Loading...
HomeMy WebLinkAbout51837-Z �o'�pf SOUryO`° Town of Southold * * P.O. Box 1179 � roc 53095 Main Rd Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 46323 Date: 07/17/2025 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 280 The Short Ln East Marion, NY 11939 Sec/Block/Lot: 30.-2-9 Conforms substantially to the Application for Building Permit heretofore,filed in this office dated: 03/10/2025 Pursuant to which Building Permit No. 51837 and dated: 04/17/2025 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: Roof-mounted solar panels to existing single-family dwelling as applied for. The certificate is issued to: Steven Stathoudakis ,Antonia Stathoudakis Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: 51837 5/22/2025 PLUMBERS CERTIFICATION: Au o ' Signature �,toFso&, TOWN OF SOUTHOLD BUILDING DEPARTMENT • TOWN CLERK'S OFFICE Comm SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 51837 Date: 04/17/2025 Permission is hereby granted to: Steven Stathoudakis 235 80th St Brooklyn, NY 11209 To: install roof-mounted solar panels to existing single-family dwelling as applied for. Premises Located at: 280 The Short Lnjast Marion, NY 11939 SCTM#30.-2-9 Pursuant to application dated 03/10/2025 and approved by the Building Inspector. To expire on 04/17/2027. Contractors: Required Inspections: Fees: SOLAR PANELS $100.00 ELECTRIC Residential $125.00 CO-RESIDENTIAL $100.00 Total $325.00 Building Inspector o��pE SO!/��,ol � o Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 G • Q Southold,NY 11971-0959 �y�OUNTY,�� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Steve Stathoudakis Address: 280 The Short Ln City: East Marion St: NY Zip: 11939 Building Permit#: 51837 Section: 30 Block: 2 Lot: 9 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: Element Energy License No: 52689ME SITE DETAILS Office Use Only Indoor Basement I— Service r Solar F Outdoor F 1st Floor Pool F Spa r Renovation r7 2nd Floor I— Hot Tub r Generator r Survey r Attic r Garage Battery Storage r INVENTORY Service 1 ph (— Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph 17 Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures Other Equipment: 14.875kW Roof Mounted PV Solar Energy System w/ (35)JKM425N-54HL4-B Mod., IQ5 Combiner w/.(3)220 & (1)115 Breaker, 60A Fused AC Disconnect, Lineside Tapped Notes: Solar Inspector Signature: X Date: May 22, 2025 Sean Devlin Electrical Inspector sean.devlin(D-town.southold.ny.us 280TheShortSolar OF 50UTyo� t ES 7 2, `r 7 �,Q # TOWN OF SOUTHOLD BUILDING DEP . cn 631-765-1802 INSPECTI.ON [ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [. ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE& CHIMNEY [ 'I FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ]. RENTAL REMARKS: L,Ale L 0 V A 41n-�4 2.rCALC ii rcy9tff d 9.A / r IV t.+-v cl c DATE INSPECTOR tE�;n J OF SOUlyolo * # TOWN OF SOUTH'OLD -BUILDING DEPT. `ylou m, 631-765-1802 INSPECTION [ ] FOUNDATION 1 ST_/ REBAR [ ] ROUGH PLBG. [ ]- FOUNDATION 2ND [ ] I SULATION/CAULKING [ ' ] FRAMING /STRAPPING [ FINAL .0 1ke—, [ } FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION'_ [ ] FIRE RESISTANT PENETRATION [ .] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE-VIOLATION [ ] PRE C/O [ ] RENTAL- REMARKS: DATE /7aS INSPECTOR Q ' °a google:.:com/sear( ) Q These are results for why does my main panel pc 230 not have nuts holding the housing together Search instead for why does my main panel pc 230 not have nuts-holding the housing yogether All Overview )+4:,14 Your observation that your main panel PC 230 housing doesn't use nuts for .assembly suggests it likely employs alternative fastening methods. Common ways housings'are held together with • Snap-fit connectors: These are integrated features on the housing parts that interlock to secure the enclosure. • ousing might be held together by-screws that thread directly into the plastic or into threaded inserts within the plastic. • Ultrasonic welding: This process uses ultrasonic vibrations to create heat and melt the plastic, fusing the parts together at a molecular level. 2:06 ® 5e,(9 0 ,all Q °o goog,le corn/sear( Q J Google C� what is a dnap fit connect X y All Images Videos Shopping 'Short video: Including results for what is a snap fit connector Search only for what is a dnap fit connector + Al Overview k, +12 A "snap-fit connector" is a type of ¢connector,that uses a.snap=in I echanism- to create a secure and; quick connection,,, often without the need for screws or other fastene6-s. These connectors are frequently used in various applications, including assembly of plastic parts, modular structures, and in electrical and pneumatic connections. Here's a more .detailed breakdown: Kev Characteristics of Snap-Fit III 0u do, a �o o DR �1 1— 4 meat - �Utt3tn�o sovtrold a s .to% 10 11 12 13 14 15 16 17 18 19 20 A�WARNING !---)UAL POWER SUPPLY i SOURCES: UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM ' � LC230EC IcaMxwnnoN Ell LC230PC�coreov,,,non coven�o.Mre.wme uxery ��� __. � :�.. LC230PCC¢ormvuTwn wven zeo w,P nwu,eaexen� -_.�. °I•• ,f r, _ r� I L -yyw sou • 1T ~ EQfRAPI -- a w - axewu[t��[e UESRVio EEOUPMNNT ,ca..sumx_rmm+�rn,xx�-au .m nx vcc.i�vn'ximEsr w Ne pu�•e to umcsara� y E�I���}v wucwss�cri�onm���pus�me nmcnrn.-crww.nremo-rt rr of wEwrnecn.¢.as =aoo k.e� !rs�m� .. +eKuar0.r',xm �a•••�•� .. �I IIFS- mdro. ,AN R PV USE CUIU/A.L W�IPmsnvc+rnrsa Z suui,eian+,�'a+�:`ne ucac ,xfE,.,m,umocem�uxraawn Fy, n � ' "'�n'^< im+`nr+mra.wiaasa¢mc'r�°'"�9r�^•"" - vn�uM avxn epn .� s,.mf..y+ v a°•° � �p a M._1-114 � 1:33 Y = 5 • 0 r6 , < 6 Sean Southold I... v OK DATE %>INSPECTOR r MMS 12:42 PM I have not 12:46 PM Ok let me know what we should • • next. The electrician says the panel clips are what • • that panel • • it comes 12:51 PM III 0 < f f 'S W 1 R y V S y. Ad aX" 4• � a ow ' I f i 1 i i a rt. x ' t Yi �. M ly 1 �r 1 4 i, 1 w � v Page 1 of 1 ig 40 U Southold town Current a 2025 Renewables05/19/2025 ��� Engineering JDUJ1d`„5®S t o id Subject: Structural Observation4WA Job: Stathoudakis, Steve - 280 The Short Lane Project Address: 280 The Short Lane, East Marion, NY, 11939 Attn.: To Whom It May Concern After inspecting the installation of the above referenced project, it is the opinion of Current Renewables Engineering to certify that to the best of our knowledge, belief, and professional judgment the PV installation is in conformance with the Structural Calculations. Verification of all relevant installation methods and materials was provided by Element Energy LLC. This letter does not waive the installer of any responsibility for improper installation. If you have any further questions on the above, please do not hesitate to reach out. ,tat NEwy Current Renewables Engineering Inc. *�pPSH ZAo�* Professional Engineer info@currentrenewableseng.com tiSFO 101084 '°R FE �pNP Exp.01/31/2028 Signed on:05/19/2025 3600 Lime St Bldg 2,Ste#224,Riverside,CA 92507 (951)203-5933 info@currentrenewableseng.com - -FIELD INSPECTION REPORT DATE-7 COMMENTS ............ FOUNDATION (IST) 7 ... -------------------------------------- ----------- .......... FOUNDATION (2ND) ------ O ----------- zl_ 0 ROUGH FRAMING & ........... PLUMBING -------- INSULATION PER N. Y. STATE ENERGY CODE ........... i as 64 0- FINAL fi ADDITIONAL COMMENTS 5;70-�R- A* loqg& 0 ............... ........... ....... 0 .......... ......------- .... .......... �� LL TOWN OF SOUTH OLD D —BUILDING DEPARTMENT ENT C. yyyyyy' Town Full Annex 54375 Main Road P. 0. Box 1179 Southold, NY 11971-0959 N 2� oyo Telephone (631) 765-1802 Fax (631) 765-9502 https /,'www.southoldtownny.eov Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only f PERMIT NO._5JS2 J Building Inspector: MAR 1 0 2025 Applications and forms must be filled out in their entirety.fncomplefe applications will not be accepted. Where the Applicant is not the owner,an Suifofing Department Owner's Authorization forme(Page Z)shall be completed. Tovm of Southold Date: OWNER(S).OF PROPERTY: Name: . w41 U 4- -1�-�I SCTM# 1000- 036 . —0 Z. OV —O U q.ono Project Address: OZ $u 7Ku-._S ffiP.` 0n t�. I Phone#: Co3 6_ 38 2 , -7®q I Email: r-..r l 1� Mailing Address: cP-g l7 TKC, J 110Y4 1 ,, -t EA44 m L.�/ UY1 �y.- It CR CONTACT PERSON: `�-�. Name: rL...o Irlrow,nc, l Pe,,(4.&_ Mailing Address: -7 47® S of d M,4-,++i �L1q,5 P'U 6 s Phone#: (D 3 9 3 9 2 �_7 0 q / Email: Pe'rm'+5 e, C a6 .s i DESIGN PROFESSIONAL INFORAflATION: Name: Mailing Address: Phone#: Email: CONT eACTOR INFORMAITIONs Name: �rt e-Me l 5 y1trq 31 L L'Ci Mailing Address: 1 4V S® d O �ia�I ��c ��` ►n ➢ q� Phone#: ,-� D 4 ) d Email: � � Ws 0' cos vs' IDESCPJPTION.OF PRCPO51-ID`C011IS6Q UC—TION ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: ther I T)5+A--d �.So )a C PV 5!d $-7 , K-w $ 4 3. L/3 S, w Will the lot be re-graded? ❑Yes;.No Will excess fill be removed from premises? ❑Yeso ,I j 1 PROPERTY INFORMATION Existing use of property: S Intended use of property: Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes PQo IF YES, PROVIDE A COPY. he k Box After'Readi rig:, The owner/contractor/design professional is responsible for affdrainage and storm,water issues as provided by, apter 236 of theTown Code.APPLICATION IS HEREBY MADE_to the Building Department for the issuance of a Building.Permit pursuant to.the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for kemoval or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.,False statements made herein are- punishable as a Class A misdemeanor pursuant to Section 210AS of the New York State Penal Law. Application Submitted B rint name):Lorraine DiPenta PP BY(print ) ®Authorized Agent ❑Owner Signature of Applican (Date: STATE OF NEW YORK) SS: COUNTY OF Suffolk ) Lorraine DiPenta being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Contractor (Contractor,Agent,Corporate Officer,etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this day of 111cir-c- 2p 2 S No ublic PROPERTY OWNER AUTHORIZATION (Where the applicant is not the owner) I, Slew-rrl S+CL++%0u, residing at c290 *Tke,,S LAn , E&S4 a-rl�n do hereb authorize y C C17K-ILA E1IL"4 L.t.0 / o rr� to apply on I� y .«q 3 my behalf he Tow o So old Buildin Department for approval as described herein. �X_� Owner's Signature LOUIS J ROMEO Date J 4 e—v,c,n S L& �D g d _ < Notary Public,State of New York' T f !S 06314813 Qualified m Suffolk County Print Owner's Name Commission Expires November.17,20 2 �S11ff04ek, BUILDING DEPARTMENT- Electrical Inspector G TOWN OF SOUTHOLD a y� Town Hall Annex - 54375 Main Road - PO Sox 1179 � x� oy y� Southold, New York 11971-0959 �ipl �a444 Telephone (631) 765-1802 - FAX (631) 765-9502 lamesh(d-soutlholdto+wnny gov—seand(a7southoldtownny aov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (Au Information Required) Date: Company Name: E I + C_ � Electrician's Name: �' �d'a��9 License No.: i; 19 a t-�j5 Elec. email: Pf_rrfj A�-s C Elec. Phone No: , s -?9_-2,9�3 [ l request an email copy of Certificate of Compliance Elec. Address.: ® _S:,LL�neL 4vae— �I c�-�'B-B �ar��,D� ��, l �- JOB SITE INFORMATION (All Information Required) Name: S-eyt, S-� &� h o u ` Address: ago -TyLt s 0y+ L.4 �tQ� Cross Street: ryN& Phone No.: q, 1 a4b BIdg.Permit#: email: Parma- S c e,QS S. C Tax Map District: 1000 Section: 6 Block: Q Lot: Oc9 [BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): -P I V.S �VN ['0 0 g- rn 36' - rV10"k-S Square Footage: Circle All That Apply: Is job ready for inspection?: 0 YES U NO ❑Rough In ❑ Final Do you need a Temp Certificate?: ❑ YESFj�NO Issued On Temp Information, (All information required) Service Size❑1 PhD Ph Size: A #Meters Old Meter# ❑New Service[-]Fire Reconnect[]Flood Reconnect❑Service Reconnect QUnderground❑Overhead #Underground Laterals Ell 2 El H Frame F71 Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION r . rt`SUFFO(�'` BUILDING DEPARTMENT- Electrical! Inspector TOWN OF SOUTHOLD s ® Town Hall Annex - 54375 Main Road - PO Sox 1179 N N ae J o P �` Southold; New York 11971-0959 ��®d ��� Telephone (631) 765-1802 - FAX (631) 765-9502 jameshi�southoldtownny 4ov - sea ndCd-)southoldtownny gov APPLICATION FOR ELECTRICAL. INSPECTION ELECTRICIAN INFORMATION (Au Information Required) Date- � 'St.o 5 Company Name- E -e mee i+ c_ nz L_t c, I illElectrician's Name: I �' License No.: j; lcl e Elec. email: Pe rrf,s 4. Elec. Phone No: .;,s 2q- ,?9,qI3 [ 1 request an email copy of Certificate of Compliance Elec. Address.: 5�a%-� - JOB SITE INFORMATION (All Information Required) dame: e.�� 5-�-�,-�h o u k Address: 02 Q O ^C11L, S ay+ ��� Cross Street: rr-%A_i n Phone No.: Bldg.Permit#: email- PerM. a Q, le—QIs Tax Map District- 1000 Section: Block: Lot: 00 [BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly)- 36' - rVA0 `'kS Square Footage: Circle All That APPIyo Is job ready for inspection?: ❑ YES N NO ❑Rough In ❑ Final Do you need a Temp Certificate?: ❑ YE�Z NO Issued On Temp Information: (All information required) Service Size❑1 Ph[]3 Ph Size: A # Meters Old Meter# 1E]New Service Fire Reconnect❑Flood Reconnect❑Service Reconnect®Underground®Overhead # Underground Laterals 1 2 H Frame D Pole Work done on Service? D Y N Additional Information: PAYMENT DUE WITH APPLICATION (7 A4 11 _ Q3::S- A- C PERMIT# Address:- .. Switches . Outlets GFI's 1 Surface Sconces H H's UC Lts Fridge HW POOL Fans Mini Fr. W/D Panel Pump Exhaust Oven Sump Heater Trnsfmr Smokes DW Generator Salt Gen. Carbon Micro GrbDis Water Bond Lights Heat Pucks ERV HOT TUB/SPA Inst Hot DeHum Transfer Disc Combo Cooktop Minisplit Blower AC AH Hood Blower Service Amps Have Used Sub Amps Have Used Comments i'� APP 0 ED AS NOTED FEE-J� 1 BY NOTIFY BUILDING DEPARTMENT AT 631-765.1802 8AM TO 4PM FOR THE FOLLOWING INSPECTIONS: 1. FOUNDATION-TWO REQUIRED FOR POURED CONCRETE 2. ROUGH-FRAMING A PLUMBING 3. INSULATION - ELECTRICAL 4. FINAL-CONSTRUCTION MUST INSPECTION REQUIRED BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTON ERRORS COMPLY WITH ALL CODES OF NEW YORK STATE&TOWN CODES AS REQUIRED AND C NDITIONS OF . SOUTHO OWN ZBA SOUTH TOWN PLANNING BOARD SO LD TOWN TRUSTEES N.Y. ,DEC OLD HPC D OCCUPANCY OR USE IS UNLAWFUL WITHOUT CERTIFICAT OF OCCUPANCY Page 1 of 2 4 03/02/2025 Current Renewables Element Energy LLC Engineering 7470 Sound Avenue, Mattituck, NY, 11952 Subject: Structural Certification for Installation of Residential Solar Job: Stathoudakis, Steve - 280 The Short Lane Project Address: 280 The Short Lane, East Marion, NY, 11939 Attn.: To Whom It May Concern Observation of the condition of the existing framing system was performed by an audit team of Element Energy LLC. After review of the field observation data, structural capacity calculations were performed in accordance with applicable building codes to determine adequacy of the existing roof framing supporting the proposed panel layout. Please see full Structural Calculations report for details regarding calculations performed and limits of scope of work and liability. The design criteria and structural adequacy are summarized below: Design Criteria Code: 2020 NYSBC, IBC 2018, ASCE 7-16 Risk Category: II Ult Wind Speed: 128.0 mph Ground Snow: 25.0 psf Min Snow Roof: N/A ri NEW 41 Q P, ZgNoil yt yt Current Renewables Engineering Inc. e Professional Engineer info@currentrenewableseng.com � 01084 Exp.01/31/2028 Signed on:03/02/2025 3600 Lime St Bldg 2,Ste#224, Riverside,CA 92507 (951)203-5933 info@currentrenewableseng.com Page 2 of 2 I Summaries• Check 1: Shingle roofing supported by 2x12 Rafter @ 16 in. OC spacing. The roof is sloped at approximately 30 degrees and has a max beam span of 19.0 ft between supports. Roof is adequate to support the imposed loads. Therefore, no structural upgrades are required. 3600 Lime St Bldg 2,Ste#224, Riverside,CA 92507 (951)203-5933 info@currentrenewableseng.com OF NEW ROOF MOUNT SOLAR PERMI ' PACKAGE ��PpPHk14 yO,p� STEVE STATHOUDAKIS ti r vl �u 14.875 KW DC GRID TIED PHOTOVOLTAIC SYSTEM 101084 SHORT LN EAT MARION 280 THE SHO S , NY 11939 Exp.01/31/2028 STAMPED 03/02/2025 AERIAL VIEW VICINITY VIEW CODE INFORMATION GENERAL NOTES THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW.REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT THE INSTALLATION OF SOLAR ARRAYS AND PHOTOVOLTAIC 1. LOCAL UTILITY PROVIDER SHALL BE NOTIFIED PRIOR TO USE AND ACTIVATION OF ANY PRIOR WRITTEN APPROVAL FROM CURRENT POWER SYSTEMS SHALL COMPLY WITH THE FOLLOWING CODES. SOLAR PHOTOVOLTAIC INSTALLATION RENEWABLES ENGINEERING INC. 2020 BUILDING CODE OF NEW YORK STATE 2. THIS PROJECT SHALL COMPLY WITH LOCAL ORDINANCES 2020 RESIDENTIAL CODE OF NEW YORK STATE 3. PROPER ACCESS AND WORKING CLEARANCE WILL BE PROVIDED Current 2020 EXISTING BUILDING CODE OF NEW YORK STATE 4. ALL ELECTRICAL WORK SHOWN ON THESE PLANS WILL BE COMPLETED BY THE ;. - lewables 2020 FIRE CODE OF NEW YORK STATE UNDERSIGNED 2017 NEW YORK STATE ELECTRICAL CODE 5. ALL APPLICABLE PV EQUIPMENT LISTED AND COMPLIANT WITH UL2703,UL1741 AND Engineering UL1703 6. ALL ROOF PENETRATIONS TO BE SEALED WITH A HIGH PERFORMANCE ROOF SEALANT CURRENT RENEWABLES ENGINEERING INC. • SUCH AS GEO CEL 2300 CLEAR SEALANT 3soo Lime StrePmjeg z Rive ebo r szsol 7. THE SYSTEM WILL NOT BE INTERCONNECTED UNTIL APPROVAL FROM THE LOCAL Email:Pmjects=creng.solar Website_.www.cren9.co JURISDICTION AND THE UTILITY IS OBTAINED PHONE 951)-zo4-5492 AHJ: TOWN OF SOUTHOLD 8. THE SOLAR PHOTOVOLTAIC INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING, CONTRACTOR INFO E MECHANICAL,OR BUILDING ROOF VENTS S 9. IF THE EXISTING MAIN PANEL DOES NOT HAVE VERIFIABLE GROUNDING ELECTRODE, IT IS THE NECESSARY TO INSTALL SUPPLEMENTAL NG ELECTRODE LEGEND 10. EACH MODULE WILL BEGROUN EDU L2703 OR UL 17R03 APPROVED USING THE SUPPLIED CONNECTION POINTS IDENTIFIED ON THE MODULE AND THE mom UTILITY METER PM PRODUCTION METER MANUFACTURER'S INSTALLATION INSTRUCTIONS" ��SYS �0_1 1 t A LADDER SHALL BE IN PLACE FOR THE INSPECTION IN COMPLIANCE WITH OSHA MSP MAIN SERVICE PANEL wV INVERTER REGULATIONS 12. MAX HEIGHT OF MODULES OFF OF ROOF FACE:<6" ELEMENT ENERGY LLC. 747050UND AVENUE,MATTITUCK BUILDING INFORMATION C❑ COMBINER � JUNCTION BOX 13. PHOTOVOLTAIC SYSTEM WILL COMPLY WITH 2O17 NEC. NEwvoRK,n9sz 14. PHOTOVOLTAIC SYSTEM INVERTER IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY PH:(631)779 7993 2 STORY HOUSE SINGLE FAMILY RESIDENCE � AC DISCONNECT GROUNDED IN THE INVERTER,AND SYSTEM COMPLIES WITH 690.35. se i"cencs-ME-52689 UB SUB PANEL Licence-ME-52689 15. MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. (MASTER ELECTRICIAN) ❑ MODULE 16. INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. Licence-HI-67461 LP BACKUP LOAD PANEL (SUFFOLK HOME IMPROVEMENT) CONSTRUCTION TYPE: V-B OCCUPANCY: R3/U 17. ELECTRICAL EQUIPMENT AND MATERIAL TO BE LISTED,LABELED,AND INSTALLED PER ROOF OBSTRUCTIONS THE NEC,THE INSTALLATION STANDARDS/MANUFACTURER'S RECOMMENDATIONS AND IQ IQ CONTROLLER 2 IF REQUIRED A RECOGNIZED ELECTRICAL TESTING LABORATORY. STEVE STATHOUDAKIS 36"ACCESS PATHWAYS 18. CONDUITS EXPOSED TO SUNLIGHT ON ROOF SHALL BE LOCATED NOT LESS THAN 7/8', APN : 1000030000200000000 280 THE SHORT LN,EAST ATT BATTERY ABOVE ROOF SURFACE. MARION, NY 11939 SHEET INDEX _ 18"ACCESS PATHWAYS 19. IN EXPOSED LOCATIONS,WIRING AND CABLING SHALL BE IN CONDUIT OR CABLE SHALL QH Q.HOME HUB BE RATED FOR EXPOSURE;TYPE NM CABLE ALLOWED IN PROTECTED LOCATIONS. AHJ TOWN OF SOUTHOLD PV-1.0 COVER PAGE - ROOF ACCESS POINT WITHIN ATTIC SPACES,ALLOWED TO RUN TYPE NM(ROMEX) 10/3 OR 12/3 CONDUCTORS MAIN BREAKER AC ESS DISCONNECT THROUGH OPEN SPACE OR TYPE THHN IN MINIMUM 3/4"ALUMINUM CONDUIT UTILITY PSEG LONG ISLAND PV-2.0 SITE PLAN ENCLOSURE MBE 20. MATERIALS,EQUIPMENT AND INSTALLATION SHALL COMPLY WITH THE REQUIREMENTS, LOAD CENTER STANDARDS,RULES AND REGULATIONS OF THE FOLLOWING AND BE MOST SUITABLE PV SUMMARY PV-2.1- 'ROOF PLAN- - Ts AUTOMATIC TRANSFER TO THE PURPOSE INTENDED: FIKWDC) STC 425 X 35 - 4 875 PV-3.0 STRUCTURAL SWITCH O SEPTIC TANK PTC 3981 X 35 =13.934 SYSTE SIZE PV-4.0 ELECTRICAL 3LD 240 PERMANENTANCHOR LEACH LINES 1120CaIN KO SOLAR PV 4.1 ELECTRICAL SLD WIND SPEED 128 35 1KM425N-54HL4-B TTEMPORARYANCHOR PROPANETANK ENPHASE SNOW LOAD 25 35 IQ8MC-72-M-US PV-4.2 ELECTRICAL PHOTOS IL INSTALLER LADDER WELL EXPOSURE CATEGORY C PV-5.0 BOM O POWER LINES PV-6.0 SIGNAGE & PLACARD S STUB-OUT NO LADDER ACCESS P"i SPECS+ ® SKYLIGHT (STEEP GRADE - - -- - - - - OR GROUND LEVEL Rev Description Date - -- -- - - RESTRICTED ACCESS OBSTRUCTIONS) 0 INITIAL DESIGN 2/28/2025 - - - - - - - As GAS SHUT OFF A - _ - - - - -- - - CONDUIT Hzo WATER SHUT OFF P ROJECTNA -- - -- - - - -- - - - - 2/28/2025 - - - - - - O SERVICE DROP ER PV-1.0 -- -- RAIL TITLE - - - -- - RAFTER - - - - COVER PAGE ATTACHMENT R324.6.1 PATHWAYS: NOT LESS THAN TWO MINIMUM 36-INCH WIDE PATHWAYS ON _ __ _ LEGEND ROOF ,�,OF NEW,,, SEPARATE OF PLANES, 61 FROM LOWEST ROOF EDGE TO RIDGE,SHALL BE PROVIDED ON —�--=__�/11 �'t P PSH ZAp0 ALL BUILDINGS. --�-- I / i AT LEAST ONE PATHWAY SHALL BE PROVIDED ON THE STREET OR i UM UTILITY METER DRIVEWAY SIDE OF THE ROOF. I , FOR EACH ROOF PLANE WITH A PHOTOVOLTAIC ARRAY,A MINIMUM I SP MAIN SERVICE PANEL 36 INCH-WIDE PATHWAY FROM THE LOWEST ROOF EDGE TO RIDGE SHALL BE PROVIDED ON THE SAME ROOF PLANE OR STRADDLING - THE SAME AND ADJACENT ROOF PLANES.PATHWAYS SHALL BE PROPERTY LINE C❑ COMBINER N V OVER AREAS CAPABLE OF SUPPORTING FIRE FIGHTERS Qp 101084 ACCESSING THE ROOF.PATHWAYS SHALL BE LOCATED IN AREAS I AC DISCONNECT WITH MINIMAL OBSTRUCTIONS SUCH AS VENT PIPES,CONDUIT,OR MECHANICAL EQUIPMENT. i MODULE R324.6.2 SETBACK AT RIDGE: i ROOF OBSTRUCTIONS gyp'01/31/2028 FOR PHOTOVOLTAIC ARRAYS OCCUPYING NOT MORE THAN 33 'ti''• STAMPED 03/02/2025 PERCENT OF THE PLAN VIEW TOTAL ROOF AREA,NOT LESS THAN I •. ® 36"ACCESS PATHWAYS AN 18 INCH CLEAR SET BACK IS REQUIRED ON BOTH SIDES OF A 1 = '• .' .!' % THESE DRAWINGS ARE SUBJECT TO COPYRIGHT HORIZONTAL RIDGE. I :�'' PROTECTION BY US LAW.REPRODUCTION IN ., 18��ACCESS PATHWAYS ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT FOR PHOTOVOLTAIC ARRAYS OCCUPYING MORE THAN 33 1 PRIOR WRITTEN APPROVAL FROM CURRENT PERCENT OF THE PLAN VIEW TOTAL ROOF AREA,NOT LESS THAN A f RENEWABLES ENGINEERING INC. 36-INCH CLEAR SET BACK IS REQUIRED ON BOTH SIDES OF A FENCE I ~ ROOF ACCESS POINT HORIZONTAL RIDGE. 152'_411 t•;' •� R324.6.4 EMERGENCY ESCAPE AND RESCUE OPENING:PANELS .� :: ' Current AND MODULES INSTALLED ON DWELLINGS SHALL NOT BE PLACED I ,. I Renewables THE PORTION OF ROOF THAT IS BELOW AN EMERGENCY ESCAPE I ' Engineering AND RESCUE OPENING.A 36-INCH-WIDE PATHWAY SHALL BE 1 PROVIDED TO THE EMERGENCY ESCAPE AND RESCUE OPENING. i 1 CURRENT RENEWABLES ENGINEERING INC. ''•'�. P 3600 Lime Streel,Bldg 2 Riverside,CA 92501 NOTES: I Emil,Projects@creng.solar 1. MINOR FIELD ADJUSTMENTS ALLOWED BASED ON ACTUAL ''1 Websile viww.creng.co SITE CONDITION AND MEASUREMENTS. I y_:i PHONE 951)-204-5492 2. THE 30 SECOND SHUTDOWN REQUIREMENT IS INCORPORATED ;. CONTRACTOR INFO INTO THE 2017 NEC AND UL STANDARD 1741. — 3. EXISTING ROOF VENT SHOULD NOT BE COVERED. (0 c) i '.•. 0 ® �..� co ' M EZSYS ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK, FENCE/GATE NEW YORK.11952 ROOF ACCESS POINT I PH:(631)779 7993 FENCE/GATE i • Licence-ME 2689 `... a (MASTER ELECTRICIAN) Licence-HI-67461 1 •. / 10 1_711 (SUFFOLK HOME IMPROVEMENT) 61-811-j ROOF LINE I STEEE STATHOUDAKIS i I y • ROOF OBSTRUCTION 280 THE SHORT LN,EAST ENLARGED VIEW MARION, NY 11939 1 ��•:• i AHJ TOWN OFSOUTHOLD 1 AC ' ' 1 UTILITY PSEG LONG ISLAND •I •r. I ' . 1 ROOF ACCESS POINT SYSTEM SIZE PV SUMMARY ENLARGED VIEW STC 425 X 35 = 4.875 1 v J • +!• 1 PTC 398.1 1X1351=h1934 4'�•ti !' '••�• 1 SYSTEM SIZE (KWAC) 11.20 @240 C I �' •• : •`"� �' • ''�'•` 1 IN KO SOLAR MODULES 35 S1KM425N-54HL4-B • • '', • •' � " • 1 M S P `DRIVEWAY • .! ••8G1-211. I ENPH ' • >DRIVEWAY MICROINVERTER 35 IOBMC-7-72-M-US . .. 1 •A �i 1 .t •', . - Rev Description Date ;�'•••: 1 U M / .�4 :• PROPERTY LINE 0 INITIAL DESIGN 2/2 812 02 5 1 ` , '. 1 '. A 1 .' 1,r'•. ~ • # I PROJECT# NA 1 • • •••. .t' '! -•4 ; DATE DRAWN 2/28/2025 •'• •~ DRAWN BY E.R SITE PLAN ENLARGED VIEW - --�- ----- -`- • 751-1111 SHEET# PV-20 1 TITLE SCALE: 1/32" = 1'-0" TH E S H O RT LN SITE PLAN ARRAY AREA LEGEND Of NE►y y ROOF TOTAL ARRAY ROOF c�P P5N ZANp �'P ROOF #OF AREA AREA ROOF AZIMUTH AREA AREA uM UTILITY METER TILT MODULES (Sq.Ft.) (Sq.Ft.) COVERED BY COVERED BY sP ARRAY(%) ARRAY(%) MAIN SERVICE PANEL * y #1 30' 244' 28 588.56 3872 15.20 n W 19.00 C❑ COMBINER r^ _ #2 1 30' 154' 7 147.14 3872 3.80 1 AC DISCONNECT FQ 101084 MODULE pR FE ��Na ROOF OBSTRUCTIONS Exp.01/31/2028 ROOF#1 36"ACCESS PATHWAYS STAMPED 03/02/2025 THESE DRAWINGS ARE SUBJECT TO COPYRIGHT _ 1 8"ACCESS PATHWAYS PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT _ PRIOR WRITTEN APPROVAL FROM CURRENT RAIL RENEWABLES ENGINEERING INC. RAFTER ATTACHMENT Current Renewabies 40 Engineering CURRENT RENEWABLES ENGINEERING INC. _ 3600 Lime Stmet,Bldg 2 Riv rside,CA 92501 Email:Pmjects@cmng.solar Websile wwvr creng.co PHONE.(951)-204-5492 CONTRACTOR INFO (N)35 JINKO SOLAR JKM425N-54HL4-B — mum CZSYS - ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK �L NEW YORK,11952 STRUCTURAL NOTE)S' PH:(631)779 7993 r-6rr 1.THESE PLANS ARE STAMPED FOR STRUCTURAL CODE _ _ _ Licence-ME-52689 services@e2sys.com COMPLIANCE OF THE ROOF FRAMING SUPPORTING THE (MASTER n eLHI-67 61 PROPOSED PV INSTALLATION ONLY. _ _ _ _ (SUFFOLK HOME IMPROVEMENT) 2.THESE PLANS ARE NOT STAMPED FOR WATER _ LEAKAGE. 40 — _ _ I STEVE STATHOUDAKIS 3. PV MODULES, RACKING, AND ATTACHMENT 280 THE SHORT LN,EAST 11939 COMPONENTS MUST FOLLOW MANUFACTURER — — — I I I I TOWNMARIO S UT OLD GUIDELINES AND REQUIREMENTS. AHJ TOWN OFSOUTHOLD 4. PLEASE SEE THE ACCOMPANYING STRUCTURAL CALCULATIONS REPORT FOR ADDITIONAL INFORMATION. I I UTILITY PSEG LONG ISLAND 5. PRIOR TO COMMENCEMENT OF WORK, THE SOLAR _ INSTALLER SHALL VERIFY THE ROOF FRAMING INFO PV SUMMARY SYSTEM SIZE (KWDC) _ STC 425 X 35 = 4.875 BEFORE INSTALLATION AND NOTIFY THE E.O.R. IF THERE ' ! I I PTC 398.1 X 35 = 3934 IS ANY INCONSISTENCY BETWEEN SITE VERIFICATION _ _ I KWACMSIZE 1120 @240 AND FOLLOWING:2x12 RAFTERS @ 16"OC SPACING WITH MODULES 35 IN KO SO ARKM4HL4-B MAX UNSUPPORTED SPAN EQUAL OR LESS THAN 19 FT. FCC M P MICROINVERTER : 35 ENPHASE — 108MC-72-M-US ROOF#2 Rev Description Date 0 INITIAL DESIGN 2/2 812 02 5 A B ___________ PROJECT# NA r- � DATE DRAWN 2/28/2025 ROOF PLAN THE SHORT LN DRAWN BY ER SHEET# PV-2.1 2 I Um I TITLE SCALE: 1/811 = 1 -011 L_ ROOF PLAN TABLE 1 TABLE 2 �tof NEwy s, FRAMING TYPE RAFTER ROOF ROOF ROOFING FRAMING FRAMING OC MAX PENETRATION MAX �tP PSN ZApO� D.Q� NO. TILT TYPE TYPE SIZE SPACING SPACING OVERHANG s2 ATTACHMENT IRONRIDGE HUG ROOF 1 300 COMP SHINGLE RAFTER 2"X12" 16" 64" 24" r s3 RAIL IRONRIDGE XR-100 RAIL ROOF 2 300 COMP SHINGLE RAFTER 2"X12" 16" 64" 24" cn^ 101084 p� FE IONa Exp.01/31/2028 STAMPED 03/02/2025 THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW.REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. Current Renewables Engineering CURRENT RENEWABLES ENGINEERING INC. 3600 Lime Stmet,Bldg 2 Riverside,CA 92501 Email:Projects@cmng.solar Website:viww cm ng.co MODULE PHONE 9511-204-5492 CONTRACTOR INFO S3 TABLE : PENETRATION ARM S2 GUIDE FOR INSTALL E SYS ELEMENT ENERGY LLC. ROOF TWO OR MORE ROWS OF PANELS 7470 SOUND AVENUE,MATTITUCK, NEW YORK,11952 PH:(631)779 7993 services@e2sys.com Licence-ME-52689 _ (MASTER ELECTRICIAN) Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) 2.5"MIN.EMBED. I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I STEVE STATHOUDAKIS 280 THE SHORT LN,EAST (2)-#14 X 3" SELF DRILLING I MARION, NY 11939 STRUCTURAL SCREWS TO I I I I I I I I I I I I I I I I I I I I AHJ I TOWN OF SOUTHOLD S1 EXISTING STRUCTURE I I I I I I I I I I I I I I I I I I I I UTILITY PSEG LONG ISLAND II-A IL STACKED STAGGERED FULLY STAGGERED PV SUMMARY E N LA 1\R,/'V E D V I E S■W SYSTEM SIZE STC 425 X 35 = 4.875 (KWDC) PTC 398.1 X 35 = 3.934 ONE ROW OF PANELS SYSTEM SIZE(KWIC) 1120 @240 53' MIN KO OLAR N MODULES 35 IIKM425N_54 HL4-B 6 MICROINVERTER 35 ENP HASE IQ8MIC-72-M-US i. MODULE I I I I I I I I I I I I I I I I I I I I I I I I SEE ENLARGED VIEW FULLY STAGGERED STACKED/STAGGERED Rev Description Date —� 0 INITIAL DESIGN 2/28/2025 A B PROJECT# NA DATE DRAWN 2/28/2025 �- ROOF DRAWN BY E R SHEET# PV-3.0 TITLE ATTACHMENT DETAILS STRUCTURAL BACKFEED FUSE SIZING MAX. CQN -INUouS OUTPUT 1.33A @ 240V ELECTRICAL EQUIPMENT LIST 00, tE of 55 X 1.25 = 58.19AMPS 60A FUSES-OK S. NO. ITEMS DESCRIPTION QTY. UTILITY *y��PEL M�G'G 46 1 PV MODULE JINKO SOLAR 35 PSEG LI r JKM425N-54HL4-B METER NO. 98404286 2 MICROINVERTER ENPHASE IQ8MC-72-M-US 35 3 COMBINER ENPHASE IQCOMBINER 5 1 ACCOUNT NO. 9675016302 8�48% 60A RATED D222NRB �$S►Div, P 4 AC DISCONNECT SQUARE D KNIFEBLADE 1 sealed 05mar2025 mike@h2dc.com LOCKABLE NEMA 311 UL H2DC PLLC NY CoA#:PB-082933 LISTED ELECTRICAL ONLY PRE CONSTRUCTION DRAWING SET NOTE:THE CONNECTION BETWEEN THE PV PANEL AND MICRO-INVERTER IS VIA MC4 CABLE,WHICH IS (E)UTILITY METER TO UTILITY THESE N ARE SUBJECTT PROTECTION BY US LAW IN PRE-INSTALLED BY THE MANUFACTURER GRID ANY FORMIS EXPRESSLY REPRODUCTION FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT 3 RENEWABLES ENGINEERING INC (N) ENPHASE (E)150A RATED COMBINER BOX 5 MAIN SERVICE PANEL Current 1 PH,120/240V 60HZ (E)150A/2P MAIN _ Renewable`'• A CELL WIRE LESS BREAKER — Engineering 2 MODEM COMMS (TOP FED) CURRENT RENEWABLES ENGINEERING INC. 3600 Lime Stmet,Blog 2 Riverside,CA 92501 IQ GATEWAY Email Pmj crenects@crengsolar bsite BRANCH 1 OF 12 www. 4 PV MODULE N PHONE 951-204-592 (N)15A CONTRACTOR INFO I I I BRANCH 2 OF 12 N I (N)20A/T� I • (N)LINESIDE TAP VIA UL PV MODULE I /� I •� LISTED CONNECTOR Idom I (N)20A I I -- - - 4 CZSYS�L (N)FUSED •� (N)20A/� AC DISCONNECT (N)60A FUSE /'� • ELEMENT ENERGY LLC. I I 7470 SOUND AVENUE.MATTITUCK, I I I •1 NEW YORK.11952 `———————— , —— I I •, \ PH:(631)779 7993 TL-------_— __—___ ---__� ser ces@e2sys.com L————— licence-ME-52689 BRANCH 3 OF 11 I I PV MODULE N r----- --- I (MASTER ELEC LAN t I I Licence-HI-67461 _J (SUFFOLK HOME IMPROVEMENT) J B C I STEVE STATHOUDAKIS MODULE MANUFACTURER JINKO SOLAR GEC COATED L——————————————— 280 THE SHORT LN,EAST #6AWG TO THE MARION, NY 11939 MAIN GROUND ROD (E)GROUNDING ELECTRODE _ MODULE MODEL JKM425N-54HL4-B CONDUCTOR #6 BARE COPPER AHJ TOWN OFSOUTHOLD MODULE(W) 425 UTILITY PSEG LONG ISLAND MODULE PTC(W) 398.1 PV SUMMARY MODULE Isc(A) 13.58 NOTE. FMICROINIVERTER STC 425 X 35 = 4,875 MODULE VOC(V) 38.95 1)CONDUIT AND CONDUCTORS SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTSPTC 398.1 x 3s = 3934 MODULE Imp(A) 13.13 AND ARE NOT MEANT T LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. 1120 @zao NOTE:MODULE Vmp IV) 32.37 EGC AT ARRAY SHALL BE PROTECTED FROM PHYSICAL DAMAGE. 2)ALL CONDUCTORS NOT UNDER ARRAY ARE TO BE IN CONDUIT MINIMUM 7/8"ABOVE ROOF WITH 35 J'INKO SOLAR PROPER JUNCTION BOX AT EACH END PER 690.31A JKM425N-54HL4-B 35 ENPHASE WIRE CALCULATION I I IIQ8MC-72-M-US STARTING STARTING TEMPERATURE ADJUSTMENT MAXIMUM CONDUCTOR CONDUCTOR CURRENT FACTOR FOR ADJUSTED CURRENT CONDUIT ALLOWABLE TEMPERATURE CORRECTION TAG DESCRIPTION APPLIED TO MORE THAN 3 CONDUCTOR APPLIED TO QTY. SIZE (AWG) SIZE&TYPE AMPACITY RATING (°C) CONDUCTORS FACTOR CONDUCTORS AMPACITY CONDUCTORS 310.15(B)(16) IN RACEWAY 310.15(B)(2)(a) 310.15(B)(3)(a) IN RACEWAY Rev Description Date 0 INITIAL DESIGN 2/28/2025 6 12 SKU:Q-12-RAW-300,THHN A A 1 8 THWN-2 BARE COPPER-(GROUND) N/A FREE AIR 30 90° 15.96 0.96 0.8 23.04 19.95 PROJECT# NA 3 6 THWN-2 COPPER-(L1,L2,N) DATE DRAWN 2/28/2025 B 3/4" PVC 75 90° 46.55 0.96 1 72.00 58.19 DRAWN BY ER 1 8 THWN-2 COPPER-(GROUND) SHEET# PV-4 0 3 6 THWN COPPER-(L1,L2,N) TITLE C THWN COPPER-(GROUND) 3/4" PVC 75 90° 46.55 0.96 1 72.00 58.19 ELECTRICAL 3LD 1 6 BACKFEED FUSE SIZING MAX. COiJTINUOUS OUTPUT 1.33A @ 240V ELECTRICAL EQUIPMENT LIST tE OF NFy�, S. NO. ITEMS DESCRIPTION QTY. *SG�PEL M�G'G� 4655 _ X 1.25 =�5819A�MPS �60ASES-OK UTILITY PSEGLI JINKO SOLAR 1 PV MODULE 35 JKM425N-54HL4-B METER NO. 98404286 I ` R1 2 MICROINVERTER ENPHASE IQ8MC-72-M-US 35 3 COMBINER ENPHASE IQCOMBINER 5 1 ACCOUNT NO. 9675016302 ( N�o A 08748% 60A RATED D222NRB OSSlO��P�' 4 AC DISCONNECT SQUARE D KNIFEBLADE 1 sealed 05mar2025 mikeC&h2dc.com LOCKABLE NEMA 311 UL H2DC PLLC NY CoA#:PB-082933 LISTED ELECTRICAL ONLY PRE CONSTRUCTION DRAWING SET NOTE:THE CONNECTION BETWEEN THE PV PANEL AND MICRO-INVERTER IS VIA MC4 CABLE,WHICH IS (E)UTILITY METER TO UTILITY THESE PROTECTION BY BY US LAW,SUBJECTPRODUCTION IN T PRE-INSTALLED BY THE MANUFACTURER GRID ANY FORM IS EXPRESSLY VFORBDDEN WITHOUT 3 PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. (N) ENPHASE (E)150A RATED COMBINER BOX 5 MAIN SERVICE PANEL Current 1PH,120/240V60HZ ( Renewables (E)150A/2PMAIN 2 A CELL MODEM WIRE LESS BREAKER Engineering COMMS (TOP FED) CURRENT RENEWABLES ENGINEERING INC. 3600 Lime Street,BIdg 2 Riverside,CA 92501 IQ GATEWAY Email:Pmjeas�c eng solar BRANCH 1 OF 12 PV MODULE N Websi[e WWwcrengco PHONE:(951-204-5492 ' (N)15A. . . CONTRACTOR INFO BRANCH 2 OF 12 N (N)20A./i�� (N)LINESIDE TAP VIA UL Im ® m PV MODULE \\ •�• LISTED CONNECTOR (N)20%/ . 4 • CZ SYS (N)20A//I\ (N)FUSED r\ AC DISCONNECT (N)60A FUSE ELEMENT ENERGY LLC. /�� 7470 SOUND AVENUE,MATTITUCK •" I '• NEW YORK.11952 �\ PH:(631)779 7993 °l.l �' • services@e2sys.com Licence-ME-52689 BRANCH 3 OF 11 (MASTER ELECTRICIAN) Licence-HI-67461 PV MODULE N (SUFFOLK HOME IMPROVEMENT) B C STEVE STATHOUDAKIS MODULE JINKO SOLAR MANUFACTURER 280 THE SHORT LN, EAST (E)GROUNDING ELECTRODE MARION, NY 11939 MODULE MODEL JKM425N-54HL4-B CONDUCTOR #6 BARE COPPER AHJ TOWN OF SOUTHOLD MODULE(W) 425 UTILITY PSEG LONG ISLAND MODULE PTC(W) 398.1 PV SUMMARY MODULE Isc(A) 13.58 NOTE: SYSTEM SIZE(KWDC) STC 425 X 35 = 4.875 MODULE Voc(V) 38.95 1)CONDUIT AND CONDUCTORS SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS PTC 3981 IXI351= 3.934 SYSTEM SIZE MODULE Imp(A) 13.13 AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. 1120 Gzao MODULE Vm (V) 32.37 NOTEGC AT ARRAY SHALL BE PROTECTED FROM PHYSICAL DAMAGE. 2)ALL CONDUCTORS NOT UNDER ARRAY ARE TO BE IN CONDUIT MINIMUM 7/8"ABOVE ROOF WITH (KWAC) 1INKO SOLAR P PROPER JUNCTION BOX AT EACH END PER 690.31A MODULES 35 JKM425N-54HL4-B MICROINVERTER 35 ENPHASE WIRE CALCULATION QBMC-72-M-US STARTING STARTING TEMPERATURE ADJUSTMENT MAXIMUM CONDUCTOR CONDUCTOR CURRENT FACTOR FOR ADJUSTED CURRENT CONDUIT ALLOWABLE TEMPERATURE CORRECTION TAG DESCRIPTION APPLIED TO MORE THAN 3 CONDUCTOR APPLIED TO QTY. SIZE (AWG) SIZE 8r TYPE AMPACITY RATING (°C) FACTOR 310.15(B)(16) CONDUCTORS 310.15(B)(2)(a) CONDUCTORS AMPACITY CONDUCTORS Rev Description Date IN RACEWAY 310.15(B)(3)(a) IN RACEWAY 0 INITIAL DESIGN 2/28/2025 6 12 SKU:Q-12-RAW-300,THHN A A 1 8 THWN-2 BARE COPPER-(GROUND) N/A FREE AIR 30 90° 15.96 0.96 0.8 23.04 19.95 PROJECT# NA 3 6 THWN-2 COPPER-(L1,L2,N) DATE DRAWN 2/2 812 0 2 5 B 3/4" PVC 75 90° 46.55 0.96 1 72.00 58.19 DRAWN BY ER 1 8 THWN-2 COPPER-(GROUND) SHEET# PV-41 TITLE ELECTRICAL SLD 3 6 THWN COPPER-(L1,L2,N) LC THWN COPPER-(GROUND) 3/4" PVC 75 90° 46.55 0.96 1 72.00 58.19 1 6 EXISTING SERVICE PANEL PHOTOS eOFNFyy L Mac o r � p I a Vn �874BB �\ S10hP�'� j'- sealed 05mar2025 mike@h2dc.com 3^ ) �- c ELECTRICAL PLLRIC NY CoAk PB-082933 tV1 j ELECTRICAL ONLY PRE CONSTRUCTION DRAWING SET THESE DRAWINGS ARE SUBJECT TO COPYRIGHT 7 PROTECTION BV US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT 38 ! s S RENEWABLES ENGINEERING INC. Current 39 Renewabtes O Engineering �..,. CURRENT RENEWABLES ENGINEERING INC. t° 4 ' 3600 Lime StreeLBldg 2 Riverside,CA 92501 i 5 Email:Projects@cmng.solar { y F Website www crengco PHONE. 951)-204-5492 CONTRACTOR INFO ARM EZSYS ELEMENT ENERGY LLC. V 7470 SOUND AVENUE,MATTITUCK, == V NEW YORK,17952 PH:(631)779 7993 services@e2sys.com All Licence-ME-52689 Z (MASTER ELECTRICIAN) O Mrs " LK HOME IMPRO61 VEMENT) �• =Yi` (SUFFOLK HOME IMPROVEMENT) STEVE STATHOUDAKIS 280 THE SHORT LN,EAST 1 t MARION,NY 11939 f r AHJ TOWN OF SOUTHOLD UTILITY PSEG LONG ISLAND • �� PVSUMMARY SYSTEM SIZE STC 425 X 35 = 4.875 (KWDC) 1 R.� PTC 398.1 1 X 135 1= 3.934 F SYSTEM SIZE _ 11 20 @240 (KWAC) • y • 11NK0 SOLAR MODULES 35 1KM425N-54HL4-B r� I� MICROINVERTER 35 IQ8MC572-M-US Qb t5Rev Description Date 0 INITIAL DESIGN 2/28/2025 A B PROJECT# NA r 1. DATE DRAWN 2/28/2025 DRAWN BY E.R SHEET* PV-4.2 TITLE ELECTRICAL PHOTOS MATERIAL LIST ELECTRICAL EQUIPMENTS QTY. PART TYPE PART NUMBER DESCRIPTION 35 MODULE JKM425N-54HL4-B JINKO SOLAR JKM425N-54HL4-B 35 MICROINVERTER IQ8MC-72-M-US ENPHASE IQ8MC-72-M-US 1 AC DISCONNECT D222NRB 60A RATED 240VAC NEMA 3R UL LISTED 1 COMBINER X-IQ-AM1-240-5 Enphase IQ Combiner 5 YRIGHT 2 TAP CONNECTORS IPC TAP IPC INSULATION PIERCING CONNECTORS THESE DRAWINGSUS LAW.ARE JEPRODUCCT TO PION,IN PROTECTION BY US LAW.REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. Current - Renewal, Engineering CURRENT RENEWABLES ENGINEERING INC. 3600 Lime Si 2 Riverside.CA 92501 Email Projects@crengsolar Website WWw.cre ng.co PHONE: 951)-204-5492 CONTRACTORINFO BREAKER/ FUSES aanZSYS� QTY. PART TYPE PART NUMBER DESCRIPTION C ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK, 2 FUSES 60A FUSES GENERAL 60A FUSES NEW YORK,11952 PH:(631)779 7993 3 COMBINER BREAKER 20A 2-POLE BREAKER(S) GENERAL 20A 2-POLE BREAKER(S) servicesLicence--ME-5E-5268989 (MASTER ELECTRICIAN) Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) STEVE STATHOUDAKIS 280 THE SHORT LN, EAST MARION, NY 11939 RACKING AHJ TOWN OFSOUTHOLD QTY. PART TYPE PART NUMBER DESCRIPTION UTILITY PSEG LONG ISLAND PVSUMMARY 42 RAILS & SPLICES XR-100-168B XR-100, 168" (14') BLACK SYSTEM SIZE S?C 425 X 35 = 4.875 (KWDC) 18 RAILS & SPLICES XR100-BOSS-01-M1 BONDED SPLICE, XR100 P?C 386, X 35 = 13934 46 CLAMPS & GROUNDING UFO-CL-01-B1 SYSTEM SIZEt2o @24GUNIVERSAL MODULE CLAMP BLACK KWA�'MODULES JINKOKM4 SOLAR JKM425N-54HL4-B 48 CLAMPS & GROUNDING UFO-END-01-B1 END FASTENING OBJECT (END CLAMP, 30-40MM), BLACK MICRDINVERTERENPHASE IQ8MC-72-M-US 12 CLAMPS & GROUNDING XR-LUG-03-Al GROUNDING LUG, LOW PROFILE 108 ATTACHMENTS QM-HUG-01-B1 HALO ULTRAGRIP, BLACK 216 ATTACHMENTS HW-RD1430-01-M1 RD STRUCTURAL SCREW, 3.01- 108 ATTACHMENTS BHW-SQ-03-Al SQUARE BOLT, BONDING HARDWARE Rev Description Date 0 INITIAL DESIGN 2128/2024 A B PROJECT# I NA DATE DRAWN 2/28/2025 DRAWN BY ER SHEET# PV-5.0 TITLE BOM CAUTION ��°F "Ew y'�PPE'L MULTIPLE SOURCE OF POWER r PHOTOVOLTAIC - M Fn _ w EQUIPPED WITH RAPID SHUTDOWN �87488 ss". P� 690.12 sealed 05mar2025 mike@h2dc.com H2DC PLLC NY CoAk PB-082933 STE WIP ELECTRICAL ONLY PRE CONSTRUCTION DRAWING SET I WITH R_ APID.SHUT'�DOWN PV ARRAY THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW.REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT TURN RAPID - , • PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. SHUTDOWN SWITCH TO RATED AC OUTPUT CURRENT - 46.55 ■ THE OFFII POSITION TO ACNORMAL OPERATING VOLTAGE • - Current SHUT DOWN PV SYSTEM 690.14,690.15,690.54 AC DISCONNECT '; Renewdbles AND REDUCE SHOCK El COMBINER = Engineering CURRENT RENEWABLES ENGINEERING INC. HAZARD IN THE ARRAY PM 3600 Lime aireet,Bltlg 2 Riverside,so r 92501 � ■• ■ • ■ Email:Pmjecls@crengsolar MAIN SERVICE PANEL Websile www.creng.w SOURCEPHONE: 951)-204-5492 OUTPUT CURRENT - 46.55AMPS' CONTRACTOR INFO RATED ACELECTRIC SHOCK HAZARD AC NORMALOPERATING • ` 41 VOLTS , DO NOT TOUCH TERMINALS �.. TEPAUdALs ON BOTH L.sE a LOAD SIDES -.4 ON MAY 13E ENERGIZED IN OPEN POSITION DO NOT DISCONNECT RISES UNDElit LOAD �l 690,54 AU CZSYSU THE DC OF THIS PI OPTIONAL SOLAR LOAD CENTER UNGROUNDED AND SYSTEM ARE UNGROUUNDED AND MAYBE ENERGIZED ELEMENT ENERGY L-C. PHOTOVOLTAIC SYSTEM 7470 SOUND AVENUE,MATTITUCK, ARRAY DC DISCONNECT NEW YORK,11952 PH:(631)779 7993 AUTHORIZED PERSONNEL ONLY servlces@e2sys.com UTILITY METER�u Licence-ME-52689 Note.WARNING labels must resemble format (MASTER ELECTRICIAN) m in example above with over-sized WARNING, (SU FFOLK HOME IMPROVEMENT) ,o M. TH E S H O RT L N- exclamation point in triangle,colors,etc. J/B cA N. M. a 0 Licence-HI-67461 m PHOTOVOLTAIC BACK-FED CIRCUIT BREAKER IN MAIN ELECTRICAL STEVESTATHOUDAKIS "WARNING" PANEL IS AC DISCONNECT PER NEC690.17 280 THE SHORT LN,EAST x x ea MARION, NY 11939 INVERTER OUTPUT • • AHJ TOWN OF SOUTHOLD D• • RELOCATE NEC 690.31(G)(3)&(4),CRC R324.7 UTILITY PSEG LONG ISLAND OVERCURRENT DEVICE WARNING" PV SUMMARY (UNLESS BUSBAR IS FULLY RATED) PHOTOVOLTAIC POWER SOURCE SYSTEM SIZE(KWDC) STC 425 X 35= 4875 705.12(D)(2) PTC 398.1 X 35 = 3,934 SYSTEM SIZE _ 11.20 @240 EVERY 10'ON CONDUIT AND ENCLOSURES MODULES 35 11NKO SOLAR 1KM425N-54HL4-B MICROINVERTER 35 ENPHASE NOTES APPENDIX(AS APPLICABLE FOR TO BE BUILT DRAWING SETS):(A)TOTAL AC VOLTAGE DROP NOT TO EXCEED 2%TO IQSMC-72-M-US INTERCONNECTION,<3%FROM INVERTER(S)TO UTILITY TRANSFORMER.(B)ALL CONNECTORS 75C RATED.(C)ALL CONDUCTORS COPPER,UNLESS OTHERWISE NOTED.(D)OUTDOOR EQUIPMENT NEMA3R.(E)ALL CONDUCTORS MUST BE PROTECTED FROM ACCESS BY NOTES: A FENCE OR SUITABLE COVER,OR OUT OF REACH.(F)PROPERTY LINES, BOUNDARIES AND ALL OTHER EXTERIOR MEASUREMENTS ARE FOR REFERENCE ONLY,AND MUST BE VERIFIED BY A LICENSED SURVEYOR OR CIVIL ENGINEER. (G)NO PVC ALLOWED ON ROOF OR IN 1. NEC ARTICLES 690 AND 705 AND NEC SECTION R324 MARKINGS ATTIC. (H)MC4 CONNECTORS MAY NOT BE JOINED WITH'MC4 COMPATIBLE'CONNECTORS.(1)TAP CONNECTIONS IN PANEL MUST NOT SHOWN HEREON. VIOLATE CONDITIONS OF ACCEPTABILITY FROM PANEL MANUFACTURER'S NRTL LISTING,OR FIELD LABEL REQUIRED.(J)PV WIRES MAY NOT BE LAID DIRECTLY ON ROOF. (K)TY WRAPS FOR WIRE MANAGEMENT MUST BE STRUCTURAL(S21)UL APPROVED,OR EQUAL.(L) 2. ALL MARKING SHALL CONSIST OF THE FOLLOWING: Rev Description Date DRAWINGS ARE DIAGRAMMATIC AND INDICATE GE-NERAL ARRANGEMENT OF SYSTEMS AND WORK.-CONDUIT ROUTING,WHEN INDICATED, A. UV RESISTANT SIGN MATERIAL WITH ENGRAVED OR 0 INITIAL DESIGN 2/28/2025 DOES NOT SHOW ALL OFFSETS, DROPS,AND RISES OF RUNS.(M)BURIED CONDUITS UNDER AREAS SUBJECT TO VEHICLE TRAFFIC MACHINE PRINTED LETTERS OR ELECTRO-PLATING. A REQUIRE MIN 24"COVER. (N)NM-B OR PAPER INSULATED CONDUCTORS MAY NOT BE USED EXTERIOR. (0)THE DEVELOPER IS REQUIRED B. RED BACKGROUND COLOR WHITE TEXT AND LINE 13 TO CONFIRM EXISTING ELECTRICAL SERVICE SIZE FROM THE UTILITY,AND MAY NOT RELY S-OLELY ON EXISTING BREAKER SIZES.(P) WORK. PROJECT# NA CONNECTING TO UTILITY EQUIPMENT REQUIRES PRIOR UTILITY CONSENT.(Q)WHEN BUILDING PV SYSTEMS WITH POWER LINE DATE DRAWN 2/28/2025 COMMUNICATIONS FOR RSD SOLUTIONS, FOLLOWING MANUFACTURERS INSTRUCTIONS ON CONDUCTOR AND CONDUIT SPACING IS C. AERIAL FONT. PARAMOUNT,OR HAZARD MAY RESULT.(R)NOTIFY ELECTRICAL ENGINEER WHO'S SEAL IS ON THIS DRAWING PRIOR TO ANY AND ALL 3. ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN DRAWN BY E R CHANGES IN DESIGN. (S) PROJECT RELATED SIGNAUCOMMUNICATION CONDUCTORS MAY ONLY BE RUN IN THE SAME CONDUIT WITH THE LOCATIONS SPECIFIED. SIGNAGE CANNOT BE SHEET# PV-60 POWER CONDUCTORS IF THEIR RATING FOR THE OUTER MOST JACKET IS EQUAL TO OR GREATER THAN THE INSULATION REQUIRED FOR THE HIGHEST VOLTAGE POWER CONDUCTOR CIRCUIT THAT THEY ARE SHARING THE RESPECTIVE CONDUIT WITH. HAND-WRITTEN. TITLE 4. SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH SIGNAGE POP-RIVETS OR SCREWS. ENGINEERING DRAWINGS MECHANICAL CHARACTERISTICS EAGLE Front Side Back nw.r s No.of Half Celts 106 12 x 54; Dimensions 1722 x 1134 x 35mm(67.79 x 44.65 x 1.38 inch) s 1 Weight 22.Okg 148.51bsl THEMOST Front Glass High Tr Anti-Reflection Coating s i� High Transmission,Low Iron,Tempered Glass Frame Anodized Aluminum Alloy THESE DRAWINGS ARE SUBJECT TO COPYRIGHT R _J L PROTECTION BY US LAW. REPRODUCTION IN Junction Box Rated -,s ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT DEPENDABLE E 12 AWG - � Output Cables 12 AWG,1400mm 155.12in1 or Customized Length PRIOR WRITTEN APPROVAL FROM CURRENT SOLAR PRODUCT - RENEWABLES ENGINEERING INC i Connector Staubli MC4 _ Fire Type Type 1 Pressure Rating 540OPa(Snow)&240OPa[Wind) Current ,,znewables EAGLE 54HM G6 _ Engineering TEMPERATURE CHARACTERISTICS CURRENT RENEWABLESENGINEER)NGINC. 420-440 WATT • N-TYPE TOPCON Temperature Coefficients ofPmax -0.29';t,°C 3600 Lime Stmet.Bldg 2R-mide.CA92501 Length:t 2mm Email PMjeds@creng solar • (�'1 Width:t 2mm Temperature Coefficients of Voc -0.25%/°C `"`•'�-crergco Positive power tolerance of 0-+3% I ) I I PHONE 9511-204-5492 1 u Height t 1mm Temperature Coefficients of Isc 0 045%/°C Row Pitch:t2mm CONTRACTORINFO .-. Nominal Operating Cell Temperature INOCTI 45t2°C • NYSE-Listed since 2010,Bloomberg Tier 1 manufacturer • Top performance in the strictest 3"party labs ELECTRICAL PERFORMANCE&TEMPERATURE DEPENDENCE MAXIMUM RATINGS • Automated manufacturing utilizing artificial intelligence Current-Voltage&Power-Voltage Temperature Dependence Operating Temperature I°CI -40°C-.85°C CZSTSA • Vertically integrated,tight controls on quality Curves144OW) r_ of Isc,Voc,Pmax Maximum System Voltage 1000VDC ELEMENT ENERGY LLC. • Premium solar factories in USA.Vietnam,and Malaysia u w Maximum Series Fuse Rating 25A 7470 SOUND AVENUE,MATTITUCK, -xsx NEW YORK,11952 n. _ ,,. 3 10 ------- -- ---- --m i 1x. services@e2sys.com 89 KEY FEATURES ' _ ,r� PACKAGING CONFIGURATION Licence-ELECTRICIAN) u° (MASTER ELECTRICIAN) r� Licence-HI-67461 "~ 10 x (SUFFOLK HOME IMPROVEMENT) OSuperior Aesthetics i: [Two pallets=One stack) Black backsheet and black frame create ideal look for °• e- ,. ,:m 31pcs/pallets,62pcs/stack,806pcs/40 HO Container STEVE STATHOU DAKIS residential applications. voltage(v) N-Type Technology s 280 THE SHORT LN, EAST O N-typecellswithJinko'sin-houseTOPCon technology tl '" WARRANTY MARION, NY 11939 Celt Temperature offers better performance and improved reliability. lt Tempera i°cl I AHJ TOWN OF SOUTHOLD 25-year product and 30-year linear power warranty �� Thick and Tough 11'year degradation not to exceed 1%,each subsequent year not to Fire Type 1 rated module engineered with a thick frame, O exceed 0.4%,minimum power at year 30 is 87.4%or greater. UTILITY PSEG LONG ISLAND 2mm front side glass,and thick backsheet for added durability. PV SUMMARY SYSTEM SIZE STC 425 X 35 -14.875 Shade Tolerant ELECTRICAL CHARACTERISTICS (KWDC) Twin array design allows continued performance Module Type JKM420N-54HL4-B JKM425N-54HL4-B JKM430N-54HL4-B JKM435N-54HL4-8 JKM44ON-54HL4-B PTC 3981 X 35 =13.934 even with shading by trees or debris SYSTESTC NOCT STC NOCT STC NOCT STC NOCT STC NOCT KWACM SIZE 11 20 @240 ProtectedA Against All Environments Maximum Power IPmaxI 420Wp 316Wp 42SWp 320Wp 43OWp 323Wp 435Wp 327Wp 440Wp 331Wp MODULES 35 JINKO SOLAR G 9 JKM425N-54HL4-B Certrfied to withstand humidity,heat,rain,marine environments, Maximum Power voltage(Vmp1 32.16V 29.95V 32.37V 30.19V 32S8V 30.30V 32.78V 30.50V 32.99V 30.73V MICROINVERTER 35 EN PHASE wind,hailstorms,and packed snow. nsvcaz-M-us Maximum Power Current(Imp] 13.06A 1055A 13.13A 10.60A 13.20A 10.66A 13.27A 10.72A 13.34A 10.77A ® Warranty Open-circuit Voltage(Voc) 38.74V 36.80V 38.95V 37.00V 39.16V 37.20V 39.36V 37.39V 39.57V 37.59V 25-year product and 30-year linear power warranty. short-circuit Current(tsc) 13.51A 10.91A 13.58A 10 96A 13.65A 11.02A 13 72A 11.08A 13.80A 11.14A Module Efficiency STC 1%) 21.51% 21.76% 22.02% 22.28% 22.53% - *STC: • Irradiance 1000WW Cell Temperature 25'C AM=1.5 Rev Description Date • 1509001:2015 Duality Standards • ISO45001:20180ccupationat ^ CE C �` u' ® NOCT: • Irradiance 800W/m2 Ambient Temperature 20°C � AM=1.5 Wind Speed tin/s 0 INITIAL DESIGN 2i28i2025 • IS014001:2015ErmronfnentalStandards Health&Safety Standards L� ��� •Power measurement tolerance:t3% A • IEC61215.IEC61730 certified product= UL61730 certified products SaPa>r Ulm 8 The company reserves the final right for explanation onany of the information presented hereby.JKM420-440N-54HL4-8-F1-US $Ola t PROJECT# NA BUILDING YOUR TRUST IN SOLAR.WWW.JINKOSOLAR.US Jionlw BUILDING YOUR TRUST IN SOLAR.WWW.JINKOSOLAR.US •fin= DATE DRAWN 2/28/2025 DRAWN BY E.R SHEET# PV-7 0 TITLE MODULE SPEC ENPHASE czcou IQ8MC Microinverter INPUT DATA(DIC) UNITS IQ8MC-72-M-U5 Commonly used module pairings' w 260-460 wModule compatibility To meet compatibility.PV modules must be within the following max.input DC voltage and max.module IA Module compatibility can be checked at https//enphase-com/iretallers/mrcroimertws/calculator. THESE DRAWINGS ARE SUBJECT TO COPYRIGHT MPPT voltage range v 25-45 PROTECTION BY US LAW.REPRODUCTION IN Operating v 18-58 ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT 9 range 9 PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. MinJMax.start voltage v 22/58 Max.input DC voltage v 60 Current Max.continuous operating DC current A 14 C '�j',j,�(J�' ;t is i!1r i Y ual i,J 4 w S Max.input DC short�ircuit current a 25 11 I r = Engineering Max.module I A 20 Overvoltage class DC port 11 CURRENT RENEWABLES ENGINEERING INC. 3600 Lime Street,Bldg 2 Riverside,CA 92501 DC port backfeed current mA 0 Email:Projects(8creng.solar Websde-www.creng.co PV array configuration Ungrounded array;no addrbonal DC side protection required;AC side protection requires max 20 A per branch circuit PHONE: 951)-2045192 CONTRACTOR INFO Peak output power VA 330 315 Max.continuous output power va 320 310 Nominal grid voltage(L-L) v 240.split-phase(L-L).180• 208.single-phase(L-0.120` 92unh Q8 M C M i c ro i n ve rte r Easy to install Min./Max.grid voltage' v 211-264 183-229 C c SYS Our newest 108 Series Microinverters are the industry's first microgrid-forming`,software- Lightweight and compact with plug- Max.continuous output current A 133 1.49 defined microinverters with split-phase power conversion capability to convert DC power to and-play connectors Nominal frequency Hz 60 ELEMENT ENERGY LLC. AC power efficiently.The brain of the semiconductor-based microinverter is our proprietary Power line communication(PLC) Extended frequency range Hz 47-68 7470 SOUND AVENUE.MATTRUCK, application-specific integrated circuit(ASIC),which enables the microinverter to operate in between components NEW YORK 11952 rid-tied or off rid modes.This chi 1s built in advanced 55-nm tech with high-speed PH:(631)779 7993 g p �9y Pad Faster installation with simple two-wire AC short circuit fault current over three A._ 2.70 se"icesoe2sys.com digital logic and has superfast response times to changing loads and grid events.alleviating cabling cycles Licence-ME-52689 constraints on battery sizing for home energy systems. Max.units per 20 A(L-L)branch circuit' 12 10 (MASTER ELECTRICIAN) Licence-HI-67461 High productivity and reliability Total harmonic distortion <5 (SUFFOLK HOME IMPROVEMENT) Enphase % Produces power even when the grid is down* Overvoltage class AC port III STEVE STATHOUDAKIS More than one million cumulative hours AC port backfeed current mA 18 280 THE SHORT LN, EAST of testing MARION, NY 11939 Power factor setting 1.0 Part of the Enphase Energy System, I08 Series Microinverters redefine Class II double-insulated enclosure Grid-tied power factor(adjustable) 0.85 leading...0.851agging AHJ TOWN OF SOUTHOLD I08 Series Microinverters integrate with reliability standards with more than one Optimized for the latest high-powered the IQ Battery,10 Gateway.and the million cumulative hours of power-on PV modules Peak efficiency % 97.4 97.2 Enphase App monitoring and analysis testing,enabling an industry-leading CEC weighted efficiency 97.0 96.5 UTILITY PSEG LONG ISLAND software. limited warranty of up to 25 years. Microgrid-forming Nighttime power consumption mW 33 25 PV SUMMARY • Complies with the latest advanced grid SYSTEM SIZEMECHANICAL DATA UNITS (KWDC) STC 425 X 35= 4.875 support Ambient temperature range -40'C to 65`C(-40"F to 149'F) PTC 398.1 X 35= 3.934 • Remote automatic updates for the SYSTEM SIZE a latest grid requirements Relative humidity range 4%to 100%(condensing) (KWAC) 11.20 0240 N KO LA Configurable to support a wide range DC connector type Staubli MC4 MODULES 35 KM425N 541­11.4-B of grid profiles Dimensions(H•W•D);Weight 212 mm(8.3")•175 mm(6.9")•30.2 mm(1.2");1.1 kg(2.43 Ibs) MICROINVERTER 35 ENPHASE Connect PV modules quickly and easily IQ8 Series Microinverters are UL Listed 108 A%-M-US to the 108 Series Microinverters that have as PV rapid shutdown equipment and Meets CA Rule 21(UL 1741-SA)and IEEE Cooling Natural convection-no fans integrated MC4 connectors. conforms with various regulations when 1547:2018(UL 1741-SB) Ap proved for wet locations;Pollution degree Yes;PD3 installed according to the manufacturer's instructions. Enclosure Class 11 double-insulated corrosion-resistant polymeric enclosure NOTE: 108 Microinverters cannot be mixed together with Environ.category;UV exposure rating NEMA Type 6;outdoor prevrous generations of Enphase mic—nveners (107 Sen-106 Seines.etc)in the seine system. a • 10 Gateway c required to change the defauh grid CA Rule 21(UL 1741-SA).UL 62109-L IEEE 1547:2018(UL 1741-SB).FCC Part 15 Class B.ICES-0003 Class B,CAN/CSA-C22.2 NO.107.1-01 Rev Description Date •Meats UL 1741 only when nstalksd with IO System ComroNer 2 and 3 file at the time of installation to meet the local Certifications This product is UL Listed as PV rapid shutdownequipment and conforms with NEC 2014,NEC 2017,NEC 2020.and NEC 2023 section 600.12 and 0 INITIAL DESIGN 2128/202', pro Pr W Authority Having Jurisdiction(AHA requiraments. C22.1-2018 Rule 64-218-apid shutdown of PV systems for AC and DC conductors when installed according to the manufacturer's instructions. A 02023 Enphme Energy.All rights reserved.Erphase the a and CC logos,IQ and cannn other marks listed.t (1)No enforced DC/AC ratty. B -I.--.,nphase<om/trademark-usaoe- k ekne+are trademarks of Enphaw Energy.Inc-,the US and other co.mrws. (2)Nominal voltage range can be.,tended beyond romina'.It required b,the utility. Data subl.ct to charge. IQ6MC-MC4-DSH-00049-3o-EWUS-2023-110-18 (3)Lima5 may vary.Refer to local requirements to define the number of ntcroirnerters pe•branch;,your area. I08MC-MC4-DSH-00049-3.0-EN-US-2023-10-18 PROJECT# NA DATE DRAWN 2/2at2C25 DRAWN BY E.R SHEET# PV-7.1 TITLE MICROINVERTER SPEC ENPHASE. IQ Combiner 5/5C MODEL NUMBER IQ Combiner 5 with IQ Gateway printed circuit board for integrated revenue-grade PV IQ Combiner 5 production metering(ANSI C12.20±0.5%).consumption monitoring(±2.5%).and IQ (X-I0-AM1-240-5/X-IQ-AM1-240-5-HDK) Battery monitoring(±2.5%).Includes a silver solar shield to deflect heat. IQ-AM1-240-5-HDK includes a factory installed hold down kit compatible with all the ENPHASE circuit breakers mentioned in the Accessories and Replacement Parts section. IQ Combiner 5C with IQ Gateway printed circuit board for integrated revenue-grade PV production metering(ANSI C12.20±0.5%),consumption monitoring(±2.5%).and THESE DRAWINGS ARE SUBJECT TO COPYRIGHT IQ Combiner 5C IQ Battery monitoring(±2.5%).Includes Enphase Mobile Connect cellular modem PROTECTION BY US LAW REPRODUCTION IN UT (X-I0-AMt-240-5C/ X-IQ-AM1-240-5C-HDK) (CELL MODE M-M1-06-SP-05)'.Includes a silver solar shield to deflect heat. ANY FORM I TENAPPROVAL EXPRESSLY FORBIDDEN CURWITHRENT PRIOR WRITTEN APPROVAL FROM CURRENT IQ-AM1-24O-5C-HDK includes a factory installed hold-down kit compatible with all the RENEWABLES ENGINEERING INC. circuit breakers mentioned in the Accessories and Replacement Parts section. VJHAT S IN THE BOX Current X-I0-AMl-240-5-HDK IQ Gateway printed circuit board IQ Gateway is the platform for total energy management for comprehensive,remote q�2Y�►�h�� X-IQ-AM1-240-5C-HDK maintenance,and management of the Enphase Energy System X-IQ-AAAl-240-5 80 A busbar with support for one IQ Gateway breaker and four 20 A breakers for -� Engineering Busbar installing IQ Series Microinverters and IQ Battery 5P X-10-AM1-240-SC CURRENT RENEWABLES ENGINEERING INC. IQ Gateway breaker Circuit breaker,2-pole,10 A/15 A 3600 Lime Street Bldg 2 Riverside,CA 92501 Email:Projects@cmng solar WebsdProduction CT Pre-wired revenue-grade solid-core CT,accurate u to±0.5% HONE www omng co 9 P PHONE: 951)-204-5492 QCombiner 5/5C Consumption CT Two consumption metering clamp CTs,shipped with the box,accurate up to±2.5% CONTRACTOR INFO Smart IQ Battery CT One battery metering clamp CT,shipped with the box,accurate up to±2.5% The IQ Combiner 5/5C consolidates interconnection equipment into a single enclosure and Includes IQ Gateway for Control board for wired communication with IQ System Controller 3/3G and the streamlines IQ Series Microinverters and IQ Gateway installation by providing a consistent. communication and control CTRL board IQ Battery 5P pre-wired solution for residential applications.IQ Combiner 5/5C uses wired control Includes Enphase Mobile Connect Ilmum communication and is compatible with IQ System Controller 3/3G and IQ Battery 5P. 4G-based LTE-Ml cellular modem(CELLMODEM-MI-06-SP-05)with a 5-year T-Mobile (CELLMODEM-MI-06-SP-05),only Enphase Mobile Connect(only with IQ Combiner 5C) data plan C�SN.I The IQ Combiner 5/5C,IQ Series Microinverters.IQ System Controller 3/3G,and with IQ Combiner 5C =MOO IQ Battery 5P provide a complete grid-agnostic Enphase Energy System. Supports flexible networking:Wi-Fi, Accessories Kit Spare control headers for the COMMS-KIT-2 board ELEMENT ENERGY LLC. Ethernet,or cellular 4iCr rREPLACEMENTPARTS [NOTINCLUDED, ORDER 7470 SOUND AVENUE,MATTITUCK, NEW YORK,11952 Provides production metering CELLMODEM-Ml-06-SP-05 4G-based LTE-Mt cellular modem with a 5-year T-Mobile data plan PH:(631) (revenue grade)and consumption services@e2s2sys 779 c cooin monitoring CELLMODEM-M1-06-AT-05 4G-based LTE-M1 cellular modem with a 5-year AT&T data plan Licence- (MASTER ELECTRICIAN) N) Licence-HI-67461 Supports Eaton BR2XX,Siemens Q2XX,and GE/ABB THQL21XX Series circuit breakers (SUFFOLK HOME IMPROVEMENT) Easy to install Circuit breakers(off-the-shelf) (XX represents 10,15,20,30,40,50,or 60).Also supports Eaton BR220B,BR23OB,and Mounts to one stud with centered BR240B circuit breakers compatible with the hold-down kit. $TEV E STATH O��DAKI$ IQ Series Microinverters IQ System Controller 3/3G brackets The high-powered smart grid-ready IQ Series Provides microgrid interconnection device Circuit breakers(provided b Enphase) BRK-10A-2-240V,BRK(more elan,in the " ccess Ties BRK-15A-2P 240V B,and Microinverters(I06.IQ7,and I08 Series) (MID)functionality by automatically detecting Supports bottom.back,and side y p BRK 20A 2P 240V B(more details in the"Accessories"section) 280 THE SHORT LN, EAST simplify the installation process. grid failures and seamlessly transitioning conduit entries XA-SOLARSHIELD-ES Replacement solar shield for IQ Combiner 5/5C MAR I ON, NY 11939 the home energy system from grid power to Supports up to four 2-pole branch AHJ TOWN OF SOUTHOLD backup power. circuits for 240 VAC plug-in breakers XA-ENV2-PCBA-5 IQ Gateway replacement printed circuit board(PCB)for IQ Combiner 5/5C (not included) Hold-down kit compatible with Eaton BR-B Series circuit breakers(with screws).Not X-IQ-NA-HD-125A UTILITY PSEG LONG ISLAND 80 A total PV branch circuits required for X-I0-AMl-240-5-HDK/X-IQ-AMt-240-5C-HDK. Factory installed hold-down kit XA-COMMS2-PCBA-5 Replacement COMMS-KIT-2 printed circuit board(PCB)for IQ Combiner 5/5C PV SUMMARY SYSTEM SIZE Bluetooth-based Wi-Fi provisioning r KWDC) STC 425 X 35 -14 875 for easy WI-Fi setup PTC 398.1 IX1351=113934 r, Rating 80 A SYSTEM SIZE 11.20 @240 (KWAC) Reliable System voltage and frequency 120/240 VAC or 120/208 VAC,60 Hz MODULES 35 fINKO SOLAR IQ Battery 5P IQ Load Controller iKM425N-54HL4-B • Durable NRTL-certified NEMA type 3R Busbar rating 125 A MICROINVERTER 35 ENPHASE Fully integrated AC battery system.Includes Helps prioritize essential appliances during a enclosure I I IIQ8MC-72-M-US six field-replaceable I08D-BAT Microinverters. grid outage to optimize energy consumption Fault current rating 10 kAIC and prolong battery life. 5-year limited warranty Maximum continuous current rating(input from PV/ 2-year labor reimbursement program 64 A coverage included for IQ CombinerEriphase storage) U IE Rev Descrilion Date SKUs' Branch circuits(solar and/or storage) Up to four 2-pole Eaton BR.Siemens Q.or GE/ABB THOL Series distributed generation(DG)breakers only(not included) N0M L UL1741 Listed Maximum total branch circuit breaker rating(input) 80 A of distributed generation/95 A with IO Gateway breaker included P 0 INITIAL DESIGN 2/28/2025 IQ Gateway breaker 10 A or 15 A rating GE/Siemens/Eaton included A 5-year limited warranty Production metering CT 200 A solid core pre-installed and wired to IQ Gateway B 'For country-specific warranty information,seethe https://enphase.com/installers/resources/warranty page. PROJECT# NA A plug-and-play industrial-giade cell modem for systems of up to 60 mkroinverters.Available in the United States,Canada Memo.Puerto Rico,and the US Virgin Islands.where there Is adequate DATE DRAWN r 2024 Enphase Energy.All rights re—ea.Enphase,the a and CC logos.IO.and certain other marks listed at cellular service m the installation area. 2/28/2025 hnpsWenphase.com/trademark-usage-guidelines are trademarks of Enphase Energy.Inc.in the US.and other countries. DRAWN BY E.R Data subject to chwVw IOC-5-5C-DSH-00007-6.0-EN-US-2024-09-30 IOC-5-SC-DSH-00007-6.0-EN-US-2024-09-30 ISHEET# PV-7.2 TITLE COMBINER SPEC AOL IRONRIDGE XR Rail"' Family XR Rail° Family The XR Rail"Family offers the strength of a curved rail in three targeted sizes. Each size supports specific Solar Is Not Always Sunny design loads. while minimizing material costs. Depending on your location,there is an XR Rail!to match. Over their lifetime, solar panels experience countless THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW.REPRODUCTION IN extreme weather events. Not just the worst storms in years, Y ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT but the worst storms In 40 years. High winds Capable of _-._ -». - »- PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. ripping panels from a roof, and snowfalls weighing enough to buckle a panel frame. —"-----._.�, "-------..,; — Current XR Rails R%are the structural backbone ' -ienewables preventing these results.They resist uplift, XR10 XR100 XR1000 Engineering protect against buckling and safely XR10 is a sleek.low-profile mounting XR100 is a residential and commercial XR1000 is a heavyweight among and efficiently transfer loads into the rail.designed for regions with light or mounting rail.It supports a range of solar mounting rails.Its built to handle CURRENT RENEWABLES ENGINEERING INC. no snow.It achieves spans u to 6 feet, wind and snow conditions,while also extreme climates and spans u to 12 3600 Lime Street.Bldg 2 Riverside,CA 92501 building structure.Their superior p p p p Email Pmiects@creng solar while remaining light and economical. maximizing spans up to 10 feet. feet for commercial applications. Websile v ww creng co spanning capability requires fewer _ PHONE 951)-204-5492 roof attachments, reducing the 6'spanning capability 10'spanning capability 12'spanning capability CONTRACTOR INFO number of roof penetrations Moderate load capability Heavy load capability Extreme bad capability Clear&black anodized finish Clear&black anodized finish Clear anodized finish and the amount of Internal splices available Internal splices available Internal splices available installation time. ,. Rail Selection C2SYSS The table below was prepared in compliance with applicable engineering codes and standards.` Values are ELEMENT ENERGY LLC. based on the following criteria:ASCE 7-16, Gable Roof Flush Mount, Roof Zones 1 &2e, Exposure B, Roof 7470 SOUND AVENUE,MATTITUCK, Slope of 8 to 20 degrees and Mean BuildingHeight of 30 ft. Visit IronRid e.com for detailed certification letters. H:(v1)77 U9 529 p g g g9 services@e2sys,com Licence-ME-52689 ., •.• :.,,..' ,. ». ...,:,. .». • .. (MASTER ELECTRICIAN) Rail ' Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) • • , STEVE STATHOUDAKIS Force-Stabilizing Curve 90 Sloped roots generate both vertical and lateral T -20 280 THE SHORT LN, EAST forces on mounting rails which can cause them to None 1 MARION, NY 11939 bend and twist.The curved shape of XR Rails 140 XR10 XR100 XR1000 AHJ TOWN OF SOUTHOLD Is specially designed to increase strength in both directions while resisting the twisting.This unique feature ensures greater security during extreme 160 weather and a longer system lifetime. UTILITY PSEG LONG ISLAND _ 90 . PV SUMMARY 120 SYSTEM SIZE KWDC) STC 425 X 35 =14 875 20 — FTC 398.1 X 35 =13.934 140 SYSTEM SIZE(KWAC) 1120 @240 160 MODULES 35 1INKO SOLAR - .-,.,.._.e_ ..._.__.. .. 1KM425N-54HL4-B 30 90 MICROINVERTER 35 ENPHASE IOSMC-72-M-US 160 Compatible with Flat&Pitched Roofs Corrosion-Resistant Materials 90 XR Railsv are IronRidge'offers All XR Rails are made of 6000-series r 40 compatible with a range of tilt leg aluminum alloy,then protected with an 160 FlashFoot' and options for flat anodized finish.Anodizing prevents surface A other pitched roof roof mounting and structural corrosion,while also providing 80 160 Rev Description Date attachments. applications. a more attractive appearance. 120 160 0 INITIAL DESIGN 2/28/2025 'Table is meant to be a simplified span chart for conveying general rail capabilities.Use approved certification letters for actual design guicance. B PROJECT# NA DATE CI DRAWN BYE/R/2025 1 :II J SHEET# PV-7.3 TITLE RAIL SPEC IRONRIDGE QuickMount O Adaptive, Rafter-Friendly Installation The Respect Your Roof Deserves When integrating with a home. solar attachments • • A, THESE DRAVINGS ARE SUBJECT TO COPYRIGHT dependable for the lifetime of the rooftop. • PROTECTION BYUSLAW REPRODUCTION IN must be de p p ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT Due to recent Innovations. many asphalt shingles PRIORRE WRITTEN RENT ES ENGINEERING INC have bonded courses.A mount that protects without n the need to pry shingles can really speed things up. • • Current Halo UltraGrip`(HUG`)is here to respect the roof. -' Rtznewables Its Halo is a cast-aluminum barrier that encases the Ertgltle2f'Irlg UltraGrip, our industrial-grade.foam-and-mastic seal. This allows HUG to accelerate the installation CURRENT RENEWABLES ENGINEERING INC. 3600 Lime Street.Bldg 2 Riverside.CA 92501 process and provide the utmost in waterproofing Email Proie sQcrengSnlar Hit - rafteO Good to go! Miss the rafter?Try it again. I viww Websde .creng.co protection. Give your roof a HUG.` When • another a rafter,you can move on Place -than 3 screws miss the rafter PHONE 9511-204-5492 Only RD ' ll andfinal screw. secure six screwsto deckmount A. CONTRACTOR INFO Multi-Tiered Waterproofing HUG"utilizes a multi tiered stack of components to provide revolutionary Trusted Strength & Less Hassle ® — — Nallerproofing protection The Halo cast- < SKNIninum,raised-perimeter foundation the UttraGnp base—a foam Structural capacities of HUG' were reviewed in EZ SYSa mastic seal combination that many load directions, with racking rail running ELEMENT ENERGY LLC. '" water Intrusion by adhering 7470 SOUNO AVENUE,MATTITUCK, with the shingle Surface cross-Slope or up-slope In relation to roof pitch. NEW YORK,11952 PH.(631)779 7993 services@e2syscom Halo UludGnp is part For further details. see the HUG certification Licence-ME-52689 of the QulckMount' letters for attaching 9 to rafters and decking. (MASTER ELECTRICIAN) .� .'pfodupt line. ._... _.- _.._ -. - _. Licence-HI_67461 IMPROVEMENT) -.". _.-. (SUFFOLK HOME IMPROVV EMENT) —- IronRidge designed the HUG, in combination —UltraGrip` Seal Technology _ with the RD Structural Screw to streamline STEVE STATHOUDAKIS HUG UrcraGrip utilizes a state-of-tile- installs, which means the following: 280 THE SHORT LN, EAST art seal design that uses a unique, MARI ON, NY 11939 foam-and-mastic combination.The foam-backed adhesive provides an No prying shingles AHJ TOWN OF SOUTHOLD entirely new flashing system that No roof nail interference conforms and adheres to every nook - 25-Yea.,Warranty No pilot holes necessary and cranny of Composition shingles, Product gua'anteed free UTILITY PSEG LONG ISLAND filling gaps and shingle step-downs of Impairing Jetects. No sealant(in most cases) (up to 1/8"in height). • No butyl shims needed PVSUMMARY SYSTEM SIZE ,x (KWDC) STC 425 X 35 =14.875 a PTC 398.1 IX1351=113934 Attachment Structural Water Seal UL ' SYSTEM SIZE KWAC) 1120 @240 Loading • RatingsMODULES 35 JINKO SOLAR 1 KM425N-54HL4-B MICROINVERTER 35 ENPHASE IQ8MC-72-M-US Rafter&Deck Mounting Options The rafter-mounted Parts are designed HUG passed both Systems conform to Mount HUG'to with roof ratters.the root wR deck,or both our custom-engineered HUG has been and certified for the UL 441 Section UL 2703 mechanical • • 4,.� -- RD(rafter-or-deck)Structural Screw The RD tested and rated to compliance with 27"Rain Test"and and bonding QTriple Rated&Certified • Structural Screw anchors HUG to the root support 1004 (Ibs)of the International TAS 100 A -95 requirements. See to Respect the Roof" • c with an EPDM sealing washer,completing ( ) q Rev Descnpuon Date UL 2703 441(27) the stack of waterproofing barriers.See uplift and 368(Ibs) Building Code& "Wind Driven Rain Flush Mount Manual 0 INITIAL DESIGN 2/28/2025 Intertek TAS 100(A)-95 backside for more installation information. of lateral load. ASCE/SEI-7. Test"by Intertek. for more info. A B PROJECT# NA DATE DRAWN 2/28/2025 I I DRAWN BY ER SHEET# PV-7 4 TITLE ATTACHMENT SPEC 28357 Industrial Blvd. 28357 Industrial Blvd. RON RI DGE Hayward;CA 94545 1-800-227-9523 /X I R O N R I DG E Hayward,0 - 95 93 IronRidge.com IronRidge.com Attn:Corey Geiger,COO,IronRidge Inc The parameters and adjustments allowed in the span tables are defined as the following: Date:September Pin.2021 1. The Flush Mount System is designed as a Risk Category II structure as defined by ASCE 7-16 Table 1_5-1. THESE DRAWINGS ARE SUBJECT TO COPYRIGHT Re:Structural Certification and Span Tables for the IronRidge Flush Mount System PROTECTION BY US LAW.REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT 2 Wind speed shall conform to ASCE 7-16 Fig_26 5-1 B(for Risk Category II)and applicable state&local PRIOR WRITTEN APPROVAL FROM CURRENT This letter addresses the structural performance and code compliance of IronRidge's Flush Mount System. The county/city amendments to the IBC. No special wind topographic features are included and both topographic RENEWABLES ENGINEERING INC contents of the letter shall be read in its entirety before applying to any project design.The Flush Mount System is a coefficient(K.,1)and wind ground elevation factor(Ke)are taken as 1 0 proprietary rooftop mounting system used to support photovoltaic(PV)modules installed in portrait or landscape Current 3. Snow load used in the span tables is the ground snow and shall conform to ASCE 7-16 Fig_72-1 and orientation and set parallel to the underlying roof surface. PV modules are supported by extruded aluminum XR Rails applicable state&local countyicity amendments to the IBC. If the local jurisdiction specified snow load is in the I and secured to the rails with IronRidge mounting clamps.The XR Rails are side mounted to a selected roof format of a flat roof snow.it shall first be converted to a ground snow following the local building code/ Er cl nee rirc attachment with 3/8'stainless steel bonding hardware and then attached directly to the roof structure or to a stanchion amendments before the application of the attached span tables. No special snow conditions are considered that is fastened to the underlying roof structure Assembly details of a typical Flush Mount installation and its core including unbalanced,drifting,sliding, retention,or ponding snow.No rain-on-snow surcharge load is CURRENT RENEWABLES ENGINEERING INC. considered.The span tables do not apply to buildings which are intentional) kept below freezin kept just 3600 Lime Streetmjec 2 Riverside r 92501 components are shown in Exhibit EX-0015. P PP Y 9 Y P 9 p 1 Email Pi°jects@crengsolar above freezing,or unheated. Websde —cren9 co PHONE:(951)-204-5492 The IronRidge Flush Mount System is designed and certified to the structural requirements of the reference standards 4 The span tables reflect the ASCE 7 prescribed earthquake loads with the maximum magnitudes being: CONTRACTOR INFO listed below.for the load conditions and configurations tabulated in the attached span tables. (a)For ground snow no greater than 42psf Ss<_2.Og for Site Class A,B,C.&D. • ASCE/SEI 7-16 Minimum Design Loads for Buildings and Other Structures(ASCE 7-16) (b)For ground snow greater than 65psf:Ss<_1.0g for Site Class A.B,C.&D. • 2018 International Building Code(IBC-2018) (c)For ground snow between 42 and 65psf:Ss<_1.5g for Site Class A. B,C.&D. El • 2020 Building Code of New York State(BCNYS-2020, Published in November 2019) EZSYSSU • 2015 Aluminum Design Manual(ADM-2015) 5. Roof zones are defined by ASCE 7-16 Figure 30.3-2A to Figure 30.3-21 and are organized into three groups in which the zones share the same External Pressure Coefficients(GCp). Roof zones comprising each group along ELEMENT ENERGY LLC. • Report SEAOC(Structural Engineer Association of Califomia)PV2-2017 Wind Design for Solar Arrays with each roof zone's size and location are depicted in Figures 2 and 3 below each span table. 7470 SOUND AVENUE,MATTITUCK, NEW YORK,11952 The tables included in this letter provide the maximum allowable spans of XR Rails in the Flush Mount System for 6. The maximum rail cantilever length,measured from the rail end to the nearest attachment point.shall PH:(631)7797993 services@e2sys.com the respective loads and configurations listed.covering wind exposure categories B,C, &D,roof zones provided in be the lesser of the following two conditions:40%of the allowable span provided for the respective load Licence-ME-52689 &configuration condition from the span tables,or 36". (MASTER ELECTRICIAN) ASCE 7-16 for gable&hip roof profiles. and roof slopes of 8`to 45°. The tabulated spans are applicable when the Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) following conditions are met: 7 Allowable span length in the charts may be multiplied by a factor of 1.08 if the rails are continuous over a minimum of three spans. STEVE STATHOUDAKIS 1. Span is the distance between two adjacent roof attachment points(measured at the center of the 8. No splices are allowed in the rail cantilever. For each XR splice type install per the following requirements: 280 THE SHORT LN, EAST attachment fastener). MARION, NY 11939 a) XR Bonded Splice cannot be installed in the center 1/3 of interior spans.or the outer 2/3 of end spans. 2. Each module shall be supported by 2 rails(2 rail system)or 3 rails(3 rail system). Spans are calculated b) BOSS Splice can be installed at any location within a span. AHJ TOWN OF SOUTHOLD based on 2 rail systems,and conservatively deemed acceptable for 3 rail systems. 9 Shaded cells of the span tables indicate conditions in which UFO Mid Clamp connection capacity is exceeded. If UTILITY PSEG LONG ISLAND 3. The underlying roof slope,measured between the roof surface and horizontal plane.Is 80 to 450. such conditions are encountered contact support@ironrdge com. PV SUMMARY SYSTEM SIZE(KWDC) STC 425 X 35 =14.875 4 The mean roof height,defined as the average of the roof eave height and the roof ridge height measured PTC 398.1 1 X 1351 113.934 from grade,does not exceed 30 feet. SYSTEM SIZE (KWAC) 11.20 @240 MODULES 35 JINKO SOLAR 5. A clearance from the underside of the array to the roof surface of 2"minimum shall be provided and the ENPHASE 54HL4-B height of the array.the distance from the module top surface to the roof surface(defined as h2),shall not MICROINVERTER 35 Io8MC-72-M-US exceed 10". 6. Module length and area shall not exceed the maximum values listed on the respective span tables. 7 All Flush Mount components shall be installed in a professional workmanlike manner per IronRidge's Flush Rev Description Date Mount Installation Manual and other applicable standards for the general roof construction practice. 0 INITIAL DESIGN 2I28I2025 A B C 2021 IronRidge.Inc NY Flush Mount System Certificaton Letter-1 C 2021 Iron ldge.Inc NY Flush Mount System Certification Letter-2 PROJECT# NA DATE DRAWN 2/28/2025 DRAWN BY ER SHEET# PV-7.5 TITLE CERTIFICATION 213357 Industrial Blvd. 28357 Industrial Blvd. Hayward,CA 94545 Hayward,CA 94545 27-9523 IRONRIDGE I1-800-227-9523 IRONRIDGE IronRidge IronRidge.com IronRidge com 10. Systems using CAMO module clamps shall be installed with the following guidance: a) For single module installations(orphan modules)using modules with a length greater than 67.5", CAMO The span tables provided in this letter are certified based on the structural performance of IronRidge XR Rails only with no consideration of the structural adequacy of the chosen roof attachments, PV modules,or the underlying roof supporting clamps shall not be installed in regions that experience ground snow loads of 70psf and greater Such THESE DRAWINGS ARE SUBJECT TO COPYRIGHT scenarios are shown by asterisks in the applicable span tables. members. It is the responsibility of the installer or system designer to verify the structural capacity and adequacy of the PROTECTION BY US LAW REPRODUCTION IN aforementioned system components in regards to the applied or resultant loads of an chosen array configuration ANY FORM I EXPRESSLY FORBIDDEN CURREWITHOUNT b) CAMO will function within a modules design load ratings.Be sure the specific module being used with y p g pp y y g PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLEs ENGINEERING INC CAMO meets the dimensional requirements shown in the figure below and that the module selected is suitable for the environmental conditions of a particular project. ��` 2 0 2 1 0 C1 0 7 Current Sincerely, r Na X� • j • *C2 �"` - Renewable' n�oa:21e Glass/Ceps ' _ 7 �� W 15:45: 1fJ S Engineering t. r a eu dry p CURRENT meNEWeBgESENGINEERINOGINC. OAS�'r 79 4i� 0 7 00 Email.Projects@creng.solar ROFESSIpa�\ V*tI www creng co Frame Compa?bFty: PHONE.(951)-204-5492 X=12-2.2mm Y=15-40 min CONTRACTOR INFO Gang Xuan,PE y - Senior Structural Engineer Figure 1.CAMO Module Frame Dimensional Requirements EZSYSV Span values for Exposed and Edge module conditions, as defined below, are included in the attached span tables and shall be used when each condition exists. The maximum allowable span for Exposed or Edge 7470ELEMENT ENERGY-I-C.SOUND AVENUE,MATTITUCK, v modules shall be the lesser of the following two: (1)The span value for the Exposed or Edge module condition: HH.( P631)77 11952 779 7993 (2)The span value determined by site wind speed and ground snow load.Additionally, irrespective of the lesser services@ersys com Licence- span,the shaded cells for the Exposed and Edge module conditions which reflect the UFO clamp usage (MASTER ELECTRICIAN) limitation detailed in note 9 of page 2 shall apply to the respective condition. Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) 1. Exposed Module conditions: STEVE STATHOUDAKIS 280 THE SHORT LN, EAST A module is defined as Exposed(per Section 29.4.4 of ASCE 7-16)if the distance from any of its free MARION, NY 11939 edges(an edge with no connectivity to other modules)to its facing roof edge(such as eave,ridge, rake,or AHJ TOWN OF SOUTHOLD hip)is greater than 0.5h(h is ASCE defined building height)AND if the distance from Its free edge to any other adjacent array or panel is greater than 4 feet. UTILITY PSEG LONG ISLAND The allowable spans and cantilever shall only be applied to the portion of rail directly under Exposed PV SUMMARY Modules. SYSTEM SIZE STC 425 X 35 =14 875 KWDC) PTC 398.1 X 35 =13.934 SYSTEM SIZE 11 20 @240 (KWAC) 2. Edge Module conditions: MODULES 35 11N KO SOLAR 1KM425N-54HL4-B ENPHAE A module is defined as an Edge Module when its distance from any side of the module to its facing MICROINVERTER 35 Q8MC5 2-M-US perimeter roof edge(such as eave, ridge,rake, or hip)is less than 2 times the height of the array(2h-) where h2 is measured from the roof surface to the top surface of the module The allowable spans and cantilever shall only be applied to the portion of rail directly under Edge Modules. Additionally, if the roof edge is the eave or ridge,only the rail nearest to that roof edge shall be considered for this span adjustment. Description Date rA INITIAL DESIGN 2/2 812 02 5 L 2021 IronRidge.Inc NY Flush Mount System Certification Letter-3 2021 IronRidge.Inc NY Flush Mount System Certification Letter-4 PROJECT# NA DATE DRAWN 2/28/2025 DRAWN BY ER I SHEET# PV-7 6 TITLE CERTIFICATION