t- _—_ _ —__ __-_ _ rr.R.� Y�sv.Tii T iZ�r��Ya mRisru: Yrmrwmrr�r A wZ�.rS radii ��rrnr �oee{•raMra ' �wirw•�oor'dim "Y'Dein' � .mimrvfieu. rrrwr Y .wR w�rr� m ��CiSr'.i�rd'S x"rii i�M +•_Ol..IYM �YIY�I Y��RY•IIY ,»Wn1Mr� YiWrw� Yrr :• wr �S•rr�TvY��i ', . \ rn•g�reuugs`i a wmiR� .ala riwr•,mrliS :Oi.R.A�� nen�m•�• rr Yv Yn, 1iiNa '7RYi.Ri \'�rrrwmoi w owl ,fir. \w.�Y niS'Y•ir'7 ssnmia:ma�r��.+�mo.r � ' �AI■■■O�IOIOIDo4.\rirY.,m_FE-a:o:rwrr.�.....w,�.........�....��...s...�.,«.�vo....�rr rm »r•r n r�.orYinnrs�. �vw•r' .rl ■li �WiiY�l■��Ny� `\ i..�_ •r.�.o rra��wp.r��r�s�• i" eY. iI AW \ / �••n�r pl.Wm m n miRnMY m�rwr , r v %� i �� .-c®•r•Y;w�•m�rinlir+.�'I --II I�I -- i -- dco! _, ,.,..-_ � _ " \ ■?i1C.1 '- - - fes �Y� �.rj/ .ewMvrsmYwna.p.War�vum»x»wu�;.RRsw,!/ - .raw�Y.la,;-". •.., _x^'. ._.=,uo.�r®.� -- ---' M.�Yi niww .�Wi"".R��:».Y.r+-- � I�I■!• � .•.++R�__.�R�''w".''.. � =-_ .,.., �•w Rre:aaR�' �. 0 NN�EBN6ANN'NiYY1W111iYq■ffiNI�Yi�IfS+1l�I'_•_ _ 'r'i"�'" '+am�ar w�nY.r m '�..��o=i �Jf■FINN' i��v �w m r ° N■l5°N�t7m° "s' a !sN6�,°'NNNiN° XNN�S'X+�Ms{dtx"� � - . - ��Iel"^a�Nk1t&:^0 '�S':�7N;'�Ya' _gqy-�N_ i taXrod �,p�p��_s�:wX.l•� ° . . e...��. �_, �_ -- Xl�°i��°ar"S'�,'.°0 i i 'cru N■■ -- a -- .. .. - � I 491/1 ■� r ' '6NliP� -- sX� zsaalroau�u'��clwpro' � 4 tllr!71r>wFt'-'roda � SNFAa'NI a�X - mr. MM �I � '� q i ■NNS al 9 k; I= 1 'I N■� t' II NNS III �1 �, milli e ffi � � � 5° ��� NOTe I -- I � ■SNC I �� I II I jY7; I�; �, I , ,, '..n s: l..,.,, ..,.. ,>r v,vv.:� 9r.$'wrp+m ..• . . - e. . _ - _ _ �.r _ _ � � 3.,' �N Nla� Oil �r��{y� I'{r'.,� I - v. I a:... �I i �tl,&'.��H�il mm�w.ro I _ - =;r x�'ar Ys yrs m � ,••m•,'.« «..,s.i�,.:« ...I i I. I� ,�'i I�i NNA �3�YII3C.� ;!pd �Nf j y;�$ i I I91303fffi 1OM lawm, _ _ ., �,�..�_ ._. -sI�H't,r. � . I. ., a ' `i"I.�Ib R� � I~ �■ �: , I 'tll�Ir' �r I � ' __ I _: I _ , ' �ANN aNNI■rX■d■wi�'' - _ ., ,s � -. 4 I I, „ I a"��i�.: — - — i i i I I � �,.° �L:. �' a: alp . Ict1a- ly � , ' .I �■■ .� ��_ I ID � ■N■ ,--:_ .--"_._ '� —__ ___ fil I I .. ��: WMwrW», -- I--_ I I !N -� '4' N�$:SiNNll6°6R I� 'fi!iXik'fIIR!N "2 " Irr 'N 'X4'N N tlfllY+ l.� u�lN s - � " - -rtlk�:tiinP.�l!5��8.R5'�'45Y&Mkfl21 illi€4 �.5� � t_E'SF fl'rAtl�' rdN'4RIrLlk* YIffiirx:+i9 L5 i31ifi@ Ingl r°Ial�l�im our'emris fill ruwarps"wnansuawx.Jrnrxm W/ riurusn•p�ll3 a;mX�:ro �jMl'�I�,�}'nk'�I�� $i� ����I i■■'•Ipl�,jl�.�.�!ra,mvll - :- __ — - ��rw� OIRnIMn vipnlYt M JM1,MNd)WJ.HmVl{fl1.PYli4NPInR1liRM�,9•ill:PulRl6nR= tl II!N Ntj �_ I --. _-- ,YMu�auEvfrrcwRirsav.Y.rrwi.vnWiRai®.Rr — - -».rir:»Y,�nr•Y•irni•ar a a.Rn :w �-�'•� p �! a .z `Et .!N ''Nh'f�4'7 RPdiYN■7°I�'■�I � 16NAID7Y: N3N®iNt ' ' ,+°>'. K +ti➢■f6l"t" N�'„ .W..�... .v.�,,,�..., o . .. ,... 73 15B76I1I �r�'�f116J„X1-F.IR�IP'"?J 'Xk:"gYt �" .;N8YY9II=!°�NN'9 Ii I■�FX :sXlk"M.�IAFN'I�iXN1�°"N' O 9"X■■■■■°N■N■ffi-■NIDNII"yNN1MNe3N°9ID6 _ kp-WIpNr�ittiRi '. N-' �9 - y� ® 'u•r.tt+ulNaa uae a�a x'^ �°'tiY■�'� NY®I� 'k8p�l 0.�"f�'N17NIdlV°N ,',y`dg,'#�n.' e ° a o w o l�sNN — - �- __ ._.. r of ti '. i4rtt .,mu'sfi µu".i tartxs Km.. a � , � !I IPDe�IE�ln. ® � ' �, ��Ri� IIR@Iry � HOW � �I :/iY" �� � I � son,I � 1Oi.. I �...i � !� : - I ilii '�� d ■■00101 , � 31 I II!I ;II yg� a [� gg .mmY•i. i tlevel' ' l ; f � � �I w Not I� 1110 Man, I SI I ',y - I , I N■ f II I:A iI'"I$at t : VIII i. 11 ep,N� 1531 til ■� 1 'II� q _ I 9'�'±� � lt �!- I��iII ■Olfl "'nn' .RMr�'mw/uv' III ,wool am w'r. i d �■i _ I min � i .: rt . a N`T 13 mm d d '.1 I I � a �g1 I i ins""� I, I� ....,.�.,.I..xM.,.., ..,a '-f'��NII i ' � N �NIDAF11 ID,6t R ' 'I i ■N'I ' , IN f"41 c, ID111 ■ �NNIfiu, ■ 1. n j n•'in IDN'1■■11 ,10 tl° NihX . & r,,y■'11 ■ N S �, , If:■161, i I %i IDN IMP, m- .'rm'� �.ia. 'e:',al•� x' �.i 'N" I! 'k'- n. � ' j i I - ' 4 I . '�, � i, ; . � ''$1 ■116n u»la nrpp m:npm• p W»O i+ca.i rn a mp p'rmYl 1 I �19I149 Wd'iIi'ffi'N 6� � j " I , . ,I, i':gqi'eq■I■ ■'1 �u. ■11 : q :r � j{ ;N■ 0 i .IR 'lib■11 ID1.■ ■■N ■ i'� j1 ■I ■ ■ 11ID II 'lN'■ '3.q!■ #'.'k�..� , ININ:N fi�I .3 j, u� aN�, ``-!'.; I �{ � ; it @� a n■ 1N;NIN■■ liID� ■ 1, , ID ■ 117�1ID■ + ., : : 1 yNp ,I �Ii II'1 N■ q Y rel" 11■IID ■13F.N'N IDi■g6ae 6 A. ' Y± ,I rl - : .. ,..t 6&1'0 501 .I I,�, �1 YiNNN� .:a; �, . i ,. m':' "6■ �■ I' y. II■ 'NNIDN■NI NigI NIN ■!1001 �'illl �eS,NIN GA r6'■ !B'�S�Ni1R'NIdP 3°. I_� I -I ' .. 3 r,:.. R� �., .i n, ,.�., �.:l�a� � I_ I IDf �NN11'166 N'■ ■■1■®II4'� I'... ti,..; 'IFtI �6,ID '�' 16 � 4&I.w:°,IIDI:• a'i ■� 1.■I W . rW 'NN�mI _ � .1� �� I __ :_ 1 �rl j._I_� III��IIIE ■ ■ N ra 1.1 N 111 �I■■ I ■Il NIS!■i ■I�'i r�1ID■ll■ le�I 1■1r.1 ID IDlil ,111 e�:Nl��:� r� t..,x:l�l�;�3'I�t . _ ., .,. . 9.. J_:._i_ I � I I �qm■■��qjN ■ 1�� :-I_-- - -'- -�-�-I--�-- -I�_h�_�_I_. . � - - -I ° _ . .V �■��I■� 11NIm�■��s�ar�. ( � j ....�_':__rte:—' '�� .._�-- - •,-__' ':-�--=-�� ----------- --=-=---- --- ------ --------------- — rariwrrwYr rrwr r ............rte r.u/wR.rini•iwR R'�`%�n�Moiw.innoi%iri/uiu''” _ "" MINIMUM.- .nr wimec"•ipi:'m�n r s�niM�osir"a_a ...%r L.....::Rod'Ow'1'� == rrrrrMrMrw r ooiewo a ____ SRYMMrMrr rR��•Iu1QwrM1Y Nm;R�pr.'•IR rrw r.=niR iriRYrrnimr rrrwrM rMrYrr �nMwYrwn,Mn;a:riiarmrmrw r - --- --_—__ _ _ ;�amTiRr Mr Mrrw�MMMPYprr.WM,' 'Yr rri �• w rs M �O mi..nrf.•.vi wS• MM,M pYr rA� Y mrrmwllRgl.mrr'TYrMiir Yr SpwMMYIiIRr/nrrry �fi �Rir•asrn.a'nvmaorYrp7r �ip rpp R. MrrYMrY _ imWf .j Rr n.lnl Yf® Mr SrrrY »RMMmm p1 rwr Y MYOMMRl..r YYMrrrlmr� r.T mYmiwR:imr rY rNMi�Mr`m�Rlala aysOSo.Oilwi�l�YYMi: - .imRi��/•f m•D'R/Iw �iYml%YW:mi ptuY MRlrplrrm �i�fu. Y,pmnrl.MON. r����yj���y�r��•����Yr�.r �a •• r i. M..i vrrrrrriW YremY`Y�R �a Yw_aruamenmr�prr_Y_ rar�rrrYlRrew:fm.u.ri m.nlm °�r�Y.or www�,i»+Ie.aM+cW _____ _ _ 3N Y M,mmprar_a _ rnY! r nRmmmiOprrMR..=—wiru� ��Ni",h� urinaiwrm.:./miw.Y.i xYrv�w��iu�.["wnuu/i�maaanY'a�'�wow� mf.rv"e.s.wrsra ~m,x.,;Mi�,:Mm,Yµv:. m'RuuY. .mffl�A ua.aem4 FKn;.�.UFimnsrwOWa�r�mmN•H,if�irme'q n:O_Nrrra rMm �•»® p�iYMmwnnnanami,.rri�� �auicu®a n�ie�rar:�RS • I��iE 'v�Y9lA•SN¢n�.ie�^'�—�!'•-�rP•�m�iw��r' ------------- 51 m Y Y n • a 0 n i . V . ! Y n �.��'� q� �Iq T"•3 m r t • e s = e � _U K W O O ~ v — lZ } 4 � Z — ZZ 1 w d y UWP u y - \`` \: All uj _ 0 LU LU ❑� - z � z W L I El W Ll - - - --- z ® FIT O Q El E Lu I- Q �T Tu u u U --�- u u u - " - u u u - u u u - - LLJ 0 'I I .y SIIQ - � 'I z II�III � 'I� h R I i Cr Q _-- w n LL flw lu MIMI > 'I L z w , y y: EAST ELEVATION is �l w o F11 riAME I ER SFI FV cuR os o u� ��yyeonn. r�.rve„pgrj Sr.ALE N `@ q�44x � [ANG NAME PROPOSED a' 021 �© 5 EAST dD�e panELEVATION ".v""OP'1°fNSi� =A4 IM -�BUHraA'I Iua ,S. II lS i w il-J 1j1 A �NIA' I- HF splr ricoYFH„ �iF I W AHCHHH.I NU H6✓IS1Oi,S GFi,_NGLG, ANl] 0�9 L1CGIHCtIiul F �NH SHAI I H ..[ I UJ 1A I1 HUU[ %HI I II I AI j I HOHI:P ii( r) B" IHC AHCHI I LC I AN) HLHH(1UUC ICM IN PAH IN ,YHCILL I::-,TIO IL, I HOHIBIII „ H) L.., CONSTRUCTION LEGEND : INSULATION NOTES : WINDOW LEGEND : _GENERAL NOTES : _ — — — — _ _ ELECTRICAL LEGEND : � eW _ 1. ALL WORK SHALL COMPLY WITH FEDERAL, STATE, AND LOCAL BUILDING CODES EXISTING EXTERIOR PARTITION TO REMAIN PROV. 1/2" GWP. BD. & R-15 HIGH EXISTING EXTERIOR WALLS: 2"X4" WOOD STUD. R-15 HIGH DENSITY INSULATION NOTE: ALL INTERIOR CASING TO BE STANDARD COLONIAL CASING CLEAR PINE DENSITY INSULATION TO ALL EXISTING EXTERIOR WALLS. BY'CERTANTIEED' OR APPROVAL EQUAL. UNLESS OTHERWISE NOTED. NOTE ALL ELECTRICAL WORK TO BE IN ACCORDANCE WITH THE RULES AND r�JT�,( > > L AND ORDINANCES. REGULATIONS OF THEN Y.B.F U. AND A CERTIFICATE FROM THE N.Y.B F U, IS TO ^ I a _ NOTE ALL WINDOWS TO BE MARVIN WITH STANDARD MARVIN HARDWARE. BE PRESENTED TO THE OWNER AT THE COMPLETION OF THE JOB, e v] k 2. EXISTING INTERIOR PARTITION TO REMAIN, PROV 1 LAYER 1/2" GYP. BD BY'CERTAINTEED' OR APPROVED EQUAL. ALLOW FOR EXTENSION JAMBS FOR AN 8" CONIC. BLOCK WALL. F� Z O BEFORE COMMENCEMENT C WORK, THE CONTRACTORS SHALL FURNISH THE BOTH SIDES OF EXISTING WOOD STUDS CLR PINE 4" COLONIAL BASE TRIM. COLOR TO BE WHITE. PROV. SCREENS FOR ALL WINDOWS. NOTE: THE OWNER SHALL PROVIDE ALL LIGHTING FIXTURES UNLESS OTHERWISE 'z OWNER AND ARCHITECT WITH COPIES OF ALL REQUIRED INSURANCE AND NOTED. ALL OTHER ELECTRICAL EQUIPMENT AND MAT'L. TO BE SUPPLIED BY THE WORKER'S COMPENSATION CERTIFICATES AND NAMES OF ALL SUBCONTRACTORS NEW ROOF: R-30 KRAIT-FA INSULATION BY'CERTAINTEED' OR APPROVED EQ,NEW EXTERIOR PARTITION- 2"X 4"WOOD STUD WALL W/ 1/2" COX PLYWD. ELECTRICAL CONTRACTOR, FOR ALL DIMENSIONS AND a - 3. THE CONTRACTORS SHALL BE RESPONSIBLE "-,- EXTERIOR SHEATHING (TWEK WRAPPED &TAPED), 6" EXPOSURE PERF. WD. CRAWL SPACE R-19 KRAFT-FA INSULATION WITH PROPER WIRE TIES OCAWN 2432 ©CAWN 2428 © CCM 2836 (EGRESS) NOTE: ALL SWITCHES AND RECEPTACLES TO BE'LUTRON', "DECORA" IN COLOR CONDITIONS ON THE JOB. THE ARCHITECT MUST BE NOTIFIED OF ANY VARIATIONS SHINGLES (PROV. 1 COAT BLEACHING OIL), 1/2"GYP. BD.(SCREWED /TAPED) INSTALLED AS PER N.Y.S. BUILDING CODE. O NOWNLIGHT TRIMS TO BE WHITE .O D FROM THE DIMENSIONS SHOWN. CUR. PINE 4" COLONIAL BASE TRIM, & R-19 FOIL FACE INSIUL. (HIGH DENSITY). OCCM 2840 (EGRESS) EO CUDH 2422(EGRESS) FO OUCH 2424 (EGRESS) NEW BASEMENT. R-10 RIGID FOAM 20" BELOW GRADE AROUND ENTIRE 4, THE CONTRACTOR SHALL SUPPLY ALL LABOR AND MATERIAL SHOWN ON THE NEW INTERIOR PARTITION- 2" X 4" WOOD STUD WALL WITH 1/2" GYP. BD. BASEMENT PERIMITER. ©CUDH 2620 OH OUCH 2624 JO CUDH 2626 (D DUPLEX ELECTRICAL RECEPTACLE @ O O DRAWINGS UNLESS OTHERWISE NOTED. !i;�<<, RESIST ED/TAP. ( APPLIED BOTH SIDES. NOTE, PROVIDE MOISTURE OK CUDH 3224 ©CUDH 3228 OM OUCH 3616 $GFI DUPLEX RECEPLTACLE/GROUND FAULT INTERRUPT RESIST GYP. BD. (GREEN BD.) FOR ALL BATHROOM WALL AND CEILINGS BASEMENT CEILING R-19 BUILDING INSULATION WITH PROPER WIRE TIES y 7 N 5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ADEQUATELY BRACING AND PROV, CEMENT WALL BD. FOR ALL TILE AREAS, INSTALLED AS PER N.Y S BUILDING CODE ON CUDHP 6062 OO CUDHP 6854 ©CUDHP 6858 $SC DUPLEX SEPARATE CIRCUIT RECEPTACLE PROTECTING ALL WORK DURING CONSTRUCTION AGAINST DAMAGE, BREAKAGE, COLLAPSE, DISTORTION, AND MISALIGNMENT ACCORDING TO ALL APPLICABLE INTERIOR PAINT- TO BE "BENJAMIN MOORE" U O.N. ONE COAT PRIMER AND ® -,CCMP 4060 ®EXISTING WINDOW WALL SWITCH ?< � CODES TWO COATS FINISH (COLORS T B.D BY OWNER) SATIN FIN. THROUGHOUT a� U O N. ALL TRIM SEMI-GLOSS. $a 3-WAY WALL SWITCH 6, THE CONTRACTOR SHALL PAY FOR AL PERMITS, FEES, AND COSTS RELATED TO g 4-WAY WALL SWITCH 5-WAY WALL SWITCH ^ 4 ! THE WORK OF THIS CONTRACT. CONTRACTORS SHALL INITIATE ALL REQUIRED DOOR LEGEND : ti m INSPECTIONS OF ALL WORK COMPLETED UNDER THIS CONTRACT `Vde CEILING MOUNTED JUNCTION BOX U �a I 7. THE CONTRACTOR SHALL AT ALL TIMES KEEP THE PREMISES CLEAN AND IS 0Ja WALL MOUNTED JUNCTION BOX P4 - RESPONSIBLE FOR REMOVAL OF ALL RUBBISH FOR ALL TRADES FROM THE JOB SITE Q L NOTE ALL INTERIOR CASING TO BE STANDARD COLONIAL CASING CLEAR PINE 14 8. ANY"EXTRAS" FOR ALL OR LEGITIMATE UNFORESEEN CONDITIONS SHALL BE UNLESS OTHERWISE NOTED. PROV SCREEN DOOR UNITS FOR ALL EXT. DOORS DOCUMENTED WITH THE COST OF APPROVAL BY OWNER OR HIS AGENT PRIOR TO RECESSED DOWNLIGHT (100w) "LIGHTOILER"OR APPROVED EQUAL LII STARTING ADDITIONAL WORK. Ex EXISTING DOOR TO BE REPAIRED & RE-USED. R EXTERIOR MOUNTED DOWNLIGHT (100 W) E' oN 9. DOUBLE JOISTS ARE TO BE INSTALLED UNDER ALL WALL PARTITIONS RUNNING 7� ~� a (� '. PARALLEL TO THE FRAMING. PROVIDE DOUBLE HEADER JOISTS AT ALL OPENINGS. EXTERIOR DOOR- 3'6"X 6'8" SOLID PINE DOOR WITH RAISED PANELING. PROV. de WALL MOUNTED DUAL SPOT LIGHT �KnOm REFER TO CONSTRUCT DRAWINGS FOR SIZES. O SOLID BRASS HINGES & SCHLAGE HARDWARE. NEW CEILING MOUNTED JUNCTION BOX FOR RECESSED EXHAUST \' � i; EXTERIOR DOOR- 5'3"X 6'8" SINGLE FRENCH DOOR AND SIDELIGHTS WITH RAISED EF OR APIP EQUAL, GHT WITH DUAL SWITCH AT WALL. GROAN" HEAVY DUN UNIT !I L` 10 ALL FRAMING LUMBER TO BE DOUGLAS FIR #2 CONS. GRADE OR BETTER. O PANELING. PROV. SOLID BRASS HINGES &SCHLAGE HARDWARE. ��y��� 1 IS 11 THE CONTRACTOR SHALL PROVIDE SHOP DRAWINGS FOR ALL SPECIAL WORK EXTERIOR DOORS- 3'2"X 6'8" SOLID PINE DOOR WITH RAISED PANELING EXT MOUNTED LIGHT WITH FAN F X 1 s SUCH AS BUT NOT LIMITED TO. MILLWORK, SPRINKLER SYSTEMS AND STEEL WORK. 3 �Q � '�i O PROV. SOLID BRASS HINGES & SCHLAGE HARDWARE. •sD SMOKE DETECTOR/CARBON MONOXIDE DETECTOR: TO BE SWAN, II ALL SHOP DRAWINGS NEED THE APPROVAL OF THE ARCHITECT BEFORE \ PROCEEDING 4 EXTERIOR DOOR- 2'8" X 6'8" STATIONARY FRENCH DOOR WITH RAISED PANELING. HARD WIRED TO CENTRAL CONTROL BOX I ° ���`""" ' L O PROV SOLID BRASS HINGES &SCHLAGE HARDWARE Q T NEW TELEPHONE RECEPTACLE � I ���� ISI O5 EXTERIOR DOORS-5'4"X 6'8" PAIR FRENCH DOOR WITH RAISED PANELING. Q G CABLE TV RECEPTACLE `u3GM`, �'na PROV SOLID BRASS HINGES &SCHLAGE HARDWARE EXTERIOR DOORS— 33"X 61811 SOLID DOOR WITH RAISED PANELING BATHROOM VACUUM OUTLET (PROVIDE NECESSARY ELEC POWER) PROV. OLID BRASS HINGES & SCHAGE HARDWARE.FLOORING LEGEND : EXTERIOR DOORS- 4'0" X 6'8" PAIR FRENCH DOOR WITH RAIISED PANELING (EXISTING) U O PROV. SOLID BRASS HINGES & SCHLAGE HARDWARE. 7 ryry HARDWOOD FLOORING-SELECT WHITE OAK 2 1/4" Z W., 15LB FELT., \J (3 FINISH COATS OF OIL BASED SATIN POLYURETHANE. e EXTERIOR DOORS-2'B" X 6'8" SOLID PINE DOORS WITH RAISiED PANELING.O ' I I }"PROV. SOLID BRASS HINGES &SCHLAGE HARDWARE. Lu SUB-FLOOR-USE 3/4"THICK PLYWOOD GLUED AND NAILED. Q ?' SUB FOR TILE AREAS TO BE SCREWED AND GLUED. O EXTERIOR DOORS- 3'6" X 6 " SOLID PINE DOORS WITH RAISiED PANELING. '8 LI PROV. SOLID BRASS HINGES & SCHLAGE HARDWARE ® EXISTING WOOD FLOOR TO BE SANDED & REFINISHED W/2 COATS SATIN 1 O INTERIOR DOORS- X GE SOLID PINE DOORS WITH RAISIED PANELING 1"I'' L PROV SOLID BRASSS HINGES & SCHLAGE HARDWARE W REF POLY. (NPALL AREAS) PATCH ALL AREAS ASREQUIRED) BEDROOM 11 INTERIOR DOORS- 2'4"X 6'8" SOLID PINE DOOR WITH RAISED PANELING. 12'0" X 18'0" CERAMIC TILE - "AMERICAN OLEAN"TILE OR APP. EQ. TILE TO BE INSTALLED PROV. SOLID BRASS HINGES &SCHLAGE HARDWARE. (EXISTING) ® OVER 1/2" CEMENT BOARD U.O.N. WALL AND FLOOR GROUT TO HAVE INTERIOR DOORS- 2'6"X 6'8" SOLID PINE DOOR WITH RAISED PANELING Q WATERPROOF ADDITIVE MIXED IN 12 PROV. SOLID BRASS HINGES & SCHLAGE HARDWARE rm('r�� INTER OORS— 21811 X US' SOLID PINE t3 PROV. OIORDD BRASS HINGES &SCHLAG HA DWARE,RAISIED PANELING. Q E F F F F F PLUMBING LEGEND : 14 PROV INTERIOR SOLID BRASS HINGESDOOR— 31011 X 61811OLID&SCHLAGEPINE DOHOARRDWIARE TH AISE'D PANELING. III INTERIOR DOORS- 2'4" X 6 " SOLID PINE POCKET DOOR WITH RAISED PANELING. d e ,46„ P P •P PROVIDE ALL NECESSARY PLUMBING ROUGHING AND VENTING AS INDICATED 15 '8PROV. SOLID BRASS HINGES &SCHLAGE HARDWARE _ _ LL BU CONSTRUCTION PLANS). FOLLOW ALL NECESSARY N.V.C. AND N.Y.S. D iso ROV!OSOLDID BRASS H X 6'8' PAIR SOLID PINE DOORS WITH RAISED PANELING. BUILDING CODES THAT APPLY TO WORK BEING COMPLETED PROV ALL 16 - NECESSARY DRAIN VALVES HINGES & SCHLAGE HARDWARE. I 0 - � � BATHROOM O •F PROV FLOOR DRAIN AND 10. GAL. SUMP. _\10'6" X 13'8" — - — 2q � � YJo' , —(EXISTING) 7 ON FVVM ORB PROVIDE FROST FREE HOSE BIBS. J I DN REF. 11 — 6„ J P — • R - —_CFI _ - K — - K S SHOWER HEAD / _ P Q ' GFI P P c r NIS X I ® *SD 1 / — / — / EF T I I VLYYI _ _ -.—L__ -_ Lu HEATING/AC e � )UP FV917 K EGREBS MT FLOOR REGISTER (7" SUPLY DUCT) / - I REF. I I . REF mm DUCTWORK IN FLOOR BELOW (ROUTING SUBJECT OT CHANGE) /I I / -JR I / W � ® SUPPLY REGISTER (CEILING) 1117— 1 H H IIB K 0 T RETURN REGISTER (CEILING) -�' - 1- vF- L Z ^ RETURN REGISTER (WALL) 1 14 7 c LL KITCHEN EXHAUST REGISTER (CEILING) I< I` - 14 \ -\\ O JB02/; u a D 14 /II/Oyy W ^ L - D REF. j BATHROOM — �— - - - - - - - D a D T F — .� E 1'-6' 15'0" X 20'0" (ExIsrlNa) __ - - •BD I �- • _ — I " T I Jp _ ¢ a L _ e 1:S atj II FF' P GR _— K K —K-EGFiEuBEDROOM 0. (9 FI � — _ — _ _ / I - 15'6" X 1s'1 O" w o u —� / D I— p _ (EXISTING) J J J REF. REF — -63 / c 6,_O„ - _ - - 0 o T. •SID f (0 P �F -- _ _ - _ - _ _—- _ -le" le" G D U (hw ] O N ur 917ju IIN _ A C 0 U K K K K FILE NAME: F — J E _2_ _ 2CP R 7l .1�VI�I(I III 28 OF SCALE o emu II Idi: „ e1 1/4"=_ IUIII 41411 DWG. NAME: o �r� SECOND FL. PLAN DWG. NO. BEDROOM/ BEDROOM BATHROOM THESE DRAWINGS AS INSTRUMENTS OF SERVICE, SECOND FLOOR PLAN ARETHE SOLE PROPERTY OFTHE ARCHITECT 16'X" X 18'0" 13'6" TI 1$'O" (EXISTING) X 8'6" NO REVISIONS,CHANGES,AND/OR MODIFICATIONS (EXISTING) - _ (EXISTING) (EXISTING) SHALL BE ALLOWED WITHOUT WRITTEN AUTHORIZATION TOTAL SO.FT. = 2,324 ORWHOALEIISSlS1RICTLYPROHIIBITDEDCBYOLAW PART A. GENERAL NOTES : 1 ALL WORK SHALL COMPLY WITH FEDERAL, STATE, AND LOCAL BUILDING CODES 'S AND ORDINANCES. y 2. BEFORE COMMENCEMENT OF WORK, THE CONTRACTORS SHALL FURNISH THE OWNER AND ARCHITECT WITH COPIES OF ALL REQUIRED INSURANCE AND WORKER'S COMPENSATION CERTIFICATES AND NAMES OF ALL SUBCONTRACTORS. T, � yU N 3. THE CONTRACTORS SHALL BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB THE ARCHITECT MUST BE NOTIFIED OF ANY VARIATIONS ` 4 FROM THE DIMENSIONS SHOWN. -- 4 THE CONTRACTOR SHALL SUPPLY ALL LABOR AND MATERIAL SHOWN ON THE O "I DRAWINGS UNLESS OTHERWISE NOTED. 5 THE CONTRACTOR SHALL BE RESPONSIBLE FOR ADEQUATELY BRACING AND i `7 mN PROTECTING ALL WORK DURING CONSTRUCTION AGAINST DAMAGE, BREAKAGE, COLLAPSE, DISTORTION, AND MISALIGNMENT ACCORDING TO ALL APPLICABLE 7 Z a CODES 6. THE CONTRACTOR SHALL PAY FOR AL PERMITS, FEES, AND COSTS RELATED TO THE WORK OF THIS CONTRACT. CONTRACTORS SHALL INITIATE ALL REQUIRED INSPECTIONS OF ALL WORK COMPLETED UNDER THIS CONTRACT 5 d e 7 0 7 THE CONTRACTOR SHALL AT ALL TIMES KEEP THE PREMISES CLEAN AND IS RESPONSIBLE FOR REMOVAL OF ALL RUBBISH FOR ALL TRADES FROM THE JOB SITE. J 3 � 8. ANY"EXTRAS" FOR ALL OR LEGITIMATE UNFORESEEN CONDITIONS SHALL BE DOCUMENTED WITH THE COST OF APPROVAL BY OWNER OR HIS AGENT PRIOR TO STARTING ADDITIONAL WORK k � - 9 DOUBLE JOISTS ARE TO BE INSTALLED UNDER ALL WALL PARTITIONS RUNNING PARALLEL TO THE FRAMING PROVIDE DOUBLE HEADER JOISTS AT ALL OPENINGS r REFER TO CONSTRUCT DRAWINGS FOR SIZES. _ 10. ALL FRAMING LUMBER TO BE DOUGLAS FIR #2 CONS.. GRADE OR BETTER. 5 �' SEE�` 11 THE CONTRACTOR SHALL PROVIDE SHOP DRAWINGS FOR ALL SPECIAL WORK SUCH AS BUT NOT LIMITED TO MILLWORK, SPRINKLER SYSTEMS AND STEEL WORK. � � ALL SHOP DRAWINGS NEED THE APPROVAL OF THE ARCHITECT BEFORE Is � £ PROCEEDING. LLI WINDOW LEGEND : U NOTE, ALL INTERIOR CASING TO BE STANDARD COLONIAL CASING CLEAR PINE \ Z. O UNLESS OTHERWISE NOTED NOTE ALL WINDOWS TO BE MARVIN WITH STANDARD MARVIN HARDWARE. L{ C5 ALLOW FOR EXTENSION JAMBS FOR AN e" CONIC BLOCK WALL COLOR TO BE WHITE. PROV. SCREENS FOR ALL WINDOWS. 10UI -ZI I AO CAWN 2432 BD CAWN 2428 ©CCM 2836 (EGRESS) LL E E E E O CCM 2840 (EGRESS) EO CUDH 2422 (EGRESS) FO CUDH 2424 (EGRESS) Q ©CUDH 2620 OH CUDH 2624 JO CUDH 2626 K LL OK CUDH 3224 ©CUDH 3228 OM CUDH 3616 ON CUDHP 6062 OO CUDHP 6854 (5CUDHP 6858 TEMPORARY LL -- DEC © Lu CCMP X4060 ®EXISTING WINDOW STAIR. K-BELOW,W- `u - - DE-SV�BE-LLL LL ATTIC C SUBJECT TO ZONING Z C _ I— ATTIC DN SUBJECT W E ATTIC ATTIC / ATTIC TO ZONING - D J SUBJECT \SUBJ'_CT SUBJECT i( TO ZONING TO ZONING TO ZONING �l Lu c> / 0 ATTIC — — — — — � o. SUBJECT/ <I; D TO ZONING r - - - - - - - - - - - - - - - - —� — a Ori) w a IJ.1 E _ — ATTIC SUBJECT TOZONING ATTIC Is o _ - SUBJECT / \ ATTIC TO ZONING ATTIC SUBJECT - - - 0 i i W SU— TO ZONINGECOND-F-L - - _ SII ❑ - - — TO ZONING --- DECK-SE-LOWI ~ Z !1 ❑ © DH 1612 U 'r ] D CUDH 1620 _ _ SECOND FLOOR ❑ I ❑ W I I W 7 .r 7 DECK BELOW. N i i uCi O Il N W O Ir O p oM o nf o FILE NAME : lk E EEG FER_3CPA"iTIC_CUR o 03/01 022 SCALE �R"LLML '4^dby r +'yJ "f;A DWG NAME. EXISTING I� ATTIC PLAN LAN ATTIC AREA DWG. NO. SUBJECT TO ZONING THESE DRAWINGS OF SERVICE, ARE THEESOLE OLE PRGS AAS SINSTRUMENTS THE ARCHITECT OO NO REVISIONS, CHANGES.AND/OR MODIFICATIONS TOTAL SOFT. = 1 ,830 SHALL BE ALLOWED WITHOUT WRITTEN AUTHORIZATION A.ATTIC BY THE ARCHITECT, ANY REPRODUCTION IN PART OR WHOLE IS STRICTLY PROHIBITED BY LAW SPRINKLER NOTES: 1. ALL NOTES BELOW PERTAIN TO NFPA 13D 1991 EDITION UNLESS OTHERWISE NOTED. 2. THIS SPRINKLER SYSTEM IS HYDRAULICALLY BALANCED AS PER ACCOMPANYING CALCULATIONS AND SECTION 6-4. DESIGN CRITERIA ' 3. THE INSTALLATION, COMPONENTS, SIZING, SPACING, LOCATION, POSITION AND TYPE OF SYSTEM SHALL CONFORM TO CHAPTERS 3,4,AND 5. BE LISTED OCCUPANCY CLASS RESIDENTIAL-LT.HAZARD OF NFPA 131991 EDITION, ALL EQUIPMENT SHALL 4. AS PER CHAPTER 3 AREA OF APPLICATION 450 SF OR APPROVED FOR FIRE PROTECTION SERVICE. _ / / / / / / n� / / COVERAGE PER i 5. SPRINKLERS ARE TO BE PROTECTED AGAINST FREEZING AND INJURY AS PER SECTION SPRINKLER HEAD 225 SF 4-5.4.1. PROPERTY OWNER IS TO MAINTAIN A MINIMUM OF 400. IN ALL AREAS OF WET PIPING. WOOD BEAM 6. INSPECTION AND TEST OF SPRINKLERS SYSTEM SHALL BE CONDUCTED AS SPECIFIED IN OR JOIST NCALCULATED O. OF SPRINKLERS 1 &2 I CHAPTER& THREADED SYSTEM DEMAND 7. THE OCCUPANCY OF THE AREAS TO BE SPRINKLED SHALL BE IN ACCORDANCE WITH 31.49 GPM �41.49 psi SECTION 1-4-7, AND AS SPECIFIED ON PLANS. �- SCREW ROD cGfl NODE 8. WATER SUPPLY TEST PIPES AND GAUGES SHALL BE PROVIDED AS SPECIFIED IN SECTION "K"FACTOR 5.6 K 4-6.4.2. 9. PIPING SPECIFICATIONS, SYSTEM TEST PIPES, PROTECTION AGAINST CORROSION, ' DRAINAGE, FITTINGS,VALVES, HANGERS, GUARDS AND SHIELDS SHALL BE IN ACCORDANCE WITH NFPA 13. SWIVEL LOOP 10. STOCK OF EXTRA SPRINKLER HEAD WILL BE FURNISHED AS SECTION 2-2.7.(REQUIRED HANGER L E G E N D FOR EACH TEMPERATURE RATING). 11. SPACING, LOCATION AND POSITION OF SPRINKLER HEADS WILL BE ACCORDANCE WITH INDICATES NEW PENDANT SPRINKLER HEAD TO BE QTY. CHAPTER 4. 0 RELIABLE MODEL F4/RES. ORIFICE-1/2"K FACTOR-135°F. 98 CONTRACTOR: 12. 1"TO 12" MINIMUM CLEARANCE OF SPRINKLER DEFLECTOR TO CEILING AS PER SECTION 4-4.1,4.1. TYPICAL HANGER INDICATES NEW SPRINKLER PIPING LINE GLOBAL FIRE SOLUTIONS, INC. 13. DISTANCE OF SPRINKLER FROM HEAT SOURCES SHALL BE IN ACCORDANCE WITH TABLE H.T. 47 BROADWAY 4-3.1.3.2 A&B. INDICATES TYPICAL HANGER LOCATION EVERY 10'-0"O.C. &WITHIN 18"OF EVERY HEAD LYNBROOK, NY 11563 14. DRAINAGE TO CONFORM TO SECTION 4-6.3, 15. ALL VALVES SHALL BE IDENTIFIED AS REQUIRED BY SECTION 2-7.3. O FAX.: (516) 872-8463 16. ALL VALVE CONNECTIONS TO WATER SUPPLIES AND IN THE SUPPLY TO SPRINKLERS SHALL g HYDRALIC REFERENCE POINT �+ BE APPROVED O.S.&Y. OR APPROVED INDICATOR TYPE AS PER SECTION 2-7.1.1. PUBLIC L I C�# 11 3595988 17. DRAIN VALVES AND TEST VALVES SHALL BE APPROVED TYPE AS PER SECTION 2-7.2. WATER 18. HANGERS SHALL BE OF A TYPE APPROVED FOR USE WITH PIPE OR TUBE INVOLVED MAIN IN ACCORDANCE WITH SECTION 2-6. 19. PROVISIONS SHOULD BE MADE TO FACILITATE FLUSHING SYSTEM PIPING BY PROVIDING Q FLUSHING CONNECTION CONSISTING OF A CAPPED NIPPLE 4"LONG ON THE END OF THE CROSS MAIN AS PER SECTION 4A.1.7.18. 20. SPRINKLER HEADS SHALL BE AN APPROVED TYPE AS PER SECTION 4.3. 21. TEMPERATURE RATINGS SHALL COMPLY WITH SECTION 4-3.1.3. 22. 18"MINIMUM CLEARANCE TO BELOW SPRINKLER DEFLECTOR AS PER SECTION 4-4.1.6. _ 23. UNDERGROUND PIPING IS TO BE SUPPORTED WITH RODDING, BLOCKING AND CLAMPING AS PER NFPA 24(1992 EDITION)REQUIREMENTS. � I � 1--�� 24. CURB BOX VALVE IS TO BE PROVIDED AS PER NFPA 24(1992 EDITION). - - 25. INTERCONNECTION OF ALARM DEVICES TO BUILDING FIRE ALARM SYSTEM SHALL BE BY OTHERS. _ _ 26. ALL REQUIRED SINAGE SHALL BE PROVIDED IN ACCORDANCE WITH NFPA. 27. ALL PIPES TO BE AS FOLLOWS: MAINS 2-1/2"&LARGER TO BE BLACK STEEL SCHEDULE 10. r 1 BRANCHES 2"&SMALLER TO BE BLACK STEEL SCHEDULE 40. /\ 28. ALL FITTINGS TO BE AS FOLLOWS: MAINS 2-1/2"&LARGER TO BE GROOVED TYPE FITTING. - BRANCHES T&SMALLER TO BE Cl THREADED. N \ \\ 29. "CONTRACTOR'S MATERIAL AND TEST CERTIFICATES FOR ABOVE GROUND AND(WHERE � APPLICABLE)UNDER GROUND PIPE"SHALL BE SUBMITTED TO THE FIRE MARSHAL PRIOR TO APPROVAL OF THE INSTALLATION. _ I \ \\ � I - - - - - - - - - - - - - - - - " 1110 "0 M0 COPPER - - -211 be JB SEE RISER ,,, B DIAGRAM b Z - - - - - - - - - - - - - - - - - - - - - - I--- - - - - - - - - - - - - - - - - - - = - - - - - - - - - - - - - - - - - {- -I- - - - - - - F _ - - - - - - - - REV 1"0 1 / 1 '_ ,- " � REV DATE: 11 -2 /2'-10" 8 9 3'-3 3'-T' S'i11" 4'-5" 5'-9" PROJECT: � BASEMENT RISEIR UP TO 7 ANTIFREEZE - I T FLOOR is _ F_ ... FRS FERRARA RESIDENCE BASEMENT - Lo LOOP I �;GC RISER U To , I EAST MARION, NY III FIRST FLOOR �jB I'''�B *B 1„0,,, 1110 *B TITLE: �-")'1 �� # 6 BASEMENT PLAN �-- - - - - - - - b BASEMENT 1"0 1"0 I _ _ J r ' '` SCALE: PROJECT NO. 00 4F L x RISER UP TO 14'-7" 4'- L F.C.U.#3 THIRD FLO R oo i r 1 „� � AS NOTED 18 - 02 SUPERSTORE r r r r BOILER I B r M �B .n, �B �B � I- -I I- -m- -I �� ► ` �.�,�.., �rt-_ - ._ 4 DATE:7/12/02 DWN.BY: SG „ 1O " 1 o vo of "0 (� / 5,_0„ 91.01 - - - - - - - - - - - - - - - - Ali r - - - - 0 - - - - - - - - - - 7 - I I 1 1 I � 4 L __j I - - - - - - - - - - - - I It I I I I r1 I I I bo �j B = - - - -� ' EJB I I 1"0 1"0 vo 1„ID cl - / 8,- ' I I L . 38 L : � EBASEMENT I -I _I I -I „ \ �✓ r -� FRISERUPTO �.�r - - - - - - - - - - - - - - - - - - - - - FFIRST FLOOR ��pi10t�iT:ttfly�� N. _ - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - � p� ' I I o I I I I I I I I I II r l I � i ,`` a - - I - � r r - - - - - - - - - - - - _ = r - DRAWING NO: \ r 1 r BASEMENT PLANVk 1/4"=l NOTE: l .t 1.0 ALL SPRINKLER PIPING TO BE 1"0 CPVC PIPE APPROVED FOR RESIDENTIAL USE. CONTRACTOR: — _— - - GLOBAL FIRE SOLUTIONS, INC. 47 BROADWAY �.� LYNBROOK, NY 11563 PH. (516) 672-8466 FAX.: (516) 872-8463 LIC# 113595988 IF- III - - - - - - - � I -ll - -1, LTI -- JB� -- - I _ -_ - _ - - -- � .. IIID _ h III 1= — — ill= —L, - i I --III II — I�n I I I it i ' I I�� I m Fj 1"0 — 10 1"0 I"0 T"6I J�, 0 Jo 1'"0 i c 8'-2' 1'-a• _ 3'-2' _ Je 12" = I L-1 _ m N (� 0 - � a JB o P=- __ - Fn _ e 10 1"0 e h �A RISER FROM --- _ J 1"0 RISER FROM III BASEMENT � 4'_2" BASEMENT REV, DATE REV III NII I GATE V Vo r t+1 4'-2 I -- I II III PROJECT: — FERRARA ES ID NCE RISER FROM EASTMARION, NY BASEMENT TITLE: "m 1"0 FIRST FLOOR PLANI SCALE. PROJECT N0. AS NOTED 18 - 02 L - DATE.7/12/02 DWN.BY. SG — - CKD.BY: 1„0 1"0 — — m = - m m s'_z" e'-z' me - — I � M ' o - - - — - 1"0 1"0 - - - 1"0� 1"0 = - - - _ 3'-3'' 91-91, T� 3� B �_ _ 1TII111 RISER FROM - - I _I — ElBASEMENT ` n y _ E n - - - _ � / , '• Cys - n - - - _ - uWnunnur DRAWING NO. FIRST FLOOR PLAN SP - 2 NOTE 1 0 ALL SPRINKLER PIPING TO BE 1 '0 CPCV PIPE APPROVED FOR RESIDENTIAL USE i - II - I III II I 1� CONTRACTOR: GLOBAL FIRE SOLUTIONS, INC 47BROADWAY LYNBROOK, NY 11563 516) 872-8466 FAX.:((516) 872-8463 LIC# 113595988 1J LII � III� I III III I� JB OW ` I �1 1110 1"0 T_0" 3' Vo I IISD If Il I � o \ — m 19 n l9 r I I 1110 1"0 11"m JB REV. DATE' I 1 1110 REV I �e �� DATE — 4 _°„ JB PROJECT: B N IIII � � �� I I FERRARA RESIDENCE I �� EAST MARION, NY � � — �� m �� m m1"m vm �y 4'-T Vje iIIII II IIII I � � _ , - ,,, � 1 7/i _ 1 RISER FROM o J BASEMENT - m o m TITLE: SECOND FLOOR PLAN 2 5 _ 8 0 — I � � 1110 U'tp:)" - - - JB IL�J \ ,f� 1f�m – IIII 1110 s-2 SCALE: PROJECT NO. isoY m s s iso AS NOTED 18 - 02 LF DATE:7/12/02 DWN.BY: SG ® +J, ° ! CKD.BY: +je 0 �a 1 iL ° _ fff � *JB FF LL � III �_ ? 1m m �m „ r -- „\ — _ _ - nurmn.w,n )_l e { t \ glllllulllllAA11`1���� DRAWING NO: SECOND FLOOR PLAN S P 3 NOTE. 1,0 ALL SPRINKLER PIPING TO BE 1"9 CPCV PIPE APPROVED FOR RESIDENTIAL USE �I�Illlliljll - 11jljl 111111 ' llliillllililiii �ii ljlil l 1 -_ � IVIII � 111111111I I CONTRACTOR: AC TOR. GLOBAL — FIRE SOLUTIONS, INC — 4 7 - - - -- --- � 1r1111 __ . _ ( IIII ! J 11111111 111111111111111111111 BR OAD WAY -- - IIII 1 1111111111 111111 11111111111 LYNBROOK, NY 11563 -I PH. (516) 872-8466 _ FAX . (516) 872-8463 LIC# 11359598 - - 8 11111111 1 - X1111111111111111 IIII!III = -= IIII L - _T - -111 Illll l l I I S 11 ' 11 111111111 I- - 1111111j�llliliilll ' I� I 1�IIJI� 1 [��I11111 L1- _ ���1 I IIII 11�_I111 � I IF-�IPIII—�I1 L , I III I II 11 I I ' I� II 11� - SE COND F LOO R ELOV 1m1-4 — 11111I1111111111111111111I1111I11 ; IillIIIIl I - I 1 - �LIII ��ILLI!�11111 I 1 I -- - - Wok - so - 1 � 1 - - EF _ _ r _ - REV DATE REV DATE - — 1_ e„ — 111 II 111111 I I I -JB J¢ I -- Je -}EF — J6 - - - GFI -J¢ I� 1 1 �ISER I I_ PROJECT: 1••m III I I I I 1 � II I III III I I I FERRARA RESIDENCE s" EAST MARION, NY i m 41J J¢ 30 � ' ' 1� � Ila -� 10 ,111 = _ - r i. m m � 1 ' 111 0 1 1" 1, 21 Ila Ivo 1"0 1 0 1"0 1 111 111 g.. 4�A„ 2' 9' m , 6' 3�� B B ,� 6' 2 12 5'-10" 12 3'-0' c� h O L F C.0 — �1 TITLE: ¢ N — — i F - I -1 - _ I � r L THIRD 1�•m I IRD i rm FLOOR PLAN _.__._._._._._._._._. _.� 1111 1 r• 2'-2" I 111 11 I - I� 111 1 1111111 I I I E m 1. -L III m - - - _ - - - -I 11IIll Il� i m o Je -�- Je m o d¢ B m m m m �--_ ] - - 111 ' - _ io -m' Biu _ _ III 111111111 N m so SCALE: PROJECT NO. 10'-6' -- - - - - _ - - iso i 40 0 t flute - AS NOTED 18 - 02 IIII _ Irl I I J¢ rj¢ _ � — 1 1111 DATE:7/12/02 DWN.BY SG - _ L—'--'---'--' —_ - — CALCULATED - - _ - -- - REMOTE AREA - --- - -- L - - - - - - - - - _ - - - SECIINID FLOOR- _ - _ - - - _ l� — _ SEOOND FLOOR DECK BELOW._ -- - G��Cft..GL,\��`� r 41r4111IIIIIIIUAI"1�'�� DRAWING NO: THIRD FLOOR PLAN ^ -� NOTE 1 0 ALL SPRINKLER PIPING TO BE TO CPCV PIPE APPROVED FOR RESIDENTIAL USE FILL CUP 1110 ti T— if 1"OS&Y GATE VALVE LOCKED OPEN 1/2"TEST W-� VALVE Z N E � o G'Z Z¢ N tt0 LLO 00 CONTRACTOR: T 1/2'TEST GLOBAL FIRE SOLUTIONS, INC. I7 `VALVE 47 BROADWAY _ LYNBROOK, NY 11563 Jam - PH.. (516) 872-8466 1 1"SWING CHECK FAX.: (516) 872-8463 CLL DRILLED THROUGHH CLAPPER "HOLE PPER -DRAIN VALVE LIC# 113595988 NOTES 1)SOLUTION MUST BE COMPATIBLE WITH PIPING SYSTEM D+ DETAIL 1 NON-TOXIC ANTI-FREEZE sP-s LOOP DIAGRAM NTS IT I � i III I I III II III III - __ - IIII �I�I I IIS - - �� Ii I � 11 1°0 -- ��-- REV DATE. —-I — REV DATE PROJECT: _ I FERRARA RESIDENCE THIRD FLOOR - - - - - -- — —�kll EAST MARION, NY f ,I i �� �� ��� 11 ❑ ❑ I -IF ❑ TITLE: fid �I Hil Vol CROSS SECTION �I I I I� 'I �� I - _ � - hI I I � I - � ALE: �: I IIIA_ � - �- � -- - - -- I SC PROJECT NO. SECOND FLOOR - _ - - 18 - 02 - �� + _k , A AS NOTED u — - - � � -� �I 1 �I III "0 r'0 1"0 L� I — - : SII F ❑__II� �I I IIII II II � _ IN II Al FIRST FLOOR 4I - - __ - - — — - — — .. , - _ - 1" 1110 CPVC SPRINKLER lIPE PUBLIC 2 1 __ WATER 2 MAIN(BEYOND) 3 10 - 4 5 gannwneu,r„„ BASEMENT Ern - - - - - - E ^ - 2"0 COPPER of SPRINKLER MAIN SEE DETAIL FOR ANTI-FREEZE BYSTEM SPRINKLER RISER DIAGRAM CROSS SECTIONN.TS 1 WATER FLOW SWITCH DRAWING N0: PRESSURE GAUGE 3 1"CHECK VALVE NOTE' 10 ALL SPRINKLER PIPING TO BE 1"0 CPCV PIPE APPROVED FOR RESIDENTIAL USE. 4 1"CONTROL VALVE 5 SYSTEM DRAIN TO SAFE LOCATION SPa5 GENERAL CONSTRUCTION— -- - - -- -- - - - - - - tE ; - UCTION LEGEND : INSULATION NOTES :: DOOR LEGEND :: ELECTRICAL LEGEND : 1 ALL WORK SHALL COMPLY WITH FEDERAL, STATE, AND LOCAL BUILDING CODES = EXISTING EXTERIOR PARTITION TO REMAIN, PROV. 1/2 GYP. BD. & R-15 HIGH EXISTING EXTERIOR WALLS. 2 X4 WOOD STUD R-15 HIGH DENSITY INSULATION NOTE: ALL INTERIOR CASING TO BE STANDARD COLONIAL CASING CLEAR PINE NOTE. ALL ELECTRICAL WORK TO BE IN ACCORDANCE WITH THE RULES AND AND ORDINANCES, DENSITY INSULATION TO ALL EXISTING EXTERIOR WALLS. BY'CERTANTIEED OR APPROVAL EQUALUNLESS OTHERWISE NOTED. PROV. SCREEN DREGULATIONS THE N.Y. AND CERTIFICATE FROM THE N Y.e F.U. IS TO T DOOR UNITS FOR ALL EXT. DOORS. BE PRESENTED TO THE OWNER AT THE COMPLETION OF THE JOB. 2. BEFORE COMMENCEMENT OF WORK, THE CONTRACTORS SHALL FURNISH THE NEW EXTERIOR WALLS' 2"X6"WOOD STUD. R-19 FOIL FA. HIGH DENSITY INSULATION I Z O OWNER AND ARCHITECT WITH COPIES OF ALL REQUIRED INSURANCE AND = EXISTING INTERIOR PARTITION TO REMAIN. PROV, 1 LAYER 1/2" GYP. BDBY'CERTAINTEED' OR APPROVED EQUAL. Ex D . EXISTING DOOR TO BE STRIPPED, REPAIRE & RE-USED PROV. NEW HARDWARE. NOTE: THE OWNER SHALL PROVIDE ALL LIGHTING FIXTURES UNLESS OTHERWISE �I WORKER'S COMPENSATION CERTIFICATES AND NAMES OF ALL SUBCONTRACTORS BOTH SIDES OF EXISTING WOOD STUDS. CLR. PINE 4" COLONIAL BASE TRIM. NEW ROOF R-30 KRAFT-FA. INSULATION BY'CERTAINTEED' OR APPROVED Eq. NOTED. ALL OTHER ELECTRICAL EQUIPMENT AND MAT'L. TO BE SUPPLIED BY THE 'I :J CRAWL SPACE: R-19 KRAFT-FA. INSULATION WITH PROPER WIRE TIES INTERIOR DOOR- 2'6"X 6'8" SOLID PINE DOOR WITH RAISED PANELING. PROV. ELECTRICAL CONTRACTOR. 3. THE CONTRACTORS SHALL BE RESPONSIBLE FOR ALL DIMENSIONS AND NEW EXTERIOR PARTITION-2" X 4"WOOD STUD WALL W/ 1/2" CDX PLYWD. INSTALLED AS PER N.Y.S BUILDING CODE. NOTE: ALL SWITCHES AND RECEPTACLES TO BE 'LUTRON', DECORA" IN COLOR O SOLID BRASS HINGES & SCHLAGE HARDWARE. li 'yam' CONDITIONS ON THE JOB, THE ARCHITECT MUST BE NOTIFIED OF ANY VARIATIONS "„ ,7 EXTERIOR SHEATHING (TYVEK WRAPPED &TAPED), 6" EXPOSURE PERF WD NEW BASEMENT R-10 RIGID FOAM 2'0" BELOW GRADE AROUND ENTIRE " FROM THE DIMENSIONS SHOWN. SHINGLES (PROV. 1 COAT BLEACHING OIL), 1/2"GYP. BD..(SCREWEO/TAPED) BASEMENT PERIMITER. INTERIOR DOOR- 2'4"X 6'8" SOLID PINE DOOR WITH RAISED PANELING, PROV O.N.O.. DOWNLIGHT TRIMS TO BE WHITE CUR. PINE 4" COLONIAL BASE TRIM, & R-19 FOIL FACE INSUL. (HIGH DENSITY). 2 - 4. THE CONTRACTOR SHALL SUPPLY ALL LABOR AND MATERIAL SHOWN ON THE BASEMENT CEILING: R-19 KRAFT-FA, INSULATION WITH PROPER WIRE TIES O DRAWINGS UNLESS OTHERWISE NOTED, NEW INTERIOR PARTITION- 2" X 4"WOOD STUD WALL WITH 1/2" GYP. BDINTERIOR DOORS- PAIR 2'O"X 6'8" SOLID PINE DOORS WITH RAISED PANELING. . INSTALLED AS PER N.Y.S. BUILDING CODE. SOL DS BRASS HINGES &SCHLAGE HARDWARE. 4) DUPLEX ELECTRICAL RECEPTACLE E z (SCREWED/TAPED) APPLIED BOTH SIDES. NOTE. PROVIDE MOISTURE O PROV.INTER3 m 5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ADEQUATELY BRACING AND RESIST GYP. BD. (GREEN BD ) FOR ALL BATHROOM WALL AND CEILINGS. tGFI DUPLEX RECEPLTACLE/GROUND FAULT INTERRUPT O i€ PROTECTING ALL WORK DURING CONSTRUCTION AGAINST DAMAGE, BREAKAGE, PROV CEMENT WALL BD. FOR ALL TILE AREAS. COLLAPSE, DISTORTION, AND MISALIGNMENT ACCORDING TO ALL APPLICABLE Esc DUPLEX SEPARATE CIRCUIT RECEPTACLE • CODES. INTERIOR PAINT-TO BE "BENJAMIN MOORE" U.O.N. ONE COAT PRIMER AND 22'_9„ E TWO COATS FINISH (COLORS T.B.D. BY OWNER) SATIN FIIN. THROUGHOUT $ WALL SWITCH $a 4-WAY WALL SWITCH 6. THE CONTRACTOR SHALL PAY FOR AL PERMITS, FEES AND COSTS RELATED TO U O N. ALL TRIM SEMI-GLOSS. 7-0 14'-3" - THEWORKOFTHISCONTRACT. CONTRACTORS SHALL INITIATE ALL REQUIRED - - - - - - - - - - - - - - -- - - - - - - - - - - -� $a 3-WAY WALL SWITCH $ € g INSPECTIONS OF ALL WORK COMPLETED UNDER THIS CONTRACT. s 5-WAY WALL SWITCH U Z) 0 w, 7. THE CONTRACTOR SHALL AT ALL TIMES KEEP THE PREMISES CLEAN AND IS pJB WALL MOUNTED JUNCTION BOX 1€ c o6 L RESPONSIBLE FOR REMOVAL OF ALL RUBBISH FOR ALL TRADES FROM THE JOB SITE. PLUMBING LEGEND : 1$)" RECESSED DOWNLIGHT (100w) LIGHTOILER OR APPROVED EQUAL JR CEILING MOUNTED JUNCTION BOX T. B, ANY"EXTRAS" FOR ALL OR LEGITIMATE UNFORESEEN CONDITIONS SHALL BE DOCUMENTED WITH THE COST OF APPROVAL BY OWNER OR HIS AGENT PRIOR TO PROVIDE ALL NECESSARY PLUMBING ROUGHING AND VENTING AS INDICATED - STARTING ADDITIONAL WORK P ON CONSTRUCTION PLANS) FOLLOW ALL NECESSARY' N.Y C. AND N Y.S ;• - 9. DOUBLE JOISTS ARE TO BE INSTALLED UNDER ALL WALL PARTITIONS RUNNING BUILDING CODES THAT APPLY TO WORK BEING COMPLETED, PROV. ALL �E EXTERIOR MOUNTED DOWNLIGHT (100W) NECESSARY DRAIN VALVES. �i1%1 PARALLEL TO THE FRAMING. PROVIDE DOUBLEHEADER JOISTS AT ALL OPENINGS. SITs � '�•``� SIi1, WALL MOUNTED DUAL SPOT LIGHTiQ�� REFER TO CONSTRUCT DRAWINGS FOR SIZES. *F PROV. FLOOR DRAIN AND 10. GAL, SUMP. NEW CEILING MOUNTED JUNCTION BOX FOR RECESSED EXHAUST 9 10. ALL FRAMING LUMBER TO BE DOUGLAS FIR #2 CONS_ GRADE OR BETTER. eF FAN/LIGHT WITH DUAL SWITCH AT WALL. "BEGAN" HEAVY DUTY UNIT 9eEIN @ 17. THE CONTRACTOR SHALL PROVIDE SHOP DRAWINGS FOR ALL SPECIAL WORK *HB PROVIDE FROST FREE HOSE BIBS. OR APP. EQUAL. k v � N, SUCH AS BUT NOT LIMITED TO: MILLWORK, SPRINKLER SYSTEMS AND STEEL WORK. p'`w J2' I�QUA ALL SHOP DRAWINGS NEED THE APPROVAL OF THE ARCHITECT BEFORE *S SHOWER HEAD EXT. MOUNTED LIGHT WITH FAN .. F � 31RIN R � PROCEEDING. so RU SMOKE DETECTOR/CARBON MONOXIDE DETECTOR: TO BE v, F HARD WIRED TO CENTRAL CONTROL BOX ;€ I FLOORING LEGEND : WINDOW LEGEND : LINE OF DECK ABOVE. aT CABLETNEW RECEPTACLPHONE E II '' _ - -- -- --- '- 25-3" QG CABLE TV RECEPTACLE LL ® HARDWOOD FLOORING-SELECT WHITE OAK 2 1/4"W 15LB. FELT., NOTE ALL INTERIOR CASING TO BE STANDARD COLONIAL CA\SING CLEAR PINE .� (3 FINISH COATS OF OIL BASED SATIN POLYURETHANE. UNLESS OTHERWISE NOTED. >Y VACUUM OUTLET (PROVIDE NECESSARY ELEC. POWER) Z �� NOTE: ALL WINDOWS TO BE MARVIN WITH STANDARD MARVINJ HARDWARE. 6'-6" 6' 7'-0" 9'-8" 9'-8" 13'-1" Z' SUB-FLOOR-USE 3/4"THICK PLYWOOD GLUED AND NAILED. ALLOW FOR EXTENSION JAMBS FOR AN 8" CONC. BLOCK WALL. LL SUB FOR TILE AREAS TO BE SCREWED AND GLUED, COLOR TO BE WHITE. PROV. SCREENS FOR ALL WINDOWS ® EXISTING WOOD FLOOR TO BE SANDED & REFINISHED W/2 COATS SATIN REF. POLY ( P. ALL AREAS) PATCH ALL AREAS AS REQUIRED) A CAWN 2432 B CAWN 2428 C CCM 28136 (EGRESS) '• V T' CERAMIC TILE - "AMERICAN OLEAN" TILE OR APP. EQ. TILE TO BE INSTALLED OD CCM 2840 (EGRESS) OE CCM 2856 (EGRESS) FO CUDH 22424 (EGRESS) 31\ ®T. OVER 1/2" CEMENT BOARD U.O.N. WALL AND FLOOR GROUT TO HAVE O O CUDH 2620 0 G CUDH 2620 H J CUDH 2626 WATERPROOF ADDITIVE MIXED IN. K CUDH 3024 L CUDH 3030 M CUDHP 4042 .;• „" 7 8 III 2 ®;zCCA CIF6 OVE III 7 7 oCUDHP 6062 OO CUDHP 6854 ©CUDHP 6858 HEATING/AC : -- ©CUDH 2014 ®EXISTING WINDOW 1'-10" \ \1 6-7" Q, MM 7' FLOOR REGISTER (7" SUPLY DUCT) V.I.F. T:JI� 1 r J71 r ��l DUCTWORK IN FLOOR BELOW - - - - - - - - - -- - — =r�";� •il I �) L ' ,• I ". \ \\ Ll l (ROUTING SUBJECT OT CHANGE) f I—.•` I _I �^l LL kkH RETURN REGISTER R REGISTER (CEILING) V e Ja // UP III 2" X 10" CCA PJ. ABOVE_ 7'-e" 2"X 10" CCA FJ. ABOVE I �� LINE OF DECK ABOVE. ® III III III c'' 012" O C. (TYP) / @7 2" O.C. (TYP) RETURN REGISTER (WALL) T-1 V. —' — e a V. .F. III V'-FI III III III '_3" 71 KITCHEN EXHAUST REGISTER (CEILING) V I F. V. F 1\J\ — — — \ /, I III III ILII �, so 1i t - - - - - - - -- -I- - r - - - - - -- III L 1,_6,�V.LF / / - - - - - IO I I aooAnnP. : ' / ' L — / 1 III 5' T 6'_11° \In ELEC. PNL. / IV.I F 5,_6�i .LFI � R , _ - - -Ja + - � - � � _ _ _ _ - - __ _ � fJi :� 3 6" I N LL I I / / III – L'.` :1 Cr Ck) 1'_6" .LF. JIB L 7'-11" o UJ LJJvLF.I t — — — — — 3�3 - - ' � - - -. � �� � _ Ja JB B — — — R 1 J6 — _ III B PER9TORE P — LL 1 TxVBLOCKx B" D. PEIR III O . III \ \ — SII- / / I r — - - � III V. F. Gl Gl Gl 0 2'a 2'x 10" D. P. CONC FTG. to f TYP. ALL X'- B-8 � � fellI _ —®1101 III 24'_2,1 III N � 8'-3" ' I I I ' I r , f — — l I.,9.P--'I ¢ ¢ ¢ W _ II II -I I 0 IL iL 0 0 Z 18, - - -- -i. . z, Uo' ccAFJ. ABOVE r �w w w o I o cl •I+':}'. ? 1 it — _X l:, 1.1 V.I.F. I ' ®"•1 2" O.O, (TYP) U U U m — - - R I V. .�.�2 @72�O CFJTAPBOVE � �� � �e Lam— � 2'-9' - O O D W I I1 II III _ > > co > / - - - 1- - i IIII 5'-5" to to �II�a" �,I®a III III V.I.F. p_B„ — — = - - - - - %7= - - r II III r 1 2003 0 e o I I � 13 , III �I}� � W L- - - - - - - - — - - -- - - - - - - - - - - - - — 11 — — D! J, r - -1 X11 - 7 — r; .-1- -- - 24-4, — --?• .- - - -- - - - 1. _ _ _ _ � FILE NAmr FER OC _ R L., •7U h'®',• —! . -1 r;..:jI_a I,+; O E— .1 `�,_.i, V.I.F. J IIIA SCALE 4 01 CA \\ \\\ / /— �z @12CO.C.CA FPOVi 10,_4�1 /2 @02CO CF(JTAP OVA III /2"�O2COCACF(JTAB OVA IIII S 1/4u=_1'0n 2" X 1 O" C'C ABOVE @12° IO.C. , III o DWG. NA',AE: iil, CSL FOUNDATION ter PL�PJ __ _ I I ?1` _ — _ _ — — ... — � -- 1 . , (I 10' 4," T3" THESE DRAWINGS AS INSTRUMENTS OF SERVICE, EA . � I!" LINE OF DECK ABOVE. AREEVISOLS PROPERTY ARCHITECT (,) 2'-9" 13 6 FOUNDATION PLAN\N SH LL BE ALL CHANGES,AND/OR MODIFICATIONS _ SHALL A ALLOWED WITHOUT WRITTEN AUTHORIZATION BY THE ARCHITECT ANY REPRITEDB I-AW PART _ OR WHOLE IS STRICTLY PROHIBITED RV LAW i� GENERAL NOTES : CONSTRUCTION LEGEND_ INSULATION NOTES : PLUMBING LEGEND_ ELECTRICAL LEGEND : , I- 1. ALL WORK SHALL COMPLY WITH FEDERAL, STATE, AND LOCAL BUILDING CODES EXISTING EXTERIOR PARTITION TO REMAIN. PROV. 1/2" GYP. BD &R-15 HIGH EXISTING EXTERIOR WALLS: 2"X4"WOOD STUD. R-,5 HIGH DENSITY INSULATION PROVIDE ALL NECESSARY PLUMBING ROUGHING AND VENTING AS INDICATED NOTE ALL ELECTRICAL WORK TO BE IN ACCORDANCE WITH THE RULES AND AND ORDINANCES DENSITY INSULATION TO ALL EXISTING EXTERIOR WALLS. BY'CERTANTIEED' OR APPROVAL EQUAL. P ON CONSTRUCTION PLANS). FOLLOW ALL NECESSARY N.Y.C. AND N.Y S. REGULATIONS OF THE N.Y.B F U AND A CERTIFICATE FROM THE N Y B.F.U. IS TO BUILDING CODES THAT APPLY TO WORK BEING COMPLETED. PROV. ALL BE PRESENTED TO THE OWNER AT THE COMPLETION OF THE JOB. h 2. BEFORE COMMENCEMENT OF WORK, THE CONTRACTORS SHALL FURNISH THE EXISTING INTERIOR PARTITION TO REMAIN. PROV. 1 LAYER 1/2" GYP, BD. BY'CERTAINTEED'OR APPROVED EQUAL. NECESSARY DRAIN VALVES. OWNER AND ARCHITECT WITH COPIES OF ALL REQUIRED INSURANCE AND BOTH SIDES OF EXISTING WOOD STUDS CLR. PINE 4" COLONIAL BASE TRIM. NOTETHE OWNER SHALL PROVIDE ALL LIGHTING FIXTURES UNLESS OTHERWISE j O WORKER'S COMPENSATION CERTIFICATES AND NAMES OF ALL SUBCONTRACTORS, NEW ROOF R-30 KRAFT-FA INSULATION BY'CERTAINTEED' OR APPROVED EQ. •R ELECTRICAL CONTRACTOR PROV FLOOR DRAIN AND 10. GAL. SUMP. NOTED. ALL OTHER ELECTRICAL EQUIPMENT AND MAT-L. TO BE SUPPLIED BY THE UUUF - . od NEW EXTERIOR PARTITION- 2"X 4"WOOD STUD WALL W/ 1/2" COX PLYWD. 7 3 THE CONTRACTORS SHALL BE RESPONSIBLE FOR ALL DIMENSIONS AND ;I„l EXTERIOR SHEATHING (TWEK WRAPPED &TAPED), 6” EXPOSURE PERF. WD. CRAWL SPACE: R-19 KRAFT-FA. INSULATION WITH PROPER WIRE TIES HB PROVIDE FROST FREE HOSE BI85. NOTE: ALL SWITCHES AND RECEPTACLES TO BE 'LUTRON', "DECORA" IN COLOR 7 _ CONDITIONS ON THE JOB. THE ARCHITECT MUST BE NOTIFIED OF ANY VARIATIONS SHINGLES (PROV. 1 COAT BLEACHING OIL), 1/2" GYP. BD (SCREWED/TAPED) INSTALLED AS PER N.Y S. BUILDING CODE. O.N.O.. DOWNLIGHT TRIMS TO BE WHITE. FROM THE DIMENSIONS SHOWN. CLR PINE 4" COLONIAL BASE TRIM, & R-19 FOIL FACE INSUL. (HIGH DENSITY). NEW BASEMENT: R-,O RIGID FOAM 20" BELOW GRADE AROUND ENTIRE *S SHOWER HEADl L) ` 4. THE CONTRACTOR SHALL SUPPLY ALL LABOR AND MATERIAL SHOWN ON THE NEW INTERIOR PARTITION-2" X 4"WOOD STUD WALL WITH 7/2" GYP. BD. BASEMENT PERIMITER. NOTE: ALL OUTDOOR LIGHTS AND PORCH LIGHTS ARE CONTROLLED BY TIMERS �( ' LOCATED IN ELECTRIC PANEL DRAWINGS UNLESS OTHERWISE NOTED. (SCREWED/TAPEO) APPLIED BOTH SIDES. NOTEPROVIDE MOISTURE BASEMENT CEILING R-19 KRAFT-FA. INSULATION WITH PROPER WIRE TIES '?1 L, S. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ADEQUATELY BRACING AND RESIST GYP. BD. (GREEN BD ) FOR ALL BATHROOM WALL AND CEILINGS. INSTALLED AS PER N.Y.S. BUILDING CODE G z ti PROTECTING ALL WORK DURING CONSTRUCTION AGAINST DAMAGE, BREAKAGE, PROV. CEMENT WALL BD. FOR ALL TILE AREAS. zz DUPLEX ELECTRICAL RECEPTACLE O j COLLAPSE, DISTORTION, AND MISALIGNMENT ACCORDING TO ALL APPLICABLE INTERIOR PAINT-TO BE "BENJAMIN MOORE" U.O N ONE COAT PRIMER AND - GFI DUPLEX RECEPLTACLF✓GROUND FAULT INTERRUPT � CODES. TWO COATS FINISH (COLORS T.B.D. BY OWNER) SATIN FIN. THROUGHOUT U.O.N. ALL TRIM SEMI-GLOSS. SC DUPLEX SEPARATE CIRCUIT RECEPTACLE 6. THE CONTRACTOR SHALL PAY FOR AL PERMITS, FEES, AND COSTS RELATED TO _ Tj THE WORK OF THIS CONTRACT CONTRACTORS SHALL INITIATE ALL REQUIRED WALL SWITCH 3 WAY WALL SWITCH a -WAY WALL SWITCH _ INSPECTIONS OF ALL WORK COMPLETED UNDER THIS CONTRACT DOOR LEGEND : CEILING MOUNTED JUNCTION BOX WALL MO $ $ 3 C 4 7. THE CONTRACTOR SHALL AT ALL TIMES KEEP THE PREMISES CLEAN AND IS � _ .. (1�� - RESPONSIBLE FOR REMOVAL OF ALL RUBBISH FOR ALL TRADES FROM THE JOB SITE, NOTE. ALL INTERIOR CASING TO BE STANDARD COLONIAL CASING CLEAR PINE OILE L UNTIED JUNCTION BOX q �. UNLESS OTHERWISE NOTED, PROV. SCREEN DOOR UNITS FOR ALL EXT DOORS. \ RECESSED DOWNLIGHT (,OOw) „LIGHTOILER" OR APPROVED EQUAL 1r�I .� 06 S. ANY"EXTRAS" FOR ALL OR LEGITIMATE UNFORESEEN CONDITIONS SHALL BE E EXTERIOR MOUNTED DOWNLIGHT (1 OOW) ` o ai L DOCUMENTED WITH THE COST OF APPROVAL BY OWNER OR HIS AGENT PRIOR TO Ex EXISTING DOOR TO BE REPAIRED & RE-USED. \ - STARTING ADDITIONAL WORK. III �(T M EXTERIOR DOOR- 3'6"X 6'8" SOLID PINE DOOR WITH RAISED PANELING. PROV. 1A[JB WALL MOUNTED DUAL SPOTLIGHT y� LL 9. DOUBLE JOISTS ARE TO BE INSTALLED UNDER ALL WALL PARTITIONS RUNNING O SOLID BRASS HINGES & SCHLAGE HARDWARE. \ �FE EXHAUST FAN UNIT (FLUSH) t' ry�' I� - PARALLEL TO THE FRAMING. PROVIDE DOUBLE HEADER JOISTS AT ALL OPENINGS, MOO NEW CEILING MOUNTED JUNCTION BOX FOR RECESSED EXHAUST (1 N ` ` I REFER TO CONSTRUCT DRAWINGS FOR SIZES. 2 EXTERIOR DOOR- 5'3"X 6'8" SINGLE FRENCH DOOR AND SIDIELIGHTS WITH RAISED IEF FAN "BROAN" HEAVY DUN UNIT OR APP EQUAL °+ SII: O PANELING. PROV. SOLID BRASS HINGES & SCHLAGE HARD\WARE. \ i+\ ', `� I 10. ALL FRAMING LUMBER TO BE DOUGLAS FIR #2 CONS.. GRADE OR BETTER - - - _ - - _ - ��,,\` L 3 EXTERIOR DOORS- 3'2"X 6'8" SOLID PINE DOOR WITH RAISED PANELING. -Q' '=1� �� O PROV. SOLID BRASS HINGES & SCHLAGE HARDWARE. - III P EXT. MOUNTED LIGHT WITH FAN �\ \ ;y 11. THE CONTRACTOR SHALL PROVIDE SHOP DRAWINGS FOR ALL SPECIAL WORK X .j� SUCH AS BUT NOT LIMITED TO: MILLWORK, SPRINKLER SYSTEMS AND STEEL WORK. D PS PS ALL SHOP DRAWINGS NEED THE APPROVAL OF THE ARCHITECT BEFORE 4 EXTERIOR DOOR- 2'8"X 6'8" STATIONARY FRENCH DOOR WIITH RAISED PANELING. SSD SMOKE DETECTOR/CARBON MONOXIDE DETECTOR: TO BEik ''.c4 � \'S PROCEEDING. O PROV SOLID BRASS HINGES &SCHLAGE HARDWARE \ \ HARD WIRED TO CENTRAL CONTROL BOX ISO, � III EXTERIOR DOORS- 5'4" X 6'8" PAIR FRENCH DOOR WITH RAISED PANELING. \ 4 r NEW TELEPHONE RECEPTACLE E�� �EIII � O PROV. SOLID BRASS HINGES &SCHLAGE HARDWARE. L \\ ',���� � _ I d CABLE 7V RECEPTACLE I""""`" FLOORING LEGEND : © EXTERIOR DOORS- &T X 6'8" SOLID PINE DOOR WITH RAISEED PANELING. —\\ \ / �I III C W PROV. SOLID BRASS HINGES & SCHLAGE HARDWARE. \ DY VACUUM OUTLET (PROVIDE NECESSARY ELEC. POWER) EXTERIOR DOORS- 4'0" X 6'8" PAIR FRENCH DOOR WITH RAISED PANELING. 77IIT� U HARDWOOD FLOORING-SELECT WHITE OAK 21/4"W., 15LB FELT., O PROV. SOLID BRASS HINGES & SCHLAGE HARDWARE. � III SV[ps PHOTO SENSOR SCONCES WALL MOUNTED DUAL SPOT LIGHT v ® (3 FINISH COATS OF OIL BASED SATIN POLYURETHANE. / _ EXTERIOR DOORS- 2'e"X 6'8" SOLID PINE DOORS WITH RAISEDBAR ELEVATIO PANELING. NS TO CONTROL ALL CONECTING JB. PROVIDED BY HOME OWNER z SUB-FLOOR-USE 3/4" THICK PLYWOOD GLUED AND NAILED. OB PROV. SOLID BRASS HINGES & SCHLAGE HARDWARE. 1 A 2 \ W III HB NOTE. PROVIDE TEN LIGHT FIXTURES THROUGHOUT DRIVEWAY WITH SUB FOR TILE AREAS TO BE SCREWED AND G O PROVRIOSOLIDOBRASS HINGES &OLID PINE SCHLAGE HAORS WITH RDWARE. EXISTING RAISED PANELING. Y I I I --_ \ ONE OPERATING SWITCH '^ � ® EXISTING WOOD FLOOR TO BE SANDED & REFINISHED W/2 COATS SATIN INTERIOR DOORS- 20"X 6'8" SOLID PINE DOORS WITH RAISEED PANELING. / ( h REF POLY (TYP. ALL AREAS) PATCH ALL AREAS AS REQUIRED) 1O PROV. SOLID BRASS HINGES & SCHLAGE HARDWARE. NOTE' PROVIDE FIVE LIGHT FIXTURES 11VJ , INTERIOR DOORS- 2'4" 6' X 8" SOLID PINE DOOR WITH RAISEED PANELING. PROV.8 ZONE TIMER FOR ONE OPERATING SWITCH /T \ THROUGHOUT LANDSCAPE WITH W CERAMIC TILE - "AMERICAN OLEAN"TILE OR APP. EQ TILE TO BE INSTALLED 11 PROV. SOLID BRASS HINGES &SCHLAGE HARDWARE. EXTERIOR LIGHTING. PROV. ! III \ ® OVER 1/2" CEMENT BOARD U.O.N WALL AND FLOOR GROUT TO HAVE ZONE 1NELOVERTLI ZONEI -PORPORTLIGHTS (� WATERPROOF ADDITIVE MIXED IN. 12 INTERIOR DOORS- 2'6" X 68"SOLID PINE DOOR WITH RAISEED PANELING. ZONE 3-PORCH LIGHTS ®' O PROV SOLID BRASS HINGES &SCHLAGE HARDWARE. ZONE a-PORCH LIGHTS - 1 R ZONE4 PORCH LIGHTS �y INTERIOR DOORS- 218" X 618" SOLID PINE DOORS WITH RAISED PANELING. ZONE -PORCH LIGHTS ZONES-LANDSCAPE LIGHTS 13ZONE]-LANOSOAPE LIGHTS NEW300AMP. WINDOW LEGEND : PROV. SOLID BRASS HINGES &SCHLAGE HARDWARE. ZONE e-LANDSCAPE LIGHTS ELEc.PANEL - INTERIOR DOOR- 3'O"X 6'8" SOLID PINE DOORS WITH RAISEID PANELING. 14 N � T III HARDWARE. SII IB. J j NOTE: ALL INTERIOR CASING TO BE STANDARD COLONIAL CASING CLEAR PINE O PROV. SOLID BRASS HINGES & SCH SCHLAGE HAR / I- I^ I UNLESS OTHERWISE NOTED. INTERIOR DOORS- 2'4"X 6'8" SOLID PINE POCKET DOOR WITTH RAISED PANELING. III - pI 1 } I ,5 PROV. SOLID BRASS HINGES & SCHLAGE HARDWARE. /Te1 ( P I I I NOTE: ALL WINDOWS TO BE MARVIN WITH STANDARD MARVIN HARDWARE. - - uP - - \ T III T j I 'W CALLOW FOR OLOR TO BE WH TE PROV. SCREFOR ENS FOR RONC LL WIN DOWS LOCK ALL 16 ROV.INTERIOR SOLIID BRASS H NGES &PAIR SCHLAGE PINE HARDWA HARDWARE WITH RAISED PANELING E / m \ N, 12 LL BATH BATH ' GB IL R / T 1111 0 32 A/C 5'0" X 8'0" 5'0" X 6'6" /' 9�Exlls ING) ©CAWN 2428 OD CCM 2840 (EGRESS) EO CCM 2856 (EGRESS) 3 FO CUDH 2424 EGRESS OG CUDH 2620 H CUDH 2620 5' 1 6 \ / RO 32 2/8'!X 60 7/8" ® \ \ ` I ® I / I\\ B O JOFIER CUDH 2626 OCUDH 3024 ® CUDH 3024 w/DIV. i r L !3 / ' (l� - ©CUDH 3030 OM CUDHP 4042 ON CUDHP 6062 \� J GPI J H J REF, JB L B T V I_ \ I- ©CUDHP 6858 ©CUDH 2014 ®EXISTING WINDOW 'I ®\ O 0P / / \\ c r - R - II c T s 6" �� LL V I P \\ 3 w EATING AC : — - - - - - - a E — --- R0423/8" X447/8" - JB \ - FJ O � / `\ � II ®7" FLOOR REGISTER (7" SURLY DUCT) -�_ - - AI --_ ® J� / - REF. DUCTWORK IN FLOOR BELOW M — - -I- ` - -/ - - _ --- — 3� (ROUTING SUBJECT OT CHANGE) I3� _ -- ` - - �i N Rl 110 `\ - 3 (CEILING) \ T I - - SUPPLY REGISTER (CE ) \pry/ IIS - ® -i I- — O - ri �R ASO \ / REF - I 171 RETURN REGISTER (CEILING) -J - -/ 1 ® \I I O - — JB \ r REF JB lD H 0 0 - PANTRY - -- - - _ - - - RETURN REGISTER (WALL) ��T JB 9'6"-X 12,6° I� _ / � II � � ® H6 a O C 1 — — — / ¢ KITCHEN EXHAUST REGISTER (CEILING) (EXISTING) H / _ /3 a a - _ _ - -� 0 I,L v / LJ Tr> \\ / / - I jo RBF — --- — — \ -- Sc P 1 / \ vI it — tt 6 3 '- � I - 2 D I, �V JBLd — O H h- 11 J a � W O --I I ® O LIBRARY ° 9 1510" x 19110" m m 0 (EXISTING) SUNROJB d V _ A w w w B B / —� ow 3 - - - v / A I. � meEze" r o.w, _. � � II � I I II D � O O — J _ O O CO — B v" A D ( —I SC P 3 P SC SC P JB " SC P GFI --- Ta JB O N 0 lull lull [L — �— ._. — ryJ O O W `I� FD 7 4 UI D e FILE NAME: 3' R _ _ 8 . 1CP�� �\ �XX FER CUR P \� ' A 03/01/02 SCALE. I T ^ I T B T JB I D WG. NAME LILL _ � Io \ FIRST =L_. PLAN I LL [:A NO 'THESE DRAWINGS AS INSTRUMENTS OF SERVICE,ININ RM. LIVING RM . ARE EVI SOLSP CHANGESOPERTY OFTHEARODIFIC T. D G SH LL EIONS,CHANGES,AND/OR MODIFICATIONSSHALL A ALLOWED WITHOUT WRITTENAUTHORIZATIONKITCHEN FIRST FLOOR PLAN . II 12'0" X 15'0" — — 160" X 24'6" 1 T10" X 24'6° BY THE ARCHITECT. ANY REPRODUCTION IN PART (EXISTING) (EXISTING) (EXISTING) OR WHOLE IS STRICTLY PROHIBITED BY LAW. TOTAL SQ.FT. = 2,903 NOTE: GUSSET PLATES TO BE 1/4" THICK STEEL S+ W/1/2" STEEL CARRIAGE BOLTS. USE 6 BOLTS PER 5 { GUSSET FLANGE. GUSSET BEND FLANGE # OF O DETAIL ANGLE LENGTH PLATES T �" � il fJ v "A" 135' 2" q BEAM 2- 1 3/4"X 11 7/8" MICROLAM Bo 45� 4" 6 2" X 12" BEAM -� O BEAM U y Q E � z = cl I d� — � h 2- 1 3/4" X 1'I 7/8" \J MICROLAM \TT b w �/ ' "Allk m BEAM 0 10 5/8" X NEW 2" X 10" C.J. W E N / 1 11 7/8" 11 7/8" III_ @ 16�� _ NE 6F0CD„ CJ _ BA 51/2" X Igq IS %I" `f 1 71 7/8” 2- 1/ / III_= III III BEAM 4"X 11 7/8" MICROLAM L LIVING RM . CEILING_ _ -- � 2"X e" R.R. I�1 @ 16" O.C. KITCHEN CEILING _ _ - _ � @ 6�O C. R.R. 2-1 3/4"X 9 1/211 III 813/4"X 11 7/8" MICROLAM __ _ -_ -� �III � HB II II IIII I � ILII W III IL �I � d II � b � z > 0 2- 1 3/4"X 17 7/8" MICROLAM BEAM < O Il d d I! II IIx JI! 11 II Holl II I II II I _ <V , N, W II �IIz �J 1111 I 11BI I N /� E III II J = IIJV11 Q I _ o II II II II II III III II !!Q II II II II LII II I'L II III— - — - � !iX�ll XIII III— — CONSTRUCTION LEGEND : DOOR LEGEND : PROVIDE 2093 PROVIDE 211 HE THIRD FLOOR ELECTRICAL LEGEND': THIRD FLOOR _ HERBEAU SHOWERHEAD RBEAU SHOWERH EAD '— WITH ROYAL SLIDEBAR & HAND NOTE: ALL ELECTRICAL WORK TO BE IN ACCORDANCE WITH THE RULES AND 2-8 SPRAY "3041" & "3046" PROVIDE 2093 REGULATIONS OF THE N.Y.B.F.U. AND A CERTIFICATE FROM THE N.Y.B.F.0 IS TO EXISTING EXTERIOR PARTITION TO REMAIN. PROV. 1/2" GYP BD. & R-15 HIGH NOTE: ALL INTERIOR CASING TO BE STANDARD COLONIAL CASING CLEAR PINE HERBEAU SHOWERHEAD -, DENSITY INSULATION TO ALL EXISTING EXTERIOR WALLS. UNLESS OTHERWISE NOTED, PROV. SCREEN DOOR UNITS FOR ALL EXT. DOORS. BE PRESENTED TO THE OWNER ID THE COMPLETION OF THE JOB z _ 1'-4" PROVIDE 211 HERBEAU SHOWERHEAD _P EXISTING INTERIOR PARTITION TO REMAIN. PROV 1 LAYER 1/2" GYP. BD. x EXISTING DOOR TO BE REPAIRED & RE-USED. WITH ROYAL & "304 AR & HAND NOTED. ALL OTHER ELECTRICAL EQUIPMENT AND MATURES UNLESS OTHERWISE -y SPRAY"3041" & "3046" THERMOSTATIC VALVE ELECTRICAL CONTRACTOR G FIXTURES DECORA" IN COLOR -- NOTE. THE OWNER SHALL PROVIDE ALL LIGHTIN - BOTH SIDES OF EXISTING WOOD STUDS. CUR. PINE 4" COLONIAL BASE TRIM PROVIDE 30497° 3/4" O - EXTERIOR DOOR- 3'6"X 6'B" SOLID PINE DOOR WITH RAISED PANELING. PROV WALL VALVE O - 1 } -IA„\ O THERMOSTATIC VALVE LTO BE SUPPLIED BY THE , �F NEW EXTERIOR PARTITION- 2"X 4"WOOD STUD WALL W/ 1/2" CDX PLYWD 1 '%1 n PROVIDE 304470 ' , EXTERIOR SHEATHING (Tl'VEK WRAPPED &TAPED), 6" EXPOSURE PERF. WD SOLID BRASS HINGES &SCHLAGE HARDWARE. PROVIDE 304470 1�t1„ 1'-11" 3/4" WALL VALVE NOTE: ALL SWITCHES AND RECEPTACLES TO BE 3/4"WALL VALVE ONO . DOWNLIGHT TRIMS TO BE WHITE. ` U SHINGLES (P ROV. 1 COAT BLEACHING OIL), 1/2" GYP. BD.(SCREWED /TAPED) O EXTERIOR DOOR- 5'3"X 6'8" SINGLE FRENCH DOOR AND SIDELIGHTS WITH RAISED - ,c o ?v CUR PINE 4" COLONIAL BASE TRIM, & R-19 FOIL FACE INSUL (HIGH DENSITY) 2 PANELING. PROV. SOLID BRASS HINGES & SCHLAGE HARD\WARE tD DUPLEX ELECTRICAL RECEPTACLE O O EXTERIOR DOORS- 3'2"X 6'8" SOLID PINE DOOR WITH RAISED PANELING. 3-2 2'-6° PROVIDE 8"WALL FOR PROVIDE 8" WALL FOR 2, 6„ 3' 2" V'GR DUPLEX RECEPLTACLE/GROUND FAULT INTERRUPT RESIST VP BD. GREEN BI WOOD STUD WALL WITH 1/2" GYP. RD. KITCHEN VENTING KITCHEN VENTING E ' N U NEW INTERIOR PARTITION- 2"X 4' 3 ( ) H SIDES. NOTE' PROVIDE MOISTURE PROV. SOLID BRASS HINGES & SCHLAGE HARDWARE, R ALL BATHROOM WALL AND CEILINGS SECOND FLOOR Qbsc DUPLEX SEPARATE CIRCUIT RECEPTACLE PROV. CEMENT WALL BD. FOR ALL TILE AREAS. 4 EXTERIOR DOOR- 2'8"X 6'8" STATIONARY FRENCH DOOR WITH RAISED PANELING. SECOND FLOOR O PROV. SOLID BRASS HINGES & SCH AGE HARDWARE. $ WALL SWITCH INTERIOR PAINT-TO BE "BENJAMIN MOORE" U.O.N. ONE COAT PRIMER AND EXTERIOR DOORS- 5'4"X 6'8" PAIR FRENCH DOOR WITH RAISED PANELING. r a.L TWO COATS FINISH (COLORS T.B.D. BY OWNER) SATIN FIN THROUGHOUT O PROV. SOLID BRASS HINGES & SCH SCHLAGE HARDWARE MASTER BATH-SHOWER MASTER BATH-SHOWER -' 2A 2 $3 3-WAY WALL SWITCH $q 4-WAY WALL SWITCH $s 5-WAY WALL SWITCH p" �' I iJ A.2 T` \) i U O.N. ALL TRIM SEMI-GLOSS. 6 EXTERIOR DOORS- 3'3" X 6'8" SOLID PINE DOOR WITH RAISED PANELING. O PROV. SOLID BRASS HINGES & SCHLAGE HARDWARE. e CEILING MOUNTED JUNCTION BOX ce w h INSULATION NOTES_: EXTERIOR DOORS- 4'0" X 6'8" PAIR FRENCH DOOR WITH RAISED PANELING N O EXTERIOR PROSOLID BRASS HINGES & IR FRENCH SCHLAGE HARDWARE. Je WALL MOUNTED JUNCTION BOX e EXTERIOR DOORS- 2'8"X UE!" SOLID PINE DOORS WITH RAISIED PANELING. RECESSED DOWNLIGHT (100w) "LIGHTOILER" OR APPROVED EQUAL r OPROV. SOLID BRASS HINGES &SCHLAGE HARDWARE. C7 N CLI EXISTING EXTERIOR WALLS: 2"X4"WOOD STUD. R-15 HIGH DENSITY INSULATION �r m EXTERIOR DOORS- 3'6" X 68" SOLID PINE DOORS WITH RAISIED PANELING. E EXTERIOR MOUNTED DOWNLIGHT (100W) �+ BY'CERTANTIEED' OR APPROVAL EQUAL. 9 71� - O PROV SOLID BRASS HINGES & SCHLAGE HARDWARE. SALJE WALL MOUNTED DUAL SPOT LIGHT �FE EXHAUST FAN UNIT (FLUSH) Raman� ��L'� INTERIOR DOORS- S HX GE SOLID PINE DOORS WITH RAISIED PANELING, NEW CEILING MOUNTED JUNCTION BOX FOR RECESSED EXHAUST \ ,1 BY 'CERTAINTEED' OR APPROVED EQUAL. 10 PROV. SOLID BRASS HINGES &SCHLAGE HARDWARE. m NEW ROOF. R-30 KRAFT-FA INSULATION BY'CERTAINTEED' OR APPROVED EQ. INTERIOR DOORS- 2'4" X 6'8" SOLID PINE DOOR WITH RAISED PANELING. wEF FAN/LIGHT WITH DUAL SWITCH AT WALL. "BROAN" HEAVY DUN UNIT ; \' % t 1 PROV. SOLID BRASS HINGES &SCHLAGE HARDWARE. OR APP. EQUAL. aU 'xl ,1e' CRAWL SPACE: R-19 KRAFT-FA INSULATION WITH PROPER WIRE TIES ,� �RSy�VI� �+. INSTALLED AS PER N.Y.S BUILDING CODE INTERIOR DOORS- 2'6" X 6'8" SOLID PINE DOOR WITH RAISEID PANELING. F EXT. MOUNTED LIGHT WITH FAN \ ,; 12 PROV SOLID BRASS HINGES & SCHLAGE HARDWARE. �R�'a aRY� \�` �) � NEW BASEMENT: R-10 RIGID FOAM 2'0" BELOW GRADE AROUND ENTIRE �sD SMOKE DETECTOR/CARBON MONOXIDE DETECTOR: TO BE 1 IN 11 INTERIOR DOORS- 2'8" X 6'8" SOLID PINE DOORS WITH RAISIED PANELING. HARD WIRED TO CENTRAL CONTROL BOX ':.0� I' 1 111 BASEMENT PERIMITER 13 PROV SOLID BRASS HINGES & SCHLAGE HARDWARE ���'� � aT NEW TELEPHONE RECEPTACLE ?0 BASEMENT CEILING, R-19 KRAFT-FA INSULATION WITH PROPER WIRE TIES INTERIOR DOOR- 310"X 6'8" SOLID PINE DOORS WITH RAISEID PANELING. CABLE TV RECEPTACLE INSTALLED AS PER N.Y S. BUILDING CODE 14 PROV SOLID BRASS HINGES &SCHLAGE HARDWARE, 4 C INTERIOR DOORS- 2'4"X 68" SOLID PINE POCKET DOOR WITH RAISED PANELING. p VACUUM OUTLET (PROVIDE NECESSARY ELEC. POWER) W Y 15 PROV SOLID BRASS HINGES &SCHLAGE HARDWARE. r , W I N D O 1F 1/\n/ LEGEND : 2'6 6' INTERIOR DOORS- " X 8" PAIR SOLID PINE DOORS WITHI RAISED PANELING. BATHROOM _aPs TOBE ROVIIDPHOTO °ED BY HOME OWNER NES WALL MOUNTED DUAL SPOT LIGHT �J c) 16 PROV, SOLID BRASS HINGES &SCHLAGE HARDWARE 7'6" X 8'O" I W u O NOTE: ALL INTERIOR CASING TO BE STANDARD COLONIAL CASING CLEAR PINE (EXISTING) > UNLESS OTHERWISE NOTED. LL NOTE. ALL WINDOWS TO BE MARVIN WITH STANDARD MARVIN HARDWARE. ALLOW FOR EXTENSION JAMBS FOR AN B" CONC BLOCK WALL. _FLOORING LEGEND : COLOR TO BE WHITE PROV SCREENS FOR ALL WINDOWS ® HARDWOOD FLOORING-SELECT WHITE OAK 2 1/4"W , 15LIB. FELT., ©OUDH \ 2428 OD CCM 2840 (EGRESS) EO CCM 2856 (EGRESS) (3 FINISH COATS OF OIL BASED SATIN POLYURETHANE. FO CUDH 2424 (EGRESS)OG CUDH 2620 OH CUDH 262° SUB-FLOOR-USE 3/4"THICK PLYWOOD GLUED AND NAILED, BEDROOM \\\\ JO CUGH 2626 OK CUDH 3024 ® CUDH 3024 W/DIV. SUB FOR TILE AREAS TO BE SCREWED AND GLUED. 1240" X 180 Q ©CUDH 3030 (p CUDHP 4042 O CUDHP 6062 (EXISTING) \ \ LL ©CUDHP 6658 ©CUDH 2014 ®EXISTING WINDOW ® EXISTING WOOD FLOOR BE SANDED & REFINISHED W//2 COATS SATIN //yy REF. POLY. (TYP. ALL AREAS) PATCH ALL AREAS AS REQUIRED)) LL CERAMIC TILE- "AMERICAN OLEAW TILE OR APP. EQ. TILE TO BE INSTALLED F F F F F \ I Ii ®T OVER V2" CEMENT BOARD U.O.N. WALL AND FLOOR GROUT TO HAVEji LL PLUMBING LEGEND : WATERPROOF ADDITIVE MIXED IN. 56 p RO 30 3/8" X 7/8" 0 PROVIDE ALL NECESSARY PLUMBING ROUGHING AND VENTING AS INDICATED I ° `WK, ISR 11 E - - z P ON CONSTRUCTION PLANS). FOLLOW ALL NECESSARY N.Y.C. AND N.Y.S. \ / BATH ROOM _ Z BUILDING CODES THAT APPLY TO WORK BEING COMPLETED. PROV ALL 0 VALV A2' H. — NECESSARY DRAIN VALVES, SHI�W R 84" H. - 10'6" TI 13'8 _- ol ® �\\- i de -- - - - (EXISTING) _ �F PROV. FLOOR DRAIN AND 10. GAL. SUMP. ® ® � JB - DN. REF. 11 s�� / - - - RD 32 3/8"" X 56 7/8' J I DN. I ISI OHB PROVIDE FROST FREE HOSE BIBS. H a J - cFl Psrr OS SHOWER HEAD Is' d 1 GPI P C T W / i3 �� r ® ® • D 1 FF RD 36 3/8" X 56 7/8" 5 ' 66' � 39. HEATING/AC : Imo_ _ I- _ , - ,tee EGRESS o ®7" FLOOR REGISTER (7" SUPLY DUCT) // / T // ) ® I I z DUCTWORK IN FLOOR BELOW I UP/ ® / - I R I D E OF B =1� III ® W O 3 REF. U) (ROUTING SUBJECT OT CHANGE) REF. / / / s s Ro wAL 0 < / Q Q I ® SUPPLY REGISTER (CEILING) / I // // H RD 32 3/8" X 66 7/8' H VgLVt 42" H. ^^ RETURN REGISTER (CEILING) uP t/J/S SHOWER 84" H. T - - ` \ O LL RETURN REGISTER (WALL) rDo � _ �\ ' 3 P IJR KITCHEN EXHAUST REGISTER (CEILING) _14 _ I N LL W �\p Ex K // 4 \\�� x_zPeruPry 1 33 - - /I t4 �3 FEE. z 12 > i O 4 MASTER BATHROOM FI ' ' E c cc W 3 T 1 3 0 C W / ' � � I �I 1 4 K 'I � LL O 15'0" X 20'0" / I OSD I I 1 e Ja 12 •so (- (EXISTING) \ / P VLF. I iIT" RD 36 3/8"X 56 7/8" 0 U w III / C LL G D 31 J16 ® JB m — ® P P JGFI BEDROOM 15'6" X 1910" 0 (I 0 I�J6 __ (EXISTING) H h F FI \ -- ❑ L 1 ❑ W LI W EDGE OF TUB IS -- - -- -- - - 7 -1 7 12"FROM WALL 1 W REF. 6 REF. ® r' ^J P c 7 8, s. •SD P - _ N _- _ - __ 14 C ii of ER WICIDO }I Ivvu.ly Is RD 363/8' X56 / c - FILE NAME. - - - FER_2CF'_CUR 2-28-32 K K K EGRESS K _ K K SCALE: K yll a � it .• DWG NAP7E: 7" K EGRESS K K � W K '�:I'--,,'i, SECOND FL. u� PLP N I „r^ DWG. NO _ THESE DRAWINGS AS INSTRUMENTS OF SERVICE, ARE THE SOLE PROPERTY OF THE ARCHITECT MASTER BEDROOM SECOND FLOOR PLAN BEDROOM BATHROOM NO REVISIONS, CT. ANY PRT (EXISTING) SBY HALL E ALLOWED WITHOUT WRITTEN AUTHORIZATION 6'0" X 8'6' ECT. ANY REPRODUCTION W PART L.. 16'0" X 18'0)" 13,6„ X 18,0" OR WHOLE IS STRICTLY PROHIBITED BY LAW (EXISTING) TOTAL SQ.FT. = 2,324 (EXISTING) CONSTRUCTION LEGEND : DOOR LEGEND : PROVIDE 2093 ELECTRICAL LEGEND: HERBEAU SHOWERHEAD THIRD FLOOR THIRD FLOOR ' EXISTING EXTERIOR PARTITION TO REMAIN. PROV, t/2" GYP. BD & R-15 HIGH PROVIDE A t HERBEAU &HAND EAD 2'-8" WITH ROYAL SLIDEBAR & HAND DENSITY INSULATION TO ALL EXISTING EXTERIOR WALLS. NOTE: ALL INTERIOR CASING TO BE STANDARD COLONIAL CASIN(u CLEAR PINE SPRAY"3041" & "3046" PROVIDE 2093 NOTE' ALL ELECTRICAL WORK TO BE IN ACCORDANCE WITH THE RULES AND HERBEAU SHOWERHEAD REGULATIONS T THE N.Y.OWN ER AND A CERTIFICATE FROM THE N Y B.F U. IS TO f•L� UNLESS OTHERWISE NOTED. PROV. SCREEN DOOR UNITS FOR ALL EXT. DOORS. BE PRESENTED TO THE OWNER AT THE COMPLETION OF THE JOB. ? q i. -4 PROVIDE 211 HERBEAU SHOWERHEAD z EXISTING INTERIOR PARTITION TO REMAIN PROV. 1 LAYER 112" GYP. Ex EXISTING DOOR TO BE REPAIRED & RE-USED. WITH ROYAL SLIDEBAR & HAND NOTE: THE OWNER SHALL PROVIDE ALL LIGHTING FIXTURES UNLESS OTHERWISE O =1 BOTH SIDES OF EXISTING WOOD STUDS, CUR PINE 4" COLONIAL BASE TRIM. SPRAY"3041" &"3046" PROVIDE 304970 3/4" THERMOSTATIC VALVE NOTED. ALL OTHER ELECTRICAL EQUIPMENT AND MAT-L. TO BE SUPPLIED BY THE OEXTERIOR DOOR- 3'6"X 6'8" SOLID PINE DOOR WITH RAISED PANELING PROV LL VALVE - THERMOSTATIC VALVE ELECTRICAL CONTRACTOR. az �" WA O PROVIDE 304470 NOTE: ALL SWITCHES AND RECEPTACLES TO BE 'LUTRON', "DECORA' IN COLOR SHINGLES OR PARTITION- 2' X 4"WOOD STUD WALL W/ 1/2" CDX PLYWD. EXTERIOR DOOR- 5'3"X 6'8" SINGLE FRENCH DOOR AND SIDELIGHTS WITH RAISED NEW EXTERIOR 1 SOLID BRASS HINGES &SCH LAGS HARDWARE. N LIGHT TRIMS TO BE WHITE. EXTERIOR SHEATHING (TWEK WRAPPED &TAPED), 6" EXPOSURE PERF. WD PROVIDE 304470 0 ' "ti - PROV. 1 COAT BLEACHING OIL), OIL GYP. INSUL (HIGH /TAPED) 3 2 1'-1 t" PROVIDE 8"WALL FOR 1 3' 2" IO�N.O DUPLEX ELECTRICAL RECEPTACLE � p T ( 3/4" WALL VALVE 3/4" WALL VALVE o CUR PANELING. PROV, SOLID BRASS HINGES & SCHLAGE NEW PINE I COLONIAL BASE TRIM, & D S FOIL FACE I WITH 1 (HIGH DENSITY) EXTERIOR D BRASS 311 SI S & SCHLAGE HARDWARE.HASED PAN KITCHEN VENTING 1 NEW INTERIOR PARTITION- 2" X 4"WOOD STUD WALL WITH 1/2" GYP. BD. EXTERIOR DOORS- 3'2"X 6'8" SOLID PINE DOOR WITH RAISED PANELING, 2-6" PROVIDE 8 WALL FOR 2-6' a, U (SCREWED/TAPED) APPLIED BOTH SIDES NOTE: PROVIDE MOISTURE OKITCHEN VENTING `YGFI DUPLEX RECEPLTACLE/GROUND FAULT INTERRUPT RESIST GYP. BD. (GREEN BDJ FOR ALL BATHROOM WALL AND CEILINGS. 1 - PROV. CEMENT WALL BE. FOR ALL TILE AREAS. O EXTERIOR DOOR- 28"X 6'B" STATIONARY FRENCH DOOR WITHI RAISED PANELING. SECOND FLOOR SECOND FLOOR (DSC DUPLEX SEPARATE CIRCUIT RECEPTACLE ` �-I `[ - 4 PROV. SOLID BRASS HINGES &SCHLAGE HARDWARE. a5q INTERIOR PAINT- TO BE"BENJAMIN MOORE" U.O.N ONE COAT PRIMER AND EXTERIOR DOORS- 5'4"X 6'6" PAIR FRENCH DOOR WITH RAISED PANELING. - $ WALL SWITCH w`, S TWO COATS FINISH (COLORS T.B D BY OWNER) SATIN FIN THROUGHOUT O PROV. SOLID BRASS HINGES & SCHLAGE HARDWARE MASTER BATH-SHOWER '`' MASTER BATH-SHOVWER � Zj ` N �,o U.O.N. ALL TRIM SEMI-GLOSS $3 3-WAY WALL SWITCH $4 4-WAY WALL SWITCH $s 5-WAY WALL SWITCH N Pa. f O EXTERIOR LDBRASS HING S & ARDWARE DOORS- 313" X 61811 OSCHLAGE HO RAISED PANELING PROV Tae CEILING MOUNTED JUNCTION BOX ` ;I WyWy,, R "" EXTERIOR DOORS- 4PO" X 6'11" PAIR FRENCH 00011 N S U LAT I O N NOTES : o PROV. SOLID BRASS HINGES &SCHLAGE HARDW RIEH RAISED PANELING. p a EXTERIOR DOORS-2'8" X 68" SOLID PINE DOORS WITH RAISEDI PANELING, N WALL MOUNTED JUNCTION BOX If I UFOF ti 8 S C - EXISTING EXTERIOR WALLS: 2"1 WOOD STUD R-15 HIGH DENSITY INSULATION O PROV. SOLID BRASS HINGES &SCHLAGE HARDWARE RECESSED DOWNLIGHT (100w) "LIGHTOILER"OR APPROVED EQUAL BY'CERTANTIEED' OR APPROVAL EQUAL. EXTERIOR DOORS- 316" X 618" SOLID PINE DOORS WITH RAISEDI PANELING. (z `J PROV. SOLID BRASS HINGES &SCHLAGE HARDWARE. �E EXTERIOR MOUNTED DOWNLIGHT (10OW) << �r, I BY 'CERTAINTEED' OR APPROVED EQUAL. 10 INTERIOR DOORS- 2'0" X 66" SOLD PINE DOORS WITH RAISED PANELING.PROV. SOLD BRASS HINGES & SCHLAGE HARDWARE. AS WALL MOUNTED DUAL SPOT LIGHT FE EXHAUST FAN UNIT (FLUSH) "v, � w �.;_ N, O -- NEW ROOF R-30 KRAFT-FA. INSULATION BY'CERTAINTEED' OR APPROVED EQ. INTERIOR DOORS- 2'4"X 6'8" SOLID PINE DOOR WITH RAISED PANELING 0 4" NEW CEILING MOUNTED JUNCTION BOX FOR RECESSED EXHAUST e 11 PROV. SOLID BRASS HINGES & SCHLAGE HARDWARE EP FAN/LIGHT WITH DUAL SWITCH AT WALL. "BROAN" HEAVY DUTY UNIT CRAWL SPACE R-19 KRAFT-FA. INSULATION WITH PROPER WIRE TIES OR APP. EQUAL . INSTALLED AS PER N.Y.S BUILDING CODE. INTERIOR DOORS- 261 X 6'8" SOLID PINE DOOR WITH RAISED PIANELING. .� C I 12 PROV, SOLID BRASS HINGES & SCHLAGE HARDWARE. F EXT. MOUNTED LIGHT WITH FAN w 0, NEW BASEMENT: R-10 RIGID FOAM 210" BELOW GRADE AROUND ENTIRE BASEMENT PERIMITER. INTERIOR DOORS- 2'8" X 6'B" SOLID PINE DOORS WITH RAISED PANELING. OSD SMOKE DETECTOR/CARBON MONOXIDE DETECTOR: TO BE \S t3 PROV. SOLID BRASS HINGES & SCHLAGE HARDWARE. HARD WIRED TO CENTRAL CONTROL BOX b� lb vv L 14 8� �� R' BASEMENT CEILING: R-19 KRAFT-FA. INSULATION WITH PROPER WIRE TIES aT NEW TELEPHONE RECEPTACLE INTERIOR DOOR- 3'0"X e'8" SOLID PINE DOORS WITH RAISED P,'ANELING. %G0 Nil' INSTALLED AS PER N Y S. BUILDING CODE. `.% PROV. SOLID BRASS HINGES & SCHLAGE HARDWARE `," ��y Q D CABLE TV RECEPTACLE aS.�.A . �"' AWS"" I_ INTER 75 ROV.IOSOLID BRASS HINGES & SCHLAGE HARDWARE.R DOORS- 211 X 68" SOLID PINE POCKET OR WITH PRAISED PANELING. p /� p VACUUM OUTLET (PROVIDE NECESSARY ELEC. POWER) W WINDOWLEGEND : INTERe PROV�OSR DOORS- 2-6 X SSI PAIR SOLID OLIID BRASS HINGES & SCHLAGE IHARDWARENE DOORS WITH RAIISED PANELING. BATHROOM -aps TO PROVIDED YPHOTO SENSOR OHOME OW ERNES WALL UNTED DUAL SPOT LIGHT NOTE: ALL INTERIOR CASING TO BE STANDARD COLONIAL CASING CLEAR PINE 76' X 8'0" z O UNLESS OTHERWISE NOTED. (EXISTING) W } NOTE ALL WINDOWS TO BE MARVIN WITH STANDARD MARVIN HARDWARE. ALLOW FOR EXTENSION JAMBS FOR AN 8" CONC. BLOCK WALL, W COLOR TO BE WHITE. PROV. SCREENS FOR ALL WINDOWS FLOORING LEGEND : z O ® (3 FINISH COATS OF FOAL BA SCREWEDSED TINAND GLUED.NE SUB-FLOOR-USE 3/4" 5LB. FIELT., CUDH 2424 (EGRESS) -' \\ B LAWN 2428 D CCM 2840 (EGRESS) (E)CCM 2856 (EGRESS) HARDWOOD FLOORING-SELECT WHITE OAK 2 1/4" \ FO ©CUDH 2620 OH CUDH 2620 JO CUDH 2626 OK CUDH 3024 ® CUDH 3024 w/ DIV. DNAILED. BEDROOM SUB FOR TILE AREA ©CUDH 3030 OM CUDHP 4042 O CUDHP 6062 (EXISTING) \\ LI- ©CUDHP 6858 ©CUDH 2014 ®EXISTING WINDOW ® EXISTING WOOD FLOOR TO BE SANDED & REFINISHED W/2 COATS SATIN �/l( REF. POLY. (TYP. ALL AREAS) PATCH ALL AREAS AS REQUIRED) a CERAMIC TILE- "AMERICAN OLEAW TILE OR ARE. EQ. TILE TO BE INSTALLED F F F F F ® OVER 1/2" CEMENT BOARD U.O.N WALL AND FLOOR GROUT TO HAVE PLUMBING- LEGEND : WATERPROOF ADDITIVE MIXED IN, In I 1 6" 8"I IP O PROVIDE ALL NECESSARY PLUMBING ROUGHING AND VENTING AS INDICATED L �P DII ON CONSTRUCTION PLANS) FOLLOW ALL NECESSARY N.Y.C. AND N.Y.S _ -- - - -- -- -- r BUILDING CODES THAT APPLY TO WORK BEING COMPLETED. PROV ALL - - OOM NECESSARY DRAIN VALVES BATCH RG - - -_ OF PROV. FLOOR DRAIN AND 10. GAL. SUMP ( ) O FI DGRSS N. _ HB PROVIDE FROST FREE HOSE BIBS. � — - OS SHOWER HEAD EX C J TO REMAIN 2 -III 3/ "x 1 7/ II W -- _-- --- _ __ LVL MI RO LAM REPLACE EX. - - - .- STAIR W/SAME 2 - 13/4"x91/4'' _ /AC : - HEATING -- LVL MICROLAM o„ FLOOR REGISTER p” SUPLY DUCT) - - - - - -- - -_ -- - - Z _ - _- _-- EGRESS Q Z DUCTWORK IN FLOOR BELOW — - - !I II __ TING SUBJECT OT CHANGE ! W - i EX TO MAIN (� SUPPLY REGISTER (CEILING) ) - - - ¢ III - / -" U - - Z i EX C J TO REMAIN - F' I I -- - - H R032 : X567/81H - ---- -- _ _ _ _ _ RETURN REGISTER (CEILING) 0 f1 RETURN REGISTER (WALL) — -__- - - \ d O co KITCHEN EXHAUST REGISTER (CEILING) EXO.J. T REMAIN _ - i EX. C.J. TO REMAIN, N W ^�1 - CJ O N� -- LVL MICROLAM LL MASTER BATHROOM -- -- — — — — -- Ir 15'0' X 200 I (ExIsrING) z - 2" X1 VI 10" - - HEADER --- - _ Z 0 — — — a LL D 0. � i H G 0 X.i _- -_ , SII W P -EGRESS- Z Z Z n ZDQ ¢ �I -PS K --- K ---_ K Ps W O O n — — — — OM R -- --- — — — (EXISTING)1 s iJ REMAINC TO , XH --.-_ ---- . _ -_- --- --- - - _ 0 0 0 - ° III - _ - - - - SUE EX C - N s °SII K� co 0 co -a, - z E21 X OG P ' IEp_0.IWo D r _ o X TL '— TO REMAIN— FILE NAME- FER 2CP CUR K K - --- -- - — --- --- K K K EGRESS K - - 2-28-02 K SCALE: � 1/4"=j '0" DWG NAME K K EGRESSK K SECOND FL. COILING FRAMING PLAN DWG. NO THESE DRAWINGS AS INSTRUMENTS OF SERVICE, ARE THE SOLE PROPERTY OF THE ARCHITECT SECOND FLOOR CEILING FRAMING PLAN NO REVISIONS CHANGES,AND/OR MODIFICATIONS SHALL BE ALLOWED WITHOUT WRITTEN AUTHORIZATION BYTHE ARCHITECT. ANY REPRODUCTION IN PART TOTAL SO.FT. = 2,324 OR WHOLE IS STRICTLY PROHIBITED BY LAW. I GENERAL NOTES : CONSTRUCTION LEGEND : INSULATION NOTES : PLUMBING LEGEND : ELECTRICAL LEGEND _ r� k" ORK SHALL COMPLY WITH FEDERAL, STATE, AND LOCAL BUILDING CODES � EXISTING EXTERIOR PARTITION D REMAIN. OV. 1/2" GYP. B . & R-15 HIGH EXISTING EXTERIOR WALLS: X4" WOOD STUD. R-15 HIGH DENSITY INSULATION NOTE; ALL ELECTRICAL WORK TO BE IN ACCORDANCE WITH THE RULES AND A ALL W AND ORDINANCES. DENSITY INSULATION TO ALL EXISTING EXTERIOR 'C OR WALLS. BYERTANTIEED' OR APPROVAL EQUAL. PROVIDE ALL NECESSARY PLUMBING ROUGHING AND VENTING D INDICATED REGULATIONS T THE N Y.B.F.U. ANDA CERTIFICATE FROM THE N Y.B.F.0 IS TO W P ON CONSTRUCTION PLANS). FOLLOW ALL NECESSARY COMPLETED AND N.Y.S, BE PRESENTED TO THE OWNER AT THE COMPLETION OF THE JOB u ,n �, L BUILDING CODES THAT APPLY TO WORK BEING COMPLETED PROV ALL 1� I; NEW EXTERIOR WALLS: 2"X6"WOOD STUD. R-19 FOIL FA. HIGH DENSITY INSULATOWNERION E. NECESSARY DRAIN VALVES. NOTE, THE OWNER SHALL PROVIDE ALL LIGHTING FIXTURES UNLESS OTHERWISE 1' cl 2. BEFORE COMMENCEMENT OF WORK, THE CONTRACTORS SHALL FURNISH T � EXISTING INTERIOR PARTITION TO REMAIN. PROV, t LAVER 1/2" GYP. BD. gy'CERTAINTEED' OR APPROVED EQUAL I �,WORKER'S AND ARCHITECT WITH COPIES OF ALL REQUIRED INSURANCE AND BOTH SIDES OF EXISTING WOOD STUDS. CUR. PINE 4" COLONIAL BASE TRIM. WORKER'S COMPENSATION CERTIFICATES AND NAMES OF ALL SUBCONTRACTORS. NOTED. ALL OTHER ELECTRICAL EQUIPMENT AND MAT'L. TO BE SUPPLIED BY THE NEW ROOF: R-30 KRAFT-FA. INSULATION BY'CERTAINTEED' OR APPROVED EOep PROV. FLOOR DRAIN AND 10. GAL. SUMP. ELECTRICAL CONTRACTOR. I, r s 3 THE CONTRACTORS SHALL RE RESPONSIBLE FOR ALL DIMENSIONS ANDNEW EXTERIOR PARTITION- 2" X 4"WOOD STUD WALL W/ 1/2" COX PLYWD. -'-'� CONDITIONS ON THE JOB THE ARCHITECT MUST BE NOTIFIED OF ANY VARIATIONS EXTERIOR SHEATHING (TYVEK WRAPPED &TAPED), 6" EXPOSURE PERF. WD. CRAWL SPACE: R-19 KRAFT-FA. INSULATION WITH PROPER WIRE TIES HB PROVIDE FROST FREE HOSE BIBS. NOTE: ALL SWITCHES AND RECEPTACLES TO BE 'LUTRON', "DECORA' IN COLOR tt II )"�" SHINGLES (PROV. 1 COAT BLEACHING OIL), 1/2" GYP. BD (;SCREWED/TAPED) INSTALLED AS PER N.Y S, BUILDING CODE O.N.O.. DOWNLIGHT TRIMS TO BE WHITE. FROM THE DIMENSIONS SHOWN. CUR. PINE 4" COLONIAL BASE TRIM, & R-19 FOIL FACE INSIUL. (HIGH DENSITY). , 1' U 4 THE CONTRACTOR SHALL SUPPLY ALL LABOR AN MATERIAL SHOWN ON THE NEW BASEMENT R-10 RIGID FOAM 2'O" BELOW GRADE AROUND ENTIRE *S SHOWER HEAD II C - DRAWINGS UNLESS OTHERWISE NOTED. I. NEW INTERIOR PARTITION- 2" X 4"WOOD STUD WALL WITH 1/2" GYP BD. BASEMENT PERIMITER DUPLEX ELECTRICAL RECEPTACLE C" » (SCREWED/TAPED) APPLIED BOTH SIDES. NOTE. PROVIDE MOISTURE RESIST GYP. BD GREEN BD FOR ALL BATHROOM WALL.AND CEILINGS. �GFI DUPLEX RECEPLTACLE/G ROUND FAULT INTERRUPT 5. THE CONTRACTOR SHALL 8E RESPONSIBLE FOR ADEQUATELY BRACING AND ( ) BASEMENT CEILING: R-19 KRAFT-FA. INSULATION WITH PROPER WIRE TIES PROTECTING ALL WORK DURING CONSTRUCTION AGAINST DAMAGE, BREAKAGE. PROV. CEMENT WALL BD. FOR ALL TILE AREAS. INSTALLED AS PER N Y.S. BUILDING CODE. COLLAPSE, DISTORTION, AND MISALIGNMENT ACCORDING TO ALL APPLICABLE INTERIOR PAINT-TO BE "BENJAMIN MOORE" U O.N ONE COAT PRIMER AND INC DUPLEX SEPARATE CIRCUIT RECEPTACLE . CODES. TWO COATS FINISH (COLORS T.B.D. BY OWNER) SATIN FIN THROUGHOUT N $ WALL SWITCH 6. THE CONTRACTOR SHALL $ PAY FOR AL PERMITS, FEES, AND COSTS RELATED TO U.O N. ALL TRIM SEMI-GLOSS. $a 4-WAY WALL SWITCH `0. THE WORK OF THIS CONTRACT CONTRACTORS SHALL INITIATE ALL REQUIRED a 3-WAY WALL SWITCH $s 5-WAY WALL SWITCH INSPECTIONS OF ALL WORK COMPLETED UNDER THIS CONTRACT. DOOR LEGEND : s a 7. THE CONTRACTOR SHALL AT ALL TIMES KEEP THE PREMISES CLEAN AND IS - e CEILING MOUNTED JUNCTION BOX �! RESPONSIBLE FOR REMOVAL OF ALL RUBBISH FOR ALL TRADES FROM THE JOB SITE �U NOTE: ALL INTERIOR CASING TO BE STANDARD COLONIAL CAfSING CLEAR PINE Je WALL MOUNTED JUNCTION BOX - 8 ANY"EXTRAS" FOR ALL OR LEGITIMATE UNFORESEEN CONDITIONS SHALL BE UNLESS OTHERWISE NOTED. PROV. SCREEN DOOR UNITS FOFR ALL EXT. DOORS. DOCUMENTED WITH THE COST OF APPROVAL BY OWNER OR HIS AGENT PRIOR TO RECESSED DOWNLIGHT (100W) "LIGHTOILER"OR APPROVED EQUAL jl STARTING ADDITIONAL WORK, O EXISTING DOOR TO BE REPAIRED & RE-USED. {{�� C �[ EXTERIOR MOUNTED DOWNUGHT (100W) ^ ti Q 9. DOUBLE JOISTS ARE TO BE INSTALLED UNDER ALL WALL PARTITIONS RUNNING �1c h",zv� NON PARALLEL TO THE FRAMING. PROVIDE DOUBLE HEADER JOISTS AT ALL OPENINGS, O EXTERIOR DOOR- 3'6"X 6'8" SOLID PINE DOOR WITH RAISED) PANELING. PROV. iuJB WALL MOUNTED DUAL SPOT LIGHT e REFER TO CONSTRUCT DRAWINGS FOR SIZES. 1 SOLID BRASS HINGES &SCHLAGE HARDWARE NEW CEILING MOUNTED JUNCTION BOX FOR RECESSED EXHAUST g,. �'°I le\�, 10. ALL FRAMING LUMBER TO BE DOUGLAS FIR #2 CONS.. GRADE OR BETTER. O EXTERIOR DOOR- 5'3"X 6'e" SINGLE FRENCH DOOR AND SIDELIGHTS WITH RAISED �EF FAN/LIGHT WITH DUAL SWITCH AT WALL. "BROAN" HEAVY DUN UNIT S PANELING, PROV. SOLID BRASS HINGES &SCHLAGE HARDWARE. OR APP. EQUAL I`"^` �' �S 11. THE CONTRACTOR SHALL PROVIDE SHOP DRAWINGS FOR ALL SPECIAL WORK ^ LI SUCH AS BUT NOT LIMITED TO. MILLWORK, SPRINKLER SYSTEMS AND STEEL WORK. EXTERIOR DOORS-3'2"X 6'e"SOLID PINE DOOR WITH RAISE`-D PANELING P EXT. MOUNTED LIGHT WITH FAN �y •� yx�c ! O PROV. SOLID BRASS HINGES & SCHLAGE HARDWARE. ALL SHOP DRAWINGS NEED THE APPROVAL OF THE ARCHITECT BEFORE �sD SMOKE DETECTOR/CARBON MONOXIDE DETECTOR: TO BE li� �Ny00 HARD WIRED TO CENTRAL CONTROL BOXr^" " PROCEEDING EXTERIOR DOOR-2'8"X 6'8" STATIONARY FRENCH DOOR VWITH RAISED PANELING, O4 PROV. SOLID BRASS HINGES & SCHLAGE HARDWARET NEW TELEPHONE RECEPTACLE a �` Nly d ` EXTERIOR DOORS- 5'4"X 6SI' PAIR FRENCH DOOR WITH RAISED PANELING. 4 c CABLE TV RECEPTACLE ball FLOORINGLEGEND : o PROV SOLID BRASS HINGES & SCHLAGE HARDWARE. p, VACUUM OUTLET (PROVIDE NECESSARY ELEC. POWER) EXTERIOR DOORS- 3'3"X 618"SOLID PINE DOOR WITH RAISED PANELING. W W., HARDWOOD FLOORING-SELECT WHITE OAK 21/4" 15LB. FELT , M O PROV. SOLID BRASS HINGES & SCHLAGE HARDWARE. PHOTO SENSOR SCONCES WALL MOUNTED DUAL SPOT LIGHT U '0 ® (3 FINISH COATS OF OIL BASED SATIN POLYURETHANE. EXTERIOR DOORS-4 "X 6'8" PAIR FRENCH DOOR WITH RAISED PANELING Ps TO BE PROVIDED BY HOME OWNER OO PROV. SOLID BRASS HINGES & SCHLAGE HARDWARE. Z O SUB-FLOOR-USETHICK PLYWOOD GLUED AND NAILED. } SUB FOR TILE AREEASAS TO BE SCREWED AND GLUED. EXTER DORS- 2'S" X ffff'SOLID PINE DORS WITHO PROVRISOOL DOBR SS HINGES &SCHLAGE HOARDWARE. RAISED PANELING. W o ® EXISTING WOOD FLOOR TO BE SANDED & REFINISHED W/2 COATS SATIN O EXTERIOR DOORS- 3' X 6'8" SOLID PINE DOORS WITH RAISED PANELING. /U)//'� W 6" REF. POLY. (TVP. ALL AREAS) PATCH ALL AREAS AS REQUIRED) PROV. SOLID BRASS HINGES &SCHLAGE HARDWARE V J z INTERIOR DOORS- 21011 X 618" SOLID PINE DOORS WITH RAISiED PANELING. BEDROOM_ W CERAMIC TILE - "AMERICAN OLEAN"TILE OR APP. EQ. TILE TO BE INSTALLED 10 PROV. SOLID BRASS HINGES & SCHLAGE HARDWARE, 12'6" X 176" \ © OVER 1/2" CEMENT BOARD U.O.N WALL AND FLOOR GROUT TO HAVE INTERIOR DOORS- 2'4" X 6'8" SOLID PINE DOOR WITH RAISIED PANELING. (EXISTING) WATERPROOF ADDITIVE MIXED IN. 11 PROV. SOLID BRASS HINGES & SCHLAGE HARDWARE Q O12 INTERIOR DOORS- 2'6"X 6'8"SOLID PINE DOOR WITH RAISED PANELING. PROV SOLID BRASS HINGES & SCHLAGE HARDWARE. \ Q WINDOW LEGEND_ 13 INTERIOR 0LDOORS- D BRASS HINGES & SCHLAGE HDOORS RDWAWITH RE,RAISED PANELING. E E E E EGR m ICE ALL INTERIOR CASING TO BE STANDARD COLONIAL CASING CLEAR PINE INTERIOR DOOR-310"X 618" SOLID PINE DOORS WITH RAISED PANELING. LL UNLESS OTHERWISE NOTED. 14 PROV, SOLID BRASS HINGES & SCHLAGE HARDWARE. RO 29"X 47 5/8" W NOTE: ALL WINDOWS TO BE MARVIN WITH STANDARD MARVIN HARDWARE. 15 INTERIOR DOORS-214"X 6'8" SOLID PINE POCKET DOOR WI'ITH RAISED PANELING. I[]I I ALLOW FOR EXTENSION JAMBS FOR AN 8" CONC. BLOCK WALL. PROV. SOLID BRASS HINGES & SCHLAGE HARDWARE. COLOR TO BE WHITE. PROV. SCREENS FOR ALL WINDOWS. INTERIOR DOORS-2'6"X 6'e" PAIR SOLID PINE DOORS WITH RAISED PANELING. s ® _ __ — _ _ O GE HARDWARE. o PROV. SOLID BRASS HINGES & SCHLAGE ® - F OOJO ® - � - SECOND -FLOOR CAWN 2428 CCM 840 ( GRESS)OCCM 86 (EGRESS) BATHROOM DECKBELOO, Z OCUDH 2424 (EGRESS) CUDH CUDH 6B'4" X9'4" CUDH 2626 OCUDH 3024 CUDH 3024 W/ DIV. (EXISTING) z --- -- -% JB/FAN o ©CUDH 3030 OM CUDHP 4042 ON CUDHP 6062 ©CUDHP 6858 ©CUDH 2014EO EXISTING WINDOW I�� Q T _ / ui / IIT �sD J HEATING/AC : P GE T a' Q FLOOR REGISTER (7" SUPLY DUCT) NEW UM ING C TO REPLAC DN. Z Zw ® Y 1 DUCTWORK IN FLOOR BELOW E: EXISTING. sD FE p1 W ® 1 27 z REF. J z (ROUTING SUBJECT OT CHANGE) �yj�, REF. 11 DDMP gZ I 1 D 'W Bs H.VSHOWEIR CENTER. s d3 W? \� R s1\ III l a=XNX ® SUPPLY REGISTER (CEILING) $H0 ` I AOW \\\ J \\ CH Z O C RETURN REGISTER (CEILING) ® // I GP1OW e„ p s p s, iso Js F (� RETURN REGISTER (WALL) ] a � � Q o % - - - I- - - - - - - - - - - -_ _ _ - - - - - - - - -_- -- - - - -1 0 � < KITCHEN EXHAUST REGISTER (CEILING) 1 P \ , A / I W F.C.U.Xt —1- 1 � � ® D D r __ a T 11 REF. L x � �sh ® - REP BEDROOM - — — 12'0" X 15'0" _ - `� _ 7" a^W, c 6 (EXISTING) / W a 3 EGRES� E — - - - - — a / i �I 1� ` _ OSD ¢ X p 16 / / It 0 0 9— E 1- 9—so s I 1 EF 1� C N {}�JBL JB a a ❑ E 19029" X475/8"_ - - - - 13 12 / 1 \ T � � � � � E BEDROOM 0 11 W W 0 — — O \ — 3- — — — — 11'1 O" X 156-1 I- O ❑ Z ® _3 13 — (EXISTING)SD W O O O REF. / \ REF. — - — "- - "— \ c c c ❑ ❑ o ❑ SECOND-FLOOR 7 ] D 7 _-DECK-BELOW-­ F3-0-2-1 ELOW.-- _ 3® - - m �_ db REF. ❑ N N --- w o 0 o m Q Q —__ - ._. --__._- o N 0 O N O m a FILE NAME FER_3CP_CUR 03/01/02 RO 29" X 47 5/8" S. SCALE, T C 1/4"= PO" RIFRR E E DWG. NAMI?: kLIRD F _0019 } ` PLAY I BEDROOM BEDROOY_VI DWG. NO.: THIRD FLOOR PLAN 128 X 14'10" 11'4" X 23'6" THESE DRAWINGS AS INSTRUMENTS OF SERVICE, (EXISTING) (EXISTING) ARE THE SOLE PROPERTY OF THE ARCHITECT. SH REVISIONS,WED WITH AND/OR MODIFICATIONS _-- -_— -- SHALL ARCHITECT. WITHOUT WRITTEN AUTHORIZATION BY THE ARCHITECT. ANY REPRODUCTION W PART TOTAL SQ. FT. = 1 ,830 OR WHOLE IS STRICTLY PROHIBITED BY LAW. !j N LJ IS 1--i t L UM W W , r` g LL1 H0 '; ,' ' y mo �� 'S s gg Ll Ji I - - - Ll _ W > — - +L LN- II I_� YIL IL 1 C/) L L C w 1 I I L L Cn L L 11 H FUIR - - -- - - L r I rI ALJ Y� 111 - 1 rr - � 1 J J L 1- lI I I p [� C_ JC CIIn tI — u41 CCJI J - — — - — - -- - - - - - — - - 0 YJ Jr�L] � I_ II_L,I �� 1 I_�I �L�� u� T �I IT CSI. �� J �T ` L If ICC u li L] LJ� JLJ L _I L �C]n - - � LJC LJ C I I I I � � qL J � I[=� 'J=C_ �� I � _0 _ S I J �. J 1 �1I 1-- < — � IC , � �' - - �- �C L Ji ��I `�I 1 I - H _ 11�� I `ILJI � CI 1 I _ �1„ l t 1 L TL L ���u� � Q � - - - - - `ll��� � r�I��uI I � - - T- L11 - .� Cr�JJ L L. 1 1 L II L u L JI _ w - - � I J JI � II �'ti _ - - -- J L Q � JJ L1r J� ' _' ❑ L�� __._11� ��C ❑ �_ �''� J I ❑ l[ d L _.1-I LJI�LL Jl P 1—C ",_ II_I 1 � �[JI- J I _ 11_ l�_ C II ll_I _ I 0 _ r_ J� Ir--� 11_ _Ld_JL I � ® ' T J�, IL �C � �I 1 � p a I = I - u� r� 1 �- J ,� LS uIJLw -k_ LT � _ �I Ell[ Z IT 12�11 -1 T 1 I II_ �L�L C� I ��� - r IC � � � r � ' J J �� u _ J fTY L 7 _ L a 1111 - - C f __ p r11 - III` u]_ r= J!. P ¢ Q -I - - o r � CJ � 1C� .�L� 1 � � 1 L _ �- � � _ _ ti`r i -1t�C [ 1 TL1 I- 0 ¢ ¢ I 1 LL I: a .r w a a ii D w w n 0 0 D I' Z NORTH ELEVATION 9 0 000 Wood U) A ul N_ Z) O U O N O N N O O 6 _ m FILE NAME FER_SELEV_CUR 03/01/02 SCALE: 1/4"=1 '0 ' DWG. NAME. PROPOSE D NORTH m to d : ELEVATIC N DWG NO.. THESE DRAWINGS AS INSTRUMENTS OF SERVICE, ARE THE SOLE PROPERTY OF THE ARCHITECT NO REVISIONS,CHANGES,AND/OR MODIFICATIONS SHALL BE ALLOWED WITHOUT WRITTEN AUTHORIZATION A T/A' BY THE ARCHITECT, ANY REPRODUCTION IN PART OR WHOLE IS STRICTLY PROHIBITED BY LAW u_ � 3` U II — ei � .r Qz — v N N �a a �w o •I U � Ni ,j o M al fl' \ qr 3 Zti=" °�71 i% , „ g v ez c far; V-I al p _ n WWI h4 ® I 7II - � w -- - - W — — - - - -] I, J — -- - -- Q rr— Q _ — rr =I '� -i[] f I ISL I�-� - I��� -- - W - - u � LL � ulIL - �I� = 01 - I` 111 r LIiL � I r '� '� �� � III � I � � � JII II ILI[ 10- _ - L 71_I j yi L L. �L T S u u �- IIj I �� — — — l7 _���u II �_ � � - -T rr - _ -� _ ul 7LrrI�I1_L C C L L T L J _l�- 1 -i � IIZL L W LI I LI �u_ uII II ul , - - - -_ 7 I CJP Lf - z IJ W �!� u � �' � J�I-' I1 ILJ ' U)J JI- LLL L oSI LJL o �- I a LURIE U0 Efi a• x a 0 a ¢ 0 u, 0 0 0 ¢ n. WEST ELEVATION u a a 0 0 -- 0 o m CI _GZ C J Z D 0 D R M N RI ° ° LI 7 1 co O O N Ci (n O N O I O O 1 O 1G FILE NAME FER_5ELEV_CLR 03/0'1/02 SCAL � "I/411—TO" DWG. NAME, PROPOSED WEST ELEVATION DWG. NO., THESE DRAWINGS AS INSTRUMENTS OF SERVICE, ARE THE SOILS PROPERTY OF THE ARCHITECT. NO REVISIONS,CHANGES,AND/OR MODIFICATIOPIS ^ n WALL BE ALLOWED ANY WRITTEN AUTHORIZATION A. /1 � /I BY THE ARCHITECT, ANY REPROCUOTI ON IN PART T L OR WHOLE IS STRICTLY PROHIBITED BY LAW WR5 I r- i; () N tltl V � Za pN U ' H = Ld \slg� ' LL F± III W T — -- 41 Q > rr lF Ff -- - -- -- LL -- - - - IF =uLR - -- - - - -- Q LJ - I = I_ - - - - - - - - - - - - - - - - z �p �I � - - - �1 r Cf 1LIII iIL 71 0 IYIIII ❑ �T - ❑ IIS El ■ I Lrlf ❑ ❑ ❑ ❑ lLl ❑ ❑ ❑ � IT� '� ��� �T _ _ oc I PROV 40 YEAR " ASPHALT L LII � - Z I _ T Lu ROOF SHINGLE. (TYP. ALL AREAS) - _ LJC � �T J �I_I II ' I, l _ 1L_i _ 7 �_II�I� L _1151 -IF I� - - - -- LI 11 1 1 0 W D r 0 In Ll El � i _ _..�J� O F— ❑ 1111 IL � n - II = _ II - � � I II 0 0a a aa 0 0 0 m (y Z 9 9 Z 9 m m PJ m 0 0 0 0 ❑ ❑ ❑ O W W W W 0 0 0 0 N_ 0%1 0 0_011 N N N W o 0 0 In 0 O O O 0 FILE NAME: FER_5ELE\_CUR D3/O I/)2 1 SCALE y ii 1/411_- ICM DWG. NAME : PROPO3E_D SOUTH ELEVAI ION DWG. NO THESE DRAWINGS AS INSTRUMENTS OF SERVICE, ARE THE SOLE PROPERTY OF THE ARCHITECT. NO REVISIONS.CHANGES,AND/OR MODIFICATIONS SHALL BE ALLOWED WITHOUT WRITTEN AUTHORIZATION 4�. ��.� BYTHE ARCHITECT. ANY REPRODUCTION IN PART OR WHOLE IS STRICTLY PROHIBITED BY LAW U y. il �yj � Ili u N ^. W ` u as 4 1--�i R H '.'':40W Sm BVI 4 ILIT \� LI I_ _ Ir - - - - �1 ❑ ILI - - -- � _ ® __I ❑ 11 I, III I — I I I ❑ 1 - '� ❑ r L — w LL d_IILVIII'j — =I —� V _ _II_ ❑ 1 �_I� l� �T II _ CLL IL11 T� 11 IT . -- --- ��� n 1 A a-- I I L� � C7� 0 1 ❑ '�'❑ ❑ L' 1L- ❑ L��I ® L_f I_ �I�1� �11 II 1- lit L �� I m n L�u L �fil 1 L _I L._ � �, L - — w -- r - r -- I � L I - -- -- - I L�L - RF —1 LrH EL LLL �lyL 1=1 — J d 0 u) r ' I IC❑ _ �� WIn �S tT IFN — 1I— --- -- T-u -- -`---- -- - - - --- — -- __ - a m Q f, LL 0 0 ❑ F fL 4 H a O o 0 � m EAST ELEVATION 9 o mmNm p 1] C I- I- H H O ❑ O D WWWW N O O D m FILE NAME: FER_5ELEV CUR 03/01/02 SCALE:-"' 1/4"=110 DWG NAME r PROPOSED EASZ ELEVATION 1 DWG. NO.'. THESE DRAWINGS AS INSTRUMENTS OF SERVICE, ARE THE SOLE PROPERTY OF THE ARCHITECT A. 4-4 NO REVISIONS,CHANGES,ANO/OR MODIFICATIONS /A. d L�. SHALL BE ALLOWED WITHOUT WRITTEN AUTHORIZATION BY THE ARCHITECT. ANY BEER ODUCT'pN IN PART OR WHOLE IS STRICTLY PROHIBITED BY LAW, GENERAL NOTES : CONSTRUCTION LEGEND : INSULATION NOTES : DOOR LEGEND : ELECTRICAL LEGEND : 1 ALL WORK SHALL COMPLY WITH FEDERAL, STATE, AND LOCAL BUILDING CODES NEW EXTERIOR PARTITION-2"X 6" WOOD STUD WALL W/1/2" CDX PLYWD. EXISTING EXTERIOR WALLS' 2"X4" WOOD STUD. R-15 HIGH DENSITY INSULATION NOTE' ALL INTERIOR CASING TO BE STANDARD COLONIAL CASING CLEAR PINE NOTE: ALL ELECTRICAL WORK TO BE IN ACCORDANCE WITH THE RULES AND AND ORDINANCES EXTERIOR SHEATHING TYVEK WRAPPED &TAPED), 6" EXPOSURE PERF WD BY'CERTANTIEED' OR APPROVAL EQUAL. UNLESS OTHERWISE NOTED. PROV. SCREEN DOOR UNITS FOR ALL EXT. DOORS. REGULATIONS OF THE N.Y.B.F.U, AND A CERTIFICATE FROM THE N Y B F.U. IS TO W i SHINGLES (PROV. 1 COAT BLEACHING OIL), 1/2" GYP. BD.(SCRIEWED/TAPED) BE PRESENTED TO THE OWNER AT THE COMPLETION OF THE JOB. w OUR PINE 4" COLONIAL BASE TRIM, & R-19 FOIL FACE INSUL. (HIGH DENSITY NEW EXTERIOR WALLS: 2"X6"WOOD STUD R-19 FOIL FA. HIGH DENSITY INSULATION INTERIOR DOOR-2'-4" X 6'-e" SOLID PINE DOOR WITH RAISED PANELING. 2. BEFORE COMMENCEMENT OF WORK, THE CONTRACTORS SHALL FURNISH THE m SY'CERTAINTEED' OR APPROVED EQUAL. O PROV. SOLID BRASS HINGES & SCHLAGE HARDWARE NOTE' THE OWNER SHALL PROVIDE ALL LIGHTING FIXTURES UNLESS OTHERWISE ~{ Z OWNER AND ARCHITECT WITH COPIES OF ALL REQUIRED INSURANCE ANDNOTED. ALL OTHER ELECTRICAL EQUIPMENT AND MAT'L. TO BE SUPPLIED BV THE a C) WORKER'S COMPENSATION CERTIFICATES AND NAMES OF ALL SUBCONTRACTORS NEW INTERIOR PARTITION-2"X 4"WOOD STUD WALL WITH 1/2" GYP. BD. NEW ROOF: R-30 KRAFT-FA. INSULATION BY'CERTAINTEED' OR APPROVED EQ. INTERIOR DOOR- Z-6"X 6'-e" SOLID PINE DOOR WITH RAISED PANELING. ELECTRICAL CONTRACTOR. " (SCREWEDITAPED) APPLIED BOTH SIDES. NOTE: PROVIDE MOISTURE 2 S. THE CONTRACTORS SHALL BE RESPONSIBLE FOR ALL DIMENSIONS AND RESIST GYP. BD. (GREEN BD.) FOR ALL BATHROOM WALL AND CEILINGS. CRAWL SPACE: R-19 KRAFT-FA. INSULATION WITH PROPER WIRE TIES PROV. SOLID BRASS HINGES &SCHLAGE HARDWARE. CONDITIONS ON THE JOB. THE ARCHITECT MUST BE NOTIFIED OF ANY VARIATIONS PROV. CEMENT WALL BD. FOR ALL TILE AREAS. O PAIR I SOLID BRASS HINGES AND -8" DOORLAGE HARDWARE NOTE. ALL SWITCHES AND RECEPTACLES TO BE 'LUTRON', "DECORA" IN COLOR OV FROM THE DIMENSIONS SHOWN. INSTALLED AS PER N.Y.S. BUILDING CODE. PAIR INTERIOR DOORS - 2- 2'-2" X 6'-8" DOORS WITH RAISED PANELING. O.N.O.. DOWNLIGHT TRIMS TO BE WHITE. U INTERIOR PAINT-TO BE "BENJAMIN MOORE" 110.N ONE COAT PRIMER AND NEW BASEMENT: R-10 RIGID FOAM 2'0" BELOW GRADE AROUND ENTIRE Z 8 TWO COATS FINISH COLORS T.B.O. BY OWNER SATIN FIN. THROUGHOUT DUPLEX ELECTRICAL RECEPTACLE O - 4. THE CONTRACTOR SHALL SUPPLY ALL LABOR AND MATERIAL SHOWN ON THE ( ) BASEMENT PERIM ITER. PAIR INTERIOR ASS HI - 2- S A X 6'-8"SCHLAGE HARD RAISED PANELING. U S = DRAWINGS UNLESS OTHERWISE NOTED. U,O.N. ALL TRIM SEMI-GLOSS. 4 �" O PROV. SOLID BRASS HINGES AND SCHLAGE HIARDWARE. 3 5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ADEQUATELY BRACING AND HARDWOOD FLOORING-SELECT WHITE OAK 2 1/4"%V_ 15LB. FELT., BASEMENT CEILING' R-19 KRAFT'-FA. INSULATION WITH PROPER WIRE TIES �GFI DUPLEX RECEPLTACLE/GROUND FAULT INTERRUPT I Q N U PROTECTING ALL WORK DUPING CONSTRUCTION AGAINST DAMAGE, BREAKAGE, 3 FINISH COATS OF OIL BASED SATIN POLYURETHANE. INSTALLED AS PER N.Y.S. BUILDING CODE. PAIR EXTERIOR DOORS- 2- 3-0" X 6'-e" DOORS WITH RAISED PANELING. (DSC DUPLEX SEPARATE CIRCUIT RECEPTACLE O " Z ^ - COLLAPSE, DISTORTION, AND MISALIGNMENT ACCORDING TO ALL APPLICABLE PROV SOLID BRASS HINGES AND SCHLAGE HARDWARE. SUB-FLOOR-USE 3/4"THICK PLYWOOD GLUED AND NAILED. WALL SWITCH N -Y CODES EXTERIOR FRENCH WOOD DOOR-4'-0"X 6'-e" - FWG68068L m SUB FOR TILE AREAS TO BE SCREWED AND GLUED. OPROVIDE SOLID BRASS HARDWARE BY'ANDERISONz( It w 6 THE CONTRACTOR SHALL PAY FOR AL PERMITS, FEES, AND COSTS RELATED TO ' THE WORK OF THIS CONTRACT. CONTRACTORS SHALL INITIATE ALL REQUIRED CERAMIC TILE -"AMERICAN CLEAN"TILE OR APP. EQ. TILE TO BE INSTALLED EXTERIOR FRENCH WOOD DOOR- 3'-0"X 6-B"- FWG6BO68R 3 3-WAY WALL SWITCH e , " INSPECTIONS OF ALL WORK COMPLETED UNDER THIS CONTRACT. OVER 1/2" CEMENT BOARD U.O N. WALL AND FLOOR GROUT TO HAVE PLUMBING LEGEND : 7 WATERPROOF ADDITIVE MIXED IN. PROVIDE SOLID BRASS HARDWARE BY'ANDERISON.' 7. THE CONTRACTOR SHALL AT ALLTIMES KEEP THE PREMISES CLEAN AND IS -- - B CEILING MOUNTED JUNCTION BOX -'� Ex EXISTING DOOR TO REMAIN U w RESPONSIBLE FOR REMOVAL OF ALL RUBBISH FOR ALLTRADES FROM THE JOB SITE ® PROV. ADDITIONAL 1/2" SUBFLOOR PRIOR TO INSTALLING CARPET. N" COLOR AND TYPE TO BE DETERMINED. WALL MOUNTED JUNCTION BOX + PROVIDE ALL NECESSARY PLUMBING ROUGHING AND VENTING AS INDICATED �JB e. ANY"EXTRAS" FOR ALL OR LEGITIMATE UNFORESEEN CONDITIONS SHALL BE •P ON CONSTRUCTION PLANS) FOLLOW ALL NECESSARY N.Y.0 AND N Y.S U N - DOCUMENTED WITH THE COST OF APPROVAL BY OWNER OR HIS AGENT PRIOR TO BUILDING CODES THAT APPLY TO WORK BEING COMPLETED. PROV ALL RECESSED DOWNLIGHT (100w) "LIGHTOILER" OR APPROVED EQUAL STARTING ADDITIONAL WORK NECESSARY DRAIN VALVES WINDOW LEGEND : m uuM W E EXTERIOR MOUNTED DOWNLIGHT (100W) 9. DOUBLE JOISTS ARE TO BE INSTALLED UNDER ALL WALL PARTITIONS RUNNING OF PROV. FLOOR DRAIN AND 10 GAL. SUMP. - - PARALLEL TO THE FRAMING. PROVIDE DOUBLE HEADER JOISTS AT ALL OPENINGS. de WALL MOUNTED DUAL SPOT LIGHT - F�1 PAINTING NOTES : HB PROVIDE FROST FREE HOSE BIBS. UNLESS OTHERWISE NOTED,TO BE STANDARD COLONIAL CASING CLEAR PINE FAN/LIGHT WITH DUAL SWITCH AT WALL. "BROAN" HEAVY DUN UNIT a \ � ' REFER TO CONSTRUCT DRAWINGS FOR SIZES. mQ� NEW CEILING MOUNTED JUNCTION BOX FOR RECESSED EXHAUST „ O 70. ALL FRAMING NUMBER TO BE DOUGLAS FIR #2 CONS.. GRADE OR BETTER ---- - - TEF +� �. � \,�q � w OS NOTE: ALL WINDOWS TO BE MARVIN INTEGRITY CLAD WITH STANDARD MARVIN OR APP. EQUAL a v MAN SHOWER HEAD y (; , 11. THE CONTRACTOR SHALL PROVIDE SHOP DRAWINGS FOR ALL SPECIAL WORK ALL WALLS TO RECEIVE 1 COAT PRIMER PLUS THREE COATS FINISH INTEGRITY HARDWARE, UNLESS OTHERWISE SPECIFIED. DIVIDED LITES TO BE IN SUCH AS BUT NOT LIMITED TO MILLWORK, SPRINKLER SYSTEMS AND STEEL WORK. %re PROVIDE BENJAMIN MOORE PAINTS THROUHOUT SATIN FINISH ALL ALL GLASS AREAS EXCEPT LOWER PORTIONS OF DOUBLE HUNG WINDOWS AND EXT. MOUNTED LIGHT WITH FAN ALL SHOP DRAWINGS NEED THE APPROVAL OF THE ARCHITECT BEFORE NEW WALLS AND CEILINGS WITH SEMI-GLOSS ON ALL DOORS &]TRIM SLIDING PATIO DOORS ALLOW FOR EXTENSION JAIWIBS FOR A 2"X 6" WOOD STUD F �`�,�.\`? L \ P1" L PROCEEDING. WALL. COLOR TO BE WHITE PROVIDE SCREENS FOR ALL WINDOWS. OsD SMOKE/CARBON MONOXIDE DETECTOR: S\� '�epi Y"� TO BE HARD WIRED TO CENTRAL CONTROL BOX AO CAWN3228 © IDH3440 O IDH3452 (STD MARVIN) T NEW TELEPHONE RECEPTACLE OD IDH3456 OE IDH3452-2 O SP. ORDER- 2-8"X V-0" W TRANSOM WINDOW © SP. ORDER- 4-0"X 1'-O" TRANSOM WINDOW Z W i' LIJ J SIZE FLUES AS REQUIRED. m L.L 4" BRICK CHIMNEY PROV. R-30 FIBERGLAS INSULATION IN ALL ATTIC AREAS. (Q 4" BRICK CHIMNEY EXISTING 3" X 12" RIDGE BEAM W EXISTING 3"X 10" R.R. @ 16" O C 0 PROV. FLASHED CRICKET BEHIND 7 EXISTING CHIMNEY. EXISTING 3"X 12" RI GE BEAM EX. FULL DIM 3"' X 10" C.J. @ 16" O.C. PROV. FLASHED CRICKET BEHIND L TO BE REPLACED AS NECESSARY EXISTING CHIMNEY O EX. FULL DIM. 2" X 6" W EXISTING 3" X 12" RIDGE BEAM - C.J @ 16" 0.0 NEW ASPHALT ROOF SHINGLES EXISTING DOORS AND YR HE "GAF"TIMBERLINE 30L �1/2" GYP. BD. ON ALL AND REFINISHED. OR APPROVED EQUAL L TRIM TO BE SANDED r r L EXPOSED SURFACEJ S. PROV. 1/2"COX PLYWOOD SHEATHING. _- \/) r_ ISTING FULL DIM. 2`X 4" EX. LLL DIM. 4"X 1 O" 15# FELT BENEATH ASPHALT ROOF \l SURFACES) EXISTING 3"X 10" R.R. HINGLE (@ 16" O.0 STUD WALL WO D BEAM -- I S 5 (TYP. ALL AREAS) n L I 16" O.C. EX. FULL DIM WOOD BEAM 4 X 10" W I Lu EX. 3" X 1011 FULL DIM. F J. @ 16" O.C. O <. " TO BE REPLACED AS NECESSARY Z C; EX. FULLDI M. 2" X 6" - PROV 6" GUTTERS. C JE. @ 18" O C 15�1 ® EX. FULL DIM. (/6" X 10" BEAM7a± I - R-19 FOIL FA. INSULATION.(TYPICAL ALL AREAS) /Yd PROV. R-30 FIBERGLAS I - W nI,(I INSULATION IN FLOORS - nEXISTING FULL DIM. 2"X 4" 0 0 0 0 - NEW ASPHALT ROOF SHINGLES CPROV FLASHED CRICKET BETWEEN AND CEILINGS. (TYP. ALL)PD16" O.C. STUD WALL AND REOF NEXISTING DOOORS EDD OR A�TIMBERLINE 30 YR.EXISTING CF{IMNEY AND NEW PORCH. - o� APBE PROVED EQUAL. 2"X 8" R.R. @ 16" O.C. - =Le I PROV. 1/2" CDX PLYWOOD SHEATHING Z I EX. 3"X 10" FULL DIM F.J. @ 16" O.C. I 15# FELT BENEATH ASPHALT ROOF > TO BE REPLACED AS NECESSARY SHINGLES. (TYP. ALL AREAS) $ ¢ E X12 H�R. a ' EXISTING DOORS AND _-- F � EXNH _ o 2"X 6" C.T. @ 16" O.0 = 1/2" GYP. BD. ON ALL EXISTING FULL DIM 2"X TRIM TO BE SANDED W J 3 - EXPOSED SURFACES. I @ 16" O C STUD WALL AND REFINISHED -- J m ➢ o o J Ll�1� D W DJ I 7 II I I n mN a _ 0 0 2"X 8" F.J. @ 16" O.C. 2"X 6" FULL DIM. CCA SILL PLATE EX 3" X 10" FULL DIM. F.J. @ 16"O.C. 2" X 8" F J. @ 16" O.C. 7 ° o a TO BE REPLACED AS NECESSARY PROV. R-30 FIBERGLAS fD EXISTING 4" BRICK FOUNDATION TO INSULATION IN FLOORS o a BE REPAIRED/REBUILT AS PER AND CEILINGS. (TYP. ALL) FILE NAME FOUNDATION PLAN. FER 4BS ('UH 03/01/02 �xoW SCALE' 1/4„=TO" I n ' 2f yN" DWG.^: DG. NAME'S �� j EXISTING of NORTH ELEVATION „ _ SECTION 4" P. CONC. SLAB ON DWG. NO.: CLEAN COMP. FIN. THESE DRAWINGS AS INSTRUMENTS OF SERVICE, ARE THE SOLE PROPERTY OF THE ARCHITECT. NO REVISIONS,CHANGES.AND/OR MODIFICATIONS A. 41- SHALL BE ALLOWED WITHOUT WRITTEN AUTHORIZATION BYTHE ARCHITECT, ANY REPRODUCTION IN PART OR WHOLE IS STRICTLY PROHIBITED BY LAW — GENERAL NOTES : CONSTRUCTION LEGEND : INSULATION NOTES : DOOR LEGEND : ELECTRICAL LEGEND : v� W 1 ALL WORK SHALL COMPLY WITH FEDERAL, STATE, AND LOCAL BUILDING CODES r a 04 ~ EXISTING EXTERIOR PARTITION TO REMAIN PROV. l/2" GYP BD &R-15 HIGH 04EXISTING EXTERIOR WALLS: 2"X4" WOOD STUD. R-15 HIGH DENSITY INSULATION NOTE: ALL INTERIOR CASING TO BE STANDARD COLONIAL CASING CLEAR PINE NOTE. ALL ELECTRICAL WORK TO BE IN ACCORDANCE WITH THE RULES AND � � J AND ORDINANCES. s W DENSITY INSULATION TO ALL EXISTING EXTERIOR WALLS BY'CERTANTIEED' OR APPROVAL EQUAL. UNLESS OTHERWISE NOTED PROV. SCREEN DOOR UNITS FOR ALL EXT, DOORS REGULATIONS OF THE N.Y.B.F.U. AND A CERTIFICATE FROM THE N.Y.B.F.U. IS TO NEW EXTERIOR WALLS. 2"X6" WOOD STUD R-19 FOIL FA HIGH DENSITY INSULATION BE PRESENTED TO THE OWNER AT THE COMPLETION OF THE JOB. �� @ 'Z, 1 z BEFORE COMMENCEMENT C WORK, THE CONTRACTORS SHALL FURNISH THE BY'CERTAINTEED' OR APPROVED EQUAL. > O OWNER AND ARCHITECT WITH COPIES OF ALL REQUIRED INSURANCE AND EXISTING INTERIOR PARTITION TO REMAIN. R. PI t LAYER 1/2" GYP. E O EXISTING DOOR TO BE STRIPPED, REPAIRED & RE-USED. PROV. NEW HARDWARE. NOTE: THE OWNER SHALL PROVIDE ALL LIGHTING FIXTURES UNLESS OTHERWISE WORKER'S COMPENSATION CERTIFICATES AND NAMES OF ALL SUBCONTRACTORS, BOTH SIDES OF EXISTING WOOD STUDS. CUR. PINE 4" COLONIAL BASE TRIM. NEW ROOF: R-30 KRAFT-FA INSULATION BY'CERTAINTEED' OR APPROVED EQ. NOTED. ALL OTHER ELECTRICAL EQUIPMENT AND MAT'L. TO BE SUPPLIED BY THE z U - CRAWLSPACE.PER K S BUIL INSULATION WITH PROPER WIRE TIES ELECTRICAL CONTRACTOR 3 THE CONTRACTORS SHALL BE RESPONSIBLE FOR ALL DIMENSIONS AND NEW EXTERIOR PARTITION- 2"X 4"WOOD STUD WALL W/ 1/2" CDX PLYWD. INSTALLED AS PER N Y.S BUILDING CODE. INTERIOR DOOR- 2-6"GE X 6'8" SOLID PINE DOOR WITH RAISED PANELING PROV —' CONDITIONS ON THE JOB. THE ARCHITECT MUST BE NOTIFIED OF ANY VARIATIONS n_ EXTERIOR SHEATHING (TYVEK WRAPPED &TAPED), 6" EXPOSURE PERF. WE SCHLAGE HARDWARE. O SOLID BRASS HINGES & 1 "a NEW BASEMENT: R-1 O RIGID FOAM 2'O" BELOW GRADE AROUND ENTIRE NOTEALL SWITCHES AND RECEPTACLES TO BE 'LUTRON', "DECORA" IN COLOR FROM THE DIMENSIONS SHOWN. SHINGLES (PROV. t COAT BLEACHING OIL), 1/2" GYP. BD.(SCREWED /TAPED) BASEMENT PERIMITER INTERIOR DOOR 2'4"X 6'8" SOLID PINE DOOR WITH RAISED PANELING PROVO.N.O . DOWNLIGHT TRIMS TO BE WHITE t O �. CLR PINE 4" COLONIAL BASE TRIM, & R-19 FOIL FACE INSUL (HIGH DENSITY) 2 ' k - SOLID BRASS HINGES &SCH LACE HARDWARE 4 THE CONTRACTOR SHALL SUPPLY ALL LABOR AND MATERIAL SHOWN ON THE BASEMENT CEILING' R-19 KRAFT-FA INSULATION WITH PROPER WIRE TIES O DRAWINGS UNLESS OTHERWISE NOTED NEW INTERIOR PARTITION- 2" X 4"WOOD STUD WALL WITH 1/2" GYP. BD. INSTALLED AS PER N.Y.S. BUILDING CODE 4) DUPLEX ELECTRICAL RECEPTACLE ` 300 —T' NEW IN E INTERIOR PD APPLIED BOTH SIDES NOTE: PROVIDE MOISTURE INTERIOR DOORS- PAIR 2'0"X 6'B" SOLID PINE DOORS WITH RAISED PANELING. t (' N N O PROV SOLID BRASS HINGES &SCHLAGE HARDWARE. �I. 5 THE CONTRACTOR SHALL BE RESPONSIBLE FOR ADEQUATELY BRACING AND RESIST GYP. BD. (GREEN BD) FOR ALL BATHROOM WALL AND CEILINGS. Y'GFI DUPLEX RECEPLTACLE/GROUND FAULT INTERRUPT PROTECTING ALL WORK DURING CONSTRUCTION AGAINST DAMAGE, BREAKAGE, PROV. CEMENT WALL BD. FOR ALL TILE AREAS COLLAPSE, DISTORTION, AND MISALIGNMENT ACCORDING TO ALL APPLICABLE Esc DUPLEX SEPARATE CIRCUIT RECEPTACLE @ N CODES. INTERIOR PAINT- TO BE "BENJAMIN MOORE" U.O.N. ONE COAT PRIMER AND 22-9 ' TWO COATS FINISH (COLORS T.B.D. BY OWNER) SATIN FIN. THROUGHOUT a < S. THE CONTRACTOR SHALL PAY FOR AL PERMITS, FEES, AND COSTS RELATED TO U.O.N. ALLTRIM SEMI-GLOSS T-2" 14,_3„ $ WALL SWITCH $� 4-WAY WALL SWITCH t F THE WORK OF THIS CONTRACT. CONTRACTORS SHALL INITIATE ALL REQUIRED --- - — — — —— — — — — — — — — — — — INSPECTIONS OF ALL WORK COMPLETED UNDER THIS CONTRACT $a 3-WAV WALL SWITCH $s 5-WAY WALL SWITCH F 9 �� - g O — 777 7 THE CONTRACTOR SHALL AT ALL TIMES KEEP THE PREMISES CLEAN AND ISe CEILING MOUNTED JUNCTION BOX rW W RESPONSIBLE FOR REMOVAL OF ALL RUBBISH FOR ALL TRADES FROM THE JOB SITE PLUMBING LEGEND : L J 0JB S. ANY"EXTRAS" FOR ALL OR LEGITIMATE UNFORESEEN CONDITIONS SHALL BE WALL MOUNTED JUNCTION BOX ` i U oo ry ST OF APPROVAL BY OWNER OR HIS AGENT PRIOR TO RECESSED DOWNLIGHT (100w) "LIGHTOILER" OR APPROVED EQUAL DOCUMENTED D WITH THE CO i PROVIDE ALL NECESSARY PLUMBING ROUGHING ANDVENTING A INDICA TED STARTING ADDITIONAL WORK. OR s e ON CONSTRUCTION PLANS). FOLLOW ALL NECESSARY N Y C AND N.Y.S. 1$`E EXTERIOR MOUNTED DOWNLIGHT (1 COW) 9. DOUBLE JOISTS ARE TO BE INSTALLED UNDER ALL WALL PARTITIONS RUNNING BUILDING CODES THAT APPLY TO WORK BEING COMPLETED. PROV. ALL PARALLELTO THE FRAMING. PROVIDE DOUBLE HEADER JOISTS AT ALL OPENINGS NECESSARY DRAIN VALVES. REFER TO CONSTRUCT DRAWINGS FOR SIZES de WALL MOUNTED DUAL SPOT LIGHT — F PROV FLOOR DRAIN AND 10 GAL SUMP 10. ALL FRAMING LUMBER TO BE DOUGLAS FIR ".2 CONS.. GRADE OR BETTER. k\ NEW CEILING MOUNTED JUNCTION BOX FOR RECESSED EXHAUST \ L_eF FAN/LIGHT WITH QUAL SWITCH AT WALL "BROAN" HEAVY DUN UNIT PIN 11. THE CONTRACTOR SHALL PROVIDE SHOP DRAWINGS FOR ALL SPECIAL WORK SHB PROVIDE FROST FREE HOSE BIBS OR APP EQUAL L SUCH AS BUT NOT LIMITED TO MILLWORK, SPRINKLER SYSTEMS AND STEEL WORK. EXT MOUNTED LIGHT WITH FAN ALL SHOP DRAWINGS NEED THE APPROVAL OF THE ARCHITECT BEFOREP S SHOWER HEAD PROCEEDING. SMOKE DETECTOR/CARBON MONOXIDE DETECTOR' TO BE $ !\kms.\ HARD WIRED TO CENTRAL CONTROL BOX FLOORINGLEGEND : WINDOW LEGEND : LINE OF DECK ABOVE aT NEW CABLETTELEPHONE PTACLEPTACLE - 25-3" QD CAREEN RECEPTACLE W Y HARDWOOD FLOORING-SELECT WHITE OAK 2 1/4"W , 15LB. FELT., NOTE' ALL INTERIOR CASING TO BE STANDARD COLONIAL CASING CLEAR PINE U UNLESS OTHERWISE NOTED. (1 VACUUM OUTLET (PROVIDE NECESSARY ELEC. POWER) (3 FINISH COATS OF OIL BASED SATIN POLYURETHANE. V z O NOTE: ALL WINDOWS TO BE MARVIN WITH STANDARD MARVIN HARDWARE. 6'-6" 6' T-D" 9'-8" 9'-8" 13'-1" W } SUB-FLOOR-USE 3/4"THICK PLYWOOD GLUED AND NAILED. ALLOW FOR EXTENSION JAMBS FOR AN 8" CONC. BLOCK WALL SUB FOR TILE AREAS TO BE SCREWED AND GLUED. COLOR TO BE WHITE PROV. SCREENS FOR ALL WINDOWS. - -a . . (� W WOOD FLOOR TO BE SANDED & REFINISHED W/2 COATS SATIN I _ i ._ 3'-4" ") z ® EXISTING REF POLY. (TYP. ALL AREAS) PATCH ALL AREAS AS REQUIRED) A CAWN 2432 B CAWN 2428 C CCM 2836 (EGRESS) ® ' CERAMIC TILE- "AMERICAN OLEAW TILE OR ARE. EQ. TILE TO BE INSTALLED OD CCM 2840 (EGRESS) O CCM 2856 (EGRESS) FO CUDH 2424 (EGRESS) 3._6. IIII III III III \\ ��a\, 1 LU L� OVER V2" CEMENT BOARD U.O.N WALL AND FLOOR GROUT TO HAVE e III i2 @12C0 CF(JT\A�B ABOVE 7 WATERPROOF ADDITIVE MIXED IN. OG CUDH 2620 OH CUDH 2620 JO CUDH 2626 \ �`• .�= .j CA t Il III III \ OC OK CUDH 3024 ©OUCH 3030 OM CUDHP 4042 ., HEATING/AC : CEDER 6062 OCUDHP 6854 ©CUDHP 6858 E ' : 7 6 III 6 71, < — ©CUDH 2D14 ®EXISTING WINDOW r II ggIII �IqI IIIIIIIII T' DUOOTWO KI SINEFLOOR BELOW CT) „ V.I.F. - - -_- - - -- - - - - --- - - - - - - - - --- r'�ell '—'11 1W 7jF. � i (ROUTING SUBJECT OT CHANGE) 2 8 / UP IIII Y u illtlh. LL ® SUPPLY REGISTER (CEILING) V. F r — — LINE OF DECK ABOVE R I III III III 0 III III RETURN REGISTER (CEILING) — a // 2"10" CC Fi. ABOVE III 7 8 III i2 @1X00 OFABOVE P OV� III F1 I RETURN REGISTER (WALL) T_1��� V P, -3° z -- III KITCHEN EXHAUST REGISTER (CEILING) 32'-9" V F. JBVLF0 - - - - - - - - - -- E 1A a 1'-io"�V.I.F. .... ---- II ' a "'` • I Lil ava.,r,..,...;...; ..i..�.. r - - - - - U— r- - - - - E�- - — i'—_ Lu 6O�AMP I / � I III 5 ,D I. � I III J p.� ELED PNL V. F. III 2'_6 V.I.'F. IIII _ V.I.F. 5'-6' .LFII N � - - - - - -{ - - III - - - - - - _ ChB �— ri -tl O ,3-6" I II` �� I( � i i II II �' ,� III I �— = :{ • (A � -61VLF. 0 l T1-- -�— L, Vo'F III „ ¢ 7 3, 3, v.LFI _ _ - - r – _I . I — w W 71D — ,' - - _ _ - -� � x ,' BLOCKx B" D. PEIR � III p _ ( �� 12-0" 2'x 2'x 10" D. P. CONC FTG \ / 1 r - -1 r— III — - - - - — - - - - - FJ V. .F IIII . TYR ALL X � 8' 24'_2" III N 6'_3" i —I -� I 7, , Im ¢ ¢ r ——t O O 1 E4 — OE±z lC..I IIJe�L�^-.�1'!I Itf - •;�'I.II I I —I/ I I — — — I I OJ OJ OW O Z Z Z Z 1 2"X 10" CCF . ABOVA , ®V.I.F. @iz' O O (tYP.J J D D o D II X 1 O' CCA FJ ABOVE 7_6, V.I. `" ) I , I � III 2 9 IIIIIII 7- DI s' V 3._ NoNs - - - - - - - - - - - - -- - - - - r - - - - '47- - - -- - - - - - - g - - o ���m1 :I FILENAME --- - - - - - — —'1 -fit-. ' I:-. FEE_OCP_CUR — 2" X 10" CCA FJ. ABOVE 12" X 10" CCA FJ ABOVE -SCALE. 2" X 10" CC ABOVE m ) 7'-io \\ - - / / 0,_4„ @1z" oc YP.) III @,z" o.c P. 'I/4"=y O: @12" O.0 PJ \\\\ \ / ,2" X 10" CCA FJ ABOVE T_9" 8'-9" 5'-6" \\ \ / @12' OC (TYP.) DWG NAME' FOUNDATION 1 .! — G . � t r`- - t — . �.—r . i r, , r , ..� —t � .� � PLAN 'IlI— — . ' T:®TI s I = _ _ -+ = _r G: ' l — — 10'_4" — T-3" f 10,_3„ 10,_6„ DWG. NO T-8" T-8" 8'-1 O" 5'-10" 8'-9" 5'-6" • — r r '' •- 't � •. .. -: I THESE DRAWINGS AS INSTRUMENTS OF SERVICE, A. O '--- —"- - - - LINE OF DECK ABOVE. ARE THE SOLE PROPERTY OF THE ARCHITECT NO REVISIONS,CHANGES,AND/OR MODIFICATIONS 3`6„ FOUNDATION PLAN SHALL A ALLOWED WITHOUT REPRODUCTION AUTHORIZATION BY THE ARCHITECT. LY PROHIBITED B ON W PART _ OR WHOLE IS STRICTLY PROHIBITED BY LAW o� SPRINKLER NOTES: 1 ALL NOTES BELOW PERTAIN TO NFPA 13D 1991 EDITION UNLESS OTHERWISE NOTED 2, THIS SPRINKLER SYSTEM IS HYDRAULICALLY BALANCED AS PER ACCOMPANYING CALCULATIONS AND SECTION 6-4. DESIGN CRITERIA 3 THE INSTALLATION, COMP ACING, LOCATION, POSITION AND TYPE OF SYSTEM SHALL C TO CHA ERS 4, AND 5 4. AS PER CHAPTER 3 F N PA 13 1991 EDITION, LL EQUIPMENT SHALL BE LISTED OCCUPANCY CLASS RESIDENTIAL-LT HAZARD OCCUPANCY OR OR APPROVED FOR E PROTECTION SE E / / / / / AREA OF APPLICATION 450 SF 5 SPRINKLERS ARE TO BE PROTECTED AGAINST FREEZING AND INJURY AS PER SECTION i COVERAGE PER 225 SF USE IS UNLAWFUL 4-5 41 PROPERTY OWNER IS TO MAINTAIN A MINIMUM OF 40° IN ALLAREAS OF WET PIPING SPRINKLER HEAD 6. INSPECTION AND TEST OF SPRINKLERS SYSTEM SHALL BE CONDUCTED AS SPECIFIED IN WOOD M NO CU SPRINKLERS 1 &2 WITHOUT CERTIFICATE CHAPTER 8 ORJOIST CALCULATED 7. THE OCCUPANCY OF THE AREAS TO BE SPRINKLED SHALL BE IN ACCORDANCE WITH THREADED SYSTEM DEMAND 31.49 GPM @ 41 49 psi OF OCCUPANCY @NODE SECTION 1-4-7,AND AS SPECIFIED ON PLANS SCREW ROD In,r !p^q: a^"CNEL:^s r0R 8 WATER SUPPLY TEST PIPES AND GAUGES SHALL BE PROVIDED AS SPECIFIED IN SECTION 4-6 4.2 "K" FACTOR 5 6 KAS 9 PIPING SPECIFICATIONS, SYSTEM TEST PIPES, PROTECTION AGAINST CORROSION, I�z.Ir REL ii it ESCAPE 7 4 DRAINAGE, FITTINGS, VALVES, HANGERS, GUARDS AND SHIELDS SHALL BE IN Ei(.3kSl"ED B1I k�:'�RT. 714 OF ACCORDANCE WITH NFPA 13 SWIVEL 10 STOCK OF EXTRA SPRINKLER HEAD WILL BE FURNISHED AS SECTION 2-27 (REQUIRED HA GEROOP� N.Y. $Tt�;sE ULIILDIFEG CODE. L E G E N D FOR EACH TEMPERATURE RATING). INDICATES NEW PENDANT SPRINKLER HEAD TO BE QTY 11 SPACING, LOCATION AND POSITION OF SPRINKLER HEADS WILL BE ACCORDANCE WITH • RELIABLE MODEL F4/R CONTRACTOR: CHAPTER 4, ORIFICE-1/2' K FACTOR-135- F 99 12 1"TO 12"MINIMUM CLEARANCE OF SPRINKLER DEFLECTOR TO CEILING AS PER SECTION 4-4141 13. DISTANCE OF SPRINKLER FROM HEAT SOURCES SHALL BE IN ACCORDANCE WITH TABLE TYPICAL HANGER INDICATES NEW SPRINKLER PIPING LINE GLOBAL FIRE SOLUTIONS, INC. 47 BROADWAY 4-3 1 3.2 A&B INDICATES TYPICAL HANGER LOCATION LYNBROOK, NY 11563 14 DRAINAGE TO CONFORM TO SECTION 4-63 T EVERY 10'-0"O C a WITHIN IT OF EVERY HEAD PH.. (516) 872-8466 15, ALL VALVES SHALL BE IDENTIFIED AS REQUIRED BY SECTION 2-7 3, HYDRALIC REFERENCE POINT FAX. (516) 872-8463 16 ALL VALVE CONNECTIONS TO WATER SUPPLIES AND IN THE SUPPLY TO SPRINKLERS SHALL G BE APPROVED O S &Y OR APPROVED INDICATOR TYPE AS PER SECTION 2-7.1 1, 17 DRAIN VALVES AND TEST VALVES SHALL BE APPROVED TYPE AS PER SECTION 2-72. WATER 113595988 WATER 18. HANGERS SHALL BE OF A TYPE APPROVED FOR USE WITH PIPE OR TUBE INVOLVED MAIN Cr ` IN ACCORDANCE WITH SECTION 2-6. } J 19 PROVISIONS SHOULD BE MADE TO FACILITATE FLUSHING SYSTEM PIPING BY PROVIDING ¢ y y� � FLUSHING CONNECTION CONSISTING OF A CAPPED NIPPLE 4"LONG ON THE END OF THE CROSS MAIN AS PER SECTION 4-417 18. 20 SPRINKLER HEADS SHALL BE AN APPROVED TYPE AS PER SECTION 4.3 ALL CONSTRUCTION SHALL 21, TEMPERATURE RATINGS SHALL COMPLY WITH SECTION 4-3.1 3 22. 1MINIMUM CLEARANCE TO BELOW SPRINKLER DEFLECTOR AS PER SECTION 4-4 1 6 / MEET THE REOUIREMENTSOFT I: 8" 23 UNDERGROUND PIPING IS TO BE SUPPORTED WITH RODDING, BLOCKING AND CLAMPING r - - l f - - 1 F _ _ 1- 1 F - - l F - - 1 CODES OF NEW YORK STATE. AS PER NFPA 24(1992 EDITION)REQUIREMENTS {7,m 24 CURB BOX VALVE IS TO BE PROVIDED AS PER NFPA 24(1992 EDITION) I'lIY —hIr __ _ _ _ PLUMBING 25 INTERCONNECTION OF ALARM DEVICES TO BUILDING FIRE ALARM SYSTEM SHALL BE -U4 \ ' " ALL PLUMBING WASTE BY OTHERS III III III III ,� \ &WATER LINES NEED 26, ALL REQUIRED SINAGE SHALL BE PROVIDED IN ACCORDANCE WITH NFPA — /�� APPROVED AS NOTED TESTING BEFORE COVERING 27 ALL PIPES TO BE AS FOLLOWS: MAINS 2-1/2"& LARGER TO BE BLACK STEEL SCHEDULE 10 \v _ 1 BRANCHES 2"& SMALLER TO BE BLACK STEEL SCHEDULE 40, DATE: '� 2,113 B P.N�{ �,/n�^ 7 28 ALL FITTINGS TO BE AS FOLLOWS' MAINS 2-1/2"&LARGER TO BE GROOVED TYPE FITTINGFEEBY: UNDERWRITERS CERTIFICATE - !D< < �— BRANCHES 2"& SMALLER TO BE Cl THREADED m a \\ NOTIFY BUILDING DEPARTMENT AT REQUIRED 29 "CONTRACTOR'S MATERIAL AND TEST CERTIFICATES FOR ABOVE GROUND AND(WHERE FOLLO \ 2 SAM TO 4 P FOR THE APPLICABLE)UNDER GROUND PIPE"SHALL BE SUBMITTED TO THE FIRE MARSHAL PRIOR r l r l r l F - 1 FOLLOWING INSPECTIONS: 1. FOUNDATION - TWO REQUIRED © FOR POURED CONCRETE 15 C.6Ttl';r?m gplk;in0 ig Il50Cl TO APPROVAL OF THE INSTALLATION --- - - - - - 2. ROUGH - FRAMING 8 PLUMBING E0r ,'.;,-,l_r r,",i:Yu-IETQIt4nq 1 3. INSULATION r w III IIIIII IIIIII IIIIII \IrIII STRUCTION MUST I J' ' 'G Ev41 69 - - - - - - - — FINAL � -=1 2"0 COPPER BE COMRC.O. 1"0 MAIN CONSTRUCTION MEET THE I✓i,. fRiiFkSC=RTIFICATE m o 9'-2" REQUIREMENTS OF THE CODES OF NEW IfLQJffiED YORK STATE. NOT RESPONSIBLE FOR a III SEE RISER " " DESIGN OR CONSTRUCTION ERRORS. PROVIDE ANTIAf.RI_P Aun on Je DIAGRAM SII ll - - - _-- � _-- � l — III D�IVICESIAS�TO PART. 90?.F(K) p m © ® " ' 0 PRAT 9O2F(K) � _ - - - - - - - - - - J �. � Q - 1- - - - - - - - - - - - -I IIII PLUMSER CERTIFICATION N.Y. STATE BUILDING CODE. ON LEAD CONTENT BEFORE J T - J - - � �, _ - � � _ t °RTIFICATEOFOCCUPANCY REV. DATE - = _ I I SOLDER USED IN WATER REv. DATE 12/02 3'-T 5'-11" 4'-s" s'-s" SUPPLY SYSTEM CANNOT r - - - - - .r - - - - - - - - - - - - - - - 1"0 1"0 1.,0 L J 10 / 1"0 1"0 — i 1'D T^ III III - - — —I / m m BASEMENT � a RISER UP TO IIIEXCEED 2/f00F1%LEAD. PROJECT: FIRST FLOOR ANTIFREEZE FERRARA RESIDENCE BASEMENT m ,� m III LOOP e n 11 I RISER u ro I I i 1 I I EAST MARION, NY t� Ja IIIc FIRST FLOOR �Ja � Je � 1"0"' 1110 Ak • 2 1 III 8'-10" I- - _ 7 L TITLE: r NEW YIORK STIATE & OWN CODES BASEMENT PLAN ,L _ - _ _ _ _ - J - -ii F - - 1 F_ //F_ -1 AS REO IREDANDCONDITIONSOF T__ — 4s -_11 m —11 II L � SOUTHOLDTOWN ZBA oT BASEMENT — — — — — 11 III SOUTHOLD TOWN PLANNING 80ARD — — — — — — — J m T 1'.0 1"0 N/q RISER FLOOR III - i J F - l SOUTHOLD TOWN TRUSTEES SCALE: PROJECT NO. L - - r-.c a xa THIRD FLOOR 4'-7" 4'-T AS NOTED 18 - 02 - - � I PEA AE �� � �, � °' m � —_ — �� I .v�tt`rreL N.Y.S.DEC BO"Ep M Jo 111 _ DATE:7/12/02 DWN.BY: SG III s 1110 1'0 0 J �a III �Ja �Ja 1„9 -�- - II 11'- - - - = D CKD.BY: 1"0 1'0 o� = oo III l r - - 1 r - - - E: J - - I - - - - o o - - - - _ II � II / � � T I 11 � � - - ---- - _--_- -- -/ m4 L � - _ ----- - _ III L J6 / a III III REV#1 _REVISED PER NFPA AND FM I'm f 1 0 � - OFFICE SPRINKLER HEAD LOCATION. r0 rm I I _� • 6 B' -2” 5 D' � I 9'-D" III II F „_ I r - - l r � _ — — — — --x BASEMENTm $ F _ _ 1 RISER UPTO - - - L - - - - - - - -- - - - - - FIRST FLOOR r _ - - - - - IG-,�'- - - - - - - _ - - IE.�'- - - � T III II IIII — - - - — — — — — — — — — _ - ---I I _ �� V I IIII III III III � — - - _ \ r — r — 1 1 r l r 1 1 r 1 r l r 1 \ — — — — — — — — — — — — l F l F _ = = = DFjAWING N0: . — — T — — — 7 F BASEMENT PLAN - — — --I S P 1 1/4-1' 0" NOTE 1 0 ALL SPRINKLER PIPING TO BE 1"0 CPVC PIPE APPROVED FOR RESIDENTIAL USE III � �E III � III � III III CONTRACTOR: GLOBAL FIRE SOLUTIONS, INC. III 47 BROADWAY LYNBROOK, NY 11563 PH : (516) 872-8466 III / E FAX.. (516) 872-8463 LIC# 113595988 I I UP F1 I JB 10jE E E ✓JB JB� m (V ® O� DO ..14. e.. m� / 1"0 1"0 1"0 �0 j 1 1 61 o JE 81-0.1 J�2'-10' m � 8'_2• 1 S e4 a ro 1 1� Jea 1 0 0 m / $,I q, 5'_3�� 10� D, / RISER FROM :A�aH 1"e RISER FROM BASEMENT / BASEMENT REV DATE, m q'-2.. REV 1 DATE 12/02 1"0 4'-2" PROJECT: FERRARA RESIDENCE RISER FROM EAST MARION, NY -BASEMENT I „0 1„e e TITLE: 3'-10 110 a^m FIRST FLOOR PLAN / 5'-3 10. 0” o / / ro SCALE: PROJECT NO.I F OF AS NOTED 18 - 02 TJB m m a DATE 7/12/02 DWN.BY: SG —11 CKD.BY: / 1"0 _ 1"0 / 0 / -2" 8-2 m m O O RISER FROM BASEMENT R 00 m o DEE I 1"0 1"0 1"0 1 0 5' JE DEU -10)" 3'-3" _ 9._911 1 T_3' m o � m o REV#1 _REVISED PER NFPA AND FM TOFFICE SPRINKLER HEAD LOCATION. E E E \ \a 9� 1 f V DRAWING NO: FIRST FLOOR PLAN SPIIIIIIIIIIII, 21 NOTE 1 0 ALL SPRINKLER PIPING TO BE T'0 CPCV PIPE APPROVED FOR RESIDENTIAL USE. I CONTRACTOR: GLOBAL FIRE SOLUTIONS, INC 47 BROADWAY LYNBROOK, NY 11563 PH (516) 872-8466 FAX.. (516) 872-8463 LIC# 113595988 ja — O 11.0 1110 7,*, ' — 8 2 Je 3� 2,� • 81-81, '6-2 — • }F — REV DATE i��m ,��G &}JB �� RE-- EVDATE 12/02 Ja g,, , PROJECT: mN — �3Ja 0 FERRARA RESIDENCE - -- �__ / EAST MARION NY rm m1m y - - 4' 9'' 61-51, �� J5 RISER FROM m o BASEMENT .- 7n ('"`� � .G TITLE: °iV 1'-7" Ja SECOND FLOOR PLAN 1••0 JO � r'�a _ I r,a \ TIO 1 1110 VA �_ T-2" - 8._811 • _ / SCALE. PROJECT NC. e" m s'-o" � r 6'-z" - i � m - I L AS NOTED 18 - 02 - 6O FF, o �FJe \\ iso � - I,$JB —�� _ _� DATE:?/12/02 DWN.BY: SG ------- - [IF� OJa All kit. 3'4­ m m E�, (cn� Je y - D ,..m +JE 1"0 1 0 _ a-0 —� 1 m �- REV#/ _REVISED PER NEPA AND FM I — TE==E OFFICE SPRINKLER HEAD LOCATION __ D�'Lu`re1V1'S1'a , DRAWING NO: SECOND FLOOR PLAN SPIIIIIIIIIIII, 3 NOTE 1.O ALL SPRINKLER PIPING TO BE TIO CPCV PIPE APPROVED FOR RESIDENTIAL USE. CONTRACTOR: GLOBAL FIRE SOLUTIONS, INC, 47 BROADWAY LYNBROOK, NY 11563 PH (516) 872-8466 - - --- -- - - - --- -- - FAX : (516) 872-8463 LIC# 113595988 Ell D-F-LO R 10 m T-0" 4• S.. , SSD 1 _ REV DATE -\ iso �B� � 1^) REV, 1 DATE 12102IJ }JB PROJECT. �"" TJ6 JB TJB GF _ FERRARA RESIDENCE \JB EF - JB SSE m 9 � 9 "0 T'O a EAST MARION, NY /V W e„ 4,_y�� 2�_g„ o s,_3„ a e _ 1� § r Z> e,��,� - � m m i T - I 1110 1.1 1 0 ro 1' 0 _ 1P0 O 1 _ �, ,��, , g_2.. 1 12. 3�_D" - TITLE: � ! a m -r IFO e � 1 FCU. � 9' - THIRD FLOOR PLAN s6 " L — — L — — — L� PV r._._._._._.-------------._._.J 6-0" � 1 o JB m m @ m @ m SCALE: PROJECT NO JB SD ( m�� ( � 0 i AS NOTED 18 - 02 (— rATE:7112102 DWN.BY: SG SD qo'-s'• D =Ldi �� X11 B B CKD BY: L._._._._._._._._,�._._._._._._._._ IJ D CALCULATED IIS REMOTEAREA m €n — m` L 4/j � REV#1 _REVISED PER NFPA AND FM �, SECOND FLOOR — OFFICE SPRINKLER HEAD I OCATIOPI DECK BELOW. 1 — LJ ❑ I�_ _ DRAWING NO: THIRD FLOOR PLAN SP4 NOTE 1 0 ALL SPRINKLER PIPING TO BE VO CPCV PIPE APPROVED FOR RESIDENTIAL USE i fu r FILL –P 1" 1" 0 OS&Y GATE VALVE LOCKED OPEN ESTVALV Z X L�FZZ 00 z CONTRACTOR: ��VALVEST GLOBAL FIRE SOLUTIONS, INC y- 47 BROADWAY LYNBROOK, NY 11563 PH,. (516) 872-8466 : —1" SWING CHECK HOLE FAX (516) 872-8463 DRILLED THROUGH hI CLAPPER DRAIN VALVE LIC# 113595988 NOTESSOLUTION MUST BE COMPATIBLE WITH PIPING SYSTEM F,H DETAIL 1 NON-TOXIC ANTI-FREEZE LOOP DIAGRAM NTS IT 1�llflTr Rl IIN = — - l..0 - - _ - REV DATE REV 1 DATE 12102 THIRD FLOOR PROJECT: FERRARA RESIDENCE EAST MARION, NY E0 ti � ❑❑ © - 01 TITLE: 0 CROSS SECTION 0 til z SECOND FLOOR — _ SCALE: PROJECT NO. AS NOTED 18 - 02 DATE:7/12/02 DWN.BY: SG -- _ CKD.BY: a� - „0 _ I 1..0 1110 L FIRST FLOOR 1'90 1110 CPVC REV#1_REVISED PER NFPA AND FM SPRINKLER IPE PUBLIC 2 1 OFFICE SPRINKLER HEAD LOCATION a WATER MAIN (BEYOND) (10 3 n2 BASEMENT - - - - - - - - - - " 2"0 COPPER SPRINKLER MAIN SEE DETAIL scs FOR ANTI-FREEZE SYSTEM SPRINKLER RISER DIAGRAM CROSS SECTION NTS 1 WATER FLOW SWITCH NOTE 1/4 =1 -0 2 PRESSURE GAUGE DRAWING NO: 1.0 ALL SPRINKLER PIPING TO BE 1"0 CPCV PIPE APPROVED FOR RESIDENTIAL USE 3 1"CHECK VALVE 4 1"CONTROL VALVE 5 SYSTEM DRAIN TO SAFE LOCATION SP - 5 GENERAL NOTES : CONSTRUCTION LEGEND : INSULATION NOTES : PLUMBING LEGEND_ _: ELECTRICAL LEGEND_ : r�1j ATE AND LOCAL BUILDING CODES EXISTING EXTERIOR PARTITION TO REMAIN PROV. 1/2" GYP. 8D & R-15 HIGH EXISTING EXTERIOR WALLS: 2"X4" WOOD STUD. R-15 HIGH DENSITY INSULATION NOTE' ALL ELECTRICAL WORK TO BE IN ACCORDANCE WITH THE RULES AND W W 1. ALL WORK SHALL COMPLY WITH FEDERAL. ST DENSITY INSULATION AR ALL EXISTING EXTERIOR WALLS. BY STING NTIERI OR APPROVAL EQUAL op PROVIDE ALL NECESSARY PLUMBING ROUGHING AND VENTING AS INDICATED REGULATIONS OF THE N.Y.B.F.U. AND A CERTIFICATE FROM THE N Y.B.F U. IS TO y rn ON CONSTRUCTION PLANS) FOLLOW ALL NECESSARY N.Y.C. AND N.Y.S BE PRESENTED TO THE OWNER AT THE COMPLETION OF THE JOB. BUILDING CODES THAT APPLY TO WORK BEING COMPLETED PROV. ALL z AND ORDINANCES NEW EXTERIOR WALLS' 2"X6"WOOD STUD R-19 FOIL FA. HIGH DENSITY INSULATION ' o `c 2. BEFORE COMMENCEMENT OF WORK, THE CONTRACTORS SHALL FURNISH THE EXISTING INTERIOR PARTITION TO REMAIN PROV 1 LAYER 1/2" GYP BD. gY'CERTAINTEED' OR APPROVED EQUAL NECESSARY DRAIN VALVES NOTE. THE OWNER SHALL PROVIDE ALL LIGHTING FIXTURES UNLESS OTHERWISENOTED. ALL OTHER ELECTRICAL EQUIPMENT AND MAIL. TO BE SUPPLIED BY THE U OWNER AND ARCHITECT WITH COPIES OF ALL REQUIRED INSURANCE AND BOTH SIDES OF EXISTING WOOD STUDS. CUR PINE 4" COLONIAL BASE TRIM SUMP. ELECTRICAL CONTRACTOR. WORKER'S COMPENSATION CERTIFICATES AND NAMES OF ALL SUBCONTRACTORS. NEW ROOF: R-30 KRAFT-FA, INSULATION BY'CERTAINTEED' OR APPROVED EQ. eF PROV FLOOR DRAIN AND 10 GAL WALL W/ 1/2" COX PLYWD. � F � NEW EXTERIOR PARTITION- 2" X 4"WOOD STUD NOTE' ALL SWITCHES AND RECEPTACLES TO BE 'LUTRON', "DECORA" IN COLOR 3 THE CONTRACTORS SHALL BE RESPONSIBLE FOR ALL DIMENSIONS AND EXTERIOR SHEATHING (TYVEK WRAPPED &TAPED), G" EXPOSUIRE PERF. WD CRAWL SPACE' R-19 KRAFT-FA INSULATION WITH PROPER WIRE TIES CONDITIONS ON THE JOB THE ARCHITECT MUST BE NOTIFIED OF ANY VARIATIONS SHINGLES (PROV. 1 COAT BLEACHING OIL), V2" GYP. BD (SCREWED/TAPED) INSTALLED AS PER N.Y.S. BUILDING CODE. SHB PROVIDE FROST FREE HOSE BIBS O.N.O.. DOWNLIGHT TRIMS TO BE WHITE. � Z k FROM THE DIMENSIONS SHOWN. CUR PINE 4"COLONIAL BASE TRIM, & R-19 FOIL FACE INSUL (HIGH DENSITY). O NEW BASEMENT' R-10 RIGID FOAM 2'0" BELOW GRADE AROUND ENTIRE OS SHOWER HEAD O 4, THE CONTRACTOR SHALL SUPPLY ALL LABOR AND MATERIAL SHOWN ON THE DUPLEX ELECTRICAL RECEPTACLE c U '�" DRAWINGS UNLESS OTHERWISE NOTED. NEW INTERIOR PARTITION- 2" X 4"WOOD STUD WALL WITH 1/2" GYP. BD. BASEMENT PERI MITER. ,1, (SCREWEDITAPED) APPLIED BOTH SIDES NOTE PROVIDE MOISTURE WGFI DUPLEX RECEPLTACLE/GROUND FAULT INTERRUPT � ' z SPONSIBLE FOR ADEQUATELY BRACING AND 4 � V RESIST GYP. BD. (GREEN BD.) FOR ALL BATHROOM WALL AND CEILINGS BASEMENT CEILING R-19 KRAFT-FA INSULATION WITH PROPER WIRE TIES �SC DUPLEX SEPARATE CIRCUIT RECEPTACLE O e �y ~ 5. THE CONTRACTOR SHALL BE REONSTRUCTION AGAINST DAMAGE, BREAKAGE,, PROV CEMENT WALL BE. FOR ALL TILE AREAS. INSTALLED AS PER N.Y.S BUILDING CODE -a^L "4r PROTECTING ALL WORK DURING C � COLLAPSE, DISTORTION, AND MISALIGNMENT ACCORDING TO ALL APPLICABLE V INTERIOR PAINT-TO BE "BENJAMIN MOORE" U.O.N ONE COAT PRIMER ANO $ WALL SWITCH �a q-WAY WALL SWITCH 'n CODES. TWO COATS FINISH (COLORS T.B.D BY OWNER) SATIN FIN. THRIOUGHOUT ' ' D U.O N. ALLTRIM SEMI-GLOSS. ` a 6. THE CONTRACTOR SHALL PAY FOR AL PERMITS, FEES, AND COSTS RELATED TO $a 3-WAY WALL SWITCH $s 5-WAY WALL SWITCH ) THE WORK OF THIS CONTRACT CONTRACTORS SHALL INITIATE ALL REQUIRED JB CEILING MOUNTED JUNCTION BOX DOOR LEGEND : V _ INSPECTIONS OF ALL WORK COMPLETED UNDER THIS CONTRACT 7 THE CONTRACTOR SHALL AT ALL TIMES KEEP THE PREMISES CLEAN AND ISWALL MOUNTED JUNCTION BOX , RESPONSIBLE FOR REMOVAL OF ALL RUBBISH FOR ALL TRADES FROM THE JOB SITEJB ' NOTEALL INTERIOR CASING TO BE STANDARD COLONIAL CASING (CLEAR PINE m v S. ANY"EXTRAS" FOR ALL OR LEGITIMATE UNFORESEEN CONDITIONS SHALL BE UNLESS OTHERWISE NOTED PROV. SCREEN DOOR UNITS FOR ALL EXT. DOORS. W RECESSED DOWNLIGHT (100w) "LIGHTOILER" OR APPROVED EQUAL � U o '� DOCUMENTED WITH THE COST OF APPROVAL BY OWNER OR HIS AGENT PRIOR TO ~{ D STARTING ADDITIONAL WORK. O EXISTING DOOR TO BE REPAIRED & RE-USED. �E EXTERIOR MOUNTED DOWNLIGHT (100W) .. x�a \\ WALL MOUNTED DUAL SPOT LIGHT 9. DOUBLE JOISTS ARE TO BE INSTALLED UNDER ALL WALL PARTITIONS RUNNINGJe `\. \` .\, HEADER JOISTS AT ALL OPENINGS EXTERIOR DOOR- 3'6"X 6'8" SOLID PINE DOOR WITH RAISED PANELING, PROV. PARALLEL TO THE FRAMING. PROVIDE DOUBLESOLID BRASS HINGES &SCHLAGE HARDWARE. " O NEW CEILING MOUNTED JUNCTION BOX FOR RECESSED EXHAUST REFER TO CONSTRUCT DRAWINGS FOR SIZES. EF FAN/LIGHT WITH DUAL SWITCH AT WALL. "GROAN" HEAVY DUN UNIT \ o:. EXTERIOR DOOR- 5'3"X 6'8" SINGLE FRENCH DOOR AND SIDELIGHTS WITH RAISED " a e pv 10. ALL FRAMING LUMBER TO BE DOUGLAS FIR #2 CONS.. GRADE OR BETTER. 2 OR APP. EQUAL. \�1' 1 NO O PANELING, PROV. SOLID BRASS HINGES &SCHLAGE HARDWARIE. � EXT. MOUNTED LIGHT WITH FAN ��';.�i,;b 1— i PRO SHOP DRAWINGS FOR ALL SPECIAL WORK FS`= tSai 4 11. THE CONTRACTOR SHALL P EXTERIOR DOORS- 312"X 6'8" SOLID PINE DOOR WITH RAISED PAINELING. SUCH AS BUT NOT LIMITED TO MILLWORK, SPRINKLER SYSTEMS AND STEEL WORK. O PROV. SOLID BRASS HINGES & SCHLAGE HARDWARE �sD SMOKE DETECTOR/CARBON MONOXIDE DETECTOR. TO BE \� 01\� l m ALL SHOP DRAWINGS NEED THE APPROVAL OF THE ARCHITECT BEFORE �� \ \� HARD WIRED TO CENTRAL CONTROL BOX eAV�`:'; PROCEEDING 4 EXTERIOR DOOR-2'8"X 6'8" STATIONARY FRENCH DOOR WITH RIAISED PANELING. dr NEW TELEPHONE RECEPTACLEcl r PROV. SOLID BRASS HINGES & SCHLAGE HARDWARES 0> v.L. EXTERIOR DOORS- 5'4"X 6 " PAIR FRENCH DOOR WITH RAISED (PANELING d c CABLE M '8TV RECEPTACLE FLOORING LEGEND_ : O PROV SOLID BRASS HINGES &SCHLAGE HARDWARE �y VACUUM OUTLET (PROVIDE NECESSARY ELEC. POWER) EXTERIOR DOORS-3'3"X 6'8" SOLID PINE DOOR WITH RAISED PANELING. U O HARDWOOD FLOORING-SELECT WHITE OAK 21/4"W . PROV SOLID BRASS HINGES & SCHLAGE HARDWARE.1SLB FELT., O ® HARDWOOD FINISH COATS OF OIL BASED SATIN POLYURETHANE. O EXTERIOR DOORS- 4-0' X 6ff- PAIR FRENCH DOOR H RAISED PANELING. BRASS HINGES & SCHLAGE HARDWARE. SUB-FLOOR-USE 3/4"THICK PLYWOOD GLUED AND NAILED SUB FOR TILE AREAS TO BE SCREWED AND GLUED. 8 EXTERIOR DOORS- 2'8"X 6'8" SOLID PINE DOORS WITH RAISED PANELING O PROV SOLID BRASS HINGES & SCHLAGE HARDWARE. � W EXTERIOR DOORS-3'6"X 6'6" SOLID PINE DOORS WITH RAISED PANELING "(/' z EXISTING WOOD FRLOOR TO BE SANDED ALL & AS REQUIRED)ED)REFINISHED COATS SATIN O PROV SOLID BRASS HINGES & SCHLAGE HARDWARE. ui FEE POLY. CFYP AUL- AMERICAN CUBAN"TILE OR APP. EQ TILE TO BE INSTALLED O PROV SOLID BRASS HINGES SOLID PINE DOORS WITH RAISED PANELING. BEDROOM WATERPROOF ADDITIVE MIXED IN PROV. SOLID BRASS CERAMIC TILE - " O 5 & SCHLAGE HARDWARE 12'6" 10 INTERIOR DOORS- 2 E © OVER 1/2" CEMENT BOARD U.O.N. WALL AND FLOOR GROUT TO HAVE 11 INTERIOR DOORS- 2'4" X 6'8" SOLID PINE DOOR WITH RAISED PANELING (EXISTING) HINGES & SCHLAGE HARDWARE 12 INTERIOR DOORS- 21611 X 618" HINGES & LIDPINE HLAGE HOOR ARD WITH RAISED PANELING. PROV. D BRASS WINDOW LEGEND : PROV, 13 INTERIOR R DID BRASS HINGES &SID PINE HARDWARE WITH RAISED PANELING. E E E E EGRE m�m LL NOTE' ALL INTERIOR CASING TO BE STANDARD COLONIAL CASING CLEAR PINE 14 INTERIOR DOOR- 3'0" X 6'8" SOLID PINE DOORS WITH RAISED PANELING. W UNLESS OTHERWISE NOTED. O PROV. SOLID BRASS HINGES & SCHLAGE HARDWARE, RO 29" PROV SOLID BRASS H NOTE: ALL WINDOWS TO BE MARVIN WITH STANDARD MARVIN HARDWARE. 15 INTERIOR DOORS- 2-4` X 6'8" SOLID PINE POCKET DOOR WITH RAISED PANELING HINGES & SCHLAGE HARDWARE. T ALLOW FOR EXTENSION JAMBS FOR AN 8" CONC. BLOCK WALL. a ® D COLOR TO BE WHITE. PROV. SCREENS FOR ALL WINDOWS. INTERIOR DOORS- 2'6"X 6'e" PAIR SOLID PINE DOORS WITH RAISED PANELING D _ 16 PROV. SOLID BRASS HINGES & SCHLAGE HARDWARE _ ® -SECOND-F--L-0ORRR---��� - - © CAWN 2428 OD CCM 2840 (EGRESS) EO CCM 2856 (EGRESS) BATHROOM � - �E-CK-BE- - 7 O CUDH 2424 (EGRESS)©CUDH 2620 O CUDH 2620 8'4" X 9'4" — LO (EXISTING) L JO CUDH 2626KO CU DH 3024 ®CUDH 3024 W/ DIV. - - ` I ©CUDH 3030 OM CUDHP 4042 ON CUDHP 6062 / __TF\ ©CUDHP 6858 ©CUDH 2014 EI�EXISTING WINDOW // - \\ WDI T � / ® a_ - - -- -- •SD c HEATING/AC : NEW UUMBING \ (7 o T �F LQ MT T FLOOR REGISTER (7" SUPLY DUCT) TO RE LACE Z � Z W EXISTING SDN. iso Fn Lu ® 7F mU(9 REF � \ -- III Z' DUCTWORK IN FLOOR BELOW E REF / 11 1� �� 2 a.Z O F \ _ D rL/LTJ - (ROUTINGSUBJECTOTCHANGE) s ( {y vJ Oy aWH 112 fx/1 J9 /� \\ GFI I � ^ O < ® SUPPLY REGISTER (CEILING) /f 1 / I 2QX 3' � pIJ \\ FJB // \ c Gl W 9" C.H. Z G - p O (n RETURN REGISTER (CEILING) REF. ///� I P� B P J 13 P� B _ _11 �f BD Je " RETURN REGISTER (WALL) - - - - - - - - a co KITCHEN EXHAUST REGISTER (CEILING) J / _ / _- '- - - r - � //1 L.L II GF a ® \ FC/U k1 FCU2 13 \—I' 3D4 D ❑ Ex T - - 11 - a_ // REF L L - - ED L - /_ EF. BEDROOM 3 — — — — — — — — — — — — — f — I �_ - 1 T 3•PVC O C (I 12'0" X 15'0" 1 - J - - / / 16sv $ 2 < $ (EXISTING) � 1 � 14 _ _ _ - - _ — '- - ` I T c as as T C — LL � p (ll JJ-B— JD IJ6 II I\ I \ •BD Q Q J Q RETSE \ ¢ 0 C ¢ FEER E RO 29' X475/8" \ �__ \ \ 131 m 12DB / B E BEDROOM O O Z' 11 •— ❑ ® Ds 13 D- T ® - - - _ m m C, D ® \ SID FEF / \ \ REF - 0 0 F T c 0 \ III _ ❑ D (1 ❑ c \ ECOND-F_LOO _ __ D 7 ('i 7 \ DECKEL-0\/1.-- - 0 0 U (n - 0 73 (I N 302 J. - - - _ _ ® _ - _ OW 0 O p O D 10 1 D 01 �l O FILE NAME: FER_3CP_CUR ��, 1au'aa 'vdmca� ol a3/o1/oz RO 29"X 47 5/8" s• Q" ��'.1'Yy T C iia°=11c ,, E E DWG. NAME: ""o671 R v= THIRD FLOOR , e� C I L se PLAN OPa00norn.""ea4� BEDROOM BEDROOM DWG NO 1`Z'B" THESE DRAWINGS AS INSTRUMENTS OF SERVICE. ARE THE SOLE PROPERTY OF THE ARCHITECT. THIRD FLOOR PLAN (EXISTING) (EXISTING) NO REVISIONS,CHANGES,AND/OR MODIFICATIONS /L /1 SHALL BE ALLOWED WITHOUT WRITTEN AUTHORIZATION H `{J - BYTHEARCHITECT, ANY REPRODUCTION IN PART OR WHOLE IS STRICTLY PROHIBITED BYLAW TOTAL SO. FT. = 1 ,830 3'-5 1/2" W 5 Ir - ►"'-I z FI SECTION D SECTION B17 u 1Fr kt — J 1 DN E) CEILING _ -_ _ HEIGHT = _ -I 3'5 t/2 6�_7�� 10 1/2" RUN __ _-_ 7..1.. 7•_y.. - - --- 61/2" RISEIn I-I -- - - -. yry - - __ - - -S -- - — 3 �g1..7 'pm J a' � I- - A A IIIA - 10 1/2" RUN 311 DN y SECTION C 6 1/2" RISE— k 7'-4" 14�I311C (LING HEIGHT 3'1 H i FROM 1ST STEP I, Lt t �® �i SECTION A SECTION B SECTION C � SECTION ION D SECTION A - h\ t �\ s� ti 1 1/2" RUN 6 6 1/2" RIS � vv� LLJ } - - - - BIW � W z � I I QI SECTION B- 1 SECTION B-2 N NORTH WEST w L 0I 47 42 Z 2'_9" 3'_7" p ' - W SECTION A JI SECTIONIC QI 3'_4" Z - 1 wlo _ = I 3'_6" co F I � � z I2 O O�I J 8._g.. ply 6'_4•• N q W - - - - - E W � I UO0SI CTION A SECTION C 0 - o - 0 O O _�A_L Ll 3--1 1 4'-10" Q j Iy ¢ 0 0 O 0 0 m 0 w w m w 0 9 z o m m N m o 0 0 o I — — — — — — _ ❑ ❑ 0 ❑ g7Eo04ei" D 7 7 7 �RAB�����OItIO�dOAHp�, lq N N 4 ti d�'-,�. ❑ N N N OJ N O \N\ O O O fid "` ti�:i— FILE NAME FERSTATE CUR - - ' ��� P9 06/90/02 SECTION B- 1 SECTION B-2 SCALE 1/4"=1 '011 FACING NORTH FACING WEST DWG. NAME. STATE DETAIL DWG. NO : THESE DRAWINGS AS INSTRUMENTS OF SERVICE, ARE THE SOLE PROPERTY OF THE ARCHITECT. NO REVISIONS,CHANGES,AND/OR MODIFICATIONS BE ALLOWED WITHOUT WRITTEN AUTHORIZATION A . THIRD FLOOR BY THE ARCHITECT ANY REPRODUCTION IN PART OR WHOLE IS STRICTLY PROHIBITED BY LAW GENERAL- NOTES : CONSTRUCTION LEGEND ; INSULATION NOTES : PLUMBING LEGEND : ELECTRICAL LEGEND : 1 ALL WORK SHALL COMPLY WITH FEDERAL, STATE, AND LOCAL BUILDING CODES = EXISTING EXTERIOR PARTITION TO REMAIN PROV V2" GYP BD. & R-15 HIGH AND ORDINANCES DENSITY INSULATION TO ALL EXISTING EXTERIOR WALLS EXISTING EXTERIOR WALLS' 2"X4" WOOD STUD, R-15 HIGH DENSITY INSULATION NOTE: ALL ELECTRICAL WORK TO BE IN ACCORDANCE WITH THE RULES AND w 2 BEFORE COMMENCEMENT OF WORK, THE CONTRACTORS SHALL FURNISH THE BY'CERTANTIEED' OR APPROVAL EQUAL. SP ON CONSTRUCTION PLANS). FOLLOW ALL NECESSARY IN Y.CIDE ALL NECESSARY PLUMBING ROUGHING AND .VENTINGASREGULATIONS OF THE N Y BU N.Y.S .F.0 AND A CERTIFICATE FROM THE N Y.B F . IS TO $ '� BUILDING CODES THAT APPLY TO WORK BEING COMPLETED. PRO ALL BE PRESENTED TO THE OWNER AT THE COMPLETION OF THE JOB EXISTING INTERIOR PARTITION TO REMAIN. PROV. 1 LAYER 1/2" GYP. BD. NEW EXTERIOR WALLS, 2"X6"WOOD STUD. R-19 FOIL FA. HIGH DENSITY INSULATION i OWNER AND ARCHITECT WITH COPIES OF ALL REQUIRED INSURANCE AND BY'CERTAINTEED' OR APPROVED EQUAL. NECESSARY DRAIN VALVES WORKER'S COMPENSATION CERTIFICATES AND NAMES OF ALL SUBCONTRACTORS. BOTH SIDES OF EXISTING WOOD STUDS. CLR, PINE 4" COLONIAL BASE TRIM NOTE THE OWNER SHALL PROVIDE ALL LIGHTING FIXTURES UNLESS OTHERWISE 3 THE CONTRACTORS SHALL BE RESPONSIBLE FOR ALL DIMENSIONS AND NEW EXTERIOR PARTITION- 2" X 4" WOOD STUD WALL WJ 1/2" CDX PLYWD, NEW ROOF. R-30 KRAFT-FA INSULATION BY'CERTAINTEED' OR APPROVED EQ. OF PROV FLOOR DRAIN AND 10. GAL SUMP. NOTED, ALL OTHER ELECTRICAL EQUIPMENT AND MAIL. TO BE SUPPLIED BY THE CONDITIONS ON THE JOB. THE ARCHITECT MUST BE NOTIFIED OF ANV VARIATIONS EXTERIOR SHEATHING (TYVEK WRAPPED & TAPED), '- a U 6" EXPOSURE PERF WD. ELECTRICAL CONTRACTOR. SPACE: R-19 KRAFT-FA INSULATION WITH PROPER WIRE TIES FROM THE DIMENSIONS SHOWN. SHINGLES (PROV 1 COAT BLEACHING OIL), 1/2" GYP BD (SCREWED/TAPED) INSTALLED AS PER N Y S. BUILDING CODE SHB PROVIDE FROST FREE HOSE BIBS. NOTE. ALL SWITCHES AND RECEPTACLES TO BE 'LUTRON', "DECORA" IN COLOR 1 CLR. PINE 4" COLONIAL BASE TRIM, & R-19 FOIL FACE INSUL (HIGH DENSITY). O NO.. DOWNUGHT TRIMS TO BE WHITE O '" 4 THE CONTRACTOR SHALL SUPPLY ALL LABOR AND MATERIAL SHOWN ON THE PROVIDE BASEMENT' R-10 RIGID FOAM 2'O" BELOW GRADE AROUND ENTIRE SS SHOWER HEAD e z w — DRAWINGS UNLESS OTHERWISE NOTED NEW INTERIOR PARTITION- 2" X 4"WOOD STUD WALL WITH 1/2" GYP. BD. BASEMENT PERI MITER DUPLEX ELECTRICAL RECEPTACLE 1114Ii U 5r (SCREWED/TAPED) APPLIED BOTH SIDES NOTE PROVIDMOISTURE 5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ADEQUATELY BRACING AND RESIST GYP BD. (GREEN BD.) FOR ALL BATHROOM WALL AND CEILINGS BASEMENT CEILING: R-19 KRAFT-FA INSULATION WITH PROPER WIRE TIES GFI DUPLEX RECEPLTACLE/GROUND FAULT INTERRUPT O a U N PROTECTING ALL WORK DURING CONSTRUCTION AGAINST DAMAGE, BREAKAGE. PROV. CEMENT WALL BD FOR ALL TILE AREAS COLLAPSE, DISTORTION, AND MISALIGNMENT ACCORDING TO ALLAPPLICABLE INSTALLED AS PER N Y S. BUILDING CODE CODES, INTERIOR PAINT-TO BE"BENJAMIN MOORE" U.O N ONE COAT PRIMER AND SC DUPLEX SEPARATE CIRCUIT RECEPTACLE ? m TWO COATS FINISH (COLORS T B.D. BY OWNER) SATIN FIN, THROUGHOUT N 1 6. THE CONTRACTOR SHALL PAY FOR AL PERMITS, FEES, AND COSTS RELATED TO U.O N ALL TRIM SEMI-GLOSS WALL SWITCH a 4-WAY WALL SWITCH -� 'a �n THE WORK OF THIS CONTRACT CONTRACTORS SHALL INITIATE ALL REQUIRED � 0. INSPECTIONS OF ALL WORK COMPLETED UNDER THIS CONTRACT a 3-WAY WALL SWITCH T DOOR LEGEND : 5-WAY WALL SWITCH � yr„ 7. THE CONTRACTOR SHALL AT ALL TIMES KEEP THE PREMISES CLEAN AND IS JE CEILING MOUNTED JUNCTION BOX N _ RESPONSIBLE FOR REMOVAL OF ALL RUBBISH FOR ALL TRADES FROM THE JOB SITE rT, y U q NOTEALL INTERIOR CASING TO BE STANDARD COLONIAL CASING CLEAR PINE WALL MOUNTED JUNCTION BOX r,. w a W �3 EL ANY"EXTRAS" FOR ALL OR LEGITIMATE UNFORESEEN CONDITIONS SHALL BE UNLESS OTHERWISE NOTED. PROV SCREEN DOOR UNITS FOR ALL EXT. DOORS. de Z T, DOCUMENTED WITH THE COST OF APPROVAL BY OWNER OR HIS AGENT PRIOR TO RECESSED DOWNLIGHT 100w "LIGHTOILER" OR APPROVED EQUAL Ir�y' :J o STARTING ADDITIONAL WORK ( ) '�` F_x EXISTING DOOR TO BE REPAIRED & RE-USED E L_ 9 DOUBLE JOISTS ARE TO BE INSTALLED UNDER ALL WALL PARTITIONS RUNNING EXTERIOR MOUNTED DOWNLIGHT (100W) \� a�a., II�\� PARALLEL TO THE FRAMING PROVIDE DOUBLEHEADER JOISTS AT ALL OPENINGS EXTERIOR DOOR-3'6"X 6'8" SOLID PINE DOOR WITH RAISED PANELING. PROV de WALL MOUNTED DUAL SPOT LIGHT � 'A �'y REFER TO CONSTRUCT DRAWINGS FOR SIZES. O SOLID BRASS HINGF_S & SCHLAGE HARDWARE. V \\`� NEW CEILING MOUNTED JUNCTION BOX FOR RECESSED EXHAUST vw; \iii` �'' '. 10 ALL FRAMING LUMBER TO BE DOUGLAS FIR #2 CONS GRADE OR BETTER O EXTERIOR DOOR- &16'8" SINGLE FRENCH DOOR AND SIDELIGHTS WITH RAISED er- FAN/LIGHT WITH DUAL SWITCH AT WALL "GROAN" HEAVY DUTY UNIT e- b ij�a - PANELING PROV SOLID BRASS HINGES & SCHLAGE HARDWARE OR APP. EQUAL. """V'A g'm 'I 11. THE CONTRACTOR SHALL PROVIDE SHOP DRAWINGS FOR ALL SPECIAL WORK SUCH AS BUT NOT LIMITED TO: MILLWORK, SPRINKLER SYSTEMS AND STEELWORK. EXTERIOR DOORS- 3'2"X 6'8"SOLID PINE DOOR WITH RAISED PANELING EXT MOUNTED LIGHT WITH FANF�S 4� '� R ALL SHOP DRAWINGS NEED THE APPROVAL OF THE ARCHITECT BEFORE O PROV SOLID BRASS HINGES &SCHLAGE HARDWARE A,,N;..j':\a k SID SMOKE DETECTOR/CARBON MONOXIDE DETECTOR: TO BE iy PROCEEDING HARD WIRED TO CENTRAL CONTROL BOX ",`�kE\\ffi-x�. N IN �- O EXTERIOR DOOR- 2'8"X&W STATIONARY FRENCH DOOR WITH RAISED PANELING @ \ �� PROV SOLID BRASS HINGES & SCHLAGE HARDWARE T NEW TELEPHONE RECEPTACLE a^7 j 1IM EXTERIOR DOORS- 5'4"X 6'8" PAIR FRENCH DOOR WITH RAISED PANELING. C CABLE N RECEPTACLE FLOORING LEGEND : o PROV. SOLID BRASS HINGES & SCHLAGE HARDWARE O EXTERIOR DOORS- 3'3" X 6'e" SOLID PINE DOOR WITH RAISED PANELING. Y VACUUM OUTLET (PROVIDE NECESSARY ELEC. POWER) I ' HARDWOOD FLOORING-SELECT WHITE OAK 2 1/4"W., 15LB. FELT_ PROV SOLID BRASS HINGES & SCHLAGE HARDWARE. u.l � ik (3 FINISH COATS OF OIL BASED SATIN POLYURETHANE, EXTERIOR DOORS- 4'0"X 6'8" PAIR FRENCH DOOR WITH RAISED PANELING PHOTO SENSOR SCONCES WALL MOUNTED DUAL SPOT LIGHT U SUB-FLOOR-USE 3/4"THICK PLYWOOD GLUED AND NAILED. OO PROV. SOLID BRASS HINGES & SCHLAGE HARDWARE vs TO BE PROVIDED BY HOME OWNER SUB FOR TILE AREAS TO BE SCREWED AND GLUED. O EXON EXTERIOR DOR DOORS- 08" X 6SI- SOLID PINE HINGES & SCH PAGE DOORS RDWAE RAISED PANELING. Q a ® EXISTING WOOD FLOORBE SANDED & REFINISHED W/2 COATS SATIN O PROV ISBRASS HINGES & SCHLAGE ORD ARE. W OORAISED PANELING. (T \ — REF. POLY. VP. ALL AREAS) PAA TCH ALL AREAS AS REQUIRED) OLID INTERIOR DOORS- 2'O" X 6'8" SOLID PINE DOORS WITH RAISED PANELING. BEDROOM 11 - �\ CERAMIC TILE - "AMERICAN CLEAN"TILE N APR OR TILE TOO INSTALLED 10 PRO V. SOLID BRASS HINGES & SCHLAGE HARDWARE. 126" X 17'6" 0 OVER 1/2" CEMENT BOARD U.O.N. WALL AND FLOOR GROUT TO HAVE INTERIOR DOORS- 2'4"X 6'8" SOLID PINE DOOR WITH RAISED PANELING (EXISTING) Lu WATERPROOF ADDITIVE MIXED IN. 11 EXON SOLID BRASS HINGES & SCHLAGE HARDWARE INTERR DOORS- 2'6" X 61811 12 SOLIID BRASS HINGES SCHLAGEOLID PINE DHHARDWARE OOR WITH RAISEPANELING. PROVL.L WINDOW LEGEND . INTERIOR DOORS-2'8" X 68" SOLID PINE DOORS WITH RAISED PANELING 13 PROV. SOLID BRASS HINGES 8, SCHLAGE HARDWARE E JE E E EGRE < NOTE' ALL INTERIOR CASING TO BE STANDARD COLONIAL CASING CLEAR PINE INTERIOR DOOR- 3'0" X SET' SOLID PINE DOORS WITH RAISED PANELING. IrIr OTHERWISE NOTED 14 PROV. SOUD BRASS HINGES & SCHLAGE HARDWARE. NOTE: ALL WINDOWS TO BE MARVIN WITH STANDARD MARVIN HARDWARE. INTERIOR DOORS- 2'4" X 6'8" SOLID PINE POCKET DOOR WREH RAISED PANELING, RO 29"X 47 5/8" I I ALLOW FOR EXTENSION JAMBS FOR AN e" CONC. BLOCK WALL. 15 PROV SOLID BRASS HINGES & SCHLAGE HARDWARE. u J COLOR TO BE WHITE. PROV SCREENS FOR ALL WINDOWS. 16 INTERIOR DOORS- 2'6"X 6'8" PAIR SOLID PINE DOORS WITH RAISED PANELING 73-05-1 - — - - LL O PROV. SOLID BRASS HINGES & SCHLAGE HARDWARE. ® O BO CAWN 2428 OD CCM 2840 (EGRESS) EO CCM 2856 (EGRESS) Go &I _ - 0 FO CUDH BATHROOM 2424 (EGRESS)©CUDH 2620 OH CUDH 2620 T X 9'4" - -DE--GK-RECON /`\L JO CUDH 2626 KO CUDH 3024 ®CUDH 3024 W/ DIV. (EXISTING) _ ©CUDH 3030 OM CUDHP 4042 ON CUDHP 6062 0 ©CUDHP 6858 OQ CUDH 2014 E� EXISTING WINDOW m� I L.L WEr WHEATING/AC :EM 7" FLOOR REGISTER (T' SUPLY DUCT)DUCTWORK IN FLOOR BELOW ZZ W(ROUTING SUBJECT OT CHANGE) N U WED 17 / gZ REF. _ D Z I I ® SUPPLY REGISTER (CEILING) JLLZ JdF O `+' O 171 RETURN REGISTER (CEILING) GIUXjOW 0 , < WD ZH s. F h ��_g„ C.H. RETURN REGISTER (WALL) REF. �I Z - - - - - - - — - - - - — So — �I[]II o Dmcn KITCHEN EXHAUST REGISTER (CEILING) IT T r — — — X2 nnuery — — — — — — — — — — — J U L.� < FWD-1 FCU *1 3 4 WO /� W BEDROOM REE. 13 D — — — — — — — — 1—�/— L -- – L REF— (EXISTING) J O16 GRESGl W WLL E V _ 13 REF ® G>I O O O E E P.I(I 0 N CL LL li D RO 29" X475/81' 12 E E BEDROOM d a ® ® (EXIST Z D D Z REF. / ® 1 � - _- - - - - - W J j Z REF. - - - U N 0 O O 1') 0 -- - -�SECOND_F_LOQR- — O 0 O D 302 DECK-BE-LO 0 Wj 0 c Fv7m - N 0 N co REF. W O o 0 0 w m � m •t N 0 0 o a FILE NAME FER 3CP CUR X029"X475/8" e. /01/02 SCALE E E ��e��,ewn000�rvol�eiepyk. 1/411 , ➢.III r Jc a DWG NAME : THIRD FLOOR PLAID BEDROOM BEDROOM DWG. NO , THIRDFLOOR PLAN 12'8" 11'4” X 23'6" THESE DRAWINGS AS INSTRUMENTS OF SERVICE, (EXISTING) (EXISTING) ARE THE SOLE PROPERTY OF THE ARCHITECT - - - NO REVISIONS,CHANGES,AND/OR MODIFICATIONS TOTAL SQ. FT. = 1 ,830 BYTIHEARCHITT ARCHITECT. WITHUT ANY RO PRODUCTIOWRITTENN N P AR2ATION A. 3 OR WHOLE IS STRICTLY PROHIBIT I ED BY LAW