HomeMy WebLinkAbout51724-Z ho0,4�oF SOpTyo�° Town of Southold
* * P.O. Box 1179
,0 53095 Main Rd
orm Southold, New York 11971
CERTIFICATE OF OCCUPANCY
No: 46438 Date: 08/22/2025
THIS CERTIFIES that the building SINGLE FAMILY DWELLING-ALTERATION
Location of Property: 505 Cedar Dr East Marion, NY 11939
Sec/Block/Lot: 22.-2-3 8
Conforms substantially to the Application for Building Permit heretofore,filed in this office dated: 01/29/2025
Pursuant to which Building Permit No. 51724 and dated: 03/11/2025
Was issued, and conforms to all of the requirements of the applicable provisions of the law.
The occupancy for which this certificate is issued is:
Alterations including conversion of attached garage to living space and "as built" finished
basement with bath to existing single-family dwelling as applied for.
The certificate is issued to: Marinos Lilikas , Anna Lilikas
Of the aforesaid building.
SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL:
ELECTRICAL CERTIFICATE: 51724 8/7/2025
PLUMBERS CERTIFICATION: Gemini Plumbing LLC 8/22/2025
� AuVinze Signature
�o��ofSOUryolo TOWN OF SOUTHOLD
BUILDING DEPARTMENT
TOWN CLERK'S OFFICE
eo I SOUTHOLD, NY
BUILDING PERMIT
(THIS PERMIT MUST BE KEPT ON THE PREMISES
WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS
UNTIL FULL COMPLETION OF THE WORK AUTHORIZED)
Permit#: 51724 Date: 03/11/2025
Permission is hereby granted to:
Marinos Lilikas
505 Cedar Dr
East Marion, NY 11939
To:
Legalize an "as built"finished basement and construct alterations to convert the attached garage to
living space, relocate the interior basement stairs and install HVAC split system to an existing single-
family as applied for. Additional certification may be required.
Premises Located at:
505 Cedar Dr, East Marion, NY 11939
SCTM#22.-2-38
Pursuant to application dated 01/29/2025 and approved by the Building Inspector.
To expire on 03/11/2027.
Contractors:
Required Inspections:
Fees:
As Built Alteration $1,380.00
Single Family Dwelling- Alteration $161.00
CO Single Family Dwelling-Addition/Alteration $100.00
Total $1,641.00
--Ji2
Building Inspector
o��pF S0(/T�,QI
� o
Town Hall Annex Telephone(631)765-1802
54375 Main Road
P.O.Box 1179 G • Q
Southold,NY 11971-0959 �Q
�yenU ,N
BUILDING DEPARTMENT
TOWN OF SOUTHOLD
CERTIFICATE OF ELECTRICAL COMPLIANCE
SITE LOCATION
Issued To: Marinos Lilikas
Address: 505 Cedar Dr City: East Marion St: NY Zip: 11939
Building Permit t 51724 Section: 22 Block: 2 Lot: 38
WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE
Contractor: Electrician: AS BUILT License No:
SITE DETAILS
Office Use Only
Indoor r�71. Basement rv-- Service [✓ Solar F
Outdoor r— 1st Floor r Pool r Spa 17-
Renovation F 2nd Floor 177 Hot Tub r Generator F
Survey r Attic (- Garage Battery Storage (—
INVENTORY
Service 1 ph r- Heat Duplec Recpt 5 Ceiling Fixtures Bath Exhaust Fan
Service 3 ph F Hot Water GFCI Recpt 2 Wall Fixtures Smoke Detectors 4
Main Panel 200A A/C Condenser Single Recpt Recessed Fixtures 10 CO Detectors
Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO 2
Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors 1
Disconnect Switches 4 4'LED Exit Fixtures
Other Equipment: 200A Panel 40 Circuits / 24 Used
Notes: � AS BUILT NO VISUAL DEFECTS " Garage Converted to Living Space & Finished
Basement
Inspector Signature: Date: August 7, 2025
Sean Devlin ellx
Electrical Inspector sean.devlin(cD-town.southold.ny.us
505CedarBasement&Garage2 Liv
Town Hall Annex �®� ® l4o 4�91pl)765-1802
54375 Main Road
P. 0. Box 1179 ®
Alt
Southold, NY 11971-0959 W ® A ,
No 2 2 2025
1 �'tme "�
B uElding D-P
Town�9( -bOU��^tbjE9
BUILDING DEPARTMENT
TOWN OF SOUTHOLD
CERTIFICATION
Date: ':� 22 jo 1.5
Building Permit No. 1 ��
Owner: L A .�
(Please print)
Plumber: e lyl���? ) eztJm I j 7 yI C
(Please print)
I certify that the solder used in the water supply system contains less than 2/10 of 1% lead.
Oda C� (/u rU
(Plumbers Signature)
Sworn to before me this a �"
day of 1� 20
44
Notary Public, County
PENNY BEDELL
Notary Public,State of blew York:
No.01 BE6099317
Qualified in Suffolk County
Commission Expires Sept.29,
1
laf so
7��o
SOUTHOLD BUILDING DEPT.
631-765-1802
INSPECTION
[ ] FOUNDATION:1 ST/ REBAR [ ] ROUGH PLBG.
[ -] FOUNDATION 2ND = [ ] 'INSULATION/CAULKING
[ ] FRAMING/STRAPPING [ ] FINAL
[ } FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION
[ ..] FIRE RESISTANT-CONSTRUCTION [ ] FIRE-RESISTANT PENETRATION
[ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL)
[ ] CODE VIOLATION- [ ] PRE C/O [ ] 'RENTAL
REMARKS:
DATE INSPECTOR
.. ✓ , f N\OF SOUTyO�
I # * TOWN-OF SOUTHOLD BUILDING DEPT. .
utN 631-765-1802
INSPECTION
[ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG.
[ ] FOUNDATION 2ND [ ] INSULATION/CAULKING
[vj FRAMING /STRAPPING [ ] FINAL
[ ] FIREPLACE & CHIMNEY- [ ] FIRE SAFETY INSPECTION
[ ] FIRE-RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION
[ ] 'ELECTRICAL (ROUGH) [ ]. ELECTRICAL (FINAL)
[ ] CODE VIOLATION [ ] PRE C/O [ ]. RENTAL
REMARKS_: &d"L4 7"b
Q-o 14A4 n im&W_
DATE ANSPECTOR
SOl/ThO�o
# # TOWN OF SOUTHOLD BUILDING DEPT.
o�y o MV,��o 631-765-1802
INSPECTION
[ ] FOUNDATION 1 ST/REBAR [ ] ROUGH PLBG.
[ ] FOUNDATION 2ND I INSULATION/CAULKING
[ ] FRAMING /STRAPPING [ ] FINAL
[ . ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION
[ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL)-
CODE VIOLATION [ ]. PRE C/O [ ] RENTAL
REMARKS: Av,.c.Lq'& L /!.5u �
vkf oo l'y,s-& j_k, Oy ere'.0
SATE 7 INSPECTOR
SOUTyOIo /�� L) C��
# # AWN Of SOUTHOLD BUILDING
cou 631-765-1802
INSPECTION
[ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG.
[ ] FOUNDATION 2ND [ ] INSULATION/CAULKING
[ ] FRAMING /STRAPPING [ ] FINAL
[ ]- FIREPLACE,& CHIMNEY [ ] FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION
[ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL)
[ ] CODE VIOLATION ] PRE C/O�y [ ]. RENTAL
REMARKS. S�)V) ko"T ' &�7 WIA
zj bc,feo
eA wt /I Pe -_ Ao k\atV
b(Il LAS � qe -jTJp `
DATE INSPECTOR �51_�l
a SOGIyo�
# . TOWN OF SOUTHOLD BUILDING DEPT.
631-765-1802
-.INSPECTION
].- FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG.
[ ] FOUNDATION 2ND [ �FINAL
LATION/CAULKING
FRAMING/STRAPPING [
[ ] FIREPLACE & CHIMNEY [ ] FIRE'SAFETY INSPECTION
[ ] FIRE`RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION
[ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL)
[ ]- CODE VIOLATION. [ ] PRE.C/O [ ] RENTAL
I�SKS. ti intAW
�,
v s
_Otl 4
DATE ANSPECTOR
OF SO�Th°�
* TOWN OF SOUTHOLD BUILDING DEPT.
utm� 631-765-1802
INSPECTION
[ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG.
[ ] FOUNDATION 2ND [ ] I LATIIAe-
OW1 LKING
[ ] FRAMING/STRAPPING [ FINAL '�,(
[ ] FIREPLACE & CHIMNEY f ] FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT- CONSTRUCTION ' [ ] FIRE RESISTANT PENETRATION
[ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) -
[ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL
REM RKS:
DATE INSPECTOR
Robert I. Brown Architect, P.C.
205 Bay Avenue,Greenport, NY 11944
info@ribrownarchitect.com
631-477-9752
22 May, 2025
Town of Southold Building Department
Southold,NY 11971
Re: Lilikas Residence
505 Cedar Drive
East Marion,NY 11939
Building Permit No. 51724
To whom it may concern,
This letter is to confirm that based on observations of the site by my staff, and to the best
of my knowledge, belief, and professional judgement, the new insulation is installed in all
opened and modified exterior structural elements and is as stated,-
2x4 walls; R-13 batt insulation
2x10 floor; R-30 batt insulation
2x8 ceiling; R-19 batt insulation
If you have any questions, or require additional information, please feel free to contact
me.
Sincerel -,_
� D
M AY 2 3 2025
Building Department
'town of Southold
Robert Brown, A.I.A.
j,
i
T —
F_
A
r l
,
• 13 l�i� r � 9^E 1! � fil�l� :�4�fi i�
'• r 9
P110E IVA ii !! 'i i —— -----
h ------ e `
t I NE
L+
-----
,
sz 24442
1
l if "ry I a-- x0' �IIIt�I it
._
----
I� rr
—
I
i.
m -
n
m
•n
1
`s.
J u
r
a
r
m
N
+a
�y
N
,a
f
a
0
,d
m
�i
40 .n
.n
N
~ ...-
h 4
h
a ECEU VE
2025
BuiIding Department
Town of Southold
a
'm
I 9
I
,G
R
• y
li ny
BBB, wry
^(r
1 ^eM
M
A I
Pp/I
I
p
k
.R
- R �
x I
R e
R
r.
a
R
t
J
Y
N
N
1
r �smitr
0�
�13
::a;,. ;'.
�4;
..�:
,:
c�
� � � . ._
� _
- -
�,
..
., e�
�f �.
..� rq. � I
R• '�
-ir
.. � � ��
'"
��
u�
f
�� `�NINtl�r
r 9
n�,'
�� __-.1 :. _..
�{ l �.
x .err- �i' � R
j I
H
{. 1
1 1
1
_ \9 \
4
s
v
\
1 \1 \\
V A.
f
6
-' Aj
FIELD INSPECTION REPORT � DATE COMMENTS
FOUNDATION (1ST) -------
-------------------------------------
FOUNDATION (2ND)
vi 1"A-
ROUGH FRAMING& Ole,
PLUMBING
9-�
63
h26 CD
tr7r-
INSULATION PER N. Y.
STATE ENERGY CODE
f-444
FINAL
v4
1.471
eAl
-
ADDITIONAL COMMENTI
L(
lq 2.5'—Pa4�ot-All!5�a!v EL 0 -q7�?9 5
o
-7 F>h 411, y1c
v
cn
ohs°FfOe �o� TOWN OF SOUTHOLD—BUILDING DEPARTMENT
Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959
Telephone (631)765-1802 Fax (631) 765-9502 hops://www.southoldtownny.gov
Date Received
APPLICATION FOR BUILDING PERMIT
i I_ I ;:
l!�
For Office Use Only ! ;
PERMIT NO. { Building Inspector:
J AN 2 9 2025 r.
Applications and forms must be felled out�n their entirety Incomplete
�a plications willrinot be.accepted Where the Applicant,is not�the owner,an
d .. %•ii:'y ty11
Owner'S'Authonzation form(Page ad sHall be completed
Date: 22 JANUARY 2025
OWNER(Stp f,PROPERTY{,
Name: MARINOS LILIKAS SCTM#1000- 22. - 2 - 38
Project Address: 505 CEDAR DRIVE EAST MARION, NY 11939
Phone#: Email: MARINOSANNA VERIZON.NET
_MailingAddress: 40 DWARS KILL LANE NORWOOD, NJ 07648
CONTACTPERSON n
Name: ROBERT I. BROWN ARCHITECT P.C. AND ITS AGENTS
Mailing Address: 205 BAY AVE GREENPORT, NY 11944
Phone#: 631-477-9752 Email: INFO@RIBROWNARCHITECT.COM
DESIGN PROFESSIONAL INFORMATION
4 ,
n
Name: ROBERT I. BROWN ARCHITECT P.C. AND ITS AGENTS
MailingAddress: 205 BAY AVE GREENPORT, NY 11944
Phone#: 631-477-9752 Email: INFO@RIBROWNARCHITECT.COM
CONTRACTOR INFORMATION
Name:
Mailing Address:
Phone#: Email:
DESCRIPTION OF`YPROPOSED�,`CONSTRUCTION,
d
❑New Structure ❑Addition ®Alteration ❑Repair ❑Demolition Estimated Cost of Project:
DOther GARAGE AND BASEMENT RENOVATION $ 100,000
Will the lot be re-graded? ❑Yes ®No Will excess fill be removed from premises? ❑Yes ®No
1
t ]� t 9A F ( {7 #
: m _' ;� PROPERTI(W�FORMATION �
Existing use of property: SINGLE FAMILY RESIDENTIAL Intended use of property: NO CHANGE
Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to
R_40 this property? Dyes No IF YES, PROVIDE A COPY.
Cck BOXAferReadingTheo g wa'ter issues,as provided by
Chapter B&of theTo'wn Code:,APPLICATION IS HEREBY MADE to the�Buildmg Department for the issuanco•of a,Building Perin t'pur'suant to the.Building Zone
an of e a 11cab a laws Ord ances or Reulations,for the construction of buildin s
Otdinance of the Town of Southold,Suffolk,County,Neinr"Y,ork d h r pp c I q , ,
ad`dttions,-alterations or for feinoval or iiemolitio"nFas herein described The applicarit agrees to comply with all applicable iaws,ordinances,buUdirig code,, L
housing coda and regulations�and�to admtt authofized inspectors on Rremises and In buildings)for,necessary inspections False statements made;;herem area
punishablelas a CIasS A misdemeanor pursuant't'o'Section;210 45 of the New York State Penal
�a
Application Submitted By(print name): R N I DO R BAuthorized Agent ❑Owner
Signature of Applicant: Date:
-
Notary Public,State of New York
STATE OF NEW YORK) No.01BU6186050
SS: Qualified in Suffolk County
Commission Expires April 14,2�dd�
COUNTY OF )
RYAN S I DOR being duly sworn, deposes and says that(s)he is the applicant
(Name of individual signing contract) above named,
(S)he is the ROBERT I. BROWN ARCHITECT P.C. & ITS AGENTS
(Contractor,Agent,Corporate Officer, etc.)
of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this
application;that all statements contained in this application are true to the best of his/her knowledge and belief; and
that the work will be performed in the manner set forth in the application file therewith.
Sworn before me this (f ,���,
T'flay of �/(1n 1Ap1 20� �f 1 �'�
Notary Public
PROPERTY OWNER AUTHORIZATION
(Where the applicant is not the owner)
I, MAM05 LKA05 residing at 505 CEZA9- 2-1l C EATENMI210N.Ny 1lc1"
do hereby authorize ApaxT 1. � fj Aga a'QF kc. to apply on
my ehalf t e o nap South I Building Department for approval as described herei
Owner's Signature Date
Print Owner's Name
2
�oSuffat � g I ING DEPARTMENT-Electrical Inspector
Town
TOWN OF SOUTHOLD
Hall Annex-'54375 Main Road - PO Box 1179
Dope
Southold, New York 11971-0959
gu idin ppsou sfi�hone (631) 765-1802 -FAX (631) 765-9502
`r°'"n Lamesh0southoldtownny-aov - sea ndO-southoldtownnv aov
APPLICATION FOR ELECTRICAL INSPECTION
JELECTRICIAN INFORMATION (Aii'in't6 mation Required) Date:
Company Name: cxg De:Sigo s
Electrician's Name:
License No.: _ Elec. email: yA
Elec. Phone No: I request an email copy of Certificate of Compliance
Elec. Address.: eY1+ev- a
JOB SITE INFORMATION (All Information Required)
Name: q o G re&ar Dri vr-tom
Address: 4- On l {9 3 c/
Cross Street:
Phone No.:
Bldg.Permit#: email:
Tax Map District: 1000 Section: Block: Lot:
BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearty):.
'Square Foota e:
Circle All That Apply:
Is job ready for inspection?: . YES®NO 2Rough In Final
Do you need a Temp Certificate?: YES®NO Issued On
Temp Information: (All information required)
Service Sizen1 Ph®3 Ph Size: A #Meters Old Meter#
[:]New ServiceD Fire Reconnect[]Flood Reconnect OlService Reconnect®Underground 00verhead
#Underground Laterals 0 1 2 H Frame Pole Work done on Service? Y nN
Additional Information:
PAYMENT DUE WITH APPLICATION
OHO Electrical Inspector
oFFO(,��0 BUILDING DEPARTMENT-
TOWN OF SOUTHOLD
N x Town Hall Annex- 54375 Main Road - PO Box 1179
^ Southold, New York 11971-0959
Telephone (631) 765-1802 - FAX (631) 765-9502
ja mesh(ab-southoldtownny.gov - seand(cD-southoldtownny.aov
APPLICATION FOR ELECTRICAL INSPECTION
ELECTRICIAN INFORMATION (All Information Required) Date:
Company Name:
Electrician's Name:
License No.: Elec. email:
Elec. Phone No: ❑I request an email copy of Certificate of Compliance.
Elec. Address.:
JOB SITE INFORMATION (All Information Required)
Name:
Address: SQ C-e dia v- r. ro E _Wl
Cross Street:
Phone No.:
Bldg.Permit#: 04 email:
Tax Map District: 1000 Section: Block: Lot:
BRIEF DESCRI TION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly):
A� D GC A vrgr (,�
Square Footage: G
Circle All That Apply:
Is job ready for inspection?: ❑ YES ❑ NO ❑Rough In ❑ Final
Do you need a Temp Certificate?: ❑ YES ❑ NO Issued On
Temp Information: (All information required)
Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter#
❑New Service❑Fire Reconnect[:]Flood Reconnect❑Service Reconnect❑Underground❑Overhead
# Underground Laterals 1 n2 H Frame Pole Work done on Service? Y FIN
Additional Information:
PAYMENT DUE WITH APPLICATION
PERMIT# Address:
Switches
,Outlets
GFI's
Surface 4
Sconces I
H H's t
UC Lts Fridge HW POOL
Fans Min Panel
i Fr. W/D Pump
Exhaust Oven Sump Heater
Trnsfmr
� DW Generator Salt Gen.
Smokes!�
Carbon Micro GrbDis Water Bond
Lights
Heat Pucks ., ERV
HOT TUB/SPA
Inst Hot DeHum Transfer Disc
Combo Minisplit Blower
1 , Cookto p
AC AH Hood Blower
Service Amps �� Have sed
Sub Amps Have Used '
Comments ��
Generated �&� �
=�������� �� "°���x»���—����� �oftware
C�(J Compliance
Certificate
��
�� .��^�q�� � � :�� ������ �� .��� NL�������� NL��x
����� � � ��,� ��� � ����� ����. ~ ~~� � ����� ~~��
Project LILIKAS RENOVATION
Energy Code: 2018UECC . _^
Location: Greemport Nemr�ymrk
Construction Type: SyagUa'ta �iUy ![ �/ U�
Project Type: Addition
pu4atSubType: None ��Q — 7 �O9� ' .
Climate Zone: � �S��� �K�K�� -- ' �"�o '
.
Permit Date:
Permit Number
_����� �_�����
� . .
All Electric false
Is Renewable false
Has Charger false
Has Battery: false
Has Heat Pump: false
Construction Site: Owner/Agent: Designer/Contractor:
RIVE MAR|mOSUUKAS ROaERT|. BROWN ARCHITECT P.C.
vzl939 z05 BAY AVE
GKssmpOnT' Nvz1044
�� 031'477'9752
infn@ribrownarchitect.cum
:Compliance: Passes using UA trade-�qff
cornn|iance: o.un,Better Than Code wnximvmuA: 78 ,ouruA: zo wax|mumsosc: 0.40 ,nu,sxsc: 0.26
The m Better v,worse Than Code Index reflects how close to compliance the house/s based^"code trade-off rules.
u DOES NOT provide ao estimate vr energy use v,cost relative tua minimum-code home.
Slab-on-grade tradeoffs are no longer considered in the UA or performance compliance path in REScheck. Each slab-on-grade
assembly in the specified climate zone must meet the minimum energy code insulation R-value and depth requirements.
Envelope Assemblies
Gross Area Cavity Cont. Prop. Req. Prop. Req.
Perimeter
Ceiling: Cathedral Ceiling 333 49.0 0.0 0.022 8.025 7 9
VVa||: Wood Frame, lb" u.c. 482 15.0 0.0 0.077 0.050 30 Z]
Window l' VVund Frame
' 18 0.300 0.320 5 5
SMGC: O.2§
VVindowZ'VVoodprame� 10 O.]OO 0.320 5 5
SHGC: 0.26
VVindm*3�� VVoodFrame
10 0.300 0.320 5 5
5HGC: O.Z§
Window4' VVood �ame� zh 0.300 OJZU 5 5
5HG[: 0.26
Window 5: Wood Frame
16 0300 0.320 5 5
S*GC: 0.Z§
VWnduw0��VVoodFrame
lh 0300 0.320 5 5
SHGC: 0.26
Project Title: UUKASRENOVATION Report date: 0307/25
Data filename: Page 1 ufIU
Prop.Gross Area
Assembly or Cavity Cont. Prop,
Perimeter
Floor:All-Wood joist/Truss 333 30.0 0.0 0.033 0.047 11 16
Compliance Statement. The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application.The proposed building has been designed to meet the 2018 IECC requirements in
REScheck Version : REScheck-Web and to comply with the manda ory requirements listed in the REScheck Inspection Checklist.
Name-Title Signa ure Date
TT
x ,&
,
Project Title: LILIKAS RENOVATION Report date: 03/07/25
Data filename: Page 2 of10
CREScheck Software Version : REScheck-Web
�J( Inspection Checklist
Energy Code: 2018 IECC
Requirements: 100.0% were addressed directly in the REScheck software
Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Section ;a Plans Verified{ .'field Verified "'
14
4t Req.ID ,
'Pre Inspection/Plan"Review Value Value Complies Comments%Assumptions
103.1, Construction drawings and ❑Complies !Requirement will be met.
103.2 1documentation demonstrate � t '❑Does Not
[PR111 ;energy code compliance for the i
ibuilding envelope.Thermal []Not Observable
!envelope represented on ❑Not Applicable
;construction documents.
103.1, ;Construction drawings and ❑Complies ;Requirement will be met.
103.2, 1documentation demonstrate []Does Not
403.7 ;energy code compliance for � d &
;❑Not Observable
[PR3]1 ,lighting and mechanical systems
;Systems serving multiple ❑Not Applicable
;dwelling units must demonstrate
compliance with the IECC
:Commercial Provisions.
302.1 - Heating and cooling equipment is: Heating: Heating: ;❑Complies ;Requirement will be met.
403.7, ',. sized per ACCA Manual S based 1 Btu/hr Btu/hr Z❑Does Not
on loads calculated per
[PR2J„ P Coolin � Cooling:
Manual J or other methods ; g' ❑Not Observable ,
Btu/hr Btu/hr
approved by the code official. 1❑Not Applicable ;
I
Additional Comments/Assumptions:
11 High Impact(Tier 1) '2" Medium Impact(Tier 2) .11' Low Impact(Tier 3)
Project Title: LILIKAS RENOVATION Report date: 03/07/25
Data filename: Page 3 of10
,Section
Foundation`Inspection Fk , Compl�es�} `` Coitimenks/Assumptions
303=: 1 + _A protective covering is installed to I❑Complies ;Exception: Requirement is not applicable.
[F011]2 protect exposed exterior insulation E❑Does Not
.;' ; and extends a minimum of 6 in. below
grade. tlNot Observable
I❑Not Applicable
403. C Snow-and ice-melting system controls;❑Complies ;Exception: Requirement is not applicable.
[pF012]z installed. ;❑Does Not
i; ;❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
11 High Impact(Tier 1) 2`: Medium Impact(Tier 2) 3'= Low Impact(Tier 3)
Project Title: LILIKAS RENOVATION Report date: 03/07/25
Data filename: Page 4 of10
�Sectib s ,�f -�f did
amm I Rou h In Ins ectiort Plans Yer-11
if�ed F�elclVeir►fied� ;
�.:
9 9 P Values �Ualue Complies Comitients/Assumptions
&.R a .ID � �
402.1.1, ;Glazing U-factor(area-weighted U- ; U- ;❑Complies ;See the Envelope Assemblies
402.3.1, !average). E❑Does Not ;table for values.
402.3.3, I !
402.5 1 1❑Not Observable
[FR2]1 ! { ;❑Not Applicable
; ;
303.1.3 ;U-factors of fenestration products "'* °� ' r ''` ❑Complies ;Requirement will be met.
[FR4]1 !are determined in accordance ❑Does Not
!with the NFRC test procedure or
!taken from the default table. ❑Not Observable ,
a ;' ❑Not Applicable
402.4.1.1 ;Air barrier and thermal barrier ❑Complies ;Requirement will be met.
a
[FR23]1 I installed per manufacturer's fit, �' ❑Does Not
instructions. ❑Not Observable
! ❑Not Applicable
402.4.3 !Fenestration that is not site built ❑Complies :Requirement will be met.
[FR20]1 �is listed and labeled as meeting ❑Does Not
AAMA/WDMA/CSA 101/I.S.2/A440
or has infiltration rates per NFRC ❑Not Observable
400 that do not exceed code. ❑Not Applicable
limits. ;
�d2.4 5 = IC-rated recessed lighting fixtures ❑Complies :Requirement will be met.
sealed at housing/interior finish[FR16 ` � 4 '� �;C ,
], 9 ❑Does Not ;
and labeled to indicate<_2.0 cfm ❑Not Observable
leakage at 75 Pa.
❑Not Applicable ;
403.3.1 ;Supply and return ducts in attics ❑Complies ;Requirement will be met.
[FR12]1 !insulated >= R-8 where duct is []Does Not
I>= 3 inches in diameter and >= ,
,R-6 where < 3 inches. Supply and ❑Not Observable ;� `,��, �� � � ,
!return ducts in other portions of ; ❑Not Applicable ;
!the building insulated >= R-6 for
)diameter>= 3 inches and R-4.2 ';
!for< 3 inches in diameter. !
403.3.2 ;Ducts, air handlers and filter ❑Complies :Requirement will be met.
[FR13]1 !boxes are sealed with �u C Y�� ❑Does Not
ljoints/seams compliant with
;International Mechanical Code or []Not Observable ;
!International Residential Code, as ❑Not Applicable
!applicable.
Building cavities are not used as ❑Complies ;Requirement will be met.
[FR15]3 ducts or plenums. ❑Does Not
4MWEINot
[]Not Observable Applicable
403.4 ' `fie HVAC piping conveying fluids R- R- ;❑Complies ;Requirement will be met.
[F]117]z '"-above 105 QF or chilled fluids ! ;❑Does Not
I I
below 55 4F are insulated to >_R-
3 ; ;❑Not Observable
;❑Not Applicable
403.4.1 1 Protection of insulation on HVAC ❑Complies ;Requirement will be met.
❑
[FR24]1 1piping. HE' NEINot
Does Not ;
❑Not Observable
Applicable
403: :3 Hot water pipes are insulated to ; R- ; R- ;❑Complies !Requirement will be met.
[171118]2 >_R-3. ! i
1❑Does Not
. ;❑Not Observable
❑Not Applicable
4016 ��Automatic or gravity dampers are n ❑Complies ;Requirement will be met.
[FR19]z., )' installed on all outdoor air � ❑Does Not ;
_
W intakes and exhausts. ❑Not Observable
❑Not Applicable ;
11 High Impact(Tier 1) "2-1 Medium Impact(Tier 2) Y Low Impact(Tier 3)
Project Title: LILIKAS RENOVATION Report date: 03/07/25
Data filename: Page 5 of10
Additional Comments/Assumptions:
11 High Impact (Tier 1) J.,2`1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3)
Project Title: LILIKAS RENOVATION Report date: 03/07/25
Data filename: Page 6 of10
sectlonf sn.ti:r �r �'. a t a., a,l � �
Plans Verif�etl Field Verified
Insulation Inspection Compliesi Comments/Assumptions
Value Value
,� ,�.- a u
�' -,�;; •.d ,.ors_ a�S +
303.1 " ; All installed insulation is labeled ❑Complies ;Requirement will be met.
[013,]2 1•_• or the installed R-values ❑Does Not
I
provided.
.4°�� ❑Not Observable ;
❑Not Applicable
402.1.1, ;Floor insulation R-value. ; R- R- ;❑Complies ;See the Envelope Assemblies
402.2.E { ❑—Wood ❑ Wood :❑Does Not ;table for values.
[IN1]1 ❑ Steel ❑ Steel ;❑Not Observable
co
❑Not Applicable
I I I I i
I 1 1 I I
303.2, Floor insulation installed per 1 ❑Complies ;Requirement will be met.
402.2.8 !manufacturer's instructions and ❑Does Not ;
[IN2]1 in substantial contact with the
underside of the subfloor, or floor ❑Not Observable
Iframing cavity insulation is in ❑Not Applicable
Icontact with the top side of ;
!sheathing, or continuous
insulation is installed on they
underside of floor framing and
extends from the bottom to the
1top of all perimeter floor framing
I members.
402.1.1, 1 Wall insulation R-value. If this is a; R I R- I❑Complies ;See the Envelope Assemblies
402.2.5, !mass wall with at least 1/2 of the ❑ Wood ❑ Wood ;❑Does Not table for values.
402.2.6 {wall insulation on the wall {❑ Mass ❑ Mass {❑Not Observable
[IN3]1 lexterior,the exterior insulation I
requirement applies (FR10). ❑ Steel 1❑ Steel ;❑Not Applicable
1 I i 1 I
I 1 I 1
303.2 i Wall insulation is installed per f r rX 3 ' f ❑Complies ;Requirement will be met.
[IN4]1 !manufacturer's instructions. ❑Does Not
1
❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
11 High Impact(Tier 1) Z Medium Impact(Tier 2) 3. Low Impact(Tier 3)
Project Title: LILIKAS RENOVATION Report date: 03/07/25
Data filename: Page 7 of10
� � m; -
Plans Uerifietl Pield Verified �-;
# Final IiaspectonP,rov,�s�os Value` °f "' :Value ,F Complies' ; ,Comments/Assimptionsi
402.1.1, (Ceiling insulation R-value. ; R- ; R- ;❑Complies ;See the Envelope Assemblies
402.2.1, ;❑ Wood Wood ;❑Does Not :table for values.
402.2.2, I❑ Steel I❑ Steel !❑Not Observable
402.2.6
[Fill' I ; ;❑Not Applicable ;
1 I 1 I 1
i I I I 1
I I 1 I 1
303.1.1.1, ;Ceiling insulation installed per ! ❑Complies ;Requirement will be met.
303.2 !manufacturer's instructions. 4
° `�� ❑Does Not ,
[FI2]' ;Blown insulation marked every ;
1300 ft-. ❑Not Observable
❑Not Applicable ;
402.2.3 i Vented attics with air permeable ❑Complies ;Exception: Requirement is
[FI22]2 insulation include baffle adjacent ❑Does Not :not applicable.
to soffit and eave vents that I
' extends over insulation. ❑Not Observable ;
M�� M,
❑Not Applicable ;
402.2.4 ;Attic access hatch and door R- ; R- ;❑Complies ;Requirement will be met.
[FI3]' I insulation >_R-value of the ❑Does Not
;adjacent assembly. ; ❑Not Observable
❑Not Applicable
402.4.1.2 `Blower door test @ 50 Pa. <=5 ; ACH 50 = ; ACH 50 = ;❑Complies ;Requirement will be met.
[FI17]' ;ach in Climate Zones 1-2, and ElDoes Not
;<=3 ach in Climate Zones 3-8. ; ❑Not Observable
❑Not Applicable
403.3.3 !Ducts are pressure tested to cfm/100 ; cfm/100 ;❑Complies :Exception: Requirement is
[FI27]' I determine air leakage with ft2 ft2 ;❑Does Not :not applicable.
!either: Rough-in test:Total
;leakage measured with a :❑Not Observable
!pressure differential of 0.1 inch I ;❑Not Applicable ;
w.g. across the system including
,the manufacturer's air handler I
enclosure if installed at time of
;test. Postconstruction test:Total
(leakage measured with a 1
I 1 I !
!pressure differential of 0.1 inch
w.g. across the entire system
lincluding the manufacturer's air I
I handler enclosure.
I I ! I I
403.3.4 ;Duct tightness test result of<=4 ; cfm/100 ; cfm/100 ;❑Complies ;,Exception: Requirement is
[FI4]' (cfm/100 ft2 across the system stem or I ft2 ft2 ❑Does Not not applicable.
1
I<=3 cfm/100 ft2 without air
handler @ 25 Pa. For rough-in :❑Not Observable
!tests, verification may need to ;❑Not Applicable
;occur during Framing Inspection.
403.3.2.1 ;Air handler leakage designated '( + ' ❑Complies ;Requirement will be met.
[F[24]' !by manufacturer at<=2%of ❑Does Not
(design airflow.
I ❑Not Observable
❑Not Applicable ;
403.1 l,wl,a Programmable thermostats ❑Complies ;Exception: Requirement is
installed for control of primary ,� a, ° � ❑Does Not :not applicable.
heating and cooling systems and
initially set by manufacturer to ❑Not Observable
;. code specifications. ❑Not Applicable ;
4, 3,,; 2 i, Heat pump thermostat installed ❑Complies ;Exception: Requirement is
[FI10]2 ""on heat pumps. i ❑Does Not :not applicable.
❑Not Observable
❑Not Applicable
403:5a, - Circulating service hot water ❑Complies :Requirement will be met.
systems have automatic or ❑Does Not
accessible manual controls.
�- ❑Not Observable ;
. ❑Not Applicable ;
11 High Impact(Tier 1) r;2. Medium Impact(Tier 2) 11 Low Impact(Tier 3)
Project Title: LILIKAS RENOVATION Report date: 03/07/25
Data filename: Page 8 of10
Section,
Plans Verified "�Fie1d�Verifietl
` # .:FlihM Inspection Provisions Goinplies?' Comments/Assumptions'
Ualue Value
403.6 1 All mechanical ventilation system }.r._ ,` � ❑Complies ;Exception: Requirement is
[FI25P- ''fans not part of tested and listed " ��1
[]Does Not not applicable.
HVAC equipment meet efficacy I
and airflow limits per Table ❑Not Observable
R403.6.1. ❑Not Applicable
403'.2 Hot water boilers supplying heat ❑Complies ;Exception: Requirement is
[Ft26;12 'through one-or two-pipe heating ❑Does Not not applicable.
systems have outdoor setback
control to lower boiler water []Not Observable
temperature based on outdoor M ❑Not Applicable ;
temperature. _, „
403.5.1.1 Heated water circulation systems ` ❑Complies ;Exception: Requirement is
[FI28]2 have a circulation pump.The E, ❑Does Not :not applicable.
system return pipe is a dedicated
return pipe or a cold water supply ❑Not Observable
s` pipe.Gravity and thermos- `❑Not Applicable
i, syphon circulation systems are
not present. Controls for
circulating hot water system
r ,
pumps start the pump with signal
for hot water demand within the I
occupancy. Controls
automatically turn off the pump
when water is in circulation loop I
; is at set-point temperature and
no demand for hot water exists.
403.5.1.2 Electric heat trace systems a❑Complies :Exception: Requirement is
[17I29]2 comply with IEEE 515.1 or UL �° � ❑Does Not :not applicable.
515.Controls automatically p
adjust the energy input to the ❑Not Observable I
heat tracing to maintain the ❑Not Applicable
desired water temperature in the ;
;m Piping.
403-.5 2 i�` Demand recirculation water �' ` � ❑Complies ;Exception: Requirement is
�� 4f ���` :not applicable.
[FI30.]? systems have controls that � � I'I �+ ' ❑Does Not PP
manage operation of the pump r
and limit the temperature of the ❑Not Observable
water entering the cold water ❑Not Applicable
piping to <= 1001'.
403.5.4 Drain water heat recovery units ❑Complies ;Exception: Requirement is
[FI31]2 tested in accordance with CSA ❑Does Not :not applicable.
B55.1. Potable water-side
pressure loss of drain water heat �' " ❑Not Observable
$ recovery units < 3 psi for ❑Not Applicable
individual units connected to one
or two showers. Potable water-
side pressure loss of drain water
heat recovery units < 2 psi for
individual units connected to
three or more showers.
404.1 190%or more of permanentA_ ❑Complies :Requirement will be met.
[FI611 !fixtures have high efficacy lamps _ ❑Does Not
i [--]Not Observable
i � ❑Not Applicable
404.1 1 Fuel gas lighting systems have ❑Complies :,Exception: Requirement is
�[.FI23P, no continuous pilot light. � t -]Does Not not applicable.
U ❑Not Observable
- ❑Not Applicable
401.3 . �: Compliance certificate posted. �,,�� � � ° ° �"'� ��❑Complies ,Requirement will be met.
(FI7]2 ❑Does Not
,'r
❑Not Observable
Ah ❑Not Applicable
1 High Impact(Tier 1) 2: Medium Impact(Tier 2) 3:4. Low Impact(Tier 3)
Project Title: LILIKAS RENOVATION Report date: 03/07/25
Data filename: Page 9 of10
Section Plans Verified ' Field Verifiletl
# .xF�nal InspectionRrov�sions slue Value CompUes� �'Comments/Assumptions
& Recj l
303:3 Manufacturer manuals for ❑Com lies p !Requirement will be met.
[17118]3 � mechanical and water heating ❑Does Not
systems have been provided.
❑Not Observable ,
❑Not Applicable
Additional Comments/Assumptions:
11 High Impact (Tier 1) 2 Medium Impact(Tier 2) 13': Low Impact(Tier 3)
Project Title: LILIKAS RENOVATION Report date: 03/07/25
Data filename: Page 10 of10
2018 IECC Energy
Efficiency Certificate
Insulation Rating R-Value
Above-Grade Wall 15.00
Below-Grade Wall 0.00
Floor 30.00
Ceiling / Roof 49.00
Ductwork (unconditioned spaces):
D. .
Window 0.30 0.26
Door
Heating & Cooling Equipment Efficiency
Heating System:
Cooling System:
Water Heater:
Name: Date:
Comments
i
Q
ISSUES/REVISIONS
RESIDENTIAL GENERAL NOTES
MISC. GENERAL NOTES CLIMATIC AND GEOGRAPHIC CRITERIA FROM TABLE N 1 102. 1 .2 (R402. 1 .2) INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENT
1.THI5 PROJECT 15 THE CONSTRUCTION OF AN INTERIOR GARAGE RENOVATION FOR AN EXISTING ONE GROUND 5NOW LOAD 20 PSF (PER FIG. I C08.2 BCNYS 2020
STORY SINGLE FAMILY RESIDENCE,ZONED AS R-40. WIND SPEED(ULTIMATE DESIGN) 130 MPH (PER FIG. I C09.3(I)BCNY5 2020
2.THE EXISTING HEIGHT OF THE STRUCTURE AS DEFINED BY THE BUILDING CODE of NEW YORK STATE SEISMIC DESIGN CATAGORY B (PER SECT. I G 13 BCNYS 2020
2020 15 1 7'-0".THE PROPOSED ADDITION WILL NOT INCREASE THE HEIGHT. WINTER DESIGN TEMP I 1°F (PER TABLE N 1 101.2) ION SKYLIGHT GLAZED BASEMENT SLAB CRAWL
APPR VED AS NOTED
3.THE TYPE OF CONSTRUCTION 15 TYPE V(B). FLOOD ZONE N/A (PER FEMA MAP) CLIMATE F=NESTRAT CEILING WOOD FRAME MASS WALL FLOOR
4.ALL WORK SHALL CONFORM TO THE REQUIREMENTS OF THE 2020 BUILDING CODE of NEW YORK FROST LINE DEPTH 3G' FENESTRATIN WALL R-VALUE� SPACE WALL COMPLY WITH ALL CODES D ��e3�5 B,P l
WEATHERING PROBABILITY SEVERE (PERBCNY52020 ZONE U-FACTOR U-FACTOR R-VALUE WALL R-VALUE R-VALUE R-VALUE
STATE,2020 EXISTING BUILDING CODE of NEW YORK STATE,AND THE AF e PA WOOD FRAME DESIGN LOAD CALCULATIONS (UNIFORM LIVE LOADS) SHGC R-VALUE DEPTH R-VALUE NEW YORK STATE�TOWN CODES
CONSTRUCTION MANUAL BUILDING
5 HIGH WIND EDITION. S REOU�RED AND CONDATONS o, 1 e 0681�
5.DESIGN LOAD CALCULATION ARE BASED ON: PER TABLE 1 G07.1 BCNYS 2020 4 0.32 0.55 0.40 49 20 OR 13+5 8/ 13 19 10/ 13 I O, 2FT I 0/ 13 ► � �*.R
LIVE LOAD:AS PER TABLE R301.4,BUILDING CODE of NEW YORK STATE 2020. ROOMS OTHER THAN SLEEPING 40 P51
DEAD LOAD:CALCULATED AS PEP R301.3 AS PER BCNYS 2020. SLEEPING ROOMS 30 PSI "�� 1 F
ATTICS WITH LIMITED STORAGE 20 P51 4 ' '} 8 cI{ NOTIFY BUILDING DEPARTMENT AT
SNOW LOAD:20 P51 GROUND SNOW LOAD(AS PER FIG.R301.2(5)BCNY5 2020. ATTICS WITHOUT STORAGE 10 P51 � j�+�,~!,�+�M„��a LiJ �"i
WIND EXPOSURE CATEGORY"C",FOR 130 MPH 3 SECOND GUST. STAIRS 40 PSI Y� 8�1-765-1802 8AM TO 4PM FOR THE
,.,,,,,.,.,d li}e j�'�',"a rJSTEE FOLLOWING INSPECTIONS:
LOCATION LIVE DEAD DELECT LIMIT
'.YS.C00 FOUNDATION-TWO REQUIRED
I ST.FL. 40 LB. 12 U3G0
2ND.FL.(SLEEP AREA) 30 LB. 12 L/3G0 NAILING SCHEDULE v'c�ilti�;�-D��"�• OR POURED CONCRETE
51 ROUGH-FRAMING&PLUMBING
ATTIC(NON STORAGE) 20 LB. 10 U3G0 (PER AF t PA AMERICAN WOOD COUNCIL WFCM FOR
ROOF 20 LB. 15 U3G0 ONE AND TWO FAMILY DWELLINGS 2015 5BC HIGH WIND EDITION)
INSULATION
C.THE ARCHITECT ASSUMES NO RESPONSIBILITY FOR THE CONSTRUCTION MEANS,METHODS, JOINT DESCRIPTION NUMBER OF COMMON NAILS NAIL SPACING
TECHNIQUES,SEQUENCES,OR PROCEDURES,OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN ROOF FRAMING 13E C •COMPLETE
FOR
MUST
CONNECTION WITH THE WORK. RAFTER TO TOP PLATE(TOE-NAILED) 3 PER RAFTER 8E COMPLETE FOR C.O.
THERE ARE NO WARRANTIE5,NOR ANY MERCHANTIBIUTY OF FITNESS FOR A SPECIFIC USE EXPRESSED CEILING JOIST TO TOP PLATE(TOE-NAILED) 3 PER JOINT
OR IMPLIED IN THE USE OF THESE PLANS. CEILING JOIST TO PARALLEL RAFTER(FACE-NAILED) 3 EACH LAP LECTRIC/�L Alt CONSTRUCTION SHALL MEET THE
7.CONTRACTOR TO VERIFY ALL DIMENSIONS BEFORE STARTING CONSTRUCTION.DO NOT SCALE CEILING JOIST LAPS OVER PARTITION((FACE-NAILED) 3 EACH LAP INSPECTIOrd REQUIRED
OW DIMENSIONS ONLY. RIDGE STRAP(EACH END) 2 PER TIE
DRAWINGS.FOLLOW AE�UIREMENTS OF THE CODES OF NEW
TO SHALL FURNISH AND INSTALL ALL MATERIAL AND EQUIPMENT SHOWN,LISTED,OR BLOCKING TO RAFTER(TOE-NAILED) 2-8d EACH END YORK STATE. NOT RESPONSIBLE FOR
8.CNGS.
RIM BOARD TO RAFTER(END-NAILED) 2-16d EACH END DESIGN OR CONSTRUCTION ERRORS
DESCRIBED ON THESE DRAWINGS SUBJECT TO QUALIFICATIONS,CONDITIONS,OR EXCEPTIONS AS
WALL FRAM I NG
NOTED.CONTRACTOR SHALL FURNISH ALL LABOR,SCAFFOLDING,AND TOOLS NECESSARY TO
TOP PLATE TO TOP PLATE(FACE-NAILED) 2-1 Gd PER FOOT
COMPLETE THE WORK. TOP PLATES AT INTERSECTIONS(FACE-NAILED) 4-1 Gd J015T EA.51DE
9.ALL MATERIAL SHALL BE INSTALLED IN STRICT CONFORMANCE WITH MANUFACTURES REQUIREMENTS STUD TO STUD(FACE-NAILED) 2-1 Gd 24"O.C. PLUMSER CERTIFICATIOIN p
AND SPECIFICATIONS. HEADER TO HEADER(FACE-NAILED) I Gd I G"O.C.ALONG EDGES d V
10.CONTRACTOR SHALL OBTAIN ALL REQUIRED INSPECTIONS,APPROVALS AND CERTIFICATE OF TOP OR BOTTOM PLATE TO STUD(END-NAILED) 2-1 Gd,3-!Gd,4-1 Gd PER 2x4,2xG,2x8 RESPECTIVELY ON LEAD CONTENT BEFOREPIrOV I 5 mok,� Q Carbon
OCCUPANCY. BOTTOM PLATE TO FLOOR JOIST,BAND JOIST,
CERTIFICATE OF OCCUPANCY rnOnb l de &��RS as ►e u it d
END JOIST OR BLOCKING(FACE-NAILED) 2-16d PER FOOT
DEMOLITION
1. CONTRACTOR SHALL DEMOLISH EXISTING WALL5,FLOOR,ROOF AND EXISTING RAISED DECK AS FLOOR FRAMING
PCC INDICATED ON DRAWINGS AND AS NECESSARY,AND REMOVE ALL DEBRIS. J015T TO SILL,TOP PLATE TO GIRDER(TOE-NAILED) 4-8d PER JOIST 20�O e5id Cod o F IV
IN CONTRACTOR SHALL A ALL PATCHING REQUIRED DUE E REMOVAL OF EXISTING WORK AND OF BRIDGING TO JOIST(TOE-NAILED) 2-8d EACH END "'OLDER USED IN ".ATE R YS
INSTALLATION OF NEW WORK,AS NECESSARY. BLOCKING TO J015T(TOE-NAILED) 2-8d EACH END 'SUPPLY SYSTEM C�C!PIQT
3. ALL NEW WORK SHALL MATCH AND MEET FLUSH TO EXISTING WORK AS CLOSELY AS POSSIBLE UNLESS BLOCKING TO SILL OR TOP PLATE(FACE-NAILED) 3-I Gd EACH BLOCK 3 I`�� R 315 .
OTHERWISE NOTED. LEDGE STRIP TO BEAM(FACE-NAILED) 3-1 Gd EACH JOINT EXCEED 2/10 OF �% LE/ ,D.
4. EXISTING STRUCTURE AND INTERIORS TO REMAIN SHALL BE PROTECTED AS NECESSARY DURING JOIST ON LEDGE TO BEAM(TOE-NAILED) 3-8d PER JOIST
DEMOLITION AND CONSTRUCTION. BAND JOIST TO J015T(END-NAILED) 3-I Gd PER JOIST
5. CONTRACTOR SHALL PROTECT EXISTING SERVICES TO REMAIN AND SHALL NOTIFY ALL UTILITIES AND BAND JOINT TO SILL OR TOP PLATE(TOE-NAILED) 2-I Gd PER FOOT
TELEPHONE 5ERVICE5 AND MAKE ARRANGEMENTS FOR HOOK-UP,REMOVAL,OR CAPPING OF EQUIPMENT ROOF SHEATHING
AS NECESSARY. STRUCURAL PANELS 8d (TABLE ) ALL PLUMBING WASTE
DIAGONAL BOARD SHEATHING PLUMBING
FOUNDATIONS I NG,OR I"x8" 2-8d PER SUPPORT
1.A55UMED SOIL BEARING CAPACITY, 1,500 Ib./Sq.Ft. I'x 10"OR WIDER 3-8d PER SUPPORT
2.CONCRETE TO BE PLAIN,REINFORCED,3,000 Psi.-28 DAY TEST. &WATER LINES NEED
3.ALL NEW FOOTINGS TO REST ON UNDISTURBED SOIL. CEILING SHEATHING
GYPSUM WALLBOARD 5d coolers 7"EDGE/ 10'FIELD TESTING PE FORE COVERING
GENERAL CONSTRUCTION WALL SHEATHING
1.PROVIDE ALL LABOR,MATERIALS,TRANSPORTATION,EQUIPMENT AND SERVICES NECESSARY TO STRUCURAL PANEL 8d (TABLE 3.9)
COMPLETE ALL WOOD AND PLASTIC WORK REQUIRED BY THE DRAWINGS AS SPECIFIED HEREIN,OR FIBERBOARD PANELS
REASONABLY IMPLIED AS NECESSARY TO COMPLETE THE WORK.
2.FASCIAS,SOFFITS AND EXTERIOR TRIM SHALL MATCH EXISTING. 7/1 G" 8d 3"EDGE/G'FIELD
3.INTERIOR TRIM SHALL MATCH EXISTING. 25/32' 8d 3TDGE/G'FIELD
4.FRAMING ELEMENTS: GYPSUM WALLBOARD 5d coolers 7"EDGE/ 1 O"FIELD N 790 1 4'00" E Additional
A.ALL FRAMING LUMBER SHALL BE GRADE STAMPED DOUGLAS FIR-LARCH STRUCTURAL GRADE NO.2 HARDBOARD 8d (TABLE 3.9) d�l.><O
OR BETTER. PAPTICALBOAPD PANELS 8d (TABLE 3.9) 120.00'B.ALL ENGINEERED LUMBER SHALL BE AS INDICATED ON DRAWINGS,AND SHALL BE INSTALLED,CUT DIAGONAL BOARD SHEATHING - C`Y��+ ~y+�`t
AND DRILLED
IN SHEATH WG TO BE APA RATED.EXPOSURE ANCE WITH MANUFACTURERS REQUIREMENTSHINE S AS AND
NDICATEDCATIONS. 1"XCI OR I IX8" 2-8d PEP SUPPORT
I"x 10'OR WIDER 3-861 PER SUPPORT BeRea
L�u*� rC(�d
.
D.ALL SUB FLOORING TO BE APA RATED STUDD-I-FLOOR,EXPOSURE 1,3/4"MIN.THICKNE5. � r
E.ALL HEADERS 0-0"AND OVER SHALL BE SUPPORTED WITH DOUBLE UPRIGHTS,9'-0"AND OVER FLOOR SHEATHING
WITH TRIPLE UPRIGHTS.ALL HEADERS SHALL BE A MIN.OF(2)2"x8"OR AS SHOWN ON DRAWING. 5TRUCURAL PANELS
F.SOLID BLOCKING SHALL BE PROVIDED FOR ALL J015TS AND FLOOR BEAMS AS PER 5CNY5 2020 1"OR LE55 8d G"EDGE/ 12"FIELD
OR AS NOTED @ 8'-0"O.C.MIN..PROVIDE 2"SPACE FOR AIR CIRCULATION IN ROOF. GREATER THAN I' I Od G"EDGE/G'FIELD
G.PROVIDE DOUBLE FRAMING AROUND ALL OPENINGS(STAIRS,ETC.)OR AS NOTED ON DRAWINGS. DIAGONAL BOARD SHEATHING = _�
H.PROVIDE DOUBLE UP FRAMING UNDER ALL POSTS AND PARALLEL PARTITIONS OR AS NOTED ON 1"xG"OR I"x8" 2-8d PER SUPPORT
DRAWING. I"x 10"OR WIDER 3-8d PER SUPPORT -'
I.ALL FLUSH WOOD CONNECTIONS SHALL BE FASTENED WITH RATED GALVANIZED METAL PROPOSED SLAB
CONNECTORS BY'51MP50N"OR APPROVED EQUAL. I AND SPLIT-SYSTEM
J.NAILING SCHEDULE SHALL BE AS PER BUILDING CODE of NEW YORK STATE 2020 AS A MINIMUM. I 2 JANUARY,2025
ALL 2"xG"STUDS SHALL RECEIVE(5) 1 Od NAILS AT SILL AND PLATE.ALL EXTERIOR NAILS SHALL BE CON DENSER UNIT
GALVANIZED. SEE ATTACHED NAILING SCHEDULE. PROPOSED BASEMENT 15 JANUARY,2025
K.PLYWOOD SHEATHING TO BE NAILED 8d NAILS @ 4"O.C.EXTERIOR EDGES AND Gd NAILS @ 12.
O.C.INTERMEDIATE. SEE ATTACHED NAILING SCHEDUI F. // EGRESS WINDOW o3 JANUARY,2025
L.ALL INTERIOR AND EXTERIOR FINISHES TO BE SELECTED BY OWNER.
M.ALL ROOF RAFTERS SHALL BE ATTACHED TO THE PLATE AND STUD WITH GALVANIZED HURRICANE
TYPE CONNECTORS BY"SIMP50N"OR APPROVED EQUAL.FOR TIMBER PILE FOUNDATIONS,PROVIDE
HURRICANE CLIPS AT ALL PERIMETER JOISTS TO GIRDER CONNECTIONS. 24.3'
5.ALL NEW WINDOWS TO BE THERMAL INSULATED LOW-E GLASS,WITH ARGON GAS,IMPACT RESISTANT AS �' P 441-/^7"
REQUIRED. THESE PLANS ARE AN INSTRUMENT OF SERVICE
G.LOAD PATHS ARE INDICATED BY SECTION DRAWINGS. _
7.CONNECTIONS SHALL BE BUILT IN ACCORDANCE WITH ANSI/AF A PA WCFM-1995.(5EE NAILING +t AND ARE THE PROPERTY OF THE ARCHITECT.
INFRINGEMENTS WILL BE PROSECUTED
SCHEDULE) I I 1
8.FLASHING AT ALL WINDOW AND DOOR OPENINGS SHALL BE EPDM OR APPROVED RUBBERIZED
MEMBRANE. 2025 ALL RIGHTS RESERVED
9.FLASHING AT ROOF CONNECTIONS,VALLEYS,CHIMNEYS AND CRICKETS SHALL BE ALUMINUM.
10.STEP FLASHING SHALL BE USED AT ALL INTERSECTIONS OF SLOPED AND VERTICAL SURFACES,EXCEPT
STEP FLASHING AND COUNTER-AND CAP-FLASHING SHALL BE USED AT INTERSECTION OF ROOF AND /� N
CHIMNEY,AND ROOF AND WALL5. N
CATED ON THE DPAAING5 AND SHALL BE
z1 i/ZINSULATIONb. ENSITY FIBER-GLAS5IBATTS CONFORMING TO THE 5NSULATION OF THICKNESS I ECIFICATION5 FOP PRE OMED FIBROUS CORNER
GLA55 INSULATION.NAAMM STANDARD 51, I b-70. CLOSED-CELL SPRAY-IN FOAM INSULATION(R-G.5 PER { r.
INCH)BY ICYNENE OR APPROVED EQUAL SHALL BE PROVIDED A5 INDICATED ON DRAWINGS. I I O LD DO WN
!2.NEW INTERIOR DOORS SHALL MATCH EXISTING. Robert 1. Brown
I
13. NEW HARDWARE SHALL MATCH EXISTING.
14.GYPSUM BOARD SHALL BE EASED EDGE TYPE,CONFORMING TO A5TM C3G,AND SHALL BE 1
'5HEETROCK 5W BY U.S.GYPSUM CO.OR APPROVED EQUAL. GYPSUM WALLBOARD THICKNE55 SHALL BE I . I' Architect, P.C.
1/2"
15.ALL NEW AND REPAIRED GYP.BOARD SHALL BE TAPED AND SPACKLED THREE(3)COATS.ALL EXTERIOR \
5
CORNERS SHALL HAVE METAL CORNER BEADS. � / � I W Bay Ave. Greenport NY
Zo f
FINISHES /_/ _ �/ o _ I o _ inPo@ribrownarchitect.com
1. NEW WOOD FLOORS TO BE SELECTED BY OWNER,SANDED AND POLYUR_FTHANE,3 J IJ O _ _
COATS. / \ Icl o EXISTING I-STORY
2. EXISTING WOOD FLOORS SHALL BE SANDED AND REFINI5HED. � O O 631 477 975Z
�4, o 0o EXISTING IF STRUCTURE `n WOOD DECK �
3. CERAMIC TILE FLOOR SHALL BE SELECTED BY OWNER AND INSTALLED WITH THIN SET E 0 O
ADHESIVE. p _ COVERED
4.EXTERIOR FAINT SHALL BE LATEX ACRYLIC BY BENJAMIN MOORE OR APPROVED _ LOT 38 O O EQUAL,APPLIED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS AND z I PORCH (� E t V E
RECOMMENDATIONS. COLOR TO BE SELECTED. I nD ll��J nn
5.EXISTING INTERIOR WALLS AND CEILINGS IN ROOMS AFFECTED BY THE WORK SHALL Q _j ITBE CLEANED AND REPAINTED. NEW WALLS AND CEILINGS SHALL BE SEALED AND RIDGE CROSS SECTION END VIEW U IS A VIOLATION D THE LAW DIRECTION
PERSON,
PAINTED.PAINTING SHALL BE TWO (2)COATS BENJAMIN MOORE AQUA PEARL LATEX 1 1 UNLESS ACTING UNDER THE DIRECTION M A
ft � �I ZO25 LICENSED ARCHITECT,TO ALTER ANY ITEM ON
PAINTED,COLOR 7o A SELECTED.
THIS DRAWING IN ANY WAY. ANY AUTHORIZED
G. INTERIOR TRIM SHALL BE SANDED SMOOTH,PRIMED,AND FINISHED WITH TWO(2)
COATS BENJAMIN MOORE LATEX ACRYLIC 5EMI-GLO55 PAINT.
ALTERATION BE NOTED,
SEALED,
DESCRIBED N ACCORDANCE WITH THE LAW
HVAC
Ciullding D :
I.PROVIDE ALL LABOR MATERIALS,TRANSPORTATION,EQUIPMENT AND SERVICES
\� / utho^fit
;.A�S
NECESSARY TO PROVIDE A NEW SYSTEM TO HEAT AND COOL THE LIVING SPACES AS \ 4- / Trsvfn of SOutt�Oltl _
REQUIRED BY THE DRAWINGS AND SPECIFICATIONS AND THE 2020 MECHANICAL \
CODE of NEW YORK STATE,OR REASONABLY IMPLIED AS NECESSARY TO COMPLETE N PROPOSED
To WORK. °° 44'-7" / INTERIOR I'-I" `'y%' $ �� �
2.ABANDON AND REMOVE EXISTING OIL BOILER AND EXISTING OIL TANK. ° C>/� li R^:
3.ABANDON AND REMOVE ALL EXISTING RADIATORS AND NECESSARY PIPING. t I RENOVATION I +/ ���
4.INSTALL NEW SPLIT SYSTEM AND HEAT PUMPS IN LOCATIONS AS 5HOWN,U51NG EXISTING ASPHALT DRIVEWAY
�" �
MANUFACTURERS INSTALLATION GUIDES.
A/��
PLUMBING - T�
1.PROVIDE ALL LABOR,MATERIALS,TRANSPORTATION, EQUIPMENT,AND SERVICES
NECESSARY TO COMPLETE ALL NEW PLUMBING WORK REQUIRED BY THE DRAWINGS
AND SPECIFICATIONS AND THE 2020 PLUMBING CODE of NEW YORK STATE,OR
REASONABLY IMPLIED AS NECESSARY TO COMPLETE THE WORK.
2.CONFORM TO THE NEW YORK STATE ENVIRONMENTAL CONSERVATION LAW WITH
REGARDS TO WATER SAVING AND CONSERVATION. ALL FIXTURES SHALL BE ON THE
APPROVED"LIST OF CERTIFIED WATER SAVING PLUMBING FIXTURES"AS PUBLISHED BYE
THE NEW YORK STATE DEPARTMENT OF ENVIRONMENTAL CONSERVATION. 3'
3. ALL WORK ON THE PLUMBING SYSTEM SHALL BE PERFORMED BY OR UNDER THE -�
SUPERVISION OF A PROPERLY LICENSED MASTER PLUMBER. UPON COMPLETION,THE P
PLUMBER SHALL PROVIDE A SOLDER CERTIFICATE AS REQUIRED BY THE TO'NN OF - CLIENT OWNER
4.THE CONTRACTOR SHALL OBTAIN,SUBMIT,AND PAY FOR ALL PERMITS,
CERTIFICATIONS,LICENSES AND INSPECTIONS A REQUIRED BY LOCAL STATE,AND , LILIKAS
FEDERAL AUTHORITIES,AND ANY OTHER APPLICABLL E JURISDICTION.
5.ABANDON AND REMOVE EXISTING OIL-FIRED WATER HEATER.
G.PROVIDE NEW 50 GAL INSTANT ELECTRIC WATER HEATER.
Fl.00R ) MARINOS
ELECTRICAL J015T I
1.FURNISH ALL LABOR,MATERIALS,EQUIPMENT,PLANT,TOOLS,AND 5ERVICE5
NECESSARY AND REQUIRED FOR PROPER AND COMPLETE INSTALLATION OF ALL NEW - 505 CEDAR DRIVE
ELECTRICAL SYSTEMS AND RELATED WORK INCLUDING,BUT NOT LIMITED TO:CONNECT ��--��/�/ -
SERVICES,
O S TO PRDISOTRIBUTINSTALLED ELECTRICAL SYSTEMS,AND PROTECTION EQUIPMENT,CONNECTIONS NG,LIGHTING,
/ V' � - - EAST MARION, NY 11939
APPLIANCES, GROUNDING,AND ALL INCLUDING ALL CONNECTIONS AND DEVICES \ S 790 14'OO" W
WITHIN THE SCOPE OF THE WORK AS SHOWN ON THE APPLICABLE DRAWINGS AND "'
AND 5PCIFICATION5 AND AS NORMALLY SPECIFIED IN THIS TYPE OF PROJECT AND 120.00' PROJECT TITLE
INCLUDING CONNECTIONS TO PREVIOUSLY INSTALLED TRANSFORMERS AND
ELECTRICAL DISTRIBUTION SYSTEMS. 3 INTERIOR
2.ALL WORK SHALL CONFORM TO THE REQUIREMENTS OF THE 2020 BUILDING CODE �
of NEW YORK STATE,THE NATIONAL ELECTRICAL CODE,NFPA NO,70-2017(NEC), SITE PLAN BASED ON SURVEY BY:
LOCAL UTILITY STANDARDS,OCCUPATIONAL SAFETY AND HEALTH CAT(OSHA),THE ANDRE K. MILLER PLS
NATIONAL ELECTRICAL MANUFACTURERS'ASSOCIATION(NEVIN AND ANY OTHER i---
RENOVATIONS
APPLICABLE CODES. IN THE EVENT OF CONFLICT,THE MORE STRINGENT DATED: 5-29-2024
REQUIREMENTS WILL APPLY. = _- SCALE: I" = I O'-O"3.ALL PRODUCTS USED FOR ELECTRICAL WORK SHALL BEAR THE UNDERWRITERS FLOLABORATORIES,INC.LABEL AND BE SUITABLE FOR THE ENVIRONMENT IN WHICH THEY JO15 EXISTING EXCEPT AS NOTED SCTM: 1000-38.-4-27
WILL BE INSTALLED. -- DRAWING TITLE
4.ALL WORK ON THE ELECTRICAL 5Y5TEM SHALL BE PERFORMED BY OR UNDER THEZONED: R-40SUPERVISION OF A PROPERLY LICENSED MASTER ELECTRICIAN.5.THE CONTRACTOR 5HALL OBTAIN,SUBMIT,AND PAY FOR ALL PERMITS,LICENSESAREA: 12,000 SF (0.27 AC)
AND INSPECTIONS AS REQUIRED BY THE LOCAL,STATE,AND FEDERAL AUTHORITIES, SITE PLAN
AND ANY OTHER APPLICABLE JURISDICTION.
G.CARBON MONOXIDE DETECTORS IN CONFORMANCE WITH APPLICABLE CODES
5HALL BE CONNECTED TO THE LIGHTING CIRCUITS WITH NO INTERVENING WALL � ( GENERAL NOTES
SWITCH. LINE CORD-CONNECTED,DIRECT PLUG-IN,AND BATTERY POWERED ALARMS
ARE NOT ACCEPTABLE. ALARMS SHALL BE INSTALLED ON EACH LEVEL ON WHICH
SLEEPING QUARTERS ARE LOCATED. - -r
7.SMOKE DETECTORS IN CONFORMANCE WITH THE 2020 BUILDING CODE of NEW o e
YORK STATE,THE NFPA NATIONAL FIRE ALARM CODE NO.72-1993 SHALL BE - UPLIFT CONNECTIONS
SCALE
PROVIDED OUTSIDE EACH SEPARATE SLEEPING AREA,IN EACH 5PLEEPING AREA,AND
ON EACH FLOOR LEVEL. 07 MARCH,2025
1-0
CONTRACTOR SHALL COORDINATE WITH OWNER'S ALARM COMPANY FOR SMOKE AND
CONNECTIONS DETAIL 1/4"-
BURGLAR ALARMS AS NECESSARY.
DRAWING NO.
ISSUES/REVISIONS
REMOVE EXISTING DOOR
NEW CONCRETE BLOCK FOUNDATION
WALL TO MATCH EXISTING
TO BE FLUSH WITH TOP OF EXISTING
CONCRETE WALL
WATERPROOFING SEALER BELOW GRADE
NEW P.T. SILL PLATE w/FLASHING
EXISTING WINDOW EXISTING WINDOW NEW ANCHOR BOLTS @ 24"O.C. w/
TO REMAIN TO REMAIN MINIMUM (1)WITHIN 12"OF CORNER
REMOVE EXISTING WINDOW WASHER RYYER REMOVE EXISTING
GUT EXISTING CONCRETE WALLLO- � OIL HEATING
NEW BASEMENT SYSTEM AND ALL
NEW 54" BILCO 5CAPEWEL EGRESS WINDOW d RADIATOR PIPING
EGRESS WINDOW 48G2-54 ANDER5EN 400 SERIES
w/DOME COVER CXW 145 CASEMENT EXISTING BATHPI OM
WINDOW TO REMAIN
INSTALLED USING
MANUFACTURERS GUIDE WINDOW SILL HEIGHT O - EXISTING
TO BE LESS THAN 44" MECHANICAL ROOM
SEE DETAIL ON DWG A2 ABOVE FLOOR
Ll
in
in NOTCH EXISTING CONCRETE
EXISTING BEDROOM#4 WALL AS NECESSARY FOR
EXISTING COLUMNS DROP BEAM
TO REMAIN_ _—- - _ - T�— - - _ _�—- - -—� I - _ - _ - NEW(2) 2x8 DROP BEAM
EXISTING DROP BEAM TO MAIN
i
INEW(3) 2x8 FLUSH BEAM
FLUSH w/EXISTING FLOOR JOISTS
CUT OUT EXISTING FLOOR JOISTS
IREPAIR AND PATCH AS NECESSARY I
BRACE EXISTING FLOOR w/TEMPORARY COVER EXISTING
i SUPPORTS AS NECESSARY i CONCRETE STAIR
EXISTING WINDOW EXISTING FINISHED BASEMENT
TO REMAIN 3G" HANDRAIL
� NEW 2x4 STUD WALL �
TO CODE(TYP.) NEW
NEW STAIR: 3OG8
EXISTING RISE: 7 Y"
ELECTRIC PANEL RUN: 9Y2' (UP
RISERS: 12
-JF-r L
EXISTING WINDOW
TO REMAIN REMOVE EXISTING 2x4 WALL STUDS
NEW CONCRETE BLOCK FOUNDATION
WALL TO MATCH EXISTING
TO BE FLUSH WITH TOP OF EXISTING
CONCRETE WALL
WATERPROOFING SEALER BELOW GRADE
NEW P.T. SILL PLATE w/FLASHING
NEW ANCHOR BOLTS @ 24"O.C. w/
MINIMUM (1)WITHIN 12"OF CORNER BASEM ENT PLAN 28 JANUARY,2025
SCALE: 1/4" = I'-0" 15 JANUARY,2025
EXISTING EXCEPT AS NOTED o3 JANUARY,2025
THESE PLANS ARE AN INSTRUMENT OF SERVICE
AND ARE THE PROPERTY OF THE ARCHITECT.
INFRINGEMENTS WILL BE PROSECUTED
2025 ALL RIGHTS RESERVED
8
EXISTING DECK TO REMAIN T
Robert I. Brown
Architect, P.C.
REMOVE EXISTING DOOR NEW SIDING TO MATCH 205 Bay Ave. Greenport NY
NEW 2x4 FRAMED WALL AND OPENINGS EXISTING info@rlbrownarchitect.com
NEW ANDERSEN 400 SERIES REPAIR AND PATCH AS 631-477-9752
(3)TW 21052 DOUBLE HUNG WINDOWS NECESSARY
WHITE/WHITE
EXISTING WINDOW EXISTING WINDOWS EXISTING DOOR NEW WINDOW TRIM TO MATCH EXISTING
TO REMAIN TO REMAIN TO REMAIN 3'-I" 3--IN k 4'-1 1/2"
IT IS A VIOLATION OF THE LAW FOR ANY PERSON,
UNLESS ACTING UNDER THE DIRECTION OF A
REMOVE EXISTING BASEBOARD \ REMOVE EX15TING BASEBOARD I I 3'-9" LICENSED ARCHITECT,TO ALTER ANY ITEM ON
RADIATOR AND ALL NECESSARY PIPING RADIATOR AND ALL NECESSARY PIPING I I 3" 3" THIS DRAWING IN ANY WAY. ANY AUTHORIZED
ALTERATION MUST BE NOTED,SEALED,AND
DESCRIBED IN ACCORDANCE WITH THE LAW.
I J o
m < NEW R-15 BATT INSULATION ,� ."� p '�'
EXISTING WINDOW m U IN EXISTING 2x4 WALL CAVITIES `v; s
Q w REMOVE EXISTING WALL I �.E sS;4e
EXISTING BEDROOM#I w PROVIDE TEMPORARY SUPPORT • ,•;`:
TO REMAIN I I
z z EXISTING KITCHEN AND BRACING AS NECESSARY PROPOSED LIVING ROOM .. .� t
TO REMAIN I I
Q TO REMAIN EXISTING GARAGE SLAB TO REMAIN <;tI
x o I I NEW 2x8 FLOOR JOISTS ,
t w Z I I " A^�..w� * k d
PLYWOOD
> I I NEW FLOORINGTO E SELECTED
l W4
00 I I TO BE LEVEL WITH EXISTING FLOOR
iuQ II ---
� II
EXISTING (2) 2x 10 DROP BEAM TO REMAIN I I NEW 4x4 SQUARE COLUMN REMOVE EXISTING WINDOW
�� SQUARE PANEL CLADDING FRAME STUD WALL AS NECESSARY CLIENT/OWNER
EXISTING COLUMN
TO REMAIN I I REMOVE ALL EXISTING DRYWALL ON LI LI
WALLS AND CEILING IN NEW AREA I`ll 1�
NEW R-1 5 BATT INSULATION IN EXISTING
z I I 2x4 WALL CAVITIES
� NEW 7.5"CLOSED CELL 5PRAY-IN FOAM MARINOS
Q > CUT NEW OPENING FOR BASEMENT STAIR INSULATION (R-49) IN EXISTING
m Q 42" KNEE WALL w/FINISHED WOOD CAP I I 2x8 ROOF RAFTER CAVITIES 505 CEDAR DRIVE
N N 3G"HANDRAIL TO CODE(fYP.) NEW R 30 BATT INSULATION IN NEW 2x8
m w 4'-7 1/2" 10'-0 I/2" 4'-5" I FLOOR JOISTS EAST MARION, NY 11939
EXISTING WINDOW I NEW R-1 5 BATT INSULATION
z _j EXISTING BEDROOM#2 EXISTING BEDROOM#3 3G" HANDRAIL I I REMOVE EXISTING WAIL IN EXISTING 2x4 WALL CAVITIES
TO REMAIN Q TO REMAIN TO REMAIN TO CODE(TYP.) I I PROVIDE TEMPORARY SUPPORT PROJECT TITLE
Ln AND BRACING AS NECESSARY
A w Q ° N NEW STAIR:
I I A INTERIOR
A3 O M VE EXI TI G B A RUN: 9Yz" I I A3
w Q DI TO A D LL NE ES A Y PI RISERS: 1 2 I I NEW(2) 2x I O HEADER 31, RENOVATIONS
o REMOVE EXISTING BASEBOARD I I 3" 3"
RADIATOR AND ALL NECESSARY PIPING J,i,(' J,!("
EXISTING WINDOWS
TO REMAIN DRAWING TITLE
EXISTING WINDOW EXISTING WINDOW 8'-I I" 3'-3" 3'-3" 3'-1 1 1/2"
TO REMAIN TO REMAIN 11
EXISTING PORCH TO REMAIN REMOVE EXISTING WALL AS NECESSARY NEW SIDING TO MATCH FLOOR PLAN
NEW 2x4 FRAMED WALL AND OPENINGS EXISTING BASEMENT PLAN
NEW ANDERSEN 400 SERIES REPAIR AND PATCH AS
(3)TW 21052 DOUBLE HUNG WINDOWS NECESSARY
WHITE/WHITE
NEW WINDOW TRIM TO MATCH EXISTING
SCALE
FLOOD PLAN 07 MARCH,2025 1/4"=i-o"
DRAWING NO.
SCALE: 1/4" = 1'-0"
EXISTING EXCEPT AS NOTED B
SCTM: 1000-22-2-38 A3
ZONED: R-40
i
ISSUES/REVISIONS
EXISTING ROOF TO REMAIN
(2) 2xG P.T. BOX
GRADE SLOPED AWAY
NEW BASEMENT EGRESS WINDOW
NEW 54" BILCO SCAPEWEL
—` A ❑ I NEW WINDOW TRIM NEW 51DING TO MATCH ANDERSEN 400 SERIES CXW 145
II I CASEMENT WINDOW
EGRESS WINDOW 4862 54
TO MATCH EXISTING EXISTING
I�—J ❑ - � w/DOME O
REPAIR AND PATCH AS INSTALLED USING
— NECESSARY WINDOW SILL HEIGHT I
MANUFACTURERS GUIDE
TO BE LESS THAN 44
❑ ABOVE FLOOR N
-1 Ell I- -um
— — — — — — — — — — — — — — REMOVE EX15TING SIDING
AS NECESSARY
NEW 51DING TO BE LEVEL
WITH EXISTING REMOVE EX15TING 2x4 WALL STUDS S E CT I O' `��I DETAIL
NEW CONCRETE BLOCK FOUNDATION
WALL TO MATCH EXISTING SCALE: 1/4' = 1'-0"
28 JANUARY,2025
EX15TING EXCEPT AS NOTED
WEST ELEVATION (FRONT) 15 JANUARY,zoz5
SCALE: 1/4" = 1'-0" o3 JANUARY,2025
EXISTING EXCEPT AS NOTED
THESE PLANS ARE AN INSTRUMENT OF SERVICE
AND ARE THE PROPERTY OF THE ARCHITECT.
INFRINGEMENTS WILL BE PROSECUTED
zoz4 ALL RIGHTS RESERVED
Robert I. Brown
Architect, P.C.
ao Bay Ave. Greenport NY
EXISTING ROOFING TO REMAIN in?o@ribrownarchitect.com
EXISTING RAFTERS TO REMAIN 631 477-9752
NEW 7.5"CLOSED CELL SPRAY-IN FOAM
INSULATION(R-49) IN EXISTING
2x8 ROOF RAFTER CAVITIES
i;�',° '_: :' 'r""'t;_ h^.'ry v',' ''. ✓ '.Y_=:v EXISTING ROOFING TO REMAIN IT IS A VIOLATION OF THE LAW FOR ANY PERSON,
i � xp
EXISTING RAFTERS TO REMAIN "'" UNLESS ACTING UNDER THE DIRECTION OF A
EXISTING ROOF TO REMAIN ,.'4;. LICENSED ARCHITECT,TO ALTER ANY ITEM ON
NEW 7.5 CLOSED CELL SPRAY-IN FOAM ��:'��� ;,��,
CATHEDRAL CEILING INSULATION(R-49) IN EXISTING _ .. THIS DRAWING IN ANY WAY. ANY AUTHORIZED
NEW 2x4 STUD WALL EQ E4 I xG NICKLE GAP WOOD PLANK �s zr th ALTERATION MUST BE NOTED,SEALED,AND
2x8 ROOF RAFTER CAVITIES -,ir`'`. CATHEDRAL CEILING
----- -- - -- --- PAINTED WHITE ,�uP I xG NICKLE GAP WOOD PLANKS ``'��., DESCRIBED IN ACCORDANCE WITH THE LAW.
Sid..
r=.. '_
2x 10 COLLAR TIES @ 48"O.C. PAINTED WHITE„�,.-
EXISTING CEILING TO REMAIN 515TER EXISTING J015T I BOXED w/ I x 10 WOOD PLANKS
NEW 2x8 FLUSH BEAM PAINTED WHITE
2x 10 COLLAR TIES @ 48"O.C. �,�,x •r .�, ..BOXED w/ I x 10 WOOD PLANKS ` 4 ta, .` ';• a
AINT
REMOVE EXISTING WALL
EXISTING(2) 2x 10 DROP BEAM PROVIDE TEMPORARY SUPPORT AND NEW(2) 2x I 0 HEADER(TYP.) NEW(2) 2x 10 HEADER
TO REMAIN BRACING AS NECESSARY
NEW 4x4 SQUARE COLUMN
5QUARE PANEL CLADDING �, I
EXISTING WALL TO REMAIN NEW R-1 5 B M
ATT INSULATION IN EXISTING �0
PROPOSED LIVING ROOM REPAIR AND PATCH A5 NECESSARY 2x4 WALL CAVITIESLn
NEW 2x8 FLOOR JOISTS NEW SIDING TO MATCH EXISTING
NEW 3/4" PLYWOOD SUBPLOOR REPAIR AND PATCH AS NECESSARY
EXISTING BEDROOM#2 EXISTING BEDROOM#3 R-30 BATT INSULATIONNEW FLOORING TO BE SELECTED
TO REMAIN TO REMAIN CLIENT OWNER
TO BE LEVEL WITH EXISTING FLOOR � NEW 2x8 FLOOR JOISTS @ I G"O.C.
-..; - ANCHOR NEW FLOOP,J015T REMOVE EXISTING 2x4 WALL 5TUD5 NEW R 30 BAIT INSULATION
> .; ?;;^v ?,^ :x ,, c=�: NEW CONCRETE BLOCK FOUNDATION
NEW(3) 2x8 DROP SLAM TO STUD WALL WALLT MA .; rrr' : ,,.. :. :,?, } . 'f; sak s:_c .sa-.r• n .t,.; o,.wv :,x; , ,.r.T ;.. LILIKAS
EXISTING FLOOR JOISTS TO MAIN J O MATCH EXISTING
/ TO BE FLUSH WITH TOP OF EXISTING NEW(3) 2x8 DROP BEAM MARINOS
(3) 2x8 FLUSH BEAM CONCRETE WALL
CUT OUT EXISTING FLOOR JOISTS N EXISTING SLAB TO REMAIN NOTCH EXISTING CONCRETE WATERPROOFING SEALER BELOW GRADE GRADE
p REPAIR AND PATCH AS NECESSARY p CLEAN AND DRY WALL AS NECESSARY FOR NEW P.T. SILL PLATE w/FLASHING EXISTING SLAB TO REMAIN 505 CEDAR DRIVE
BRACE EXISTING FLOOR w/TEMPORARY DROP BEAM NEW ANCHOR BOLTS @ 24"O.C. w/ CLEAN AND DRY
SUPPORTS AS NECESSARY NEW BASEMENT STAIR: MINIMUM (1)WITHIN 1 2'OF CORNER EAST MARION, NY 11939
RISE: 7 "
RUN: 9'/2" EXISTING FOUNDATION PROJECT TITLE
RISERS: 12 WALLS TO REMAIN EXISTING FOUNDATION
SECTION D TO REMAIN I NTE RI O R
EXISTING FOUNDATION SCALE: 1/4" = 1'-0" RENOVATIONS
WALLS TO REMAIN EXISTING FOUNDATION EXISTING EXCEPT AS NOTED
WALLS TO REMAIN
SECTION � ABANDON EXISTING STAIR
DRAWING TITLE
SCALE: 1/4" = I'-O"
ELEVATIONS
EXISTING EXCEPT AS NOTED
SECTIONS
SCALE
o7 MARCH,2025 1/4"=i-o"
I DRAWING NO.
I
ISSUES/REVISIONS
v® � qp 9 REMOVE EXISTING OIL
NEW SPLIT SYSTEM HEATING SYSTEM AND ALL
ZONE (3) RADIATOR PIPING
->< WASHER DRYER REMOVE EXISTING OIL TANK
REMOVE EXISTING OIL-FIRED
WATER HEATER
EXISTING LIGHT NG
EXISTING LIGHTING TO REMAIN NEW 50 GAL INSTANT
ELECTRIC WATER HEATER
TO REMAIN O
SD CO
m m
EXISTING LIGHTING
TO REMAIN
I
d
UPGRADE EXISTING _ I TO PSTAIRS
ELECTRIC PANEL � S ETCH ELECTRICAL LEGEND
NEW SPLIT SYSTEM SD COO 3
O �
i ZONE (3)
® LIGHT SWITCH
3 = THFEE WAY
D = DIMMER
® JAM SWITCH
OUTLET
GFI= GROUND FAULT INTEKUPT
220 = 220 VOLT
4 = QUAD OUTLET
FIXTURE :
S= SURFACE MOUNT PROVIDED BY OWNER
R= RECESSED PROVIDED BY CONTRACTOR
FO WALL SCONCE HOSE
BASEMENT ELECTRICAL PLAN < PHONE BIBS
SCALE: 1/4" = P-0" O— CABLE 5E NETWORK CABLE
EXISTING EXCEPT AS NOTED Q SPEAKERS
4 ALARM KEYPAD 28 JANUARY,2025
4 THERMOSTAT 15 JANUARY,2025
® VENT
THESE PLANS ARE AN INSTRUMENT OF SERVICE
AND ARE THE PROPERTY OF THE ARCHITECT.
SD CO CARBON MONOXIDE DETECTOR INFRINGEMENTS WILL BE PROSECUTED
EPH ELEC. PANEL HEATER
2025 ALL RIGHTS RESERVED
PHONE/COMM.
LIGHT TRACK
PC PULL CHAIN Robert I. Brown
FL PORTRAIT LIGHT 5'G"TO CLOCK OUTLET Architect, P.C.
,r DIRECT LIGHTING 20 Bay Ave. Greenport NY
REMOVE EXISTING --�
in o ribrownarchitect.com
�.j BASEBOARD RADIATOR AND I G' FLUORESCENT 631-477-9752
`r ALL NECESSARY PIPING
SPOTLIGHT
REMOVE EXISTING BASEBOARD ®$ i
RADIATOR AND ALL NECESSARY PIPING NEW SPLIT SYSTEM IT IS A VIOLATION OF THE LAW FOR ANY PERSON,
ZONE(2) UNLESS ACTING UNDER THE DIRECTION OF A
LICENSED ARCHITECT,TO ALTER ANY ITEM ON
HANGING LIGHT THIS DRAWING IN ANY WAY. ANY AUTHORIZED
0
O z /�' `(� FIXTURES ALTERATDESCRIBED INAC ACCORDANCE WITH ON MUST BE NOTED, LTHE�
� az / \
z
z 0 !�: / 1
x 0 MEXISTING LIGHTING
,u QQ u0 TO REMAINLu
LU
NEW SPLIT SYSTEM ,L, 0 z
ZONE(1) °L Cu J 6 HANGING LIGHT
Q Q FIXTURES �•
CD
rj n r
L—00
EXISTING LIGHTING
TO REMAIN
CLIENT/OWNER
SD CO ` �`r' Y\ FIXTURES LIGHT
o NEW SPLIT SYSTEM Lj I / \ L I L I K-A-S
Q O ZONE(1) Sp SD CO f \
z o L c0 T, MARINOS
O
X Q - + �\ 505 CEDAR DRIVE
w HANGING LIGHT
w0ui z EAST MARION, NY 11939
> CZ
Q FIXTURES
I ( _ \ z ( i
Lu w \ PROJECT TITLE
Q Q NEW SPLIT SYSTEM TO DOWNSTAIRS / NEW SPLIT SY4EM
m ZONE(I) SWITCH �� ZONE(2)
ER 3
INTERIOR
REMOVE EXISTING BASEBOARD I RENOVATIONS
REMOVE EXISTING RADIATOR AND ALL NECESSARY PIPING
BASEBOARD RADIATOR AND
ALL NECESSARY PIPING
DRAWING TITLE
ELECTRICAL PLAN
FI RST FLOOD ELECTRI CAL PLAN
SCALE
SCALE: 1/4" = 1'-0" 07 MARCH,zoa5 1/4,=i-o'
EXISTING EXCEPT AS NOTED
DRAWING NO.