Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
51549-Z
of-SO uryo�o Town of Southold f * P.O. Box 1179 r ion 53095 Main Rd UNTf Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 46153 Date: 05/08/2025 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 740 Country Club Dr Cutchogue, NY' 11935 Sec/Block/Lot: 10 9.-3-2.10 Conforms substantially to the Application for Building Permit heretofore,filed in this office dated: 11/13/2024 Pursuant to which Building Permit No. 51549 and dated: 01/14/2025 Was issued, and conforms to all of the requirements of the applicable provisions of the law. ...The occupancy for which this certificate is issued is: Roof-mounted solar panels to existing single-family dwelling as applied for. The certificate is issued to: Jennifer McCarthy ,Patrick Wade Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: 51549 4/11/2025 PLUMBERS CERTIFICATION: AutLrizeV Signature TOWN OF SOUTHOLD BUILDING DEPARTMENT Q TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 51549 Date: 01/14/2025 Permission is hereby granted to: Jennifer McCarthy 740 Country Club Dr Cutchogue, NY 11935 To: install roof-mounted solar panels to existing single-family dwelling as applied for. Premises Located at: 740 Country Club Dr,Cutchogue, NY 11935 SCTM#109.-3-2.10 Pursuant to application dated 11/13/2024 and approved by the Building Inspector. To expire on 01/14/2027. Contractors: Required Inspections: Fees: SOLAR PANELS $100.00 ELECTRIC -Residential $125.00 CO-RESIDENTIAL $100.00 Total S325.00 Building Inspector OF SO(/�yQl h O Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 G • Q Southold,NY 11971-0959 'Q a �y�OUNTV,Oc� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Jennifer McCarthy Address: 740 Country Club Dr City: Cutchogue St: NY Zip: 11935 Building Permit* 51549 Section: 109 Block: 3 Lot: 2.1 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: Long Island Power Solutions License No: 53560ME SITE DETAILS Office Use Only Indoor P-1 Basement F Service F Solar Outdoor W 1 st Floor F Pool F Spa (- Renovation F 2nd Floor F Hot Tub r Generator Survey Attic r Garage Battery Storage r INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph (— Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors. Disconnect Switches 4'LED Exit Fixtures Other Equipment: 7.65kW Roof Nmounted PV Solar Energy System w/ (18)HanwhaQcellQtran425W Modules, IQ Combiner w/ (2)220Breakers & (1)215Breaker, 30A AC Fused Disconnect Notes: Solar Inspector Signature: X Date: April 11, 2025 Sean Devlin Electrical Inspector sean.devlin(�-)town.southold.ny.us 740CountryClubSolar oF soulyO 5 11 7 0 # . TOWN OF SOUTHOLD:BUILDING DEPT.. cou 631-765-1802 INSPECTION ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. ] .FOUNDATION 2ND [ ] INSULATION/.CAULKING ] FRAMING /STRAPPING [ ] FINAL [ ]. .FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION =[ ] !FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [X]. ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: so la r AaAjOho rto4 ow Tit, 1( l0 -ro cove, b o h44' rUoT *1.2 :9 1 -f o t aSA41 oyL `�io co�w�J ��2.4" ho #10 r° C_ DATE INSPECTOR- SOUTyOIo lVOW ( 0 CO # TOWN. F ISO TH LD BUILDING DEFT. O O U O 631-765-1802 INSPECTION [ ] FOUNDATION-1ST/REBAR [ ] ROUGH PLBG.' [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING/STRAPPING [ ] FINAL [ .] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION' [ ] FIRE RESISTANT CONSTRUCTION [ . ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] -CODE VIOLATION [ ] PRE C/O [ ]. RENTAL REMARKS: / No DATE A INSPECTOR OF SOGTyO� TOWN. OF SOUTHOLD BUILDING DEPT. cau 631-765-1802 INSPECTION [ . ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ . ]� SULATION/CAULKING [ ] FRAMING/STRAPPING [ FINAL So [ ] FIREPLACE'& CHIMNEY [ ] FIRE:SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] 'FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) - [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: g l ec,�4 c j c e�f,{; p� �� rns-A- I l C.e.�fi�c�i ov► (-e, � o i h e DATE INSPECTOR = Michael E. Miele, PE Licensed Professional Engineer Licensed In New York, New Jersey, Connecticut&California Q New York License#079676 u New Jersey License#44042 Connecticut License#23158 \ 2p2Gj California License#31508 February 3, 2025 �y ® k Town of Southold Building Department The Office of the Building Inspector 54375 NY-25 Southold, NY 11971 Re: Patrick Wade—740 Country Club Drive, Cutchogue, NY 11935 Single Family Residence,Solar Panel Installation Certification Town of Southold, County of Suffolk, State of New York Dear Building Department, I have reviewed the solar energy system installation at the subject address. The system has been installed in accordance with the manufacturer's installation instructions and the approved construction drawing. I have determined that the installation meets all building code requirements and is certified as for all code and approved plans for the Town of Southold. I completed my final inspection on January 25, 2025 and I can hereby certify that the installation complies with the 2020 New York State Residential Building Code and all applicable codes and design loads as referenced on the approved plans, including ASCE 7-16 (Minimum Design Loads and Associated Criteria for Buildings and Other Structures). If you have any questions, please feel free to call me at any.time.Thanks, in advance. Sincerely Yours, OF N E w r— a�'►• Michael E. Miele PE w � 079876 P A�CFESSIONP� 33 Quaker Ave. PO Box 530,Cornwall, NY 12518 ♦ Phone 845.629.9693 ♦ NYPSengineer@gmail.com FIELD INSPECTION REPORT DATE COMMENTS ro r� FOUNDATION (1ST) 3 ----------------------------------- C coo FOUNDATION (2ND) cn yo ROUGH FRAMING& PLUMBING W t ' � d r INSULATION PER N.Y. y STATE ENERGY CODE CT/G y� I #e-4e tit C 0' o y FINAL 3m ADDITIONAL COMMENTS A izo 3 • I • � � J1/' �c d v� -�-o J a yes . z CIO t � ro �o J z H x d m b TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O.Box 1179 Southold,NY 11971-0959 �y�• �a� ' Telephone (631) 765-1802 Fax(631) 765-9502 hgps://www.southoldtowna.2ov 1#.9' Date.Recelyed APPLICATION FOR BUILDING PERMIT For Office Use Only ; r,! PERMIT NO.f5is Building Inspector: } �% NOV 1 ,$ 2024 Applications and forms must be filled out in their entirety.Incomplete applications will not be accepted. Where the Applicant is not the owner,an " C,1,'�i Owner's Authorization form(Page 2)shall be completed. Date: I 111 Z L( OWNER(S)OF PROPERTY: Name: • SCTM#1000- 1 O Physical Address: 740 Country Club Dri e, Cutchogue NY 11935 Phone#: 646-345-1779 Email: jmccarthy248@gmail:com .Mailing Address: 740 Country Club Drive, Cutchogue NY 11935 CONTACT PERSON: . Name:Permit Dept./Long Island Power Solutions Mailing Address:2060 Ocean Ave., Ronkonkoma, NY 11779 Phone#:631-348-0001 Email:permits@GoPowerSolutions.com DESIGN PROFESSIONAL INFORMATION:' Name: Mic.l�gel- Mailing Address: .33 62�-4!sk�,F- ve C ornwal( N •y. 1 4 S l is Phone#: gN,r_ �oa`I_ 9693 Email: NYt ee% _Ine-e.r @ rr.g,I. C0M CONTRACTOR INFORMATION: Name:Michael Catizone/Long Island Power Solutions Mailing Address:2060 Ocean Ave., Ronkonkoma, NY 11779 Phone#:631-348-0001 Email:Mike @ GoPowerSolutions.com DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition RAlteration ❑Repair ❑Demolition Estimated Cost of Project: igOther Proposed( I g )panel roof mounted array. ( C7.&TID)kW System Will the lot be re-graded? ❑Yes 9No Will excess fill be removed from premises? ❑Yes BNo 1 PROPERTY INFORMATION Existing Use of property:Single Family Dwelling Intended use of property:Single Family Dwelling _ Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes ®No IF YES, PROVIDE A COPY. 8 Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Catizone Electrical/Long Island Power Solutions Application Submitted By(print name): BAuthorized Agent ❑Owner Signature of Applicant: 1,4� _ _ _ Date: STATE OF NEW YORK) SS: COUNTY OF Suffolk ) Michael Catizone being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Contractor (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this 1r�day of WL"Ie6bec ,20 _A gj—CZ-eo ZA"// Notary Public ESCAYLIN CRISOL RIVERA RODRIGUEZ NOTARY PUBLIC-STATE OF NEW YORK No. 01 RI6434031 PROPERTY OWNER AUTHORIZATION Qualified in Suffolk County (Where the applicant is not the owner) My Commission Expires 05-31-2026 I, residing at 740 Country Club Drive, Cutchogue NY 11936 Michael Catizone/Long Island Power Solutions do hereby authorize to apply on my behalf to the Town of Southold Building Department for approval as described herein. O nel's Signatur Date Print Owner's Name 2 BUILDING DEPARTMENT-Electrical Inspector TOWN OF SOUTHOLD ' =' Town Hall Annex- 54375 Main Road - PO Box 1179 Southold,, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 roger rOsoutholdtownny.qov_f:.!�-seandgPsoutholdtownnygov. j _ . " APPLICATION FOR ELECTRICAL INSPECTI:OU .1 ELECTRICIAN INFORMATION (All Information Required) Date: 11 Company Name: catizone Electrical/Long.Island Power Solutions Name: Michael Catizone - d License No.: M C 535 Cop email: Permits@GoPowerSolutions.com Address: 2060 Ocean Avenue,Ronkonkoma,NY 11779 Phone No.: 631-348-0001 JOB SITE INFORMATION (Ail information Required) — Name: Address: 740 Country Club Drive, ogue N 14935 - - - - Cross Street: Moores La�e_ Phone No.:646-345-1779- Bldg.Permit#: Jr email. jmccarthy218@gmail.com Tax__Map District: _ 1000 Section: _1_oq _�Block:a — _Lot: a,. i o BRIEF DESCRIPTION OF WORK (Please Print Clearly) Proposed( (g )panel roof mounted array. (rf, (so )kW System — - — -_ - Circle All That Apply: Is job ready for inspection?: YES/ NO Rough In Final Do you need a Temp Certificate?: YES/ NO Y P Issued On• Temp Information: (All information required) .� Service Size 1 Ph 3 Ph Size:A __-A #Meters _____ . _ ,Old Meter# . New Service- Fire Reconnect-Flood Reconnect-Service Reconnected- Underground-Overhead #Underground Laterals 1 2 H Frame.- Pole- .Work done on Service? Y N Additional'Information`.` Tn V t.- y w E r,e h g si .�Q g M C M_ c,rS .Mod�.tes (. igl {�4r`wl�a Q . ce11•. Q.Ti-o., - �-(as. ,I PAYMENT DUE WITH APPLICATION. _ t .1 Request'for Inspection ForinAs - .A 1.�. t'i•�•'.:.�;a,+~•. ��.,yc-4.,.'.:y'b.';•�• •' �''c.iv ti s� F H ••,a 1 e'.'�,tir:�::i .�.•..:.a..,+aw.ru.�1,.�� .,.,;�y��� ..�.� n ;� — _ r ,� .s'RE' s•���r`.q- �- •�•pC^�..,,a :a•Ar•.+.•a•7 �y�'iLa��:.`• •—,}..--_•. �' � +:,�r'ay"'.e../�.is�.^'_;'}^,G+`;CJ...��•.`3 v:.a�4s.�..'i.- .0 y.. •��G=;;,y` r!:7r9_.`� 4..t•:!.�...�Ya.'. •e.'z�ce—•fie" �..-•�,_�.�_�yv..ci'...�::.�:+°•••�'��•,.;{,..'s `�'%•4L+ • _. .•y. t' .sir•:_ •`Ah. �.�.r y;: _. ..-'s..S�,Ytiir'a.�i•�-u�.v...wY7•�•�^'c"F,:::^n:'e+.:2:..+�•,r''.41sr:'•3a4.:.�.CN.�•.'.::..�.W..a.`^1�. Survey fmr lAe au DOM$NICO MAUTARBUI & �" as 't try oyAto JBI.ANTA Xsat 6UCZY ct„�Bettacae^ LLI At OUUAOH- tw 401• Town 8Mdho°ttd -�� Suffolk Leanly,PlAer York uvA,1aMh•iWAO•oaao•wxmo 7 CAtCI•bt0• ww. ; am R + 1 a.UM 1I.1.4OAbvoialo.♦.vAa nauAa. .lot 24 a° ar�'olcadl a�wr►aiAmiAin . M� d•4 � W L'CL 17,1�1�Af I�L•A6 OiL ' Lai 26 A • �� tti OATb On 14 U" �A1r .• AIA AaLW-f1/ I. m11/MD le. M MIA MMU CMOAUWnLTA LAID MW Aw i \\ 'MUMM¢.COIOMY 454 l �, �1��• .Urtt w►oe xsaLs porasIL s DRIVEh� �. \7 tS /1gWt�fINA�BA/pA1,VAYAYIi; !� {u�7AFOD7 IIRA l MM—F- LONG ISLAND Am OW tE R 2060 Ocean Ave Ronkonkoma, NY 11779 OLV T I O r 631 348-0001 '``��11 www.longislandpowersolutions.com November 12, 2024 TOWN OF SOUTHOLD—Building Division Town Hall Annex Building 54375 Route 25 P.O. Box 1179 Southold,NY 11971 Dear Building Dept: As per your Building Department, enclosed please find the building p'rmit application, subiziittecl oil behalf of our client/property owner: Property Owner: Patrick Wade&Jent),ifer McCarthy—6-6-345-1779 Project/Property Address: 740 Country Club Dr, Cutchogue,NY 11935 Section/Block/Lot: 1000-109-3-2.10 Electrician/36178-ME: Michael Catizone—N60 Ocean Ave.,Rohl+onkoma,NY 11779—(631)348-0001 Contractor/53562-H: Ll Power Solutions=2060 Ocean Ave,,Ronkonkoma,NY 11779-(63)l)348-0001 Architecture&Planning; Michael E.Miele, Pb—33 Quaker Ave,Copiwall,NY 12518-844-629-9693 Enclosed Please find: • Application Fee: $325.00 • Permit Application • (4) Copies of the Property Survey • (4) Copies of the Engineering Drawings & Specs • Liability,Disability&Workman's C01111)Insurance Celts Please send the Receipt and Permit to Long Islar}d Power Solutions. Should you require anytli fig further, please contact me. Sincerely; Sue Estabrooke Permit Manager Long Island.Power Solutions 2060 Ocean Avenue Ronkonkoma,NY 11779 Ph- 631,-348-0001 Fx- 631-348,001$ sue@longistandpowersolutions.com longislandpowersolutions.com Go Green Save Green LONG.ISLAND OW. ER . 2060 Ocean Ave Ronkonkoma, NY 1.1779 631 348=0001 SOLUTIONS www.longislandpowersolutions.com TOWN OF SOUTHOLD-Building Division Town Hall Annex Building 54375 Route 25 \\ , P.O. Box 1179. Southold;.NY 11971 Dear Building Dept; As your Building Department,enclosed'please find AS BUILT for: PERMIT# 51549 Property Owner: Patric Wade Project/Property,Address:,, 740 Country Club Drive,'Cutchogue NY.11935 SectionBlock/Lot: 109.-3-02.10 . . wHAN'GF�S• . . Electrical Change,please refer.to-PLAN PV-4 . Kindly,mail the Approved Drawings to Long Island Power Solutions,2060 Ocean Ave Ronkonkoma,NY'1:1779. Should you have anyquestions.or require anything further please call the office. Sincerely,. . Sue-Estabrooke .Permit Manager - Long Island Power Solutions .2060 Ocean Ave Ronkonkoma,NY 11779 Ph- 631-348-0001 Fx- 631-348-0018 G 40 Sue@GoPowerSolutions:com J Go Green Save Green AP R VED AS NOTED DATE• L B.P.it FEE ' BY NOTIFY BUILDING DEPARTMENT AT 631 765-1802 8AM TO 4PM FOR THE FOLLOWING INSPECTIONS: 1. FOUNDATION-TWO REQUIRED FOR POURED CONCRETE 2. ROUGH-FRAMING&PLUMBING 3. INSULATION 4. FINAL-CONSTRUCTION MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OFTHE CODES OF NEW ELECTRICAL YORK STATE. NOT RESPONSIBLE FOR INSPECTION REQUIRED DESIGN OR CONSTRUCTON ERRORS COMPLY WITH ALL CODES OF NEW YORK STATE&TOWN CODES AS REQUIRED AND CONDITIONS OF F ZBA PUNNING BOARD TRUSTEES OCCUPANCY OR USE IS UNLAWFUL WITHOUT CERTIFICAT OF OCCUPANCY ' a Michael E. Miele, PE Licensed Professional Engineer Licensed In New York, New Jersey, Connecticut&California New York License#079676 New Jersey License#44042 Connecticut License#23158 California License#31508 October 29,2024 Town of Southold Building Department The Office of the Building Inspector 54375 NY-25 Southold, NY 11971 Re: Patrick Wade—740 Country Club Drive, Cutchogue, NY 11935 Single Family Residence,Solar Panel Loading Certification Town of Southold, County of Suffolk,State of New York Dear Building Department ti I am the engineer of record for the above referenced project. I have prepared the attached plans dated October 18,2024 that consist of the installation of(18)Q.TRON BILK M-G2+425W solar panels at the above referenced location. I can hereby certify that the existing roof structure combined with the additional weight of the solar panels meets the requirements of The 2020 Residential Code of New York State, Publication Date, November 2019. The design loads were as follows, Roof Design Load: 20psf live load Wind Design Load: 140mph No additional structural members were required. The roof is currently framed with 2x8 wood framing @ 16" O.C. The roof structural members are in compliance with ASCE 7-16 for deflection and acceptable bending stress. If you have any questions, please feel free to call me at any time.Thanks in advance. Sincerely Yours, QF RE 0� 'k /D'Z9j1�1 Michael E. Miele, PE 079676 A��FESSIONP� 33 Quaker Avenue, PO BOX 530,Cornwall, NY 12518 ♦ Phone:845.629.9693♦ NYPSengineer@gmail.com CONTRACTOR PATRICK WADE owER SOLUTIONS AHJ SCOPE OF WORK UTILITY (N)7.650KW DC ROOF MOUNTED PV SYSTEM VICINITY MAP TOWN OF SOUTHOLD LONG ISLAND POWER LONG ISLAND POWER (18) HANWAH Q CELL Q.TRON BLK M-G2+425W MODULES AUTHORITY -----� SOLUTIONS tjorc�nese ►-s.,, T (18) ENPHASE IQ8MC-72-M-US MICROINVERTERS Hargrave Alex{Eyrrone 'Gall 2060 OCEAN AVENUE (01) ENPHASE IQ COMBINER 4/4C PANEL ^^^ RONKONKOMA, NY 11779 Nlacari�Vlneyards r winery 'r�`�,: :; `� +1 631 348 0001 CODES AND STANDARDS WITH AMENDMENTS 2020 BCNYSrj" PROJECT INFO&ADDRESS 2020 FCNYS �- " Y ss A r "1 _ PATRICK WADE 2020 RCNYS � , �740 CountryCIubjDr 2017 NEC °' :Cutd6ogue i�436 740 COUNTRY CLUB DR, �� ti CUTCHOGUE ENVIRONMENTAL r,oy d9 5 � NY 11936 WIND SPEED: 140 MPH SNOW LOAD: 20 PSF 126 E' � `� i SYSTEM SIZE EXPOSURE CATEGORY: B DC SIZE: 7.650 KW DC-(STC) GENERAL NOTES SHEET INDEX NOTES 1. TO THE BEST OF MY KNOWLEDGE, PV-1 COVER SHEET BELIEF AND PROFESSIONAL PROJECT NOTES: JUDGMENT,THE PLANS AND -THIS PHOTOVOLTAIC(PV)SYSTEM SHALL COMPLY WITH PV-2 SITE PLAN-1 COMPLSPECIFIANCE WITH T E PV-2.1 SITE PLAN-2 COMPLIANCE WITH THE 2020 THE NATIONAL ELECTRIC CODE(NEC)ARTICLE 690,ALL PV-3 ATTACHMENT PLAN RESIDENTIAL CODE OF NEW YORK MANUFACTURER'S LISTING AND INSTALLATION STATE.PV 3.1 STRUCTURAL PLAN 2. IT IS A VIOLATION OF THE LAW FOR INSTRUCTIONS,AND THE RELEVANT CODES AS SPECIFIED PV-4 ELECTRICAL ANY PERSON,UNLESS ACTING BY THE AUTHORITY HAVING JURISDICTION'S (AHJ) METER NO: 98298120 PV-4.1 ELECTRICAL CALCULATIONS UNDER THE DIRECTIONOFA LICENSED PROFESSIONAL,TO APPLICABLE CODES. PV-5 LABELS ALTER AN ITEM IN ANY WAY.IF AN -THE UTILITY INTERCONNECTION APPLICATION MUST BE ACCT NO: 9621071403 PV-6 RESOURCE DOCUMENT ITEM BEARING THE SEAL I A APPROVED AND PV SYSTEM INSPECTED PRIOR TO LICENSED PROFESSIONNAL s PARALLEL OPERATION PV-6.1 RESOURCE DOCUMENT PROFESSIONAL SHALL AFFIX TOALTERED,THE ALTERING -GROUND FAULT DETECTION AND INTERRUPTION (GFDI) PV-6.2 RESOURCE DOCUMENT THEIR ITEM THEIR SEAL AND THE DEVICE IS INTEGRATED WITH THE POWER OPTIMIZER IN PV-6.3 RESOURCE DOCUMENT NOTATION"ALTERED Br' PV-6.4 RESOURCE DOCUMENT FOLLOWED BY THEIR SIGNATURE ACCORDANCE WITH NEC 690.41(B) AND THE DATE OF SUCH PV-6 -ALL PV SYSTEM COMPONENTS; MODULES, UTILITY- .5 RESOURCE DOCUMENT ALSC a FIC INTERACTIVE INVERTERS,AND SOURCE CIRCUIT COMBINER PV-6.6 RESOURCE DOCUMENT DE SCR I� ION. BOXES ARE IDENTIFIED AND LISTED FOR USE IN PV-6.7 RESOURCE DOCUMENT E. PHOTOVOLTAIC SYSTEMS AS REQUIRED BY NEC 690.4: PV PV-6.8 RESOURCE DOCUMENT Gj MODULES: UL1703, IEC61730,AND IEC61215,AND NFPA 70 CLASS C FIRE INVERTERS: UL 1741 CERTIFIED, IEEE 1547, W 929, 519 COMBINER BOX(ES): UL 1703 OR UL 1741 2 ACCESSORY Z "' -MAX DC VOLTAGE CALCULATED USING MANUFACTURER 079676 PROVIDED TEMP COEFFICIENT FOR VOC. IF UNAVAILABLE, FESSloNP� MAX DC VOLTAGE CALCULATED ACCORDING TO NEC 690.7. -ALL INVERTERS, PHOTOVOLTAIC MODULES,PHOTOVOLTAIC DRAWN BY BA PANELS,AND SOURCE CIRCUIT COMBINERS INTENDED FOR USE IN A PHOTOVOLTAIC POWER SYSTEM WILL BE DATE 10/18/2024 IDENTIFIED AND LISTED FOR THE APPLICATION PER 690.4. REVISION SHALL BE INSTALLED ACCORDING TO ANY INSTRUCTIONS FROM LISTING OR LABELING[NEC 110.31. SIGNATURE -ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE. IF EXPOSED TO SUNLIGHT, IT SHALL BE UV PV-1 RESISTANT.ALL PLAQUES AND SIGNAGE WILL BE INSTALLED AS REQUIRED BY THE NEC AND AHJ. COVER SHEET SCOPE OF WORK TOTAL ROOF SQUARE FOOTAGE IS:'2499.07 FP i NEW ARRAY SQUARE FOOTAGE IS: 378.35 FT2 CONTRACTOR``--''CC (K)7.650KW DC ROOF MOUNTED PV SYSTEM 0, o O�I'GR (18)HANWAH Q CELL Q.TRON BLK M-G2+425W MODULES COVERED BY SOLAR IS: 15.14/o \ISOLUTIONS (18)ENPHASE IQ8MC-72-M-US MICROINVERTERS (01)ENPHASE IQ COMBINER 4/4C PANEL LONG ISLAND POWER SOLUTIONS 2060 OCEAN AVENUE - - - RONKONKOMA, NY 11779 (E)POOL +1 631 348 0601 ♦♦ PROJECT INFO&ADDRESS ♦,00 PATRICK WADE 740 COUNTRY CLUB DR, ZZ / CUTCHOGUE, i � NY 11935 SYSTEM SIZE ' DC SIZE: 7.650 KW DC-(STC) � ♦7 p,, NOTES 1. TO THE BEST OF MY KNOWLEDGE, - BELIEF AND PROFESSIONAL Q JUDGMENT,THE PLANS AND SPECIFICATIONS ARE IN COMPLIANCE WITH THE 2020 �A RESIDENTIAL CODE OF NEW YORK STATE. (� 2. IT IS A VIOLATION OF THE LAW FOR ANY PERSON,UNLESS ACTING—�4 \ \ \ UNDER THE DIRECTION OF A LICENSED PROFESSIONAL,TO \ ALTER AN ITEM IN ANY WAY.IF AN ITEM BEARING THE SEAL OF A LICENSED PROFESSIONAL IS ALTERED,THE ALTERING LICENSED \ PROFESSIONAL SHALL AFFIX TO \ THEIR ITEM THEIR SEAL AND THE NOTATION\ o ALTERED BY" FOLLOWED'BY THEIR SIGNATURE ` AND THE DATE OF SUCH ♦ ALTERATION,AND A SPECIFIC \ tK DESCRIP BI TERATION. E. p� \ 2_5„ 0 LEGEND \ $$-°� till ®FIRE PATHWAYS l ��� A 0796716 PROPERTY LINE Lo,' 0 FENCE R DRAWN BY BA ® SKYLIGHT/CHIMNEY vB D" DATE 10/18/2024 O ❑ VENT/OBSTRUCTION �� ' REVISION SIGNATURE SITE PLAN-1 PV-2 SCALE:1/32" = V-0" SITE PLAN-1 CONTRACTOR SCOPE OF WORK TOTAL ROOF SQUARE FOOTAGE IS:2499.07 FT2 (N)7.65OKW DC ROOF MOUNTED PV SYSTEM NEW ARRAY SQUARE FOOTAGE IS: 378.35 FT2 (18)'HANWAH Q CELL Q.TRON BILK M-132+425W MODULES COVERED BY SOLAR IS: 15.14% Adr)OWER (18) ENPHASE IQ8MC-72-M-US MICROINVERTERS SOLUTIONS (01) ENPHASE IQ COMBINER 4/4C PANEL LONG ISLAND POWER SOLUTIONS 2060 OCEAN AVENUE RONKONKOMA, NY 11779 +1 631 348 0001 - - � PROJECT INFO 8 ADDRESS 3 PATRICK WADE I 740 COUNTRY CLUB DR, N:) AH Q. ..... ,TRON BLK M-G2+ CUTCHOGUE, 425W MODULES WITH ENPHASE IQ8MC-72-M-US NY 11936 MICROINVERTERS UNDER EACH MODULE(240V) SYSTEM SIZE t�?O', DC SIZE: 7.650 KW DC-(STC) d NOTES 1. TO THE BEST OF MY KNOWLEDGE, O >• BELIEF AND PROFESSIONAL LADDER ACCESS JUDGMENT,THE PLANS AND R,O a SPECIFICATIONS ARE IN COMPLIANCE WITH THE 2020 a m RESIDENTIAL CODE OF NEW YORK o STATE. s O 2. IT IS A VIOLATION OF THE LAW FOR (� e •- ANY PERSON,UNLESS ACTING / t UNDER THE DIRECTION OF A O ° LICENSED PROFESSIONAL,TO _ ALTER AN ITEM IN ANY WAY.IF AN ITEM BEARING THE SEAL OF A LICENSED PROFESSIONAL IS Q is�O ALTERED,THE ALTERING LICENSED ;PROFESSIONAL SHALL AFFIX TO THEIR ITEM THEIR SEAL AND THE = NOTATION"ALTERED BY" FOLLOWED BY THEIR SIGNATURE ANDSHE DATE OF SUCH ALTERATIO ,AN CIFIC \ DESCA QF AT ION. (N)ENPHASE IQ COMBINER 4/4C �. O ��Q'G�p.� O WITH ENPHASE IQ GATEWAY 3.O (OUTSIDE HOUSE) (N)VISIBLE LOCKABLE LABELED v LEGEND AND FUSED AC DISCONNECT 900 �sA W ®FIRE PATHWAYS PROPERTY LINE (UTILITY(OUTD GO SSDE HOUSE) v� � 079613 'ORp N -0—FENCE ® SKYLIGHT/CHIMNEY (E)UTILITY METER DRAWN BY BA UNDERGROUND SERVICE) (N)JUNCTION BOX O ❑ VENT/OBSTRUCTION ( NEMA 4X RATED DATE 10/18/2024 (OUTSIDE HOUSE) (E)MAIN SERVICE PANEL (N)CONDUIT RUN REVISION (INSIDE BASEMENT) SIGNATURE SITE PLAN-2 PV-2.1 SCALE032". = V-0" SITE PLAN-2 ROOF SECTION(S) CONTRACTOR N OWER ROOF MATERIAL- 6 8 SOLUTIONS 1 1 n COMPOSITE SHINGLE � ROOF 1 RAFTER SIZE-2"X8" O.C. SPACING- 16" MODULES- 16 LONG ISLAND POWER I I I I I I I I I I I I I I I I I I I I I I ROOF MATERIAL- I I I SOLUTIONS ROOF 2 COMPOSITE SHINGLE 2060 OCEAN AVENUE RAFTER SIZE-2"X8" _ 1 _I_ -_I__i_ I I I I I I I I I I I t I I I I RONKONKOMA NY 11779 O.C. SPACING- 16" I I I I I I I I I I I I I I I I I I I I I MODULES-2 I I I I I I I I I I I I I I I I I I I I +1 631 348 0001 I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I t I I IAL 1 I 1 I A I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I PROJECT INFO&ADDRESS - CLAMP (N 1 I PATRICK WADE • I I I I I I I I I I I I I I I I I I 740 COUNTRY CLUB DR, - IRONRIDGE FLASHFOOT 2 CUTCHOGUE, - IRONRIDGE XR-100 RAIL I i I 1 1 I I 10 i i I I 1 1 1 1 I I i i NY 11935 I I I I I I IT I I TI I I I I I I I I I I I Ii i i I I I 1 I I I I I I I I I i i i I I i i I I I I I SYSTEM SIZE __________ - RAFTER , 1 , 1 I I DC SIZE: 7.650 KW DC-(STC) I I 1 I I 54 - TOTAL MOUNT 10" 31'-011 911 NOTES 1. TO THE BEST OF MY KNOWLEDGE, BELIEF AND PROFESSIONAL JUDGENT,THE PLANS ARRAY 1 SPEC FICATIONS ARE INAND COMPLIANCE WITH THE 2020 TILT- 16 DEG RESIDENTIAL CODE OF NEW YORK AZIMUTH - 330 DEG 2. T S A VIOLATION OF THE LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL,TO J� ALTER AN ITEM IN ANY WAY.IF AN ITEM BEARING THE SEAL OF A LICENSED PROFESSIONAL IS ALTERED,THE ALTERING LICENSED r PROFESSIONAL SHALL AFFIX TO 1 1 I I I 1 I THEIR ITEM THEIR SEAL AND THE Lc) , I I I I I I NOTATION"ALTERED BY" I I I I I I I I I 1 FOLLOWED BY THEIR SIGNATURE AND THE DATE OF SUCH I I I I I I I ALTERATJQIF�ikfl' ECIFIC I I I t DESC I TION. I I I 1 Lo I I I 1 i n c+� I I I 1 I I I I I I I I I I I I I I I I 07 76 1 I , � I I DRAWN BY BA 81-311 6-811 41-311 DATE 10/18/2024 REVISION ARRAY 2 SIGNATURE 1 ATTACHMENT PLAN TILT- 14 DEG PV-3 AZIMUTH - 240 DEG SCALE:3/16"=V-0" ATTACHMENT PLAN CONTRACTOR &DOWER \ISOLUTIONS LONG ISLAND POWER SOLUTIONS 2060 OCEAN AVENUE MODULE - - --- BOTTOM MOUNTING CLIP RO 631 NKOMA, NY11779 CLAMP w4 ' BOLT AND LOCK WASHER PROJECT INFO&ADDRESS PATRICK WADE MODULE 740 COUNTRY CLUB DR, CUTCHOGUE, NY 11936 IRONRIDGE XR-100 RAIL / / SYSTEM SIZE / DC SIZE: 7.650 KW DC-(STC) / 3 ' BOLT NOTES S j / 1. TO THE BEST OF MY KNOWLEDGE, (E) COMPOSITE SHINGLE BELIEF AND PROFESSIONAL JUDGMENT,THE PLANS AND / SPECIFICATIONS ARE IN / COMPLIANCE WITH THE 2020 RESIDENTIAL CODE OF NEW YORK IRONRIDGE FLASHFOOT2 STATE. 2. IT IS A VIOLATION OF THE LAW FOR ANY PERSON,UNLESS ACTING 5/16" x 5" STAINLESS STEEL DIA LAG UNDER THEDIOF A LICENSED PROFESSIFESSINONALAL,, TO FLASHING ALTER A ITEM IN ANY WAY.IF AN BOLTS MIN. 2.5" EMBEDMENT ITEM BEARING THE SEAL OF A LICENSED PROFESSIONAL IS ALTERED,THE ALTERING LICENSED PROFESSIONAL SHALL AFFIX TO THEIR ITEM THEIR SEAL AND THE NOTATION"ALTERED BY" FOLLOWED BY THEIR SIGNATURE AND THE DATE OF SUCH ALTE FIC DESC PIlO Ft�,T� TION. OC W IVA 2 N 07 6-16 � (E) RAFTER 211X8" @ 16" O.C. ARo�ssloNP`' Z DRAWN BY BA DATE 10/18/2024 REVISION SIGNATURE 1 STRUCTURAL PLAN PV-3.1 SCALE:NTS STRUCTURAL PLAN SOLAR MODULE SPECIFICATIONS INVERTER SPECIFICATIONS CONTRACTOR HANWAH Q CELL Q.TRON BLK ENPHASE IQ8MC-72-M-US NOTE: - MANUFACTURER/MODEL# _ MANUFACTURER MODEL# - ALL CONDUCTORS ARE COPPER UNLESS OTHERWISE OWER M-G2+425W MICROINVERTER NOTED. pL�J'r��Ns 4 VMP 32.98V MIN/MAX DC VOLT RATING 22V MIN/58V MAX IMP 12.88A MAX INPUT POWER 460W VOC 38.67V NOMINAL AC VOLTAGE RATING 240V/211-264V LONG ISLAND POWER ISC 13.49A MAX AC CURRENT 1.33A SOLUTIONS TEMP. COEFF.VOC -0.24%/K MAX MODULES PER STRING 12(SINGLE PHASE) METER NO: 98298120 2060 OCEAN AVENUE 'RONKONKOMA, NY 11779 MODULE DIMENSION 67.8"L x 44.6"W x 1.18"D (In Inch) MAX OUTPUT POWER 320 VA ACCT NO: 9621071403 +1 631 348 0001 TO UTILITY GRID (N) (1) ENPHASE IQ COMBINER 4/4C L1 L2 N PROJECT INFO&ADDRESS (N)(18)HANWAH Q CELL Q.TRON BLK M-G2+425W MODULES WITH ENPHASE IQ GATEWAY, PATRICK WADE (2)20A/240VAC CIRCUIT LINE 740 COUNTRY.CLUB DR, BREAKERS 125A RATED (E)BI-DIRECTIONAL UTILITY (N) (1)AC DISCONNECT: METER 1-PHASE,3-w, CUTCHOGUE, , 9 MICROINVERTERS IN BRANCH CIRCUIT 1 (OUTSIDE HOUSE) VISIBLE, LOCKABLE, LABELED M 120V124OV,20.0ARATED NY 11936 (2)#12 Q CABLES 60A FUSED, (2)30A FUSES,240V LOAD (OUTSIDE(UNDERGRHOUSE)OUND SERVICE) o . . . NEMA 3R, UL LISTED SYSTEM SIZE PER MANUFACTURER IQ GATEWAY (UTILITY DISCONNECT) DC SIZE: 7.650 KW DC-(STC) SPECIFICATIONS,EITHER (OUTSIDE HOUSE) n 10A OR 15A OR 20A oM ESS 16E ^, I ^, I ti I BREAKER IS Li Li SUPPLY SIDE TAP NOTES `-'�— — �--�— ——— �---� SUITABLE FOR USE L2 L2 1. TO THE BEST OF MY KNOWLEDGE, BELIEF AND PROFESSIONAL (N)(1)JUNCTION 15A/2P N G JUDGMENT,THE PLANS AND BOX 600V,NEMA 4X ^ G — -� (E)MAIN BREAKER TO SPECIFICATIONS ARE IN 9 MICROINVERTERS IN BRANCH CIRCUIT 2 RATED 2 — LINE I HOUSE 240 V,200A/2P COMPLIANCE WITH THE 2020 (TOP FED) RESIDENTIAL CODE OF NEW YORK L1 20A/2P 3 I -- I 4 2. IT IS A VIOLATION OF THE LAW FOR • • • L2 I I p (E)MAIN SERVICE PANEL ANY PERSON,UNLESS ACTING 200A RATED,240V UNDER THE DIRECTION OF A I -I I I 1j I _ I I I i i I � (INSIDE BASEMENT) LICENSED PROFESSIONAL,TO I - I - I 20PJ2P I ITEM BEARING THE EAALTER AN ITEM IN ANY IL OF A AY.IF AN LINE SIDE LICENSED PROFESSIONAL IS o INTERCONNECTION ALTERED,THE ALTERING LICENSED L2 I LOAD I I o AT MAIN SERVICE PANEL PROFESSIONAL SHALL AFFIX TO PER ART.705.12(A) THEIR ITEM THEIR SEAL AND THE I I I NOTATION"ALTERED BY" (N)(18)ENPHASE IQ8MC-72-M-US FOLLOWED BY THEIR SIGNATURE MICROINVERTERS ONE UNDER EACH I I N MODULE(240V) I I L AND THE DATE OF SUCH G ALTERATION,AND A SPECIFIC L-- ----J - I DESCRIP M�*'TFI LTERATION. N I GEC �( ''O L — G — G EXISTING GROUNDING ,A ELECTRODE SYSTEM 1 TO EARTH REF. NEC 250.52, I- 250.53(A) m r� A 07 61fO ESS DRAWN BY BA ID PHASE CONDUCTOR QTY,SIZE AND TYPE SIZE AND TYPE PER CONDUIT GROUND CONDUCTOR QTY,SIZE CONDUIT CONDUIT DATE 10/18/2024 PER CONDUIT NEUTRAL QTY, AND TYPE PER CONDUIT SIZE TYPE REVISION 1 2 AWG#12 Q-CABLE NA NA NA 1 AWG#6 BARE,COPPER EGC N/A FREE AIR SIGNATURE 2 4 AWG#10 THWN-2,COPPER NA NA NA 1 AWG#8 THWN-2,COPPER EGC 1" PVC 3 2 AWG#6 THWN-2,COPPER 1 AWG#6 THWN-2,COPPER 1 AWG#8 THWN-2,COPPER EGC V PVC PV-4 4 2 AWG#6 THWN-2,COPPER 1 AWG#6 THWN-2,COPPER 1 AWG#8 THWN-2,COPPER EGC 1" PVC ELECTRICAL CONTRACTOR AMBIENT TEMPERATURE SPECS ��OWER RECORD LOW TEMP -150 PERCENT OF NUMBER OF CURRENT \ISOLUTIONS AMBIENT TEMP (HIGH TEMP 2%) 31° VALUES CARRYING CONDUCTORS IN CONDUIT LONG ISLAND POWER CONDUIT HEIGHT 7/8" .80 4-6 SOLUTIONS ROOF TOP TEMP 53° 2060 OCEAN AVENUE .70 7-9 RONKONKOMA, NY 11779 CONDUCTOR TEMPERATURE RATE 75° .50 10-20 +1 631 348 0001 MODULE TEMPERATURE COEFFICIENT OF Voc -0.24%/K PROJECT INFO&ADDRESS PATRICK WADE CALCULATIONS: 740 COUNTRY CLUB DR, CUTCHOGUE, NY 11935 1. CURRENT CARRYING CONDUCTOR 2. PV OVER CURRENT PROTECTION ...NEC 690.9(B) = TOTAL INVERTER O/P CURRENT x 1.25 SYSTEM SIZE DC SIZE: 7.650 KW DC-(STC) (A) BEFORE IQ COMBINER PANEL = (18 x 1.33) x 1.25 = 29.93 A AMBIENT TEMPERATURE - (31)OC ...NEC 310.15(B)(2)(a) NOTES TEMPERATURE DERATE FACTOR - 0.94 ...NEC 310.15(B)(2)(a) 1. BE THE BEST OF BELIEF AND PROFEE KNOWLEDGE,SSIONAL ' JUDGMENT,THE PLANS AND GROUPING FACTOR - 0.8...NEC 310.15(B)(3)(a) SPECIFICATIONS ARE IN COMPLIANCE WITH THE 2020 RESIDENTIAL CODE OF NEW YORK STATE. LATION OF THE LAW CONDUCTOR AMPACITY 2. ANYPE SON,UNLESS AC TING FOR = (INV O/P CURRENT ) x 1.25 / A.T.F / G.F ...NEC 690.8(B) UNDER CE SED PROFESSIONAL,TO = [(9 x 1.33) x 1.251 / [0.94 x 0.81 ALTER AN ITEM IN ANY WAY.IF AN ITEM BEARING THE SEAL OF A (� (� LICENSED PROFESSIONAL IS = 19.90A ALTERED,THE ALTERING LICENSED PROFESSIONAL SHALL AFFIX TO SELECTED CONDUCTOR - #10 THWN-2 ...NEC 310.15(B)(16) THEIR ITEM THEIR SEAL AND THE NOTATION"ALTERED BY" FOLLOWED BY THEIR SIGNATURE AND THE DATE OF SUCH (B) AFTER IQ COMBINER PANEL ALTERATI FIC DESC T[ON. O TEMPERATURE DERATE FACTOR - 0.94 GROUPING FACTOR - 1 . oc W. W CONDUCTOR AMPACITY = (TOTAL INV O/P CURRENT) x 1.25 / 0.94/ 1 ...NEC 690.8(B) ,oROFESS rbO 1 = [(18x1.33) x1.25] / [0.94x1] = 31.84 A DRAWN BY BA SELECTED CONDUCTOR - #6 THWN-2 ...NEC 310.15(B)(16) DATE 10/18/2024 REVISION SIGNATURE PV-4.1 ELECTRICAL CALCULATIONS CONTRACTOR F-11 "_ ; $ C ION:BOLA EL-c 4DaI�OENR ELECTRIC SHOCK HAZARD ❑� Y T @ WKIEC CAUTION IF A GROUND FAULT IS INDICATED NORMALLY GROUNDED CONDUCTORS POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE LONG ISLAND POWER MAY BE UNGROUNDED AND ENERGIZED SOLAR PV SYSTEM EQUIPPED FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: WITH RAPID SHUTDOWN SOLUTIONS TTURN RAPID SHUTDOWN N 2060 OCEAN AVENUE Z EA SWITCH TO THE RONKONKOMA, NY 11779 ❑ "OFF'POSITION TO W&R-ILEMU15 SHUT DOWN PV SYSTEM � P '� +1 631 348 0001 ELECTRIC SHOCK HAZARD AND REDUCE Q SHOCK HAZARD THE DC CONDUCTORS OF THIS IN THE ARRAY / PHOTOVOLTAIC SYSTEM ARE UNGROUNDED PROJECT INFO&ADDRESS AND MAY BE ENERGIZED GL PATRICK WADE PVARRAY �� 740 COUNTRY CLUB DR, ❑3 IWARNING Fi-ol C ON• S AP - IRCUIT CUTCHOGUE, NY 11935 ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND SYSTEM SIZE LOAD SIDES MAY BE ENERGIZED 0 DC SIZE: 7.650 KW DC-(STC) IN THE OPEN POSITION RATED AC OUTPUT CURRENT •4 AMPS NOMINAL OPERATING AC VOLTAGE 240 VOLTS IL 11 NOTES FROOM41 1. BELIEF AND PROFESONALTO THE BEST OF MY EDGE, • . .. . COMBINER PANEL (OUTSIDE HOUSE) O JUDGMENT,THE PLANS AND , SPECIFICATIONS ARE IN PV DISCONNECT V� COMPLIANCE WITH THE 2020 (OUTSIDE HOUSE) ('� RESIDENTIAL CODE OF NEW YORK WARNING:DUAL P' OURCE ��� v 2. IT IS A VIOLATION OF THE LAW FOR ECOND SOURCE IS HOTOVO T ^ SYSTEM .`� ANY PERSON,UNLESS ACTING UTILITY METER G� UNDER THE DIRECTION OF A LICENSED PROFESSIONAL,TO F6] (UNDERGROUND SERVICE) ALTER AN TEM IN ANY WAY.F AN (OUTSIDE HOUSE) POWER • MAIN SERVICE PANEL ITEM BEARING THE SEAL OF A (INSIDE BASEMENT) LICENSED PROFESSIONAL IS ALTERED,THE ALTERING LICENSED PROFESSIONAL SHALL AFFIX TO . THEIR ITEM THEIR SEAL AND THE [7] INVERTER OUTPUT CONNECTION • NOT NOTATION"ALTERED BY" FOLLOWED BY THEIR SIGNATURE RELOCATEOVERCURRENT DEVICE AND THE DATE OF SUCH ALTERA IC DESC ON. Solar Module Solar Module v Y Micro Inverters Mai service �'< `XP IQ COMBINER AC DISCONNECT G AC Junction Box Outside Door oC ET Outside Door 3,9,10 U 1 3,4 3,6,8,9111 2 Inside 5 6 7 or ado �796T6 Inside Door , R o NPR OEM Cables should be marked by the manufacturer 1 5,6,7 *Custom FESS10 NEC 690.31(G)(3) NEC 690.13(B) Directory DRAWN BY BA NEC 690.54 NEC 690.56(C) Placard DATE 10/18/2024 NEC 705.12(B)(3) NEC 690.13(B) NEC 705.12(B)(2)(3)(b) NEC 690.13(B) REVISION NEC 690.56(B) NEC 705.12(B)(3) NEC 690.56(B) SIGNATURE NEC 705.10 NEC 705.10 NEC 705.12(B)(2)(3)(b) PV-5 NEC 705.12(B)(3) LABELS Q.TRON BLK Im MmG2+ SERIES ocells 415-440 Wp 1108 Cel Is 22.5% Maximum Module Efficiency MODEL Q.TRON BILK M-G2+ Q.APJTUM High performance Qcells N-type NED solar cells Q.ANTUM NEO Technology with optimized module layout boosts module efficiency up to 22.5%. A reliable investment Inclusive 25-year product warranty and 25-year linear Warranty performance warranty'. Enduring high performance Long-term yield security with Anti LeTID Technology,Anti PID .2�ells Technology2,Hot-Spot Protect. Extreme weather rating High-tech aluminium alloy frame,certified for high snow(8100 Pa)and wind loads(3600 Pa). _ Innovative all-weather technology Optimal yields,whatever the weather with excellent low-light and temperature behaviour. n The most thorough testing programme in the industry Qcells Is the first solar module manufacturer to pass the most comprehensive quality programme in the industry:The new"Quality Controlled PV"of the independent certification institute TOV Rheinland. 'See data sheet on rear for further information. APT test conditions according to IEC/TS 62804-1:2015,method A(-1500 V,96h) The ideal solution for: c"wuww� Rooftop arrays on =o�~ ° residential buildings usA ° m'� L/7 O®T'ROiV BLK M-G2+ SERIES ` ■Mechanical Specification Format 67.8 In x 44.6 In x 1.18 In(Including frame) =aa-mea mn7 (1722 mm x 1134 mm x 30 mm) + L Weight 46.7 lbs(21.2 kg) as axv wbu Front Cover 0.13 in(3.2 mm)thermally pre-stressed glassoafi�u with anti-reflection technology Back Cover Composite film __ ® la•ro.A Frame Black anodised aluminium Cell 6 x 18 monocrystalline OANTUM NEO solar half cells tea"-❑ n sa�u Junction box 2.09-3.98inx1.26-2.361nx0.59-0.711n .•NrnagWb (53-101 mm x 32-60 mm x 15-18 mm),Protection class IP67,with bypass diodes +IearAaN =e, + Cable 4mm'Solar cable;(+)2o68.9In(1750mm),(-)a68.9in(1750mm) na pew M-A e�nH Connector Staubll MC4;IP68 Asrpass mylTo2r as M ■Electrical Characteristics POWER CLASS 415 420 425 430 435 440 MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS,STO(POWER TOLERANCE+5W/-0W) Power at MPP' PNa, [W] 415 420 425 430 435 440 Short Circuit Current' Isc [A] 13.49 13.58 13.66 13.74 13.82 13.90 EOpen Circuit Voltage' Voc M 38.47 38.75 39.03 39.32 39.60 39.88 Current at MPP IMpp [A] 12.83 12.91 12.98 13.05 13.13 13.20 Voltage at MPP VM„ M 32.34 32.54 32.74 32.94 33.14 33.33 Efficiency' 1`1 [%] 221.3 ?21.5 221.8 222.0 222.3 222.5 MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS,NMOT2 Power at MPP PH* [W] 313.7 317.5 321.2 325.0 328.8 332.6 E Short Circuit Current Isc [A] 10.87 10.94 11.00 11.07 11.14 11.20 E Open Circuit Voltage Voc M 36.50 36.77 37.04 37.31 37.58 37.84 C Current at MPP IMm [A] 10.10 10.15 10.21 10.27 10.33 10.38 Voltage at MPP Vmaa M 31.07 31.26 31.46 31.65 31.84 32.03 'Measurement tolerances PN,t3%;Ix;Voc t 5%at STC:1000 W/m2,25 t 2°C,AM 1.5 according to IEC 60904-3•2800 W/m2,NMOT,spectrum AM 1.5 Ocells PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE H s �� At least 95.5%of nominal power w o '•mn°° ^^�°^° during first year.Thereafter max Z I I >K O W 0.33%degradation per year.At least 95.53%oi nominal power E +. --+------I------ sosa up to 10 years.At least 90.58%of zo - nominal power up to 25 years. F LL o -0. w so ib c as -- ___ - All data within measurement tolerances.Full warranties In accordance with the warranty °u so terms of the Ocells sales ao o os ,a is xa 2s organisation of your respective 20o soo soo soo Im 4 YEARS country. IRRADIANCE IW1rn j �1 0 -standard terms of guarantee for the 5 PV companies with the Typical module performance under low irradiance conditions In highest production capacity In 2021(February 2021) comparison to STC conditions R50C,1000 Wim21. TEMPERATURE COEFFICIENTS I, Temperature Coefficient of Isc a [%/K] +0.04 Temperature Coefficient of Voc p [%/K] -0.24 Temperature Coefficient of PAS y [%/K] -0.30 Nominal Module Operating Temperature NMOT CF] 109t5.4 (43t3°C) 0 ■Properties for System Design o P Maximum System Voltage Vsys M 1000(IEC)/1000(UL) PV module classification Class II ° Maximum Series Fuse Rating [A DC] 25 Fire Rating based on ANSI/UL 61730 C/TYPE 2 Max.Design Load,Push/Pull' [Ibs/ft'] 113(5400Pa)/50(2400Pa) Permitted Module Temperature -40°F up to+185°F Max Test Load,Push/Pull' [Ibs/ft'] 169(8100Pa)/75(3600Pa) on Continuous Duty (-40°C up to+g5°C) 2 See Installation Manual - 0 D ■Oualifications and Certificates Quality Controlled PV- Tl1V Rheinland; w 3 IEC 61 : /� ❑' ❑• IEC 61730730:201616. "-- This data sheet complies with DIN EN 50380. a us roi„i- 'UL and California Energy Commission(CEC)listings pending Ocells pursues minimizing paper output in consideration of the global environment. Note:Installation instructions must be followed.Contact our technical service for further Information on approved installation of this product ocel I S Hanwha°CELLS America Inc 400 spectrum Center Drive.Suite 1400.Irvine,CA 92618.USA I TEL+1 949 748 59 96 1 MAIL hgc-hquiry*q-U.com I WEB www.gcells.com •r ENPHASE. 1114 lea L vim ' ' I + I j 0 - - IQ8MC Microinverter Easy to install :7 Our newest I08 Series Microinverters are the industry's first microgrid-forming*;software- •.Lightweight and compact with.plug- .. defined microinverters with split-phase power conversion capability to convert DC power to and-play connectors ! AC power efficiently.The brain of the semiconductor-based microinverter is our proprietary Power line communication(PLC) application-specific integrated circuit(ASIC),which enables the microinverter to operate in between components grid-tied or off-grid modes.This chip is built in advanced 55-nm technology with high-speed • Faster installation with.simple two-wire j digital logic and has superfast response times to changing loads and grid events,alleviating cabling constraints on battery sizing for home energy systems. I I High productivity.and reliability EnphaseProduces power eveh when the grid is - down* I More than one million cumulative hours of testing Part of the Enphase Energy System, IQ8 Series Microinverters redefine • .Class IIdouble=insulated enclosure I08 Series Microinverters integrate with reliability standards with more than one Optimized for,the latest high-powered the IQ Battery,IQ Gateway,and the million cumulative hours of power-on PV.modules Enphase App monitoring and analysis testing,enabling an industry-leading software. limited warranty of up to 25 years. Microgrid-forming • Complies with the latest advanced grid j j .support j �® Remote automatic updates for the.CERTIFIED ' latest grid requirements Configurable to support_a wide-range of.grid profiles Connect PV modules quickly and easily IQ8 Series Microinverters are UL.Listed to the I08 Series Microinverters that have as PV rapid shutdown equipment and Meets CA Rule 21(UL 1741-SA)and IEEE - integrated MC4 connectors. conforms with various regulations when 1W:' 018(UL 1741=SB) ' installed according to the manufacturer's instructions. NOTE: • IQ8 Microinverters cannot be mixed together with •previous generations of Enphase microinverters (IQ7 Series,IQ6 Series,etc.)in the same system. _ IQ Gateway is required to change•the default •Meets UL 1741 only when Installed with IQ System Controller 2 and 3. •' f profile at the time of Installation tomeet the local I1 Authority Having Jurisdiction(AHJ)requirements. 02023 Enphase Energy.All rights reserved.Enphase,the a and CC logos,IQ and certain other marks listed at httos://enphase.com/trademark-usage-quidelines are trademarks of Enphase Energy,Inc.in the US and other countries. Data subject to change. IQ8MC-MC4-DSH-00049-3.0-EN-US-2023-10-18 a IQBMCMicroinverterINPUT DATA(DC) UNITS r .: Commonly used module paiiings W 260-460 wModule compatibility To meet compatibility,PV modules must be within the following max.input DC voltage and max.module Iu Module compatibility can be checked at https://enphase.com/installers/microinverters/calculator. - - - - -- MPPT voltage range' ..V - -• 25=45 - - - Operating range V 18-58 Min./Max.start voltage- V .22/58 . Max.input DC voltage v -- - 60 - Max.continuous'operating DC.current A.'• Max.input DC short-circuit current A 25 Max.module.) - A -: -- . 20 Overvoltage class DC port II DC port backfeed current mA - 0- PV array configuration Ungrounded array;no additional DC side protection required;AC side protection requires max 20 A per branch circuit OUTPUT DATA CAC) UNITS IQ8MC-72-M-US @240 VAC IQ8MC-72-M-US @208 VAC Peak,outputpower VA' 330 315 " Max.continuous output power VA 320 310 Nominal grid voltage.(L--L) V 240,split=phase(L-L),180° 208,single-phase(L-L),120° -r - -- -- -- - - -- - - ------ --- ------------ --- - - - - - -' - -'- - - --- Min./Max.grid voltage Y v 211-264 183-229 Max.continuous output current 'A 1.33 1.49' Nominal frequency Hz 60 .Extended frequency range' Hz. ' 47-68 AC short circuit fault current over three A 2.70 cycles Max.units per 20 A(L-L).branch circuits. 12 10 - Total harmonic distortion % <5 Overvoltage'classAC port. . AC port backfeed current mA - - 18 Power factor setting Grid-tied power factor(adjustable) 0.85 leading...0.85 lagging Peak efficiency q 97.4. . _ 97.2 CEC weighted efficiency % 97.0 - - - 96.5 -- •- - - - Nighttime power consumption•' mW 33 25 MECHANICAL DATA UNITS Ambient.temperature range. 40`6.to 65°C(-40°F to 149`F). Relative humidity range 4%to 100%(condensing) DC connector type Staubli MC4 - Dimensions(H•W•D);Weight 212 mm MY)•175 mm(6.9").30.2 mm(1.2");1.1 kg(2.43 Ibs) Cooling - - . -Natural'convection-no'fans - Approved for wet locations;Pollution degree Yes;PD3 Enclosure - - - - --- Class II double-insulated;corrosion-resistant polymeric enclosure Environ.category;UV exposure rating NEMA Type 6;outdoor COMPLIANCE CA Rule 21(UL 1741=SA),UL 62109-1;IEEE 1547:2018.()L 1741-8B),FCC Part 15 Class B,ICES-0003 Class B,CAN/CSA-C22.2 NO.107.1-01' Certifications,. " : This product is UL Listed as PV rapid shutdown equipment and conforms with NEC 2014,NEC 2017,NEC 2020;and NEC-2023 section 690.12 and _C22.1-2018 Rule 64-218 rapid shutdown of PV systems for AC and DC conductors when installed according'to the manufacturer's instructions. (1)No enforced DC/AC ratio. (2)Nominal voltage range can be extended beyond nominal if required by the utility. (3)Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. IQ8MC-MC4-DSH-00049-3.0-EN-US-2023-10-18 .ti Revision history REVISION DATE DESCRIPTION DSH-00049-3.0. October2023 Included NEC 2023 specification in the Compliance section. DSH-00049-2.0 I September 2023 I Updated module compatibility information. — DSH-00049-1.0 May2023 Preliminary release. ©2023 Enphase Energy.All rights reserved.Enphase,the a and CC logos,10,and certain other marks listed at https://enphase.com/trademark-usage-quidelines are trademarks of Enphase Energy,Inc.in the US and other countries. Data subject to change. 108MC-MC4-DSH-00049-3.0-EN-US-2023-10-18 .r /,� IRON RIDGE Roof Mount System Built for solar's toughest roofs. IronRidge builds the strongest roof mounting system in solar. Every component has been tested to the limit and proven in extreme environments. Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashings, and is also why our products are fully certified, code compliant and backed by a 20-year warranty. Strength Tested PE Certified All components evaluated for superior ® Pre-stamped engineering letters structural performance. available in most states. Class A Fire Rating Design Software Certified to maintain the fire resistance ® Online tool generates a complete bill of rating of the existing roof. materials in minutes. Integrated Grounding 20 Year Warranty eUL 2703 system eliminates separate Twice the protection offered by module grounding components. competitors. XR Rails XR10 Rail XR100 Rail XR1000 Rail Internal Splices Q + t" z A low-profile mounting rail The ultimate residential A heavyweight mounting All rails use internal splices for regions with light snow. solar mounting rail. rail for commercial projects. for seamless connections. • 6'spanning capability 8'spanning capability 12'spanning capability • Self-tapping screws • Moderate load capability Heavy load capability Extreme load capability • Varying versions for rails • Clear& black anod.finish Clear& black anod.finish Clear anodized finish • Grounding Straps offered Attachments FlashFoot Slotted L-Feet Standoffs Tilt Legs AWL, r T Anchor,flash, and mount Drop-in design for rapid rail Raise flush or tilted Tilt assembly to desired with all-in-one attachments. attachment. systems to various heights. angle, up to 45 degrees. • Ships with all hardware • High-friction serrated face Works with vent flashing • Attaches directly to rail • IBC& IRC compliant • Heavy-duty profile shape Ships pre-assembled Ships with all hardware • Certified with XR Rails • Clear& black anod.finish 4"and 7" Lengths Fixed and adjustable Clamps & Grounding End Clamps Grounding Mid Clamps Q T.Bolt Grounding Lugs Q Accessories I J _ emu �. . LL*f Slide in clamps and secure Attach and ground modules Ground system using the Provide a finished and modules at ends of rails. in the middle of the rail. rail's top slot. organized look for rails. • Mill finish&black anod. • Parallel bonding T-bolt • Easy top-slot mounting • Snap-in Wire Clips • Sizes from 1.22"to 2.3" • Reusable up to 10 times • Eliminates pre-drilling • Perfected End Caps • Optional Under Clamps • Mill&black stainless • Swivels in any direction • UV-protected polymer Free Resources Design Assistant A NABCEP Certified Training Go from rough layout to fully V, Earn free continuing education credits, engineered system. For free. �•, while learning more about our systems. Go to IronRidge.com/rm V Go to lronRidge.com/training owww.ironridge.com :00 ,��_ _ CONTRACTOR ATRI C K WADE . . .. - psc, WER LUTIO S SCOPE OF WORK AHJ UTILITY (N)7.650KW DC ROOF MOUNTED PV SYSTEM TOWN OF SOUTHOLD. LONG ISLAND POWER LONG,IS.LAND POWER (18),HANWAH Q CELL Q.TRON BLK M-G2+425W MODULES VICINITY MAP THORITY SOLUTIONS argiiive Alex Perrone P. I Hr- Gallery � 2060'OCEAN AVENUE . (18) ENPHASE IQ8MC-72-M-US MICROINVERTERS ...,✓ (01) EN HASE IQ COMBINER 4/4C PANEL: Q MA, NY 11779 - - - MocarlgVmeygrds;' ,-� 111 RONKONKO CODES AND STANDARD WITH 6313480001 S I H AMENDMENTS 4 2020 BCNYS PROJECT INFO&ADDRESS 2020 FCNYS 2020 RCNYS_. , as PATRICK WADE . :740 Country Club Or • 1 2017 NEC - � cuict,oyue;:�1935 740 COUNTRY CLUB.DR, ' CUTCHOGUE, Pelle �Jnii J ENVIRONMENTAL h�Y rd�, = �`�, ,'; NY 11936 S ,` . .WIND SPEED: 140 MPH . v.2S, SIZE SYSTEM SI SNOW LOAD: 20 PSF � DC SIZE: 7.650 KW DC-(STC) EXPOSURE CATEGORY: B se n-u wt��.. _�:�_� GENERAL NOTES SHEET INDEX NOTES 1. TO THE BEST OF MY KNOWLEDGE, PROJECT NOTES: PV-1 COVER SHEET JUDGMEN,THE PLANS AND -THIS PHOTOVOLTAIC(PV)SYSTEM SHALL COMPLY WITH PV-2 SITE PLAN-1 SPECIFICATIONS ARE E PV-2.1 SITE PLAN-2 COMPLIANCE WITH THE 2020 THE NATIONAL ELECTRIC CODE(NEC)ARTICLE 690,ALL RESIDENTIAL CODE OF NEW YORK PV-3 ATTACHMENT PLAN STATE. MANUFACTURER'S.LISTING AND INSTALLATION PV-3.1 STRUCTURAL PLAN 2. IT ISA%AoLATIONOF THE LAW FOR INSTRUCTIONS,AND THE RELEVANT CODES AS SPECIFIED PV-4 ELECTRICAL ANY PERSON,UNLESS ACTING BY THE AUTHORITY HAVING JURISDICTION'S (AHJ) METER NO: 98298120 PV-4.1 ELECTRICAL CALCULATIONS UNDER THE DIRECTION OF APPLICABLE CODES. LICENSED PROFESSIONAL,TO PV-5 LABELS ALTER AN ITEM IN ANY WAY.IF AN -THE UTILITY INTERCONNECTION APPLICATION-MUST BE ACCT NO: 9621071403 PV-6 RESOURCE DOCUMENT ITEM BEARING THE SEAL of A APPROVED AND PV SYSTEM INSPECTED PRIOR.TO LICENSED PROFESSIONAL Is PARALLEL OPERATION PV-6.1 RESOURCE DOCUMENT ALTERED,THE ALTERING LICENSED PV-6.2 RESOURCE DOCUMENT PROFESSIONAL SHALL AFFIX TO -GROUND FAULT DETECTION AND INTERRUPTION (GFDI) THEIR ITEM THEIR SEAL AND THE DEVICE IS INTEGRATED WITH THE MICROINVERTER IN PV-6.3 RESOURCE DOCUMENT NOTATION"ALTERED BY" PV-6.4 RESOURCE DOCUMENT FOLLOWED BY THEIR SIGNATURE ACCORDANCE WITH NEC 690.41(B) AND THE DATE OF SUCH -ALL PV SYSTEM COMPONENTS; MODULES, UTILITY- PV-6.5 RESOURCE DOCUMENT ALTERATION,AND ASPECIFIC INTERACTIVE INVERTERS,AND SOURCE CIRCUIT COMBINER PV-6.6 RESOURCE DOCUMENT DESCRIPTION-OF THe.ALTeRAnoN. PV-6.7 RESOURCE DOCUMENT pF<NEyy BOXES ARE IDENTIFIED AND LISTED FOR USE IN PV-6.8 RESOURCE DOCUMENT PHOTOVOLTAIC SYSTEMS AS REQUIRED BY NEC 690.4: PV. P E�WA9p'09 MODULES: UL1703, IEC61730,AND IEC61215,AND NFPA 70 ' ' CLASS C FIRE INVERTERS: UL 1741 CERTIFIED, IEEE 1547, 4_ n 929, 519 COMBINER BOX(ES): UL 1703 OR UL 1741 l p �' m ACCESSORY n MAX DC VOLTAGE CALCULATED USING MANUFACTURER F4 09676 _ PROVIDED TEMP COEFFICIENT FOR VOC. IF UNAVAILABLE, A9�FESSIONPv MAX DC VOLTAGE CALCULATED ACCORDING TO NEC 690.7. -ALL.INVERTERS, PHOTOVOLTAIC MODULES,PHOTOVOLTAIC PANELS;AND SOURCE CIRCUIT COMBINERS INTENDED FOR -DRAWN.BY MP USE IN A PHOTOVOLTAIC POWER SYSTEM WILL BE DATE 2/11/2025 IDENTIFIED AND.LI.STED FOR THE APPLICATION PER 690.4. SHALL BE INSTALLED ACCORDING TO ANY INSTRUCTIONS REVISION FROM LISTING OR LABELING [NEC 110.31. SIGNATURE -ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE. IF EXPOSED TO SUNLIGHT, IT SHALL BE UV PV-1 RESISTANT.ALL PLAQUES AND SIGNAGE WILL BE INSTALLED AS BUILT AS REQUIRED BY-THE NEC AND AHJ. COVER SHEET SCOPE OF WORK TOTAL ROOF SQUARE FOOTAGE IS:2499,07 FTZ GE n M1 r (N)-7.650KW DC,ROOF,MOUNTED PV SYSTEM : jp FOOTAGE IS: 37% COVERED BY SOLAR IS: IT (18) HANWAH'Q CELL Q.TRON BLK M-G2+425W MODULES j SOLUTIONS (18) ENPHASE IQ8MC-72-M-US MICROINVERTERS (01).ENP:HASE_IQ COMBINER 4/4C.PANEL . . . . . LONG ISLAND POWER SOLUTIONS 2060 OCEAN AVENUE RONKONKO MA, NY 11779 - — - - — .(E)POOL 631 348 0001 \ / \ PROJECT INFO&ADDRESS i \ 0 PATRICK WADE 740'COUNTRY CLUB DR, CUTCHOGUE, i \ � NY 11935 SYSTEM SIZE ' DC SIZE: 7.650 KW DC-(ST.C) NOTES 1. TO THE BEST OF MY KNOWLEDGE, BELIEF AND PROFESSIONAL' Q JUDGMENT,THE PLANS AND SPECIFICATIONS ARE IN COMPLIANCE WITH THE 2020 \ RESIDENTIAL CODE OF NEW YORK STATE. 2. IT IS A VIOLATION OF THE LAW FOR 7 ANY PERSON,UNLESS ACTING \ \ UNDER THE DIRECTION OF A LICENSED PROFESSIONAL,TO ALTER AN ITEM IN ANY WAY.IF AN \ \ ITEM BEARING THE SEAL OF A LICENSED PROFESSIONAL IS ALTERED,THE ALTERING LICENSED PROFESSIONAL SHALL AFFIX TO THEIR ITEM THEIR SEAL AND THE \ NOTATION"ALTERED o FOLLOWED BY THEIR SIGNATURE ` AND THE DATE OF SUCH ALTERATION,AND SPECIFIC It DESCRIPTION-OF THE ALTERATION. 0 � I. LEGEND $$.9 (� �? =FIRE PATHWAYS / l �p� �p � 9676 ,.vet•=: ° .9�FESSIO�P- PROPERTY LINE �� -FENCE D� DRAWN BY MP SKYLIGHT/CHIMNEY �^ � DATE 2/11/2025 O El VENT/OBSTRUCTION �� �V R` � REVISION G OU " SIGNATURE SITE PLAN-1 Pv-2 SCALE:1/32" = 1'-011 AS BUILT, SITE PLANA CONTRACTOR SCOPE OF WORK... . TOTAL ROOF SQUARE FOOTAGE IS: 2499.0TF7 (N) 7.650KW DC ROOF MOUNTED PV SYSTEM _ NEW ARRAY SQUARE FOOTAGE IS: 378.35 FT?' COV . .(18) HANWAH Q CELL Q.TRON BLK M-G2+425W MODULES 5 4% .� o � UTION (18) ENPHASE IQ8MC-72-M=US MICROINVERTERS ' . S (01) ENPHASE IQ COMBINER 4/4C PANEL • LONG ISLAND POWER SOLUTIONS 2060 OCEAN AVENUE - . RONKONKO MA, NY 11779 - 631 348 0001 PROJECT INFO&ADDRESS �Q PATRICK WADE 3 . 740'COUNTRY CLUB.DR, (N)(18)HANWAH Q CELL Q.TRON BLK M-G2+ CUTCHOGUE, 425W MODULES WITH ENPHASE IQ8MC-72-M-US NY 11936 MICROINVERTERS UNDER EACH MODULE(240V) SYSTEM SIZE DC SIZE: 7.650 KW DC-(STC) NOTES ' 1. TO THE BEST OF MY KNOWLEDGE, O `�� BELIEF AND PROFESSIONAL �� LADDER ACCESS JUDGMENT,THE PLANS AND SPECIFICATIONS ARE IN � COMPLIANCE WITH THE 2020 RESIDENTIAL CODE OF NEW YORK STATE. 2. IT IS A VIOLATION OF THE LAW FOR W �0 ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL,TO ALTER AN ITEM IN ANY WAY.IF AN ITEM BEARING THE SEAL OF A �v LICENSED PROFESSIONAL IS LADDER ACCESS O ALTERED,THE ALTERING LICENSED PROFESSIONAL SHALL AFFIX TO THEIR ITEM THEIR SEAL AND THE NOTATION"ALTERED BY FOLLOWED BY THEIR SIGNATURE AND THE DATE OF SUCH ALTERATION,AND A SPECIFIC DESCRIPTION OF THE ALTERATION. (N)ENPHASE IQ COMBINER 414C WITH ENPHASE IQ GATEWAY ��� �``� P �,Epwg9�'O•p (OUTSIDE HOUSE) cr (N)VISIBLE LOCKABLE LABELED LEGEND AND FUSED AC DISCONNECT FIRE PATHWAYS (UTILITY DISCONNECT) ` `� � 2 ® (OUTSIDE HOUSE) O ���0 PROPERTY LINE 'O9pF ONP` ESSI,. 0 --'FENCE ® SKYLIGHT/CHIMNEY (E)UTILITY METER DRAWN BY MP O 0 VENT/OBSTRUCTION (UNDERGROUND SERVICE) (N)JUNCTION BOX (OUTSIDE HOUSE) NEMA4X RATED DATE 2/11/2025 (E)MAIN SERVICE PANEL (N)CONDUIT RUN REVISION (INSIDE BASEMENT) SIGNATURE SITE PLAN-2 PV-2.1 SCALE:3/32" = V-0" AS BUILT SITE PLAN-2 'CONTRACTOR' '. � 'ROOF SECTION(S) :. . ROOF MATERIAL -1--�•-0--.--=- --- IIIIIIIIII$'IIIIIIIIIII IIIIIIIIIIiIii IIIIIIIIIIII . . IIIIIIIIII r E F- D-u u9S- NWr6S "7. EIrCOMPOSITE SHINGLE ROOF1 RAFTER SIZE-2"X8" O.C. SPACING- 16" MODULES=16 LONG ISLAND POWER OWER ROOF MATERIAL- SOLUTIONS COMPOSITE SHINGLE ROOF 2 2060 OCEAN AVENUE * - '. RAFTERSIZE-2„X8 RONKONKOMA, NY 117 .: : 7. �. 9O.C. SPACING-16" MODULES-2 631 3480001 I I PROJECT NFO&ADDRESSN CLAMP AL PATRICK WADE IRONRIDGE FLASHFOOT 2 740 COUNTRY CLUB DR, CUTCHOGUE,i0 NY 11935IRONRIDGE XR-100 RAIL SYSTEM SIZE - RAFTER I I DC SIZE: 7.650 KW DC-(STC) '-0 1� NOTES 54 TOTAL MOUNT 10 31 9 7. TO THE BEST OF MY KNOWLEDGE, BELIEF AND PROFESSIONAL JUDGMENT,THE PLANS AND ARRAY 1 SPECIFICATIONS ARE IN COMPLIANCE WITH THE 2020 TILT- 16 DEG RESIDENTIAL CODE OF NEW YORK AZIMUTH - 330 DEG 2. IT IS A VIOLATION OF THE LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OF A PROFESSIONAL,LICENSED ALTER AN ITEM N ANY WAY.IF AN ITEM BEARING THE SEAL OF A LICENSED PROFESSIONAL IS ALTERED,THE ALTERING LICENSED PROFESSIONAL SHALL AFFIX TO THEIR ITEM THEIR SEAL AND THE NOTATION"ALTERED BY" FOLLOWED BY THEIR SIGNATURE AND THE DATE OF SUCH ALTERATION,AND A SPECIFIC DESCRIPTION OF THE ALTERATION.. � q co 17 2 6 DRAWN,BY MP DATE 2/11/2025$1-3 5 4,-3" REVISION 4, ARRAY2 SIGNATURE TILT- 14"DEG PV-ao ATTACHMENT PLAN AZIMUTH - 240 DEG AS BUILT ATTACHMENT PLAN . CONTRACTORS . . ;. OWER �. ' LONG ISLAND POWER SOLUTIONS- 2060 OCEAN AVENUE MODULE RONKONKOMA, NY 11779. BOTTOM MOUNTING CLIP . CLAMP W -!" 'BOLT WASHER 631 348 000 1 AND LOCK WASHER PROJECT INFO&ADDRESS PATRICK WADE 740 COUNTRY CLUB DR, MODULE i CUTCHOGUE, NY 11936 IRONRIDGE XR-100 RAIL / / / / SYSTEM SIZE DC SIZE: 7.650 KW.DC-(STC) 3i BOLT NOTES j / 1. TO THE BEST OF MY KNOWLEDGE, (E) COMPOSITE SHINGLE BELIEF AND PROFESSIONAL JUDGMENT,THE PLANS AND / SPECIFICATIONS ARE IN / COMPLIANCE WITH THE 2020 RESIDENTIAL CODE OF NEW YORK IRONRIDGE FLASHFOOT2 STATE. 2. IT IS A VIOLATION OF THE LAW FOR ANY PERSON,UNLESS ACTING 5/16" x 5'' STAINLESS STEEL DIA LAG UNDER THE DIRECTION OFA LICENSED PROFESSIONAL,TO FLASHING ALTER AN ITEM IN ANY WAY.IF AN ITEM BEARING THE SEAL OF A BOLTS MIN. 2.5" EMBEDMENT LICENSED PROFESSIONAL IS ALTERED,.THE ALTERING LICENSED PROFESSIONAL SHALL AFFIX TO THEIR ITEM THEIR SEAL AND THE NOTATION."ALTERED BY" FOLLOWED BY THEIR SIGNATURE AND THE DATE OF SUCH ALTERATION,AND A SPECIFIC DESCRIPTION_OF THE ALTERATION. �CF NF �,EDWA"y0 ` r. l L, y . ,r 2 ti E f N �FOp9876 �: (E) RAFTER 211 X8n @ 1611 O.C. 9�FESS1NPv 2 DRAWN BY MP DATE 2/11/2025 psc REVISION SIGNATURE 1 STRUCTURAL PLAN PV-3.1 SCALE:NTS AS BUILT . STRUCTURAL PLAN SOLAR MODULE SPECIFICATIONS INVERTER SPECIFICATIONS NOTE: 1 HANWAH'Q-CELL Q.TRON.BLK ENPHASE]Q8MC-72-W-US OW MANUFACTURER/MODEL.# MANUFACTURER/.MODEL# - - ALL CONDUCTORS ARE COPPER UNLESS OTHERWISE ER M-G2+425W MICROINVERTER X4, psc, VMP 32.98V. MIN/MAX DC VOLT RATING 22V.MIN/58V MAX NOTED IMP 12.88A POWER 460W MAX INPUT VOC 38.67V NOMINAL AC VOLTAGE RATING 240V/21.1=264V LONG ISLAND POWER ISC 13.49A SOLUTIONS MAX.AC CURRENT. 1.33A MAX MODULES PER STRING 12 SINGLE.PHASE TEMP.'COEFF:VOC, 0.24%7K _ 2060 OCEAN VENUE M R N 981 MA, NY 11779 . . . MODULE DIMENSION 67.811 x 44.6"W x 1.18"D (In Inch) MAX OUTPUT POWER . - 320-VA - ETE O:_982 20 RONKONKO 3 1 6 1 348.000 ACCT NO: 96210.71403 TO UTILITY GRID PROJECT INFO&ADDRESS - (N) (1) ENPHASE IQ COMBINER4/4C L1 L2 N. PATRICK WADE . . (N) (18) HANWAH.Q CELL Q.TRON BILK M=G2+ 425W MODULES WITH.ENPHASE IQ GATEWAY, N CLUB . .(2).20A/240VAC CIRCUIT , LIE - 740 COUNTRY CL DR (E) BI-DIRECTIONAL UTILITY CUTCHOGUE BREAKERS 125A RATED (N) (1)AC DISCONNECT:. METER 1-PHASE, 3-W, ' 9,MICROINVERTERS IN BRANCH CIRCUIT 4 (OUTSIDE HOUSE) VISIBLE, LOCKABLE; LABELED M 120V%240V; 200A RATED NY.11935 (2>#12 Q CABLES 60A,FUSED, (2) 30A FUSES, 240V LOAD (UNDERGROUND SERVICE) NEMA 3R, UL LISTED. (OUTSIDE HOUSE) 50 KW SYSTEM SIZE IQ GATEWAY DC SIZE: 7.6 DC-(STC) PER.MANUFACTURER (UTILITY DISCONNECT) SPECIFICATIONS,EITHER WIRELESS (OUTSIDE HOUSE) 10A OR 15A OR 20A Comms - - ,� I L1 L1 NOTES / / / BREAKER Is SUPPLY SIDE TAP �—— _ �— — 1. TO THE BEST OF MY KNOWLEDGE, ——— � SUITABLE FOR USE L2 L2 il BELIEF AND PROFESSIONAL (N)(1)JUNCTION 15A/2P N —G JUDGMENT,THE PLANS AND BOX 600V,NEMA 4X ^ G (E) MAIN BREAKER TO SPECIFICATIONS ARE IN y COMPLIANCE WITH THE 2020 . 9 MICROINVERTERS IN BRANCH CIRCUIT 2 I RATED -—� LINE I I HOUSE 240 V,2OOA/2P RESIDENTIAL CODE OF NEW YORK L1 2�\P I s (TOP.FED) STATE. I I a I 2. IT IS A VIOLATION OF THE LAW FOR . . I I I (E) MAIN SERVICE PANEL ANY PERSON,UNLESS ACTING. I Lz I 200A RATED,240V UNDER THE DIRECTION OF A I I I I I o LICENSED PROFESSIONAL,TO. (INSIDE BASEMENT) ALTER AN ITEM IN ANY WAY.IF AN I I I I I I I o ITEM BEARING THE SEAL OF A ti ti ti I 2 A\P I I I I � LINE SIDE LICENSED PROFESSIONAL IS L1 ALTERED,THE ALTERING LICENSED L2. I I I o f INTERCONNECTION PROFESSIONAL SHALL AFFIX TO LOAD I o AT MAIN SERVICE PANEL THEIR ITEM THEIR SEAL AND THE PER ART. Z05.1`2 A NOTATION"ALTERED BY" N 18 ENPHASE IQ8MC-72-M-US I I I I I N ( ) FOLLOWED BY THEIR SIGNATURE ( ) ( ) I AND THE DATE OF SUCH. MICROINVERTERS ONE UNDER I I I ALTERATION,AND ASPECIFIC EACH MODULE(240V) I I — — — J L G DESCRIPTION OF THE ALTERATION. N I o NE I GEC 'C — J EXISTING GROUNDING KP vDW A9`\ O G G _I— ELECTRODE SYSTEM 1 TO EARTH REF. NEC 250.52, 250.53(A) FO 079676' . <tr� R'> '09pFESS10N�v{' DRAWN BY MP PHASE CONDUCTOR QTY,SIZE AND TYPE GROUND CONDUCTOR QTY„SIZE CONDUIT CONDUIT ID NEUTRAL QTY,SIZE AND TYPE PER CONDUIT DATE 2/11/2025 PER CONDUIT AND TYPE PER CONDUIT SIZE TYPE REVISION 1 2 AWG#12 Q-CABLE NA NA NA 1 AWG#6 BARE,COPPERjEGC N/A FREE AIR SIGNATURE. 2 4 AWG#12 THWN-2,COPPER NA NA NA 1 AWG#10 THWN-2,COPPE 1" PVC. AS, BU I LT PV-4 3 2 AWG#6 THWN-2,COPPER 1 AWG#6 THWN-2,COPPER 1 AWG#6 THWN-2,COPPE 1" PVC 4 2 AWG#6 THWN-2,COPPER 1 AWG#6 THWN-2,COPPER 1 AWG#6 THWN-2,COPPE 1" PVC ELECTRICAL . .. . .. -,CONTRACTOR . - .AMBIENT TEMPERATURE SPECS. OW . r -ER RECORD LOW TEMP -150 LOTIONS PERCENT OF NUMBER OF CURRENT. AMBIENT TEMP (HIGH TEMP 2%) 31 VALUES CARRYING CONDUCTORS IN CONDUIT CONDUIT HEIGHT. 7/8" LONG ISLAND POWER 80 - 4-6 SOLUTIONS ROOF TOP TEMP 530 2060 OCEAN AVENUE .70 7-9 CONDUCTOR TEMPERATURE RATE 750 RONKONKOMA, NY 11779 .50 10-20 631 348 0001 MODULE TEMPERATURE COEFFICIENT OF Voc -0.24%/K PROJECT INFO&ADDRESS . .PATRICK WADE CALCULATIONS: 740 COUNTRY CLUB DR, CUTCHOGUE, NY 11936 1. CURRENT CARRYING CONDUCTOR 2. PV OVER CURRENT PROTECTION ...NEC 690.9(B) SYSTEM SIZE = TOTAL INVERTER O/P CURRENT x 1.25 DC SIZE: 7.650 KW DC-(STC) (A) BEFORE IQ COMBINER PANEL = (18 x 1.33) x 1.25 — 29.93 A AMBIENT TEMPERATURE - (31)OC -...NEC 310.15(B)(2)(a) NOTES ( )( )( ) 1. TO THE BEST OF MY KNOWLEDGE, TEMPERATURE DERATE FACTOR - 0.94 ...NEC 310.15 B 2 a BELIEF AND PROFESSIONAL JUDGMENT,THE PLANS AND GROUPING FACTOR - 0.8...NEC 310.15(B)(3)(a) SPECIFICATIONS ARE IN COMPLIANCE WITH THE 2020 RESIDENTIAL CODE OF NEW YORK STATE. CONDUCTOR AMPACITY 2. IT IS A VIOLATION OF THE LAW FOR Q ANY PERSON,UNLESS ACTING = (INV O/P CURRENT ) x 1.25 / A.T.F / G.F ...NEC 690.8(B) UNDER THE DIRECTION OF A Q LICENSED PROFESSIONAL,TO = [(9 x 1.33) x 1.25] / [0.94 x 0.8] ALTER AN ITEM IN ANY WAY.IF AN ITEM BEARING THE SEAL OF A = 19.90A LICENSED PROFESSIONAL IS ALTERED,THE ALTERING LICENSED PROFESSIONAL SHALL AFFIX TO SELECTED CONDUCTOR - #12 THWN-2 ...NEC 310.15(B)(16) THEIR ITEM THEIR SEAL AND THE NOTATION"ALTERED BY" FOLLOWED BY THEIR SIGNATURE AND THE DATE OF SUCH ALTERATION,AND A SPECIFIC (B) AFTER IQ COMBINER PANEL DESCRIPTION-OF THE ALTERATION. TEMPERATURE DERATE FACTOR - 0.94 -or TEMPERATURE Y. w: GROUPING FACTOR - 1 co P CONDUCTOR AMPACITY = TOTAL INV O/P CURRE T x 1.25 / 0 4( N ) .9 / 1 ...NEC 690.8(B) _ [(18 x 1.33) x 1.251 / [0.94 x 11 oA °79s76 .9�FESSIONP = 31.84 A -- -_ DRAWN BY MP SELECTED CONDUCTOR - #6 THWN-2 ...NEC 310.15(B)(16) DATE 2/11/2025 REVISION SIGNATURE PV-4.1 A& BUILT ELECTRICAL CALCULATIONS CONTRACTOR ❑1 ;,.. �OWER I WARNING TIISOLUTIONS $ ELECTRIC SHOCK HAZARD ❑ CAUTION _ - IF A GROUND GROUNDED INDICATED- POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE NORMALLY GROUNDED CONDUCTORS POWER MAY.BE UNGROUNDED AND ENERGIZED K R PV SYSTEM EQ:UiI E=D FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: LONG ISLAND POITH RAPID SHUTDOWN SOLUTIONS 2 ' TURN RAPID SHUTDOWN 2060 OCEAN AVENUE WARNING 9 SWITCH TOTHE RONKONKOMA, NY 11779 ❑ "OFF"POSITION TO. so as c zoo • SHUTDOWN PV SYSTM <P1°""�`� O 6313480001. ELECTRIC SHOCK HAZARD: AND REDUCE SHOCK HA' THE DC CONDUCTORS OF THIS IN THE ARRAY PHOTOVOLTAIC SYSTEM ARE UNGROUNDED L� PROJECT INFO&ADDRESS AND MAY BE ENERGIZED PATRICK WADE PV ARRAY 740 COUNTRY CLUB DR, 3 WARNING 1 J CUTCHOGUE, ❑ NY 11935 ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS SYSTEM SIZE TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED RATED� • 94AMPS DC SIZE: 7.650 KW DC-(STC) IN THE OPEN POSITION 11NOMINAL OPERATING 4 NOTES 4WARNING-Electric Shock - 1. TO THE BEST OFBELIEF AND PRO ESSIONALEDGE, No user serviceable parts inside COMBINER PANEL . O� JUDGMENT,THE PLANS AND (OUTSIDE HOUSE) ,`Q� SPECIFICATIONS ARE IN PV DISCONNECT COMPLIANCE WITH THE 2020 (OUTSIDE HOUSE) _f GV RESIDENTIAL CODE OF NEW YORK ❑ I �� Q'l STATE. 2: IT IS A VIOLATION OF THE LAW FOR ANY PERSON,UNLESS ACTING UTILITY METER V UNDER THE DIRECTION OF A 6WARNING: (UNDERGROUND SERVICE) LICENSED PROFESSIONAL,TO (OUTSIDE HOUSE) ALTER AN ITEM IN ANY WAY.IF AN AS BUILT MAW BASEMENT)SERVICE PANEL ITEM BEARING THE SEAL OF A POWERO (INSIDE LICENSED PROFESSIONAL ISALTERED,THE ALTERING LICENSED PROFESSIONAL SHALL AFFIX TO WARNING THEIR ITEM THEIR SEAL AND THE F7 INVERTER OUTPUT CONNECTION • .O NOT NOTATION"ALTERED BY" FOLLOWED BY THEIR SIGNATURE RELOCATE THIS OVERCURRENT DEVICE AND THE DATE OF SUCH ALTERATION,AND A SPECIFIC DESCRIPTION OF THE ALTERATION. Solar Module Solar Module Main Service � W Micro Inverters IQ COMBINER AC DISCONNECT Panel /P� EOWq y0 AC Junction Box 6 Outside Door ��f Outside Door 3,9,10 1 3,4 3,6,8,9,11 2 Inside Door Inside Door 5,6,7 ";,FOA 079676 ��I` OEM Cables should be marked by the manufacturer 5'6'7 *Custom 90ESSIDNP�, NEC 690.31(G)(3) NEC 690.13(B) Directory NEC 690.54 DRAWN BY MP NEC 690.56(C) Placard DATE 2/11/2025 NEC 705.12(B)(3) NEC 690.13(B) NEC 705.12(B)(2)(3)(b) NEC 690.13(B) REVISION NEC 690,56(B) NEC 705.12(B)(3) NEC 690.56(B) SIGNATURE NEC 705.10 NEC 705.10 NEC 705.12(B)(2)(3)(b) PV-5 NEC 705.12(B)(3) LABELS