Loading...
HomeMy WebLinkAbout52072-Z TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 52072 Date: 07/08/2025 Permission is hereby granted to: Michael Rodd 200 Shipyard Ln East Marion, NY 11939 To: install roof-mounted solar panels to existing single-family dwelling as applied for. Premises Located at: 200 Shipyard Ln, East Marion, NY 11939 SCTM# 35.-8-5.5 Pursuant to application dated 06/11/2025 and approved by the Building Inspector,. To expire on 07/08/2027. Contractors: Required Inspections: Fees: SOLAR PANELS $100.00 ELECTRIC -Residential $125.00 CO-RESIDENTIAL $100.00 Total S325.00 Building Inspector�� f dd syn fF01 TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone (631) 765-1802 Fax (631) 765-9502 lttt : u w. out�oldtowgq _.Soy Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only IL '5 2 � � PERMIT N0. 0 � Building Inspector. ° .J 9 Applications and forms must be filled out in their entirety.Incomplete applications will not be accepted. Where the Applicant is not the owner,an0111 Pn1d Owner's Authorization form(Page 2)shall be completed. gat Date: OWNER(S)OF PROPERTY: Name:Michael Rodd SCTM#1000-35-8-5.5 Project Address:200 Shipyard Lane, East Marion, NY 11939 Phone#:970-376-4821 1 Email:laurenmai102@yahoo.com Mailing Address:200 Shipyard Lane, East Marion, NY 11939 CONTACT PERSON: Name: Evelyn Polvere/Sunation Solar Systems Mailing Address: 171 Remington Blvd., Ronkonkoma, NY 11779 Phone#: 631-750-9454 ext 346 Email:permitting@sunation.com DESIGN PROFESSIONAL INFORMATION: Name:Michael Dunn, Graham & Associates MailingAddress: 718 Drive, Brl htw aters NY 11 256A Orinoco g , Phone#:631-665-9120 Email:glenn@grahamassociatesny.com CONTRACTOR INFORMATION: Name:Scott Maskin/Sunation Solar Systems Mailing Address: 171 Remington Blvd., Ronkonkoma, NY 11779 Phone#: 631-750-9454 Email:permitting@sunation.com DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition RAlteration ❑Repair ❑Demolition Estimated Cost of Project: ❑Other $ S53 �ya�,�� Will the lot be re-graded? Dyes *No Will excess fill be removed from premises? ❑Yes No 1 PROPERTY INFORMATION Existing use of property: Residential Intended use of property: Residential Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes BNo IF YES, PROVIDE A COPY. ❑ Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210AS of the New York State Penal Law. Application Submitted By(print name): ott Maskin I]Authorized Agent ❑Owner Signature of Applicant: Date: b 1 6 f Z6- STATE OF NEW YORK) SS: COUNTY OF Suffolk Scott Maskin being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract) above named, (S)he is the Contractor (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this day of CA 20a 7r Ncta Publi f+1r8r .Pl lic, State Of fst rat n 01VI l Ia�dualliled In Suffolk Coate PROPERTY OWNER AUTHORIZATION Ivly Commission Explr+ OOL Wr 30 i (Where the applicant is not the owner) Michael Rodd residing at 200 Shipyard Lane East Marion do hereby authorize Scott Maskin to apply on my aIf to the To4110 ui1 i g D artment for approval as de cr" d herein. Owner's Signature Date Michael Rodd Print Owner's Name 2 BUILDING DEPARTMENT-Electrical Inspector TOWN OF SOUTHOLD � . Town Hall Annex- 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 µ" ro err southoldtownn . ov seand southoldtownn r 'ov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Company Name: SUNation Solar Systems, Inc Name: Scott Maskin License No.: 33412-ME email: permittingosunation.com Address: 171 Remington Blvd, Ronkonkoma NY 11779 Phone No.: 631-750-9454 JOB SITE INFORMATION (All Information Required) Name: Michael Rodd Address: 200 Shipyard,Lane East Marion NY 11939 Cross Street: Phone No.: 970-376-4821 BIdg.Permit#: 5 0 email: . laurenmail02Cyahgo.com Tax Map District: 1000 Section: 35 Block: 8 Lot: 5.5 BRIEF DESCRIPTION OF WORK (Please Print Clearly) Installation of s n - n roof Circle All That Apply: Is job ready for inspection?: YES / NO Rough In Final Do you need a Temp Certificate?: YES / NO Issued On Temp Information: (All information required) Service Size 1 Ph 3 Ph Size: A #Meters Old Meter# New Service- Fire Reconnect- Flood Reconnect- Service Reconnected - Underground - Overhead # Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information:: PAYMENT DUE WITH APPLICATION Request for Inspection FormAs SSess6 5�47� Graham Consulting Corp. 2560rinoco Drive,Suite A Brightwaters,NY 11718 Planning& Design (631)665-9619 June 5, 2025 Town of Southold Building Department 54375 Rt. 25 Southold, NY 11971 Re: Rodd Residence 200 Shipyard Lane East Marion, NY Proposed 18.92 KW PV System To Whom It May Concern, Please be advised that I have analyzed the existing roof structure at the above-mentioned premises and have determined that it is adequate to support the additional load of the solarpanels and a 140 mph wind load and 20 psf snow load without overstress, in accordance with the following: The 2020 New York State Uniform Fire Prevention and Residential Building Code; Town of Southold Local Code, Long Island Unified Solar Permit Initiative, (LIUSPI); and 2020 National Electric Code NFPA 70/2020 National Electric Code including ASCE7-16 If you have any further questions, do not hesitate to call. z Z m ly M l Y`w nn, RA S E G = www.segsolar.com SOLAR .�y~'..'h! �.` + �r K..'tA,' v.,`�,uyK�w �.ti .M" •7 :a�:�'z;`Y Mt`.ai ...3;to„a.«µ,' 'a a, ir•e,w+r, ; .,__` , •,t. 4fs. phi. :.. ..Yy ''tr�M. y'X...,;y, �C.ia+'h :L� ,.L�'..:. �,s�' �.{.`';: p�'t •4 t�.4,d"�f�1:�.4 t:+ .i.q:, +C;t.-�.'�: ,. +i , W. 9 .s",�•, V''.t•:t!,.-s.. ;1s.,.,>+n!'it,,,`;rti�,i�'p,i.'t'S'ay '.,;�.�,n.•,:Y.". u �., N�,iKK•�.tY���:.1��.,jn,�I f zi.1�,AA".,,i�'b�.;y,•'»,>.y":&k'ry' tx' � '�.a4.i&r.3e'^'" .. .., ' bw : � r� y Key Features f t res • _ ___.�_.� . . ..... . _ High module ll Better temperature conversion efficiency O coefficient Super multi busbar @13 Low attenuation long technology warranty 77. aai Superior load < Higher bifacially Q capacity USA based liability sEG Houston,Texas + u A insurance based company .. i i Warranty Product Certification loons 990% IEC61215:2016; IEC61730:2016; UL61215; UL61730 9T4% IEC62804 PID •,v Additional Value From Linear Warranty 934% IEC61701 Salt Mist D 41 ,g4 91 4% 0 9%' so 4% IEC62716 Ammonia Resistance 99 --------- a. Dust and Sand 1 a% 87 a% I[C60068 t 9% lIC61215 Hailstone Pre Type(UL61730):Type 29 Ii014001:2015; IS09001:2015; ISO45001:2018 e to 15 po 2s ao s V� �� V CALIF RNIA Years il/,n PV CYCLE li7V ENERG✓ ENERGY COMMISSION Irtertek Guarantee on Linear power product material output O FSEC Years and workmanship Years warranty About SEG Solar ; Founded in 2016,SEG is a leading vertically integrated PV manufacturer headquartered inHouston,Texas,U.S.,and is dedicated to delivering reliable and cost-effective solar modules to the utility,commercial and residential markets.By the endof 2023,SEG has shipped over 5 GW of solar modules worldwide. Download Datasheet of 2024. The company is expected to exceed a production capacity of 5.5 GW by the end SG ' s of YUKON N Series SEG-XXX-BTD-BG-108Cells Module Type SEG-420-BTD-BG SEG-425BTD-BG SEG-430-BTD-BG SEG-435-BTD-BG Front Front Back Front Font Back Front Front Back Front Front Back STC NOCT sTC STC IOCT vc STC NOCT sTc STC NOCT STC Maximum Power-Pmp(Wp)* 420 316 336 425 320 340 430 324 344 435 328 348 Open Circuit Voltage-Voc(V) 38.50 36.58 38.48 38.70 35.77 38.68 38.90 36.96 38.88 39.10 37.19 39.08 Short Circuit Current-ISC(A) 13.83 11.06 11.06 13.91 11.13 11.13 13.99 11.19 11.19 14.07 11.26 11.26 Maximum Power Voltage-Vmp(V) 31.90 29.99 31.88 32.10 3).21 32.08 32.30 30.41 32.28 32.50 30.63 32.48 Maximum Power Current-1tri 13.17 10.54 10.54 13.24 1).59 10.60 13.32 10.66 10.66 13.39 10.71 10.71 Module Efficiency() 21.51 21.76 22.02 22.28 Power Tolerance(W) (0,+4.99) Maximum System Voltage 1500V DC Maximum Series Fuse Rating 30 A Bifaciality 80±10i STC:Irradiance 1000 W/ml module temperature 25°C AM=1.5 NOCT:Irradiance£OOW/m'ambient temperature 21 module temperature 45°C wind speed:1m/s *Measuring tolerance:±3q . ' - - External Dimension 1722 x 1134 x 30 mm Weight 24.0 kg -- - Solar Cells N-T a 182 x 91 n 1 cs) YP ( 08 P Front Glass 2.0 mm AR coating semi-tempered ghss I ' IIII I Back Glass 2.0 mm Semi-tempered glass Frame Black anodized aluminium alloy Ill hill Junction Box IP68/3 diodes I Ill illll ' J I I Connector Type MC4I inl, I! III II�II I' HER CablePV Wire(UL) III II I I IIII Iltl IIIIIIII II'III III ICI Cable Type Portrait:400 mm(+)/200 mm(-) Cable Length Landscape:1200 mm(+)/1200 mm(-) I llli I Ili1 I ICI I� or customized length Mechanical Load(Front) 5400 Pa/113 psf* U Mechanical Load Rear 4a/50 psf* Mec 200 P Load(Real IIIj *Refer to SEG installation manual for details - 1134t2 .___. _3031.1 JIM Pmax Temperature Coefficient 0.30 /"C Container 20'GP 40'HQ 40�A4 1 I I Voc Temperature Coefficient -0.25%/'C Pieces per Pallet 36 36 36 Isc Temperature Coefficient +0.046 q/°C P j Pallets per Container 6 24 22IT Operating Temperature -40-+85°C Nominal Operating Cell Temperature(NOCT) 45±2'C Pieces per Container 216 864 792 III fill I irp , 1 I J.I I hll':il'' II' IIIIIP !11�'lll� II I� � 'f J dIIIIlid, I' 18 16 ''I1 IIII y1 �, 16 Cells temp.=25°C 14 - nrrrrrm A( ! Incident brad=1000W/m' '� 14 12 ` II �1 i IIII II ! i I II Incident brad=BOOW/m' a 12 a 10 } III III IIIIIIII i�i 10 Incident brad.=600W/m' v 1 _ t0E532 8 Incident Irrad=1000W/m' a Incident Irrad.=400W/m' 6 -Cells temp.=10°C 6 -Cells temp=25°C 4 -Cells temp=40°C ' I 4 Incident brad=200W/m' -Cells temp F ...____._ .._ _._- _ ` 2 -Cells temp=70°C \\I�-/2 0 00 10 20 30 40 50 60 0 10 20 10 40 50 secibn A-A I ZI_ rdi s� Volta e[V] Voltage[V] g *Refer to SEG installation manual for details www.segsolar.com Specifica'ions subject to technical changes SEG_DS_EN_2024V3 2 0 Copyright 2024 SEG Solar ENPHASE. Q 8 M C M i c ro i nve rte r Easy to install Our newest I08 Series Microinverters are the Industry's first microgrid-forming',software- Lightweight and compact with plug- defined microinverters with split-phase power conversion capability to convert CC power to and-play connectors AC power efficiently.The brain of the semiconductor-based microinverter is our proprietary Power line communication(PLC) application-specific integrated circuit(ASIC),which enables the microinverter to operate in between components grid-tied or off-grid modes.This chip is built in advanced 55-nm technology with high-speed Faster installation with simple two-wire digital logic and has superfast response times to changing loads and grid events,alleviating cabling constraints on battery sizing for home energy systems. _ High productivity and reliability ' Produces power even when the grid is down* • More than one million cumulative hours 9 of testing Part of the Enphase Energy System, IQ8 Series Microinverters redefine Class II double-insulated enclosure IQ8 Series Microinverters integrate with reliability standards with mo,e than one Optimized for the latest high-powered the IQ Battery,IQ Gateway,and the million cumulative hours of power-on PV modules Enphase App monitoring and analysis testing,enabling an industry-leading software. limited warranty of up to 25 years. Microgrid-forming • Complies with the latest advanced grid ® support Remote automatic updates for the latest grid requirements Configurable to support a wide range Connect PV modules quickly and easily IQ8 Series Microinverters are UL Listed of grid profiles to the I08 Series Microinverters that have as PV rapid shutdown equipment and Meets CA Rule 21(UL 1741-SA)and IEEE integrated MC4 connectors. conforms with various regulations when 1547:2018(UL 1741-SB) installed according to the manufacturer's instructions. NOTE: • I08 Microinverters cannot be mixed together with previous generations of Enphase microlnverters (IQ7 Series,I06 Series,etc.)In the same system. *Meets UL 1741 only when installed with IQ System Controller 2 and 3. IQ Gateway is required to change the default grid profile at the time of installation to meet the local Authority Having Jurisdiction(AHJ)requirements. ®2023 Enphase Energy.All rights reserved.Enphase,the a and CC logos,IQ and certain other marks listed at hops://enphase.com/trademark-usage-Guidelines are trademarks of Enphase Energy,Inc.in the US and other countries. Data subject to change. IQBMC-MC4-DSH-00049-3.0-EN-US-2023-10-18 I08MC Microinverter .. >. '.: .1 Commonly used module pairings W 260-460 wModule compatibility To meet compatibility,P�modules must be within the following max.input DC voltage and max.module l,, Module compatibility can be checked at https://enphase.com/installers/microinverters/calculator. MPPT voltage range V 25-45 Operating range v 18-58 Min./Max.start voltage V 22/58 Max.input DC voltage v 60 Max.continuous operating DC current A 14 Max.input DC short-circuit current A 25 Max.module I. A 20 Overvoltage class DC port II DC port backfeed current mA 0 PV array configuration Ungrounded array;no additiona'DC side protection required;AC side protection requires max 20 A per branch circuit Peak output power VA 330 315 Max.continuous output power VA 320 310 Nominal grid voltage(L-L) v 240,split-phase(L-L),180° 208,single-phase(L-L),120° Min./Max.grid voltage P v 211-264 183-229 Max.continuous output current A 1.33 149 Nominal frequency Hz 60 Extended frequency range Hz 47-68 AC short circuit fault current over three cycles A,_ 2.70 Max.units per 20 A(L-L)branch circuit 3 12 10 Total harmonic distortion % <5 Overvoltage class AC port III AC port backfeed current mA 18 Power factor setting 10 Grid-tied power factor(adjustable) 0.85 leading...0.85 lagging Peak efficiency % 97.4 97.2 CEC weighted efficiency % 97.0 96.5 Nighttime power consumption mW 33 25 0 C to 65°C(-40°F to 149°F Ambient temperature range _ ) Relative humidity range 4%to 100%(condensing) DC connector type Staubli MC4 Dimensions(H x W x D);Weight 212 mm(8.3")x 175 mm(6.9")x 30.2 mm 0.2");1.1 kg(2.43 ibs) Cooling Natural convection-no fans Approved for wet locations;Pollution degree Yes;PD3 Enclosure Class II dable-insulated,corrosion-resistant polymeric enclosure Environ.category;UV exposure rating NEMA Type 6;outdoor CA Rule 21(UL 1741-SA),UL 62109-1,IEEE 1547:2018(UL 1741 SB),FCC Part 15 Class B,ICES-0003 Class B,CAN/CSA-C22 2 NO.1071 01 Certifications This product is UL Listed as PV rapid shutdown equipment and conforms with NEC 2014,NEC 2017,NEC 2020,and NEC 2023 section 690.12 and C22.1-2018 Rule 64-218 rapid shutdown of PV systems for AC and DC conductors when installed according to the manufacturer's instructions. 11)No enforced DC/AC ratio. (2)Nominal voltage range can be extended beyond nominal if required by the utility. (3)Limits may vary.Refer to local requirements to define the number of microinverters per branch in your ana. I08MC-MC4-DSH-00049-3.0-EN-US-2023-10-18 SnapNrackll Ultra Rail Roof Mount System . :,. �.. , {� � r � � _, , .c �1Pr. 'n+-m•+o-w..rvm+xaerap�r..,...x.... h- •'w.osa. � � .- - ., 'ua,.ca¢wr.-.t'2i1^.'TS'8..�^C.,yy The Ultimate Value in Rooftop Solar Ax • • . • . m j, Y ' • ®. ' �' • • i • i'I ..•qMII • • • i • � • i • vY" 014N • • • • • i - • - � - i qY' � - - - •. • •t •' • • IfA • • • • • • • • y NEW! UltraFoot Roof Attachments • Features SpeedSealT"'+ Technology, a pre-installed butyl pad for easy peel & stick installation 3 / • The only single lag roof attachment with butyl sealing available • UltraFoot available in (3) configurations to accomodate rafter & deck mounting based on DeckAnchorT"' or good screw install preferences • All Ultra Foot designs feature new Flip Clamp Mount that 1' centers load over fastener & creates an easier snap-in experience with UR-45 Rail = T` A The Entire System is a Snap to Install `�;,•.::"' -r•..%�,;.'� •"^�»= ^` .. _ per;`':-_.. ... Ultra RailMounts include snap-in brackets for - -� attaching rail `:%. " LL -~ • Ultra Rail Mid Clamps & End Clamps are one-size- fits-all universal clamping height • Universal End Clamps & snap-in End Caps provide a clean look to the array edge Unparalleled Wire Management • Open rail channel provides room for running wires resulting in a long-lasting quality install • Module clamps eliminate bolt interference in the rail channel creating more space for wire management -^ • Industry best wire management offering includes . � Junction Boxes, Universal Wire Clamps, MLPE x Attachment Kits & Conduit Clamps • System is fully bonded & listed to UL 2703 " = Standard = �- 4y y4 y .a ev o-' t� a gyp 3. `4rs M iat!'w • DESCRIPTION: DOC NUMBER: SNAPNRACK, TDS, UR-45 RAIL SNR-DC-01420 DRAWN BY: PART NUMBER(S): H.WULFEKOETTER SUNRUN INSTALLATION SERVICES INC. 232-10095, 232-10096, 232-10097, 232-10098, REV: DATE: 225 BUSH STREET,SUITE 1400.SAN FRANCISCO,CA 94104 USA PHONE(877)732-2860.CONTACTQSNAPN RACK COM ME IRFORMIITION INTISDRAWINGISCONFIMNTIALIINDPRCPRIETI Y ANY UNITS: IN, LB, DEG [MM, KG, DEG] SHEET: 1:1 3/6/2024 REPROWCDON,DISITTEN EENTOR FSUNRUNS THEREOF SOUTH ITEDWRHWTTHE WRITTENCONSENTOFSUNRUN SODTM 81 UR-45 RAIL PROPERTIES SKU FINISH RAIL LENGTH WEIGHT (lb) 232-10095 MILL 172 in 5.55 232-10096 BLACK 172 in 5.55 232-10097 MILL 94 in 3.03 232-10098 BLACK 94 in 3.03 .740 .895 SECTION PROPERTIES A 0.319 in Ixx 0.134 in .855 Iyy 0.121 in Sx (TOP) 0.152 in Sx (BOT) 0.156 in Sy (LEFT) 0.164 in Sy (RIGHT) 0.164 in3 MATERIALS: 6005-T5 ALUMINUM DESIGN LOAD (LBS): N/A ULTIMATE LOAD (LBS): N/A TORQUE SPECIFICATION: N/A FT-LBS CERTIFICATION: UL 2703, FILE E359313 WEIGHT (LBS): 5.48 - 5.62 (172 in), 2.96- 3.10 (94 in) 0 UlKnYMETFRPROPOSED RESIDENTIAL PLAN KEY U-8fRY10EBISCI5CD:rIFCT P" COVER SHEET ['-SLI PLY SIDECO1r1ECT1ON (16)PROPOSES ___ — PV MODULES PHOTOVOLTAIC SYSTEM Al-1 PARTIAL ROOF PLAN -AUTOMATICIRWISFERSPmCR A1-4 ROOF ACCESS PLAN t -wsA'ETER S1 1 STRUCTURE �+ MAINS RVICE PAIFI ROOF ^ o EI\11\z� AccEssSUNATION SOLAR SYSTEMS NYSERDA Et1 ONE-LINE DIAGRAM / \ 4355 � I IYERTER 171 REMINGTON BOULEVARD INSTALLER /1" 1 E2 1 PV LABELS (s-ENPNASE OCOM9l'IEA RONKONKOMA,NEW YORK 11779 NUMBER G1-1 PV PHOTOS T.PAfFLPNOTOVCtTAC n e EIECTRICVEli1ClECRAR6FA V\I/ \ Rodd Residence -EN CTTTIC IC ,s -VENTILATION - 200 Shipyard Lane, East Marion, NY 11939 ff (17)PROPOSED F-SfRSPCC11SU'"TIONMV"OR PV MODULES 18'-VENTILATION ACCESS Drawn By:Taylor MacCalium-06/05/2025 ([.,'-AC D1SCO'fNECT O ROOF /�f�/'�[� PSMCO5FJID4S1O'I'FCT �!-D A\Cj7l)+ -TESTA OATEY/AY ACCESS C ROOF -TFSLAPO.YFRYdII ri,-ENPfIASE 10 SYSTEM CONTROLLER V •♦- tg'-ENPRAgE iOSP BAKERY AOCISS HOOF HOOF "d f F:,-6ENEMT%XI PAl.EL �T Iji'tA� } It -BACKED LPEOADSCENTER O O MYeJA �1 0-VFJTT"PE . Q Q A'Y.O'Zt)R 1O J J PCOOFS "1 -f' 1 •• -EXTERIOR lOCATp`i W LU V '1 Z � N •--7ST FLOOR LOCAT104 W W U , -BASE MLfIF�OCATIIXI ACCESS ROOF aARALacAT>ov 6'•VENTiLATION Building Review Note ACCESS - •19'•VENTILATION nooF -1e'-VENTILATION < Town building examiner has received the enclosed document for minimum acceptable plan submittal requirements of the town as specified in the building and/or Residential -18'-VENTILATION _18. Code of the State of New York. This review does not guarantee compliance with that Accfss 1s' FRONT OF HOUSE code. that responsibility is guaranteed under the seal and signature of the New York State licensed design professional of record. That seal and signature has been PROPOSED PV SYSTEM A ROOF FACING STREET OR DRIVEWAY interpreted as an attestation that,to the best of the licensee's belief and information Module Type/Qty: (44)SEG-430-BTD-BG ❑ O the work in this document is: • Accurate • Conforms with governing codes applicable at the time of submission Module Dimension: 67.8"x 44.65"x 1.18" (,)PROPosen • Conforms with reasonable standards of practice and with view to the PV MODULES15�1 safeguarding of life,health,property and public welfare is the responsibility of the Module Weight/PSF: 52.91 Ibs/2.51712654614653 PSF licensee. Micro Inverter: (44)Enphase 108MC-72-M-US �(,e)PROPOSED PV MODULES __--_ Structural Statement vl�vi System DC Rating: 18.92 kW • The existing structure is adequate to support the new loads imposed by the System AC Rating: 14.0448 kW/AC O photovoltaic module system including uplift and shear. The existing rafter sizes V (a) IO and dimensions conform to RC•NYS 2020 table R802.4.1(2)-Rafter Spans. Aurora Estimated AC Production: 15,380 kWh/yr v GMSP\U (EXT) PV Notes s 1. This PV system has been designed to meet all current and applicable fire prevention setback pathways per 2020 NYS Residential Code. Proper ground clearance,roof access points,access pathways and ventilation systems shall be provided where necessary. An in depth description of each applicable code reference and exception for any codes is depicted on the PV-1 plate of this drawing package. 2. Roof shall have no more than a single layer of roof covering in addition to the solar equipment. 3. Installation of solar equipment shall be flush-mounted,parallel to and no more than 6-inches above the surface of the roof. 'v 4. Weight of the installed system shall not exceed more than 5-psf 5. Any plumbing vents are not to be cut or covered for solar equipment installation. Any relocation or modification of the vent requires a plumbing permit and Inspection. FULL HOUSE ROOF PLAN SCALE:N.T.S. This PV system has been designed to meet the minimum design standard for building and other structures of the ASCE 7-16 and the 2020 New York State Residential Code. P14 COVER PAGE JOB# 25220 REVISION # N/A SUNAT10"N REVISED BY N/A En RCS` EL <,00 C-) �A fGOOF AREA GUTTER /CIRCUT4A 0 77\ << -AR CIRCUIT 3 X1 �RIDG7E GUTTER HOOF 4 RIDGE SUNATION� SU Nation Solar Systems 171 Remington Blvd. ROOF 3 Ronkonkoma,New York 11779 (631)-750-9454 GUT-MR ­7 —RIDGE NYSFRDA INSTALLER N 4355 R F2 UMBER OOF4 JOB NUMBER RIDGE r7 25220 CIRCUIT —PIOOE CARP,rry,.) GUTTER Ch W) cli 0 Lr) GUTTER—x PIA Z Z -- 0 E 0 :2 -9 30 Z 0 cc t1i W -0 15 als WJ > 72 er GUTTER CUIT I Floor.i W C) Attachment Spacing: Portrait Attachment Spacing: Landscape Roof it Roof Description Modules Azimuth Tilt Pitch Interior Edge Corner Interior Edge Corner Southeast Roof 10 1430 360 9.6/12 4811 32" 161# 6411 48" 4811 2 Southeast Roof 1 1430 390 10.4/12 4811 3211 1611 64" 4811 4811 3 BOH Southwest Roof 17 2330 360 9.6112 4811 3211 1611 64" 4811 4811 4 Southwest Roof 16 2330 36" 9.6112 4811 32" 16" 6411 4811 4811 PARTIAL ROOF PLAN SOLAR ENERGY SYSTEMS (NY) R324.6 Roof access and pathways. Roof access, pathways and ��� setback requirements shall be provided in accordance with Sections R324.61 through R324.6.2.1. Access and minimum spacing shall be (16)PROPOSED % required to provide emergency access to the roof,to provide pathways PV MODULES 'f� +SY t to specific areas of the roof,provide for smoke ventilation opportunity areas and to provide emergency egress from the roof. Exceptions: /� �q r `✓ ,`�• �� 0 OF 1. Detached, non-habitable structures, including but not limited to detached garages, parking shade structures, carports, solar . trellises and similar structures, shall not be required to provide 18"- roof access. 18"- 2. Roof access, pathways and setbacks need to be provided where the building official has determined that rooftop operations will not be employed. _ 3. These requirements shall not apply to roofs with slopes of two -18"-VENTILATION cJUN^T,�fl� units vertical in 12 units horizontal(1 7-percentslope)or less (17)PROPOSED E i } PV MODULES 18"-VENTILATION [NY] R324.6.1 Pathways. Not fever than two pathways, on separate ACCESS S 171 R n Solar Systems roof planes from lowest roof edge to ridge and not less than 36 inches ROOF 171 Remington Blvd. Ronkonkoma,New York 11779 (914 mm)wide,shall be provided on all buildings. Not fewer than one O (631)-750.9454 pathway shall be provided on the street or driveway side of the roof. For each roof plane with a photovoltaic array,a pathway not less than ACCESS NYSEROA A3 5 36 inches(914 mm)wide shall be provided from the lowest roof edge ROOF INSTALLER to the ridge on the same roof plane as the photovoltaic array, on an NUMBER adjacent roof plane, or straddling the same and adjacent roof planes. Pathways shall be over areas capable of supporting file fighters JOB NUMBER accessing the roof. Pathways shall be located in areas with minimal aROFss ROOF 25220 obstructions such as vent pipes, conduit, or mechanical equipment. Pathways on opposing roof slopes shall not be located along the same < < plane as the truss, rafter, or other such framing system that supports O O the pathway. g a ACCESS Exception: V < ~ I— ROOF 1. Access pathways shall not be required on roof slopes containing rn � , � N photovoltaic modules, panels, or an array where the opposing ACCESS _ m o ROOF N or adjacent roof slope is an access roof. -18"-VENTILATION Z o ACCESS Z Z �p -18"-VENTILATION ROOF 0 Access Roof-A roof surface that: .18"-VENTILATION Q " E 1. Can be accessed from the ground by the fire service. -18"-VENTILATION cc -18"- O �w m 2. Is capable of providing fire service access to the ridge or peak of an opposing or adjacent roof surface that contains < ACCESS "18 - FRONT OF HOUSE Z a photovoltaic modules,panels,or an array. V Access aooF `° 3. Is relatively free of vents,skylights,conduits,mechanical ROOF FACING STREET OR DRIVEWAY O T equipment and other such obstructions. � 4. Does not contain photovoltaic modules,panels or an array,or is n a single ridge roof where the maximum edge to edge width of CD CD � 3 the photovoltaic panel system does not exceed 33 percent of (1)PROPOSED the ridge length. PV MODULES [NY] R324.6.2 - Setback at ridge. Photovoltaic arrays shall not be 00)PROPOSED PV MODULES located less than 18 inches(457 mm)from a horizontal ridge. V VV [NY] R324.6.2.2 - Emergency escape and rescue opening. Panels and modules installed on dwellings shall not be placed on the portion O the roof that is below and emergency escape and rescue opening. A �Q V7V A pathway not less than 36 inches(914 mm)wide shall be provided to \V/ \v/ (B) the emergency escape and rescue opening. _1 G MSP o(EXT) AC N.T.S. DSC ROOF ACCESS PLAN A/ Typical Attachment Method SNAP'N'RACK ULTRA RA ), RIDGE 4, -079- o 0 Ni F NI PHOTOVOLTAIC 21'-8.5" MODULE SNAP'N'RACK SPEEDSEAL L-FOOT 3/4"MODULE SPACING BETWEEN ROWS AND INSTALLERS TO APPLY SEALANT ON COLUMNS(TYP.) BOTTOM SEALANT RING USE-N PC Solar Seal#900 (1)LAYER COMPOSITE SUNATION, SHINGLE r: - , f N, I SUNation Solar Systems (1)5116-X 5-0 171 Remington Blvd. RAIL SEALING LAG SCREW Ronkonkoma,New York 11779 FASTENED TO RAFTER (631)-750-9454 0 W ER RAFTER NYSER INSTALLERDA 2" x 10" 16" O.C. AOIR NUMBER %051 PLYWOOD DECKING JOB "UMBER (TYP-) WOOD FRAMING ( I', -) 25220 TYP SOFFIT ATTACHMENT TYPE APPLIED TO-ROOF'TYP' EXTERIOR WALL —11111 151-10.5" 0) LO CY) C\j 0) ROOF SECTION (TYP.) ROOF 111-411 SCALE: N.T.S. Z !R (0 0 Z 0 1 SOLAR MODULE FRAME 0 E NOTE: SPACtNG — BETWEEN MODULE ROWS AND COLUMNS. Layers -0 ti W Roof# Rafter Size/Spacing Max Span Material Sheathing — 0 0 Co Composite Plywood END CLAMP 0 (D 1-10.511 ite Shingles W M 15 cryp.) LL 11 2"X 10" 16"O.C.0.C. 4.5r Z HEIGHT ADJUSTABLE -0 2 x 10" 16"O.C. Composite Shingles I Plywood L-FOOT"P.) W -0 2 5!-311 U 1= 0 Ca 0 3 2"x 10"/16"O.C. 151-8.51, Composite Shingles 1 Plywood cn -- SNAP ICRACK Composite Shingles Plywood 0 G 0 ULTRA RAIL co 4 2 x 10"/16"O.C. 15'-8.5" >- >� (TYP-) CL .5- C HEIGHT OFF OF ROOF SURFACE C:) C) C\I 0 SOLATRIM'ST,550'PEST AND Typical Module DEBRIS BARRTFI-CUTAWAY Side Profile FORCIARFI`Y. CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA - TABLE R301.2(1) WIND DESIGN SUBJECT TO DAMAGE WINTER DESIGN ICE BARRIER MEAN ANNUAL SEISMIC DESIGN UNDERLAYMENT FLOOD HAZARD AIR FREEZING INDEX GROUND SNOW TOPOGRAPHIC WIND BORNE DEBRIS CATEGORY TEMPERATURE TEMPERATURE LOAD SPEED(MPH.) EFFECTS SPECIAL WIND ZONE ZONE WEATHERING FROST LINE DEPTH TERMITE REQUIRED 20 PSF 140 0 YES 2 B SEVERE 31-0" MODERATE TO 15 DEG NIA SEE PLANS 599 51 HEAVY EXAMINER STRUCTURE L h i, UTILITY SERVICE yT( �• _ �r Existin PSEQ Utalty Transformer Enphase A/C Branch Circuit(typ.) 120/240V • Existing Enphase Microinverter(typ.) _ PSEG Uglily M004 �+' !►�t/�T w, -^' Meter8-083B5072 1 �7V1� ATION COMBINER 12N240V \f F..y j•,;nrgi, Module J-Box(typ.) PANEL SUPPLY SIDE CONNECTION SUNation Solar Systems 171 Remington Blvd. n Ronkonkoma,New York 11779 • (r � (631)-750.9454 PV Module(typ.) ` NYSERDA 4 3 5 5 EGC Attached To Rai!(typ.) /P 200A 1 INSTALLER MAIN J NUMBER ENPHASEGATEWAY �- _ JOB NUMBERI (ko bM;mon'brug 2P2OA 2P15A 25220 11 Circuit Al tov..,0—i i CONDUIT AND CONDUCTOR SCHEDULE ENPHASE BRANCH CIRCUI7ffi1 2P20A 80A 1 —� Circuit i2 MAIN J TAG CONDUCTOR CONDUIT RUN ENPHASE BRANCH CIRCUIT it2 _J 1_ 2P20A ENPHASE BRANCH CIRCUIT F3 Circuit Y3 TYPE GAUGE QUANTITY TYPE SIZE LENGTH ENPHASE BRANCH CIRCUIT ap4 2P20A Combs 2on5A 1 Enphase Q-Cable 12 8 N/A N/A 15' �; 4, circw!r4 ,, r0 Combiner Monitor HOME MONITOR EGC G G ab,f4"Onb+00�y G 2 Type NM 10 8 NIA N/A 30' 1. I MAIN ('7 y/ �2� t3' ENPHASE �p 3 THWN-2 10 8 PVC SCH.80 1.25" 15' NC SERVICE Cn ROOF ATTIC EXTERIOR 10 COMBINER tJ DISCONNECT PANEL r N EGC 10 1 PVC SCH.80 1.25" 15' 1 Lit SERVICE RATED } O 4 THWN-2 4 3 PVC SCH.80 1.25" 10, t4? ENCLOSURE IS ,6 Z EGC 8 1 PVC SCH.80 1.25" 10' RATED_SOA MAIN-22k AIC � r 5 THWN-2 4 3 PVC SCH.80 1.25" 10' _ Z O O E N EXTERIOR V _ DISCONNECTING AI�ANS BUILDING P 6 GEC 8 1 N/A N/A 10' — _ GROUNDING Q N ELECTRODE n -2 IJ ILL O � W N qt , qt . Maximum AC Operating Current W o o Circuit# PV Module Y Micro-inverter y p 9 Enphase IQ8MC-72-M-US J 1 SEG-430-BTD-BG 10 P 10 13.3 A '2 E- 2 SEG-430 BTD-BG 12 Enphase IQ8MC-72-M-US 12 15.96 A IML m 3 SEG-430-BTD-BG 12 Enphase IQ8MC-72-M-US 12 15.96 A U) 4 SEG-430-BTD-BG 10 Enphase IQ8MC-72-M-US 10 13.3 A N p` Maximum AC Operating Current(Total)_ _ 58_52 A _ [2. 1 =I A ONE-LINE DIAGRAM D Ar )77 1=17,95747 LABEL LOCATION: LABEL LOCATION: SOURCE CIRCUITS: 1 AT EACH AC DISCONNECT,COMPLETE VOLTAGE AND MAIN DISCONNECT PANEL: 1 AT EACH AND AT BUILDING MAIN SERVICE CURRENT VALUES ON DISCONNECT LABEL. DISCONNECT IF APPLICABLE. Z NEC 2017 705.10 NEC 2017 690.54 NEC 2017 690.13(8) r it Ila WARNING ftasw ELECTRIC SHOCK HAZARD NOTE:ATTENTION STICKER GETS PLACED ON UTILITY METER IN ADDITION TO DO NOT TOUCH TERMINALS THE BUILDING MAIN SERVICE DISCONNECT. IM191 " TERMINALS ON BOTH THE LINE AND This building is equipped with an LOAD SIDES MAY BE ENERGIZED i Interconnected Electric Power SUNATION IN THE OPEN POSITION Production Source PHOTOVOCIAICil(o�SKIM�JCEDG VOLTAGE V"-NCVrR'D CYARE EXPOED TO SMIGHT SUNation Solar,Systems Source Type: 171 Remington Blvd. oma,New Solar Photovoltaic Ronkon(k631)-750-9454York 11779 jisconnect Is Located: Interior. LABEL LOCATION: Sasenent: Garage: Exterfor.— NYSER DA Ar Front: Rear. LH Side:— INSTALLER AIR 5 1 AT DER Disconnect Switch Isolator Rl Side: PSEG SGIP Chapter 7-7.2 DER Isolation Switch Isolation — Ot.�er Localion: NUMBEn 0 %AV V 5UNation Solar Systems SOLAR SYSTEM EQUIPPED JOB NUMBER 631-750-9454 www.sunation.com WITH RAPID SHUTDOWN J TURN PASD SHUTDOWN 25220 SVVTTCH TO THE 'OFP'POSMONTO armn SHUTDOWN!"VSYSTEM AND REDUCE THE SHOCKWARD 1#*Ljf� -01A F,r' '04 IN ARRAY 11 to CY) C\I 0 C\I LO Z 0 z 0 0 0 (D c- Cz Cz 0 U. Cc W UJI �0 0 0 Cc co U) 0 Ca O C\I es=� PV LABELS yl INt_'•aJ� �11 ii a:.t �� _ S j;r livA• KI 'G•� !�'•r'• ,tr'1 ;s ^*'�' rr,.$�•3+ �� �-$r / �:A'� .t� rGls r +7• rt• .1 °t�. Y. r'>.[y1 :r!e: ! ♦�.�'4^ca''""-*,h. S_ +.4- �'}l:T.�l a,� ST�.`' �.• V fit• :t:• tM,/ l> •j�(:'. ' �Y� i '1, �'��_�.5����i%-..♦ =FJ ..t , t Y a, .z&,", ..�. r Yi t; :f( :� .. - ry'}e'!. - a�';j:y".I'l l(({;� :1 .�..:*.<Yy F:'„ `?+�Y.i::�! C ,•.,;,�,• .`; 'A.6Y'rig,'7.�. � x'',"�-.<}�"`^�'a='y��,'(,r'• '1 �" 71, F 4, a' Cr ✓` qh �1 i 1 � '�"`""�L4` i.4. R,9'�'�•{I�1 ij��r ">�' .='��•���Cam`{:.ti:�:.'•}j 1 t•`t� g �! yl. .p 1,'�j� '�.' ,8 r• ,,N a!� 7� �l 1 ;1't• �`a'.rar.;r, N„ � ` { 1 tf':!:. " �.j:`'ST:»':. ,.�f•^ i:y .' r i. i y 4;. 7.s `:: } r tlr .tl � � ,�. {.;, ,,� 1 t•�,r�!'t :'7:•"R :. ,,s�..r_,,. ,*'w ,+ 1 .r-.. ,i :� .r#tl:p, s_,s, .x, / _ A+...,;, •1 '. t. ,rtt 4 i 'w.. �.' :Ya,.•-.��r 'a1.1,„a�,+ a -; >Y •/r ' i.'1`1'%•.,`•.,C t4>'. `+- Or r4c.�•'� ?v4 1.fiMT ;'i; +« 't. .li. v.#y'.,av ^-Y. fi- -_ +,,.« _,c,„- i>."l�tl .1 r _.•••,r: £'+•'�`^� �i:. �a-.• 7r e :� T s. '� + ,f.t� J« -•n�a�: �,•.- r.t 4.'•, }•�.�, ;mr' ,4,.•c•, iti~ r� .,t. �"r.a [+��}( r• .r <.• ,+,�'.Y: :irf .p :S.•^ _ _ - ,:�:�'4 ..,•,7j� r:.i+l>•r t. t J♦ram. �a i_.''!"1 ♦'.^iti R�":••' ';Z• ,t'..f�§� C 7 �. i Y H ` .. I �'�♦��tt t� .`L :'l is Y fFi.,:�:. f _ .r'iy it:•>:-". Nr.4.Y't'rF ��tieA _ 1 .J♦';'�.'•':• T.�3�, is♦',�w;,•�,.+r�� r •J.,. ria •. .ti.-.a:,w� {` f z.- ° II} •1 r:n:: '��q^,. r, Ft• ", f. Ir i%�r♦ `.-/, •Ii•'• .1 •16{•. � P 7:S}f.\.. \hr 14 -�'+_"•S'� `.:�lta`i:z...�r,;.�:t�.:�t. +^-?"�_.�itf'.'.J�S'.,1�rc�,.- x`�"•.�i_�:tii.�..c`, 2 ~."ti,, ..i'' /p 'r;-X:" �'* #• ...e '. '�S Yam. (r,,... •R. �. ,rY t• '- . 5 `\., - gyp• ,m ,SFr+.`• �" :,n�- 16^ •Zip.•,. �• �`. #�k. a'.Y: .:,'ry-," ,,_C i'•f ev. A7 � �-t; `v� ?=?:>:;• ?` a r1 r,: SUNation Solar Systems �tlj "''��: ':; :•,a i r t .;' ; k ., nr + '::y � 171 Flemington Blvd. t1{- r°`.,;s.�.. v ,1r5...�+� 0► .' �• :'/, ' 1t j f._ s•Y^ 4°l 'fr .e:::� � .+ �w .jam•• ♦b e.� •,A •t r) 1 •.a. Ronkonkoma,New York11779 F Si l.. �•' .. '•L" 1tY:, ;: T:,:.+1'::,t• 0 \S',t`":•f�.; 'J! 'lY ' ♦ • �'rl 1 ,,� Y• -zip" � =.i�'3�G' ;;...;�'- 'rs>.�s.::'::. �;'c.�'.; .`r.;;�:.^ � ',k',/••� ,.��'. L� °r< (631)-750.9454 I"%'- f•" I �i .1:' J ��;�• ;_�,:y7.'-.r:%:•:i:_:.::��:::;,- '.IM�- 11S,��'.. :.c 4�.�i.}j''�' ."�' Will ��'� lC"r5:"•:•1c,'�..n.. '�.';a•:S%is:ds;j:: -. :. '. s.„.•�• �,. } �: �i .th:•�.. �:` Y:•i `�:<:':?':;�•."'.. ., a, dsA,�r. ,�,• i', tid� t .C'Jr NYSFRDA - "�.a',, .i. --.-'--_� ':� � ,� - - ."�.t-•,t�l' `� yi. •,�, INSTALLER - ,, h ;,Y, •r� 1, t.F::. ';7z•;:.;"=. .. >s�:_';` yy�`: ,,,';_ p• ,��t"�. NUMBER 4355 - `°`4"a.. .�F> _;SY� T%==:.•. ::!°z•:g �- f' :r�r�+•' �a:l ;i• - •/4� �'.1i' .F�;f`' - «d.. '-}.-• ,�'a ,a! 1111 - `'{. a Ui%+ ,1,• ,t, �;•�•r k�•%.4•' w'�. s,. - �� '!�'<'..•-r S�, .SC .,is �".�' 1 i .q• Ett ��.�' ''� ..tt,r JOB NUMBER `�T.'',::<-'; i'ir,��';:e�•.��a�;;;t;:'y�.�"''ti-u �� ,.�?:c.�- �:�,t�fz'izEre.-r::y:� "{7�j' 't��.. 2522 ARRAY LOCATION(S) ARRAY LOCATION(S) SATELLITE IMAGE VIA GROUND VIA ROOF i lr7 x, r rn to O '••t .7` ', -'— t .•^.- JWa-••w>�_..�: ,1:. 'iS:ti:'•;'• 'r:::l10LO cz �''--^-- '` by � , tn''-{'''� /• `r;!'E�.� =L� � -.� „s vb: Q N � All a „ cr- 'h�£� � j�, :y�it ti '•`'.'" ��Zr� �. ,.;. '\���� •� �0 � t__y. ��.� .�I y '�/ LL c I. l� te„e�,a,, ;,.. •9 :;w�+`:,, ..d� i- r ilt tr a z a) uj cn Cc 00 ,:i+'` ,Y,, '," '�'#"�: ( .. ... _ i•:;. - Y_ `ram+ JA co ._ � &6�' .. _ •� -aSia.u.r+.�i-���..rc'4�'tttia SOUTH VIEW PROPOSED PV EQUIPMENT EXISTING UTILITY METER VIA ROOF LOCATION AND MDP PV PHOTOS