Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
51178-Z
X%oF soolyo6 Town of Southold * * P.O. Box 1179 53095 Main Rd Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 46100 Date: 04/10/2025 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 710 Waterview Dr Southold, NY 11971 Sec/Block/Lot: 78.-7-30 Conforms substantially to the Application for Building Permit heretofore,filed in this office dated: 07/26/2024 Pursuant to which Building Permit No. 51178 and dated: 09/12/2024 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: Roof-mounted solar panels to an existing single-family dwelling as applied for. The certificate is issued to: Suzanne Valenza , Sherry Valenza Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: 51178 4/8/2025 PLUMBERS CERTIFICATION: A t uriz d Signature aoFsoulyo TOWN OF SOUTHOLD 6 BUILDING DEPARTMENT ' TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 51178 Date: 09/12/2024 Permission is hereby granted to: Suzanne Valenza 710 Waterview Dr Southold, NY 11971 To: Install roof mounted solar panels to an existing single-family dwelling as applied for. Premises Located at: 710 Waterview Dr, Southold, NY 11971 SCTM#78.-7-30 Pursuant to application dated 07/26/2024 and approved by the Building Inspector. To expire on 03/14/2026. Contractors: Required Inspections: Fees: SOLAR PANELS $100.00 CERTIFICATE OF OCCUPANCY' $100.00 ELECTRIC -Residential $125.00 Total S325.00 Building Inspector o��pF SOUj�ol . � o Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 G Q Southold,NY 11971-0959 Jamesh southoldtownny.gov UT`I BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Suzanne Valenza Address: 710 Waterview Drive city:Southold st: New York zip: 11971 Building Permit#: 51178 Section: 78 Block: 7 Lot: 30 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Sunation Solar System: Electrician: Scott Maskin License No: 33412-ME SITE DETAILS Office Use Only Residential X Indoor . X Basement Service Commerical Outdoor X 1st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures Sump Pump Other Equipment: 9.24kw roof mounted pv solar energy system with 22 panels[ REC420AA PURE 2 ] 22 micro inverters[ IQ8A-72-2-US ] , 1 enphase combiner panel, 1 40amp a/c disconnect Notes: SOLAR ENERGY SYSTEM Inspector Signature: Date: April 8, 2025 71 Orwaterview dr oF So�lyo�o 6l 1746 7/0 WoJer v c� # # TOWN OF SOUTHOLD BUILDING DEPT. cou�+� 631-765-1802 ANSPECTION [ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE.RESISTANT CONSTRUCTION: [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS. c__�® /0-r (�rptcts A-eLdrcd e-etyk pio� be- kovd-ed IAQL_5c_6c4rnpC4M&UvL DATE 3 I o�-�J INSPECTOR q SOGTh°� * # TOWN OF SOUTHOLD BUILDING DEPT. o � 631-765-1802 IN S P E CTI O N [ ] FOUNDATION 1ST/ REBAR [ ']' ROUGH PLBG. [ ] FOUNDATION 2ND- [ ] SULATION/CAULKING [ ] FRAMING /STRAPPING [ .FINAL�014_k [ ] FIREPLACE & CHIMNEY- [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) . [ ] ELECTRICAL-(FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL RE ARKS: �J&�V, ' nn � 41� Um Ala fTh_ N�f r�P( 4-C, 6-V LCk* D l ' DATE INSPECTOR �✓ of . ra I a m.yew s � .z. "!.y,!�,.�- 4 sY"�"��i l2ea• 4 ., ♦• �ai"S'�•'" `j .•t i � t r a. ,i,.v.j�?. ''` �L y.. l'4' 4_V l 1 - -�. .i rn 1 uS�r`��,�x�,< t o �, �d r h Y•, oll .! — r � OS y Orr, :nil L`n/1 40 40 111 I �i 111�f � 7 J, a i j. FIELD INSPECTION REPORT DATE COMMENTS FOUNDATION (1ST) ------------------------------------ C FOUNDATION (2ND) O H ROUGH FRAMING& �0- PLUMBING v w Q r INSULATION PER N.Y. y STATE ENERGY CODE FINAL i ADDITIONAL COMMENTS t ell so z m C(' � -1 3 t� b � H � z x E� x d b H o�g�fFOtt�oG TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 r�ia x Telephone(631) 765-1802 Fax (631) 765-9502 https://www.southoldtownny.gov Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only D C r� E f, i PERMIT NO. v 079 Building Inspector: j JUL 2 6 2024 Applications and forms must be filled out in their'entirety.Incomplete " applications will not be accepted. Where the Applicant is not the owner,an Owner's Authorization form(Page 2)shall be completed.- Buildiin� !3eg?artrbie9it Town of Southoid Date: ?(a3 a OWNER(S)OF PROPERTY: Name:Suzanne Valenta SCTM#1000-78-7-30 Project Address:710 Waterview Dr, Southold, NY 11971 Phone#:631-921-0854_ _ _ Email_suevalenza@g_mail.com Mailing Address:710 Waterview Dr, Southold, NY 11971 CONTACT PERSON: Name_ Evelyn Polvere/Sunation Solar Systems Mailing Address: 171 Remington Blvd., Ronkonkoma, NY 11779 Phone#: 631-750-9454 ext 346 Email: i ingasunation.com_ _ DESIGN PROFESSIONAL INFORMATION: Name:Michael Dunn, Graham and Associates -Inc. Mailing Address:256A Orinoco Drive, Brightwaters, NY 11718 _ Phone#:631-665-9120 Email:glenn@grahamassociatesny.com CONTRACTOR INFORMATION: Name:Scott Maskin/Sunation Solar Systems Mailing Address:171 Remington Blvd.,_ Ronkonkoma, NY 11779 Phone#: 31- 50-9454 _p-- 67 Email: ermittin sunation,com - ---- - - --- --. - g@- - DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ®Alteration ❑Repair ❑Demolition Estimated Cost of Project: ❑Other $ �k`1�960.00 Will the lot be re-graded? ❑Yes ®No Will excess fill be removed from premises? ❑Yes RNo 1 PROPERTY INFORMATION Existing use of property:Residential Intended use of property: Residential Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes ®No IF YES,PROVIDE A COPY. ❑Check Box After Reading: The owner/contractor/design professional is responsible for all.drainage and storm water issues as.provided by - Chapter 236 of the Town Code.APPLICATION IS HEREBY MADE to'the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described:The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises'and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanorpursuant to Section 210.45 of,the.New York State Penal Law. Application Submitted By(print name . Cott Maskin BAuthorized Agent ❑Owner Signature of Applicant: Date: STATE OF NEW YORK) SS: COUNTY OF Suffolk ) Scott Maskin being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Contractor (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this _day of ��A 20 a y 1 Notary Public LYNN VRA Notary Public,State of Nam► Registration #'O1V1 KY PROPERTY OWNER AUTHORIZATION Qualified in SuffolK Gou My Commiselon Explres Got.A --I- (Where the applicant is not the owner) I, Suzanne Valenza residing at 710 WatervieW Drive Southold do hereby authorize Scott Maskin to apply on my beh If to the Town o Southold Building Department for approval as described herein. Ldu —--t— l 4 ner's Signature bate Suzanne Valenza Print Owner's Name 2 SSE BUILDING DEPARTMENT-Electrical Inspector TOWN OF SOUTHOLD o Town Hall Annex - 54375 Main Road - PO Box 1179 o ` ProSouthold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 rogerr@southoldtownny.gov�sea ndCcD-southoldtownn ..gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All information Required) Date: Company Name: SUNation Solar Systems, Inc Name: Scott Maskin License No.: 33412-ME email: permittingasunation.com Address: 171 Remington Blvd. Ronkonkoma NY 11779 Phone No.: 631-750-9454 JOB SITE INFORMATION (All information Required) Name: _ Suzanne Valenza ? Address: 710 Waterview Dr. Southold NY 11971 Cross Street: Phone No.: 631-921-0854 Bldg.Permit#: 511718 email: suevalenza mail.com Tax Map District: 1000 Section: 78 Block: 7 Lot: 30 BRIEF DESCRIPTION OF WORK(Please Print Clearly) Installation of solar panels - flat on roof Circle All That Apply: Is job ready for inspection?: YES / NO Rough In Final Do you need a Temp Certificate?: YES / NO Issued On Temp Information: (All information required) Service Size 1 Ph 3 Ph Size: A #Meters Old Meter# . New Service - Fire Reconnect- Flood Reconnect-Service Reconnected-Underground - Overhead #Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION Request for Inspection Formals APPROVED AS NOTED DATE:C7L 12 24 B.P.# 51 t I g FE a0D.00 BY: COMPLY WITH&L CODES OF NEW YORK STATE&TOWN CODES NOTIFY BUILDING DEPARTMENT AT AS AND CONDIMONS OF 631 Z 65-1802 8AM TO 4PM FOR THE mmmmzm FOLLOWING INSPECTIONS: mmmRmsm FOUNDATION-TWO REQUIRED mjR m FOR POURED CONCRETE 1mew ROUGH-FRAMING&PLUMBING INSULATION FINAL-CONSTRUCTION MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS ELECTRICAL INSPECTION REQUIRED Additional Certification May Be Required. chi wonlnec,4 mud- be, loccrkd pu4side 1 a►ocled and geoid i Lj acCesstlo�e . 1 i l Graham Associates 256 Orinoco Drive, Suite A Brishtwaters,NY 11718 Planning& Design (631)665-9619 July 23, 2024 Town of Southold Building Department 54375 Rt. 25 Southold, NY 11971 Re: Valenza Residence 710 Waterview Drive Southold, NY Proposed 9.24 KW PV System To Whom It May Concern, Please be advised that I have analyzed the existing roof structure at the above-mentioned premises and have determined that it is adequate to support the additional load of the solar panels and a 140 mph wind load and 20 psf snow load without overstress, in accordance with the following: The 2020 New York State Uniform Fire Prevention and Residential Building Code; Town of Southold Local Code, Long Island Unified Solar Permit Initiative, (LIUSPI); and 2020 National Electric Code NFPA 70/2020 National Electric Code including ASCE7-16 If you have any further questions, do not hesitate to call. ?�®g� . 4,51 C/ Cf) °� Ab unn, RA o a /* SOLAR'S MOST TRUSTED ® REC AL mm. 0 Ff COMPACT PANEL SIZE �a � r EXPERIENCE WP . 430 REC 25 YEAR 20.6 FT2 WARRANTY �O 22.20 EFFICIENCY LEAD-FREE ELIGIBLE ROHS COMPLIANT PERFORMANCE REWLPHA PURE 2 SER166 REC PRODUCT . • MOST • 73A±0.1 GENERAL DATA � _ _.._.: �_ 36A±0.1 _ 18.530.1 Cell type: 132 half-cut REC heterojunction cells with lead-free, 6.05 gapless technology,6 strings of 22 cells in series 0.12 in solar glass with anti-reflective surface treatment492 Glass: in accordance with EN 12150 L+f Backsheet: Highly resistant polymer(black) 0.24±0.01 Frame: Anodized aluminum(black) s Junction box: 3-part,3 bypass diodes,lead-free Q IP68 rated,in accordance with IEC 62790' Staubli MC4 PV-KBT4/KST4(12 AWG) 0.4330.01 Connectors: in accordance with IEC 62852,1P68 only when connected Cable: 12AWG solar cable,49.2+49.2in 0.8±0.02 in accordance with EN50618 ass 011 6.05 ' Dimensions: 73.4x40.9x1.2in(20.88sq-ft) f Weight: 47.6lbs(21.6 kg) r-- 1 8 0.9 273±0.1 Origin: Made in Singapore M 1.2 Measurements in inches[mm) ELECTRICAL DATA Product Code*-RECxxxAA PU_RE 2_, _� CERTIFICATIONS' Power Output-PMAx(Wp) 400 410 _ 420 430 IEC 61215:2016,IEC 61730:2016,UL 61730 Watt Class Sorting-(W) 0/+10 0/+10 0/+10 0/+10 IEC62804 PID IEC 61701 Salt Mist Nominal PowerVoltage-VMPP(V) 41.1 41.6 42.2 42.8 IEC62716 Ammonia Resistance U Nominal Power Current-IMPP(A) 9.74 9.86 9.96 10.05 UL61730 Fire Type 2 rn Open Circuit Voltage-V0C(V) 48.5 48.8 49.1 49.3 IEC62782 Dynamic Mechanical Load IEC 61215-2:2016 Hailstone(35mm) Short Circuit Current Isc(A) 10.60 10.67 10.74 10.81 IEC62321 Lead-freeacc.to RoHS EU 863/2015 Power Density(W/ft2) 19.2 19.6 20.1 20.6 ISO14001,ISO 9001,IEC 45001,IEC 62941 Panel Efficiency(%) 20.6 21.1 21.7 22.2 o�E D- C E � � Power Output-PMAx(Wp) 304 312 320 327 Wenck Lead+ae F_ Nominal Power Voltage-VMPP(V) 38.7 39.2 39.8 40.3 pTEMPERATURERATINGS* - % 6 Nominal Power Current-IMPP(A) 7.86 ' 7.96 8.05 8.12 Nominal Module OperatingTemperature: 44°C(±2°C) Z Open Circuit Voltage-Vol(V) 45.7 45.8 46.0 46.2 Temperature coefficient ofPMAx: -0.24%/°C o Short Circuit Current-Isc(A), 8.50- 8.62 8.68 8.73 Temperature coefficient ofVOC: -0.24%/°C 3 ( /G / ) P ( ) P P o Valuesatstandardtestconditions STC:airmassAMlS,irradian[e10.75W s ft(1DOOW m',tem erature77°F 25°C,basedona production read Temperature coefficient oflsc: 0.04//°C with a tolerance of P_V,&I,±3%within onewatt class.Nominal module operating temperature(NMOT:air mass AM I.S.irradiance 800 W/m� -6 temperature 68°F(20°C),windspeed33ft/s0rn/s).•Wherexl indicatesthe nominal power class(P".)atSTCabcve. 'The temperature coefficients stated are linearvalues E .MAXIMUM RATINGS WARRANTY _ �_ DELIVERY INFORMATION Operational temperature: -40...+85°C Standard REC ProTrust Panels per pallet: 33 co Systemvoltage: 1000V Installed byan REC No Yes Yes Panels per40 ftGP/high cube container: 792(24 pallets) w Certified Solar Professional - Test load(front): +7000 Pa(1461bs/ft2)' System Size All s25 kW 25 500 kW Panels per 53 ft truck: 858(26 pallets) N Test load(rear): -4000Pa(83.5lbs/ft2)' Product Warranty(yrs) 20 25 25 Series fuse rating: 25 A Power Warranty(yrs) 25 25 25 SLOW LIGHT BEHAVIOUR m Reverse current: 25A Labor Warranty(yrs) 0 25 10 Typical low irradiance performance of module atSTC: See installation manual for mounting instructions. Power in Year] 98% 98% 98% a Design load=Test load/1.5(safetyfactar) Annual Degradation 0.25% 0.25% 0.25% Power inYear25 92% 92% 92% °---- --r--------i--------1-------- a w o See war ra nty d o cum en ts fo r d e tail s.C on diti o ns a p ply " .........'-------'-------- ......... d a m m w m Available from: Irradlance(W/m') Founded in'1996,RECGroup is an international pioneering solar energy company dedicated to empowering consumers REC Solar PTE.LTD. ��` with clean,affordable solar power.As Solar's Most Trusted,REC is committed to high quality,innovation,and a low 20TuasSouthAve.14 s carbon footprint in the solar materials and solar panels it manufactures.Headquartered in Norway with operational Singapore 637312 headquarters in Singapore,REC also has regional hubs in North America,Europe,and Asia-Pacific. post@recgroup.com www.recgroup.com • o ENPHASE, ENPHASE IBM , INC A IQBM and IQBA Microinverters Our newest IQ8 Microinverters are the industry's first microgrid-forming,software defined Easy to install microinverters with split-phase power conversion capability to convert DC power to AC Lightweight and compact with plug-n- power efficiently.The brain of the semiconductor-based microinverter is our proprietary play connectors application specific integrated circuit(ASIC)which enables the microinverter to operate in grid-tied or off-grid modes.This chip is built in advanced 55nm technology with high speed Power Line Communication(PLC) digital logic and has superfast response times to changing loads and grid events,alleviating between components constraints on battery sizing for home energy systems. Faster installation with simple two-wire cabling ` Enphase High productivity and reliability • Produce power even when the grid is i ,- 5 down' • More than one million cumulative hours ' Part of the Enphase Energy System,I08 IQ8 Series Microinverters redefine of testing Series Microinverters integrate with the reliability standards with more than one Class II double-insulated enclosure IQ Battery,10 Gateway,and the Enphase million cumulative hours of power-on Optimized for the latest high-powered App monitoring and analysis software. testing,enabling an industry-leading PV modules limited warranty of up to 25 years. Microgrid-forming • Complies with the latest advancedgrid support" VIEW ""Oftow CERTIFIED Remote automatic updates for the latest grid requirements Connect PV modules quickly and easily IQ8 Series Microinverters are UL listed Configurable to support a wide range to IQ8 Series Microinverters using the as PV Rapid Shutdown Equipment and of grid profiles included Q-DCC-2 adapter cable with conform with various regulations,when Meets CA Rule 21(UL 1741-SA)and IEEE plug-n-play MC4 connectors. installed according to manufacturer's 1547:2018(UL 1741-SB 3rd Ed.) instructions. Note: IQ8 Microinverters cannot be mixed together with . previous generations of Enphase microinverters 007 *Only when Installed with IQ System Controller 2,meets UL 1741. Series,IQ6 Series,etc)In the same system. ••IQBM and IQBA support split-phase,240V installations only. ©2022 Enphase Energy.All rights reserved.Enphase,the Enphase logo,I08 Microinverters, and other names are trademarks of Enphase Energy,Inc.Data subject to change. IQBMA-I2A-DS-0069-03-EN-US-2022-12-27 A IQBM and IQBA Microinverters INPUT DATA r Commonly used module pairings' W 260-460 I 295-500 Module compatibility 54-cell/108 half-cell,60-cell/120 half-cell,66-cell/132 half-cell and 72-cell/144 half-cell MPPT voltage range V 30-45 32-45 Operating range V 16-58 Min./Max.start voltage V 22/58 Max.input DC voltage V 60 I Max.continuous input DC current A 12 Max.input DC short-circuit current A 25 Max.module I. A 20 Overvoltage class DC port II DC port backfeed current mA 0 PV array configuration 1 x 1 Ungrounded array;No additional DC side protection required;AC side protection requires max 20A per branch circuit OUTPUT 1 1 0 Peak output power VA 330 366 Max.continuous output power VA 325 349 Nominal(L-L)voltage/range V 240/211-264 Max.continuous output current A 1.35 1.45 I Nominal frequency Hz 60 Extended frequency range Hz 47-68 AC short circuit fault current over 2 3 cycles Arms Max.units per 20 A(L-L)branch circuit' 11 Total harmonic distortion <5% Overvoltage class AC port III AC port backfeed current mA 30 Power factor setting 1.0 Grid-tied power factor(adjustable) 0.85 leading-0.85 lagging Peak efficiency % 97.8 97.7 CEC weighted efficiency % 97.5 97 Night-time power consumption mw 60 MECHANICAL DATA Ambient temperature range I -40°C to+60°C(-40oF to+140°F) Relative humidity range 4%to 100%(condensing) DC Connector type I MC4 Dimensions(H x W x D) 212 mm(8.3")x 175 mm(6.9")x 30.2 mm(1.2") Weight j 1.08 kg(2.38lbs) Cooling Natural convection-no fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double-insulated,corrosion resistant polymeric enclosure Environ.category/UV exposure rating NEMA Type 6/outdoor ' CA Rule 21(UL 1741-SA),UL 62109-1,IEEE 1547:2018(UL 1741-SB 31°Ed.),FCC Part 15 Class B,ICES-0003 Class B,CAN/CSA-C22.2 NO.107.1-01 Certifications This product is UL Listed as PV Rapid Shutdown Equipment and conforms with NEC 2014,NEC 2017,and NEC 2020 section 690.12 and C22.1- 2018 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according to manufacturer's instructions. (1)Pairing PV modules with wattage above the limit may result in additional clipping losses.See the compatibility calculator at https://Iink.enphwe.com/module-compatibility.(2)Nominal voltage range can be extended beyond nominal If required by the utility. (3)Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. IOSMA-I2A-DS-0069-03-EN-US-2022-12-27 SERIES 100 ROOF MOUNT SnapNiracl Sola, • • So ulions The SnapNrack line of solar mounting solutions is designed to reduce total installation costs. The system's technical innovations have been proven to drive down costs and improve installation quality on more than 350 MW of solar �- installations. Pitched Roof Arrays Simplified rQ ya ^y� The SnapNrack Series 100 UL Roof Mount System 4 ,'M is an efficient,visually appealing, photovoltaic (PV) module installation system. Series 100 UL is Listedto the UL Standard 2703 for Bonding, meaning that all system components have been Certified by UL for Roof System in 4 Simple Steps: electrical continuity, eliminating the need for additional 1) Go to the online Series 100 Configuration grounding hardware.The System's components provide Tool (configure.snapnrack.com) and select an adequate bonding path which has eliminated the "Yes" for UL 2703 Listed need for grounding lugs and washers at each module, and bonding jumpers between splices. The UL 2703 2) Identify Site Conditions (Array Tilt, Building Listing ensures that SnapNrack partners can provide Height, Roof Type, Wind and Snow Loads) the best in class installations in quality, safety,and 3) Build array in the online Configuration efficiency. Tool and automatically generate a Bill of Materials. • All bonding hardware is fully integrated into the components 4) Place order with your distributor. Purchase material for a single project or order in bulk • No grounding lugs required for modules I for additional savings • Rail splices bond rails together, no rail jumpers required • Proprietary SnapNrack grounding lug snaps in the rail channel, no drilling of rail or reaching for other tools required (One Lug per individual row of modules) U • Class A Fire Rating Type 1 and 2 modules O` LISTED PV Mounting System Patent Pending 2703 Stainless Bolt with Stainless Steel apNrack Banding SnapNrack Standard Rail Split-Lock Washer Bolt with Split- Splice Insert Lock Washer SnapNrackBonding 2,�,Sn SnapNrack Adjustable End SnapNrack -yt Splice Clamp Top Bonding Base Mid Clamp SnapNrack SnapNrack Bonding Bonding SnapNrack Adjustable End Stainless Channel Nut Clamp Bottom Bonding Stainless Hardware with Bolt with Channel Nut Split-Lock Washers Split Lock SnapNrack Bonding SnapNrack Bonding Washer Adjustable End Clamp p 9 SnapNrack Bonding Mid Clamp Standard Rail Splice SnapNrack Ground Lug 10-6 AWG Copper Wire SnapNrack Ground Lug Assembly ONE REQUIRED PER ROW OF • MODULES) SnapNrack Bonding Universal End Clamp(UEC)Wave UEC Pull Strap UEC Wedge Stainless Steel Bolt with Flat Washer IF IF F IF IF IF SnapNrack Bonding Universal End Clamp SnapNrack Bonding "� Standoff �� Clamp Assembly SnapNrack Serrated Stainless SnapNrack SnapNrack Bonding Rubber Steel Flange Nut Bonding Channel Nut Channel Stainless Rain Collar Serrated Stainless Nut Flange Nut Steel Flange Bolt SnapNrack • Stainless SnapNrack �� 92 Degree Flange Mill Finish L Foot Bolt Standoff - SnapNrack SnapNrack All Purpose Mill Finish L Foot Standoff Base(1-Hole SnapNrack SnapNrack Base Shawn) SnapNrack L Foot Metal Roof Mill Finish Flashing Base Assembly L Foot Base SnapNrack Bonding SnapNrack Bonding SnapNrack Metal Standoff Assembly L Foot Base with Flashing Roof Base with Bonding L Foot SnapNrack • • UL Technical Data Materials • 6000 Series aluminum • Stainless steel • Galvanized Steel and Aluminum Flashing Material Finish •Clear and black anodized aluminum •Mill Finish on select components Installation •Quick and efficient mounting •Adjustable hardware to ensure clean and level finish •All components bonded to ground with integrated bonding features Calcs. &Certifications • Listed to UL Standard 2703 for Grounding/Bonding and Fire Classification • Class A Fire Rating Type 1 and Type 2 Modules • Stamped Structural Engineering Reports for all 50 States Grounding • SnapNrack Grounding Lug (One Lug per individual row of modules) Warranty • 10 Year material and worksmanship (download full details at snapnrack.com) SnapNrack- Solar Mounting Solutions (877) 732-2860 www.SnapNrack.com 0 Printed on recycled paper using soy based inks. ©2015 by SnapNrack PV Mounting System.All rights reserved. SER, IES 100 FLASHED L FOOT Sn.apN,8cl Residenlial PV Mounlin-g The SnapNrack line of solar mounting ��; �T}n ;'rF Yr 7 % 1 i systems is.designed to reduce total installation costs. The system features technical innovations proven on more than 200MW of solar projects to.simplify. installation and reduce costs. Flashed L Foot Simplified SnapNrack Series 100 Flashed L Foot Kit is an innovativeQ solution to provide a long lasting watertight seal over a t the life of the system.The Flashed L Foot provides a single fastener flashed to an attachment composition Flashed L Foot in 3.Simple Steps: shingle roof with no required cutting of shingles.The L 1) Locate the rafter and drill the pilot hole Foot is engineered for maximum adjustability for a clean level installation. 2) Prep and attach the base 3) Set the flashing and attach the L Foot • 1"slotted bolt connection • 1"spacers available for increased adjustability • Clear or Black anodized aluminum components Place order through your SnapNrack (both available with black flashing) distributor, which can be found at • No Cutting of shingles www•snapnrack.com/contact SnapNrack- Patent Pending py M®Unu n g zVoUmn - I 1 I r4 'J• $ - 1 Flashed L Foot Kit Assembled(1'spacer sold separately) Flashed L Foot Kit Parts(1"spacer sold separtely) Flashed L Foot Kit Assembly Flashed L Foot Kit Dimensions rSNAPNRACK CHANNEL NUT E rSNAPNRACK 92 DEGREE L-FOOT,CLEAR .-5/1618 FLANGE NUT 9 / �5/I6-18 X IIN BOLT WITH SKIT 1.WASHER .-SNAPNRACK COMPOSITION FLASHING \4' 3.13 `SNAPNRACK L-FOOT BASE SnapNrack Flashed • • Tech nicalData Patent Pending Materials 6000 Series Aluminum L Foot&Base Stainless Steel Hardware Galvanized Steel Flashing Material Finish Clear and black anodized aluminum Weight 0.16 Ibs Design Uplight Load 200 Ibs Uplift Design Ultimate Load 1,000 Ibs Uplift Warranty 10 Year material and worksmanship SnapNrack- PV MounVng Systems (877) 732-2860 www.SnapNrack.com () Printed on recycled paper using soy based inks. 2013 by SnapNrack PV Mounting System.All rights reserved. -PLAN KEY ®-�LmMETER ®-SERVICE DISCONNECT PROPOSED RESIDENTIAL PVi-0 COVER SHEET ®-SUPPLY SIDE CONNECTION FRONT OF HOUSE- FACING STREET OR DRIVEWAY A1-1 PARTIAL ROOF PLAN ®-AUTOMATICTRANSFER SWITCH PHOTOVOLTAIC SYSTEM A1-4 ROOF ACCESS PLAN e-GAS METER S1-1 STRUCTURE ®'MAIN SERVICE PANEL E1-1 ONE-LINE DIAGRAM ® SUB PANEL 171 RE IN SOLAR SYSTEMS INSTERDA ALLER 4355 E2-1 PV LABELS ®-wIRELESSflOUTER 171 REMINGTON BOULEVARD INSTALLER ACCESS RONKONKOMA,NEW YORK 11779 NUMBER ®-INVERTER ROOF G1-1 PV PHOTOS M.ENPHASE 1000MBINER Valenza Residence M-PANEL PHOTOVOLTAIC 710 WaterView Drive, Southold, NY 11971 Q-ELECTRIC VEHICLE CHARGER ®-ENPHASE ENVOY MS`P S - ®-SENSE CONSUMPTION MONITOR (E� = � Drawn By:J. DellaRocca-07/22/2024 ®-AC DISCONNECT /fin I� (1ST) - ©-TESLAGATEWAY DSI� �( REpq� ®-TESLA POWERWALL V �j� h♦ / �-ENPHASE IO SYSTEM CONTROLLER ACCESS ROOF `C q �st,_ o ®-ENPHASE 10 LOAD CONTROLLER "+1 ®•ENPHASE 1010 BATTERY �^ Z l/ ®-ENPHASE 10 3 BATTERY ♦��/� V/ ®-GENERATION PANEL ®- BACKEDUPLOADSCENTER -18"-VENTILATION 0-VENT PIPE -18"-VENTILATION O?9 m--EXTERIOR LOCATION OF _;0 nm-1 ST FLOOR LOCATION ACCESS Bull �W ROOF -- BASEMENTLOCATION < < Town building examiner has received the enclosed document for minimum acceptable --GARAGELOCATION 0 plan submittal requirements of the town as specified in the building and/or Residential VVV V V Code of the State of New York. This review does not guarantee compliance with that code. that responsibility is guaranteed under the seal and signature of the New York VVV State licensed design professional of record. That seal and signature has been PROPOSED PV SYSTEM interpreted as an attestation that,to the best of the licensee's belief and information the work in this document is: Module Type/Qty: (22)REC420AA Pure 2 18"-VENTILATION • Accurate Module Dimension: 73.411 x 40.9"x 1.211 18"-VENTILATION Conforms with governing codes applicable at the time of submission 717V Conforms with reasonable standards of practice and with view to the Module Weight/PSF: 47.6 Ibs/2.27969348659004 PSF licenseerding of life,health,property and public welfare is the responsibility of the Micro Inverter: (22)Enphase 108A-72-2-US EGRESS vvovvvvv ACCESS Structural Statement System DC Rating: 9,24 kW -3W- - The existing structure is adequate to support the new loads imposed by the System AC Rating: 7.656 kW/AC L photovoltaic module system including uplift and shear. The existing rafter sizes Aurora Estimated AC Production: 10,048 kWh r and dimensions conform to RC-NYS 2020 table R802.4.1(2)-Rafter Spans. N (3)PROPOSED PV MODULES PV Notes (19)PROPOSED PV MODULES 1. This PV system has been designed to meet all current and applicable fire prevention setback pathways per 2020 NYS Residential Code. Proper ground clearance,roof access points,access pathways and ventilation systems shall be provided where necessary. An in depth description of each applicable code reference and exception for any codes is depicted on the PV-1 plate of this drawing package. 2. Roof shall have no more than a single layer of roof covering in addition to the solar equipment. 3. Installation of solar equipment shall be flush-mounted,parallel to and no more than 6-inches above the surface of the roof. 4. Weight of the installed system shall not exceed more than 5-psf 5. Any plumbing vents are not to be cut or covered for solar equipment installation. Any relocation or modification of the vent requires a plumbing permit and FULL HOUSE ROOF PLAN inspection. SCALE:N.T.S. This PV system has been designed to meet the minimum design standard for building and other structures of the ASCE 7-16 and the 2020 New York State Residential Code. PV1 m COVER PAGE JOB# 24474 REVISION # N/A ci SUNATION REVISED BY N/A G S"ER Cn Z M 0 RIDGE ROOF AREA 0 36-5Y2" • W I 11-V RIDGE CAPPING PHOTOVOLTAIC MODULE (TYP.) SUNATION 10 • xq go : SuNation Solar Systems • • ROOF 1 171 Remington Blvd. All Ronkonkoma,New York 11779 RIDGE (631)-750-9454 19'-6y2. • 16�1" • NYSERDA INSTALLER NUMBER 4355 • 11111111r_7 WWI JOB NUMBER • \7 24474 0 L_oo .L.. .. A-. 110'. 3" 2'.6" 52'-7" GUTTER COIJ Z Z CIRCUIT 2- ROOF 2 RIDGE -CIRCUIT 1 0 '- C-1 d iz 3 - ? V-6" i7i 0 ID 0 as U. CZ .> Z N LL1 0 CU D > C0 co lZ-5y2" \7 X8 C� V* 9'-7)/2 GUTTER Roof# Roof Description Modules Azimuth Tilt Pitch Attachment Spacing: Portrait Attachment Spacing:Landscape 3/16"= 1'-0" Interior Edge Corner Interior Edge Comer 1 Southeast Roof 19 1360 450 12/12 4811 3211 1611 6411 4811 4811 A 1 =1 2 Southeast Roof 3 1360 210 5.6/12 4811 3211 1611 6411 64" 1 4811 PARTIAL ROOF PLAN SOLAR,ENERGY SYSTEMS (NY) R324.6 Roof access and pathways. Roof access, pathways and �C,�STERF� setback requirements shall be provided in accordance with Sections �CHA '9 R324.61 through R324.6.2.1. Access and minimum spacing shall be required to provide emergency access to the roof,to provide pathways to specific areas of the roof, provide for smoke ventilation opportunity Cn Z areas and to provide emergency egress from the roof. i a m Exceptions: �f 1. Detached, nonhabitable structures, including but not limited to 61 detached garages, parking shade structures, carports, solar FRONT OF HOUSE- FACING STREET OR DRIVEWAY FW YO?� trellises and similar structures, shall not be required to provide roof access. 2. Roof access, pathways and setbacks need to be provided where the building official has determined that rooftop operations will not be employed. 3. These requirements shall not apply to roofs with slopes of two `✓ SUNNTION units vertical in 12 units horizontal(17-percent slope)or less ACCESS ` ROOF [NY] R324.6.1 Pathways. Not fewer than two pathways, on separate SUNation Solar systems roof planes from lowest roof edge to ridge and not less than 36 inches 171 Remington Blvd. Ronkonkoma,New York 11779 (914 mm)wide, shall be provided on all buildings. Not fewer than one (631)-750-9454 pathway shall be provided on the street or driveway side of the roof. ��M1 -- SS For each roof plane with a photovoltaic array, a pathway not less than (EXT) Ul1l MSP I NYSERDA 36 inches (914 mm)wide shall be provided from the lowest roof edge (1ST) INSTALLER 4355 to the ridge on thee same roof plane as the photovoltaic array, on an AC IQ NUMBER adjacent roof plane, or straddling the same and adjacent roof planes. DSC == Pathways shall be over areas capable of supporting fire fighters ACCESS JOB NUMBER accessing the roof. Pathways shall be located in areas with minimal ROOF obstructions such as vent pipes, conduit, or mechanical equipment. /� �/� Pathways on opposing roof slopes shall not be located along the same 244 4 plane as the truss, rafter, or other such framing system that supports the pathway. Exception: 18"-VENTILATION 18"-VENTILATION 1. Access pathways shall not be required on roof slopes containing photovoltaic modules, panels, or an array where the opposing ACCESS or adjacent roof slope is an access roof. ROOF r N < < Z Z N Access Roof-A roof surface that: °VVV VV o 0 a � Y 1. Can be accessed from the ground by the fire service. N Vro 0 V�\/2. Is capable of providing fire service access to the ridge or peak p ¢ fr u_"-VENTILATION of an opposing or adjacent roof surface that contains 18 Z N .> 5 _ photovoltaic modules,panels,or an array. 18"-VENTILATION a 0 3. Is relatively free of vents,skylights,conduits,mechanical I H > equipment and other such obstructions. VVV a) m 4. Does not contain photovoltaic modules, panels or an array,or is EGRESSvvovvvvv i° a single ridge roof where the maximum edge to edge width of ACCESS the photovoltaic panel system does not exceed 33 percent of O n the ridge length. [NY] R324.6.2 - Setback at ridge. Photovoltaic arrays shall not be (3)PROPOSED PV MODULES located less than 18 inches(457 mm)from a horizontal ridge. [NY] R324.6.2.2 - Emergency escape and rescue opening. Panels (19)PROPOSED PV MODULES and modules installed on dwellings shall not be placed on the portion of the roof that is below and emergency escape and rescue opening. A pathway not less than 36 inches(914 mm)wide shall be provided to the emergency escape and rescue opening. 1/8" = V-0" A1 =4 ROOF ACCESS PLAN �,rSTER� Typical Attachment Method ��C �<-f- co �+ s �" nl RIDGE ' " SNAP'N'RACK ULTRA RAIL S PHOTOVOLTAIC 20-0.5 77 MODULE F►v YOR SNAP'N'RACKSPEEDSEAL L-FOOT 3/4"MODULE SPACING BETWEEN ROWS AND INSTALLERS TO APPLY SEALANT ON COLUMNS(TYP.) BOTTOM SEALANT RING ♦� SUNATION USE-NPC Solar Seal#900 (1)LAYER COMPOSITE \` SHINGLE SUNation Solar Systems RAIL (1)5/1B"x5"0 171 Remington Blvd. SEALING LAG SCREW / Ronkonkoma,New York 11779 FASTENED TO RAFTER / (631)-750-9454 / RAFTER / j// / INSTALLER 4355 2" X 6" / 16" O.C. / NUMBER PLYWOOD DECKING JOB NUMBER (TYP-) WOOD FRAMING 24474 (TYP.) SOFFIT ATTACHMENT TYPE APPLIED TO-ROOF'TYP" EXTERIOR WALL 12'-10" —I N ROOF SECTION (TYP.) r O SCALE: N.T.S. } N Z C14 N � Z U 75 O SOLAR MODULE FRAME O NOTE:3/4"SPACING BETWEEN MODULE ROWS Q co Roof# Rafter Size/Spacing Max Span Material Layers Sheathing AND COLUMNS. �0 0 CC 1 2"x 6"/16" O.C. 12'-10" Composite Shingles 1 Plywood (IYP)�MP OLL �+� co > — �� �� " " Composite Shingles Plywood 45• HEIGHT ADJUSTABLE W C Q N 2 2 x 6 /16 O.C. 11 -2 po g 1 Yw L-FOOT W 0 CZ N SNAP'WRACK ULTRA RAIL m (TYP•) C 5.$" HEIGHT OFF OFCZ i ROOF SURFACE O Q T ^f)LATRIM'ST-55PEST AND Typical Module DEBRIS BARRIER O CUTAWAY Side Profile FOR CLARITY. CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA - TABLE R301.2(1) WIND DESIGN SUBJECT TO DAMAGE ICE BARRIER SEISMIC DESIGN WINTER DESIGN MEAN ANNUAL UNDERLAYMENT FLOOD HAZARD AIR FREEZING INDEX GROUND SNOW SPEED(MPH.) TOPOGRAPHIC SPECIAL WIND ZONE WIND BORNE DEBRIS CATEGORY WEATHERING FROST LINE DEPTH TERMITE TEMPERATURE REQUIRED TEMPERATURE S 1 1 LOAD EFFECTS ZONE _ 20 PSF 140 B YES 2 B SEVERE 3'-0" MODERATE TO 15 DEG N/A SEE PLANS 599 51 HEAVY EXAMINER STRUCTURE a �G\ TERFD HAF4/r O ? co G —t z m a Enphase A/C Branch Circuit (typ.) AIL SERVI 0 817 N Y ORS N Enphase Microinverter(typ.) N N Exlatinng PSEG Utility Meter COMBINER Account#-9632929402 `✓ Meter#- Module J-Box(typ.) PANEL 1z�aov rl SUNATION SUPPLY SIDE CONNECTION `J SUNation Solar Systems PV Module(typ.) 171 Remington Blvd. Ronkonkoma,New York 11779 150A (631)-750-9454 EGC Attached To Rail(typ.) MAIN NYSERDA 4355 ENPHASE GATEWAY INSTALLER (No bads,rn-Ring mly) 5 NUMBER JOB NUMBER 2P15A CONDUIT AND CONDUCTOR SCHEDULE 24474 TAG CONDUCTOR CONDUIT RUN ENPHASE BRANCH CIRCUIT#1 2P20A \ Circuit#1 40A /) TYPE GAUGE QUANTITY TYPE SIZE LENGTH ENPHASE BRANCH CIRCUIT#2 �?P2ftOA MAIN u #2 1 Enphase Q-Cable 12 4 N/A N/A 15' EGC G G 3 THWN-2 10 4 PVC SCH.80 1.25" 15' 1 2 3 MAIN ENPHASE A/C SERVICE IQ COMBINER DISCONNECT PANEL EGC 10 1 PVC SCH.80 1.25" 15' ROOF ATTIC EXTERIOR SERVICE C\I 4 THWN-2 8 3 PVC SCH.80 1.25" 10' 4 ENCLOSURETED 6 O EGC 10 1 PVC SCH.80 1.25" 10' MIN.1O CV MIN.10k AIC Z N 5 THWN-2 6 3 PVC SCH.80 1.25" 10' N EXTERIOR 6 GEC 8 1 N/A N/A 10' DISCONNECTING MEANS BUILDING OZ 0 0 GROUNDING ELECTRODE O +�. C» C/) O 0 rr fr Z Cz 2! — Circuit# PV Module oty. Micro-Inverter Qty. Maximum AC Operating Current F 1 REC420AA Pure 2 11 Enphase IQ8A-72-2-US 11 15.95 A > 2 REC420AA Pure 2 11 Enphase IQ8A-72-2-US 11 15.95 A m co o T Maximum AC Operating Current(Total) 31.9 A E1 =1 ONE-LINE DIAGRAM �G1Se,LR LABEL LOCATION: LABEL LOCATION: _A�GH/j,< MAXIMUM AC OPERATING CURRENT SOURCE CIRCUITS: 1 AT EACH AC DISCONNECT,COMPLETE VOLTAGE AND Service Disconnect MAIN DISCONNECT PANEL: 1 AT EACH AND AT BUILDING MAIN SERVICE l CURRENT VALUES ON DISCONNECT LABEL. DISCONNECT IF APPLICABLE. co NOMINAL AC OPERATING CURRENT: G NEC 2017 690.54/NEC 2017 690.13(B) of NEC 2017 705.10 >Second Disconnect IQ Located next to Meter 1 WARNIj 2 . - EW YuR ELECTRIC SHOCK HAZARD • NOTE:ATTENTION STICKER GETS PLACED ON UTILITY METER IN ADDITION TO DO NOT TOUCH TERMINALS THE BUILDING MAIN SERVICE DISCONNECT. TERMINALS ON BOTH THE LINE AND Primary Service Disconnect LOAD SIDES MAY BE ENERGIZED This building is equipped with an +� IN THE OPEN POSITION • • - Interconnected Electric Power 1 SUN^TION PFKnUV LTAIC MOOULES PRODUCE DCVOLTAM Production Source J � �'9Y wHENEVMTWYNEEXPOWTosuKlcHT r • SUNation Solar Systems Source Type: 171 Remington Blvd. Solar Photovoltaic Ronkonkoma,New York11779 (631)-750-9454 Disconnect is Located. Interior. Basement: Garage: Exterior: NSS ARDER 43 5 5 Front: Rear: LH Side: NUMBER RH Side: Other Location: SUNation Solar Systems SOLAR SYSTEM EQUIPPED JOB NUMBER 631-750-9454 www.sunation.com WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN 24474 SWITCH TO THE PHOTOVOLTAIC SYSTE "OFP'POSITON TO nrgs _ SHUTDOWN PV SYSTEM EQUIPPED WITH WID AND REDUCE THE SHOCK HAZARD SHUTDOWN IN ARRAY LLI r N r O } CV Z CV N Z L) O O O r Q 0 U Cn O cr Q) rr Z Cz > W H O U) j > >+ � m CCz O ` AT 1_ E2= 1 PV LABELS } /^• ",; `.yam+ . F ri _ w 74 r_ + FW YOFt �, •.. 4 NTIO� ISUN N •_"„ -----_ :„ f' :' SUNation Solar Systems M, ® to }» 171 Remington Blvd. - Ronkonkoma,New York 11779 (631)-750-9454 NYSERDA • d s!y. i NUMBER 4355 INSTALLER t i���•,. JOB NUMBER .. .. . 24474 ARRAY LOCATION(S) ARRAY LOCATION(S) SATELLITE IMAGE VIA GROUND VIA DRONE T ..y V ? _ L Q) cri MENe o Z M ! — W cz ca 1 SOUTH VIEW PROPOSED PV EQUIPMENT EXISTING UTILITY METER VIA ROOF LOCATION AND MDP G I =1 PV PHOTOS