Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
49543-Z
�of so�o4uryo`o Town of Southold * * P.O. Box 1179 0 53095 Main Rd orm Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 46263 Date: 06/24/2025 THIS CERTIFIES that the building DECK Location of Property: 400 East Rd Mattituck, NY 11952 Sec/Block/Lot: 106.-3-2 Conforms substantially to the Application for Building Permit heretofore,filed in this office dated: 06/26/2023 Pursuant to which Building Permit No. 49543 and dated: 08/03/2023 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy-for which this certificate is issued is: Deck addition and HVAC system to existing single-family dwelling as applied for. The certificate is issued to: Nako Rizo , Sose Rizo Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: 49543 6/18/2025 PLUMBERS CERTIFICATION: i tho ' ed ign ture o�SUFFa'u TOWN OF SOUTHOLD �� ay BUILDING DEPARTMENT y z TOWN CLERK'S OFFICE "� • SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 49543 Date: 8/3/2023 Permission is hereby granted to: Rizo, Nako 19-19 21 st Rd Long Island City, NY 11105 To: construct deck addition to existing single-family dwelling as applied for. At premises located at: 400 East Rd, Mattituck SCTM #473889 Sec/Block/Lot# 106.-3-2 Pursuant to application dated 6/26/2023 and approved by the Building Inspector. To expire on 211/2025. Fees: SINGLE FAMILY DWELLING-ADDITION OR ALTERATION $286.40 CO-ADDITION TO DWELLING $50.00 Total: $336.40 Building ector pF SOUr��l 0 Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 G • Q Southold,NY 1 1 97 1-0959 BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Nako Rizo Address: 400 East Rd city:Mattituck st: NY zip: 11952 Building Permit#: 49543 Section: 106 Block: 3 Lot: 2 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: License No: SITE DETAILS Office Use Only Residential X Indoor X Basement Solar Commerical Outdoor X 1 st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser 2 Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect 2 Switches 4'LED F:1 Exit Fixtures Sump Pump Other Equipment Notes: 2 Samsung Mini-Splits, 7 Heads, (2) 20 Amp 2 Pole Breakers Inspector Signature: Date: June 18, 2025 S.Devlin-Cert Electrical Complia ce F rm(9) OF SOUTH°� # TOWN OF SOUTHOLD .BUILDING DEPT. 'gum, ' 631-765-1802 � (4� q INSPECTION [ ] FOUNDATION 1 ST/ REBAR . [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] I ULATIO CAULKING [ ] FRAMING/STRAPPING [ FINAL . [ ] FIREPLACE & CHIMNEY [ . ] FIRE SAFETY INSPECTION ] FIRE RESISTANT CONSTRUCTION [ ] -FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL" REMARKS: ` L �S A t/ Cam. Rykc� DATE INSPECTOR �o,*pE SOGIHp� # TOWN OF SOUTHOLD BUILDING DEPT. `ycou 631.765-1802 q(! INSPECTION [ FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ]' RENTAL REMARKS: Kv f"- DATE INSPECTOR OF SOGIyo<o # # TOWN OF SOUTHOLD BUILDING.DEPT. co 765-1802 INSPECTION [ ] FOUNDATION 1ST [:. ] ROUGH PLBG. [ ] FO NDATION 2ND [ ] IN LATIOWCAULKING [ FRAMING/STRAPPING [ FINAL [ ] FIREPLACE`& CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O REMARKS: pinr DATE INSPECTOR pF SOUIyo{o TOWN OF SOUTHOLD BUILDING DEPT. 631-765-1802 qa50 INSPECTION [." ] . FOUNDATION "1ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] I A/T��ION/C\AUnnLKIN,yG� [ ] FRAMING /STRAPPING [ FINAL f�e 'J e -o ►'`Ins r P [ ] FIREPLACE & CHIMNEY [ ]- :FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] -FIBElqfSISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [. ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL RE A S: on OKI/ DATE d,dwlo::,/00" INSPECTOR FIELD INSPECTION REPORT DA.TE COMMENT FOUNDATION(IST) ------------------------------------ C FOUNDATION(2ND) � z 0 c.: 0 ROUGH FRAMING& SF m PLUMBING y r 1 r INSULATION PER N.Y. STATE ENERGY CODE vJ .Gl, w FINAL h ADDITIONAL COMMENTS " e- m l 5 p Z m C X i b No `J1 z x 4 y x d M b H oaf TOWN OF SOUTHOLD—BUILDING DEPARTMENT y; Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 �y • a Telephone(631) 765-1802 Fax (631)765-9502 hgps://www.southoldtgMMp3L.gov Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only PERMIT NO. Building Inspector: l l ' jU% 26 20 Applications and forms must be filled out in their entirety.Incomplete applications will not be accepted. Where the Applicant is not the owner,an DING DF L - Owner's Authorization form(Page 21'shall be completed. Date:5.15.2023 OWNER(S)OF PROPERTY: Name:Nako Rizo SCTM#1000-106-3-2 Project Address: 400 East Road, Mattituck Phone#: 917-599-8037 Email:rizosaranda@yahoo.com Mailing Address: 19-19 21 st Rd. Long Island City NY 11105 CONTACT PERSON: Name:Joan Chambers Mailing Address:PO Box 49 Southold NY 11971 Phone#: 631-294-4241 TEmail:joanchambersl 0@gmail.com DESIGN PROFESSIONAL INFORMATION: Name:LOU Schwartz Tiderunner Engineering Mailing Address:? Ridgewood St, Bay Shore, NY 11706 Phone#:(631) 410-6838 Email:tiderunnereng@gmail.com CONTRACTOR INFORMATION: Name: Mailing Address: Phone#: Email: DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ®Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: ❑Other Deck $ Will the lot be re-graded? ❑Yes BNo Will excess fill be removed from premises? ❑Yes BNo 1 PROPERTY INFORMATION Existing use of property: Residence Intended use of property:same Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to R_40 this property? ❑Yes BNo IF YES, PROVIDE A COPY. ❑ Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,ordinances or Regulations,for the construction of buildings, additions,alterations orfor removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class'A misdemeanor pursuant to Section 210AS of the New York.State Penal Law. Application Submitted By(print name): BAuthorized Agent ❑Owner Signature of Applicant: Date: STATE OF NEW YORK) SS: COUNTY OF ) Joan Chambers being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Agent (Contractor,Agent, Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this day of 120 Notary Public PROPERTY OWNER AUTHORIZATION (Where the applicant is not the owner) I� Nako Rizo residing at 400 East Road, Mattituck NY 11952 do hereby authorize Joan Chambers to apply on my behalf to a Tow of Southold Building Department for approval as described herein. Owner's Signature Date Nako Rizo Print Owner's Name 2 15 U U ING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD o JUN 16 2Wn Annex- 54375 Main Road - PO Box 1179 C-0 U Southold, New York 11971-0959 �y off ` Buiidin De phone (631) 765-1802 - FAX (631) 765-9502 Te Town orf S paw(@-southoldtownny.gov — seand c southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFOR . TION (Ail Information Required) Date: Company Name: Electrician's Name: License No.: Elec. email: Elec. Phone No: ❑I request an email copy of Certificate of Compliance Elec. Address.: JOB SITE INFORMATION (All Information Required) Name: /Qa le� Address: q60 Cross Street: Phone No.: Bldg.Permit email: Tax Map District: 1000 Section: Block: �J Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): L—OD M \ ok, I Square Footage: Circle All That Apply: Is job ready for inspection?: YES ❑ NO Rough In Final Do you need a Temp Certificate?: YES NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect Flood Reconnect Elservice ReconnectOUnderground DOverhead # Underground Laterals 1 F12 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION � I 63 ING DEPARTMENT- Electrical Inspector O� TOWN OF SOUTHOLD o JUN 1 6 awn Annex- 54375 Main Road - PO Box 1179 W Southold, New York 11971-0959 4,,E O��` Building ®epa�mTe�ephone (631) 765-1802 - FAX (631) 765-9502 Town®f sog b�(@southoldtownny.gov seandCo7southoldtownny.aov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 16 - � Company Name: Electrician's Name: License No.: Elec. email: Elec. Phone No: ❑I request an email copy of Certificate of Compliance Elec. Address.: JOB SITE INFORMATION (All Information Required) Name: a Q � Address: D +— Cross Street: Phone No.: Bldg.Permit#: �j email: Tax Map District: 1000 Section: Block: 3 Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Square Footage: Circle All That Apply: Is job ready for inspection?: ❑ YES ❑ NO ❑Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES ❑ NO Issued On Temp Information: , (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect[]Service Reconnect❑Underground❑Overhead # Underground Laterals 1 2 H Frame M Pole Work done on Service? Y N Additional Information:- PAYMENT DUE WITH APPLICATION PERMIT# Address:. Switches Outlets GFI's Surface Sconces H H's UC Lts Fridge HW POOL Fans Mini Fr. W/D PanelPump Exhaust Oven Sump Heater Trnsfmr Smokes DW Generator Salt Gen. Carbon Micro GrbDis Water Bond Lights Heat Pucks ERV HOT TUB/SPA Inst Hot DeHum Transfer Disc Co bo Cooktop t inisplit Blower C AH Hood ower Service Amps Have Used Sub Amps Have Used Comments ��� 3 . 1 (t�f) 6p-�1 , 83 4000„ E 120.0, N - -�- S ( ate I 1 Alw I IEXIST.PATIO 1 1� II 2'- PROPpS ECI( •� I Vast 1 OOST.BAI.00NYABOVE I I ' 1 EX,ST.2 STORYNOUSE �el r ib I ' � I ,n I ��1 O �j N 1 I co J to Z I o I I 1 I I ' 1 N I I I 1 f 1 � I \ i 1 N. 86 00' 300 W 74.49' -— - - — - EAST ROAD RIZO RESIDENCE DECK LOCATION 400 EAST ROAD MATTITUCK NY 1000-106-3-2 1"= 20.0' 6.26.23 Certifications indicated hereon signify that this plat of the property depicted hereon was made in accordance with the existing Code of Practice for Land Surveyors adopted by the New York State Association of Professional Land Surveyors_ This certification is only for the lands depicted hereon and is not certification of hile, zoning or freedom of encumbrances. Said certifications shall run only to the persons and/or,entities listed hereon and are not transferable to additional persons, entities or subsequent owners. "Eli C E IJa N - 7 2015 BLDG DEPT TAX LOT 27 TG NN OF SOUT40LD BLOCK LOT I SECTION 99 102 I 1 / ' o s.0® CLF 0.3'w MONUMENT 4002' E 0 NSJ0 CE 5NS �0. LF LINK .•�« MONUMENT 0,7V �r ON CHAIN CONCRETE WA IL ON FOUND ON UNE ME AL Pos'is 0.2'W Si O 8' O f WALL ' VINYL 0.7 S FENCE I FENCE r 0.4'W WOOD rr O CONCRETE 1 ON LINE DRAIN P.ATlO T w Z INLET 0 0 = 1ind STY PaCONY u.� N� 24.8 3 N 'I Z � 31.2' ►� ` n 7 0' W m NC) 2 STORY w "` oN / N NO m c °� m 400 N U W 36.2' 1 GARAGE48.4' 2nd STY R I SALCONY o O °0 AS-.. =�= FENCE E8 o o LOT STOOP --_` _ Q'-----LOT' --- - -- - s .103 �- " 'CLF � a ooa ,� ON 104 3 CUR6 W LINE _ • Z �16 In WALL � � 2 ON NE j (xi O ? i� WATER M � I Cl METER 0 WAL[! ® 0) ON 1 MAS. WALL WALL LINE ON PILLAR ON LINE LINE O GATE CHAIN CRETE WAL ~ ' �- r ALL EOGE N 86-oo'30u w PAVEMENT 74.490 EAST READ LOT AREA=14,487 SQUARE FEET. The offsets or dimensions shaven from structures to the property lines are for a specific purpose and use,and therefore,are not intended to guide in the erection of fences,retaining walls, pools,patios, planting areas,additions to buildings and any other construction Subsurface and environmental concloons were not examined or considered as a part of this survey. Easements, Righis-oMay of record,:f any,are not shown. Property comer monuments were not placed as a purl of this survey. - - © 2014 BBV PC Barrett Tax Map: DISTRICT 1000 SECTION 106 BLOCK 3 LOT 2 Bonacci & Unoulhorized alteration or addition 10 ; r Map of: CAPTAIN KIDD ESTATES this survey is a violation of Section Van Weele, PC 7209 of New York State Education law Civil Engineers 175A Commerce DriveP i 03 Map Block: 7 Surveyors Hauppauge, NY 11788 T 631 435.1111 Filed: 7/19/1949 No.: 1672 County: SUFFOLK Planners F 631 435 1022 www.bbvpc.com Situate: MATTITUCK,TOWN OF SOUTHOLD Ceir i'ed to: Tide NO.: Revision By Date Copies of this survey map not bear- NAKO RIZO ing the land surveyor's embossed SOSE RIZO seal and signature shall not be con- sidered to be a true and valid copy Surveyed . B.F. Drafted J.F. Checked Scale: 1"_ Date: DECEMBER 23 2014 Project No.: A080395A RIZO RESIDENCE aQ, 400 - EAST ROAD MATTITUCK N .Y. 18'-0"— EXISTING: SINGLE FAMILY RESIDENCE CTM# 1000-106-03-02 NEW GUARDRAIL TO 'ODE 2-2X10 BLOCKING BETWEEN DECK JOISTS @ GUARD RAIL POST ATTACHMENTS-- ARRAVED AS NOTE ZONE R-40 .36 ACRES DATE PROPOSED: FEE: BY: ADD NEW 18'-0"x12'-0" (216 SQ.FT.) SECOND FLOOR ... .. ........ - NOTIFY BUILDING DEDARTMENT AT. DECK AT REAR OF HOUSE. NEW 5/4 X 6 COMPOSITE DECKING 765-1802 SAM TO 4 PM FOR THE FOLLOWING INSPECTIONS: EXIST.FLAT ROOF OVER 1. FOUNDATION - TWO REQUIRED �_MUDROOM BELOW FOR POURED CONCRETE _4-1 2. ROUGH - FRAMING & PLUMBING EXIST.GUARD RAIL EXIST.GUARD RAIL 3. INSULATION GENERAL NOTES 4. FINAL - CONSTr;;7TI 7N MUST 1. All work shall conform to the requirements of the Residental Code of New York BE COMPLET= �C, C, 0. EXIST.BALCONY State, County and Town Department Regulations, Utility Company requirements and EXIST.BALCONY ALL CONSTRUCTI,�,. -r-!ALL MEET THE best trade practises. REPLACE DECKING REPLACE DECKING ••iEQUIREMENTS OF THE CODES OF NEW 2. Before commencing work the Contractor shall file all documehts required by the CORK STATE. NOT RESPONSIBLE FOR Building Department, pay all fees required by local agencies and obtain all required EXIST,WINDOW EXIST.SLID.GL.DOOR EXIST.SLID.GIL.DOOR ')ESIGN OR CONSTRUCTION ERRORS. permits. 3. The Contractor shall visit the site and verify all dimensions and the existing conditions affecting the work prior to construction. Any discrepancies which would COMPLY WITH ALL CODES OF interfere with the satisfactory completetion of the work described herein shall be NEW YORK STATE & TOWN CODE-- reported to the architect or property owner. Do not start work until such conditions AS REQUIRED AND CONDITIONS 01: have been examined and a course of action mutually agreed upon. Failure to notify KITCHEN the owner or architect of unsatisfactory conditions will be construed as an acceptance LIVING ROOM of the conditions to properly perform the required work. SGVI H 9fi0'�_ 1N PtANNING BOAR) 4. All work is to conform to the drawings and specifications of the architect and engineer consultants. SOUTROLD70 WIRUSTEES 5. The Contractor is to maintain a complete and up to date set of plans on the job site at all times 6. The drawings are not to be scaled under any circumstances. 7. It shall be the Contractor's responsibility to ascertain all prevailing procedures including storage and toilet facilities,protection of existing work to remain,access to OCCUPANCY OR work area, hours of permitted work,availability of water and electric power and all other conditions and restrictions for this particular location in order to execute the EXIST. 2 N D FLOOR USE IS UNLAWFUL work in a careful and orderly manner with the least possible disturbance to the public. PROPOSED 2 N D FLOOR DECK 8. The Contractor shall make the neccesary arrangements to utilities and services WITHOUT CERTIFICAT temporarily disconnected while performing the work as required. 1/4 it 1-011 9. The Cotrator shall povide all dimnsions nd cut-ots for othr trades. 1 OF OCCUPANCY 10.The Contnracctor shall pr rovide propere shoringa and bacing for all remaining structure prior to removal of existing structure. 11. Plumbing, electrical, HVAC and similar work shall be performed by licensed 14"DIA.POUR.CONC.PIER ',,STAIN STORM WATER RUNOFF persons who shall arrange for and obtain all required inspections. The General @ 36"MIN.BELOW FIN.GRADE o — — — — — — — — — — — -- — — — — — — — — — — - - )URSUANT TO CHAPTER 236 Contractor shall be responsible for scheduling all other inspections as required. 12.The Contractor is solely responsible for construction safety and shall hold the 6X6 ACQ POST T I'HE TOWN CODE. ANCHORED TO P ERS W/ owner and architect harmless from litigation arising out of the Contractors failure to 3-2X12 ACQ GIRDER SIMPSON PPBZ PORCH POST BASE provide construction safety means and methods. ATTACHED TO POST W1 I W/1"STANDOFF&EPDXY COATING SIMPSON LPC POST CAP OR EQUIVALENT F— — — — — — — — — —EXIST.ROOF ABOVE — — — — — -- I CONSTRUCTION NOTES U) W W C/)�_z LJ) w < 1. All footings shall rest on undisturbed soil at a minimum of 36"below fin.grade. F5 o 52. Poured concrete shall have a minimum psi of 2800 at 28 days unless noted. 0of X y 3. Sill plates shall be preserved, treated wood and be installed above a 16 oz. FD 0� 0 W 0 U) copper termite sheild. C)'.U.) 4. Shingle siding shall conform to ASTM D 3679 and be installed in accordance ,WZ @0 0 0 Of W(D with the New York State Building Code and manufacturers specifications. U) L— _J- - -- — — — — — — — — — — — — 5. Pilings shall be installed by a licensed contractor to a depth and bearing agreed CZ)-� F_ X Z<U) <, EXIST.BALCONY ABOVE upon by an engineer and certificates shall be issued stating same. EXIST.BALCONY'ABOVE 0 2-2X12 LEDGER 6. Unless otherwise noted all framing and structural wood components shall be CL 0 FASTENED To HOUSE FRAMING&SOLID BLOCKING W/ #2 or better Douglas Fir. SIMPSON 1/2"x6"SDWS EPDXY COATED 7. All framing techniques and methods shall be as prescriptive design based on TIMBER SCREWS @ 12"OC STAGGERED— — — — — — — — — — — — — — — — — — — — — — — — AF&P Wood Frame Construction Manual for One and two Family Dwellings(WFCM) or as specified in R301.2.1.1 EXIST.2X4 -- ADD SOLID BLOCKING 16"OC ❑ 8. All building envelope components shall comply with Chapter 6 of the Energy @ LEDGER ATTACHMENT Conservation Code of the State of New York. @ 9. Fireblocking shall be provided in all wood framed construction in accordance with NYS Code R 602.8 to form an effective fire barrier between stories and between the top story and roof space. 10. Protective panels shall be provided for glazed openings in accordance with NYS code R301.2.1.2 if they are required. T 11. All portions of the new structure are designed to comply with local geographic and climatic criteria as stated in the following table. GEOGRAPHIC & CLIMATE DESIGN CRITERIA GROUND SNOW LOAD 45 psl L WIND SPEED 130 MPH SEISMIC DESIGN CATATGORY B WEATHERING SEVERE EXIST. FIRST FLOOR FROST LINE DEPTH 36" TO PROPOSED 2ND FLOOR DECK DECAY TERMITE THREAT SLIGHTMODERATE TO MODERATE HEAVY WINTER DESIGN TEMPERATURE 11 1-011 FLOOD HAZARD AS NOTED 1/4if 1 DECK GUARD RAIL TO MEET CODE 36"MIN.HIGH GUARD RAIL TO CODE 4"MIN SPACE BETWEEN BALUSTERS 2 2X10 BLOCKING BETWEEN EXISTING CANTILEVERED 2X8 �;CK JOISTS @ GUARD RAIL BALCONY JOISTS TO REMAIN POST ATTACHMENTS _2X10 @ 16"OC DECK JOISTS ADD SOLID BLOCKING ANCHOR 2X1 0 DECK JOISTS TO ANCHORED TO GIRDER W/ TOP OF LEDGER W/HS HURRICANE TIES SIMPSON HS HURRICANE TIE @ LEDGER ATTACHMENT 2-2X12 LEDGER 3-2X12 ACQ GIRDER EXIST.2X4 @ 16"OC FASTENED TO HOUSE FRAMING ATTACHED TO POST W/ &SOLID BLOCKING W/ SIMPSON LPC POST CAP SIMPSON 1/2"x6'SDWS EPDXY COATED OR EQUIVALENT TIMBER SCREWS @ 12"OC STAGGERED 4X4 CROSS CING ATTACHED POST& X4 CROSS CING AC HED T POST&\GIRDER W/ PSON KBS1Z CXFASTENERS R EQUAL C C wr ACQ POST ANCHORED TO PIERS W/ Q: SIMPSON PPBZ PORCH POST BASE W/1"STANDOFF&EPDXY COATING DECK PLAN, SECTION & ELEVATION 77006 SCALE AS NOTED MAY 2023 PAVER PATIO S iV SION EXIST.FOUNDATION 14"DIA.POUR.CONC.PIER T_ L L I L I L I A 101 SECTION #1 ELEVATION 1 OF 1 if 111 it f11 1/4 = 1 -0 1/4 1 _0 PO BOX 49 JOAN CHAMBERS SOUTHOLD NY 11971 631-294-4241