HomeMy WebLinkAbout52147-Z TOWN OF SOUTHOLD
BUILDING DEPARTMENT
TOWN CLERK'S OFFICE
SOUTHOLD, NY
BUILDING PERMIT
(THIS PERMIT MUST BE KEPT ON THE PREMISES
WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS
UNTIL FULL COMPLETION OF THE WORK AUTHORIZED)
Permit#: 52147 Date: 08/06/2025
Permission is hereby granted to:
Jennifer E Maye
606 Riverside Rd
North Palm Beach, FL 33408
To:
construct a single-family dwelling as applied for per SCHD approval.
Premises Located at:
875 Fleetwood Rd, Cutchogue, NY 11935
SCTM# 137.-5-7
Pursuant to application dated 05/02/2025 and approved by the Building Inspector.
To expire on 08/06/2027.
Contractors:
Required Inspections:
Fees:
Single Family Dwelling-NEW $2,243.50
CO Single Family Dwelling-New $100.00
Total S2,343.50
�wgInspector�
TOWN OF SOUTHOLD—BUILDING DEPARTMENT
Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959
Telephone(631) 765-1802 Fax(631) 765-9502 hIt :dw� . osalholdowiu .�08
,.�ere.eat
Date Received
M
For Office Use Only I j
PERMIT NO. )4_1Building Inspector;
Applications and forms must be filled out in their entirety.Incomplete Building Department
applications will not be accepted. Where the Applicant Is not the owner,an Town of Southold
Owner's Authorization form(Page 2)shall be completed.
Date: S,a,a is
OWNER(S)OF PROPERTY:
Name:Fred Smith and Christine Peddy lic—TM #1000-137.00-05.00-007.00
Project Address:875 Fleetwood Road, Cutchogue, NY 11935
Phone#:917.841.3098 1Email:fred.smith@nmrk.com
Mailing Address:20 Beekman PI, New York, NY 10022 Apt. PHC
CONTACT PERSON:
Name:Christine Peddy
Mailing Address:445 Pequash Ave, Cutchogue, NY 11935
Phone#:646-706-6113 Email:christinelpeddy@gmail.com
DESIGN PROFESSIONAL INFORMATION:
Name:Vincent Albert, RA
Mailing Address:106 New Hampshire Avenue, Massapequa, NY 11758
Phone#:516.241.9146 Email:Vincent@VMAarchitect.com
CONTRACTOR INFORMATION:
Name: rpv��F
Mailing Address: ` %\
1 S 0 �c�
Phone#: (,��jL,aq� .��.2.a Email:
DESCRIPTION OF PROPOSED CONSTRUCTION
ANew Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project:
❑Other $400,000
Will the lot be re-graded? MYes ONO Will excess fill be removed from premises? *Yes El No
1
PROPERTY INFORMATION
Existing use of property:Vacant Land Intended use of property:One Family Residence
Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to
R-40 this property? ❑Yes ONo IF YES, PROVIDE A COPY.
0 Check Box After Readinp: The owner/contractor/design professional is responsible for all drainage and storm water issues provided by
Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the Issuance of a Building Permit pursuant to the Building Zone
Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings,
additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code,
housing code and regulations and to admit authorized inspectors on premises and In building(s)for necessary Inspections.False statements made herein are
punishable as a Class A misdemeanor pursuant to Section 210AS of the New York State Penal Law.
Application Submitted (print name):Vincent Albert BAuthorized Agent ❑Owner
Signature of Applicant: (����►�► V Date:
STATE OF NEW YORK)
SS:
COUNTY OF )
Vincent Albert being duly sworn,deposes and says that(s)he is the applicant
(Name of individual signing contract) above named,
(S)he is the Architect of Record
(Contractor,Agent,Corporate Officer, etc.)
of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this
application;that all statements contained in this application are true to the best of his/her knowledge and belief,and
that the work will be performed in the manner set forth in the application file therewith.
Sworn before me this
ayof 20 � ` lti rk
p
� "332 4
nty
Qualified insSSW 2
Commission FOPi
PROPERTY OWNERAAUTHORIZATION_.�..�.
(Where the applicant is not the owner)
Christine Peddy residing at 445 Pequash Ave, Cutchogue, NY 11935
do hereby authorize
Vincent Albert to apply on
my behalf to the Town of Southold Building Department for approval as described herein,
le
own er`s igna J Date
Print Owner's Name
2
MSUAL
BEACON MAC"R"AIR
ALTERNATE SEWAGE DISPOSAL SYSTEM FOR HIGH 124%IQLT OUTLET OO,NTTiOLL(!j BLOWER
' scALID LaAnW of — COMPRESSED
_ YppF,sATE WANE Acnp€1 uNE GROUNDWATER CONDITIONS FOR ONE TO FOUR ( pN-sCT PLa '' AIR LINE TO
W ` E BEDROOM RESIDENCE. R)
i S'V€ .€CL' :.€ATST F` DF'€'3i "F'3P' yRC}?sNG OWTS TO BE.
HARDWIRED
N�NoxN NF1a YYate tines It [need the ` INSULATED
A�Wuss BLOWER
if g Suffolk I•Dun nt. health.?$C`i7�Ce3, GRADE -- ENCLOSURE
O Call 1631)852-5754,48 hours in _
N/ ENNIRRUAYE advance,to scheduleinspection(s), � CONTROL PANEL AND BLOWER DETAIL
PUBLIC WA,M _--
HOUSE
fr
s �PR .-, �� _-
o—0— .!!rr__ s� R1NE I,
EIZCTRIC SEPN6 yi } �+
LONN—
`4.+ P
eto e
1 A
,Es—
a w }gZA¢3°34
83 - ♦ -
EAAoa a --- � .aa-:� ERG€>•�;A Yea L'£a
'$1 S
I Ea�:m 'PiE.la1+18FTrp NULFUCs
(ow°) r mmTl Kj I'' YUT,.,I_ II --.� <T ,pe.rHE SEPrc„lr sxo�lo ENNN..eMpp�ESNc>sNL,Ps w,wpEeE FF=7MnwNl FxrExnxe,wmNCN rNaFwvo>mvro>wwr>uwurw
_22 ru
cpN HEaoii°u e,`c EME
R E CAx
rIEN1 lr Fm 5USEFgcR0SS—EF IIIESrE,wN,NE.— INo TN,r°up 1-1—N°s L.Ev>novb,uFAsysocr,w.wm
,1EAEsxuL
ilil „ $ ` LlEc,wcAL
"p. ry -PRCPpSFD UNDFAQ,WNO sAgo,c,Fqo pv
s SACKE L�MArEq AL sNAll BE ccAgsE sAno nnp LpAS EI
SLnBs$NALI BF n M N MUM TL eslox'cgnoE BFlax cvaoE
NTNr,E a SNL TD co RE,E col EN SHALL SE IErx EEI a Ar:p Tz PROPOSED INVERTS
eLONTR ANp LxlNma RE A N N NUM of S I IT ABaI E H CNEsr glcpgpLp AND ELEVATIONS
N/T.wNN Wfl55 '>% I isNS { "I Se' PANEL LLiCA AWE ur ow ,ou N'� HYDHOACTION.1 A OWTS
' f EiA�NNE
PUBLIC W iw jd z� - y, kJ7 j -- ----. SHALLOW LEACHING
i4UP' LU I - POOL DETAIL �
W .n.."u Ka ,...,,.M,a<a
1 [
BMW �# ] Ex vA-,!ON INSPECTION REQUIRED
ACE RE9 m. (n-1 I '}'® - i SUFFOLK COUNTY DEPARTMENT OF HEALTH SERVICES
B p REE Mpp RpAp FOR SANITARY SY�.
....'A.. ' °"`WAY A.I w Y HEALTH DEPARTMENT ' PERMIT FORAPPROVAL OFCONSTRUCTION FORA
.te° SINGLE FAMILY RESIDENCE ONLY
. r
10
,
ads I rz LlA'I€ 43t5 C3, R-25-0362
€€€ MCop b
N/F PNwb cAL°WELL sZa 4' �"�.
IN, gN
ROBFA or N£LL k a , - �-•.�, €TTR W."M'3-UM _....8�1'T.;t M5
PUBIIc WA MAP
PRmECT.EE EXPIRES THREE YEARS FROM DATE OF APPROVAL
veas N� _, -
VI PLANS APPROVED-7l16/202
SITE PLAN Dzs 6�P ores<o ai s e Pcat o R q ep
m�P,'mx PERMIT EXPIRES-3/13/2028 .: A€«t Sum it c RA e'Yt
LIT"wEA 1um Pr.. .—_,r � ( � e� The€ns!aila^c�aid toN,frzcftc�.of the Sea=ge D vr4sa:System
NO1� slwLunL�,nEMux HOUSE was,e PwgexproRTmpPEpvENnunox PUEegowN FINE SAxosP Use Form WWM-073
PASrbTEM
HYp15—I x.x.mpEb pN—HOUSE 1 .a ppNpM a,gx-NpE
, NEmxBomxcPROPERT ESALLcoxxscreoro Pueuc WnTEq BROWN CUYCH
a IrR—IIl11.WE,ER WATE11-T"'xsEGTSROOF LonaNC MEpuopusnc[DYERS Al11n CNACE —"Axp —�,
wniER IN BROWN LLAY CH @ -
cRNNEY msEN6 sHN1 ee NACCogoANCE YnrH xpxS SirWpnppa FOR APPgoVALUF RAHSAxp CONBTxpCnoN OFSEwA°E T.T
o SPwvL E,S,EMS Fpp swcL'MRTYRESmENCES OA,Ep APNL B NR SECnoNscts.ASEF-EDYLmsHNLBEPRONBEo.
b oWfs S4MLBETALL:FOR WA,ER,WHfNEssI TOANpMNcoxbrtEuaxc AM IEPA TNEIT 1 BY TIE MAxOFAc,uRER •—= .8 -
b ,xEo'MswaTAtIFA SNALL NOLOAv vA OWfs ENSMRSEMEN,FPOM SOFFOLNcoUHry pEPMIMExi of HFALM Aim 6xALL BE Ax "L6�
AurxoRMEp RT TAO ER, s�� ----
,nE Duns wTAlaFAsxALL gsaLSTERTHE ONsnE iR4idENTsysTEMwrtN sussoLx colnm oEPARTMFMOPHEAI,N WATER IN PALE BROWNS- ----.--
aMBSHA WONT PE ANON ru 1 rREW aF,HEPA-1 e.a
.b.-1—N-.1�e IFIED atr .-cs.°€e- awe t et+aa t s.T,c canwrts swu [ BILL OF MATERIALS
G=r�NTa"ELTEMENcouNrEREO Z.i
BEL°WS°pPAce PROPOSED SITE PLAN 8 SANITARY DETAILS
psp swTH N°P°b aPpR
SINGLE LINE DIAGRAM Mr"
1 E bEx
r
I
NOTICE
Icova=AnnwYwavpn vo.xoiiw AmmTvum '
�i �e�ra _ '. r,.wswrocauz.mc,NxoFse.Aceorsrosus•sreM.rm vnc�Aw.rpEsmexcEaunreoww n.zon �s €�1��zlo�—
aesxe 6 r+�se a= va „� ssc,o.s��..>secmm+vr err,oa+ule.wwrosa i,.
$=r U N AN400
A TANK DETAIL
.-.,na ----. � �• a- . ,os. ten€ l or 1
Telephone(631)765-1802
Town Hall Annex
54375 Main Road �`� Fax(631)765-9502
P. O. Box 1179
Southold, NY 11971-0959
�. vW"
Y�
BUILDING DEPARTMENT
NOTICE OF UTILIZATIOROF TRUSS TYPE CONS TRUCTION, PRE-ENGINEERED
WOO!? CONSTRUCTION AND/'OR TIMBER CONSTRUCTION
Date:
Owner:Qt
Location of Property:
r
Please take notice that the (check applicable line):
New commercial or residential structure
Addition to existing commercial or residential structure
Rehabilitation to an existing commercial or residential structure
to be constructed or performed at the subject property reference above will utilize
(check applicable line):
Truss type construction (TT)
Pre-engineered wood construction (PW)
Timber construction (TC)
in the following location(s) (check applicable line):
Floor framing, including girders and beams (F)
Roof framing (R)
Floor and roof framing (FR)
Signature:
Name (person submitting this form):�'�vA
Capacity(check applicable line):
Owner
Owner representative
TrussReg15.docx Effective 1/1/2015
Buildine De artinent Application
AUTHORIZATION
(Where the Applicant is not the Owner)
I, G� ► Nve residing at4tl'S?c Uu PK r
(Prmt property c�wne s name) ( ailing Address)
do hereby authorize
(Agent)
to apply on my behalf to the
Southold Building Department.
5
.2, g,0a5
( wner's Saga�atL(re) .... �— � (Date)
(Print Owner's Nat )
Generated by REScheck-Web Software
Compliance Certificate
Project 875 Fleetwood Road, Cutchogue, NY 11935
Energy Code: 2018 IECC
Location: Cutchogue, New York
Construction Type: Single-family
Project Type: New Construction
Project SubType: None
Conditioned Floor Area: 2,282 ft2
Glazing Area 29%
Climate Zone: 4 (5572 MD)
Permit Date:
Permit Number:
All Electric false
Is Renewable false
Has Charger false
Has Battery: false
Has Heat Pump: false
Construction Site: Owner/Agent: Designer/Contractor:
875 Fleetwood Road Vincent Albert
Cutchogue, NY 11935 516-241-9146
Vincent@VMAarchitect.com
Compliance: 3.6%Better Than Code Maximum UA: 412 Your UA: 397 Maximum SHGC„ 0.40 Your SHGC: 0.30
The%Better or worse Than Code Index reflects how close to compliance the house is based on code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home.
Slab-on-grade tradeoffs are no longer consiithered in the UA of,performance ce compliance path in RESchi.miC.lrm Each slab—on—grade
asrwrndly Wn the specified chrnate:zone must mer t the r'rlln1murrri einergy col e irm daboa ,r i,"'t_valrre and depth rerlutrernents,
Asumbfiga
Gross Area Cavity Cont. Prop. Req. Prop. Req.
Perimeter
Ceiling: Flat Ceiling or Scissor Truss 1,237 30.0 0.0 0.035 0.026 43 32
AGW Main: Wood Frame, 16"D.C. 2,285 15.0 4.0 0.057 0.060 94 99
Windows: Vinyl Frame 642 0.300 0.320 193 205
SHGC: 0.30
Above Crawl:All-Wood joist/Truss 191 19.0 0.0 0.047 0.047 9 9
Foundation Walls: Solid Concrete or Masonry
Wall height: 7.8' 1,015 0.0 14.0 0.051 0.059 50 58
Depth below grade: 6.2'
Insulation depth: 7.8'
Windows:Vinyl Frame 28 0.300 0.320 8 9
SHGC:0.30
Project Title: 875 Fleetwood Road, Cutchogue, NY 11935 Report date: 04/18/25
Data filename: Page 1 of10
Compliance Statement. The proposed building design described here is consistent with the building plans specifications, and other
calculations submitted with the permit application.The proposed building has been designed to meet the 2018 IECC requirements in
REScheck Version : REScheck-Web and to comply with the mandatory requirements listed in the REScheck Inspection Checklist.
Gerson Rubio, P.E. 4/22J2025
Name-Title Signature Date
Project Title:
875 Fleetwood Road, Cutchogue, NY 11935 Report date: 04/18/25
Data filename: 2 of10
REScheck ft re Version : REScheck-Web
Inspection Checklist
CNili
Energy Code: 2018 IECC
Requirements: 100.0% were addressed directly in the REScheck software
Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
section Plans Verified Field Verified
# Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions
& Req.ID —_ N�,�..
103.1, Construction drawings and ❑Complies Requirement will be met.
103.2 documentation demonstrate ❑Does Not
[PRl]1 energy code compliance for the ❑Not Observable
building envelope.Thermal
envelope represented on ❑Not Applicable
construction documents.
103.1, ;Construction drawings and Requirement will be met.
103.2, '!documentation demonstrate ❑Does Not
403.7 !energy code compliance for
[PR3]1 lighting and mechanical systems. ❑Not Observable
Systems serving multiple ❑Not Applicable
;dwelling units must demonstrate ,
;compliance with the IECC
;_Commercial Provisions.
IT 302 1, Heatingand cooling equipment is Heating;
Heating. ❑ ®r pties 'Requirement will be met.
403.7 sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not
[PR2]2 on loads calculated per ACCA Cooling. Cooling: ;❑Not Observable
Manual J or other methods Btu/hr Btu/hr
approved by the code official. ❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 ',Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: 875 Fleetwood Road, Cutchogue, NY 11935 Report date: 04/18/25
Data filename: Page 3 of10
Section Plans Verified Field Verified
# Foundation Inspection Value Value Complies? Comments/Assumptions
& Re .ID
402. 1 Conditioned
d basement w llnterior R=� R-^ ...� nD mplies table feEnvel values.
Assemblies
�
o es
1 oes Not
insulation is used,verification "[-]Not Observable "
may need to occur during
Insulation Inspection.Not ❑Not Applicable
required in warm-humid locations x
in Climate Zone 3.
......... ..........
303.2 Conditioned basement wall ❑Complies Requirement will be met.
[FO511 insulation installed per ❑Does Not
t :manufacturer's instructions. ❑Not Observable
❑Not Applicable k
402.21 .i9 Conditioned basement wall ft - � ft �
❑Complies °See the Envelope Assemblies
[FO6] insulation depth of burial or ❑Does Not table for values.
distance from top of wall.
❑Not Observable
❑Not Applicable
�303.2.1 A protective covering is installed ❑Complies ;Exception: Requirement is
[FO11]2 :to protect exposed exterior ❑Does Not not applicable.
insulation and extends a ❑Not Observable
minimum of 6 in.below grade.
❑Not Applicable
403.9 Snow-and ice-melting system ❑Complies Exception: Requirement is
[FO12]2 controls installed. ❑Does Not not applicable.
-]Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 .Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: 875 Fleetwood Road, Cutchogue, NY 11935 Report date: 04/18/25
Data filename: Page 4 of10
Insection Section 9 9 p Plans Verified Field Verified
# Framin / Rou h-in Value Value Complies? Comments/Assumptions
& Req.ID
GlazingU-factor(area-weighted U- _ U- Complies e Envelope Assemblies
402.3.1, average). mmmIT
❑
❑Does Not table
s.
402.3.3,
I❑Not Observable
402.5
402.5 ❑Not Applicable
303.1.3 U-factors of fenestration products ❑Complies Requirement will be met.
[FR4]1 are determined in accordance ❑Does Not
^with the NFRC test procedure or "
,taken from the default table. []Not Observable
❑Not Applicable
402.4.1.1 :Air barrier and thermal barrier ❑Complies ,'Requirement will be met.
[FR23]1 installed per manufacturer's ❑Does Not
j instructions. ❑Not Observable
❑Not Applicable
„"MAN;"„,�w ' f;,,,,,;,�rowMrwmr✓wm mwrimHPrvNN
402.4.3 Fenestration that is not site built "®Complies ,Requirement will be met.
[FR20]1 is listed and labeled as meeting ❑Does Not
AAMA/WDMA/CSA 101/I.S.2/A440
;or has infiltration rates per NFRC ❑Not Observable
"„400 that do not exceed code ❑Not Applicable
l i m its.
402.4.5 IC-rated recessed lighting fixtures ❑Complies ,Requirement will be met,
[FR16]2 sealed at housing/interior finish `❑Does Not
and labeled to indicate 152.0 cfm
,[]Not Observable
leakage at 75 Pa. I
❑Not Applicable
03.3.1 �Supply and return ducts in attics ❑Complies Requirement will be met.
[FR12]1 insulated >= R-8 where duct's ❑Does Not
^>= 3 inches in diameter and >_ ;.' ❑Not Observable
R-6 where < 3 inches.Supply and
return ducts in other portions of ❑Not Applicable
the building insulated >= R-6 for
diameter>= 3 inches and R-4.2
'for< 3 inches in diameter. "
403.3.2 Ducts, air handlers and filter ElComplies ;Requirement will be met.
[FR13]1 boxes are sealed with ❑Does Not
;joints/seams compliant with
International Mechanical Code or -]Not Observable
;I ;
International Residential Code, as ❑Not Applicable
,applicable.
403.3.5 Building cavities are not used as s, ❑Complies Requirement will be met.
[FR15]3 ducts or plenums. ❑Does Not
❑Not Observable
" ❑Not Applicable f
403.4 HVAC piping conveying fluids R- R- ❑Complies Requirement will be met.
R17]2 above 105 °F or chilled fluids ;❑Does Not
below 55 °F are insulated to>_R-
3 I❑Not Observable l
r �'❑Not Applicable
403.4.1 ;Protection of insulation on HVAC ❑Complies ;Requirement will be met.
[FR24]1 ,piping. ❑Does Not
❑Not Observable
❑Not Applicable
403.5.3 Hot water pipes are insulated to R- R-� ❑Complies Requirement will be met.
[FR18]2 >_R-3. ❑Does Not
m ❑Not Observable
❑Not Applicable
403.6 Automatic or gravity dampers are ❑Complies Requirement will be met.
[FR19]2 installed on all outdoor air Does Not
intakes and exhausts.
❑Not Observable
Applicable
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: 875 Fleetwood Road, Cutchogue, NY 11935 Report date: 04/18/25
Data filename: Page 5 of10
Additional Comments/Assumptions:
1 High impact(Tier 1) 2 Medium impact(Tier 2) 3.._
Low Impact(Tree 3)
Project Title: 875 Fleetwood Road, Cutchogue, NY 11935 Report date: 04/18/25
Data filename: Page 6 of10
Section :dens Verified Field insulation Inspection,
Verified
&Re ID
�.. Value Value
comp es7 Comments/Assumptions,
- s labeled ❑0omplies ;Requirement will be m
303.1 'All installed insulation i d
et.
�[IN13,122 :or the installed R-values `❑Does Not
sal: ;provided. ❑NotObservable 8
❑Not Applicable
_ _, ... _.. ....._ ............... .. . _.. _ ., .. ...__ ...... ........
402.1.1, Floor insulation R-value. R- R ❑Complies See the Envelope Assemblies
402.2.6 }❑ Wood ❑ woo d ❑Does Not table for values.
[IN1]1 ❑ Steel ❑ Steel ❑Not Observable
❑Not Applicable
303.2, +Floor insulation installed per ;.❑Complies :Requirement will be met.
402.2.8 manufacturer's instructions and ❑Does Not j
[IN2)1 :in substantial contact with the ❑Not Observable
I�tif underside of the subfloor, or floor
framing cavity insulation is in `❑Not Applicable
contact with the top side of
sheathing,or continuous
insulation is installed on the
underside of floor framing and
extends from the bottom to the
;top of all perimeter floor framing
members.
402.1.1, ;Wall insulation R-value. If this is a R- R- `❑Complies See the Envelope Assemblies
402.2.5, mass wall with at least�/�of the ❑ Wood :❑ Wood ;❑Does Not table for values.
402.2.6 wall insulation on the wall ;❑ Mass ❑ mass ❑Not Observable
[IN3]i exterior,the exterior insulation
� requirement applies(FR10). ❑ Steel ❑ Steel tlNot Applicable
303. maul insulation
n latio manufacturer's installed
instructions. OComplies Requirement will be met.
1 oes Not
,,[-]Not Observable
❑Not Applicable
Additional Comments/Assumptions:
11 High Impact(Tier 1) 2 medium Impact(Tier 2) 3 ILow Impact(Tier 3)
Project Title: 875 Fleetwood Road, Cutchogue, NY 11935 Report date: 04/18/25
Data filename: Page 7 of10
FSecon Plans Verified Field Verified p Final Inspection Provisions ValueCom lies. Comments/Assumptions
.ID _ __
402.1.1, Ceiling insulation R-value. R ❑Com lies 'table
402.2.1, n.�.� Wood ❑ Wood .��_ �� p
e. R- a the Envelope Assemblies
es Not ble for values.
402.2.2, ❑ Steel ❑ Steel ❑Not Observable
402.2.6 ❑Not Applicable
[FI1]
303.1.1.1, (Ceiling insulation installed per ❑Complies Requirement will be met.
303.2 manufacturer's instructions. '❑Does Not
[FI2]1 ;Blown insulation marked every 300 ft2. ❑Not Observable
❑Not Applicable
i402.2.3 Vented attics with air permeable ❑Complies ;Requirement will be met.
[FI22]2 insulation include baffle adjacent '❑Does Not
to soffit and eave vents that
extends over insulation. ❑Not Observable
❑Not Applicable F
402.2.4
�,Attic access hatch and door R- R- �❑� � Complies I Requirement will be met.
[FI3]1 insulation >_R-value of the ❑Does Not
adjacent assembly. ❑Not Observable
j❑Not Applicable
402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50 = ❑Complies ;Requirement will be met.
[FI17]1 ach in Climate Zones 1-2, and EDoes Not
<=3 ach in Climate Zones 3-8.
❑Not Observable
❑Not Applicable
403.3.3 Ducts are pressure tested to cfm/100 cfm/100 ,❑Complies ,Requirement will be met.
[FI27]1 determine air leakage with ft2 j ft2 ❑Does Not
either: Rough-in test:Total ❑Not Observable '
leakage measured with a i
i pressure differential of 0.1 inch ❑Not Applicable
w.g.across the system including
the manufacturer's air handler
enclosure if installed at time of
test. Postconstruction test:Total
leakage measured with a
pressure differential of 0.1 inch
w.g.across the entire system
including the manufacturer's air
handler enclosure. = _
403.3.4 Duct tightness test result of<=4 cfm/100 cfm/100 ,❑Complies Requirement will be met.
[FI4]1 cfm/100 ft2 across the system or ft2 ft2 ❑Does Not
<=3 cfm/100 ft2 without air
handler @ 25 Pa.For rough-in �❑Not Observable
tests,verification may need to ❑Not Applicable
;occur during Framing Inspection. ;
403.3.2.1 ;Air handler leakage designated ❑Complies ;Requirement will be met.
[FI24]1 by manufacturer at<=2%of `❑Does Not
design air flow.
-]Not Observable
❑Not Applicable
403.1.1 Programmable thermostats ❑Complies 4 Requirement will be met,
[FI9]2 installed for control of primary '❑Does Not
heating and cooling systems and r "
initially set by manufacturer to I❑Not Observable
code specifications. " ❑Not Applicable
_m,.
403.1.2 Heat pump thermostat installed ❑Complies Exception. Requirement is
[FI10]2 on heat pumps. "[]Does Not not applicable.
❑Not Observable
❑Not Applicable j
403.5 1 Circulating service hot water ❑Complles ,Requirement will be met.
[FI11]2 systems have automatic or ❑Does Not
accessible manual controls.
❑Not Observable
❑Not Applicable
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: 875 Fleetwood Road, Cutchogue, NY 11935 Report date: 04/18/25
Data filename: Page 8 of10
Section Plans Verified Field Verified
# Final Inspection Provisions Value Value Complies? Comments/Assumptions
4012 6 1 All a fans not art l l i s tested and
OComplies Requirement will be met.
y
p listed ❑Does Not
HVAC equipment meet efficacy
'and air flow limits per Table -]Not Observable
R403.6.1. ❑Not Applicable
1403.2 Hot water boilers supplying heat ❑Complies rRequirement will be met.
[FI26]2 through one-or two-pipe heating "" `i❑Does Not
systems have outdoor setback
control to lower boiler water ❑Not Observable
temperature based on outdoor ❑Not Applicable
,temperature.
- 5.1.1 Heated water circulation systems ; „❑Complies Requirement will be met.
![F128]2 have a circulation pump.The ❑Does Not
system return pipe is a dedicated ❑Not Observable
return pipe or a cold water supply;
pipe.Gravity and thermos- %❑Not Applicable
syphon circulation systems are
not present. Controls for
circulating hot water system
pumps um s start the pump 9
with signal
for hot water demand within the
occupancy.Controls
automatically P turn off the pump
when water is in circulation loop
is at set-point temperature and
no demand for hot water exists.
403.5.1.2 Electric heat trace systems ❑Complies Exception: Requirement is
[FI29]2 comply with IEEE 515.1 or UL ❑Does Not not applicable.
515.Controls automatically ❑Not Observable
adjust the energy input to the
heat tracing to maintain the "[]Not Applicable j
desired water temperature in the
piping.
403.5.2 Demand recirculation water ❑Complies !Exception: Requirement is
[F130]2 systems have controls that ❑Does Not not applicable.
manage operation of the pump
and limit the temperature of the ❑Not Observable
'water entering the cold water ❑Not Applicable
piping to<= 104°F.
403.5.4 Drain water heat recovery units ,❑Complies Exception: Requirement is
[FI31]2 "tested in accordance with CSA " ❑Does Not not applicable.
B55.1.Potable water-side
pressure loss of drain water heat []Not Observable
„ �
recovery units < 3 psi for ❑Not Applicable
individual units connected to one
or two showers. Potable water-
side pressure loss of drain water "
heat recovery units < 2 psi for
individual units connected to
three or more showers.
404.1 i90%or more of permanent ❑Complies Requirement will be met.
[FI6]1 fixtures have high efficacy lamps ❑Does Not
❑Not Observable
ONot Applicable
404.1.1 Fuel gas lighting systems have i "" ❑Complies Exception: Requirement is
[FI23]3 no continuous pilot light. ❑Does Not not applicable.
6 ❑Not Observable
❑Not Applicable
401.3 Compliance certificate posted. ❑Complies Requirement will be met.
[FI7]2 ❑Does Not
❑Not Observable Id
❑Not Applicable
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 'Low Impact(Tier 3)
Project Title: 875 Fleetwood Road, Cutchogue, NY 11935 Report date: 04/18/25
Data filename: Page 9 of10
Section Plans Verified Field','I�/erifted
Final Inspection Pro vlslons value Vaine Complies? LCOI
ments/Alssumptlons
Re ID .. .....
03,3 . Manufacturer manua
ls
� alsfor ®Complies ;Requirement will be met.
(i«I18P mechanical and water heating ®Does Not
systems have been provided.
,E]Not observable
Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) ow Impact(bier 3)
Project Title: 875 Fleetwood Road, Cutchogue, NY 11935 Report date: 04/18/25
Data filename: Page 10 of10
CertificateC 2018 I'ECC Energy
Efficiency
�(j
® Y
Above-Grade Wall 19.00
Below-Grade Wall 14.00
Floor 19.00
Ceiling / Roof 30.00
Ductwork (unconditioned spaces):
MOEN=
Window 0.30 0.30
Door
Y Y Y Y Y Y -
Heating System.,
Cooling System:
Water Heater.
Name: Date:
Comments