Loading...
HomeMy WebLinkAbout52116-Z TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 52116 Date: 07/18/2025 Permission is hereby granted to: Anthony F Naglieri 9 Rodney St Port Jefferson Sta, NY 11766 To: construct a single-family dwelling as applied for per SCHD approval. Premises Located at: 1000 Fleetwood Rd, Cutchogue, NY 11935 SCTM# 137.-5-8 Pursuant to application dated 11/06/2024 and approved by the Building Inspector. To expire on 07/18/2027. Contractors: Required Inspections: Fees: Single Family Dwelling-NEW $3,779.63 CO- RESIDENTIAL $100.00 Total 93,879.63 L Uilding Inspector urci;oy TOWN OF SOUTHOLD —BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 • Telephone (631) 765-1802 Fax (631) 765-9502 htt s://www.southoldtowmiv.gov Date Received APPLICATION FOR BUILDING PERMIT 4 For Office Use Only ti PERMIT N0,-5� Building Inspector: �° K" ApaClctins and;ftarmahst, flled ,ia inleirltiret .ir�cnplet p i tia r61N ra t be cept , ,;iN r th #pp lito l ndttbe a n a a plrrip ote Date:8-6-2024 OWNEA0 00V""'40ERTy: Name:Anthony & Patricia Nagher TM 000-137-5-8 Project Address: 1000 Fleetwood Rd, Cutchogue NY 11935 Phone : Email: Mailing Address: r" Name:Jonathan Grano Mailing Address:850 Lincoln Ave, Suite 10 , Bohemia NY 11716 Phone :631- 41761 n Email:Jon @ jgranocontractng.com DES,NJP PFESSNCNI��114 0 l� 011�9w Name: Mailing Address: Phone : Email: CONTRACTOR,,INFQRIVIATIO,N , Name:North Fork Building Company Mailing Address:850 Lincoln Ave, Suite 10, Bohemia NY 11716 Phone :631-708 107 Emall:Jon@ northtorkhuildingcompany.com ;:; ft ®New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: ❑Other Will the lot be re-graded? R'Yes ❑No Will excess fill be removed from premises? ❑Yes ®No 1 PROPERTY INFORMATION Existing use of property: Residential Intended use of property: Residential Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to R-40 this property? ❑Yes ®No IF YES, PROVIDE A COPY. �, +� `p!g,, Mr" �IrMg., "� �an�r/��►ntw��tPr�adesi � n�uf��sl�aa1 I� sgpo�i��� �rr a9); ral� ��: rid�t�"b�r��+rr I�s��s a�p�rvlsl�c��a�r a t r ft ,T�xw n d w xl� 4ti iW i R bl t �kh pu,iCding G artrnweut° r x issu ooaa r IldloS rWtpursq�in t ull Ck in pri . T� �ra� �x�I�ol+ ��ai� o�ur� +"r t���rr�"�rk arrtl�th�r ap�iiwl+� s,Cir�ir���tis o� eg�ul��][rt��s���or 'o �rostnrctlo�a t�f ?�ildir� � a i l rs; ill- wti�r�ts'nr f+r� r�%orrtul rror`d± oiit r s orei psccik ,fide appl6 nt a egis two p,y',w all 4pq iG apal lags, } � I lrr , housin�'crad�ar��or+��rulatians�rlst tcw,�t9w�it pukhorii�d�osp �tor�vas pr�rnwis�s arr�d tin bulldNng�s�fog"�rpc+�ss�ry i�sle�tios"ais+e:s � �rats � i� bl�alr� punishsbl0as* ussrA iisiem ainarp4fsO 6 ItoSattl tw 10A '9fthedieYuri:StagfienaIlam: Application Submitted By(print n e): Al 0�' El Authorized Agent i9owner Signature of Applicant: Date: STATE OF NEW YORK) SS: COUNTYOF �.? )IL ) 1(�A """" being duly sworn, deposes and says that(s)he is the applicant (Name of incllAual signing contract)above named, (S)he is the (Contractor,Agent, Corporate Officer,etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this a day of 0C\-Q\11 e�r , 20 zu Notary P STATE �,,. ,'"OF NEW Y RK. �? E PUBLIC PROPERTY OWNER AUTHORIZATION ` (Where the applicant is not the owner) I, residing at do hereby authorize to apply on my behalf to the Town of Southold Building Department for approval as described herein.. Owner's Signature Date Print Owner's Name 2 q 7 J L N0 14— NAGLIERI RESIDENCE ` Tx Fu.- ,. . ..... cI I P"'HUGL7I Nr.W YQazK I R- RA C2 SUFFOLK ouN-Tv DEa ART EW O) HEALTH SERVICE .:Ge t z sue_Isy:s IER b0RAPPROVAL OF CORImIGN FoR AWWM- C�v ,,_ SINGLE F MIL"RESIDENCE ONLY I DA $ 6/25/2024 REF_ G. R-24-0788 i _ € APPROV FOR MAxtmum 0 A epees V s EXPIRES THREE YEARS FROM DATE OFAPPRC)ttA_ O I - E E CAL'0." q— ec` w''ca.lc�l ALL ELECTEIr E rmrrl TO r•. _ FORMED N Aa�YOA EE - "I NET LI '' x I ' � - C@RAGI IN TlI�AJSW #-FuJ IC19.n USA ,_..,,,,".h +F I sm � .. I IuiTJIYMtlNS .IAIIUtt.NYli. t.y �x ...4 I � Wl1liH11A➢➢IU.� I I I IUILIIUL� ➢I Fj I t `- 4 u wv a M1` Y �, unV IJrun aW VVVunu t PROPOSED r RESIDENCE ,.�r � I 0 LJ I= NAGLIERI u oo IY. RESIDENCE IOOO Fl FK'lll00ll I(uVl Iw I'l 11'('1101 Ell. N) I I Id:. 1 ` 9 Ic. c, SOWN I Y}II 1uoll, ._# J12 _ ` ovAnc Yrax. SITE MAP e ®PROPOSED SITE PLAN x III> -:,YI Flo�oA�E ffE�� I" ..,A SAY SAY amk e 4.= - — ICI nlr:,war SCH D-1 Generated by REScheck-Web Software Compliance Certificate Project Naglieri Residence Energy Code: 2018 IECC Location: Cutchogue, New York Construction Type: Single-family Project Type: New Construction Orientation: Bldg. faces 0 deg. from North Conditioned Floor Area, 4,038 ft2 Glazing Area 19% Climate Zone: 4 (5572 HDD) Permit Date: Permit Number: All Electric false Is Renewable false Has Charger true Has Battery: false Has Heat Pump: true Construction Site: Owner/Agent: Designer/Contractor: 1000 Fleetwood Road Anthony Naglieri Michael Dunn Cutchogue, New York 11935 9 Rodney Street Michael Dunn Architect Port Jefferson Station, New York 256 Orinoco Drive 11776 Suite B 631-335-7923 Brightwaters, New York 11718 tonynags@hotmail.com 646-448-8997 Mike.mkdarchitect@gmail.com Compliance: 20.7%Better Than Code Maximum UA: 488 Your UA: 387 Maximum SHGC: 0.40 Your SHGC: 0.40 The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules, It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Slab-on-grade tradeoffs are no longer considered in the UA or performance compliance path in REScheck. Each slab-on-grade assembly in the specified climate zone must meet the minimum energy code insulation R-value and depth requirements. Envelo e As ae Li Gross Area Cavity Cont. Prop. Req. Prop. Req. Assembly or Perimeter Flat Ceiling: Flat Ceiling or Scissor Truss 1,893 49.0 0.0 0.026 0.026 49 49 South Wall:Wood Frame, 16" D.C. 642 15.0 10.0 0.042 0.060 19 27 Orientation: Back Door: Glass Door(over 50%glazing) SHGC: 0.40 160 0.300 0.320 48 51 Orientation: Back Window:Wood Frame SHGC: 0.40 38 0.300 0.320 11 12 Orientation: Back Project Title: Naglieri Residence Report date: 07/16/24 Data filename: Page 1 of10 x Gross Area Cont. 1Prop. 1 Assembly 1 1 1 Perimeter North Wall:Wood Frame, 16"o.c. 642 15.0 10.0 0.042 0.060 20 29 Orientation: Front Door: Glass Door(over 50%glazing) SHGC: 0.40 40 0.300 0.320 12 13 Orientation: Front Window:Wood Frame SHGC: 0.40 120 0.300 0.320 36 38 Orientation: Front East Wall:Wood Frame, 16"o.c. 300 15.0 10.0 0.042 0.060 11 16 Orientation: Left side Door: Glass Door(over 50%glazing) SHGC: 0.40 20 0.300 0.320 6 6 Orientation: Left side Window:Wood Frame SHGC: 0.40 11 0.300 0.320 3 4 Orientation: Left side West Wall:Wood Frame, 16" o.c. 300 15.0 10.0 0.042 0.060 10 15 Orientation: Right side Door: Glass Door(over 50%glazing) SHGC: 0.40 20 0.300 0.320 6 6 Orientation: Right side Window:Wood Frame SHGC: 0.40 34 0.300 0.320 10 11 Orientation: Right side South Wall Second Floor:Wood Frame, 16"o.c. 395 15.0 10.0 0.042 0.060 15 22 Orientation: Back Window:Wood Frame SHGC: 0.40 27 0.300 0.320 8 9 Orientation: Back North Wall Second Floor:Wood Frame, 16"o.c. 395 15.0 10.0 0.042 0.060 12 18 Orientation: Front Door: Glass Door(over 50%glazing) SHGC: 0.40 20 0.300 0.320 6 6 Orientation: Front Window: Wood Frame SHGC: 0.40 81 0.300 0.320 24 26 Orientation: Front East Wall Second Floor:Wood Frame, 16"o.c. 265 15.0 10.0 0.042 0.060 11 15 Orientation: Left side Window: Wood Frame SHGC: 0.40 14 0.300 0.320 4 4 Orientation: Left side West Wall Second Floor:Wood Frame, 16"o.c. 265 15.0 10.0 0.042 0.060 10 14 Orientation: Right side Window: Wood Frame SHGC: 0.40 24 0.300 0.320 7 8 Orientation: Right side Floor:All-Wood joist/Truss 1,893 38.0 0.0 0.026 0.047 49 89 Compliance Statement. The proposed building design described here is coned he building plans,specifications,and other calculations submitted with the permit application.The proposed buildin to meet the 2018 IECC requirements in REScheck Version : REScheck-Web and to comply with the mandatory TY6 e REScheck Inspection Checklist. Michael Dunn 7-2-2024 Name-Title Sign ur'e Date Project Title: Naglieri Residence Report date: 07/16/24 Data filename: Page 2 of 10 . p ,EScheck Software Version -, REScheck-Web Inspection Checklist. Energy Code: 2018 IECC Requirements: 100.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the RE acheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed.Where compliance is itemized in a separate table, a reference to that table is provided. Section Plans Verified Field Verified # Pre-inspection/Plan Review Value Value Complies? Comments/Assumptions &Reg.ID _ _........ 103.1, Construction drawings _ „. . ,_, ._����� . �o . ti.��,,, ._.._....._... _ uir m� g and �C�Complles ;Requirement will be met. 103.2 Aocumentation demonstrate -,i Does Not [PRl]1 energy code compliance for the ❑Not Observable building envelope.Thermal envelope represented on hiNot Applicable construction documents. �wow ........... .. 103.11 Construction drawings and EComplies ;Requirement will be met. 103.2, documentation demonstrate ❑Does Not 403.7 j energy code compliance for [PR311 lighting and mechanical systems. ❑Not Observable �q Systems serving multiple ❑Not Applicable dwelling units must demonstrate compliance with the IECC Commercial Provisions. 302.1, Heating and cooling equipment is Heating: Heati ng: E1Complies Requirement will be met. 4033 sized per ACCA Manual S based Btu/hr Btu/hr ,❑Does Not [PR2)2 on loads calculated per ACCA Cooling: Cooling: ❑Not Observable Manual J or other methods Btu/hr Btu/hr approved by the code official. !❑Not Applicable Additional Comments/Assumptions: �1g Impact t(Tier 2) 3 Low Impact(Tier 3) Hi h Im act(Tier 1) 2 Medium Impact Project Title: Naglieri Residence Report date: 07/16/24 Data filename: Page 3 of10 Section Foundation inspection Complies? Comments/Assumptions & Req.ID _ _ protect e g s le to ODoespNot Requirement will.be.m.... � _.� � u .. _........ � .� �A protective covering is installed . � � et. p exposed exterior insulation and dextends a minimum of 6 in. below 'Vo Not Observable jn ..VNot Applicable ....--. .�, ....._ ..._..� .._� 41 . Snow-and ice-melting system controls Z IComplies Exception: Requirement is not applicable. '(FO1212 installed. boes Not ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: i ligi�impact (Tier 1) 2 Medium Impact(Twer 2) 3 Low impact(Tier 3) Project Title: Naglieri Residence Report date: 07/16/24 Data filename: Page 4 of10 Section Plans Verified Field Verified L # Framing/ Rough-In Inspection! Value Value Complies? Comments/Assumptions & Reg.ID _ _ _ 402.1.1, averageU- r(area-weighted �-.___ . U-�` lCoespNot table for alules Envelope m T Glazing facto g - Assemblies ElD 402.3.3, 402.5 []Not Observable I [FR2]1 ❑Not Applicable . .1.3 - .. ...�...... .ww.._ _. U-factors of fenestration products" ❑Complies Requirement will be met. [FR4]1 are determined in accordance ❑Does Not with the NFRC test procedure or taken from the default table. ❑Not Observable ❑Not Applicable j 402.4.1.1 ,Air barrier and t _-hermal barrier ❑Comiplles ;Requirement will be met. [FR23]1 installed per manufacturer's ❑Does Not instructions. ❑Not Observable ' ❑Not Applicable E 402.4.3 ''Fenestration labeled a s meeting site built s l W pw amm mmmm m VONw� �DoespNot Requirement will be met. AAMA/WDMA/CSA 101/I.S.2/A440 r ❑Not Observable or has infiltration rates per NFRC 400 that do not exceed code ❑Not Applicable limits. w,. , ... ..... 402.4.5 IC-rated recessed lighting fixtures ;❑Complies ;Requirement will be met. [FR16]2 sealed at housing/interior finish ❑Does Not and labeled to indicate:52.0 cfm ❑Not Observable leakage at 75 Pa. ❑Not Applicable 1 Supply and return ducts in attics ❑Complies Exception: Ducts located [FR12]1 insulated >= R-8 where duct is '❑Does Not °`completely inside the >= 3 inches in diameter and >_ -]Not Observable building envelope. ;R-6 where< 3 inches.Supply and, return ducts in other portions of ❑Not Applicable ,the building insulated >= R-6 for ,diameter>= 3 inches and R-4.2 for< 3 inches in diameter. 403.3.2 ,Ducts, air handlers and filter 7, ;❑Complies ;Requirement will be met. [FR13]1 boxes are sealed with ❑Does Not !joints/seams compliant with �� , ;International Mechanical Code or ❑Not Observable International Residential Code, as ❑Not Applicable applicable. _. 403.3.5 Building cavities are not used as ❑Com p ilies Requirement will be met. [FR15]3 ducts or plenums. ❑Does Not []Not Observable ❑Not Applicable !403.3.6(1, Ducts partially or completely ❑Complies Requirement will be met. 2) buried in ceiling insulation have -]Does Not [FR26]3 an insulation R-value not less ❑Not Observable than R-8,the sum of the ceiling insulation R-value against and ❑Not Applicable j above the top of the duct, and against and below the bottom of the duct, is >=than R-19, excluding the R-value of the duct insulation. 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Naglieri Residence Report date: 07/16/24 Data filename: Page 5 of10 Sec lean � Plans Verified Field Verified # Framing/ Rough-In Inspection Value Value Complies? Comments/Assumptions & ID 403.3.7 'Ducts declared to be within the ❑Complies Requirement will be met. [FR28]3 conditioned space are either 1) ❑Does Not completely within the continuousMj ❑Not Observable air barrier and within the building thermal envelope, 2) buried ❑Not Applicable ,within ceiling insulation in accordance with Section R403.3.6 and the air handler is located completely within the continuous air barrier and within � the building thermal envelope and the duct leakage is <= 1.5 cfm/100 square feet of conditioned floor area served by ;the duct system, or 3)the ceiling 'insulation R-value installed against and above the insulated duct>=to the proposed ceiling 'insulation R-value, less the R- value of the insulation on the 403.4 HVAC piping conveying fluids R- R- El plies Requirement will be met. [FR17]2 above 105 9F or chilled fluids ❑Does Not below 55 9F are insulated to >_R-3. ❑Not Observable j❑Not Applicable »......m � _. �,, ,,..,,�.._ _ m n.. .. � ........... .� 403.4.1 Protection of insulation on HVAC ❑Complies QRequirement will be met. [FR24]1 j piping. ❑Does Not ❑Not Observable ❑Not Applicable r 3.5.3 Hot water pipes are insulated to R R F❑Complies Requirement will be met. [FR18]2 >_R-3. j❑Does Not ash ;❑Not Observable ; j❑Not Applicable I403.6 Automatic or gravity dampers are ❑Complies Requirement will be met. i(FR19]2 installed on all outdoor air ❑Does Not intakes and exhausts. ❑Not Observable ; ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) m 3 Low Impact(Tier 3) Project Title: Naglieri Residence Report date: 07/16/24 Data filename: Page 6 of10 Section' Plans Verified I Field Verified Insulation Inspection Complies? CornmentslAssumptions ReCti value Value 303.1 All installed insulation is labeled ;❑Complies Requirement will be met. [IN1312 or the installed R-values ❑Does Not provided. ❑Not Observable ...... _ _... .�-�_ .,..o. []Not Applicable 402.1.1, Floor insulation R-value. R- R- ❑Complies See the Envelope Assemblies 402.2.6 ❑ Wood ❑ Wood ;❑Does Not ;table for values. [IN1)1 ❑ Steel ❑ Steel ❑Not Observable i jONot Applicable ..,_ .. . ...... �, . -................� 303.2, Floor Insulation installed er ❑Complies Requirement will be met. 402.2.8 !manufacturer's instructions and '❑Does Not [IN2]1 ;In substantial contact with the ❑Not Observable 6 underside of the subfloor, or floor 4ramning cavity insulation is in ;❑Not Applicable ! }contact with the top side of sheathing,or continuous insulation is installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. 402.1.1, Wall insulation R-value.If this is a, R- _ R- fOComplies See the Envelope Assemblies 402.2.5, mass wall with at least 11h of the ❑ Wood ElWood ❑Does Not !table for values. 402.2.6 wall insulation on the wall ❑ Mass ❑ Mass ❑Not Observable IIN311 exterior,the exterior insulation requirement applies(FR10). ❑ Steel ❑ Steel ❑Not Applicable [IN4) p w.. ._. .... o,W ..., �.,. � 303.2 Wall nnunsulati is installed nst ll instructions. ❑D mplies Requirement will be met. es Not Not Observable ❑Not Applicable Additional Comments/Assumptions: p m Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Naglieri Residence Report date: 07/16/24 Data filename: Page 7 of10 Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID _ _ _ _ 402.1.1, Ceiling insulation R-value. D Wood ❑ Wood ❑DoespNot table for values. Assemblies �402.2.2, ❑ Steel ;❑ Steel ;❑Not Observable 402.2.E ❑Not Applicable [Fill' _ W�m.... ,..u.. ..........._...... _ 303.1.1.1,i Ceiling insulation installed per ❑Complies Requirement will be met. 303.2 manufacturer's instructions. ❑Does Not [FI2]1 Blown insulation marked every °E]Not Observable 300 ft2. ❑Not Applicable 402. a ........_ _._. .......� 2.3 Vented attics with air permeable ;❑Complies r Requirement will be met. [FI22]2 insulation include baffle adjacent ❑Does Not to soffit and eave vents that ❑Not Observable extends over insulation. ❑Not Applicable 402.2 4 Attica access hatch value and do r R- R_ ❑❑Do spNot Requirement ement will be met. [F13]1 adjacent assembly. ❑Not Observable I ❑Not Applicable 402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50 = ❑Complies Requirement will be met. [F117]1 ach in Climate Zones 1-2, and ❑Does Not <=3 ach in Climate Zones 3-8. I[�JJNot Observable If Not Applicable [F 3.3 determine air leakage with _ft2 ft2 ❑Dom lies ,:Exception: tined space. All ductsand air 403.3 3 Ducts are pressure tested to cfm/100 cFm/100 ❑C p p 1 1 Z z oes Not d within :either: Rough-in test:Total ❑Not Observable ;co ileakage measured with a ;pressure differential of 0.1 inch ❑Not Applicable j w.g. across the system including ;the manufacturer's air handler enclosure if installed at time of test. Postconstruction test:Total leakage measured with a pressure differential of 0.1 inch w.g.across the entire system including the manufacturer's air handler enclosure. .... ........... _ ......- .......�.. 403.3.4 Duct tightness test result of<=4 cfm/100 cfm/100 ElComplies Exception: All ducts and air [FI4]1 cfm/100 ft2 across the system or ft2 ft2 j❑Does Not handlers are located within <=3 cfm/100 ft2 without air conditioned space. handler @ 25 Pa. For rough-in ;L.......GNot Observable tests,verification may need to C....VNot Applicable occur during Framing Inspection. 403.3.2.1 'Air handier leakage designated ❑Complies Requirement will be met.. [F124]1 by manufacturer at<=2%of `❑Does Not .design airflow. 'E]Not Observable :❑Not thermostats Programmable Applicable 03 4 .1.1 Pro th �❑ _ _..._�.....M. .. g Complies Requirement will be met. [Flg]2 installed for control of primary ;❑Does Not heating and cooling systems and ❑Not Observable initially set by manufacturer to ❑Not code specifications. Applicable �.� .. Requirement 403.1.2 Heat pump thermostat installed ❑Com plies q ement will be met. [FI10]2 on heat pumps. ;❑Does Not ❑Not Observable ❑Not Applicable ....... 403.5.1 Circulating service hot water ❑Complies Requirement will be met. �[Flll]� systems have automatic or '[]Does Not accessible manual controls. ❑Not Observable ❑Not Applicable j mpact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) 1 High I �.m... � .. Project Title: Naglieri Residence Report date: 07/16/24 of10 Data filename: Page Section Plans Verified Field Verified - # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID _ FI25]2 fans not art of tested system � � �.®Complies �Requirement will be 403.6.1 All mechanical ventilation met. [ p ested and listed ❑Does Not HVAC equipment meet efficacy and air flow limits per Table ❑Not Observable R403.6.1, ❑Not Applicable ._...._.. ..... 403.2 Hot water boilers supplying heat " ❑Complies ;Requirement will be met. [F126]2 through one-or two-pipe heating ❑Does Not systems have outdoor setback control to lower boiler water ;❑Not Observable temperature based on outdoor ❑Not Applicable tempera�ture. TC 403.5.1.1�.�.,. Heated water circulation systems Complies Requirement will be met. [FI28]2 have a circulation pump.The ❑Does Not system return pipe is a dedicated ❑Not Observable return pipe or a cold water supply pipe. Gravity and thermos- ❑Not Applicable syphon circulation systems are not present. Controls for circulating hot water system pumps start the pump with signal ; for hot water demand within the occupancy. Controls automatically turn off the pump when water is in circulation loop is at set-point temperature and no demand for hot water exists. Re 403.5.1.2 Electric heat trace systems ` P q ❑Com lies uirement will be met. [FI29]2 comply with IEEE 515.1 or UL '❑Does Not 515. Controls automatically adjust the energy input to the :❑Not Observable heat tracing to maintain the ❑Not Applicable j desired water temperature in the piping. tea. a«403.5.2 -- Demand recirculation water ;❑Complies Requirement will be met. [F130]2 systems have controls that ❑Does Not manage operation of the pump and limit the temperature of the ❑Not Observable 'Y water entering the cold water ❑Not Applicable piping 403.5.4 Drain water heat recovery units - r .... E]Complies Requirement _ et... . . ......._� will be met„ [FI31]2 tested in accordance with CSA ❑Does Not B55.1. Potable water-side pressure loss of drain water heat ❑Not Observable recovery units < 3 psi for ❑Not Applicable individual units connected to one or two showers. Potable water- side pressure loss of drain water heat recovery units < 2 psi for .individual units connected to three or more showers. o � ❑Com lies Requirement will be met. 404.1 ;90%or more of permanent P q [FI6]1 fixtures have high efficacy lamps.' -]Does Not ❑Not Observable 1 ❑Not Applicable _..�.. _........ .. ,..,,�.... ----.._ 404.1.1 Fuel gas lighting systems have ❑Complies Requirement will be met. I[F123]3 no continuous pilot light. ❑Does Not ❑Not Observable 4013 ❑Not Applicable Compliance certificate posted. ❑Complies ;Requirement will be met. [F17]2 ❑Does Not ,[-]Not Observable ❑Not Applicable Medium Impact(Tier 2) 3 Low Impact(Tier 3) 1 High Impact(Tier 1) 2 � ��� Project Title: Naglieri Residence Report date: 07/16/24 Data filename: Page 9 of10 section Plans Verified Field Verifled Inspection Provisions Value Value P P „ 6e R _.. ........ ;, CoP..11 Requirement will be met. 303.3 ,Manufacturer manualsfor ❑Com lies es? Comments Assum t ons� [FI18]3 mechanical and water heating ❑Does Not systems have been provided. °❑ ' Not Observable r ❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Naglieri Residence Report date: 07/16/24 Data filename: Page 10 of10