Loading...
HomeMy WebLinkAbout51724-Z ho0,4�oF SOpTyo�° Town of Southold * * P.O. Box 1179 ,0 53095 Main Rd orm Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 46438 Date: 08/22/2025 THIS CERTIFIES that the building SINGLE FAMILY DWELLING-ALTERATION Location of Property: 505 Cedar Dr East Marion, NY 11939 Sec/Block/Lot: 22.-2-3 8 Conforms substantially to the Application for Building Permit heretofore,filed in this office dated: 01/29/2025 Pursuant to which Building Permit No. 51724 and dated: 03/11/2025 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: Alterations including conversion of attached garage to living space and "as built" finished basement with bath to existing single-family dwelling as applied for. The certificate is issued to: Marinos Lilikas , Anna Lilikas Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: 51724 8/7/2025 PLUMBERS CERTIFICATION: Gemini Plumbing LLC 8/22/2025 � AuVinze Signature �o��ofSOUryolo TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE eo I SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 51724 Date: 03/11/2025 Permission is hereby granted to: Marinos Lilikas 505 Cedar Dr East Marion, NY 11939 To: Legalize an "as built"finished basement and construct alterations to convert the attached garage to living space, relocate the interior basement stairs and install HVAC split system to an existing single- family as applied for. Additional certification may be required. Premises Located at: 505 Cedar Dr, East Marion, NY 11939 SCTM#22.-2-38 Pursuant to application dated 01/29/2025 and approved by the Building Inspector. To expire on 03/11/2027. Contractors: Required Inspections: Fees: As Built Alteration $1,380.00 Single Family Dwelling- Alteration $161.00 CO Single Family Dwelling-Addition/Alteration $100.00 Total $1,641.00 --Ji2 Building Inspector o��pF S0(/T�,QI � o Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 G • Q Southold,NY 11971-0959 �Q �yenU ,N BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Marinos Lilikas Address: 505 Cedar Dr City: East Marion St: NY Zip: 11939 Building Permit t 51724 Section: 22 Block: 2 Lot: 38 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: AS BUILT License No: SITE DETAILS Office Use Only Indoor r�71. Basement rv-- Service [✓ Solar F Outdoor r— 1st Floor r Pool r Spa 17- Renovation F 2nd Floor 177 Hot Tub r Generator F Survey r Attic (- Garage Battery Storage (— INVENTORY Service 1 ph r- Heat Duplec Recpt 5 Ceiling Fixtures Bath Exhaust Fan Service 3 ph F Hot Water GFCI Recpt 2 Wall Fixtures Smoke Detectors 4 Main Panel 200A A/C Condenser Single Recpt Recessed Fixtures 10 CO Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO 2 Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors 1 Disconnect Switches 4 4'LED Exit Fixtures Other Equipment: 200A Panel 40 Circuits / 24 Used Notes: � AS BUILT NO VISUAL DEFECTS " Garage Converted to Living Space & Finished Basement Inspector Signature: Date: August 7, 2025 Sean Devlin ellx Electrical Inspector sean.devlin(cD-town.southold.ny.us 505CedarBasement&Garage2 Liv Town Hall Annex �®� ® l4o 4�91pl)765-1802 54375 Main Road P. 0. Box 1179 ® Alt Southold, NY 11971-0959 W ® A , No 2 2 2025 1 �'tme "� B uElding D-P Town�9( -bOU��^tbjE9 BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATION Date: ':� 22 jo 1.5 Building Permit No. 1 �� Owner: L A .� (Please print) Plumber: e lyl���? ) eztJm I j 7 yI C (Please print) I certify that the solder used in the water supply system contains less than 2/10 of 1% lead. Oda C� (/u rU (Plumbers Signature) Sworn to before me this a �" day of 1� 20 44 Notary Public, County PENNY BEDELL Notary Public,State of blew York: No.01 BE6099317 Qualified in Suffolk County Commission Expires Sept.29, 1 laf so 7��o SOUTHOLD BUILDING DEPT. 631-765-1802 INSPECTION [ ] FOUNDATION:1 ST/ REBAR [ ] ROUGH PLBG. [ -] FOUNDATION 2ND = [ ] 'INSULATION/CAULKING [ ] FRAMING/STRAPPING [ ] FINAL [ } FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ..] FIRE RESISTANT-CONSTRUCTION [ ] FIRE-RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION- [ ] PRE C/O [ ] 'RENTAL REMARKS: DATE INSPECTOR .. ✓ , f N\OF SOUTyO� I # * TOWN-OF SOUTHOLD BUILDING DEPT. . utN 631-765-1802 INSPECTION [ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [vj FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY- [ ] FIRE SAFETY INSPECTION [ ] FIRE-RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] 'ELECTRICAL (ROUGH) [ ]. ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ]. RENTAL REMARKS_: &d"L4 7"b Q-o 14A4 n im&W_ DATE ANSPECTOR SOl/ThO�o # # TOWN OF SOUTHOLD BUILDING DEPT. o�y o MV,��o 631-765-1802 INSPECTION [ ] FOUNDATION 1 ST/REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND I INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ . ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL)- CODE VIOLATION [ ]. PRE C/O [ ] RENTAL REMARKS: Av,.c.Lq'& L /!.5u � vkf oo l'y,s-& j_k, Oy ere'.0 SATE 7 INSPECTOR SOUTyOIo /�� L) C�� # # AWN Of SOUTHOLD BUILDING cou 631-765-1802 INSPECTION [ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ]- FIREPLACE,& CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION ] PRE C/O�y [ ]. RENTAL REMARKS. S�)V) ko"T ' &�7 WIA zj bc,feo eA wt /I Pe -_ Ao k\atV b(Il LAS � qe -jTJp ` DATE INSPECTOR �51_�l a SOGIyo� # . TOWN OF SOUTHOLD BUILDING DEPT. 631-765-1802 -.INSPECTION ].- FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ �FINAL LATION/CAULKING FRAMING/STRAPPING [ [ ] FIREPLACE & CHIMNEY [ ] FIRE'SAFETY INSPECTION [ ] FIRE`RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ]- CODE VIOLATION. [ ] PRE.C/O [ ] RENTAL I�SKS. ti intAW �, v s _Otl 4 DATE ANSPECTOR OF SO�Th°� * TOWN OF SOUTHOLD BUILDING DEPT. utm� 631-765-1802 INSPECTION [ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] I LATIIAe- OW1 LKING [ ] FRAMING/STRAPPING [ FINAL '�,( [ ] FIREPLACE & CHIMNEY f ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT- CONSTRUCTION ' [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) - [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REM RKS: DATE INSPECTOR Robert I. Brown Architect, P.C. 205 Bay Avenue,Greenport, NY 11944 info@ribrownarchitect.com 631-477-9752 22 May, 2025 Town of Southold Building Department Southold,NY 11971 Re: Lilikas Residence 505 Cedar Drive East Marion,NY 11939 Building Permit No. 51724 To whom it may concern, This letter is to confirm that based on observations of the site by my staff, and to the best of my knowledge, belief, and professional judgement, the new insulation is installed in all opened and modified exterior structural elements and is as stated,- 2x4 walls; R-13 batt insulation 2x10 floor; R-30 batt insulation 2x8 ceiling; R-19 batt insulation If you have any questions, or require additional information, please feel free to contact me. Sincerel -,_ � D M AY 2 3 2025 Building Department 'town of Southold Robert Brown, A.I.A. j, i T — F_ A r l , • 13 l�i� r � 9^E 1! � fil�l� :�4�fi i� '• r 9 P110E IVA ii !! 'i i —— ----- h ------ e ` t I NE L+ ----- , sz 24442 1 l if "ry I a-- x0' �IIIt�I it ._ ---- I� rr — I i. m - n m •n 1 `s. J u r a r m N +a �y N ,a f a 0 ,d m �i 40 .n .n N ~ ...- h 4 h a ECEU VE 2025 BuiIding Department Town of Southold a 'm I 9 I ,G R • y li ny BBB, wry ^(r 1 ^eM M A I Pp/I I p k .R - R � x I R e R r. a R t J Y N N 1 r �smitr 0� �13 ::a;,. ;'. �4; ..�: ,: c� � � � . ._ � _ - - �, .. ., e� �f �. ..� rq. � I R• '� -ir .. � � �� '" �� u� f �� `�NINtl�r r 9 n�,' �� __-.1 :. _.. �{ l �. x .err- �i' � R j I H {. 1 1 1 1 _ \9 \ 4 s v \ 1 \1 \\ V A. f 6 -' Aj FIELD INSPECTION REPORT � DATE COMMENTS FOUNDATION (1ST) ------- ------------------------------------- FOUNDATION (2ND) vi 1"A- ROUGH FRAMING& Ole, PLUMBING 9-� 63 h26 CD tr7r- INSULATION PER N. Y. STATE ENERGY CODE f-444 FINAL v4 1.471 eAl - ADDITIONAL COMMENTI L( lq 2.5'—Pa4�ot-All!5�a!v EL 0 -q7�?9 5 o -7 F>h 411, y1c v cn ohs°FfOe �o� TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone (631)765-1802 Fax (631) 765-9502 hops://www.southoldtownny.gov Date Received APPLICATION FOR BUILDING PERMIT i I_ I ;: l!� For Office Use Only ! ; PERMIT NO. { Building Inspector: J AN 2 9 2025 r. Applications and forms must be felled out�n their entirety Incomplete �a plications willrinot be.accepted Where the Applicant,is not�the owner,an d .. %•ii:'y ty11 Owner'S'Authonzation form(Page ad sHall be completed Date: 22 JANUARY 2025 OWNER(Stp f,PROPERTY{, Name: MARINOS LILIKAS SCTM#1000- 22. - 2 - 38 Project Address: 505 CEDAR DRIVE EAST MARION, NY 11939 Phone#: Email: MARINOSANNA VERIZON.NET _MailingAddress: 40 DWARS KILL LANE NORWOOD, NJ 07648 CONTACTPERSON n Name: ROBERT I. BROWN ARCHITECT P.C. AND ITS AGENTS Mailing Address: 205 BAY AVE GREENPORT, NY 11944 Phone#: 631-477-9752 Email: INFO@RIBROWNARCHITECT.COM DESIGN PROFESSIONAL INFORMATION 4 , n Name: ROBERT I. BROWN ARCHITECT P.C. AND ITS AGENTS MailingAddress: 205 BAY AVE GREENPORT, NY 11944 Phone#: 631-477-9752 Email: INFO@RIBROWNARCHITECT.COM CONTRACTOR INFORMATION Name: Mailing Address: Phone#: Email: DESCRIPTION OF`YPROPOSED�,`CONSTRUCTION, d ❑New Structure ❑Addition ®Alteration ❑Repair ❑Demolition Estimated Cost of Project: DOther GARAGE AND BASEMENT RENOVATION $ 100,000 Will the lot be re-graded? ❑Yes ®No Will excess fill be removed from premises? ❑Yes ®No 1 t ]� t 9A F ( {7 # : m _' ;� PROPERTI(W�FORMATION � Existing use of property: SINGLE FAMILY RESIDENTIAL Intended use of property: NO CHANGE Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to R_40 this property? Dyes No IF YES, PROVIDE A COPY. Cck BOXAferReadingTheo g wa'ter issues,as provided by Chapter B&of theTo'wn Code:,APPLICATION IS HEREBY MADE to the�Buildmg Department for the issuanco•of a,Building Perin t'pur'suant to the.Building Zone an of e a 11cab a laws Ord ances or Reulations,for the construction of buildin s Otdinance of the Town of Southold,Suffolk,County,Neinr"Y,ork d h r pp c I q , , ad`dttions,-alterations or for feinoval or iiemolitio"nFas herein described The applicarit agrees to comply with all applicable iaws,ordinances,buUdirig code,, L housing coda and regulations�and�to admtt authofized inspectors on Rremises and In buildings)for,necessary inspections False statements made;;herem area punishablelas a CIasS A misdemeanor pursuant't'o'Section;210 45 of the New York State Penal �a Application Submitted By(print name): R N I DO R BAuthorized Agent ❑Owner Signature of Applicant: Date: - Notary Public,State of New York STATE OF NEW YORK) No.01BU6186050 SS: Qualified in Suffolk County Commission Expires April 14,2�dd� COUNTY OF ) RYAN S I DOR being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract) above named, (S)he is the ROBERT I. BROWN ARCHITECT P.C. & ITS AGENTS (Contractor,Agent,Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this (f ,���, T'flay of �/(1n 1Ap1 20� �f 1 �'� Notary Public PROPERTY OWNER AUTHORIZATION (Where the applicant is not the owner) I, MAM05 LKA05 residing at 505 CEZA9- 2-1l C EATENMI210N.Ny 1lc1" do hereby authorize ApaxT 1. � fj Aga a'QF kc. to apply on my ehalf t e o nap South I Building Department for approval as described herei Owner's Signature Date Print Owner's Name 2 �oSuffat � g I ING DEPARTMENT-Electrical Inspector Town TOWN OF SOUTHOLD Hall Annex-'54375 Main Road - PO Box 1179 Dope Southold, New York 11971-0959 gu idin ppsou sfi�hone (631) 765-1802 -FAX (631) 765-9502 `r°'"n Lamesh0southoldtownny-aov - sea ndO-southoldtownnv aov APPLICATION FOR ELECTRICAL INSPECTION JELECTRICIAN INFORMATION (Aii'in't6 mation Required) Date: Company Name: cxg De:Sigo s Electrician's Name: License No.: _ Elec. email: yA Elec. Phone No: I request an email copy of Certificate of Compliance Elec. Address.: eY1+ev- a JOB SITE INFORMATION (All Information Required) Name: q o G re&ar Dri vr-tom Address: 4- On l {9 3 c/ Cross Street: Phone No.: Bldg.Permit#: email: Tax Map District: 1000 Section: Block: Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearty):. 'Square Foota e: Circle All That Apply: Is job ready for inspection?: . YES®NO 2Rough In Final Do you need a Temp Certificate?: YES®NO Issued On Temp Information: (All information required) Service Sizen1 Ph®3 Ph Size: A #Meters Old Meter# [:]New ServiceD Fire Reconnect[]Flood Reconnect OlService Reconnect®Underground 00verhead #Underground Laterals 0 1 2 H Frame Pole Work done on Service? Y nN Additional Information: PAYMENT DUE WITH APPLICATION OHO Electrical Inspector oFFO(,��0 BUILDING DEPARTMENT- TOWN OF SOUTHOLD N x Town Hall Annex- 54375 Main Road - PO Box 1179 ^ Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 ja mesh(ab-southoldtownny.gov - seand(cD-southoldtownny.aov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Company Name: Electrician's Name: License No.: Elec. email: Elec. Phone No: ❑I request an email copy of Certificate of Compliance. Elec. Address.: JOB SITE INFORMATION (All Information Required) Name: Address: SQ C-e dia v- r. ro E _Wl Cross Street: Phone No.: Bldg.Permit#: 04 email: Tax Map District: 1000 Section: Block: Lot: BRIEF DESCRI TION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): A� D GC A vrgr (,� Square Footage: G Circle All That Apply: Is job ready for inspection?: ❑ YES ❑ NO ❑Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES ❑ NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect[:]Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 n2 H Frame Pole Work done on Service? Y FIN Additional Information: PAYMENT DUE WITH APPLICATION PERMIT# Address: Switches ,Outlets GFI's Surface 4 Sconces I H H's t UC Lts Fridge HW POOL Fans Min Panel i Fr. W/D Pump Exhaust Oven Sump Heater Trnsfmr � DW Generator Salt Gen. Smokes!� Carbon Micro GrbDis Water Bond Lights Heat Pucks ., ERV HOT TUB/SPA Inst Hot DeHum Transfer Disc Combo Minisplit Blower 1 , Cookto p AC AH Hood Blower Service Amps �� Have sed Sub Amps Have Used ' Comments �� Generated �&� � =�������� �� "°���x»���—����� �oftware C�(J Compliance Certificate �� �� .��^�q�� � � :�� ������ �� .��� NL�������� NL��x ����� � � ��,� ��� � ����� ����. ~ ~~� � ����� ~~�� Project LILIKAS RENOVATION Energy Code: 2018UECC . _^ Location: Greemport Nemr�ymrk Construction Type: SyagUa'ta �iUy ![ �/ U� Project Type: Addition pu4atSubType: None ��Q — 7 �O9� ' . Climate Zone: � �S��� �K�K�� -- ' �"�o ' . Permit Date: Permit Number _����� �_����� � . . All Electric false Is Renewable false Has Charger false Has Battery: false Has Heat Pump: false Construction Site: Owner/Agent: Designer/Contractor: RIVE MAR|mOSUUKAS ROaERT|. BROWN ARCHITECT P.C. vzl939 z05 BAY AVE GKssmpOnT' Nvz1044 �� 031'477'9752 infn@ribrownarchitect.cum :Compliance: Passes using UA trade-�qff cornn|iance: o.un,Better Than Code wnximvmuA: 78 ,ouruA: zo wax|mumsosc: 0.40 ,nu,sxsc: 0.26 The m Better v,worse Than Code Index reflects how close to compliance the house/s based^"code trade-off rules. u DOES NOT provide ao estimate vr energy use v,cost relative tua minimum-code home. Slab-on-grade tradeoffs are no longer considered in the UA or performance compliance path in REScheck. Each slab-on-grade assembly in the specified climate zone must meet the minimum energy code insulation R-value and depth requirements. Envelope Assemblies Gross Area Cavity Cont. Prop. Req. Prop. Req. Perimeter Ceiling: Cathedral Ceiling 333 49.0 0.0 0.022 8.025 7 9 VVa||: Wood Frame, lb" u.c. 482 15.0 0.0 0.077 0.050 30 Z] Window l' VVund Frame ' 18 0.300 0.320 5 5 SMGC: O.2§ VVindowZ'VVoodprame� 10 O.]OO 0.320 5 5 SHGC: 0.26 VVindm*3�� VVoodFrame 10 0.300 0.320 5 5 5HGC: O.Z§ Window4' VVood �ame� zh 0.300 OJZU 5 5 5HG[: 0.26 Window 5: Wood Frame 16 0300 0.320 5 5 S*GC: 0.Z§ VWnduw0��VVoodFrame lh 0300 0.320 5 5 SHGC: 0.26 Project Title: UUKASRENOVATION Report date: 0307/25 Data filename: Page 1 ufIU Prop.Gross Area Assembly or Cavity Cont. Prop, Perimeter Floor:All-Wood joist/Truss 333 30.0 0.0 0.033 0.047 11 16 Compliance Statement. The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application.The proposed building has been designed to meet the 2018 IECC requirements in REScheck Version : REScheck-Web and to comply with the manda ory requirements listed in the REScheck Inspection Checklist. Name-Title Signa ure Date TT x ,& , Project Title: LILIKAS RENOVATION Report date: 03/07/25 Data filename: Page 2 of10 CREScheck Software Version : REScheck-Web �J( Inspection Checklist Energy Code: 2018 IECC Requirements: 100.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section ;a Plans Verified{ .'field Verified "' 14 4t Req.ID , 'Pre Inspection/Plan"Review Value Value Complies Comments%Assumptions 103.1, Construction drawings and ❑Complies !Requirement will be met. 103.2 1documentation demonstrate � t '❑Does Not [PR111 ;energy code compliance for the i ibuilding envelope.Thermal []Not Observable !envelope represented on ❑Not Applicable ;construction documents. 103.1, ;Construction drawings and ❑Complies ;Requirement will be met. 103.2, 1documentation demonstrate []Does Not 403.7 ;energy code compliance for � d & ;❑Not Observable [PR3]1 ,lighting and mechanical systems ;Systems serving multiple ❑Not Applicable ;dwelling units must demonstrate compliance with the IECC :Commercial Provisions. 302.1 - Heating and cooling equipment is: Heating: Heating: ;❑Complies ;Requirement will be met. 403.7, ',. sized per ACCA Manual S based 1 Btu/hr Btu/hr Z❑Does Not on loads calculated per [PR2J„ P Coolin � Cooling: Manual J or other methods ; g' ❑Not Observable , Btu/hr Btu/hr approved by the code official. 1❑Not Applicable ; I Additional Comments/Assumptions: 11 High Impact(Tier 1) '2" Medium Impact(Tier 2) .11' Low Impact(Tier 3) Project Title: LILIKAS RENOVATION Report date: 03/07/25 Data filename: Page 3 of10 ,Section Foundation`Inspection Fk , Compl�es�} `` Coitimenks/Assumptions 303=: 1 + _A protective covering is installed to I❑Complies ;Exception: Requirement is not applicable. [F011]2 protect exposed exterior insulation E❑Does Not .;' ; and extends a minimum of 6 in. below grade. tlNot Observable I❑Not Applicable 403. C Snow-and ice-melting system controls;❑Complies ;Exception: Requirement is not applicable. [pF012]z installed. ;❑Does Not i; ;❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 2`: Medium Impact(Tier 2) ­3'= Low Impact(Tier 3) Project Title: LILIKAS RENOVATION Report date: 03/07/25 Data filename: Page 4 of10 �Sectib s ,�f -�f did amm I Rou h In Ins ectiort Plans Yer-11 if�ed F�elclVeir►fied� ; �.: 9 9 P Values �Ualue Complies Comitients/Assumptions &.R a .ID � � 402.1.1, ;Glazing U-factor(area-weighted U- ; U- ;❑Complies ;See the Envelope Assemblies 402.3.1, !average). E❑Does Not ;table for values. 402.3.3, I ! 402.5 1 1❑Not Observable [FR2]1 ! { ;❑Not Applicable ; ; 303.1.3 ;U-factors of fenestration products "'* °� ' r ''` ❑Complies ;Requirement will be met. [FR4]1 !are determined in accordance ❑Does Not !with the NFRC test procedure or !taken from the default table. ❑Not Observable , a ;' ❑Not Applicable 402.4.1.1 ;Air barrier and thermal barrier ❑Complies ;Requirement will be met. a [FR23]1 I installed per manufacturer's fit, �' ❑Does Not instructions. ❑Not Observable ! ❑Not Applicable 402.4.3 !Fenestration that is not site built ❑Complies :Requirement will be met. [FR20]1 �is listed and labeled as meeting ❑Does Not AAMA/WDMA/CSA 101/I.S.2/A440 or has infiltration rates per NFRC ❑Not Observable 400 that do not exceed code. ❑Not Applicable limits. ; �d2.4 5 = IC-rated recessed lighting fixtures ❑Complies :Requirement will be met. sealed at housing/interior finish[FR16 ` � 4 '� �;C , ], 9 ❑Does Not ; and labeled to indicate<_2.0 cfm ❑Not Observable leakage at 75 Pa. ❑Not Applicable ; 403.3.1 ;Supply and return ducts in attics ❑Complies ;Requirement will be met. [FR12]1 !insulated >= R-8 where duct is []Does Not I>= 3 inches in diameter and >= , ,R-6 where < 3 inches. Supply and ❑Not Observable ;� `,��, �� � � , !return ducts in other portions of ; ❑Not Applicable ; !the building insulated >= R-6 for )diameter>= 3 inches and R-4.2 '; !for< 3 inches in diameter. ! 403.3.2 ;Ducts, air handlers and filter ❑Complies :Requirement will be met. [FR13]1 !boxes are sealed with �u C Y�� ❑Does Not ljoints/seams compliant with ;International Mechanical Code or []Not Observable ; !International Residential Code, as ❑Not Applicable !applicable. Building cavities are not used as ❑Complies ;Requirement will be met. [FR15]3 ducts or plenums. ❑Does Not 4MWEINot []Not Observable Applicable 403.4 ' `fie HVAC piping conveying fluids R- R- ;❑Complies ;Requirement will be met. [F]117]z '"-above 105 QF or chilled fluids ! ;❑Does Not I I below 55 4F are insulated to >_R- 3 ; ;❑Not Observable ;❑Not Applicable 403.4.1 1 Protection of insulation on HVAC ❑Complies ;Requirement will be met. ❑ [FR24]1 1piping. HE' NEINot Does Not ; ❑Not Observable Applicable 403: :3 Hot water pipes are insulated to ; R- ; R- ;❑Complies !Requirement will be met. [171118]2 >_R-3. ! i 1❑Does Not . ;❑Not Observable ❑Not Applicable 4016 ��Automatic or gravity dampers are n ❑Complies ;Requirement will be met. [FR19]z., )' installed on all outdoor air � ❑Does Not ; _ W intakes and exhausts. ❑Not Observable ❑Not Applicable ; 11 High Impact(Tier 1) "2-1 Medium Impact(Tier 2) Y Low Impact(Tier 3) Project Title: LILIKAS RENOVATION Report date: 03/07/25 Data filename: Page 5 of10 Additional Comments/Assumptions: 11 High Impact (Tier 1) J.,2`1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: LILIKAS RENOVATION Report date: 03/07/25 Data filename: Page 6 of10 sectlonf sn.ti:r �r �'. a t a., a,l � � Plans Verif�etl Field Verified Insulation Inspection Compliesi Comments/Assumptions Value Value ,� ,�.- a u �' -,�;; •.d ,.ors_ a�S + 303.1 " ; All installed insulation is labeled ❑Complies ;Requirement will be met. [013,]2 1•_• or the installed R-values ❑Does Not I provided. .4°�� ❑Not Observable ; ❑Not Applicable 402.1.1, ;Floor insulation R-value. ; R- R- ;❑Complies ;See the Envelope Assemblies 402.2.E { ❑—Wood ❑ Wood :❑Does Not ;table for values. [IN1]1 ❑ Steel ❑ Steel ;❑Not Observable co ❑Not Applicable I I I I i I 1 1 I I 303.2, Floor insulation installed per 1 ❑Complies ;Requirement will be met. 402.2.8 !manufacturer's instructions and ❑Does Not ; [IN2]1 in substantial contact with the underside of the subfloor, or floor ❑Not Observable Iframing cavity insulation is in ❑Not Applicable Icontact with the top side of ; !sheathing, or continuous insulation is installed on they underside of floor framing and extends from the bottom to the 1top of all perimeter floor framing I members. 402.1.1, 1 Wall insulation R-value. If this is a; R I R- I❑Complies ;See the Envelope Assemblies 402.2.5, !mass wall with at least 1/2 of the ❑ Wood ❑ Wood ;❑Does Not table for values. 402.2.6 {wall insulation on the wall {❑ Mass ❑ Mass {❑Not Observable [IN3]1 lexterior,the exterior insulation I requirement applies (FR10). ❑ Steel 1❑ Steel ;❑Not Applicable 1 I i 1 I I 1 I 1 303.2 i Wall insulation is installed per f r rX 3 ' f ❑Complies ;Requirement will be met. [IN4]1 !manufacturer's instructions. ❑Does Not 1 ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) Z Medium Impact(Tier 2) 3. Low Impact(Tier 3) Project Title: LILIKAS RENOVATION Report date: 03/07/25 Data filename: Page 7 of10 � � m; - Plans Uerifietl Pield Verified �-; # Final IiaspectonP,rov,�s�os Value` °f "' :Value ,F Complies' ; ,Comments/Assimptionsi 402.1.1, (Ceiling insulation R-value. ; R- ; R- ;❑Complies ;See the Envelope Assemblies 402.2.1, ;❑ Wood Wood ;❑Does Not :table for values. 402.2.2, I❑ Steel I❑ Steel !❑Not Observable 402.2.6 [Fill' I ; ;❑Not Applicable ; 1 I 1 I 1 i I I I 1 I I 1 I 1 303.1.1.1, ;Ceiling insulation installed per ! ❑Complies ;Requirement will be met. 303.2 !manufacturer's instructions. 4 ° `�� ❑Does Not , [FI2]' ;Blown insulation marked every ; 1300 ft-. ❑Not Observable ❑Not Applicable ; 402.2.3 i Vented attics with air permeable ❑Complies ;Exception: Requirement is [FI22]2 insulation include baffle adjacent ❑Does Not :not applicable. to soffit and eave vents that I ' extends over insulation. ❑Not Observable ; M�� M, ❑Not Applicable ; 402.2.4 ;Attic access hatch and door R- ; R- ;❑Complies ;Requirement will be met. [FI3]' I insulation >_R-value of the ❑Does Not ;adjacent assembly. ; ❑Not Observable ❑Not Applicable 402.4.1.2 `Blower door test @ 50 Pa. <=5 ; ACH 50 = ; ACH 50 = ;❑Complies ;Requirement will be met. [FI17]' ;ach in Climate Zones 1-2, and ElDoes Not ;<=3 ach in Climate Zones 3-8. ; ❑Not Observable ❑Not Applicable 403.3.3 !Ducts are pressure tested to cfm/100 ; cfm/100 ;❑Complies :Exception: Requirement is [FI27]' I determine air leakage with ft2 ft2 ;❑Does Not :not applicable. !either: Rough-in test:Total ;leakage measured with a :❑Not Observable !pressure differential of 0.1 inch I ;❑Not Applicable ; w.g. across the system including ,the manufacturer's air handler I enclosure if installed at time of ;test. Postconstruction test:Total (leakage measured with a 1 I 1 I ! !pressure differential of 0.1 inch w.g. across the entire system lincluding the manufacturer's air I I handler enclosure. I I ! I I 403.3.4 ;Duct tightness test result of<=4 ; cfm/100 ; cfm/100 ;❑Complies ;,Exception: Requirement is [FI4]' (cfm/100 ft2 across the system stem or I ft2 ft2 ❑Does Not not applicable. 1 I<=3 cfm/100 ft2 without air handler @ 25 Pa. For rough-in :❑Not Observable !tests, verification may need to ;❑Not Applicable ;occur during Framing Inspection. 403.3.2.1 ;Air handler leakage designated '( + ' ❑Complies ;Requirement will be met. [F[24]' !by manufacturer at<=2%of ❑Does Not (design airflow. I ❑Not Observable ❑Not Applicable ; 403.1 l,wl,a Programmable thermostats ❑Complies ;Exception: Requirement is installed for control of primary ,� a, ° � ❑Does Not :not applicable. heating and cooling systems and initially set by manufacturer to ❑Not Observable ;. code specifications. ❑Not Applicable ; 4, 3,,; 2 i, Heat pump thermostat installed ❑Complies ;Exception: Requirement is [FI10]2 ""on heat pumps. i ❑Does Not :not applicable. ❑Not Observable ❑Not Applicable 403:5a, - Circulating service hot water ❑Complies :Requirement will be met. systems have automatic or ❑Does Not accessible manual controls. �- ❑Not Observable ; . ❑Not Applicable ; 11 High Impact(Tier 1) r;2. Medium Impact(Tier 2) 11 Low Impact(Tier 3) Project Title: LILIKAS RENOVATION Report date: 03/07/25 Data filename: Page 8 of10 Section, Plans Verified "�Fie1d�Verifietl ` # .:FlihM Inspection Provisions Goinplies?' Comments/Assumptions' Ualue Value 403.6 1 All mechanical ventilation system }.r._ ,` � ❑Complies ;Exception: Requirement is [FI25P- ''fans not part of tested and listed " ��1 []Does Not not applicable. HVAC equipment meet efficacy I and airflow limits per Table ❑Not Observable R403.6.1. ❑Not Applicable 403'.2 Hot water boilers supplying heat ❑Complies ;Exception: Requirement is [Ft26;12 'through one-or two-pipe heating ❑Does Not not applicable. systems have outdoor setback control to lower boiler water []Not Observable temperature based on outdoor M ❑Not Applicable ; temperature. _, „ 403.5.1.1 Heated water circulation systems ` ❑Complies ;Exception: Requirement is [FI28]2 have a circulation pump.The E, ❑Does Not :not applicable. system return pipe is a dedicated return pipe or a cold water supply ❑Not Observable s` pipe.Gravity and thermos- `❑Not Applicable i, syphon circulation systems are not present. Controls for circulating hot water system r , pumps start the pump with signal for hot water demand within the I occupancy. Controls automatically turn off the pump when water is in circulation loop I ; is at set-point temperature and no demand for hot water exists. 403.5.1.2 Electric heat trace systems a❑Complies :Exception: Requirement is [17I29]2 comply with IEEE 515.1 or UL �° � ❑Does Not :not applicable. 515.Controls automatically p adjust the energy input to the ❑Not Observable I heat tracing to maintain the ❑Not Applicable desired water temperature in the ; ;m Piping. 403-.5 2 i�` Demand recirculation water �' ` � ❑Complies ;Exception: Requirement is �� 4f ���` :not applicable. [FI30.]? systems have controls that � � I'I �+ ' ❑Does Not PP manage operation of the pump r and limit the temperature of the ❑Not Observable water entering the cold water ❑Not Applicable piping to <= 1001'. 403.5.4 Drain water heat recovery units ❑Complies ;Exception: Requirement is [FI31]2 tested in accordance with CSA ❑Does Not :not applicable. B55.1. Potable water-side pressure loss of drain water heat �' " ❑Not Observable $ recovery units < 3 psi for ❑Not Applicable individual units connected to one or two showers. Potable water- side pressure loss of drain water heat recovery units < 2 psi for individual units connected to three or more showers. 404.1 190%or more of permanentA_ ❑Complies :Requirement will be met. [FI611 !fixtures have high efficacy lamps _ ❑Does Not i [--]Not Observable i � ❑Not Applicable 404.1 1 Fuel gas lighting systems have ❑Complies :,Exception: Requirement is �[.FI23P, no continuous pilot light. � t -]Does Not not applicable. U ❑Not Observable - ❑Not Applicable 401.3 . �: Compliance certificate posted. �,,�� � � ° ° �"'� ��❑Complies ,Requirement will be met. (FI7]2 ❑Does Not ,'r ❑Not Observable Ah ❑Not Applicable 1 High Impact(Tier 1) 2: Medium Impact(Tier 2) 3:4. Low Impact(Tier 3) Project Title: LILIKAS RENOVATION Report date: 03/07/25 Data filename: Page 9 of10 Section Plans Verified ' Field Verifiletl # .xF�nal InspectionRrov�sions slue Value CompUes� �'Comments/Assumptions & Recj l 303:3 Manufacturer manuals for ❑Com lies p !Requirement will be met. [17118]3 � mechanical and water heating ❑Does Not systems have been provided. ❑Not Observable , ❑Not Applicable Additional Comments/Assumptions: 11 High Impact (Tier 1) 2 Medium Impact(Tier 2) 13': Low Impact(Tier 3) Project Title: LILIKAS RENOVATION Report date: 03/07/25 Data filename: Page 10 of10 2018 IECC Energy Efficiency Certificate Insulation Rating R-Value Above-Grade Wall 15.00 Below-Grade Wall 0.00 Floor 30.00 Ceiling / Roof 49.00 Ductwork (unconditioned spaces): D. . Window 0.30 0.26 Door Heating & Cooling Equipment Efficiency Heating System: Cooling System: Water Heater: Name: Date: Comments i Q ISSUES/REVISIONS RESIDENTIAL GENERAL NOTES MISC. GENERAL NOTES CLIMATIC AND GEOGRAPHIC CRITERIA FROM TABLE N 1 102. 1 .2 (R402. 1 .2) INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENT 1.THI5 PROJECT 15 THE CONSTRUCTION OF AN INTERIOR GARAGE RENOVATION FOR AN EXISTING ONE GROUND 5NOW LOAD 20 PSF (PER FIG. I C08.2 BCNYS 2020 STORY SINGLE FAMILY RESIDENCE,ZONED AS R-40. WIND SPEED(ULTIMATE DESIGN) 130 MPH (PER FIG. I C09.3(I)BCNY5 2020 2.THE EXISTING HEIGHT OF THE STRUCTURE AS DEFINED BY THE BUILDING CODE of NEW YORK STATE SEISMIC DESIGN CATAGORY B (PER SECT. I G 13 BCNYS 2020 2020 15 1 7'-0".THE PROPOSED ADDITION WILL NOT INCREASE THE HEIGHT. WINTER DESIGN TEMP I 1°F (PER TABLE N 1 101.2) ION SKYLIGHT GLAZED BASEMENT SLAB CRAWL APPR VED AS NOTED 3.THE TYPE OF CONSTRUCTION 15 TYPE V(B). FLOOD ZONE N/A (PER FEMA MAP) CLIMATE F=NESTRAT CEILING WOOD FRAME MASS WALL FLOOR 4.ALL WORK SHALL CONFORM TO THE REQUIREMENTS OF THE 2020 BUILDING CODE of NEW YORK FROST LINE DEPTH 3G' FENESTRATIN WALL R-VALUE� SPACE WALL COMPLY WITH ALL CODES D ��e3�5 B,P l WEATHERING PROBABILITY SEVERE (PERBCNY52020 ZONE U-FACTOR U-FACTOR R-VALUE WALL R-VALUE R-VALUE R-VALUE STATE,2020 EXISTING BUILDING CODE of NEW YORK STATE,AND THE AF e PA WOOD FRAME DESIGN LOAD CALCULATIONS (UNIFORM LIVE LOADS) SHGC R-VALUE DEPTH R-VALUE NEW YORK STATE�TOWN CODES CONSTRUCTION MANUAL BUILDING 5 HIGH WIND EDITION. S REOU�RED AND CONDATONS o, 1 e 0681� 5.DESIGN LOAD CALCULATION ARE BASED ON: PER TABLE 1 G07.1 BCNYS 2020 4 0.32 0.55 0.40 49 20 OR 13+5 8/ 13 19 10/ 13 I O, 2FT I 0/ 13 ► � �*.R LIVE LOAD:AS PER TABLE R301.4,BUILDING CODE of NEW YORK STATE 2020. ROOMS OTHER THAN SLEEPING 40 P51 DEAD LOAD:CALCULATED AS PEP R301.3 AS PER BCNYS 2020. SLEEPING ROOMS 30 PSI "�� 1 F ATTICS WITH LIMITED STORAGE 20 P51 4 ' '} 8 cI{ NOTIFY BUILDING DEPARTMENT AT SNOW LOAD:20 P51 GROUND SNOW LOAD(AS PER FIG.R301.2(5)BCNY5 2020. ATTICS WITHOUT STORAGE 10 P51 � j�+�,~!,�+�M„��a LiJ �"i WIND EXPOSURE CATEGORY"C",FOR 130 MPH 3 SECOND GUST. STAIRS 40 PSI Y� 8�1-765-1802 8AM TO 4PM FOR THE ,.,,,,,.,.,d li}e j�'�',"a rJSTEE FOLLOWING INSPECTIONS: LOCATION LIVE DEAD DELECT LIMIT '.YS.C00 FOUNDATION-TWO REQUIRED I ST.FL. 40 LB. 12 U3G0 2ND.FL.(SLEEP AREA) 30 LB. 12 L/3G0 NAILING SCHEDULE v'c�ilti�;�-D��"�• OR POURED CONCRETE 51 ROUGH-FRAMING&PLUMBING ATTIC(NON STORAGE) 20 LB. 10 U3G0 (PER AF t PA AMERICAN WOOD COUNCIL WFCM FOR ROOF 20 LB. 15 U3G0 ONE AND TWO FAMILY DWELLINGS 2015 5BC HIGH WIND EDITION) INSULATION C.THE ARCHITECT ASSUMES NO RESPONSIBILITY FOR THE CONSTRUCTION MEANS,METHODS, JOINT DESCRIPTION NUMBER OF COMMON NAILS NAIL SPACING TECHNIQUES,SEQUENCES,OR PROCEDURES,OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN ROOF FRAMING 13E C •COMPLETE FOR MUST CONNECTION WITH THE WORK. RAFTER TO TOP PLATE(TOE-NAILED) 3 PER RAFTER 8E COMPLETE FOR C.O. THERE ARE NO WARRANTIE5,NOR ANY MERCHANTIBIUTY OF FITNESS FOR A SPECIFIC USE EXPRESSED CEILING JOIST TO TOP PLATE(TOE-NAILED) 3 PER JOINT OR IMPLIED IN THE USE OF THESE PLANS. CEILING JOIST TO PARALLEL RAFTER(FACE-NAILED) 3 EACH LAP LECTRIC/�L Alt CONSTRUCTION SHALL MEET THE 7.CONTRACTOR TO VERIFY ALL DIMENSIONS BEFORE STARTING CONSTRUCTION.DO NOT SCALE CEILING JOIST LAPS OVER PARTITION((FACE-NAILED) 3 EACH LAP INSPECTIOrd REQUIRED OW DIMENSIONS ONLY. RIDGE STRAP(EACH END) 2 PER TIE DRAWINGS.FOLLOW AE�UIREMENTS OF THE CODES OF NEW TO SHALL FURNISH AND INSTALL ALL MATERIAL AND EQUIPMENT SHOWN,LISTED,OR BLOCKING TO RAFTER(TOE-NAILED) 2-8d EACH END YORK STATE. NOT RESPONSIBLE FOR 8.CNGS. RIM BOARD TO RAFTER(END-NAILED) 2-16d EACH END DESIGN OR CONSTRUCTION ERRORS DESCRIBED ON THESE DRAWINGS SUBJECT TO QUALIFICATIONS,CONDITIONS,OR EXCEPTIONS AS WALL FRAM I NG NOTED.CONTRACTOR SHALL FURNISH ALL LABOR,SCAFFOLDING,AND TOOLS NECESSARY TO TOP PLATE TO TOP PLATE(FACE-NAILED) 2-1 Gd PER FOOT COMPLETE THE WORK. TOP PLATES AT INTERSECTIONS(FACE-NAILED) 4-1 Gd J015T EA.51DE 9.ALL MATERIAL SHALL BE INSTALLED IN STRICT CONFORMANCE WITH MANUFACTURES REQUIREMENTS STUD TO STUD(FACE-NAILED) 2-1 Gd 24"O.C. PLUMSER CERTIFICATIOIN p AND SPECIFICATIONS. HEADER TO HEADER(FACE-NAILED) I Gd I G"O.C.ALONG EDGES d V 10.CONTRACTOR SHALL OBTAIN ALL REQUIRED INSPECTIONS,APPROVALS AND CERTIFICATE OF TOP OR BOTTOM PLATE TO STUD(END-NAILED) 2-1 Gd,3-!Gd,4-1 Gd PER 2x4,2xG,2x8 RESPECTIVELY ON LEAD CONTENT BEFOREPIrOV I 5 mok,� Q Carbon OCCUPANCY. BOTTOM PLATE TO FLOOR JOIST,BAND JOIST, CERTIFICATE OF OCCUPANCY rnOnb l de &��RS as ►e u it d END JOIST OR BLOCKING(FACE-NAILED) 2-16d PER FOOT DEMOLITION 1. CONTRACTOR SHALL DEMOLISH EXISTING WALL5,FLOOR,ROOF AND EXISTING RAISED DECK AS FLOOR FRAMING PCC INDICATED ON DRAWINGS AND AS NECESSARY,AND REMOVE ALL DEBRIS. J015T TO SILL,TOP PLATE TO GIRDER(TOE-NAILED) 4-8d PER JOIST 20�O e5id Cod o F IV IN CONTRACTOR SHALL A ALL PATCHING REQUIRED DUE E REMOVAL OF EXISTING WORK AND OF BRIDGING TO JOIST(TOE-NAILED) 2-8d EACH END "'OLDER USED IN ".ATE R YS INSTALLATION OF NEW WORK,AS NECESSARY. BLOCKING TO J015T(TOE-NAILED) 2-8d EACH END 'SUPPLY SYSTEM C�C!PIQT 3. ALL NEW WORK SHALL MATCH AND MEET FLUSH TO EXISTING WORK AS CLOSELY AS POSSIBLE UNLESS BLOCKING TO SILL OR TOP PLATE(FACE-NAILED) 3-I Gd EACH BLOCK 3 I`�� R 315 . OTHERWISE NOTED. LEDGE STRIP TO BEAM(FACE-NAILED) 3-1 Gd EACH JOINT EXCEED 2/10 OF �% LE/ ,D. 4. EXISTING STRUCTURE AND INTERIORS TO REMAIN SHALL BE PROTECTED AS NECESSARY DURING JOIST ON LEDGE TO BEAM(TOE-NAILED) 3-8d PER JOIST DEMOLITION AND CONSTRUCTION. BAND JOIST TO J015T(END-NAILED) 3-I Gd PER JOIST 5. CONTRACTOR SHALL PROTECT EXISTING SERVICES TO REMAIN AND SHALL NOTIFY ALL UTILITIES AND BAND JOINT TO SILL OR TOP PLATE(TOE-NAILED) 2-I Gd PER FOOT TELEPHONE 5ERVICE5 AND MAKE ARRANGEMENTS FOR HOOK-UP,REMOVAL,OR CAPPING OF EQUIPMENT ROOF SHEATHING AS NECESSARY. STRUCURAL PANELS 8d (TABLE ) ALL PLUMBING WASTE DIAGONAL BOARD SHEATHING PLUMBING FOUNDATIONS I NG,OR I"x8" 2-8d PER SUPPORT 1.A55UMED SOIL BEARING CAPACITY, 1,500 Ib./Sq.Ft. I'x 10"OR WIDER 3-8d PER SUPPORT 2.CONCRETE TO BE PLAIN,REINFORCED,3,000 Psi.-28 DAY TEST. &WATER LINES NEED 3.ALL NEW FOOTINGS TO REST ON UNDISTURBED SOIL. CEILING SHEATHING GYPSUM WALLBOARD 5d coolers 7"EDGE/ 10'FIELD TESTING PE FORE COVERING GENERAL CONSTRUCTION WALL SHEATHING 1.PROVIDE ALL LABOR,MATERIALS,TRANSPORTATION,EQUIPMENT AND SERVICES NECESSARY TO STRUCURAL PANEL 8d (TABLE 3.9) COMPLETE ALL WOOD AND PLASTIC WORK REQUIRED BY THE DRAWINGS AS SPECIFIED HEREIN,OR FIBERBOARD PANELS REASONABLY IMPLIED AS NECESSARY TO COMPLETE THE WORK. 2.FASCIAS,SOFFITS AND EXTERIOR TRIM SHALL MATCH EXISTING. 7/1 G" 8d 3"EDGE/G'FIELD 3.INTERIOR TRIM SHALL MATCH EXISTING. 25/32' 8d 3TDGE/G'FIELD 4.FRAMING ELEMENTS: GYPSUM WALLBOARD 5d coolers 7"EDGE/ 1 O"FIELD N 790 1 4'00" E Additional A.ALL FRAMING LUMBER SHALL BE GRADE STAMPED DOUGLAS FIR-LARCH STRUCTURAL GRADE NO.2 HARDBOARD 8d (TABLE 3.9) d�l.><O OR BETTER. PAPTICALBOAPD PANELS 8d (TABLE 3.9) 120.00'B.ALL ENGINEERED LUMBER SHALL BE AS INDICATED ON DRAWINGS,AND SHALL BE INSTALLED,CUT DIAGONAL BOARD SHEATHING - C`Y��+ ~y+�`t AND DRILLED IN SHEATH WG TO BE APA RATED.EXPOSURE ANCE WITH MANUFACTURERS REQUIREMENTSHINE S AS AND NDICATEDCATIONS. 1"XCI OR I IX8" 2-8d PEP SUPPORT I"x 10'OR WIDER 3-861 PER SUPPORT BeRea L�u*� rC(�d . D.ALL SUB FLOORING TO BE APA RATED STUDD-I-FLOOR,EXPOSURE 1,3/4"MIN.THICKNE5. � r E.ALL HEADERS 0-0"AND OVER SHALL BE SUPPORTED WITH DOUBLE UPRIGHTS,9'-0"AND OVER FLOOR SHEATHING WITH TRIPLE UPRIGHTS.ALL HEADERS SHALL BE A MIN.OF(2)2"x8"OR AS SHOWN ON DRAWING. 5TRUCURAL PANELS F.SOLID BLOCKING SHALL BE PROVIDED FOR ALL J015TS AND FLOOR BEAMS AS PER 5CNY5 2020 1"OR LE55 8d G"EDGE/ 12"FIELD OR AS NOTED @ 8'-0"O.C.MIN..PROVIDE 2"SPACE FOR AIR CIRCULATION IN ROOF. GREATER THAN I' I Od G"EDGE/G'FIELD G.PROVIDE DOUBLE FRAMING AROUND ALL OPENINGS(STAIRS,ETC.)OR AS NOTED ON DRAWINGS. DIAGONAL BOARD SHEATHING = _� H.PROVIDE DOUBLE UP FRAMING UNDER ALL POSTS AND PARALLEL PARTITIONS OR AS NOTED ON 1"xG"OR I"x8" 2-8d PER SUPPORT DRAWING. I"x 10"OR WIDER 3-8d PER SUPPORT -' I.ALL FLUSH WOOD CONNECTIONS SHALL BE FASTENED WITH RATED GALVANIZED METAL PROPOSED SLAB CONNECTORS BY'51MP50N"OR APPROVED EQUAL. I AND SPLIT-SYSTEM J.NAILING SCHEDULE SHALL BE AS PER BUILDING CODE of NEW YORK STATE 2020 AS A MINIMUM. I 2 JANUARY,2025 ALL 2"xG"STUDS SHALL RECEIVE(5) 1 Od NAILS AT SILL AND PLATE.ALL EXTERIOR NAILS SHALL BE CON DENSER UNIT GALVANIZED. SEE ATTACHED NAILING SCHEDULE. PROPOSED BASEMENT 15 JANUARY,2025 K.PLYWOOD SHEATHING TO BE NAILED 8d NAILS @ 4"O.C.EXTERIOR EDGES AND Gd NAILS @ 12. O.C.INTERMEDIATE. SEE ATTACHED NAILING SCHEDUI F. // EGRESS WINDOW o3 JANUARY,2025 L.ALL INTERIOR AND EXTERIOR FINISHES TO BE SELECTED BY OWNER. M.ALL ROOF RAFTERS SHALL BE ATTACHED TO THE PLATE AND STUD WITH GALVANIZED HURRICANE TYPE CONNECTORS BY"SIMP50N"OR APPROVED EQUAL.FOR TIMBER PILE FOUNDATIONS,PROVIDE HURRICANE CLIPS AT ALL PERIMETER JOISTS TO GIRDER CONNECTIONS. 24.3' 5.ALL NEW WINDOWS TO BE THERMAL INSULATED LOW-E GLASS,WITH ARGON GAS,IMPACT RESISTANT AS �' P 441-/^7" REQUIRED. THESE PLANS ARE AN INSTRUMENT OF SERVICE G.LOAD PATHS ARE INDICATED BY SECTION DRAWINGS. _ 7.CONNECTIONS SHALL BE BUILT IN ACCORDANCE WITH ANSI/AF A PA WCFM-1995.(5EE NAILING +t AND ARE THE PROPERTY OF THE ARCHITECT. INFRINGEMENTS WILL BE PROSECUTED SCHEDULE) I I 1 8.FLASHING AT ALL WINDOW AND DOOR OPENINGS SHALL BE EPDM OR APPROVED RUBBERIZED MEMBRANE. 2025 ALL RIGHTS RESERVED 9.FLASHING AT ROOF CONNECTIONS,VALLEYS,CHIMNEYS AND CRICKETS SHALL BE ALUMINUM. 10.STEP FLASHING SHALL BE USED AT ALL INTERSECTIONS OF SLOPED AND VERTICAL SURFACES,EXCEPT STEP FLASHING AND COUNTER-AND CAP-FLASHING SHALL BE USED AT INTERSECTION OF ROOF AND /� N CHIMNEY,AND ROOF AND WALL5. N CATED ON THE DPAAING5 AND SHALL BE z1 i/ZINSULATIONb. ENSITY FIBER-GLAS5IBATTS CONFORMING TO THE 5NSULATION OF THICKNESS I ECIFICATION5 FOP PRE OMED FIBROUS CORNER GLA55 INSULATION.NAAMM STANDARD 51, I b-70. CLOSED-CELL SPRAY-IN FOAM INSULATION(R-G.5 PER { r. INCH)BY ICYNENE OR APPROVED EQUAL SHALL BE PROVIDED A5 INDICATED ON DRAWINGS. I I O LD DO WN !2.NEW INTERIOR DOORS SHALL MATCH EXISTING. Robert 1. Brown I 13. NEW HARDWARE SHALL MATCH EXISTING. 14.GYPSUM BOARD SHALL BE EASED EDGE TYPE,CONFORMING TO A5TM C3G,AND SHALL BE 1 '5HEETROCK 5W BY U.S.GYPSUM CO.OR APPROVED EQUAL. GYPSUM WALLBOARD THICKNE55 SHALL BE I . I' Architect, P.C. 1/2" 15.ALL NEW AND REPAIRED GYP.BOARD SHALL BE TAPED AND SPACKLED THREE(3)COATS.ALL EXTERIOR \ 5 CORNERS SHALL HAVE METAL CORNER BEADS. � / � I W Bay Ave. Greenport NY Zo f FINISHES /_/ _ �/ o _ I o _ inPo@ribrownarchitect.com 1. NEW WOOD FLOORS TO BE SELECTED BY OWNER,SANDED AND POLYUR_FTHANE,3 J IJ O _ _ COATS. / \ Icl o EXISTING I-STORY 2. EXISTING WOOD FLOORS SHALL BE SANDED AND REFINI5HED. � O O 631 477 975Z �4, o 0o EXISTING IF STRUCTURE `n WOOD DECK � 3. CERAMIC TILE FLOOR SHALL BE SELECTED BY OWNER AND INSTALLED WITH THIN SET E 0 O ADHESIVE. p _ COVERED 4.EXTERIOR FAINT SHALL BE LATEX ACRYLIC BY BENJAMIN MOORE OR APPROVED _ LOT 38 O O EQUAL,APPLIED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS AND z I PORCH (� E t V E RECOMMENDATIONS. COLOR TO BE SELECTED. I nD ll��J nn 5.EXISTING INTERIOR WALLS AND CEILINGS IN ROOMS AFFECTED BY THE WORK SHALL Q _j ITBE CLEANED AND REPAINTED. NEW WALLS AND CEILINGS SHALL BE SEALED AND RIDGE CROSS SECTION END VIEW U IS A VIOLATION D THE LAW DIRECTION PERSON, PAINTED.PAINTING SHALL BE TWO (2)COATS BENJAMIN MOORE AQUA PEARL LATEX 1 1 UNLESS ACTING UNDER THE DIRECTION M A ft � �I ZO25 LICENSED ARCHITECT,TO ALTER ANY ITEM ON PAINTED,COLOR 7o A SELECTED. THIS DRAWING IN ANY WAY. ANY AUTHORIZED G. INTERIOR TRIM SHALL BE SANDED SMOOTH,PRIMED,AND FINISHED WITH TWO(2) COATS BENJAMIN MOORE LATEX ACRYLIC 5EMI-GLO55 PAINT. ALTERATION BE NOTED, SEALED, DESCRIBED N ACCORDANCE WITH THE LAW HVAC Ciullding D : I.PROVIDE ALL LABOR MATERIALS,TRANSPORTATION,EQUIPMENT AND SERVICES \� / utho^fit ;.A�S NECESSARY TO PROVIDE A NEW SYSTEM TO HEAT AND COOL THE LIVING SPACES AS \ 4- / Trsvfn of SOutt�Oltl _ REQUIRED BY THE DRAWINGS AND SPECIFICATIONS AND THE 2020 MECHANICAL \ CODE of NEW YORK STATE,OR REASONABLY IMPLIED AS NECESSARY TO COMPLETE N PROPOSED To WORK. °° 44'-7" / INTERIOR I'-I" `'y%' $ �� � 2.ABANDON AND REMOVE EXISTING OIL BOILER AND EXISTING OIL TANK. ° C>/� li R^: 3.ABANDON AND REMOVE ALL EXISTING RADIATORS AND NECESSARY PIPING. t I RENOVATION I +/ ��� 4.INSTALL NEW SPLIT SYSTEM AND HEAT PUMPS IN LOCATIONS AS 5HOWN,U51NG EXISTING ASPHALT DRIVEWAY �" � MANUFACTURERS INSTALLATION GUIDES. A/�� PLUMBING - T� 1.PROVIDE ALL LABOR,MATERIALS,TRANSPORTATION, EQUIPMENT,AND SERVICES NECESSARY TO COMPLETE ALL NEW PLUMBING WORK REQUIRED BY THE DRAWINGS AND SPECIFICATIONS AND THE 2020 PLUMBING CODE of NEW YORK STATE,OR REASONABLY IMPLIED AS NECESSARY TO COMPLETE THE WORK. 2.CONFORM TO THE NEW YORK STATE ENVIRONMENTAL CONSERVATION LAW WITH REGARDS TO WATER SAVING AND CONSERVATION. ALL FIXTURES SHALL BE ON THE APPROVED"LIST OF CERTIFIED WATER SAVING PLUMBING FIXTURES"AS PUBLISHED BYE THE NEW YORK STATE DEPARTMENT OF ENVIRONMENTAL CONSERVATION. 3' 3. ALL WORK ON THE PLUMBING SYSTEM SHALL BE PERFORMED BY OR UNDER THE -� SUPERVISION OF A PROPERLY LICENSED MASTER PLUMBER. UPON COMPLETION,THE P PLUMBER SHALL PROVIDE A SOLDER CERTIFICATE AS REQUIRED BY THE TO'NN OF - CLIENT OWNER 4.THE CONTRACTOR SHALL OBTAIN,SUBMIT,AND PAY FOR ALL PERMITS, CERTIFICATIONS,LICENSES AND INSPECTIONS A REQUIRED BY LOCAL STATE,AND , LILIKAS FEDERAL AUTHORITIES,AND ANY OTHER APPLICABLL E JURISDICTION. 5.ABANDON AND REMOVE EXISTING OIL-FIRED WATER HEATER. G.PROVIDE NEW 50 GAL INSTANT ELECTRIC WATER HEATER. Fl.00R ) MARINOS ELECTRICAL J015T I 1.FURNISH ALL LABOR,MATERIALS,EQUIPMENT,PLANT,TOOLS,AND 5ERVICE5 NECESSARY AND REQUIRED FOR PROPER AND COMPLETE INSTALLATION OF ALL NEW - 505 CEDAR DRIVE ELECTRICAL SYSTEMS AND RELATED WORK INCLUDING,BUT NOT LIMITED TO:CONNECT ��--��/�/ - SERVICES, O S TO PRDISOTRIBUTINSTALLED ELECTRICAL SYSTEMS,AND PROTECTION EQUIPMENT,CONNECTIONS NG,LIGHTING, / V' � - - EAST MARION, NY 11939 APPLIANCES, GROUNDING,AND ALL INCLUDING ALL CONNECTIONS AND DEVICES \ S 790 14'OO" W WITHIN THE SCOPE OF THE WORK AS SHOWN ON THE APPLICABLE DRAWINGS AND "' AND 5PCIFICATION5 AND AS NORMALLY SPECIFIED IN THIS TYPE OF PROJECT AND 120.00' PROJECT TITLE INCLUDING CONNECTIONS TO PREVIOUSLY INSTALLED TRANSFORMERS AND ELECTRICAL DISTRIBUTION SYSTEMS. 3 INTERIOR 2.ALL WORK SHALL CONFORM TO THE REQUIREMENTS OF THE 2020 BUILDING CODE � of NEW YORK STATE,THE NATIONAL ELECTRICAL CODE,NFPA NO,70-2017(NEC), SITE PLAN BASED ON SURVEY BY: LOCAL UTILITY STANDARDS,OCCUPATIONAL SAFETY AND HEALTH CAT(OSHA),THE ANDRE K. MILLER PLS NATIONAL ELECTRICAL MANUFACTURERS'ASSOCIATION(NEVIN AND ANY OTHER i--- RENOVATIONS APPLICABLE CODES. IN THE EVENT OF CONFLICT,THE MORE STRINGENT DATED: 5-29-2024 REQUIREMENTS WILL APPLY. = _- SCALE: I" = I O'-O"3.ALL PRODUCTS USED FOR ELECTRICAL WORK SHALL BEAR THE UNDERWRITERS FLOLABORATORIES,INC.LABEL AND BE SUITABLE FOR THE ENVIRONMENT IN WHICH THEY JO15 EXISTING EXCEPT AS NOTED SCTM: 1000-38.-4-27 WILL BE INSTALLED. -- DRAWING TITLE 4.ALL WORK ON THE ELECTRICAL 5Y5TEM SHALL BE PERFORMED BY OR UNDER THEZONED: R-40SUPERVISION OF A PROPERLY LICENSED MASTER ELECTRICIAN.5.THE CONTRACTOR 5HALL OBTAIN,SUBMIT,AND PAY FOR ALL PERMITS,LICENSESAREA: 12,000 SF (0.27 AC) AND INSPECTIONS AS REQUIRED BY THE LOCAL,STATE,AND FEDERAL AUTHORITIES, SITE PLAN AND ANY OTHER APPLICABLE JURISDICTION. G.CARBON MONOXIDE DETECTORS IN CONFORMANCE WITH APPLICABLE CODES 5HALL BE CONNECTED TO THE LIGHTING CIRCUITS WITH NO INTERVENING WALL � ( GENERAL NOTES SWITCH. LINE CORD-CONNECTED,DIRECT PLUG-IN,AND BATTERY POWERED ALARMS ARE NOT ACCEPTABLE. ALARMS SHALL BE INSTALLED ON EACH LEVEL ON WHICH SLEEPING QUARTERS ARE LOCATED. - -r 7.SMOKE DETECTORS IN CONFORMANCE WITH THE 2020 BUILDING CODE of NEW o e YORK STATE,THE NFPA NATIONAL FIRE ALARM CODE NO.72-1993 SHALL BE - UPLIFT CONNECTIONS SCALE PROVIDED OUTSIDE EACH SEPARATE SLEEPING AREA,IN EACH 5PLEEPING AREA,AND ON EACH FLOOR LEVEL. 07 MARCH,2025 1-0 CONTRACTOR SHALL COORDINATE WITH OWNER'S ALARM COMPANY FOR SMOKE AND CONNECTIONS DETAIL 1/4"- BURGLAR ALARMS AS NECESSARY. DRAWING NO. ISSUES/REVISIONS REMOVE EXISTING DOOR NEW CONCRETE BLOCK FOUNDATION WALL TO MATCH EXISTING TO BE FLUSH WITH TOP OF EXISTING CONCRETE WALL WATERPROOFING SEALER BELOW GRADE NEW P.T. SILL PLATE w/FLASHING EXISTING WINDOW EXISTING WINDOW NEW ANCHOR BOLTS @ 24"O.C. w/ TO REMAIN TO REMAIN MINIMUM (1)WITHIN 12"OF CORNER REMOVE EXISTING WINDOW WASHER RYYER REMOVE EXISTING GUT EXISTING CONCRETE WALLLO- � OIL HEATING NEW BASEMENT SYSTEM AND ALL NEW 54" BILCO 5CAPEWEL EGRESS WINDOW d RADIATOR PIPING EGRESS WINDOW 48G2-54 ANDER5EN 400 SERIES w/DOME COVER CXW 145 CASEMENT EXISTING BATHPI OM WINDOW TO REMAIN INSTALLED USING MANUFACTURERS GUIDE WINDOW SILL HEIGHT O - EXISTING TO BE LESS THAN 44" MECHANICAL ROOM SEE DETAIL ON DWG A2 ABOVE FLOOR Ll in in NOTCH EXISTING CONCRETE EXISTING BEDROOM#4 WALL AS NECESSARY FOR EXISTING COLUMNS DROP BEAM TO REMAIN_ _—- - _ - T�— - - _ _�—- - -—� I - _ - _ - NEW(2) 2x8 DROP BEAM EXISTING DROP BEAM TO MAIN i INEW(3) 2x8 FLUSH BEAM FLUSH w/EXISTING FLOOR JOISTS CUT OUT EXISTING FLOOR JOISTS IREPAIR AND PATCH AS NECESSARY I BRACE EXISTING FLOOR w/TEMPORARY COVER EXISTING i SUPPORTS AS NECESSARY i CONCRETE STAIR EXISTING WINDOW EXISTING FINISHED BASEMENT TO REMAIN 3G" HANDRAIL � NEW 2x4 STUD WALL � TO CODE(TYP.) NEW NEW STAIR: 3OG8 EXISTING RISE: 7 Y" ELECTRIC PANEL RUN: 9Y2' (UP RISERS: 12 -JF-r L EXISTING WINDOW TO REMAIN REMOVE EXISTING 2x4 WALL STUDS NEW CONCRETE BLOCK FOUNDATION WALL TO MATCH EXISTING TO BE FLUSH WITH TOP OF EXISTING CONCRETE WALL WATERPROOFING SEALER BELOW GRADE NEW P.T. SILL PLATE w/FLASHING NEW ANCHOR BOLTS @ 24"O.C. w/ MINIMUM (1)WITHIN 12"OF CORNER BASEM ENT PLAN 28 JANUARY,2025 SCALE: 1/4" = I'-0" 15 JANUARY,2025 EXISTING EXCEPT AS NOTED o3 JANUARY,2025 THESE PLANS ARE AN INSTRUMENT OF SERVICE AND ARE THE PROPERTY OF THE ARCHITECT. INFRINGEMENTS WILL BE PROSECUTED 2025 ALL RIGHTS RESERVED 8 EXISTING DECK TO REMAIN T Robert I. Brown Architect, P.C. REMOVE EXISTING DOOR NEW SIDING TO MATCH 205 Bay Ave. Greenport NY NEW 2x4 FRAMED WALL AND OPENINGS EXISTING info@rlbrownarchitect.com NEW ANDERSEN 400 SERIES REPAIR AND PATCH AS 631-477-9752 (3)TW 21052 DOUBLE HUNG WINDOWS NECESSARY WHITE/WHITE EXISTING WINDOW EXISTING WINDOWS EXISTING DOOR NEW WINDOW TRIM TO MATCH EXISTING TO REMAIN TO REMAIN TO REMAIN 3'-I" 3--IN k 4'-1 1/2" IT IS A VIOLATION OF THE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A REMOVE EXISTING BASEBOARD \ REMOVE EX15TING BASEBOARD I I 3'-9" LICENSED ARCHITECT,TO ALTER ANY ITEM ON RADIATOR AND ALL NECESSARY PIPING RADIATOR AND ALL NECESSARY PIPING I I 3" 3" THIS DRAWING IN ANY WAY. ANY AUTHORIZED ALTERATION MUST BE NOTED,SEALED,AND DESCRIBED IN ACCORDANCE WITH THE LAW. I J o m < NEW R-15 BATT INSULATION ,� ."� p '�' EXISTING WINDOW m U IN EXISTING 2x4 WALL CAVITIES `v; s Q w REMOVE EXISTING WALL I �.E sS;4e EXISTING BEDROOM#I w PROVIDE TEMPORARY SUPPORT • ,•;`: TO REMAIN I I z z EXISTING KITCHEN AND BRACING AS NECESSARY PROPOSED LIVING ROOM .. .� t TO REMAIN I I Q TO REMAIN EXISTING GARAGE SLAB TO REMAIN <;tI x o I I NEW 2x8 FLOOR JOISTS , t w Z I I " A^�..w� * k d PLYWOOD > I I NEW FLOORINGTO E SELECTED l W4 00 I I TO BE LEVEL WITH EXISTING FLOOR iuQ II --- � II EXISTING (2) 2x 10 DROP BEAM TO REMAIN I I NEW 4x4 SQUARE COLUMN REMOVE EXISTING WINDOW �� SQUARE PANEL CLADDING FRAME STUD WALL AS NECESSARY CLIENT/OWNER EXISTING COLUMN TO REMAIN I I REMOVE ALL EXISTING DRYWALL ON LI LI WALLS AND CEILING IN NEW AREA I`ll 1� NEW R-1 5 BATT INSULATION IN EXISTING z I I 2x4 WALL CAVITIES � NEW 7.5"CLOSED CELL 5PRAY-IN FOAM MARINOS Q > CUT NEW OPENING FOR BASEMENT STAIR INSULATION (R-49) IN EXISTING m Q 42" KNEE WALL w/FINISHED WOOD CAP I I 2x8 ROOF RAFTER CAVITIES 505 CEDAR DRIVE N N 3G"HANDRAIL TO CODE(fYP.) NEW R 30 BATT INSULATION IN NEW 2x8 m w 4'-7 1/2" 10'-0 I/2" 4'-5" I FLOOR JOISTS EAST MARION, NY 11939 EXISTING WINDOW I NEW R-1 5 BATT INSULATION z _j EXISTING BEDROOM#2 EXISTING BEDROOM#3 3G" HANDRAIL I I REMOVE EXISTING WAIL IN EXISTING 2x4 WALL CAVITIES TO REMAIN Q TO REMAIN TO REMAIN TO CODE(TYP.) I I PROVIDE TEMPORARY SUPPORT PROJECT TITLE Ln AND BRACING AS NECESSARY A w Q ° N NEW STAIR: I I A INTERIOR A3 O M VE EXI TI G B A RUN: 9Yz" I I A3 w Q DI TO A D LL NE ES A Y PI RISERS: 1 2 I I NEW(2) 2x I O HEADER 31, RENOVATIONS o REMOVE EXISTING BASEBOARD I I 3" 3" RADIATOR AND ALL NECESSARY PIPING J,i,(' J,!(" EXISTING WINDOWS TO REMAIN DRAWING TITLE EXISTING WINDOW EXISTING WINDOW 8'-I I" 3'-3" 3'-3" 3'-1 1 1/2" TO REMAIN TO REMAIN 11 EXISTING PORCH TO REMAIN REMOVE EXISTING WALL AS NECESSARY NEW SIDING TO MATCH FLOOR PLAN NEW 2x4 FRAMED WALL AND OPENINGS EXISTING BASEMENT PLAN NEW ANDERSEN 400 SERIES REPAIR AND PATCH AS (3)TW 21052 DOUBLE HUNG WINDOWS NECESSARY WHITE/WHITE NEW WINDOW TRIM TO MATCH EXISTING SCALE FLOOD PLAN 07 MARCH,2025 1/4"=i-o" DRAWING NO. SCALE: 1/4" = 1'-0" EXISTING EXCEPT AS NOTED B SCTM: 1000-22-2-38 A3 ZONED: R-40 i ISSUES/REVISIONS EXISTING ROOF TO REMAIN (2) 2xG P.T. BOX GRADE SLOPED AWAY NEW BASEMENT EGRESS WINDOW NEW 54" BILCO SCAPEWEL —` A ❑ I NEW WINDOW TRIM NEW 51DING TO MATCH ANDERSEN 400 SERIES CXW 145 II I CASEMENT WINDOW EGRESS WINDOW 4862 54 TO MATCH EXISTING EXISTING I�—J ❑ - � w/DOME O REPAIR AND PATCH AS INSTALLED USING — NECESSARY WINDOW SILL HEIGHT I MANUFACTURERS GUIDE TO BE LESS THAN 44 ❑ ABOVE FLOOR N -1 Ell I- -um — — — — — — — — — — — — — — REMOVE EX15TING SIDING AS NECESSARY NEW 51DING TO BE LEVEL WITH EXISTING REMOVE EX15TING 2x4 WALL STUDS S E CT I O' `��I DETAIL NEW CONCRETE BLOCK FOUNDATION WALL TO MATCH EXISTING SCALE: 1/4' = 1'-0" 28 JANUARY,2025 EX15TING EXCEPT AS NOTED WEST ELEVATION (FRONT) 15 JANUARY,zoz5 SCALE: 1/4" = 1'-0" o3 JANUARY,2025 EXISTING EXCEPT AS NOTED THESE PLANS ARE AN INSTRUMENT OF SERVICE AND ARE THE PROPERTY OF THE ARCHITECT. INFRINGEMENTS WILL BE PROSECUTED zoz4 ALL RIGHTS RESERVED Robert I. Brown Architect, P.C. ao Bay Ave. Greenport NY EXISTING ROOFING TO REMAIN in?o@ribrownarchitect.com EXISTING RAFTERS TO REMAIN 631 477-9752 NEW 7.5"CLOSED CELL SPRAY-IN FOAM INSULATION(R-49) IN EXISTING 2x8 ROOF RAFTER CAVITIES i;�',° '_: :' 'r""'t;_ h^.'ry v',' ''. ✓ '.Y_=:v EXISTING ROOFING TO REMAIN IT IS A VIOLATION OF THE LAW FOR ANY PERSON, i � xp EXISTING RAFTERS TO REMAIN "'" UNLESS ACTING UNDER THE DIRECTION OF A EXISTING ROOF TO REMAIN ,.'4;. LICENSED ARCHITECT,TO ALTER ANY ITEM ON NEW 7.5 CLOSED CELL SPRAY-IN FOAM ��:'��� ;,��, CATHEDRAL CEILING INSULATION(R-49) IN EXISTING _ .. THIS DRAWING IN ANY WAY. ANY AUTHORIZED NEW 2x4 STUD WALL EQ E4 I xG NICKLE GAP WOOD PLANK �s zr th ALTERATION MUST BE NOTED,SEALED,AND 2x8 ROOF RAFTER CAVITIES -,ir`'`. CATHEDRAL CEILING ----- -- - -- --- PAINTED WHITE ,�uP I xG NICKLE GAP WOOD PLANKS ``'��., DESCRIBED IN ACCORDANCE WITH THE LAW. Sid.. r=.. '_ 2x 10 COLLAR TIES @ 48"O.C. PAINTED WHITE„�,.- EXISTING CEILING TO REMAIN 515TER EXISTING J015T I BOXED w/ I x 10 WOOD PLANKS NEW 2x8 FLUSH BEAM PAINTED WHITE 2x 10 COLLAR TIES @ 48"O.C. �,�,x •r .�, ..BOXED w/ I x 10 WOOD PLANKS ` 4 ta, .` ';• a AINT REMOVE EXISTING WALL EXISTING(2) 2x 10 DROP BEAM PROVIDE TEMPORARY SUPPORT AND NEW(2) 2x I 0 HEADER(TYP.) NEW(2) 2x 10 HEADER TO REMAIN BRACING AS NECESSARY NEW 4x4 SQUARE COLUMN 5QUARE PANEL CLADDING �, I EXISTING WALL TO REMAIN NEW R-1 5 B M ATT INSULATION IN EXISTING �0 PROPOSED LIVING ROOM REPAIR AND PATCH A5 NECESSARY 2x4 WALL CAVITIESLn NEW 2x8 FLOOR JOISTS NEW SIDING TO MATCH EXISTING NEW 3/4" PLYWOOD SUBPLOOR REPAIR AND PATCH AS NECESSARY EXISTING BEDROOM#2 EXISTING BEDROOM#3 R-30 BATT INSULATIONNEW FLOORING TO BE SELECTED TO REMAIN TO REMAIN CLIENT OWNER TO BE LEVEL WITH EXISTING FLOOR � NEW 2x8 FLOOR JOISTS @ I G"O.C. -..; - ANCHOR NEW FLOOP,J015T REMOVE EXISTING 2x4 WALL 5TUD5 NEW R 30 BAIT INSULATION > .; ?;;^v ?,^ :x ,, c=�: NEW CONCRETE BLOCK FOUNDATION NEW(3) 2x8 DROP SLAM TO STUD WALL WALLT MA .; rrr' : ,,.. :. :,?, } . 'f; sak s:_c .sa-.r• n .t,.; o,.wv :,x; , ,.r.T ;.. LILIKAS EXISTING FLOOR JOISTS TO MAIN J O MATCH EXISTING / TO BE FLUSH WITH TOP OF EXISTING NEW(3) 2x8 DROP BEAM MARINOS (3) 2x8 FLUSH BEAM CONCRETE WALL CUT OUT EXISTING FLOOR JOISTS N EXISTING SLAB TO REMAIN NOTCH EXISTING CONCRETE WATERPROOFING SEALER BELOW GRADE GRADE p REPAIR AND PATCH AS NECESSARY p CLEAN AND DRY WALL AS NECESSARY FOR NEW P.T. SILL PLATE w/FLASHING EXISTING SLAB TO REMAIN 505 CEDAR DRIVE BRACE EXISTING FLOOR w/TEMPORARY DROP BEAM NEW ANCHOR BOLTS @ 24"O.C. w/ CLEAN AND DRY SUPPORTS AS NECESSARY NEW BASEMENT STAIR: MINIMUM (1)WITHIN 1 2'OF CORNER EAST MARION, NY 11939 RISE: 7 " RUN: 9'/2" EXISTING FOUNDATION PROJECT TITLE RISERS: 12 WALLS TO REMAIN EXISTING FOUNDATION SECTION D TO REMAIN I NTE RI O R EXISTING FOUNDATION SCALE: 1/4" = 1'-0" RENOVATIONS WALLS TO REMAIN EXISTING FOUNDATION EXISTING EXCEPT AS NOTED WALLS TO REMAIN SECTION � ABANDON EXISTING STAIR DRAWING TITLE SCALE: 1/4" = I'-O" ELEVATIONS EXISTING EXCEPT AS NOTED SECTIONS SCALE o7 MARCH,2025 1/4"=i-o" I DRAWING NO. I ISSUES/REVISIONS v® � qp 9 REMOVE EXISTING OIL NEW SPLIT SYSTEM HEATING SYSTEM AND ALL ZONE (3) RADIATOR PIPING ->< WASHER DRYER REMOVE EXISTING OIL TANK REMOVE EXISTING OIL-FIRED WATER HEATER EXISTING LIGHT NG EXISTING LIGHTING TO REMAIN NEW 50 GAL INSTANT ELECTRIC WATER HEATER TO REMAIN O SD CO m m EXISTING LIGHTING TO REMAIN I d UPGRADE EXISTING _ I TO PSTAIRS ELECTRIC PANEL � S ETCH ELECTRICAL LEGEND NEW SPLIT SYSTEM SD COO 3 O � i ZONE (3) ® LIGHT SWITCH 3 = THFEE WAY D = DIMMER ® JAM SWITCH OUTLET GFI= GROUND FAULT INTEKUPT 220 = 220 VOLT 4 = QUAD OUTLET FIXTURE : S= SURFACE MOUNT PROVIDED BY OWNER R= RECESSED PROVIDED BY CONTRACTOR FO WALL SCONCE HOSE BASEMENT ELECTRICAL PLAN < PHONE BIBS SCALE: 1/4" = P-0" O— CABLE 5E NETWORK CABLE EXISTING EXCEPT AS NOTED Q SPEAKERS 4 ALARM KEYPAD 28 JANUARY,2025 4 THERMOSTAT 15 JANUARY,2025 ® VENT THESE PLANS ARE AN INSTRUMENT OF SERVICE AND ARE THE PROPERTY OF THE ARCHITECT. SD CO CARBON MONOXIDE DETECTOR INFRINGEMENTS WILL BE PROSECUTED EPH ELEC. PANEL HEATER 2025 ALL RIGHTS RESERVED PHONE/COMM. LIGHT TRACK PC PULL CHAIN Robert I. Brown FL PORTRAIT LIGHT 5'G"TO CLOCK OUTLET Architect, P.C. ,r DIRECT LIGHTING 20 Bay Ave. Greenport NY REMOVE EXISTING --� in o ribrownarchitect.com �.j BASEBOARD RADIATOR AND I G' FLUORESCENT 631-477-9752 `r ALL NECESSARY PIPING SPOTLIGHT REMOVE EXISTING BASEBOARD ®$ i RADIATOR AND ALL NECESSARY PIPING NEW SPLIT SYSTEM IT IS A VIOLATION OF THE LAW FOR ANY PERSON, ZONE(2) UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT,TO ALTER ANY ITEM ON HANGING LIGHT THIS DRAWING IN ANY WAY. ANY AUTHORIZED 0 O z /�' `(� FIXTURES ALTERATDESCRIBED INAC ACCORDANCE WITH ON MUST BE NOTED, LTHE� � az / \ z z 0 !�: / 1 x 0 MEXISTING LIGHTING ,u QQ u0 TO REMAINLu LU NEW SPLIT SYSTEM ,L, 0 z ZONE(1) °L Cu J 6 HANGING LIGHT Q Q FIXTURES �• CD rj n r L—00 EXISTING LIGHTING TO REMAIN CLIENT/OWNER SD CO ` �`r' Y\ FIXTURES LIGHT o NEW SPLIT SYSTEM Lj I / \ L I L I K-A-S Q O ZONE(1) Sp SD CO f \ z o L c0 T, MARINOS O X Q - + �\ 505 CEDAR DRIVE w HANGING LIGHT w0ui z EAST MARION, NY 11939 > CZ Q FIXTURES I ( _ \ z ( i Lu w \ PROJECT TITLE Q Q NEW SPLIT SYSTEM TO DOWNSTAIRS / NEW SPLIT SY4EM m ZONE(I) SWITCH �� ZONE(2) ER 3 INTERIOR REMOVE EXISTING BASEBOARD I RENOVATIONS REMOVE EXISTING RADIATOR AND ALL NECESSARY PIPING BASEBOARD RADIATOR AND ALL NECESSARY PIPING DRAWING TITLE ELECTRICAL PLAN FI RST FLOOD ELECTRI CAL PLAN SCALE SCALE: 1/4" = 1'-0" 07 MARCH,zoa5 1/4,=i-o' EXISTING EXCEPT AS NOTED DRAWING NO.