Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
50245-Z
aoe soulyo`o Town of Southold P.O. Box 1179 Ao� 53095 Main Rd Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 46297 Date: 07/07/2025 THIS CERTIFIES that the building GENERATOR Location of Property: 706 Wiggins Ln Greenport, NY 11944 Sec/Block/Lot: 3 5.-4-18 Conforms substantially to the Application for Building Permit heretofore,filed in this office dated: 12/15/2023 Pursuant to which Building Permit No. 50245 and dated: 01/23/2024 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: Accessory generator as applied for. The certificate is issued to: Nastasi J Rev Trt , Ieraci A Rev Trt Of the aforesaid building, SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: 50245 4/26/2024 PLUMBERS CERTIFICATION: c tho a Sig ature �o�SUEfel,��oG TOWN OF SOUTHOLD , BUILDING DEPARTMENT TOWN CLERK'S OFFICE o . SOUTHOLD, NY y p! BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 50245 Date: 1/23/2024 Permission is hereby granted to: Nastasi, John 146 W 74th St Apt 5 New York, NY 10023 To: install generator as applied for. Must maintain minimum 10' setbacks from lot lines and provide protection from vehicle impact. At premises located at: 706 Wiggins Ln, Greenport SCTM #473889 Sec/Block/Lot# 35.4-18 Pursuant to application dated 12/15/2023 and approved by the Building Inspector. To expire on 7/24/2025. Fees: ACCESSORY $125.00 ELECTRIC $100.00 CERTIFICATE OF OCCUPANCY $100.00 Total: $325.00 Building Inspector OF SO!/r�,o Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 �o sean.devlin(c-o-town.southold.ny.us Southold,NY 11971-0959 COUNTY,�� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: John Nastasi Address: 706 Wiggins Ln city:Greenport st: NY zip: 11944 Building Permit#: 50245 Section: 35 Block: 4 Lot: 18 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: License No: SITE DETAILS Office Use Only Residential X Indoor X Basement Service Commerical Outdoor X 1st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey Attic Generator X INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures 11 Sump Pump Other Equipment: 24kW Generac Generator w/200A Whole House Transfer Switch Notes: Generator Inspector Signature: _ Date: April 26, 2024 S.Devlin-Cert Electrical Compliance Form OF SOUTyolo -SO -2-Ll v (atV/ l/L� * TOWN OF ioUTHOLD BUILDING DEPT. couMv��',o 631-765-1802 INSPECTION [ ] FOUNDATION 1 ST/ REBAR [ '] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY- [ ] FIRE-SAFETY INSPECTION [ ]' FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ]. PRE C/O [ ] RENTAL REMARKS: w DATE' INSPECTOR ho�atf Soil # TOWN OF SOUTHOLD BUILDING DEPT. `ycourm,a�' 631-765-1802 A0 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ NSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: V yj DATE INSPECTOR OF SOUTyo� TOWN 'OF SOUTHOLD BUILDING DEPT. CO 631-765-1802 1 NSPECTION [ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. [ . ] FOUNDATION 2ND [ ] .I LATIOWCAULKING [ ] FRAMING /STRAPPING [ FINAL Q,/ [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ J FIRE RESISTANT:PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: C DATE INSPECTOR FIELD INSPECTION REPORT DATE COMMENTS Q FOUNDATION(IST) j. FOUNDATION(2ND) z s H ROUGH FRAMING& y PLUMBING Ic . s 1 S Gl . INSULATION PER N.Y. y STATE ENERGY CODE of on FINAL ADDITIONAL COMMENTS - - Z �rn L � O 0 z x b G =O�gufFOl* TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,N'� 11971-0959 Telephone (631) 765-1802 Fax (631) 765-9502 https://www.southoldtowmy.gov Date Received APPLICATION FOR, BUILDING PERMIT or Office Use Only PERMIT NO. Building Inspector. i a EC 1 r i o23 Applications and forms must be filled out in their entirety.Incomplete' applicationsP.` will not be accepted. PP `.. Where the Applicant licantis not 'o wner,wner and' Owner's Authorization form(Page 2)shall be completed. `- Date: OWNER(S)OF PROPERTY:. Name: SCTM#1000- Project Address: -2Q Phone#: Email: Mailing Address: CONTACT PERSON: ` Name: } 2 Mailing Address: Phone#: �31� Email: DESIGN.PROFESSIONAL INFORMATION: ' ; Name: Mailing Address: Phone#: Email: -CO ONTRACT611"INFORMATIONi Name:. .. Mailing Address: ��c` C✓ Phone#: Email: o�RAG 7a-� o_ .=f l,�_ DESCRIPTION OF PROPOSED.CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: [Other eo!% Age- $ _ Will the lot be re-graded? ❑Yes ❑No Will excess fill be removed from premises? ❑Yes ❑No 1 PROPERTY INFORMATION Existing use of property: Intended use of property: Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? []Yes []No IF YES, PROVIDE A COPY. El'Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building.Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section,210.45 of the New York State Penal Law. Application Submitted B (print name h i� `I r, ❑Authorized Agent ❑Owner Signature of Applicant: i// Date: CONNIE D.BUNCH Notary Public,State of New York STATE OF NEW YORK) No. 01BU6185050 SS: Qualified in Suffolk County COUNTY OF ) Commission Expires April 14,2ay" being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the (Contractor,Agent, Corporate Officer; etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed'in the manner set forth in the application file therewith. Sworn before me this 164-41 day of 20 CMS �nG� Notary Public PROPERTY OWNER AUTHORIZATION (Where the applicant is not the owner) I, residing at do hereby authorize to apply on my behalf to the Town of Southold Building Department for approval as described herein. Owner's Signature Date Print Owner's Name 2 ' PPF.l3TY INFdRMAi} RO ON Existing use of property: Intended use of property: Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes []No IF YES,PROVIDE A COPY. ® heckBoxlfterRead�ng fieovmerjcvntractor/designpmfessionalLsres�onslbtefara0dratnageartdstonnvraeriswesasprov144jby y Yha"' 6oftlieTewnGode APALtCA7tOi1S lERE61CM�tiEtotheB�dldtngDe a%tmecrtfar a&tss ceofaBuitdtngPerm pursuant to the Building Zone ; ordina�te�aFhekTownof5aathtltd,5uffotk,�'�,HeyrYarkandotb�e�,appl"ieabCetaws,OrdtnancesarRegnFatta`,fortCteKoo�sinacbonof6uild�iigs,', ;' r' ..ten .r rzw a. "�,•. a,,,. �`�w� :..,#! ''? :..�..z • .Y # � s:. a, 2 ,l ,y.,- dTons,alera8onsooFremovaCordemolonati eeteutdesciibed Ifie,appttptrtagreestocamptStwifhattapplicabtearou;,ord nces,buitdingcode, egyl q, iasp ' z preandtabuAdufg(s};for,nets;saryinspectlons.Fatse`sLateinerttcmadeherelnare >4 hadd nusLigcodeartd atwnsandtoadrrfitautfitlr¢ed ecton:on PW"habteas UassAmtsdemeanorparsaanftasectxon21DA5oftheNewYorkState>enallaiv ` _. ._`�; Application Submitted By(print name):�6 ht j,�zZi',, �1 r ❑Authorized Agent I❑Owner Signature of Applicant: Date: 7 5;� ONNIE D.BUNCH Notary Public,State of New York STATE OF NEW YORK) IVa,01BU6185050 SS: Qualified in Suffolk County COUNTY OF ) Commission Expires April 14,20nLq being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this /� L day of 20 �sGn Notary Public PROPERTY OWNER AUTHORIZATION .(Where the applicant is not the owner) I, jcgu k4sAS1 residing at � �' do hereby authorize -to apply on my behalf to he Town of Southold Building Department for approval as described herein. wner's Signature Date Print Owner's Name 2 r� ffC ' BUILDING DEPARTMENT- Electrical Inspector auy - TOWN OF SOUTHOLD ' - Town Hall Annex- 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 rogerr(c�southoldtownny.gov seand c(D outholdtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: /;t-ls_ ,T Company Name: r� �; � 7�'. e- Electrician's Name: ,���� ����,f►z�, v;_ License No.: Elec. email: �Jr ,� o �� 17e Elec. Phone No: El request an email copy 9f Certificate of Compliance Elec. Address.: d dr�„�,,..✓ G•� _ JOB SITE INFORMATION (All Information Required) Name: p Address: 70 Cross Street: Phone No.: Bldg.Permit#: email: Tax Map District: 1000 Section: 3j Block: Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): l/UG G✓ �. 4/ i'/�o / Square Footage: . Circle All That Apply: Is job ready for inspection?: ❑ YES O ❑Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect[]Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 2 H Frame Pole Work done on Service? M Y N Additional Information: PAYMENT DUE WITH,APPLICATION REVISION no description date i- Face of Eaisang Enencr Wall - _ /l-\ —. — NevUMergrowtl Electr.to House — — — — — — — _Panel \ r 1, Required 5 Clearance 1 \ From Windows& � i / - _ 1 �. _ -, —_ —I L oor\Ds jj I/ 5-q - ' Underground Gas Service to Generator [Side Yard] =' - 1 1 -- - -- ----- 1 -Con-le Generator Pad by Geenpada Guardian Series Full 03 House Generator by Southold Building Dept 121082023 Gene- 02 Southold Building Dept 09/022023 Side Ya4d] Required Min.3 01 Southold Board o1 Trustees 09)072022 i I Wo,king Clearance no towhom issued date Around Generator - i ISSUE -27T-' 0 1 n Properly Line \/ Gravel Area 0 A— OWNERS) 706 W astasLaAnnmarie leraci 99ins Generat0-�Ocatton GrcenPon,NV 11944 'r 6 Scale.1/4,_1,-p„ -- 5-2' 6 78 - ' 42'Z 1 7' - �-�--- --- - - - -- --- i- -'---- 'T Stair God t0 ;= :- Rear Yard--- - 1 1 _ C 1 12' zR rp \ [Rear Yard[ /� 13' -'3}16 66 1 t _ � `1� '•� -- oN oN -4 1 Greenport 11 , �3Bisgtsgz(2)Risen,Upto/� Residence •1 1.2' O Wood Deck- -____ _ __ t� 1 ,� \ \ 01 ✓-i—----- —i �I I � 1 �� •`� ''\ 706 Wiggins Lane Greenport,NY 11944 i 1 y--- 1 0 Porcelain Paver Terrace 1 _ o' _ - -i ` t Suffolk County Tax Map No.: 1•11 - _ A 1 ^�- r _—-,�_-- ___ 1 \ _ 1000-035.00-04.00-018.000 auto wear vauli nastasi _ u'-o•. 1 1 1 ` architects i'-2• 1'-2',f 15.73' w f 1 A_V/ a 7-0' E 1 r-----Expanded Gravel 1 <N ` Area - = New ln-Ground Pooh i 1 ExistinGrave riueway o 1 � 1 I '-p� �\ — r�F;AVE `ICFIV VvAi �T a�,nea�s•,�ho�o�n.nleo�P 11. Y :zoassnn r zmbszzsn ur<nrecs.con _ 1 NJ license.All 1550 —_ T L 15.I3' T }�' I � (Sarvey 1 NY license:021570 Garden at � 1 � — 1 - Jo� Grade C'H 1 fl -j Site Plan \ - 15'Required Setback 1y \ ` _0 _ September.fi = _ [Side Yard] 1_� �� 1 �I ! _ 1 -i 11:71 �,�✓�:_:�. _ _-O 3O-` -_ Oi/�.L� - F ) __ date. 07,2022 ..Is as shown drawn by. AN —"-- checked aa S sked EY' JN an \` ✓�- • phase Plan P, Site Plan _ 2 Scale:1/8"=V-0 Al 01 .00_� OH GENERAC® ;14MEI AS ps GUARDIAN® SERIES _ DATB.P.# i sidential Standby Generators F� BY: Air-Cooled Gas Engine NOTIFY BUILDING DEPART AT 631-765-1802 8AM TO 4PM FOR THE FOLLOWING INSPECTIONS: Standby Power Rating INCLUDES: 1. FOUNDATION • True Power'" Electrical Technology FOR POURED DiV ;;- • Two-line multilingual digital LCD Evolution`"controll2. ROUGH-FRAMING& rt. (English/Spanish/French/Portuguese) I INSULATION • 200 amp service rated transfer switch available 4. FINAL-CONSTRUCTION MUST BE COMPLETE FOR C.O. a� • Electronic governor ALL CONSTRUCTION SHALL MEET T • Standard Wi-Fig connectivity REQUIREMENTS OFTHE COD W • System status&maintenance interval LED indicatorsYORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTON ERRORS • Sound attenuated enclosure ELECTRICAL !— • Flexible fuel line connector INSPECTION REQUIRED — • Natural gas or LP gas operation i GENERAC • 5 Year limited warranty L ---------- • Listed and labeled for installation as close as 18 in(457 mm)to a structure.* - *Must be located away from doors,windows,and fresh air intakes and in Product shown wit optional fascia kit accordance with local codes. COMPLY WITH ALL CODES OF LT�g or 401111IS �v� 1 NEW YORK STATE &TOWN CODES `IV r � AS REQUIRED AND CONDITI S OF LISTED SOUTHOLD TOWN Note:CETL or CUL certification only pappliees to unbundled units and units packaged with limited circuit switches.Units ackkaa ed with the Smart Switch are ETL or UL SOMOLD T PLANNING BOARD certified in the USA only. O FEATURES SORO oWNTRUSTEES N18, are at the heart of Gen- This erac's success +hP, a Hnsible. Generac's G- state-of-the-art power maximizing regulation system is standard on all Generac mod- Force engine lineup offers added peace of d reliability for when it's needed els.It provides optimized FAST RESPONSE to changing load conditions and MAXI- the most.The - built and designed to handle the MUM MOTOR STARTING CAPABILITY by electronically torque-matching the surge rigors of extended run times in high temperatures and extreme operating conditions. loads to the engine.Digital voltage regulation at±1% Superior harmonics and sine wave from Generac's extensive dealer network form produce less than 5%Total Harmonic Distortion for utility quality power.This provides parts and service know-how for the entire unit,from the engine to the small- allows confident operation of sensitive electronic equipment and micro-chip based est electronic component. appliances,such as variable speed HVAC systems. Long life and reliability are synonymous with PROTOTYPE TESTED NEMA MG1,22 EVALUATION GENERAC POWER SYSTEMS.One reason for this confidence is that the GENERAC SYSTEM TORSIONAL TESTED MOTOR STARTING ABILITY product line is offered with its own transfer systems and controls for total system compatibility. FREE with select Guardian Series Home standby generators, Mobile Link Wi-Fi allows users to monitor generator status from any- OCCUPANCY OR where in the world using a smartphone,tablet,or PC.Easily access information such as the current operating status and maintenance alerts. Users can connect an USE I� UNLAWFUL account to an authorized service dealer for fast,friendly,and proactive service.With Mobile Link,users are taken care of before the next power outage. WITHOUT C E RTI F I CAT w GENERAC n4''�* � � OF OCCUPANCY �IPROMISE '�9 `��` EM �,. s f .z.6 R 4 a y3�x 20/22/24 kW Features and Benefits • Generac G-Force design Maximizes engine"breathing"for increased fuel efficiency.Plateau honed cylinder walls and plasma moly NER rings help the engine run cooler,reducln OII consumption and resulting in longer engine life. • "Spiny lok"cast iron cylinder wallsRigid construction and added durabilityaprgyide long engine life • ElectroniC.ignition/spark advance These features combine to assure;smooth,quick starting every'time • Full pressure lubrication system Pressurized lubrication to�allrvital bearing,means better performance leses maintenance and ionger engine -,pro t life.Now featuring up to a 2 year/200 hour oil change interval: • Low oil pressure shutdown system Shutdown protection prevents catastrophic gngine damage due fo low oil. _.'t .i • High temperature shutdown Prevents damage due to overheating.:, �ii .x. • Revolving field Allows for a smaller,light weight unitithat ogeTates 25%more efficiently than a revolving armature generator. • Skewed stator Produces a smooth output waveform-for compatibility with electronic equipment. .. 1 • Displaced phase.excitation Maximizes motor-starting capability - 6? • Automatic voltage regulation Regulating output voltage to±1°h;:p�edenfs,"damaging voltage spikes. • EPA Certified for non-emergency applications i Allowsunit to,be usetl.for de`maodiresponseYapplications(excluding 20 kW units). • UL 2200 listed- Foryour safety..,%i • Fully automatic Transfers vital electrical loads to the energized source of power. • NEMA.3R Can be installed inside or outside for maximum flexibility. • Integrated load management technology Capability to manage additional loads for efficient power management. • Remote mounting Mounts near an existing distribution panel for simple,low-cost installation. 40 -AUTO/MANUAL/OFF illuminated buttons Selects,the operating moddai`d probides,easy;at-a-glance°status indication fin,any condition. • Two-line multilingual LCD Provides homeowners easWvisible'logs of history,maintenance;and:�events up to 50 occurrences. • Sealed,raised buttons Smooth,weather-Fesistantluser ihte`rface for'programm ing•and,operationsf.' • Utility voltage sensing Constantly monitors utility voltage;setpoinis,65.%-dropout 8O° gieLup-QLstandard voltage. • Generator voltage sensing Constantly monit�rs generator voltage.toiverify thetciearrest power delivered to the home. UPAJUQiOa,,JiYiTS/7 d.•VI it."WV, • Utility interrupt delay Prevents nuisance start-ups.of:the,engine,.adjustable,2:1500 seconds from the factory default setting of 5 seconds by a qualified dealer��4'�nI - • Engine warm-up Verifies engine is ready to assume the load,setpoint-approximately.5-seconds-- • Engine cool-down Allows engine to cool prior to shutdownms itpolnt)ap�fe}^frq! el 1 minutes • Programmable exercise Operates engine to prevent oil seal drying and damage�bZtween power outages by running the generator for 5 minutes every other week.Also offers a selectable"setling or"we�`Cedy�`r'monthly operation providing flexibility and potentially lower fuel costs to the owner. • Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM-style batteries. • Main line circuit breaker Protects generator from overload. • Electronic governor Maintains constant 60 Hz frequency. • SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature, withstanding winds up to 150 mph(241 km/h).Hinged key locking roof panel for security.Lift-out front for easy access to all routine maintenance items.Electrostatically applied textured epoxy paint for added durability. • Enclosed critical grade muffler Quiet,critical grade muffler is mounted inside the unit to prevent injuries. • Small,compact,attractive Makes for an easy,eye appealing installation,as close as 18 in(457 mm)away from a structure. GENERAC 20/22/24 kW Specifications Model G007038-1 G007042-10 _GO07038-3 G007042-11 G007209-10 G007039-1 G007043-10 G007039-3 G007043-11 G007210-10 '(20 kW) (22 kW) (20 kW) (22 kW) (24 kW) Rated maximum continuous power capacity(LP) 20,000 Wafts" 22,000 Watts` 20,000 Watts' 22,000 Watts' 24,000 Watts' Rated maximum continuous power capacity(NG) 18,000 Watts' 19,500 Watts' 18,000 Wafts' 19,500 Watts" 21,000 Watts` Rated voltage 240 Rated maximum continuous load current—240 volts(LP/NG) 83.3/75.0 91.7/81.3 83.3/75.0 91.7/81.3 100/87.5 Total Harmonic Distortion Less than 5% Main line circuit breaker 90 amp 100 amp 90 amp 100 amp 100 amp Phase J 1 Number of rotor poles 2 Rated AC frequency 60 Hz Power factor 1.0 / Battery requirement(not included) 12 Volts,Group 26R 540 CCA minimum or Group 35AGM 650 CCA minimum Unit weight(Ib/kg) 448/203 466/211 436/198 445/202 455/206 Dimensions(L x W x H)in/cm 48 x 25 x 29/121.9 x 63.5 x 73.7 Sound output in dB(A)at 23 It(7 m)with generator operating at normal load" 67 67 67 67 67 Sound output in dB(A)at 23 ft(7 m)with generator in Quiet-Test-low-speed exercise mode" 55 57 55 j 57 57 Exercise duration 5 min Engine type GENERAC G-Force 1000 Series Number of cylinders 2 Displacement 999 cc Cylinder block Aluminum w/cast iron sleeve Valve arrangement Overhead valve Ignition system Solid-state w/magneto v Governor system Electronic Compression ratio 9.5:1 Starter 12 VDC Oil capacity including filter Approx.1.9 qt/1.8 L Operating rpm 3,600 Fuel consumption Natural gas ft3/hr(m3/hr) 112 Load 204(5.78) 228(6.46) 164(4.64) 203(5.75) Full Load 301(8.52) 327(9.26) 287(8.13) 306(8.66) Liquid propane ft3/hr(gal/hr)[Llhr] 1/2 Load 87(2.37)[8.991 92(2.53)[9.57] 86(2.36)[8.95] 92(2.53)[9.57] Full Load 130(3.56)[13.48] 142(3.90)[14.77] 136(3.74)(14.151 142(3.90)[14.771 Note:Fuel pipe must be sized for full load.Required fuel pressure to generator fuel inlet at all load ranges-3.5-7 in water column(0.87-1.74 kPa)for NG,10-12 in water column(2.49-2.99 kPa)for LP gas.For BTU content,multiply ft3/hr x 2500(LP)or ft3/hr x 1000(NG).For Megajoule content,multiply m3/hr x 93.15(LP)or m3/hr x 37.26(NG). Two-line plain text multilingual LCD Simple,user interface for ease of operation. Mode buttons:AUTO Automatic start on utility failure.Weekly,Bi-weekly,or Monthly selectable exerciser. MANUAL Start with starter control,unit stays on.If utility fails,transfer to load takes place. OFF Stops unit.Power is removed.Control and charger still operate. Ready to Run/Maintenance messages Standard Engine run hours indication Standard Programmable start delay between 2-1500 seconds Standard(programmable by dealer only) Utility Voltage Loss/Return to Utility adjustable(brownout setting) From 140-171 V/190-216 V Future Set Capable Exerciser/Exercise Set Error warning Standard Run/Alarm/Maintenance logs 50 events each Engine start sequence Cyclic cranking:16 sec on,7 rest(90 sec maximum duration). Starter lock-cut Starter cannot re-engage until 5 sec after engine has stopped. Smart Battery Charger Standard Charger Fault/Missing AC warning Standard Low Battery/Battery Problem Protection and Battery Condition indication Standard Automatic Voltage Regulation with Over and Under Voltage Protection Standard Under-Frequency/Overload/Stepper Overcurrent Protection Standard Safety Fused/Fuse Problem Protection Standard Automatic Low Oil Pressure/High Oil Temperature Shutdown Standard Overcrank/Overspeed(@ 72 Hz)/rpm Sense Loss Shutdown Standard High Engine Temperature Shutdown Standard Internal Fault/Incorrect Wiring protection Standard Common external fault capability Standard Field upgradable firmware Standard Rating definitions-Optional Standby:Applicable for supplying backup power for the duration of the utility power outage with correct maintenance performed.No overload capability is available for this rating. (All ratings in accordance with BS5514,ISO3046,UL2200,and DIN6271). 'Maximum kilovolt amps and current are subject to and limited by such factors as fuel BTU/megajoule content,ambient temperature,altitude,engine power and condition,etc.Maximum power decreases approximately 3.5%for each 1,000 ft(304.8 m)above sea level;and also will decrease approximately 1%for each 10°F(6°C)above 60'F(16°C). "Sound levels are taken from the front of the generator.Sound levels taken from other sides of the generator may be higher depending on installation parameters. 20/22/24 kW Features arid3 Benefits • 14 in(35.6 cm)flexible fuel line connector Listed ANSI Z21.75/CSA 6.27 outdoor appliance connector for the required connection to the gas supply piping. • Integral sediment trap Meets IFGC and NFPA 54 installation requirements. • Ability to view generator status Monitor generator with a smartphone,tablet,or computer at any time via the Mobile Link application for ' complete peace of mind. • Ability to view generator Exercise/Run and Total Hours Review the generator's complete protection profile for exercise hours and total hours. • Ability to view generator maintenance information Provides maintenance information for the specific model generator when scheduled maintenance is due. • Monthly report with previous month's activity Detailed monthly reports provide historical generator information. • Ability to view generator battery information Built in battery diagnostics displaying current state of the battery. • Weather information Provides detailed local ambient weather conditions for generator location. GENERAC® 20/22/24 kW Available Accessories _ Model# Product Description G007101-0 Battery Pad Warmer Pad warmer rests under the battery.Recommended for use if temperature regularly falls below 0*F(-16°C).(Not nec- essary for use with AGM-style batteries). G007102-0 Oil Warmer Oil warmer slips directly over the oil filter.Recommended for use if temperature regularly falls below 0°F(-18°C). G007103-1 Breather Warmer Breather warmer is for use in extreme cold weather applications.For use with Evolution controllers only in climates where heavy icing occurs. ' G005621-0 Auxiliary Transfer Switch The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load that may not be Contact Kit I needed.Not compatible with 50 amp pre-wired switches. G007027-0-Bisque Fascia Base Wrap Kit The fascia base wrap snaps together around the bottom of the new air-cooled generators.This offers a sleek,contoured appearance as well as offering protection from rodents and insects by covering the lifting holes located in the base. G005703-0-Bisque Touch-Up Paint Kit If the generator enclosure is scratched or damaged,it is important to touch up the paint to protect from future corrosion. The touch-up paint kit includes the necessary paint to correctly maintain or touch up a generator.enclosure. G006485-0 Scheduled Maintenance Kit Generac's scheduled maintenance kit provides all the items necessary to perform complete routine maintenance on a Generac automatic standby generator(oil not included). G007005-0 Wj-Fi LP Tank Fuel Level The W-Fj enabled LP tank fuel level monitor provides constant monitoring of the connected LP fuel tank.Monitoring the Monitor LP tank's fuel level is an important step in verifying the generator is ready to run during an unexpected power failure.Sta- tus alerts are available through a free application to notify users when the LP tank is in need of a refill. G007000-0(50 amp) Smart Management Module Smart Management Modules(SMM)are used to optimize the performance of a standby generator.It manages large elec- G007006-0 trical loads upon startup and sheds them to aid in recovery when overloaded.In many cases,using SMM's can reduce (100 amp) the overall size and cost of the system. G007169-0-413 LTE Mobile Links3'Cellular The Mobile Link family of Cellular Accessories allow users to monitor generator status from anywhere in the world,using G007170-0-Wi-Fi/ Accessories a smart phone,tablet,or PC.Easily access information such as the current operating status and maintenance alerts.Us- Ethernet ers can connect an account with an authorized service dealer for fast,friendly,and proactive service.With Mobile Link, users are taken care of before the next power outage. G007220-0-Bisque Base Plug Kit Base plugs snap into the lifting holes on the base of air-cooled home standby generators.This offers a sleek,contoured appearance,as well as offers protection from rodents and insects by covering the lifting holes located in the base.Kit contains four plugs,sufficient for use on a single air-cooled home standby generator. Dimensions & PCs Model UPC 637.6 mm 1218 mm [25.1 Inj I48.0 In] G007038 696471074185 G007039 696471074192 G007042 696471074208 G007043 696471074215 G007209' 696471071511 727.2 mm 128s In]G007210 696471084801M 4 0 0 848 mm 1232 mm [25.61n] [48.51n1 LEFT SIDE VIEW FRONT VIEW Dimensions shown are approximate.See installation manual for exact dimensions.DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. G E N E RACO Generac Power Systems, Inc. • S45 W29290 HWY.59,Waukesha,WI 53189 • geherac.com ©2022 Generac Power Systems,Inc.All rights reserved. All specifications are subject to change without notice. Part No.A0000937814 Rev.E 0 311 5/2 0 2 2 .- , EN 20/22/24 kW Switch Options 0007039.1,7G007039-3(20 kW) • Intelligently manages up to four air conditioner loads with no additional hardware. Model 0007043-10,0007043-11(22 kW) _ G007210-10(24 kW) • Up to eight additional large(240 VAC)loads can be managed when used in conjunction No.of poles 2 with Smart Management Modules(SMMs). Current rating(amps) 200 • Electrically operated,mechanically-held contacts for fast,clean connections. Voltage rating(VAC) 120/240,10 • Main breakers are rated for 80%continuous load. Utility voltage monitor(fixed)* -Pick-up 80% • 2-pole,250 VAC contactors. -Dropout 65% ' • Service equipment rated,dual coil design. Return to Utility* Approx.13 sec • Rated for both aluminum and copper conductors. ETL or UL listed Standard Enclosure type NEMA/UL 311 • Main contacts are silver plated or silver alloy to resist welding and sticking. Circuit breaker protected 22.000 • NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility. Lug range 250 MCM-#6 *Function of Evolution controller Dimensions Exercise can be set to weekly,bi-weekly,or monthly W, 200 Amps 120/240,1z Open Transition Service Rated Height Width Depth H1 H2 W1 W2 in 26.8 30.1 10.5 13.5 6.9 cm 67.95 76.43 26.67 34.18 17.5 HI Wire Ranges Conductor Lug. Neutral Lug Ground Lug 250 MCM-#6 350 MCM-#6 T 210-#14