Loading...
HomeMy WebLinkAbout51710-Z ho�a.oF sooryo�o Town of Southold * * P.O. Box 1179 53095 Main Rd °�y�oorsY a Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 46296 Date: 07/07/2025 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 15925 Route 25 East Marion, NY 11939 Sec/Block/Lot: 23.-1-11.3 Conforms substantially to the Application for Building Permit heretofore,filed in this office dated: 01/24/2025 Pursuant to which Building Permit No. 51710 and dated: 03/05/2025 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: Roof mounted solar panels to existing single-family dwelling as applied for. The certificate is issued to: Joyce Orrigo Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: 51710 6/10/2025 PLUMBERS CERTIFICATION: woo A tho 'Ue Signature ho��oFsa�ryo� TOWN OF SOUTHOLD BUILDING DEPARTMENT • you TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 51710 Date: 03/05/2025 Permission is hereby granted to: Joyce A Orrigo 130 Stanley Dr Centereach, NY 11720 To: install roof-mounted solar panels to existing single-family dwelling as applied for. Premises Located at: 15925 Route 25, East Marion, NY 11939 SCTM#23.-1-11.3 Pursuant to application dated 01/24/2025 and approved by the Building Inspector. To expire on 03/05/2027. Contractors: Required Inspections: Fees: SOLAR PANELS $100.00 ELECTRIC.-Residential $125.00 CO-RESIDENTIAL $100.00 Total S325.00 --- --- ------------------- uilding Inspector SO(/j�o Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 • Q Southold,NY 11971-0959 BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Joyce A Orrigo Address: 15925 Route 25 City: East Marion St: NY Zip: 11939 Building Permit#: 51710 Section: 23 Block: 1 Lot: 11.3 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: Leviathan Solar License No: 66039ME SITE DETAILS Office Use Only Indoor F Basement P7 Service F. Solar W Outdoor W 1 st Floor Pool (- Spa F Renovation (— 2nd Floor Hot Tub r Generator Survey N Roof 170 Garage Battery Storage F INVENTORY Service 1.ph (— Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph r Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures Other Equipment: 4.6kW Roof Mounted PV Solar Energy System w/ (10)REC460AApureRX Modules, Combiner Panel w/ (1)220A (1)215A Braeker, On Backfed 30A Breaker Notes: Solar Inspector Signature: X Date: June 10, 2025 Sean Devlin Electrical Inspector sean.devlin(aD-town.southold.ny.us 15925MainRdSolar OE SOUTyO� 7*. TOWN( OF SOUTHOLD BUILDING DEPT. "cou ,N 631-765-1802 1-NS-PECTION [ ] FOUNDATION 1ST/REBAR [ ] ROUGH. PLBG. [, ] FOUNDATION 2ND [ ] INSULATION/CAULKING- [ ] ,FRAMING /STRAPPING [ ] FINAL 11 FIREPLACE & CHIMNEY [ ] FIRE'SAFETY INSPECTION [ ] -FIRE RESISTANT CONSTRUCTION, [ .] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ]. PRE C/O [ ] RENTAL REMARKS: L ehA —)-7/T4- 1,7ofr) bl'A_ _4�A± p %.- L/N., ' I �. m, Q1 - o , DATE INSPECTOR (O �o�aOE SOUlyO� ` TOWN,OF SOUTHOLD BUILDING DEPT �o�y�OUNi�Oio 631-765-1802 INSPECTION [ ] FOUNDATION 1 ST/ REBAR [ ]- ROUGH PLBG. ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION f ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION - [ - ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ - ]. RENTAL REMARKS:, c"AAcla DATE INSPECTOR �# ,51 -1 o J A M E S J. S TOUT A RCHITECT & Assoc. 2 G REG L ANE E AST NORTHP0R TN. Y. 631 - 8 58 9388 Post Install Letter June 12,2025 RE: Orrigo Residence 15925 Main Road East Marion, NY 11939 Permit 228512 To Whom it may concern: This letter is to confirm that as of this date, June 12, 2025, I, James J Stout, NYS license 021633 have visually inspected the placement and installation of the roof top solar panels at the above listed address. The solar panels have been installed as per manufacturers' guidelines and specifications. The .racking system design and installation complies with all applicable codes. The installation was done as per the approved Building Department plans. The analysis of the documents supplied by the client relies on sound engineering judgment and relevant experience. However, regardless of the professional's qualifications or thoroughness of the investigation, preexisting _conditions cannot always be anticipated beyond the scope of direct observation. No additional guarantees, whether expressed or implied, are provided regarding the professionals' recommendations outlined in this letter. This certification letter must be presented to the municipality within 120 days of the issuance date to ensure compliance with safety procedures and continuity of service. Thank you for your cooperation in this matter. James J. Stout �RED ARC �21 N 33 oQ J U N 1 2 2025 TF EB y Lkumfing Department LI 'Town of southoid FIELD INSPECTION REPORT DATE COMMENTS FOUNDATION (IST) ------------------ ------------------- FOUNDATION (2ND) ROUGH FRAMING& PLUMBING INSULATION PER N.Y. STATE ENERGY CODE 412- FINAL ADDITIONAL COMMENTS 9 - 6-- 215 -PqZd- Z576-0 vle-c-4- 14 f? Ca 0 =o�gUfFOtK��G TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 y. x Telephone (631) 765-1802 Fax (631) 765-9502 htti)s://www.southoldtomDu.go_v Date Received APPLICATION FOR BUILDING PERMIT .I' For Office Use Only ^ ' PERMIT NO. 5 Building Inspector: f JAN 2 4 2025 I Applications.and forms must be filled out in their entirety.Incomplete G=1sv'�''s1 `•��' • >'"�s applications will not be accepted. Where the Applicant is not the owner,an Owner's Authorization form(Page 2)shall be completed. Date: I 1 O aaa� OWNER(S)OF PROPERTY: Name: SC TM#1000- CQ'3,(DC) p).o0— c51I. vo3 Project Addre Phone#: Email: Mailing Address: CONTACT PERSON: ; Name:-,.� _ rU41t Aon..._...__w_... _. Mailing Address: Phone#:�31 —S _ a��, e�c�( f I t Email: �jr �lon�1�,�icy-4'�r�gnsD�ctc(�r� DESIGN PROFESSIONAL INFORMATION: Mailing Address:C _ Phone#:(�,31-$,g-y_c13Sq Email:SA-p,rv,Q%o a��(o�rneSslo ��rt�, .cam,c% CONTRACTOR INFORMATION: Name: L.Rc-.__ . _... _ Mailing Address:` q3.__ P6�� Roc�ZLon` oiY1 p• -__.'1\ll.� Phone#tD_? 53z'o .3�- _ Email:,prGt_r1G�61 i c�Si)�0.c C os� DESCRIPTION.OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition []Alteration ❑Repair ❑Demolition CDQ_.(` Estimated Cost of Project: %!Other 1S0.:C)0Will the lot be re-graded? ❑Yes E�Rlo Will excess fill be removed from premises? ❑Yes Flo 1 r PROPERTY,INFORMATION, . = Existing use of property: S% -4z_ 4az<A Intended use of property:sC)V3Lc' (� S Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes ❑No IF YES, PROVIDE A COPY. Check,BOX After Reading -The owner/contractor/design professional is,responsible for all drainage and storm water,issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for,the issuance of a Building Permit pursuant to the Building Zone ' Ordinance of the Town of Southold,'Suffolk,County;New York and otherapplimble Laws;Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to,comply with all applicable laws,ordinances;building code, housing code and regulations and to admitauthorized inspectors on premises and in buildings)for.'necessary inspections.False statements made herein are punishable:as a Class A misdemeanor pursuant tocSection 210.45 of the New York State Penal Law: Application Submitted By(print name): ►uthorized Agent ❑Owner Signature of Applicant Date: STATE OF NEW YORK) SS: COUNTY OF GI 1o�Uh ��il�YO being duly sworn, deposes and says that (s)he is the applicant (Name of individual signing contract) above named, (S)he is the (Contractor,Agent, Corporate Officer, etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this day of 20a� i OF NE9N(ti'OtI<�0 Nota — NOTARY 9PUBLIC i = ® ,od in SUFFOLK CoWy� 01 MOOOD8090 d CU PROPERTY OWNER AUTHORIZATION ,,�s�, ;X `��` (Where the applicant is not the owner) ����r�lll►����� � residing at� qaa — ma,-lC) C� c) do hereby authorize cG �CJLG<N\ ��YY�7�'e to apply on my behaA to the Town of Southold Building Department for approval as described herein. wn r' Ign re Date Print Owner' ame 2 5ti;��S�FFO(,�co. BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD a Town Hall Annex- 54375 Main Road - PO Box 1179 o ® Southold, New York 11971-0959 4, o� Telephone (631) 765-1802 - FAX (631) 765-9502 lamesh(cDsoutholdtownny.gov — sea nclC@southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Company Name: Electrician's Name: o License No.: MF _C ��t Elec. email: JZ)(-crdv 1ej; _Vk-)c;.nSct r. �A Elec. Phone No: I request an email copy of Certificate of Compliance Elec. Address.: I c+G 3 Pow JOB SITE INFORMATION (All Information Required) Name: C Address: Cross Street: Phone No.: Bldg.Permit#: S 1 -7 1 0 email: Tax Map District: 1000 Section: O-Z3 Block: t .co Lot: /1, c;•u ' BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): y.(a K)J 10 panel S 16M1erainver4e`S Square Footage: Circle All That Apply: Is job ready for inspection?: YES E] NO Rough In Final Do you need a Temp Certificate?: YES NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# ❑New ServiceQFire ReconnectOFlood ReconnectOService Reconnect QUndergroundQOverhead # Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: inSpec\­rm cc- PAYMENT DUE WITH APPLICATION C�. BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD � Town Hall Annex - 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 4- �o Telephone (631) 765-1802 - FAX (631) 765-9502 1 iamesh ansoutholdtownny gov sea nd chi southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Company Name: (' Electrician's Name: �o License No.: ME-(c(,C)��q Elec. email: b(-c �dU I��J: h c�nSo� r•. Elec. Phone No: L3j_ 5_53- Z jn.l request an email copy of Certificate of Compliance Elec, Address.: 1443 Roy. ' JOB SITE INFORMATION (All Information Required) Name: 'C, Q Address: sc, Cross Street: Phone No.: Bldg.Permit #; 51 -7 10 email: Tax Map District: 1000 Section: c2.3 Block: l .c%3 Lot: II. cam, BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please. Print Clearly): L4.(o KN4 JU PC,ne M; ccc/'nver-4e,S Square Footage: Circle All That Apply: Is job ready for inspection?: YES NO Rough In Final Do you need a Temp Certificate?: YES NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# New Service❑Fire Reconnect[]Flood Reconnect Service Reconnect[]Underground[]Overhead # Underground Laterals D 1 2 H Frame Pole Work done on Service? Y MN Additional Information: 1n.Spec.\rcS1 cc-' = ROr q, itv ,s�` c- pE'S os , Ov� -,S3\cs- C1E04t`C� ` • PAYMENT DUE WITH APPLICATION 0 PERMIT# J�"/ '7 ! (� Address: Switches Outlets G FI's Surface Sconces H H's UC Lts Fridge HW POOL Fans Mini Fr. W/D PanelPump Exhaust Oven Sump Heater Trnsfmr Smokes DW Generator Salt Gen. Carbon Micro GrbDis Water Bond Lights Heat Pucks ERV HOT TUB/SPA Inst Hot DeHum Transfer Disc Combo Cooktop Minisplit Blower AC AH Hood Blower Service Amps Have Used Sub Amps Have Used Comments �a APP VED AS NOTED DATE•3 B.P.# FEE BY: NOTIFY BUILDING DEPARTMENT AT 631-765-1802 8AM TO 4PM FOR THE FOLLOWING INSPECTIONS: 1. FOUNDATION-TWO REQUIRED FOR POURED CONCRETE 2. ROUGH-FRA10ING& PLUMBING 3. INSULATION 4. FINAL-CONSTRUCTION MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTON ERRORS ELECTRICAL INSPECTION REQUIRED COMPLY WITH ALL CODES OF NEW YORK STATE&TOWN CODES AS REQUIRED AND CONDITIONS OF SOLD WN ZBA SOLITHO OWN PLANNING BOARD SOUTH0 TOWN TRUSTEES N,Y,S, C SO OLD HPC SD OCCUPANCY OR USE IS UNLAWFUL WITHOUT CERTIFICATI� OF OCCUPANCY III III III III! III I J AMES J. S TOUT A RCHITECT & Assoc. 2 G REG LANE EAST NORTHPORT N. Y. 631 - 8 58 9388 Letter of Certification January 10, 2025 Re: Orrigo Residence 15925 Main Road East Marion, NY 11939 To Whom it may concern: I, James J. Stout, registered architect NYS license number 021633 would like to submit the following. I have inspected and analyzed the roof structure at the above listed address and have determined the structure and the attachment to be adequate to support the new additional load imposed by the proposed solar system and complies with the 140-mph wind design load as per 2020 Residential code of NYS (RCNYS), 2020 Energy conservation construction code of NYS (ECCCNYS), and the ASCE 7-16. The existing 2"x 10" @ 16"o.c. roof rafters have been analyzed and will provide adequate support. Thank you for your understanding in this matter. Sincerely, James J. Stout EKED Aqc rF 21 3�yoQ NE LBT: 4 I. I,5#3otDu C 1 Lon: -72.321574PHOTOVOLTAIC ROOF MOUNT SYSTEM I 10 REC460AA Pure-RX MODULES ROOF-MOUNTED - 4.600 kWDC / 3.800 kWAC 15925 Main Road , East Marion , NY 11939 APPLICABLE CODES, LAWS AND PROJECT LOCATION SHEET INDEX REGULATIONS & VICINITY MAP LEVIATHAN SOLAR INC 1993 Pond Rd, Ronkonkoma, NY 1177 Cl- COVER SHEET 2020 NEC ; `'f '? +1 631-553-2732 : info@leviathansolar.com R1- SOLAR LAYOUT AND ROOF INFO. 2020 BUILDING CODE OF NYS 'f,.- •� ':' •�' ; H 1-65859 2020 RESIDENTIAL CODE OF NYS R2- PLOT SURVEY PAGE. ' 6 L 4 2020 EXISTING BUILDING CODE OF NYS 2020 FIRE y 1 +s �''' ~tw s TITLE: R3- ROOF PLAN WITH MODULES. r N CODE OF NYS ._ : ''t f�. COVER SHEET •+r.�' •;":' '�_ `�. • R4- RAFTER VIEW, MOUNTING DETAILS & BOM. 2020 PLUMBING CODE OF NYS 't; '. c: PARCEL ID: 1000-023.00-01.00-011.00" El 3-LINE DIAGRAM. 2020 MECHANICAL CODE OF NYS M ,fr, �1► �, �rj�., • '' CUSTOMER NAME: P1- PLACARD BREAKDOWN. GENERAL NOTES. .`4` ~ '� Joyce Orrigo S1- EQUIPMENT SPEC SHEETS. 1. SOLAR PANELS WILL BE 10 (REC460AA Pure-RX) WITH AN CUSTOMER ADRRESS. OUTPUT OF 4.600 kWDC AND 10 (IQ8X-80-M-US) ' - ; ?f,'i 15925 Main Road S2- EQUIPMENT SPEC SHEETS. MICROINVERTERS. %K . East Marlon, NY 11939 2. INSTALLATION IN ACCORDANCE WITH MANUFACTURER S3- EQUIPMENT SPEC SHEETS. RECOMMENDATIONS. AHJ: 3. ENGINEER TO INSPECT PROJECT AFTER INSTALLATION AND S4- EQUIPMENT SPEC SHEETS. CERTIFY COMPLIANCE. �, t , � Town Southold 4. PROJECT TO BE INSTALLED WITH CODE COMPLIANT + t • " �' UTTILITY: STAMP & COMMENTS. RACKING INSTRUCTIONS FOR SNAPNRACK SOLAR MOUNT { ;• '�4' PSEGLI SYSTEM. DATE: 12/20/2024 5. FOLLOW BALLASTING SCHEDULE ON ROOF PLAN. 6. THE SOLAR INSTALLATION CONTRACTOR, COMPLIES WITH DRAWN BY: ALL LICENSING &ALL RELATED REQUIREMENTS OF THE GOVERNING MUNICIPALITIES AND THE LOCAL ELECTRIC FELIX GONZALEZ UTILITY AHJ'S. Felix@leviathansolar.com 7. THIS PROJECT WILL COMPLY WITH THE CURRENT NEC +1 809-703-7147 REQUIREMENTS INCLUDING ARTICLE 690 SOLAR PHOTOVOLTAIC PV SYSTEMS. 8. THE ROOF WILL HAVE NO MORE THAN A SINGLE LAYER OF PLANS REVISIONS ROOF COVERING IN ADDITION TO THE SOLAR EQUIPMENT. 9. INSTALLATION WILL BE FLUSH-MOUNTED, PARALLEL TO AND 1 --/--/-- NO MORE THAN 6.5"ABOVE ROOF 10. MAINTAIN A MINIMUM OF 18" CLEARANCE AT RIDGE AND AT 2 --/--/-- ONE GABLE EAVE. 15925 Main Rd,East 11. THIS DESIGN COMPLIES WITH 140 MPH WIND Marion, NY 11939 REQUIREMENTS OF THE RESIDENTIAL CODE OF N.Y.S AND d ASCE 7-16. Dam Pond 12. WHEREVER THE ROOF PLAN DOES NOT COMPLY WITH ACCESS AND VENTILATION REQUIREMENTS OF THE UNIFORM tEPED ` c ' CODE, LEVIATHAN SOLAR PROPOSES THAT ALTERNATIVE VENTILATION METHODS WILL BE EMPLOYED. REVIEW AND APPROVAL SHALL BE AT THE DISCRETION OF THE * ,;� • - _1' MUNICIPALITY IN WHICH THIS DOCUMENT HAS BEEN FILED. 13. THE DESIGN PLANS COMPLY WITH THE 2020 NEW YORK ''F 2 6-3E '�� STATE UNIFORM FIRE PREVENTION AND RESIDENTIAL BUILDING CODE LEGEND Lat: 41.136866 R 1 -'; SOLAR MODULE: UTILITY METER Lon: -72.321574 ��1 18"RIDGE 36"ROOF ACCESS 36"GROUND AC MAIN SERVICE SETBACK SETBACK ACCESS ., i REC460AA Pure-RX METER#:\PXQC;98309652 AC MSP �E ENVOY 68.1"x48" ACC#:1PXQC;9684010802 DISCONNECT PANEL 36" ROOF ACCESS 36" GROUND ACCESS E LEVIATHAN SOLAR INC 1993 Pond Rd, Ronkonkoma, NY 1177 +1 631-553-2732 VENT info@leviathansolar.com PIPE HI-65859 TITLE: Q SOLAR LAYOUT & (N) ENVOY m ROOF INFO. (N)AC DISCONNECT UTILITY METER CUSTOMER NAME: MAIN SERVICE PANEL Joyce Orrigo SKYLIGHT CUSTOMER ADRRESS: CHIMNEY 15925 Main Road East Marion, NY 11939 AHJ: 36" GROUND AccEss Town Of Southold UTILITY: PSEGLI 36" ROOF DATE: 12/20/2024 ACCESS DECK DRAWN BY: FELIX GONZALEZ Felix@leviathansolar.com +1 809-703-7147 PLANS REVISIONS ti 2 DRIVEWAY Joyce Orrigo Eo aR 15925 Main Road `�P c 10 PANELS 15925 MAIN ROAD r r7 a7183� r0Q ( / TF OF NEB V LtUtNU 966 Lai: 41. 10130`3 H ) SOLAR MODULE: UTILITY METER Lon: -72.321574 L 18"RIDGE 36"ROOF ACCESS 36"GROUND �AC MAIN SERVICE ENVOY SETBACK SETBACK ACCESS REC460AA Pure-RX p�CC#:PXQQ 6840/0802 NECT MSP PANEL - 68.1"x48" L���J pi LEVIATHAN SOLAR INC 1993 Pond Rd, Ronkonkoma, NY 1177 +1 631-553-2732 info@leviathansolar.com 161 -11" H I-65859 � TITLE: 1 PLOT SURVEY PAGE 4 CUSTOMER NAME. Joyce Orrigo a1 CUSTOMER ADRRESS: 15925 Main Road East Marion, NY 11939 AHJ: Town Of Southold �S UTILITY: PSEGLI DATE: 12/20/2024 DRAWN BY: FELIX GONZALEZ Felix@leviathansolar.com 26 '-9" +1 809-703-7147 PLANS REVISIONS N 2 --/--/-- �0 cLel)ARC ' r 021 54t OP 'rF OF NE N S Lat: 41.136866 R4_ Lon. -72.321574 2"x10" RAFTERS @ 16" O.C. (TYP.) r REC460AA Pure-RX SOLAR PANELS „ LEVIATHAN SOLAR INC 1993 Pond Rd, Ronkonkoma, NY 1177 +1 631-553-2732 24' info@leviathansolar.com H I-65859 TITLE: RAFTER VIEW, MOUNTING DETAILS & BOM SPAN: CUSTOMER NAME: 12'-7" Joyce Orrigo ROOF CROSS SECTION RAFTER VIEW CUSTOMERADRRESS: 15925 Main Road N .T.S East Marion, NY 11939 AHJ: Town Of Southold UTILITY: PSEGLI DATE: 12/20/2024 BOM DRAWN BY: MID CLAMP� SNAP N RACK UR-40 RAIL FELIX GONZALEZ Felix@leviathansolar.com 7��J ^O FT _ PV MODULE PV MODULE +1 809-703-7147 � O PCS � ` SNAP N RACK 6 PCS SNAP N RACK j UR-40 RAIL UR-40 SPLICE PLANS REVISIONS N COMPOSITION SHINGLES SPEEDSEAL FOOT 26 PCS 14 PCS 5/16"X 4"LG.S.S.LAG BOLT SNAP N RACK WITSNAP N RACK z TYPHPRE-DRIS PRE-DRILL REQUIRED. �P�O�C r SPEEDSEAL FOOT MID CLAMP N CIO (E)RAFTER 4Q�r S w ;r u 0.75"MIN. Qt !1r�021t-3 A 12 PCS i 14 PCS SNAP N RACK ROOF ATTACHMENT DETAILS °F%E'o SNAP N RACK HARDWARE: SPEED SEAL FOOT END CAP GROUND LUG Lai: 41.1 6btibb ' ] Lon: -72.321574 r A,WARNING 1 SOLAR PV SYSTEM RAPID POWER SOURCE SWITCH FCR OUTPUT CONNECTION - EQUIPPED WITH i DO NOT RELOCATE THIS OVERCURRENT DEVICE DSHUTDOWN LABEL LOCATION: LABEL LOCATION: SUB PANEL (AC DISCONNECT) & UTILITY METER SUB PANEL (AC DISCONNECT) LEVIATHAN SOLAR INC 1993 Pond Rd, Ronkonkoma, NY 1177 PV SYSTEM DISCONNECT SOLAR ELECTR C @ viatha3 2732 infoleviathansolar.com PHOTOVOLTAIC , • • A PV PANELS HI-65859 ,WARNING ELECTRIC SHOCK HAZARD A AC DISCONNECT A TERMINALS ON THE LINE TITLE: AND LOAD SIDES RATED AC OUTPUT CURRENT 15.80 A PLACARD BREAKDOWN MAY BE ENERGIZED NOMINAL OPERATING AC VOLTAGE 240 V TURN RAPID SHUTDOWN SWITCH TO IN THE OPEN POSITION P"a,Mn "2'' CUSTOMER NAME: THE OFF POSITION TO SHUT DOWN Joyce Orrigo LABEL LOCATION: LABEL LOCATION: CUSTOMER ADRRESS: SUB PANEL (AC DISCONNECT) & MAIN SERVICE PANEL MAIN SERVICE PANEL & SUB PANEL (AC DISCONNECT) PV SYSTEM AND REDUCE _ 15925 Main Road SHOCK HAZARD IN THE ARRAY " East Marion, NY 11939 A WARNING AHJ: LABEL LOCATION: Town Of Southold SUB PANEL (AC DISCONNECT) UTILITY: DUAL POWER SUPPLY . PSEGLI � SOURCES: UTILITY GRID AND SOLALINE SIDE TAP F I CONNECTION DATE: 12/20/2024 PV SOLAR ELECTRIC SYSTEM i DRAWN BY: FELIX GONZALEZ LABEL LOCATION: LABEL LOCATION: Felix@leviathansolar.com MAIN SERVICE PANEL & UTILITY METER MAIN SERVICE PANEL +1 809-703-7147 (N)ENVOY (N)AC DISCONNECT UTILITY METER—[ - MAINSERVICEPANEL ® PLANS REVISIONS WARNING P ` I DECK TURN OFF PHOTOVOLTAIC WARNING AC DISCONNECT PRIOR TO WORKING INSIDE PANEL PHOTOVOLTAIC POWER SOURCE I �It LABEL LOCATION: LABEL LOCATION: Joyce Orrigo DRIVEWAY —------ '� 4 ,> •L. � 1, JUNCTION BOXES & MAIN SERVICE PANEL CONDUIT&JUNCTION BOXES 15925 o A Main Road 15925 MAIN ROAD I - Lat: 41.136866 Lon: -72.321574�L-S 1 ALINHA° ��� RK SOLAR'S MOST TRUSTED RE C 6 SOLAR'S MOST TRUSTED DATASHEET 1)2flr25 MN1uNrrrtsMmm 1.. ® GENERAL DATA ea sib us REF ALPHA88 half-cut bifacial REC heterojunction cells. T--- - - - CeIlType with gaplesstechnology Glass 3.2 mm solar glass with anti-reflective surface treatment I a a in accordance with EN12150 PURE-RX 5ERIE5 FrameBacksheet Highly resistant polymer(Black) two Frame Anodized aluminum(Black) « Junction Box 4-part.4 bypass diodes. + IP68 rated,in accordance with lEC62790 a c f. Connectors Staubli MC4 PV-KBT4/KST4(4 mm') LEVIATHAN SOLAR INC n accordance with lEC62852,IP68 only when connected 1 1993 Pond Rd, Ronkonkoma, NY 1177 DATASHEET x I Cable 4 mm2 solar cable, 'p' +1 631-553-2732 in accordance with EN50618 �] Dimensions 1728x1205x30mm(2.08m2) 0sros\ info@leviathansolar.com Weight 22.7kg HI-65859 . , Origin Made in Singapore 45 2 5 5W t3 a; ELECTRICAL DATA PRODUCT CODE`:RECxxxAA Pure-RX CERTIFICATIONS � TITLE' Power Output-P_(Wo) 450 455 460 46S 470 IEC 61215:2021:IEC61730:2016;UL61730 r EQUIPMENT SPEC _r Watt Class Sorting-(W) 0/+5W 0/+SW O/+5W 0/+5W 0/+5W :EC IgnmoniaResiy(EN tanceICIassE) ; IEC 62716 Ammonia Resistance SHEETS . Nominal Power Voltage-VA1Pe(V) 54.3 54.6 54.9 55.2 55.4 IEC61701 SaltMlst(SM6) t : Nominal Power Current-I e,(A) 8.29 8.34 8.38 8.43 8.49 EC 61215 2016 Hailstone(35 mm)UL 61730 Fire Type 2 v CUSTOMER NAME: F Open Circuit Voltage-Va(V) 6S.1 65.2 65.3 65.5 65.6 ISO 14001;IS09001;IEC45001:IEC62941 Ln Joyce Orrigo Short Circuit Current-ISc(A) 8.81 8.84 8.88 8.91 8.95 0 Power Density(W/m') 216 219 221 224 226 v takef+waY _� CUSTOMER ADRRESS: Panel Efficiency(%) 21.6 2t9 22.1 22.3 22.6 °E ` n 15925 Main Road nK vcE�. East Marion, NY 11939 PowerOutput-Pmax(We) 343 346 350 354 358 Nominal Power Voltage-V_(V) 51.2 51.4 51.7 52.0 522 AHJ: Z Nominal Power Current-I_(A) 6.70 6.73 6.77 6.81 6.86 WARRANTY Open Circuit Voltage-Vnc(V) 61.3 61.5 61.6 61.7 61.8 Standard REC ProTrust Town Of Southold � � MODULE CURRENT Installed by d UTILITY: Short Circuit Current-I (A) 7.11 7.14 7.17 7.2 723 sc REC Certified No Yes Yes COMPATIBLEI Valuesatstandardtestcondr-,15TCdirmdssAM15.irradonce1000W/m',temperatme25•C).bawd or,aproductionspreadwithatoleranceofP__Vx&I,s3% Professional PSEGLI within one watt crass.Nominal module operating temperature iNMOT air mass AM 15ra.mdiance 800 W/m',tempera ture 20•C.windspeed 1 Ws).'Where...indicates the n°minalpore,cl-IP-)a,STCabnve System Size All <25kW 25-SOOkW Product Warranty zo zs zs DATE: 12/20/2024 MAXIMUM RATINGS* TEMPERATURE RATINGS* (yrs) Operational Temperature -40°C-85°C Power Warranty 25 25 25 P P NominalModuleOperating (yrs) DRAWN BY- System Voltage 1000 V 44°C 2°C g Temperature Labor Warranty 0 25 10 FELIX GONZALEZ Maximum Test Load(front) +7000 Pa(713 kg/m') (yrs) Temperature coefficient of PNe% -0.24%/°C Maximum Test Load(rear) -4000 Pa(407 kg Power in Year 1 98% 98% 98%/m2) v /Temperature coefficient o oc V -0.24% ° R C cD Felix@leviathansolar.com • . Max Series Fuse Rating 25 A Temperature coefficient of ISc 0.04% °C Annual Degradation 0.25% 0.25% 0.25% N 25 Max Reverse Current 25 A / +1 809-703-7147 #; •rnetemperatvrecnefecentatatedarehnear°awe: Power in Year 25 92% 92% 92% m 'See-nstallaton manual for mounurig�nstrucnoin. s o The REC ProTrust Warranty only available s•% - Design load-Test load/15(safety factor) e on panes purchased throw an REC Certified Solar Professional installer 5 DELIVERY INFORMATION conditions aPdY www See recgrouP com for morere details � } Panels per Pallet 33 o PLANS REVISIONS N Panels per 40 ft GP/high +.wt 'ea �+'• 594(18 Pallets) LOW LIGHT BEHAVIOUR to cube container o *° .� Panels per 13.6 m truck 660(20 Pallets) Typical low irradiance performance of module at STC: a 1 --/--/-- s ' Available from: w •- -- - Ac all - Founded in 1996,REC Group is an international pioneering solar energy company dedicated to empowering consumers with clean.affordable REC Solar PIrE.LTD. _ • .-•}K - � - P P 8 8Y P Y P°N' g n r - * solar power 20 Tuas South Ase.14 .As Solar's Most Trusted.REC is committed to high quality.innovation,and a low carbon footprint in the solar materials and solar I!1- e ' • - "w" .mow. �' panels it manufactures.Headquartered in Norway with operational headquarters in Singapore,REC also has regional hubs in North America, Singapore 637312 `1.` '\ Europe.and Asia-Pacific. post@recgroup.com jr• a �:,�. P' www recgroup.can r' U21 63� J�Q` NEB Lat: 41.131566b L-S Lon: -72.321574 ENPHASE CIMCM CIZIM IQ8X Microinverter INPUT,. . tDC1 Commonly used module pairings IN 320-540 _ Module compatibility To meet compatibility,PV modules must be within Max.Input DC voltage and Max module I listed below Module compatibility can be checked at https://eni)hase.com/installers/microinverters/calculator MPPT voltage range v 43-60 __w Operating range V 25-79.5 %F-1 Minimum and Maximum start voltage V 30-79.5 LEVIATHAN SOLAR INC \ Max.input DC voltage V 79.5 1993 Pond Rd, Ronkonkoma, NY 1177! J J Max.continuous operating DC current A 10 +1 631-553-2732 r info@leviathansolar.com - Max.input DC short-circuit current A 16 0 Max.module 1,, A 13 HI-65859 Overvoltage class DC port II DC port backfeed current mA 0 TITLE PV array configuration Ungrounded array:no additional DC side protection required;AC side protection requires max 20 A per branch circuit EQUIPMENT SPEC Peak output power VA 384 366 SHEETS Max.continuous output power VA 380 360 1 Q 8X Microinverter Nominal grid voltage(L-L) v 240,split-phase(L-L).180' 208.single-phase(L-L).120° CUSTOMER NAME: Minimum and Maximum grid voltage' V 211-264 183-229 Joyce Orrigo Our newest I08 Series Microinverters are the industr rid-forming*,software- Max.continuous output current A 1.58 1.73 y's first micro 9 g'' M tinos ot Easy to install P CUSTOMER ADRRESS: defined microinverters with split-phase power conversion capability to convert DC power to AC power efficiently.IQ8X Microinverter is the latest addition to this family,designed to support Lightweight and compact with plug- Nominal frequency Hz 60 15925 Main Road PV modules with higher input DC voltage and cell counts,such as 96 cells,80 half-cut cells, and-play connectors Extended frequency range Hz 47-68 and 88 half-cut cells.The brain of the semiconductor-based microinverter is our proprietary Power line communication(PLC) East Marion, NY 11939 between components application-specific integrated circuit(ASIC),which enables the microinverter to operate in AC short circuit fault current over three cycles Arms 2.70 grid-tied or off-grid modes.This chip is built in advanced 55 nm technology with high-speed Max.units per 20 A(L-L)branch circuit' 10 9 digital logic and has superfast response times to changing loads and rid events,alleviating Faster installation with simple two-wire 9 9 P P 9 9 9 9 AHJ: constraints on battery sizing for home energy systems. cabling Total harmonic distortion % <5 Overvoltage class AC port III Town Of Southold High productivity and reliability UTILITY: AC port backfeed current mA 18 Produces power even when the grid is PS E G L down' Power factor setting 1.0 • More than one million cumulative hours Grid-tied power factor(adjustable) 0.85 leading...0.85lagging DATE: 12/20/2024 Part of the Enphase Energy System, IQ8 Series Microinverters redefine of testing Peak efficiency % 97.6 97.4 IQ8 Series Microinverters integrate with reliability standards with more than one Class II double-insulated enclosure CEC weighted efficiency % 97.2 96.9 DRAWN BY'. the IQ Battery,IQ Gateway,and the million cumulative hours of power-on Optimized for the latest high-powered Enphase App monitoring and analysis testing,enabling an industry-leading Nighttime power consumption mw 22 29 F E L I X GO NZALEZ PV modules software. limited warranty of up to 25 years. MECHANICAL DATA Felix@leviathansolar.com Microgrid-forming Ambient temperature range -40`C to 55'C(-40°F to 149"F) +1 809-703-7147 Complies with the latest advanced grid Relative humidity range 4%to 100%(condensing) support DC connector type Staubli MC4 PLANS REVISIONS Remote automatic updates for the Dimensions(H x W x D);Weight 212 mm(8.3")x T75 mm(6.9")x 30.2 mm(1.2');1.1 kg(2.43 Ibs) latest grid requirements Connect PV modules quickly and easily IQ8 Series Microinverters are UL listed Configurable to support a wide range Cooling Natural convection-no fans 1 to the IQ8 Series Microinverters that have as PV rapid shutdown equipment and of grid profiles Approved for wet locations:pollution degree yes:PD3 integrated MC4 connectors. conform with various regulations when Meets CA Rule 21(UL 1741-SA)and IEEE Enclosure Class II double-insulated,corrosion-resistant polymeric enclosure 2 installed according to the manufacturer's 1547:2018(UL 1741-SB) instructions. Environ.category;UV exposure rating NEMA Type 6;outdoor COMPLIANCE Note: I08 Series Microinverters cannot be nixed together CA Rule 21(UL 1741-SA),UL 62109-1.IEEE 1547:2018(UL 1741-SB).FCC Part 15 Class B,ICES-0003 Class B,CAN/CSA-C22.2 NO.107.1-01 •Only when installed with 10 System Controller 2.meets UL 1741. with previous generations of Enphase microinverters Certifications This product is UL Listed as PV rapid shutdown equipment and conforms with NEC 2014.NEC 2017.and NEC 2020 section 690.12 and C22.1-2018 007 Series.106 Series.and so on)in the same system. Rule 64-218 rapid shutdown of PV systems for AC and DC conductors when installed according to the manufacturer's instructions. (1)No enforced DC/AC ratio. �{cPED "C —- (2)Nominal voltage range can be extended beyond nominal if required by the utility. 0 2023 Enphase Energy.All rights reserved.Enphase,the a and CC logos.IQ and certain other marks listed at (3)Limits may vary.Refer to local requirements to define the number of micronverters per branch in your area. U' n https://enphase_com/trad__ema_rk-usage-guidelines ere trademarks of Enphase Energy.lnc.in the US erld other countries. Data subject to change. IOBx-MC4-DSH-00185-1.0-EN-US-2023-08-21 108x-MC4-DSH-00185-1.0-EN-US-2023-08-21 r t A 1r �?16}� yOQ F QF NE`11 Lat: 41.136866 [� Lon: -72.321574 J 2 Snap rack- UR-40 SnapNrack Ultra Rail System UR-60 A sleek, straightforward rail solution for mounting solar modules .. .- Rail Mounting Solutions features two Ultra Railgraphic - - rail . . provides . . . .. .. . .. . :. compatible modulewith all existing mounts, LEVIATHAN SOLAR INC The Entire System is a Snap to Install 1993 Pond Rd, Ronkonkoma, NY 1177! • New Ultra Rail Mounts include snap-in brackets +1 631-553-2732info@leviathansolar.com for attaching rail • Compatible with all the SnapNrack Mid Clamps _- HI-65859 and End Clamps customers love • Universal End Clamps and snap-in End Caps provide a clean look to the array edge TITLE: EQUIPMENT SPEC SHEETS Unparalleled Wire Management CUSTOMER NAME: • Open rail channel provides room for running Joyce Orrigo wires resulting in a long-lasting quality install CUSTOMER ADRRESS: JI • Industry best wire management offering 15925 Main Road includes Junction Boxes, Universal Wire East Marion, NY 11939 Clamps, MLPE Attachment Kits, and Conduit Clamps AHJ: • System is fully bonded and listed to UL 2703 Town Of Southold The Ultimate Value in Rooftop Solar Standard UTILITY: PSEGLI • DATE. 12/20/2024 Industry leading Wire Mounts available for all Heavy Duty UR-60 Rail DRAWN BY- Management S• • ns rootypes • UR-60 rail profile provides increased span capabilities for high wind speeds and snow FELIX GONZALEZ loads Felix@leviathansolar.com Single Tool Installation • SnapNrack Module • Taller, stronger rail profile includes profile- +1 809-703-7147 • ; • • specific rail splice and end cap • All existing mounts, module clamps, and PLANS REVISIONS are compatible with accessories are retained for the same great both rail profiles install experience 1 --/--/-- Quality. Innovative . Superior. RESOURCES snapnrack.com/resources optimizeEU DESIGN snapnrack.com/configurator SnapNrack Solar Mounting Solutions are engineered to WHERE TO BUY snapnrack.com/where-to-buy • • • �r 02163 � J�P F OF NE 1+ LEGEND Lcll. "' 1Jvvvv Lon: -72.321574 SOLAR MODULE: STRUCTURAL REC460AA PURE-RX ATTACHMENT RAIL 68.1"x48" eR" itr F 1 '-6" LEVIATHAN SOLAR INC 1993 Pond Rd, Ronkonkoma, NY 1177 +1 631-553-2732 1 '-511 info@leviathansolar.com -- HI-65859 2'-1off TITLE: SOLAR PLAN WITH 2'-1 011 MODULES oF 13'-511 p CUSTOMER NAME: 2'-1 0" Joyce Orrigo Ij CUSTOMER ADRRESS: _ 15925 Main Road 2'-1 „ East Marion, NY 11939 AHJ: Town Of Southold UTILITY: 4, PSEGLI DATE: 12/20/2024 1 '-4" '-411 1-4 1 DRAWN BY: FELIX GONZALEZ 511 22'-211 1 3'—g" Felix@leviathansolar.com 7147com SOLAR LAYOUT: THIS ROOF WILL HAVE 10 REC460AA PURE-RX 460 WATT PANELS WITH AN PLANS REVISIONS OUTPUT OF 4.600 KW AND 10 IQ8X-80-M-US MICRO INVERTERS. 1 Attachment MAX.Framing Type Framing Size O/C spacing MAX.Attachment MAX.overhang RAILS QTY. ATTACHMENT QTY. Root tilt Roof Azimuth Type 9 YP 9 P g Spacing g ROOF 1 80 FT/ 6 PCs OF 172" RAIL ROOF 1 : 24 PCS Roof 1 24' 236' SNAPNRACK WOOD RAFTER 2"X10" 16" 64" 17' �PE3 C � t - r >r7 021633 yCQ TF OF NEB SOLAR MODULE SPECIFICATIONS AMBIENT TEMPERTURE SPECIFICATIONS INVERTER SPECIFICATIONS C SERVICE INFO. Lat: 41.1 30t366 Lon: -72.321574 E 1 TEMPERATURE �— MANUFACTURER/MODEL# QUANTITY NOMINAL OUTPUT NOMINALOUTPUT UTILITY PROVIDER:PSEGLI MODEL# VMP IMP VOC ISC COEFFICIENT #OF MODULES CONDUCTOR CONDUCTOR VOLTAGE CURRENT OF Voc RECORD AMBIENT TEMP TEMPERATURE TEMPERATURE IQ8X-80-M-US 10 240 VAC 1.58A MAIN SERVICE VOLTAGE:240V REC460AA PURE-RX LOW TEMP (HIGH TEMP 2%) RATE(ON RATE(OFF MAIN SERVICE PANEL:200A (46oW) 41.8 9.45 48.7 10.07 -027%rC 10 ROOF) ROOF) MSP LOCATION: BASEMENT MODULE DIMENSION 68.1"L x 48 W x 1.26"D 15° 31° 190° 75° t SYSTEM SIZE:-10x 46OW=4.600 kWDC NOTE:1"PVC CONDUIT 10x 380W=3.800 kWAC RUN(718"ABOVE ROOF) v LEVIATHAN SOLAR INC 1993 Pond Rd. Ronkonkoma, NY 1177 +1 631-553-2732 info@leviathansolar.com UTILITY METER M H I-65859 98309652 10 MICRO-INVERTERS IN BRANCH CIRCUIT#1 CCOU ACCOU T NT#: 9684010802 (10)IQ8X-80-M-US TITLE: MICRO-INVERTERS(240V) ELECTRICAL 3-LINE (LOCATED UNDER EACH PANEL) — I AC DISCONNECT DIAGRAM ti I ti � ti I `--'�------- `--'�------------ ------ L 60A D CUSTOMER NAME. 15A LINE SIDE TAP Joyce Orrigo I (N)(ROOF)JUNCTION BOX _ CUSTOMER ADRRESS: ' (E)MAIN BREAKER 15925 Main Road 2a° (ice LOOA/2P,240V East Marion, NY 11939 — L2 L2 \ ° 1 I AHJ: Town Of Southold UTILITY: I PSEGLI {}....... ENVOY DATE. 12/20/2024 �- - DRAWN BY. A — EXISTING GROUNDING FELIX GONZALEZ SYSTEM Felix@leviathansolar.com +1 809-703-7147 PLANS REVISIONS CONDUCTOR SCHEDULE AND CALCULATIONS Wire Temp. Wire Temp. Conduit Derated Inverter NEC Design Ground Ground Wire Wire Tag Conduit Gauge wire Type Rating Ampacity(A) Derate RII Derate Ampacity(A) Qty NOC(A) Correction Current(A) Size Type ED c A OPEN AIR 12 AWG Q Cable 75"C 30 0.94 1.0 28.80 10 1.58 1.25 19.75000A 06 AWG BARE CU �r a B 1"PVC 10 AWG THWN-2 75'C 40 0.94 0.80 30.72 10 158 1.25 i9.75000A 10 AWG THWN-2 r -- —- - - - 1l 02163" y0P C V PVC 10 AWG THWN 75°C 35 0.94 1.0 32.90 N/A 1.58 1.25 N/A 10 AWG THWN F OF NV'o D 1"PVC 6 AWG THWN 75"C 65 0.94 1.0 61.1 10 1.58 1.25 19.75000A 06 AWG THWN PHOTOVOLTAIC ROOF MOUNT SYSTEM Lat: 41.136866 Lon:-72.321574 C 1 .w- 10 REC460AA Pure-RX MODULES ROOF-MOUNTED - 4.600 kWDC / 3.800 kWAC 15925 Main Road, East Marion, NY 11939 APPLICABLE CODES, LAWS AND PROJECT LOCATION SHEET INDEX REGULATIONS & VICINITY MAP LEVIATHAN SOLAR INC Cl-COVER SHEET 1993 Pond Rd,Ronkonkoma,NY 11779 2020 NEC 1 +1 631-553-2732 R1-SOLAR LAYOUT AND ROOF INFO. 2020 BUILDING CODE OF NYS t r„ A:J �� into@leviathansolar.com ( 2020 RESIDENTIAL CODE OF NYS HI-65859 R2-PLOT SURVEY PAGE. 2020 EXISTING BUILDING CODE OF NYS 2020 FIRE R3-ROOF PLAN WITH MODULES. ; r TITLE: CODE OF NYS t COVER SHEET R4-RAFTER VIEW,MOUNTING DETAILS&BOM. 2020 PLUMBING CODE OF NYS ' } PARCEL ID: E1-ELECTRICAL 3-LINE DIAGRAM. 2020 MECHANICAL CODE OF NYS f �; 1000-023.00-01.00-011.003 jN CUSTOMER NAME: P1-PLACARD BREAKDOWN. GENERAL NOTES: Joyce Orrigo S1-EQUIPMENT SPEC SHEETS. 1.SOLAR PANELS WILL BE 10(REC460AA Pure-RX)WITH AN '+- ' CUSTOMER ADRRESS: OUTPUT OF 4.600 kWDC AND 10(IQ8X-80-M-US) 15925 Main Road S2-EQUIPMENT SPEC SHEETS. MICROINVERTERS. + .r East Marlon,NY 11939 2.INSTALLATION IN ACCORDANCE WITH MANUFACTURER S3-EQUIPMENT SPEC SHEETS. RECOMMENDATIONS. 3.ENGINEER TO INSPECT PROJECT AFTER INSTALLATION AND S4-EQUIPMENT SPEC SHEETS. CERTIFY COMPLIANCE. { F ; TOWn Ot SOUthold 4.PROJECT TO BE INSTALLED WITH CODE COMPLIANT 1` UTILITY: STAMP & COMMENTS: RACKING INSTRUCTIONS FOR SNAPNRACK SOLAR MOUNT �' PSEGLI SYSTEM. DATE: 12/20/2024 5.FOLLOW BALLASTING SCHEDULE ON ROOF PLAN. 6.THE SOLAR INSTALLATION CONTRACTOR,COMPLIES WITH DRAWN BY: ALL LICENSING&ALL RELATED REQUIREMENTS OF THE GOVERNING MUNICIPALITIES AND THE LOCAL ELECTRIC FELIX GONZALEZ UTILITY AHJ'S. Felix@leviathansolar.com 7.THIS PROJECT WILL COMPLY WITH THE CURRENT NEC «1 809-703-7147 (� V REQUIREMENTS INCLUDING ARTICLE 690 SOLAR \1r'! PHOTOVOLTAIC PV SYSTEMS. 8.THE ROOF WILL HAVE NO MORE THAN A SINGLE LAYER OF PLANS REVISIONS ROOF COVERING IN ADDITION TO THE SOLAR EQUIPMENT. �Qr1f 9.INSTALLATION WILL BE FLUSH-MOUNTED,PARALLEL TO AND 1 —/—/-- O `l NO MORE THAN 6.5"ABOVE ROOF 10.MAINTAIN A MINIMUM OF 18"CLEARANCE AT RIDGE AND AT 2 --/--/-- U ONE GABLE EAVE. 15925 Main Rd,East 11.THIS DESIGN COMPLIES WITH 140 MPH WIND Maion,NY 11939 REQUIREMENTS OF THE RESIDENTIAL CODE OF N.Y.S AND ASCE 7-16. Dam Pow �A, �EpED ARCM �tvi�C\�t�9 C�r1V 12.WHEREVER THE ROOF PLAN DOES NOT COMPLY WITH ��5 IFS 1 rSl �c W T014n O{ ACCESS AND VENTILATION REQUIREMENTS OF THE UNIFORM ¢ �� CODE,LEVIATHAN SOLAR PROPOSES THAT ALTERNATIVE VENTILATION METHODS WILL BE EMPLOYED.REVIEW AND APPROVAL SHALL BE AT THE DISCRETION OF THE x t MUNICIPALITY IN WHICH THIS DOCUMENT HAS BEEN FILED. -°S� A7T D216j�' y0Q 13.THE DESIGN PLANS COMPLY WITH THE 2020 NEW YORK F OF NE11 STATE UNIFORM FIRE PREVENTION AND RESIDENTIAL BUILDING CODE. LEGEND Lat: 41.136866 R 1 1"RIDGE )S•ROOE ACCE88 )S•OROUND SOLAR M-LE: U)R)TYMETER Lon:'-72.321574 ® SETBACK ® SETBACK ACCESS MC.-P.- � METER S:IPXOC;YS]09532 AC DISCONNECT MSP MAPA E-CE � ENVOY 58..". ACC P:W";BiMSt 2 36"ROOF ACCESS 36"GROUND ACCESS —PtE LEVIATHAN SOLAR INC 1993 Pond Rd,Ronkonkoma,NY 11779 +1 631-553-2732 VENT info@leviathansolar.com PIPE H I-65859 TITLE: m SOLAR LAYOUT 8L (N)ENVOY m ROOF INFO. (N)AC DISCONNECT UTILITY METER K CUSTOMER NAME: MAIN SERVICE PANEL 'v Joyce Orrigo SKYLIGHT CUSTOMER ADRRESS: CHIMNEY 15925 Main Road East Marion,NY 11939 AHJ: 36"GROUND ACCESS Town Of Southold UTILITY: PSEGLI 36"ROOF DATE: 12/20/2024 ACCESS DECK DRAWN BY: FELIX GONZALEZ Felix@llliathansol r.com t1 809-703-7147 PLANS REVISIONS N 2 DRIVEWAY aED ARC Joyce Orrigo F �y��5� 15925 Main Road v 10 PANELS 15925 MAIN ROAD r s 1 071633 yOP OF NE N LEGEND Lat: 41.136866 SOLAR MODULE: UTILRY METER 1/'RDGE arRooPRCeEss x'CRDuao LOn:-72.321574 SETaADN 4ETMCK 11CCER6 RECMOM PunA% METER/:1P%OC;YO///ST AC p18C0NNECT MSP MYv NEE E.- CC N:WXQC;9W-02 LEVIATHAN SOLAR INC 19,93 Pond Rd,Ronkonkoma,NY 11779 r1 631-553-2732 info@leviathansolar.com 161-11, HI-65859 TITLE: PLOT SURVEY PAGE a CUSTOMER NAME: Joyce Orrigo a1 CUSTOMER ADRRESS: 15925 Main Road East Marion,NY 11939 AHJ: Town Of Southold tS UTILITY: PSEGLI DATE: 12/20/2024 DRAWN BY: FELIX GONZALEZ Felix@leviathansolar.Com 26 9 +1 609-703-7147 PLANS REVISIONS N21 rcPED ARC 41 W E - r 07163" yOP S F OF NEN LEGEND Lat: 41.136866 R3 SOLAR MODULE: Lon:-72.32157 REGBOM PURE4U( STRUCTURAL RAIL Ba 1'PURE." ATTACHMENT i LEVIATHAN SOLAR INC 1993 Pond Rd,Ronkonkoma,NY 11779 info 631-553-2732(a�leviathansolar.com H 1-65859 2'-1011 171 TITLE: SOLAR PLAN WITH 2'-1 011 .I MODULES 13-5" p I CUSTOMER NAME: 2'-1 0" Joyce Orrigo CUSTOMER ADRRESS: 15925 Main Road 21-1" East Marion,NY 11939 1'-5" Town Of Southold UTILITY: 4' PSEGLI '-4" '-4" 1'-311 DATE: 12/20/2024 DRAWN BY: FELIX GONZALEZ 1 " 1 " 5n 22 -2 — Felix@lavialhansolar.cnm +1 809-703-7147 SOLAR LAYOUT: THIS ROOF WILL HAVE 10 REC460AA PURE-RX 460 WATT PANELS WITH AN PLANS REVISIONS OUTPUT OF 4.600 KW AND 10 IQ8X-80-M-US MICRO INVERTERS. 1 -/-/- 2 -/-/-- RAILS QTY. ATTACHMENT CITY. Roo(tilt Roof AZlmuln Attachment Fremirg Type Framing Size O/C spacing MAX,Attachment MAX.overhang Typo Spacing ROOF 1: 80 FT 1 6 PC$OF 172"RAIL ROOF 1:24 PC$ Root 1 24' 236' SNAPNRACK WOOD RAFTER 2"X10' 16- 64' 17' K, ED ARCy/ �I �c'3..$l l� 0 'rF OF NEB r Lat: 41.136866 R4 Lon:-72.321574 2N10"RAFTERS @ 16"O.C.(TYP.) RE0460AA Pure-RX SOLAR PANELS Ic I m LEVIATHAN SOLAR INC 1993 Pond Rd,Ronkonkoma,NY 11779 +1 631-553-2732 24" info@Ievia1hanwIarmm HI-65859 TITLE: RAFTER VIEW, MOUNTING DETAILS& BOM SPAN: 12'-7" CUSTOMER NAME: Joyce Orrigo ROOF CROSS SECTION RAFTER VIEW CUSTOMERADRRESS: 15925 Main Road N,T.S East Marion,NY 11939 AHJ: Town Of Southold UTILITY: PSEGLI DATE: 12/20/2024 gOM DRAWN BY: MID CLAMP SNAP N RACK UR-40 RAIL FELIX GONZALEZ 80 FT PV MODULE PV MODULE Feliz 1180ia703-71 ar.com 1F' +1 809-703-7147 ie** 0 PCS SNAP N RACK 6 PCS SNAP N RACK _ PLANS REVISIONS UR-40 RAIL UR-40 SPLICE ^ COMP051'nON SHINGLES SPEEDSEAL FOOT .W1 2Uz 26 PCS It 14 PCS 5/16-%4-LG.S.S.LAG BOLT WrrH HEROCENUR SNAP N RACK SNAP N RACK P.PRE-DRILL RED. (`PEO ARC T SPEEDSEAL FOOT MID CLAMP E)RAFTER Ow75*MINI * # 12 PCS 14 PCS r SNAP N RACK HARDWARE: SPEED AL FOOT OF DETAILS OF NE`N1oP END CAP GROUND LUG SOLAR MODULE SPECIFICATIONS AMBIENT TEMPERTURE SPECIFICATIONS tMRTER SPECIFICATIONS SERVICE INFO. Lat: 41.136866 E 1 TEMPERATURE MANUFACTURER/MODEL# QUANTITY NOMINAL OUTPUT NOMMULOUTPUT UTILITY PROVIDER:PSEGLI Lon:-72.32157 MODEL# VMP IMP VOC 1. COEFFICIENT MOF MODULES CONDUCTOR CONDUCTOR VOLTAGE CURRENT OF Voc RECORD AMBIENT TEMP TEMPERATURE TEMPERATURE I08x-804"S 10 240 VAC 1.SBA MAIN SERVICE VOLTAGE:240V REC460AA PURE-RX 118 9A5 M.7 10.07 -0.27%I'C 10 LOW TEMP (HIGH TEMP 2%) RATE(ON RATE(OFF MAIN SERVICE PANEL:200A . (46oW) ROOF) ROOF) MSP LOCATION:BASEMENT MODULE DIMENSION 68.10 L x 48 W x 1.26"D -15' 31' 90' 75' SYSTEM SIZE:lox 490W-4.e00 WVDC NOTE:i'PVC CONDUIT 1 0.3WW•7.8W MNAC RUN(7/8-ABOVE ROOF) LEVIATHAN SOLAR INC 1993 Pond Rd,Ronkonkoma,NY 11779 +1 631-553-2732 in(o@leviathansoiar.00m UTILITY METER#: H 1-65859 10 MICRO-INVERTERS IN BRANCH CIRCUIT#1 98009652 ACCOUNT#: O O_ O e5s1o1Dso2 (10)IQ8x-"-M-Us TITLE: MICRO-INVERTERS(240V) (LOCATED UNDER EACH PANEL) ELECTRICAL 3-LINE ti ti AC DISCONNECT DIAGRAM i I I I _______ `.�_____ __ `.-_----� L WA D CUSTOMER NAME: I. 15A Joyce Orrigo (N)(RODF),uNcnDNSOX CUSTOMER ADRRESS: (E)MAIN BREAKER 15925 Main Road 240V East Marion,NY 11939 z i AHJ: Town Of Southold aDA UTILITY: PSEGLI L---- - --- DATE: 12/20/2024 DRAWN BY: /,EXISTING FELIX GONZALEZ Felix@Ieviathansolar.00m +1 809-703-7147 PLANS REVISIONS DO SIP 2 -/-/-- CONDUCTOR SCHEDULE AND CALCULATIONS Wire Tag Wire Temp. Wire Temp. Conduit Deroted Inverter NEC Design Ground Ground Wire g Conduit Gauge Wire Type Rating Ampacity(A) Derote Fill Derate Ampacity(A) City NOC(A) Correction Current(A) Size Type PED AgCh c5 A OPEN AIR 12 AWG Q Cable 75'C 30 0.94 1.0 28.80 10 1.58 1.25 19.7SO00A 06 AWG BARE CU B I"PVC 10AWG THWN-2 75'C 40 0.94 0.80 30.72 10 1,58 1.25 19.75000A 10AWG THWN-2 * iI C 1"PVC 10AWG THWN 75'C 35 0.94 1 1.0 32.90 WA 1.58 1.25 WA 10AWG THWN d+x r 021633 OQ D I"PVC 6AWG THWN 71C 65 0.94 1.0 61.1 10 1.58 1.25 19.75000A 06 AWG THWN �TF OF NEB, -�WARI�N � Lat: 41.136866 P 1 SOLAR PV SYSTEM Lon:-72.321574 POWER SOURCE SWITCH FOR OUTPUT CONNECTION - EQUIPPED WITH DO NOT RELOCATE THIS SOLAR PV SYSTEMOVERCURRENT DEVICE RAPID SHUTDOWN LABEL LOCATION: LABEL LOCATION: SUB PANEL(AC DISCONNECT)&UTILITY METER SUB PANEL(AC DISCONNECT) LEVIATHAN SOLAR INC 1993 Pond Rd,Ronkonkoma,NY 11779 PV SYSTEM DISCONNECT SOLAR ELECTR C +1 631-553-2732 info@Ieviathansolar.com Pj'&WARNING PHOTOVOLTAIC SYSTEM PV PANELS H I-65859 ELECTRIC SHOCK HAZARD ! A DISCONNECT f l TERMINALS ON THE LINE LJ TITLE: AND LOAD SIDES RATED AC OUTPUT CURRENT 15.80 A PLACARD BREAKDOWN MAY BE ENERGIZED NOMINAL OPERATING AC VOLTAGE 240 V TURN RAPID SHUTDOWN SWITCH TO N THE OPEN POSITION � .�..•�• CUSTOMER NAME: I __ THE "OFF" POSITION TO SHUT DOWN Joyce Orrigo LABEL LOCATION: LABEL LOCATION: CUSTOMER ADRRESS: SCONNECT)&MAIN SERVICE PANEL MAHTSERVME PANEL&SUB PANEL(AC DISCONNECT) PV SYSTEM AND REDUCE r 15925 Main Road SHOCK HAZARD IN THE ARRAY >e East Marion,NY 11939 A WARN I N G _ - AHJ: LABEL LOCATION: Town Of Southold DUAL POWER SUPPLY SUB PANEL(AC DISCONNECT) UTILITY: SOLAR CONNECTION - - PSEGLI SOURCES: UTILITY GRID AND DATE:_ TE: 12/20/2024 PV SOLAR ELECTRIC SYSTEM J . E TAP DRAWN BY: LABEL LOCATION: LABEL LOCATION: FELIX GONZALEZ MAIN SERVICE PANEI &UTILITY METER MAIN SERVICE PANEL Felix@leviathansolar.com wi ewm +1 809-703-7147 MI•c ptcqnec• '•".....""" ® PLANS REVISIONS 0 WARNING _ �'-'-- 2 --,_,-- TURN OFF PHOTOVOLTAIC �. AC DISCONNECT PRIOR TO = IN7WNINOM OWER SOURCE PEo ARC WORKING INSIDE PANEL sr F LABEL LOCATION: LABEL LOCATION: b •o� •• (�• * • JUNCTION BOXES 8 MAIN SERVICE PANEL CONDUIT&JUNCTION BOXES 159a5MalnR ro—ELS s� 021633 yOQ 15925 MAIN ROAD TF OF NEf1 Lat 41.136866 C Lon:-72.321574 J ALPHA" ♦ 1! .tY SOLARS MOST TRUSTED R E REE ALPHA° GENERAL .%TE LOAT♦ _ 881 W f<ut 6;laoal REC MterKsrr[Lion teNs C.a Tvp wfga0 -Hog' GIs 32mmsdargl ,-hand.fmtiwwrtxetreatmenl .._ PURE-RX SERIES - .a.m..ew-.(Bm ) e.dr,l..t �IrrK„tern polyrm,9aekl F.. Arad etl.kb,m6 k) 4pet,ryp,„dpJ.A 3 IP6ar,teama.PVABTwKST4(4z790 LEVIATHAN SOLAR INC c4..m: EC6DYFK4PVX6T4/KSTal4m �rt ac..rmrtew�ml6c szR52 v6Rmtywhm<anedM 1993 Pond Rd,Ronkonkoma,NY 11779 DATASHEET C�1e sal.rc,6le 17m.17m +1631-5532732 xcprdarcewithEN50Gla Ok...i— 1726.1205.30mm(2.08.el 1 in(0(�I@vlalhan6dar.LOr11 1v.y. 227ig H I-65859 j3FCTRCAL• Pill icircom-REC-Mp-m A••YJ1T08 g TITLE: 114..rOAPA-V-(wj 450 455 460 465 470 IEC 61215202L EC617302016.LlL61730 F EQUIPMENT SPEC • w. Ch..S d%-(wt 0/.sw 0/.5w 0/.Sw 0/.5w 0/.Sw I50119 E(62 -z IgMtaahty(w135o1-1c14ssE) • N.dr.11bwrvdet�-v-m 543 5°6 54.9 S52 554 ECWA, Sa1MtMlstj5pA6) . F SHEETS EC60S" N.gstaret35^•w) 2 �' e3e fl°3 &09 LJL61730 FwTsy42 & CUSTOMER NAME: Op.r—vbl,ve(v) 651 652 6S3 655 656 ISO 14001.609001;EC45001,EC62941 . Sh-Cv.*Carwrt-I,W Rol 684 686 891 995 s Joyce Orrigo P-0.r.1er(w/.m 216 219 221 224 226 CUSTOMER ADRRESS: tr.Vr.,p pl—imd—'m 216 219 221 R3 226 &` '6•IC E M N 15925 Main Road East Marion,NY 11939 P—.WW-1V j•a 343 346 350 3S4 356 Nee4r.lP~vbltw-v_(v) SL2 514 51.7 S20 522 AHJ: Z No.iW P—C.r.tt-t—m 670 673 677 661 666 •,ULE CURRENT 0,-Ck tvtw-ve(17) 6L3 615 616 61.7 619 st.d.d 6ECR.Trms Town Of Southold shorlcka,ttc4.,.rn-I,w 70 7A 7.17 72 723 e. Y. UTILITY: COMPATIBLEERR ,. ®w — _..r W R.fsb W PSEGLI ..e.4anr_ e.�s.. wr,"Mv- aa aw.:� S.,r-sfs 20 zskw zs-s0ok5 DATE: 12/20/2024 R°°'.`w'"'"T 20 a a IM)011MRxnN ' 761MIRAIR RATROW (7-1 op..tw.1 T-p-.... 'lo•c es•c N.eirML,md,Op., q 4,•C:zY P w.r." 25 a a DRAWN BY: sr..w vplt.g. loo0v T.rrp.— La W-." 0 a 10 FELIX GONZALEZ 1,.ox...T-L-I 6-1 .7000P,(713kW7') T.rrrp..e..meErd.redv,,, -024%/•e h"j MW—T rL"ej,-) 4o00P,1407t9/"LAv acres Cv rew n.rrp.atr..�.16r1-dl 024%/•c P—blv"l 98% 9R% 911% ' Felix@leviathansolar.mn M.SMFp " 25A 004%/•CA-Wo A025% 025% 025% t +1809-703714725A Pdsr r,vr25 92% 92% 92% m '•` .. ., �-r..,..dr sr...,.,1 06JVW*#01tlA11710N e.'m em:<.v.a sd.nd.,,o..k.er w...rtr nr✓v we 4 Fw1.p.r P«Nt 33 g PLANS REVISIONS P..kl-40arr/N0 594(18Pa11-) Il11VUGLgr641VI011R u• r . P.rdsewllfi.4 660(20Pa11-) TM,.1 modrket STC RED ARC 3..ST 47 -- 99fi R((< rzn mrm.naw prowrx2w�rm:gyrmyvey rtavnMror:�+nwn+grM.... ..4. m-..imr4art axr,rMGY �L� L� ¢ — `cM poww As Splrr Mpar i�,nrM RfC nromn nec reA p.I rr rwm'no.aide owrnLa.fm.aw nrM:da AiwcSwm Aw l4 1r 1C .n .un r.n.n rwp..rw.a,rx. v w^ m+^r+dw+r+.rS.Ram..Rtta.ovr•a rvm,w..nAw,... S�vepoe637;12 �" ! r„iapr.re,n Avn rr,nr w.6wNoprun ,� 1 0F NEB Lat: 41.136866 �+ Lon:-72.32157 J v ENPHASE. ® I08X Microinverter ConwaNy uas0 nlod,k p.Yk,a' w 320540 saod4ecompNroanr ro creel oomp,tiWity,w modWa mrst Ea wtMn W.trnput DC wha9e.nd t4ean,oAAaI.Yueaww ModM-nios A;"rJn tie ctrrled.t mtp¢.'/tease. _ ,.Ilua^NaMtvwtw✓CebWV MPVT-hues•nye Oper,ta,rape v 25-795 zxKw,m.�w.l,w,mmn.Plt.g. • 3 m!k LEVIATHAN SOLAR INC w..input x.on.ge r ,es 1993 Pond Rd,Ronkonkoma,NY 11779 w..d«n.anona aP..e;tie oc n,n.rrt . 10 -1631-553-2732 ­wmy~-acen azrsa • 1e info@leviathansolar.com w neaA.l. u HI-65859 orwwn.9.a..a oc v«, a OC pPrt b,ctiwa tin.,, .. o w an,r�nnr„r.,bn taquu^dedurry:rw addnmal DC sde lza.Pnennvn►.a Ac+depret.ud9v,reank.a mu lOAp�En 1hvzMt TITLE: EQUIPMENT SPEC Pesknutpm Power r+ 3tw Sea SHEETS w..co-rtYupnwrtput va„w w 3w 360 IQ8XMicroinverter Nnmw.emn.�tL-L) r 2-Nstph.sea-0., -6 6ph...(L0.12(r CUSTOMER NAME: N;mum.M wumum prd rdt,ge' r 211 183-229 Joyce Orrigo Our newest lQ8 Sw N,sMtaomvartersere the Industry',first mlcrogrid-f«mN,;aonware- Eery to kutea �E�nedm< mercer,-hsoI-,ha,egower�on, ,ion�aoabklylo^^m 11.po e b w"°"'"" '°m"`°•^ � CUSTOMER ADRRESS: AC power el6claOtifF Ca%Microinverte,Is the latest addition to this iamif.designed to support Lphtwelgnt end compac1.1h plug- aD 15925 Main Road PIE mod,les with higher input DC voltaga end cell count,.such as 96 tail,.80 halt-cut—11,. and-play mmtecton E.—F w and 58hall-cut call,TheI,-ofth w—unductor-based—cinwrir—proprietary .Powerhnecpmmra,cal—WLC) per w,a. 4,ea East Marion,NY 11939 npplcatbn-apecdlc Integr,ted clrctM(ASIC).which en ver enables the m—nter to operate in between con„p«,ents AC aMt ckcult bolt cv.wd or.n 1lxsct�.rw 2.10 grid-fled or off-W id modem.The chip is built In advanced 55 rim lechnobgy ME,high-speee w..own Pu 20 a R-U ben,ri,c.M' to B dg"al bgb,rrd h,s wperfeat response time,to cher,ir,loads and grid events.alleviatir, F,ater insteaetdn will simple two-puke emstraima on battery,siring for home energy systems. Cabling r«.Ilwmmlcdenortlon x .s AHJ: a>aw„.ge—. pn,t Town Of Southold High roduce xdlWt,—andr fan hefty AC Port beckl.etl curlw,t .A 16 UTILITY: produces power even when the grid is Power aPmr wmy, t o PSEGLI 'own• More than one-11-cumulative hours crld-fled power i.ct«(auks,. ) o.951eads,,.o.951.g9vg DATE: 12/20/2024 P,rtcfth9Enhad Ever9Y ri S tam. 08 Series U-ninvet—ni,define of t'sting Peal sfM1.y x B7a B14 oas.:arxmkwe^enintegramwdn r'habihtYatard.reawdnm«ethan Class ndopde-i„apetedendb,— cEcweymwetn.,.,,rr eu sae DRAWN BY: it.IQ B,dwy.IO Gateway.and the ftilion cumulative hours of power-on Op—Fact la the latest high-powered Erpi—App mom«mg and analysis tearing,ena bung an industry-leading Pv modalea 22 29 FELIX GONZALEZ loftwere limited warranty of-to 25 years. Feliz@leviathansolar.com MI«ogres-ro.ming Anmwn,I——nanq. -4onCbaSC(-4vEmt4m .1 809-703-7147 © Complies with the latest advanced grid RN.tlwnumd,y range 4%toltilote drJg) >ePPO `«w.n ""�DC '°' PLANS REVISIONS latest Rem grid rpnahc upd requkemen[s ates for,hn Umenwona(N•W.D):Weight 212 nsnMY).175 osn(6.9').301mm(1.2'):11 kg(2.43 ba) grid Connect PV modk.quickly and easily 1095edes M;cranvertera are UL listed Configurable to support a-derange CnoYn, NMwel mnvalnbn-^°fans, to the IOa Se,is*Wrobrarten that Aare u PVrapW shutdown equipment and of9mprofiles Apprond br wet bcmmr.Poaunm deer'' yr'PD3 integrated MC4 connectors. conform wdh va—,gulanons when Meats CA Rule 21(UL 1741-SA)am IEEE Encbwa. Con amwl.-.n.A.ted.corroron-nat.nt Polym.,k 2 Installed a000rding to Me manufacturer's 1547:2018(UL 1741-SB) Imtructbns. km��o�category:UV aquae'raw, IE W Type6',outdoor •owyrriwre.�mlo svuunemndw 2.m«uur,.t. o• ev'•a 1OP^w CAlkN21(MFFi-W.UL 62MI.EEE 1547:2016(UL1,41-50).FCC f+er„5 C1na8.10ES-0003Cuas B.CAN/CSA-C222NOb71- weNa..,awlrw'a.,eaaeet— Gniritiom TM1Ypahct 41A Lhtsd ar PV,Npdslutdownequipment—on—NEC 2014.NEC 2017..ne NEC 2020 settwn 69012--1-20. PED Aqua fm sww,toea.w.ee.ewwn.w.ww. 11J.61-2B npb sBatmwnwwar•�wrw fw AC,M DC cmduct«>wMn nsleibd xrae:q+o,till manuterturer'a ins,ructiam. y'�F' 7..$ y/ mxe.�moc/ac r,ro `ram _`F,S l A23—Frwrer.4 rpMarw.rvtl EryNwevv WCC iegoa tq.n4catanaarr mob Nadu 13)brwW.dtq.rrpo.b�w��64k.vo'4.awre�4..4 N'fwWry. e , �n arLMn e.r•.ry adato trJwaw.snnsnoe.Frm.rues almno-wrtwvgr trwcnuyww Q 1e A Mm�vupwre canr,..a..ran-gage-gwfevrea ue,rtleoubd Enprvr.Frwrpr.Yc.n Ma US uq 4tMr ca.rrNa - Dw,e<pc,o Wp gaai/U-D9N OO,Ie W-Fe-IA]OTa o,n iOb.MCv JSM M]1N1 I�FA 1a.v'J]Oatl Il r 4PA 021633 yOP OF IN N Lat: 41.136866 e Lon -72.32157 V UR-40 Snap rack- N.• UR-60 Solar Mounting Solutions • Ultra Rail ••• LEVIATHAN SOLAR INC The Entire System is a Snap to Install 1993 Pond Rd,Ronkonkoma,NV 11779 •New Ultra Rail Mounts include snap-in brackets ♦1 631-553-2732 for attaching rail info@leviathanwlar.com •Compatible with all the SnapNrack Mid Clamps HI-65859 and End Clamps customers love •Universal End Clamps and snap-in End Caps provide a clean look to the array edge TITLE: EQUIPMENT SPEC of SHEETS Unparalleled Wire Management CUSTOMER NAME: •Open rail channel provides room for running Joyce Orrigo wires resulting in a long-lasting quality install CUSTOMER ADRRESS: •Industry best wire management offering 15925 Main Road -- includes Junction Boxes,Universal Wire East Marion,NY 11939 Clamps,MLPE Attachment Kits.and Conduit Clamps AHJ: •System is fully bonded and listed to UL 2703 Town Of Southold The Ultimate Value in Rooftop Solar Standard UTILITY: PSEGLI DATE: 12/20/2024 Industryleading Mounts .available for Management • • •• •- Heavy Duty UR-60 Rail DRAWN BY: •UR-60 rail profile provides increased span FELIX GONZALEZ capabilities for high wind speeds and snow loads Felix@levialhansolar.wm Single ••l Installation All . •Nrack Module •Taller,stronger rail profile includes profile- -1 809-703.7147 ClampsAccessories specific rail splice and end cap • •• • - •All existing mounts,module clamps,and PLANS REVISIONS are accessories are retained for the same great both rail profiles install experience Of 1 -/—/-- 2 /—/-- RESOURCES snapnrack.com/resources Quality. Innovative. Superior. "IpED ARCM 5 ).. SnapNrack Solar Mounting Solutions are engineered to optimize F material DESIGN snapnrack.com/configurator labor resources and impro -overall installation quality and WHERE TO BUY snapnrack.com/where-to-buy * It r 02163� JOP TF OF NE N Of SOI/TyO6 10 � � r)� * TOWN OF SOUTHO D BUILDING DEPT. C' ........... � �o 631-765-1602 I NSPECTION [ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND - _ [ ] INSULATION/CAULKING [ ] FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ' ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) " j ELECTRICAL (FINAL) . [ ]- CODE VIOLATION [ ] 'PRE C/O a [ ] RENTAL I REMARKS: c L /4-Q t , 1 C, �( �n l� oil L C — - - i DATE INSPECTOR