Loading...
HomeMy WebLinkAbout49742-Z Of toulyo`o Town of Southold * P.O. Box 1179 �0 53095 Main Rd °Zrcouxrr ' Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 46609 Date: 10/23/2025 THIS CERTIFIES that the building COMMERCIAL Location of Property: 64500 CR 48 Greenport, NY 11944 Sec/Block/Lot: 40.-3-5 Conforms substantially to the Application for Building Permit heretofore, filed in this office dated: 04/14/2021 Pursuant to which Building Permit No. 49742 and dated: 09/20/2023 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: "As built" seasonal Cabin #9 in existing campground as applied for per ZBA#7384SE dated 8/20/2020. The certificate is issued to: HNF Resorts LI LLC Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: C-20-0055 7/23/2025 ELECTRICAL CERTIFICATE: 49742 07/21/2025 PLUMBERS CERTIFICATION: Jorge Naranjo 04/04/20 utho iz S ature suFEot� TOWN OF SOUTHOLD, BUILDING DEPARTMENT TOWN CLERK'S OFFICE coSOUTHOLD, NY $ BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 49742 Date: 9/20/2023 Permission is hereby granted to: . HNF Resorts LI LLC PO BOX 89 Greenport, NY 11944 To: (cabin #9) legalize "as built" seasonal cabin in existing campground as applied for per ZBA, Planning & SCHD approvals. Replaces 46356. At premises located at: 64500 CR 48, Greenport SCTM #473889 Sec/Block/Lot#40.-3-5 Pursuant to application dated 4/14/2021 and approved by the Building Inspector. To expire on 3/21/2025. Fees: PERMIT RENEWAL $512.60 Total: $512.60 J Building Inspector SUFFOR, TOWN OF SOUTHOLD �oo� may BUILDING DEPARTMENT z TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 46356 Date: 6/4/2021 Permission is hereby granted to: HNF Resorts LI LLC 690 Queen St Greenport, NY 11944 To: (cabin #9) legalize "as built" seasonal cabin in'existing campground as applied for per ZBA, Planning & SCHD approvals. At premises located at: 64500 CR 48, Greenport SCTM #473889 Sec/Block/Lot#40.-3-5 Pursuant to application dated 4/14/2021 and approved by the Building Inspector. To expire on 12/4/2022. Fees: AS BUILT-COMMERCIAL ADDITIONS/ALTERATIONS $975.20 CO-COMMERCIAL $50.00 Total: $1,025.20 Building Inspector OF SO!/j�Ql � o Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 G • Southold,NY 11971-0959 �Q BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: HNF Resorts LI LLC Address: 64500 CR 48 CABIN 9 City: Greenport St: NY Zip: 11944 Building Permit#: Section: Block: Lot: WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: Soundview Electrical License No: 57478ME SITE DETAILS Office Use Only Indoor rv—� Basement I— Service Solar F Outdoor F71 1st Floor rV I Pool r Spa I— Renovation F 2nd Floor F Hot Tub r Generator Survey 1— Attic 110 Garage Battery Storage INVENTORY Service 1 ph N Heat Duplec Recpt 31 Ceiling Fixtures 5 Bath Exhaust Fan 1 Service 3 ph F Hot Water Gas GFCI Recpt 2 Wall Fixtures 3 Smoke Detectors 2 Main Panel A/C Condenser 1 Single Recpt Recessed Fixtures CO Detectors Sub Panel 100A A/C Blower 1 Range Recpt Ceiling Fan Combo Smoke/CO 1 Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 8 4'LED Exit Fixtures Other Equipment: Fridge, Micro Notes: Cabin 9 Inspector Signature: X Date: July 21., 2025 Sean Devlin Electrical Inspector sean.devlina_town.southold.ny.us 64500CR49Cabin9 ZZ Town Hall Annex 54375 Main Road a' �• Telephone(631)765.1802 o:- P.O:.Box 1179 Southold, NY 11971-0959: ti �� ®l ark BUILDING DEPARTMENT �= r TOWN OF SOUTHOLD APR 4 2025 CERTIFICATION Date: Oy— 09 ZOO 1-5 Building Permit No. `� . 41 9� 4 2— Owner: H N Tr- (Please print) Plumber: �0-f 0.'� V\ 0 lease print) I certify that the solder used in the water supply system contains less than 2/10 of 1%lead. (Plumber afore) Sworn to b ore me this '�� A . day of f 20 ADVENDIZO TORRES NOTARY PUBLIC,STATE OF NEW YORK Notary Public, A?V4County Registration No. 01T06231053 la Qualified in SUFFOLK County Commission Expires 11/22/2026 1 OF SO(/Tyolo n /�^ # # TOWN OF SOUTHOLD BUILDIN6 DEPT. o►�� 631-765-1802 INSPECTION [ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) { ] CODE VIOLATION [/ ] PRE C/O [ ] RENTAL REMARKS: DATE 7 INSPECTOR ho�aoF Sol/ryOlo L �N�OF Ll �TO SOUTHOLD BUILDING .DEPT. Comm��`' 631-765-1802 (��1 n INSPECTION [ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: C DATE INSPECTOR C� SOUTyolo TOWN OF SOUTHOLD BUILDING DEPT. rourm, �o 631-765-1302 INSPECTION -- FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] I LATION/CAULKING [ ] FRAMING /STRAPPING [ FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REM RKS- "A914 awl lvylvCX,,00vmit,1 0 4z) r� I 4 DATE - INSPECTOR SOUTyo # � TOWN OF SOUTHOLD BUILDING DEPT. � 631-765-1802 INSPECTION . [ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INS TION/CAU.LKING [ ] FRAMING /STRAPPING [ INAL ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PR 0- [ ] RENTAL REMARKS: r r v9v oar" Az vl-\c , E it 6 W. INSPECTOR #DOE SOUTyo# .TOWN OF SOUTHOLD BUILDING DEPT. � coum, 631-765-1802 INSPECTION [ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] IN ATION/CAULKING [ ] FRAMING /STRAPPING [ FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT.CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] ' RENTAL REMARKS: tl ' DATE INSPECTOR SOl/Ty�<o * # TOWN OF SOUTHOLD BUILDING DEPT. � 631-765-1802j( � INSPECTION . [ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH P G. [ ] FOUNDATION 2ND [ ] IN ATION/CAULKING [ ] FRAMING /STRAPPING [ FINAL . [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ]. FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL . 1 REMARKS: ,*, -5 (m �`AA, kl nN . t �15 &IRSin vl�"LA 4 70 al� 'F7 L000l 2T�E INSPECTOR OF SOGTyO `# TOWN OF SOUTHOLD BUILDING DEPT. Cou 631-765-1802 INSPECTIO N FOUNDATION 1ST/ REBAR ROUG G b [ ] FOUNDATION 2ND [ ] I LATION/CAULKING ] FRAMING /STRAPPING [ FINAL [ ] FIREPLACE &CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: s Q! Y1L -;,, e � - . w,friArVI lo!-) � r yz�r L- 1 1 �1�✓` DATE ( wz INSPECTOR ti Condon Engineering, P.C. New York State Licensed Professional Engineers 1755 Sigsbee Road 631-298-1986 Mattituck,.New York 11962 Fax 631-298-2651 condoneng i neeri ng.com October 14, 2021 E C 0 u D OCT 1 9 2021 Mr. Mike Verity BUILDING DEPT. Chief Building Inspector TOWN OFsOUMOLD Southold Town Building Department 53095 Route 25 P.O. Box 1179 Southold, New York 11971 Re: Eastern Long Island Camp Ground Cottage Footings-690 Queen g1ceet Greenport. Permit#s 46347, 46348, 46349,46350, 46351,46353, 46354,4635 46356 457, 46358, 46359, 46360, 46361, 46362,46363, 46364, 46365, 46366, 46367 Dear Mr. Verity: I inspected the sono tubes footings on the property for the proposed cottagers and found them ----- r --==to=be-installed-in-accordance--with-the-plans-filed-with-the-Building_Department.The-.sono-tubes-_-__.-___.__-_.-_-_--.. were found to be properly installed and filled with concrete. To the best of my knowledge the sono tubes are installed in accordance with New York Building Code standards. If you have any questions, please call me at 631-298-1986. Yours truly, 0 ondon, P.E. � o `�'�` 051684 ���' Condon Engineering, P.G. New York State Licensed Professional Engineers 1755 Sigsbee Road 631-298-1986 Mattituck, New York 11952 Fax 631-298-2651 condonengineeri ng.com V November 25, 2021 V� 0 2p25 Mr. Mike Verity Chief Building InspectorSouthold 53095 Route 256uilding Department �� � �soo P.O. Box 1179 Southold, New York 11971 Re: Eastern Long Island Camp Ground Cottages-690 Queen Street, Greenport Dear Mr. Verity: I inspected the framing and strapping installed in the Pavilion,and cottages#1,#2.#3,#4, #5,#6,#7,#8,#9,#10,#11,#12,#13#14,#15,#16,#17,#18 and#19 were found to be installed as shown on the plans. If you have any questions, please call me at 631-298-1986. Yours truly, of NEw? na, ��A 051684 � Thomas P. Walsh,Architect, P.C. 700 Veterans Memorial Highway, Suite CL-140 Hauppauge, NY 11788 Phone: 631-348-4500 Fax:631-348-4509, Date:1019124 Town of Southold-Fire Marshal Town Hall Annex 54375 Main Road, P.0.Box 1179, Southold, NY 11971 I�! Subject: Eastern Long Island Camp Ground, 690 Queen St,Greenport, NY 11944 To whom it may concern, This letter shall serve to certify that all of the units 1-19& the Pavilion were tested at 2001bs fora period of 2 hours and there was no change in pressure. This test was witnessed by Gregory E.Sulger and Thomas P. Walsh.All of the lines have since been filled with glycol for freeze protection. Therefore, a water flow test cannot be conducted without compromising the system.A manual test was performed on all of the water flow switches.All alarms are active. Very my yours Th as P. 0#Now LIC#019767 Condon Engineering,~ P.C. ' New York State Licensed Professional Engineers 1755 Sig 6����9��bee�oo� Fax Mack, �New oondonenginaering.com \ n � November 27. 2O24 � DEC — 4 9024 — Mr. Mike Verity Chief Building Inspector Southold Town Building Department 53O95 Route 25 P.O. Box 1170 Southold, New York 11S71 ' Re: Eastern'Long Island Camp Ground Cottage Footings-690 Queen Street, Greenport Dear Mr. Verity: \ inspected the plumbing in the Pavilion, and cottages#4,#S,#6,#7,#8,#9,#11,#12,#1O and#19. The piping was found to be installed as shown on the plans and to have no leakage.The installation was found to be installed as shown on the plans. To the best ofmy knowledge the plumbing was installed in accordance with building code standards. |f you have any questions, please call mootO31-388-1S88. Yours truly, OF 051684 esslowV- Condon Engineering, P.C. New York State Licensed Professional Engineers 1755 Sigsbee Road 631-298-1986 Mattituck, New York 11952 Fax 631-298-2651 condonengineering.com l� to January 31, 2025 E A. F E B - 3 2025 Mr. Mike Verity Chief Building Inspector Southold Town Building Department 095 Route 25 P.O. Box 1179 Southold, New York 11971 Re: Eastern Long Island Camp Ground Cottages-690 Queen Street, Greenport Dear Mr. Verity: I inspected the installed insulation at the site.The insulation in the Pavilion, and cottages#4, #5,#6,#7,#8,#9,#11,#12,#18 and#19 were found to be installed as shown on the plans. To the best of my knowledge the insulation was installed in accordance with building code standards. If you have any questions, please call me at 631-298-1986. Yours truly, OF NEB 051684 �����$slrj\ ��t. 'r North Fork Cottages 8t RV Resort BUR Job Name: Installing Company: Boss Systems rmyCurrent 6 st XR150/XRSSO SERIES STANDBY BATTERY POWER CALCULATIONS Standb ^k tt ' , NaGOrrettt o- s. TOA1mA i p Qty." a,.ftlAr' S y '£ c TOtalIM+ XR1 SO/XR550 Series Control Panel 1 X 174 = 174 - 1 X 217 = 217 v _ Relay Outputs`.1-2,(ON)r 0?, X 0 10 ;, 30._. ,, 0 '30 Switching Grounds 3 6(ON) 0 X 5 0 0 X 5 0 AdveZoriesl 64., ' 1 ;1 : X 2 Active Zones 9-10 0 X 4 - 0 0 X 30 0 2-Wire Smokes 0. s. 0,. X' 0 0 t X 0.1 -0 0 Panel Bell Output(1500 mA max) Aux'powerdevicesanTermmals7and11;(Ottier4hankeypadsandLX=6usinodulei) ;,0` X?_ ;t ` D 0..•:1= "rX ... 2W-BLX,2WT-BLX Smoke Detectors 0RX 15 = 0 0 X 35 0 263LTE•Celiular Cominurncator, -:263LTE-FN Cellular Communicator 0 6 - 0 0 X 7 = 0 277�BunerModule 630F Remote Fire Command Center 0 63 - 0 0 X 92 = 0 7830fFireCommendKeypad '.. r 0, 0; -10 n. ,708 Bus Extender 0 10 - 0 0 X 10. = 0 710'Bus Splitter/Repeater Module ' - 711 Zone Expansion Module 0 X 11 = 0 - 0 X 11 = 0 Active Zone(EOLlnstalted); =. :0.'> ;=X 'u 0;,-• 0. X 2. - 0 7115 Zone Expansion Module - 0 X 4.2 = 0 0 X 4.7 = 0 712-8Tone Ezpaniion Module U. X;' 17 - -0- ;;;0 X. .. 17 0 Active Zones(EOL Installed) 0 X 1.6 - 0 0 X 2 = 0 714 Zone Expansion Module,,.,'. _ 0. X.. 7;. - 0 0 : X 7. 0 Active Zones(EOL Installed) 0 X 1.6 - 0 0 X 2 = 0 714j8,'714=16 Zone Ekpansion_Module 0 X. `.". :;20, yq 0. V X ' 20.`:" 01 Active Zones(EOL Installed) 0 X 1.6 - 0 0 X 2 = 0 715'Zone Ezpansiorr.Module " -0 X' Z, 0 0"' R 7 0 dz .. .,r; Active Zones(EOL Installed) 0 X 4 - 0 0 X 30 = 0 t2-Wire'Smokes, 0" X 0 - b _ X A.1 0, 715-8,715-16 Zone Expansion Modules 0 X 20 - 0 0 X 20 = 0 Active Zones(EOLlnstaAed) 0" ,X1 0• )',; . 0 X . 30., 0•' 2-Wire Smokes 0 X 0.1 = 0 0 X 0.1 - 0 716 Output Expansion Module 0 -X:, 13. ='d 0' ' '0 X `13 0:. \ Active Form C Relays 0 X - 0 0 X 12 = 0 717,Gra0hieAnnunciator Module; w>`e :0 X. ;..-10 0 -: t'.0 0 Annunciator Outputs 0 X - 0 0 X 1 = 0 734 Wiegand lnterface.Module '.i. :. " ,_ .•., . ..r :. u.. 0 -..X 40.' ? "•.S .0•. ` 0 '. .aX.f ?60 Active Zones(EOL Installed) 0 X 1.6 - 0 0 X 2 ' - 0 Annunciator(ON) „.: 0, X::} 0 -0 X 20 0' „"i a i Proximity Reader 0' X 200 - 0 0 X 200 _ 0 736P_'P,,OPIT,Interface Module•'., z 0.. <Q X 25 3 0.:" ' Radionics Popex,Octopopit,Popits 0 X - 0 0 X = 0 736V V,plex Module 0. X:.: A5; -- °0. . '0. .X 45, 0 . Active Zones 0 X = 0 0 X - 0 738A Ademco Wireless Interface Module 0 X 75 - 0 0 X 75 0 738T Wireless Translator 0 X 50 = 0 0 X 50 = 0 738Zplus Z-Wave Interface Module 0 X 40 - 0 0 X 40 _ - 0 763 Wi-Fi Module 0 X 31 = 0 0 X 31 = 0 1860 Relay Output Module,one relay active_ 0 X 34 __ 0 __ 0 X 34 _ = 0 a a - All four relays active 0 X 138 - 0 0 X 138 = 0 855`StyleY..ofZNotificatloti;Modute " `0 C-''„ ;26;',,, - _ '0 0 X wi 85 0:,- :- 1 866 Style W Notification Module 0 X 45 - 0 0 X 76 = 0 867 q-,Btis St&W Ngtifkatloo,Module '; ,, 0: X-' '3D;- - 0 0 s.<,:X_ 6., 869 Dual Style D Initiating Module 0 X 25 - 0 0 X 75 = 0 893ADua!'Phone Line Module. :,;- t` rsw: c.,, 0.,. X ._.... 1100X Wireless Receiver 0 X 25 - 0 0 X 35 - 0 _ .1100XH Wireless High Power Reci�ver a 0' X .i 75 0 0 X :=102, Q 7060/7160 Thinline/7060A Aqualite Keypad 0 X 72 - 0 0 X 87 = 0 7063(7:}53Ttiiniine/7063A "VaNteKe ad 0 `.y 'A", jr>I, ;:}00a: p:s s .. A�1 - .yP ...1.. ,-,,<La. .i', •zi.. 7070/7170 Thinline/7070A Aqualite Keypad 0 X 72 = 0 0 X 87 = 0 Active Zones'(EOL installed3 '_4 .,, t. 0. a 707317173 Thinline/7073A Aqualite Keypad 0 X 85 = 0 0 X 100 = 0 " _Aetive Zories(EOL Installed)_ " 0; X;:, A. - 0 0, `:X 2 0 7872 Graphic Touchscreen Keypad 0 X 145 - 0 -0 X ~215 = 0 -ActWeZorie;(EOLInstali'ed) : -. .x, 0 X' 1.6- ., 0, 0 rrX 7873 Graphic Touchscreen Keypad 0 X 143 - 0 0 X 243 = 0 - "Active2ones'(EOLlnstaBed) E Q X 1`.6 v 0.,F 8860 Graphic Touchscreen Keypad 0 X 300 - 0 0 X 350 - 0 - AuK:Pgwered Devices `:, i' K u< tri Xie. 0, 0 1 =X, c 300 ±' 300 a. ; Aux.Powered Devices 0 X = 0 0 X - 0 0 Aux.Powered Devices 0 X - 0 0 X = 0 Aux Powered Devices, 0 Aux.Powered Devices - 0 X = 0 0 X = 0 Aux Powered Devices t"'` "."' .: .. .` " 3( 0 0:, z u. Y Aux.Powered Devices 0 X - 0 0 X - 0 Aux Powered Devices > 0 X Based on 10%active zones in alarm -Total Standhy fto 1' Z00 4 Required Minimum Alarm Time in minutes t„->: _" 5 Minutes X Total Alarm mA 539 = Total Required Alarm Current 44.917 mAh 1? Total Standby mA 200.4 mA Num6erjofstandby.hoursneeded Total number of standby mA hours = 4810 mAh Totafret}uired alaFm current(ioundedy ,,_ _'+ - 95 triAh Total number of mA hours = 4855 mAh ,,.... _ :. 1 Contingcrgcy factor `+ - Total number of mAh = 5826 mAh ,_ p .'Corwett mAh to Ah. , .. .. ,, 1000,hs, c,r ti,. .r„..�,-.-1--,..^� k � -^ra.-^""`7"",""�"--^•a•r�-r-n^.-'T--r� � •--•---�.-r +,i r '�, -�--=r-- za 4 �s Battery Aliap hoWtc tegidrea For more information,refer to the Standby Battery Selection section of the XR150/XR550 Series Installation.Guide(LT-1233). This spreadsheet calculator has not been evaluated by UL. XRJ 50 XR5;0 Page 2 of 3 OFFICE LOCATION: �rj� SU(/)y MAKING ADDRESS: Town Hall Annex O� �� P.O. Box 1179 54375 State Route 25 ~ Southold,NY 11971 (cor.Main Rd. &Youngs Ave.) Southold,NY Telephone:631 765-1938 ' p�C www.southoldtownny.gov . l��at►t�'1,�� 1,7 ii ' October 22, 2025 PLANNING BOARD OFFICE TOWN OF SOUTHOLD O CT 2025 L_.�/ Ms. Patricia C. Moore, Esq. 51020 Main Road Southold, NY 11971 Re: Approved Amended Site Plan for Eastern Long Island Kampground Cabins 64500 CR 48, Greenport SCTM#1000-40.-3-5 Dear Ms. Moore: The Planning Board has found that the requirements of the above-referenced Amended Site Plan have been completed based on the site inspections made September 14, 2025 and October 10, 2025; and, the Planning Board work session on'-October 20, 2025. The approved structures and associated improvements are in general conformance with the approved amended site plan entitled "Eastern Long Island Kampground" prepared by John J. Condon P.E., dated December 16, 2019, and last revised September 24, 2020. Contingent upon the site's.continued compliance with all applicable provisions of the Town Code, the Planning Board supports the issuance of a Certificate of Occupancy by the Building Department. . This letter does not condone any changes from the approved site plan and approvals from other agencies; Planning Board approval is required prior to any significant changes to the site. If you have any questions regarding this Site Plan.or its process, do not hesitate to contact this office. Respectfully, Brian A. Cummings Senior Planner cc: Michael Verity, Chief Building Inspector Sean Magnuson, Owner FIELD INSPECTION REPORT DATE COMMENTS , FOUNDATION(IST) y ------------------------------------ T FOUNDATION(2ND) S� z � o O y ROUGH FRAMING& t PLUMBING W kA r INSULATION PER N.Y. y STATE ENERGY CODE 4 o C� FINAL ADDITIONAL COMMENTS Z ► 23 �oK a(. �'i,r-e. rr 1 O(of'�S" (ok Ck, r'' Mb Cur- - a.ve- -6 Jek t.,, r a5_ ro J �J o �z r D � _ b H o`PSufFot,r�oG TOWN OF SOUTHOLD—BUILDING DEPARTMENT y Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone(631) 765-1802 Fax(631) 765-9502 hops://www.southoldtowm.gov Date Received C EF),FV'/ ;,APPLICATION FOR BUILDING PERMITI1� P For Office Use Only APR 1 4 2021 PERMIT NO. `CC.(� Building Inspector: x y i Applications and farms must be filled out in their entirety}Incomplete s d `" ' " applications will not be accepted "Where"the AppUcantis not th'e owner;ari Owner's Authonzat1on farm n(Page 2)shall be completed` Date:4/12/21 OWNERS)OF PROPERTY UNI� # Name:HNF RESORTS INC. SCTM#1000-40.-3-5 Physical Address:690 QUEEN STREET, GREENPORT,_NY 11944 Phone# 631-477 0022 nA r.. Email:INFO ELIKAMPGROUND COM____.-r._, Mailing Address:690 QUEEN STREET GREENPORT NY 19944 CONTACT PERSON f z Name:SEAN MAGNUSON Mailing Address:SAME AS ABOVE Phone#:631-953-3899 Email: DESIGN PROFESSIONAl,INFORMATIO•f� � # � s � L Name:CONDON ENGINEERING Mailing Address:1755 SIGSBEE RD.MATTITUCK, NY Phone#:631-298-1986 Email:CONDONENG@OPTONLINE.NET - ✓ a € r � a , P CONTRACTORINFORIVIATION' ' Name:SEE ATTACHED Mailing Address: Phone#: Email: DESCRIPTION O PROPOSED GONSTitUCT10Rl TW BEDROOM jCABIN i i S i ®New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated cost of Project: ❑Other $ Will the lot be re-graded? ®Yes El No Will excess fill be removed from premises? Dyes ®No 1 -1 0 i � ,PROPERTY IN�ORMgTION � ' Existing use of property:TOU RIST CAMP Intended use of property:TOU RIST CAMP Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to RR-RESORT/RECREATION this property? ®Yes ❑No IF YES, PROVIDE A COPY. ❑:Check BOX After Reading The ownerjcontractor/design professional is responsible for ap drainage and storm water Issues as provitled by Chapter 236 of the Town Code APPLICATION iS HEREBY MADE to the Bwlding Department for the issuance of a Building Permit pursuanfto the Builtling Zone. Ordinance ofthe Town of Southold,Suffolk,County,New Yotk and other applicable laws'Ordinances or Regulations,for the construction of bwfd�hgs addltions,alterations or for removal or demoliUoq;es herein descrtbetl'.The epplicarit agrees to comply with all apphca_ble laws,ortlmances,building code, housing cod horised inspectors on p"pmises and in buildings)for Necessary inspections Faise'statements made fiere in are, pumshabie'as a class A misdemeanor pursuant to Section 210 45 of the New York State Penal Application Submitted By(print name): /�` � �,(>/� BAuthorized Agent []Owner Signature of Applicant. Date: ........... STATE OF NEW YORK) CONNIE D.BUNCH SS: Notary No.O I BUtate of 6185050 w York COUNTY OF ) Qualified in Suffolk County Commission Expires April 14,2.9nq being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing c ntract)above named, (S)he is the #&Z4 (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. 1� Sworn before me this nb dhY of 20Q Notary Public PROPERTY OWNER AUTHORIZATION (Where the applicant is not the owner) SEAN MAGNUSON residing at 825 QUEEN STREET, GREENPORT, NY EILEEN WINGATE, QUIET MAN STUDIO do hereby authorize to apply on my behalf to the Town of Southold Building Department for approval as described herein. -rl� ,ell—-- 4/13/2021 Ow er's Signa a Date S MA USON Print Owner's Name 2 BOARD MEMBERS $ X\ ly Southold Town Hall Leslie Kanes Weisman,Chairperson 53095 Main Road•P.O.Box 1179 Patricia Acampora Southold,NY 11971-0959 Eric Dantes COS N Office Location: � Robert Lehnert,Jr.. Town Annex/First Floor, 54375 Main Road(at Youngs Avenue) Nicholas Planamento ��UIIITI,� Southold,NY 11971 http://southoldtownny.gov ZONIhIG BOARD OF APPEALS TOWN OF SOUTHOLD n ;t May 19, 2021 5 ; i Tel.(631)765-1809•Fax(631)765-9064 Eileen Wingate Quite Man Studio MAY 2.0 2021 2805 West,Mill,Road, . Mattituck;NY 11952 'C CEP ', RE: Request for De.lV fmmus Determination , "AppeafNo 7384SE,'HNp`Resorts; 69.A Queen Street, Greenport SGTM No. 1.00040-3-5 Dear Ms. Wingate; I am to receipt of your correspondence,dated May,.11, 021, requestingAli a de minimus determination in!the: above referenced Zoning Board of A": "Is::Speciat Exception Permit'and Area �1arYanee decision: In.yout letto-,you requesf a de minitrius approval for a Special Exception and Area Variane6:to:construct 20 . seasonal use cabins which exceed the m xtr�um:square feet in area iri accordance wtth.the ToWi Code,upon,: an extstmg:carripground, You explain that upon'recominei datiou of'the TowA's:Planning Board,tl}at.the revised site plan depicts a re locatiott'of the cabins in order.to.preserve as many trees as,possille,and that the number of cabins have been reduced to 19." urthernzore,you Mated`that the cabYn re locations ineet.ail - zoning requirements pursuabt::tb Chapter 253 of the Town Code. Based upon the information provided','!have determined that your request is de minimus in nature because . the changes do not increase the degree of non-conformity,and tlie.decision continues to follow the general . £° standards governing Special.Exception Uses. Please be advised that'conditions set forth in Appeal No. 1384SE still apply. We ask that you submit to our *, office two amended signed and stamped surveys/site plans depicting the aforementioned changes, Contact our office if you have any further questions or.concerns. I will instruct the office to send a copy of this letter to the Building Department and the Planning,Department. leshe y, anes Weisman Chairperson cc: Michael Verity, Chief Building Inspector Heather Lanza, Planning Director BOARD MEMBERS OF SOOT Southold Town Hall Leslie Kanes Weisman,Chairperson. 53095 Main Road•P.O.Box 1179 Southold,NY 11971-0959 Patricia Acampora � � Office Location: Eric Dantes Cn Town Annex/First Floor, Robert Lehnert,Jr_ G-�`c� l�• �oQ 54375 Main Road(at Youngs Avenue) Nicholas Planamento Southold,NY 11971 Milo httpJ/southolotownny.gov RECEIVED ZONING BOARD OF"APPEALS Al 3 Q� TOWN OF SOUTHOLD . . AUG' 2 5 2020 Tel.(631)7654809•Fax(631)765-9064 lout lei Town Clerk FINDINGS,DELIBERATIONS AND-DETERMINATION MEETING OF AUGOST-2012020 ZBA FILE No.:7384SE. NAME OF APPLICANT: IMW Resorts Inc PROPERTY LOCATION: 690 Queen Street, Greenport,NY SCTM No. 1000-40-3-5 SERA DETERMINATION: The Southold Town Zoning.Board of Appeals declared Lead Agency. status for the SEQRA.review of.the special exception application and An uncoordinated review was conducted. It was determined:that.Jhis is an Unlisted Action'pursuant:to State Environmental.Quality .. Review Act(SEQRA)6:NYCRR,Part'6.17; as it does not meet any.of the thresholds of.a Type.1 Action; not does"it meet any of the criteria on.the Type II-list of actions and that the Southold Town'Zoning Board of Appeals,pursuant to SEQRA,hereby-made a.determination of non significanee for the proposed action . and grants a Negative Declaration. SUFFOLK,COUNTY ADMINISTRATIVE CODE: This application was referred-as required.under the Suffolk-County Administrative Code Sections 'A.14-14 to 21, and the Suffolk County Department of Planning issued its reply dated January 24, 2020 stating that this application is considered a matter for local determination as.there appears to be no significant county-wide or inter-community impact. LWRP DETERMINATION: The relief, permit, or interpretation requested in this application is listed under the Minor Actions exempt list and is-not subject to review under Chapter 268. TOWN OF SOUTHOLD PLANNING BOARD: The Planning Board offered comments on this application in their June 24, 2026 memorandum. The Planning Board generally has no objection to the Special Exception and cabin size due to the fact that the existing site and.use thereof received Special Exception approval in 1976 and Site Plan approval in 1976 and 2005. The Planning Board currently has- . not.endorsed a Site Plan for this proposal and reserves the right to make any necessary changes to the Site Plan after reviewing all proposals thoroughly. PROPERTY FACTS/DESCRIPTION: Subject property consists of 23.61 acres located in the Resort Residential (RR)Zoning District. The property is a campground with both mobile&tent sites currently available. The property is improved with an office/bathroom facility, sites for mobile homes, and tent camping sites. BASIS OF APPLICATION: Request for Special Exception per Code Section 280-35B(5) and Town Code Article 1, Section 253-1, the applicant is requesting permission to alter the existing Tourist and Page 2,August 20,2020 #7384SE;HNF Resorts,Inc. SCTM No. 1000-40-3-5 Trailer campground'by removing twenty(20)tent sites.and constructing twenty:(20)seasonal cottage`s,`as well as variances for twenty (20) cottages measuring 504 sf where the code only allows cottages to measure a maximum of 450 SF in size; located at: 64500 County Rd 48,Greenport SCTM# 1000-40-3-5 VARIANCE RELIEF REQUESTED: The applicant's proposal was amended to convert 33 existing tent camping sites to 20 seasonal use cabins.of approximately 504 sq. ft. with an exterior covered porch, where only 450'sq. ft. cabins are allowed. The cabin floor plans also depict a 90 sq.ft. covered.porch to be attached to the cabins for an overall size of 594 sq. ft.. In addition, a 600 sq. ft. pavilion with an . exterior deck will also be constructed. ADDITIONAL INFORMATION: The proposed 20 cottage sites are a reduction of the currently 33 existing tent."sites. There are certificates of occupancy for all of the-existing campground buildings & inground swimming..p6 1 The current site:plan was approved in 20.06, and allows for 63 seasonal RV sites, 90 short term:RV/Pop Up sites, and 33 tent sites. The site plan also approves 186 parking spots with an 80-car overflow. 'The original campground&trailer park came about from a Special Exception permit approval ZBA file#2147 dated July 22, 1976. A Letter of No-Jurisdiction was issued by the New York State Department of.Conservation (NYSDEC) indicating that no permit is required from the agency, but advised that no construction, .disturbance,. clearing or sedimentation of any kind may take place within 100 feet of NYS regulated freshwater wetlands without a permit. SPECIAL EXCEPTION: FINDINGS OF FACT/REASONS FOR BOARD ACTION: The Zoning Board of Appeals held a public hearing on this application on August 6,2020 at which time written and oral evidence were presented. Based upon all testimony,documentation,personal inspection of the property and surrounding neighborhood,and other evidence,the Zoning Board finds the following facts to be true and relevant and makes the following findings: The Board has reviewed the General Standards governing Special Exception uses set forth in Section 280- 142 and finds: A. That the use will riot prevent the orderly and reasonable use of adjacent properties or of properties in adjacent use districts..The subject property has legally existed as a tourist camp since 1976 without adverse impacts B. That the use will not prevent the orderly and reasonable use of permitted or legally established uses in the district wherein the requested use is located or of permitted or legally established uses in adjacent use districts.No new uses are being proposed in.this application C. That the safety, the health,the welfare,the comfort, the convenience or the order of the town will not be adversely affected by the proposed use and its location. The proposed cabins will meet all county sanitary regulations and will be serviced by Suffolk County Water and Greenport Village Sewer System. The site is readily accessible to fire and police protection. --- -- D—T-hat-the-use-will-be-in-harmony2Mth-and-promote-the-gener-al-purposes-and-intent ef-this----- chapter. The cabins will be in compliance with the Town's storm water management code 'Page 3,August 20,2020 #7384SE,HNF Resorts,Inc. SCTM No. 1000-40-3-5 E. That the use will be compatible with its surroundings and with the character of the neighborhood and of the community in general,.particularly with regard to visibility, scale and overall appearance. The property is screened from the road, and is adjacent to Moore's Woods. F. That all proposed structures, equipment-and material shall be readily accessible.for fire and police protection.The existing unimproved road will be widened for better fire and police access and the . campground has its own fire emergency plan and fire truck on site G.That the proposal shall comply with the requirements of Chapter23.6,Stormwater Management In making such determination,consideration was also given to: A. The character of the existing and probable development of uses in the district and the peculiar suitabilityof,such district for the location of any of such permitted uses. B. The conservation of property values and the encouragement of the most appropriate uses of land. C. The effect that the location of the proposed use and the location that entrances and exits may have upon the creation or undue increase.of vehicular.traffic congestion on public streets,highways or sidewalks.to assure the public safety. D. The availability of adequate and proper public or private water supply and facilities for the treatment;removal o�r.discharge of sewage,refuse or other effluent(whether liquid, . .solid,gaseous or otherwise)`that may be caused or created`byor as a result of.the'use. E. Whether the use or the materials incidental thereto or produced thereby may give.off obnoxious gases, odors,smoke or soot. F: :Whether the use will cause disturbing emissions of electrical discharges,dust,light, vibration or noise. G. Whether the operation in pursuance of the use will cause undue interference with the orderly enjoyment by the public of parking or of recreational facilities, if existing or if proposed by the Town or by other competent governmental agencies. H. The necessity for bituminous-surfaced space for purposes of off-street parking of vehicles incidental to the use and whether such space is reasonably adequate and appropriate and can be furnished by the owner of the plot sought to be used within or adjacent to the plot wherein the use shall be located. I. Whether a hazard to life, limb or property because of fire,flood, erosion or panic may be created by reason of or as a result of the use or by the structures to be used therefor or by the inaccessibility of the property or structures thereon for the convenient entry and operation of fire and other emergency apparatus or by the undue concentration or assemblage of persons upon such plot. J. Whether the use or the structures to be used therefor will cause an overcrowding of land or undue concentration of population. K. Whether the plot area is sufficient, appropriate and adequate for the use and the reasonably anticipated operation and expansion thereof. L. Whether the use to be operated is unreasonably near to a church,school,theater, recreational area or other place of public assembly. ---------K—Whether-the-site of-the-pr-oposed-uses particularly-sui#able-fo-r-such-use -- - --------- -N. Whether adequate buffer yards and screening can and will be provided to protect adjacent properties and land uses from possible detrimental impacts of the proposed use. Page 4,August 20,2020 #7384SE,HNF Resorts,Inc. SCTM No, 1000-40-3-5 O. Whether adequate provision can and will be made for the collection and disposal of stormwater runoff, sewage, refuse and other liquid,solid or gaseous waste which the proposed use will generate. P. Whether the natural characteristics of the site.are such that the proposed use may be. introduced there without undue disturbance or disruption of important natural features, . systems or processes and without risk of pollution to groundwater-and surface waters on and off the site. AREA VARIANCE: FINDINGS OF FACT/REASONS FOR BOARD ACTION: The Zoning Board of Appeals held a public hearing on this application on August 6,2020 at which time written and oral evidence were presented. Based upon all testimony, documentation,personal inspection of the property and surrounding neighborhood,and other evidence,the Zoning Board fmds the following facts to be true and relevant and makes the following findings: 1. Town Law§267-b(3)(b)(1). Grant of the variance will not produce an undesirable change in the character of the neighborhood or a detriment to nearby properties. The area where the proposed cabins are to be located is already cleared for tent camping sites with parking. Due to the size of the property, . And it being adjacent to Moore's Woods,there will be no detrimental effect to the surrounding neighborhood. 2. Town Law 5267-b(3)(b)(21. The benefit sought by the applicant cannot be achieved by some method, feasible for the applicant to pursue.,other than an.area variance. The proposed cabins are.504 sq.ft. with a 90 sq.ft.covered porch,(total 594 sq.ft.)which is more than the allowable 450 sq.feet.The applicant's agent stated that the applicants.determined that they could not adequality fit the modern day needs of potential campers within the size limits currently permitted by code. 3. Town Law 4267-b(3)(b)(3). The variance granted herein is mathematically substantial, representing 12%relief from the code.However,this variance is mitigated by the fact that the sites.are already cleared for tent camping with prior approvals,the overall square footage for all of the cabins will only be 10,080 square feet of lot coverage over a 23.61-acre property, and that site plan approval by the Planning Board will be required. 4. Town Law 5267-b(3)(b)(4). No evidence has been submitted to suggest that a variance in this residential community will have an adverse impact on the physical or environmental conditions in the neighborhood. The applicant must comply with Chapter 236 of the Town's Storm Water Management Code and conditions set by this board. 5, Town Law V67-b(3)(b)(5). The difficulty has been self-created. The applicant purchased the parcel after.the Zoning Code was in effect and it is presumed that the applicant had actual or constructive knowledge of the limitations on the use of the parcel under the Zoning Code in effect prior to or at the time of purchase. 6. Town Law 4267-b. Grant of the requested relief is the minimum action necessary and adequate to enable the 1p icant to enioy the benefit of 20 seasonaI rental cabins while preserving and protecting the character of the neighborhood and the health,safety and welfare of the community. Page 5;August 20,2020 #7384SE,ENF Resorts,Inc. SCTM No. 1000-40-3-5 RESOLUTION OF THE BOARD: In considering all of the above factors and applying the balancing test under New York Town Law 267-B,motion was offered by Member Lehnert,seconded by Member Weisman(Chairperson),and duly carried,to GRANT,a Special Exception, as applied for,and GRANT.the variance as applied for,as shown on the Site Plan and Architectural Plans prepared by John J. Condon,LPE,last revised.February 17,2020, SUBJECT TO THE FOLLOWING CONDITION: 1. The applicant must obtain site plan approval from the Planning Board.Failure to do so will render this Special Exception Permit and variance relief null and void. NOTE: Violations of Conditions. A violation of any limitation or condition of a special exception.approval or of any provision of this chapter applicable to a special exception. use shall constitute a violation of this chapter. The Zoning Board ofAppeals shall retain jurisdiction.and shall have the right, after a public hearing to modify, suspend or revoke .such approval or any term or condition thereof or to impose thereon one or more new conditions,pursuant to Article AXV, Section 280-141.of the Town Code. Any deviation from the variance(s) granted herein as shown on the architectural drawings, site plan and/or survey.cited above, such as,alterations. extensions, or demolitions,_.are'not authorized under this.: application when involving nonconformrties under the.zoning code. This.action does not authorize'or.. condone.any current or future use, setback or other feature of the:subject property that.may v Idte.the Zoning Code, other than such uses, setbacks and other features as are expressly addressed to"this action. In the event that this is an approval subject to conditions,,the approval shall not be.deemed effective until such time that the foregoing conditions are met,and failure to comply.therewith'w lFrender this approval null and void The Board reserves the right to substitute a similar design that is de minimis in nature for an alteration: that does not increase the degree of nonconformity. Pursuant to Chapter 280-146(B).of the Code of the Town of Southold-any variance granted by the Board of Appeals shall become null and void where a Certificate.of Occupancy has not been procured,and/or a subdivision map has not been fled with the Suffolk County Clerk,within three (3)years from the date such variance was granted. The-Board of Appeals may,upon written request prior to the date of expiration,grant an extension not to exceed three(3)consecutive one(1) year terms. ,Vote of the Board: Ayes:Members Weisman(Chairperson)Acampora,Dantes,Lehnert,and Planamento (5-0). L Leslie Kanes Weisma Chai erson Approved for filing j/a/Y/2020 �I F Sri OFFICE LOCATION: MAILING ADDRESS f Town Hall Annex ft V;S P.O.Box 1179 !' 54375 State Route 25 Q,a Southold, NY 31971. lcor.Main Rd. &Youngs Ave.) �Southold,NY Te hone:631 765-1938 , ., � g >- � le s V `t www. out-holdtownny-gov PLANNING BOARD OFFICE TON VN,OF:SOUTHOLD•. October 6, 2020 Ms. Eileen Wingate 2805 West Mill Road Mattituck, NY 11952' . Re: Site Plan Approval: Eastern Long Island Kampground Cabins 64500 CR 48, Greenport .. SCTM#1000-40.-3-5 Dear Ms. Wingate: The following resolutions were adopted at:a meeting of the Southold Town Planning Board on October 5, 2020: 1 WHEREAS, this amended site plan is to replace 33 existing tent sites with the proposed construction of 20 seasonal cabins at 504 sq., ft. each and,a 600 sq.ft. pavilion as part of an existing campground on 23.32 acres in the RR Zoning District,Green.port; and i ! WHEREAS, on December-20, 2019 and January.9, 2020, Eileen Wingate, authorized agent, submitted an Amended,Site�Plan Application-for review;.and ! WHEREAS, on February 5, 2020 and February 7, 2020, Eileen Wingate, authorized agent, submitted an.Amended Site Plan Application fee and other information for review: and WHEREAS, on February 10, 2020, the Southold Town.Planning Board determined the application as complete for review;,and,' WHEREAS, on February 10, 2020, the Planning Board, pursuant to State Environmental Quality Review ACt (SEQRA) 6 NYCRR, .Part 617, determined that the proposed action is an Unlisted Action as it does not meet-any of the thresholds of a Type ! Action., nor does it meet any of the criteria on the.Type .11 list of actions; and WHEREAS, on February 12, 2020, the Planning Board, pursuant to Southold Town .Code §280-131 C., distributed the application to the required agencies for their comments; and �(.( MrV-) �h I www.con onengmeen c V a-1 -- s�- 14. tab. �'74, r ra j, NEW YORK STATE DEPARTMENT OF ENVIRONMENTAL CONSERVATION IIY+tan T}! I[11�#fti' t'i�fN4iiEJltl`. 0ar,.f 513,94Y.'��Yk,So�Cle•�3cad;S�asY•�rt►�,�1i'Ry90 www.dec,rry.gov Qbcember• 1.2,.010 Eastern.Long.Island Kampground. -•�ez�n: Greenpott, NY1`1944 RE: Delineation of a portion of the wetlands adjacent to your property,•Eastern Long . 4Wand Karr rounds(SCTMt#1000-40-3-5) Dear Mr. Magnuson, The Qepartrnent p#IrnVironmenta! Conservation implements-Article:24, which is the Fresh Wa#fir Wetland Act. Under.Article 2. the Department has tur sd�ction over all retat�ed freshwater wetlands and 100 feet.landward of those wetlands .Manyct�vrties Wift ► rin t ` Oki 04, - Conductmg these at�tlares without fhe inefit et a f r th►s[ artment es a Violation of Af iele 24 of the Envirori errtat conservation Law (Ec and�NY"CRR.Part f; (the.re .ulatton promulgated under Article 244) Act vifites greeter than 1'.00 foot. from NY;State regutatad freshwater wetlands would not require an Article 74 ��;psrtn #frorn#his Departrn,ant.: for the purposes of delineation the wetland-boundary for a proposed project in the southeast Wer ofathe property.The management of the facility is proposing.to construct a number of cabins within the wooded-portion.of the lot, around an existing cleared trail, all in the southeast corner of the property. Staff investigated the wetlands to the east;south.and:west afi the..proposed protect No other wetland on ox edWOO 7 1 , art r1 Y corner. To the.east of the pro}ect, staTfound the regulated freshwater-wetlands.to be�greater than 200 feet from the property line.As such, staff did•not bottler to place any flags to demarcate the boundary. rxaa,urs: �itV#t�titat C�nsaru�}�n Trtr: l� sow, s;"te f lewd sae lbz;�a y n A k d stances h tte:" a+T: t 9io Yr e. th location than to the east of the project and staff placed seven flags along the wetland boundary. To the west and southwest of the project, the wetland moves away from the project;.but there is a small et:of wetland. Staff placed 2, 6gs at th&points where that smell-." . P� .. vvoflan fey tb rem a :: s:► tre t .1 ;f ate property: The existing, legally cleared.campground is located to the north of the proposed project and there are no regulated freshwater wetlands within 100 feet of the project.in that . {ocatiort: ate: fia v A aln., actfvi ies gXeat®r#han 100 feet from regulated:wetlands sto not regt�tre Art�cl+a 24 permits from this D®partfnent. The wetlands coma closest to the:project.!n the southwestern pr it'on of the project and.may come close to 100 feet from the rd lfne You 3t ould.ham !of ti a wetland'. sur�eY d and:per on a"site P Pam: ,lan for the pro eot to cen#irm the distances'estirn ted to the Reid, �01 thefnall is 13 Arid there#oreany regulated aotiity WoU rbe,eVen fafther from the wetland i3n any site plan for the project you should show a.L�rnit of Cteanng,:Grading and Ground - Dlsturbance line That is a vvork line,.in that no work of an ktr d would take place v b yo[td ti�at 1# t k*is'100 fee"or grewiter f rom aCl a#:t{ a met #lags Yau..would: tap# reed an Article:24 permits fi om this DepartMent. ` Sincere Dan Lewis a Jif IE DEC IC ILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD Town Hall Annex- 54375 Main Road - PO Box 1179, Southold, New York 11971-0959 ail¢, Telephone (631) 765-1802 - FAX (631) 765-9502 iamesh(c southoldtownny aov — sea ndCaD-southoidtownny.Nov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 11-Dec 2023 Company Name: Woodhollow Contracting, Corp Electrician's Name: Nicholas Gasparo License No.: ME-60139 Elec. email: cshcherbelis@woodhollowdesigns.com Elec. Phone No: 516-827-5916 [K I request an email copy of Certificate of Compliance Elec. Address.: 103 School St Lindenshurst NY 11757 JOB SITE INFORMATION (All Information Required) V1 Name: HNF Resorts LI / Eastern Long Island Kampground. Address: 64500 County Rd 48 Greenport, NY 11944 Cross Street: Phone No. Bldg.Permit#: LP I email: sean@magnuson.one Tax Map District: 1000 Section: Block: Z:> Lot: S BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): " 800 AMP Meter Pump 2-400 Amp Switches 4 Main Breaker Panels 20 Sub panels Square Footage: Circle All That Apply: Is job ready for inspection?: ❑ YES ❑x NO ❑Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES❑ NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood 'Reconnect Elservice Reconnect❑Underground❑Overhead # Underground Laterals M 1 F-12FI H Frame Pole Work done on Service? M Y N Additional Information: PAYMENT DUE WITH APPLICATION 4 GPL4 Faid :also Recftn tl l PERMIT 9 Address Svvltches Outlets GFI's Surface Sconces H H's UC Lts Fans Fridge HW Exhaust Oven WAD smokes DW Mini arbon Micro Generator -ombo Cooktop Transfer aC A Hood Service Amps Have Usec pedal: .omments .PERMIM '� Ad.drft&' HNF Resorts LI LLQ Eastern Long Island Kampground .-.Swilkhos 64500 CR 48/690 Queen St Greenport,,NY 11944 .,Outlets Tax Map ID: 1000-40-03-05 .;GFC`s ,SOWe zStorvcts -Ws UC.Lts 0 Fridge HW P&4*1 1-"!,POOL 0 Panel 'P 'U.0 ;.,Ekhadst f :':Oven 0 sump 0 ,,"Heater .-:Smokes .01W 0 �Ge "Aeratdr 0 Salt Gen. Carbon a, v "d MliPro �G "bDis 0 1 'Ll ft ts Heat Id1.vif1br— Pucks o ERV 0 fiLSP�A -InstAot 0 OeHurn 0 Transfer 0 DisC ' .-Combo 0 Cooktop 0 Alinispht j- '9 Olower AC 0 .-AH V 'Hood Blower r d ,:Amps K'Aave Used ' Db Su -Have b :,.Amps Used n AUG 2­2 -2025 ----------- Y < YNil t Doves lu 1' C ' SAFE-T-COVER PROPOSED 2"O ATER MAIN ,.o PROPOSED 4"13 WATER MAINTOOD l• - :(.,:' ::x.+:. .F �. �ro m I I .-k- #1 V C7 (Vin � . . _ • - o - 120 xra ( to \ ECK ::.:1= 1.: DECK `S > N UJ -- ————— iwv �; D I 1 DECK iLI12.5 .:°:,.`1' #2Ckkl ` Izs i rai DECK 1 #16 DECK MP. . _ ;..1.; --- — DECK x \ ro PAVILLION — DECK j x*.+ ---- p1p_ / yE1x DC A \.. fir.: 1T'_ / Ij _ .. 7 % / L —\'�• -\« sty - _ pFcx1t8/ �j5- r'• / \_ x I gas ate\ [j Qi+ �� :\.•. s �\ ) _ -_. `o DECK VILLAGE OF �9y /ro"r // /fin--a � �w-•• •.;•\�.. - - / \\\ \\ I .� v� .�.. \ :>i :_ : GREENPORT' :�, ;:. \ ,. VACANT LAND 102 - C' #15 / k• _' '-``~'-. .I. /max\ •`\�•,, \'.:.,-�._::= >�•i;- r0 /c \\ a \.:?:• ro n w ` J / \\ \.. \\ i,.uid"��°°hs"srm-m• P axea e - / #9 t�wmw.e m .en remm'""bra ey 'ap \ x� x2j / ROPOSFDq g \ \ J WAT MAIN ?� o o Scale:,1-=20-0- Condon Engineering, P.C. Eastern Long Islan Drawn by:JJC � 17uck,NewYork1Road Camp Grounds SP-I • �z / Mattituck,New York 11952 O� p Date:3-13-2021 (631)298-1986 690 Queen Street QO O Greenport,New York 13. RESORT RESIDENTIAL(RR)ZONE 14. THE SITE IS SERVICED BY THE GREENPORT SEWER DISTRICT,GREENPORT ELECTRIC AND SUFFOLK COUNTY WATER AUTHORITY. Waiter Line(s) UST Be inspected By The Suflblk County Dept. Of Heaifth Services; Call 852-5754, 4.8 Hours In.Advance To Schedule inspec tion(s). ENGINEER'S CERTIFICATlOA1 f2l:�UJRCD.. $UE;l41IT P.E.QR R.A. CERTIFICATION F"OR INSTALLATION ANIa CONSTRUCTION OF , FOR FINAL APPROVAL. a Z03 ao i3: `a m o-s a . x . .. APP 0.2 2021 M `8CD A � ` �. . 4/2/2021 SCDHS COMMENTS CL A .S , 'd -�'..a 3/1512021:CaBIN REV lSI0NS 10/21/2020 SCDHS COM{VIENTS:_ c F o a� . 9/ 8/2020TOWN.COMMENTS. 7/22/202U°IL REV BLDGS c Z v `� 612-2020: CDMS'COMMENTS. p �' � a N A 6/8/2020SCDHS.EOMMENTS r�, p 'A>. '� aai chi v: �' I '� 5. a �2 g b M M - /26/2020;SCbIiS;GQMMEN7S_ 0 a k a 'e �t' a°. REVISION$. co F NEW, y c� �pSEP C .O HEALTH DEPARTMENT APPROVAL STAMP r n 0 19 2 S.C.T.M.: DIST. 1.000 SEC.40 BLK. 03-LOT:05 A��FESSION��'� i i Edon Engineering, P.C. EASTERN LONG ISLAND 1755 Sigsbee Road KAMPGROUND690 QUEEN STREET Mattituck, New York 11952 GREENPORT, NY 11944 OF (631)298-1986 (631)298-2651 fax www.condonengineedng.com OVERALL SANITARY PLAN 1 Q� P Q / �rs SUBJECT PREMISES KEY MAP SCALE 1'=600' n SHEET 1 OF 2 SUFFOLK COUNTY DEPARTMENT OF HEALTH SERVICES APPROVAL OF CONSTRUCTED WORKS DATE 7/23/25 HS, Ref. Noy C-20-0055 The sevrage disposal and grater supply facilities at this location have been inspected and/or oertified by this department or other agenc es and-found to be satisfactory 30 rTH�AN PAP. P E.,CHIEF ~ OFFICE OF WASTEWATER MANAGEMENT COMcheck Software Version 4.1.5.1 } Envelope Compliance Certifict Project Information n r„ Energy'Code: 90.1 (2016),Standard Project Title: Eastern Long Island Carripground-2 Bedroom Cabin - Location:' Gr'eenportr 66. New.York Climate Zone:`.. ;:' :4'0 =* Project Type: .New Cohstruction Vertical.Glazing/Wall Area: 10%:;.•...,: Performance Sim:Specs:. EhergyPh s WI.L UQ9(EPW USA_CT CT, -Sikorsky.Mem:AP.72504.0 TMY3.epw) Construction.Site: Owner/Agent:,- _ Designer/Contractor. Eastern LQn Islarid Cam 'ground .-. ohn•.Condon, P E..�9Q`.Queen Street - Greenort,NY , .,.,:..:...,,.•...: P, 1. 1 p Condon Engineering, PC 1755 Sigsbee Road Mattituck,NY 11952 631-298-1986' Building Area Hoot Area 1-Motel.: Residential - 499 Envelope Assemblies Assembly Gross Area Cavity Iront. Proposed Budget U- 'or WValue R-Value U-Factor Factorve) Perimeter Roof 1:Attic Roof with Wood Joists;[Bldg Use 1-Motel] 499 43:0 0.0 0.621 0:021 Floor 1:Wood-Framed,[Bldg._Use 1 Motel] 499 30.0 0.0 0.033 0.033 NORTH Exterior Wall 3:Wood-Framed,16":o:c:.[Bldg..Use 1 -Motel] .144 •21.0 0.0 0.062 0.064- Window.6-.Wood Frame:Operable;Perf.Specs.:Product ID CXW14, 10 — — 0.260 0.310 SHGC 0.34,VT 0.57,[Bldg.Use 1_Motel](b) Window 7:Wood Frame:Operable,Perf.Specs.:Product ID CXW14, 10 ' — — 0:260 0.310 SHGC 0.34,VT 0.57,[Bldg.Use 1-Motel](b) . EAST Exterior Wall 2:Wood-Framed,16"o.c.,[Bldg.Use 1-Motel] 224 21.0 0.0 0.062 0.064 Window.3:Wood Frame:Operable,Pert.Specs.:Product ID CW13, 5 — 0.260 0.31.0 SHGE 0.34,-VT 0:57-i jBldg-Use-1---Wotel}(b} Window 4:Wood Frame:Operable,Perf.Specs.:Product ID CX14, 10 — — 0.260 0.310 SHGC 0.34,vT 0.57,[Bldg.Use 1-Motel](b) .Window 5:Wood Frame:Operable;'Perf.Specs.:.ProductID CX14, 10 — — 0.260 0.310 SHGC 0.34,VT 0.57,[Bldg.Use 1 Motel](b) SOUTH . Exterior Wall 1:'Wood-Framed, 16"o.c.,[Bldg.Use 1=Motel] -144 21.0 0.0 . 0.062 6.064 Window 1:Wood Frame:Operable,Perf.Specs.:Product ID CXW14, 10 — = 0.260. 0.310 SHGC 0.34,VT 0.57,[Bldg.Use 1-Motel](b) .Window 1 copy 2:Wood Frame:Operable,Perf.Specs.:Product ID 10 — 0.260 0.310 CXW14,SHGC 0.34,VT 0.57,[Bldg.Use 1 -Motel](b) Door 1:Wood,Swinging,[Bldg.Use 1-Motel] 2 — — 0.300 0.370 Project Title: Eastern.Long.lsland Campground-2 Bedroom:Cabin Report date: 03/05/21 Data filename: C:\Users\Owner\Favorites\ComChecks\2,Bedroom Cottage.cck Page 1 of 10 Assembly. Gross Area Cavity Cont. Proposed Budget U- or R-Value R-Value. U-Factor Factor(.) j/ Perimeter /;%WEST Exterior Wall 4:Wood-Framed, 16"o.c.,[Bldg.Use 1 -Motel] 224 21.0 0.0 0.062 0.064 i Window 7:Wood.Frame:Operable,Perf.Specs.:Product ID CW13, 5 — — 0.260 0,310 SHGC 0.34,VT 0.'57,[Bldg.Use 1-Motel](b) (a):Budget U-factors are used for software baseline calculations ONLY,and are not code requirements. (b)Fenestration product performance mustbe.certified in accordance•with.NFRC and requires supporting.documentation. Envelope PASSES: Design %better than code Envelope Compliance Statement r Compliance Statement: The proposed envelope design,represented.in this document is.consistent with the.building plans, specif Ica tions,acid other calculations sUbm�tted with this permit application:The proposed envelope systems have been designed to.meet the 90.1 (2016)Standard req ements in COMcheck Version 4.1.5.1 and to comply with any applicable mandatory requirements listed in the Inspection klist. Name.Title'' Date Project Title: Eastern Long Island Campground-2.Bedroom Cabin Report date: 03/05/21 Data filename: C:\Users\Owner\Fa•vorites\ComChecks\2 Bedroom Cottage.cck Page 2 of 10 h 4 CABIN #9 Fire Sprinkler Reports for Eastern,Long island Campground ' 690 Queen Street Greenport;'New York PEE 0 F Nei �\o�N ccd yob � G F cz APPROVED AS NOTED DATE;2(ZWB.P.4t FEE BY: NOTIFY FIRE MARSHAL AT 631-765-1802 Prepared By: FOR THE FOLLOWING INSPECTIONS: John Condon 1. ROUGH INSPECTION Condon Engineering,P.C. 2. COMPLIANCE TESTING 1755 Sigsbee Road 3. FINAL INSPECTION Mattituck,New York 986 ALL WORK SHALL COMPLY WITH NYS January 631-298-1 8-1 86 CODES AND APPLICABLE NFPA 024 STANDARDS Fire-Fire Sprinkler Hydraulics Calculation Program Elite Software Development,Inc. Condon EngineeringAk Cabin#9 Mattituck, NY 11952 'age 2 General Project Data Report General Data Project Title: Cabin#9 Project File Name: Cabin 9..fiw Designed By: John Condon Date: January 31, 2024 Code Reference: NFPA 13 R Approving Agency: LOCAL JURISDICTION Client Name: Eastern Long Island Campground Phone: Address: 690 Queen Street City, State Zip Code: Greenport, New York Company Name: Condon Engineering, P.C. Representative: John Condon Company Address: 1755 Sigsbee Road City And State: Mattituck, New York Phone: 631-298-1986 Building Name: Cabin#9 Building Owner: Contact at Building: Phone at Building: Address Of Building: 690 Queen Street City, State Zip Code: Greenport, New York Project Data Description Of Hazard: Light Hazard Sprinkler System Type: Wet Design Area Of Water Application: 144 ft2 Maximum Area Per Sprinkler: 144 ft2 Default Sprinkler K-Factor: 5.60 K Default Pipe Material: SCHED 40 STEEL BLK Inside Hose Stream Allowance: 0.00 gpm Outside Hose Stream Allowance: 0.00 gpm In Rack Sprinkler Allowance: 0.00 gpm Sprinkler Specifications Make: Reliable Model: G5-56 Size: 1/2 Temperature Rating: 135 F NONE Water Supply Test Data Source Of Information: SCWA Test Hydrant ID: 825134000 Date Of Test: 1-11-2021 Hydrant Elevation: 0 ft Static Pressure: 66.00 psi Test Flow Rate: 1503.00 gpm Test Residual Pressure: 52.00 psi Calculated System Flow Rate: 91.70 gpm Calculated Inflow Residual Pressure: 52.96 psi Available Residual Pressure At 65.92 psi System Flow: Calculation Project Data Calculation Mode: Demand HMD Minimum Residual Pressure: 7.00 psi Minimum Desired Flow Density: 0.09 gpm/ft2 Maximum Water Velocity: 20.00 ft/s Maximum Frictional Loss/ 100 feet: 20.00 psi Number Of Active Nodes: 26 Number Of Active Pipes: 25 Number Of Inactive Pipes: 0 Number Of Active Sprinklers: 6 Number Of Inactive Sprinklers: 0 C:\...\Cabin 9.fiw Wednesday, January 31, 2024, 11:02 AM Fire-Fire Sprinkler Hydraulics Calculation Program Elite Software Development,Inc. Condon Engineering Fri Cabin#9 Mattituck,NY-11952 r sue, • Page 3 Fire Sprinkler input Data Node Input :Data - srr,'r'X Area Group Sprinkler Pressure Node Elev(ft) Non-Sprinkler Node Node Description Branch Dia. KFactor(K) Estimate (psi) Branch Non- Flow(gpm) No. Branch Description (in) Branch Len. Branch Stnd Stnd Fittings Branch Sprk (ft) Fittings (ft) KFactor(K) 1 Sprinkler A 5.60 7.80 11.00 0.00 --- 0.000 0.0 --- 0.0 0.00 2 Sprinkler A 5.60 7.72 11.00 0.00 --- 0.000 0.0 ---- 0.0 0.00 3 Sprinkler A 5.60 7.70 11.00 0.00 -- 0.000 0.0 --- 0.0 0.00 4 Sprinkler A 5.60 7.46 11.00 0.00 ---- 0.000 0.0 ---- 0.0 0.00 5 Sprinkler A 5.60 7.03 11.00 0.00 --- 0.000 0.0 ---- 0.0 0.00 6 Sprinkler A 5.60 7.00 11.00 0.00 ---- 0.000 0.0 --- 0.0 0.00 7 No Discharge ---- N/A 8.11 11.00 0.00 --- 0.000 0.0 ---- 0.0 0.00 8 No Discharge ---- N/A 8.13 11.00 0.00 --- 0.000 0.0 ---- 0.0 0.00 9 No Discharge ---- N/A 8.19 11.00 0.00 -- 0.000 0.0 --- 0.0 0.00 10 No Discharge -- N/A 8.66 11.00 0.00 ---- 0.000 0.0 ---- 0.0 0.00 11 No Discharge --- N/A 8.50 11.00 0.00 ---- 0.000 0.0 ---- 0.0 0.00 12 No Discharge ---- N/A 9.14 11.00 0.00 0.000 0.0 --- 0.0- 0.00 13 No Discharge ---- N/A 16.68 -3.00 0.00 ---- 0.000 0.0 --- 0.0 0.00 15 No Discharge ---- N/A 23.91 -3.00 0.00 ---- 0.000 0.0 ---- 0.0 0.00 16 No Discharge --- N/A 22.35 3.00 0.00 ---- 0.000 0.0 --- 0.0 0.00 17 No Discharge ---- N/A 28.37 3.00 0.00 --- 0.000 0.0 ---- 0.0 0.00 C:\...\Cabin 9.fiw Wednesday, January 31, 2024, 11:02 AM Fire--Fire Hydraulics Calculation Program Elite Software Development,Inc. Condon Engineeniig SCabin#9 Mattituck, Y"N 11952sfa► - -- - Pa e 4 Fire $prinkler.lnput Data Pl,ocle Input Data (�cont d�) 110k Area Group Sprinkler Pressure Node Elev(ft) Non-Sprinkler Node Node Description Branch Dia. KFactor(K) Estimate (psi) Branch Non- Flow(gpm) No. Branch Description (in) Branch Len. Branch Stnd Stnd Fittings Branch Sprk (ft) Fittings (ft) KFactor(K) 18 No Discharge ---- N/A 32.52 -4.00 0.00 --- 0.000 0.0 --- 0.0 0.00 20 No Discharge --- N/A 33.29 -4.00 0.00 ---- 0.000 0.0 ---- 0.0 0.00 30 No Discharge ---- N/A 33.80 4.00 0.00 ---- 0.000 0.0 ---- 0.0 0.00 31 No Discharge ---- N/A 35.08 4.00 0.00 ---- 0.000 0.0 ---- 0.0 0.00 32 No Discharge --- N/A 35.50 -4.00 0.00 ---- 0.000 0.0 ---- 0.0 0.00 33 No Discharge ---- N/A 39.59 -4.00 0.00 ---- 0.000 0.0 ---- 0.0 0.00 35 No Discharge ---- N/A 40.89 -4.00 0.00 ---- 0.000 0.0 ---- 0.0 0.00 36 No Discharge --- N/A 43.90 -4.00 0.00 0.000 0.0 -- 0.0 0.00 37 No Discharge ---- N/A 52.64 -4.00 0.00 0.000 0.0 ---- 0.0 0.00 40 No Discharge -- N/A 52.96 -4.00 0.00 ---- 0.000 0.0 ---- 0.0 0.00 C:\...\Cabin 9.fiw Wednesday, January 31, 2024, 11:02 AM �Fire-Fire Sprinkler Hydraulics Calculation Program' Elite_Software Development,Inc. Condon Engineering Jf t �•� Cabin#9 'Maftftubk,':NY"11952 _ - ;,�;� 'Page 5 Fire Sprinkler Input Data Pipe Input ®ataWON M- r Nominal Nominal Fitting Total CFactor Beg. End. Pipe Description Diameter Type Fitting Length Length Length (gpm/inch- Node Node (inch) Group Data (feet) (feet) (feet) psi) 1 11 SCHED 40 STEEL BLK 1.000 0 T 5.00 3.50 8.50 120 2 11 SCHED 40 STEEL BLK 1.000 0 T 6.00 3.50 9.50 120 3 9 SCHED 40 STEEL BLK 1.000 0 ' T 2.50 3.50 6.00 120 4 8 SCHED 40 STEEL BLK 1.000 0 T 5.00 3.50 8.50 120 5 7 SCHED 40 STEEL BLK 1.000 0 ET 9.50 4.90 14.40 120 6 7 SCHED 40 STEEL BLK 1.000 0 ET 10.00 4.90 14.90 120 7 8 SCHED 40 STEEL BLK 2.000 0 1.50 0.00 1.50 120 8 9 SCHED 40 STEEL BLK 2.000 0 3.00 0.00 3.00 120 9 10 SCHED 40 STEEL BLK 2.000 0 T 5.50 7.10 12.60 120 11 10 SCHED 40 STEEL BLK 2.000 0 T 7.50 7.10 14.60 120 10 12 SCHED 40 STEEL BLK 2.000 0 E 2.50 3.50 6.00 120 12 13 SCHED 40 STEEL BLK 2.000 0 E 15.00 3.50 18.50 120 13 15 SCHED 40 STEEL BLK 2.500 0 2ET 197.50 16.90 214.40 120 15 16 SCHED 40 STEEL BLK 2.000 0 2E 6.00 7.00 13.00 120 16 17 Backflo Prev 6.000 Loss 17 18 SCHED 40 STEEL BLK 2.000 0 2E 7.00 7.00 14.00 120 18 20 SCHED 40 STEEL BLK 2.500 0 T 2.50 8.50 11.00 120 20 30 SCHED 40 STEEL BLK 4.000 0 165.00 0.00 165.00 120 30 31 SCHED 40 STEEL BLK 4.000 0 EL 400.00 11.30 411.30 120 31 32 SCHED 40 STEEL BLK 4.000 0 T 120.00 14.20 134.20 120 32 33 SCHED 40 STEEL BLK 3.000 0 21-T 332.00. 17.70 349.70 120 33 35 SCHED 40 STEEL BLK 3.000 0 111.00 0.00 111.00 120 35 36 Backflo Prev 6.200 Loss 36 37 SCHED 40 STEEL BLK 2.000 0 2L 105.00 4.20 109.20 120 37 40 SCHED 40 STEEL BLK 6.000 0 T 712.00 21.40 733.40 120 C:\...\Cabin 9.fiw Wednesday, January 31, 2024, 11:20 AM Fire-Fire Sprinkler Hydraulics Calculation Program R, Elite Software Development,Ino. Condon Engineering E 1� Cabin I MattitucR, NY ill .. _ .. ,. r `• Page 6 Fire Sprinkler,Output Data O4erall Node Gro,,upi'ngs.0utput=D.ata Pipe Segment Pipe Pipe Sprinkler Flow Non-Sprinkler Flow Beg. Node Imbalance Beg. End. Type Flow Rate At Beg. Node Out(+) In (-) Residual Flow At Beg. Node Node Group (gpm) (gpm) (gpm) (gpm) Pressure(psi) Node(gpm) 1 11 0 t-15.64 15.64 0.00 0.00 7.80 2 11 0 -15.56 15.56 0.00 0.00 7.72 0.00011 3 9 0 -15.54 15.54 0.00 0.00 7.70 0.00012 4 8 0 -15.29 15.29 0.00 0.00 7.46 0.00010 5 7 0 -14.85 14.85 0.00 0.00 7.03 0.00007 6 7 0 -14.82 14.82 0.00 0.00 7.00 0.00008 7 5 0 14.85 0.00 0.00 0.00 8.11 -0.00007 7 6 0 14.82 7 8 0 -29.67 8 4 0 15.29 0.00 0.00 0.00 8.13 0.00000 8 7 0 29.67 8 9 0 -44.96 9 3 0 15.54 0.00 0.00 0.00 8.19 0.00000 9 8 0 44.96 9 10 0 -60.50 10 9 0 60.50 0.00 0.00 0.00 8.66 0.00000 10 11 0 3110 10 12 0 -91.70 11 1 0 15.64 0.00 0.00 0.00 8.50 0.00000 11 2 0 15.56 11 10 0 -31.20 12 10 0 91.70 0.00 0.00 0.00 9.14 0.00000 12 13 0 -91.70 13 12 0 91-.70 0.00 0.00 0.00 16.68 0.00000 13 15 0 -91.70 15 13 0 91.70 0.00 0.00 0.00 23.91 0.00000 15 16 0 -91.70 16 15 0 91.70 0.00 0.00 0.00 22.35 -0.03947 16 17 0 -91.74 17 16 0 91.74 0.00 0.00 0.00 28.37 0.03947 17 18 0 -91.70 18 17 0 91.70 0.00 0.00 0.00 32.52 0.00000 18 20 0 -91.70 C:\...\Cabin 9.fiw Wednesday, January 31, 2024, 11:02 AM Fire-Fire Sprinkler Hydraulics Calculation Program Elite Software Development,Inc. Condon Engineering ' } a Cabin#9 Mattituck,NY 11952' t Page 7 Fire Sprinkler Outpuf Data O, erai ` Nocle�Gr..oupi`ngs�'Outpuf Data (cont'd) Pipe Segment Pipe Pipe Sprinkler Flow Non-Sprinkler Flow Beg. Node Imbalance Beg. End. Type Flow Rate At Beg. Node Out(+) In (-) Residual Flow At Beg. Node Node Group (gpm) (gpm) (gpm) (gpm) Pressure(psi) Node (gpm) 20 18 0 91.70 0.00 0.00 0.00 33.29 0.00000 20 30 0 -91.70 30 20' 0 91.70 0.00 0.00 0.00 33.80 0.00000 30 31 0 -91.70 31 30 0 91.70 0.00 0.00 0.00 35.08 0.00000 31 32 0 -91.70 32 31 0 91.70 0.00 0.00 0.00 35.50 0.00000 32 33 0 -91.70 33 32 0 91.70 0.00 0.00 0.00 39.59 0.00000 33 35 0 -91.70 35 33 0 91.70 0.00 0.00 0.00 40.89 -0.03947 35 36 0 -91.74 36 35 0 91.74 0.00 0.00 0.00 43.90 0.03947 36 37 0 -91.70 37 36 0 91.70 0.00 0.00 0.00 52.64 0,00000 37 40 0 -91.70 40 37 0 91.70 0.00 0.00 -91.70 52.96 C:\...\Cabin 9.fiw Wednesday, January 31, 2024, 11:02 AM • Fire=Fire Sprinkler Hydraulics Calculation Program Elite Software Development,Inc. Condon Engineering 4x Cabin#9 Mattituck,NY 11952 TAW, : Page 8 Fire Sprinkler Output Data Overall Pipe Output-,Data /ft Pipe-Len. . Beg. Nodal Spk/Hose Residual Nom. Dia. q (gpm) F. PF-(psi) Elevation Q (gpm) (psi/ft) Fit-Len. End. KFactor Discharge Pressure Inside Dia. PE-(psi) Node (K) (feet) (gpm) (psi) C-Value Velocity Fittings Tot-Len. PT-(psi) (fps) Type-Grp (ft) 5 5.60 11.00 14.85 7.03 1.00 14.85 0.07505 9.50 1.081 7 0.00 11.00 0.00 8.11 1.049 14.85 ET 4.90 0.000 SCHED 40 STEEL BLK 120 5.51 0 14.40 1.081 6 5.60 11.00 14.82 7.00 1.00 14.82 0.07473 , 10.00 1.113 7 0.00 11.00 0.00 8.11 1.049 14.82 ET 4.90 0.000 SCHED 40 STEEL BLK 120 5.50 0 14.90 1.113 4 5.60 11.00 15.29 7.46 1.00 15.29 0.07921 5.00 0.673 8 0.00 11.00 0.00 8.13 1.049 15.29 T 3.50 0.000 SCHED 40 STEEL BLK 120 5.68 0 8.50 0.673 7 0.00 11.00 0.00 8.11 2.00 0.00 0.00993 1.50 0.015 8 0.00 11.00 0.00 8.13 2.067 29.67 ----- 0.00 0.000 SCHED 40 STEEL BLK 120 2.84 0 1.50 0.015 3 5.60 11.00 15.54 7.70 1.00 16.54 0.08165 2.50 0.490 9 0.00 11.00 0.00 8.19 1.049 15.54 T 3.50 0.000 SCHED 40 STEEL BLK 120 5.77 0 6.00 0.490 8 0.00 11.00 0.00 8.13 2.00 0.00 0.02142 3.00 0.064 9 0.00 11.00 0.00 8.19 2.067 44.96 ----- 0.00 0.000 SCHED 40 STEEL BLK 120 4.30 0 3.00 0.064 9 0.00 11.00 0.00 8.19 2.00 0.00 0.03710 5.50 0.468 10 0.00 11.00 0.00 8.66 2.067 60.50 T 7.10 0.000 SCHED 40 STEEL BLK 120 5.78 0 12.60 0.468 11 0.00 11.00 0.00 8.50 2.00 0.00 0.01090 7.50 0.159 10 0,00 11.00 0.00 8.66 2.067 31.20 T 7.10 0.000 SCHED 40 STEEL BLK 120 2.98 0 14.60 0.159 1 5.60 11.00 15.64 7.80 1.00 15.64 0.08259 5.00 0.702 11 0.00 11.00 0.00 8.50 1.049 15.64 T 3.50 0.000 SCHED 40 STEEL BLK 120 5.81 0 8.50 0.702 2 5.60 11.00 15.56 7.72 1.00 15.56 0.08185 6.00 0.778 11 0.00 11.00 0.00 8.50 1.049 15.56 T 3.50 0.000 SCHED 40 STEEL BLK 120 5.78 0 9.50 0.778 10 0.00 11.00 0.00 8.66 2.00 0.00 0.08010 2.50 0.481 12 0.00 11.00 0.00 9.14 2.067 91.70 E 3.50 0.000 SCHED 40 STEEL BLK 120 8.77 0 6.00 0.481 12 0.00 11.00 0.00 9.14 2.00 0.00 0.08010 15.00 1.482 13 0.00 -3.00 0.00 16.68 2.067 91.70 E 3.50 6.062 SCHED 40 STEEL BLK 120 8.77 0 18.50 7.544 C:\...\Cabin 9.fiw Wednesday, January 31, 2024, 11:02 AM Fire-Fire Sprinkler Hydraulics Calculation Program Elite Software Development,Inca 1 Condon Engineering Cabin#9 r2 �'x Mattituck,NY 11952 E,y1�u.'+ Page 9' Fire Sprinkler Output Data Overall'Pipe Ouf but Data (cont'!). /ft Pipe-Len L. . Beg. Nodal Spk/Hose Residual Nom. Dia. q (gpm) F. PF-(psi) Elevation Q (gpm) (psi/ft) Fit-Len. End. KFactor Discharge Pressure Inside Dia, PE-(psi) Node (K) (feet) (gpm) (psi) C-Value Velocity Fittings Tot-Len. PT-(psi) (fps) Type-Grp (ft) 13 0.00 -3.00 0.00 16.68 2.50 0.00 0.03371 197.50 7.227 15 0.00 -3.00 0.00 23.91 2.469 91.70 2ET 16.90 0.000 SCHED 40 STEEL BLK 120 6.15 0 214.40 7.227 15 0.00 -3.00 0.00 23.91 2.00 0.00 0.08010 6.00 1.041 16 0.00 3.00 0.00 22.35 2.067 91.70 2E 7.00 -2.598 SCHED 40 STEEL BLK 120 8.77 0 13.00 -1.557 16 Backflo 3.00 22.35 91.74 Prev 17 6.00 psi 3.00 28.37 17 0.00 3.00 0.00 28,37 2.00 0.00 0.08010 7.00 1.121 18 0.00 -4.00 0.00 32.52 2.067 91.70 2E 7.00 3.031 SCHED 40 STEEL BLK 120 8.77 0 14.00 4.152 18 0.00 -4.00 0.00 32.52 2.00 . 0.00 0.08010 2.50 0.769 20 0.00 -4.00 0.00 33.29 2.067 91.70 T 7.10 0.000 SCHED 40 STEEL BLK 120 8.77 0 9.60 0.769 20 0.00 -4.00 0.00 33.29 4.00 0.00 0.00312 165.00 0.514 30 0.00 -4.00 0.00 33.80 4.026 91.70 ---- 0.00 0.000 SCHED 40 STEEL BLK 120 2.31 0 165.00 0.514 30 0.00 -4.00 0.00 33.80 4.00 0.00 0.00312 400.00 1.282 31 0.00 -4.00 0.00 35.08 4.026 91.70 EL 11.30 0.000 SCHED 40 STEEL BLK 120 2.31 0 411.30 1.282 31 0.00 -4.00 0.00 35.08 4.00 0.00 0,00312 120.00 0.418 32 0.00 -4.00 0.00 35.50 4.026 91.70 T 14.20 0.000 SCHED 40 STEEL BLK 120 2.31 0 134.20 0.418 32 0.00 -4.00 0.00 35.50 3.00 0.00 0.01170 332.00 4.093 33 0.00 -4.00 0.00 39.59 3.068 91.70 2LT 17.70 0.000 SCHED 40 STEEL BLK 120 3.98 0 349.70 4.093 33 0.00 -4.00 0.00 39.59 3.00 0.00 0.01170 111.00 1.299 35 0.00 -4.00 0.00 40.89 3.068 91.70 ----- 0.00 0.000 SCHED 40 STEEL BLK 120 3.98 0 111.00 1.299 35 Backflo -4.00 40.89 91.74 Prev 36 3.00 psi -4.00 43.90 C:\...\Cabin 9.fiw Wednesday, January 31, 2024, 11:02 AM Fire-Fire Sprinkler Hydraulics.Calculation Program Elite Software Development,Inc. Condon Engineering i `- Cabin#9 Mattituck, NY 11952 ,.W.`• Page 10 Fire Sprinkler Output Data Overall Pipe'Ou#put Data (donVd) Beg. Nodal Spk/Hose Residual Nom. Dia. q (gpm) F. L./ft Pipe-Len. PF-(psi) Elevation Q(gpm) (psi/ft) Fit-Len. End. KFactor Discharge Pressure Inside Dia. PE-(psi) Node (K) (feet) (gpm) (psi) C-Value Velocity Fittings Tot-Len. PT-(psi) (fps) Type-Grp (ft) 36 0.00 -4.00 0.00 43.90 2.00 0.00 0.08010 105.00 8.746 37 0.00 4.00 0.00 52.64 2.067 91.70 2L 4.20 0.000 SCHED 40 STEEL BLK 120 8.77 0 109.20 8.746 37 0.00 4.00 0.00 52.64 6.00 0.00 0.00042 712.00 0.311 40 0.00 -4.00 0.00 52.96 6.065 91.70 T 21.40 0.000 SCHED 40 STEEL BLK 120 1.02 0 733.40 0.311 C:\...\Cabin 9.fiw Wednesday, January 31, 2024, 11:02 AM Fire-Fire Sprinkler Hydraulics Calculation Program Elite Software Development,Inc. Condon Engineering ! t � Cabin#9 Mattituck,NY 11952 � stu Page 11 Fire Sprinkler.Output. Data Overall Spr'nkle.r Output-Data; Flowing Area Group Sprinkler Sprinkler Residual Flowing Area Flowing Sprinkler Sprinkler Elevation Pressure 2 Density Discharge Node No. Code KFactor(K) (feet) (psi) (ft ) (gpm/ft2) (gpm) 1 A 5.60 11.00 7.80 144.00 0.109 15.64 2 A 5.60 11.00 7.72 144.00 0.108 15.56 3 A 5.60 11.00 7.70 144.00 0.108 15.54 4 A 5.60 11.00 7.46 144.00 0.106 15.29 5 A 5.60 11.00 7.03 144.00 0.103 14.85 6 A 5.60 11.00 7.00 144.00 0.103 14.82 Sub Totals For Group A 864.00 0.106 91.70 Totals For All Groups 864.00 0.106 91.70 C:\...\Cabin 9.fiw Wednesday, January 31, 2024, 11:02 AM Fire-Fire Sprinkler Hydraulics Calculation Program . Elite Software Development,Inc. Condon Engineering f k`t Cabin#9 Mattituck,NY 11952 FIE t' Page 12 Fire Sprinkler Output Summary Hydraulically Most Demanding Sprinkler Node HMD Sprinkler Node Number: 6 HMD Actual Residual Pressure: 7.00 psi HMD Actual Flow: 14.82 gpm Sprinkler Summary Sprinkler System Type: Wet Specified Area Of Application: 144.00 ft2 Minimum Desired Density: 0.090 gpm/ft2 Application Average Density: 0.637 gpm/ft2 Application Average Area Per Sprinkler: 24.00 ft2 Sprinkler Flow: 91.70 gpm Average Sprinkler Flow: 15.28 gpm Flow Velocity And Imbalance Summary Maximum Flow Velocity( In Pipe 10- 12) 8.77 ft/sec Maximum Velocity Pressure (In Pipe 10- 12) 0.52 psi Allowable Maximum Nodal Pressure Imbalance: 0.0100 psi Actual Maximum Nodal Pressure Imbalance: 0.0069 psi Actual Average Nodal Pressure Imbalance: 0.0022 psi Actual Maximum Nodal Flow Imbalance: 0.0395 gpm Actual Average Nodal Flow Imbalance: 0.0061 gpm Overall Network Summary Number Of Unique Pipe Sections: 25 Number Of Flowing Sprinklers: 6 Pipe System Water Volume: 1769.62 gal Sprinkler Flow: 91.70 gpm Non-Sprinkler Flow: 0.00 gpm Minimum Required Residual Pressure At System Inflow 52.96 psi Node: Demand Flow At System Inflow Node: 91.70 gpm C:\...\Cabin 9.fiw Wednesday, January 31, 2024, 11:02 AM O Fire-Fire Sprinkler Hytlraulics Calculation Program- ,� Elite Software Development,Inc. Condon Engineering � { '�� 'Cabin#9 Mattituck;NY 1"1952 -. <ram►� Page 13 Fire Sprinkler Output Data "Hydrau�lic��Snu�p,,P,ly/�D�emandGra�ph � ?,,, �. ,00 90 80 70 6 Q. 60 � 52 50 N ^L LL 40 30 20 10 0 2 4 6 8 10 12 14 16 18 20 Flowrate(x100) gpm Supply Curve Data Static Pressure: 66 psi Test Residual Pressure: 52 psi Test Flow Rate: 1503 gpm Demand Curve Data Calculated Residual Pressure: 52.96 psi Calculated Flow Rate:91.70 gpm Excess Available Residual Pressure At Calculated Flow: 12.97 psi Pressure Required For First Sprinkler Downstream From Inflow Node To Flow: 15.50 psi C:\...\Cabin 9.fiw Wednesday, January 31, 2024, 11:02 AM