HomeMy WebLinkAbout50780-Z 41 souryo Town of Southold
~� P.O. Box 1179
�04 53095 Main Rd
°�y�oaartr�, Southold, New York 11971
CERTIFICATE OF OCCUPANCY
No: 46173 Date: 05/20/2025
THIS CERTIFIES that the building SOLAR PANEL
Location of Property: 615 E Gillette Dr East Marion, NY 11939
Sec/Block/Lot: 3 8.-4-13
Conforms substantially to the Application for Building Permit heretofore,filed in this office dated: 04/23/2024
Pursuant to which Building Permit No. 50780 and dated: 06/04/2024
Was issued, and conforms to all of the requirements of the applicable provisions of the law.
The occupancy for which this certificate is issued is:
Roof-mounted solar panels to an existing single-family dwelling as applied for.
The certificate is issued to: Christina Sun
Of the aforesaid building.
SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL:
ELECTRICAL CERTIFICATE: 50790 5/16/2025
PLUMBERS CERTIFICATION:
AutLrizU Signature
SaFFnt,�� TOWN OF SOUTHOLD
1% + BUILDING DEPARTMENT
y TOWN CLERK'S OFFICE
"o • SOUTHOLD NY
BUILDING PERMIT
(THIS PERMIT MUST BE KEPT ON THE PREMISES
WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS
UNTIL FULL COMPLETION OF THE WORK AUTHORIZED)
Permit#: 50780 Date: 6/4/2024
Permission is hereby granted to:
Sun, Christina
616 E Gillette Dr
East Marion, NY 11939
To: install roof-mounted solar panels to existing single-family dwelling as applied for.
At premises located at:
616 E Gillette Dr, East Marion
SCTM # 473889
Sec/Block/Lot# 38.4-13
Pursuant to application dated 4/23/2024 and approved by the Building Inspector.
To expire on 1214/2025.
Fees:
SOLAR PANELS $100.00
ELECTRIC $125.00
CO-ALTERATION TO DWELLING $100.00
Total: $325.00
Bui Wng Inspector
SO�I�OI
0
Town Hall Annex Telephone(631)765-1802
54375 Main Road
P.O.Box 1179 G Q Jame
shla7southoldtownny.aov
Southold,NY 11971-0959
OOUNT`I,�
BUILDING DEPARTMENT
TOWN OF SOUTHOLD
CERTIFICATE OF ELECTRICAL COMPLIANCE
SITE LOCATION
Issued To: Christina Sun
Address: 615 East Gilette Drive city:East Marion st: New York zip: 11939
Building Permit#: 50780 section: 38 Block: 4 Lot: 13
WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE
Contractor: Empire Electric LLC Electrician: Steven Leggio License No: ME-57024
SITE DETAILS
Office Use Only
Residential X Indoor X Basement Service
Commerical Outdoor X 1st Floor Pool
New X Renovation 2nd Floor Hot Tub
Addition Survey Attic Garage
INVENTORY
Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan
Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors
Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors
Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO
Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors
Disconnect Switches 4'LED Exit Fixtures Sump Pump
Other Equipment: 9.02kw roof mounted pv solar energy system with 22 panels [Qpeak Dou Blk ML-G10
410] 22 micro inverters[IQ8MC-72-M-US] 1 enhasee combiner panel 2 fused ac disconnects
Notes:
SOLAR PV SYSTEM
Inspector Signature: Date: May 16, 2025
615 east gilette dr
500
hO g SOUTyO�O
* * 'TOWN OF SOUTHOLD BUILDING: DEPT.
-um, 631-765-1802
-INSPECTION
[ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG.
[ ] FOUNDATION 2ND [ ] INSULATION/CAULKING
[ ] FRAMING /STRAPPING [ v]/FINAL c5o1AV—
[ ] FIREPLACE & CHIMNEY [ ] FIRE.SAFETY INSPECTION
[ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION
[ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL)
[ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL
REMARKS: Oe�4 G26� ilGJe. Aida- d�--
DATE /—,9 O—07 S" INSPECTOR
ho�aOF SOGIyO� 50 0 0 � / 5 fi' ' G` l l� to -
* # TOWNS OF- SOUTHOLD BUILDING DEPT.
631-765-1802
INSPECTION
[ ] FOUNDATION 1 ST/ REBAR [ ] -ROUGH PLBG.
[ ] FOUNDATION 2ND . [ ] INSULATION/CAULKING
[ ] FRAMING /STRAPPING [ ] FINAL
[. ] .FIREPLACE &.CHIMNEY [ ] FIRE SAFETY INSPECTION
] FIRE RESISTANT CONSTRUCTION j ] FIRE RESISTANT-PENETRATION
[ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL)
[ ] CODE VIOLATION [ ] PRE C/O - [ ] RENTAL
REMARKS: Jo let r
GrmwA cv ne u"k nol +o be, boJvcA
o 61q plkvL5 40 mov ru
Q
DATE INSPECTOR
# # TOWN OF SO THOLD BUILDING DEPT.
Comm 631-765-1802
INSPECTIO-N
[ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG.
[ ] FOUNDATION 2ND [ ] .INSULATION/CAULKING
[ ] FRAMING /STRAPPING [ ] FINAL
( ] FIREPLACE &'CHIMNEY [ ] FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT CONSTRUCTION [ . ] FIRE RESISTANT PENETRATION
[ ] ELECTRICAL (ROUGH) UC] ELECTRICAL (FINAL)
CODE VIOLATION [ ] PRE C/O [ ] RENTAL
REMARKS: S0
--ne-toL ewmv ao-nckl jo"c5co
DATE INSPECTOR INSPECTOR
souryolo � 6 15 r. U c L LC l l{ of i
* # TOWN OF SO.UTHOLD-.BUILDING DEPT.
co .631-765-1802
INSPECTION
[ ]. FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG.
] FOUNDATION 2ND [ ] INSULATION/CAULKING. _
[ ]. FRAMING/STRAPPING [ ] FINAL
[ ] -FIREPLACE.&.CHIMNEY [ ] 'FIRE.SAFETY INSPECTION
[ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION
[ . ] ELECTRICAL (ROUGH) 11CJ ELECTRICAL (FINAL)
[ ] CODE VIOLATION ( ] PRE C/O [ ] RENTAL
REMARKS:
DATE o'��1 oZf� INSPECTOR
4
1.I '�`,�
� ~ � ,
i
1 f ram, '"i
�� r ,� I l '� ' ,�r:r'r��� r. _
( ' ,y Y /,
,.
. . � .�; ,
E 1 Q{"c-
�. , � - .
k.
t}'
.� ���
. r
�.
�,
kw
`� '/ •''
r ( '
°..
�"`��• �r �` �"
y
,(�� [�yf�
"v'R � y� �`
x ' r''
qy 1 �Idi\
p `�a: f
yT � �!
r � 1
{°
_ � '
� ',i
�'`��'�ura'' "'
_ �`
� �
���
�r�/ �i �.
' R ■rl�
1
A?i;;�'. ? '/' . - ( �f Sir •_—
" 'Y
7,
.r
x
Er
i
WARNWG:PNOTOWLTMC
_. POWER SOMCE
Or
R�T� �EY
e
r -
r,.
i
.j
3
F ,
!ARMNG PHOTOVO'
r
it
r~- -jag..
WARNING PHOTOVOL AI ••
LWARNING
LWARNIN
_ POWER SOURCE
Y
L
i;
C ;
=I
i Al
a
a
PHOTOVOLTAIC SYSTEM
_ EQUIPPED WRH
RAPID SHUTDOWN
C
1
IjA PR 8 2025
To��r� vantrth_�
4
1
1�
y � 6
,
! b
4
t APR - 8 2025"ro i
W►y CDC
� r
z
r`
n
� �•
..
i �` 1 �.�
� .
� �
'!F
.: � .�
�__
� �
•
� �
f `.
r � �
s
. � �. �' .
.�
�.
_ -�T.
C E I
APR
02
Town
. urn
Q
I ••
4 w ry
4 r
Y a
e
3
4
Y �
1
<n
a
1
t
r�.
�304-,
ENPHASE
,LWARNING
ELECTRIC SHOCK HAZARD
00 NOT TOUCH TERMINALS
TERMINALS ON BOTH THE LINE AN
LOAD SIDES MAY 9E ENERGIZEC
IN TIE UPFN w_.;.'ice
QWARNING
O'JAL POWER SUPPLY_
t
i
l.}
r�'^S,
�..:. .i.
ARN�NZAR' :.
�TR�. r NOES
ELF.•y0 GA.JPC;9�_
R,. Y
m
i
S
r
t
�. M
9.
G
,.wARNINO,PHOTOVOLTA)C
_ - POWER
Ip �
'• __. � j t SPA
f �
• r• ?
un �
i!
f
1
O F�
x
"780
r
luummn Buum:mn
ETR*N SETR"..• �
V EFFICIENT aERCV EFFICIE% OM 36'
250Vac
12svac
..,.... .C� ,3
WE
W�c �w
i
G
f af.
a
• 3 _
.�.,
v
FIELD INSPECTION:REPORT DATE COMMENTS
FOUNDATION(1ST) p
y
-------------------------------------
C
FOUNDATION (2ND)
z
0
ROUGH FRAMING&
PLUMBING
r
INSULATION PER N.Y. ►�-3
STATE ENERGY CODE
Ok- C-O.
FINAL
ADDITIONAL COMMENTS
IlLkA G Z
s� -a
�o
Z
IN m
y.
O-
x
E
y
x
d
ro
y
ao�gu�co�ar�oGy TOWN OF SOUTHOLD—BUILDING DEPARTMENT
co x Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959
as Telephone(631) 765-1802 Fax(631) 765-9502 hgps://www.southoldtownny_g_ov_
Bate Received
APPLICATION FOR BUILDING PERMIT
fp WfmE0VE
For Office Use Only D
PERMIT NO, �" Building Inspector:
APR 2 3 2024
Applications and forms must be filled out"in their entirety.Incomplete
applications will not be accepted. ;Where the Applicant is not th1 "Ie owner,an a �clF�trr� �� "", yynt
O�itiner's Authorization form 2)shall be completed:
Date: 02
OWNER'S)OF PROPERTY
Name: r,�, SCTM#1000-
3 / 3....
_ s
Project Address:
Phone#: j' mall hiAl.s r •- y1/I.-
Mailing Address: l
CONTACT PERSON':
Name: .
Mailing Address: /901t W, 7-31
Phone# Email: I
DESIGN PROFESSIONAL INFORMATION.
Name: .. . . .
Mailing Address:
Phone#: Email.
�_3I.
.
CONTRACTOR INFORMATION:
Name:
y1!1l�d.1/l 5. .. �G( l �ZU/)..
Mailing Address: —" L
r
Phone#: - ,�... d" FM71
.'
DESCRIPTION OF PROPOSED;CONSTRUCTION
El New Struc re YAddition ElAlteration ❑Repair ❑Demolition Estimated Cost Project: .
❑Other Ud D/ C nC n Sly( $
Will the lot be re-graded? ❑Yes &Ko Will excess fill be removed from premises? ❑Yes ❑No
1
PROFERTYdIIVFORMATION
o ,
,
use f-property:
Existing use of promS.4 Intended use o....._ .. .....,.. :,.........._._.._......
Zone or use district in hich premi es is situated: Are there any covenants and,restrictions with respect to.
this property? ❑Yes MNo IF YES,PROVIDE A COPY.
CheC1C BOX After ReBding :The owner/contractor/design;prgfe§sional is responsible for all drainage and storm water issues as provided by:`
Chapter 236 af`R a,,T�t�l`�n de pP A fC�IN IS HEREBY MADE to the�Budding,Die"a' ent for the issuance of a Building Per`mrt pursuant to the Building;2,on,e
' Iyy "i �" pp vices or Regulations,for the construction of buildings,,
Ordinance aft o of ouold fatk)C unty,New York and other a' licable agrees to comply veith'all applicable laws,ortlinances,building code,
ws,Ordlna
additions,alterations or for removalor demoh ion as herelrn descnbed The applicant
j y s.- r nF
housing cod "and regulations and to admit authorized inspectors on'premises-and,in g( l for necessary inspections False statements made herein are
unishab e a .a Cla s A mis a eanor 'reuant to'Section 210 45 of the New York State.penal Lai' °
buildin s
sa i66 ,.0 •� d
p. I ,(..�,. iS,ri< g5
Application Submittediflprint name): UKAuthorized Agent ❑Owner
Signature of Applicant: Date:
STATE OF NEW YORK)
SS:
COUNTY OF )
being duly sworn,deposes and says that(s)he is the applicant
(Name of individual signing contract)above named,
(S)he is the L'z t�::C�
(Contractor,A ent, Cqr orate Officer, etc.)
of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this
application;that all statements contained in this application are true to the best of his/her kn eApndP �f, and
WINthat the work will be performed in the manner set forth in the application file therev4j*VARy PUISLIC-SWE OF NEW YORK
No,01 GRO434884
Swornb fore this 6tary
ualifiedInSuffolkCounty
' I ommis o - 3-2026
ay o
d4N Public
PROPERTY OWNER AUTHORIZATION
(Where the applicant is not the owner)
JG residing at
C'yea j,, / r
a OVf 1153g do hereby authorize l.X,l fwe,5 41- CS/WT /2/� to apply on
my behal o own of Southold Building Department for approval as described herein.
is ure U Date
r '
Print Owner's Name
2
Building Department Application
AUTHORIZATION
(Where the Applicant is not the Owner)
r/ sy, ,
residing at lY/5- �l l�%
(Print property owner's name) (Mailing Address)
IU YlJ do hereby authorize Gam( file S
(Agent)
�fl to apply on my behalf to the
Southold Building Department.
(O nature) (D e)
_.
05
�G
(Print Owner's Name)
a zr.:�,
�Si1FF014,� BUILDING DEPARTMENT-Electrical Inspector
TOWN OF SOUTHOLD
Town Hall Annex- 54375 Main Road - PO Box 1179
� �� � Southold, New York 11971-0959
Telephone (631) 765-1802 - FAX (631) 765-9502
jamesh@southoldtownny.aov-seand@southoldtownnv:clov
APPLICATION FOR ELECTRICAL INSPECTION
ELECTRICIAN INFORMATION (All;lnlormation Required) Dater 04-02-2024
Company Name::,
Electrician's Name: t
License No.:.fY1 =' Elec. email: vOY
V1
Elec. Phone No:XiJLc-aIg o-4,a5C� 9,request an email copy of Certificate of Compliance
Elec. Address.:1,` ova' p;` . 'to 3._ eriu t d L-A-vX4,
JO$ SITE INFORMATION (All Information Required)
Name: Christina Sun
Address: 615 East Gilette Drive, East Marion NY 11939
Cross Street: Manor Place
Phone No.: 631-333-2288
Bldg.Permit#: email:christina@bowsprite.com
Tax Map District: 1000 Section: Block: Lot:
BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly):
Addition of 22 solar modules on roof of main house.
Square Footage:
Circle All That Apply: ,
Is job ready for inspection?: ❑ YES ❑NO ❑Rough In ❑ Final
Do you need a Temp Certificate?: ❑ YES ❑NO Issued On
Temp Information: (All information required)
Service Size❑9 Ph❑3 Ph Size: A #Meters Old Meter#
❑New Service❑Fire Reconnect[]Flood Reconnect❑Service Reconnect❑Underground[-]Overhead
# Underground Laterals 1 2 F1 H Frame Pole Work done on Service? Y ON
Additional Information:
PAYMENT DUE WITH APPLICATION
A4mro, s J. S TOUT A R C H I T E CT & Assoc .
2 G R E G L ANE li' AST NORTHP0R TN. Y. 631 — 8 58 9388
Letter of Certification
April 18, 2024
RE: Sun Residence
615 East Gillette Drive
East Marion, NY 11939
To whom it may concern:
I, James J. Stout, registered architect NYS license number 021633 would like to
submit the following:
I have inspected and analyzed the roof structure at the above mentioned address
and have determined the structure and the panel attachment to be adequate to
support the new additional load imposed by the proposed solar panel system and
complies with the 140-mph wind design load as per 2020 Residential code of NYS
(RCNYS), 2020 Energy conservation construction code of NYS(ECCCNYS),the
Long Island Unified Solar Permit Initiative(LIUSPI) and the ASCE 7-16.
The existing 2"x 6" @ 16"o.c. roof rafters will provide the required support.
Thank you,
James J. Stout
Architect
0.21 33 OQ
qrF F ESN y
ROOF PLAN GENERAL NOTES JOB NO.
2024—SO6866
1. SOLAR PANELS WILL BE ( 22 ) Q.CELL 410 WATT PV MODULES, AND (22)
ENPHASE IQ8M-72-2-US MICRO-INVERTERS.
2. PROVIDE A.C. DISCONNECT: CUTLER HAMMER DG22CVRB-30A GENERAL J
DUTY SAFETY SWITCH, NON FUSIBLE, 240VAC, NEMA 3R.
ILL
3. THE AC DISCONNECT WILL BE LABELED AS "UTILITY DISCONNECT AND Z
PHOTOVOLTAIC SYSTEM LOCK-OUT' LOCATED WITHIN VIEW OF THE ELECTRIC Z O r
UTILITY METER. Q
4. IF IT IS NOT PRACTICAL TO LOCATE THE AC DISCONNECT WITHIN VIEW OF j L I
THE UTILITY METER, THEN A WEATHERPROOF PLAQUE SHOWING THE LOCATION LU 'CIE
Q
w' OF THE SWITCH MUST BE INSTALLED WITHIN VIEW OF THE ELECTRIC UTILITY D:
a METER.
5. ALL WIRING TO MEET THE NATIONAL ELECTRICAL CODE. J
6. THE RAFTERS AS INDICATED HAVE BEEN ANALYZED AND DEEMED SUFFICIENT J <
TO SUPPORT THE ADDED LOAD OF THE SOLAR PANELS AND CONNECTORS. N Q W rr ll
7. THE SOLAR PANELS MAY NOT BE INSTALLED ON AN EXISTING ROOF THAT
HAS MORE THAN 1 LAYERS OF ASPHALT ROOF SHINGLES, UNLESS ADEQUATE
IF . MEANS OF SUPPORT ARE PROVIDED AS PER THESE DRAWINGS. O z
00
00
8. THE MAXIMUM SPACING BETWEEN THE STANDOFFS SHALL BE 64" O.C. \It J LLI Q m
9. THE SOLAR PANEL MOUNTING SYSTEM WILL BE BY IRON RIDGE XR100 WITH LLI ~ 00
A 2 1/2" ALUMINUM BEAM z D, Lo
Go
o Q 0) QLd
x
ZONING INFORMATION 0- U W
STREET ADDRESS: 615 EAST GlLLETTE DRIVE,
EAST MARION NY 11939 Q W z z O
SEC: 38 BLOCK: 4 LOT. 13 O J J C3i7
t/) fn W =J Z z
LINE DIAGRAM z IY O O z
STRING 1 ( CONNECTED TO PV MODULES ) z (n Q a
E--
STRING 2 ( CONNECTED TO PV MODULES ) } O r n < O O
m V/ Li z
o
0 L: Lo (f) O C/)
f; o l0 CO W Of LJ
LLj
AC ►� z
COMBINER N
EXISTING 200 P NEMA 3R � LL Q
METER PANEL IN (2) 2POLE O M�M
HOUSE B40 AMP REAKER W I2 V LLLI
LU d a W
TOTAL SYSTEM SIZE: 9.02 KW cc O I C0
6
c
IND AS NO D z To 0 z
Q. o � Xf
ATTACHMENT DETAIL Q N I a
jz —
3_a,, COMPLY WITH ALL CODES OF SOLAR PANEL MODULE 3 �
W'FYBLIMING DEPAATMEtI+ITAT NEW YORK STATE& TOWN CODES O c0 0 0
'�-18M 8AMTO4PM FOR THE AS REQUIRED AND C NDITIONS OF _ `� Z
CuiPANCY OR FOL OMNG INSPECTIONS:
SOUTHO TOWN ZBA �
1. FOUNDATION-TWO REQUIRED
U IS UNLAWFUL FOR POURED CONCRETE ' ALUMINUM ALLOY L-FOOT ALUMINUM XR100 RAIL BY
SO LD TOWN PLANNING BOARD IRON RIDGE
q��' ��,///�����, wk
2 ROUGH-FRAMING&PLUMBING S� OLD TOWN TRUSTEE$ `r ASPHALT PV FLASHING �` •.. '','0
IT'I�OUT CERTIFICA� ROOF SHINGLE --- ---- -- - ---- - •••:d, S
3 INSULATION J� •'
4► FINAL-CONSTRUCTION MUST S.DEC -- - -- - ---------- -_-- Q ; ��';3�
F OCCUPANCY BE COMPLETE FOR C.O. OnOLD HPC EXISTING ROOF = :-s N:z
-Lu• �
SHEATHING z W e N �:Ll.
ALL CONSTRUCTION SHALL MEET THE SCHD 5/16" X 4 1/2' STAINLESS STEEL c6:
REQUIREMENTS OF THE CODES OF NEW EXISTING ROOF RAFTER LAG BOLTS INTO CENTER OF ROOF �i`Y • ���/
ELECTRICAL YORK STATE. NOT RESPONSIBLE FOR RAFTER, MINIMUM 3' EMBEDMENT. '�i��j•.; ��
DESIGN OR CONSTRUCTON ERRORS ' ••••••••• `,'�''
INSPECTION REQUIRED
PRIOR TO CUTTING OR ORDERING OF MATERIAL JOB NO.
OR PLACEMENT OF THE L-FOOT ATTACHMENT, 2024—S06866
FIELD VERIFICATION OF EXACT RAFTER
LOCATIONS ARE REQUIRE TO COMPENSATE FOR 36" GROUND OUTLINE OF ROOF
PREEXISTING RAFTER IRREGULARITY THAT MAY ACCESS AREA
EXIST. 36" MINIMUM-
ROOF ACCESS \\� �i' �___.� N U.
\\ I N
THESE DRAWINGS COMPLY WITH THE �� ,' r_� � Z �
2018 IRC AND 2020 NEW YORK 18" MINIMUM �________________________J' I 2 Z
STATE RESIDENTIAL BUILDING CODE. VENT AREA ° I
--------------------------- I I W W Q
HATCHED AREA
`\ !--'- ------------- -� 1 cc � aQ
NOTE: ALL ROOF MOUNTING INDICATES LOCATION `��--- -- '� i I
BRACKETS SHALL BE PROPERLY OF SOLAR PANELS I L_ _�
i
0
SECURED TO A ROOF RAFTER. ° �� °�---- -•--- --J N
THIS PROPERTY PRODUCES THE O Z_ L
ROOF ACCESS PATHWAYS AS DRAWN. W
REQUIRED GROUND ACCESS TO THE F OF T \ E-' 000
0
c} J LLl m
Ld HousE W ,_, a,
Q z ct n00
THESE DRAWINGS HAVE BEEN DESIGNED IN a- L icn
ACCORDANCE WITH THE (AF & PA) WOOD EAST GILLETTE DRIVE, 0 � w �" o
FRAME CONST. MANUAL FOR ONE AND TWO
FAMILY DWELLINGS. ROOF PLAN/PANEL LOCATION z I`_
w
SCALE 1/16"=1'-0" (n W =I z z z
THE ACTUAL IN FIELD ATTACHMENT TO z Q� 0 O
THE ROOF WILL MEET OR EXCEED NY S 0 Q
� Z °� a
z
RESIDENTIAL CODE REQUIREMENTS Q z 0
O V) Lj O o
GROUND ACCESS POINTS ARE NON-OBSTRUCTED m d. F- �.., z
PER 2018 IRC AND 2020 NEW YORK STATE o O Lo Q W
RESIDENTIAL BUILDING CODE. w
o W
2" X 8" RIDGE � z
Q
Q—CELL 410 TIES COLLAR"0 48" O.C. 0 0) Q `0
SOLAR MODULES W Q 0) O ^ (�
W "t •- r_,
IRONRIDGE FX SYSTEM 2" X 6" ROOF Q O I < } W
---- ------ N
LAG BOLTED TO RAFTER ------ ______
RAFTER ® 16" O.C. W O Z
ALUMINUM SUPPORT G_ z
RAIL BY IRON RIDGE O ATTIC I O
Q � �--
O oo o
o Z
EXISTING ASPHALT ROOF SHINGLES `�,� 111111p1
(MAX 1 LAYERS) ON 15# BUILDING ` \�� •• It/,��'
PAPER ON 1/2" PLYWOOD SHEATHING ``` ..•••J.�i,��i
J� •o
co
N•Z�
ROOF CROSS SECTION "W `n
=d: o;or
SCALE 1 4 =1 -0 ''�.,���� ......•• �•
44'-9. JOB NO.
IDGE LINE 2024—SO6866
18" MIN
` - -- - - - -- - -- -- - - ---- ---- - - ---- - - - - - --- - _ VENT AREA M
j.. OUTLINE OF ROOF Z
0 pZ
icoWLu
I
cc
__ . f• . QCELL 410W
SOLAR MODULES
PROVIDE
ALUMINUM SUPPORT BEAM
IX N
N
PROVIDE ALUMINUM STANDOFF 00
O z W
•,. LAG BOLTED TO RAFTER00
W
rn
Lii
SYSTEM LENGTH = 37'-10 1/2- LL I r m
45'-1" z LLI O
NOTE: THIS ROOF WILL HAVE .017 QCELL 410 WATT PV n p w z
MODULE PANELS WITH KW OUT UP T OF (6.97 KW ) AND O (n _-i z
(17) ENPHASE IQ8M-72-2—US MICRO INVERTERS Z C� 0 O [�
PA NELS„SIZE SOLAR PANEL LAYOUT ROOF # 1 0CELL Z Q g x
SCALE 3/16"=1'-0" LINE OF HIP m 0 (n W J z
74.0" ¢ 0 L In (n z f
OUTLINE OF ROOF OC `- Q Q W
O IL L- CO W
- w
MODULE TYPE/ z
00 Q
""'' o PANEL SIZE 0)
00 0` -. w
x
QCELL 410W � O Q w 0
SCALE N.T.S. Q W 1 c� N
SOLAR MODULES a n Lu ZO Z
NOTE: WHENEVER POSSIBLE PROVIDE 2 1/2" a z �
„` ALUMINUM SUPPORT BEAM O
PLACE SMALLER SPAN N I 0
BETWEEN ATTACHMENTS POINTS z ^
TO AN OUTSIDE EDGE OR = �c eon ALUMINUM
RAFTER NDOFF 3
OPENING IN A RUN. cc0 00 o z
SYSTEM LENGTH = 13'-9 1/4` lttl IIIIIIIfill,,i
29'-3- : •'
i
J� •• ••'y0�.0
:�
NOTE: THIS ROOF WILL HAVE . (5) QCELL 410 WATT PV =¢ � �eW=
SOLAR PANEL LAYOUT ROOF # 2 MODULE PANELS WITH KW OUTPUT OF (2.05 KW ) AND •
d 0 moo;
SCALE 3/16"=1'-O" (5) ENPHASE IQ8M-72 '2-US MICRO INVERTERS '
jeI�/b a
�j•••••••••
'���vv�/I/IIIIIIIIIt
PROPERTY LINE
D
Cj�
F- /WMIAIWI
� o
-Fq-I o m
�
F-i m
r-
rz z
�7 m
C i
Fq i I
PROPERTY LINE
0
RAWINGS PREPARED FOR: DRAWN BY: J,N,S DATE: 4/O2/2 4 REVISION NO. N
ED qR
��• s �.sr• PROPOSED SOLAR PANEL INSTALL. N
HORIZON SOLAR For: SUN RESIDENCE
• 615 EAST GILLETTE DRIVE
(631 )-683-4898 p
EAST MARION NY 11939 0�
•:��02163;:Q�.� 1087 FT. SALONGA ROAD 00
�.,��TF••*so* o �• NORTHPORT NY 11768 PLOT PLAN PAGE NO. �
h n NE a,```` 1 0 0 - 0 z
J A M E S J. STOUT ARCHITECT
2 GREG LANE EAST NORTHPORT, NEW YORK (631) 858 9388
JOB NO.
2024—SO6866
O
Z I
Zo
Wo
--- -- - - � a r-
-_ -- -
52IT PANEL -AC SUBPANEL PHOTOVOLTAIC POINT OF PHOTOVOLTAIC SYSTEM
INVERTER OUTPUT CONNECTION DO NOT A INTERCONNECTIONA' --�
EQUIPPED WITH ADD LOADS TO THIS SWITCHBOARD N J
PI UTDQ DO NOT RELOCATE THIS OCPD LINE SIDE TAP INSIDE \
REFLECTIVE LABS S SHALL BE A PV GENERATOR AC A E o Z W
SATED DISCONNECT SWITCH • • • • J �
MAIN SERVICE PANEL OR LOCATION OF MAX AC OPERATING CURRENT: 20A00
• • . . z 0 °C) Lo
POINT OF IlVIERCONNECTION-SOLARA/C 00
o w 0 rn
DISCONNECT NOMINAL OPERATING VOLTAGE: 240V •
20
. • • .
240 Z o
WARNING: PHOT - -- ----- -- - - _ _ g o J z W 3
WARNING TURN OFF PHOTOVOLTAIC, , �, O -i m z
PtIIiER SOURCE ELECTRIC SHOCK HAZARD ' ' • ' z O O �' F
WORKING —
INSIDE
REFLECTIVE LABEL(S) SHALL BE LOCATED:
o
. , wZV) Q O z
EVERY i OFT OF EACH AC/DC RACEWAY. DO NOT TOUCH TERMINALS • • o w Z O o
TERMINALS ON BOTH LINE AND Z a- �- z z
^ F 1 LABEL SHALL BE LOCATED: ON MAIN o Q Q Q
C/�
LOAD SIDES MAY BE ENERGIZED SERVICE PANEL ORPOINTOF o Li- w
SHOCKELECTRIC HAZARDLo
• • • TOUCH INTERCONNECTION z
TERMINALSON • AND ¢ 0� 00 coo _Q
LOAD SIDES MAY • . LABEL SHALL BE LOCATED: o n 00
ON A/C COMBINER SOLAR DISCONNECT W O d
IN THE OPEN • • / Q
a V) zZ W N
o
DUAL POWER SOURCE SECOND SOURCE co 0 O
;q WARNING DUAL POWER RCE 1111111111 Z N .� CL .�
n LABEL SHALL BE LOCATED: METERPAN COND SOURCE IS PHOTOVOLTAIC SYSTEM' 0 o O
--- -
NEC 705.12 (B)(3-4) & 690.59 0 2 � z
[ i- Niz j
iCti �',o:0+
ice• •� �
_- ''lllll/lllllll��
JOB NO.
2024—S06866
.PEAK DUO ML-G10+ ENPHASE IRONRIDGE Flush Mount System
SERIES acell5
395-/15Wp 1132Cell,,
21.1%Maximum Module Efficiency Q
Z r•"
O O
� Z
Breakirq Me I1'e eH<u,•n<y CarrirrT I r r LU
l:,l11111ll1 _ cc �` V
eatable inve.tnwnt _-_-_-.-
L .r•=ss•rwr••
IQ8M and I08A Microinverters d J
E1101.h•Y M+ae parEOE�aoe (1„:xwesl OB Micrpn.«t« - u,tlu 1c,M1r„rncnPld IarrwrG..ohw.ra- - , (N
lar°aarrrr raa aaom.rr.ayorwaan�a�•• W! Vn fan eepeaatYb Corrvlrt OC f••yto blind
rr ,wed.-care •ar. ww«ro AC Po.«emci«rn rase �» K«a�mm.lrwamkrar�w,t« �,..gn,r.a�or,«.n wan v..:
«.,p�«rt>r,>ppl�•,�a napal�tl ��t��)whbhwwbbs �.e�«w..r«. N U>
�,,./`�{ Eibeme vnedrerr ,r»m«dm«t«toop«ae prdted«oe gr.-iIs..Thla cfvp eta,d'W Letwwn•r`c .r IPlc.
";-' rtw•.e.Taw',".n an«a Wvancetlw'-mm techndogy xnm hpn-aPe•tl tlp ibgk errtl hu«zperl•at tweet ab�rwn vmnarFt+r..: O � r
raaporrse tkn«mMazglry bad•aM p.�aroma aswunr°c«n,ntmmbatt«y W
,.vr vw.rsamww°raa«.woow "r'"°e«roar«rw mrenr. uitt for solar's fougnest roofs.
t oCo
vativa ale-waeSeee, w ar•"tl��a"v ronR' builds the sv —
UdMreMaBy n .p war a..a...r Ms•vn rdgs orgest mounting sysrem for pitched roots in solar.Our componants have beery tested to \ L 00
00
..n.+.•xwn.wr^u•art twq• the limit and proven M extreme environments,iecluGing Florida's high-valocay,hurricane Zones.
roue a re.rns ar rigorous approach has lad b uragile slruUural teaturea,such as carved rails and reinforced Hashrgs.and
area a sear-nausea•zbsur: is also why our products are fully cerlirred,code corephant and backed by a 25-Year warranty. i. 1 00
TM nnet tfgrouph tening rta oim.°r u.rn•sr ,01,
r r 1
III�`nnnlll( vayranana In tM�il y °D1«iiotli1" LO
cl/ li 00
'-•L I
'°yr,,.u.xy.,,,,,.n;'wrxv rue wrrv-..mxoaara, ram. yryaevro-r«rxN Strength Tasted PE Certified�•a.r'uw«r�.ar.n-ax.�ero.u.+..r«ro. a+•+-r. ,w.wo•-+m�•°.�a .,.�..w w..�w+.v. cwrw«amm�w m.ar.o.a�,,...r .=
s-ww-w w•+••' ..-a m a.+ra°wa..r.�n v».rwt" ¢ 0)
y'•a .air moa.uo�mr ar ea., AN mmpo�nts evaketed for superior availaPre-stble
in d ost engineering krrrs Q w
yar•awr"waa structural dormanpe. a Ef.1L � V
..,.�r........«�.a".-.r.�.a..r.....o:•.. aaeww.a'ew`aw` I� ��
u.enuwrnn,t mpw«reEa Class A Fire Raring Design Assistant
G•r3ots alL nn-563•E61 W I O
CarYdred h meintam the fire resista,><e ce i so.,., makes it rojets. Q
railrg of the existing too1. c sate.snare.and pace Wgacts. Z
w��rq»x roe K.r.+mwra..0 umr �•�hw•�•'""
a � -v'A01� ••«�� _�� UL 2703 Listed System•am�a°c xrrw..«e...arwwm.. O
TwtrbleMeam m�. >✓ � "c'm'••«°�'�- r.ermerrrar.e.r "` �"-� Ys 25-Year Warranty
C.7�—_ ® U� J•� ��+ rw Entire system and components meet Products guaranteed Io be free
LOJ newest eflecIive UL 2703 standard. of Impalrirg defect,.
sir •�m.r°n n..-r.n----_ r
say. //-1 lF«y
N O 1 1
Z LL �—. �
xx+wrc•oa.amos=newwrmsww __
� LIJ mo w
),PEAK DUO ML-G70+SERIES ---_-__ _ _
=c1lawexalspedlicall - IQBM and IQBAMicroinverters %fl,ORail XRtepRail X1111000Rex 0081 Bonded Splices Q O
0 (n LLI V)
oenP= waw.arr.waw '! �.mWryamoorwaR' . avtJeo aesipp _ Co1 1 L Z
F arn••prr -- LL I\�
�e• Q uw.x«m.rorar r.xe�+aa�werm °ia�"+as.�..rmnoca,Vaw.«rw.o.r4 Z `"'-
Lo (n ~ chi)
sin. a xh«nrab•wr - aw."."nraw..�u.rt.•aup. , v�e,gn ng Splices O
cats Abw-proM1k mounnrg rail Th.Wtimete revdennar A nee I mounn Bontled$bucnxal C-
„a•r r, `- .r• ^� a9 Iv regwns wM kgM snow. solar moumrg cal. cal for cc,al prorects. correct XR Rids rogetne:. Q n I. r O 1. 1 � L••I
•Efectrral CMrectenstin ^^ Wan.r�cur on Q� • integrated bCrtivg s1 LL ltil 1 I 1� a -b'Spanning capability -9 spanning capability 12'Spannng capabaty I atM
a Moderate load capability Heavy kris capetHMy Ememe load c
r�rwwoeu.r< yw •oa aoe •° •» r-r • -Ckar and black lirtisn Clear and black Nish apadMy No tools or tvrdware
E..s.wou,"++caor»as sreacrsvrae>vcc ew u•aara.. oc.nwrKvmv�.m . m •Ckar arodzed final Sexrentenrgstoptad
a�ww > ne u.ar.a _ a >a
k w cares OC (� c0 00
Oww•ww� �` r rn
hw'1 - ^ 0 INO^ SI-W sleeves CA110^ O Q �+a O
nee,,.r • zmr m• ms xv -•r••�0��w��°aw°r°.s"•.e«"r 8und«,9 HardYa.a CON '^ r•l
warrtsa°ra«.enrmrwu orm.w.:«�nm,a rn,: , a ... - .eaeww _j W QL v L LLj
_ r " Me _ w (0/� d �
,,,,°, v. M � .'wr�_ .' >•n,..wrn�,..o- aw
i � w •a •ar .y « raa«ar.arre"a" car , - _ .— � O
w •r are mn a onma
•wre�e M IM a 6v Sa« sn rru.rcorao"o�m•vwza . ca wr,ersar Faslenig Obpct Snap onto the UFO to hln Borg ov x las to rails while Borg and alted,XR Rats '1 1
w•.«a s.+on >t k.v„.vsesic°mwa n.=c .u.rgea<•omat.+•mrw raxr m^ears '"` band modals id rarls. intoabonded—.damp stayxg cvnlpb
/mlerbY..lo tely hrdtlert to roof albcMMts. /`� 00
e�RWlt. v w ro -F.-My assembled hee bled b d Bond modu s les M rei e �U—sal end--dernp T a Sqare®u11 opto- cc Q L oar•�weeantawKrr Earre.aeww•rr+°• e.y 0 n Qy
single.un verse)we Sietl to ma ilb tcn rtldd -Tool-less msblWnq •Nut uses 7/1k'sockel V J IL
-•-s-tiwr - w'•1i°" r _ Char and black frvah •Ckar and M}r harsh Fuay assembled Assenlded and MArcated v O
Cr•r-wa - - oaw"n•au.racwa FLehFoot2^ Fbehyue^ KnockaA Tik AN Tile Nook
p _ \ 0 00
o
Kati.. can <« e.e.rcrr.rv� ..r^ p,x; qn f w..r.r,ay w.w r.e..aeai s.•sw,o oo.snwa° ?. l \ �.. ,.;. �/ O Z
r•.w.e..�.•rr.w._ can n« ..iris r..>< °aria «a err. 11►r s
MierOj•a••�•`c• 'n w,ry f oc ryraasrcrc. ns Flesh and mount XR Raa� Flash and nx)unt—i, R ��-
r°r•~epert6s b Synem Wsipn ryxea.ro..a=r�.aw-a ar Replace ales and ensure Mount M 9b rmla"a
_ _ wth.wcemr waleryroonng. scan.or lurX.tpn boxes. sup«ar weteryoof�. simper adFlatrMa hoot 1111/
"•+�°��New mt,ma.errron Cap •Tvstoneapasseaaman •Fiat S.bwnk arks i4aPaaw,� Mixt trwt � •twistWIW-on Cd '
tr.an nramwrarm«ea n.r,y.e.,.r ' amawrn.•w.r.,r« p •wake to sal S.i w ales
n'+y mabr,•«rmoe rrir�a.e <x.' ...ar..ra.m"r.aS. ..°°o.r�ar-°I Ala bind sac Lean �settees a'N l-Icondat �Srrgle-kg universal base .O arotauatw^ ♦� •.e ''�
•t�1�M' Itlor°arM CerEitkalM Wsely.w.q __ -__...__- ♦ �O��
eSl-r»mmaT-ri:am(1Y1
---- J� f�•.�'��
Caslgn AesiMant ;I.: Endorsee by FL 8lillrq CalienYYm : C-' • i
e J S Y Y ,y... Form Florida
ri a od,c,appee el for =�. :w
Mw•••nru.naman y� Go from�sh W«JF«ties l. =•%
ergmeer ystemI., to receive Fkxitla Produ 2 appgy 6r
e,or mS2017 Fbrbe.._�+swr•.�.ca a.,.r. �.rrr...T..�rwr.��r.warr.,a--w.rr•ea.r.ir.aw��rw.,ram•
[ro..•.�wd..�w.- au.raouara.rmaW.a�^m..^w�rrrmm�r..r.m-a _--� i ;'n�, ��.� — — BM-din—g code
ode ooapam
�
� oLaem Mry dt.H•twioart w :e oma
ocells a o• sc-
�.
o.i-=aE».iamt=.,e, •.
I,
Solar Installation Electric Diagram
Modules
22 Qpeak Duo Blk ML-G10+410 Roof Mounted PV Array 9.02 kW DC
2 Strings of 11 Microinverters—line Side Tap Existing utility
revenue meter
(new net meter)
Microinverters
22 Enphase Energy three(3)#6 THHN conductors
IQ8M-72-2-US and#6 ground in 1"PVC(inside)
2 sets of 2#12 conductors
(microinvgrter cable)
and#6 AWG GEC/EGC
Existing Main
Junction Box 20A
40A Distribution
F40A
Panel
20A
Interior AC Fused 200A Main Breaker
Service Rated
Disconnect Switch N G
60A,240VAC
N G Four(4)#10 THWN-2 conductors n _ n N G
and#6 ground in 1"PVC(outside) I�I�I_ ❑�—❑ #6 GEC
Dedicated PV Sys te
AC Combiner Panel
60A,240VAC
Qcell Qpeak Duo Blk ML-G10+410 Specs
MPP Voltage:37.64V
Property Owner ,�tit��p
MPP Current: 10.89A
QC9 PA
Open Circuit Voltage:45.37V Name: Christina Sun .�
Short Circuit Current: 11.20A 615 East Gillette Drive * FNorthport,
Company
Module Efficiency:20.9% East Marion, NY 11939 ' �. ar
Account#-9674059403 4
QZ t 33 p
Maximum System Voltage: 1000V lF � alonga Road
Maximum Series Fuse Rating:20A Meter#- 98385565 NY 11768