Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
51679-Z
�oAtof Sol/TyO`O Town of Southold * P.O. Box 1179 53095 Main Rd Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 46219 Date: 06/04/2025 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 3825 Stars Rd East Marion, NY 11939 Sec/Block/Lot: 22.-2-26 Conforms substantially to the Application for Building Permit heretofore,filed in this office dated: 01/13/2025 Pursuant to which Building Permit No. 51679 and dated: 02/25/2025 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: Roof-mounted solar panels to existing single-family dwelling as applied for. The certificate is issued to: Samantha Grassle , Luis Palacios Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: 51679 4/29/2025 PLUMBERS CERTIFICATION: uth ed Signature *0sou, TOWN OF SOUTHOLD BUILDING DEPARTMENT • TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 51679 Date: 02/25/2025 Permission is hereby granted to: Samantha Grassle 110 4th Ave Apt 6D Brooklyn, NY 11217 To: install roof-mounted solar panels to existing single-family dwelling as applied for. Premises Located at: 3825 Stars Rd, East Marion, NY 11939 SCTM#22.-2-26 Pursuant to application dated 01/13/2025 and approved by the Building Inspector. To expire on 02/25/2027. Contractors: Required Inspections: Fees• SOLAR PANELS $100.00 ELECTRIC -Residential $125.00 CO-RESIDENTIAL $100.00 Total $325.00 W Building Inspector M pF SOU�yol h O Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 G • Q Southold,NY 11971-0959 �y�4UNVI BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Luis D Palacios Address: 3825 Stars Rd City: East Marion St: NY Zip: 11939 Building Permit#: 51679 Section: 22 Block: 2 Lot: 26 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: GreenLogic License No: 43858ME SITE DETAILS Office Use Only Indoor rv—, Basement �, Service Solar W Outdoor Wo 1 st Floor Pool r Spa r Renovation 1- 2nd Floor Hot Tub r' Generator (- Survey 1-• Roof rV Garage Battery Storage r— INVENTORY Service 1 ph rV-` Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph r Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel 200A A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures �—j Other Equipment: 200A 56Circuit Panel / 52 Used, 9.66kW Roof Mounted PV Solar Energy System w/ (21)REC460 AA PureRX Modules, AC Combiner(3)220Breakers(1)215Monitor, AC Disco, Notes: Lineside Tapped Service Upgrade & Solar Inspector Signature: X Date: April 29, 2025 Sean Devlin Electrical Inspector sean.devlin cD—town.southold.nv.us 3825StarsSolar&Service 0F SoUlyO� 5 6-7 � `/ —`� T.Ir y � TOWN O SOUTHOLD BUILDI� DEP G courm, 631-765-1802 INSPECTION [ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND. [ ] INSULATION/CAULKING ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE.RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE-C/O [ ] RENTAL REMARKS: aje DATE INSPECTOR OF SOUlyo6 # # TOWN OF SOUTHOLD BUILDING DEPT. cou 631-765-1802 [NSPECTION [ ] FOUNDATION 1 ST/ REBAR _ [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ NSULATION/CAAUULKING ] FRAMING /STRAPPING [ ] FINAL ] -FIREPLACE & CHIMNEY.- [: ] FIRE SAFETY-INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] 'FIRE RESISTANT.PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: j DATE INSPECTOR TV � R mat ON ,; ��Z..- i ye - _ gmi Ik�E — , • .' O� I 11 -�dN� IIA i mill _ 1 --� inter 1 ' LIN -As�Ali Lie - A QIiAI ..4u1 I rk lyvll 1 i s4i ti �'_- jI;r)nj•al II ,ill . sill ll'� D A M E S J. S T 0 U T A R C H I T E C T & Assoc . 2 GT REG L ANE E AST N ORTHPORT N. Y. 831 - 858 9388 Post Install Letter April 22, 2025 RE: Palacious Residence 3825 Stars Road East Marion, NY 11939 To Whom it may concern: This letter is to confirm that as of this date April 22,2025, I,James J Stout, NYS license 021633 have visually inspected the placement and installation of the roof top solar panels at the above listed address. The solar panels have been installed as per manufacturers' guidelines and specifications. The racking system design and installation complies with all applicable codes. The installation was done as per the approved Building Department plans. The analysis of the documents supplied by the client relies on sound engineering judgment and relevant experience. However, regardless of the professional's qualifications or thoroughness of the investigation, preexisting conditions cannot always be anticipated beyond the scope of direct observation. No additional guarantees, whether expressed or implied, are provided regarding the professionals' recommendations outlined in this letter. This certification letter must be presented to the municipality within 120 days of the issuance date to ensure compliance with safety procedures and continuity of service. Thank you for your cooperation in this matter. James J. Stout Klk�4,F-D ARC a MELD INSPECTION REPORT DATE COMM7NTS ::�T FOUNDATION (IST) ------ -------- — zj FOUNDATION (2ND) z O ROUGH FRAMING & PLUMBING ------- --- _ .--- Q a , - - --- r INSULATION PER N. Y. ----- --- rn STATE ENERGY CODE - ----�_-.— - -_ ----- --------- Q, av =--- FINAL ADDITIONAL COMMENTS qrD Ins—V Ff cd -------------- --�- `f__!,5�� -- - I nsla t I e-6 cl Z9 9. x l'� o� o2- TOWN OF SOUTHOLD BUII:DING DEPARTMENT Town Ha11 Annex 54375 Main Road P. O.:Box 1179 Southold IVY 11971J-095.9 Q` • Telephone 631 765-1802 Fax 6'1 76:5=9502 htt s://wwwaoutholdtownn : v . y c P.: ( : ):. ) ego Dar..Sec) • =APPLICATION'-FOR:BUILDING :P'ERM:IT: ' . :. For Office Use Only JAN13 ' 0 PERMIT NO,.: � . Building Inspector. peparfinent guild 9 7own of So utho Applications and forms must tie filled out in them entirety Incomplete applications will-not' e.accepted.. Where the Applicant is not the owner,an : :` Owner's AtithdOiiiticiri form(Page 2)shall be completed Date: H�P, � . ... . . OWNERS)OF PROPERTY Name :Luis Palacios.: scTM:# 1000722-2-26: Projeirt address 3825'Stars Road,_East_Marion;;._NY___. . .. ....._._.....:.._.. 'Phone#.425-614 6781 . Email:IuisdanielTOnmail com -Mailing Address: CONTACT.PERSON ..... .. .... ....... __.. _.. . Name:Barbara - GreenLogic:_LLC�'� nnaili►,g Address:-97.:North Sea Road; Southampton NY„ 11:968 ..Phone#:.... ...... ..... : . .::. EmaiL•, _..:. .. :. :. t. .com _ _ Barbara@Greenlogie _ 631-7711-5152 x117 DESIGN:PROFESSIONAL INFORMATION ; Name'. f . . ._ . J_< .... Marling Address::. PlIft Name: :. GreenLogic4LLC_.__., Mailing Address:97 North Sea Road,,Southamoton NY 11968 Phone#g631-771:-5152 _ Email:AM@GreenlogiC Com DESCRIPTION OF PROPOSED CONSTRUCTION ❑:New Structure. ❑Addition _ BAlteration ORepair El Demolition. Estimated Cost of Project: DOther Solar:Panels $:.30,000': . Will the lot be re:-graded?.❑Yes BNo Will excess fill be removed from premises? ❑Yes B No ;�PROP.ERTY INFORMATION:; Existing-use of property:' :Intended use of property: Zone or use district in.which premises is situated: Are there any covenants.and restrictions with respect-to ._ �. _. _....W � this property?:❑ [�Yes No IF YESS,:PROVIDE A COPY..: r 1' J � ®"Check Box After Read Ing The owner/contractor/design`professional is responstble.for all drainage anal storm water Issues as provided by; .. fChapter 236 of the Town Code APPLICATION IS HEREBY MADE to the:Building Department fortiie issuance of a BulldingPermit pursuant to the.Building Zane Ordinance of,.the Town'Sof Southold,Suffolk,rCounty,,New York and other applicable Laws;Ordinances or Regulations,for the construction of buildings, additions,alterations odor removal ordemoliUonas herein described:The applicant agreestotoinply with all applicable laws,ordinances,buildingcode; housing code and regulations and,to admd,authorized inspectors on premises and in buitding(s)for necessary inspeetions.False statements made herein are . punishable aka Class A°misdemeanor purs0rvt to.Se,ction:210A5 of the New_York State Penal Law.. ii E ,1Jr att%% C3d..�i;•,J 7 , GreenLogic LLG= Application Submitted By(print name): BAuthorized Agent . .3Owner.. Signature of Applicant Date STATE OF NEW YORK) SS: COUNTY OF Suffolk Nesim Albukrek _ being duly sworn,deposes and says that(s)he:is the,applicant-;- -: (Name:ofindividualsigning:contract):above named, (S)he is the. Contractor (Contractor,Agent,Corporate Officer,etc:) of said owner or owners,and is duly authorized to perform or.have performed the:said work Viand to make and file:this application;that all statements contained in this application are true to the best of his/her knowledge and-belief;and:.: that the work will be performed in the manner set forth in:the application file therewith.. Sworn before me this _day-of T 20,25 Notary Public. BARBARA A CASCIOTTA . PROPERTY OWNER AUTHORIZATION Notwy.P.ublic-State of New Yo►:: No.OtCA413AM licant.is not the owner Gualifled.InSuffolkCoull*., (Where the a p p ): Commisslon Kxplres May 11,20P, L y I S .14. i S .. residing.at. ZA5 i .:: fi 160, D') do.hereby au .� GreenLogic LLC: t2 7 .. thorize to.apply on"'. my behalf to the Town of Southold Building Department for approval as described:he rein. 1 : Owner's Signature Date; C C G)f KLEEFIELD A:GEORGES - . Print Owner's Name Notary':Public-State of New York- . .... N0.01GE6234683 .. Qualified in Kings County :My Commission Expires May 21,2027 -) �QSt1F kc� BUILDING DEPARTMENT- Electrical Inspector 0�0 Gym TOWN OF SOUTHOLD Town Hall Annex - 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 rogerr(cD-southoldtownny -gov — seand(absoutholdtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 1/7/2025 Company Name: GreenLogic LLC Name: Robert Skypala License No.: 43858-ME. email: Barbara@Greenlogic.com Phone No: 631-771-5152 ❑✓ I request an email copy of Certificate of Compliance Address.: . 97 North Sea Road Southampton, NY 11968 JOB SITE INFORMATION (All Information Required) Name: Luis Palacios Address: 3825 Stars Road, East Marion, NY Cross Street: Phone No.: 425-614-6781 Bldg.Permit#: email: iuisdaniel@gmail.com Tax Map District: 1000 Section: 22 Block: 2 Lot: 26 BRIEF DESCRIPTION OF WORK (Please Print Clearly) Roof mounted solar electric system **(21) REC460AA PURE-RX panels Ft (21) Enphase IQ78x micro inverters (1) Enphase IQ Gateway ENV2-IQ-AMI System Size: 9.660KW Check All That Apply: Is job ready for inspection?: DYES 0NO ❑Rough In OFinal Do you need a Temp Certificate?: ❑✓ YES [:]NO Issued On Temp Information: (All information required) Service Size ❑1 Ph ❑3 Ph Size: A #Meters Old Meter# ❑New Service ❑ Service Reconnect ❑ Underground ❑Overhead # Underground Laterals 01 02 ❑H Frame ❑Pole Work done on Service? ❑Y ❑N Additional Information: PAYMENT DUE WITH APPLICATION bald wl Electrical Inspection Inspection Form 2020.xfsx ,7 .y�,`�q,'•i MAR 3 1 2025 �.. • gUflpl,� BUILDING DEPARTMENT- Electrical Inspector �O`O CpGy TOWN OF SOUTHOLD t `v� dsf r �a=���a�.'.�s to dyee(� N Town Hall Annex- 54375 Main Road - PO Bo 1`79` �+ Southold, New York 11971-0959 py�lap� Telephone (631) 765-1802 - FAX (631) 765-9502 rogerresoutholdtownny gov -- seandO-southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 1/7/2025 Company Name: GreenLogic LLC Name: Robert Skypala License No.: 43858-ME email: BarbaraCGreenlogic.com Phone No: 631-771-5152 ❑✓ I request an email copy of Certificate of Compliance Address.: . 97 North Sea Road Southampton, NY 11968 JOB SITE INFORMATION (All Information Required) Name: Luis Palacios Address: 3825 Stars Road, East Marion, NY Cross Street: Phone No.: 425-614-6781 Bldg.Permit#: 5\�-Jq email: luisdaniel@gmail.com Tax Map District: 1000 Section: 22 Block: 2 Lot: 26 BRIEF DESCRIPTION OF WORK (Please Print Clearly) Roof mounted solar electric system **(21) REC460AA PURE-RX panels a (21) Enphase IQ78x micro inverters (1) Enphase IQ Gateway ENV2-IQ-AMI System Size: 9.660KW *� e'M—a@am,P?Serr Check All That Apply: Is job ready for inspection?: DYES ✓❑NO ❑Rough In ZFinal Do you need a Temp Certificate?: OYES ❑NO Issued On Temp Information: (All information required) Service Size ❑1 Ph ❑3 Ph Size: 200 A # Meters 1 Old Meter# ❑New Service ❑ Service Reconnect ❑ Underground ❑Overhead # Underground Laterals 01 ❑2 ❑H Frame ❑Pole Work done on Service? ❑Y ❑N Additional Information: PAYMENT DUE WITH APPLICATION LJO Electrical Inspection Form 2020.xlsx MAR 3 1 2025 BUILDING DEPARTMENT- Electrical Inspector V ��O Gym TOWN OF SOUTHOLD o Town Hall Annex - 54375 Main Road - PO Box-1.179 Southold, New York 11971-0959 oy�o� ap� Telephone (631) 765-1802 - FAX (631) 765-9502 rogerr -southoldtownny aov - seandesoutholdtownny._ ov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 1/7/2025 Company Name: GreenLogic LLC Name: Robert Skypala License No.: 43858-ME email: Barbara@Greenlogic.com Phone No: 631-771-5152 ❑✓ I request an email copy of Certificate of Compliance Address.: . 97 North Sea Road Southampton, NY 11968 JOB SITE INFORMATION (All Information Required) Name: Luis Palacios Address: 3825 Stars Road, East Marion, NY Cross Street: Phone No.: 425-614-6781 Bldg.Permit#: email: luisdaniel@gmail.com Tax Map District: 1000 Section: 22 Block: 2 Lot: 26 BRIEF DESCRIPTION OF WORK (Please Print Clearly) Roof mounted solar electric system **(21) REC460AA PURE-RX panels Et (21) Enphase IQ78x micro inverters (1) Enphase IQ Gateway ENV2-IQ-AMI System Size: 9.660KW Upgrade to 200amp service Check All That Apply: Is job ready for inspection?: ❑YES ENO ❑Rough In ZFinal Do you need a Temp Certificate?: ZYES ❑NO Issued On Temp Information: (All information required) Service Size ❑1 Ph ❑3 Ph Size: 200 A # Meters 1 Old Meter# ❑New Service ❑ Service Reconnect [-] underground ❑Overhead # Underground Laterals 01 02 ❑H Frame❑Pole Work done on Service? ❑Y ❑N Additional Information: PAYMENT DUE WITH APPLICATION yl� la� Electrical Inspection Form 2020.xlsx PERMIT# Address: Switches Outlets GFI's Surface Sconces H H's UC Lts Fridge HW POOL Fans Mini Fr. WAD Panel Pump . Exhaust Oven Sump Heater Trnsfmr Smokes DW Generator Salt Gen. Carbon Micro GrbDis Water Bond Lights Heat Pucks ERV HOT TUB/SPA Inst Hot DeHum Transfer Disc Combo Cooktop Minisplit Blower AC AH Hood Blower \ Service Amps Have JV Used Sub Amps Have Used Comments GREENLOGIC® ENERGY March 27 2025 k 4 Town of Southold Building Department Town Hall 53095 Route 25 Southold, NY 11971 Project Info: Luis Palacios 3825 Stars Road East Marion, NY 1000-22-2-26 Permit: 51679 Dear Building Inspector: Attached please find an amendment to our electrical inspection. We will be upgrading the electrical service to 200 amp. I've also enclosed a check for$100 for the additional work. Please let us know if you need anything else in connection with this application. Yours truly, J3a 46a 4a.eao ckWa Barbara Casciotta Accouht.MaJ nager Barbara@Greenlogic.com 631-771-5152 ext. 117 GREENLOGIC LLC •www.GreenLogic.com Tel: 631.771.5152 Fax: 631.771.5156 SOUTHAMPTON ROSLYN HEIGHTS 97 North Sea Rd.,Suite 3 200 S. Service Rd.,#104C Southampton, NY 11968 Rosyln Heights, NY 11577 GIREENLOGIC° ENERGY May 15, 2025 7, The Town of Southold Building Department MA`( 2 g 2025 54375 Route 25 t , n P.O. Box 1179 Southold, NY 11971 Project Info: Building Permit No. 51679 Luis Palacios 3825 Stars Road East Marion, NY To the Building Inspector: Enclosed please find the Engineer's Certification Letter for the above referenced address. Can you please close the building permit and send the Certificate of Occupancy after inspection? Please let me know if you have any questions about the installation. Sincerely, 33a 4bim e4"CiOI& Barbara Casciotta Account Manager Barbara@Greenlogic.com 631-771-5152 Ext. 117 GREENLOGIC LLC•www.GreenLogic.com Tel: 631.771.5152 Fax: 631.771.5156 SOUTHAMPTON ROSLYN HEIGHTS 97 North Sea Rd.,Suite 3 200 S.Service Rd.,#104C Southampton, NY 11968 Rosyln Heights, NY 11577 FlCAMONS HEREON SIGNIFY TWIT TNS PLAT OF PROPEW 19 A TRUE AND CORRECT•REIMENfAVON OF A RECENT SURMfY WWE UNDUE MY DOMON IN ACCORDANCE WITH THE DUSTING CODE OF PRACTICE R LAND.SURVEYORS BY THE NEW YORK STATE ASSOCNIIIDN OF PROFESSIONAL LAND SURVEYORS.SAID CERIIFICA710NS SWILL RUN ONLY TO THE PERSON WNOM 1HE SURVEY WAS PREPARED AND ON THEIR BEHALF TO TEE TIRE COMPANY.WA M MAL AOENLY AND LENDING INSIMUTIOFI LSTED HERON.THS CERTM710H S ONLY FOR THE LANDS DESCRIBED NLOMON.ITS NOT A CERIMTKLN OF TTILF ZONDKI, OR FREEDOM FROM ENCUMBRANCES.COMFrAYIDNS ARE NOT NOT 7RANSFFRABLE TO ADD=WL OR SUBSEQUENT OWNERS. I a p TAX LOT 39.1 N78036'30"E 105.00' T I FE MON. LFE 6'N STOCKADE FENCE 2.8`N TAX FND. ❑ O ❑ LOT FE CHAIN LINK.r FENCE FE FE 40 G0.3 E/S BLDG. 0.2'S 0.4'S 3.0'S FE MASONRY (V O.EiW GARAGE i � � m BLDG. fZi�U STONE ' 00. O V 4.2'E ' 22.3' CN O - DRIVEWAY O 0 N 3 z p INGRO[!ND POOL 16'x 32, 91 Hwy �p CONCRETE 03 aO p . z a3 u 3.I > 0 AWNING OVER 5 CELLAR ENTRANCE TAX LOT STEPPING STONES 41 GATE ' MAS. PIER 28.2' W � x via STEPPING STONES M MASONRY PIER M STOOP N z c O a N •. r,l M J5 0 (� '~ 2NDSTORY DECK W 2 STORY O FE 33'8- C+l 0.2'E FRAME 28.I' 6.5' PLAYHOUSE BDG.~ . 0 N FE 3N. TAX 0.574 4'E MON. LOT 0FB 0.4'N FND. (� FE 4$.1 024J CHAIN LINK FENCE MOH, FND. S 78036'30"W 107.281 I TAX , LOT I 25 THE OFFSETS OR Dim SHOWN FROM THE IYPROMEMIM 70 TW PROPERTY ONES ARE FOR A SPEAIFIC PURPOSE AND IRE,AND THEREFORE ARE NOT MENDED TO BE USED AS A GUIDE IN YK ERECTION OF FENCES,W418 POOLS,PATIOS,BULDINGS.ADM=M BURDINGS OR ANY OMER IMPROMf]BEF M SUL1SWACE AND DMORNMENTAL CONDMONS NOT SHOWN.PROPERTY CORNER MARKERS WERE NOT SET AS A PART OF THIS SURVEY. FAMENIS AND OR RIGHISOF-WAY OF RECORD,IF ANY.NOT MOMM. PJM LAND SURVEYING, PL LC UNAUTHORIZED ALTERATION OR 132 CLYDE STREET/SUITE 16 ADDITION TO,THIS SURVEY IS A WEST SAYVILLE,NY 11796 VIOLATION OF.SECTION 7209 OF PHONE 631-563-0400 NEW YORK STATE'EDUCATION LAW. FAX 631-563-5808 PJMSURVEYING AOL.COM LOT:--- REVISIONS MAP OF:DESCRIBED PROPERTY FILED:---- NO:---- COUNTY:SUFFOLK SITUATE:EAST MARION TOWN OF SOUTHOLD COPIES OF THIS SURVEY MAP NOT CERTIFIED TO: TITLE NO.:7404-016999 BEARING THE LAND SURVEYOR'S EMBOSSED SEAL AND SIGNATURE SAMANTHA GRASSLE&LUIS DANIEL PALACIOS SHALL NOT BE CONSIDERED A TRUE FIDELITY NATIONAL TITLE INSURANCE COMPANY AND VALID COPY MORTGAGE ELECTRONIC REGISTRATION SYSTEMS, INC., PROJECT NO.:2023.-277 AS NOMINEE FOR ROCKET MORTGAGE LLC,ISAOA/ATIMA DATE: 10/05/ 02 DRAWN:CM CHECKED BY:PM SCALE: 1"=20' DISTRICT: 1000 SECTION:22" BLOCK:02 LOT(S)226 CERTIFICATIONS HEREON SIGNIFY THAT TIES PLAT OF PROPERTY 0 A TRUE AND CORRECT REPRESENTATION OF A RECENT SURVEY MADE UNDER MY DIRECTION IN ACCORDANCE WITH THE DUSTING CODE OF PRACDCE R L(q SURVEYORS BY THE NEW YORK STATE ASSOCIATION OF PROFESSIONAL LAND SUMINORS.SAID CER[FICATIONS SHALL RUN ONLY TO THE PERSON WHOM THE SURVEY WAS PREPARED AND ON THEIR 80"TO THE TITLE COMPANY.W4ENMERTAL AGENCY AND LENDING INSTITUTION LISTED HERON,THIS CERTM7ION S ONLY FOR THE LANDS DESCRIBED HEREON.ITS NOT A CERRFKATION OF TITLE, ZONING, OR FREEDOM FROM ENCUMBRANCES.CERTIFICATIONS ARE NOT NOT TRANSFERABLE TO ADDITIONAL OR SUBSEQUENT OWNERS. 1 , O C TAX LOT 39.1 N78036'30"E 105.00' I e • I FE MON. E STOCKADE FENCE 2TAX FIND. LF 6'N C 0 LOT FE CHAIN LINK• FENCE FE FE 40 O.L.NIS �' 0.2'S� 0.4'S 0.31E BLDG. 3.0'S FE MASONRY TN O.L.E/W GARAGE U BLDG. STONE I 00 0 4.2'E 22.3' C> DRIVEWAY o O Q a p INGROUND POOL � 16'x 32' 2� ' r F,� • CONCRETE y �O > 2 a 3 AWNING OVER CELLAR ENTRANCE TAX LOT .a STEPPING STONES 4I GATE MAS. PIER > n 28.21STEPPING STONES a W al z ¢O �, y g �� �h MASONRY STOOP PIER M N a N M 0 "~ STO ^'� ¢ DECK W 2 STQRY 33.8'. C p E IRA E 28.P o. fYl \D 6.5'a PLAYH USE BOG. v1 ¢ 0 N FE YN 4 E TAX 0.5N FE MON. r~ LOT 0.51E 0.4'N FND. \ IE 4 CHA LINK F � MON. S7 6'30"W "t 107.28' I TAX .LOT I 25 THE OFiSM 6R DIMENSIONS SHOWN FROM THE IMPROV09MM TO THE PROPUM UNES ARE FOR A SPES,TFIO PURPOSE AND USE,AND THEREFORE ARE NOT INTENDED TO BE USED.AS A GUIDE IN THE ERECTION OF FENCES.WALLS,POOLS, PATIOS, BUILDINGS.ADDITIONS TO BUILDINGS OR ANY OTHER IMPROPiMENM SUBStRtF'ACE AND ENVKNNMERTAL CONDITIONS NOT SHOWN.PROPERTY CORNER MARKERS WERE NOT SET AS A PART OF THIS SURVEY.EASEMENTS AND OR PoGHIS-OF-WAY OF RECORD,IF ANY,NOT SRN. PJM LAND SURVEYING, PLLC UNAUTHORIZED ALTERATION OR 132 CLYDE STREET/SUITE 16 ADDITION TO THIS SURVEY IS A VIOLATION OF SECTION WEST SAYVILLE,NY 11 EDU .796 OF PHONE 631-563-0400 NEW YORK STATE EDUCAATIOTIO N LAW. FAX 631-563-58p8 PJMSURVEYIN AOL.COM LOT:--- REVISIONS MAP OF:DESCRIBED PROPERTY FILED:---- NO:---- COUNTY: SUFFOLK SITUATE:EAST MARION TOWN OF SOUTIIOLD COPIES OF THIS SURVEY MAP NOT CERTIFIED TO: TITLE NO.: 7404-016999 BEARING THE LAND SURVEYOR'S EMBOSSED SEAL AND SIGNATURE SAMANTHA GRASSLE&LUIS DANIEL PALACIOS SHALL NOT BE CONSIDERED A TRUE FIDELITY NATIONAL TITLE INSURANCE COMPANY AND VAUD COPY MORTGAGE ELECTRONIC REGISTRATION SYSTEMS, INC., PROJECT NO.:2023-277 AS NOMINEE FOR ROCKET MORTGAGE LLC,ISAOA/ATIMA DATE: 10/05/202 DRAWN:CM CHECKED BY:PM SCALE: V=20' DISTRICT: 1000 SECTION:22 BLOCK:02 LOT(S):26 r -- -- - NEW EQUIPMENT ---� ---- -- -- -- -- -- -- --- 120/240, 1 PH, 3W PV-SA-1 A AC-COMBINER PANEL (TYPICAL SYSTEM SCHEMATIC, i FINAL INSTALLATION MAY VARY, • • • � � AC-CMB-1 REQUIRES LOCAL AHJ AND UTILITY APPROVAL) i N • • • 21 (EXTERNAL NEMA-3R) 200A KWH 1ODA B PV-SA-2 ,q I MAIN �--� • . • M M A B N i • • • BKR-1 I TYPICAL PV MODULE WITH I I BKR-2 INTEGRAL DC/AC INVERTER I I I I TYP. PV ARRAY I I I 200A MAIN n II I BKR N BKR-M I A B N PV-SA-N ' I + : : N : 2 N TYPICAL PV MODULE WITH INTEGRAL DC/AC INVERTER III 4EGC PM-1 I III C t�' Lt U E �` III I C N i III ? � EGC I I I I I MAIN C/T APR 15 2025 AC DISTRIBUTION I GEC III EGC 1 I I #4 CU 1--------#6 CUB------ r2uIlf ing c�� ' - IRREVERSIBLE BOND,-TYP. REVISIONS / Palacios, Luis 3825 Stars Road GREENLOGIC® L,...'. r ENERGY East Marion NY 11 939 2.) AS-BUILT CONFIGURATION el'0Zt5s�yoe ELIMINATING THE COST OF ENERGY 1.) INITIAL SUBMITTAL WITH PV APPLICATION Page 1 of 4 Drawing No: PLCS-3LD2 Revision: 2 V Revised: 4/10/2025 Ik c SYSTEM SUMMARY TOTAL KW RATING: (AC POWER) 8.064 kW TOTAL KW RATING: (DC POWER) 9.660 kW CITY. COMPONENT SPECIFICATION REC BRAND, MODEL: REC460AA PURE-RX 21 PV MODULE: (REC460AA) 460 W DC(NOMINAL), EACH ENPHASE BRAND, MODEL: IQ8X-M-US 21 PV INVERTER: (INTEGRAL TO MODULE) 384 VA, 1.58 A, 240V AC, EACH rn E VU E APR 1 5 2025 _._. REVISIONS Palacios, Luis GREENLOGIC° 3825 Stars Road ENERGY East Marion, NY 11939 2.) AS-BUILT CONFIGURATION ELIMINATING THE COST OF ENERGY 1.) INITIAL SUBMITTAL WITH PV APPLICATION Page 2 of 4 Drawing No: PLCS-3LD2 Revision: 2 Revised: 4/10/2025 r EQUIPMENT&COMPONENT SCHEDULE TAG DESCRIPTION SPECIFICATION REC BRAND MODULES, MODEL:ALPHA REC460AA PURE—RX, 460W, WITH PV—SA-1 PHOTOVOLTAIC SUB—ARRAY ENPHASE IQ8X-80—M—US INVERTER, 1—CIRCUIT OF 4—INVERTERS REC BRAND MODULES, MODEL:ALPHA REC460AA PURE—RX, 460W, WITH PV—SA-2 PHOTOVOLTAIC SUB—ARRAY ENPHASE IQ8X-80—M—US INVERTER, 1—CIRCUIT OF 8—INVERTERS REC BRAND MODULES, MODEL: ALPHA REC460AA PURE—RX, 460W, WITH PV—SA-3 PHOTOVOLTAIC SUB—ARRAY ENPHASE IQ8X-80—M—US INVERTER, 1—CIRCUIT OF 9—INVERTERS PM-1 PV SYSTEM POWER MONITOR ENPHASE BRAND, ENPHASE GATEWAY AC—CMBP AC COMBINER PANEL 250V, 100A, NEMA-1, MAIN BREAKER 100A, 1—PH, 3—WIRE BKR-1...BKR-3 CIRCUIT BREAKER, PV—SA-1...PV—SA-3 MATCH AC COMBINER PANEL BRAND, 2—POLE, 20A BKR—M CIRCUIT BREAKER, PM-1 MATCH AC COMBINER PANEL BRAND, 2—POLE, 15A AC—DSC-1 AC DISCONNECT (LINE TAP), BREAKER 250V, 60A, NEMA-1, CIRCUIT BREAKER; RATING: 60A AC—DSC-2 AC DISCONNECT, EXTERIOR LOCATION 250V, 60A, NEMA-311, CIRCUIT BREAKER, RATING: 60A EC E WE � kf s? I f 751 i .�j REVISIONS Palacios, Buis GREENLOGIC® 382 � a�tf Eo � ENERGY East Marion, NY 11939 2.) AS—BUILT CONFIGURATION ELIMINATING THE COST OF ENERGY 1.) INITIAL SUBMITTAL WITH PV APPLICATION Page 3 of 4 Drawing No: PLCS-3LD2 Revision: 2 Revised: 4/10/2025 ELECTRICAL LOAD SUMMARY,AC CIRCUITS TAG POWER, MAX -VOLTAGE MAX.AC VOLTAGE, NOMINAL RANGE CURRENT PV-SA-1 1,536 WATTS 211-264 VAC 6.32 A AC 240 V,AC PV-SA-2 3,072 WATTS 211-264 VAC 12.64 A AC 240 V,AC PV-SA-3 3,456 WATTS 211-264 VAC 14.22 A AC 240 V,AC PM-1 35 WATTS N/A 0.15 A AC 240 V,AC CONDUCTOR SCHEDULE TAG TYPE CONDUIT AWG. / EGC A THWN-2 3/4" PVC-40 10 / 10 B THWN-2 1" PVC-40 4 / 6 E V E p C THWN-2 3/4" EMT 14 / 14 E 17 .)CONDUCTOR TYPES AND SIZES TO BE ADJUSTED FOR TEMPERATURE, DISTANCE,AND DERATING FACTORS. A P 1 15 2025 1 2 ) ELECTRICAL CONDUITTO BE MINIMUM PVC SCHEDULE 40,ADJUST FOR SITE CONDITIONS. Build! E-0 Depadment 3.) ALL ELECTRICAL MATERIALS AND INSTALLATION METHODS TO COMPLY WITH NEC AND LOCAL CODE REQUIRMENTS. TCZ?dF Okcutet01d 4.) NOTE: EQUIPMENT GROUNDING CONDUCTOR TO BE#6 COPPER, MINIMUM REVISIONS Palacios, Luis GREENLOGIC® 3825 Stars Road ct ENERGY East Marion, NY 11939 2.) AS-BUILT CONFIGURATION ELIMINATING THE COST OF ENERGY 1.) INITIAL SUBMITTAL WITH PV APPLICATION Page 4 of 4 Drawing No: PLCS-3LD2 Revision: 2 Revised: 4/10/2025 J A4MES J. S TOUT A R C H I T E C T Assoc. 2 G R E G L A N E E AST NORTHPORT N. Y. 831 - 8 58 9388 COMPLY WITH ALL CODES OF NEW YORK STATE&TOWN CODES Certification Letter AS REQUIRED AND CONDITIONS OF November 12, 2024 SOUTHOLD TOW BA SOUTHOLD T PLANNING BOARD Re: Palacios Residence SOUTHO TOWN TRUSTEES 3825 Stars Road — NX EC East Marion, NY 11939 S OLD HX CHD To Whom it may concern: I, James J. Stout, registered architect NYS license number 021633 would like to submit the following. I have inspected and analyzed the roof structure at the above listed address and have determined the stricture and the attachment to be adequate to support the new additional load imposed by the proposed solar system and complies with the 140-mph wind design load as per 2020 Residential code of NYS (RCNYS), 2020 Energy conservation construction code of NYS (E('.'CCNYS), and the ASCE 7-16. The existing 2"x 6"@ 16"o.c. roof rafters will provide adequate support. Thank you for your understanding in this matter. Thank you APPAOVED AS NOTED James Stout D • ��� BY.- NOTIFY BUILDING.DEPARTMENff&- 631765.1802 BAM TO 4PM FOR THE FOLLOWING INSPECTIONS: \R' 1. FOUNDATION-TWO REQUIRED d FOR POURED CONCRETE Q �,Q' c'a 2. ROUGH-FRAMING&PLUMBING 3. INSULATION ' * 4. FINAL-CONSTRUCTION MUST ' BE COMPLETE FOR C.O. ?21 ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THECODESOFNEW YORK STATE. NOT RESPONSIBLE FOR OCC U PAN C DESIGN OR CONSTRUCTON ERRORS USE IS UNLAWFUL WITHOUT CERTIFICATE ELECTRICAL OF OCCUPANCY INSPECTION REQUIRED GREENLOGICO ENERGY GreenLogic,LLC Approved Palacios,Luis 3825 Stars Road East Marion,NY 11939 Surface#A: Total System Size:9.660kW Array Size:7.820kW 1 circuit of 9 on a 20A breaker 1 circuit of 8 on a 20A breaker Azimuth:242" Pitch: Monitorinrin g System: EnPhase Pand/Array Specifications: Panel:REC460AA PURE-RX Racking:IronRidge Panel:68.0"X 474' Array:34'1 718"X 11'11" Surface:42'1"X 16'2" Legend- ® 17 REC Alpha Pure-RX 46OW 17 lQ8X Microlnverters ® Iron Ridge XR-100 Racking o 0 48 IronRidge Flash Foot 2 08 2x6"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:IronRidge,REC,EnPhase Added Roof load of PV System:2.32psf Engineer/Architect Seal: 1. r ' ^ Drawn By:MA Drawing#1 of 8 Date:1 1/812 0 24 REV:A Drawing Scale:3/16"=1.0' GREENLOGICO ENERGY GreenLogic,LLC Approved Palacios,Luis 3825 Stars Road East Marion,NY 11939 Surface#A: Total System Size:9.660kW Array Size:7.820kW 1 circuit of 9 on a 20A breaker 1 circuit of 8 on a 20A breaker Azimuth:242" Pitch: Monitorinrin g System: EnPhase Panel/Array Specifications: Panel:REC460AA PURE-RX Racking:IronRidge Panel:68.0"X 47.4" Array:34'1 7/8"X 11'11" Surface: z, Legend- ® 17 REC Alpha Pure-RX460W 17 IQ8X Microlnverters ® Iron Ridge XR-100 Racking o • 48 IronRidge Flash Foot 2 8 8 2x6"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:IronRidge,REC,EnPhase Added Roof load of PV System:2.32psf Engineer/Architect Seal: z r, ] 5 10I1 Drawn By:MA Drawing#2 of 8 Date:1 1/8120 24 REV:A Drawing Scale:3/16"=1.0' GREENLOGIC" ENERGY GreenLogi'c,LLC Approved Palacios,Luis 3825 Stars Road East Marion,NY 11939 Surface#A: Total System Size:9.660kW Array Size:7.820kW 1 circuit of 9 on a 20A breaker 1 circuit of 8 on a 20A breaker Azimuth:242' Pitch: Monitorinrin g System: EnPhase Panel/Array Specifications: Panel:REC460AA PURE-RX Racking:IronRidge 1 2 Panel:68.0"X 47.4" Array:34'1 7/8"X 11'11" Surface:42'1"X 16'2" ELegend: 17 REC Alpha Pure-RX 460W 1 2 ® 171Q8X Microlnverters ® Iron Ridge XR-100 Racking o 0 48 IronRidge Flash Foot 2 Ed 2x6"Douglas Fir Rafter 16"O.C. 1 2 Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:IronRidge,REC,EnPhase Added Roof load of PV System:2.32psf Engineer/Architect Seal: �10 ac E9 to 2 3'' y0? Drawn By:MA Drawing#3 of 8 Date:11/8/2024 REV:A Drawing Scale:3/16"=1.Y GREENLOGIC° ENERGY GremL,ogic,LLC Approved Palacios,Luis 3825 Stars Road East Marion,NY 11939 Surface#B: Total System Size:9.660kW Array Size:1.840kW 1 circuit of 4 on a 20A breaker Azimuth:62' i Pitch:18° ls� Monitoring System: EnPhase Panel/Array Specifications: Panel:REC460AA PURE-RX Racking:IrorRidge Panel:68.0"X 474' Array:1 T 4 3/8"X 7'11 1/8" Surface:42'1"X 16'2" Legend: ® 4 REC Alpha Pure-RX 46OW 4 IQ8X Microlnverters ® Iron Ridge XR-100 Racking • 14 IrwRidge Flash Foot 2 8 8 W"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4' Materials Used:IronRidge,REC,EnPhase Added Roof load of PV System:2.32psf Engineer/Architect Seal: Z ckf_D C r h y . Drawn By:MA Drawing#4 of 8 Date:11/8/2024 REV:A Drawing Scale:3/16"=IV GREENLOGICO ENERGY GreenLogic,LLC Approved Palacios,Luis 3825 Stars Road East Marion,NY 11939 Surface#B: Total System Size:9.660kW Array Size:1.840kW 1 circuit of on a 20A breaker Azimuth:62" Pitch: _. Monitorinrin g System: EnPhase Panel/Array Specifications: Panel:REC460AA PURE-RX Racking:IronRidge NT Panel:68.0"X 47.4" Array:1 T 4 3/8"X 7'11 1/8" Surface:42'1"X 16'2" Legend: ® 4 REC Alpha Pure-RX46OW 4 IQ8X MicrolnverteFs ® Iron Ridge XR-100 Racking 0 14 IronRidge Flash Foot 2 a a 2x6"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:IronRidge,REC,EnPhase Added Roof load of PV System:2.32psf Engineer/Architect Seal: Q �Q OA r � 1021 Drawn By:MA Drawing#5 of 8 Date:11/8/2024 REV:A Drawing Scale:3/16"=1.1Y GREENLOGIC" ENERGY GreenLogic,LLC Approved Palacios,Luis 3825 Stars Road East Marion,NY 11939 Surface#B: Total System Size:9.660kW Array Size:1.840kW 1 circuit of 4 on a 20A breaker Azimuth:62° Pitch: Monitorinrin g System: EnPhase Panel/Array Specifications: Panel:REC460AA PURE-RX Racking:IronRidge Panel:68.0"X 47.4" Array:1 V 4 3/8"X 7'11 1/8" 3 Surface:471"X 16'2" Legend: ® 4 REC Alpha Pure-RX 46OW 4 IQ8X Microlnverters ® Iran Ridge XR-100 Racking 30 141ronRidge Flash Foot 2 8 8 W"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:IronRidge,REC,EnPhase Added Roof load of PV System:2.32psf Engineer/Architect Seal: tp21$33 y0� Drawn By:MA Drawing#6 of 8 Date:11/8/2024--[REV:A Drawing Scale:3116"=1.0' No Vent Pipes Will Be Covered By The Solar Array G�GREENLOGIC® ENERGY Legend: GreenLogic,LLC Approved Palacios,Luis AR-Access Roof AP-Access pathway,36"minimum width SVO—Setback at ridge 3825 Stars Road per R202 definitions per R324.6.1 as per R324.6.2.1 East Marion,NY 11939 Total System Size:9.660kW 1 circuit of 9 on a 20A breaker 1 circuit of 8 on a 20A breaker 1 circuit of 4 on a 20A breaker Azimuth:62° 17 REC 460W _SL Panels Monitoring System: EnPhase Panel/Array Specifications: Panel:REC460AA PURE-RX Racking:IronRidge Panel:68.0"X 47.4" Surface:42'1"X 36'8" Legend: ® 21 REC Alpha Pure-RX460W 21 IQ8X Microlnverters ® Iron Ridge XR-100 Racking 0 62 IronRidge Flash Foot 2 svo77 2x6"Douglas Fir Rafter 16"O.C. r--------- svo— --- ------- r Notes: Meter I I I Number of Roof Layers:1 Height above Roof Surface:4" I I Materials Used:IronRidge,REC,EnPhase AP AP I , Added Roof load of PV System:2.32psf Engineer/Architect Seal: I � I I I i lV gED C t•-j— 4 REC 46OW o�Panels �q i021 Drawn By:MA Drawing#7 of 8 Date:11/8/2024 REV:A Drawing Scale:3/32"=1.0' GREENLOGICO ENERGY GreenLogic,LLC Approved Palacios,Luis 3825 Stars Road ----—---- _.._ ..--- -----------.. ---- —--- �.__... — —_ ----- -------- - -— - - --- - --� -- --— — __ East Marion,NY 11939 JOB MATERIAL LIST ' l i Total System Size:9.660kW 1 circuit of 9 on a 20A breaker 1 circuit of 8 on a 20A breaker 1 circuit of 4 on a 20A breaker Azimuth:6 1 Material List QtV. Rail Material List �JL_ Monitoring System. a se Panel/Array Specifications: Cast Aluminum Mounting BlockwacuminumFlashing ; 62 ;_»V ( Panel:REC460AA PURE-RX JBl Black Racking:lronRidge 5/16"x0,75"FenderWash_er_ 62 Panel:68.0"X 47.4" 51 1G'x4.75"Hex-Head Lag Screw _62 _ Surface:42 1"X 36'8" Legend. ® 21 RECAIpha Pure-RX 460W -- .__.__..- ______�____ ___ ._. __ ,.____. ._. -_- - _ ._. r __ k _ 21 IQ8XMicminverters �__________._____-____.____ - ___,_ ._. _.__.._ .._. ...______ ,._.____.. __...___.-_.._.___.__.. __..._._.»_____.___ __�.__ _ _•.__ »_,_ __. ._._. _.__� Iron Ridge XR-100 Racking + • 62 IronRidge Flash Foot 2 ..__._ . . _._-._ --i__._ - __-_ --_- -..---- 8 8 W"Douglas Fir Rafter 16"O.C. . i Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:IronRidge,REC,EnPhase Added Roof load of PV System:2.32psf Engineer/Architect Seal: Z �REQ qAC C9C� S 3 �Q O� r9 1021 Drawn By:MA Drawing#8 of 8 Date:11/812024 REV.A Drawing Scale:3/32"=1.0' — — NEW EQUIPMENT — — — — EXISTING SERVICE i PV—SA-1 2 0A ! i€ I ® • R ! ® B e a e AC—COMBINER PANEL I PV—SA-2 ; �9 AC—CM9-1 I (aa LOADS ONLY) � � AC DISCONNECT II © • • • � AC—aSC-1 113 Ei Bf I I I y� R B N �•: I PV—SA-3 Aj e�R I ( } MAIN e • • • e e ®KR-2 € z f V fUsrl) 8 N B B B I I I MR-6 cc III i II N I I i I EGC I j III Etc EXISTING AC PANEL _ u LGEC EE15TINC IRRf?dERS QIE 5P L!C[ #6 CU 9.660kW DC 8.064kW AC PROPOSED 3-LINE ELECTRICAL DIAGRAM REVISIONS Palacios, Louis GREENLOGI '0 3825 Stars Road d �� ENERGY East Marion, NY 11939 ELIMINATING THE COST of ENERGY 1.) INITIAL SUBMITTAL WITH APPLICATION Page 1 of 3 Drawing No- Palacios-3LD1 Revision: 1 Revised: 11/7/24 EQUIPMENT&COMPONENT SCHEDULE TAG DESCRIPTION SPECIFICATION PV-SA-1 SUB-ARRAY REC460AA PURE-RX EN PHASE IQ8X-80-M-US, 1-CIRCUIT OF 7-MODULES PV-SA-2 SUB-ARRAY REC460AA PURE-RX EN PHASE IQ8X-80-M-US, 1-CIRCUIT OF 7-MODULES PV-SA-3 SUB-ARRAY REC460AA PURE-RX ENPHASE IQ8X-80-M-US, 1-CIRCUIT OF 7-MODULES ELECTRICAL LOAD SUMMARY AC CIRCUITS TAG POWER, MAX VOLTAGE MAX.AC VOLTAGE, NOMINAL RANGE CURRENT PV-SA-1 3220 WATTS 211-264 VAC 13.09 A AC 240 V,AC PV-SA-2 3220 WATTS 211-264 VAC 13.09 A AC 240 V,AC PV-SA-3 3220 WATTS 211-264 VAC 13.09 A AC 240 V,AC PROPOSED EQUIPMENT SPECIFICATIONS REVISIONS Palacios, Louis k_ GREENLOGIC" 3825 Stars Road ENERGY East Marion, NY 11939 ELIMINATING THE COST OF ENERGY 1.) INITIAL SUBMITTAL WITH APPLICATION -gage 2 of 3 Drawing No: Palacios-3LD1 Revision: 1 Revised: 11/7/24 EQUIPMENT&COMPONENT SCHEDULE TAG DESCRIPTION SPECIFICATION AC-CMB-1 AC COMBINER PANEL 250V, 100A, NEMA-1, 1-PH, 3-WIRE BKR-1 CIRCUIT BREAKER, PV-SA-1 MATCH AC COMBINER PANEL BRAND, 2-POLE, 20A BKR-2 CIRCUIT BREAKER, PV-SA-2 MATCH AC COMBINER PANEL BRAND, 2-POLE, 20A BKR-3 CIRCUIT BREAKER, PV-SA-3 MATCH AC COMBINER PANEL BRAND, 2-POLE, 20A AC-DSC-1 AC DISCONNECT SWITCH (LINE TAP) 250V, 60A, NEMA-1, FUSED; FUSE RATING: 50A CONDUCTOR SCHEDULE TAG TYPE CONDUIT AWG. / EGC A USE-2/PV/UF 3/4" PVC-40 12 / 6 B THWN-2 1-1/2" PVC-40 4 / 4 C THWN-2 1-1/2" EMT 4 / 4 1.)CONDUCTOR TYPES AND SIZES TO BE ADJUSTED FOR TEMPERATURE, DISTANCE,AND DERATING FACTORS. 2.) ELECTRICAL CONDUIT TO BE MIN. PVC SCHEDULE 40,ADJUST FOR SITE CONDITIONS. 3.) ALL ELECTRICAL MATERIALS AND INSTALLATION METHODS TO COMPLY WITH NEC AND LOCAL CODE REQUIREMENTS. 4.) NOTE: GROUNDING ELECTRODE CONDUCTOR TO BE#6 COPPER MINIMUM. PROPOSED EQUIPMENT SPECIFICATIONS REVISIONS Palacios, Louis GREENLOGICO 3825 Stars Road ENERGY East Marion, NY 11939 ELIMINATING THE COST OF ENERGY 1.) INITIAL SUBMITTAL WITH APPLICATION Page 3 of 3 Drawing No: Palacios-3LD1 Revision: 1 Revised: 11/7/24 ENPHASE. ,, "fMJ�t'pali. p s y • i If -. , IQ8X Micrcinverter Easy tomstall Our newest IQ8 Series Microinverters are the industry's first microgrid-forming",software-defined Lightweight and compact with plug microinverters with split-phase power conversion capability to convert DC power to AC power and play connectors efficiently.The brain of the semiconductor-based microinverter is our proprietary application- „Power line communication(PLC) specific integrated circuit(ASIC),which enables the microinverter to operate in grid-tied or between components off-grid mode.This chip is built using advanced 55-nm technology with high-speed digital logic Faster installation with simple;two-wire and superfast response times to changing loads and grid events,alleviating constraints on battery cabling sizing for home energy systems. IQBX Microinverter is the latest addition to this family,designed to support PV modules with high High productivity and reliability output DC voltage and cell counts,such as 80-half-cut cells,88-halt-cut cells and 96-cells. 'Produces power even when the grid is.. down p; Moee`than one million cumulative hours . oftestmg h i Glass II dou4le-insul ate d enclosure Optimized for the latest high-powered, Y r Part of the Enphase Energy System, I08 Series Microinverters redefine 108 Series Microinverters integrate with reliability standards with more than one Microgrld forming the IQ Battery,IQ Gateway,and the million cumulative hours of power-on Complies with the latest advanced grid Enphase App monitoring and analysis testing,enabling an industry-leading support software. limited warranty of up to 25 years. Remote automatiou`pdates foi the latest grid requirements d.. .a Configurable to support awk a range of grid profiles Meets CA,RuIe 21(UL`Y1741 SA)and IEEE 1547 2018(UL 1741-SBCERTIFIED NOTE:, Connect PV modules quickly and easily IQ8 Series Microinverters are UL Listed iris series Microinverters cannot be mtzed wan„ to the IQ8 Series Microinverters with as PV rapid shutdown equipment and previous generationsol Enphasemicromverters(107 integrated MC4 connectors. conform with regulations when installed series 168saries And so`on)in the dame system.>;:, according to the manufacturer's lO Microinverters ship with default settings that instructions. ,:-meet North America's IEEE'1547,ihterconnecitoii standard requirements.Region specific adjustments maybe requested by an Authority :, _-'.;Having Jurisdiction(AHJ)br utility representative,,; according to the IEEE 1547.interconcectron _ *Meets UL 1741 only when installed with 10 System Controller 2 or 3. standard An IQGateway is required tomakethese", c tinges during mstailatiori. 0 2024 Enphase Energy.All rights reserved.Enphase,the a and CC logos,10,and certain other marks listed at s , https://on s�hase;coin/trademark-usaQe-Auidelines are trademarks of Enphase Energy,Inc.In the U.S.and other countries. Data subject to change. 108X-MC4-DSH-00185-3.0-EN-US-2024-02-12 I I08X Microinverter INPUT „ i is Commonly used module pairings W 32U-540. Module compatibility _ To meet compatibility,PV modules must be within the following maximum Input DC voltage and maximum module I,. Module compatibility can be checked at https_//enphase.c�m/installers/microinverters/calculator MPPT voltage range v 43-60 Operating range v 25-79.5 Minimum andimaximum start voltage V 30-79.5 Maximum input DC voltage V 79.5 Maximum continuous operating DC current. A 10 Maximum input DC short-circuit current A 16 Maximum module I -A 13' Overvoltage class DC port — 11 PC port backfeed current mA 0. PV array configuration _ Ungrounded array;no additional DC side protection required;AC side protection requires a maximum of 20 A per branch circuit i 1A /: ai 1 A: :1@20840 Peak 'output power - VA 384 _ 366 - Maximum continuous output power VA 380 360 Nominal grid Vditage(L L) -�v 40 splif- Rase(L-L),,180 208,sin le- hase(L-L;120 `,2 rx Minimum and maximum grid voltage 2 V 211-264 183-229 Max.continuous output current - A 1.58 1.73' Nominal frequency Hz 60 4Y�68 Extended frequency range Hz, AC short circuit fault current over three cycles Arms 2.70 Maximum units per 20 A(L-L)branch circuit' ' = 10, 9 Total harmonic distortion % <5 Overvoltage class AC port`, AC port backfeed current mA 18 Power factor setting — 1.0 Grid-tied power factor(adjustable) — 0.85 leading...0.85 lagging Peak efficiency; °l 97;3 97.0 CEC weighted efficiency % 96.5 96.5 Nighttime power.consumption Mw ; ,,_ 26 12- DATA Ambient4emP erature'ran a 40 Cto6�v C(40°Fto149°F)� Relative humidity range 4%to 100%(condensing) DC connector type IStaubli'MC4 Dimensions(H K W x D);Weight 212 mm MY)•175 mm(6.9")=30.2 mm(1.2");1.1 kg(2.43 lb) .Cooling 'Natural convection-no fans Approved for wet locations;Pollution degree Yes;PD3 Enclosure Class 11 double-insulated,corrosion-resistant polymeric enclosure Environmental category;UV exposure rating NEMA Type 6;outdoor COMPLIANCE CA Rule 21(UL 1741 SA),UC 62109-1,`IEEE 1547:2018(UL VM4 88);FC61P 75"Class B;ICES-0003'Class B,CAN/CSA-C22.2 NO.`707.1-Oti ` Certifications This product is U,L Listed as PV rapid shutdown equipment and conforms with NEC2014;NEC 2017,NEC 2020,,and.NEC`2023'section 69012 and C22:1-2018 Rule 6448 rapid shutdown of PV systems for AC and DC conductors when Installed according to the manufacturer's instructions. (1)No enforced DC/AC ratio. (2)Nominal voltage range can be extended beyond nominal If required by the utility. (3)Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. (4)108X Is not certified for use with Enphase Three Phase Network Protection Relay(NPR-3P-208-NA)and is,therefore,designed 1o8X-MC4-DSH-00185-3.0-EN-US-2024-02-12 for single-phase operation only.Check with the local utility requirements If you wish to Install single-phase inverters across three phases. - A Ml& IRONRIDGE XR Rail° Family Solar Is Not Always Sunny ..... 1 . Over their lifetime, solar panels experience countless extreme weather events. Not just the worst storms in years, �fiF but the worst storms in 40 years. High winds capable of ripping panels from a roof, and snowfalls weighing ., enough to buckle a panel frame. XR Rails@ are the structural backbone preventing these results. They resist uplift, f protect against buckling and safely and efficiently transfer loads into the Ns Via, building structure. Their superior spanning capability requires fewer ' y roof attachments reducing the number of roof penetrations AY � } and the amount of fl installation time. h I g Force-Stabilizing Curve Sloped roofs generate both vertical and lateral g forces on mounting rails which can cause them to bend and twist.The curved shape of XR Rails® 4 is specially designed to increase strength in both directions while resisting the twisting.This unique feature ensures greater security during extreme weather and a longer system lifetime. Compatible with Flat&Pitched Roofs Corrosion-Resistant Materials XR Rails®are Iron Ridge@ offers All XR Rails®are made of 6000-series compatible with - a range of tilt leg aluminum alloy,then protected with an FlashFoot@ and options for flat anodized finish.Anodizing prevents surface x' other pitched roof roof mounting and structural corrosion,while also providing attachments. applications, a more attractive appearance. ... F• " � n XR Raile Family The XR RailO Family offers the strength of a curved rail in three targeted sizes. Each size supports specific design loads, while minimizing material costs. Depending on your location, there is an XR RailO to match. -rx-yn.,vgvd ' .'vN ...w / W. 4r":n•,`.1 'S" �. .i.2. .. i „jYYr..... XR10 XR100 XR1000 XR10 is a sleek,low-profile mounting XR100 is a residential and commercial XR1000 is a heavyweight among rail,designed for regions with light or mounting rail.It supports a range of solar mounting rails.It's built to handle no snow.It achieves spans up to 6 feet, wind and snow conditions,while also extreme climates and spans up to 12 while remaining light and economical. maximizing spans up to 10 feet. feet for commercial applications. • 6'spanning capability 10'spanning capability 12'spanning capability • Moderate load capability Heavy load capability Extreme load capability • Clear&black anodized finish Clear&black anodized finish Clear anodized finish • Internal splices available Internal splices available Internal splices available Rail Selection The table below was prepared in compliance with applicable engineering codes and standards.* Values are based on the following criteria:ASCE 7-16, Gable Roof Flush Mount, Roof Zones 1 &2e, Exposure B, Roof Slope of 8 to 20 degrees and Mean Building Height of 30 ft. Visit IronRidge.com for detailed certification letters. > 90 s � A None 140 XR10 XR100 R�� � 160 �E 90 12071 20140 N r� 160 90 30 160 90 I 40 HI i pp I 4 160 RO 80 160 RCK l 120 160 `Table is meant to be a simplified span chart for conveying general raii capabilities.Use approved certification,e.fers for actual design guidance. 4 RON RI DGE XR 1008 Rail r r'r r.. r r' See Description !Length Rail Section Properties Property Value Total Cross-Sectional Area 0.582 in' .66 Section Modulus(X-axis) 0.297 in .46 Moment of Inertia (X-axis) 0.390 in' Moment of Inertia (Y-a)ds) 0.085 in Torsional Constant 0.214 in3 Polar Moment of Inertia 0.126 in4 1.99 APPROVED MATERIALS: 2.44 6005-T6, 6005A-T61,6105-T5,6N01-T6 2.34 (34,000 PSI YIELD STRENGTH MINIMUM) .58 ....................................................... - - 1.25_. Clear Part Black Part Description!Length Material Weight Number Number XR-100-132A XR-100-132B XR100, Rail 132'(11 Feet) 6000-Series 7.50lbs. XR-100-168A XR-100-168B XR100, Rail 169'(14 Feet) Aluminum 9.55 lbs. XR-100-204A XR-100-204B XR100, Rail 204"(17 Feet) 11.60 lbs. V1.11 4e ,,,: r Data Sheet 'Enphase Networking Enphase IQ Envoy The Enphase Its Envoy"` corn rn u n i cations gateway delivers solar production and energy consumption data to Enphase Enlighten'm monitoring and analysis software for comprehensive,rernote maintenance and management of the Enphase IQ System. With integrated revenue grade production metering and optional consumption monitoring, Envoy IQ is the platform for total energy management and integrates with the Enphase Ensemble"and the Enphase IQ Battery"' Smart Enables web-based monitoring and control }� Bidirectional communications for remote upgrades •Supports power export limiting and zeroexport applications Simple Easy system configuration using Enphase Installer Toolkit`"mobile app • Flexible networking with Wi-Fi, Ethernet,or cellular Reliable • Designed for installation indoors or outdoors • Five-year warranty To learn more.about Enphase offerings,visit einphase.com Enphase IQ Envoy MODEL NUMBERS 21 Enphase lQ Envoy"A � EnphasetilQ Envoy cornmunlcatlons gateway with integrated revenge glade Pv F., v Alv{12a4Q exPit ANSI C2 20+1 0�5o and o banal consum tlon rrionttorin + 5°l �' rnetenn 4,( _,s, N _� one 200A ct continuous rated produion GT(current tr,8nsforrxter)_,, „�wr s�.v ACCESORIES(Order Seperately) Enphase Ivlobi(e Connect" 'r yak Plug and play industrial grade cellular modern with data pfaj for systerns up to b0 CELLMODEM M1(4i?based LTE M/5 year data plan) rnicroinuerters°,(Available in the US;Canada;MPxico'Puerto Rico and the US Virgin j C€LI MODEM M1 B;{4G based LTE tv1115 year tlata plait) ' Jslandsnwhere there is adequate cellular service m the lnstaliation area} Consumption Monitoring CT Split-core consumption CTs enable whole home metering. CT-200..SPLIT Ensemble Gammucations Krt Installed'at the IQ'Envoy,. i,r camlunicatidris with Enphase 1 ncharge storage 4 h �G�MtVIS KIT 01 �� :` � ���; �'�^y, ���`��, and Enphase EnpoWer'"smart swit�llklnclueles 1156 eable for�coianecton to IQ'� , • �,� � �� ��` �°� � � z � � " Envoy of",Enphase IQ CornC�iraer�"ar[d allows wireless Commuriica�lon r�rith Ench�arge �� � ' s :•3� � .� i �z..a. and EnpoWer �'»* �� `x' " �5�� r tix,�+,�' �.,=*.z au c POWER REQUIREMENTS I Powerregtiirements s1201240:UAC spit phase , MaX2W140VerCUrrentprUteUtfo CPgUIKed Typical Power Consumption 5W CAPACITY Number ofmicroinverters polled� , � tip to 60D � ?�: ,tip r � p? �, �, •.., tN`,.>�o. >..�_ _� � �. ..xi, MECHANICAL DATA [jimensions{WxHx0j, \* 5ic 4g x b x 1 8 )� 213x126x4 to(8 Weight 17.6 oz(498 g) Ambient tem nmentaperature range �Y� �� 40 to 65 C(40 Ito 149 F) � t ng Envirol rating IP30.For installation indoors or in an NRTL certified,NEMA type 3R enclosure. Altitude r x Ta 2000 meters Production CT Limited to 200A of continuous current/250A OCPD-72kW AC Internal aperture measures 19.36mm to support 250MCM THWN conductors(max) UL.2808 certified for revenue grade metering rCo It sum ton CT For electrical servicesta.25UAWith parallel runs upto 500A p v Internal aperture mea`sures,0 84 x 0 96(21k33mt x 24'38mtr1j to suppor a � M fi: `�•�� 310 THWN COndUCt4C R, - * � , UL2808 certified for usat serytce entrance for services up` oLSOVac _ INTERNET CONNECTION OPTIONS IrtegratedVi Fig M 80211b1g/n Ethernet 802.3,Cat5E(or Cat 6)UTP Ethernet cable(not included) Mobile �� w CELLMODEMM1 (4G)ar'GEL LMODEM M1,6{4G)�Not-!ncluded Notethat an nphase Mobile onnei t•cellttlar ?bderrij require yfor all Ensemble installations COMPLIANCE �Gompllance ��' e �H77 a �s` fis777777777777 ,. kk UAL 6'1(0'1{0 7 rg +3 €' S , t VAN/CSA C22 2 No 61 f ! Jig 47 CFR Part 15 G}ass B ICES�003 IECIEN 61010 0 2010, EN50065 1 EN61000 4S,pEttl61000 61,EN6T000 ' Metenng ANSI C12 20 aouracy class 0 5(PV production only) To learn more about Enphase offerings,visit enphase.com ENPHASE. CO 2021 Enphase Energy.All rights reserved.Enphase,the Enphase logo,IQ Envoy,anti other trariema ks or service nary?es are the trade. marks of Enphase Energy,Inc.Data subject to change.06-30 20 21 SOLAV5 MAST MUSTEDa RE7v yq"am' ` a^R° 'a A 5 R L � 3 � STMt 4 2 Z11A M• t'g'7' Y Y`��' �� v � «'� a; i° t �y a •x m 77 n 9 � h + c ' MODULE EURRENT Y � ,r y�y,��,Fjhy�� z��xr_ r,�, �,^�:��ur"%*M iy"a�: +"W�� F��i'� y W«•ay� C• ram'iF ''�" '� 3-?"� Y�,.�_, - " .a, .�,+-..,�„ ,,,c, °dam.a;9,,,. �r-. ..,, `' .,,.,�.: �,� _,>,—. •.�,a,,,4., s�.-.. ..-,ws t�a�,,o�_'� � t�.'ti..., s ..�.. .�.. � �� 4150 -470 •%MAX.EFFICIENCY ■ _ , r• 0TEMP.COEFF. ■ No HETEROJUNCTION TECHNOLOGY ■ %MIN.POWER IN ■ 25 "IE C REC1 1 © PURE-RX SERIES w ® • • G LDATA r t Measurements In Inches 6a9.o, ..�+p ..... �i��LTA ✓.'�:t'&,u�°,�i✓ `.e..»s-..��' '":d:...z.::.w...�»�.s�i,'�..,�..w:......,_.,...,v'.:...:�.�.....,...M.>a-..v....�,...,.,.._:::.s.,.u:a=•� t r 32.2 ......... ....,19: Cell Type 88 half-cut bifacial REC heterojunction cells, with gapless technology Glass,, 0.13 in.sota>glass with anti-reflective surface treatment # ' in accordance with EN12150' . k I Backsheet Highly resistant polymer(Black) 669 66.9 Frame, Anodized aluminum(Black) 4-part,4 bypass diodes, Junction Box IP68 rated,in accordance with IEC 62790 Connectors StbubliMC4PV-KBT4/KST4(12AWG) " in accordance with IEC 62852,IP68on(ywhenconnected'. t' soa,ro91 12 AWG solar cable,66.9 in.+66.9 in. Cable in accordance withEN50618 9aeoe2; �. Dimensions„ 68x47.4x1.2in.(22:oft?} r .I ,,,,. �., .. � 23.420.12.. ... N Weight 501bs � ,a os .... . ........ Origin _ , o Made in Singapore A +. O ttG+L D TA PRE Up �R' CxxxAA€'ureR �' C RT)F(C �C([JN 13 Power Output-Pmnx(Wp) 450 460 470 IEC 61215:2021 IEC61730 2016;UL61730 15Q11925-2,, ;.lgnitability(EN 13501-1 Class E). Watt Glass Sorting (W) 0/+10 - 0/+10. 0/*10` ; IEC 62716 Ammonia Resistance 4 Nominal Power Voltage-VMpp(V) 54.3 54.9 55.4 IEC61701' SaltMist(SM6) _ 0 Nominal Power Current IMpp(A) =: ," 8.29 838 g 4g IEC 61215 2 16 Hailstone 35mm N UL 61730 Fire Type 2 0 Open Circuit Voltage Voc(V) 65.1 65.3 65.6 ISO 14001;IS09001;IEC45001;IEC62941 O to . Short.Circuit current-Ist(A).:,,'' 8,81 8.88 8.95 " sway inPower Density(W/ftz) 20.1 20.5 21.0 take o. DE SE 1.6 21 mk -ywEE_Panel'Efieiency(%) Power Out put-Prnnx(Wp) 343 350 358 O Nominal Power Voltage-VMpp(V) 512 51.7 522 z Nom w inal Pow' Current i,;p(A) 6.70 6.77 1586 P gVol(V) 61.3 61.6 61.8 Open CircuitVolta e V , W (VTY � Short CircuitCurrent Ist(A) " 7.11' 7.17, 7.23' .__ ,^� _ .. Standard RECProTrust Values at standard test conditions(STC:air mass AM 15,irradiance 1000W/m2,temperature 77oF(25oQ,based on a productioncaread wMia tolerance of Pr4•w,V01&Is,e3% t within one watt class.Nommatmodule operatingtempemture(NMOL air mass AM 1.5.irradiance 800W/m',temperature 68oF(20Y).w(ndspeed 3.3 ft/s(I m/,)).'Where xxx illnstalled by an REC..F , indicates the nominal power class(P„sr)at sic above. Certified Professional No YCS Yqs. la. T` .'?"'. � lA1A7•I•._1{.7rz �v` System Size Alt <25 kW 25-500 kW : ...,..:.:... ..,5. ...:€. .� .:..K.:.. Product Warranty(yrs) 20 25 25 Operational Temperature 40°F-185°F Nominal Module Operating * System Voltage,, ,' 1000 V Temperature 44"C_2"C Power Warranty(yrs) 25 25 25 Maximum Test Load(front) +7000 Pa(146 lb/ftz) °' 'Labor Warranty(yis) 0' 25 10 N Temperature,coefficient of'P. -0.24%/K Maximum Test Load(rear) 4000 Pa(83 4(b/ftz) Temperature coefficient of V°C 0.24%/K Power in Year l 98% 98% 98% N Max Series Fuse Rating 2S A ,r .. TM"'o' Annuat,Degradatlpn 0.25% 0.25%- 0.25% ' Temperature coefficient of Ise 0a74/a/K Max Reverse Current 254 *The temperature coefficients stated are linearvalues Power in Year 25 92% 92% 92% °See mstallainlmanual st load IS(sinstructions Design load-Test load/I,5(safety(attar) j� The RFC Pr°Trust Warranty is only available or,panels purchased through an REC to Certified Solar Professional mstaller,Warranty conditions apply.See wwwrecgroup. O com for more details rV Panels per Pallet 33 0 Panels per40ft GO/hi gh 594(18Patlets) a cube container LOV11„<G To HA1!lOf� 1 Panels per 53 ft truck 792(24 Pallets) _ ..__ Available from: Typical low irradiance performance of module at STC: .... .... ,.�....,..a,.».»....,,.,.... ._._..,..✓` Irradiance(W/m2) Founded in1996,REC Group is an international pioneering solar energycompany dedicated to empowering consumers with clean,affordable REC Solar PTE.LTD. ,.. solar power.As Solar s Most Trusted,REC is committed to high qualit,innovation,and a low carbon footprint in the solar materials and solar 20Tua5 South Ave.14 R C C panels it manufactures.Headquartered in Norway with operational headquarters in Singapore,REC also has regional hubs In North America, Singapore637312 Europe,and Asia-Pacific. post@recgroup.com vnvw.recgroup.com