Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
52070-Z
TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 52070 Date: 07/08/2025 Permission is hereby granted to: Rocky Bluff LLC 20 E 9th St 12K New York, NY 10003 To: install roof-mounted solar panels to existing single-family dwelling as applied for. Premises Located at: 645 Rosenburg Rd, East Marion, NY 11939 SCTM#21.4-26.1 Pursuant to application dated 06/11/2025 and approved by the Building Inspector. To expire on 07/08/2027. Contractors: Required Inspections: Fees: SOLAR PANELS $100.00 ELECTRIC -Residential $125.00 CO-RESIDENTIAL $100.00 Total $325.00 Building Inspector i MTV TOWN O —,F SOUTI-JOLD - BUILDING DEPA13�ME 'T Town Hal Annex 54375 Main Road P. 0. Box 1179 Southold. NAY 11971-0959 a� Telephone (631) 765-1802 Fax (631) 765-9502 i Cate Received APPUCATION FOR BUH DING PERMIT For Office Use Only ? k jUN 1 1 2025 � Buildinglaas�ec��a�r. PERMIT 0. .. Applications and forms must be tilled out in their eent ntirety.incomplete rPart 1d r .� �k soatl applications will not he accepted. Where the Applicant is not the owner,an Owner's Authorization form(Page 2)shall be completed. i �a� Date: I � OWNER(S)OF PROPERTY— game: SCTM# 1000- 1 9 Project Address: Phone#: (0 3 y 2 - � Cw Mailing Address: (0 1 r,c 0,-s /) bLkr, C--aT ro ✓/ tJl' )L CONTACT PERSON: i G Mailing Address: -7 4�7 Phone#: (P3 J 3 9 7 d-7 0'4 1 Email; Pang 4,5 e i n I Name: 1 Mailing Address: Phone#: Email: CONTRACTOR IN C N-. I Mailing Address: 11�sb ' bq +V Cr, Phone#: 2) 1 ' 15t 2 °-) D 4 ) 0 -[ Email: ey- DESCRIPTION OF PROPOSE®CONSTRUCT)ON ❑fl 0 /their n, �-�.0 �o )&Ly- PV ,5 (� ro J $ew Structure ❑Addition ❑Alteration ❑Re air ❑Demoiitio Estimated Cos �roject: Will the lot be re-graded? ❑YesK- ,No Will excess fill be removed from premises? ❑Yes o i PROPERTY INFORMATION Existing use of property: Intended use of property zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? Eyes ❑No IF YES, PROVIDE A COPY. Check Box After Reading. The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print me): Q y-11 i ICl pi T____thorizecl Agent El Owner Signature of Applicant: 9AA Date: STATE OF NEW YORK) SS: COUNTY OF ) ,L rr et-/ / i � �-- being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Cz n 4? d. (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief,and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this day of .� [J�IiL e— Notary kic PROPERTY OWNER AUTHORIZATION (Where the applicant is not the owner) residing at ,2 v FA ' µ d ��- )12—AL 1 v M /J J . ( L do hereby authorize rr�/�,r to apply on G y «� my behalf to the Town of Southold Building Department for approval as described herel . Owner's Signature ate I l ✓1CY CO Public, S ate of N I;•J/(,(,� S%�Q/ � �totary Public,State of Newyork No.01R06314813 Print Owner's Name Oualified in Suffolk County Commission Expires,November iz.20.Z 6 2 ' f BUILDIIN v DEPARTMENT- Electrica9 Inspector TOWN OF SOUTHOLD Town Hall Annex - 54375 Main Road - PO Sox 1179 Southold; New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION I Information Required) 'Date; ,fir Company Name; V e m f.11 7�v° a 0ectriclan's Name: = r w',, License No.� Elec. email: �� ���� d �� d C�Ire ��star�em IcoJ �o � " Elec. Phone No: c q pl f Certificate of Compliance Elec. Address.: - 9J d POB SITE INFORMATION (All information Required) i Name: Address: are Cross Street: c 'po) W 3g Phone No.: Bldg.Permit#: email- �� G �4S '� ' ' Tax Map District: 1000 Section: Block- � / Lot: fJ t,� BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): �.a"a�'fir'�._3'! � 9 �.� lY� �"��." '� �� :������ �::✓) �� �' ;��;��.� ® >3 Circle All That Apply: Square Footage: 9s job ready for inspection?: YES NO Rough In El Final Do you need a Temp Certificate?: YES NO Issued On Temp Information: (All information required) Service Size 1 Ph 3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead LAdditional derground Laterals 1 2 H Frame Pole Work done on Service? Y Nl Information: PAYMENT,DBE WITH APPLICATION Page 1 of 2 SS.e. �' SaQ 7 Current 06/04/2025 RenewableS Element Energy LLC f Engineering 7470 Sound Avenue, Mattituck, NY, 11952 Subject: Structural Certification for Installation of Residential Solar Job: Rocky Bluff LLC - 645 Rosenburg Rd Project Address: 645 Rosenburg Road, East Marion, NY, 11939 Attn.: To Whom It May Concern Observation of the condition of the existing framing system was performed by an audit team of Element Energy LLC. After review of the field observation data, structural capacity calculations were performed in accordance with applicable building codes to determine adequacy of the existing roof framing supporting the proposed panel layout. Please see full Structural Calculations report for details regarding calculations performed and limits of scope of work and liability. The design criteria and structural adequacy are summarized below: Design Criteria Code: 2020 NYSBC, ASCE 7-16 Risk Category: II ctaF NEW y Ult Wind Speed: 127.0 mph 01Hgsy�O.p� Ground Snow: 25.0 psf Min Snow Roof: N/A w y v 101242 pR�F $S p a� Current Renewables Engineering Inc. Exp.05/31/ 7 Professional Engineer STAMPED 06/04/2025 info@currentrenewableseng.com 3600 Lime St Bldq 2,Ste#224, Riverside,CA 92507 (951)203-5933 info(a)currentrenewablesenq.com Page 2 of 2 Summaries: Check 1: Metal roofing supported by 2x8 Rafter @ 16 in. OC spacing. The roof is sloped at approximately 37 degrees and has a max beam span of 12.0 ft between supports. Roof is adequate to support the imposed loads. Therefore, no structural upgrades are required. Check 2: Metal roofing supported by 2x8 Rafter @ 16 in. OC spacing. The roof is sloped at approximately 14 degrees and has a max beam span of 15.0 ft between supports. Roof is adequate to support the imposed loads. Therefore, no structural upgrades are required. 3600 Lime St Bldq 2,Ste#224, Riverside, CA 92507 (951)203-5933 info(acurrentrenewablesenq.com ��,OF NEWY ROOF MOUNT SOLAR PERMIT PACKAGE h'tQ polHgs O� ROCKY BLUFF LLC C W 20.010 KW DC GRID TIED PHOTOVOLTAIC SYSTEM ysFo 101242 _ 645 ROSEN BU RG RD, EAST MARION, NY 11939 Exp.05/31/ 7 STAMPED 06/04/2025 AERIAL VIEW VICINITY VIEW CODE INFORMATION GENERAL NOTES THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW.REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT THE INSTALLATION OF SOLAR ARRAYS AND PHOTOVOLTAIC PRIOR WRITTEN APPROVAL FROM CURRENT 1. LOCAL UTILITY PROVIDER SHALL BE NOTIFIED PRIOR TO USE AND ACTIVATION OF ANY RENEWABLES ENGINEERING INC. POWER SYSTEMS SHALL COMPLY WITH THE FOLLOWING CODES: SOLAR PHOTOVOLTAIC INSTALLATION 2020 BUILDING CODE OF NEW YORI<STATE 2. THIS PROJECT SHALL COMPLY WITH LOCAL ORDINANCES 11\ 3. PROPER ACCESS AND WORKING CLEARANCE WILL BE PROVIDED Current 2020 RESIDENTIAL CODE OF NEW YORK STATE 4. ALL ELECTRICAL WORK SHOWN ON THESE PLANS WILL BE COMPLETED BY THE 2020 EXISTING BUILDING CODE OF NEW YORK STATE UNDERSIGNED- Re'newaO°P{}� e"� 2020 FIRE CODE OF NEW YORK STATE 5. ALL APPLICABLE PV EQUIPMENT LISTED AND COMPLIANT WITH UL2703,UL1741 AND Engineering 2020 PLUMBING CODE OF NEW YORK STATE UL1703 20 MECHANICAL CODE NEW YORK STATE 2017 NEW YORK STATE ELECTRICAL 6. ALL ROOF PENETRATIONS TO BE SEALED WITH A HIGH PERFORMANCE ROOF SEALANT CURRENT RENEWABLES ENGINEERING INC. ' 17 3600 Lime Street,Bldg 2 R vemide,CA 92501 r SUCH AS GEO CEL 2300 CLEAR SEALANT Email:Pmjects@creng.solar . ` 7. THE SYSTEM WILL NOT BE INTERCONNECTED UNTIL APPROVAL FROM THE LOCAL Weesite:vmv.=ng.co n JURISDICTION AND THE UTILITY IS OBTAINED PHONE: 951)-204-5492 AHJ: TOWN OF SOUTHOLD 8. THE SOLAR PHOTOVOLTAIC INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING, ' MECHANICAL,OR BUILDING ROOF VENTS CONTRACTORINFO' f' f 9. IF THE EXISTING MAIN PANEL DOES NOT HAVE VERIFIABLE GROUNDING ELECTRODE,IT } i9 ( IS THE NECESSARY TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE ids ,a. LEGEND 10. EACH MODULE WILL BE GROUNDED UL 2703 OR UL 1703 APPROVED USING THE fr , jlgl SUPPLIED CONNECTION POINTS IDENTIFIED ON THE MODULE AND THE Assn* 1 g 5 uM UTILITY METER PM PRODUCTION METER MANUFACTURER'S INSTALLATION INSTRUCTIONS C�SYS0 0 11. A LADDER SHALL BE IN PLACE FOR THE INSPECTION IN COMPLIANCE WITH OSHA MAIN SERVICE PANEL INV INVERTER REGULATIONS' ELEMENT ENERGY LLC. 12. MAX HEIGHT OF MODULES OFF OF ROOF FACE:<6"- 7470 SOUND AVENUE,MATTITUCK, BUILDING INFORMATION 13. PHOTOVOLTAIC SYSTEM WILL COMPLY WITH 2O17 NEC. NEWYORK,11952 COMBINER sus SUB PANEL PH:(631)779 7993 14. PHOTOVOLTAIC SYSTEM INVERTER IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY services@e2sys.com MAIN BREAKER 2 STORY HOUSE SINGLE FAMILY RESIDENCE MBE ENCLOSURE LP BACKUP LOAD PANEL GROUNDED IN THE INVERTER,AND SYSTEM COMPLIES WITH 690.35. (MASTERELECTRIC�AN) 15. MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. License-HI-67461 �C AC DISCONNECT IQ IQ CONTROLLER 2 16. INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. (SUFFOLKHOME IMPROVEMENT) CONSTRUCTION TYPE: V-B OCCUPANCY: R3/U 17. ELECTRICAL EQUIPMENT AND MATERIAL TO BE LISTED,LABELED,AND INSTALLED PER ❑ MODULE An BATTERY THE NEC,THE INSTALLATION STANDARDS/MANUFACTURER'S RECOMMENDATIONS AND ROCKY BLUFF LLC IF REQUIRED A RECOGNIZED ELECTRICAL TESTING LABORATORY.- APN : 1000021000100020000 O ROOF OBSTRUCTIONS 18. CONDUITS EXPOSED TO SUNLIGHT ON ROOF SHALL BE LOCATED NOT LESS THAN 7/8" 645 ROSENBURG RD,EAST QH® Q.HOME HUB ABOVE ROOF SURFACE.SKYLIGHT MARION,NY 11939 SHEET INDEX 19. IN EXPOSED LOCATIONS,WIRING AND CABLING SHALL BE IN CONDUIT OR CABLE SHALL AC ESS DISCONNECT BE RATED FOR EXPOSURE;TYPE NM CABLE ALLOWED IN PROTECTED LOCATIONS. AHJ TOWN of SOUTHOLD PV-1.0 COVER PAGE 36"ACCESS PATHWAYS WITHIN ATTIC SPACES,ALLOWED TO RUN TYPE NM(ROMEX)10/3 OR 12/3 CONDUCTORS LC LOAD CENTER THROUGH OPEN SPACE OR TYPE THHN IN MINIMUM 3/4"ALUMINUM CONDUIT UTILITY PSEG LONG ISLAND PV-2.0 SITE PLAN ® 18"ACCESS PATHWAYS 20. MATERIALS,EQUIPMENT AND INSTALLATION SHALL COMPLY WITH THE REQUIREMENTS, SEPTIC TANK STANDARDS,RULES AND REGULATIONS OF THE FOLLOWING AND BE MOST SUITABLE PV SUMMARY PV-2.1 ROOF PLAN ROOF ACCESS POINT �SSS LEACH LINES TO THE PURPOSE INTENDED: SYSTEM SIZE (KWDC) STc 435 x as= 0.010 JUNCTION BOX PV-3.0 STRUCTURAL SYSTEM SIZE Prc 404.6 x as= e.6os �B PV-4.0 ELECTRICAL 3LD �j PROPANE TANK (KWAC) : ia.7z QCEL TS AUTOMATIC TRANSFER MODULES 46 M-G2+Q.TRON BLK PV-4.1 ELECTRICAL SLD SWITCH 0 WELL WIND SPEED 127 -G2+435 MICROINVERTER 46 ENPHASE O PV-5.0 BOM © PERMANENT ANCHOR Z POWER LINES SNOW LOAD 25 IQSMC-72-M-US PV-6.0 SIGNAGE & PLACARD NO LADDER ACCESS EXPOSURE CATEGORY D PV-7.0 SPECS+ O TEMPORARY ANCHOR 0 (STEEP GRADE IL INSTALLER LADDER OR GROUND LEVELOBSTRUCTIONS) GAS GAS SHUT OFF Rev Description Date STUB-OUT 0 INITIAL DESIGN 5/2 812 02 5 ❑ H2O WATER SHUT OFF A UPDATED DESIGN 6/4/2025 RESTRICTED ACCESS B OSERVICE DROP PROJECT# NA CONDUIT DATE DRAWN 614/2025 RAIL DRAWN BY E.R -- SEAM SHEET# PV-1.0 ATTACHMENT TITLE COVER PAGE R324.6.1'PATHWAYS: NOT LESS THAN TWO MINIMUM 36-INCH WIDE PATHWAYS ON LEGEND �F,OF NE{yY FROM LOWEST SEPARATE LROOF ROOF EDGE TO RIDGE,SHALL BE PROVIDED ON �•�Q\�,pdIHASO,p� ALL BUILDINGS. * Q� AT LEAST ONE PATHWAY SHALL BE PROVIDED ON THE STREET OR UM UTILITY METER DRIVEWAY SIDE OF THE ROOF.FOR EACH ROOF PLANE WITH A PHOTOVOLTAIC ARRAY,A MINIMUM MSP MAIN SERVICE PANEL n 36 INCH-WIDE PATHWAY FROM THE LOWEST ROOF EDGE TO RIDGE 2f SHALL BE PROVIDED ON THE SAME ROOF PLANE OR STRADDLING 101242 Z THE SAME AND ADJACENT ROOF PLANES.PATHWAYS SHALL BE C❑ COMBINER A OVER AREAS CAPABLE OF SUPPORTING FIRE FIGHTERS PROPERTY LINE MAIN BREAKER ACCESSING THE ROOF.PATHWAYS SHALL BE LOCATED IN AREAS �^ MBE . - WITH MINIMAL OBSTRUCTIONS SUCH AS VENT PIPES,CONDUIT,OR •�� r---------------------------------------I ENCLOSURE MECHANICAL EQUIPMENT. I •` AC DISCONNECT Exp.05/311 7 R324.6.2 SETBACK AT RIDGE: \ ❑ MODULE STAMPED06104/2025 FOR PHOTOVOLTAIC ARRAYS OCCUPYING NOT MORE THAN 33 I �\ C A C U M M B E PERCENT OF THE PLAN VIEW TOTAL ROOF ARE:AMOT LESS THAN AN 16 INCH CLEAR SETBACK IS REQUIRED ON BOTH SIDES OF A i `• I I O ROOF OBSTRUCTIONS THESE DRAWINGS ARE SUBJECT TO COPYRIGHT HORIZONTAL RIDGE. I ` PROTECTION BY US LAW.REPRODUCTION IN • I I SKYLIGHT ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT FOR PHOTOVOLTAIC ARRAYS OCCUPYING MORE THAN 33 1 • I I PRIOR WRITTEN APPROVAL FROM CURRENT PERCENT OF THE PLAN VIEW TOTAL ROOF AREA,NOT LESS THAN A 1 \ I I RENEWABLES ENGINEERING INC. 36-INCH CLEAR SETBACK IS REQUIRED ON BOTH SIDES OF A I \`\ I MSP i 36"ACCESS PATHWAYS HORIZONTAL RIDGE. C.0 \` I I 1 _______________� ® 18"ACCESS PATHWAYS Current R324.6.4 EMERGENCY ESCAPE AND RESCUE OPENING:PANELS o I \\ L_____�__________ AND MODULES INSTALLED ON DWELLINGS SHALL NOT BE PLACED Renewables%/ ACCESS POINT Engineering THE PORTION OF A ROOF THAT IS BELOW AN EMERGENCY ESCAPE ENLARGED VIEW ROOF 1 \\• / AND RESCUE OPENING.A 36-INCH-WIDE PATHWAY SHALL BE / qw PROVIDED TO THE EMERGENCY ESCAPE AND RESCUE OPENING. .• j Y. me CURRENT RENEWABLES ENGINEERING INC. _ /., 3600 Li Street,Bldg 2 Riverside,CA 92501 NOTES: 1 Email:Projects@creng.solar 1. MINOR FIELD ADJUSTMENTS ALLOWED BASED ON ACTUAL 1 / 2Z-1" Website:w .creng.m SITE CONDITION AND MEASUREMENTS. ' `\ PHONE:951 204-5492 2. THE 30 SECOND SHUTDOWN REQUIREMENT IS INCORPORATED ROOF ACCESS , \ CONTRACTOR INFO INTO THE 2017 NEC AND UL STANDARD 1741. • , 3. EXISTING ROOF VENT SHOULD NOT BE COVERED. I \•, \'% i V-117 4° ROOF LINE EP—SYS9 FFH 1 `\ 1 ELEMENT ENERGY LLC. NOTE: o I •• 7470 SOUND AVENUE,MATIITUCK NO FENCES OR GATES SURROUND THE PROPERTY ; 1 NEW YORK 11952 1 PH:(631)779 7993 om n ROOF ACCESS POINT License- License-ME-52689 1 _ (MASTER ELECTRICIAN) 1 •• License-HI-67461 a \ (SUFFOLK HOME IMPROVEMENT) b.J ROCKY BLUFF LLC 9645 DRIVEWAY 645 ROSENBURG RD,EAST \• MARION,NY 11939 _ yL °• AHJ TOWN OF SOUTHOLD `\ g' `\ UTILITY PSEG LONG ISLAND 2 50'-8" 114'-10" \\ PV SUMMARY SYSTEM SIZE `\ (KWDC) STC 435 X 46= 0.010 \• •a. \• / SYSTEM SIZE - - -- - -- -- ROOF OBSTRUCTION ----------------------------------- -- -- - - (KWAC) : 14.72 @240 /I / \ MODULES 46 QCELLSQ. BILK 130'-2" 35 MICROINVERTER 46 ENPHASE 0.O IQBMC-72-M-US STRUCTURAL NOTES: 3"S� �h C7 1.THESE PLANS ARE STAMPED FOR STRUCTURAL CODE COMPLIANCE OF THE ROOF •`� �V FRAMING SUPPORTING THE PROPOSED PV INSTALLATION ONLY. /\ �� Rev Description Date 2.THESE PLANS ARE NOT STAMPED FOR WATER LEAKAGE. D INITIAL DESIGN 5/28/2025 3.PV MODULES, RACKING,AND ATTACHMENT COMPONENTS MUST FOLLOW O� A UPDATED DESIGN 6/412025 MANUFACTURER GUIDELINES AND REQUIREMENTS. B 4.PLEASE SEE THE ACCOMPANYING STRUCTURAL CALCULATIONS REPORT FOR PROJECT# NA ADDITIONAL INFORMATION. DATE DRAWN 6/4/2025 SITE PLAN 5.PRIOR TO COMMENCEMENT OF WORK, THE SOLAR INSTALLER SHALL VERIFY THE ROOF DRAWN BY FIR 1 FRAMING INFO BEFORE INSTALLATION AND NOTIFY THE E.O.R. IF THERE IS ANY SHEET# PV-2.0 SCALE: 1/3211 — 11-011 INCONSISTENCY BETWEEN SITE VERIFICATION AND FOLLOWING:2x8 RAFTERS @ 16"OC TITLE SPACING WITH MAX UNSUPPORTED SPAN EQUAL OR LESS THAN 15 FT. SITE PLAN ARRAY AREA LEGEND of NEW , f ROOF ROOF AZIMUTH #OF AREA AREA AREA AREA ROOF TOTAL uM UTILITY METER *ARRAY ROOF �t�\apJIHASyF�.p �. TILT MODULES (Sq.Ft.) (Sq.Ft.) COVERED BY COVERED BY MSP ARRAY MAIN SERVICE PANEL (/o) ARRAY(/o) W #1 37' 110, 10 210.20 3377 6.22 #2 37' 110, 18 1 378.36 1 3377 1 11.20 c❑ COMBINER yJ'A 101242 ,aC= #3 37' 110, 9 189.18 1 3377 1 5.60 28.63 Be ENCLOSURE $ MAIN BREAKER p S p 1\1 #4 14' 290' 9 189.18 3377 5.60 AC DISCONNECT G C UM MBE MODULE ExP.05/31/ 7 0 ROOF OBSTRUCTIONS STAMPED 06/04/2025 ® THESE DRAWINGS ARE SUBJECT TO COPYRIGHT SKYLIGHT PROTECTION BY US LAW.REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT ilTPRIOR WRITTEN APPROVAL FROM CURRENT 36"ACCESS PATHWAYS RENEWABLES ENGINEERING INC. ® 18"ACCESS PATHWAYS Current ROOF#3 RAIL Renewables SEAM Engineering ATTACHMENT CURRENT RENEWABLES ENGINEERING INC. 3600 Lime Street.Bldg 2 Riverside.CA 92501 Email:Projects@creng.solar W�bsle:w .creng.w PHONE:951 204-5492 CONTRACTORINFO (N)46 QCELLS Q.TRON BLK M-G2+435 ROOF#4 ROOF#2 lm®n o EZSYSS ELEMENT ENERGY LLC. n 7470 SOUND AVENUE.MATf1TUCK NEW YORK 11952 PH:(631)779 7993 services@e2sys.com License-ME-52699 (MASTER ELECTRICIAN) License-HI-67461 Z (SUFFOLK HOME IMPROVEMENT) LU N ROCKY BLUFF LLC 0 645 ROSENBURG RD,EAST MARION,NY 11939 AHJ TOWN OFSOUTHOLD UTILITY PSEG LONG ISLAND ROOF#1 PV SUMMARY SYSTEM SIZE(KWDC) STC 435 X 46= D.010 PTC 404.E IX 146 I=118.609 SYSTEM SIZE 14.72 @240 (KWAC) MODULES 46 QCELLS Q.TRON BLK M-G2+435 MICROINVERTER 46 ENPHASE IQBMC-72-M-US Rev Description Date 0 INITIAL DESIGN 5/28/2025 A UPDATED DESIGN 6/4/2025 B PROJECT# NA DATE DRAWN 6/4/2025 DRAWN BY ER 2 ROOF PLAN SHEET# PV-2.1 TITLE SCALE: 3/32" = V-011 ROOF PLAN TABLE 1 TABLE 2 - OF NEWYp s1 FRAMING TYPE RAFTER ROOF ROOF ROOFING FRAMING FRAMING OC MAX PENETRATION MAX a,'� `�,,p.s HAsyf, ;Pl NO. TILT TYPE TYPE SIZE SPACING SPACING OVERHANG sz ATTACHMENT S-5-U CLAMP 0 tt 1t 1r �� ROOF 1 37 STANDING SEAM METAL RAFTER 2 X8 16 32 24 75 r w s3 RAIL IRONRIDGE AIRE Al RAIL It �1 1611 32" 2411 ROOF 2 37 STANDING SEAM METAL RAFTER 2 XS %� 101242 ROOF 3 370 STANDING SEAM METAL RAFTER 2"X8" 1611 32" 24" ROOF 4 140 STANDING SEAM METAL RAFTER 211X8" 16" 3211 24" rJ(P.os/sv 7 SEAM SPACING: 16 INCH STAMPED 06/04/2025 THESE DRAWINGS ARE SUBJECTTO COPYRIGHT WIND SPEED 127 PROTECTION BY US LAW.REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT SNOW LOAD 25 PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. EXPOSURE CATEGORY D Current Renewabtes Engineering CURRENT RENEWABLES ENGINEERING INC. 3600 Lime Stmet,Bldg 2 Riverside,CA 92501 MID AND END CLAMP Email:Projects@crengsolar Nkbsite:www.raeng.co _ PHONE: 951 204-5492 MODULE MODULE CONnIACTOR INFO S3 S3 L-FOOT TABLE : PENETRATION CZSYSu L-FOOT GUIDE FOR INSTALL 5+2 ELEMENT ENERGY LLC. 82 TWO OR MORE ROWS OF PANELS 747o SOUND AVENUE. 11952TTITUCIc PH:(631)779 7993 services@e2sys.com License-ME-52689 ROOF (MASTER ELECTRICIAN) License-HI-67461 (SUFFOLK HOME IMPROVEMENT) S, ROOF I I I I I I I I I I I I I I I I I I I I 0.9" 3/8-24 STAINLESS I I I I I I I I I I I I I I I I I I I I ROCKY BLUFF LLC M8-1.25 16MM STAINLESS STEEL ROUND POINT 6asnaARlory niYsi939EAST STEEL HEX FLANGE BOLT SETSCREW (16 HEX DRIVE) I I I I I I I I I I I I I I I I I I I I AHJ TOWN OFSOUTHOLD s, ( I I I I I I I I I I I I I I I I I I I ENLARGEVIEW UTILITY PSEG LONG ISLAND PV SUMMARY 3"MIN- STACKED STAGGERED FULLY STAGGERED SYSTEM SIZE L-FOOT 6"MAX (KWDC) STC 435 X 46= 0,010 PTC 404.6 X 46= 8.609 - SYSTEM SIZE 14 72 @240 ONE ROW OF PANELS (KWAC) - - - MODULE ---- —- - — - - - -- ---- - —' - - - M N BLK MODULES CE2+435 RO -G2+435 MICROINVERTER 46 ENPHASE IQSMC-72-M-US I I I I I I I I I I I I I ROOF I I I I I I I I I 1 I 3"MIN- 6"MAX FULLY STAGGERED STACKED/STAGGERED Rev Description Date 0 INITIAL DESIGN 5282025 0.9" 3/8-24 STAINLESS STEEL A UPDATED DESIGN 6I4I2025 B SEE ENLARGE VIEW ROUND POINT SETSCREW (16 HEX PROJECT# NA DRIVE) DATE DRAWN 61412025 DRAWN BY ER SHEET# PV-3.0 TITLE ATTACHMENT DETAIL STRUCTURAL BACKFEED FUSE SIZING NOTE: MAX.CONTINUOUS OUTPUT 1.33A @ 240V ELECTRICAL EQUIPMENT LIST 1)CONDUITAND CONDUCTORS SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS OF N� AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. �e l'I/ 61.18 X 1 1.25 = 76.48AMPS 80A FUSES-OK S.NO. ITEMS DESCRIPTION CITY. 2)ALL CONDUCTORS NOT UNDER ARRAY ARE TO BE IN CONDUIT MINIMUM 7/8"ABOVE ROOF WITH CD p.EL A/J� yo 1 PV MODULE QCELLS Q.TRON BLK 46 PROPER JUNCTION BOX AT EACH END PER 690.31A M-G2+435 MODULE QCELLS 2 MICROINVERTER ENPHASE IQ8MC-72-M-US 46 sealed 05jun2025 r It K: _ F MANUFACTURER mike@h2dc.com Hurricane Hill MODULE MODEL Q.TRON BLK M-G2+435 V. 3 COMBINER ENPHASE IQ COMBINER 6C 1 UTILITY - PSGELI Development Company 100A RATED D223NRB ACCOUNT NO. - 9674947302 PLLC C ,off° `748a � MODULE(W) 435 4 AC DISCONNECT SQUARE D KNIFEBLADE 1 NY CoA#: PB-082933 D'SSIOlvek MODULE PTC(W) 404.55 LOCKABLE NEMA 311 UL METER NO.- 98530865 ELECTRICAL ONLY LISTED - MODULE Isc(A) 13.82 PRE-CONSTRUCTION MODULE Voc V 39.60 NOTE:THE CONNECTION BETWEEN THE PV PANEL DRAWING SET- THESEECTIONBYUSLAW.GS ARE SUBJECTREPRODUCTION ( ) (E) UTILITY METER TO UTILITY PROTECTION BY US LAW.REPRODUCTION IN AND MICROINVERTER IS VIA MC4 CABLE,WHICH IS ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT - MODULE Imp(A) 13.13 GRID PRIOR WRITTEN APPROVAL FROM CURRENT PRE-INSTALLED BY THE MANUFACTURER. RENEWABLES ENGINEERING INC. MODULE Vmp(V) 33.14 (N) ENPHASE (E)20OAl2P MAIN BREAKER Current COMBINER BOX 6C ENCLOSURE RenewaWe5 2 r y y Engineering CELL WIRE LESS CURRENT RENEWABLES ENGINEERING INC. MODEM COMMS (E)200A/2P MAIN 3600 Lime Stmet,Bldg 2 Riverside,CA 92501 BREAKER Emil:Projects@creng.solar BRANCH 1 OF 12 (TOP FED) PHONE,(951}204-n5492 PV MODULE N IQ GATEWAY (N)15A IQ GATEWAY T BREAKER CONTRACTORINFO TO MSP BRANCH 2 OF 12 (N)2OAm r —) PV MODULE NT I (N)2oA/I� i i (N)LINESIDE TAP VIA UL E25YSLI /'� BRANCH 3 OF 11 N � I I LISTED CONNECTOR ELEMENT ENERGY LLC . ( LA. � A 7470 SOUND AVENUE,MATTI TUCK, r NEWYORK 11952PV MODULE T I I N f r--- 1II LII IIII--- (Nct)FUSED (N)20A AC DISCONNECT CT (N)80A FUSE services@e2sys.com Uese-ME-62489 MASTER ELECTRICIA N) License- 61 BRANCH 4 OF 11 O (SUFFOLK HOMEIMPROVEM EN PV MODULE ---------- L-------- �------�--- ---- L---------pM ) ROCKY BLUFF LLC I 645 ROSENBURG RD,EAST C L----- --------- MARION,NY 11939 3 B i AHJ TOWN OFSOUTHOLD GEC COATED --� MAIN BONDING JUMPER NOTE: #6AWG TO THE (E)GROUNDING ELECTRODE _ UTILITY PSEG LONG ISLAND MAIN GROUND ROD IN CONDUCTOR #6 BARE COPPER PV SUMMARY EGC AT ARRAY SHALL BE PROTECTED FROM PHYSICAL DAMAGE TO WATER MAIN SYSTEM SIZE (KWDC) STC 435 X 46= 0.010 PTC 404.6 IX1461=18.609 SYSTEM SIZE 14.72 @240 _WIRE CALCULATION (KWAC) MODULES 46 QCELLS Q.TRON BLK STARTING ADJUSTMENT MAXIMUM ENPHASE 35 STARTING TEMPERATURE MICROINVERTER 46 ENPHASE CONDUCTOR CONDUCTOR CONDUIT ALLOWABLE TEMPERATURE CURRENT CORRECTION FACTOR FOR ADJUSTED CURRENT IQBMC-72-M-US TAG DESCRIPTION APPLIED TO MORE THAN 3 CONDUCTOR APPLIED TO QTY. SIZE(AWG) SIZE&TYPE AMPA RATING (°C) CONDUCTORS FACTOR CONDUCTORS AMPACITY CONDUCTORS 310.15(B)(1)(16) IN RACEWAY 310.15(B)(2)(a) 310.15(B)(3)(a) IN RACEWAY SKU: Q-12-RAW-300, THHN A 2 12 N/A FREE AIR 30 90° 15.96 0.96 1 28.80 19.95 1 8 BARE COPPER-(GROUND) Rev 0 INITIAL Description Date IAL DESIGN 5I28/2025 3 4 THWN-2 COPPER-(L1,L2,N) A UPDATED DESIGN 6/4/2025 B V PVC 95 90° 61.18 0.96 1 91.20 76.48 B 1 8 THWN-2 COPPER-(GROUND) PROJECT# NA 3 4 THWN-2 COPPER-(L1,L2,N) DATE DRAWN 6/412025 C 1" PVC 95 90° 61.18 0.96 1 91.20 76.48 DRAWN BY E.R 1 6 THWN-2 COPPER-(GROUND) SHEET# PV4.0 TITLE ELECTRICAL 3LD BACKFEED FUSE SIZING NOTE: MAX. CONTINUOUS OUTPUT 1.33A @ 240V ELECTRICAL EQUIPMENT LIST 1)CONDUITAND CONDUCTORS SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. OF NE�,y 61.18 X 1.25 = 76.48AMPS 80A FUSES-OK S. NO. ITEMS DESCRIPTION CITY. 2)ALL CONDUCTORS NOT UNDER ARRAY ARE TO BE IN CONDUIT MINIMUM 7/8"ABOVE ROOF WITH 1 PV MODULE QCELLS Q.TRON BLK 46 PROPER JUNCTION BOX AT EACH END PER 690.31A S APE MeG,o�� M-G2+435 MODULE QCELLS 2 MICROINVERTER ENPHASE IQ8MC-72-M-US 46 sealed 05jun2025 r MANUFACTURER _ a K,' PT mike@h2dc.com 3 COMBINER ENPHASE IQ COMBINER 6C 1 Hurricane Hill MODULE MODEL Q.TRON BLK M-G2+435 UTILITY - PSGELI Development Company 100A RATED D223NRB C� MODULE(W) 435 SQUARE D KNIFEBLADE ACCOUNT NO. - 9674947302 PLLC „. a8748 1 4 AC DISCONNECT LOCKABLE NEMA 3R UL 1 METER NO, 98530865 NY CoA#: PB-082933 C�SS1 - MODULE PTC(W) 404.55 LISTED ELECTRICAL ONLY MODULE Isc(A) 13.82 PRE-CONSTRUCTION MODULE Voc(V) 39.60 NOTE:THE CONNECTION BETWEEN THE PV PANEL (E) UTILITY METER TO UTILITY DRAWING SET- THESE DRAWINGS LA ARE W.REPRODUCT�IGNr AND MICRO-INVERTER IS VIA MC4 CABLE,WHICH IS ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT MODULE Imp(A) 13.13 GRID PRIOR WRITTEN APPROVAL FROM CURRENT PRE-INSTALLED BY THE MANUFACTURER. RENEWABLES ENGINEERING INC. MODULE Vmp(V) 33.14 (N) ENPHASE (E)200A/2P MAIN BREAKER Current COMBINER BOX 6C ENCLOSURE Renewables 2 A Engineering CELL WIRELESS MODEM COMMS (E)200A/2P MAIN CURRENT30 ima Street BIddgL2 Riveerside,ENGINEERING INC. BREAKER Email:Projects@creng.solar BRANCH 1 OF 12 (TOP FED) PHONE:(951}zo-54e PV MODULE ANV IQ GATEWAY (N)15A IQ GATEWAY BREAKER CONTRACTORINFO • TO MSP BRANCH 2 OF 12 (N)20A • • PV MODULE N• '�• (N)20:�. EZSYSU (N)LINESIDE TAP VIA UL BRANCH 3 OF 11 (N)20A LISTED CONNECTOR ELEMENTENERGY LLC. •1• 4 7470 SOUND AVENUE,MATTITUCK. PV MODULE <N� / ` (N)FUSED PH: 11952 (N)20A/1\ AC DISCONNECT (N)80A FUSE services@e2sys.com •/�• License-ME-52689 (MASTER ELECTRICIAN) BRANCH 4 OF 11 License-HI-67461 PV MODULE N (SUFFOLK HOME IMPROVEMENT) • 0.I�� ROCKY BLUFF LLC 645 ROSENBURG RD, EAST C MARION,NY 11939 3 B AHJ TOWN OFSOUTHOLD UTILITY PSEG LONG ISLAND NOTE: (E)GROUNDING ELECTRODE _ EGC AT ARRAY SHALL BE PROTECTED FROM PHYSICAL DAMAGE CONDUCTOR #6 BARE COPPER — PV SUMMARY SYSTEM SIZE : STC 435 X 46= 0.010 (KWDC) PTC 404.6 X 46=18.609 SYSTEM SIZE 14.72 @240 _ WIRE CALCULATION (KWAC) MODULES 46 QCELLS Q.TRON BLK STARTING ADJUSTMENT MAXIMUM ENPHASE 35 STARTING TEMPERATURE MICROINVERTER qg ENPHASE CURRENT FACTOR FOR ADJUSTED CURRENT IQ8MC-72-M-US CONDUCTOR CONDUCTOR CONDUIT ALLOWABLE TEMPERATURE CORRECTION TAG DESCRIPTION APPLIED TO MORE THAN 3 CONDUCTOR APPLIED TO QTY. SIZE(AWG) SIZE&TYPE AMPA RATING (°C) CONDUCTORS FACTOR CONDUCTORS AMPACITY CONDUCTORS 310.15(B)(1)(16) IN RACEWAY 310.15(B)(2)(a) 310.15(B)(3)(a) IN RACEWAY SKU: Q-12-RAW-300, THHN A 2 12 N/A FREE AIR 30 90° 15.96 0.96 1 28.80 19.95 1 8 BARE COPPER-(GROUND) Rev 0 INITIAL DESIGN Date IAL 5/28I2025 3 4 THWN-2 COPPER-(L1,L2,N) A UPDATED DESIGN 614/2025 B 1rr PVC 95 90° 61.18 0.96 1 91.20 76.48 B 1 8 THWN-2 COPPER-(GROUND) LDATE CT# NA RAWN 6/4/2025 3 4 THWN-2 COPPER-(L1,L2,N)C 1rr PVC 95 90° 61.18 0.96 1 91.20 76.48 BY E.R 1 6 THWN-2 COPPER-(GROUND) # PV-4.1 TITLE ELECTRICAL SLD MATERIAL LIST ELECTRICAL EQUIPMENTS QTy• PART TYPE PART NUMBER DESCRIPTION 46 MODULE Q.TRON BLK M-G2+435 QCELLS Q.TRON BLK M-G2+435 46 MICROINVERTER IQ8MC-72-M-US ENPHASE IQ8MC-72-M-US 1 COMBINER X-IQ-AM1-240-6C EN PHASE IQ COMBINER 6C 1 AC DISCONNECT D223NRB 100A RATED 240VAC NEMA 311 UL LISTED 2 TAP CONNECTORS IPC TAP IPC INSULATION PIERCING CONNECTORS THESE DRAWINGSUS LAW.IPRODUCTIONCT TO IN PROTECTION BY US LAW.REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. Current Renewables Engineering CURRENT RENEWABLES ENGINEERING INC. 3600 Lime S1reel.Bidg 2 Riverside,CA 92501 Email:Projects@caengsolar Webstte:v1mv creng.ao PHONE:951 204-5492 CONTRACTORINFO BREAKER/ FUSES QTy• PART TYPE PART NUMBER DESCRIPTION EZSYS ELEMENT ENERGY LLC. 4 COMBINER BREAKER 20A 2-POLE BREAKER(S) GENERAL 20A 2-POLE BREAKER(S) 74705o1NE AVENUE,MArnTUCK NEW YORK 11952 PH:(631)779 7993 2 FUSES 80A FUSES GENERAL 80A FUSES License- License-ME-52689 (MASTER ELECTRICIAN) License-HI-67461 (SUFFOLK HOME IMPROVEME" ROCKY BLUFF LLC 645 ROSENBURG RD,EAST. MARION,NY 11939 RACKING AHJ TOWN OFSOUTHOLD QTy. PART TYPE PART NUMBER DESCRIPTION UTILITY PSEG LONG ISLAND 46 RAILS & SPLICES AE-Al-170B AIRE RAIL Al, BLACK, 170" SYSTEM SIZE PVSUMMARY (KWDC) STC 435 X 46= 0.010 18 RAILS & SPLICES AE-A1TIE-01-M1 AIRE TIE, Al (BONDED SPLICE) PTC 404.E x 46=18.609 SYSTEM SIZE 14.72 @240 AIRE LOCK MID,-BLACK 30MM -40MM (KWAC' --- 64 - - - - CLAMPS & GROUNDING---- - - - AE-MID-01-B1- ------ -- -- -- --- - - - - --- - ( ) -- ---- -- -- - - - - MODULES 46 QCE(15Q.TRONBLK 56 CLAMPS & GROUNDING AE-END-01-B1 AIRE LOCK END BLACK (30MM -40MM) NPHASES MICROINVERTER 46 IQ8MC-72-M-US 14 CLAMPS & GROUNDING AE-LUG-01-M1 AIRE LUG 202 ATTACHMENTS LFT-03-B1 SLOTTED L-FOOT, BLACK 202 ATTACHMENTS AE-DOCK-02-B1 AIRE DOCK, BLACK 202 ATTACHMENTS S-5-U S-51 S-5-U CLAMP Rev Description Date 0 INITIAL DESIGN 5128/2025 A UPDATED DESIGN 6/42025 B PROJECT# NA DATE DRAWN 6/42025 DRAWN BY ER SHEET# PV-5.0 TITLE BOM CAUTION sealed 05jun2025 mikm OF NSP PHOTOVOLTAIC — I\/I Hurricane Hill om SEl- Mc • , , • V MULTIPLE SOURCES OF POWER Development Company G� CG F_ PLLC NY CoA#: PB-082933 ELECTRICAL ONLY o t ��y Pn 690.12 PV ARRAY PRE-CONSTRUCTION _ DRAWING SET- ���,o Q8,48 c`�\ �OSS10C:��'� TURN RAPID LDISCONNECT THESE DRAWINGS ARE SUBJECT TO COPYRIGHT _ SHUTDOWN SWITCH TO RATED ACOUTPUT CURRENT • • ` ■ PROTECTION BY US LAW.REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT �� NORMAL J PRIOR WRITTEN APPROVAL FROM CURRENT �� THE OFF POSITION TOAC OPERATING • • Vr RENEWABLES ENGINEERING INC. SHUT DOWN PV SYSTEM 690.14,690.15,690.54 co AND REDUCE SHOCK WARNING LU Rey w�bles HAZARD IN THE ARRAY DUAL POWER SOURCES Engineering 690.56(C)(1)(B) SECOND • ■ PHOTO—VOLTAIC CURRENT RENEWABLES ENGINEERING INC. 3600 Lime StreeLBIdg 2 Riverside,CA 92501 ■ , OUTPUT ■ CURRENT ■ • •. ■ Email:PrejecLs@crengsolar AC Website:vrvrx.uen9 co M AC NORMAL • ■ VOLTAGE VOLTS240 PHONE: 951 2Da-5492 CONTRACTORINFO 690.54 — — OPTIONAL SOLAR LOAD CENTER 0 0 R ARAY EZSYSU ELEMENT ENERGY LLC. MAIN SERVICE PANEL 7470 SOUND AVENUE,MATIITUCK NEW YORK 11952 PH:(631)779 7993 services@e2sys.com MAIN BREAKER COMBINER License-ME-52699 I ENCLOUSRE (MASTER ELECTRICIAN) AC DISCONNECT License-HI-67461 UTILITY METER (SUFFOLKHOME IMPROVEMENT) • � _ � INVERTEROUTPUT CONNECTIONI I PHOTOVOLTAIC BACK-FED CIRCUIT BREAKER IN MAIN ELECTRICAL ROCKY BLUFF LLC • • • I I PANEL IS AC DISCONNECT PER NEC690.17 645 ROSENBURG RD, EAST NEC 690.31(G)(3)&(4),CRC R324.7 MARION,NY 11939 OVERCURRENT DEVICE "WARNING" � AHJ TOWN OFSOUTHOLD (UNLESS BUSBAR IS FULLY RATED) L — 705.12(D)(2) PHOTOVOLTAIC • ' • ■ UTILITY PSEG LONG ISLAND PV SUMMARY EVERY 10'ON CONDUIT AND ENCLOSURES SYSTEM SIZE(Kwoc) STC 435 x as= o.010 NOTES APPENDIX(AS APPLICABLE FOR TO BE BUILT DRAWING SETS) A ( ) SYSTEM SIZE TOTAL AC VOLTAGE DROP NOT TO EXCEED 2%TO PTc 404.6 x 46 = 8.609 ELECTRIC SHOCK HAZARD - _ INTERCONNECTION,<3%FROM INVERTER(S)TO UTILITY TRANSFORMER.(B)ALL CONNECTORS 75C RATED.(C)ALL (KwAc) 14.72 @240 CONDUCTORS COPPER,UNLESS OTHERWISE NOTED.(D)OUTDOOR EQUIPMENT NEMA3R.(E)ALL CONDUCTORS MUST BE MODULES qg QCEUSQ.TRON BLK ( ) 00 NOT TOUCH TERMINALS PROTECTED FROM ACCESS BY A FENCE OR SUITABLE COVER,OR OUT OF REACH. F PROPERTY LINES,BOUNDARIES AND M-G2+435 TERMINALS ON BOTH LINE 3 LOAD SIDES ' MICROINVERTER 46 ENPHASE MAYBE ENERGIZED IN OPEN POSITION t ALL OTHER EXTERIOR MEASUREMENTS ARE FOR REFERENCE ONLY,AND MUST BE VERIFIED BY A LICENSED SURVEYOR OR IQBMC-72-M-US DO NOT DISCONNECT FUSES UNDER LOAD CIVIL ENGINEER. (G)NO PVC ALLOWED ON ROOF OR IN ATTIC. (H)MC4 CONNECTORS MAY NOT BE JOINED WITH'MC4 THE DC CONDUCTORS OF THIS COMPATIBLE'CONNECTORS.(1)TAP CONNECTIONS IN PANEL MUST NOT VIOLATE CONDITIONS OF ACCEPTABILITY FROMPHOTOVOLTAIC SYSTEM ARE NOTES: UNGROUNDED AND MAYBE ENERGIZED I PANEL MANUFACTURER'S NRTL LISTING,OR FIELD LABEL REQUIRED.(J)PV WIRES MAY NOT BE LAID DIRECTLY ON ROOF. PHOTOVOLTAICSYSTEM I (K)TY WRAPS FOR WIRE MANAGEMENT MUST BE STRUCTURAL(S21)UL APPROVED,OR EQUAL.(L)DRAWINGS ARE DC DISCONNECT DIAGRAMMATIC AND INDICATE GE-NERAL ARRANGEMENT OF SYSTEMS AND WORK.-CONDUIT ROUTING,WHEN INDICATED, 1. NEC ARTICLES 690 AND 705 AND NEC SECTION R324 MARKINGS AUTHORIZED PERSONNEL ONLY ! DOES NOT SHOW ALL OFFSET8S,DROPS,AND RISES OF RUNS.(M)BURIED CONDUITS UNDER AREAS SUBJECT TO VEHICLE SHOWN HEREON. I TRAFFIC REQUIRE MIN 24"COVER. (N)NM-B OR PAPER INSULATED CONDUCTORS MAY NOT BE USED EXTERIOR. (0)THE 2, ALL MARKING SHALL CONSIST OF THE FOLLOWING: Rev Description Date Note:WARNING labels must resemble format DEVELOPER IS REQUIRED TO CONFIRM EXISTING ELECTRICAL SERVICE SIZE FROM THE UTILITY,AND MAY NOT RELY A. UV RESISTANT SIGN MATERIAL WITH ENGRAVED OR 0 INITIAL DESIGN s/zs/zozs in example above over-sized WARNING, S-OLELY ON EXISTING BREAKER SIZES.(P)CONNECTING TO UTILITY EQUIPMENT REQUIRES PRIOR UTILITY CONSENT.(Q) p WHEN BUILDING PV SYSTEMS WITH POWER LINE COMMUNICATIONS FOR RSD SOLUTIONS,FOLLOWING MANUFACTURERS MACHINE PRINTED LETTERS OR ELECTRO-PLATING. A UPDATED DESIGN 6/anozs exclamation point in triangle,colors,etc. INSTRUCTIONS ON CONDUCTOR AND CONDUIT SPACING IS PARAMOUNT,OR HAZARD MAY RESULT.(R)NOTIFY ELECTRICAL B. RED BACKGROUND COLOR WHITE TEXT AND LINE B ENGINEER WHO'S SEAL IS ON THIS DRAWING PRIOR TO ANY AND ALL CHANGES IN DESIGN.(S) PROJECT RELATED LDRAWN NA SIGNAUCOMMUNICATION CONDUCTORS MAY ONLY BE RUN IN THE SAME CONDUIT WITH POWER CONDUCTORS IF THEIR WORK. RATING FOR THE OUTER MOST JACKET IS EQUAL TO OR GREATER THAN THE INSULATION REQUIRED FOR THE HIGHEST C. AERIAL FONT. s/arzoz5 VOLTAGE POWER CONDUCTOR CIRCUIT THAT THEY ARE SHARING THE RESPECTIVE CONDUIT WITH. 3. ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN E.R THE LOCATIONS SPECIFIED.SIGNAGE CANNOT BE PV-6.0 HAND-WRITTEN. TITLE 4. SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH SIGNAGE POP-RIVETS OR SCREWS. Q.TRON BLK QXRON BLK M-G2+ SERIES ■Mechanical Specification M-G2+ SERIES ocells �t Format 67.8In x 44.6 in x 1.18 in(including frame) (1722mmx1134mmx30mm) + - ___._._ _�. , Weight - ---4671bs(2t2kg) ---- - ----- ---- ------- ------ --- .� � - f Front Cover 0.13 in(32 mm)thermally pre-stressed glass with anti-refiection technology 415-440 Wp 1108 Cells Back Cover Composite film O Frame Black anodised aluminium 22.5/o Maximum Module Efficiency/ --- -- ---------- - - Cell 6 x 18 monocrystaliine GANTUM NEO solar half cells THESE DRAWINGS ARE SUBJECT TO COPYRIGHT Junction box 2A9-398in x 12tr236inx D59-071im „ � PROTECTION BY US LAW.REPRODUCTION IN 153-101mm x 32-6Om--n x 75.18mm),Protection CWss IP67,with bypa55 diDd� °E'"�' a'a""eOe� f ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT Cable 4mm'Solar cabta;(+)>68.9in(175Dmm),(-)268.9in(1750mm) ,oq� --- "' RENEWABLES ENGINEERING INC. _MODEL Q.TRON BLK M-G2+ Connector StaubG MC4;IP68 ! Current■Electrical Characteristics POWER cLA55-- ----------- - ---- --- - 415 420- --425- --430 - a35 ----440- R�r'�1�OW� MINIMUMPERFORMANC=ATSTAN'aAp.D TEST CONDITIONS,5TC(POWERTOLERANCE-5W%-04��-�-------.-.�-_____._- Engineer esIng Power at MPP' Pry Im 415 420 425 430 435 440 CURRENT RENEWABLES ENGINEERING INC. CLANTIUM High performance Ocells N-type _ Short Circuit Isc---I ---[A] 13.49 1356 13"66 13.74 13.82 II.90 3600 Lime StreeLBltlg 2 Riverside,CA 92501 N=D C -- - - Email:Projects@cmng.solar solar cells Open Circuit Voltage' Va M 38.47 38.75 39A3 3932 39-60 39.88 Websfte:www.aeng.co CANTUM NEO Technology wilh Optimized module layout _E Current at MPP _ I-- [A] 12.83 12.91 12.98 13.05 1313 _ 1320 PHONE: 95*204-5492 boosts nodule efficiency up to 22-5 Y Voltage at MPP _ V_ M 3234 32.54 _ 32.74 32-94 _ 3314 - 3333 CONTRACTOR I NFO Efficiency' r) [%] 2213 221.5 221.8 M.0 2223 222.5 A reliable investment MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS,NMOTP Inclusive 25-year product v aranty and 25-year linear Power at MPP F_ [W) 3W 3175 3212 325.0 328.8 332.6 ��■■ Waranly performance warrant•,% E Short Circuit Cullen! I- [A] 10.19 10.94 two 1107 1t14 1120 CZ SYS E Open Circuit Voltage Voc [V] 3650 3677 37.04 3731 37.58 37-84 'c f Current at MPP I- [A] 1010 1015 1021 10-27 1033 1038 ELEMENT ENERGY LLC. Enduring high performance Voltage at MPP V_ M 3107 3126 31.46 3165 31.84 32M 7470 SOUND AVENUE,MATTITUCK 'SQI�i) 'Measurement tolerances P,m,±3%;L;;Vm±5%at STC:1000 W/ 7993 rrR,25±2'C,AM)S acing to IEC 60904-3•'80D W.'m{NMOT,spectrum AM 15 H:(Y1)R 7 11952 Long-term yield security with Anti LeTID Technology,Anti PID se PH:es e2s s.co �e s Technologyd,Hot-Spot Protect [-^---------- -- --`- ---�1 Licelnse@ME-52689 `Ocells PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE -�____ _v_ _ ___��___.�-...- -.--- (MASTER ELECTRICIAN) License-HI-67461 At least 965%of nominal power r r r SUFFOLK HOME IMPROVEMENT) Extreme weather rating dudngfnstyear.Themattermax. i t I _________ 033%degmdaBon Per yeas At ° CP Hghtech aluminium alloy frame,certified for i least95.53%ofnominalpower ----- ------ �� upotDyearsAtleast90.58%of w ROCKY BLUFF LLC high snow(8100 Pa)and wind loads(3600 Pa)- o nominal power up to 25 years LLo 645 ROSENBURG RD, EAST LL A0 data within measurement = °O tolerances.Full warantiesto � MARION,NY 11939 r n accordance wren the warranty z Innovative all-weather technology 5 t11 AHJ TOWN OF SOUTHOLD _ u o ®0 6 mg3r sae Ocells sal es n°'your respecWe ,m am ®o m Optimal yields,whatever the weather with excellent low-light r V ` YEARS 1°° IRRADIANCE 0vrm* 11 and temperature behaviour sanaare>�m,my��:eer°.u,esw�..,sw .xu,c� ryRKx�a,mxnol,R, .ro.,N,a�xr�,ra � UTILITY PSEG LONG ISLAND rghmpoCWroncaVanlyM2021(febn . 292y mmOA+tson to STC mrlamora as•e-%xionuml o _ PV SUMMARY n The most thorough testing - - - --- SYSTEM SIZE - g 9 = programme in the industry Temperature Coefficient of Isc D [%i K) +0.04_ Temperature Coefficient of V_ p [%/K] -024 4 (KWDC) sTc 435 X 46 0.010 -�- --- -- -- 109±5A ' PTC 404.6 IX1461= 8.609 Temperature Coefficient of P_ Y [%/K] -030 Nominal Module Operating Temperature NfADT M. (43±3°C) `� SYSTEM SIZE Oceils is the first solar module manufacturer to pass the (KWAC) 14.72 @24o most comprehensive quality programme in the industry,The - - " ' 9 QCELLS Q.TRON BLK new-Quality Controlled PV'of the independent certification ■Properties for System Design a MODULES 46 M-G2+435 institute TOV Rheinland. o` MICROINVERTER : 46 ENPHASE Maximum System Voltage VM M 1000 pEC)/1000(UL) PV module classification Class 11 IQSMC-72-M-US Maximum ieries Fuse Rating [A DC] 25 Fire Rating based on ANSI/UL 61730 C/TYPE 2 +See data vieetonrewfmfu�mermlamatio Max.Design LoadPush/PuIP (Ibs/ftrj 113(5400 Pa)/50(2400 Pa) Permitted Module Temperature -40°Fupto+185'F APT test conht�;% a&-rg to ECfTS 6280412015.method A(-TSOOV,96h) ---_--� -- on Continuous Duty (-40`C up to+85'C) 6 Mex.TestLoed,Push/Pull [IbsJft'] 769(B100Pa)/75(3600Pa) 'See Installation Manual ■Qualifications and Certificates Rev Desc ption Date UL61T30-18 UL61730-2,CEcompfianL 0 INITIAL DESIGN 5/28/2025 Ouallry Controlled PV-TUV Rheinland. �,i A UPDATED DESIGN 6/4/2025 IEC 612152016.IEC 617302016, I �,x}r]Q 1; U.S.Patent No.9.893.215(solar cells). ,,,,,�,,,-, C E B The Ideal solution for. NAO c DATE DRAWN 6/4/2025 mxa us ® 1ao n v PROJECT# NA O Rooftop arrays on "'"°"`° 'Contact your oceils sales Representative for detalls regazdhlg the module's eligibility to be Buy American Act(BAA)compliant a ° r residential buildings USA __-- _ ® -�� DRAWN BY E.R Ocells pursues minimizing paper output in consideration of the global environment. SHEET# PV-7.0 Not ,Ir6}rudioA3 nxbt Sp,o S� .MAm.r,unlxrnJSAI TE-19497�Kau 1L dllspro0°a oeells H.mvoaOCEtLS Amerio lac 30D 5peCrum[irrter Ube.Suite s00,Ir�Ine,CA 926te,115AI TELN9697G85996 iEMlUL nasrypmtpgceescoml Wca rw•w.acer.he TITLE MODULE SPEC ENPHASE. am= IQ8MC Microinverter Commonly used module pairings' IN - 260-460 wModule compatibility To meet compabbTny.PV modules must be within the following max.input DC voltage and max.module I. Module compatibility can be checked at httos://enphase.com/instalWs/MicroirrverteTs/calculator. MPPT voltage mrge V - -25-45 Operating range V 18-58 THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW.REPRODUCTION IN MInJMax.start voltage V 22/58 ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT Max,input DC Voltage V 6o RENEWABLES ENGINEERING INC. Max continuous operating DC current A 14 _ Current '` _ Max input DC short-circuit current A 25 C UIra 1t'e n t} . Max.module1. - A - 20 Renewables O9ervoltage class DC port - - - - - - - - - - It - - - - Engineering DC port backfeedcurrertt MA 0 - CURRENT RENEWABLES ENGINEERING INC. PV array configuration Ungrounded array;no addrtional DC side protection required;AC side protection requires max 20 Aper branch circuit 3600 Lime StmetBldg 2 Riverside,CA 92501 Emil:Pmjects@creng.solar OUTPUT DATA(AC) UNITS IQ8MC-72-M-US @240 VAC 108MC�72-M�US @208 VAC Website:www.crerg.co - PHONE:951)-2045492 Peak output power VA 330 - 315 - - - - CONTRACTORINFO Max continuous output power VA 320 310 Nominal grid voltage(L-U V 240,split-pfiase",180° 208,single-phase(L-L),12D' Q8 M C Microinverter Easy to install Kn./Max gr)d voltage' - V - 211-264 183-229 Our newest 108 Series Microinvetters are the imiustry's first microgrid-forming*,software- Lightweight and compact with plug- Max continuous output current A JZ3 L49 C SYS defined mieroinverters with spfit-phase power conversion capability to convert DC power to and-PlaYconnectors Nominal frequency HE 60 u AC power efficiently.The brain of the semiconductor-based microinverter is our proprietary •Power rme communication(PLC) Hz 47-W application-specific integrated circuit(ASIC),which enables the microinverter to operate in between components Extended freclue'cY range ELEMENT ENERGY LLC. grid-tied Or off-grid modes.This chi is builtin advanced 55-nm technology With high-speed AC short circuit fault current over three 7470 SOUND AVENUE,MATTITUCK g � P °gy g Faster installation with simple two-wire A� 270 NEW YORK 11952 g digital logic and has superfast response times to changing loads and grid events,alleviating cabling cycles PH:(631)779 7993 constraints on battery sizing for home energy systems. _ services@e2sys.com Max.units per 26A(L-L)branch circuit 12 10 License-ME-52699 -' - "- - - - - (MASTER ELECTRICIAN) High productivity and reliability Total hamronicdistortion % <5 License-HI-67461 _ Enphase Produces power even when the grid i.s _ - (SUFFOLK HOME IMPROVEMENT) down' - Overvoltage class AC port More than one million cumulative hours AC port backfeed current mA 18 ROCKY BLUFF LLC of testing Power factor setting' 1A 645 ROSENBURG RD,EAST Part of the Enphase Energy System. IQ8 Series Miaoinverters redefine Class 11 double-insulated enclosure MART O N,NY 11939 P rgY Yst Grid-tied power factor(adjustable) 0.85 leading_0.85 lagging I08 Series Microinverters integrate with reliability standards with more than one -Optimized for the latest high-powered the IQ Battery,IQ Gateway,and the million cumulative hours of power-on PV modules Peak efficiency % - 97A - 97.2 AHJ TOWN OF SOUTHOLD Enphase App monitoring and analysis testing,enabling an industry-leading CEC weighted efficiency % 97.0 96"5 software. limited warranty of up to 25 years - UTILITY PSEG LONG ISLAND MICrO®rid-forming .Nighttime power consumption FEW33 - 25 Compries.with the latest advanced grid MECHANICALPV SUMMARY } support • SYSTEM SIZE STC 435 X 46= 0.010 Ambient temperature range -40'C to 65•C(-40'F to 1497) (KVVDC) .� Remote automatic updates for the - - .6 X 46= latest grid requirements Relative humidity range 4%to 100%(condensing) _ SYSTEM SIZE -FTC-- 404 8.609 • DC connector type Staubll MC4 - (KWAC) : 14.72 Qa 240 Configurable to support a.WldB range --- - . - - - -- - - - - -------- - - - - . Of grid profiles Dimensions(H•W•D}Weight 212 nun(8.3•)•175 mm(6.9•)•302 min(1.2•},11 kg(2"431bs) MODULES 46 QCELLS R•TRDN BILK M-G2+435 Connect PV modules quickly and easily IQ8 Series Microinverters are UL Listed to the IQ8 Series Microinverters that have as PV rapid shutdown equipment and Meets CA Rule 21(UL 1741-SA)and IEEE Cod ENPHASE Cooling Natural convection-ro fans MICROINVERTER 46 ENPHA MC -M-US integrated MC4 connectors. conforms with various regulations when 1547.2018(UL 1741-SB) Approved for wet locations;Pollution degree Yes;PD3 installed according to the manufacturers - instructions. - Enclosure - Class II double-insulated,corrosion-resistarn polymeric enclosure NOTE • 108ISiaoervortene cannot be mixed togetherwith Environ.category;UV exposure rating NEMA Type 6;outdoor previous generatiornsof Errphase rricrokrvertera (Kg Serkm IQe Series,etm)In thosame system "Meets UL 1741 oN when Instased with 10 s b Gateway m required to change the default gdd- 'CA Rule 21(UL 1741-SA),UL 62109-1,IEEE 1547:2018(UL 1741-SB),FCC Part 15Class B,ICES-0003 Class&CAN/CSA-C222 N0.107.1-01 y ystamCorr[ro8er2ard3. protgeatthetfineof Installation to meet the local Certifications This product Is UL Listed as PV rapid shutdown equipment and conforms With NEC 2014,NEC 2017,NEC 2020,and NEC 2023 section 690.12 and Rev Description Date Authority Havang Jurisdiction(AHJ)requirements. C22.1-2018 Rule 64-218 rapid shutdown of PV systems for AC and DC conductors when installed according to the manufacturer's instructions. 0 INITIAL DESIGN 5/2 812 0 2 5 02023 Enphase Energy,A9r(ghts reserved"Fsphase.theeard CC logos,I4andeertain other marks listedat - (1)No enforced DC/AC ratio- A UPDATED DESIGN 61412025 httos!/ermhase.com/trademark-raage�midorm%am tmdemarts of Enphase Energy.lna In the US and other countries. (2)Nominal voltage range can be extended beyond nominal If required by the Utility. Data subject to change. IO8MC-MC4-DSH-00049.3A-EN-US-2023-1G-18 (3)DmMs may vary.Refer to local requirements to define the number of mkroimerters per branch in your area. IO8MC-MC4-DSH-00049-3.0-EN-US-2023-10-18 B PROJECT# NA DATE DRAWN 6/4/2025 DRAWN BY E.R SHEET# PV-7.1 TITLE MICROINVERTER SPEC Product detaif� IQ Combiner QC ENPHASE. NORTH AMERILA. IQ Combiner 6C includes the following components: • IQ Gateway for revenue-grade production and storage metering. • Combiner controller board for safety. QC o m b i n e r 6 C IQ Combiner 6C2 Solar shield and fans to enhance thermal performance. (X-IQ-AM1-240-6C) Integrated Rapid Shutdown initiator for outdoor installs. he IQ Combiner 6C consolidates inters nec6ion equipment into a Integrated and pre-wired current transformers for PV and batteries. -Enphass Mobile Connect cellular modem(CELLMODEM-07-NA). THESE DRAWINGS ARE SUBJECT TO COPYRIGHT single enclosure,streamlining ti)e installation of IQ Series Microinverte S. PROTECTION BY US LAW.REPRODUCTION IN It ante rates the IQ Gatewa to ' e a consistent, ce wired solution Integrated load controller,.with monitoring and control loads. ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT for residential pplieations.lt' udes breaker spaces for PV,battery RENEWABLES ENGINEERING INC. EY a arge, an ntegrated foal controller.Additionally,tt reduces box - stalla' ti ifl ntegratf3d grid e- 'red current transf• rsters for Enclosure IQ Combiner 6C unit Current Pv and ba er es. 'ReneN4 abler Enphase Mobile Connect CELLMODEM-07-NA-3 cellular modem with a 5-year data plan. Engineering IQ Combiner 6C accessory kit including labels,control(GYRE)headers,and the Accessory kit glJ1Ck Install guide(01G). - CURRENT RENEWABLES ENGINEERING INC. 3600 Lime StreeLBldg 2 Riverside,CA 92501 Email:Pmjects@rxengsolar The pre-installed(60 A)UL 489-certified breaker is usable as a Rapid Shutdown Website:www.creng.co Aggregate PV breaker PHONE: 951)-204-5492 initiator if the IQ Combiner 6C is installed at a readily accessible outdoor location. CONTRACTORINFO Key speeffications • ® Sit The integrated IQ Gateway reports production and storage metering,IQ EV Charger, 240 VAC-/-+20% and consumption monitoring,along with IQ Battery and IQ Microinverters data • Integrated"combiner controller IQ Gateway CZ SYS Nominal voltage/Range(L-L) Split-phase(L1-L2 240 V,L-N 120 V, � from the site to the Enphase Cloud.This monitoring and analysis software enables L board(CCB)and IQ Gateway. u 18(r) comprehensive,remote maintenance and management of Enphase systems. - • Includes Enphase Mobile Connect - — - - - - -- - • - (C.•ELLMODEM-07-NA). ELEMENT ENERGY LLC. Nominal frequency/Range 60 Hz/56-63 Hz The integrated DER relay isolates home loads from PV systems and batteries.It 74T0 SOUND AVENUE, LLC. • Supports flexible networking,Wi-F, NEW YORK,11952 PPa Distributed Energy Resource(DER)relay enables the system to automatically recover the State of Charge(SoC)when the PH:(631)779 7993 Maximum continuous PV current 80 A Ethernet,or cellular. I batteries are depleted during off-grid operation. services@e2sys.com (combined) • Integrated revenue-grade. License-ME-52689 (MASTER ELECTRICIAN) production and storage metering A 100 A-PV busbar(for IQ Microinverters)with support for four double-pole breakers License-HI-67ab1 Maximum Continuous battery current 2 59 A Via pre-installed current (SUFFOLK HOME IMPROVEME N" transformers.Also supports for installing IQ Series Microinverters. Maximum continuous EVSE current 1 Y 48 A consumption and EV charger A 200 A DER busbar(forPV,batteries,EV charger,and other home loads)with ROCKY BLUFF LLC monitoring. support for four double=pole breakers for installation: Maximum continuous integrated load 64A DER busbar 645 ROSENBURG RD,EAST controller current Easy Two for IQ Battery 10C. MARI O N,NY 11939 Maximum coritinuous.Distrbuted 1�J One for Enphase EV charger, 160A- Pre-mstalledUL489certified AHJ TOWN OFSOUTHOLD Energy Resources(DERs)current device for Rapid Shutdown. One for aggregate PV(integrated Rapid Shutdown Device). Maximum continuous back-feed current 100 A Single-stud mountable with two Fully integrated meter with solid-core current transformer(CT),accurate up to UTILITY PSEG LONG ISLAND screws. Integrated production metering U to 100 A(ships with 60 A re- ±0.59'0,ANSI C12 20 class 0.5 compliant.Does not require field wiring. PV SUMMARY Maximum aggregate PV breaker size P Ps P Supports multiple conduit entry - SYSTEM SIZE installed breaker)' options such as top side right,top + STC ass x 46= 0.010 - side left,bottom side left,bottom Integrated battery metering 0 5 t ( t Id accurate p o_0.5 SI C12.20 (KWDC) PTC 404.6 x 46= 8.609 Fully integrated meter with two solid-core CTs a u t %,AN 680 mm(26.8")-460 mm(18.11■220 side right,bottom rear,and bottom. class compliant Does no require fie wiring. SYSTEM SIZE 14.72 @240 _ Dimensions(H x W=D) _ _ _ - - - _ - - - ---- — --_ i --- -- (Kwnc) min(8.7") Supports tip to five PV branches, Fully integrated monitoring using two solid-core CTs,accurate up to±2.5%.Does not MODULES : 46 QCELLS Q.TRON BLK two batterycircuit breakers and Integrated backfeed monitoring M-G2+435 Ambient operating temperature range -40°C to 46°C(-40°F to 115"F) require field wiring. ENPHASE P 9 P 9 One EVSE C1fCUlt breaker. MICROINVERTER : 46 IQBMC-72-M-US Cooling Solar shield,active air cooling Bluetooth-based WI-Fi provisioning Integrated monitoring in the built-in load Fully integrated monitoring using two solid-core CTs,accurate up to±0.5%.Does not for easy Wi-Fi setup. controller require field wiring_. Supports an integrated load Controller with up to 80 A using EV charger monitoring Supports monitoring of EV charger;accuracy up to±2.5%4 double-pole or quadplex breakers. Up to 4=20 A breakers for PV.e - Breakerspaces5 C✓ Rename Up to 1.100 A aggregate PV breaker.' Rev Description Date - 0 INITIAL DESIGN 5(2812025 • Durable NRTL-certified NEMAype t A UPDATED DESIGN s/4/2025 3Renclosure. '10 ACombiner6Cisnotservicee rated.lO Combiner 6C does not support generator lMegatronand fully oN-grWsystems(that is.wHautuNrtysupply). B plug-and-play industd �ra alde ce0 ceUn modem torsystems of up to 96 microinverters • 15- ear limited warranty. 'One unit of CT-200-CLAMP must be purchased separately and Installed on the L2line olthe EV charger.Lead wires of the Cr must be connected to the 10 Gateway according to the instructio In y ty instruction In GIG. PROJECT# NA `Usable as a Rapid Shutdown Initiator If the lO Combiner 6C is installed at a readily accessible outdoor location. °AD breaker spaces are supported with integrated troll-down ki[. DATE DRAWN 6/412025 °Alm supports five 20 A PV branches using three double-pole breakers and one quadplex breaker.Refer to the OIG for information aboutspecific spaces that can be used with the quadplex breakers. 7Shlpswithe factory-installed 60 A breaker.The aggregate PV broakercan beused as a PVdisconnecting moans.lithe to Combiner 6C isinstalled outdoors.tho aggregate PV breaker can be the DRAWN BY E.R Rapid Shutdown initiator. ozozsFrpl,.sa6rr9µmrl�m,eeraedE,ytiasadroa.aacctoaa:.taw,e na+nabamaib6sedm Dstwosasatl-Etrzor-oa-zt ISHFET* PV-7.2 httml/wmFuxic°m/tradwnu4.na°aauNoOnmeratrodamrF dbphtu[,nQy.Inns.,tln US.e,d ode merob.Dat•vbjsa tod,u,an DSH-oos85-3.0 N-zozs-oa-zt TITLE COMBINER SPEC • .. . Compone AAr IRONRIDGE Aire' Flush Mount System Rails Aires Al Rail Aire®A2 Rail Aire®Rail Ties Aire®Dock i •. THESE DRAWINGS ARE SUBJECT TO COPYRIGHT "'-- PROTECTION BY US LAW..REPRODUCTION IN - � ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. ProvidedTwo Optimized The lighter,open AireP The tougher,open Aire®rail Structurally conned and Connects Aires Rails to I Rail Sizes rail for standard conditions. for higher load capacity. bond AireT"°Rails together. attachments with ease. • 6'spanning capability • 8'spanning capability Reinstallable,up to 5x Clicks on,slides easily Current• Wire management tray • Wire management tray • Internal splice design • Drops into open slots Renewables • Mill or anodized black Mill or anodized black • No more splice rules • Anodized assembly Engineering Clamps 8c Grounding cuRREO�meuetBWg2RErsCA0G INC. 3D eS eeL Riverside, 9225 Emil:Projects@mng.solar Websle:w .=ng.co Aire®Lock Mids Aire®Lock Ends Aire®Lock StealHis Aire®Lug PHONE:951 204-5492 CONTRACTORINFO 01 l 2SYSI Securely bond between Securely bond modules to Securely bonds modules to Bonds Aire®Rails to MENT ENERGY LLC. modules to Aires Rails- Aire®Rails along ends. rail ends,entirety hidden. grounding conductors- 7470 so ND AVENUE,MATTITUCK • Fits 30-40mm modules • Fits 30-40mm modules • Angled for easy install Simplified with single bolt HE(63)779 7993 • Utilizes UF02'design • Easy rail engagement • Robust tether leash Low-profile form factor U elnse-ME 52699 • Minimal 1/2 a • Clean aesthetics • Fits most modules Works with 10-6 AWG (MASTER ELECTRICIAN gap L tense-HI-67461 Breathe easy with accelerated installations. (SUFFOLK HOME IMPROVEMENT) Accessories The Aires racking system has been carefully engineered to streamline every part of the installation process. ROCKY BLUFF LLC We've eliminated tiresome hassles,so that you get off the roof and on to your next project faster than ever. Aire®Caps Aire®Clip Ain:®MLPE Mount Aire®All Tile Hook 645 ROSENBURG RD,EAST Aire®retains the strength and reliability that IronRidge installers depend on.It also takes wire management to MARION,NY 11939 the next level with the first(and only)NEC-compliant rail,formally approved and listed as a cable tray. ` AHJ TOWN OF SOUTHOLD UTILITY PSEG LONG ISLAND Strength Tested PE Certified �� PV SUMMARY • SYSTEM SIZE All components have been evaluated ® Pre-stamped engineering letters are Block entry and provide a Keeps wiring contained in Securely bonds MLPE and Attaches rails to tile roofs, (KWDC) STC 435 X 46= 0.010 for superior structural performance. available online for most states. finished look to Aire®Rails. open Aire®Rail channels. accessories to Aire®Rails. with Aire®Dock included. SYSTEM SIZE PTC 404.E IX 146 1= B.609 Stay secure on rail ends._ -_No module_interference _ • Glove-friendly,installation - Works on flat,S,&W tiles (KWAC) : 14.72 @240 Symmetrical,with drain • Simple press-in design Las flush in rail channel Single-socket installation QCELLS Q.5 BLK y P P g y g MODULES 46 QCELLS 35 Class A Fire Rating Approved Cable Tray • Cover rough-cut ends • Slot for easy removal • Low profile form factor Optional deck flashing MICROINVERTER 46 ENASE IQSMPH C-72-M-US Certified to maintain the fire resistance Open channel listed to NEMA VE 1, rating of the existing roof structure. certified to hold PV and DG cables. Resources `��auunu,� - _ Design Assistant .� ot�,s '%. Approved for FL Hurricane Zones ��Fe TM�'Oy'��i UL 2703 Listed System 25-Year Warranty ___—•- _ Quickly go from rough layout ?�*at �T.* Aire®has Florida Product Approval. to fully engineered system. * = Additional details can be found on the Reg Desuiplion Date ® Entire system and components meet Products are guaranteed to arrive Go to IronRidge.conr/design Code website. 0 INITIAL DESIGN 5@e12025 '— =�� safe,.OF Florida Building the latest effective UL 2703 standards. without any impairing defects. �.�,:�����, �a %•4�11111 +� •�\p Learn More at bit.ly/florida-aire A UPDATED DESIGN W4/2025 B PROJECT# NA DATE DRAWN 6/4/2025 0 2023 IronRidge,Inc.All rights reserved.U.S.Patents Pending.Version 1.04 DRAWN BY ER SHEET# PV-7.3 TITLE RAIL SPEC slightlyThe strength of the S-5-1-1 clamp is il design. The patented i setscrews will dimplebut • pierce it— leaving the roof Right �� v� �� - THESE DRAWINGS ARE SUBJECT TO COPYRIGHT ` Ik- The S-S-U and S-5-U Mini damps are each furnished with I (� J PROTECTION BY US LAW.REPRODUCTION IN f 16 ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT the hardware shown to the right.Each box also includes I �� PRIOR WRITTEN APPROVAL FROM CURRENT RightThe , a bit tip for tightening setscrews using an electric screw I located trorr 112-(13.00 mm) RENEWABLES ENGINEERING INC. gun.A structural aluminum attachment clamp,the 5-5-U ge or Pay is compatible wlth most common metal roofing materials I C(jrre(lt excluding copper.All included hardware is stainless Re11@VIl ,�yeS { steeL Please visit wxiw.5-S.com for more information- The S-5-U clamp is by-far our most including CAD details,metallurgical compatibilities and j Engineering I - popular and most versatile clamp. specifications.� CURRENT RENEWABLES ENGINEERING INC. It cits 7 - - - 3600 Lime SUeeLBldg 2 Riverside,CA 92501 about • • E Emil:Projects@creng.solar ' The 5-5-U clamp has been tested for load-to-failure results p _ Websde:v .creng.co profilesseam • on most major brands and profiles of standing seam R PHONE:951}204-5492 ,I and aAmerica---including most structural roofing.,The independent lab test data found at CONTRACTORINFO www.S-5.com can be used for load-critical designs andvertically ° architectural ' • ' • ' ' applications.5-51•holding strength is unmatched in the I r�' clamp •degrees, IndaStry <0 on most horizontal 2 searr profiles' <° 1 ° , Example Prof les Note:Install btRh Its simple design, CzSYS• . mult;ple hole orientationsv,'jhar � - setscrews on same . side o1 clamp. make the S-S-U• clamp so - for• 7470 SOUND AVENUE,MATrITUCK • • •• NEW YORK 11952 such as • • • s well as with • - - PH:(631)779 7993 heavy-dutyapplications., A a Mini S_5_U Mini Clamps License-ME-52669 (MASTER ELECTRICIAN) License- I-67 61 Installation • • _ (SUFFOLK HOME IMPROVEMENn - C specially patented round-point setscrews • the clamp,placing the clamp on - • tightening - (i ,r,: holes centered ROCKY BLUFF LLC >4 OF ,, on part affixr specified tension.Then, 645 ROSENBURG RD,EAST .. providedf r ". MARION,NY 11939 items using the A-d product. Go to www.S-5.com/toois • • • • •• • - • `{ Yh` c E AHJ TOWN OFSOUTHOLD • ••- • • tensioning� I �' I �" clamps. �' �i�s � o N UTILITY PSEG LONG ISLAND • - 1 PV SUMMARY f 0s�s� SYSTEM SIZE ClampS-5-U Mini /10 "� (KWDC) STC 435 X 46= 0.010 _ _ t � PTC 404.6 X 46 = 8.609 • •it • - SYSTEM SIZE -- -- 5 .11 • • _ setscrewrrtertan �13)�!p O- _ (KWAC) 14.72 @240 • • • •• • - •�- - -- ---- - terry- - - -----�� 10 --------- -----' MODULES 46 '-- - 'Sp' M-G2+54$5 RON BLK kinds0 all of •• • • -s:signs, ENPHASE MICROINVERTER 46 108MC-72-M-US disheswalkways,satellite ,antennas, rooftop lighting,lightning protection • is our 11 • ' exhaust stack • popular • ` Please note:All measurements are rounded to bracing, • • condensate s the second decimal plate. clamp,mechanical equipment—just about • •• i of 6 •!- the standing seam profiles 00 5-5YWamingl Please use this product responsiblyl Distributed by - Rev Description Date America. products ate Protethd by rmhlple 115,and foreign patents Visit the wabsae at wwwSS.com!or - in • •� complete Wormatlon on patentsamM trademarks.For maximum holding strength setscrews should 0 INITIAL DESIGN 5/28/2025 be tensioned and re-tensioned"the seam material compresses.tamp setscrew tension should be •o vedhed usinga allbrated torquewnanch between 160and 190 Inch poundswhen used on 23ga steel, A UPDATEDDESIGN 614/2025 and between 130and 150 lndtpoundsforallothermetatsmdthlnnergaugesof steel.ComulttheS-9 •• webslteatw Sscomfor published data regarding holding strength _ B Copynght2L21MetdPadMeradar4ltdS3tpoAmareFesadprotedled - PROJECT# NA S-RaggresslwelYPo hsW-terr46adetrnrLSmdcopyrEJldslNrdonOeT72L DATE DRAWN 6/4/2025 DRAWN BY E.R SHEET# PV-7.4 TITLE ATTACHMENT SPEC