Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
52057-Z
TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 52057 Date: 07/01/2025 Permission is hereby granted to Shiven K Ramji 212 N 9th St Apt PHB Brooklyn, NY 11211 To: install roof-mounted solar panels to existing single-family dwelling as applied for. Premises Located at: 265 Cedar Point Dr E, Southold, NY 11971 SCTM#90.-3-9 Pursuant to application dated 05/29/2025 and approved by the Building Inspector. To expire on 07/01/2027. Contractors: Required Inspections: Fees: SOLAR PANELS $100.00 ELECTRIC -Residential $125.00 -RESIDENTIAL $100.00 Total S325.00 Building Inspector b0�rl �° TOWN OF SOUTHOLD-BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold, NY 11971-0959 ` Telephone (631) 765-1802 Fax (631) 765-9502 htt :// www, 0Lltl10ldtowtn 9� " 1 g Date Received � h APPLICATION FOR BUILDING PERMIT MAY ' 2025 For Office Use Only PERMIT NO._ Building lnspecton G Applications and forms must be filled out in their entirety.Incomplete applications will not be accepted. Where the Applicant is not the owner,an Owner's Authorization form(Page 2)shall be completed. Date: 5/16/2025 OWNER(S)OF PROPERTY: Name: Shiven Ramji SCTM#1000- 090.00-03.00-009.000 Project Address: 265 Cedar Point Drive E, Southold, NY, 11971 Phone#: (646) 575-1333 Email: shiven.ramji@gmail.com Mailing Address: 265 Cedar Point Drive E, Southold, NY, 11971 CONTACT PERSON: Name: Katelyn Tornetta Mailing Address: 2941 Sunrise Hwy, Islip Terrace, NY 11752 Phone#: ( 631) 647-3402 Email: hppermitting@harvestpower..net DESIGN PROFESSIONAL INFORMATION: Name: Michael Dunn, R.A. Mailing Address: 256 Orinoco Dr, Brihtwaters, NY 11718 Phone#: (631) 665-9619 =Eml: Bayblueprint@aol .com CONTRACTOR INFORMATION: Name: Harvest Power LLC Mailing Address: 2941 Sunrise Hwy, Islip Terrace, NY 11752 Phone#: ( 631) 647-3402 Email: hppermitting@harvestpower..net DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ®Alteration ❑Repair ❑Demolition Estimated Cost of Project: ❑Other $ 64,230.00 Will the lot be re-graded? ❑Yes ®No Will excess fill be removed from premises? ❑Yes ❑No 1 PROPERTY INFORMATION Existing use of property: Residence Intended use of property: (no change) Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes ®No IF YES, PROVIDE A COPY. ® Check Box After Reading: The owner/contractor/design professional Is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the Issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print name): Authorized Agent ❑Owner Signature of Applican Date: 5 I)6/Z STATE OF NEW YORK) SS: COUNTY OF Suffolk ) Katel n Tornetta being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Agent - Harvest Power LLC (Contractor, Agent, Corporate off irer,etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this day of / t 6LS ,20 Nota a li MICHAEL CAUSE Notary Public-State of New York NO,Of CA0035256 AUTHORIZATIONPROPERTY OWNER Qualified In Suffolk County ..� ...�._ �__....0 _ h f t "e appifcarit is r dt t �dvvrr r .�. y-C=,MI, rn.Fplr",Mar 2 ,... 29. w. I, Shiven Ram'i residing at 265 Cedar Point Drive E, Southold, NY, 11971 do hereby authorize Katel n Tornetta to apply on my behalf tote own of Southold Building Department for approval as described herein.. 5/16/2025 Owner's 5 n , ure Date Shiven Ram'i Print Owner's Name 2 BUILDING DEPARTMENT- Electrical Inspector � TOWN OF SOUTHOLD p Town Hall Annex- 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 � a 0P amesh southoldtownn . ov-� seand southoldtownn ov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 5/21/2025 Company Name: Harvest Power LLC Electrician's Name: Carlo Lanza License No.: ME-68518 Elec. email:hppermitting@harvestpower.net Elec. Phone No: (631) 647-3402 El I request an email copy of Certificate of Compliance Elec. Address.: 2941 Sunrise Highway, Islip Terrace, NY 11752 JOB SITE INFORMATION (All Information Required) Name: Shiven Ramji Address: 265 Cedar Point Drive East Cross Street: Phone No.: 646-575-1333 BIdg.Permit#: Gj ) email:shiven.ramji@gmail.com Tax Map District: 1000 Section:090.00 Block: 03.00 Lot:009.000 BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly):. Installation of a 14.72 kW Solar PV system with (32) REC460AA Pure-RX Roof mounted panels. Square Footage: Circle All That Apply: Is job ready for inspection?: YES [; NO R]Rough In Final Do you need a Temp Certificate?: `/ YES [] NO Issued On Temp Information: (All information required) Service Size 1 Ph E]3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead #Underground Laterals 1 2 H Frame Pole Work done on Service? LJ Y ON Additional Information: PAYMENT DUE WITH APPLICATION l ttilding Department Application AUTHORIZATION (Where the Applicant is not the Owner) 1, Shiven Ramii Ye .. ,.._.. _ residing at 265 CedarPoint Drive E, (Print property owner's name) (Mailing Address) Southold,NY, 11971 do hereby authorize Kat I n Tornetta a ... .�.._......._� (Agent) Harvest Power LLC to apply on my behalf to the Southold Building Department. 5/16/2025 i.f`lwncr*s ignatll'Hb (Date) Shiven Ramj (ht"�nt Owner's Alt'11t4') _,.. _._ . CONSENT TO INSPECTION Shiven Ramii ,the undersigned, do(es) hereby state: Owner(s)Name(s) That the undersigned (is)(are)the owner(s)of the premises in the Town of Southold, located at 265 Cedar Point �rly ,E, Southold, NY 11971 which is shown and designated on the Suffolk County Tax Map as District 1000, .._. Section 090.00 , Block 03.00 , Lot 009.000 That the undersigned(has)(have) filed, or cause to be filed,an application in the Southold Town Building Inspector's Office for the following. Installation of a 17.72 kW Solar PV s stein with 32 _REC460AA Pure-RX Roof mounte"anels.v w...._ . _ .._._ .........w� That the undersigned do(es) hereby give consent to the Building Inspectors of the Town of Southold to enter upon the above described property, including any and all buildings located thereon,to conduct such inspections as they may deem necessary with respect to the aforesaid application, including inspections to determine that said premises comply with all of the laws,ordinances, rules and regulations of the Town of Southold. The undersigned, in consenting to such inspections;do(es) so with the knowledge and understanding that any information obtained in the conduct of such inspections may be used in subsequent prosecutions for violations of the laws, ordinances, rules or regulations of the Town of Southold. My Dated: 5/16/2025 (Sign ur, Shiven Rani.. r (Print Name) .�_............� (Signature)��...._..._... (Print Name) S� S Graham Consulting Corp. 256 Orinoco Drive,Suite A Brightwaters,NY 11718 Planning& Design (631)665-9619 May 21, 2025 Town of Southold Building Department 54375 Rt. 25 Southold, NY 11971 Re: Shiven Ramji Residence 265 Cedar Point Drive E. Southold, NY Proposed 14.72 kWDC, 12.16 kWAC PV System To Whom It May Concern, Please be advised that I have analyzed the existing roof structure at the above-mentioned premises and have determined that it is adequate to support the additional load of the solar panels and a 140 mph wind load and 20 psf snow load without overstress, in accordance with the following: The 2020 New York State Uniform Fire Prevention and Residential Building Code; Town of Southold Local Code, Long Island Unified Solar Permit Initiative, (LIUSPI); and 2020 National Electric Code NFPA 70/2020 National Electric Code including ASCE7-16 If you have any further questions, do not hesitate to call. S cgrelly lei h'ael.. ::Du1%,aRA t' Rzf ":Z PHOTOVOLTAIC ROOF MOUNT SYSTEM 32 MODULES-ROOF MOUNTED - 14.72 kWDC, 12. 16 kWAC I P 265 CEDAR POINT DR E, SOUTHOLD, NY 11971 , USA HARVESTPOWER HARVEST POWER LLC — ----- - - 2941 SUNRISE HIGHWAY ISLIP SYSTEM SUMMARY: TERRACE,NY 11752 SHEET INDEX TEL:(801)98"585 (N)32-REC SOLAR REC460AA PURE-RX(460W) MODULES GOVERNING CODES: PCtGHJT site:www.narvest owernet (N)32-ENPHASE ENERGY IQ8X-80-M-US MICRO-INVERTERS 2017 NATIONAL ELECTRICAL CODE PV-0 COVER SHEET Q �. (N)JUNCTION BOX 2020 NEW YORK STATE UNIFORM CODE PV-1 SITE PLAN WITH ROOF PLAN e�,1` D ���" � \ (E)225A MAIN SERVICE PANEL WITH (E)200A MAIN BREAKER 2020 NEW YORK STATE RESIDENTIAL CODE PV-2 ATTACHMENT DETAILS T<1 /Ico i (E)200A AUTOMATIC TRANSFER SWITCH WITH (E)200A MAIN BREAKER PV-3 THREE LINE DIAGRAM r (N) 100A FUSED AC DISCONNECT PV-4 PLACARDS&WARNING LA (N) ENPHASE IQ COMBINER BOX PV-5 ADDITIONAL NOTES �" �Q PV-6+ SPEC SHEETS DESIGN CRITERIA: VERSION ROOF TYPE:-ASPHALT SHINGLE NUMBER OF LAYERS: -1 DESCRIPTION DATE REV. ROOF CONDITION: OK BLDG.PERMIT 05-20-2025 0 ROOF FRAME: -2"X8" RAFTERS @16"O.C. STORY:-TWO STORY SNOW LOAD : -25 PSF WIND SPEED :- 130 MPH WIND EXPOSURE:- D GENERAL NOTES: 1. INSTALLATION IN ACCORDANCE WITH MANUFACTURER • RECOMMENDATIONS. 2. ENGINEER TO INSPECT PROJECT AFTER INSTALLATION ARRAY LOCATIONS AND CERTIFY COMPLIANCE. , I PROJECT SITE 3. PROJECT TO BE INSTALLED WITH CODE COMPLIANT i RACKING INSTRUCTIONS FOR UNI-RAC SOLAR MOUNT PROJECT NAME SYSTEM. \ 4. FOLLOW BALLASTING SCHEDULE ON ROOF PLAN. `�; ♦ ` j„ r 5. HARVEST POWER, LLC., THE SOLAR INSTALLATION CONTRACTOR, COMPLIES WITH ALL LICENSING&ALL (a Op 0 RELATED REQUIREMENTS OF THE GOVERNING �_ ~�+ LLJ :D � 0 MUNICIPALITIES AND THE LOCAL ELECTRIC UTILITY ar d :; t r:. C) O = AHJ'S. "+► — ti O F- 6. THIS PROJECT WILL COMPLY WITH THE CURRENT NEC Z 0-) p a O REQUIREMENTS INCLUDING ARTICLE 690 SOLAR . '� Q O J 0 PHOTOVOLTAIC PV SYSTEMS. z 0 Z O O 7. THE ROOF WILL HAVE NO MORE THAN A SINGLE LAYER . 0- O >_ O OF ROOF COVERING IN ADDITION TO THE SOLARLU EQUIPMENT. 265 Cedar Point Dr E, > Q 0 O East J Z 8. INSTALLATION WILL BE FLUSH-MOUNTED, PARALLEL Southold, NY 11971, Hampton = � 0 C) TO AND NO MORE THAN 6.5"ABOVE ROOF Lo = O 0 United States 9. MAINTAIN A MINIMUM OF 18"CLEARANCE AT RIDGE 4 ' 9 F- AND AT ONE GABLE EAVE. �r North Sea N Z Q = 10. THIS DESIGN COMPLIES WITH 130 MPH WIND » .r r Riverhead 0 Q Q REQUIREMENTS OF THE RESIDENTIAL CODE OF N.Y.S M M . AND ASCE 7-16. 11. WHEREVER THE ROOF PLAN DOES NOT COMPLY WITH 27 Alan He . SHEET NAME ACCESS AND VENTILATION REQUIREMENTS OF THE East UNIFORM CODE, HARVEST POWER PROPOSES THAT ?' Quogue COVER SHEET ALTERNATIVE VENTILATION METHODS WILL BE ' EMPLOYED. REVIEW AND APPROVAL SHALL BE AT THE DISCRETION OF THE MUNICIPALITY IN WHICH THIS k_ SHEET SIZE DOCUMENT HAS BEEN FILED. , ��' 7 ANSI B 12. THE DESIGN PLANS COMPLY WITH THE 2020 NEW YORK STATE UNIFORM FIRE PREVENTION AND 11" X 17" RESIDENTIAL BUILDING CODE. 1 AERIAL PHOTO 2 VICINITY MAP SHEET NUMBER PV-0 SCALE:NTS PV-0 SCALE: NTS PV-O MIDOULE TYPE, DIMENSIONS & WEIGHT ROOF ACCESS AREA: NUMBER OF MODULES=32 MODULES SHALL BE LOCATED IN AREAS THAT DO NOT REQUIRE THE MODULE TYPE=REC SOLAR REC460AA PURE-RX(460W)MODULES _ (E) SEA ZONE PLACEMENT OF GROUND OVER OPENINGS SUCH AS WINDOWS fp MODULE WEIGHT=51.58 LBS/23.4 KG. OR DOORS,AND LOCATED AT STRONG POINTS OF BUILDING MODULE DIMENSIONS= 68.03"X 47.44"=22.41 SF LANE CONSTRUCTION IN LOCATIONS WHERE THE ACCESS POINT UNIT WEIGHT OF ARRAY=2.30 PSF ppER�� LU DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH (E)TREE (TYP.) A. AS TREE LIMBS,WIRES OR SIGNS. HARVESTPOWER HARVEST POWER LLC (� 2941 SUNRISE HIGHWAY ISLIP / �/" TERRACE,NY 11752 (E) FENCE C(C� -� L ICI /jF�, L:(8(1)9893585 v J 0- �� ZYeesite. harvestoower.net (E) DETACHED STRUCTURE IK0✓�s (E) CHIMNEY (N) ENPHASE IQ COMBINER BOX �� L(< ) <`<'�C.,. ) (� VERSION r^ / L 1. `�,�,`�/�`'' �(C �-'Jl DESCRIPTION DATE REV. (N) 100A FUSED AC DISCONNECT ------ cVVJ� � -/ J I BLDG.PERMIT os zo-zozs o (E)200A AUTOMATIC TRANSFER SWITCH WITH (E)200A MAIN BREAKER (E) UTILITY METER i !�� �„ C. �:" "_� 05 i 00 (E)225A MAIN SERVICE PANEL WITH (E)200A MAIN BREAKER (INSIDE) --- =<v PROJECT NAME o o w Cl � CD �,"<(�^ F1'q y �; Trip ��<<< , _ ) �) O oST { o pI— p` % ,- • • . y.Cis Ry F- rn o Q >. (N) 1"PVC CONDUIT RTy<%� // • • • J • • _.'l"y0 Z o a O RUN 7/8"ABOVE ROOF NF `�/ i' ,;� • • • • • �� „ } o (N)JUNCTION BOX W rn �e • • �C_l-, ROOF#3 = W O o ~ �. (04) REC460AA PURE-RX (460W) co (-) = o OO �( ^� tom,�; RAFTERS=2 X8 @16 O.0 Lo ROOF#1 f i 25'AZIMUTH,27'TILT N O 2 (12) REC460AA PURE-RX(460W) �� �'l ) Q RAFTERS=2"X8"@16"O.0 ` ����� C,Civ Q 205°AZIMUTH,28'TILT 7s( (` �� y�4; ' ROOF#2 (16) REC460AA PURE-RX(460W) •�� t`;�\ (� "�,11 RAFTERS=2"X8"@16"O.0 SHEET NAME (32) ENPHASE ENERGY IQ8X-80-M-US MICRO-INVERTERS CL �� t�3 205'AZIMUTH,270 TILT SITE PLAN WITH ROOF PLAN J SHEET SIZE ANSI B �J O (E) GATE(TYP.) I V X 17" SITE PLAN WITH ROOF PLAN ^ ANT SHEET NUMBER ' O PV-1 a � � a ' •J � A PV MODULES HARVESTPOWER HARVEST POWER LLC 2941 SUNRISE HIGHWAY ISLIP TERRACE,NY 11752 C TEL:(801)989-3585 SEE ENLARGED VIEW D(� .i •web :www.harvest owecnet @ 6 co Lu l C (E) ASPHALT SHINGLE ROOF E�2`�� `10. NY J= GENERAL NOTES: VERSION 1. RAILS TO BE INSTALLED TWO PER PANELS AS SHOWN IN DETAIL. DESCRIPTION DATE REV. 2. ALL PENETRATIONS TO BE MADE@ 48"O.C. BLDG.PERMIT 05-20-2025 0 3. BOLTS TOBE INSTALLED INTO RAFTERS. 4. MINIMUM 2.5"PENETRATION INTO WOOD FOR CODE COMPLIANCE. 1 ATTACHMENT DETAIL NOTE:- "ACTUAL ROOF CONDITIONS AND RAFTERS(OR SEAM) LOCATIONS MAY SCALE: NTS VARY. INSTALL PER MANUFACTURER(S)INSTALLATION GUIDELINES AND ENGINEERED SPANS FOR ATTACHMENTS." END/ MID CLAMP PV MODULES PROJECT NAME 00 Q O 0 Lu J C) O � I- rn oQZ) L-FOOT Z C) 0- O r O J (n Z Z C) } O t (E)ASPHALT SHINGLE ROOF w rn F- > Qclo -► Z (N) UNIRAC 0 ROOF/ DECK MEMBRANE _ Lu O o SM STANDARD RAIL cq U o O _ 1-- / { N O aa- _ Q Q (E) 2"X8" RAFTERS @ 16" O.0 2.5" MIN. EMBEDMENT SHEET NAME ATTACHMENT FLASH KIT PRO FLASHING DETAIL SHEET SIZE BUILDING STRUCTURE ANSI B 5/16" STAINLESS STEEL LAG BOLT 11" X 17" WITH SS EPDM BONDED WASHER, ATTACHMENT DETAIL (ENLARGE VIEW) 2-1/2" MIN. EMBEDMENT. SHEET NUMBER 2 SCALE: NTS PV-2 A (32) REG2 SOLAR REC460AA PURE-RX(460W) MODULES BILL OF MATERIALS (32) ENPHASE ENERGY IQ8X-80-M-US MICRO-INVERTERS EQUIPMENT QTY DESCRIPTION (04) BRANCHES OF 08 MODULES CONNECTED IN PARALLEL PER BRANCH SOLAR PV MODULE 32 REC SOLAR REC460AA PURE-RX(460W)MODULES MICRO-INVERTER 32 ENPHASE ENERGY IQ8X-80-M-US MICRO-INVERTERS COMBINER BOX 1 ENPHASE IQ COMBINER BOX SYSTEM SIZE:-32 x 460W= 14.72 kWDC JUNCTION BOX 1 600V,55A MAX,4 INPUTS,MOUNTED ON ROOF FOR WIRE&CONDUIT TRANSITION HARVESTPOWER 32 X 380VA= 12.16 kWAC HARVEST POWER LLC 2941 SUNRISE HIGHWAY ISLIP AC DISCONNECT 1 AC DISCONNECT 100A FUSED,VISIBLE LOCKABLE LABELED,70A FUS 4�00�/(a> � TERRACE,NY 11752 Q C� TEL:(801)989-3585 DO Jwe ite:www.harve�t LU k J3 r.' TO UTILITY GRID PdY C ;vJ 08 MICRO-INVERTERS IN BRANCH CIRCUIT#1 STl�j: (fir L1 L2 N VERSION -_-i - - DESCRIPTION DATE REV. BI-DIRECTIONAL UTILITY METER BLDG.PERMIT 05-20-2025 0 I = I = I L 1-PHASE,3-W, ti 1 ti I ti I I 120V/240V,60Hz L__------ ---- (N)ENPHASE LINE SIDE TAP 08 MICRO-INVERTERS IN BRANCH CIRCUIT#2 I COMBINER BOX I TIC ... - _. _._._ i (E)20DAAUT MA IQ TRANSFER SWITCH WITH - -- - -' - - --- GATEWAY 200AK (E)200A MAIN BREAKER = i � (E)GENERATOR UNIT (E)MAIN BREAKER �______~� ---------- ��j-_-______i (N)AC DISCONNECT 100A ^ 200A/2P,240V I (N)JUNCTION BOX FUSED,VISIBLE LOCKABLE V 08 MICRO-INVERTERS IN BRANCH CIRCUIT#3 j 15A LABELED,70A FUSES, 1 240 VAC - --- .......... . 1_. 20A._ u u —— — PROJECT NAME .._............. r- - 20A 70A FUSES I 1 � � � � I u L L1 L1 I I Q O ❑ �'------ `—J---------- `--I--------- i 2oA L2 L2 I ^ I W (n O J I I L Lt Fr__ 20A N N I r- G -- ----------------I I (E)225A MAIN ❑ p I=- 08 MICRO-INVERTERS IN BRANCH CIRCUIT#4 i 1 I SERVICE PANEL O O Q WITH(E)200A MAIN Z (C a O BREAKER r-. - i_ •.• - I u u ^ I (BOTTOM FED) } O J LL .........._ ......- - ' _ I N j (3)#4 BLK RED WHT THHN (2)#4 BLK RED THHN 200A(� I W Z � I— ,� i i ti I i (1)#6 THHN STRANDED (1)#6 WHT THHN I > Q ❑ O J Z ____ 1------- G -- l N I GREEN GROUND IN 1"PVC (1)#6 THHN STRANDED — J O - ----- ---------- �--�=- -r --- - �-- ----- -- -- I CONDUIT RUN GREEN GROUND IN 1"PVC :..................--- � W O O O CONDUIT RUN a (.) = r Z) Lo (32)ENPHASE ENERGY IQ8X-80-M-US (4)Q CABLE EXISTING �I (�J O Z _ (1)#6 BARE CU GND � MICROINVERTERS GROUNDING (n Q (8)10 AWG THWN-2 SYSTEM Q TERMINATOR CAP ON LAST CABLE (1)#6 THHN STRANDED CONNECTOR Q-CABLE(TYP) GREEN GROUND IN 1"PVC CONDUIT SHEET NAME THREE LINE DIAGRAM SHEET SIZE ANSI B 11" X 17" 1 THREE LINE DIAGRAM SHEET NUMBER SCALE: NTS PV_3 • 4" y 1 r ELECTRICAL SHOCK HAZARD PHOTOVOLTAIC SYSTEM �7©L!�► - V STE Q P P E D COMBINER PANEL TERMINALS ON LINE AND LOAD DO NOT ADD LOADS NTH F hID SI"IU ©O HARVESTPOWER SIDES MAY BE ENERGIZED IN HARVEST POWER LLC THE OPEN POSITION LABEL LOCATION: 941 SUNRISE HIGHWAY(SLIP PHOTOVOLTAIC AC COMBINER(IF pRCH/ TERRACE,NY 11752 APPLICABLE). � Cn TEL:(801)989-3585 LABEL LOCATION: `C!i �; (�, ��vebs :www.harvest owernet INVERTER(S),AC DISCONNECT(S),AC 3 TURN RAPID SHUTDOWN ; COMBINER PANEL(IF APPLICABLE). SWITCH TO THE"OFF" so ��6cTP,e 'a, PV PA LLS u.j POSITION TO SHUT DOWN - PV SYSTEM AND REDUCE . 'y ' SHOCK HAZARD IN THE `` �� : ARRAY. N S4 J VERSION FOR • , ■ PV SYSTEMNIDESCRIPTION DATE REV. LABEL LOCATION: BLDG.PERMIT 05-20-2025 0 ON OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE LABEL LOCATION: DISCONNECTING MEANS TO WHICH THE PV SYSTEMS UTILITY SERVICE ENTRANCE/METER,INVERTER/DC ARE CONNECTED.. DISCONNECT IF REQUIRED BY LOCAL AHJ,OR OTHER LOCATIONS AS REQUIRED BY LOCAL AHJ. POWER SOURCE OUTPUT CONNECTION DO NOT RELOCATE THIS PROJECT NAME OVERCURRENT DEVICE LABEL LOCATION: ADJACENT TO PV BREAKER AND ESS Q O OCPD(IF APPLICABLE). W O J BUILDING SUPPLIED BY UTILITY _ o 0 0 GRID AND PHOTOVOLTAIC o Q SYSTEM o o a o W Lug m - POWER SOURCE . ■ w- > Q 0 CDJ Z LABEL LOCATION: Z U) V O O INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, O T— F— AT EACH TURN,ABOVE AND BELOW PENETRATIONS, It ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. w N 0 Z 2 0 � Q Q W U PHOTOVOLTAIC • N SHEET NAME MAXIMUM •- .AMPS PLACARD & NOMINALOPERATING AC VOLTAGE: lk WARNING LABELS LABEL LOCATION: (N)COMBINER BOX (N)PV ARRAY SHEET SIZE AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF ANSI B (N)AC DISCONNECT (E)MAIN SERVICE PANEL(INSIDE) INTERCONNECTION. n (E)AUTOMATIC TRANSFER SWITCH (E)UTILITY METER 11„ X 17 LABEL LOCATION: SHEET NUMBER POINT OF INTERCONNECTION (PER CODE:NEC690.56(B),NEC705.10,225.37,230.2(E)) PV-" 1. EACH MODULE TO BE GROUNDED USING THE SUPPLIED CONNECTION POINT PER MANUFACTURER'S REQUIREMENTS. ALL SOLAR MODULES, EQUIPMENT, AND METALLIC COMPONENTS ARE TO BE BONDED. IF THE EXISTING-GROUNDING I p ELECTRODE SYSTEM CAN NOT BE VERIFIED OR IS ONLY METALLIC WATER PIPING, HARVESTPOWER IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSTALL A SUPPLEMENTAL ARVEST POWER LLC GROUNDING ELECTRODE. .,�i�� UNRISEHIGHWAYISLIP � � RACE,NY-11752 t�:;�y ,ite (8 iary st ower.net 2. ALL PLAQUES AND SIGNAGE REQUIRED BY THE LATEST EDITION OF NATIONAL �P. . ELECTRICAL CODE. LABEL SHALL BE METALLIC OR PLASTIC, ENGRAVED OR w •I MACHINE PRINTED IN-A CONTRASTING COLOR TO THE PLAQUE:-PLAQUE SHALLrz��BE UV RESISTANT IF EXPOSED TO SUNLIGHT. `' " 7 3. AC CONDUCTORS SHALL BE RUN IN EMT AND SHALL BE LABELED, CAUTION AC . CIRCUIT" OR EQUIV. EVERY 5 FT. VERSION DESCRIPTION DATE REV. 4. EXPOSED NON-CURRENT CARRYING METAL PARTS OF ELECTRICAL EQUIPMENT BLDG.PERMIT 05-20-2025 0 SHALL BE GROUNDED IN ACCORDANCE WITH 250.134 OR.250.136(A). 5. CONFIRM LINE SIDE VOLTAGE AT ELECTRIC UTILITY SERVICE PRIOR TO CONNECTING INVERTER. VERIFY SERVICE VOLTAGE IS WITHIN INVERTER VOLTAGE OPERATIONAL RANGE. , 6. OUTDOOR EQUIPMENT SHALL BE NEMA-3R RATED'OR BETTER. 7. ELECTRICAL CONTRACTOR TO PROVIDE CONDUIT EXPANSION JOINTS AND PROJECT NAME ANCHOR CONDUIT RUNS AS REQUIRED PER NEC. 8. ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL w U) o 0 MEANS DESIGNED AND LISTED FOR SUCH USE,-AND FOR ROOF-MOUNTED SYSTEMS, WIRING MUST BE PERMANENTLY AND COMPLETELY HELP OFF OF THE ti o Oz 0 ROOF SURFACE. NEC 110.2 - 110.4 / 300.4 z °' � a. O - go `- o a__j U) }- o 9. ALL ROOF PENETRATIONS MUST BE FLASHED. SIMPLY CAULKING DOES NOT z w z c } O SUFFICE. j o 0 0 z � w0o5o LO N O z 2 (n Q Q SHEET NAME ADDITIONAL NOTES SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-5 ° �4Y SOLAR`S MOST TRUSTED REC C C .. HARVESTPOWER HARVEST POWER LLC i yq` = ° GENER'ALQATA '-- - '�arass - 2941HIGHWAY TERRA E,NY 17 2 LIP I ytw Cellt e: 88ha1f-cutRECbifaciaLheterojunctioncells �` TEL:(801)969 35g5 1S 1 E# (4 yP with lead-free,gapless technology CND, ebsite:www.harvest ower.net f +rf " 3.2mmsolarglasswithanti-reflective surface treatment � A Glass: In accordance with EN 12150 8atksheet: Highly resistant polymer t 3 tL - r Frame: Anodized aluminum black + ° �.. 4-part -free REE ALPHA ,unctionbox: a "'x IP68 rated,in accordancewithlEC62790 StaubliMC4PV KBT4/KST4(4mm2) 1' Connectors: i in accordance with lEC 62852,IP68 onlywhen connected : I' `,,� 4mm2solarcable 17+1.7m nl� ii f1 r 4 PURE-RXCable: °m'SERIES aFl in accordancewith EN 50618 s - l � _ ) Dimensions: 1728x1Z05x30mm(2.OBm') ' i C1 VERSION . ; ;.' ' --+s 22s � "`r � DESCRIPTION DATE REV. Weight: 23.4 kg "l z•: .y t BLDG.PERMIT 05-20-2025 0 PRODUCT SPECIFICATIONS Origin: Made`nSingapore ;�,•, Measurements inmm EL CTRj AL f)ATA Pr°dutt @ode:.REExxxAA Pure-ftX CERTIFICATIOW ` IEC 61215:2021,IEC 61730:2016,UL 61730 {, I Power Output-P.,�(Wp) 450 460 470 - Watt Class Sorting-(W) 0/+10 0/+10 0/.10 IEC62804 PID IEC61701 Salt Mist Nominal Power Voltage-VMPe(V) 54.3 54.9 55.4 IEC62716 Ammonia Resistance v Nominal Power Current-I.e(A) 8.29 8.38 8.49 ISOII925-2 Ignitability(EN13501-1 Class E) to Open Circuit Voltage-Voc(V) 65.1 65.3 65.6 IEC62782 Dynamic Mechanical Load Short Circuit Current-Is,(A) 8.81 8.88 895 IEC61215-2:2016 Hallstone(35mm) IEC62321 Lead-freeacc.to RoHS EU 863/2015 Power Density(W/m2) 216 221 226 IEC61730-2:2016 Fire Class C(as per UL790) PanelEfficlency(%) 21.6 22.1 22.6 ISO 140 01.15 0 90 01.IEC 45001,IEC 62941 rC - take8.vay Power Output-P�,.(Wp) 343 350 358 ` ` � '' 1A,_q'wtre<vurc Le 'eB r ,dn d- PROJECT NAME NominalPowerVoltage-V.p(V) 51.2 51.7 S2.2 e C) Nominal Power Current-1,,(A) 6.70 6.77 6.86 cndk�cm�umr ®eClaYe: Z Open Circuit Voltage-Voc(V) 61.3 61.6 61.8 t Q O Q TEMPERATURE Et N INGS` 3 Short Circuit Current-Isc(A) 7.11 7.17 7.23 W (� J Values at standard test conditions(STC:air mass AM 75,Irradiance 1000 W/m2,temperature 25°C),based on a production spread with a Nominal Module OperatingTemperature: 44°C(±2°C) 0� O t tolerance of P,,,�,Voc&Is,t3%within one watt class.Nominal module operatingtemperature(NMOT:air mass AM 15,Irradiance 800 W/m', o Ll. COMPACT + PANEL P /), P (.) Tem erature coefficientofP -0.24%/°C 00 temperature 20°C,winds peed m/s).*Where xzx indicates the power class P at STC above. P ea+x' Q r + 4, MAXIMIJ R T1',GS ARRANT TemperaturecoeffidientofVoc: 0.24%/°C CT) CDQ Temperature coefficient oflsc: 0.04%/1C O Operationaltemperature: -40...+85°C Standard RECProTrust - Z m a temperature coefficients stated are iinearvalues r' CD -1 ffi U) A. „ CURRENT Maximum system voltage: 1000V InstalledbyanREC No Yes Yes - O } O LL 2 Certified5°IarProfessional aELIVERI 1N ORMATI(1tJ O >_ Maximum testload(front): +7000Pa(713kg/m) Z Z COMPATIBLE P+ B P System Size All r25 kW 2S-500 kW Panels er allet: 33 � CD I__ O M aximu m test load(rear): -4000Pa(407kg/m2y Product Warranty rs 20 25 25 P P - m W O ty(Y ) Panels per40ftGP/high cube container. 594(18pallets) _ > Q Q O --I Z g Max series fuse rating: 25A Power Warranty(yrs) 25 25 25 Z. Q _) O Panelsper13.6mtruck: 660(20pallets) tq 0 Max reverse current: 25A Lab or Warranty(yrs) 0 25 10 a LL( Q O O .•oe SeeInstallation manual for mountl instructions. Power inYearl 98% 96% 98% �o 1 Design load 7.5ngsafe� factor) -- LOW LIGHTBEHRViOIJR g / (safety Annual Degradation 0.25% 0.25% 0.25% r Typical low irradiance performance of module at STC: 1h CO Power inYear2S 92% 92% 92% o 25 YEAR a CV The REC ProTrust Warrantyls onlgavailable onpanelspurchased a° a throughanRECCertifiedSolarPmfessionalinstaller.Warranty "'-'""-"-"`""- - •� a conditions apply.Seewwwxecgrwp.comfor more details. w Available from: m n _ SHEET NAME . '■ ■ Irradiance(W/m') SPEC SHEET 6. cw � +� s • SHEET SIZE ` ANSI B RECSolarPTE.LTD. Founded in1996,REC Group isaninternational pioneering dedicated to empowering con sumers 20TuasSouthAve.14 _ 1 n X/ -7" P y ® ��� 1 /� 1 with clean,affordable solar power.As Solar's Most Trusted,REC is committed to high quality,innovation,and a low carbon footprint in the solar materials and solar panels it manufactures.Headquartered in Norway with operational Singapore637312 e` headquarters in Singapore,REC also has regional hubs In North America.Europe,and Asia-Pacific. post@recgroup.com www.recgroup.com SHEET NUMBER PV-6 1 SOLARMOUNT ::� U N I RAC BETTER DESIGNS TRUST THE INDUSTRY'S BEST DESIGN TOOL CONCEALED UNIVERSAL o 1 I o•1 1 Start the design process for every project in our U-Builder on-line design tool, ENDCLAMPS It's a great way to save time and money. I ' ' BETTER SYSTEMS VERSION ONE SYSTEM-MANY APPLICATIONS Quickly set modules flush to the roof on steep pitched roofs.Orient a large variety D . . . 0 of modules in Portrait or Landscape.Till the system up on flat or low slow roofs. END CAPS INCLUDED Components available in mill,clear,and dark finishes to optimize your design financials WITH EVERY ENDCLAMP == and aesthetics. BETTER RESULTS MAXIMIZE PROFITABILITY ON EVERY JOB CONCEALED Trust Unirac to help you minimize both system and labor costs train Ilia time the job is UNIVERSAL quoted to the time your teainsgot off the roof.Faster installs..Less Waste.More Profits. CLAMPS UNIVERSAL SELF r•."•UNIRAC BETTER SUPPORT STANDING MIDCLAMPS 25 WORK WITH THE INDUSTRIES MOST EXPERIENCED TEAM Professional support for professional installers and designers.You have access to — - - — ._• YEAR our technical support and training groups.Whatever your support needs,we've got t OPTIONAL you covered.Visit Unirac.com/solarmount for more information. TRIM WA ` ! � RRAlIfY CD TOOL SAVES TIME&MONEY - • BOIJDING&GROUNDING . g . •=�� . - Visit desi numrac.com •MaiUL2703 -MECHANICAL LOADING _ -, •SYSTEM FIRE - • • • CD0 l UNIRAC CUSTOMER SERVICE MEANS THE HIGHEST LEVEL OF PRODUCT SUPPORT • \ • • • • + Fki WillI F UNMATCHED CERTIFIED ENGINEERING BANKABLE DESIGN PERMIT • • l i 'l l + 11911I 1 11. 1 I I •I I I i i t i l EXPERIENCE QUALITY EXCELLENCE WARRANTY TOOLS DOCUMENTATION • TECHNICAL SUPPORT CERTIFIED QUALITY PROVIDER BANKABLE WARRANTY Unirac's technical support team is dedicated to answering Uniracis the only PV mounting vendorwithISO Don't leave your project to chance.Unirac has the questions&addressing issues in real time.Anonline certifications for 9001:2008,14001:2004 and OHSAS financial strengthto back our productsand reduceyourrisk. SHEET NAME THE PROFESSIONALS' CHOICE FOR RESIDENTIAL RACKING stamped eocusondsechni aldatasheetgreports, 180il,for ,andfhmeansweselwerthehionsdemohest nstrt Have peace ofmin.SOLARMOUN are proveredhproducts a25yot siampedleilersandterhniraldalasheeisgreatly farfif,form,and func lion-Tltesecertiticationsdemonstrate exceptional quality.SOLARMOUNTiscoveredtiya25year S.PEC SHEET simplifies your perrnittingand project planning process. our excellence and commitment to first class business practices. limited produclwarranly and a5yearlintited finish warranty. IlllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllilllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllSHEET SIZE BEST INSTALLATION EXPERIENCE*CURB APPEAL-COMPLETE SOLLITION•UNIRAC SUPPORT ENHANCE YOUR REPUTATION WITH QUALITY RACKING SOLUTIONS BACKED BY ENGINEERING EXCELLENCE AND A SUPERIOR SUPPLY CHAINANSI B FOR QUESTIONS 0R CUSTOMER SERVICE VISIT UNIRA0.00M 0R CALL (505) 248-2702 r;;-•i;vAiNFR1,Tf.1wD IF FOR QUESTIONS OR CUSTOMER SERVICE VISIT UNIRAC.COM OR CALL (505) 248-2702 Unirac State Letter-NY Tectonic Tectonic Tectonic WOs 12,2024 FP August 12,2024 D PRACTICAL SOLUTIONS.EXCEPTIONAL SERVICE. PAACTICALSOLUTIONS,CCCCPTIONAL SCINNCC, HAC Q\VEST■ OWER HARVEST POWER LLC 2941 SUNRISE HIGHWAY ISLIP August 12, 2024 ■ Metal Roof: Standing Seam Attachments, PM-9000s, and PM Adjust Slotted TERRACE,NY11752 ■ Tile Roof: Solar hooks, Flashkit Tile Replacement (TR) TEL:(801)989-3585 f CIS bs .harvest owecnet Unirac Attn: Engineering Services Department The U-Builder Tool should be used under the responsible charge of a registered '�� �_ -Dv. 1411 Broadway Boulevard NE professional engineer required by the authority having jurisdiction. The design to Albuquerque, NM -87102-1545 and Unirac do not evaluate the existing roof structure, or the PV panels themselve .w 02 TEL: (505) 242-6411 See the construction and installation drawings and manuals for addition I jl information provided by Unirac. RE: ENGINEERING CERTIFICATION LETTER FOR THE UNIRAC SOLARMOUNT (SM) ROOF PV PANEL SUPPORT SYSTEM Sincerely, STATE: NEW YORK OF NE(�,yF. • VERSION Tectonic ,r\P �° A. 0& 0� `=E SCRIPTION DATE REV. TECTONIC WORK ORDER#: 12557.25 *z <�* BLDG.PETIONRMIT ODATE 025 0 The Unirac SOLARMOUNT (SM) Photovoltaic Panel Support System is a proprietary W framed photovoltaic panel support system that is installed on a roof. Tectonic 2 �,1 z Engineering Consultants, Geologists & Land Surveyors, D.P.C. (Tectonic) has =& reviewed the SM design methodology along with the U-Builder tool; a Unirac online 71249 design tool. The review included the following SM products, SM Light, Heavy Duty, st°NP 08/12/2024 and Standard rail with both the standard and pro hardware. Antonio A. Gualtieri, P.E. Tectonic has determined that the design is a rational approach and follows the Executive Vice President structural requirements of the following reference documents: Codes/Standards: • PROJECT NAME 2020 Building Code of New York State. • 2018 International Building Code by International Code Council. • ASCE/SEI 7-16 Minimum Design Loads for Buildings and Other Structures, by Q o p American Society of Civil Engineers with provisions from SEAOC PV-2-2017. W to o J • 2020 Aluminum Design Manual, by Aluminum Association. o O= 0 o F. This letter certifies that the structural analysis of the racking members, connections, Z rn o and components directly related to Unirac's system are in compliance with the O , o 0- O0 above codes. The design methodology is acceptable under components and �- o cladding loads associated with the building's roof structure when the system is Z Z CD CDWO installed in accordance with manufacturer specifications. If the loading criteria does >. Q p oo Z not meet Unirac's specifications, owner shall contact Unirac for a site-specific 0 J o certification. U)) r o :D O LO F- Attachments approved for the SM system to the structure include the following N O Z _ and is installed per Unirac's U-Builder report and installation guides: Q Q ■ Shingle Roof: L-Foot Flashkit Pro, Standoffs, Flashloc Comp, Flash Loc Duo, and Flash Kit Pro SB SHEET NAME SPEC SHEET Project Contact Info Project Contact Info SHEET SIZE 1279 Route 300 1 Newburgh,NY 12550 1279 Route 300 1 Newburgh,NY 12550 ANSI B 845.567.6656 Tel 1 845.567.8703 Fax 845.567.6656 Tel 1 845.567.8703 Fax I X 17" tectonicengineering.com tectonicengineering.com page 2 of 2 Equal Opportunity Employer Equal Opportunity Employer SHEET NUMBER PV-8