Loading...
HomeMy WebLinkAbout51638-Z Of SOUryo!° Town of Southold * * P.O. Box 1179 �0 53095 Main Rd umv. Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 46119 Date: 04/17/2025 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 16465 New Suffolk Ave New Suffolk, NY 11956 Sec/Block/Lot: 117.-6-32.1 Conforms substantially to the Application for Building Permit heretofore,filed in this office dated: 12/20/2024 Pursuant to which Building Permit No. 51638 and dated: 02/12/2025 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: Roof mounted solar on existing single-family dwelling as applied for. The certificate is issued to: David Frankel Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: 51638 4/4/2025 PLUMBERS CERTIFICATION: 4utho -ad Signat e of Sao T TOWN OF SOUTHOLD BUILDING DEPARTMENT `� • TOWN CLERK'S OFFICE cauffm SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 51638 Date: 02/12/2025 Permission is hereby granted to: David S Frankel 68 Bradhurst Ave Ph N New York, NY 10039 To: Install roof mount solar on existing single family dwelling as applied for. Disconnects must be located on the exterior, labeled, and readily accessible. Premises Located at: 16465 New Suffolk Ave, New Suffolk, NY 11956 SCTM# 117.-6-32.1 Pursuant to application dated 12/20/2024 and approved by the Building Inspector. To expire on 02/12/2027. Contractors: Required Inspections: Fees: CO-RESIDENTIAL $100.00 ELECTRIC -Residential $125.00 SOLAR PANELS $100.00 Total 325.00 Building Inspector tio��OF SOUTyQI Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 G • Q Southold,NY 11971-0959 'Q �y&4UNTY,�c`� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: David S Frankel Address: 16465 New Suffolk Ave City: New Suffolk St: NY Zip: 11956 Building Permit#: 51638 Section: 117 Block: 6 Lot: 32.1 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: Trinity Solar License No: 57843ME SITE DETAILS Office Use Only Indoor Basement r Service F Solar Outdoor R 1 st Floor r Pool F Spa r Renovation I—I 2nd Floor r Hot Tub I Generator F Survey Attic r Garage Battery Storage r INVENTORY Service 1 ph r Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph 1- Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures Other Equipment: 4.92kW Roof Mounted PV Solar Energy System w/ (12) Hanwha 410W Modules Notes: Solar Inspector Signature: X Date: April 4, 2025 Sean Dev Electrical Inspector sean.devlinCa_town.southold.ny.us 1.6465NewS uffo IkSolar fif so TOWN OF SOUTHOLD BUILDING DEPT. cou ,N 631-765-1802 I NSPECTION [ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [�NAL &01, i [. ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) j ] -ELECTRICAL (FINAL) [ . ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: O� �/t dk. DATE Lam INSPECTOR. ho��OE 50UTyOlo s l b (./ I v ICJ P1 /�j # # TOWN OF:SOUTHOLD BUILDING DEPT. cou 631-765-1802 INSPECT[ON [ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE:& CHIMNEY : [ ] FIRE:SAFETY INSPECTION FIRE'RESISTANT CONSTRUCTION [ ]''FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [/ ] PRE C/O [ ] RENTAL REMARKS: DATE LP J INSPECTOR 51 co313 -t rTr)' n i SOLAR Southold Town, NY APR. 7 2025 March 17, 2025 Town Hall Annex Building54375 Route 25 P.O. Box 1179 Southold, NY 11971 r. RE: DAVID S FRANKEL Trinity Solar No. 16465 New Suffolk Avenue 2024-07-1126401 New Suffolk, NY 11956 To the Building Official: I hereby certify that I am a Licensed Professional Engineer in the State of New York.The solar photo-voltaic(PV)system installed at the above-referenced location conforms to the manufacturers'requirements/specifications.The PV system complies with all applicable laws, codes and ordinances as specified by all applicable codes, including 2020 Residential Code of New York State and the 2018 IRC, and the provisions of ASCE7-16. Regards, Ayracon Almaraz, PE Structural Engineer-Trinity Solar Of NE Jy y V. 4 O,p� 100315 AROFESS10Na� NY License No:100315,expiration date:12/31/2026 Trinity Solar 2180 5th Avenue,Unit 1 Ronkonkoma,NY 1(631)319-7233 FIELD INSPECTION REPORT DATE COMMENTS FOUNDATION (1ST) ---- - ----- ,� ------ ------ cz � C FOUNDATION (2ND) j z — o ROUGH FRAMING& - Z� PLUMBING - INSULATION PER N.Y. STATE ENERGY CODEEle - • �C' os /its / C.�2fi' c '� 2�,��frL -4�_ �/J FINAL .a OK� •Q• � �j( �(GG _ ADDITIONAL COMMENTS ' _'I 2 �bc3{' 1 Yl b-1Zi��/ �QiG✓ a'K O -- o _ x --- x - b gpFF01K =cos coGy TOWN OF SOUTHOLD—BUILDING DEPARTMENT y Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 �y�ol ao� Telephone (631) 765-1802 Fax (631) 765-9502 https://www.southoldtownny.gov Date Received APPLICATION FOR BUILDING PERMIT Pr'71 ter For Office Use Only r) ��t�,f y .�` PERMIT NO. i� Building Inspector: • .. _ ! W ..a DEC 2 0 2024: Applications and forms must be filled out in their entirety.Incomplete applications will not be accepted. Where the Applicant is not the owner,an '��^^����('t+,rqq� ,,,�,. R 77,i s!L7L_t.7'r�rF ..4 Owner's Authorization form(Page 2)shall be completed. Al . _ Date:11/25/2024 OWNER(S)OF-PROPERTY: Name:David Frankel SCTM#1000-117.00-06.00-032.001 Project Address:16465 New Suffolk Ave. New Suffolk, NY 11956 Phone#:631-734-4135 Email:davidfrankeleditor@.gmail.com Mailing Address:6465 New Suffolk Ave. New Suffolk, NY 11956 CONTACT PERSON: Name7rinity Solar- Samuel Magliaro - Mailing Address:2180 5th Ave Unit 1 , Ronkonkoma, NY 11779 Phone#:631-319-7233 Emailtrittany�gaumer@trinity-solar.com DESIGN PROFESSIONAL-INFORMATION: Name:Trinity Solar- ,. racon V Almaraz Mailing Address:2211 Allenwood Rd. Wall, NJ 07719 Phone#:-(631)319-7233 Email:Ayracon.Almaraz@trinity-solar.com CO NTRACTO R.,I N FORMATION: Name:Trinity Solar- Samuel Magliaro Mailing Address:2180 5th Ave Unit 1A, Ronkonkoma, NY 11779 Phone#:(631)319-7233 Emailtrittany_gaumer@trinity-solar.com DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ®Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: ❑Other' $21,465.79 'Will the lot be re-graded? Dyes ONO Will excess fill be removed from premises? ❑Yes ❑No • 1 PROPERTY INFORMATION Existing use of property: Intended use of property:SOlar PaCle�$ Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property?..❑Yes ❑No IF YES, PROVIDE A COPY. ❑Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code.,APPLICATION IS HEREBY MADE to the Building Department for the Issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized Inspectors on premises and In building(s)for necessary Inspections.False statements made herein are punishable as a Class Amisdemeanor pursuant,toSection 210.45 of the New York State Penal Law. Application Submitted By(print na );Trinity Solar- Samuel Magllar0 BAuthorized Agent ❑Owner• Signature of Applicant: Date: I STATE OF NEW YORK) SS: COUNTY OF S SGM 7 being duly sworn,deposes and says that(s)he is the applicant (Name of individual signin ontract)above named, (S)heisthe /4 (Contractor,Agent,Corpo to Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of.his/her knowledge and,belief;and that the work will be performed in the manner set forth in the application file therewith. -Sworn before me this l� day of 20 0� Not Pu is SARAH YARBROUGH NOTARY PUBLIC-STATE OF NEW Y RK 55 PROPERTY OWNER AUTHORIZATION No.07 Suffolk Co Qualified in Suffolk County (Where the applicant is not the owner) My Commission Expires 09-2640 6 ,, David Frankel residing at 6465 New Suffolk'Ave. New Suffolk, NY 11956 � do hereby authorize Trinity Solar- Samuel Magliaroto apply on my behalf to the Town of Southold Building Department for approval as described herein. lii s. �XX 12- 19 r21-P Owner's Signature Date �Q,yid Franl�,el Print Owner's Name 2 OSVffp� �' BUILDING DEPARTMENT- Electrical Inspector CG TOWN OF SOUTHOLD Town Hall Annex - 54375 Main Road - PO Box 1179 y Southold, New York 11971-0959 ems' Telephone (631) 765-1802 - FAX (631) 765-9502 •��,., 4�,�,,,;,.t roge rr(cD south oldtownny,,aov —.sea nd OD-so utholdtown ny.-gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Company Name: Trinity Solar Name: Richard Guarneri License No.: ME-57843 email: Rich.guarneri@trinity-solar.com Address: 2180 5th Ave Unit 1A, Ronkonkoma, NY 11779 Phone No.: (631)319-7233 JOB SITE INFORMATION (All Information Required) Name: David Frankel Address: 6465 New Suffolk Ave. New Suffolk, NY 11956 Cross Street: New Suffolk Road Phone No.: 631-734-4135 BIdg.Permit#: 5 1 (0 52r email: davidfrankeleditor mail.com Tax Map District: 1000 Section: 117.00 Block: 06.00 Lot: 032.001 BRIEF DESCRIPTION OF WORK (Please Print Clearly) Installation of a utility approved,grid inter-tied,flush mount,roof mounted,12 Hanwha 410 solar panels,4.92kW photovoltaic electricity generating system. Construction Cost:$21,465.79 Circle All That Apply: Is job ready for inspection?: YES / NO Rough In Final Do you need a Temp Certificate?: r YES / NO Issued On Temp Information: (All information required) Service Size 1 Ph 3 Ph Size: A #Meters Old Meter# New Service- Fire Reconnect- Flood Reconnect- Service Reconnected - Underground - Overhead # Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION ' Request for Inspection Form.xis PERMIT# Address: Switches Outlets GFI's Surface Sconces H H's UC Lts Fridge HW POOL Fans Mini Fr. W/D PanelPump Exhaust Oven Sump Heater Trnsfmr Smokes DW Generator Salt Gen. Carbon Micro GrbDis Water BondLights Heat Pucks ERV HOT TUB/SPA Inst Hot DeHum Transfer Disc Combo Cooktop Minisplit Blower AC AH Hood Blower Service Amps Have Used Sub Amps Have Used Comments NIOIF LAND OF S yAfS 06' 99,99, NVOIF 0.7 J t". 0 Zee O'lcc OU/S DeA,fA R 7-INI LOIS DeAM R 7-INI L/ 23,386 SO. F7. S'a /o. OO E' Ise 8.00, - c d> 0.2 of /C .4�WJE.S:f 0 . N w 09 207.09, to 108.59. IVIOIFJOHN& C\l ►ERTRUOE HARTUNG 18,844SQ, FT 18,319 SO. FT 6 o CO /7.4 CO JVC �IF LAND,Oc f IKEN ICDONNELL & y FOL OUGHNEY CIE 9q.06' s/-,e *0 N 84, 0, 00. S, W. 192-56' NE► SUFFO� AVENUE , le 1-4ao V ®o® EcoFasten. ® For Installers. By Installers. 1 COMPLETE RAIL-BASED RACKING SYSTEM ClickFit is one of the fastest installing rail-based systems in the industry. Thanks to its Click-in rail assembly, the / :: Composition Shingle, Tile,Metal rails can be connected to any of EcoFasten's composition shingle, tile, and metal roof mounts in seconds without the need for fasteners or tools. The ClickFit system is f� made of robust materials such as aluminum and coated :::: ;` mmmm Rail-Based steel, to ensure corrosion-resistance and longevity. ClickFit conforms to UL 2703 and has been tested in extreme weather conditions including wind,fire, and snow. Structural-Attach FEATURES & BENEFITS Direct-Attach I • Tool-less,fastener-free rail attachment • Fully integrated bonding • Click-On Mid&End Clamps • Compatible with a variety of EcoFasten roof attachments !° 11 YEAR WARRANTY FAST INSTALLING SYSTEM FEATURING _ 4 o , o CLICK—IN RAIL ASSEMBLY FIT INTERNAL SPLICE Tool-free bonded internal Splice installs in seconds. MLPE MOUNT Attach Module Level Power MID CLAMP Electronics to the top of the rail. Click-on mid clamp features integrated ` bonding pins and fits modules 30-50 m m in width. END CLAMP Click-on end clamp fits modules END C A P 30-50mm in width. The slide-on end caps allow the end clamps to be accurately positioned on the rail in seconds, while providing an aesthetically- pleasing, finished install. L- FOOT f The ClickFit rail simply clicks tf' into our proprietary composition x- shingle & the L-foot without the need to use fasteners or tools. ' i i J ' COMPOSITION SHINGLE Combine the versatile ClickFit L-Foot with the watertight GF-1 flashing for a fast installation on composition shingle roofs. GF-t FLASHING&L-FOOT TILE ROOFS Use the adjustable ClickFit Tile Hook for attaching the ClickFit system to the roofs.Works with ., Flat, S, and W the profiles. IS i-r r,/'• CLICKFIT TILE HOOK STANDING S EAM METAL ROOFS _ _ Combine the ClickFit L-Foot s with SimpleBlock°-U for a i fast installation on standing seam metal roofs. SIMPLEBLOCK-U -- � FIT PRODUCT PART PART BOX =QPALTEIT IMAGENUMBER DESCRIPTION QUANTITY ASSEMBLED WITH(1)GF GROMMET AND INCLUDES(1)5/16"EPUM BONDED WASHER - GF1M GAL BLK 810 GF18X10"BLKMT 50 3200 W/2"HL PLCMT - GF7 GAL BLK 812 GF7 8X12"GALVALUME BLK 50 2600 FLASHING HARDWAREALL , , OO 1500004 CF L-FOOT 100 5000 (NO HARDWARE NEEDED) 1500005 CF TILE HOOK US 20 480 1510045 CF TILE HOOK SUB-FLASHING 20 2160 TILE HOOK FLSH F ST TILE HOOK FLASH 12 576 FLAT SIERRA TAN TILE HOOK FLSH-W ST TILE HOOK FLASH 12 576 W SIERRA TAN TILE HOOK FLSH-S ST TILE HOOK FLASH 12 576 S SIERRA TAN SIMPLEBLOCK-U-AL 2"SIMPLEBLOCK SSR-AL 25 4400 ALL HARDWARE INCLUDED WITH OO 1500004 CF L-FOOT ASSY 50 5000 I (NO HARDWARE NEEDED) I .�i 1500033 CF RAIL 21(_7F N/A 108 n 1500034 CF RAIL4 FT) N/A 108 (-10. FT) OF RAIL 8 FT) 1500035 ( IL420 N/A 108 1008051 CF RAIL SPLICE 100 3200 r ` 1510070 CF WIRE MGMT CLIP 1000 TBO 150002E MODULE JUMPER,8IN 25 25000 3d (204MMI �� 1510057 CF MLPE MOUNT 400 17600 r a� PRODUCT PART PART BOX PALLET IMAGE NUMBER DESCRIPTION LQUANTITY QUANTITY 1510041 CF ENOCAP,BLK LABELED 100 4900 1510015 CF HO ENDCLAMP 20 5600 30MM,BLK 1510016 CF HO ENDCLAMP 50 5600 32MM,BLK 1510017 CF HD ENDCLAMP 50 5600 35MM,BLK 151001B CF HO ENDCLAMP 50 5600 38MM,BLK 1510019 CF HO ENDCLAMP 50 5600 40MM,BLK 1510020 CF HO ENDCLAMP 50 5600 45MM,BLK 1510011 CF HO MIOCLAMP 50 5600 j 30-40MM,BLK 1510012 CF HO MIOCLAMP 50 5600 i 40-50MM,BLK ROCK-IT V3 SKIRT A65 35MMMM&&R SKIRT V3 40MM 65" 8 255 ROCK IT V3 SKIRT A79 ROCK IT SKIRT 79 6 256 35MM&40MM 79" ROCK IT V3 SKIRT ABO ROCK IT SKIRT V3 8 256 35MM&40MM 80" ROCK IT V3 SKIRT B65 ROCK IT SKIRT V3 8 256 32MM&38MM 65" ROCK IT V3 SKIRT B79 ROCK IT SKIRT79 8 256 32MM&38MM 79" ROCK IT V3 SKIRT B80 ROCK I7 SKIRT3 8 256 38MM 8 32MM&38MM 0 1500003 CF UNIVERSAL SKIRT 50 5750 CLAMP BLK POLY KIT LAS SCREW 4 POLY KIT LAG 50 480 SCREW 4"(501 SCRW OP 15-13XC3 ROOFING SCRW 1000 60000 #15 X 3"DRILL PT INCLUDESBOLT AND 1510001 CONOUITMOUNT-BRKT 50 10350 jl CONOUITMOUNT-TILE CONDUIT MOUNT-TILE SYSTEM 60 4320 7CL ICKFIT I EWA Nol �• \ s i;�.F � � \\ �\�\�\\` \\� �\ � ♦ t ,(>\ •.fir` w .. -�-�.. ~° .. k � t. �� K * t" ti ~;��A \`\\• \\`' ��r , cr i s 4s 0", � k, g4, x,N,.�''' x,w1�Z!x„�C�T�. \ - R�" ,�%�• � '� _ � . g�v'° Aw`i�` et,� ^'' i!(' ii:.�.�s•4 \,. Fw�� P�l; ����.Sit�i•� �'`�: I °{ .�:,�7s w�,;;,.E' .;n..?M�' �� ��;61'��±�'� .�a��x � 4. "�c;.,+��`�.{+ F- i 1�T�h"� 5� ,its, > 'G',.. .',� f ":� ;4�YN��_ F �~�������';.4�.`R�'°$:tr�l. �A''•. Nr '�'-t"a�,�1: ,���;', S''.+•_trta, .r `�; <•y��ak���,u.,z'�"�,3�Fi,���'EL�4c. > t.��Y,..�$,r.„ ���i,�` `'Q `A,k,"'�,it��'"'' '� friy:>��'C,� ��;F'"__�"�{'=�'3 t�iL `j. j,� ��.` tf�. ,��aSw�t-X�t ' :'�'.;?�vx��,,^�`�E'n•���.,, �' 'S8`Tt"�3� 4it ���nti^s�:^> .��'."k'�'K�`}�{, '>`�.^.:.�� r �'�H S ,s.,X.. _s: ,nr ''�-:ge.�'- �.ern .:�».�.. sA�.•v.„�'3c.:i ,,.x, ,.�k \.,a����t��n",,;. t?.�t{',�s,....��.%fi ..tc.„•rab....x..�_.�,�,. ��'fie.�':5�"�.. �'���"� • IL November 22,2024 SOLAR y Trinity Solar No.2024-07-1126401 Southold Town,NY RE:DAVID S FRANKEL Town Hall Annex Building54375 Route 25 P.O.Box 1179 16465 New Suffolk Avenue Southold,NY 11971 New Suffolk,NY 11956 To the Building Official: The following information constitutes a summary of the relevant design criteria and recommendations for the support of a new photovoltaic(PV)system on the existing roof framing components at the above-referenced location.Trinity Solar,LLC has confirmed this structure is permitted by the local jurisdiction and has provided all relevant documentation regarding the existing structure.As of the date of this evaluation,no concerns nor deficiencies related to the existing structure have been reported.Therefore,this assessment is based on the premise the existing structure is in good condition and capable of supporting the existing loads.This evaluation is strictly limited to the support of the PV system and does not extend to any other structural elements not directly involved in the solar panel installation.If any discrepancies from the actual conditions are identified,or if concerns regarding the existing structure arise,this office must be notified prior to proceeding with the installation.All spans listed below are horizontal projections. 1.Existing Roof Framing: •Conventional roof framing at R3:2X6 at 24 o.c.;existing rafter span is the max unsupported span=1 V-2" 2.Roof Loading: •3.00psf-New PV array load(PV panels,mounting rails,and hardware) •4.49psf-Existing roof dead load(0.98psf-2X6 at 24"o.c.roof rafters,3.51 psf-roof covering) •20psf-Ground snow load -per AHJ(Authority Having Jurisdiction) •Exposure Category C,130mph design wind speed 3.Existing Roof Modification: •R3-No modification required.Existing roof framing is acceptable for PV installation. 4.Attachments: •The maximum allowable spacing of the ECOFASTEN-SMART FOOT*attachments can't exceed more than 48".Attachments to be fastened using quantity (2)#14 x 3"Structural Screws for a rail system or#12 x 3"for rail-less system with a minimum penetration depth of 2.5"-this is adequate to resist all stated demand loads above.Install attachments,rails,and panels per manufacturer requirements.Stagger attachments to distribute load. *ATTACHMENT TO BE SECURED TO RAFTERS NO LESS THAN 2x4 IN SIZE.ONLY INSTALL ATTACHMENT ON ASPHALT SHINGLE ROOFS OF SLOPES GREATER THAN 2:12-OR-9.46°WITH A MINIMUM 7/16"DECK.CONTRACTOR TO INFORM THIS OFFICE IF ANY ITEM ABOVE DIFFERS FROM SITE CONDITIONS. The installation,described above,is in general conformance with the manufacturers'specifications and complies with all applicable laws,codes,and ordinances as specified by applicable codes,including the 2020 Residential Code of New York State and ASCE 7-16. It should be noted that only PV-supported roofs are reviewed.Trinity Solar is not responsible for any construction flaws or defects that may currently exist in areas of the structure that are not directly related to the PV installation. Regards, Ayracon Almaraz,PE Structural Engineer-Trinity Solar OF NE PI y V. 100315 A'QOFESSIONa� License No.100315,expiration date:12/31/2026 Trinity Solar 12180 5th Avenue,Unit 1 1 Ronkonkoma,NY 1(631)319-7233 Single Phase Inverter with HD-Wave Technology for North America F SE3OOOH-US / SE38OOH-US / SE5O0OH-US / SE6O0OH-US / SE76OOH-US / SE10OOOH-US / SE1140OH-US '..'..' 12-25 EAR WAR )N LA i I i ® solar=,- �., ,m, ® ® aolarZ-=L _4D_. j 0 t t { i Optimized installation with HD-Wave technology / Specifically designed to work with / UL1741 SA certified,for CPUC Rule 21 grid compliance power optimizers / Record-breaking efficiency / Extremely small / Quick and easy inverter commissioning directly from a smartphone using the SolarEdge SetApp ® Built-in module-level monitoring / Fixed voltage inverter for longer strings / Outdoor and indoor installation / Integrated arc fault protection and rapid shutdown for NEC 2014 and 2017, per article / Optional: Revenue grade data,ANSI C12.20 690.11 and 690.12 Class 0.5 (0.5%accuracy) solaredge.com solar ® Single Phase Inverter Wit HD-Wave Tec nology for North America SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US/ SE760OH-US / SE10000H-US / SE1140OH-US APPLICABLE TO INVERTERS WITH PART NUMBER SEXXXXH-XXXXXBXX4 OUTPUT Rated AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 11400 @ 240V VA 3300 @ 208V 5000 @ 208V 10000 @ 208V Maximum AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 11400 @ 240V VA 3300 @ 208V 5000 @ 208V 10000 @ 208V AC Output Voltage Min.-Nom.-Max. ✓ ✓ ✓ ✓ ✓ ✓ ✓ Vac (211-240-264) AC Output Voltage Min.-Nom.-Max. ✓ ✓ ✓ Vac (183-208-229) AC Frequency(Nominal) 59.3-60-60.50) Hz Maximum Continuous Output 12.5 16 21 25 32 42 47.5 A Current @240V Maximum Continuous Output _ 16 - 24 - - 48.5 A Current @208V Power Factor 1,adjustable-0.85 to 0.8S GFDI Threshold 1 A Utility Monitoring,Islanding Protection,Country Configurable Yes Thresholds ;INPUT l Maximum DC Power @240V 4650 5900 7750 9300 11800 15S00 17650 W Maximum DC Power @208V 5100 7750 15500 W Transformer-less,Ungrounded Yes Maximum Input Voltage 480 Vdc Nominal DC Input Voltage 380 400 Vdc Maximum Input Current @240VP 8.5 10.5 13.S 16.5 20 27 30.5 Adc Maximum Input Current @208Vt=1 - 9 13.5 27 Adc Max.Input Short Circuit Current 45 Adc Reverse-Polarity Protection Yes Ground-Fault Isolation Detection 600ko Sensitivity Maximum Inverter Efficiency 99 99.2 % CEC Weighted Efficiency 99 99 @ 240V % 98.5 @ 208V Nighttime Power Consumption <2.5 W m For other regional settings please contact SclarEdge support 'n A higher current source may be used;the inverter will limit its input current to the values stated r ® Sin le Phase Inverter Wit HD-Wave Technology for North America SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US/ SE760OH-US / SE10000H-US / SE1140OH-US ADDITIONAL FEATURES Supported Communication Interfaces RS485,Ethernet,ZigBee(optional),Cellular(optional) Revenue Grade Data,ANSI C12.20 Optionalt3l Inverter Commissioning with the SetApp mobile application using built-in Wi-Fi Access Point for local connection Rapid Shutdown-NEC 2014 and Automatic Rapid Shutdown upon AC Grid Disconnect 2017 690.12 "STANDARD COMPLIANCE I Safety 1-11-1741,UL1741 SA,UL16998,CSA C22.2,Canadian AFCI according to T.I.L.M-07 Grid Connection Standards IEEE1547,Rule 21,Rule 14(HI) Emissions FCC Part 15 Class B ,INSTALLATION SPECIFICATIONS AC Output Conduit Size/AWG 1"Maximum/14-6 AWG 1"Maximum/14-4 AWG Range DC Input Conduit Size/#of Strings/ 1"Maximum/1-2 strings/14-6 AWG 1"Maximum/1-3 strings/14-6 AWG AWG Range Dimensions with Safety Switch 17.7 x 14.6 x 6.8 /450 x 370 x 174 21.3 x 14.6 x 7.3/540 x 370 x 185 In/ (HxWxD) mm Weight with Safety Switch 22/10 25.1/11.4 1 26.2/11.9 38.8/17.6 lb/kg Noise <25 <50 dBA Cooling Natural Convection Operating Temperature Range -40 to+140/-40 to+60(4) F/-C Protection Rating NEMA 4X(Inverter with Safety Switch) *Revenue grade inverter P/N:SExxxxH-US000BNC4 to Full power up to at least 50'C/122'F,,for power de-rating information refer to:https://www.solaredge.com/sites/default/files/se-temperature-derating-note-na.pdf m SolarEdge Technologies,Inc.All rights reserved.SOLAREDGE,the SolarEdge logo,OPTIMIZED BV SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies,Inc All Ro H S other trademarks mentioned herein are trademarks of their respective owners.Dale:52019N01/ENG NAM.subject to change without notice. OPEAK DUO BLK IVIL-G10+ SERIES Qce11s 385-410 Wp 1132 Cel Is 20.9% Maximum Module Efficiency MODEL O.PEAK DUO BLK ML-G10+ Breaking the 20%efficiency barrier 111r,111111I111I11ILIl1L Q.ANTUM DUO Z Technology with zero gap cell layout boosts module efficiency up to 20.9%. A reliable investment Rn Inclusive 25-year product warranty and 25-year linear Warranty performance warranty'. Enduring high performance �Vf Long-term yield security with Anti LeTID Technology, cells Anti PID Technology2 and Hot-Spot Protect. Extreme weather rating CP High-tech aluminium alloy frame,certified for high snow(5400 Pa)and wind loads(4000 Pa). Innovative all-weather technology - Optimal yields,whatever the weather with excellent low-light and temperature behaviour. 6 busbar 12 busbar cell technology cell technology n The most thorough testing programme in the industry Qcells is the first solar module manufacturer to pass the most comprehensive quality programme in the industry:The new"Quality Controlled PV"of the independent certification Institute TUV Rheinland. 'See data sheet on rear for further information. 'APT test conditions according to IEC/TS 628044:2015,metnod A(-1500V,96h) The ideal solution for: c�vm�ew 1 ` 2023 Rooftop arrays on T1°"^° JE�c+ a zozz ° ° residential buildings USA °° OPEAK DUO BLK ML-G10+ SERIES ■Mechanical Specification )4a'hal9 mml Format 74.0in x 4111n x 1.26In(including frame) ,2.a'ageamml ,56'p955 mm1 (1879 mm x 1045mm x 32 mm) Weight 48.5lbs(22.0kg) Front Cover 0.13 in(3.2 mm)thermally pre-stressed glass < ­mon9PannPa,ansmml 149 3a,•„' with anti-reflection technology °2•p9amml Back Cover Composite film ® „ aow mml Frame Black anodised aluminium Cell 6 x 22 monocrystalline Q.ANTUM solar half cells a -E] 2.92•r2somml Junction box 2.09-3.981n x 1.26-2.36in x 0.59-0.71 in (53-101mm x 32-60mm x 15-18mm).IP67,Wth bypass diodes e•pmneBenolea cv,N90°n mEuwa Cable 4mm'Solar cable;(+)a49.21n(1250mm),(-)a49.21n(1250mm) t 2a•p2 mm) n I Connector Staubli MCA;IP68 oas p4smm1 T-�I03rla.smml ■Electrical Characteristics POWER CLASS 385 390 395 400 405 410 MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS,STCI(POWER TOLERANCE+5 W/-O W) Power at MPP' P.- PM 385 390 395 400 405 410 E Short Circuit Current' Isc [A] 11.04 11.07 11.10 11.14 11.17 11.20 Open Circuit Voltage' Voc [V] 45.19 45.23 45.27 45.30 45.34 45.37 5 Current at MPP IH [A] 10.59 10.65 10.71 10.77 10.83 10.89 2 Voltage at MPP VM [V] 36.36 36.62 36.88 37.13 37.39 3764 Efficiency' ri [%] a19.6 a19.9 a20.1 2!20.4 a20.6 2:20.9 MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS,NMOT2 Power at MPP P.- [W] 288.8 292.6 296.3 300.1 303.8 307.6 Short Circuit Current Isc [A] 8.90 8.92 8.95 8.97 9.00 9.03 c Open Circuit Voltage Vpc [V] 42.62 42.65 42.69 42.72 42.76 42.79 Current at MPP I PP [A] 8.35 8.41 8.46 8.51 8.57 8.62 Voltage at MPP Vw„ [V] 34.59 34.81 35.03 35.25 35.46 35.6E 'Measurement tolerances P_±3%;Isc;Voc±S%at STC:1000 W/m2,25±2°C,AM 1.5 according to IEC 60904-3•2800 W/m2,NMOT,spectrum AM 1.5 Ocells PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE too - no _? ••• At least 98%of nominal power as°.w•,e•aQe,ePme,�• w during first year.Thereafter max. o ss - ------------------ 0.5%degradation per year.At __ w n least 93.5%of nominal power 0 lao --+----- ------- a up to 10 years.Al least 86%of zo nominal power up to 25 years. u,z es g All data within measurement s so w o es a tolerances.Full warranties In 3 a a accordance with the warranty w$ eo terms of the Qcells sales ad 4 a o 0 0s to IS 20 2s organisation of your respective 200 400 am eoo reae �J YEARS country. IRRADIANCE IV(%mj 'Standard terms of guarantee for the 5 Pv companies with the Typical module performance under low irradiance conditions in rvol highest production capacity in 2021(February 2021) comparison to STC conditions(25'C,1000 W/m[). TEMPERATURE COEFFICIENTS 7 Temperature Coefficient of I5G a [%/K] +0.04 Temperature Coefficient of Voc 0 [%/K] -0.27 S f%/ -0.34 Nominal Module Operating Temperature NMOT °F]Temperature Coefficient of PuP 109±54 y V (43±3°C) ■Properties for System Design Maximum System Voltage Vsys [V] 1000(IEC)/1000(UL) PV module classification Class 11 a Maximum Series Fuse Rating [A DC] 20 Fire Rating based on ANSI/UL 61730 TYPE 2 0 Max.Design Load,Push/Pull' [Ibs/ft2] 75(3600Pa)/55(2660Pa) Permitted Module Temperature -40°F up to+185°F Max.Test Load,Push/Pull' [Ibs/ft'] 113(5400Pa)/84(4000Pa) on Continuous Duty (-40°C up 10+85°C) eo2 3 See Installation ManualZf - ■Qualifications and Certificates _ ILL 61730,CE-compliant, Quality Controlled PV-TOV Rheinland, _ _ - .IEC 61215:2016,IEC 61730:2016, 9'. U.S.Patent No.9,893,215(solar cells)• CCE � _ qLe�aq ,oii uwn) 0 0 Ocells pursues minimizing paper output in consideration of the global environment. Note:Installation instructions must be followed.Contact our technical service for further information on approved installation pf this product ���'I Hanwhd 0 CELLS Am ena)Inc.400 Spectrum Center Drive.Suite 1400.Irvine.CA 9261 S.USA I TEL+1 949 748 59 961 EMAIL hqc-inquiryatgcells.com I WEB www.g m cells.co NOTES: L)COMPLIES WITH NEC 2017 — 2.)REFER TO SHEET PV-3 FOR SITE SPECIFIC VALUES REQUIRED BY NEC 690 3.1 STICI(ERS,LABELS,AND PLACNARDS SHALL BE OF SUFFICIENT DURRABRITY TO WITHSTAND THE ENVIROMENT INVOLVED • To be and on all DC junction boxes and every Won DC conduit _ As • • • m® NEC 69031(GJ •—•• Own i ty �,S O.L AR NEC 690.S6(C)(I)(A) DGunNon Box q _ �• • Fall, 690.56(C)(3) NEC690.4(B) L4 Service Disconnect •- (^ •NEC 690.138 NEC fi9053 fi90.56(C)(3) SoUdeck 2N • • • Utility tutrwcu•mug��, r—�—� ..ate�� r • w NEC 690.4(B) , J NEC 690.13(8) �..- NEC 690.56(C)(1)(A) If System is Backted Breaker ® ! - NEC69053 NECWIWI — I NEC 690.54 DC Disconnect Utility Meter Socket ® Fiw �r® i ® • NEC690.13(0) NEC 690.54 ,r(. NEC 690.13(8) 1 L f DC Conduit Main Service Panel Solar Meter Socket Photovoltaic Load Center Inverter(s) Enphase Envoy Box AC Disconnect (To Combine Inverters) NEW SUFFOLKAVENUE• INSTALLATION OF NEW ROOF MOUNTED PV SOLAR SYSTEM - - 16465 N EW SU FFOLK AVEN U E NEW SUFFOLK NY 11956 100315 R�FfSSIONp Exp: 12/31/2026 Issued/Revisions P1 35SUED TO TOWNSHIP FOR PERMIT 11/21/2M #41■OEM VICINITY MAP SITE NO. DESCRIPTION DATE L.JSCALE: NTS Project Title: OCCUPANCYOR DAVID S FRANKEL- RETAIN STORM WATER RUNOFF USE IS UNLAWFUL TRINITY ACCi#:2024-07-1126401 T'URSUANT TO CHAPTER 236 Project Address: T!-4F TOWN CODE WITHOUT CERTIFICATE 16465 NEW SUFFOLK AVENUE OF OCCUPANCY NEW SUFFOLK,NY 11956 40.99151-72.4756 GENERAL NOTES GENERAL NOTES CONTINUED GENERAL NOTES CONTINUED ABBREVIATIONS CONTINUED SHEET INDEX Drawing Title: 1. THE INSTALLATION CONTRACTOR IS 8.. THE DC VOLTAGE FROM THE PANELS IS 14. B) CURRENT PREVAILING UTILITY JB JUNCTION BOX PV-1 COVER SHEET W/ SITE INFO & NOTES RESPONSIBLE FOR INSTALLING ALL ALWAYS PRESENT AT THE DC COMPANY SPECIFICATIONS, kCMIL THOUSAND CIRCULAR MILS EQUIPMENT AND FOLLOWING ALL DISCONNECT ENCLOSURE AND THE DC STANDARDS,AND REQUIREMENTS kVA KILO-VOLT AMPERE PV-Z ROOF PLAN W/ MODULE LOCATIONS PROPOSEDPVSOLARSYSTEM DIRECTIONS AND INSTRUCTIONS TERMINALS OF THE INVERTER DURING 15 THIS SET OF PLANS HAVE BEEN kW KILO-WATT CONTAINED IN THE DRAWING PACKAGE AND DAYLIGHT HOURS.ALL PERSONS PREPARED FOR THE PURPOSE OF kWH KILO-WATT HOUR PV-3 ELECTRICAL 3 LINE DIAGRAM INFORMATION RECEIVED FROM TRINITY. WORKING ON OR INVOLVED WITH THE MUNICIPAL AND AGENCY REVIEW AND L LINE 2. THE INSTALLATION CONTRACTOR IS PHOTOVOLTAIC SYSTEM ARE WARNED APPROVAL.ONCE APPROVED,THE NICE! MAIN CIRCUIT BREAKER AP APPENDIX Drawing Information RESPONSIBLE FOR INSTALLING ALL THAT THE SOLAR MODULES ARE INSTALLATION CONTRACTOR IS MOP MAIN DISTRIBUTION PANEL DRAWING DATE: il/21/2024 EQUIPMENT AND FOLLOWING ALL ENERGIZED WHENEVER THEY ARE RESPONSIBLE FOR INSTALLING ALL MLO MAIN LUG ONLY DIRECTIONS AND INSTRUCTION CONTAINED EXPOSED TO LIGHT. SYSTEM COMPONENTS AS DESCRIBED IN MTD MOUNTED -- DRAWN BY: KTD IN THE COMPLETE MANUAL. 9. ALL PORTIONS OF THIS SOLAR THE DRAWING PACKAGE. MTG MOUNTING wM ISED BY: - 3. THE INSTALLATION CONTRACTOR IS PHOTOVOLTAIC SYSTEM SHALL BE 16 ALL INFORMATION SHOWN MUST BE N NEUTRAL APPROVED AS NOTED COMPLY WITH ALL CODES RESPONSIBLE FOR READING AND MARKED CLEARLY IN ACCORDANCE WITH CERTIFIED PRIOR TO USE FOR NEC NATIONAL ELECTRICAL CODE UNDERSTANDING ALL DRAWINGS, THE NATIONAL ELECTRICAL CODE CONSTRUCTION ACTIVITIES. NIC NO# NUM IN BER ER CONTRACT f1w ./a-a S e,P.# (� NEW YORK STATE &I�WN O @ .Information: COMPONENT AND INVERTER MANUALS ARTICLE 690 705. NTS NOT TO SCALE YA AS REQUIRED AND CatVDITt JT SIZE: 4.92kW PRIOR TO INSTALLATION.THE INSTALLATION 10. PRIOR TO THE INSTALLATION OF THIS CONTRACTOR IS ALSO REQUIRED TO HAVE PHOTOVOLTAIC SYSTEM,THE OCP OVER CURRENT PROTECTION AC SYSTEM SIZE: 3.8kW ALL COMPONENT SWITCHES IN THE OFF INSTALLATION CONTRACTOR SHALL ABBREVIATIONS P POLE WWW Y ��.�1 PB PULL BOX � �� ,� B i' i�n MODULE COUNT: 12 POSITION AND FUSES REMOVED PRIOR TO ATTEND A PRE-INSTALLTION MEETING AMP AMPERERM, MO U USED: HANWHA 410 THE INSTALLATION OF ALL FUSE BEARING FOR THE REVIEW OF THE INSTALLATION AC ALTERNATING CURRENT PH 0 PHASE NOTIFY BUILDING DEPARTMENT AT (� �yy��,,yypryr�ry' Q Illl SYSTEM COMPONENTS. PROCEDURES,SCHEDULES,SAFETY AND . AL ALUMINUM PVC PWR POWER CHLORIDE CONDUIT 64.1_765-1802 8AM TO 4PM FOR THE $QU If11A�/•v' I� ECM Q.PEAK DUO BLK ML-G10+410 4. ONCE THE PHOTOVOLTAIC MODULES ARE COORDINATION. AF _AMP.FRAME �A��p��� ILITY COMPANY: PSEG-U MOUNTED,THE INSTALLATION 11. PRIOR TO THE SYSTEM START UP THE AFF ABOVE FINISHED FLOOR CITY QUANTITY FOLLOWING INSPECTIONS: SWIM,y1r1'IilY�7 ILITY ACCT#: CONTRACTOR SHOULD HAVE A MINIMUM OF INSTALLATION CONTRACTOR SHALL AFG ABOVE FINISHED GRADE RGS RIGID GALVANIZED STEEL UTILITY METER#: ONE ELECTRICIAN WHO HAS ATTENDED A ASSIST IN PERFORMING ALL INITIAL AWG AMERICAN WIRE GAUGE SN SOLID NEUTRAL 1, FOUNDATION-TWO REQUIRED �/� SOLAR PHOTOVOLTAIC INSTALLATION HARDWARE CHECKS AND DC WIRING C CONDUIT (GENERIC TERM OF JSWBD SWITCHBOARD HAS DEALTYPE: SUNNOVA COURSE ON SITE. CONDUCTIVITY CHECKS. RACEWAY,PROVIDE AS TYP TYPICAL FOR POURED CONCRETE 5. FOR SAFETY,IT IS RECOMMENDED THAT 12. FOR THE PROPER MAINTENANCE AND SPECIFIED) U.0.1. _UNLESS OTHERWISE INDICATED THE INSTALLATION CREW ALWAYS HAVE A ISOLATION OF THE INVERTERS REFER TO CB COMBINER BOX WP WEATHERPROOF 2. R(.)i%]H-FRAMING &PLUMBING MINIMUM OF TWO PERSONS WORKING THE ISOLATION PROCEDURES IN THE CKT. CIRCUIT XFMR TRANSFORMER Rev.No. Sheet TOGETHER AND THAT EACH OF THE OPERATION MANUAL. CT CURRENT TRANSFORMER +72 MOUNT 72INCHES TO BOTTOM `�' INJULATIOIv - INSTALLATION CREW MEMBERS BE TRAINED 13. THE LOCATION OF PROPOSED ELECTRIC CU COPPER OF ABOVE FINISHED FLOOR OR 4. FINAL-CONSTRUCTION MUST _ _ IN FIRST AID AND CPR. AND TELEPHONE UTILITIES ARE SUBJECT DC DIRECT CURRENT GRADE P 1 1 6. THIS SOLAR PHOTOVOLTAIC SYSTEM IS TO TO FINAL APPROVAL OF THE DISC DISCONNECT SWITCH BE COMPLETE FOR C.O. P+ • U BE INSTALLED FOLLOWING THE APPROPRIATE UTILITY COMPANIES AND DWG DRAWING ALL CONSTRUCTION SHALL MEET THE CONVENTIONS OF THE NATIONAL OWNERS. EC ELECTRICAL SYSTEM INSTALLER ELECTRICAL CODE.ANY LOCAL CODE 14. ALL MATERIALS,WORKMANSHIP AND EMIT ELECTRICAL METALLIC TUBING REQUIREMENTS OF THE CODES OF NEW - WHICH MAY SUPERSEDE THE NEC SHALL CONSTRUCTION FOR THE SITE FS FUSIBLE SWITCH GOVERN. IMPROVEMENTS SHOWN HEREIN SHALL FU FUSE YORK STATE. NOT RESPONSIBLE FOR 7. ALL SYSTEM N IN ACCORDANCE WITH: GND GROUND S ALL D W TH COMPONENTS SYSTEM ARE TO BE BE A) CURRENT PREVAILING MUNICIPAL GFI GROUND FAULT INTERRUPTER DESIGN OR CONSTRUCTION ERRORS � "UL"LISTED.ALL EQUIPMENT WILL BE NEMA AND/OR COUNTY SPECIFICATIONS, HZ FREQUENCY (CYCLES PER 3R OUTDOOR RATED UNLESS INDOORS. STANDARDS AND REQUIREMENTS SECOND) 4" GENERAL NOTES / SOLAR IF ISSUED DRAWING IS MARKED WITH A REVISION CHARACTER OTHER THAN"A",PLEASE BE ADVISED THAT FINAL EQUIPMENT AND/OR SYSTEM CHARACTERISTICS ARE SUBJECT TO CHANGE DUE TO AVAILABLITY OF EQUIPMENT. 2211 Allenwood Road 877-786-7283 Wall,New Jersey 07719 www.Trinity-Solar.com ( NOTES:'REFER TO MODULE SPECS FOR MODULE DIMENSIONS _ 'DEPICTED MODULES MAY BE PORTRAIT OR LANDSCAPE NEW PV SOLAR MODULE,TYPICAL /ECOFASTEN-CLAMP (REFER TO EQUIPMENT SCHEDULE f' (REFER TO SPEC SHEET FOR DETAILS- FOR SPECS AND QUANTITIES) SOLAR MODULE •SOLAR MODULE O� .•�� ♦ NEW MOUNTING FOOT/ATTACHMENT-♦ POINTS,TYPICAL (REFER To ECOFASTEN RAIL ECOFASTEN SMART FOOT �5 N �/ ENGINEERING LETTER FOR SPACING (REFER TO SPEC SHEET FOR DETAILS)AND DETAILS) (REFER TO SPEC SHEET FOR DETAILS) \ tS ;^ _ 'G • �' ' NEW ECOFASTEN RAIL,TYPICAL TO BE MOUNTED PERPINDICULAR TO STRUCTURE(REFER TO ECOFASTEN EXISTING ASPHALT SHINGLES ` '»� SPECIFICATION/DATA SHEET FOR - (REFER TO ENGINEERS LETTER FOR SPECS DETAILS) NEW END CLIP,TYPICAL _ _ S y S.S.LAG BOLT APOC SEALANT (REFER TO ECOFASTEN SPECIFICATION ♦ ♦ /DATA SHEET FOR DETAILS) (REFER TO ENGINEERS LETTER FOR SPECS SOLAR MODULES SHALL NOT � EXISTING RAFTER EXCEED PEAK HEIGHT. _ NEW MID CLIP/TYPICAL (REFER TO ENGINEERS LETTER FOR SPEC4 - �Fp 100315 (REFER TO ECOFASTEN SPECIFICATION AR�FESS��N�� /DATA SHEET FOR DETAILS) []ATTACHMENT&CLIP DETAIL []PV MODULE ATTACHMENT ON ASPHALT-SHINGLE ROOF []HEIGHT FROM GROUND LEVEL TO PEAK OF ROOF SCALE:NOT TO SCALE - SCALE:NOT TO SCALE _ SCALE:NOT TO SCALE - EXp: 12/31/2026 ARRAY SCHEDULE . - Issued/Revisions BACK ■ .. P1 I5SUEDT0 TOWNSHIP FOR PERMIT 11/21/2D24 NO. DESCRIPTION DATE Project Title: ROOFS 0 DAVID S FRANKEL- � � MODULES:0. PITCH:S' R� - - TRINITY ACCT M 2024-07-1126401 ORIENTATION:354' ROOF MODULES:0 _ - J Project Address: PITCH:34° - - ORIENTATION:354'- ! - ROOF3 16465 NEW SUFFOLK AVENUE MODULES:22 - _ NEW SUFFOLK,NY 11956 PITCH:34 ORIENTATION:174 R7 40.9915,-72.4756 �• ROOF MODULES:0 ORIENTAT ION:84° RZ -- Drawing Title: ROOF MODULES:0 - PITCH:27° ORIENTATION:83° PROPOSED PV SOLAR SYSTEM ROOF MODULES:0 - - PITCH 30 - ORIENTATION:264° _ - - - -- ---- - :cc--- -- -�r ---- g Drawin Information ROOF 7" tt t _ t ,t r t to ttt tt tt tett DRAWING DATE: 11/21/2024 MODULES:0 . s:t` t t,. LL 11 PITCH:2' _�L)� { k t_t *k. "�� -� DRAWN BY: KTD ORIENTATION:354° ED REVISED BY: ROOFS - MODULES:O _ttr t t t t t 14 t t t� R4 PITCH 23" - ��e t t` t ` System Information: ORIENTATION:175° D �t - - ` _r... LL. ROOF 9 ��tt��" e _� - Lee uete DC SYSTEM SIZE: 4.92kV1 MODULES:0 R6 m AC SYSTEM SIZE: 3.8kW PITCH'23' O - ORIENTATION:355° cm MODULECOUNT: 12 -- ROOF10 MODULES:O MODULES USED: HANWHA410 PITCH:30° ✓ MODULE SPEC#: Q.PEAK DUO BLK ML-G10+410 ORIENTATION:263° UTILITY COMPANY: PSEG-LI ROOF 11 - UTILITYACCT#: MODULES:0 -PITCH:2* NOTES: UTILITY METER#: _ ORIENTATION:84' 1.)ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE DEALTYPE: SUNNOVA ROOF 12 WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. _ MODULES:0 2.) ARRAY BONDING TO COMPLY WITH MANUFACTURER SPECIFICATION. PITCH:18' 3.)ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. FRONT ORIENTATION:173° - Rev.No. Sheet '4) AN AC DISCONNECT SHALL BE GROUPED WITH INVERTER(S) NEC 690.13(q ROOF 13 5.) ALL OUTDOOR EQUIPMENT SHALL BE RAIN TIGHT WITH MINIMUM NEMA 3R RATING. MODULES:0 'PITCH:34' 6.) ROOFTOP SOLAR INSTALLATION ONLY PV ARRAY SHALL NOT EXTEND BEYOND THE EXISTING ROOF EDGE., ^w �` , ^ - N 1 V 1 ORIENTATION:84° - - ROOF 14 SYMBOL LEGEND PLUMBING SCHEDULE EQUIPMENT SCHEDULE MODULES:0 CITY SPEC# PITCH:34° INDICATES ROOF DESIGNATION.REFER TO INDICATES NEW UNFUSED PV DISCONNECT TO BE INDICATES NEW PV ONLY SUBPANEL ORIENTATION:264' R1 ARRAY SCHEDULE FOR MORE INFORMATION UD INSTALLED OUTSIDE (UTILITY ACCESSIBLE) SP TO BE INSTALLED 12 HANWHA 410(Q.PEAK DUO BLK ML-G10+410) ROOF15 _ - MODULES:0 • ROOF 17 - PITCH:34* � � �:4� INDICATES NEW PV SOLAR MODULE.RED MODULES 1 SE3800H-USSNBBLI4 ORIENTATION:84° M INDICATES EXISTING METER LOCATION INDICATE PANELS THAT USE MICRO INVERTERS. DC INDICATES NEW OC DISCONNECT ROOF 16 _= REFER TO EQUIPMENT-SCHEDULE FOR SPECS. - MODULES:o OTHER OBSTRUCTIONS PITCH:ATI INDICATES EXISTING ELECTRICAL PANEL INDICATES NEW PRODUCTION METER TO BE IWS ORIENTATION:264° LOCATION: IN BASEMENT n INSTALLED OUTSIDE. SD INDICATES EXISTING SERVICE DISCONNECT A R - - MODULES:O PITCH:14° INDICATES NEW INVERTER TO BE ORIENTATION:263' D INDICATES NEW FUSED PV DISCONNECT TO BE ® INSTALLED OUTSIDE. INDICATES EXISTING TRANSFER SWITCH 2211 Allenwood Road 877-786-7283 E INSTALLED OUTSIDE(UTILITY ACCESSIBLE) A TS Wall,New Jersey 07719 www.Trinity-Solar.com REFER TO EQUIPMENT SCHEDULE FOR SPECS Y Y Engineer/License Holder: ARRAY CIRCUIT WIRING NOTES 'r 1.)LICENSED ELECTRICIAN ASSUMES ALL RESPONSIBILITY FOR DETERMINING ONSITE CONDITIONS AND EXECUTING INSTALLATION IN ACCORDANCE WITH SOLAR MODULES MOUNTED TO ROOF ON 1 ARRAY NEC 2017 12-41OW MODULES W/1 SOLAR EDGE S440 PER MODULE 15 ADC MAX PER STRING ' 2.)LOWEST EXPECTED AMBIENT TEMPERATURE BASED ON ASHRAE MINIMUM MEAN EXTREME DRY BULB 1STRINGOFI2MODULESINSERIES-380Vmax ___ ______ 8x8 -----_--- Div JUNCTION ------------------------------------------------ TEMPERATUREFORASHRAE LOCATION MOSTSIMILARTO F BOX I � INSTALLATION LOCATION. LOWEST EXPECTED AMBIENT TEMP=-16"C I 3.)HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASED 'TERMINATED INSIDE INVERTER 1 _ ON ASHRAE HIGHEST MONTH 2%DRY BULB 1 100315 TEMPERATURE FOR ASHRAE LOCATION MOST SIMILOTO I /� ` V INSTALLATION LOCATION. HIGHEST CONTINUOUS TEMP= I AA�FfSSlO�P� 33°C I I 4.)2005 ASHRAE FUNDAMENTALS 2%DESIGN I TEMPERATURES DO NOT EXCEED 47°C IN THE UNITED I EX p: 12 31/2026 STATES(PALM SPRINGS,CA IS 44.1°C). FOR LESS THAN 9 I CURRENT-CARRYING CONDUCTORS IN A ROOF-MOUNTED I SUNLIT CONDUITAT LEASTO.5"ABOVE ROOF AND USING I Issued/Revisions THE OUTDOOR DESIGN TEMPERATURE OF 47°C OR LESS (ALL OF UNITED STATES) _ I 5.)PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE A RAPID SHUTDOWN FUNCTION THAT Pi ISSUED TO TOWNSHIP FOR PEPMrt I2/21/2024 CONTROLS SPECIFIC CONDUCTORS IN ACCORDANCE WITH I NEC 690.12(A)THROUGH(D) I NO. DESCRIPTION DATE 6.)PHOTOVOLTAIC POWER SYSTEMS SHALL BE PERMITTED I TO OPERATE WITH UNGROUNDED PHOTOVOLTAIC Project Title:I SOURCE AND OUTPUTCIRCUTTAS PER NEC690.41(A)(4) I DAVID S FRANKEL- 7.)UNGROUNDED DC CIRCUIT CONDUCTORS SHALL BE IDENTIFIED WITH THE FOLLOWING OUTER FINISH: EXISTING I TRINITY ACCT#:2024-07-1126401 POSITIVE CONDUCTORS=RED MAIN BREAKER LOAD CENTER NEGATIVE CONDUCTORS=BLACK EXISTING INSULATED LINE TAPS _ NEC 210.5(C)(2) 120/240V INSTALLED ON MAIN FEEDERS Project Address: UTILITY METER NEC 705.12(A) I 8.)ARRAY AND SUB ARRAY CONDUCTORS SHALL BE#10 PV 240V 10 NOTE' I WIRE TYPE RHW-2 OR EQUIVELANTAND SHALL BE . INTERNAL REVENUE GRADE MONITORING 16465 NEW SUFFOLK AVENUE 150A MAIN BREAKER PROTECTED BY CONDUIT WHERE EXPOSED TO DIRECT I CONTAINED WITHIN NY SUNLIGHT.SUB ARRAY CONDUIT LONGER THAN 24"SHALL 150ABUSBAR i NEWS9915,- 2.4756 56 SOLAR EDGE PN.RWND-3D-240-MB 40.9915,-72.4756 CONTAIN 5 20 CURRENT CARYING CONDUCTORS AND I WHERE EXPOSEDTO DIRECTSUNLIGHT SHALL CONTAIN 5 9 CURRENT CARRYING CONDUCTORS. DrawingTitle: I 9.)ALL WIRE LENGTHS SHALL BE LESS THAN 100'UNLESS �F I OTHERWISE NOTED FLEXIBLE ROOFTOP SHALL B PROPOSED PV SOLAR SYSTEM SHALL NOT BE INSTALLED ON ROOFTOP AND SHALL BE LIMITED TO 12"IF USED LOCKABLE 60A DISCONNECT OUTDOORS FUSED W/20A FUSES D INVERTER#1 11.)OVERCURRENTPROTECTlON FOR CONDUCTORS 240V 10 Drawing Information CONNECTED TO THE SUPPLY SIDE OF A SERVICE SHALL BE e m m e m ---a+ " I DRAWING DATE: 11/21/2024 LOCATED WITHIN 10'OF THE POINT OF CONNECTION NEC T I DRAWN BY: KTD 705.31 REVISED BY: 12.)WHERE TWO SOURCES FEED A BUSSBAR,ONE ALl I �� J UTILITY AND THE OTHER AN INVERTER,PV BACKFEED I I I mLm I I - Ll L2 N 1 r BREAKER(S)SHALL BE LOCATED OPPOSITE FROM UTILITY I 0 m I L ---------------------------- -� 0 System Information: . NEC 705.12(B)(2)(3)(b) I -) -J I I DCSYSTEMSIZE: 4.92kW i -- L----- SQUARED I �`-_----J AC SYSTEM SIZE: 3.8kW 13.)ALL SOLAR SYSTEM LOAD CENTERS TO CONTAIN ONLY - ------- PN:D222NRB I I GENERATION CIRCUITS AND NO UNUSED POSITIONS OR _ ---------A MODULECOUNT: 12 LOADS MODULES USED: HANWHA410 MODULE SPECM Q.PEAK DUO BLK ML-G10+410 14.)ALL EQUIPMENT INSTALLED OUTDOORS SHALL HAVE UTILITY COMPANY: PSEG-LI A NEMA 311 RATING UTILITY ACCi#: CALCULATIONS FOR CURRENT CARRYING CONDUCTORS UTILITY METER#: REQUIRED CONDUCTOR AMPACITY PER STRING DEALTYPE: SUNNOVA [NEC 690.8(B)(1)]:(15.00.1.25)1=18.75A PV MODULE SPECIFICATIONS - AWG#10,DERATED AMPACITY HANWHA 410(Q.PEAK DUO BLK ML-G10+410) AMBIENT TEMP:33"C,TEMP DERATING FACTOR:.96 Rev.No. Sheet RACEWAY DERATING=2 CCC:1.00 Imp 10.89 NOTE:CONDUIT TYPE SHALL BE CHOSEN BY THE INSTALLATION CONTRACTOR (40•.96)1.00=38.40A Vmp 37.64 TO MEET OR EXCEED NEC AND LOCALAWD REQUIREMENTS 38.40A'_18.75A,THEREFORE WIRE SIZE IS VALID Voc 145.37 A #6 THWN-2 TO GEC p 1 PV 3 TOTAL AC REQUIRED CONDUCTOR AMPACITY ISC. 11.2 B I"CONDUIT W/2410 THWN-2,1410 THWN-2,1410 THWN-2 GROUND 16.00A'1.25=20.00A C I"CONDUIT W/2-#10 THWN-2,1410 THWN-2 GROUND AWG#10,DERATEDAMPACITY _ INVERTER#1-SE380OH-USSNBBLI4 AMBIENTTEMP:30°C,TEMP DERATING:1.0 D 1"CONDUIT W/2410 THWN-2,1410 THWN-2 GROUND RACEWAY DERATING`-3 CCC:N/A DC . AC 0 40A•1.0=40A Imp 10.5 Pout 3800 E 3/4"CONDUIT W/2-#10THWN-2,1-#30THWN-2,1-#10THWN-2GROUND 40A'_20.00A,THEREFORE AC WIRE SIZE IS VALID Vmp 380 Imax 16 F #10 PV WIRE(FREE AIR)W/#6 BARE COPPER BOND TO ARRAY lay CALCULATION FOR PV OVERCURRENT PROTECTION Voc 480 OCPDmin 20 TOTAL INVERTER I6.00A Isc 15 Vnom 240 G 1"CONDUR W/2-#6 THWN-2, -#6 THWN-2 *SOLAR CURRENT: 16.00A'1.25=20.00A 2211 Allenwood Road 877-786-7283 ->20A OVERCURRENT PROTECTION IS VALID Wall,New Jersey 07719 www.Trinity-Solar.com