Loading...
HomeMy WebLinkAbout52174-Z TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 52174 Date: 08/12/2025 Permission is hereby granted to: David N Posnett 11 E 87th St Apt 9G New York, NY 10128 To: install roof-mounted solar panels on an existing single-family dwelling and an accessory structure as applied for. Two CO's will be required simultaneously. Premises Located at: 505 Skunk Ln, Cutchogue, NY 11935 SCTM# 97.4-3.1 Pursuant to application dated 07/14/2025 and approved by the Building Inspector. To expire on 08/12/2027. Contractors: Required Inspections: Fees: SOLAR PANELS $200.00 CO-RESIDENTIAL $200.00 Total S400.00 -Building Inspector 4 ',m�r � �°° TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone (631) 765-1802 Fax (631) 765-9502 : � ww. outholdtor ��n oy Date Received APPLICATION FOR BUILDING PERMIT or Office Use Only PERM[T NO. I Building lnspector.—.-_ —w Applications and forms must be filled out in their entirety.Incomplete 110o caf , applications will not be accepted. Where the Applicant Is not the owner,an Owners Authorization form(Page 2)shall be completed. Date: 6/30/2025 OWNER(S)OF PROPERTY: Name:David Posnett sCTM# 1000- 097.00 - 04.00 - 003.001 Project Address: 505 Skunk Lane, Cutchogue, NY 11935 Phone#: (631) 379-2200 Email: dposnett@med.cornell.edu Mailing Address: 505 Skunk Lane, Cutchogue, NY 11935 CONTACT PERSON: Name: Michael Calise Mailing Address: 2941 Sunrise Hwy, Islip Terrace, NY 11752 Phone#: ( 631) 647-3402 Email: hppermitting@harvestpower..net DESIGN PROFESSIONAL INFORMATION: Name: Michael Dunn, R.A. Mailing Address: 256 Orinoco Dr, Brihtwaters, NY 11718 Phone#: (631) 665-9619 Email; Glenn@grahamassociates .com CONTRACTOR INFORMATION: Name: Harvest Power LLC Mailing Address: 2941 Sunrise Hwy, Islip Terrace, NY 11752 Phone#: (631) 647-3402 JEmail: hppermitting@harvestpower.net DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑AdditionAlteration ❑Repair ❑Demolition Estimated host of Project: ❑Other —3VZ6. 00 Will the lot be re-graded? ❑Yes ®No Will excess fill be removed from premises? ❑Yes ❑No 1 PROPERTY INFORMATION Existing use of property: Residence intended use of property: (no change) Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes ®No IF YES, PROVIDE A COPY. ®Check Box After Reading: The owner/contractor/design professional Is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the Issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By( ( ame): MIG I Calise PIlAuthorized Agent ❑Owner Signature of Applicant: Date: 6/30/2025 STATE OF NEW YORK) SS: COUNTY OF Suffolk ) Michael Calise being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Agent (Contractor,Agent, Corporate Officer,etc.) �...�. of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this _day of ` ..... _. 2095 � A f rPT C.HAPSHE o ry ulalic,State of New York No.OIHA4928056 Qualified in Suffolk County Term expires L12162 PROPERTY OWNER AUTHORIZATION _..,,....,., , ............... .. ..... .... . ..... ..... ......_.. .(�,her•e"f"fie a°pK�iican�is i�o�tfi"e"owner � ........ .. ..... ... .. ..... _ .. . David Posnett residing at 505 Skunk Lane, Cutchogue, NY, 11935 do hereby authorize Michael Calise - Harvest Power LLC to apply on my behalf to the Town of Southold Building Department for approval as described herein. l �A % 6/30/2025 Owner's Signature Date David Posnett Print Owner's Name 2 k � Ita�ilclin- lct gar°trnetat, ticattu"sorr (Where the Applicant is neat the Owner) I, (Print property e (David Posnett ._...� er' a .._._..,... pe y owns nme r , (Mailing Addre g ) restdin at 5 Skunk La ut.c.„...,.hague, NY, 11935 do hereby authorize Michael Calise �._.. �..u. (Agent) Harvest Power LLC to apply on my behalf to the Southold Building Department. d 6/30/2025 ') rat � ttatatt° (Date) David Posnett (print Owne ,s Name) ..._ ti 1 CONSENT TO INSPECTION David Posnett mmIT M ,,the undersigned, do(es)hereby state: ............. ._._ _._..._...ww...w_..............._-'Owner(s)Name(s) That the undersigned (is) (are)the owner(s)of the premises in the Town of Southold, located at 505 Skunk Lane, Cutchq9ue, NY 11935 which is shown and designated on the Suffolk County Tax Map as District 1000, Section 097.00 , Block 04.00 , Lot 003.001 That the undersigned(has)(have) filed, or cause to be filed,an application in the Southold Town Building Inspector's Office for the following: SOLAR That the undersigned do(es) hereby give consent to the Building Inspectors of the Town of Southold to enter upon the above described property, including any and all buildings located thereon, to conduct such inspections as they may deem necessary with respect to the aforesaid application, including inspections to determine that said premises comply with all of the laws, ordinances, rules and regulations of the Town of Southold. The undersigned, in consenting to such inspections;do(es) so with the knowledge and understanding that any information obtained in the conduct of such inspections may be used in subsequent prosecutions for violations of the laws, ordinances, rules or regulations of the Town of Southold. ............ .25 Dated: _............._ .w.wti_,.,.,.,.,.,.,.,.,.,.,.,.,.,.,. .................... (Signature) David Posnett (Print Name) ....___w.._(Signature) _. .............. .�.�......._.........__.__.(Print Name)..._�. ..w...� BUILDING DEPARTMENT-Electrical Inspector TOWN OF SOUTHOLD Town Hall Annex - 54375 Main Road - PO Box 1179 Not Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 y° 'amesh southoldtownn . ov — seand@southoldtownnv.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Company Name: Harvest Power LLC Electrician's Name: Carlo Lanza License No.: ME-68518 Elec. email: hppermitting@harvestpower.net Elec. Phone No: (631) 647-3402 211 request an email copy of Certificate of Compliance Elec. Address.: 2941 Sunrise Highway, Islip Terrace, NY 11752 JOB SITE INFORMATION (All Information Required) Name: David Posnett Address: 505 Skunk Lane, Cutcho ue, NY 11935 Cross Street: Phone No.: (631) 379-2200 Bldg.Permit#: email:dposnett@med.cornell.edu Tax Map District: 1000 Section:097.00 Block: 04.00 Lot: 003.001 BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Installation of a 8.28 kW Solar PV system with (18) REC Alpha Pure 460w BBB Roof mounted panels. Square Footage: Circle All That Apply: Is job ready for inspection?: YES NO Rough In F Final Do you need a Temp Certificate?: F] YES NO Issued On Temp Information: (All information required) Service SizeF]1 Ph FJ3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 02 H Frame Pole Work done on Service? Y nN Additional Information: PAYMENT DUE WITH APPLICATION Graham Consulting Cor . . 256 Orinoco Drive, Trite A Brightwaters,NY 11718 Planning&Design (631)665-9619 July 8, 2025 Town of Southold Building Department 54375 Rt. 25 Southold, NY 11971 Re: David Posnett MD Residence 505 Skunk Lane Cutchogue, NY Proposed 8.82 kWDC, 6.84 kWAC PV System To Whom It May Concern, Please be advised that I have analyzed the existing roof structure at the above-mentioned premises and have determined that it is adequate to support the additional load of the solar panels and a 140 mph wind load and 20 psf snow load without overstress, in accordance with the following: The 2020 New York State Uniform Fire Prevention and Residential Building Code; Town of Southold Local Code, Long Island Unified Solar Permit Initiative, (LIUSPI); and 2020 National Electric Code NFPA 70/2020 National Electric Code including ASCE7-16 If you have any further questions, do not hesitate to call. , 51,w.. 4„Fay Wp+""ry. xR °at �K ITt , RA Suffolk County Dept.of Labor,Licensing&Consumer Affairs \3 HOME IMPROVEMENT LICENSE Name CARLO LANZA Business Name Harvest Power LLC This certifies that the bearer is duly licensed License Number H48165 by the County of suffolk Issued: 11/18/2010 W"vt,i T. Rosa y Expires: 11101/2026 Commissioner Suffolk County Dept,of Labor,Licensing$Consumer Affairs MASTER ELECTRICAL LICENSE Name CARLO P LANZA Business Name TNs ce'rtddi' ghat�, a Harvest Power LLC 6esrer is duly Ucernsed License Number ME4)8518 5y Chm County cP suffm Issued: 111301202 Cabr' a. Expires: 11/01/2025 Commissioner VED IS NOTEID ap.# ,5 FEE BY: NOTIFY BUILDING DEPARTM;ENTAT I31-7 " 'I d AM TO 4PIVI FOR THE FOLLOWING INSPECTIONS. I. FOUNDATION-TWO REQUIRED FOR POURED CONCRETE 2. ROUGH_FRAMING&PLUMBING & INSULATION 4. FINAL-CONSTRUCTION MUST RE COMPLETE FOR C.O. I ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTON ERRORS C l l-M ALL OD F NEWAS REQUIRED AN5 COND1.7-IONS, OF " K STATE 7"' N CODES, SOLO TOWN 7 SOUTH W P �� 13f) Ej L,D ( ¢'( TE S S ( HOLD HP OCCUPANCY OR USE IS UNLAWFUL WITHOUT CERTIr-jr OF OCCUpANCy IELE- 1"RICAL INSPEanON REQUIRED PHOTOVOLTAIC ROOF MOUNT SYSTEM 18 MODULES-ROOF MOUNTED - 8.28 kWDC, 6.84 kWAC � 505 SKUNK LN, CUTCHOGUE, NY 11935, USA HARVEST HARVEST POWER LLC 290 SUNRISE HIGHWAY ISLIP SYSTEM SUMMARY: GOVERNING CODES: SHEET INDEX ?ERRACE,98 3585 (N)18-REC SOLAR REC460AA PURE-RX(460W)MODULES PV-0 COVER SHEET 1Ec(soi)sea sae 2017 NATIONAL ELECTRICAL CODE ��� 1752 cR�D (N)18-ENPHASE ENERGY IQ8X-80-M-US MICRO-INVERTERS 2017 NEW YORK STATE UNIFORM CODE PV-1 SITE PLAN WITH ROOF PLAN ripEL i {N}02-JUNCTION BOXES 2020 NEW YORK STATE RESIDENTIAL CODE PV-2 ATTACHMENT DETAILS (E)200A MAIN SERVICE PANEL WITH(E)200A MAIN BREAKER PV-3 THREE LINE DIAGRAM (E)200A MAIN SERVICE DISCONNECT WITH(E)200A MAIN BREAKER PV-4 PLACARDS&WARNING LAB Lki IN)60A FUSED AC DISCONNECT PV-5 ADDITIONAL NOTES ="'r• _ Z (N)ENPHASE IQ COMBINER BOX PV-6+ SPEC SHEETS ) _ -~ (N)125A SOLAR LOAD CENTER 9817 DESIGN CRITERIA: Of NEW VERSION ROOF TYPE:-STANDING SEAM METAL G-EveR:R',N -I DATE_ I REv. ROOF CONDITION:OK BLDG.PERMR 9](OY2a25 � 9 ROOF FRAME:-2"X10"RAFTERS @16"O.C.(MAIN HOUSE) ROOF FRAME:-3.5"X8"RAFTERS @24"O.C.(GARAGE) STANDING SEAMS:-@12"O.C.SEAMS SPACING STORY:-ONE STORY SNOW LOAD--25 PSF WIND SPEED:-130 MPH = WINO EXPOSURE:-C _.. GENERAL NOTES- r /� 1. INSTALLATION IN ACCORDANCE WITH MANUFACTURER ARRAY LOCATIONS RECOMMENDATIONS. PROJECT ROJECT SITE 2. ENGINEER TO INSPECT PROJECT AFTER INSTALLATION _ AND CERTIFY COMPLIANCE. �� .: FibLI ass 3. PROJECT TO BE INSTALLED WITH CODE COMPLIANT j i > PROJECT NAME RACKING INSTRUCTIONS FOR UNI-RAC SOLAR MOUNT 1 25 W SYSTEM. U 4. FOLLOW BALLASTING SCHEDULE ON ROOF PLAN. LU 5. HARVEST POWER,LLC.,THE SOLAR INSTALLATION EAST C U T C H O G U E �L' �` � p 0 CONTRACTOR,COMPLIES WITH ALL LICENSING&ALL I RELATED REQUIREMENTS OF THE GOVERNING o O MUNICIPALITIES AND THE LOCAL ELECTRIC UTILITY i W � 1L' Zrn_ C) < 6. THIS PROJECT WILL COMPLY WITH THE CURRENT NEC k ad] S Z,.. (D d W REQUIREMENTS INCLUDING ARTICLE 690 SOLAR Z O r LL. PHOTOVOLTAIC PV SYSTEMS. I— r' r U 7. THE ROOF WILL HAVE NO MORE THAN A SINGLE LAYER r W U)� O J Z OF ROOF COVERING IN ADDITION TO THE SOLAR t Z o C9 p EQUIPMENT. U) So 0 O'o Z) O 8. INSTALLATION WILL BE FLUSH-MOUNTED,PARALLEL 505 Skunk Ln, � .. TO AND NO MORE THAN 6.5"ABOVE ROOF r � 9. MAINTAIN A MINIMUM OF 18"CLEARANCE AT RIDGE � $y NY 0 j d = AND AT ONE GABLE EAVE. 11935,United States >Q U 10. THIS DESIGN COMPLIES WITH 130 MPH WIND REQUIREMENTS OF THE RESIDENTIAL CODE OF N.Y.S AND ASCE 7-16. SHEET NAME 11. WHEREVER THE ROOF PLAN DOES NOT COMPLY WITH ACCESS AND VENTILATION REQUIREMENTS OF THE COVER SHEET UNIFORM CODE,HARVEST POWER PROPOSES THAT ALTERNATIVE VENTILATION METHODS WILL BE ' SHEET Slze EMPLOYED.REVIEW AND APPROVAL SHALL BE AT THE DISCRETION OF THE MUNICIPALITY IN WHICH THIS _. ANSI 8 DOCUMENT HAS BEEN FILED. 11"X 17" 12. THE DESIGN PLANS COMPLY WITH THE 2020 NEW YO RESIDENTIAL UNIFORM FIRE _ 1 AERIAL PHOTO 2 VICINITY MAP RESIDENTIAL BUILDING CODE. SHEET NUMBER PV-0 SCALE NTS PV-0 SCALE:NTS w PV-0 MODULE TYPE,DIMENSIONS&WEIGHT_ NOTE:THERE ARE NO FENCE ROOF ACCESS AREA: 'NUMBER OF MODULES=18 MODULES AND GATE IN THIS PROPERTY SHALL BE LOCATED IN AREAS THAT DO NOT REQUIRE THE PLACEMENT OF GROUND OVER OPENINGS SUCH AS WINDOWS OR DOORS,AND LOCATED AT STRONG POINTS OF MODULE TYPE=RED SOLAR REC460AA PURE-RX(460W)MODULES BUILDING CONSTRUCTION IN LOCATIONS WHERE THE ACCESS POINT DOES NOT MODULE WEIGHT=50.0 LBS 122.7 KG. CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS,WIRES OR SIGNS. H, MODULE DIMENSIONS=68.0"X 47.4"=22.38 SF UNIT WEIGHT OF ARRAY=223 ESE HARVEST , p HARVEST POWER LLC Lt y SUNRISE HIGHWAY ISLIP e? S'' RRAGE.NY 11752 t ,~A Y -:{801)985-%55 :.e -at net �Q t Z{f>1 / tq 817 (E)DETACHED O� STRUCTURE VERSION fGJ j14 /' / it j DESCRIPTION DATE REV- BLDG.PERMR 0TM3t2025 0 \ CP \ F� / \ PROJECT NAME C3 11 � ' U do /` / L11S� Z W O LU wCD zrn ooQ � d (E)TREE(TYP.) Z Z o -1 O EXISTING -z - ��- v Y H O LLI �G DRIVEWAY -/`�/ ���go Z L CO ID CD H c 0 cp- TRENCH DETAIL j C SHEET NAME —SEE ENLARGED SITE PLAN WITH z VIEW ON PV-1.1 g =° ROOF PLAN t " � SHEET slzE yf- 6"MIN SAND ANSI B ----------- 1"SCH 40 PVC CONDUIT 11°X 17" I NOTE:TRENCH CONDUIT TO `f` -1�`�"i :HAVE 24"M W IM UM BURIAL ,SITE PLAN WITH ROOF PLAN DEPTH UNDER DRIVEWAY Wit= SHEET �N{UMSER SCALE:1164"'=T-O" i P v-1 ti MODULE TYPE, DIMENSIONS&WEIGHT ROOF ACCESS AREA. SHALL BE LOCATED IN AREAS THAT DO NOT REQUIRE THE PLACEMENT OF GROUND NUMBER OF MODULES=1S MODULES OVER OPENINGS SUCH AS WINDOWS OR DOORS,AND LOCATED AT STRONG POINTS OF _ MODULE,TYPE=REC SOLAR REC460AA PURE-RX(460W)MODULES BUILDING CONSTRUCTION IN LOCATIONS WHERE THE ACCESS POINT DOES NOT MODULE WEIGHT=50.0 LBS(22.7 KG. CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS,WIRES OR SIGNS. MODULE DIMENSIONS=68.0"X 47.4"=22.38 SF H�" UNIT WEIGHT OF ARRAY=2.23 PSF HARVEST l HARVEST POWER LlC 2941 SUNRISE HIGHWAY ISLIP TERRA E NY 1 752 (E)200A MAIN SERVICE DISCONNECT Ti y Zm G A TE:rao1>ss9 ssas WITH(E)200A MAIN BREAKER ' Z (N)1"PVC CONDUIT _- ' (OUTSIDE) SO T, RUN 7/8"ABOVE ROOF ' G (E)UTILITY METER ' / m0� (N)JUNCTION BOX(TYP.) - Z#0� (N)60A FUSED AC DISCONNECT } (N)ENPHASE IQ COMBINER BOX y_- t SEW Yfl VERSION DESCRIPTION DATE REV- t\ H DG.PERMIT 07,03:2025 0 (E)200A MAIN SERVICE PANEL WITH(E)200A MAIN BREAKER (INSIDE) 1 � ROOF#1—'7 1 (06)REC460AA PURE-RX(460V� I � d-"w 6 RAFTERS=2"X10"@16"O.0 STANDING SEAMS=@12"O.0 C 161"AZIMUTH,37`TILT f PROJECT NAME Z W (06)ENPHASE ENERGY IQ8X-80-M-US= U MICRO-INVERTERS Z Q 0 c o U) ui o O= x z rn o Q 0 z o a I- �z p " � Y LLI rn F' O (E)GARAGE W o :3 Z TRENCH DETAIL R t p �_ no t 1'SCH 40 PVC CONDUIT a. TRENCH-85'-0" d = z_ i ( r `:t t Q J Q Q (N)125A SOLAR LOAD CENTER CD y l t t t m ,.— 6"MIN SAND t t SHEET NA - 1"SCH 40 PVC CONDUIT ROOF#2 - ; t t SITE PLAN WITH (12)REC460AA PURE-RX(460W) ROOF PLAN —U �.., \1 -NOTE. TRENCH CONDUIT TO _ RAFTERS=3.5"X8"@24"O.G z SHEET SIZE _ iF \ :HAVE 24"MINIMUM BURIAL STANDING SEAMS=@12"O.0 ANSI g ;DEPTH UNDER DRIVEWAY 161`AZIMUTH,37'TILT 11"X 17" t,SITE PLAN WITH ROOF PLAN (12}ENPHASE ENERGY ICRO-NVERTERS- � SHEET NUMBER SCALE:1r'16"=1'-0" PV-1.1 i . S-5-U Top HARVEST POWER LLC 2 41 SUNRISE HIGHWAY ISLIP 'Er r TERRACE,NY 11752 TEL:(801)9893585 .V�_%�� �".4�'g !�_ tr.;8rves:•e^.,.rarne: M8-1.25 Threaded Hole 0.90[22.91 i" \\ co it <' ,. rft 0.4o[iozj ` 17, 0.50 12.71 t-'r C 0.54[i 3.7] VERSION DESCRIPTION DATE I REV. 75[19.1] sLDG.PER- o7roa2- 1.50 8.1] o i Lem ff Front Right [3 M8-1.25 Threaded Hole tcrR1TT } 1.50[38.1] �tt�� + 1.13[28.61 } { PROJECT NAME + } 0.31[7.9] LU t U (4x)3/8-24 Threaded Hole 0.55[14.0 I ( LU (- -�0.38[9.5] [-1.25[31.81 0 ::� oo 0 1.50[38.1] W I, o 0Zwvn¢: 0 2. 4 � z >- o -jcA F DZ oru- curERuu.: METAL ROOF INNOVATIONS,LTD. ~ Y LU ~ 0 ODQ Series AL I 8750 WALKER RD Z -U -p F > � COLORADO SPRINGS,CO 80908 -O o D O 0.390lbs 719495-0518 O 2 0 t General Notes. 1. HARDWARE 719-495-OM(FAX) 0- 0 Z 1. S-5-1-11 S-5-U[CCDj C) Q a 2. 0.9"3/8-24 T30 Drive SetScrew 3 i1x '3 "^ U11-&16-E 1` SNLR 5/3/2022 3. M8-1.25 X 17mm (13mm/T30 Torx Drive) 4. 1:1 U11-B-16-E(S-5-U)[CCD] 4. Exam�}le Roof S-5!0 PRODUCTS ARE PROTECTED BY MULTIPLE U.S.AND FOREIGN PATENTS. SHEET NAME M VISIT OUR WEBSITEATWWW.S5.COM FOR COMPLETE INFORMATION ON ATTACHMENT PATENTS AND TRADEMARKS DETAILS SH EET SIZE 41 ANSI B 11"X 17" 1 ATTACHMENT DETAILS SHEET NUMBER PV-3 SCALE:NTS PV-2 (18)REC SOLAR REC460AA PURE-RX(460W)MODULES #(18)ENPHASE ENERGY IQ8X-80-M-US MICRO-INVERTERS TO UTILITY GRID - (03)BRANCHES OF 06 MODULES CONNECTED IN PARALLEL PER BRANCH = z�N(� BI-DIRECTIONAL UTILITY METER '"7� ET. 1-PHASE,3-W, HARVEST POWER LLC SYSTEM SIZE:-18 x 460W=8.28 kWDC - 120v1240v z9a+.SUNRISE,NY 117r IsuP 18 x 380VA=6.84 kWAC TEL LINE SIDE TAP TERRACE 98 3585 :(601)989-3535 [ (E)200A MAIN .-` SERVICE G - GISE)200A T 200A{ MAIN RE U � MAIN BREAKER NT G � (N)ENPHASE ! Z m COMBINER BOX ___ I _GROUNDING 3 V ELECTRODE SYSTEM MAIN HOUSE EXISTING _77 VERSION ER 06 MICRO INVERTERS IN BRANCH CIRCUIT#1 (2)10 AWG THWN-2 `95A WIRES -' �- 1'V _ORIPnoN DwrE (1)#6 THHN STRANDED GREEN `(N}AO DUCONNECT-A USEQ,V=SIBLE LOC.KAB_E ( BLDG,PERMIT OT(03/2025 0 [ T GROUND IN 1 PVC CONDUIT LABELED,40A FUSES, I 20A 240 VAC (N)JUNCTION 40A FUSES per—}—L- { ) — (E)20OA MAIN 5�(k 200A SERVICE PANEL '' GATEWAY _ _ (06)ENPHASE ENERGY M IQ8X-80-M-US MICRO-INVERTERS I _ — ( 77OMP ) T- m W(E)200A BREAKER _ -' BO ED TERMINATOR CAP ON LAST CABLE eT a — N CONNECTOR Q-CABLE(TYP) - ----- GARAGE (1}Q-CABLE p (3)#6 BLK RED THHN (2)#6 ELK RED THHN PROJECT NAME j (1)#6 THHN STRANDED (1)#6 WET THHN 06 MICRO-INVERTERS IN BRANCH CIRCUIT#2 (1)PV 6 BARE CU GND GREEN GROUND IN t"PVC (i)#6 THHN STRANDED W �I CONDUIT RUN GREEN GROUND IN CONDUIT RUNT PVC z I I i (3)98 BLK RED THHN LLI (n 1 ` I (H THHNSTRANDED -� (N)125A SOLAR GREEN GROUND IN 1"PVC U5 M O LOAD CENTER t CONDUIT RUN {.LI f`'J O !Alma 4 THROUGH TRENCH-65'-0" o Z CD c _ O [ Y 06 MICRO-INVERTERS IN BRANCH CIRCUIT#B_ i ,a In-E"v°v i ` Q LL t Z Z O j tL : ��f t (N)JUNCTION W_}P .! (n p J O I Bcx#z Z CI F Q i it li 20A co 0 O o O K ' ____ y _ .___ _m_e� _ BILL OF MATERIALS j U Q Q # - (12)ENPHASE ENERGY i EQUIPMENT QTY DESCRIPTION Q IQ8X-80-M-US MICRO-INVERTERS 1SOLAR PV MODULE _ 18 _REC SOLAR REC460AA PURE RX(460W)MODULES TERMINATOR CAP ON LAST CABLE I s 'INVERTER 18 'ENPHASE ENERGY I08X-80-M-US MICRO-INVERTERS CONNECTOR Q-CABLE(TYP) t i SHEET NAME COMBINER BOX 1 ENPHASE IQ COMBINER BOX r = JUNCTION BOXES 2 60GV,55A MAX,4INPUTS,MOUNTED ON ROOF FOR WIRE&CONDUIT TRANSITION THREE LINE DIAGRAM AC DISCONNECT 1 IAC DISCONNECT 60A FUSED,WITH 40Al2P FUSES,240V NEMA 3R,UL LISTED SHG°T 112€ (2)Q-CABLE (4)10 AWG THWN-2 SOLAR LOAD 1 125A SOLAR LORD CENTER ANSI B (1)PV 6 BARE CU GND (1)#6 THHN STRANDED ;CENTER GREEN GROUND 11"X 17" IN 1"PVC CONDUIT THREE LINE DIAGRAM SHEET NUMBER ;' SCALE: NTS PV-3 ELECTRICAL SHOCK HAZARD PHOTOYOLTAICSYSTEM :SOLAR PV SYSTEM EQUIPPED' COMBINER PANEL HARVEST SHUTDOWN TERMINALS ON LINE AND LORD DO NOT ADD LOADS SIDES MAY BE ENERGIZED IN HARVEST POWER LLC THE OPEN POSITION LABEL LOCATION: z941 SUNRISE ERan HIGHWAY IsuP S PHOTOVOLTAIC AC COMBINER(IF 7EL-(801)989-3555 APPLICABLE). - '� vie- LABELLOCATION: INVERTER(S),AC DISCONNECT(S),AC 3` TURN RAPID SHUTDOWN COMBINER PANEL(IF APPLICABLE). SALARELEtTNiC _ `a�X� °' ' SWITCH TO THE"OFF" PAS y POSITION TO SHUT DOWN ¢ G =� PV SYSTEM AND REDUCE ! z n SHOCK AY. IN THE AR 1 - 817 '.. °fI�WY VERSION _ --SCRIP of DATE REV.. BLDG-PERMIT 07103/2025 0 LABEL LOCATION ON OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE LABEL LOCATION: DISCONNECTING MEANS TO WHICH THE PV SYSTEMS UTILITY SERVICE ENTRANCEIMETER,INVERTERIDC ARE CONNECTED. DISCONNECT IF REQUIRED BY LOCAL AHJ,OR OTHER LOCATIONS AS REQUIRED BY LOCAL AHJ. POWER SOURCE OUTPUT CONNECTION DO NOT RELOCATE THIS PROJECT NAME OVERCURRENT DEVICE U LABEL LOCATION: Z ADJACENT TO PV BREAKER AND EBB W co .- OCPD(IF APPLICABLE). c 0 BUILDING SUPPLIED BY UTILITYco 0 GRID AND PHOTOVOLTAIC W z mo co C, Q cr SYSTEM � Z z o r W � o s F YW 6� � LL ® s Z o U o F LABEL LOCATION: CE SOLAR LOAD O CENTER u) o to o INTERIOR AND EXTERIOR DC CONDUIT EVERY 1O FT, _ C d F Z -� AT EACH TURN,ABOVE AND BELOW PENETRATIONS, - ON EVERY JBIPULL BOX CONTAINING DC CIRCUITS. 7 c) D_ Q U Q Z Q IN)PV MO DULES— • 0 0 , • II SHEET NAME (E)MAINSERVICEPANEL ( PLACARD& (INSIDE) WARNING LABELS 8 i 4• ' ' (E)MAIN SERVICE DISCONNECT(OUTSIDE) >{� _ SHEET SIZE LABEL LOCATION (E)UTILITY METER —(N)COMBINER BOX ANSI B AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF (N;AC DISCONNECT INTERCONNECTION, 1 1"X 1 71 LABEL LOCATION: SHEET NUMBER POINT OF INTERCONNECTION PV-4 (PER CODE:NEC690.56(B),NEC705.10,225-37,230.2(E)) 1. EACH MODULE TO BE GROUNDED USING THE SUPPLIED CONNECTION POINT PER Hi MANUFACTURER'S REQUIREMENTS.ALL SOLAR MODULES, EQUIPMENT,AND METALLIC COMPONENTS ARE TO BE BONDED. IF THE EXISTING GROUNDING HARVEST ELECTRODE SYSTEM CAN NOT BE VERIFIED OR IS ONLY METALLIC WATER PIPING, HARVEST POWER LLC IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSTALL A SUPPLEMENTAL ;S�E 29d TERRACE,HIGHWAY17 SLIP GROUNDING ELECTRODE. T 80»e93585 2. ALL PLAQUES AND SIGNAGE REQUIRED BY THE LATEST EDITION OF NATIONAL w z�IT, ELECTRICAL CODE. LABEL SHALL BE METALLIC OR PLASTIC, ENGRAVED ORy ` MACHINE PRINTED IN A CONTRASTING COLOR TO THE PLAQUE. PLAQUE SHALL lfiO_ BE UV RESISTANT IF EXPOSED TO SUNLIGHT. 3. DC CONDUCTORS SHALL BE RUN IN EMT AND SHALL BE LABELED,"CAUTION DC VERSION DESCRIPTION DATE `REV_ CIRCUIT"OR EQUIV. EVERY 5 FT. BLD6.PERMIT !CT1LJ2025 ' 0 4. EXPOSED NON-CURRENT CARRYING METAL PARTS OF ELECTRICAL EQUIPMENT _ SHALL BE GROUNDED IN ACCORDANCE WITH 250.134 OR 250.136(A). 5. CONFIRM LINE SIDE VOLTAGE AT ELECTRIC UTILITY SERVICE PRIOR TO CONNECTING INVERTER.VERIFY SERVICE VOLTAGE IS WITHIN INVERTER VOLTAGE OPERATIONAL RANGE. 6. OUTDOOR EQUIPMENT SHALL BE NEMA-3R RATED OR BETTER. PROJECT NAME 7, ELECTRICAL CONTRACTOR TO PROVIDE CONDUIT EXPANSION JOINTS AND w U ANCHOR CONDUIT RUNS AS REQUIRED PER NEC. w o � o - 8. ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL w m o MEANS DESIGNED AND LISTED FOR SUCH USE,AND FOR ROOF-MOUNTED W ? °2 o a SYSTEMS,WIRING MUST BE PERMANENTLY AND COMPLETELY HELP OFF OF THE :5. z } o -1 O ROOF SURFACE. NEC 110.2-110.41300.4 W U)tiJ O J UZ 9. ALL ROOF PENETRATIONS MUST BE FLASHED. SIMPLY CAULKING DOES NOT Z o(5 o S (n ,n O o 0 SUFFICE. a F I- z -' U Q Q Q 0 SHEET NAME ADDITIONAL NOTES SHEET SIZE ANSI B 11"X 17" SHEET NUMBER PV-5 REE Hiir 1 ♦ PURE-RX SERIES _ SOLAR`S MOST TRUSTED REC HARVEST HARVEST POWER M-C \ X 441 TJ nRRAGEHIGHINJA ZISLIP C!ItfCe- 88h if RECNf ,o, ry t Is v A � tnl ar gapi nP �. �FF�i 32mm da,sl s with 61 r ENI�IaE 1 _ H 6hly t M iyene- 171 � \\� 4 P 1 EC AL \ `\� d hl( ,, 7 ��A�� St bl M1EC4P If5CEtKSi'4 4 _z1 \ _. c e<mr„ ,gal' s - ae�d �m Ece_ez2 CPU�� --. = DES'CftPTI�V ERSOI OTN:E 234kg _4 Made:n e ' agapor ,aeasoremeots�emm \ x tad=Cade.R�ECxxaAAPm-RX 11 ... Power,-p'.P„.„(dip) 450 7t50 470 EEC612152021IEC61.a02_16,ULb173C 4t'aC ClassSartind-(Wj a1+10 Or'10 G,r.m IEf6 804 PIC IEc6ve: s-¢Mlst Nominal Power\'eirage-V,opj`J) 543 549 55.4 IEC62716 Amrnanra Pesistance Nominal Pax'erft+rrar[-I_(A) 8Po 838 8.49 11011925-2 !gait-:ay(ENI35 TICIas,E) m Dpen CIr 7tY�tage-V_tV) 65_I 053 65.6 IE112782 D,—,Me<h,,,—I Load _ IEC 612H-2 Hal,—(35mmj Shari Circuit Current-isr(A) 881 BOB 895 IEC6221 Le�beear..to ROHSEUB63;20'.5 Power Dens�ty(Wjmr? 216 223 226 IEC61 7 3 0-2 2 016 "Ire Gass C(asper UL-790) 'anel EfficercfiA=1 2i,6 221 22.6 ISD 14aa1,i509001.1EC 45:\;1,1-C62941 Fewer Output-P„,�@vpi 343 3`sa 3se C( O_ --- - PROJECT NAME Nomina!Pawer Ycitage-Y,g,,;V; 512 117 522 W 0 Nami Fewer Curr=-at-I_jAl 570 677 686 Declare. ` C) OP C i4 ft g (V) 613 616 5 _ �t3 Z Q SO,,C-tt A 11 7-7 723 (f} O raa-t?aa.'sa -- t4- v,-._ C se d.- a wt,a N nnalMedule opera T ce l-re. a4 (2°C) Q p r 0._ J'� ak- Y 8i -- nc-s>vs -g.�4" [ s. S.:r edinceda04Yr`m, e,eP C'7 V - ds dl wezkscsa.-sU eaz,m S°C 44j'{ E �} TanP t fi t FY: 024% C = LU -M O \ \ amF t Go-4%1 C of Z 0) CD Bperat enai te'nFe'atar¢ -40_a85Y „�..>., StartaaN REC PmTrset Tr< P tarecoeti+c- atedare"nea.awes Y �_ O l000v I.taneary Na ve: r Maximcm to=I dlf rt>• 7 JPa{713kgt-) System Sze Ali <25kW 255031,E ` z= P` O M :t tl dt ea'j: -4000 Pd(4D7k&'mz7" PrMurtW t Par I P P II 33 Y L Cn h y'irzl 20 25 2 5 Pan G 40k GPrh:gh b _-+ne.. 44(iBp Iletsl _ LU � O J_ Z Max serest_e.a[Pg. 25A Pie W _ty(yn) 25 — 25 Z to Max reverse currerri: 25A La6arN'arrani}jyrsj 0 2n 10 .-nets perlabmtruck. 660(20 pa1letsi p 0 O ~ 0 n 0 0 Q VA V - 5 Gez?gnieaaa toe,l5 isafe,rf P w,, 1 98% 9856 25 .. € at Rad, .e tN:ma�eetP„eatsT_ .1, Z A ID a t azs�, ers�s azsss F .env s % 9% 9% ����\� ,, _ - _ A Table`rvm: fkraacanelWJm'}a SHEET NAME SPEC SHEET SHEET sizE ANSI B E a RECS 1 PTE LTD > ^ I v fighq \� d -n L996 - [ IF $ - 8Y tdhiatdt P 3 C 20T 5 =h A'.14 �' �l\ fN It I -- d -, carbonfaot nt nih_ol-m a.asalarpareisYm u esHeadga- aed.Na xaf x�th aP agora Sngapere6.Z32 p -_era cNr = pos[pr=cgraupcom w+vw.e.groua.com _ - - headquarterz'n5`ngapare RECe„ala�reg.onaihubs'nt;arthAmer<a Eurape,anc Asia Pacinc. _jjj _ SHEET NUMBER PV-6 HARVEST _. U •� -. HARVEST POWER LLC wallSOLARMONT1 zsal SUNRISE HIGHWAY IsuP TERRACE,NY 11752 T EL'.(801 j 98&3585 =tE:'atk'f.1'a1'.2SC SOLARI`IOUNT is the professionals'choice for residential PV mounting applications. Every aspect of the � c system is designed for an easier.faster installation experience.SOLARIVIOUNT is a complete solution with revolutionary universal clamps,FLASHKIT PRO,full system UE 2703 certification and 25-year warranty.Not only is SOLARtv1QUNT easy to install,but best-in-class aesthetics make it the most attractive on any block! 7 RSION { 1 1t FG "ION gkT� REV- S F 1 Si@G.P€RMiT _—32— `= 0 , Fi i PROJECT NAME �: II W We,,&Improved: U l - C:) O S, O Q p Y C, o O Z >- o A e_ D ZLji o f Li W ED o Z Z u) C� o \\\` 0000 � 0 ` 2 1— Q .. a_ O k NOW FEATURING FLASHKIT PRO NOW WITH UNIVERSAL MIDCLAMPS REVOLUTIONARY NEW ENDCLAMPS a = Q � am—,:dat- So.m-FImn tleafir—, _n. I i,,nil ln,tUjiAcrn Q � rc�rua xs 0SHED SEAL rz�-xc:ovv 0.e iae.a.-P-n m,blka e he e�. SHEET NAME i!' k • r E I i I I ' ! I ® EI i "1 SPEC SHEET E SHEET SIZE ANSI B i�• � 1 �• 1 � �• 1 1 t. 1 # ,• i � 1 11' X17" SHEET NUMBER PV-7 - Unirac State Letter-NY NA V ST Teton WOE 155724 HARVEST O WERLLGTech *( ec +C August 12,2024 2941 SUNRISE HIGHWAY ISLIP TERRACE.NY 11752 ' TEL(801)989-3585 August 12,2024 - Metal Roof:Standing Seam Attachments,PM-9000s,and PM Adjust Slotted Cct Tile Roof:Solar hooks,Flashkit Tile Replacement(TR) Unirac i Attn:Engineering Services Department The U-Builder Tool should be used under the responsible charge of a registered m 1411 Broadway Boulevard NE professional engineer required by the authority having jurisdiction.The design tool m( z, Albuquerque,NM 87102-1545 and Unirac do not evaluate the existing roof structure,or the PV panels themselves. —4{ _ z y TEL:(505)242-6411 See the construction and installation drawings and manuals for additional ' information provided by Unirac. � RE: ENGINEERING CERTIFICATION LETTER FOR THE UNIRAC SOLARMOUNT(SM) G� .417 ROOF PV PANEL SUPPORT SYSTEM Sincerely, '^ t � VERSION DAT ,`�4F N��t� - .P?t9N OH?E REV, STATE:NEW YORK Tectonic tP *Q A. Gr, OQ BLDCPERMIT 07:0312025 o TECTONIC WORK ORDER#:12557.25 Coo' The Unirac SOLARMOUNT(SM)Photovoltaic Panel Support System is a proprietary e w framed photovoltaic panel support system that is installed on a roof. Tectonic z Engineering Consultants, Geologists & Land Surveyors, D.P.C. (Tectonic) has reviewed the SM design methodology along with the U-Builder tool;a Unirac online °?t249 design tool.The review included the following SM products,SM Light,Heavy Duty, s1° 08/12/2024 and Standard rail with both the standard and pro hardware. Antonio A.Gualtieri,P.E. Tectonic has determined that the design is a rational approach and follows the Executive Vice President structural requirements of the following reference documents: Codes/Standards: PROJECT NAME 2020 Building Code of New York State. W 2018 International Building Code by International Code Council. U ASCE/SEI 7-16 Minimum Design Loads for Buildings and Other Structures,by W American Society of Civil Engineers with provisions from SEAOC PV-2-2017. co 0 0 2020 Aluminum Design Manual,by Aluminum Association. J This letter certifies that the structural analysis of the racking members,connections, LLJ� U'i o O and components directly related to Unirac's system are in compliance with the Z o a 0 above codes. The design methodology is acceptable under components and Z} 'r - Cn cladding loads associated with the building's roof structure when the system is 0 z o� �- LL O installed in accordance with manufacturer specifications.If the loading criteria does not meet Unirac's specifications, owner shall contact Unirac for a site-specific W U)W o �_ Z certification. Z o 0 o OLO C:) 0 Attachments approved for the SM system to the structure include the following W U and is installed per Unirac's U-Builder report and installation guides: n- Q > U Q Shingle Roof:L-Foot Flashkit Pro,Standoffs,Flashloc Comp,Flash Loc Duo, and Flash Kit Pro SB SHEET NAME Project Contact Info Project Contact Info SPEC SHEET 1279 Rou@ 300 1 N%Ourgh,NY 12550 1271 Rau@ 300 1 N1,0ofgl:.NY 12550 845.567.6656 Tel 1 845.567.8703 Fax 845.567.e856 Tel 1845.56'8703 F. SHEET SIZE todotootelf engmeenng— page 2 of 2 ANSI B Equal pporheriE.mm Equal Opponerity Employer Equal opporiutnty Employer 11"X 17" SHEET NUMBER PV-8 PHOTOVOLTAIC ROOF MOUNT SYSTEM 18 MODULES-ROOF MOUNTED - 8.28 kWDC, 6.84 kWAC .. ,. 5-S 6" Br-f 52'1� 505 SKUNK LN CUTCHOGUE NY 11935 USA , HARVEST POWER LLC --- - - 2941 SUNRISE HIGHWAY ISLIP SYSTEM SUMMARY: • GOVERNING CODES. SHEET INDEX TERRACE,NY 11752 ��[��qR TEL:(801)989-3585 (N) 18-REC SOLAR REC460AA PURE-RX(460W) MODULES --- q C 2017 NATIONAL ELECTF.ICAL CODE PV-0 COVER SHEET {� �y websitemw'w.harvestpower_net (N) 18-ENPHASE ENERGY IQ8X-80-M-US MICRO-INVERTERS PV-1 SITE PLAN WITH ROOF PLC L (N) 02-JUNCTION BOXES 2020 NEW YORK STATE UNIFORM CODE ` E K O (E)200A MAIN SERVICE PANEL WITH (E)200A MAIN BREAKER 2020 NEW YORK STATE RESIDENTIAL CODE PV-2 ATTACHMENT DETAILS I I�� � C°� (E)200A MAIN SERVICE DISCONNECT WITH (E)200A MAIN BREAKER PV-3 THREE LINE DIAGRAM ,, c PV-4 PLACARDS&WARNING AB •�� I (N) 60A FUSED AC DISCONNECT PV-5 ADDITIONAL NOTES (N) ENPHASE IQ COMBINER BOX PV-6+ SPEC SHEETS ��- (N) 125A SOLAR LOAD CENTER y �298q� O DESIGN CRITERIA: � C'�� � VERSION ROOF TYPE: -STANDING SEAM METAL DESCRIPTION DATE REV. ROOF CONDITION: OK - - ROOF FRAME: -2"X10" RAFTERS @16" O.C. (MAIN HOUSE) BLDG.PERMIT 07/03/2025 0 ROOF FRAME: -3.5"X8" RAFTERS @24"O.C. (GARAGE) STANDING SEAMS:-@12" O.C. SEAMS SPACING STORY:-ONE STORY SNOW LOAD : -25 PSF WIND SPEED :- 130 MPH WIND EXPOSURE:-C GENERAL NOTES: ARRAY /� 1. INSTALLATION IN ACCORDANCE WITH MANUFACTURER ARRA I�/ LOCATIONS RECOMMENDATIONS. PROJECT SITE 2. ENGINEER TO INSPECT PROJECT AFTER INSTALLATION AND CERTIFY COMPLIANCE. Fiberglass 3. PROJECT TO BE INSTALLED WITH CODE COMPLIANT RACKING INSTRUCTIONS FOR UNI-RAC SOLAR MOUNT 25 i 1p Service PROJECT NAME SYSTEM. W 4. FOLLOW BALLASTING SCHEDULE ON ROOF PLAN. U 5. HARVEST POWER, LLC., THE SOLAR INSTALLATION I uJ r EAST CUTCHOG E Kru _ Q CONTRACTOR, COMPLIES WITH ALL LICENSING &ALL PSG' 0 � o � RELATED REQUIREMENTS OF THE GOVERNING Lo o MUNICIPALITIES AND THE LOCAL ELECTRIC UTILITY LU AHJ'S. IY Z m o Q 6. THIS PROJECT WILL COMPLY WITH THE CURRENT NEC I *> 0 Y - 4 0- 0 REQUIREMENTS INCLUDING ARTICLE 690 SOLAR z >- p -i PHOTOVOLTAIC PV SYSTEMS. F- :D z o j_ LL 7. THE ROOF WILL HAVE NO MORE THAN A SINGLE LAYER W W �o J OZ OF ROOF COVERING IN ADDITION TO THE SOLAR EQUIPMENT. Z o (5 o 505 Skunk Ln, Lo o o o 0 8. INSTALLATION WILL BE FLUSH-MOUNTED, PARALLEL TO AND NO MORE THAN 6.5"ABOVE ROOF CUtCI l ue NY a__ (, 2 9. MAINTAIN A MINIMUM OF 18"CLEARANCE AT RIDGE Z AND AT ONE GABLE EAVE. D 0- Q 11935, United States > c) Q 10. THIS DESIGN COMPLIES WITH 130 MPH WIND Q REQUIREMENTS OF THE RESIDENTIAL CODE OF N.Y.S AND ASCE 7-16. . 11. WHEREVER THE ROOF PLAN DOES NOT COMPLY WITH SHEET NAME ACCESS AND VENTILATION REQUIREMENTS OF THE 'e COVER SHEET UNIFORM CODE, HARVEST POWER PROPOSES THAT G ALTERNATIVE VENTILATION METHODS WILL BE EMPLOYED. REVIEW AND APPROVAL SHALL BEAT THE SHEET SIZE DISCRETION OF THE MUNICIPALITY IN WHICH THIS l -_ - ANSI B DOCUMENT HAS BEEN FILED. 12. THE DESIGN PLANS COMPLY WITH THE 2020 NEW 11" X 17" YORK STATE UNIFORM FIRE PREVENTION AND 1 AERIAL PHOTO 2 VICINITY MAP RESIDENTIAL BUILDING CODE. SHEET NUMBER PV-0 SCALE: NTS PV-0 SCALE: NTS PV_o MODULE TYPE, DIMENSIONS & WEIGHT NOTE:-THERE ARE NO FENCE ROOF ACCESS AREA: NUMBER OF MODULES= 18 MODULES IN THIS PP,OPERT SHALL BE LOCATED IN AREAS THAT DO NOT REQUIRE THE PLACEMENT OF GROUND j AND GATE Y MODULE TYPE= OVER OPENINGS SUCH AS WINDOWS OR DOORS,AND LOCATED AT STRONG POINTS OF =5 MODULE WEIGHT= 0.0 LBS/22.7 SOLAR REC460AA PURE-RX(460W) MODULES BUILDING CONSTRUCTION IN LOCATIONS WHERE THE ACCESS POINT DOES NOT MODULE DIMENSIONS= 68.0"X 47.4" 22.38 SF CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS,WIRES OR SIGNS. = UNIT WEIGHT OF ARRAY=2.23 PSF 'l. HARVEST[ !"717 HARVEST POWER LLC 2941 SUNRISE HIGHWAY ISLIP TERRACE,NY 11752 �;-QED n TEL:(801)989-3585 site:www.harvestpowernet \ po C3� e EL i� ! � I (E) DETACHED STRUCTURE �)44 N E VERSION SCRIPTION DATE REV. \0A BLDG.PERMIT 07/03/2025 0 do '/ l�',, �` �11 "); 1;r �; 'r',` 'ray'✓,) s`'�=' t`-; \ N f - - \ V r- �'y PROJECT NAME \. ,.i �: '``,'*..� \S. •,�!r`i-1 tir lY F1'v� -f"', r( LLJ Q w Z 0) o f- (E)TREE (TYP.) z } o \ ` oz F- LLEXISTING - ODRIVEWAY // u rn\ \/ Q- U �TRENCH DETAIL v Q Q � O \�\ SEE ENLARGED SHEET NAME VIEW ON PV-1.1 z \\� �\ SITE PLAN WITH ROOF PLAN 00 (x i SHEET SIZE 6"MIN SAND ANSI B \\\ 1"SCH 40 PVC CONDUIT NOTE:-TRENCH CONDUIT TO i\ 11�� X 17" SITE PLAN WITH ROOF PLAN HAVE 24"MINIMUM BURIAL \�\ DEPTH UNDER DRIVEWAY \\i SHEET NUMBER �177:7\ PV-1 MODULE TYPE, DIMENSIONS & WEIGHT ROOF ACCESS AREA: SHALL BE LOCATED IN AREAS THAT DO NOT REQUIRE THE PLACEMENT OF GROUND NUMBER OF MODULES = 18 MODULES OVER OPENINGS SUCH AS WINDOWS OR DOORS,AND LOCATED AT STRONG POINTS OF MODULE TYPE= REC SOLAR REC460AA PURE-RX(460W) MODULES BUILDING CONSTRUCTION IN LOCATIONS WHERE THE ACCESS POINT DOES NOT MODULE WEIGHT=50.0 LBS/22.7 KG. CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS,WIRES OR SIGNS. - MODULE DIMENSIONS = 68.0"X 47.4"=22.38 SF UNIT WEIGHT OF ARRAY=2.23 PSF «<P "'f"77Z HARVE T�" �... e°.� : HARVEST POWER LLC 2941 SUNRISE HIGHWAY ISLIP 2 TERRACE,NY 11752 (E)200A MAIN SERVICE DISCONNECT TEL: w.h 9estpo 5 '�/ s > Zm \� website:www.harvestpowernet WITH (E)200A MAIN BREAKER �� \ ,,-\ (N) 1" PVC CONDUIT 'i (OUTSIDE) �� � A RUN 7/8"ABOVE ROOF �G . �PEi i O� (N) JUNCTION BOX(TYP (E) UTILITY METER .) M �n \ J r•�. (N)60A FUSED AC DISCONNECT /�, zH • - \\ r i ,� (N) ENPHASE IQ COMBINER BOX VERSION DESCRIPTION DATE REV. BLDG.PERMIT 07/03/2025 0 (E)200A MAIN SERVICE PANEL WITH (E)200A MAIN BREAKER ` (INSIDE) \ ROOF#1 \ (06) REC460AA PURE-RX(460W) \ �l RAFTERS= 2"X10"@16" O.0 \ STANDING SEAMS= @12"O.0 \ G 161°AZIMUTH, 37°TILT PROJECT NAME 2 (06) ENPHASE ENERGY IQ8X-80-M-US `�� (w j MICRO-INVERTERS \ Z w U) 0 0 \ o cn LoCO o O w \� � Zo)C J O 191-o 0- O �- \\ = z CD O TRENCH DETAIL \ (E) GARAGE Z CD z o O 1"SCH 40 PVC COIJDUIT \ ` \ cooLo O o_ O X\ \\, TRENCH ^85'-0" \\ i \ - p I.-_ z _ \� \ (N) 125A SOLAR LOAD CENTER00 \\ y e e e 0 i \W � 6' SHEET NAME MIN SAND e • 1"SCH 40 PVC CONDUIT ROOF#2 ° e ° SITE PLAN WITH �\ (12) REC460AA PURE-RX(460W) ROOF PLAN \\ NOTE:-TRENCH CONDUIT TO RAFTERS= 3.5"X8"@24" O.0 SHEET SIZE HAVE 24"MINIMUM BURIAL STANDING SEAMS= @12" O.0 ANSI B DEPTH UNDER DRIVEWAY 161°AZIMUTH, 37°TILT 11" X 17" SITE PLAN WITH ROOF PLANe4,4, (12) ENPHASE ENERGY -INVERTERS 1MICRO-INVERTERS SHEET NUMBER SCALE: 1/16"= 1'-0" PV-1 .1 a i - I i S-5-U HARVEST" TOP HARVEST POWER LLC I.Y c 2941 SUNRISE HIGHWAY ISLIP NY 11752 `o`erD '��TERPACE, L:(801)989-3585:www.ha vest owernet M8-1.25 Threaded Hole ` } 0 0.90[22.9] � V7 1 'u= + 0.40[10.2] �j� 029II 11 Q� 0.54 [13.7] F N ENq VERSION PBLDG.PERMIT DATE REV. ��V .75 [19.1] 07/03/2025 0 Left Front Right 1.50 [38.1] M8-1.25 Threaded Hole 1.50 [38.1] 1.13[28.6] PROJECT NAME 0.31 [7.9] W 1. U (4x)3/8-24 Threaded Hole z �---�-0.38 [9.5] 0.55 [14.0 I--1.25[31.8]--I p � o 1.50[381] W _ � o O= z rn o Q ❑ y � n- O 2. 2 z } cc) -icn f- D Z o } LL. MATERIAL: w LLj O 0 METAL ROOF INNOVATIONS,LTD. 000 Series AL 8750 WALKER RD Z Ln o EST ASSEMBLY Wr: COLORADO SPRINGS,CO 80908 Cn C)LO O o O 0.390lbs 719-a95-0518 O = �- General Notes: 1, HARDWARE: 719-495-0045(FAX) O- U ❑ � z = 1 . S-5-U rimstium y TITLE S-5-U [CCD] ZU) Q 3. DRAWING NO. Q 2. 0.9" 3/8-24 T30 Drive SetScrew U11-B-16-E WSNLRA5/3/2022 ❑ 3. M8-1.25 X 17mm (13mm/T30 Torx Drive) �4 SCALE1:1 'LE NAME U11-B-16-E (S-5-U)[CCD] 4. Example ROOF S-5!®PRODUCTS ARE PROTECTED BY MULTIPLE U.S.AND FOREIGN PATENTS. SHEET NAME VISIT OUR WEBSrrE AT WWW.S-5.COM FOR COMPLETE INFORMATION ON ATTACHMENT PATENTS AND TRADEMARKS DETAILS SHEET SIZE ANSI B 11" X 17" 1 ATTACHMENT DETAILS SHEET NUMBER PV-3 SCALE: NTS P v-2 (18) REC SOLAR REC460AA PURE-RX(460W) MODULES (18) ENPHASE ENERGY IQ8X-80-M-US MICRO-INVERTERS TO UTILITY GRID (03) BRANCHES OF 06 MODULES CONNECTED IN PARALLEL PER BRANCH L1 Lz N BI-DIRECTIONAL M UTILITY METER HARVEST' 1-PHASE,3-W, HARVEST POWER LLC SYSTEM SIZE-.- 18 x 460W- 8.28 kWDC 120V/240V 2941 SUNRISE HIGHWAY ISLIP 18 x 380VA= 6.84 kWAC LINE SIDE TAP �EO TERRACE,NY 11752 (e TEL:(801)989-3585 - SEERVICEMAIN % PEL C st site:www.harve ower.net DISCONNECT C) k 200A - W/(E)200A N EG7 MAIN BREAKER --'I (N)ENPHASE COMBINER BOX GROUNDING', ELECTRODE SYSTEM 8`17 MAIN HOUSE i L__� , 0� `� 06 MICRO INVERTERS IN BRANCH CIRCUIT#1 I EXISTING _ VERSION (2)10 AWG THWN-2 15A I(1)#6 THHN STRANDED GREEN (N)AC DISCONNECT 60A WIRES DESCRIPTION DATE REV. GROUND FUSED,VISIBLE LOCKABLE I BLDG.PERMIT 07/03/2025 0 LABELED,40A FUSES, I IN 1"PVC CONDUIT 20A 240 VAC j I I (N)JUNCTION o I Box#1 40A 40A FUSES 1 ----------- o ------- �—�-- �\ L1 L1 L2 L2 r� I L2 L2 M` IQ N N j 0 i (E)200A MAIN GATEWAY I 200A I SERVICE PANEL (06)ENPHASE ENERGY �- -- ------G------ -- -------- I W/(E)200A IQ8X-80-M-US MICRO-INVERTERS i I MAIN BREAKER --- ---- --� -- - -------------- r = _= G (BOTTOM FED) TERMINATOR CAP ON LAST CABLE CONNECTOR Q-CABLE(TYP) i -------" ---� G I E_a- J GARAGE j (3)#6 BLK RED THHN (2)#6 BLK RED THHN (1)Q-CABLE I 1 #6 THHN STRANDED PROJECT NAME 06 MICRO-INVERTERS IN BRANCH CIRCUIT#2 (1)PV 6 BARE CU GND ( ) (1)#6 WHIT I 3REEN GROUND IN 1"PVC (1)#6 THHN STRANDED LjJ I CONDUIT RUN GREEN GROUND IN 1"PVC U CONDUIT RUN I Z I (3)#8 BLK RED THHN W (1)#6 THHN STP,ANDED Q O J I GREEN GROUND IN 1"PVC — CD (N)125A SOLAR _ = I I CONDUIT RUN c/) O O ti I ti ti I LOAD CENTER THROUGH TRENCH-85'-0" W CO CD -�------- ------------ ----- ; z m oo Q m- - - --- - CC Y 0- O 06 MICRO-INVERTERS IN BRANCH CIRCUIT#3 i M* IQ-Envoy I G z CD J I I I I 15A I LL j (N)JUNCTION . . I BOX#2 I W U) D CD _J Z 20A j (D cc:)) ~ L1 L1 I L0 O O O ti ti 1 1 Lz L2 20A z r ��-------- ��'------------ �--�----- (12)ENPHASE ENERGY L1 L1 I BILL OF MATERIALS > U Q Q IQ8X-80-M-US MICRO-INVERTERS L2 L2 EQUIPMENT QTY DESCRIPTION Q I SOLAR PV MODULE 18 REC SOLAR REC460AA PURE-RX(460W)MODULES TERMINATOR CAP ON LAST CABLE I INVERTER 18 ENPHASE ENERGY IQ8X-80-M-US MICRO-INVERTERS CONNECTOR Q-CABLE(TYP) iI SHEET NAME _ _ G N i COMBINER BOX 1 ENPHASE IQ COMBINER BOX ------------ ---� JUNCTION BOXES 2 600V,55A MAX,4 INPUTS, MOUNTED ON ROOF FOR WIRE&CONDUIT TRANSITION THREE LINE DIAGRAM I- AC DISCONNECT 1 AC DISCONNECT 60A FUSED,WITH 40A/2P FUSES,240V NEMA 3R, UL LISTED SHEET SIZE (2)Q-CABLE (4)10 AWG THWN-2 SOLAR LOAD (1)PV 6 BARE CU GND (1)#6 THHN STRANDED CENTER 1 125A SOLAR LOAD CENTER ANSI B GREEN GROUND - ---- — -- -- - IN 1"PVC CONDUIT 11" X 1 7" 1 THREE LINE DIAGRAM SHEET NUMBER SCALE: NTS PV-3 4" WARNING AWARNING - - -- ELECTRICAL SHOCK HAZARD PHOTOVOLTAIC SYSTEM SOLAR PV SYSTEM EQUIPPED ' COMBINER PANEL WITH RAPID SHUTDOWN TERMINALS ON LINE AND LOAD DO NOT ADD LOADS HARVEST SIDES MAY BE ENERGIZED IN ---- - HARVEST POWER LLC THE OPEN POSITION LABEL LOCATION_ _ 2941 SUNRISE HIGHWAY ISLIP PHOTOVOLTAIC AC COMBINER(IF TERRACE,NY 11752 - — — APPLICABLE). C e .,�a` .1�'.,TEL:(801)989-3585 LABEL LOCATION: ''� E www.ha-,stpower.net INVERTER(S),AC DISCONNECT(S),AC 3 �. COMBINER PANEL(IF APPLICABLE). TURN RAPID SHUTDOWN SWITCH TO THE"OFF" SOLAR ELECTR VC n P PANELS - POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY. �9817RAPID SHUTDOWN SWITCH Q _ -" VERSION • ■ • / ■ PV SYSTEM DESCRIPTION DATE REV LABEL LOCATION: BLDG.PERMIT 07/03/2025 0 ON OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE LABEL LOCATION: DISCONNECTING MEANS TO WHICH THE PV SYSTEMS UTILITY SERVICE ENTRANCE/METER, INVERTER/DC ARE CONNECTED, DISCONNECT IF REQUIRED BY LOCAL AHJ,OR OTHER LOCATIONS AS REQUIRED BY LOCAL AHJ. AI/YARNING— POWER SOURCE OUTPUT CONNECTION DO NOT RELOCATE THIS PROJECT NAME OVERCURRENT DEVICE LLI LABEL LOCATION: U --- Z ADJACENT TO PV BREAKER AND ESS 0 OCPD(IF APPLICABLE). - - _ _ _ -_ _ C) BUILDING SUPPLIED BY UTILITY D o 0 GRID AND PHOTOVOLTAIC � z co CD J T- O Q SYSTEM o z - o a- o WARNING: cn r CD• • • ' I- � Zo > LL . • ■ SOURCEW � DoJ_ Z LABEL LOCATION: C31cc Z O O (N)SOLAR LOAD � Lo O O O CENTER W Q = r INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, U AT EACH TURN,ABOVE AND BELOW PENETRATIONS, _ C 1-- Z ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. Z 0 :) _ U Q Q Z Q (N)PV MODULESPHOTOVOLTAIC AC DISCONNECT ---_ SHEET NAME (E)MAIN SERVICE PANEL ----4METER PLACARD & MAXIMUM AC OPERATING NOMINAL . OPERATING . -. ' VOLTAGE: CURRENT:. 44 AMPS,' . (INSIDE) WARNING LABELS C I (E)MAIN SERVICE DISCONNECT(OUTSIDE) SHEET SIZE LABEL LOCATION: ANSI B AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF (E)UTILITY (N)COMBwER BOx(N)AC INTERCONNECTION. 11" X 17" LABEL LOCATION: SHEET NUMBER POINT OF INTERCONNECTION (PER CODE: NEC690.56(B), NEC705.10,225.37,230.2(E)) PV-4 } 1. EACH MODULE TO BE GROUNDED USING THE SUPPLIED CONNECTION POINT PER ' MANUFACTURER'S REQUIREMENTS. ALL SOLAR MODULES, EQUIPMENT, AND METALLIC COMPONENTS ARE TO BE BONDED. IF THE EXISTING GROUNDING HARVESTr:j',I L''� ELECTRODE SYSTEM CAN NOT BE VERIFIED OR IS ONLY METALLIC WATER PIPING, HARVESTPOWERLLC� IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSTALL A SUPPLEMENTAL -��� �q 941TERRISE,NY117YISLIP C TERRACE,NY 11752 GROUNDING ELECTRODE. E� K 'Si TEL:(801)989-3585 :www.harvestpowernet 2. ALL PLAQUES AND SIGNAGE REQUIRED BY THE LATEST EDITION OF NATIONAL :S ELECTRICAL CODE. LABEL SHALL BE METALLIC OR PLASTIC, ENGRAVED OR MACHINE PRINTED IN A CONTRASTING COLOR TO THE PLAQUE. PLAQUE SHALL OQ� BE UV RESISTANT IF EXPOSED TO SUNLIGHT. a�NE\N 3. DC CONDUCTORS SHALL BE RUN IN EMT AND SHALL BE LABELED, "CAUTION DC VERSION DESCRIPTION DATE REV. CIRCUIT" OR EQUIV. EVERY 5 FT. BLDG.PERMIT 07/03/2025 0 4. EXPOSED NON-CURRENT CARRYING METAL PARTS OF ELECTRICAL EQUIPMENT SHALL BE GROUNDED IN ACCORDANCE WITH 250.134 OR 250.136(A). 5. CONFIRM LINE SIDE VOLTAGE AT ELECTRIC UTILITY SERVICE PRIOR TO CONNECTING INVERTER. VERIFY SERVICE VOLTAGE IS WITHIN INVERTER VOLTAGE OPERATIONAL RANGE. 6. OUTDOOR EQUIPMENT SHALL BE NEMA-3R RATED OR BETTER. PROJECT NAME w 7. ELECTRICAL CONTRACTOR TO PROVIDE CONDUIT EXPANSION JOINTS AND U ANCHOR CONDUIT RUNS AS REQUIRED PER NEC. w �- o 0 o 8. ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL ui o 0 w MEANS DESIGNED AND LISTED FOR SUCH USE, AND FOR ROOF-MOUNTED � z m o Q � , O SYSTEMS, WIRING MUST BE PERMANENTLY AND COMPLETELY HELP OFF OF THE z � o � o ROOF SURFACE. NEC 110.2 - 110.4 / 300.4 z o LL wU o z 9. ALL ROOF PENETRATIONS MUST BE FLASHED. SIMPLY CAULKING DOES NOT z o o SUFFICE. 0 Ln o o o z U Q Q Q SHEET NAME ADDITIONAL NOTES SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-5 REE ALPHA PLIRE-RX 5ERIE5 15, REC SOLAR'S MOST TRUSTED REC ..O SOLAR'S MOST TRUSTED VEST -�R -D "'kVST POWER LLC �P9 Tj7fJE HIGHWAY ISLIP GENERAL DATA "�225 � E,NY 11752 7� e: 88half-cut REC bifacial,heterojunctioncells Cell type: + ��g n -' L 989-3585 yP with lead-free.gapless technology 7 web ° rvest ower.net 1 Glass: 3.2 mm solar glass with anti-reflective surface treatment 0 s --3�a I in accordance with EN 12150 Backsheet: Highlyresistantpolymer O Frame: Anodized aluminum(black) i+ r, - 4-part,4 bypass diodes,lead-free ALPHA Junctiorbox RAC IP68 rated,inaccordancewith IEC 62790Op Conneclors: Staubli MC4 PV-KBT4/KST4(4 mm') E I tie g in accordance with IEC 6285Z IP68 only when connected III I Cable: 4 mm'solarcable,1.7-1.7 m I rlis,as PURE-RX 5ERIE5 nac05x3ce m(2. 8ml) Dimensions: 1728 x 1205 x 30 mm(2.OB m') --EN 50618 VERSION - s us sera DESCRIPTION DATE REV. Weight: 23.4 kg PRODUCT SPECIFICATIONS Origin: Made in Singapore `--- ` - - `-------- BLDG.PERMIT 07/03/2025 0 Measureme is in mm ELECTRICAL DATA Product Code':RECxxxAA Pure-RX CERTIFICATIONS Power Cutput-P�,(Wp) 450 F,5.3 470 IEC 61215:2021,IEC 61730:2016,UL 61730 Watt Cl sSorting-(W) 0/+10 0/«I0 IEC62804 PID IEC61701 Salt Mist Nominalpower Voltage-V,e(V) 54.3 55.4 IEC62716 Ammonia Resistance NominalPowerCurrent-Is,A,(A) 8.29 8.49 1S011925-2 Ignitabilit y(EN 1350 1-1 Class E) ® Open Ci;cuit Voltage-Va(V) 65.1 65.6 IEC62782 Dynamic Mechanical Load IEC61215-2:2016 Hallstone(35mm) ShortCicuitCurrent-Isc(A) 8.81 8.88 8.95 IEC62321 Lead-freeacc.to RoHS EU 863/2015 PowerCensity(W/mg 216 221 226 IEC617302:2016 Fire Class C(as per UL 790) Panel Eficiency(%) 21.6 22.1 22.6 15014001,1509001,IEC 45001,IEC 62941 ---- - take PowerCutput P�x(Wp) 343 350 358 �F„ s� e<mww, PROJECT NAME NominalPower Voltage-V_IV) 51.2 51.7 52.2 0 NominalPowerCurrent-IM,(A) 6.70 6.77 6.86 N"g` W Z Declare. U Open Ci;cuit Voltage-V,IV) 613 61.6 61.8 t Z Short Circuit Current-Ix(A) 7.11 7.17 7.23 TEMPERATURE RATINGS' "3 LLJ Vatuesattandard test conditions(STC:air mass AM 1.5,irradiance1000W/m2,temperature25'Cj,based en a productionspreadwith a Nominal Module Operating Temperature: 44'C(t2°C) !�_^ O toleranceofp_.V,&Lx t3%withinone watt class.Nominal module operating temperature(NMOT:air mass AM 1.5,imadiance800WJm', Temperature coefficient P�„x: -0.24%/"C v/ coD O COMPACT �• PANEL temperahre ArC,windspeedl m/s),*Where xxx indicates the nominal power class(P,,j at STC above. O Temperature coefficient ofV.: -0.24%/-C 11) _ Co O MAXINUMRATINGS WARRANTY Q Z CA O Q Temperature coefficient oflsr: 0.04%/"C _I O Operational temperature: -40...+85"C Standard REC ProTrust O 'Th e temp era tune coefficients stated are linear values ec Maximunsystem vol tage: 1000V Installed by an REC No Yes Yes G Z >- 00 J 9 • R CertlfiedSolarProfessional a Maximum test load(front): -7000Pa(713kg/mz)' DELIVERY INFORMATION �, Z CD >-' IL COMPATIBLE • . . System Size All 425kW 25 SOOkW z Panels per pallet: 33 �-- (- Maximuntestload(rear): 4000Pa(407kg/m). Product Warranty(yrs) 20 25 25 N Panels per 40ItGP/high cube container. 594(18 pallets) W U) D CD J Z Maxseresfuserating: 25A Power Warranty(yrsj 2S 25 25 Z to Ur O Labor rs 0 25 10 Panels per13-6mtruck: 660(20pallets) " O O Max revwse curren t: 25A Warranty ) a CD Ln O O installation manual for mounting instructions. Power in Year 1 98% 98% 98% LOW LIGHT BEHAVIOUR o OI- ;",. (I Design load-Test load/1.5(safety factor) Annual Degradation 025% 025% 025% 9 U d I • "'" Typical low irradiance performance of module at STC: d, U Z Power in Year 25 92% 92% 92% q = 25 • The REC ProTrust Warranty is oniyavaiiable on panels purchased oL a- .. Q .RoTRusT through an REC Certified Solar Professional installer.Warranty \ U Q conditionsapply-See www.recgroup.com for more details. ¢ Joe LEAD-FREE ELIGIBLE ROHS COMPLIANT Availabl from: - R,ffi MadancetWpn') SHEET NAME t )s SPEC SHEET on SHEET SIZE I ANSI B Founded n 1996,REC Group isan international pioneering solar energy company dedicated to empoweriNcorisumers j REC SoIarPTE.LTD. with clear,affordable solar power.As Solar's Most Trusted,REC is committed to high quality,innovation,and a low 20 Tuas South v REC I ,sty > W • - +++ _ ° carbon footprint in the solar materials and solar panels it manufactures.Headquartered in Norway with operational ! Singapore63731214 • "-� 111 X 7� ;� ,,, - . -, �- r -. r - . • ,m • P P 9 Y P post@recgroup.com www.re[rou .com ,,,� •" .4, - -s:. ". A'�1M headquarters in Singapore,REC also has regional hubs in North America,Europe,and Asia-Pacific g P ^h ' S � a HEET NUMBER r✓ r PV-6 NT .. UNsaLA RM OU • 1 . , . ,. , . • , BETTER DESIGNS 0� Mo • 1 r ' 1 ' ' TRUST TILE INDUSTRY'S BEST DESIGN TOOL CONCEALED UNIVERSAL 0 I Start the resign process for every project in our U-Builder on-line design tool, ENDCLAMPS ® 1 ' • , r ■■1 1 ' ' •' • • It's a great'vay to save time and money. • 1 ., ,• BETTER SYSTEMS ONE SYSTEM-MANY APPLICATIONS Quickly w modules flush to the roof on steep pitched roofs.Orient a large variety of modules in Portrait or Landscape.Tilt the system up on flat or low slow roofs. END CAPS INCLUDED Componerns available in mill,clear,and dark finishes to optimize your design financials WITH EVERY ENDCLAMP c and aesthetics. BETTER RESULTS MAXIMIZE PROFITABILITY ON EVERY JOB Trust Unirac to help you minimize both system and labor costs from the time the job is CONCEALED quoted to he time your teams get off the roof.faster installs.Less waste.More Profits. UNIVERSAL SELF UNIVERSAL CLAMPS iFUNIRAC BETTER SUPPORT STANDING MIDCLAMPS WORK WITH THE INDUSTRIES MOST EXPERIENCED TEAM Professional support for professional installers and designers.You have access to25 _ YEAR our techncal support and training groups.Whatever your support needs,we've got / ^, �t�R you covepd.Visit Unirac.com/solarmount for more information. " { OPTIONAL FRONT TRIM FULL-SYSTEM ..� U-BUILDER ONLINE DESIGN WRRNANTY • TOOL SAVES TIME&MONEY • • 1 o BONDING c Visit design.unirac.com • UL2703SYSTEMNMECHANICAL LOADING(TRECLASSIFICATION � r ■ • • • UNIRAC CUSTOMER SERVICE MEANS THE HIGHEST LEVEL OF PRODUCT SUPPORT • • ,.. t--_i � � ■ UIMATCHED CERTIFIED ENGINEERING BANKABLE DESIGN PERMIT � � ' • � � EXCELLENCE WARRANTY TOOLS DOCUMENTATION EIPERIENCE QUALITY � 1 � TECHNCAL SUPPORT CERTIFIED QUALITY PROVIDER BANKABLE WARRANTY Unirac stechnical support team is dedicated to answering Unirac is tile only PV mounting vendor with ISO Don't leave your project to chance,Unirac has the questions&addressing issues in real time.An online certifications for 9001:2008,14001:2004 and OHSAS financial strengthto back OUT products and reduce your risk. library if documents including engineering reports, 18001:2007,which meanswedeliverthe highest standards Havepeace of mind knowingyou are providing products of S' CHOICE FOR. RESIDENTIAL RACKING stampei letters and technical data sheets greatly forfit,form,and function.These certifications demonstrate exceptional quality.SOLARMOUNTis covered bya25yeai THEPROFESSIONAL simpitas your permitting and project planning process. our excellence and commitmemto first class business practices. limited product warranty and a5 year limited finish warranty- BEST INSTALlATIONEXPERIENCE•CURBAPPEAI•COMPLETESOLUTION•UNIRACSUPPORT ENHANCE YOUR REPUTATION WITH QUALITY RACKING SOLUTIONS BACKED BY ENGINEERING EXCELLENCE AND A SUPERIOR SUPPLY CHAIN FOR QUESTIONS 0R CUSTOMER SERVICE VISIT UNIRAC.COM 0R CALL (505) 248-2102 , FOR QUESTIONS OR CUSTOMER SERVICE VISIT UNIRAC.COM OR CALL (505) 248 2702 4 I Ll '. r Unirac State Letter-NY "I"'��'777_ Tectonic WO#:12557.24 HARVESTC':-��:. . ,. .. iectonic ' 7ecto i� August 12,2024 n HARVEST POWER LLC SUNRISE so=a=,oa.......o,.,:=,v . ..+<+i:..soio*:ns s.crr•o�.,ss.rt ��S ��`� R/�l 1 TERRACEHNY HIGHWAY �4F>EC �s L:(801)989-3585 August 12, 2024 www.harvest owernet Metal Roof: Standing Seam Attachments, PM-9OOOs, and PM Adjust Slotted � ° _; i Tile Roof: Solar hooks, Flashkit Tile Replacement(TR) Unirac Attn: Engineering Services Department The U-Builder Tool should be used under the responsible charge of a registered c 1411 Broadway Boulevard NE professional engineer required by the authority having jurisdiction. The design tool c-A r_ c Albuquerque, NM 87102-1545 and Unirac do not evaluate the existing roof structure, or the PV panels themselves. p`,� �2g$ 7 Q� TEL: (505)242-6411 See the construction and installation drawings and manuals for additional Of: y 0 information provided by Unirac. NNE\%I RE: ENGINEERING CERTIFICATION LETTER FOR THE UNIRAC SOLARMOUNT (SM) ROOF PV PANEL SUPPORT SYSTEM Sincerely, ��DF NElvy VERSION STATE: NEW YORK Tectonic Q A. G DESCRIPTION DATE REV. TECTONIC WORK ORDER#:12557.25 o�`o �qt O9� aLDG.PERMIT of osizozs o * z � The Unirac SOLARMOUNT (SM) Photovoltaic Panel Support System is a proprietary I — W UJ framed photovoltaic panel support system that is installed on a roof. Tectonic N c Engineering Consultants, Geologists & Land Surveyors, D.P.C. (Tectonic) has reviewed the SM design methodology along with the U-Builder tool; a Unirac online °A ��1249 design tool. The review included the following SM products, SM Light, Heavy Duty, s10N 08/12/2024 and Standard rail with both the standard and pro hardware. Antonio A. Gualtieri, P.E. Tectonic has determined that the design is a rational approach and follows the Executive Vice President structural requirements of the following reference documents: Codes/Standards: PROJECT NAME • 2020 Building Code of New York State. W • 2018 International Building Code by International Code Council. U • ASCE/SEI 7-16 Minimum Design Loads for Buildings and Other Structures, by Z American Society of Civil Engineers with provisions from SEAOC PV-2-2017. W U) o ❑ • 2020 Aluminum Design Manual, by Aluminum Association. _ J 07 MLO O 0 This letter certifies that the structural analysis of the racking members,connections, z rn o and components directly related to Unirac's system are in compliance with the J o above codes. The design methodology is acceptable under components and Z ,1- � 00 cladding loads associated with the building's roof structure when the system is Z) z o j.: U_ installed in accordance with manufacturer specifications. If the loading criteria does not meet Unirac's specifications, owner shall contact Unirac for a site-specific W D o :1 z certification. Z o 0 0 F' OLc0o � 0 r Attachments approved for the SM system to the structure include the following CL U _ and is installed per Unirac's U-Builder report and installation guides: ❑ 0- > U Q Q ■ Shingle Roof: L-Foot Flashkit Pro, Standoffs, Flashloc Comp, Flash Loc Duo, Q and Flash Kit Pro SB SHEET NAME Project Contact Info Project Contact Info SPEC SHEET 1279 Route 300 1 Newburgh,NY 12550 1279 Roue 300 1 Newburgh,NY 12550 845.567.6656 Tel 1 845.567.8703 Fax 845.567.E656 Tel 1 845 567.8703 Fax SHEET SIZE tectonicergineering.com page 2 of 2 ANSI B tectonicengineering.com Equal Opportunity Employer Equal Optortunity Employer 11" X 17" SHEET NUMBER PV-8