Loading...
HomeMy WebLinkAbout52239-Z TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE THOLD NY SOU , BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 52239 Date: 09/08/2025 Permission is hereby granted to: Matthew R Lindsay 1170 Leslie Rd Cutchogue, NY 11935 To: install roof-mounted solar panels to an existing single-family dwelling as applied for. Premises Located at: 1170 Leslie Rd, Cutchogue, NY 11935 SCTM#97.-9-1 Pursuant to application dated 07/29/2025 and approved by the Building Inspector. To expire on 09/08/2027. Contractors: Required Inspections: Fees: SOLAR PANELS $100.00 CO-RESIDENTIAL $100.00 Total S200.00 Building Inspector� � TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone (631) 765-1802 Fax(631) 765-9502 ht!ps://www.soutligidtownny.gov Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only a PERMIT NO, Building Inspector: D ' LJ _5 �b Applications and forms must be filled out in their entirety.Incomplete applications will not be accepted. Where the Applicant Is not the owner,an BuIlding O p s e t Owners Authorization form(Page 2)shall be completed. -ro:wn Of Soutl10� Date: 7/15/2025 OWNER(S)OF PROPERTY: Name:Chr;bti^a Lindsay SCTM#1000- 097.00 - 09.00 - 001.000 Project Address: 1170 Leslie Road, Cutchogue, NY 11935 Phone#: (516) 356-1427 Email: clindsay@aol.com Mailing Address: 1170 Leslie Road, Cutchogue, NY 11935 CONTACT PERSON: Name: Michael Calise Mailing Address: 2941 Sunrise Hwy, Islip Terrace, NY 11752 Phone#: ( 631) 647-3402 Email: hppermitting@harvestpower..net DESIGN PROFESSIONAL INFORMATION: Name: Michael Dunn, R.A. Mailing Address: 256 Orinoco Dr, Brihtwaters, NY 11718 Phone#: ( 631) 665-9619 Email: Glenn@grahamassociates .com CONTRACTOR INFORMATION: Name: Harvest Power LLC Mailing Address: 2941 Sunrise Hwy, Islip Terrace, NY 11752 Phone#: (631) 647-3402 Email: hppermitting@harvestpower.net DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition❑✓ Alteration ❑Repair ❑Demolition Estimated Cost of Project: ❑Other $ 22,080.00 Will the lot be re-graded? ❑Yes ®No Will excess fill be removed from premises? Dyes ONO 1 PROPERTY INFORMATION Existing use of property: Residence Intended use of property: (no change) Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? Dyes ®No IF YES, PROVIDE A COPY. ®Check Box After Reading: The owner/contractor/design professional Is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By n name): Mi ael Calise ',Autborized Agent ❑Owner Signature of Applicant: Date: STATE OF NEW YORK) SS: COUNTY OF Suffolk ), Michael Calise being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Agent of Harvest Power LLC (Contractor,Agent, Corporate Officer,etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this 45nay of 20151-- Nota VNNWIA C.HAPSHE Notary Public,State of New York No.01 HA4928056 Qualified in Suffolk Cou ty {' { gr Teruo expires I, Christina Lindsay residing at 1170 Leslie Road Cutchogue, NY, 11935 do hereby authorize Michael Calise to apply on my behalf to the Town of Southold Building Department for approval as described herein.. na 7/16/2025 Owner's Signature Date Christina Lindsay Print Owner's Name 2 Building Department A tlic tion AUTHORIZATION (Where the Applicant is not the Owner) I� Christina Lindsay residing at 1170 Leslie Road,___._,__,_ (Print properly owner's name) (Mailing Address) lise Custogue NY 11935 do hereby authorize Michael a .....— (Agent) Harvest Power LLC to apply on my behalf to the Southold Building Department. 7/16/2025 (Owner's Si nature) (Date) Christina Lindsay (Print Owner's Name) CONSENT TO INSPECTION Christina Lindsay -,the undersigned, do(es)hereby state: Owner(s)Name(s) That the undersigned(is) (are)the owner(s)of the premises in the Town of Southold, located at 1170 Leslie Road, C tcho ue, NY 11935 which is shown and designated on the Suffolk County Tax Map as District 1000, Section 097.00 , Block 09.00 , Lot 001.000 That the undersigned(has)(have) filed, or cause to be filed,an application in the Southold Town Building Inspector's Office for the following: SOLAR Installation of a 5.98 kW Solar PV system with ( 13 ) REC460AA Pure-RX Roof mounted panels. That the undersigned do(es) hereby give consent to the Building Inspectors of the Town of Southold to enter upon the above described property, including any and all buildings located thereon,to conduct such inspections as they may deem necessary with respect to the aforesaid application, including inspections to determine that said premises comply with all of the laws, ordinances,rules and regulations of the Town of Southold. The undersigned, in consenting to such inspections;do(es)so with the knowledge and understanding that any information obtained in the conduct of such inspections may be used in subsequent prosecutions for violations of the laws,ordinances, rules or regulations of the Town of Southold. Dated: 7/16/2025 ( 1,gnature) Christina Lindsay (Print Name) (Signature) (Print Name) Graham Consultin COI- . 256 Orinoco Drive Suite,,A Bri htwa ers 11.71 Planning&Design (631)665-9619 July 23, 2025 Town of Southold Building Department 54375 Rt. 25 Southold, NY 11971 Re: Christina Lindsay Residence 1170 Leslie Road Cutchogue, NY Proposed 5.98 kWDC, 4.10 kWAC PV System To Whom It May Concern, Please be advised that I have analyzed the existing roof structure at the above-mentioned premises and have determined that it is adequate to support the additional load of the solar panels and a 140 mph wind load and 20 psf snow load without overstress, in accordance with the following: The 2020 New York State Uniform Fire Prevention and Residential Building Code; Town of Southold Local Code, Long Island Unified Solar Permit Initiative, (LIUSPI); and 2020 National Electric Code NFPA 70/2020 National Electric Code including ASCE7-16 If you have any further questions, do not hesitate to call. S a PHOTOVOLTAIC ROOF MOUNT SYSTEM fpl 13 MODULES-ROOF MOUNTED 5.98 kWDC, 4. 10 kWAC S�a39 1170 LESLIE RD, CUTCHOGUE, NY 11935, USA HAHAR 'RVESTPOWER ESTPOWER LLC 2941 SUNRISE HIGHWAY ISLIP SYSTEM SUMMARY: SHEET INDEX �. TERRACE,NY 11752 N 13-REC SOLAR REC460AA PURE-RX 460 MODULES GOVERNING CODES: tD t? TEL:(801)989-3585 O ( 2017 NATIONAL ELECTRICAL°CODE PV-0. COVER SHEET _�y`' ���_�°websi wwwhaivestnower.net (N) 13-ENPHASE IQ7X-96-2-US MICRO-INVERTERS 2020 NEW YORK STATE UNIFORM CODE PV-1 SITE PLAN WITH ROOF PLAN �;,�� �1LL (N)JUNCTION BOX 2020 NEW YORK STATE RESIDENTIAL CODE. PV-1.1 ENLARGED VIEW 40 (E)200A MAIN SERVICE PANEL WITH(E)200A MAIN BREAKER PV-2 ATTACHMENT DETAILS Ikr. n.v, I (N) ENPHASE IQ COMBINER BOX PV-3 THREE LINE DIAGRAM ,. PV-4 PLACARD&WARNING LABEL ! ! h PV-5 ADDITIONAL NOTES S � sr,4 PV-6+ SPEC SHEETS ,� � DESIGN CRITERIA: G y r^2Os `1 ROOF TYPE:-ASPHALT SHINGLE :' I`� � VERSION NUMBER OF LAYERS:—1 DESCRIPTION DATE REV, ROOF CONDITION:GOOD ROOF FRAME:-2"X6"RAFTERS @16"O.C. BLDG.PERMIT 07/22/2025 0 STORY:-1 STORY SNOW LOAD :-25 PSF WIND SPEED :-130 MPH WIND EXPOSURE:-D GENERAL NOTES: 1. INSTALLATION IN ACCORDANCE WITH MANUFACTURER RECOMMENDATIONS. ARRAY LOCATION PROJECT SITE 2. ENGINEER TO INSPECT PROJECT AFTER INSTALLATION AND CERTIFY COMPLIANCE. 3. PROJECT TO BE INSTALLED WITH CODE COMPLIANT wMacic RACKING INSTRUCTIONS FOR UNI-RAC SOLAR MOUNT PROJECT NAME SYSTEM. 4. FOLLOW BALLASTING SCHEDULE ON ROOF PLAN. enport O 0 5. HARVEST POWER, LLC.,THE SOLAR INSTALLATION CONTRACTOR,COMPLIES WITH ALL LICENSING&ALL 48 O O RELATED REQUIREMENTS OF THE GOVERNING. ,. z Ln p MUNICIPALITIES AND THE LOCAL ELECTRIC UTILITY 7_� 0 co C) J 6. THIS PROJECT WILL COMPLY WITH THE CURRENT NEC Spelt Z r O O t �. � W O W O REQUIREMENTS.INCLUDING ARTICLE 690 SOLAR SOUthold 'A ,Wan J J }- O U) PHOTOVOLTAIC PV SYSTEMS. Q W Z p D- LL :,.. +"� 7. THE ROOF WILL HAVE NO MORE THAN A SINGLE LAYER A �� I Z W LLI � �: O OF ROOF COVERING'IN ADDITION TO THE SOLAR ., i`z P�'CO IC� I— z EQUIPMENT. a se Y sAY VIE4� �� � � � � J 8. INSTALLATION WILL BE FLUSH-MOUNTED, PARALLEL - O TO AND NO MORE THAN 6.5"ABOVE ROOF .� ' " _ O 9. MAINTAIN A MINIMUM OF 18"CLEARANCE AT RIDGE Y^ ' A V AND AT ONE GABLE EAVE. s ='I 170 LeSIi@ Rd, 10. THIS DESIGN COMPLIES WITH 130 MPH WIND '� _ Xutdho U@ ICY U a. _ REQUIREMENTS OF THE RESIDENTIAL CODE OF N.Y.S �� "` ��4 + U Q Q AND ASCE 7-16. � 935, United States 11. WHEREVER THE ROOF PLAN DOES NOT COMPLY WITH '9UlattltUCk' 'Neer Suffolk Noyac ACCESS AND VENTILATION REQUIREMENTS OF THE ; �. SHEET NAME UNIFORM CODE, HARVEST POWER PROPOSES THAT )' x R COVER SHEET ALTERNATIVE VENTILATION METHODS WILL BE EMPLOYED. REVIEW AND APPROVAL SHALL BE AT THE Laurel " SHEET SIZE DISCRETION OF THE MUNICIPALITY IN WHICH THIS DOCUMENT HAS BEEN FILED. 0 ANSI B. 12. THE DESIGN PLANS COMPLY WITH THE 2020 NEW 1 1„ X 1 7„ YORK STATE UNIFORM FIRE PREVENTION AND RESIDENTIAL BUILDING CODE. 1 AERIAL PHOTO 2 VICINITY MAP SHEET NUMBER PV-0 SCALE: NTS PV70 SCALE: NTS �r PV-0 MODULE TYPE, DIMENSIONS & WEIGHT ROOF ACCESS AREA: SHALL BE LOCATED IN AREAS THAT DO NOT REQUIRE THE PLACEMENT OF GROUND NUMBER OF MODULES=13 MODULES �;,�\'� OVER OPENINGS SUCH AS WINDOWS OR DOORS;AND LOCATED AT STRONG POINTS OF MODULE TYPE=REC SOLAR REC460AA PURE-RX(460W) MODULES o- BUILDING CONSTRUCTION IN LOCATIONS WHERE THE ACCESS POINT DOES NOT ' MODULE WEIGHT=50 LBS/22.7 KG. Q� 'J) ) )) ` MODULE DIMENSIONS= 68"X 47.4"=22.38 SF QQ �) ) �\ CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS,WIRES OR SIGNS. UNIT WEIGHT OF ARRAY=2.23 PSF `- % HARVESTPOWER C /'�cJfi��' > \ HARVEST POWER LLC �� • [�t t J) `` 2941 SUNRISE HIGHWAY ISLIP �O / ( tJ j 1 TERRACE,NY 11752 ) \ _ R E f�0 a � TEL 8 1)989 3585 � / ` ��_ _ `� �., �6site:www.hanrestpower.net ' am (E) FENCE sj c , h (E)SHED p \ AAw r VERSION J / DESCRIPTION DATE REV. A� ��P ,� ` � •• / �Q` BLDG.PERMIT 07/22/2025 0 \% SEE ENLARGED VIEW ON PV-1.1 .� C �� %�) PROJECT NAME ` (E)GATE �\ u''' < O • 0 0, w a, w O F O U) cn '(r > (C �cc( J) Q ( SHEET NAME SITE PLAN WITH r J) or ROOF PLAN (E)TREE(TYP.) � `♦ (C � ( � �J) )(rC � � f� SHEET SIZE ANSI B 11" X 17" SITE PLAN WITH ROOF PLAN ;,��t,�v J)�/�� SHEET NUMBER Pv_1 V Q� MODULE TYPE, DIMENSIONS & WEIGHT (E) UTILITY METER NUMBER Or MODULES=13 MODULES oo� _ (E)200A MAIN SERVICE PANEL MODULE TYPE=REC SOLAR REC460AA PURE-RX(460W)MODULES ggFFss WITH (E)200A MAIN BREAKER MODULE WEIGHT=50 LBS/22.7 KG. q /' (INSIDE) MODULE DIMENSIONS= 68"X 47.4"=22.38 SF \ /f I UNIT WEIGHT OF ARRAY=2.23 PSF Q'�s� L,e 1 HARVESTPOWER HARVEST POWER LLC ISE RE 2941 TERRACEH Y 11752IGHWAY 1SLIP NE) s`*� EL:(801)989-3585 �� AA ebsrte.wwwharvest q er.net (N) ENPHASE IQ COMBINER BOA rrnn�V � r �' `9817 (E)CHIMNEY G'�dot E10 O) VERSION DESCRIPTION DATE REV. BLDG.PERMIT 07/22/2025 0 (N) V PVC CONDUIT — — — — RUN 7/8"ABOVE ROOF o � � : (N)JUNCTION BOX PROJECT NAME OO Q O Jp U O 2 p 000 O .� I- J W ow00 ROOF#1 Z W Z ti LL g J� (13) REC460AA PURE=RX(460W) J W O �- O • RAFTERS=2"X6"@16" O.0 �-- D O Z O o� 129°AZIMUTH, 21'TILT U� ti O O r O r FV_ Z .(13) ENPHASE IQ7X-96-2-US. MICRO-INVERTERS U Q Q ♦ SHEET NAME _. ENLARGED VIEW • SHEET SIZE :ANSI B 11" X 17" ENLARGEDVIEW � SHEET NUMBER SCALE: 1/8'.= 1'-0" �Pd�P� . . PV-1:.1 PV MODULES HARVESTPOWER HARVEST POWER LLC 'ID?4� UNRISE HIGHWAY ISLIP ��``� y' BRACE,NY 11752 � }�� -T,EN,801)989-3585 SEE ENLARGED VIEW „ O GY° its w harvest ower.net S C° 16 z� (E) ASPHALT SHINGLE ROOF 0X6 k- �[V 0 GENERAL NOTES: VERSION 1. RAILS TO BE INSTALLED TWO PER PANELS AS SHOWN IN DETAIL. DESCRIPTION DATE REV. 2. ALL PENETRATIONS TO BE MADE@ 48"O.C. BLDG.PERMIT 07/22/2025 0 3. BOLTS TOBE INSTALLED INTO RAFTERS. 4. MINIMUM 2.5"PENETRATION INTO WOOD FOR CODE COMPLIANCE. 1 ATTACHMENT DETAIL NOTE:_"ACTUAL ROOF CONDITIONS AND RAFTERS(OR SEAM)LOCATIONS MAY VARY. INSTALL PER MANUFACTURER(S) INSTALLATION GUIDELINES SCALE: NTS AND ENGINEERED SPANS FOR ATTACHMENTS." . END/MID CLAMP PV°MODULES PROJECT NAME OO O LQ p � o o � H L-FOOT z LV o u O J �' O d LL Z_ W Z 0 O t (E) ASPHALT SHINGLE ROOF _t W. 0 O F- O = o Z O J (N) UNIRAC ROOF/ DECK MEMBRANE o H SM STANDARD RAIL; _ .O o = O U Z el Q (E) 2"X6" RAFTERS @ 16" O.0 . U Q 2.5" MIN. EMBEDMENT SHEET NAME ATTACHMENT FLASH KIT PRO FLASHING DETAIL SHEET SIZE .. BUILDING STRUCTURE ANSI B 5/16" STAINLESS STEEL LAG BOLT 11" X 17" WITH SS EPDM BONDED WASHER, ATTACHMENT DETAIL (ENLARGE VIEW) 2-1/2" MIN. EMBEDMENT. SHEET NUMBER 2 SCALE: NTS PV-2 (1�) REC SOLAR REC460AA PURE-RX(460W) MODULES BILL OF MATERIALS (13) ENPHASE IQ7X-96-2-US MICRO-INVERTERS EQUIPMENT. QTY DESCRIPTION : (01) BRANCH OF 7 MODULES & SOLAR PV MODULE 13 REC SOLAR REC460AA PURE-RX(460W)MODULES (01) BRANCH OF 6 MODULES CONNECTED IN PARALLEL PER BRANCH MICRO-INVERTER 13 ENPHASE IQ7X-96-2-US MICRO-INVERTERS JUNCTION BOX 1 600V,55A MAX,4 INPUTS,MOUNTED ON ROOF FOR WIRE&CONDUIT TRANSITION SYSTEM SIZE:- 13 x 460W= 5.98 kWDC INTERCONNECTION COMBINER BOX 1 ENPHASE IQ COMBINER BOX HAIRVESTPOWER HARVEST POWER LLC 13 x 315VA=4.10 kWAC 120% RULE- NEC 705.12(B)(2)(3)(b) `� 2941 SUNRISE HIGHWAY(SLIP TERRACE,NY 11752 UTILITY FEED + SOLAR BACKFEED :EL TEL:(801)989 3585 c�. �i ebsite:www.harvest ower.net 200A+25A=225A �� G `0 BUSS RATING x 120% ') o n�( 200A x 120/o =240A 9'817 O� O- �i!E\N VERSION DESCRIPTION DATE REV. BLDG.PERMIT 07/22/2025 0 7 MICRO-INVERTERS IN BRANCH CIRCUIT#1 BI-DIRECTIONAL UTILITY METER ............... .........._.......... ........ - -- - — 1-PHASE,3-W, ...................._...... _._._._......_ .......__.._._. - — — 120V/240V,60Hz • • • _.._._._ ....._..._..._....._...... ........._............. _._. I --- 1 (N)ENPHASE COMBINER BOX ti 1 ti I ti I I L I 6 MICRO-INVERTERS IN BRANCH CIRCUIT#2 (E)200A MAIN SERVICE PANEL j W/(E)200A ut -- - 7T — — -- 15A MAIN BREAKER ............._ (N)JUNCTION BOX (TOP FED) PROJECT NAME ._.......................... __._..._.._........._... ....._._ _. ._._ _... ---- O 777 20A (N)25A/2P PV �/ = O J L1 L1 200A cl ti I 'V 1 1 20A. O BREAKER ------------- ----- -, � � O _ 1 C) ch O I L1 L1 \ z O UI (13)ENPHASE I.Q7X-96-2-US 1 M' IQ _D W 00 U) 0 1 ENVOY J MICRO-INVERTERS i i----------------- ------==------------i z5A/ U) Z 00 LL a. Q TERMINATOR CAP ON LAST CABLE _--� i �--- O O Z L----==------- CONNECTOR Q-CABLE(TYP) i _� I` c) J (3)#6 BLK RED WHT THHN i m O I"- 0 (2)Q-CABLE (4)#10 AWG THWN-2 (1)#6 THHN STRANDED V _ ~ (1)PV 6 BARE CU GND (1)#6 THHN STRANDED GREEN GROUND IN 1"PVC '1 GREEN GROUND CONDUIT RUN �, EXISTING GROUNDING U I— Z IN 1"PVC CONDUIT + SYSTEM V Q Q SHEET NAME THREE LINE DIAGRAM SHEET SIZE ANSI B 11" X 17" THREE LINE D IAG RAM SHEET NUMBER SCALE: NTS PV-3 4+� ' A I EL_ ECTRICAL SHOCK HAZARD PHOTOVOLTAIC SYSTEM SOLAR P S STEM EQUIPPED ' COMBINER PANEL SIDESENERGIZED WITH RAPID SHUTDOWN TERM MAY INALS ON LINE GIZ LOAD DO NOT T ADD LOADS HARVESTPOWER ENNERGIZED IN HARVEST POWER LLC THE OPEN POSITION LABEL LOCATION: 2941 SUNRISE HIGHWAY ISLIP PHOTOVOLTAIC AC COMBINER(IF TERRACE,NY 11752 APPLICABLE). R E TEL:(801)989 3585 LABEL LOCATION: INVERTER(S),AC DISCONNECT(S),AC 3° TURN RAPID SHUTDOWN , _ .Pw�ste:www.narvest ower.net COMBINER PANEL(IF APPLICABLE). SWITCH TO THE"OFF" °v PANE sR�� �•� POSITION TO SHUT DOWN 'z� PV SYSTEM AND REDUCE SHOCK HAZARD IN THE RAPID . ARRAY. ^® o 7 Q� SWITCH R SOLAR P ���r��� �UV VERSION • a�f�`•`•DESCRIPTION DATE REV. SYSTEMLABEL LOCATION: BLDG.PERMIT 07/22/2025 0 ON OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE LABEL LOCATION: DISCONNECTING MEANS TO WHICH THE PV SYSTEMS UTILITY SERVICE ENTRANCE/METER,INVERTER/DC ARE CONNECTED. DISCONNECT IF REQUIRED*BY LOCAL AHJ,OR OTHER LOCATIONS AS REQUIRED BY LOCAL AHJ. POWER SOURCE OUTPUT CONNECTION DO NOT RELOCATE THIS PROJECT NAME OVERCURRENT DEVICE LABEL LOCATION: (a O p ADJACENT TO PV BREAKER AND ESS }- CO J OCPD(IF APPLICABLE). Q U7 O Q BUILDING SUPPLIED BY UTILITY c o co o J GRID AND PHOTOVOLTAIC z o C� SYSTEM J } o U • SOURCEWER (N)PV MODULES I-- O z W U) ti (D 8O J LABEL LOCATION: U) O O O INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, LLIAT = _ ON EACH V ABOVE PENETRATIONS,ERY JB PULL BOX CONTAINI G DC CIRCUITS. V F— Z = r- Q U Q PHOTOVOLTAIC AC DISCONNECT SHEET NAME �. .. PLACARD & NOMINAL O. 40 VAC WARNING,LABELS LABEL LOCATION: SHEETS IZE AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF (E)UTILITY METER ANSI B INTERCONNECTION. (E)MAIN SERVICE PANEL (INSIDE) 11" X 17" (N)COMBINER BOX LABEL LOCATION: SHEET NUMBER POINT OF INTERCONNECTION (PER CODE:NEC690.56(B),NEC705.10,225.37,230.2(E)) PV_ 1. EACH MODULE TO BE GROUNDED USING THE SUPPLIED CONNECTION POINT PER • MANUFACTURER'S REQUIREMENTS. ALL SOLAR MODULES, EQUIPMENT, AND METALLIC COMPONENTS ARE TO BE. BONDED. IF THE EXISTING GROUNDING HARVESTPOWER ELECTRODE SYSTEM CAN NOT BE VERIFIED OR IS ONLY METALLIC WATER PIPING, HARVEST POWER LLC IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSTALL A SUPPLEMENTAL 2941TERRRACEEHIGHWAY Y117 ZISLIP GROUNDING ELECTRODE. -m_ TEL:(801)9803585 �' %s°� �ebsite.—.harvestpowernet 2. ALL PLAQUES AND SIGNAGE REQUIRED BY THE LATEST EDITION OF NATIONAL ELECTRICAL CODE. LABEL SHALL BE METALLIC OR PLASTIC, ENGRAVED ORY. MACHINE PRINTED IN A CONTRASTING COLOR TO THE PLAQUE. PLAQUE SHALL BE UV RESISTANT IF EXPOSED TO SUNLIGHT. bF ' �0' 0 � 8 17 3. AC CONDUCTORS SHALL BE RUN IN EMT AND SHALL BE LABELED, "CAUTION AC 6� C RIPTION ERSIIO E REV. CIRCUIT" OR EQUIV. EVERY 5 FT. BLDG.PERMIT 07/22/2025 0 4. EXPOSED NON-CURRENT CARRYING METAL PARTS OF ELECTRICAL EQUIPMENT SHALL BE GROUNDED IN ACCORDANCE WITH 250.134 OR 250.136(A). 5. CONFIRM LINE SIDE VOLTAGE AT ELECTRIC UTILITY SERVICE PRIOR TO CONNECTING INVERTER. VERIFY SERVICE VOLTAGE IS WITHIN INVERTER VOLTAGE OPERATIONAL RANGE. 6. OUTDOOR EQUIPMENT SHALL BE NEMA-3R RATED OR BETTER. PROJECT NAME 7. ELECTRICAL CONTRACTOR TO PROVIDE CONDUIT EXPANSION JOINTS AND < 0 0 ANCHOR CONDUIT RUNS AS REQUIRED PER NEC. }- o Oz 8. ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL M o .: (m MEANS DESIGNED AND LISTED FOR SUCH USE,-AND FOR ROOF-MOUNTED z w � a w O SYSTEMS, WIRING MUST BE PERMANENTLY AND COMPLETELY HELP OFF OF THE J — O U) co ROOF SURFACE. NEC 110.2 - 110.4 / 300.4 Q U) Z o 0- �'- z J W r-- � 0 . 1- oZo _ Z 9. ALL ROOF PENETRATIONS MUST BE FLASHED. SIMPLY CAULKING DOES NOT (A SUFFICE. E O o O _: U z U Q Q SHEET NAME ADDITIONAL NOTES SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-.5 1HP . . . . . . HARVESTPOVI/ER 294 LIP . .. . ARVEST POWER LL� � � � O � � � � RK 1 SUNRISE HIGHWAY ISSOLARrS:MOST TRUSTER � �-� TERRACE,NY 11752 REC 9ti:_ TEL:(801)989 3585 TRUSTEDSOLAR'S MOST - �� `�� '' � site:wwwharvestpower.net GE ERA t * ' ALP ® _ 88half-cutbifacialRECheterojunctioncells; r- F 4 { c CellType L withgapless nology ' - t� t ":�, ' ti DAT u - --- - -- -- tech Tt r C - - - - - ass 0.13 in.so(arglass with anti=reflective surfacetreatment J nik; .-. ,- - ... ... GI _ .. ... inaccordance with EN12150 Backsheet Highlyresistantpolymer(Bladc) Wjy : _ _ Frame__- _- - ---- Anodiedaluminum(Black)., 1 B 4-a 4 ass diodes, unction ox 4Rn E RX , 5ERIE5 IP68 rated in accordance with IEC 62790 + StaubliMC4PV-KBT4/KST4(12AW15) _ S 1 rl 1 Connectors in accordance with lEC6285ZIP68 only when connected • jf Ecd 11� VERSION 12AWGsolarcable.66.9in.+669in. DESCRIPTION DATE REV. r D ,�sR in accordance with ..x m - Cable j'w r j ❑ BLDG.PERMIT 07/22/2025 0 r°�TASHEET _ptEriSld _ _ _ _.�� _ r� Weight -'50 lbs t i�to anaau ai Origin ., MadeiRSingapore' 0 t ELECTRICALD TA PR; 1[TC90 F e R CERTIFICA TONS Power Output-Px(Wa 450 460 470 IEC61215:2021(IEC617302016;UL61730 Watt ClassSorfing-(W) 0/+10 0/+10 0/+10 1S011925-2_ Ignitabiiit jjEN13501-1ClassE) IEC 62716 Ammonia Resistance Nominal Power Voltage-V,,(V), 54.3 54.9 $5.4 IEC61701 Saft:Mist(SM6) a Nominal Power Current-1,;ii;r(A) 829 8.38 8.49 IEC61215:2016 Hailstone(35mm) N -- UL617_30 FireType2 Open Circuit Voltage_V«(V) 65in -.6 65.8 65.9 15014001;1-69001;IEC45001;IEC62941 Short Circuit Current-1.(A) 8.81, L8.88 8.95.. PowerDensity(W/ft') 20.1 205 21.0 0 °n C take�uvay in Panel Efficiency(a/o) 21.6 221 226 ``wmaJ ` PROJECT NAME Power Output 343` 350 358 _ CURRENT I.- Nominal Power Voltage-V_(V) 512 51.7 522 U) 0 Q . MODULE Z Nominal Power Current (A) 6.70 6.77 6.86 }. 0 J COMPATIBLEOpen Circuit Voltage 61.8 62,0 62.1 Q _ O 0 '^ Lf� — -- ---- -- Short Circuit Cur rent-Iu(A) 7.11 7.17 723 VAR TY vJ - _ VaWesatstaMardiestmndrtlons ISM atr—AMlS,trradlancelODOW/ma,teriperanve7TF(2 1ba'sedanalxWuni �read:abamleranaofo .va�lffz3% _ ____ _Standard RECPr.Trust Q wltHnonewaftdass.Namuwrmamde r�tUstempe a(NMOTa'rmassAMls.iradia�aooW/m?temperawreWF,( w,ndspecd33ft/s(lm/s)),whemm :Installedbyan REC No : Yes Yes.' O I mmcatesmenamu.mpmrerdass(a„„7atCacwe Certified Professional Z 0 W IMUMRATNGS* TEMP TORE TINES* 5ystem5ze All c25kW 25-500kW J W T O O — — - ProductWarran rs :20 25 25 J OperationalT -perature 40°F-185°F Nominal Module,Operating ty(Y ) - a S stemVolta a 1000V 44°C+2°C PowerWarranty(yrs) 2S 25 25 7Q U) Z LL. y_— -S- Temperature L W W ~ O r s ;,�,r, y r��-°,,,,-,L•�,t:r °x'- Maximum Test Load(front) 7000Pa(1461b/ft') - pe tF -- LaborWarranty(yrs). 0 .'25 10 TemperaturemeffidentofP -024%/K o 1 4a_ ;T P e,r r i �R,• y Maximum TestLoad(rear) 4000Ps(83.41b/ft�) -- ffi — -' PowerinYearl 98% 98% 9_8% N --( -t_ _'n a- - _ - -- ------ -- - Tempera urecoeffide_Mof_Vm - -024_%/_K ---- m 7 x �-..� �s- `� xy Max Series Fuse Rating 25A TemperaturecoefficientofI 0.04a/o/K Annual egradatio_n 0.25% 0.25% 0.25% 'n. C) Z — L _.—. __._ x —__. ---------• Y' W t _..------_ .. _ _--_ ----, _25A etemptatdremeffic[mmsrnedaieuivuvdues PowerinYear25 92% 92% 92% V .-^�� • Max Reverse � � O J .-q '; -^_� �• - f%+<^ri` •Seelrstalladon nam,al forrwundnglr6lnatlorR _ rY C) REC v aT st warranty p nea o tors REe is rn:aned aEe eenlfied /v�/J r Desipilmd-Testload/I.S(safetyfaaar) Solar Professbral a�II)p nave been p kfired Nebl stay Mth REC o LJ— �� OEiIVERYINFORMA.' ON p' reg r sublea to5ystem Sim aMfuMercmrGnms.Seer smnfardetalls � O = O'?: Panels per Pallet 33 to �.r !=- Panels per 40frGP/high z '^-^' r _ cubecontaitier' .594(18Paliets). U LO UGH 8 HA OR w — ` Q Available from: Panels per 53fttruck 792(24Pallets) Typical P a T fcallawirradiance performance r, : a. -e i ; V - . -- '-- --------....i----- ---! �' EFFICIENCY SHEET NAME - i w ... --- . ,% P.CO EFF■MAX _ � -,-�; ; ` _ SPEC SHEET HETEROJUNCTION TECHNOLOGY 92% POWER IN YEAR Founded'1.1996,REC Group is an international pioneeringmiarenergycomp*dedtcatedto empoweringcomumerswith clear,affordable .REC Solar PTE.LTD. ® �^� solarpower.AsSoWs Mostrnisted,REC is commuted to high quality,innovation,and a low cattion footprint in the solarmateriaisand solar 207uas SouthAve.14 rn panelsitmmufaves.Headquarteredin Norwaywith operational headquarters In Singapore REC also hasregional hubs'.NorthAmeriq Singap L ore637312 SHEET SIZE Europe,andAsia-Pacific post@recgroup.com wmvrecgroup.com ANSI B 11" X 17" SHEET NUMBER Pv-6 FP Data Sheet IQ7X Microinverter HARVESTPOWER Enphase Microinverters HARVEST POWER LLC Region:AMERICAS INPUT DATA.(DC) IQ7X-96-2-US 2941 SUNRISE HIGHWAY ISLIP TERRACE,NY Commonly.used module pairings'_ 320W-460W -_ -_ �___-_ ---_' �`� F TEL: 1)989-3 85 Module compatibility 96ceILPVmodules ' ''p y _ r 1-°,.�= ewe sde�lnvw.harvestpowernet Maximum input DC voltage — 79-SV Pe i --- -- - -- -- - -- ------- ------ - ------ - Peak power tracking voltage 53V 64V /'� - _ -' - _ __ . _ _.Operating range _ 25V 79.SV.. Min/Max startxoltage - -- -�-- 33V/79.5V Ari e I Max DC short circuit current(module Isc) -10A IQ7X Mieroinverter The high-powered,smart grid-ready overvoltageclass DC port -- -- II -- -� -- -- -- --- _---- -�f� ��. IQ7X Microinvettet dramatically simplifies the DC port backfeed current- - .0A -- -_-- --- - -- ----_ - - --- -IN7, , 1� PV array configuration 1 x 1 ungrounded array;No additional DC side protection required; — 01 p installation process while achieving the highest 2g AC side protection requires max 20A per branch circuit system efficiency for systems with 96-cell modules. 0UTPUT:DATA(AC) -_ I Peak output power 320VA � VERSION a IV E ER Part of the Enphase Energy System,the IQ7X ---.-----_--.____ ----._ _----- -3-1-5 VA - -_.- -. _-- ._- - ---- _ ___ ___-_ - --- - - _-- _ --. P 9Y Y Maximum continuous output power 315VA DESCRIPTION DATE REV. Microlnverter integrates with the IQ-Gateway, 1-Nominal(L L)voltage/range2 -' 24OW211-264V 208W183-229V 1 9 Y l_ BLDG.PERMIT 07/22/2025 0 IQ Battery,and the Enphase Installer App monitoring rL D--- ----- --- -'— ' - -- ----- --� Nominal frequency - 60 Hz. and analysis software. Extended frequency range 49-68 Hz AC short circuit fault current over 3 cycles 5 8 Arms The IQ Series Microinverters extend the reliability -__. -----__.___.__.___ ...... . . ..... _._ -_ Standards set forth by previous generations and overvoltage Mass do port, undergo over a million hours of power-on testing, AC port backfeed current 18 mA -� ----------- - --- - ---- - --- = --- -------- Power factor setting 1-0- enabling Enphase to provide an industry-leading Power factor(adjustable) 0.85 leading...0.85 lagging �- warranty of up to 25-years. EFFICIENCY' @240VAC @Zg8VAC CEC weighted efficiency r i 97.5% 97.0% I MECHANICAL DATA ' Ambient temperature range _•401Cto+60°C . Relative humidity range 4%to 100%(condensing)Easy to Install - .Connector type(IQ7X-96-2-US) MC4(or Amphenol H4 UTX.with optional Q-DCC-5 adapter)- PROJECT NAME --— - - -— ------ -------- --- Dimensions(WxHxD) 212 min x 175 mm x 30.2 mm(without bracket) _ Lightweight and simple Weight 1-08 kg(2 38 lbs) < • Faster installation with improved,lightertwo-wire cabling Cooling - _-Nat fans - _ -- _ - _ _ ((�, O Q Natural convection No ti roved for wet locations r • Built-in rapid shutdown compliant(NEC 2014,2017&2020) Yes :,- - > O O Pollution degree PD3 'G..'L" r Enclosure ' - Y Class II double-insulated,corrosion resistant polymeric enclosure - - vJ CC) O Efficient and Reliable Environmental category/UV exposure rating NEMA Type 6/outdoor 0 O O J f-- �- • Optimized for high powered 96=cell*modules FEATURES • Highest CEC efficiency of 97,5% I'Communication _- Power Line Communication(PLC) _ ____-_ - ; Z W O W O Monitoring Enphase:InstallerApp and.monitoring:options O U) U) • More than a million hours of testing Compatible with IQ Gateway c) LL --- -- 9- - - - - -- - - - -- • Class 11 double-insulated enclosure Disconnectin means- The AC and DC connectors have been evaluated and approved by UL for use as the load break —j =disconnect required by NEC 690. _ UJ 0 •. UL listed ----- - - - --- - --- ------- -- --._T _ .. __.. _. z J W O Compliance CA Rule 21(UL 1741-SA),IEEE 1547:2018(UL 1741-SB,3'd Ed) Z) O Z p HEI Rule 14H SRD 2.0. (n UI O J 3 • UL 62109-1,FCC Part 15 Class B,ICES-0003 Class B, O Smart Grid-Ready CAN/CSA-C22.2140.107.1-01 r Q p I-- O • Complies with advanced grid support,voltage and frequency This NEC 2017,rct is UL Listed as PV Rapid Shut Down Equipmentand and NEC 2020,sect on 690.12 nd C221Q201 conforms 5 Rule 64-218Rapid Shu down of PV 2 ride through requirements Systems,for AC and DC conductors,when installed according manufacturer's instructions, w_ . • Remotely updates to respond to changing U F_ Z .,.._ grid requirements Q �k V • Configurable for varying grid profiles Q Meets CA Rule 21(UL 1741-SA)and 1.Pairing PV modules with wattage above the limit may result in additional clipping losses.Seethe compatibility calculator U IEEE 1547:2078(UL 1741 SB,3"'Ed.) at https-//link-enphase-com/module-comoatlbllity- 2.Nominal voltage range can be extended beyond nominal if required by the utility. SHEET NAME 3.Limits may vary.Refer to local requirements to define the number of microinverters per branch In your area. log M. *The IQ7X is required tosupport 96-cell modules. To learn more about Enphase offerings,visit enphase.com SPEC SHEET To learn more about Enphase ps,vi sit isit en hase.eom @ 2022 Enphase Energy All rights reserved.Enphase,the Enphase logo,I.Q7,IQ7+,IQ Battery,Enphase Installer.App,IQ Gateway, IQ7X-DS-0099-EN-US-12-2-022 g E N P H AS E. and other trademarks or service names are the trademarks of Enphase Energy,,Inc. \� ` E N P H AS E. SHEET SIZE IQ7X-DS- EN-EN-US-12-27-2022 ANSI B 11" X 17" SHEET NUMBER PV-7 1 ' ° SOLARMOUNT ::� U N I RACHARVEST POWER LLC TERRACE,NY 11752 :. 1 1 I 1 1 1 1• 1 .11 I I• I BETTER DESIGNS 1' � 'I 1 •. •. 1 I ' I is 1 I I • I I � ���� � TRUST THE INDUSTRY'S BEST DESIGN TOOL CONCEALED UNIVERSAL a 1 I I ' 1 1 1 1 •. 1 Start the design process for every project in our U Builder on line design tool. ENDCLAMPS ICs a great way to save lime and money. r ' 1 101K•. BETTER SYSTEMS ONE SYSTEM-MANY APPLICATIONS Quickly set modules flush to the roof on steep pitched roofs.Orient a large variety of modules in Portrait of Landscape.Tilt the system up on flat or love slow roofs. END CAPS INCLUDED ��- m Components available in mill.clear.and dark finishes to optimize your design financials and aesthetics. WITH EVERY ENDCLAMP --- BETTER RESULTS MAXIMIZE PROFITABILITY ON EVERY JOB CONCEALED Trust Umrac to help you minimize bolh system and labor costs from the lime the lob is UNIVERSAL quoted to the time your learns gel off the roof.Faster installs.Less Waste.More Profits. CLAMPS UNIVERSAL SELF :PUNIRAC BETTER SUPPORT STANDING MIDCLAMPS 25WORK WITH THE INDUSTRIES MOST EXPERIENCED TEAM Professional support for professional installers and designers.You have access to - PROJECT our technical support and training groups.Whatever your support needs.we've got YEAS1 I ' I OPTIONAL you covered.Visit Uniric.rorn/solarmounlfor more inlormation. ,� II 1 l 1 FRONTTRIM fUILSYSUM WA ITY _ . •RHAf U-BUILDER ONLINE DESIGN TOOL SAVES TIME&MONEY 1• 1 1 • " ( Visit rlesf m unuac,cim • © LU N UL2703SYSTEMBONDING&GROUNDING v.c3c-; g •MECFIANICpLlOADING i s FIRCCLASSIFICATION - . : • 6� = �F UNIRAC CUSTOMER SERVICE MEANS THE HIGHEST LEVEL OF PRODUCT SUPPORT z 'r' UNMATCHED CERTIFIED ENGINEERING BANKABLE DESIGN PERMIT 1 1 'Il 1 I 1 I I I1. I II I I I • I I I 1 I EXPERIENCE QUALITY EXCELLENCE WARRANTY TOOLS DOCUMENTATION TECHNICAL SUPPORT CERTIFIED QUALITY PROVIDER BANKABLE WARRANTY Unirac•s technical support[earn is dedicated to answering Unirac is the only PV mounting vendorwith ISO Don't leave,your project to chance.Umrac has the questions&addressing issues in real time.An online certifications for 9001:2008.14001:2004 and DIISAS financial strength to back our products and reduce your risk. SHEET NAME THE PROFESSIONALS' CHOICE FOR RESIDENTIAL RACKING stamydf eacumendsecniing atashootsgre greatly f800120m.andfhmeanswes deliver the hionsdemohest nstrt Have peace ofrmty.SOL RMOU Tiscre overedbrod5year slampedlotlersandlochnicaldatasheotsgreally for fit.formand(unction.Thesecorlificationsdemonsirate exceptional gualily.SOLARMOUNTisroueredhya25year SPEC SHEET simplifies your permilling and project planning process. our excellence and commitment to first class business practices. Ifni[ed product warranty and a5 year limited finish warranty. SHEET SIZE 11111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111 BEST INSTALLATION EXPERIENCE-CURBAPPEAL•COMPLETE SOLUTION•UNIRACSUPPORT ANSI B ENHANCE YOUR REPUTATION WITH QUALITY RACKING SOLUTIONS BACKED BY ENGINEERING EXCELLENCE AND A SUPERIOR SUPPLY CHAIN FOR QUESTIONS OR CUSTOMER SERVICE VISIT UNIRAC.COM OR CALL (505) 248-2702 ,. ,;;, , ,.•; FOR QUESTIONS OR CUSTOMER SERVICE VISIT UNIRAC.COM OR CALL (505) 248-2702 4 FP Unirac state Letter-NY HARVESTPOWER Tectonic, Tectonic Tectonic WO#:12557.24 HARVEST POWER LLC August 12,2024 2941 SUNRISE HIGHWAY ISLIP F9[FI[A�SDIVT,ONS,!}[(c(IDN.l5fFV1[F. PU[TI[A(SOWtIDNl.(Ii[P;:ONk[SCri K4 .4 E,NY 11752 (8g1)989-3585 August 12,2024. ■ Metal Roof:Standing Seam Attachments, PM-9000s, and PM Adjust Slotted , ; nwebsiteJwww.ha[vesfpower.net Tile Roof:Solar hooks, Flashkit Tile Replacement(TR) ,, '10_ Unirac M Attn: Engineering Services Department The U-Buil.der Tool should.be used under the responsible charge of a registered4 n 1411 Broadway Boulevard NE professional engineer required by the authority having:jurisdiction. The design tools r ; k 'A Albuquerque, NM 87102-1545 and Unirac do not evaluate the existing roof structure,or the PV panels themselves. ,� TEL: (505)242-6411 See the construction and installation drawings and manuals for additional information provided by Unirac, RE: ENGINEERING. CERTIFICATION LETTER FOR THE UNIRAC SOLARMOUNT (SM) d , v ROOF PV PANEL SUPPORT SYSTEM Sincerely, ERsloN NW -� 4�FE DESCRIPTION DATE REV. STATE: NEW YORK Tectonicr,P �� A- (�'� y0,A BLDG.PERMIT onzzrzozs o TECTONIC WORK ORDER#:12557.25 off qc �.. The Unirac SOLARMOUNT(SM) Photovoltaic Panel Support System is a proprietary : framed photovoltaic panel support system that is installed on a roof: Tectonic z' Engineering .Consultants, Geologists & Land Surveyors, D.P.C. (Tectonic) has reviewed the SM design methodology along with the U-Builder tool; a Unirac.online design tool. The review included the following SM products, SM Light, Heavy Duty, SIONP, 08/12/2024 and Standard rail with both the standard and pro hardware. Antonio A. Gualtieri;P.E. Tectonic has determined that the design is a rational approach and follows the Executive Vice President structural requirements of the following reference documents: Codes/Standards: • 2020 Building Code of New York State. PROJECT NAME • 2018 International Building Code by International Code Council. Q 0 • ASCE/SEI 7-16 Minimum Design Loads for Buildings and Other Structures, by U) 0 0 American Society of Civil Engineers with provisions from SEAOC PV-2-2017. 0 = Q O • 2020 Aluminum Design Manual;by Aluminum Association. 0) � p _ p CI 0 F- This letter certifies that the structural analysis of the racking members,connections; 0Y (� Z) and components directly related to Unirac's system are in compliance with the z W 0) W O above codes. The design methodology is acceptable under components and _J J 0 W U) cladding loads associated with the building's roof structure when the system is Q (q Z o a- LL. installed in accordance with manufacturer specifications. If the loading criteria does Z W ti } O not meet Unirac's specifications, owner shall contact Unirac for a site-specific W o I-- z certification. (n o� O 0 .I � O 0 ? O Attachments approved for the SM system to the structure include the following = and is installed per Unirac's U-Builder report and installation guides: _ Z) 12 Q ■ Shingle Roof: L-Foot Flash kit Pro, Standoffs, Flashloc Comp; Flash Lod Duo, 0 Q and Flash Kit Pro SB SHEET NAME Project Contact Info Project Contact Info SPEC SHEET 1279 Route 300 I Newburgh,W 12550 1279 Route 3OO I Newburgh,W 12550 845.567.6656 Tel 1845.567.8703 Fax 845.567.6656 Tel 1845.567.8703 Fax SHEET SIZE tectonicengineering.com tectohlcengineering.com page 2 of 2 Equal Opportunity Employer Equal Opportunity Employer ANSI B 11" X 17" SHEET NUMBER PV-9