Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
52012-Z
TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE ' SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 52012 Date: 06/18/2025 Permission is hereby granted to: Nofoaz LLC 40817 C R 48 Southold, NY 11971 To: Install a generator accessory to an existing single-family dwelling as applied for per manufacturers specifications. Premises Located at: 40817 CR 48, Southold, NY 11971 SCTM# 59.-7-29.5 Pursuant to application dated 06/03/2025 and approved by the Building Inspector. To expire on 06/18/2027. Contractors: Required Inspections: Fees: GENERATOR $125.00 CO Accessory $100.00 ELECTRIC -Residential $100.00 Total $325.00 Building Inspector TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold, NY 11971-0959 Telephone (631) 765-1802 Fax (631) 765-9502 ltti ://w,�vw,serutlloltlLOW1l11v,gov. Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only PERMIT N0, 5 �O Building Inspector: JUN _ 2025 Applications and forms must be filled out in their entirety.Incomplete Building Department applications will not be accepted. Where the Applicant is not the owner,an Town Of Southold Owner's Authorization form(Page 2)shall be completed. Date: OWNER(S)OF PROPERTY: Name: SCTM# 1 loo- -: -7 " d �� s ,r?v - Z�✓�ode ,r Project Address: Z140 ✓^ �� O r" / �g Phone#: Email: 11 Mailing Address:`/0 7/ CONTACT PERSON: Name: Mailing Address: n iYli"w11716 !? S J� 2 . Phone#: 6, 3 Email; DESIGN PROFESSIONAL INFORMATION: Name: Mailing Address: Phone#: Email: CONTRACTOR INFORMATION: Name: r p, r11rCC' �. 7 c Mailing Address: 08 & Ckl') f �'o— 1 71 Phone#: Email: DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: Other Ge $ / 0690 .00 Will the lot be re-graded? ❑Yes FAO Will excess fill be removed from premises? ❑Yes No PROPERTY INFORMATION Existing use of property: Intended use of property: Zone or use district in which premises is situated:: Are there any covenants and restrictions with respect to this property? ❑Yes ❑No IF YES, PROVIDE A COPY. ❑Check Box After Reading: The owner/contractor/deslgn professional is responsible for all drainage and storm water Issues as provided by Chapter 236 of the Town Code. APPUCATiON IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable taws,Ordinances or Regulations,for the construction of buildings, es o com with all applicable laws ordinances,building code, add'+Sorts alterations or for removal or demolition as herein described.The applicant afire t ply pp P housing code and regulations and to admit authorized inspectors on premises and in buildingis)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section Z20AS of the New York State Penal law. Application Submitted B (print dame : j e�r� � Authorized Agent ❑Owner PP Y(P I �3 .�.�'J Signature of Applicant: ^ �F � Date: ��d o/;F 5 STATE OF NEW YORK) JANET DAMIANO �i U- NOTARY PUBLIC-STATE OF NEW YORK COUNTY OF _ _ .._._. ) No. O1 DA5061073 (o�0� II\\ Qualified in Suffolk County 10 Vic. k 1/ �� ��� ...._,._mm being duly swolPry, c�rirs depsla�nd ►/��hat(s)he is the applicant (Name of individual signing contract)above named, (S)he is the.___.__ (Contractor,Agent, Corporate Officer,etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this �6 day of , 20 12 >`— Notary Public (Where the applicant is not the owner) I .��A C-- residing at __ _. .�. do hereby authorize LI-3A- e � " e1u'«to apply on my be I t he Town of Southold Building Department for approval as clescri Ind herein. O he Signature LC Print Owner's Name 2 BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD Town Hall Annex- 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 - ro g err southoldtownny. ov - seand southoldtownn . ov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: r- 5- Company Name: t IV4 Name: ,r . -License No.: email �: Address: 47,2 & e ,1 e4 .Sa u,f " 076.1 Phone No.: . - q 41 V- 7 JOB SITE INFORMATION (All Information Required) Name: d . ' Address: / , . J � // Cross Street: , Phone No.: J _ 3,� Bldg.Permit#: email:din L4X 44 4 C�/ 6- %`!/a, Tax Map District: 1000 Section: Block: 7 Lot: i23� BRIEF DESCRIPTION OF WORK (Please Print Clearly) ,, 24 kW Circle All That Apply: Is job ready for inspection?: YES Rough In Final Do you need a Temp Certificate?: YES NO Issued On Temp Information: (All information required) Service Size 1 Ph 3 Ph Size: A # Meters Old Meter# New Service - Fire Reconnect- Flood Reconnect- Service Reconnected - Underground -Overhead '#Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION Request for Inspection FormAs FA6FY➢,R Hm C91VMm l xS AA:DT ISO IGTD—H9 UE aRRMl1EF➢— OF AVE RIO�ECRIC P.—. 1HWTOVE =N`=N�WIOE 1NE Aopnnx TO BUAOwoS�ANNONIU wN�,��A116f P XO N6 S�IIXI i� l[m�/M NSF]�IIS OF RIWM,� TNIN� � WELL/SANITARY ,x�ssAN TO THIS IS LNmwEm� 500'4 No crvaDis7oEmoA mu[wuo wDvr� nln NX aR LWfiossm wL swu WELL/SANITARY IarA,xD, asrAHDs,D Rou AND cmPooD.o o¢r rR�al� 500' IMPROVED/WELL s��osi1:AE rni e%le�ves�.icuiloi AND WELL LOT Duwzroxs 1 IMPROVED/ (TAX LOT 294) LOT 2 (TA%LOT 29 fi) 322.40' N 53'24 40'E ti sf m A 4, e Z LLLL.O E15EMENT- ��'`'} O OP } PROP.SEPTIC BEDROOMS) £ O 1-1,500 GALLON SEPTIC TANK . 2-B'OIA.0 B DEEP LEACHING POOL ROOM FOR 507.EXPANSION 8 N - $ +� 5 W - PROP.SEPTIC.(POOLHOUSE) gm W "- -401 1-1,DO GALLON SEPTIC TANK 1-B'OIA.%4'DEEP LEACHING POOL m ININSuiABLE CLEAN MUST BE REMOVED AND COLLAR DDT E Ui X THIME_CH TOOT REAM SAND AND 4AAT41 ST SIX AROUND THE 'm„ < [I SNIATA O POOLS TO A NO ISLAND OF AT LEAST 5O FEET ON— A - 'p [Y-,L STRATA OF TYPICAL LONG Il1J41D SAND AND GRAVEL \ Cl �E YNIw a g ZEST HOLE BY MCDONAID —SCIENCE,FEBRUARY 24,2020. ONO NO ELEVATION 360' i j1• INN4,Vo—t0"A- s3 XA x a t€ L.—-CL BROWN CIAMY SAND-SC 19' 22' BROWN CLAYEY SAND SO I EST . k 32'(EL 4.0') e.± WATER IN BROWN CLAYEY SAND-SC 110'r1_ 1 ' v�LL WATER IN BROWN FINE TO MEDIUM SANG-6P 11 41' A WATER ENCOUNTERED!Y BELOW SURFACE N N O #p6 nJ " DO 8 glBfEw Z S _.td6� T 13� tl Ri i�r'lgy+RE`Y,,i e �P n, 01 S TITLE NO 19-AS-55002 � 3 CERTIFIED 70 T/VIOL V 1 a .mv fi ACEva IrTUAONIAAGENCY.INC. �y [t T A.+J k°I:AT yAa TITLE INSURANCE COMPANY IµpROILD C! l m OTk 5 i S FILE 0—1340 1 " .: SCALE: 1"= 80' - DATE: JULY 11, 2019 MARCH 17.2020,BOH M MAY 11, 2020,REVISE PLAN DECEMBER 8,2020,SET STAKES,LOCATE SPRUCE ROW _ JANUARY 20,REVISE BUFFER REVISED SUBDIVISION MAP OF MINOR SUBDIVISION PLAT MADE FOR ROBERT T. C BAYLEY FILED DUNE 14,2016 AS MAP NO.A8I6 1 LOT AREA: 182,563.8 S0.FT.-4,19 ACRES - ° p PROPOSED BUILDING COVERAGE:(HOUSE W/OH'S,POOLHOUSE,SHEDS, i GARAGE)4,472.E S0.FT.-2.4% PROPOSED TOTAL LOT COVERAGE:15,524:6 SO.FT.-B 5% X PROPOSED CLEARING/SOIL DISTURBANCE:37,226-3 SO-FT. 20.4% A ELEVATIONS ARE N.A.V.D.1988 DATUM, Z LOCATION OF EXISTING SEPTIC AND WATER Fn SERVICE AS PER OWNER. -C U) O ss 6 SURVEY OF s aP 0 LOT 3 & _ 40' RIGHT OF WAY MAP OF K6 � ROBERT T. BAYLEY � \ SITUATE AT COLONIAL SURVEYING, PC SOUTHOLD JOSEPH SECCAFICO, PLS TOWN OF SOUTHOLD N.Y.S. LIC. NO. 050906 SUFFOLK COUNTY, NEW YORK 149 HAMPTON ROAD SOUTHAMPTON, NY 11968 S.C.T.M. 1000 - 59 - 7 - 29.5 PH 631-283-5500 COLONIALSUR VEYING®YAH OO.COM COPYRIGHT-2021 COLONIAL SURVEYING.PC A55CSSORS q 7 -;�q, r a GENERAL GUARDIAN® SERIES �6 k Residential Standby Generators Air-Cooled Gas Engine Standby Power Rating r INCLUDES: G007290-0 G007291-0 Aluminum-Bisque)-26 KW 60 Hz • True Power" Electrical Technology • Two-line multilingual digital LCD Evolution" controller (English/Spanish/French/Portuguese) • 200 amp service rated transfer switch available _ µ � • Electronic governor 4 ; • Standard Wi-Fi®connectivity • System status&maintenance interval LED indicators • Sound attenuated enclosure • Flexible fuel line connector • Natural gas or LP gas operation • 5 Year limited warranty • Base fascia'`- u, - • Listed and labeled for installation as close as 18 in(457 mm)to a - ° structure.* *Must be located away from doors,windows,and fresh air intakes and in ON usLISTEDor C �L USaccordance with focal codes. c Q�' O Note:CETL or CUL certification only applies to unbundled units and units packaged with limited circuit switches.Units packaged with the Smart Switch are ETL or UL certified in the USA only. .I FEATURES O INNOVATIVE ENGINE DESIGN&RIGOROUS TESTING are at the heart of Gen- O SOIIO-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This erac's success in providing the most reliable generators possible. Generac's G- state-of-the-art power maximizing regulation system is standard on all Generac mod- Force engine lineup offers added peace of mind and reliability for when it's needed els.It provides optimized FAST RESPONSE to changing load conditions and MAXI- the most.The G-Force series engines are purpose built and designed to handle the MUM MOTOR STARTING CAPABILITY by electronically torque-matching the surge rigors of extended run times in high temperatures and extreme operating conditions. loads to the engine.Digital voltage regulation at±1%. O TRUE POWER"ELECTRICAL TECHNOLOGY:Superior harmonics and sine wave O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network form produce less than 5%Total Harmonic Distortion for utility quality power.This provides parts and service know-how for the entire unit,from the engine to the small- allows confident operation of sensitive electronic equipment and micro-chip based est electronic component. appliances,such as variable speed HVAC systems. O TEST CRITERIA: O GENERAC TRANSFER SVITCHES:Long life and reliability are synonymous with ✓ PROTOTYPE TESTED ✓ NEMA M131-22 EVALUATION GENERAC POWER SYSTEMS.One reason for this confidence is that the GENERAC ✓ SYSTEM TORSIONAL TESTED ✓ MOTOR STARTING ABILITY product line is offered with its own transfer systems and controls for total system compatibility. O MOBILE LINK®CONNECTIVITY:FREE with select Guardian Series Home standby generators, Mobile Link Wi-Fi allows users to monitor generator status from any- where in the world using a smartphone,tablet,or PC.Easily access information such as the current operating status and maintenance alerts. Users can connect an account to an authorized service dealer for fast,friendly,and proactive service.With Mobile Link,users are taken care of before the next power outage. GENERAC Q@ 0 u PROMISE01e GENERAC4 26 kW Features and Benefits Engine • Generac G-Force design Maximizes engine"breathing"for increased fuel efficiency.Plateau honed cylinder walls and plasma moly rings help the engine run cooler,reducing oil consumption and resulting in longer engine life. • '`Spiny-lok"cast iron cylinder walls Rigid construction and added durability provide long engine life. • Electronic ignition/spark advance These features combine to assure smooth,quick starting every time. • Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance,less maintenance,and longer engine ' life.Now featuring up to a 2 year/200 hour oil change interval. • Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. • EPA Certified for non-emergency applications Allows unit to be used for demand response applications. • High temperature shutdown Prevents damage due to overheating. Generator • Revolving field Allows for a smaller,light weight unit that operates 25%more efficiently than a revolving armature generator. • Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. • Displaced phase excitation Maximizes motor starting capability. • Automatic voltage regulation Regulating output voltage to ±1%prevents damaging voltage spikes. • UL 2200 listed For your safety. Transfer Switch(if applicable) • Fully automatic Transfers vital electrical loads to the energized source of power. • NEMA 311 Can be installed inside or outside for maximum flexibility. • Integrated load management technology Capability to manage additional loads for efficient power management. • Remote mounting Mounts near an existing distribution panel for simple,low-cost installation. Evolution— Controls • AUTO/MANUAUOFF illuminated buttons Selects the operating mode and provides easy,at-a-glance status indication in any condition. • Two-line multilingual LCD Provides homeowners easily visible logs of history,maintenance,and events up to 50 occurrences. • Sealed,raised buttons Smooth,weather-resistant user interface for programming and operations. • Utility voltage sensing Constantly monitors utility voltage,setpoints 65%dropout,80%pick-up,of standard voltage. • Generator voltage sensing Constantly monitors generator voltage to verify the cleanest power delivered to the home. • Utility interrupt delay Prevents nuisance start-ups of the engine,adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer. • Engine warm-up Verifies engine is ready to assume the load,setpoint approximately 5 seconds. • Engine cool-down Allows engine to cool prior to shutdown,setpoint approximately 1 minute. • Programmable exercise Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week. Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel costs to the owner. • Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM-style batteries. • Main line circuit breaker Protects generator from overload. • Electronic governor Maintains constant 60 Hz frequency. Unit • SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature, withstanding winds up to 150 mph(241 km/h).Hinged key locking roof panel for security.Lift-out front for easy access to all routine maintenance items.Electrostatically applied textured epoxy paint for added durability. • Enclosed critical grade muffler Quiet,critical grade muffler is mounted inside the unit to prevent injuries. • Small,compact,attractive Makes for an easy,eye appealing installation,as close as 18 in(457 mm)away from a structure. r 4 GENERAC' 26 kW Features and Benefits Installation System s 14 in(35.6 cm)flexible fuel line connector Listed ANSI Z21.75/CSA 6.27 outdoor appliance connector for the required connection to the gas supply piping. • Integral sediment trap Meets IFGC and NFPA 54 installation requirements. Connectivity(NVi-1-i equipped models only) • Ability to view generator status Monitor generator with a smartphone,tablet,or computer at any time via the Mobile Link application for complete peace of mind. 0 Ability to view generator Exercise/Run and Total Hours Review the generator's complete protection profile for exercise hours and total hours. • Ability to view generator maintenance information Provides maintenance information for the specific model generator when scheduled maintenance is due. • Monthly report with previous month's activity Detailed monthly reports provide historical generator information. • Ability to view generator battery information Built in battery diagnostics displaying current state of the battery. • Weather information Provides detailed local ambient weather conditions for generator location. Y GENERAL 26 kW Specifications Generator Model G007290-0 G007291-0 (26 kW) Rated maximum continuous power capacity(LP) 26,000 Watts` Rated maximum continuous power capacity(NG) 22,500 Watts" Rated voltage 240 Rated maximum continuous load current—240 volts(LP/NG) 108.3/93.8 Total Harmonic Distortion Less than 5% Main line circuit breaker 110 amp Phase 1 Number of rotor pales 2 Rated AC frequency 60 Hz Power factor 1.0 Battery requirement(not included) 12 Volts,Group 26R 540 CCA minimum or Group 35AGM 650 CCA minimum_ Unit weight(lb/kg) 518/235 Dimensions(L x-W x H)in/cm 4B x 25 x 29/121.9 z 63.5 x 73.7 Sound output in dB(A)at 23 ft(7 m)with generator operating at normal load" 67 Sound cutpu(in dB(A)at 23_111(7 m)with generator in Quiet-TestV'low-speed exercise mode" 57- Exercise duration 5 min Engine Engine type GENERAC G-Force 1000 Series Number of cylinders ; 2 Displacement 999 cc Cylinder block Aluminum W/cast iron sleeve. Valve arrangement Overhead valve Ignition system Solid-state w/magneto Governor system Electronic Compression ratio ; 9.5:1 Starter 12 VDC Oil capacity including filter. A pprox 1.9 gt11.8 L Operating rpm 3,600 Fuel consumptlab Natural gas 113/hr(m3/hr) 188(5:32) 1/2 Load, Full Load - 333(9.43) Liquid propane ft3/hr(gal/hr)[L/hrJ 75(2.06)"[7.78] Full Load 1/2 Load 1 (3.63).[73:73] Note:Fuel pipe must be sized for lull load.Required fuel pressure to generator fuel inlet at all load ranges-3.5-7 in water column(0.87-1.74 kPa)for NG,10-12 in water column(2:49-2.99 kPa)for LP gas. For BTU content,multiply 113/hr x 2500(LP)or ft3/hr x 1000(NG).For Megajoule content,multiply m3/hr x 93.15(LP)or m3/hr x 37.26(NG). Controls Two-line plain text multilingual LCD Simple user interface for ease of operation. Mode hultoris:AUTOr Automatic staff on utility failure..Weekly,Bi-weekly,or Monthly selectable exerciser. MANUAL Start with starter control,unit stays on.If utility fails,transfer to load takes place. OFF Stops unit:Power is removed.Control and charger still operate. Ready to Run/Maintenance messages Standard Engine mn hours indication Standard Programmable start delay between 2-1500 seconds Standard(programmable by dealer only) Utility Voltage Loss/Return lo'Utilily adjustable(brownout setting) From 140-171 V/190-216 V Future Set Capable Exerciser/Exercise Set Error warning Standard RurvAlatin/Maintenance logs - 50 events each Engine start sequence Cyclic cranking:16 sec on,7 rest(90 sec maximum duration). Starter lock-but Starter cannot re-eogag_e until 5 sec after engine has stopped. Smart Battery Charger Standard Charger Fault/Missing AC warning Standard_ Low Battery/Battery Problem Protection and Battery Condition indication Standard Automatic Voltage Regulation with Over and Under Voltage Protection Standard . Under-Frequency/Overload/Stepper Overcurrent Protection Standard Safety Fused/Fuse Problem Protection Standard" " Automatic Low Oil Pressure/High Oil Temperature Shutdown Standard OvercranWOverspeed(@ 72 Hi)/rpm Sense Loss Shutdown . - Standard High Engine Temperature Shutdown Standard Internal FaulNncofrect Wiring protection Standard Common external fault capability Standard Field upgradible himvrare Standard " Rating definitions—Optional Standby:Applicable for supplying backup power for the duration of the utility power outage with correct maintenance performed. 'No overload capability is available for this rating.(All ratings in accordance with BS5514,ISO3046,UL2200,and DIN6271).Maximum kilovolt amps and current are subject to and limited by such factors as fuel BTU/Megajoule content,ambient temperature.attitude,engine power and condition,etc.Maximum power decreases approximately 3.5%for each 1,000 it(304.8 m)above sea level and approximately 1% for each 10'F(6'C)above 60"F(16`C)."`Sound levels are taken from the front of the generator.Sound levels taken from other sides of the generator may be higher depending on installation parameters. U.S.EPA certified for non-emergency applications. GENERAC� 26 kW Switch Options Service Rated Automatic Transfer Switch Features Model G007291-0(26 kW) • Intelligently manages up to four air conditioner loads with no additional hardware. No.of poles 2 Current rating(amps) 200 • Up to eight additional large(240 VAC)loads can be managed when used in conjunction Voltage rating(VAC) 120/240,10 with Smart Management Modules(SMMs). utility voltage monitor(fixed) • Electrically operated,mechanically-held contacts for fast,clean connections. -Pick-up 80% -Dropout 65"6 • Main breakers are rated for 80%continuous load. Return to utility Approx.l3sec • 2-pole,250 VAC contactors. ErL or UL listed Standard • Service equipment rated,dual coil design. Enclosure type NEMA/UL 3R Circuit breaker protected 22,000 • Rated for both aluminum and copper conductors. Lug range 250 MCM #6 • Main contacts are silver plated or silver alloy to resist welding and sticking. *Function of Evolution controller • NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility. Exercise can be set to weekly,bi-weekly,or monthly w+ Dimensions 200 Amps 120/240,1e I Open Transition Service Rated Height Width Depth H1 H2 Wi W2 az H+ in 26.8 30.1 10.5 13.5 6.9 cm 1 67.95 76.43 26.67 34.18 17.5 Wire Ranges Conductor Lug Neutral Lug Ground Lug L 250 MCM-#6 350 MCM-#6 2/0-#14 r GENERAL' 26 W Available Accessories Model# _Product, Description G007101-0 Battery Pad Warmer Pad warmer rests under the battery.Recommended for use if temperature regularly falls below 0°F(-18°C).(Not nec- essary for use with AGM-style batteries). G007102-0 Oil Warmer Oil warmer slips directly over the oil filter.Recommended for use if temperature regularly falls below 0°F,(-18°C). G007103-1 Breather Warmer Breather warmer is for use in extreme cold weather applications.For use with Evolution controllers only in climates where heavy icing occurs. G005621-0 Auxiliary Transfer Switch The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load that may not be Contact Kit needed.Not compatible with 50 amp pre-wired switches. G007027-0-Bisque Fascia Base Wrap Kit The fascia base wrap snaps together around the bottom of the new air-cooled generators.This offers a sleek,contoured appearance as well as offering protection from rodents and insects by covering the lifting holes located in the base. G005703-0-Bisque Touch-Up Paint Kit If the generator enclosure is scratched or damaged,it is important to touch up the paint to protect from future corrosion. The touch-up paint kit includes the necessary paint to correctly maintain or touch up a generator enclosure. 6006485-0 Scheduled Maintenance Kit Generac's scheduled maintenance kit provides all the items necessary to perform complete routine maintenance on a Generac automatic standby generator(oil not included). 13007005-0 Wi-Fi LP Tank Fuel Level The Wi-Fi enabled LP tank fuel level monitor provides constant monitoring of the connected LP fuel tank.Monitoring the Monitor LP tanks fuel level is an important step in verifying the generator is ready to run during an unexpected power failure.Sta- tus alerts are available through a free application to notify users when the LP tank is in need of a refill. G007000-0(50 amp) Smart Management Module Smart Management Modules(SMM)are used to optimize the performance of a standby generator.It manages large elec- G007006-0 trical loads upon startup and sheds them to aid in recovery when overloaded.In many cases,using SMM's can reduce (100 amp) the overall size and cost of the system. G007169-0-413 LTE Mobile Link Cellular The Mobile Link family of Cellular Accessories allow users to monitor generator status from anywhere in the world,using G007170-0-Wi-Fi/ Accessories a smart phone,tablet,or PC.Easily access information such as the current operating status and maintenance alerts.Us- Ethernet ers can connect an account with an authorized service dealer for fast,friendly,and proactive service.With Mobile Link, users are taken care of before the next power outage. dO07220-0-Bisque Base Plug Kit Base plugs snap into the lifting holes on the base of air-cooled home standby generators.This offers a sleek,contoured appearance,as well as offers protection from rodents and insects by covering the lifting holes located in the base.Kit contains four plugs,sufficient for use on a single air-coaled home standby generator. Dimensions & UPCs Model UPC 63" 'Al 218 mm [25.1 l [68.0 ml G007290-0 696471087307 G007291-0 696471087314 727.2 mm (26.61.1 o a o 0 648 mm 1232 mm [25.5 inl [46.5 inl LEFT SIDE VIEW FRONT VIEW Dimensions shown are approximate.See installation manual for exact dimensions.DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. GENE RAC' Generac Power Systems,Inc. • S45 W29290 HWY.59,Waukesha,WI 53189 • generac.com ©2022 Generac Power Systems,Inc.All rights reserved.All specifications are subject to change without notice. Part No.A0002026894 Rev.0 04/26/2022