HomeMy WebLinkAbout52116-Z TOWN OF SOUTHOLD
BUILDING DEPARTMENT
TOWN CLERK'S OFFICE
SOUTHOLD, NY
BUILDING PERMIT
(THIS PERMIT MUST BE KEPT ON THE PREMISES
WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS
UNTIL FULL COMPLETION OF THE WORK AUTHORIZED)
Permit#: 52116 Date: 07/18/2025
Permission is hereby granted to:
Anthony F Naglieri
9 Rodney St
Port Jefferson Sta, NY 11766
To:
construct a single-family dwelling as applied for per SCHD approval.
Premises Located at:
1000 Fleetwood Rd, Cutchogue, NY 11935
SCTM# 137.-5-8
Pursuant to application dated 11/06/2024 and approved by the Building Inspector.
To expire on 07/18/2027.
Contractors:
Required Inspections:
Fees:
Single Family Dwelling-NEW $3,779.63
CO- RESIDENTIAL $100.00
Total 93,879.63
L
Uilding Inspector
urci;oy TOWN OF SOUTHOLD —BUILDING DEPARTMENT
Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959
• Telephone (631) 765-1802 Fax (631) 765-9502 htt s://www.southoldtowmiv.gov
Date Received
APPLICATION FOR BUILDING PERMIT
4
For Office Use Only ti
PERMIT N0,-5� Building Inspector: �° K"
ApaClctins and;ftarmahst, flled ,ia inleirltiret .ir�cnplet
p i tia r61N ra t be cept , ,;iN r th #pp lito l ndttbe a n a a
plrrip ote
Date:8-6-2024
OWNEA0 00V""'40ERTy:
Name:Anthony & Patricia Nagher TM 000-137-5-8
Project Address: 1000 Fleetwood Rd, Cutchogue NY 11935
Phone : Email:
Mailing Address:
r"
Name:Jonathan Grano
Mailing Address:850 Lincoln Ave, Suite 10 , Bohemia NY 11716
Phone :631- 41761 n Email:Jon @ jgranocontractng.com
DES,NJP PFESSNCNI��114 0 l� 011�9w
Name:
Mailing Address:
Phone : Email:
CONTRACTOR,,INFQRIVIATIO,N ,
Name:North Fork Building Company
Mailing Address:850 Lincoln Ave, Suite 10, Bohemia NY 11716
Phone :631-708 107 Emall:Jon@ northtorkhuildingcompany.com
;:;
ft
®New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project:
❑Other
Will the lot be re-graded? R'Yes ❑No Will excess fill be removed from premises? ❑Yes ®No
1
PROPERTY INFORMATION
Existing use of property: Residential Intended use of property: Residential
Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to
R-40 this property? ❑Yes ®No IF YES, PROVIDE A COPY.
�, +� `p!g,, Mr" �IrMg., "� �an�r/��►ntw��tPr�adesi � n�uf��sl�aa1 I� sgpo�i��� �rr a9); ral� ��: rid�t�"b�r��+rr I�s��s a�p�rvlsl�c��a�r
a t r ft ,T�xw n d w xl� 4ti iW i R bl t �kh pu,iCding G artrnweut° r x issu ooaa r IldloS rWtpursq�in t ull
Ck in pri .
T� �ra� �x�I�ol+ ��ai� o�ur� +"r t���rr�"�rk arrtl�th�r ap�iiwl+� s,Cir�ir���tis o� eg�ul��][rt��s���or 'o �rostnrctlo�a t�f ?�ildir� �
a i l rs; ill- wti�r�ts'nr f+r� r�%orrtul rror`d± oiit r s orei psccik ,fide appl6 nt a egis two p,y',w all 4pq iG apal lags, } � I lrr ,
housin�'crad�ar��or+��rulatians�rlst tcw,�t9w�it pukhorii�d�osp �tor�vas pr�rnwis�s arr�d tin bulldNng�s�fog"�rpc+�ss�ry i�sle�tios"ais+e:s � �rats � i� bl�alr�
punishsbl0as* ussrA iisiem ainarp4fsO 6 ItoSattl tw 10A '9fthedieYuri:StagfienaIlam:
Application Submitted By(print n e): Al 0�' El Authorized Agent i9owner
Signature of Applicant: Date:
STATE OF NEW YORK)
SS:
COUNTYOF �.? )IL )
1(�A """" being duly sworn, deposes and says that(s)he is the applicant
(Name of incllAual signing contract)above named,
(S)he is the
(Contractor,Agent, Corporate Officer,etc.)
of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this
application;that all statements contained in this application are true to the best of his/her knowledge and belief; and
that the work will be performed in the manner set forth in the application file therewith.
Sworn before me this
a day of 0C\-Q\11 e�r , 20 zu
Notary P
STATE �,,.
,'"OF NEW Y RK. �?
E PUBLIC
PROPERTY OWNER AUTHORIZATION `
(Where the applicant is not the owner)
I, residing at
do hereby authorize to apply on
my behalf to the Town of Southold Building Department for approval as described herein..
Owner's Signature Date
Print Owner's Name
2
q 7 J L
N0
14—
NAGLIERI RESIDENCE ` Tx
Fu.- ,. . .....
cI I P"'HUGL7I Nr.W YQazK
I R- RA C2 SUFFOLK ouN-Tv DEa ART EW O) HEALTH SERVICE
.:Ge t z sue_Isy:s IER b0RAPPROVAL OF CORImIGN FoR AWWM- C�v
,,_
SINGLE F MIL"RESIDENCE ONLY I
DA
$ 6/25/2024 REF_ G. R-24-0788 i
_ €
APPROV
FOR MAxtmum 0 A epees V
s EXPIRES THREE YEARS FROM DATE OFAPPRC)ttA_ O
I -
E E CAL'0."
q—
ec` w''ca.lc�l
ALL
ELECTEIr
E rmrrl TO r•. _
FORMED
N Aa�YOA EE -
"I NET
LI ''
x
I ' � - C@RAGI IN TlI�AJSW
#-FuJ IC19.n USA
,_..,,,,".h +F I sm � .. I IuiTJIYMtlNS .IAIIUtt.NYli.
t.y �x ...4 I � Wl1liH11A➢➢IU.�
I I I IUILIIUL� ➢I
Fj
I
t `-
4
u wv a M1` Y �, unV IJrun aW VVVunu
t
PROPOSED
r RESIDENCE
,.�r � I
0
LJ I= NAGLIERI
u oo IY. RESIDENCE
IOOO Fl FK'lll00ll I(uVl
Iw I'l 11'('1101 Ell. N) I I Id:.
1 ` 9 Ic.
c,
SOWN I Y}II 1uoll,
._# J12
_ ` ovAnc Yrax.
SITE MAP
e ®PROPOSED SITE PLAN
x
III> -:,YI
Flo�oA�E
ffE��
I"
..,A SAY SAY amk e
4.= -
— ICI nlr:,war
SCH D-1
Generated by REScheck-Web Software
Compliance Certificate
Project Naglieri Residence
Energy Code: 2018 IECC
Location: Cutchogue, New York
Construction Type: Single-family
Project Type: New Construction
Orientation: Bldg. faces 0 deg. from North
Conditioned Floor Area, 4,038 ft2
Glazing Area 19%
Climate Zone: 4 (5572 HDD)
Permit Date:
Permit Number:
All Electric false
Is Renewable false
Has Charger true
Has Battery: false
Has Heat Pump: true
Construction Site: Owner/Agent: Designer/Contractor:
1000 Fleetwood Road Anthony Naglieri Michael Dunn
Cutchogue, New York 11935 9 Rodney Street Michael Dunn Architect
Port Jefferson Station, New York 256 Orinoco Drive
11776 Suite B
631-335-7923 Brightwaters, New York 11718
tonynags@hotmail.com 646-448-8997
Mike.mkdarchitect@gmail.com
Compliance: 20.7%Better Than Code Maximum UA: 488 Your UA: 387 Maximum SHGC: 0.40 Your SHGC: 0.40
The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules,
It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home.
Slab-on-grade tradeoffs are no longer considered in the UA or performance compliance path in REScheck. Each slab-on-grade
assembly in the specified climate zone must meet the minimum energy code insulation R-value and depth requirements.
Envelo
e As ae Li
Gross Area Cavity Cont. Prop. Req. Prop. Req.
Assembly or
Perimeter
Flat Ceiling: Flat Ceiling or Scissor Truss 1,893 49.0 0.0 0.026 0.026 49 49
South Wall:Wood Frame, 16" D.C. 642 15.0 10.0 0.042 0.060 19 27
Orientation: Back
Door: Glass Door(over 50%glazing)
SHGC: 0.40 160 0.300 0.320 48 51
Orientation: Back
Window:Wood Frame
SHGC: 0.40 38 0.300 0.320 11 12
Orientation: Back
Project Title: Naglieri Residence Report date: 07/16/24
Data filename: Page 1 of10
x
Gross Area
Cont. 1Prop. 1
Assembly 1
1 1
Perimeter
North Wall:Wood Frame, 16"o.c. 642 15.0 10.0 0.042 0.060 20 29
Orientation: Front
Door: Glass Door(over 50%glazing)
SHGC: 0.40 40 0.300 0.320 12 13
Orientation: Front
Window:Wood Frame
SHGC: 0.40 120 0.300 0.320 36 38
Orientation: Front
East Wall:Wood Frame, 16"o.c. 300 15.0 10.0 0.042 0.060 11 16
Orientation: Left side
Door: Glass Door(over 50%glazing)
SHGC: 0.40 20 0.300 0.320 6 6
Orientation: Left side
Window:Wood Frame
SHGC: 0.40 11 0.300 0.320 3 4
Orientation: Left side
West Wall:Wood Frame, 16" o.c. 300 15.0 10.0 0.042 0.060 10 15
Orientation: Right side
Door: Glass Door(over 50%glazing)
SHGC: 0.40 20 0.300 0.320 6 6
Orientation: Right side
Window:Wood Frame
SHGC: 0.40 34 0.300 0.320 10 11
Orientation: Right side
South Wall Second Floor:Wood Frame, 16"o.c. 395 15.0 10.0 0.042 0.060 15 22
Orientation: Back
Window:Wood Frame
SHGC: 0.40 27 0.300 0.320 8 9
Orientation: Back
North Wall Second Floor:Wood Frame, 16"o.c. 395 15.0 10.0 0.042 0.060 12 18
Orientation: Front
Door: Glass Door(over 50%glazing)
SHGC: 0.40 20 0.300 0.320 6 6
Orientation: Front
Window: Wood Frame
SHGC: 0.40 81 0.300 0.320 24 26
Orientation: Front
East Wall Second Floor:Wood Frame, 16"o.c. 265 15.0 10.0 0.042 0.060 11 15
Orientation: Left side
Window: Wood Frame
SHGC: 0.40 14 0.300 0.320 4 4
Orientation: Left side
West Wall Second Floor:Wood Frame, 16"o.c. 265 15.0 10.0 0.042 0.060 10 14
Orientation: Right side
Window: Wood Frame
SHGC: 0.40 24 0.300 0.320 7 8
Orientation: Right side
Floor:All-Wood joist/Truss 1,893 38.0 0.0 0.026 0.047 49 89
Compliance Statement. The proposed building design described here is coned he building plans,specifications,and other
calculations submitted with the permit application.The proposed buildin to meet the 2018 IECC requirements in
REScheck Version : REScheck-Web and to comply with the mandatory TY6 e REScheck Inspection Checklist.
Michael Dunn 7-2-2024
Name-Title Sign ur'e Date
Project Title: Naglieri Residence Report date: 07/16/24
Data filename: Page 2 of 10
. p
,EScheck Software Version -, REScheck-Web
Inspection Checklist.
Energy Code: 2018 IECC
Requirements: 100.0% were addressed directly in the REScheck software
Text in the "Comments/Assumptions" column is provided by the user in the RE acheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed.Where compliance is itemized in a separate table, a reference to that table is provided.
Section Plans Verified Field Verified
# Pre-inspection/Plan Review Value Value Complies? Comments/Assumptions
&Reg.ID _ _........
103.1, Construction drawings _ „. . ,_, ._����� . �o . ti.��,,, ._.._....._... _ uir m�
g and �C�Complles ;Requirement will be met.
103.2 Aocumentation demonstrate -,i Does Not
[PRl]1 energy code compliance for the ❑Not Observable
building envelope.Thermal
envelope represented on hiNot Applicable
construction documents.
�wow ........... ..
103.11 Construction drawings and EComplies ;Requirement will be met.
103.2, documentation demonstrate ❑Does Not
403.7 j energy code compliance for
[PR311 lighting and mechanical systems. ❑Not Observable
�q Systems serving multiple ❑Not Applicable
dwelling units must demonstrate
compliance with the IECC
Commercial Provisions.
302.1, Heating and cooling equipment is Heating: Heati
ng: E1Complies Requirement will be met.
4033 sized per ACCA Manual S based Btu/hr Btu/hr ,❑Does Not
[PR2)2 on loads calculated per ACCA Cooling: Cooling: ❑Not Observable
Manual J or other methods Btu/hr Btu/hr
approved by the code official. !❑Not Applicable
Additional Comments/Assumptions:
�1g Impact t(Tier 2) 3 Low Impact(Tier 3)
Hi h Im act(Tier 1) 2 Medium Impact
Project Title: Naglieri Residence Report date: 07/16/24
Data filename: Page 3 of10
Section
Foundation inspection Complies? Comments/Assumptions
& Req.ID _ _
protect e g s le to ODoespNot Requirement will.be.m.... � _.� � u .. _........
� .� �A protective covering is installed
. � � et.
p exposed exterior insulation
and dextends a minimum of 6 in. below 'Vo Not Observable
jn ..VNot Applicable
....--. .�, ....._ ..._..� .._�
41 . Snow-and ice-melting system controls Z IComplies Exception: Requirement is not applicable.
'(FO1212 installed. boes Not
❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
i ligi�impact (Tier 1) 2 Medium Impact(Twer 2) 3 Low impact(Tier 3)
Project Title: Naglieri Residence Report date: 07/16/24
Data filename: Page 4 of10
Section Plans Verified Field Verified
L # Framing/ Rough-In Inspection! Value Value Complies? Comments/Assumptions
& Reg.ID _ _ _
402.1.1, averageU- r(area-weighted �-.___ . U-�` lCoespNot table for alules Envelope
m T
Glazing facto g - Assemblies
ElD
402.3.3,
402.5 []Not Observable I
[FR2]1 ❑Not Applicable
. .1.3 - .. ...�...... .ww.._ _.
U-factors of fenestration products" ❑Complies Requirement will be met.
[FR4]1 are determined in accordance ❑Does Not
with the NFRC test procedure or
taken from the default table. ❑Not Observable
❑Not Applicable j
402.4.1.1 ,Air barrier and t _-hermal barrier ❑Comiplles ;Requirement will be met.
[FR23]1 installed per manufacturer's ❑Does Not
instructions. ❑Not Observable '
❑Not Applicable E
402.4.3 ''Fenestration
labeled a s meeting site
built
s l W pw amm mmmm m VONw� �DoespNot Requirement will
be met.
AAMA/WDMA/CSA 101/I.S.2/A440 r ❑Not Observable
or has infiltration rates per NFRC
400 that do not exceed code ❑Not Applicable
limits.
w,. , ... .....
402.4.5 IC-rated recessed lighting fixtures ;❑Complies ;Requirement will be met.
[FR16]2 sealed at housing/interior finish ❑Does Not
and labeled to indicate:52.0 cfm ❑Not Observable
leakage at 75 Pa.
❑Not Applicable
1 Supply and return ducts in attics ❑Complies Exception: Ducts located
[FR12]1 insulated >= R-8 where duct is '❑Does Not °`completely inside the
>= 3 inches in diameter and >_ -]Not Observable building envelope.
;R-6 where< 3 inches.Supply and,
return ducts in other portions of ❑Not Applicable
,the building insulated >= R-6 for
,diameter>= 3 inches and R-4.2
for< 3 inches in diameter.
403.3.2 ,Ducts, air handlers and filter 7, ;❑Complies ;Requirement will be met.
[FR13]1 boxes are sealed with ❑Does Not
!joints/seams compliant with
�� , ;International Mechanical Code or ❑Not Observable
International Residential Code, as ❑Not Applicable
applicable.
_.
403.3.5 Building cavities are not used as ❑Com p ilies Requirement will be met.
[FR15]3 ducts or plenums. ❑Does Not
[]Not Observable
❑Not Applicable
!403.3.6(1, Ducts partially or completely ❑Complies Requirement will be met.
2) buried in ceiling insulation have -]Does Not
[FR26]3 an insulation R-value not less ❑Not Observable
than R-8,the sum of the ceiling
insulation R-value against and ❑Not Applicable j
above the top of the duct, and
against and below the bottom of
the duct, is >=than R-19,
excluding the R-value of the duct
insulation.
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Naglieri Residence Report date: 07/16/24
Data filename: Page 5 of10
Sec lean � Plans Verified Field Verified
# Framing/ Rough-In Inspection Value Value Complies? Comments/Assumptions
& ID
403.3.7 'Ducts declared to be within the ❑Complies Requirement will be met.
[FR28]3 conditioned space are either 1) ❑Does Not
completely within the continuousMj ❑Not Observable
air barrier and within the building
thermal envelope, 2) buried ❑Not Applicable
,within ceiling insulation in
accordance with Section
R403.3.6 and the air handler is
located completely within the
continuous air barrier and within �
the building thermal envelope
and the duct leakage is <= 1.5
cfm/100 square feet of
conditioned floor area served by
;the duct system, or 3)the ceiling
'insulation R-value installed
against and above the insulated
duct>=to the proposed ceiling
'insulation R-value, less the R-
value of the insulation on the
403.4 HVAC piping conveying fluids R- R- El plies Requirement will be met.
[FR17]2 above 105 9F or chilled fluids ❑Does Not
below 55 9F are insulated to >_R-3.
❑Not Observable
j❑Not Applicable
»......m � _. �,, ,,..,,�.._ _ m n.. .. � ........... .�
403.4.1 Protection of insulation on HVAC ❑Complies QRequirement will be met.
[FR24]1 j piping. ❑Does Not
❑Not Observable
❑Not Applicable r
3.5.3 Hot water pipes are insulated to R R F❑Complies Requirement will be met.
[FR18]2 >_R-3. j❑Does Not
ash ;❑Not Observable ;
j❑Not Applicable
I403.6 Automatic or gravity dampers are ❑Complies Requirement will be met.
i(FR19]2 installed on all outdoor air ❑Does Not
intakes and exhausts.
❑Not Observable ;
❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) m 3 Low Impact(Tier 3)
Project Title: Naglieri Residence Report date: 07/16/24
Data filename: Page 6 of10
Section' Plans Verified I Field Verified
Insulation Inspection Complies? CornmentslAssumptions
ReCti value Value
303.1 All installed insulation is labeled ;❑Complies Requirement will be met.
[IN1312 or the installed R-values ❑Does Not
provided. ❑Not Observable
...... _ _... .�-�_ .,..o.
[]Not Applicable
402.1.1, Floor insulation R-value. R- R- ❑Complies See the Envelope Assemblies
402.2.6 ❑ Wood ❑ Wood ;❑Does Not ;table for values.
[IN1)1 ❑ Steel ❑ Steel ❑Not Observable i
jONot Applicable
..,_ .. . ...... �, . -................�
303.2, Floor Insulation installed er ❑Complies Requirement will be met.
402.2.8 !manufacturer's instructions and '❑Does Not
[IN2]1 ;In substantial contact with the ❑Not Observable 6
underside of the subfloor, or floor
4ramning cavity insulation is in ;❑Not Applicable !
}contact with the top side of
sheathing,or continuous
insulation is installed on the
underside of floor framing and
extends from the bottom to the
top of all perimeter floor framing
members.
402.1.1, Wall insulation R-value.If this is a, R- _ R- fOComplies See the Envelope Assemblies
402.2.5, mass wall with at least 11h of the ❑ Wood ElWood ❑Does Not !table for values.
402.2.6 wall insulation on the wall ❑ Mass ❑ Mass ❑Not Observable
IIN311 exterior,the exterior insulation
requirement applies(FR10). ❑ Steel ❑ Steel ❑Not Applicable
[IN4) p w.. ._. .... o,W ..., �.,. �
303.2 Wall
nnunsulati is installed
nst ll instructions. ❑D mplies Requirement will be met.
es Not
Not Observable
❑Not Applicable
Additional Comments/Assumptions:
p m Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Naglieri Residence Report date: 07/16/24
Data filename: Page 7 of10
Section Plans Verified Field Verified
# Final Inspection Provisions Value Value Complies? Comments/Assumptions
& Req.ID _ _ _ _
402.1.1, Ceiling insulation R-value. D Wood ❑ Wood ❑DoespNot table for values.
Assemblies
�402.2.2, ❑ Steel ;❑ Steel ;❑Not Observable
402.2.E ❑Not Applicable
[Fill'
_ W�m.... ,..u.. ..........._......
_
303.1.1.1,i Ceiling insulation installed per ❑Complies Requirement will be met.
303.2 manufacturer's instructions. ❑Does Not
[FI2]1 Blown insulation marked every °E]Not Observable
300 ft2.
❑Not Applicable
402. a ........_ _._. .......�
2.3 Vented attics with air permeable ;❑Complies r Requirement will be met.
[FI22]2 insulation include baffle adjacent ❑Does Not
to soffit and eave vents that ❑Not Observable
extends over insulation.
❑Not Applicable
402.2 4 Attica access
hatch value and
do r R- R_ ❑❑Do spNot Requirement
ement will be met.
[F13]1
adjacent assembly.
❑Not Observable I
❑Not Applicable
402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50 = ❑Complies Requirement will be met.
[F117]1 ach in Climate Zones 1-2, and ❑Does Not
<=3 ach in Climate Zones 3-8.
I[�JJNot Observable
If Not Applicable
[F 3.3 determine air leakage with _ft2
ft2 ❑Dom lies ,:Exception:
tined space.
All ductsand air
403.3 3 Ducts are pressure tested to cfm/100 cFm/100 ❑C p p
1 1 Z z oes Not d within
:either: Rough-in test:Total ❑Not Observable ;co
ileakage measured with a
;pressure differential of 0.1 inch ❑Not Applicable j
w.g. across the system including
;the manufacturer's air handler
enclosure if installed at time of
test. Postconstruction test:Total
leakage measured with a
pressure differential of 0.1 inch
w.g.across the entire system
including the manufacturer's air
handler enclosure.
.... ...........
_ ......- .......�..
403.3.4 Duct tightness test result of<=4 cfm/100 cfm/100 ElComplies Exception: All ducts and air
[FI4]1 cfm/100 ft2 across the system or ft2 ft2 j❑Does Not handlers are located within
<=3 cfm/100 ft2 without air conditioned space.
handler @ 25 Pa. For rough-in ;L.......GNot Observable
tests,verification may need to C....VNot Applicable
occur during Framing Inspection.
403.3.2.1 'Air handier leakage designated ❑Complies Requirement will be met..
[F124]1 by manufacturer at<=2%of `❑Does Not
.design airflow.
'E]Not Observable
:❑Not thermostats Programmable Applicable
03 4 .1.1 Pro th �❑ _ _..._�.....M. ..
g Complies Requirement will be met.
[Flg]2 installed for control of primary ;❑Does Not
heating and cooling systems and ❑Not Observable
initially set by manufacturer to
❑Not code specifications. Applicable
�.� .. Requirement
403.1.2 Heat pump thermostat installed ❑Com plies q ement will be met.
[FI10]2 on heat pumps. ;❑Does Not
❑Not Observable
❑Not Applicable
.......
403.5.1 Circulating service hot water ❑Complies Requirement will be met.
�[Flll]� systems have automatic or '[]Does Not
accessible manual controls. ❑Not Observable
❑Not Applicable j
mpact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
1 High I �.m... � ..
Project Title: Naglieri Residence Report date: 07/16/24
of10
Data filename: Page
Section Plans Verified Field Verified -
# Final Inspection Provisions Value Value Complies? Comments/Assumptions
& Req.ID _
FI25]2 fans not art of tested
system � � �.®Complies �Requirement will be
403.6.1 All mechanical ventilation
met.
[ p ested and listed ❑Does Not
HVAC equipment meet efficacy
and air flow limits per Table ❑Not Observable
R403.6.1, ❑Not Applicable
._...._.. .....
403.2 Hot water boilers supplying heat " ❑Complies ;Requirement will be met.
[F126]2 through one-or two-pipe heating ❑Does Not
systems have outdoor setback
control to lower boiler water ;❑Not Observable
temperature based on outdoor ❑Not Applicable
tempera�ture.
TC
403.5.1.1�.�.,.
Heated water circulation systems Complies Requirement will be met.
[FI28]2 have a circulation pump.The ❑Does Not
system return pipe is a dedicated ❑Not Observable
return pipe or a cold water supply
pipe. Gravity and thermos- ❑Not Applicable
syphon circulation systems are
not present. Controls for
circulating hot water system
pumps start the pump with signal ;
for hot water demand within the
occupancy. Controls
automatically turn off the pump
when water is in circulation loop
is at set-point temperature and
no demand for hot water exists.
Re
403.5.1.2 Electric heat trace systems ` P q
❑Com lies uirement will be met.
[FI29]2 comply with IEEE 515.1 or UL '❑Does Not
515. Controls automatically
adjust the energy input to the :❑Not Observable
heat tracing to maintain the ❑Not Applicable j
desired water temperature in the
piping. tea. a«403.5.2 --
Demand recirculation water ;❑Complies Requirement will be met.
[F130]2 systems have controls that ❑Does Not
manage operation of the pump
and limit the temperature of the ❑Not Observable 'Y
water entering the cold water ❑Not Applicable
piping
403.5.4 Drain water heat recovery units - r .... E]Complies Requirement _ et...
. . ......._�
will be met„
[FI31]2 tested in accordance with CSA ❑Does Not
B55.1. Potable water-side
pressure loss of drain water heat ❑Not Observable
recovery units < 3 psi for ❑Not Applicable
individual units connected to one
or two showers. Potable water-
side pressure loss of drain water
heat recovery units < 2 psi for
.individual units connected to
three or more showers.
o � ❑Com lies Requirement will be met.
404.1 ;90%or more of permanent P q
[FI6]1 fixtures have high efficacy lamps.' -]Does Not
❑Not Observable 1
❑Not Applicable
_..�.. _........ .. ,..,,�.... ----.._
404.1.1 Fuel gas lighting systems have ❑Complies Requirement will be met.
I[F123]3 no continuous pilot light. ❑Does Not
❑Not Observable
4013
❑Not Applicable
Compliance certificate posted. ❑Complies ;Requirement will be met.
[F17]2 ❑Does Not
,[-]Not Observable
❑Not Applicable
Medium Impact(Tier 2) 3 Low Impact(Tier 3)
1 High Impact(Tier 1) 2 � ���
Project Title: Naglieri Residence Report date: 07/16/24
Data filename: Page 9 of10
section Plans Verified Field Verifled
Inspection Provisions Value Value P P „
6e R _.. ........ ;, CoP..11 Requirement will be met.
303.3 ,Manufacturer manualsfor ❑Com lies es? Comments Assum t ons�
[FI18]3 mechanical and water heating ❑Does Not
systems have been provided. °❑ '
Not Observable r
❑Not Applicable
Additional Comments/Assumptions:
11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Naglieri Residence Report date: 07/16/24
Data filename: Page 10 of10