Loading...
HomeMy WebLinkAbout52017-Z TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 52017 Date: 06/18/2025 Permission is hereby granted to: Birenbaum S Revoc Trt 599 11th St Brooklyn, NY 11215 To: Install roof mounted solar panels to an existing single-family dwelling as applied for per manufacturers specifications. Additional certification may be required. Premises Located at: 70 Ships Dr, Southold, NY 11971 SCTM#79.-3-11 Pursuant to application dated 05/19/2025 and approved by the Building Inspector. To expire on 06/18/2027. Contractors: Required Inspections: Fees: SOLAR PANELS $100.00 CO Single Family Dwelling-Addition /Alteration $100.00 ELECTRIC -Residential $125.00 Total S325.00 49- Building Inspector � t TOWN OF SOUTHOLD-BUILDING DEPARTMENT a Town Hall Annex 54375 Main Road P. O. Box 1179 Southold, NY 11971-0959 ` Telephone (631) 765-1802 Fax (631) 765-9502 htti)s:/iwww.sotltlioldtownn ova p� Date Received APPLICATION For Office Use Only '',, . PERMIT NO. Building Inspectar, Dy Applications and forms must be filled out in their entirety. Incomplete applications will not be accepted. Where the Applicant is not the owner,an Owner's Authorization form(Page 2)shall be completed. Date: 5/9/2025 OWNER(S)OF PROPERTY: Name: Steve Birenbaum T�SCTM # 00- 079.00-03.00-011.000 Project Address: 70 Ships Drive, Southold, NY, 11971 Phone#: (917) 456-6320 Email: steve.birenbaum@agmail.com Mailing Address: 70 Ships Drive, Southold, NY, 11971 CONTACT PERSON: Name: Katelyn Tornetta Mailing Address: 2941 Sunrise Hwy, Islip Terrace, NY 11752 Phone #: ( 631) 647-3402 [Eail- h�ppermitting@harvestpower. net DESIGN PROFESSIONAL INFORMATION: Name: Michael Dunn, R.A. Mailing Address: 256 Orinoco Dr, Brihtwaters, NY 11718 Phone #: ( 631) 665-9619 JEmail: Bayblueprint@aol . com CONTRACTOR INFORMATION: Name: Harvest Power LLC Mailing Address: 2941 Sunrise Hwy, Islip Terrace, NY 11752 Phone #: ( 631) 647-3402 Email: hppermitting@harvestpower. net DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ®Alteration ❑Repair ❑Demolition Estimated Cost of Project: ❑other $ 26 804.00 Will the lot be re-graded? ❑Yes ®No Will excess fill be removed from premises? Dyes 1gNo 1 PROPERTY INFORMATION Existing use of property: Residence Intended use of property: (no change) 'n which remises is situated: Are there an covenants and restrictions with respect to e or use district I h Zon Y p this property? ❑Yes ®No IF YES, PROVIDE A COPY. ® Cheek Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print name): Katelyn Tornetta MAuthorized Agent ❑Owner Signature of Applicant: Date: 5/9/25 STATE OF NEW YORK) SS: COUNTY OF Suffolk Katel n Tornetta being duly sworn, deposes and says that (s)he is the applicant (Name of individual signing contract) above named, (S)he is the Authorized Agent Contractor ..... 1rnntrnrtnr, Aaaant, Corporate Officer, etc. of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this �fh f 81 -a 2025 —day aMICHAELCAJ.YiSE Notary Public Notary Public-State of New York NO.91CA0035256 Qualified in Suffolk County My Commission Ewes Mar 29,2029 ROPERTY OWNER AUTHOWAT110N �...... ........... ._.. ..... .._ ..� ... ......( :re � applcaWrit�is " " . i, Steve Birtmbaum, residing at 70 Ships Drive, Sotuhold,NY 11971 do hereby authorize Katel n Tornetta- Hai-vest Power LLC to apply on my beh4ft the Town of Southold Building Department for approval as described herein. 5/9/2025 Owners Signature Date Steve Birenbaum Print Owner's Name 2 520 1-7 - M-ecs-soRs .I q-3- 1 1 Graham Consulting Corp 256 Orinoco Drive Suite A Brightwaters,NY 11718 Planning& Design (631)665-9619 May 14, 2025 Town of Southold Building Department 54375 Rt. 25 Southold, NY 11971 l Re: Steve Birenbaum Residence 70 Ships Drive Southold, NY Proposed 7.36 kWDC, 6.08 kWAC PV System To Whom It May Concern, Please be advised that I have analyzed the existing roof structure at the above-mentioned premises and have determined that it is adequate to support the additional load of the solar panels and a 140 mph wind load and 20 psf snow load without overstress, in accordance with the following: The 2020 New York State Uniform Fire Prevention and Residential Building Code; Town of Southold Local Code, Long Island Unified Solar Permit Initiative, (LIUSPI); and 2020 National Electric Code NFPA 70/2020 National Electric Code including ASCE7-16 If you have any further questions, do not hesitate to call. e� r)+ ,. Miclial'I `burin, RA - OTOVOLTAIC -ROOF - MOUNT SYSTEM H fill , 16 MODULES-ROOF MOUNTED 7.36 kWDC, 6.08 MAC Sa01 ] 70 SHIPS DR,- SOUTHOLD, NY 11971 , USA RVESTPowER HARVEST POWER LLC 2941 SUNRISE HIGHWAY ISLIP SYSTEM SUMMARY: GOVERNING CODES' SHEET INDEX TERRACE;NY 11752 TEL:(801)989-3585 (N) 16-REC SOLAR REC460AA PURE-RX(460W)MODULES 2017 NATIONAL ELECTRICAL CODE PV-0 COVER SHEET website:www.harvestpower.net (N) 16-ENPHASE IQ8X-80-M=US MICR0-INVERTERS 2020 NEW YORK STATE UNIFORM CODE PV-1 SITE PLAN WITH ROOF PLAN � � (N)JUNCTION BOX 2020 NEW'YORK STATE RESIDENTIAL CODE PV-2 ATTACHMENT DETAILS �\c ,9� (E)200A MAIN SERVICE PANEL WITH (E)200A MAIN BREAKER PV-3 THREE LINE DIAGRAM f (N)60A FUSED AC DISCONNECT PV-4 PLACARD&WARNING LA S (N) ENPHASE IQ COMBINER BOX PV-5 ADDITIONAL NOTES .� PV-6+ SPEC SHEETS va�b Z a 7 m DESIGN CRITERIA: '\0"sa ROOF TYPE:-ASPHALT SHINGLE '� T �`y VERSION �ECRIPTION DATE REV NUMBER OF LAYERS'-1 p I•E��'o �ti : ROOF CONDITION: OK BLDG.PERMIT 05/13/2025 U ROOF FRAME:-2"X6"RAFTERS @16"O.C. STORY:-ONE STORY SNOW LOAD :-25 PSF WIND SPEED :-130 MPH WIND EXPOSURE:-D IV GENERAL NOTES: ARRAY LOCATIONS ' _ 1. INSTALLATION IN ACCORDANCE WITH MANUFACTURER �wapingfora " �' ' PROJECT SITE RECOMMENDATIONS. . . . . . ; s y F 2. ENGINEER TO INSPECT PROJECT AFTER INSTALLATION AND CERTIFY COMPLIANCE. '= ` i , 3. PROJECT TO BE INSTALLED WITH CODE COMPLIANT ` RACKING INSTRUCTIONS FOR UNI-RAC SOLAR MOUNTS PROJECT NAME SYSTEM. .,, lew-Haven ` 4. FOLLOW BALLASTING SCHEDULE ON ROOF PLAN. I ' 5. HARVEST POWER, LLC.,THE SOLAR INSTALLATION O CONTRACTOR,COMPLIES WITH ALL LICENSING&ALL C) O RELATED REQUIREMENTS OF THE GOVERNING T' t#fpct Island '2 MUNICIPALITIES AND THE LOCAL ELECTRIC UTILITY f ,'_' Q _ O AHJ'S. i d m O O Q 6. THIS PROJECT WILL COMPLY WITH THE CURRENT NEC '' _ REQUIREMENTS INCLUDING ARTICLE. SOLAR ton !stand Salrnd = W p Z REQ 5 O PHOTOVOLTAIC PV SYSTEMS. `s Z O L- 7. THE ROOF.WILL HAVE NO MORE THAN A SINGLE LAYER :/ CO = O F- O OF ROOF.COVERING`IN ADDITION TO THE SOLAR t 70 Shlps Dr, , ,-I East . ..: „. W 0 O EQUIPMENT. r >' 8. INSTALLATION WILL BE FLUSH-MOUNTED, PARALLEL SOutfiOld,NY`11977, Hampton Lu ti O o TO AND NO MORE THAN 6.5"ABOVE ROOF �` .�_. Wetling i ;Un'ted States ;a_-'' I— T F— .` 9. MAINTAIN A MINIMUM OF 18"CLEARANCE AT RIDGE Rry u) RiVAND AT ONE GABLE EAVE. ` � d __ Z 10. THIS DESIGN COMPLIES WITH 130 MPH WIND e O Q Q REQUIREMENTS OF THE RESIDENTIAL CODE OF N.Y.S �mK i F Manor+n!e AND ASCE.7-16. `QUOgU2' 11. WHEREVER THE ROOF PLAN DOES NOT COMPLY WITH °~Shirley , SHEET NAME ACCESS AND VENTILATION REQUIREMENTS OF.THE ; UNIFORM CODE, HARVEST POWER PROPOSES THAT COVER SHEET ALTERNATIVE VENTILATION METHODS WILL BE EMPLOYED. REVIEW AND APPROVAL SHALL BE AT-THE SHEET SIZE DISCRETION OF THE MUNICIPALITY IN WHICH THIS DOCUMENT HAS BEEN FILED. ANSI B 12. THE DESIGN PLANS COMPLY WITH THE 2020 NEW 11" X 17" YORK STATE UNIFORM FIRE PREVENTION AND RESIDENTIAL BUILDING CODE. 1 AERIAL PHOTO VICINITY MAP SHEET NUMBER PV-0 SCALE: NTS PV-0 SCALE: NTS �r PV-Q q ROOF MODULE TYPE, DIMENSIONS & WEIGHT SHALL ACCESS B BE LOCATED S ARECATED I ' SHAE LO IN AREAS THAT DO NOT REQUIRE THE NUMBER OF MODULES= 16 MODULES PLACEMENT OF GROUND-OVER OPENINGS SUCH AS WINDOWS OR MODULE TYPE= REC SOLAR REC460AA PURE-RX(460W)MODULES DOORS,AND LOCATED AT STRONG POINTS OF BUILDING p MODULE WEIGHT=51.5 LBS/23.4 KG. CONSTRUCTION IN LOCATIONS WHERE THE ACCESS POINT DOES MODULE DIMENSIONS= 68.03"X 47.44"=22.41 SF NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE UNIT WEIGHT OF ARRAY=2.30 PSF LIMBS,WIRES OR SIGNS. HARVESTPOWER HARVEST POWER LLC (16) ENPHASE IQ$X-80-M-US 2941 SUNRISE HIGHWAY ISLIP (E) DETACHED STRUCTURE MICRO-INVERTERS TER SO)9 9 RACE,NY 175 wehsite:www.harvestpowernet 585 ROOF#2 , SIy�I .(06) REC460AA PURE-RX(460W) RAFTERS=2"X6"@16"O.0 �r�� A 193'AZIMUTH, 18'TILT z '� -_ (E) PATHWAY l �(4-1 500 (N)JUNCTION BOX gfi � < " y p �a r 1 RIJp �cEss 6,.`\ 7 V SION � �TIo DATE REV. J�� ROOF#3 BtD MIT 05/13/2025 0 c( (03) REC460AA PURE-RX(460W) W ONE 93'AZIMUTH 81 T C TILT CO O to SEE ENLARGE VIEW PROJECT NAME �t CO . • O 2 ❑ O CD O CD Lu Z ( 1� (Cr(� CCES co �/ ` > (�` J) AREA C . IJ_ 0 Q J WCD �.-, ; zJ (n �, pa �(C� �'J� r� ��< (N) 1 PVC CONDUIT ""' c ce a_.z H �'�J-��( r ��(�v J) I RUN 7/8 ABOVE ROOF gRFEAss m _ J O ( ) Rc W U) ❑ O Z a (< i � RooF cgs; 1 I` JO o(E)200A.MAIN SERVICE PANEL AREq O PROPERCvJ)�) (� ( WITH (E)200A MAIN BREAKER _ W O O r�INE (� J) C�c..J) �) (INSIDE) I-- F- 137�8, �r �, 'J (E) UTILITY METER U) ❑ Z (E)GATE(TYP.) (N)60A FUSED AC DISCONNECT O Q Q (N) ENPHASE IQ COMBINER BOX (E).TREE(TYP.) ROOF#1 SHEET NAME (07) REC460AA PURE-RX(460W) SITE PLAN WITH RAFTERS=2"X6"@16" O.0 ROOF PLAN 193'AZIMUTH, 18'TILT SHEET SIZE ANSI B J 1 11" X 17" SITE PLAN WITH ROOF PLAN ENLARGE VIEW SHEET NUMBER 1 SCALE: 1/32"= 1'-0" 2 SCALE: NTS PV-.1 p A PV MODULES HARVESTPOWER HARVEST POWER LLC 2941 SUNRISE HIGHWAY ISLIP TERRACE,.NY 11752 TEL:(801)989-3585 SEE ENLARGED VIEW �6� 0 G website:www.harvestpowernet c HA (E) ASPHALT SHINGLE ROOF t`' ? o js\\ GENERAL NOTES: I!,^ VERSION 1. RAILS TO BE INSTALLED TWO PER PANELS AS SHO TAHL E`' ESCRIPTION DATE REV. 2. ALL PENETRATIONS TO BE MADE@ 48"O.C. BLDG.PERMIT 05/13/2025 0 3. BOLTS TOBE INSTALLED INTO RAFTERS. 4. MINIMUM 2.5"PENETRATION INTO WOOD FOR CODE COMPLIANCE. NOTE.- ATTACHMENT DETAIL "ACTUAL ROOF CONDITIONS AND RAFTERS-(OR SEAM) LOCATIONS MAY VARY. INSTALL PER.MANUFACTURER(S)INSTALLATION GUIDELINES SCALE:NTS AND ENGINEERED SPANS FOR ATTACHMENTS." END] MID CLAMP PV MODULES PROJECT NAME cat Q O 0 O J 0 m 0-) Q L-FOOT W o Z O (E) ASPHALT SHINGLE ROOF m. = Z J O O W cn ❑ o Z (N) UNIRAC W ti O= o = O SM STANDARD RAIL ROOF/ DECK MEMBRANE w CD: *k a (E) 2"X6" RAFTERS @ 16" O.0 2.5" MIN.' EMBEDMENT SHEET NAME ATTACHMENT FLASH KIT PRO FLASHING DETAIL SHEET SIZE ANSI B: . BUILDING STRUCTURE 5/16" STAINLESS STEEL LAG BOLT 11" X 17" WITH SS EPDM BONDED WASHER, 2-1/2" MIN. EMBEDMENT. ATTACHMENT DETAIL -ENLARGE VIEW) SHEETNUMBER 2 SCALE: NTS PV-2 (16) REC SOLAR REC460AA PURE-RX(460W) MODULES BILL OF MATERIALS (16),ENPHAiSE IQ8X-80-M-US MICRO-INVERTERS EQUIPMENT QTY DESCRIPTION (02) BRANCHES OF 08 MODULES CONNECTED IN PARALLEL PER BRANCH SOLAR PV MODULE 16 REC SOLAR REC460AA PURE-RX(46OW)MODULES p MICRO-INVERTER 16 ENPHASE IQ8X-80-M-US MICRO-INVERTERS SYSTEM SIZE:- 16 X 460W=7.36 kWDC COMBINER BOX 1 ENPHASE IQ COMBINER BOX 16 x 380VA=6.08 kWi4C JUNCTION BOX 1 600V,55A MAX,4 INPUTS,MOUNTED ON ROOF FOR WIRE&CONDUIT TRANSITION HARVESTPOWER HARVEST POWER LLC AC DISCONNECT 1. AC DISCONNECT 60A FUSED,WITH 40A/2P FUSES,240V NEMA 3R,UL LISTED 2941 SUNRISE HIGHWAY ISLIP TERRACE,NY 11752 TEL:_(801)9B9-3585. _ �ftbsi . ww.harvest owernet co 79D a h„l Z F . VERSION DESCRIPTION DATE REV. TO UTILITY GRID BLDG.PERMIT 05/13/2025 0 08 MICRO-INVERTERS IN BRANCH CIRCUIT#1 . . . L1L2N BI-DIRECTIONAL UTILITY METER (N)ENPHASE M 1-PHASE,3-W, 1 COMBINER BOX 120V/240V AV ` ---_---- '`—i--------=---- `—�------� .' ' LINE SIDE TAP 1 08 MICRO=INVERTERS IN BRANCH CIRCUIT#2 I � 15A" - (N)AC DISCONNECT 60A N I N JUNCTION BOX FUSED,VISIBLE LOCKABLE 200A - -- • • • _. .. I ( ) PROJECT NAME - --- R.- I LABELED,40A FUSES, 1 . 20A 24o vAC ILEE _ L L (E)200A MAIN Q c ti I ti i ti I 1 20A 40A FUSES 0 0— SERVICE PANEL O ❑ /--=----- �-------=---- ��,----=� L1 L1 .. O. AIN BREAKER = O CC G - L2 L2 r------i (TOP FED) O 1 L' L I I m LJ� C7 O IQ (L16).ENPHASE IQ8X-80-M-US 1 M' N N GATEWA I I z ❑ Cr) MICRO-INVERTERS j i-----=--- -- ------ G -----. __ ----� i N..CG] WN 00 Z U� L--- 1 — -- �T LL G _ c _ z 0 N — TERMINATOR CAP ON LAST CABLE O CONNECTOR Q-CABLE(TYP) GROUNDING LI..I O (2)Q-CABLE (4)10 AWG THWN-2 (3)#6 BLK RED THHN (2)#6 BLK RED THHN ELECTRODE SYSTEM L> ~ O( (1)PV 6 BARE CU GND (1)#6 THHN STRANDED G#6 WHT THHN STRANDED (1)#6 WHT THHN _ O GREEN GROUND IN 1"PVC (1)#6 THHN STRANDED I— GREEN GROUND CONDUIT RUN GREEN GROUND IN 1"PVC U) ❑ IN 1"PVC CONDUIT CONDUIT RUN � Q SHEET NAME THREE LINE DIAGRAM SHEET SIZE ANSI B:.. 11" X 17�� THREE LINE DIAGRAM SHEET NUMBER SCALE: NITS PV-3 ELECTRICAL SHOCK HAZARD PHOTOVOLTAIC SYSTEM• S U Aid P'1�l S S E M E Q U P P - COMBINER PANEL TERMINALS ON LINE AND LOAD DO NOT ADD LOADS IJ 1/Y ftl HARVESTPOWER SIDES MAY BE ENERGIZED IN HARVEST POWER LLC THE OPEN POSITION LABEL LOCATION: 2941 SUNRISE HIGHWAY ISLIP _ PHOTOVOLTAIC AC COMBINER(IF TERRACE,NY 11752 " . a 585 APPLICABLE). website:www.baves owe rnet LABEL LOCATION: E ),AC DISCONNECT(S),AC TURN RAPID SHUTDOWN COMBINER PANEL(IF APPLICABLE). � \� ��� . SWITCH TO THE"OFF" SO ly @LE�LC7W C� POSITION TO SHUT DOWN '�a PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY.RAPID SHUTDOWN SWITCO to 2 7 � di/ I ,� ..^.``:° ^-r VERSION FOR • ' �. PV DESCRIPTION DATE REV. LABEL LOCATION: BLDG.PERMIT 65/13/2025 0 ON OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE LABEL LOCATION: ' DISCONNECTING MEANS TO WHICH THE PV SYSTEMS UTILITY SERVICE:ENTRANCE/METER,INVERTER/DC ARE CONNECTED. DISCONNECT IF REQUIRED BY LOCAL AHJ,OR OTHER LOCATIONS AS REQUIRED BY LOCAL AHJ. POWER SOURCE OUTPUT CONNECTION DO NOT RELOCATE THIS PROJECT NAME OVERCURRENT DEVICE LABEL LOCATION: ADJACENT TO PV BREAKER-AND ESS O J OCPD(IF APPLICABLE). BUILDING SUPPLIED BY UTILITY Q o 0 GRID AND PHOTOVOLTAIC z o M Q o SYSTEM ww U) - o z U) a o U- WARNING:• �PHOTOVOLTAIC. 70 SHIPS DR m 2 Z ~ 0 ■ • ■ • . (N)PV MODULES U) Q. O w z> J O ~ LABEL LOCATION: W O O O O INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, ~ AT EACH TURN,ABOVE AND BELOW PENETRATIONS, ON-EVERY JB/PULL BOX.CONTAINING DC CIRCUITS. - O z Q Q . PHOTOVOLTAIC • . DISCONNECT SHEET NAME MAXIMUM AC O. ;AMPS ' PLACARD & (E)MAIN SERVICE PANEL WARNING.-LABELS NOMINAL OPERATING AC VOLTAGE: . . (INSIDE) (E)UTILITY METER SHEET SIZE LABEL LOCATION: (N)AC DISCONNECT AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF (N)COMBINER BOX ANSI B INTERCONNECTION. 1 1!' X 17" LABEL LOCATION: SHEET NUMBER POINT OF INTERCONNECTION \, (PER CODE:NEC690.56(B),NEC705.10,225.37,230.2(E)) P V—mot . a 1. EACH MODULE TO BE GROUNDED USING THE SUPPLIED CONNECTION POINT PER MANUFACTURER'S REQUIREMENTS. ALL SOLAR MODULES, EQUIPMENT, AND METALLIC COMPONENTS ARE TO BE BONDED, IF THE EXISTING GROUNDING HARVESTPOWER ELECTRODE SYSTEM CAN NOT BE VERIFIED OR IS-ONLY METALLIC WATER PIPING, HARVEST POWER LLC 2941 SUNRISE HIGHWAY ISLIP , IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSTALL A SUPPLEMENTAL TERRACE,NY11752 GROUNDING ELECTRODE. TEL:.(eo1)9893585 �� a '�,�^ website:www.harvest owernet 2. ALL PLAQUES AND SIGNAGE REQUIRED:BY THE LATEST EDITION OF NATIONAL ' y ELECTRICAL CODE. LABEL SHALL BE METALLIC OR PLASTIC, ENGRAVED OR z m MACHINE PRINTED IN A CONTRASTING COLOR TO THE PLAQUE. PLAQUE SHALL BE UV RESISTANT IF EXP-OSED TO SUNLIGHT. o�w�� y 17 3. AC CONDUCTORS SHALL BE RUN IN EMT.AND SHALL BE LABELED, "CAUTION AC off,y 0, VERSION VERSION DESCRIPTION DATE REV. CIRCUIT" OR EQUIV. EVERY 5 FT. BLDG.PERMIT 'Q5/13/2025 0 4. EXPOSED NON-CURRENT CARRYING METAL PARTS OF ELECTRICAL EQUIPMENT SHALL BE GROUNDED IN ACCORDANCE WITH 250.134 OR 250.136(A). 5. CONFIRM LINE SIDE VOLTAGE AT ELECTRIC UTILITY SERVICE PRIOR TO CONNECTING INVERTER. VERIFY SERVICE VOLTAGE IS WITHIN INVERTER VOLTAGE OPERATIONAL RANGE. 6. OUTDOOR EQUIPMENT SHALL BE NEMA-3R RATED OR BETTER. PROJECT NAME 7. ELECTRICAL CONTRACTOR TO PROVIDE CONDUIT EXPANSION JOINTS AND ANCHOR: CONDUIT'RUNS AS REQUIRED;PER NEC. U) o 0 8. ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL Q ti � MEANS DESIGNED AND LISTED FOR SUCH USE, Z o AND FOR ROOF-MOUNTED m 0 °� o Q 0 ' � oz 0 SYSTEMS; WIRING MUST BE PERMANENTLY AND COMPLETELY HELP OFF OF THE. W U) o ROOF:SURFACE. NEC 110.2 - 110.4 /.300.4 =` Z m = Z 0 0 9. .ALL ROOF PENETRATIONS MUST BE-FLASHED. SIMPLY CAULKING DOES NOT w C) SUFFICE. W ~ 0= 0 0 I-- U) O z � Q ' Q SHEET NAME ADDITIONAL.NOTES SHEET.SIZE ANSI B 11" X 17" SHEET NUMBER PV-5 __ LAR'S MOST LISTED. E .. O . : . � HARVESTP®VNER � HARVEST POWER LLC 2941 SUNRISE HIGHWAY ISLIP TERRACE NY11752 TEL:(801)989-3585 • CaENEKAL 6JATA >zaus sss _ t = 88 half cut REC bifaual heter'unction cells Cell v ehsite:www.harvest ower.net I with lead-free,Saplesstechnology JHA s y �9 Glass: 3.2mmsolarglasswithantF-reFlectivesurfacetreatment a t. ... in N121 er m ,'IT cordancewithE 50 s B cksh6e: Highly resistantpolym _ Frame: Anodized aluminum(black) „ + sq / -Junction 4-part r * - IP6E rated in accordance with IEC 62790 Connectors: Staubli MC4 PV-KBT4/KST4(4 mm2 �y REC.. 1onnec ors: ut accordance lEC 62852,IP68onlywhen connected � y Cable: 4mm=sdlarcable,1.7+1.7rh t I ' 5ER v in accordance with EN50618 ; S. L 9 y �� VERSION PURE RX Dimensions: 1728x1ZO5x30mm(2.OSm�) ' .. S�� y`_,`'ti"°- ,+s. Weight. :..' 23.4 kg zss 'o DATE 2025 REV. • � � DESCRIPTION Origin: MadeinSingapore BLDG.PERMIT 0 PRODUCT :SPECIFICATIONS $ `^ Measurements in mm u E E T i : DAT' Pra uctCode`,I2ECxxxAAPure RX CE i fFCATIQNS IEC61215:2021,IEC61730:2016,1JL61730. PowerOdtput-P�(Wp) �' 450 460 .'470 • Watt Class Sorting-(W) 0/«10 0/+10 0/+10 IEC62804 PID IEC 61701 Salt Mist NommalPowerVol[age-VM (V), 54;3. 54-9 55.4. IEC62716 Ammonia Resistance u Nominal Power Current-I (A) 8.29 8.38 8.49 ISb119252 Ignitability(EN 135011 Class E). IEC62782 namic Mechanical Load 'n Open C'lrcuitVoltage-V"(V) 65.1 653. -65.6 IEC6121522016 Hilstone(35mm) Short Circuit Current-Isc(A) 8.81 8.88 8.95 IEC623Z1 Lead-freeacc.toRoHSEUB63/2015 PowerDensity(W/mz) 216.' 221 226: IEG61730-2:2016 Fire Class C(as per UL790) Panel Efficiency(%) 21.6 22.1 226 15014001,ISO 9001,IEC 45001.IEC 62941 PowerOut ut-P W 343 350" 358 ` K9 0/7 P tux( P).. L.,aF. PROJECT NAME Nominal Power Voltage-V�v(V) 512 51.7 522 u.cmvo Nominal Power Current-I+�(A). 6.70.. 6.77 6.86, Dedare. O z Open CircuitVoltage-Voc(V) 61.3 61.6 61.8 o Q ShoribrcuitCurrent-QjA) 7.11 7.17 . 7.23 EMPERATURERATINS(i O O ` : Valuesatstandard test cundiC�ns(STC air mass AM 1.5,irradiance1000 W/m',temperature 75"C),based onaproduction spreadvritha Nominal Module OperatingTemperature: 44'C(+•2•C) � toleranceofP,,,,F.V,x&tx=3%withcFonewattclass.Norrimimoduleopemtingtemperatum(NMOT:abrma AM15,"urarYi x 800W/m2, Temperature coefficient of P.: -0.24%/'C Q ^ O 'l COMPACT mgi tmture 20°C.wuxlspeedl m/sj*Where xxx indicates thenommalpower dass(P.)atSTC abo.- 1 Temperature coefficient ofVcc: -0.24%/°C 6 my Q D t 7{kt i .RAT)NG- ARRAIdTY O Q Temperature coefficient oflsc: 0.04%/°C Z M z U) Operationaltempe.raturei' .40...+85•C Standard'."RECPmTntst '. The temperature coefficients stated arelinearvalues W O Maximumsystemvoltage: 1000V InstalledbyanREC No Yes Yes - 0- Z O LL • ■1 " Certified Solar Professional SLIVERY INFOR94 TIDN _ _ z O 'Maximum test load(front): . +7000Pa(713kg/m2)' System Size All c25kW 25 SOOkW O Panels per pallet COMPATIBLE + - i : 33 m m = ^ Maximumtest load(rear): -4000Pa(407kg/m2)' Product Warranty(yrs) 20 25 25 o J Panels per40ftGP/high cube container: 594(18pallets) _ w � 0 O - Z Max series fuse rating 25A Power Warranty(yrs) 25. . 25 25 J Panelsper13.6mtruck 660(20pallets) ^ \ O ~ Max reverse current: 25A Labor Warranty(yrs) 0 25 10 a 1'/' O Q O 'See installation manual formountin instructions. Power in,Year '�98% 98% ���98% W g p 1177.4 t3EAA 70 R o = L r Design load-Testload/15(safety factor) Annual Degradation 0.25% 025% 0.25% r - Typical low irradiance performance ofinoduleatSTC: + - Power inYear25 • 92% : 92% 92% The REC ProTmst Warrantyis only--fable onpanelspurchased a through an RECCertified 5olarProfessionali�ntallecWarranty --' -"' - �'-.. conditibnsapply.See wwwrecgreup.com forma details. „�. :. ... O • w ------"--_ Q Available from: �Irradlance(Wle) SHEET NAME SPEC SHEET SHEET SIZE g RECSoIarPTE.LTD. ANSI B Founded in1996.REC Group isaninternationalpioneeringsolar energy company dedicated to empowering consumers ® �� n.. � with clean,affordable solar power.As Solar's Most Trusted,REC is committed to high quality,innovation,and a low R 20TuasSouthAve.14 s carbon footprint in the solar materials and solar panels it manufactures.Headquartered in Norway with operational Singapore 637312 <� 11 X 17n headquarters in Singapore.REC also has regional hubs in North America,Europe.and Asia-Pacific. post@recgroup.com wwwrecgroup.com SHEET NUMBER PV-6 tP-01ZLEn l ■ii POWER ILLC iSOLARMOUNT .. IJI� IRAC TERRACE,NY 11752 1 r • � 1 1 1 I I 1' � 1 � .11 1 I' 1 � \ BETTER DESIGNS TRUST THE INDUSTRYES BEST DESIGN TOOL CONCEALED UNIVERSAL o 1 I , 1 ' I , I , •, , Start the Design process for every project in our U-Builder on-line design tool. ENOCLAMPS It's a great way to save time and money. i BETTER SYSTEMS ONE SYSTEM-MANY APPLICATIONS CEM01111� - Quickly set.modules flush to the roof on steep pitched roofs.Orient a large variety �CLDGYERMIT 0 at modules in Portrait or Landscape.Till Ilia system up on flat or low slow roofs, END CAPS INCLUDED Components available in mill,clear.and dark finishes to optimize your design financials ` WITH EVERY ENOCLAMP and aesthetics. BETTER RESULTS MAXIMIZE PROFITABILITY ON EVERY JOB CONCEALED Trust'Unirac to help you minimize both system and labor costs train the time the jab is UNIVERSAL S quoted to Ilia time your teams got off the roof.Faster installs.Less Waste.More Profits. UNIVERSAL SELF CLAMPS 4 iPUNIRA(' BETTER SUPPORT STANDING MIDCLAMPS 25WORK WITH'THE INDUSTRIES MOST EXPERIENCED TEAM Professional support for professional installers and designers.You have access to PROJECT R our technical support and training'groups.Whatever your support needs.wdvc got _ t 'I OPTIONAL YEAR 1 you aoverei.Visit Unirac:com/solarmount for more information. �� C • FRONTTRIM fU[LSYSTEM � � \ J ,° • WARRANTY �� U-BUILDER ONLINE DESIGN • • , Milk- t a � TOOL SAVES TIME&MONEY BONDING&GROUNDING --» Visit design.unirac.com .AW MECHANICALLOADING -ter— �1 -._..�- • •N10-3 UL2703 SYSTEM ARE CLASSIFICATION --"` — ,• , • • • • NIRAC CUSTOMER SERVICE MEANS THE HIGHEST LEVEL OF PRODUCT SUPPORT • U • I ' I I I i I I ' ' I UNMATCHED CERTIFIED ENGINEERING BANKABLE DESIGN PERMIT •,, , „• I „ ,, I I EXPERIENCE QUALITY EXCELLENCE WARRANTY TOOLS DOCUMENTATION • ■ 1 I I I 1' 1 TECHNICAL SUPPORT CERTIFIED QUALITY PROVIDER BANKABLE WARRANTY Unirac''s technical support team is dedicated to answering Unirac is the only PV mountingvendorwith ISO Don't leaveyour projdcl to chance,Unirac has the SHEET NAME questions&addressing issues inreaftime.Anairline certifications for 9001:2008,14001:2004 and ONSAS financial strength to back our products and reduce your risk. library af documents including engineering reports. 18001:2001,whichmeanswe deliver i lie higheststandards [lave peace ulinindknowingyou are providing produclsol SPEC SHEET THE PROF ESSIONALS' CHOICE FOR RESIDENTIAL RACKING stamped letters and technical datasheetsgreatly forfit,form,and function.These certifications demonstrate exceptional quality,SOLARMOUNTis covered bya25year simplifiesyoorpermiltiugand project planningproress, our excellence and comrdilmenttatirstctassbusinosspractices. bruiled product warrardy and a5 year ljinited'finishwarranty. SHEET SIZE IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII•IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIrlllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllllll BEST INSTALLATION EXPERIENDE9 CURB APPEAL e COMPLETE SOLUTION*UNIRAC SUPPORT = ENHANCE YOUR REPUTATION WITH QUALITY RACKING SOLUTIONS BACKED BY ENGINEERING EXCELLENCE AND A SUPERIOR SUPPLY CHAIN ANSI FOR QUESTIONS OR CUSTOMER SERVICE VISIT UNIRAC.COM OR CALL, (505) 248-2702 PNB.;nnA,nit.Pdrrrrnuuefrnn FOR QUESTIONS OR CUSTOMER SERVICE VISIT UNIRAC.COM OR CALL (505) 248-2702 Fp. • Tectonic State 255724 HARVESTPOVNER Tectonic Tectonic August 12,2024 HARVEST POWER LLC 2941 SUNRISE HIGHWAY ISLIP voArncsuou�noi.:.E=cE•rwxns sepqa ea.rncu swuno,u.nnrrw,uss«nu. TERRACE,NY 11752 TEL:(801)989-3585 August 12,2024 Metal Roof: Standing Seam Attachments, PM-9000s,and. PM Adjust Slotted. - bsit..'—.ha..st owernet Tile Roof- Solar hooks, Flashkit Tile Replacement(TR) y Unirac 0 Attn: Engineering Services Department The U-Builder Tool should be used under the responsible charge of a registered 1411 Broadway Boulevard NE professional engineer required by the authority having:jurisdiction'. The design tool . fi I G =} Albuquerque,.NM 87102-1545 and Unirac do'not evaluate the existing roof structure,-or the PV panels themselves. CD {11 TEL:'(505)242-6411. See the construction and installation drawings and manuals for additional information provided by Unirac. RE: ENGINEERING. CERTIFICATION LETTER FOR THE UNIRAC SOLARMOUNT (SM) s .L VERSION ROOF PV PANEL SUPPORT SYSTEM Sincerely, OF NE(N y � �� STATE:NEW YORK p ''. bEsb�1PTION DATE REV. Tectonic ,i,P 0 A:• .Cily BLDG.PERmIT 05/13/2025 0. TECTONIC WORK ORDER :12557.25 o 9 The Unirac SOLARMOUNT(SM) Photovoltaic Panel Support System is a proprietary ¢ I - w framed photovoltaic panel support system that is installed- on a roof. Tectonic N Engineering Consultants, Geologists- & Land Surveyors, D.P.C. (Tectonic) has �0 0�1249 reviewed the SM design methodology along with the U-Builder tool;a Unirac online A �. design tool.The review included the following SM products, SM tight, Heavy Duty, S1 . 08/12/2024 and Standard rail with both the standard and pro hardware. Antonio A. Gualtieri; P.E. Tectonic. has determined that the design is a rational approach and follows the Executive Vice President structural requirements of the following reference documents: Codes/Standards: PROJECT NAME • 2020 Building Code of New York State. • 2018 International Building Code by International Code Council. • ASCE/SEI 7-16 Minimum Design Loads for Buildings and Other Structures, by o ❑ American Society of Civil Engineers with provisions from SEAOC PV-2-2017. ❑ o J • 2020 Aluminum Design Manual, by Aluminum Association. Q r- 0 This letter certifies that the structural analysis of the racking members,connections; m 0 � o Q ❑ and components directly related to Unirac's system are in compliance with the Z ❑ coo Z O above codes. The design methodology is acceptable. under components and W (q cladding loads associated With the building's roof structure when the system is a Z o LL- installed"in accordance with manufacturer specifications:If the loading criteria does m = rn O not `meet Unirac's specifications, owner shall contact Unirac for a. site-specific W o 0' o Z certification: W F_ 0 C) O Attachments approved.:for the SM system to the structure.include the.following acid is installed per Unirac's U-Builder report and installation-guides: Z = ■ Shingle Roof: L-Foot Flashkit Pro, Standoffs, Flashloc Comp; Flash Lod Duo, Q Q and Flash Kit Pro SB SHEET NAME Project Contact Info 'Project Contact Info SPEC SHEET 1279 Route 300 I Newburgh,Mf 12550 1279 Route300 I Newburgh;W 12550 845.567.6656 Tel 1845.567.8703 Fax 845.567.6656 Tel 1 845.567.8703 Fax SHEET SIZE tectmicengineering.com tectonicengineedng.com page 2 Of 2 . ANSI B Equal Opportmity Employer Equal Opportunity Employer 11" X 17' SHEET NUMBER PV-8