Loading...
HomeMy WebLinkAbout49256-Z o�*of souryo� Town of Southold * * P.O. Box 1179 �0 53095 Main Rd Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 46155 Date: 05/09/2025 THIS CERTIFIES that the building AS BUILT ALTERATION Location of Property: 450 Stirling Woods Ln Southold, NY 11971 S ec/B lock/Lot: 8 8.-2-15.4 Conforms substantially to the Application for Building Permit heretofore,filed in this office dated: 04/12/2023 Pursuant to which Building Permit No. 49256 and dated: 05/16/2023 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: "As built" finished basement to an existing single-family dwelling as applied for. The certificate is issued to: Gabriel Menendez,.Emily Medina Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: 49256 6/9/2023 PLUMBERS CERTIFICATION: Au o ' ed Signature TOWN OF SOUTHOLD 411 BUILDING DEPARTMENT ti z TOWN CLERK'S OFFICE "oy • o�� SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 49256 Date: 5/16/2023 Permission is hereby.granted to: Menendez, Gabriel 585 10th St Brooklyn, NY 11215 To: legalize "as built" finished basement to existing single-family dwelling as applied for. Additional certification may be required. At premises located at: 450 Stirling Woods'Ln, Southold SCTM #473889 Sec/Block/Lot# 88.-2-15.4 Pursuant to application dated 4/12/2023 and approved by the Building Inspector. To expire on. 1111412024. Fees: AS BUILT- SINGLE FAMILY ADDITION/ALTERATION $1,117.60 CO-ALTERATION TO DWELLING $50.00 Total: $1,167.60 Building Inspector OE SOUr��l � o Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 �Q sean.devlinl-town.southold.ny.us Southold,NY 11971-0959 QIyCOUff N 'w`� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Gariel Menendez Address: 450 Sterling Woods Ln city,Southold st: NY zip: 11971 Building Permit#: 49256 Section: $$ Block: 2 Lot: 15.4 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: AS BUILT License No: SITE DETAILS Office Use Only Residential X Indoor X Basement X Service Commerical Outdoor 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey X Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt 11 Ceiling Fixtures 3 Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures 15 CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO 1 Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 7 4'LED Exit Fixtures 11 Sump Pump Other Equipment: Notes: " AS BUILT NO VISUAL DEFECTS " Finished Basement Inspector Signature: Date: June 9, 2023 S.Devlin-Cert Electrical Compliance Form OF SOGTy� 5 C) # # TOWN OF SOUTHOLD BUILDING DER . I1 `ycourm��'' "1 � 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: 0(L-7t U oJ U 2 U h m) m2A lJ U DATE Z2- INSPECTOR #�OE SOUTyo# TOWN OF SOUTHOLD BUILDING DEPT. �yCIOU �' 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] ULATION/CAULKING [ ] FRAMING /STRAPPING [ FINAL - [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE /O [ ] RENTAL ?1 4)-V�e RE RKS: Aft vyl�- l DATE , INSPECTOR JUN _q 2023 P t.�"�, \ � >�\ � �.�. . _. ���� 7��t ���2 . ��6 ... . 2 ;. ® son CY ° 10 28 d0® 4 Fu will -- ire a ® d ly ci tag I ; ®a4 iL 01+ Y C�►9 t N --- =v - � aa 0 --- '(a)a-n. 141 d!: _ N --a �a5 Y i i r ». <w y. . \ . . �, : . « � « � w . : . � v ? � ©. : . � � . � «. , , »� .�«< , , z2«»�, :» . . �> .«.<� . . . , . � . . < : »«« �.a: « }:<��§��3 . :»a2 : � . y��/!�: y��/\�\ d± �p,y��. \��\ � »� �. � r�«w a az� = ���>��«© ���`���������` ��+� © d\\�\��/2dj . 9*22±» ~� ���\:` �/ �;\« \\�>���\���y����a » � ^\ �^^ � . , �: . , � � as >�y m. . � © � : :w. . x,m » m��®���«. . 2 . > � . » � \\ : . � . �� : :d» : .y\ \ �%\ . . �,�� ._� � ! :.0 s � x i + �� � 4 � o -, r u-� s„� ,�-� ., ,� �� ' � 'y j ' �I !� t i .� ;, '�, `� . �: . � (� � ,7 .� , � ;7 y '� i r �. �. � > r r d � 'fir f °, .. f '� 4���` .,. ,� �, .. . _ � " i FIELD INSPECTION REPORT DATE COMMENTS b FOUNDATION (1ST) N -------------------------------------- FOUNDATION (2ND) r z 0 ROUGH FRAMING& PLUMBING O� kA r INSULATION PER N.Y. y STATE ENERGY CODE lu FINAL ADDITIONAL COMMENTS I 2�3 a�al /� •u c) -9kCO- -ekc. e c, o4 5147 S Z m k O z - x v b Gy TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O.Box 1179 Southold,NY 11971-0959, Telephone(631) 765-1802 Fax (631)765-9502 hftps://www.southoldtownny.gov Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only PERMIT NO. Building Inspector: APR 12 2023 Applications and.forms must be filled out in their entirety Incomplete' 3UILDIIV(a L) I'7. applications will not be accepted. Where`the Applicant is not,th6 owner,an T®I�]�J®FSOi7T ®LD .Owner's Authorization.form(Page 2)shall be,completed Date: Febrary 13, 2023 OWNERS)OF PROPERTY: Name: Emily Medina, Gabriel,Menendez SCTM#1000-088-02-15.4_ Project Address: 450 Sterling Woods Lane,,Southold, NY 11971 Phone#: 646-896-4930 __._.._.....__................__..__ .Email medina.emily@gmail.com Mailing Address: 450 Sterling Woods Lane, Southold, NY 11971 CONTACT PERSON: Name: Emily Medina __- Mailing address: 450 Sterling Woods Lane, Southold,_NY 11971 Phone#: 646-896-4930 _ _..___..._.... .___. _Email: medina.emily@gmail,com DESIGN PROFESSIONAL INFORMATION:.. Name: not applicable Mailing Address: Phone#: Email: __. .._ CONTRACTOR INFORMATION Name: not applicable Mailing Address: Phone DESCRIPTION OF PROPOSED CONSTRUCTION " ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: DOther As-Built existing basement $ n/ap Will the lot be re-graded? ❑Yes ®No Will excess fill be removed from premises? ❑Yes ONo 1 PROPERTY INFORMATION Existing use of property: S.Ingle._,fa_mi.l,y-.--_,. Intended use of property: Sl.ngi-e-famlly_..,-- Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to AC this property? DYes RNo IF YES, PROVIDE A COPY. Li Check Box After Reading: The owner/contractor/design,professionaI is responsible,for all drainage and storm water.issues as provided by Chapter 236 of the'Town Code. APPLICATION IS HEREBYWADE,to,the Building Department for the Issuance of a Building Permit pursuant to the Building Zone ordinance of the Town of Southold,Suffolk,County,New York and,othei applicable Laws,.Ordinances or Regulations,for the construction ofbuildings, additions,alterations or for removal or demolition as herein described:The applicant agrees to comply with all applicable laws,ordinances,.building code, housing code and,regulations and to.admit authorized inspectors on;premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210:45 of the New,York State Penal Law. , Application Submitted By(print name):G a b ri e I Menendez ❑Authorized Agent. B Owner Signature of Applicant: Date: ( Z, STATE OF NEW YORK) CAROLINEMMACARTHUR SS: Notary public-State of New York NO.01MA6384635 COUNTY OF SU�a+—�C ) Qualified in Suffolk County My Commission Expires Dec 17,2026 �.� tg)21 EL MCNC/V P6 being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this 2 day of 14P(24 ,20_0 Notary Public PROPERTY OWNER AUTHORIZATION (Where the applicant is not the owner) I, residing at do hereby authorize to apply on my behalf to the Town of Southold Building Department for approval as described herein. Owner's Signature Date Print Owner's Name 2 g11ff01� BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD y = Town Hall Annex - 54375 Main Road - PO Bo'x�1179 o _ Southold, New York 11971-0959 -*A 4� ' Telephone (631) 765-1802 - FAX (631) 765-9502 1 ' roaerr(cDsoutholdtownnv.aov - seandO-southoldtownnv.aov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: N/A Company Name: N/A Electrician's Name: License No.: Elec. email: Elec. Phone No: ❑I request an email copy of Certificate of Compliance Elec. Address.: JOB SITE INFORMATION (All Information Required) Name: Gabriel Menendez and Emily Medina Address: 450 Stirling Woods Ln Cross Street: Main Bayview Rd. Phone No.: (646) 896-4930 Bldg.Permit#: N/A email: medina.emily@gmail.com Tax Map District: 1000 Section:88. Block: 2 Lot: 15.4 BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): A portion of the basement was finished with drywall to create a recreation space.Electrical work included lights and electrical outlets The rest of the basement remains unfinished per the original building plans. T,hh&W ft listed is for fini hed portion Square Footage: 1804 Circle All That Apply: Is job ready for inspection?: R1 YES❑ NO ❑Rough In Final Do you need a Temp Certificate?: ❑ YES [-V� NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service[-]Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals M 1 2 D H Frame Pole Work done on Service? MY N Additional Information: PAYMENT DUE WITH APPLICATION re- c4. /-64Sq BUILDING DEPARTMENT- Electrical Inspector �o Gyp TOWN OF SOUTHOLD Town Hall Annex - 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 rogerr&southoldtownny.gov - seand ansoutholdtownnv.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: N/A Company Name: N/A Electrician's Name: License No.: Elec. email: Elec. Phone No: ❑I request an email copy of Certificate of Compliance Elec. Address.: JOB SITE INFORMATION (All Information Required) Name: Gabriel Menendez and Emily Medina Address: 450 Stirling Woods Ln Cross Street: Main Bayview Rd. Phone No.: (646) 896-4930 Bldg.Permit#: N/A yq 2SG email: medina.emily@gmail.com Tax Map District: - 1000 Section:88. Block: 2 Lot: 15.4 BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): A portion of the basement was finished with drywall to create a recreation space.Electrical work included lights and electrical outlets The rest of the basement remains unfinished per the original building plans.The so ft listed is for finishedoortion Square Footage: 1804 Circle All That Apply: Is job ready for inspection?: YES ❑ NO —]Rough In ❑✓ Final Do you need a Temp Certificate?: ❑ YES 0 NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service[]Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 0 1 2 D H Frame F1 Pole Work done on Service? Y FIN Additional Information: PAYMENT DUE WITH APPLICATION t PERMIT 9 Address: Switchesk-" Outlets G FI's Surface I Sconces f' H H's I UC Lts Fans Fridge HW Exhaust Oven W/D 1 Smokes DW Mini Carbon Micro Generator ombo '� Cooktop :Transfer �\C ` AH Hood Service Amps Have Usec >pecial: :omments -- (.� to V MeAzodiff ?, February 10, 2023 To Whom It May Concern, Enclosed please find a Building Permit application for 450 Sterling Woods Rd. Please file this application with the As-Built basement plan's that were submitted by AMP Architecture on 2/2. Thank you, Emily Medina (SD ay- Page I of 2 SURVEY OF PROPERTY SITUATE CUTCHOGUE TOWN OF SOUTHOLD SUFFOLK COUNTY, NEW YORK S.C. TAX No. 1000- 104-05-22 SCALE 1 "=209 MARCH 28, 2017 JULY 5, 2018 ADD SPOT GRADES & FLOOD ZONES OCTOBER 1, 2018 UPDATE SURVEY ¢ s . AREA = 24,542 sq. ft. 0.563 ac. 8 e' CERTIFIED TO: Prat�e 8`acK GURe ,GE "N QQ W ". ° CARLOS SAAVEDRA J NICOLE ECKSTROM U*) 00 •. PRO REPUBLIC NATIONAL TITLE AGENCY, LLC ` 5 ' FIDELITY NATIONAL TITLE INSURANCE COMPANY `n 1� MERS (MORTGAGE ELECTRONIC REGISTRATION SYSTEMS Inc.), SOLEY AS NOMINEE FOR TD BANK, N.A. N/�/LORENZO NOTES: NTxONY DE (n 1. ELEVATIONS ARE REFERENCED TO N.A.V.D. 1988 DATUM ! EXISTING ELEVATIONS ARE SHOWN THUS: 5-4 A • •: , D . � F.FL. — FIRST FLOOR ��`� ? s• '• . 2. FLOOD ZONE INFORMATION TAKEN FROM: 0 � �` • D• D e �> FLOOD INSURANCE RATE MAP No. 36103C0164 H �g e�ocK G�v ° ' ° • ZONE AE: BASE FLOOD ELEVATIONS DETERMINED \ cONc• a:. e•. ° (n ZONE X: AREAS OF 0.2% ANNUAL CHANCE FLOOD; AREAS OF 1% ANNUAL CHANCE FLOOD D ° • , ; T WITH AVERAGE DEPTH OF LESS THAN 1 FOOT OR WITH DRAINAGE AREAS LESS THAN o. . ' �" ; D°;: r 1 SQUARE MILE; AND AREAS PROTECTED BY LEVEES FROM 1% ANNUAL CHANCE FLOOD. y ST O WIR m� •D' N. to, ° % ° • • GK G �O NG2� No GPRPG p.p• S' '° �`��h •' �QN,L °. m 4 dll, ga 2 SUN p `r oo cON ROC�P .x �'. , QR�CK�R:. /•. ' POLE 00 ONc F 3Y4 �LOJ. �• g�NOp�� �NtW . U4 •D . 9.4 63�� TAfOMpN• ° D ONc. � SQL 85.7 n cONc• f O�� G s ► 'e • 0 10 �A p e: • �PHPI Z gi I GN�MNEI -ZLQ N IN f C O;0 F•� 1 .+ Z J O tU L O� J.m i< ?,ter x p01 ^ N � N. /E�$$tiEVIN XC NE�Oi W NEOGE O�CA 120, ar OE ! + & 17� S'IC& � rf L PREPARED IN ACCORDANCE WITH THE MINIMUM V STANDARDS FOR TITLE SURVEYS AS ESTABLISHED BY THE ONCE !N FOR U SUCH USE BYN THE PNEW VYORK STATED AND E ADOPTED TITLE ASSOCIATION. j 1 CO FP PE 6g°2� JO N.Y.S. Lic. No. 50467 UNAUTHORIZED ALTERATION OR ADDITION TO THIS SURVEY IS A VIOLATION OF SECTION 7209 OF THE NEW YORK STATE EDUCATION LAW. COPIES OF THIS SURVEY MAP NOT BEARING Nathan Taft Corwin III THE LAND SURVEYOR'S INKED SEAL OR a n d S u r v e y o r • EMBOSSED SEAL SHALL NOT BE CONSIDERED TO BE A VALID TRUE COPY. CERTIFICATIONS INDICATED HEREON SHALL RUN ONLY TO THE PERSON FOR WHOM THE SURVEY IS PREPARED, AND ON HIS BEHALF TO THE Successor To: Stanley J. Isaksen, Jr. L.S. TITLE COMPANY, GOVERNMENTAL AGENCY AND Joseph A. In a no L.S. LENDING INSTITUTION LISTED HEREON, AND P 9 9 TO THE ASSIGNEES OF THE LENDING INSTI— TUTION. Title Surveys — Subdivisions — Site Plans — Construction Layout CERTIFICATIONS ARE NOT TRANSFERABLE. Ys Y PHONE (631)727-2090 Fax (631)727-1727 THE EXISTENCE OF RIGHTS OF WAY OFFICES LOCATED AT MAILING ADDRESS AND/OR EASEMENTS OF RECORD, IF 1586 Main Road P.O. Box 16 ANY, NOT SHOWN ARE NOT GUARANTEED. Jamesport, New York 11947 Jamesport, New York 11947 38-266 IT — — EXISTING F 7— REMOVE EXISTING BRICK REMOVE EXISTING BIL CHIMNEY. NEW INFILL FRAMING TO MATCH MATCH EXISTY1NG V30 '| | |' / ' �sMOvc ' — — — TEMP ADDITION. RELOCATE . . . ' x Ldm�,/ E OF EXISTING WALL uJ NEW INFILL FRAMING TO MATCH AATCH EXISTING COMPLY WITH ALL CODES OF 191-91, NEW YORK STATE & TOWN CODES 7LOOR FRAMING ITIONS OF AS REQUIRED ANDLOND _ . In LINE OF FLOOR ABOVE z Ld 9. POST TO NEW FOOTING 24"X24"X12" POURED CONCRETE 2 STAIR WORK SECTION 61 c. K"_� ';51 'I � G 1':L",')LDER USED IN WATER CANNOT 2 _­GRAYWL PACR; C SS SMOKE ALARMS LOCATED AS REQUIRED FOR NEW DWELLINGS; EAZEED 2110 OF 1% L EA D. SMOKE '0 Ld —DETECTOR THE SMOKE ALARMS SHALL BE INTERCONNECTED AND HARD WIRED. I t—LINE OF EXISTING WALL TO BE REMOVED SM OKE ER RT CA 9. POST To NEW /OCATIEC SS A M I L Y CARBON MONOXIDE ALARMS SHALL BE PROVIDED AS REQUIRED SMOKE DE TECTIR) I SMOKE ELECTRIC PANEL LINE OF EXISTING WALL TO REMAIN r LINE OF NEW WALL r to.-0 Z m - - - - - - - LINE OF EXISTING ROOF BELOW Ln LINE OF WALL BELOW ui 0 SCALE: 1/4" 1'-0" EXISTING DOOR TO BE REMOVED u (:) U) W u L REMOVE EXISTING BOW AS SHOWN. Qf REMOVE EXISTING BRICK < CHIMNEY. NEW INFILL IrTm a, FRAMING TO MATCH III LLJ F- Q < U.1 �>! ED > < < c) 0 EXISTING < 0� OPEN TO 4'-2" KNEE WALL EXISTING ROOF BELOW Ln ,I'VENT BELOW, 1HRU ROOF OPEN RAIL LOFT MOKE LAV LAV W. fE�Me TV I rTUB LIN 3' 2 1 CLOS ar es omas r Ly Y z cn (n L -T x KING 0 XIf SMOKE FRESH AIR INLET DETECTOR IVY rTml FIRST FLOOR 15'-4" FLAT ROOF BELOW CONNECT TO APPROVED AS PER N.Y.S. CODE 3046 3046 30,t6 F.A.I. & SANITARY SYSTEM REMOVE AID REPLACE CORMER EGRESS EGRESS EGRESS PLANS PLUMBING RISER DIAGRAM EXISTING DORMER SCALE: N.T.S DATE: 12/21/18 PROJECT No. CHK BY. THESE DRAWINGS AND ACCOMPANYING SPECIFICATIONS, AS INSTRUMENTS OF SERVICE, ARE THE EXCLUSIVE PROPERTY OF THE ARCHITECT AND TF-IR USE AND PUBLICATION SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY WERE PREPARED. REUSE, REPRODUCTION OR PUBLICATION BY ANY METHOD, IN WI-CLE OR IN PART, IS PROHIBITED EXCEPTBY WRITTEN PERMISSION FROM THE ARCHITECT. TITLE TO THESE PLANS SHALL REMAIN WITH THE ARCHITECT,VISUAL CONTACT WITH THII-M SHALL CONSTITUTE PRIMA FACIE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. ' / ' �� + ARCH ITECT r REVISIONS D E S C R I P T ION EXISTING ROOF TO REMAIN REMOVE EXISI NG AWNING WINDOW. NEW WINDOWS 3 46 I I 3 46 I I 3 46 EXISi1NGSiDM c cH — — — — — — EXISTING ROOF TO REMOVE EXISTING BRICK REMAIN CHIMNEY. MATCH FASCIA 2'-6" EXISTING FLAT ROOF TO 3'-5" REMAIN EXISTING SIDING TO 11 3 46 30 6 REMAIN PATCH AS 3 46 MO6 REMOVE E STING DH EXI ING EXI ING EXI ING EXI NG fP3550 REQUIRED AROUND NEW WINDOW. N W WINDOWS PICTURE WINDOWS AS SHOWN MATCH 3 2 30 2 REMOVE EXIS NG BOW r W 68 FW 68 CW15 EXISTING S DING. WINDOW. NEW WINDOWS AS SHOWN L I I.. GLASS w PROPOSED PROPOSED C) R E A R E L E V A T 1 0 N F R O N T E L E V A T 1 0 N z SCALE: 1/4" = 1 '-0" SCALE: 1/4 = V-0 ' W UJ O — u BILCO O I z w U 0 r.� I - rlrll Q Q LLJ O � Q � 0 Q 10'-2" 13'-8" ct, �. o ® LLJ F— OPEN TO 4'-2" KNEE WALL L I V I N G K I T C H E N z fn Q BELOW DINING _ ROOM R 0 0 M �- LLJ > Q 0 (D 10'-3" = 0 19'-9" � < 0 LINE OF FLOOR ABOVE _ a < HALF WALL F_ L I o - - - - - - - - - - - - - - - - 0 � TTI �, c/) ON UP IJ HALF WALL v Ll LLJ B E D R O O M O ml POURED CONC SLAB FLOOR 0 3 al 25 Y2 BELOW MAIN FLOOR UPPER FAMILY BEDROOM BEDROOM -,,, t) ROOM b 1 2 'ol 0� CRAWL SPACE ACCESS 3'-6" 01 Charles M . Thomas W, 4' 15'-4" 7'-7" FLAT ROOF BELOW _ Z FAMILY a r C h I t e C t 14'-4" 4" 2'-4" 12'-11" JI R 0 0 M PO BOX 877 JAMESPORT, NY 11947 (631) 727-7993 6'-2" PLATE HT N - - - ---- 13'-4" PROJECT ELECTRIC PANEL 23'-11" EXISTING DORMER 30'-11" EXISTING EXISTING FI R S T FLOOR PLAN PLANS SECOND FLOOR PLAN SCALE: 1 /4" = V-0" SCALE: 1/4" = V-0" DATE: 12/121/18 PROJECT No. DRAWING BY. CMT CHK BY. DWG No. 19-1002- 00 2OF2 THESE DRAWINGS AND ACCOMPANYING SPECIFICATIONS, AS INSTRUMENTS OF SERVICE, ARE THE EXCLUSIVE PROPERTY OF THE ARCHITECT AND THEIR USE AND PUBLICATION SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY WERE PREPARED. REUSE, REPRODUCTION OR PUBLICATION BY ANY METHOD, IN WHCE OR IN PART, IS PROHIBITED EXCEPT BY WRITTEN PERMISSION FROM THE ARCHITECT. TITLE TO THESE PLANS SHALL REMAIN WITH THE ARCHITECT.VISUAL CONTACT WITH THEIR SHALL CONSTITUTE PRIMA FACIE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. �K qe ALL FLOOD VENTS PER 'SMART VENT' MODEL # 1540-510 200 SF FLOOD COVERAGE PER VENT p Z z• __ , ' ARCHITECT 8"x16" SMART VENTS SET AT GRADE REVISIONS D E S C R I P T 1 0 N 10/2/19 FEMA COMPLIANCE PLAN EXISTING CMU WALL TO REMAIN 1 3 RESIDENCE LOCATED IN FLOOD ZONE AE 6 (EL. 6) MIN FIRST FLOOR ELEVATION TO BE EL. 8' z z W cn W W --0- - - -8- - - -IE3 - In �';• ;• CRAWL SPACE FILL EXISTING CRAWL SPACE 2" PC SLAB. SET SLAB 12" BELOW SMART VENT MAX. RAISE EXISTING FINISHED FLOOR TO F ELEVATION 8'-0". 2"X10 FJ ® 16" OC N ® 16" OC WITH 3'4" PLYWOOD w R 21 BATT INSULATION EXISTING CMU WALL— TO REMAIN 2 3 EXISTING SLAB TO REMAIN CD w C) _ � � U 8"x16" SMART VENTS EXISTING CMU WALL O / SET AT TO REMAIN GRADE z W U O CD I cr- w o QQ o r L rlr w Hp F 0 U N D A T 1 0 N P L A N z 3: 1 SCALE: 1 /4" = 1'—O" U w > Q = U CD < 0 U QL .................... C/) USE SMART VENT (1540-510) USE SMART VENT (1540-510) WITH 200 SQ FT COVERAGE EACH WITH 200 SQ FT COVERAGE EACH (7 MIN - 11 PROVIDED) 7 MIN (SEE PLAN FOR COUNT (SEE PLAN FOR LOCATION) RAISE EXISTING FINISHED FLOOR TO AND LOCATION) RAISE EXISTING FINISHED FLOOR TO ELEVATION 8'-0". 2"X4" ON EDGE ELEVATION 8'-0". 2"X10 FJ @ 16" OC @ 16" OC WITH 3/4" PLYWOOD @ 16" OC WITH 3/4" PLYWOOD 2" RIGID FOAM INFILL R 21 BATT INSULATION Charles M . Thomas a r c h i t e c t 8"x16" SMART VENTS ^ 8"x16" SMART VENTS PROPOSED PO SOX 877 JAMESPORT, NY 11947 631 727-7993 SET AT EXISTING FJ SET AT GRADE GRADE 12"Xl 0 @16 OC PROJECT EXISTING GRADE N FILL EXISTING CRAWL SPACE EXISTING GRADE EXISTING SLAB TO REMAIN -max 2" PC SLAB. N E SET SLAB 12" BELOW SMART VENT MAX. P L A N S DATE: 10/2/19 PROJECT No. DRAWING BY. CMT 1 DETAIL 1 -3 2 DETAIL 2-3 CHK BY. DWG No. 3 SCALE: 1 /2" = 1'-0" 3 SCALE: 1 /2" = 1'-0" 19-FO-0-31-FO70 3OF3 THESE DRAWINGS AND ACCOMPANYING SPECIFICATIONS, AS INSTRUMENTS OF SERVICE, ARE THE EXCLUSIVE PROPERTY OF THE ARCHITECT AND THEIR USE AND PUBLICATION SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY WERE PREPARED, REUSE, REPRODUCTION OR PUBLICATION BY ANY METHOD, IN WHOLE OR IN PART, IS PROHIBITED EXCEPT BY WRITTEN PERMISSION FROM THE ARCHITECT. TITLE TO THESE PLANS SHALL REMAIN WITH THE ARCHI TECT.VISU AL CONTACT WITH THEM SHALL CONSTITUTE PRIMA FACIE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. Ryall Sheridan Carroll Architects -40-w" March 7th,2025 e�)eV Town of Southold Buildings Department � Town Hall Annex Building ���,. 54375 Route 25 a Southold, NY 11971 `�>oQ O� tS`'J c3 Dear Ms Dwyer: Please find enclosed two copies of the revised house first floor plan at 590 Haywaters Drive in Cutchogue. All of the appliances in the Mechanical+ Laundry room are electric, including the hot water heater.There is no fuel-fired equipment in that room. I have also indicated the operable,egress window in the front bedroom. Sincerely, Niall Carroll RA 3/d-or %_ 174 Fifth Avenue 300 New York, NY 10010 646 809 4343 ryallsheridan.com ECKSTROM ftlEND M NT SAAVEDRA HOUSE 1 ( ( PLANTER 1 r 1 l 590 Haywaters Drive,Cutchogue,NY 11935 1 1 1 REVISION DATE 1 ( REVISED 03.06.2025 1 ( 1 , 1 I P'T�l qR 1 r 131-611 1 �02S 1 ( B'UaFat Town�o So .� ..✓ 1 ' 1" 1 r 1 , 1 ( BEDROOM 1 1 r � 1 � Ir � 3'-6" X 5'-0" CASEMENT WINDOW - 13'-511 14'-5" ENTRY > tO RAMP AND "' < STEPS I CL. co c BEDROOM 2 CL MECHANICAL + LAUNDRY ELECTRIC DOMESTIC ' HOT WATER HEATER CL. J C et c5ol STACKED ELECTRIC AM WASHER + DRYER 10'-4" = ENTRY o BATHROOM 1 N Ln ENTRY 00 CL. OOO RYALL SH ERI DAN ARCHITECTS 174 5TH AVENUE,SUITE 300 NEW YORK,NY 10010 646-809-4343 www.ryallsheridan.com PROJECT#: 2110 DINING KITCHEN LIVING ROOM DRAWN: AB CHECKED: NC C PRINTED: 01.23.2025 E, UP SCALE: AS NOTED AS -BUILT PLAN FIRST FLOOR AS-BUILT PLAN 77-7 , al Lu Uj J C� Occ V) o Z �JE 5 0FE : O >: 0 O O cmz 0 a— 'c� LO C' X (V - AS-SU I LT EX I ST I NC 5ASEMENT PLAN 0 C) m° C 0 0 Cm Lr) Q D 1 CD FROJEG'T DATA : PROJECT / ZONING DATA U 12'-I jy2,F 15F_�2FF EGRESS WELL TAX MAP # 1000-088-02-15.4 ZONING DISTRICT AG LOT AREA 1.0 ACRES —�-- EXIST. EXIST. STORAGE m CofO - DWELLING Z-34'70&; 11/22/2010 / 1 p CLOSET 38.1 S.F. EQ. Ea' 0 in 31.3 S.F. I in GofO - POOL Z-34822; OI/26/2011 T_ a da" ;IN-�IkO414 � _ (I) 3-Ox4-br � DOUBLE-HUNG GofO - POOL CABANA Z-36056; OI/06/2010 EGRE55 WINDOW GofO - SOLAR PANELS #43202; 06/2�i/2022 EXIST. I tu I _ FF :_ :_ FF UNFINISHED 13' 2 13 q 7 3 INSULATION I$ FENESTRATION REOU I REMENTS STORAGE = 261.5 S.F. ' 1— t —1 2Qxb$ EXIST. m 5111 CLO' I I I MECHANICAL r COMPONENT PROPOSED DESIGN CODE PRESCRIPTIVE VALUE 4 COMPLIES ROOMVALUE CITATION (PER 2020 NYSEGGG) 101.3 S.F. EXIST. FINISHED MAX.u-VALUE = os2 AWNING WINDOW 'N Q $ AIR = 025 r5oxr'a RECREATION AREA - 2 xb FENESTRATION U-VALUE AIR LEAKAGE = 0 50 GFM/SF PER RA402.4.3 s TABLE R402J 4 5 CLIMATE ZONE 4 F YES 804 S.F. � MIN.R-VALUE - 15(CAVITY)AT INTERIOR OF WALL(V BASEMENT WALL R-VALUE R=IS GATT INSULATION• INTERIOR PER TABLE R402.1.2-CLIMATE ZONE 4,NOTE(c) YE' HGHT. SOFFIT m ¢ IZ HT. b'q"� to 2 xb m COMPLIANCE STATEMENT: i I _ TO THE BEST OF MY KNOWLEDGE,BELIEF,AND PROFESSIONAL JUDGMENT,THESE PLANS AND 5PEGIFICATION9 ARE IN - COMPLIANCE WITH THE 2020 NYS ENERGY CONSERVATION CONSTRUCTION CODE USIN6 CHAPTER 4[RE]. EXIST. 2¢x6$ L UNFINISHED I fi fi v �t STORAGE I (I) 2'-6"xl'-4" m AWNING WINDOW s �< s r• GLOS EXIST. EXIST. _ ttil kt{e ;�'j t y'•r t �` »` „t :"`�'� 'w _o" .t":.: .s.A. ,;:"� h•' .A ,;, , S.F. 11L UNFINISHED '"CLOSET I .J STORAGE 24 S.F. 212 S.F. 6 �,. .f a �',;`xg°A'�hJ� yaw '. 'c - ':.��i •r ..#iuf l;j'( 'K }r i ' � 19, 7:a ' "`_, y �t� .• I. ��, �"'�. . "•cl � :,. . �, ...• ,Ct' a ay;r"' ., •�('•'•^'' d a A,4` ,� As'+•`,1`°l .sy�:t • 41 LU FORGED AIRUJI r. r* . :.! z EXIST. HEATINO$00OLING ef MEGH. ROOM UNIT O - } `, G;:y';;' 4r 4 `r Q 58 S.F. i �i WA R UP ► ; a:^ r+t yt`s. # #t.`^ r " s., ! . '..!1 p lu TE S PLY • #..` WASTE PIPE 7'-q° _ 'i • w-� fi '`�' �ailxi `' 1 'r, • �.. /jt. y }:•,� -: m m a = � I P'"rrpti r ! f``` f}s°. i �4•, • •""�: (V t t. + .'., f t �}' {J .v �r w •a r `'�' .a bra• , r/MA/ .I�,fi .t�+. tR� Q, �' ��'�• ..���.'fit ''�`` 4` � 'r ,. a ,;.�'r: �' • aj,''' .• =: gyp" - R.!°ylri�'..• • " t•a a i 1 F . W EXIST �f' 'r'�ir s? t r �,• s� • ° '`�'.° t`- m GARAGE SLAB AWNING WINDOW w ° '� ! Ir .,Er ' �4,r ...'�':" i r,1 ly fi �. #' � �� V .. �" �. t .; , �*{ try ' ' � , . ., iw• ."_ .� � 12'-4" 2'-4" : his ,� �-! �, �"�', r. , !ii. PRO ECT• ♦R 4' � ''h' y .' •S{ t':...f , �`� A - ?'9 fir`..• / °."t •1 1•::<r i ,.t �y�,,�_ '�'" r��"J ;i, Y: .., `� { � • ,, a.', a .K,t':. ._�h^per '. -) }+r1"}�„'!A�A � ' {[ .'� ,."'C(G7:_ '• !._ .. ..�fi4 t ....*. •.a.. +...+'' w:..;r :� �"'.',� •M"„r;� M EDI NA II"' if•Lr, f."e J"•,I. I "'" .l+� r 'l'"a°.':,�a ,� - r , y r' .F•_ fyc'�t;. �.C'.'�i ,y'° 'el'a ' �- Rf •,l•• , . "� T art : , ;; .{,,. Lin FINISHED BASEMEN 11.* ' h •.� it'f��. 1� �: .,�' -'+T ' a"a�• , �1 �t' +,,.i. 'y;i'„}''1 .F� .wY, - l;!.` -.�',' ,'Yi' -, ,:/j"r ,:jr`, " {r'S+" .} •�i ,rF. �K Y �1i a ,Y."_7 ♦S'S�e (,, l 'Z.`•-i""-_S ,�j(l'a n' � , ,�' ~ , '� , ��s:p "p:i3'' {�. ,,�.% �•*w�fM�tl ����'��,�'��•.pi5".Y�a •`..' .+J ii 't •t � ���'°, n'+w;t.�.�+ j '�_'4�ss,.`•�:i��� ,.j.�5•.wi- y,7 J ' • .: � . �+. ' ,�; :�;'` ; ` ` �t ,.: P -.t , fi ' 450 STERLING WOODS RD. LOCATION MAP It a, Zil SOUTHOLD, NY 11971 ]�3S SCALE: NTS DRAWING TITLE: DATE: -s B.P.# � . FEE: fL (/PY ._ COMPLY WITH ALL COD ; PROJECT LOCATION &SCOPE NOTIFY QU DIN': - �� jRTMEN_i AT NEW YORK STATE & TOWN 'r�V�jSHED BASEMENT PLAN 765-1802 8 AM T:, 4 1 ;," [-OR THE AS REOUIR.'Er' AND CONDIT. rNS O;= FOLLOWING INSPECTI�0�ti;3: 1. FOUNDATION - Tt�'O REQUIRED __ . "l. L �,•',�..ry FOR POURED CC: :C TE 5'-2Y2" 1O'-1'2" 2. ROUGH - FRAMINCC E PLUM3ING 24'-O" 15'-4" 12'-II" 15-4 4. 3. INSULATION PAGE: JV. �V iliV4!V !f h ,.J 4. FINAL - CONSTF;!711^N MIUST BE COMPLETE � -,�; :' FO. A-100mOO ALL CONSTRUCT'�N SH41-L MEET THE . �,P..�.- • , REQUIREMENTS OF THE CCDES OF NEW YORK STATE. NOT RESPONSIBLE FC`FR DESIGN OR CONSTRUCTION ERRORS. N I SI--I I� �3 S M NT PLAN 1 \111 ATE: 01/25/23 1 OF 1 SCALE: 1/4" = I'-O" OCCUPANCY OR ,. MAY 15 2523 USE IS UNLAWFUL e �t.rao WITHOUT CERTIFICA-. A ; , OF OCCUPANCY Blower door Sv and ductwork �� e'er`' trl� 0 testing required. p+ Must provide Manuals ; D, J and S as per Additional �v�.� 0374o5 �a NYS Energy Code Certification of NEB May Be Required.