Loading...
HomeMy WebLinkAbout48728-Z aof SOuly��o Town of Southold * * P.O. Box 1179 eta �0 53095 Main Rd, - COUNTY,, Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 46203 Date: 05/29/2025 THIS CERTIFIES that the building GENERATOR Location of Property: 2395 Grandview Dr Orient, NY 11957 S ecB lock/Lot: 14.-2-3.18 Conforms substantially to the Application for Building Permit heretofore,filed in this office dated: 11/18/2022 Pursuant to which Building Permit No. 48728 and dated: 01/12/2023 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: Accessory stand-by generator as applied for. The certificate is issued to: Therms Katrakazos ,Maria Katrakazos Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: 48728 3/21/2023 PLUMBERS CERTIFICATION: tho ' d S' nature �o�aoFse�Tyo�o TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT RENEWED (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE.SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 48728 Date: 01/12/2023 Permission is hereby granted to: Renewal Date: 05/27/2025 Themis Katrakazos PO BOX 388 Roslyn, NY 11576 To: Install accessory stand-by generator at existing single family dwelling as applied for. Must maintain 15 foot setback from property line. Premises Located at: 2395 Grandview Dr, Orient, NY 11957 SCTM# 14.-2-3.18 Pursuant to application dated 11/18/2022 and approved by the Building Inspector. To expire on 05/27/2027. Contractors: Fees: Renewal Fee $117.50 Total S117.5 Building Inspector Of SO!/ryol � o Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 �Q sean.devlin(c-town.southold.ny.us Southold,NY 11971-0959 BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Themis Katrakazos Address: 2395 Grandview Dr city:Orient st: NY zip: 11957 Building Permit#: 48728 Section: 14 Block: 2 Lot: 3.18 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: G&S Electric License No: 578ME SITE DETAILS Office Use Only Residential X Indoor X Basement Service Commerical Outdoor X 1st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey Attic Generator X INVENTORY Service 1 ph X Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures Sump Pump Other Equipment: 38kW kohler Generator w/ 300A Whole House Transfer Switch Notes: Generator Inspector Signature: Date: March 21, 2023 S. Devlin-Cert Electrical Compliance Form # # TOWN OF SOUTHOLD BUILD NG DEPT. 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: rN� (2k, DATE 12,1 /Z 3 INSPECTOR OF SOUTyo - — - # TOWN OF SOUTHOLD BUILDING DEPT. COU 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] SULATION/CAULKING [ ] FRAMING /STRAPPING FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PR C/O [ ] RENTAL REMARKS: 1Ce, •ei �iow �5�� P.��► DATE yDz3 INSPECTOR r pE SOUT��� # TOWN OF SOUTHOLD BUILDING-DEPT. �ycouo-m, 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] SULATION/CAULKING [ ] FRAMING /STRAPPING [ FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE'SAFETr-INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOL _ ON [ ] PRE C/O [ ] RENTAL RE ARKS: 1 &CV t ss �, ,� �o �,�� DATE1!7�5V INSPECTOR SOOIyo �# :T0WN'OF SO:UTI' OLD'BUILDINGVEPT: °`�cnuMr,N' 631-7654 802 INSPECTI-ON [ - ] . FOUNDATION 1 ST [ ]' ROUGH PLBG. FOUNDATION 2ND [: ] .INSULATIOWCAULKING [ ] FRAMING 1 STRAPPING [ :] FINAL [ ] FIREPLACE & CHIMNEY [ ]. FIRE SAFETY-INSPECTION [ ] FIRE-RESISTANT CONSTRUCTION [ . ] FIRE'RESISTANT PENETRATION j ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] .PRE C/O [ ] RENTAL REMARKS: \)p vi P► odo r �ro � O A /I A I DATE f 1 ( � � INSPECTOR FIELD INSPECTION REPORT I DATE COMMENTS FOUNDATION (1ST) �v y ------------------------------------- FOUNDATION (2ND) � z No ROUGH FRAMING& PLUMBING LM d� � r INSULATION PER N.Y-. "3 STATE ENERGY CODE 7 tn�1 cei hn� � rha�r✓ FINAL 71 qL L.-I 7Z, ADDITIONAL COMMENTS jmab o Lai r-e r� w�I z � m w � N � z z� b Y .PSufF°��coG�a l'UWN Ul+'SUU'1'HULD-13U1Lll1N(s llLYA1Z'1'MEN'1' a� Town Hall Annex 54375 Main.RoadY. U.Box 1179 Southold, NY 11971-0959 'Telephone(631) 765-1802 Fax(631) 765-9502 bftps://www.souttioldtoMDa.go 14 Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only PERMIT NO. Building Inspector: NOV 18 2022 Applications and forms must be filled out in their entirety.Incomplete applications Will not be accepted. Where the Applicant is nbt.the owner,an- T y Owner's Authorization form'(Page 2)shall be completed.,,- Date: OWNER(S)OF PROPERTY: Name; �m { +v �4uS SCTM#1000- Project Address: 2-3 5 G/bxvId Vt ec-d d A ve- o rt evi4 r'1cTS i- A/Y Phone#: Gy�� 2`7 _ ��? Email: a. Y-ep KgZapS ii COS- • Co� Mailing Addlress: Z� WlyiC 1ev- Dn ►-C YhCi11 a lo, 0 CONTACT PERSON: Name: Mailing Address: ZG UV I igCkl eS V 6/J ve yl/l9�l CL�: Phone#: 21 )_�- ?_ 5--C3 Y3 Email: K'Q-+v-k Kgzns ceo co yi- DESIGN PROFESSIONAL INFORMATION: Name: Mailing Address: Phone#: Email: CONTRACTOR) INFORMATION: Name: --rhe '►'1 i <q oct_ _-fcj& �/} �/ Mailing Address: ZG V✓l1'lC� SST y'l4 i,I �I,,q �S`e_i '-/ !� ) W O Phone#: 611 Zq 5`C.O 3 Email: --Mq+✓u I".Caq� Cto( . COS DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair ❑De lition Estimated Cost of Project: Other L (9-e e Vct i" $ Zo1 ov v Will the lot be re-graded? ❑Yes No Will excess-fill be removed from premises? ❑Yes >(No V 1 r PROPERTY INFORMATION ' Existing use of property: Intended use of property: Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes KNo IF YES, PROVIDE A COPY. Check Box After Reading: The owner/contractor/desleq.professlonal Is responsible for all drainage and storm water Issues as provlded by hapter 236 of the Town code. APPLICATION,IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County;New Yoik and other applicable taws,Ordinances or Regulations,for the construction of buildings,' additions,alterations or for removal or demolition as herein described.The appiicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on prnriiises and in building(s)for necessary inspections.False statements made Herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law., Application Submitted By(print name): e m L( I6�i c tjCq L� ❑Authorized Agent ❑Owner Signature of Applicant: Date: CONNIE D.BUNCH STATE OF NEW YORK) Notary Public,State of New York SS. No.01 BU6185050 Qualified in Suffolk County COUNTY OF �y Commission Expires April 14,2�f being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract) above named, (S)he is the (Contractor,Agent, Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this day of 20 Gw1 Notary Public PROPERTY OWNER,AUTHORIZATION (Where the applicant is not the owner) I, residing at do hereby authorize to apply on my behalf to the Town of Southold Building Department for approval as described herein. Owner's Signature Date Print Owner's Name 2 F BUILDING DEPARTMENT- Electrical Inspector TOWN.OF SOUTHOLD : Town Hall Annex - 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 Telephone (631) 765-1802.- FAX (631) 765-9502 rogerr(! -�southoidtownny.gov seand a(�southoldtownny gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 0 Company Name: G&S Electric Electrician's Name: Bob Guarriello License No.: 578ME Elec. email:gs1641 @aol.com Elec. Phone No: 516 848 5616 211 request an email copy of Certificate of Compliance Elec. Address.: PO Box 215, Southold, NY JOB SITE INFORMATION (Ali Information Required) Name: PTI ( S R 7-1-ZA Address: r/,,o ®fZr�nJ Cross Street: i QS7 Phone No.: gZ 7 .o ,5"' 40 g 34f Bldg.Permit#: H E'7 ZS email: Tax Map District: 1000 Section: Block: Lot: BRIEF DESCRIPTION OF WORK, INCLUDWQl1 AR, E ©©T GE (Please Print Clearly): 50 Square Footage: Circle All That Apply: Is job ready for inspection?: YES MNO Rough In Final Do you need a Temp Certificate?: YES®,NO issued On Temp Information: (All information required) Service'Size❑1 PhF-13 Ph Size: A # Meters Old Meter# ❑New Service0 Fire ReconnectEl Flood Reconnect[Service Reconnect F�Underg round[Overhead # Underground Laterals 0 1 2 H Frame Pole Work done on Service? 0 Y MN Additional Information: PAYMENT DUE WITH APPLICATION (1)UNAUTHORIZED ALTERATION OR ADDITION TO THIS SURVEY IS A VIOLATION OF SECTION 7209 OF THE NEW YORK STATI EDUCATION LAW.(2)DISTANCES SHOWN HEREON FROM PROPERTY LINES TO EXISTING STRUCTURES ARE FOR A SPECIFIC PURPOSE AND ARE NOT TO BE USED TO ESTABLISH PROPERTY LINES OR FOR ERECTION OF FENCES.(3)COPIES OF THIS SURVEY MAP NOT BEARING THE LAND SMVEYOR•S INKED SEAL OR EMBOSSED SEAL SHALT,NOT BE CONSIDERED TO BE A VAUD TRUE COPY.(4)CERTIFICATION INDICATED HEREON SHALL RUN ONLY TO THE PERSON FOR WHOM THE SURVEY IS PREPARED AND ON HIS BEHALF TO THE TITLE COMPANY,GOVERNMENTAL AGENCY AND LENDING INSTITUTION LISTED HEREON,AND TO THE ASSIGNEES OF THE LENDING INSITUTION CERTIFICATIONS ARE NOT TRANSFERABLE TO ADDITIONAL INSTITUTIONS OR SUBSEQUENT OWNERS. (5)THE LOCATION OF WELLS(W),SEPTIC TANKS(ST)k CESSPOOLS(CP)SHOWN HEREON ARE FROM FIELD OBSERVATIONS AND OR DATA OBTAINED FROM OTHERS. LEGEND 400 Ostrander Avenue, Riverhead, New York I1a01 tel. (551.727.2505 fax. 651.727.0144 CH =CHIMNEY odmin®youngengineering.com CMF =CONCRETE MONUMENT FOUND SANITARY MEASUREMENTS CM5 =CONCRETE MONUMENT SET A B DI =DRAINAGE INLET N EOP =EDGE OF PAVEMENT Hoard W. Young, Land 5urve or ST 40' 42' WSF =ROOF OVER/ Thomas 0. 1Nwolpert, Professional Engineer LPl 56' 37' WOOD STAKE FOUND / WSS =WOOD STAKE SET Douglas E. Adorns, Professional Engineer LP2 65' 23' \✓ • =END OF DIRECTION/DISTANCE Robert 0. Tost, Archltect A \ Robert 5tromski, Architect W E \\ SITE DATA AREA = 44,734 SQ. FT. \ \ *SUBDIVISION-"GRAND VIEW ESTATES"FILED IN THE OFFICE OF THE \ CLERK OF SUFFOLK COUNTY ON JUNE 8,1982 AS FILE NO.7083. \S VERTICAL DATUM =NAVNAVE)(1988) \ CMF 0� \ dot 4le Z'66, 9, "GCQrd y r)z •cS, gj, / \ RCAo �A <!i \\o hhpri r� \ \ B 4 \ \ \\\S PIANO N .O$OW Z ` ` S O N 0 its \ \ N A s `tip \ NLr c0'`o r QO m 'CMF �o 'P w �� o 0 O 19 a n 7i 60 s v1m� P mNp� ~ELL o v Lro A G \ 5A' y't�o �\EG�µR \ a V\ ,as N_ MEo CMF \ SURVEYOR'S CERTIFICATION � GN r / fir✓" *WE HEREBY CERTIFY TOTHEMIS KATRAKAZOS & MARIA KATRA KAZ O S THAT THIS SURVEY WAS PREPARED IN ACCORDANCE Lot 14 WITH THE CODE OF PRACTICE FOR LAND SURVEYS ADOPTED BY THE NEW YORK t o �o "Grand View Estates" \\ C PAo�INERP OR y� n�p STATE ASSOCIATION OF PROFESSIONAL LAND SURVEYORS. s O� O f 0 T\ \ P,\� C` n i' O rO NC PA �3 O 17i- 7 Ab Y a, -1 .r 0 1 \ HOWARD W.YOUNG,N.Y.S. .NO.45 3 �dv`e�E \\ \ CMF "Cjr° \ \ SURVEY FOR THEMIS KATRAKAZOS 8c MARIA KATRAKAZOS LOT 14 "GRAND VIEW ESTATES" b \ ` at Orient, Town of Southold \ Suffolk County, New York N N HEALTH DEPARTMENT U5mlSE FINAL SURVEY r Evo County Tax Map District 1000 Section 14 Block 02 Lot 3.18 n) MAP PREPARED JUNE 23,2021 Record of Revisions REVISION DATE ��0�` AMENDED BUILDING PERMIT DATA JULY 07 2021 ADDRESSES SCDH5 NOICA#1 AVG. 23,2021 �O AMENDED BUILDING PERMIT DATA JAN 26 2022 / DRAINAGE CALC5 FE8.17,2022 FOUNDATION LOCATION APR.05,2022 My FINAL SURVEY SEEL Oa 2022 s I J I O l C O m 40 0 20 40 80 120 0 Scale: 1" = 40' JOB I ..........._...._......................... _......_....- . ... ! �WGN26241_00'iO3-fs 1 OF 1 APPROVED AS NOTED OCCUPANCY OR DATE: B.P# USE IS UNLAWFUL FEE BY. WITHOUT CERTIFICATE NOTIFY BUILDING DEPARTMENT AT OF OCCUPANCY 631-765-1802 8AM TO 4PM FOR THE FOLLOWING INSPECTIONS: 1. FOUNDATION-TWO REQUIRED FOR POURED CONCRETE 2. ROUGH-FRAMING&PLUMBING 3. INSULATION 4, FINAL-CONSTRUCTION MUST BE COMPLETE FOR C.O. IS1rPL��' VIII' 'H ALL CODES OF CONSTRUCTION SHALL MEET THE F�Ir'v1! yGR� STATE & TOWN CODES REQUIREMENTSOFTHE CODES OFNEW �� ��QUI ED AND CONDITIONS OF YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTON ERRORS SOUTHOLD TOWN ZBA SOUTHOLD TOWN PLANNING BOARD SOUTHOLD TOWN TRUSTEES swmwLgjSrgCfMREWRED N.Y.S.DEC RETAIN STORM WATER RUNOFF PURSUANT TO CHAPTER 236 OF THE TOWN CODE. KOHLER. Model: 38 R C LC Multi-Fuel Natural Gas/LPG 09001 Standard Features 4 KOHLER. • Kohler Co. provides one-source responsibility for the NATIONALLY REGISTERED generating system and accessories. • The generator set and its components are prototype-tested, factory-built,and production-tested. 1 Ifr - • The generator set accepts rated load in one step. I�� ���� �' d'�f �� �g9 • A standard five-year or 2000 hour limited warranty covers all systems and components. • Quick-ship (QS) models with selected features are available. See your Kohler distributor for details. • Meets 291 kph (181 mph)wind load rating. • GFCI service outlet installed on the junction box. • RDC2 Controller K�HtER o One digital controller manages both the generator set and transfer switch functions (with optional Model RXT transfer switch). o Designed for today's most sophisticated electronics. o Electronic speed control responds quickly to varying household demand. The Kohler® Advantage o Digital voltage regulation protects your valuable • High Quality Power electronics from harmonic distortion and unstable power Kohler home generators provide advanced voltage and quality. frequency regulation along with ultra-low levels of ° Two-line, backlit LCD screen is easy to read in all lighting harmonic distortion for excellent generator power quality to conditions, including direct sunlight and low light. protect your valuable electronics. • Engine Features o Powerful and reliable 2.2 L turbocharged liquid-cooled • Extraordinary Reliability engine Kohler is known for extraordinary reliability and o Electronic engine management system. performance and backs that up with a premium five-year or o Simple field conversion between natural gas and LPG 2000 hour limited warranty. fuels while maintaining emission certification. • Aluminum Enclosure • Innovative Cooling System Attractive aluminum enclosure allows installation as close ° Electronically controlled fan speeds minimize generator set sound signature. as 18 inches from your home or small business. • Certifications • Quiet Operation o The 60 Hz generator set engine is certified by the Kohler home generators provide quiet, neighborhood- Environmental Protection Agency(EPA)to conform to the friendly performance. J New Source Performance Standard (NSPS)for stationary spark-ignited emissions. o cUL./UL listing, CSA certification standard.are available (60 Hz only). o Accepted by the Massachusetts Board of Registration of Plumbers and Gas Fitters. o Meets NFPA 37 requirements for 18 in. offset for installation. • Approved for stationary standby applications in locations Generator Set Ratings Served by a reliable utility source. Standby Ratings Natural Gas LPG Alternator Voltage Ph Hz kW/kVA Amps kW/kVA Amps 4E8.3 120/240 1 60 38/38 159 38/38 159 120/240 1 60 34/34 142 34/34 142 120/208 3 60 38/48 132 38/48 132 4D8.3 127/220 3 60 38/48 125 38/48 125 120/240 3 60 38/48 114 38/48 114 277/480 3 60 38/48 57 38/48 57 * 50 Hz options available.Contact your Customer Service representative. RATINGS:All three-phase units are rated at 0.8 power factor.Al single-phase units are rated at 1.0 power factor.Due to manufacturing variations,the ratings tolerance is_-LM Standby Ratings.,Standby ratings apply to installations served by a reliable utility source.The standby rating is applicable to varying loads with an average load factor of 80%for the duration of a power outage.No overload capacity is specified for this rating.Ratings are in accordance with ISO-3046/1,BS 5514,AS 2789,and DIN 6271.GENERAL GUIDELINES FOR DERATING:Altitude:Derate 1.3%per 100 in(328 ft.)elevation above 200 m(656ft.).Temperature:Derate 3.0%per 10°C(18°F)temperature above 25°C(77°F).Availability is subject to change without notice.The generator set manufacturer reserves the right to change the design or specifications without notice and without any obligation or liability whatsoever.Contact your local Kohler generator distributor for availability. G4-305 (38RCLC) 6/21 Alternator Specifications r 4 Specifications Alternator • NEMA MG1, IEEE, and ANSI standards compliance for Manufacturer Kohler temperature rise and motor starting. Exciter type Brushless,Wound-Field • Sustained short-circuit current of up to 300%of the rated Leads:quantity,type current for up to 10 seconds. 4E8.3 4,120/240 4D8.3 12,Reconnectable • Sustained short-circuit current enabling downstream circuit Voltage regulator Solid State,volts/Hz breakers to trip without collapsing the alternator field. Material Class H • Self-ventilated and drip-proof construction. Temperature rise 130°C,Standby Bearing:quantity,type 1,Sealed • Windings are vacuum-impregnated with epoxy varnish for Coupling Flexible Disc dependability and long life. Unbalanced load capability 100%of Rated Standby, • Superior voltage waveform from a two-thirds pitch stator and One-step load acceptance 100%of Rating skewed rotor. Peak motor starting kVA: (35%dip for voltages below) • Total harmonic distortion (THD)from no load to full load with 240 V 4E8.3(4 lead) 74 (60 Hz) a linear load is less than 4%. 480 V,380 V 4D8.3(12 lead) 120(60Hz) 88(50Hz) Application Data Engine . Exhaust Engine Specifications 60 Hz 50 Hz Exhaust System 60 Hz 50 Hz Manufacturer Kohler Exhaust manifold type Dry Engine:model,type Residential Powertrain Exhaust temperature at rated kW,dry KG2204T,2.2 L,4-Cycle exhaust, °C(°F) 633(1171) Turbocharged Maximum allowable back pressure; Cylinder arrangement In-line 4 kPa(in.Hg) 7.5(2.2) Displacement,L(cu.in.) 2.2(134.25) Bore and.stroke,mm(in.) 91 x 86(3.5 x 3.4) Fuel Compression ratio 10.5:1 Fuel.System Piston speed,m/min. (ft./min.) 310(1016) 258(847) Main bearings:quantity,type 5,plain alloy steel Fuel type :Natural Gas or LPG Rated rpm 1800 1500 Fuel supply line inlet 1 in.NPT Max.power at rated rpm,kW(HP) Natural gas fuel supply pressure,kPa LPG 47.8(64.1) NA (in.H2O) 1.2-2.7(5-11) Natural Gas 47.6(63.9) NA LPG vapor withdrawal fuel supply Cylinder head material Cast Iron pressure,kPa(in.H2O) 1.2-2.7(5-11) Piston type and material High Silicon Aluminum Fuel Composition Limits* Nat.Gas LP Gas Crankshaft material Nodular Iron Methane,%by volume 90 min. — Valve(exhaust)material Forged Steel Ethane,%by volume 4.0 max. — Governor type Electronic Propane,%by volume 1.0 max. 85 min. Frequency regulation,no-load to Propene,%by volume 0.1 max. 5.0 max. full-load Isochronous C4 and higher,%by volume 0.3 max. 2.5 max. Frequency regulation,steady state -1.0% Sulfur,ppm mass 25 max. Frequency. Fixed Lower heating value, Air cleaner type Dry MJ/m3(Btu/V),min. 33.2(890) 84.2(2260) Engine Electrical Fuels with other compositions may be acceptable.If your fuel is outside the listed specifications,contact your local distributor for Engine Electrical'System further analysis and advice. Ignition system Electronic Battery charging alternator: Lubrication Ground(negative/positive) Negative Lubricating System Volts(DC) 14 Type Full Pressure Ampere rating 90 Oil pan capacity,L(qt.)§ 4.2(4.4) Starter motor rated voltage(DC) 12 Oil added during oil change(on average), Battery,recommended rating for-18°C(0°F): L(qt.)§ 3.3(3.5) Qty.,cold cranking amps(CCA) One,630 Oil filter:quantity,type§ 1,Cartridge Battery voltage(DC) 12 Oil cooler Remote Battery group size P4 § Kohler recommends the use of Kohler Genuine oil and filters. G4-305 (38RCLC) 6/21 Application Data Cooling RDC2 Controller Radiator System 60 Hz 50 Hz AmbEnginent water c pa ity, 45(113) a Engine jacket water capacity,L(gal.) 2.65(0.7) Radiator system capacity,including voltage: 240v 0 O O engine,L(gal.) 13.2(3.5) o Freq: 60.0 Hz Water pump type Centrifugal goo 0 Fan diameter,mm(in.) qty.3 @ 406(16) re - O O O O Fan power requirements(powered by W �+ engine battery charging alternator) 12VDC,18 amps each _o Operation Requirements Air Requirements 60 Hz 50 Hz The RDC2 controller provides integrated control for the Radiator-cooled cooling air, generator set, Kohler@ Model RXT transfer switch, m3/min. (scfm)1- 51 (1800) 51 (1800) programmable interface module (PIM),and load management. Combustion air,m3/min. (cfm) 2.1 (74) 1.8(64) The RDC2 controller's 2-line LCD screen displays status Air over engine,m /min. (cfm) 25(900) 25(900) t Air density=1.20 kg/m3(0.075 Ibm/ft3) messages and system settings that are clear and easy to read, even in direct sunlight or low light. Fuel Consumption* Natural Gas,m3/hr.(cfh)at%load 60 Hz 50 Hz RDC2 Controller Features 100% 13.9 (492) 11.6 (409) • Membrane keypad 75% 11.4 (404) 9.5 (335) 50% 9.3 (327) 7.8 (275) o OFF,AUTO, and RUN push buttons 25% 5.8 (205) 4.8 (169) o Select and arrow buttons for access to system Exercise 3.4 (121) 2:8 (99) configuration and adjustment menus LP Gas,m3/hr.(cfh)at%load 60 Hz 50 Hz • LED indicators for OFF,AUTO,and RUN modes 100% 5.6 (197) 4.7 (166) • LED indicators for utility power and generator set source 75% 4.5 (160) 3.8 (134) availability and ATS position (Model RXT transfer switch 50% 3.2 (114) 2.7 (95) required) 25% 2.1 (75) 1.8 (64) . LCD screen Exercise 1.2 (41) 1.0 (35) o Two lines x 16 characters per line t Nominal Fuel Rating: Natural gas,37 MJ/m3(1000 Btu/ft3) o Backlit display with adjustable contrast for excellent LP Vapor,93 MJ/m3(2500 Btu/ft3) visibility in all lighting conditions LP vapor conversion factors: 8.58 ft.3=1 lb. • Scrolling system status display 0.535 m3=1 kg. o Generator set status 36.39 ft.3=1 gal. o Voltage and frequency o Engine temperature Sound Enclosure Features o Oil pressure • Sound-attenuating enclosure uses acoustic insulation that o Battery voltage meets UL 94 HF1 flammability classification and repels o Engine runtime hours moisture absorption. • Date and time displays • Internally mounted critical silencer. • Smart engine cooldown senses engine temperature • Skid-mounted,aluminum construction with two removable • Digital isochronous governor to maintain steady-state speed access panels. at all loads • Fade-,scratch-, and corrosion-resistant Kohler@ cashmere • Digital voltage regulation: t 1.0% RMS no-load to full-load powder-baked finish. • Automatic start with programmed cranking cycle Sound Data • Programmable exerciser can be set to start automatically on any future day and time,and to run every week or every two Model 38RCLC 8 point logarithmic average sound levels are weeks 53 dB(A) during weekly engine exercise and 61 dB(A) during e Exercise modes full-speed generator diagnostics and normal operation. For o Unloaded exercise with complete system diagnostics comparison to competitor ratings,the lowest point sound levels o Unloaded full-speed exercise are 52 dB(A) and 59 dB(A) respectively* o Loaded full-speed exercise (Model RXT ATS required) All sound levels are measured at 7 meters with no load. , • Front-access mini USB connector for SiteTech- connection Lowest of 8 points measured around the generator.Sound levels at other points • Integral Ethernet connector for Kohler OnCue�Plus around generator may vary depending on installation parameters. g • Built-in 2.5 amp battery charger • Remote two-wire start/stop capability for optional connection of a Model RDT transfer switch See additional controller features on the next page. G4-305 (38RCLC) 6/21 C KOHLER® PhoneKOHL 9 CO.,Kohler,Wisconsin 9-164 USA' Phone 920-457-4441,Fax 920-459-1646 For the nearest sales and service outlet in the US and Canada,phone 1-800-544-2444 KOHLERPower.com Additional RDC2 Controller Features Available Options, Continued • Diagnostic messages Starting Aids§ o Displays diagnostic messages for the engine, generator, ❑ Block Heater,120 V,1 Ph Model RXT transfer switch, programmable interface ❑ Block Heater,240 V,1 Ph module(PIM), and load management device ❑ oil Pan Heater,120 V,1 Ph o Over 70 diagnostic messages can be displayed ❑ Oil Pan Heater,240 V,1 Ph • Maintenance reminders § One block heater or oil pan heater is recommended for ambient • System settings temperatures below 0°C(32°F). At temperatures below-18°C(0°F), o System voltage,frequency,and phase installation of both heaters is recommended.. o Voltage adjustment Automatic Transfer Switches and Accessories o Measurement system, English or metric ❑ Model RDT Automatic Transfer Switch • ATS status (Model RXT ATS required) ❑ Model RXT Automatic Transfer Switch o Source availability ❑ Model RXT Automatic Transfer Switch with Combined o ATS position (normal/utility or emergency/generator) Interface/Load Management Board o Source voltage and frequency ❑ Load Shed Kit for RDT or RXT • ATS control (Model RXT ATS required) ❑ Power Relay Modules(use up to 4 relay modules for each o Source voltage and frequency settings load management device) o Engine start time delay Maintenance o Transfer time delays ❑ Maintenance kit(includes air filter,oil,oil filter,and spark plugs) o Fixed pickup and dropout settings Miscellaneous o Voltage calibration ❑ Rated Power Factor Testing • Programmable interface module(PIM) status displays Literature o Input status (active/inactive) ❑ General Maintenance Literature Kit o Output status (active/inactive) ❑ Overhaul Literature Kit • Load control menus ❑ Production Literature Kit o Load status Warranty o Test function ❑ Extended 5-Year/2000 Hour Comprehensive Limited Warranty Generator Set Standard Features ❑ Extended 10-Year/2000 Hour Comprehensive Limited Warranty • Aluminum sound enclosure with enclosed silencer • Battery rack and cables Dimensions and Weights • cUL/US listed, CSA certified Overall Size,L x W x H,mm(in.): 1880 x 836 x 1169 • Electronic, isochronous governor (74 x 32.9 x 46.0) • Flexible fuel line Shipping Weight,wet,kg(lb.): 621 (1370) • Gas fuel system (includes fuel mixer,electronic secondary Weight includes generator set with engine fluids, sound enclosure, gas regulator,two gas solenoid valves, and flexible fuel line silencer,and packaging. between the engine and the skid-mounted fuel system components) • GFCI service outlet, 120/240 V for customer connection • Integral vibration isolation • Line circuit breaker H • NEC prime mover shutdown switch • Oil drain extension • OnCue@ Plus Generator Management System W—� L • Operation and installation literature • RDC2 controller with built-in battery charger NOTE:This drawing is provided for reference only and should not be • Standard five-year or 2000 hour limited warranty used for planning installation.Contact your local distributor for more detailed information. Available Options DISTRIBUTED BY: Controller Accessories ❑ Lockable Emergency Stop(lockout/tagout) ❑ Programmable Interface Module(PIM) (provides 2 digital inputs and 6 relay outputs) Electrical System ❑ Battery ❑ Battery Heater ❑ OnCue®Plus Wireless Radio Kit ©2021 Kohler Co.All rights reserved. G4-305 (38RCLC) 6/21