HomeMy WebLinkAbout52055-Z TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 52055 Date: 07/01/2025 Permission is hereby granted to: Steven Silberstein 1025 5th Ave Apt 5 GN New York, NY 10028 To: Install a two stacked Tesla Powerwall 27kwh unit to an existing single-family dwelling as applied for per manufacturers specifications. Premises Located at: 1496 Skunk Ln, Cutchogue, NY 11935 SCTM#97.-3-11.91496 Skunk Ln, Cutchogue, NY 11935 SCTM#97.-3-11.9 Pursuant to application dated 05/27/2025 and approved by the Building Inspector.. To expire on 07/01/2027. Contractors: Required Inspections: Fees: EV Charger $125.00 CO-RESIDENTIAL $100.00 ELECTRIC -Residential $100.00 Total $325.00 Building Inspector S TOWN OF SOUTHOLD —BUILDING DEPARTMENT "4 Town Hall Annex 54375 Main Road P. O. Box 1179 Southold, NY 11971-0959 (1-N Telephone (631) 765-1802 Fax (631) 765-9502 httDs://www.southoldtownny.gov Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only 5 PERMIT NO. Building Inspector: n Applicatibbs and farms must be filled ou0n their,edtirety incomplete ', Building Department appl�catidns will not be accepted."Wherethe Applicant is riot the owner,an ; ,` `town of Southold Owner'S Aut ion fofm(Page 2�sheU be completed. ; Date. )OF-PRC}PERTY� or r r Name: S1eVe n S i I llG al�l n SCTM # 1000-o-170 C)© 03:W-_6)1 . Uf) Pro ect Address: +q 6 'S K V Cu koaWe> JV\/ 035 r . Email: l to Phone#: 5 � 7.2oo C Mailing Address: )y96 L•ur)c CL}chcx3Lur- My IIA35 ✓ /i / /��i/ / ri/F///r / r r //rr, /r ri// �/ i r/�/ r //r e j � / y Name: I-slcc F-ocr -hons, �n� Tmr1'h Gl�1t-/ Mailing Address: 15 &rLLn-)MCtVj IRCj W &tJe i'C?d 1 714 Phone#: 5 Ifv c 2-73 Email: P3C c ) k4 .�'nr✓► /ii/i e// QESIGN'pROF rO ,pI,INFO�IV�A11fN ;, r � i/�� r //rr /r � „r Name: lu V) qP Mailing Address: 576® Le Uprilp- Sat4e-8.3-333 Pk -r)( 750--?4 -10 Phone#: �s3101'o� . y504- Email: Ghrisi;a%�xeru, rV . CONTRACTOR INFO�iMAT1ON r, Name: I-e-Slcc erx- cy 0prrCt4-,ons �r,C Mailing Address: It3 (grLtrnmCLn Qcj W)o Phone#: 0�5� Email: � p �-t�SIct. L6� 5W J13 - D,ESCRIPn, N OF;PROPOSCD CONSTRUCTION, r r ❑Alteration ❑Repair ❑Demolition Estim d Cnct of Prnipct�,� ❑New Structure ❑Addition ther.1ns II v a IeS q LQ011 S 9 $ .j50 Will the lot be re-graded? ❑Yes o Will excess fill be removed from premises? ❑Yes o 1 ,. ,.... rI r / ✓... J. / r / /rc. r r/n r / / /✓i 1 i r r l/r rr0/; 1 r/ - r / r � // Irr�H/J�r,lr;,�n,�//,�rra»„ } Existing use of property: �.�- 4L Intended use of property: 'Resicki Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes�hlo IF YES, PROVIDE A COPY. ,,.... r ✓., i r,. ,/ .�. ./., //.. / .rn. ,.. � u.,r i 1/ „ram.,. -,. r ,,.„, „ rr, ...,.r/ ,/ r ,.A. ,r < ./r,.✓fir / /� l r //1 „� / rJ ./, ,. y „.,r. ,r / .�i/,.,r �lrr,u/;�r�, // 1... �. ,.., /✓ r,, '1 „r,., 7// 11,r ,.//r/ ./, r J r u rr /r ,,/////, e�,/rJ,/i/�% ,!r/✓//,//,Jlr�,/pJ1J,41¢1, ;,ri✓J1 �„r,�;, ,/r �7"D1%iio /�r, » r ,n/�iG- � i1/,r, / ,/,,, �,r� r y;J�//, p/r,m// ,:.✓,r ,/„/„ .�� i„/,i,..J�i /-rr„r r,r„rr,.11e.a;�, ///ri/:/,J ,,,,,: // ,,,,,;. /„ ,,., ,..,.. /,/n,r/,,,, rr r...: r // / /i p i,r/ i„//G:,,; ,... / l/ l / �,,„, „, ��J (��r ±�� »„�,, ,�7A��,,,.,,,,.r ,,,r, ,„„ �,,,,,»,,,,r, % a/,x✓�i/f „riu4�.G_! ,,,r;,r/, ,„ l�i, /irei. ,,r�„� Application Submitted By(print name): thorized Agent ❑Owner i�ft-10-thy Q >4 Signature of Applicant: �►-n t4% Gate. J STATE OF NEW YORK) SS: COUNTY OF gS&aQ ) being duly sworn, deposes and says that (s)he is the applicant (Name of individua(signing contract) above named, (S)he is the Contractor,Agent, Coro6ofite Officer, etc.) o of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file,'J.hf, o D application;that all statements contained in this application are true to the best of his/her knowledge and belief;j•na o that the work will be performed in the manner set forth in the application file therewith. n, �, D a ` o o o M Sworn before me this CA � 0N o C? 66 'n CZ{ r Y � CC co Z / ICA,da of20 � m Q No Public ca -< N p v � '�4 PROPERTY OWNER AUTHORIZATION (Where the applicant is not the owner) s6eln S I" . n residing at N96 SklijnKla CLI Ac9jc— j do hereby authorize alik 11 to apply on my behalf to the Town of Southold Building Department for approval as described her in, � - 4 14 2025 Owner's Signature Date Steven Silberstein M Print Owner's Name 2 f BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD Town Hall Annex - 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 iamesh@southoidtownnv.gov — seand southoldlgVf ny_gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Company Name: lSon 40 G Electrician's Name: " n 10 License No.: 50" 1 Elec. email: JKcxn` &D-kSln Lc7/1it Elec. Phone No; •D/a6 ❑I request an email copy of Certificate of Compliance Elec. Address.: _,� 1�k. La -& .V 64 S -/ JOB SITE INFORMATION (All Information Required) Name: Address: / // Cross Street: Phone No.: 7200 Bldg.Permit#: 5 c" email: Tax Map District: 1000 Section: 07, Block: 03, Oil Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly):. Square Footage: Circle All That Apply: Is job ready for inspection?: El YE-S 1S<0 El Rough In Final Do you need a Temp Certificate?: ;�g YES E] NO Issued On Temp Information: (All information required) Service Size 1:11 PhF]3 Ph Size: A # Meters Old Meter# ❑New service[:]Fire Reconnect[:]Flood Reconnect[:]Service Reconnect❑Undergroun verhead # Underground Laterals al D2 H Frame 0 Pole Work done on Service? Y MN Additional Information: PAYMENT DUE WITH APPLICATION ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES BP4Sa055 - AsScssbRS A AMPERE AC ALTERNATING CURRENT BLDG 1. THIS SYSTEM IS GRID—INTERTIED VIA A UL—LISTED BUILDING CONC CONCRETE DC DIRECT CURRENT ENT POWER—CONDITIONING INVERTER. EGC EQUIPMENT GROUNDING CONDUCTOR E 2. A NATIONALLY — RECOGNIZED TESTING EXISTING EMT ELECTRICAL METALLIC TUBING FSB LABORATORY SHALL LIST ALL EQUIPMENT IN FIRE SET—BACK GALV GALVANIZED GEC GROUNDING COMPLIANCE WITH ART. 110.3. ELECTRODE CONDUCTOR GND GROUND HDG HOT 3. WHERE ALL TERMINALS OF THE DISCONNECTING DIPPED GALVANIZED I CURRENT Imp CURRENT AT MEANS MAY BE ENERGIZED IN THE OPEN POSITION, MAX POWER Isc SHORT CIRCUIT CURRENT kVA A SIGN WILL BE PROVIDED WARNING OF THE KILOVOLT AMPERE kW KILOWATT LBW LOAD HAZARDS PER ART. 690.17. BEARING WALL MIN MINIMUM (N) NEW NEUT 4. EACH UNGROUNDED CONDUCTOR OF THE NEUTRAL NTS NOT TO SCALE OC ON CENTER PL MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY PROPERTY LINE POI POINT OF INTERCONNECTION PHASE AND SYSTEM PER ART. 210.5. PV PHOTOVOLTAIC SCH SCHEDULE S STAINLESS 5. CIRCUITS OVER 250V TO GROUND SHALL COMPLY STEEL STC STANDARD TESTING CONDITIONS TYP WITH ART. 250.97, 250.92(B). TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V 6. DC CONDUCTORS EITHER DO NOT ENTER BUILDING VOLT Vmp VOLTAGE AT MAX POWER Voc VOLTAGE OR ARE RUN IN METALLIC RACEWAYS OR AT OPEN CIRCUIT W WATT 3R NEMA 3R, RAINTIGHT ENCLOSURES TO THE FIRST ACCESSIBLE DC DISCONNECTING MEANS PER ART. 690.31(E). 7. ALL WIRES SHALL BE PROVIDED WITH STRAIN RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY UL LISTING. ALL WORK TO COMPLY WITH SECTION R327 OF THE 2020 RESIDENTIAL 8. MODULE FRAMES SHALL BE GROUNDED AT THE UL — LISTED LOCATION PROVIDED BY THE CODE OF NYS. MANUFACTURER USING UL LISTED GROUNDING HARDWARE. 9. MODULE FRAMES, RAIL, AND POSTS SHALL BE BONDED WITH EQUIPMENT GROUND CONDUCTORS. VICINITY MAP INDEX Sheet 1 COVER SHEET Sheet 2 SITE PLAN Sheet 3 THREE LINE DIAGRAM f Sheet 4 GARAGE FLOOR PLAN Sheet 5 POWERWALL LOCATION LICENSE GENERAL NOTES Sheet 6 POWERWALL MOUNTING DETAIL 1. ALL WORK SHALL COMPLY WITH THE 2020 NYS Sheet 7 BOLLARD DETAIL UNIFORM CODE. Cutsheets Attached 2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2017 NATIONAL ELECTRIC CODE. 3. ALL WORK SHALL COMPLY WITH THE 2020 NYS FIRE CODE. MODULE GROUNDING METHOD: WEEB 4. ALL WORK SHALL COMPLY WITH THE 2020 BUILDING CODE OF NYS. REV BY DATE COMMENTS AHJ: Southold Town 5. ALL WORK SHALL COMPLY WITH THE 2020 REV NAME DATE COMMENTS RESIDENTIAL CODE OF NYS. 6. ALL WORK SHALL COMPLY WITH THE 2020 UTILITY: PSE&G—Long Island EXISTING BUILDING CODE OF NYS. x CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER: J B-119 316 7 00 CUSTOMER: DESCRIPTION: DESIGN:CONFIDENTIAL CONTAINED SHALL NOT BE USED FOR THE Steven Silberstein 27 KWH ENERGY STORAGE SYSTEM Evan Miller EXCEPT C BENEFIT OF ANYONE T E �1"' L n SHALL IT BE DISCLOSED N WHOLE OR N NOR MouNTING SYSTEM: 1496 Skunk Ln PART TO OTHERS THE RECIPIENTS ORGANIZATION, EXCEPT OUTSIDE N CONNECTION WITH MODULES: C u t c h o g u e, NY 11935 THE SALE AND USE OF THE RESPECTIVE TESLA EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME: SHEET: REV: DATE PERMISSION OF TESLA INC. 5165787200 COVER SHEET 1 1 A 5/9/2025 NY NI-4V NEW 0 YU'�f9 Front Of House r` e 101980 ss1� P`w LEGEND OQ (E) UTILITY SERVICE METER Q DISTRIBUTION PANEL LOAD CENTER p AC DISCONNECT (E) PV ARRAY �� SOLAR INVERTER (E)DRIVEWAY � p AUTOMATIC RELAY (E) PV COMBINER O ENERGY STORAGE SYSTEM PANEL (E) POWERWALL (E) INVERTER G > cJ .elf^ � (E) GATEWAY EXTERNAL DISCONNECT " SWITCH WARNING LABELS PROVIDED AT APPLICABLE EQUIPMEN BOLLARDS TO BE INSTALLED TO MITIGATE IMPACT PROTECTION CONCERNS 0 STANDOFF LOCATIONS — COND IT RUN INSTALLATION SHALL MEET 2020 RESIDENTIAL NYS CODE, SECTION R327. GATE FENCE SYSTEM WiLI BE INSTALLED AS PER NFPA 70. HEAT PRODUCING VENTS ARE RED ROOMS ALLOCATING ESS WILL BE PROVIDED WITH SMOKE ALARMS IN ACCORDANCE It 1 INTERIOR EQUIPMENT / CONDUIT IS DASHED WITH SECTION R314 PER R327.7. HEAT DETECTORS OR-HEAT ALARMS TO BE INTERCONNECTED TO SMOKE ALARMS AS -- T REQUIRED. ROOMS CONTAINING ESS TO BE PROTECTED BY NO LESS THAN 5/8" TYPE SITE PLAN X GYPSUM BOARD IN ACCORDANCE WITH R327.8. N ESS TO BE INSTALLED OUT OF VEHICULAR IMPACT. WHEN INSTALLED INSIDE THE GARAGE, THEY WILL BE WALL MOUNTED BEHIND THE WALLS HOLDING GARAGE DOOR Scale:1/16" = 1' W E IN ACCORDANCE NTH R327.9. 01, 16' 32' CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMeEx J B-119 316 7 wsmm DEmTm DESIGII: _ CONTAINED MALL NOT E USED FOR THE Steven Silberstein 27 KWH ENERGY STORAGE SYSTEM Evan Miller "�' � S BENEFIT IT BEMYONE DI OSm�vIMOOM O MA R INC., "� uO 1496 Skunk Ln PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION,EXCEPT IN CONNECTION IMTH ►ODM' CutChogue, NY 11935 THE SALE AND USE OF THE RESPECIVE TESLA EQUIPMENT,WITHOUT THE WRITTEN NVFRIFR PACE NAME SHEET. REV: DATE: PERMISSION OF MLA INC. 5165787200 SITE PLAN 2 A 5/9/2025 (E) Sunny Boy • (E) BACKUP (E) 125A Square SB3000TL—US-22 (E) WIRING GATEWAY 1.0 AC DISCONNECT (N) 200A LOAD CENTER D LOAD CENTER 3 kW INVERTER EXISTING 9.065 KW DC SYSTEM SIZE Aj B C (E) (13) Sunpower SPR-245 200A 2P r, 175A 50�2P 20�2P 245 W PV MODULES 4 3 - \le\ — Y (E) Sunny Boy XT SB 5000TL-US-22 EXTERNAL AL 5 kW INVERTER 1 DISCONNECT SWITCH (E) (24) Sunpower SPR-245 30A2P 245W PV MODULES TO 120/240V 200A 2P SINGLE PHASE UTILITY SERVICE Ell • (E) LOADS (E) 200A AC DISCONNECT DISTRIBUTION E PANEL 30�2P 2 2 (E) POWERWALL AC DISCONNECT E 30A2P 2 2 (E) POWERWALL AC DISCONNECT E 30A2P 2 Z F POWERWALL AC DISCONNECT E 30�2P 2 2 F POWERWALL AC tONDUCTOR TABLE Ref Qty Description Size (AWG) Min EGC Conduit Length Imp Vmp 1. GROUND NEUTRAL BOND TO BE COMPLETED IN SERVICE EQUIPMENT (A) A 1 200A Main Circuit Breaker, 2—Pole, 24OV, 22kAIC Ref Type Qty (Cu) (AI) (AWG, Cu) (Cu) (AI) (ft) (AAC) (VAC) 2. CONDUIT RUNS MAY BE CONDENSED DUE TO SITE CONDITIONS AND/OR 1 Disconnect; 200A, 240Var, Fusible, NEMA 3R: 2P, 3W, Lockable 1 THWN-2 3 $2/0 #14 00 #06 2" PVC 2" PVC 2ft — 240 INSTALLATION EASE. ALL CONDUIT FILL DERATES AND PROPER CALCULATIONS HAVE BEEN COMPLETED PER NEC CHAPTER 9, TABLE 4. B 1 Ground/Neutral Kit; 200A General, Heavy Duty(DG, DH), NEMA 1, 3R 2 THWN-2 3 #10 #08 #10 PVC Jacketed MC 1" EMT 2ft — 240 3. SOLAR SHUTDOWN DEVICE TO BE INSTALLED FOR SYSTEM RAPID SHUTDOWN 2 Fuse; 175A, 250V, Class RKS: Time Delay, 200kA I.R. 3 THWN-2 3 #2/0 14/0 #06 2" PVC 2" PVC 2ft — 240 (RSD) IN ACCORDANCE WITH ARTICLE 690 OF THE APPLICABLE NEC. 1 Class R Fuse Kit 4. CONDUIT TYPE CAN CHANGE DUE TO SITE CONDITIONS AND WILL FOLLOW 4 THWN-2 3 #2/0 #14/0 #06 2" PVC 2" PVC 5ft THE NEC REQUIREMENTS FOR THAT CONDUIT TYPE. 4 Breaker, 30A/2P, 2 Spaces SITE 'SPECIFICATIONS 1 Breaker, 50A/2P, 2 Spaces C Eaton #BRP20NC20OR: Load Center (BR Convertible), 200A, NEMA 3R, 10 kAIC, 1P, Main Panel Rating (E) 200A 1 20.Spaces, 120/240 V Main Breaker (E) 200A 1 Eaton BRPL200: Main Lug Kit, 200A Rating 4 IDisconnect; 30A, 240Vac, Non—Fusible, NEMA 3R: 2P, 2W, Lockable General Notes DC Ungrounded E Inverters 4 Ground/Neutral Kit; 30A, General Duty(DG) Panel Number F 2 AC Powerwall 3012170-05—E; ASY, AC POWERWALL2.2, 50F Meter Number 80385032 Service Entrance Underground CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: J B-1193167 00 CUSTOMER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT USED FOR THE Steven Silberstein 27 KWH ENERGY STORAGE SYSTEM Evan MillerBENEFIT OF T S L n SHALL IT BE NYONE DISCLOSED EXCEPT DISCLOSED IN WHOLE OR IN NOR MOUNTING SYSTEM: 1496 Skunk Ln ORGANIZATION, XCEPTTIDE IIN CONNECTIPART TO OTHERS THEION WITH MODULES: Cutchogue, NY 11935 THE SALE AND USE OF THE RESPECTIVE TESLA EQUIPMENT, WITHOUT THE WRITTEN INVERTER PAGE NAME SHEET: REV: DATE: : PERMISSION OF TESLA INC. 51 65787200 THREE LINE DIAGRAM 3 A 5/9/2025 vtiv of NEW 18 FES DOOR TO [Structural Aspects Only] INTERIOR BOLLARDS TO BE INSTALLED TO MITIGATE IMPACT PROTECTION CONCERNS INSTALLATION SHALL MEET 2020 RESIDENTIAL NYS CODE, SECTION R327. SYSTEM WILL BE INSTALLED AS PER NFPA 70. ROOMS ALLOCATING ESS WILL BE PROVIDED WITH SMOKE ALARMS IN ACCORDANCE WITH SECTION R314 PER R327.7. HEAT DETECTORS OR HEAT ALARMS TO BE INTERCONNECTED TO SMOKE ALARMS AS REQUIRED. ROOMS CONTAINING ESS TO BE PROTECTED BY NO LESS THAN 5/8" TYPE CAR CAR X GYPSUM BOARD IN ACCORDANCE WITH R327.8. ESS TO BE INSTALLED OUT OF VEHICULAR IMPACT. WHEN INSTALLED INSIDE THE 20� PARKING PARKING GARAGE ACCORDANCE WILL BE MWITH R327L9 MOUNTED BEHIND THE WALLS HOLDING GARAGE DOOR NEW WINDOW (2) ESS BOLLARD . HEAT DETECTOR � NEW HEAT DETECTOR TO BE INSTALLED IN GARAGE EXISTING EXISTING 5/8" Type X Gypsum Board present on garage walls and ceiling (2) ESS dl GARAGE DOOR CONFIDENTIAL- THE INFORMATION HEREIN JOB NUmm J B-119 316 7 00 CUSM10IER. DMPM. DESIM CONTAINED MALL NOT BE USED FOR THE Steven Silberstein 27 KWH ENERGY STORAGE SYSTEM Evan Miller BING ENEFIT IT BE DISCLOSED INN WHOLE OR N'"� u�" sY51E►t 1496 Skunk Ln T IEEEa L PART TO 07HERS OUTSIDE THE RECIPIENTS ORGANIZATION.EXCEPT IN CONNECTION WITFI MMUL s: Cutchogue, NY 11935 THE SALE AND USE OF THE RESPECTIVE TESLA EQUIPMENT, WITHOUT THE WRITTEN [INVERM PAGE NAME: SHEET: W. DATE:PERMISSION OF TESLA INC. 5165787200 GARAGE FLOOR PLAN 4 A 5/9/2025 . f1lY' 101980 NOTES: 1 . 41" DIA MIN PAINTED STEEL PIPE 8 „ BOLLARD PER GRAINGER OR EQUAL 2. 36" MIN HEIGHT 3. SPACED NOT MORE THAN 48" BETWEEN POSTS 4. 8" X 8" FLANGE MOUNT WITH HILTI ANCHOR BOLTS OR EQUAL 5. CONTRACTOR SHALL VERIFY POST TENSIONING LOCATION AND REINFORCEMENT LOCATION IN EXISTING CONCRETE SLAB PRIOR TO 3' (4) 1 /2" EXPANSION WEDGE ANCHOR INSTALLATION OF ANCHORS AND ENSURE PROPER CLEARANCE KWIK BOLT TZ—SS 304 W/ 23" (REINFORCEMENT DIAMETER MINIMUM) BETWEEN ANCHORAGE EMBED PER ESR-1917 SYSTEM AND EXISTING REINFORCEMENT IS ACHIEVED. 6. MAXIMUM APPLIED LOAD OF 800LBS HORIZONTALLY AT 2'-311 r HEIGHT. SM Note: The detail shows the capacity of a surface mounted bollard barrier to rm F resist, deflect, or visually deter an anticipated impact scenario associated with a SURFACE MOUNT PIPE BOLLARD residential garage in accordance with Section 312.3 of the 2018 IFC (2019 CFC) WS CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBBi: J B-119 316 7 00 WSJ O WN: DMM- CONTAINED SHALL NOT BE USED FOR THE Steven Silberstein 27 KWH ENERGY STORAGE SYSTEM Evan Miller a BENEFIT OF ANYONE EXCEPT TESLA INC.,NOR MOUNTING SySM SHALL IT BE DISCLOSED IN WHOLE OR IN 1496 Skunk Ln PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION,EXCEPT IN CONNECTION WITH MODULES Cutchogue, NY 11935 THE SALE AND USE OF THE RESPECTIVE 7ESLA EQUIPMENT.WITHOUT THE W PAGE NALff SHEET REV DATE RITTEN INVERTER: PERMISSION OF TESLA INC. 5165787200 BOLLARD DETAIL 5 A 5/9/2025 NY IlL V'1 ft1E �/ �ay. t r � . +' E ! AAJ!! 3.} , all ��d4 ty + ! � c P � � '�•,,ww F � �j i I�� 1 x #�3�""k �y,�1 "C,/yd�l?�' "�" V I nd Ildls i e4 J ao `n °,, x (4td �II�.�;ulll IIIF±I,I im l Fs ! ( + #1 aila' wY ,�tky L b WINDOW O � S�1 �F" rt �,I .R k66 .�r ! 6 _ . R t, I 6 is !tJ?._sF76 Fly-a ��" � ,�:i'., r .' I jl I dd '6;-- I'I I�. ���! � ,}�' �FI �r, ,�� �f l ilp� ,I� � i� a 3 ! t `'•�, t t c, � I' i ��j r I, 6 1 a „i1;: , �a..- 1 A6, �� y •i �V 6 � J =,I i� is I ��tr[;�.�I•, �+}���I k F�'' 6Y�1� � ���3€,:�� s � s r FT*�` ENERGY ENERGY STORAGE STORAGE SYSTEM SYSTEM (2 Stacked) (2 Stacked) EXISTING NEW 411, 11,44�Aft�1�4 l (N) BOLLARD (N) BOLLARD yy I6 r EQUIPMENT ELEVATIORI EXTERIOR ! �11 a k` ft p f i r�y l i��ir ` k I ` �4 a�? If ��r! lG l A*�•+..... NTS I .fig E 1Ntd ��......� �•'Fy..s.:bpC:Ii§: C ��.xl�.�����r J �». NIEW POWERWALLS (2- STACKED) NEW BOLLARD EXISTING POWER'WALLS INSTALLATION SHALL MEET 2020 RESIDENTIAL NYS CODE, SECTION R327. SYSTEM WILL BE INSTALLED AS PER NFPA 70. (.2 STACKED) ROOMS ALLOCATING ESS WILL BE PROVIDED WITH SMOKE ALARMS IN ACCORDANCE WITH SECTION R314 PER R327.7. NEW BOLLARD HEAT DETECTORS OR HEAT ALARMS TO BE INTERCONNECTED TO SMOKE ALARMS AS REQUIRED. ROOMS CONTAINING ESS TO BE PROTECTED BY NO LESS THAN 5/8" TYPE X GYPSUM BOARD IN ACCORDANCE WITH R327.8. ESS TO BE INSTALLED OUT OF VEHICULAR IMPACT. WHEN INSTALLED INSIDE THE GARAGE, THEY WILL BE WALL MOUNTED BEHIND THE WALLS HOLDING GARAGE DOOR IN ACCORDANCE WITH R327.9. CONFIDENTIAL— THE INFORMATION HEREIN JOB NUYBf]i: J B-119 316 7 00 amma D 'm O _ CONTAINED SHALL NOT BE USED FOR THE Steven Silberstein 27 KWH ENERGY STORAGE SYSTEM Evan Miller 'r JC' r.... n BENEFIT OF BE COED IN�ORINC.,NOR YOIIN>WG SYSiEIt 1496 Skunk Ln ORGANIIZZATIONTHERS N.EXCEPT IN CONNECTIONCOON THE NEECTIONN VA7H voouLEs Cutchogue, NY 11935 THE SALE AND USE OF THE RESPECTIVE TESLARIA OFEQUIPMENT,WITHOUT THE WRITTEN TES 5165787200 PACE NAME- SHEER LOCATION SHEET RM 5 A DATE- 5/9/2025 PERMISSION TESLA INC. POWERWALL FASTENER SCHEDULE' POWERWALL INSTALLATION INFORMATION: WALL TYPE MODEL DIAMETER EMBEDMENT FASTENERS PER CORNER ESR# UNISTRUT REQUIRED? WOOD STD WOAD SCREN' Y4 o ?74' t NA YES ❑ NO t� 1. POWERWALLS TO BE INSTALLED PER FASTENER SCHEDULE BASED ON WALL TYPE GOWRM SCM wo , . NA NA AND SITE SPECIFIC CONDITIONS. ORS ORCREIE CMU SOJSPOw TrtE?I ND �6•o �• � 1056 NA 2. DO NOT MOUNT BELOW OR ABOVE WINDOWS OF THE SAME STORY. 3. IF LOCATION NEEDS TO BE CHANGED, PLEASE CONTACT DESIGN TEAM. "�' � iMLO 4. ANY UNUSUAL FRAMING NEAR THE POWERWALL THAT MAY COMPROMISE THE WALL BRICK "IL" KYA`CONN D 'w1 NA NA STRUCTURAL INTEGRITY SHALL BE RELAYED TO THE DESIGN TEAM PRIOR TO INSTALL. BRICK "rt M�� xti ' ESR-"43( "A 5. WHEN INSTALLING POWERWALL+ THE INVERTER IS A SINGLE UNIT AND CANNOT BE �® sHEIT max`am x �' �" I 'm ❑ NO 0 STACKED. WHEN INSTALLING A STACKED ARRANGMENT ONLY ONE POWERWALL+ AND 1. INSTALLER TO CHOOSE FASTENER BASED ON FIELD CONDITIONS, WALL TYPE, AND EASE OF INSTALL ONE ADDITIONAL POWERWALL CAN BE INSTALLED. THE �ILARGEST STACKING 2 ATCSHORTTPERIOD)tISNAT OR BELOWE$3 C1Z5BE USED WHEN UNIT(S) ARE MOUNTED ON THE GROUND AND SEISMIC SS (SRA CONFIGURATIONS ALLOWED BY THE MOUNTING BRACKETS ARE 3 POWERWALL UNITS 3. 1 CONCRETE & CMU ESR FASTENER CAN BE USED WHEN UNIT(S) ARE MOUNTED ON THE GROUND AND SEISMIC Ss (SRA AT SHORT PERIOD) IS AT OR BELOW Ss = 2.5 AND REGIONAL WIND SPEED (3—SECOND GUST) IS AT OR BELOW 170MPH OR 1 POWERWALL+ AND 1 POWERWALL UNIT 4. COLD FORMED STEEL MINIMUM 25 GAUGE REQUIRES 3 FASTENERS PER CORNER, BUT 1 FASTENER PER CORNER CAN BE USED WHEN STEEL STUDS ARE 8 GAUGE OR THICKER WHEN BOX IS CHECKED DIVERSITECH PAD ACP24362 IS APPROVED FOR NY- E] A SINGLE OUTDOOR POWERWALL GROUND MOUNT AND DIVERSITECH PAD .`�,QF I�IF ✓ ACP36362 IS APPROVED FOR UP TO 2 STACKED USING A POWERWALL+ �, p, 0 AND A POWERWALL iUNIT OR-2 POWERWALL UNITS 44. a � REFER TO FASTENER SCHEDULE � FOR NUMBER OF FASTENERS .. " POWERWALL UNIT PER CORNER / Zf 2t9'�'�p 10�980 ,( EXAMPLE SS���Q` ONE FASTENER o o o p l WAIL IN ANY HOLE PER CORNER EXAMPLE TWO FASTENERS o p o O IN ANY HOLE PER CORNER FASTENER TO WALL PER FASTENER SCHEDULE (N) POWERWALL BRACKET, POWERWALL UNIT NOT POWERWALL SHOWN FOR CLARITY WALL BRACKET II PnrVw«�ww.,.r,.1+x..w1r�aweu,J WALL ATTACHMENT: GROUND MOUNT ATTACHMENT: FRONT VIEW SIDE VIEW TWO POWERWALL STACK ors POWERWALL NTS CONFIDENTIAL— THE INFORMATION HEREIN JOB NIgIBEti J B-1193167 0 0 a,sTom D110'� DESIGIA _ CONTAINED sHAu NOT USED FOR THE Steven Silberstein 27 KWH ENERGY STORAGE SYSTEM Evan Miller "�" �"' Jc L n SHAEFl IT BE DISCLOSED p ANYONE IN �OR IN NOR ImllN7lNc sYSIE1t 1496 Skunk Ln PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION.EXCEPT IN CONNEcnm WITH Cutchogue, NY 11935 THE SALE AND USE OF THE RESPECTIVE TESLA EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME SHEET: REV: DATE PERMISSION OF TESLA INC mysm 5165787200 POWERWALL MOUNTING DETAIL 6 A 5/9/2025 Label ..- • • BACKUP LOAD CENTER :LQ ON Per Code: TRI POWER SOURCE Per Code: 408.4 18 SECOND SOURCE IS PHOTOVOLTAIC SYSTEM THIRD SOURCE IS ENERGY STORAGE SYSTEM 1 Label • • CAUTION DO NOT ADD NEW LOADS Per ••': Label L• • ' WARNING ' Per ..- THIS EQUIPMENT FED BY Label Locati• 1 MULTIPLE SOURCES.TOTAL RATING OF ALL OVER CURRENT CAUTION DEVICES,EXCLUDING MAIN THIS PANEL HAS SPLICED FEED Per ••- SUPPLY OVERCURRENT DEVICE, THROUGH CONDUCTORS. SHALL NOT EXCEED AMPACITY OF BUSBAR. LOCATION OF DISCONNECT AT ENERGY STORAGE BACKUP LOAD PANEL NOMINAL ESS VOLTAGE 12Qr240V Label Locat Label Location: (MSP) CAUTION Per Code: DUAL POWER SOURCE Per ..-: 706.7.D • •- marked in field per code) SECONDSOURCE IS ARC FAULT CLEARING ENERGY STORAGE SYSTEM TIME FROM ESS: 67f11S DATE OF Label Location: CALCULATION: ENERGY STORAGE SYSTEM ON SITE LOCATED WITHIN LINE OF SIGHTPer •• 1• Label • • ENERGY STORAGE SYSTEM ON SITE LOCATED ON ADJACENT WALL Per ••- 1. Label • • ENERGY STORAGE SYSTEM ON SITE LOCATED ON OPPOSITE WALLPerCode: 70• Label • • ENERGY STORAGE SYSTEM ON SITE LOCATED INSIDEPerCode: 70. ` AC Disconnect Backup Load Center (MSP): Main Service Panel NEC 2017Default Label - POWERWALL 2 TYPICAL SYSTEM LAYOUTS Tesla Powerwall 2 is a fully-integrated AC battery system for WHOLE HOME BACKUP residential or light commercial use. Its rechargeable lithium-ion s ='n• T battery pack provides energy storage for solar self-consumption, V adorall time-based control, and backup. j Powerwall`s electrical interface provides a simple connection to Solar any home or building. Its revolutionary compact design achieves market-leading energy density and is easy to install, enabling owners to quickly realize the benefits of reliable, clean power. - . . .. ...ems=: J.�►�- � o® �~ Solar inverter - ---------•--- Main panel Backup Gateway Utility meter Grid PERFORMANCE SPECIFICATIONS MECHANICAL SPECIFICATIONS including I service disconnect Model Numbers 1092170-xx-y,2012170-xx-y, Dimensions 1150 x 753 x 147 mm 05.3 x 29.6 x 5.75 in)' T=s L R - - 3012170-xx-y - Weight 114 kg (251.3 Ibs)^ AC Voltage(Nominal) 120/240 V - - -- - --- - -- - - - _ Mounting options Floor or wall mount Feed-In Type Split Phase - -- - - - Grid Frequency 60 Hz `Dimensions and weight differ slightly rf manufactured before March 2019. Contact Tesla fo;additional information. Total Energy 14 kWh Powerwall Whole home -- -- -- - -- - ---- - --------- - -- - 753 mm 147 mm backup - Usable Energy 13.5 kWh' (29.6 in) (5.75 in) Real Power,max continuous 5 kW(charge and discharge) Real Power,peak(10s,off-grid/backup) 7 kW(charge and discharge) Apparent Power,max continuous 5.8 I(VA(charge and discharge) = Apparent Power,peak a 7.2 kVA(charge and discharge) (10s,off-grid/backup) _ PARTIAL HOME BACKUP Maximum Continuous Current 24 A 1150 mm Maximum Output Fault Current 32 A (4,,s-in) Optional Overcurrent Protection Device 30 A " w Load Start Capability 88-106 A LRA' Solar Imbalance for Split-Phase Loads 100% Power Factor Output Range +/-1.0 adjustable Power Factor Range(full-rated power) +/-0.85 Internal Battery DC Voltage - 50 V o o o • Maximum Supply Fault Current 10kA ENVIRONMENTAL SPECIFICATIONS Solar inverter Round Trip Efficiency 9011, Operating Temperature -200C to 500C(-40F to 1220F)= Sub panel Backup Gateway Main panel Utility meter Grid Warranty 10 years Operating Humidity(RH) Up to 100`t.condensing Values provided for 250C(770F),3.3 kW charge/discharge power. Storage Conditions -200C to 300C(-40F to 860F) T c 5 L n Load start capability may vary. Up to 954 PH,non-condensing 1AC to battery to AC.at beginning of life. State of Energy(SoE):251G initial COMPLIANCE INFORMATION Maximum Elevation 3000 m(9843 ft) Certifications UL 1642.UL 1741,UL 1741 SA,UL 1741 SB,UL 1973, Environment ndoor and outdoor rated I" I UL 9540.IEEE 1547-2018.UN 38.3 Enclosure Type i-JEMA 3R - — - - - - — - Powerwall Backup loads Home loads Grid Connection Worldwide Compatibility Ingress Rating IP67(Battery&Power Electronics) IP56(Wiring Compartment) Emissions FCC Part 15 Class B.ICES 003 - Wet Location Rating Yes Environmental RoHS Directive 2011/65/EU - - - Noise Level @ 1m < 40 dBA at 300C(860F) Seismic AC156,IEEE 693-2005(high) Fire Testing Meets the unit level performance criteria of UL 9540A `Performance may oe de-rated at operating temperatures below 100C(SO'F)or greater than 430C(1090F). I Ja-B4,"I•. lrr-2i?_i -n2 T = 5 L n TESLA.COM,'ENERGY T = 5 L n TESLA.COM,ENERG•, 1 Tesla Road,Austin,TX 78725 a L= P 650 6815100 F 650 6815101 Version#9.5 May 12, 2025 RE: Powerwall Certification Letter Project/Job# 1193167 Project Address: Silberstein Residence 1496 Skunk Ln Cutchogue, NY AHJ Southold Town Testa Office Bethpage To Whom it may concern: The installation manual for the Tesla Powerwall was reviewed for wall mounting considerations. Based on the weight of the unit and.the attachment layout of the mounting bracket, it was determined that the following fasteners should be used: For mounting to walls with wood studs with the PW bearing on the ground: 4- 1/4 in.Wood Screws with a minimum embedment of 2.5 In addition,the wall structure has been verified as sufficient to support the additional load imposed by the Tesla PowerWall unit. Ny ti�a�r�er�r Sincerely, ��� .To Yfj�� Tesla Energy4 A, y7F Y '�� ESS10@� 'WALL DESIGN AND LOADING SUMMARY Applicable Codes: IBC 2018,ASCE 7-16 see s alt Membere Wall Height 8.0 ft. Stud Size 1.5 x 3.5 Stud Spacing 16 in.O.C. Lumber Type DF Stud Trib. Roof Loading 10.0 ft. • es -;1110 --e e.e e., o e,o DL, LL,SL PSF(DL adjusted for pitch) Compression Stress(PSI) DL LL SL DL LL SL Roof 9.9 20.0 20.8 25.2 0.0 52.8 Ceiling 5.0 12.7 First Floor Wall 8.5 17.3 Second Floor&Ceiling 0.0 0.0 0.0 0.0 Second Floor Wall 0.0 0.0 55 psi; ; i,'Op3i psi 's ie 0.1 Powerwall Dead Load (Including Brackets) 277 lbs No.Stacked PowerWall Units 2 Note:PW bearing on the Dead Load per Stud No.Studs 2 300 Ibs ground Resulting Axial Stress = ` 57 psi Eccentric Moment Total 2265 Ibs-in Moment per Stud No.Studs 2 1133 Ibs-in Resulting Bending Stress = '185 psi • e e 0 4 e.e Wind Speed(ULT) 130 mph Risk Category 2 Exposure Category C PowerWall Elevation 0-15 ft. Distance of PowerWall(s)to Comer of Building 8.0 ft. Directionality Factor 0.85 Topographic Factor 1.00 Velocity Pressure Exposure Coefficient 0.85 Resulting Bending Stress = 1202 psi ee o s.e Component Amplification Factor ah 1.00 Soil Site Class D Component Response Modification Factor RP 2.5 SRA at Short Period SS 0.175 Component Importance Factor IP 1.00 SRA at 1 s Period Sl 0.050 Component Operating Weight WP 600.0 Ibs Wall Dead Load 8.50 psf Wall Bending Stress = 24 p_siY. Battery Axial Stress = 1",psi Battery Bending Stress = 99 psi Eccentric Battery Stress WALE'ANALYSIS RESULTS I r Governing Load Combo DL LL SL W E Total D+.6W 55 psi -- -- -- -- 55 psi b- • • e Governing Load Combo DL LL SL W E Total D+.6W 0 psi -- --- 486 psi --- 486 psi Governing Load Combo DL LL SL W E Total D+W 0 psi -- -- 721 psi --- 721 psi Load Duration Factor Co - 1.60 Repetive Member Factor Cr = 1.15 Size Factor: Bending Size Factor:Compression CF = 1.10 CF = 1.05 Based on NDS Eqn.3.9-3.... Fc = 850.0 psi 0.39 <= 1.05 Pass Fb = 700.0 psi E = 1400000.0 psi Based on NDS Eqn.3.9-4.... Emin = 510000.0 psi 0.01 <= 1.05 Pass • e a e FB = 721 psi F'bl = 1417 psi r - �; 1 os� Bass � i HARDWARE DESIGN AND LOADING SUMMARY I o- Fastener Type 1/4 in.Wood Screw #Top Fasteners 2 Fastener Diameter 0.25 in. #Bottom Fasteners 2 Fastener Area 0.049 sq.in. Total Fasteners 4 Vertical Distance Between Fasteners 19.75 in. PowerWall Battery Version PW3 PowerWall Battery Weight 300.0 Ibs No.Stacked PowerWall Units 2 Panel Depth 7.60 in. Wall Finish Depth 1.00 in. Half Panel Depth 3.80 in. Total Wall Depth 3.50 in. Frame Depth 1.00 in. Half Wall Depth 1.75 in. Total Eccentricity = 7.55 in. Eccentricity Moment = 2265 Ibs-in T and C Components = 115 Ibs/fastener row T per Fastener = 57 Ibs ' Shear per Fastener = 7'5 ibs Approximate Battery Wind Load 34.38 psf Dimensions Width 24.00 in. Height 43.50 in. Surface Area 1044.00 sq.in. Suction Force = 249 Ibs Tension per Lag = (; fit tbs Seismic Vertical 8 Ibs FTmc.nd ment 63 Ibs-in Shear per lag 2 Ibs C Components 0 Ibs/fastener row Seismic Vertical = 8 Ibs Seismic Horizontal = 25 lbs Withdrawal per lag = �., 0 Ibs ` From Horizontal Fp V per fastener = I T 'ibs From Vertical Fp T per fastener = 6 lbs i From Vertical Fp Eccentricity(top fasteners only) HARDWARE ANALYSIS RESULTS lVertical ... e- Governing Load Combo DL ILL SL W E Total D+.6W 0lbs — — --- — 0lbs Governing Load Combo DL LL SL W E Total D+.6W 0lbs --- --- 37.4lbs — 371bs Withdrawal Load W = 37 Ibs Shear Load Z = 0 Ibs Load Duration Factor Co = 1.60 W' = 688 Ibs Z' = 259 Ibs a = 90.00 p = 2.50 in. R = 37 Ibs Z'Q = 688 Ibs i' R ---� 105 Pass I Z