HomeMy WebLinkAbout51945-Z TOWN OF SOUTHOLD
BUILDING DEPARTMENT
TOWN CLERK'S OFFICE
SOUTHOLD, NY
BUILDING PERMIT
(THIS PERMIT MUST BE KEPT ON THE PREMISES
WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS
UNTIL FULL COMPLETION OF THE WORK AUTHORIZED)
Permit#: 51945 Date: 05/27/2025
Permission is hereby granted to:
Brian Schiele
37 Dogwood Ln
Rockville Centre, NY 11570
To:
Legalize "as built"additions and alterations to an existing single-family dwelling as applied for to
include an enclosed deck and finished basement.Additional certification may be required.
Premises Located at:
1510 Maple Ln, Greenport, NY 11944
SCTM#35.-6-4
Pursuant to application dated 04/17/2025 and approved by the Building Inspector,
To expire on 05/27/2027.
Contractors:
Required Inspections:
Fees:
As Built Addition/Alteration $1,570.00
CO Single Family Dwelling-Addition /Alteration $100.00
Total $1,670.00
n
fl
�� Building Inspector
TOWN OF SOUTHOLD—BUILDING DEPARTMENT
z' Town Hall Annex 54375 Main Road P. O.Box 1179 Southold,NY 11971-0959
vs� + � Telephone(631) 765-1802 Fax(631)765-9502 litto :// w�v.seutholdtowtuiy. ow
o ' u.
k
Date Received
APPLICATION FOR BUILDING PERMIT
4'11 LC EE VE
For Office Use On ��� � ��
PERMIT NO. S Building Inspector
7�.i.'1i
Applications and forms must be filled"out in their entirety.Incomplete
applications w„rll not be,accepted Where the APPlwant rs not tl+e owned an
E u's4dl cs ne alm, ent
Town of Southolid
OWner's Authorization form(Pap 2)shall be comp„le#ed."
Date:04/08/25
O�AINER(S)OF PROPERTY.
Name:Brian Schiele and Chloe Schiele scTM#1000-35,6-4
Project Address:1510 Maple Lane, Greenport, NY 11944
Phone#:516-456-1485 Email:bschiele@fhloans.com
Mailing Address:1510 Maple Lane, Greenport, NY 11944
CONTACT PERSON:
Name:Krista Jones
Mailing Address:PO Box 948, Cutchogue, NY
Phone#:631-335-8175 Email:millstonepropertyservices@gmail.com
DESIGN PROFESSIONAL INFORMATION
Name:John McNeill
Mailing Address:321 Riverside Drive, Riverhead, NY 11901
Phone#i516-376-8594 Email:john@mcneilla,rchitecture.com
CONTRACTOR INFORMATION:
Name:Stuart Daccus
Mailing Address:1549 Main Road, Riverhead NY
Phone#:631-276-3334 Email:amsremodelingcontractors@gmail.com
DESCRIPTION OF PROPOSED CONSTRUCTION
❑New Structure ❑Addition RAlteration ❑Repair ❑Demolition Estimated cost of Project:
❑Other $15,000
Will the lot be re-graded? ❑Yes BNo Will excess fill be removed from premises? ❑Yes BNo
1
PROPERTY INFORMATION
Existing use of property:residential intended use of property:residential
Zone or use district In which premises Is situated: Are there any covenants and restrictions with respect to
R_40 this property? OYes BNo IF YES,PROVIDE A COPY.
O"! eck Box After Reading: ew~/wMmtUWj pWftj Wm1 b mpmAle fw d Nod StWM WWW ISM"89 OMWOW bY.
2Mo1 d*"ro�M 0W*.MiP"KATION is,WMV WAX t0the bulmiq r the Ft a "am z0ft
waft'la""r"of old,W"kr tbt�'*W*0*sod ww"ga kable tows,wChrdlawwram or 0406*Mro A*the 0010 r*0"010411k pw,
ur, t W rtk"ar*mnovO aar d*NA 66h a IrwcMn Olt*"to tomplp o"to sppiwblr IwMwwaw,o flrewrawar Mom,
MoftcWe e "*m wW to admit w0weew to a pre lta mW In l► ) !,I&*� .r a wawdiw e
as tw cieww x v p x ewe t* 210A°S of I Me t!M W'V*1 c SWU M'wtMI tawwatw„
Application Submitted By(print name):Krista Jones BAuftrized Agent Downer
Signature of Applicant: Date:
STATE OF NEW YORK) CONNIE D.BUNCH New York
SS: Notary Public,SU'te Of
No.01BU6185050
COUNTY OF 1 Qualified in Suffolk county
commission EawPIres,Afarll
being duly sworn,deposes and says that(s)he is the applicant
(Name of individual signing contract)above named,
(S)he is the
(Contractor,Agent,Corporate Officer,etc.)
of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this
application;that all statements contained in this application are true to the best of his/her knowledge and belief;and
that the work will be performed in the manner set forth in the application file therewith.
Sworn before me this
4 "
y of 20
Notary Public
l'R PERTY OWNER AU'THORi' ATIO
(Where the applicant is not the owner)
1, ' �� rwesiding at 1510 Maple Lane
do hereby authorize Krista Jones to apply on
my behalf to o n of So Building Department for approval as described herein.
Owne Signature Date
Soh-
Print Owner's Name
2
'bp4 51qqs
co
CV
T
EXISTING
SKYLIGHT
12'-4" EXISTING 4x4 P.T.
POST TO FOOTING
I / BELOW (TYP.)
36" RAILING 1
A.1
36' RAILI
EXISTING
SKYLIGHT
ENCLOSED
DECK
DECK PLAN
SCALE: 1/4" = 1'-0"
REAR ELEVATION
SCALE: 1/4" = V-0"
CONSTRUCTION NOTES:
FOR COMPRESSIVE STRENGTH OF
CONCRETE SEE TABLE R402.2 ON
DWG A.5
ANY / ALL LUMBER THAT COMES
INTO CONTACT WITH CONCRETE
SHALL BE ACQ
ALL CORNERS OF THE FRAMING
TO BE CONTINUOUS STRAP DOWN
WITHIN A MIN. OF 10% OF THE LEAST
HORIZONTAL DIMENSION
COLLAR TIES TO LOCATED IN THE
UPPER 1/3 RD OF THE ATTIC
BATH WINDOW TO CONFORM
TO THE HAZARDOUS GLAZING
REQUIREMENTS AS PER SECTION 308.4
OF THE NEW YORK STATE RES. CODE.
TEMPERED GLASS REQUIRED AT
GLASS OPENINGS WITHIN 18" AFF
BLOCK UNDERSIDE OF NON -BEARING
INTERIOR WALLS RUNNING PARALLEL
W/ FLOOR JOIST.
5'-6"
c)
(V
2x8 R.R.
@16" O.C.
�—
EXISTING W
(.o
SKYLIGHT O
Q.'
0
x
N
M
N
i
2x8 R.R.
@16" O.C.
EXISTING
SKYLIGHT
DECK ROOF PLAN
SCALE: 1/4" = 1'-0"
RIGHT SIDE ELEVATION
SCALE: 1/4" = 1'-0"
LEGEND
NEW FOUNDATION
SEE DETAILS
NEW INTERIOR
WALL & PARTITION
NEW EXTERIOR
WALL
NEW WINDOW
O
O
NEW DOOR
SD
HARDWIRE SMOKE
DETECTOR
C co
CARBON MONOXIDE
DETECTOR
O E F
EXHAUST FAN TO
EXTERIOR PER R303.3
LEFT SIDE ELEVATION
SCALE: 1/4" = 1'-0"
Nu RIDGE
Nu 1 T 3T 3-1 /2"
T.O. PLATE
� 13'-3"
q FIRST FL001
q_J4'-9"
—GRADE
(0 -0 )
SECTION 1-1
SCALE: 1/4" = 1'-0"
EXISTING 2x10 RIDGE
EXISTING ASPHALT
ROOF SHINGLES
EXISTING GUTTER
AND FASCIA
EXISTING (2) 2x8 BEAM
WRAPPED IN PVC TRIM
EXISTING 44 POST
WRAPPED IN PVC TRIM
EXISTING SCREEN
PANELS
EXISTING 36"
RAILING
EXISTING COMPOSITE
DECKING OVER 2x8 PRESSURE
TREATED DECK JOIST @ 16"o.c.
EXISTING CONCRETE
FOOTING
321 RIVERSIDE DR
RIVERHEAD, NY 11901
(516 )376-8594
Client Info
BRIAN & CHLOE SCHIELE
LINE OF 1510 Maple Lane
DECK ABOVE EXISTING 44 P.T. East Marion, NY
POST ON CONCRETE
�FOOTING (TYP.)
Project Info
I (2) 2x12 P.T. BEAM ' LEGALIZE EXISTING FINISHED
I Q I BASEMENT & ROOF OVER EXISTING
I W I DECK
I I I 1510 Maple Lane
I
W o b a I East Marion, NY
co
\4- O 0 I
IF7 = x
I a- d Cfl N
N
I N co EXISTING
DUCTLESS a
a
HVAC SYSTEM a
2x8 P.T. LEDGER
3068
UP
EXIST OIL JEC w
TANK UMP E' BATH tZ zo a U
•c O
?6,� `L� j tUn z
[il N O
O 0 v
LL O
AIR
N N HAND. Z
o
o �6'8 U
r-
LO
� N
w w EXIST. RECREATION SPACE _ _ _ -o- _ _ v o
o v o Ix
o CEILING HEIGHT - 7' 10-1/2" _ _ EXISTING BEAM (6' 10-1/2"
z `r Z v CLEAR HEIGHT UNDERNEATH)
� X J w �' Cv UNEXCAVATED
W� o w m N EXISTING GARAGE
�CNUo ABOVE
w z 2x10 F.J.
@16" O.C.D'
w z X FURN. - - - -o- - - - - V�I Ally '
C„ o z
W CK CLEAR HEIGHT UNDERNEATH) N
QOO�... `
�� N
Wp� 11-5
rn
In
EXIST. RECREATION SPACE
�4 LAUNDRY 0)� Oso CEILING HEIGHT - T 10-1/2" fi �
�8 aM
Cl)CD
O
x Z 9'-0" D 15� 16'-11 1/2"
11
SECTION AND
DETAILS
EXISTING BASEMENT PLAN
SCALE: 1/4" = 1'-0"
Drawn By
J.E.M.
Drawing No.
Checked By
J.E.M.
A-1
Sheet 1 of 3
TABLE 3.1 (NAILING SCHEDULE)
JOINT DESCRIPTION
# OF NAILS
NAIL SPACING
ROOF FRAMING
Rafter to Top Plate (Toe -nailed)
(see Table 3.3A)
per rafter
Ceiling Joist to Top Plate (Toe -nailed)
(see Table 3.3A)
per joist
Ceiling Joist to Parallel Rafter (Face -nailed)
(see Table 3.7)
each lap
Ceiling Joist Laps over Partitions (Face -nailed)
(see Table 3.7)
each lap
Collar Tie to Rafter (Face -nailed)
(see Table 3.4)
per tie
Blocking to Rafter (Toe -nailed)
2- 8d
each end
Rim Board to Rafter (End -nailed)
2- 16d
each end
WALL FRAMING
Top plate to Top Plate (Face -nailed)
2- 16d
per foot
Top Plate at Intersections (Face -nailed)
4- 16d
joints - each side
Stud to Stud (Face -nailed)
2- 16d
24" o.c.
Header to Header (Face -nailed)
16d
16" o.c. along edges
Top or Bottom Plate to Stud (End -nailed)
2- 16d
per 2 x 4 stud
3- 16d
per 2 x 6 stud
4- 16d
per 2 x 8 stud
Bottom Plate to Floor Joist, Band Joist,
2- 16d
per foot
End Joist or blocking (Face -nailed)
FLOOR FRAMING
Joist to Sill, Top Plate or Girder (Toe -nailed)
4- 8d
per joist
Bridging to Joist (Toe -nailed)
2- 8d
each end
Blocking to Joist (Toe -nailed)
2- 8d
each end
Blocking to Sill or Top Plate (Toe -nailed)
3- 16d
each block
Ledger Strip to Beam (Face -nailed)
3- 16d
each joist
Joist on Ledger to Beam (Toe -nailed)
3- 8d
per joist
Band Joist to Joist (End -nailed)
3- 16d
per joist
Band Joist to Sill or Top Plate (Toe -nailed)
2- 16d
per foot
ROOF SHEATHING
Structural Panels
8d
12" o.c.
Diagonal Board Sheathing
1'W" or 1"x8"
2- 8d
per support
1 "x10 or wider
3- 8d
per support
CEILING SHEATHING
Gypsum Wallboard
5d coolers
7" edge/10" field
WALL SHEATHING
Structural Panels
8d
12" o.c.
Fiberboard Panels
7/16"
6d
3" edge/6" field
25/32"
8d
3" edge/6" field
Gypsum Wallboard
5d coolers
7" edge/10" field
Hardboard
8d
12" o.c.
Particleboard Panels
8d
12" o.c.
Diagnonal Board Sheathing
1 "x6" or 1 "x8"
2-8d
per support
1 "x10" or wider
3-8d
per support
FLOOR SHEATHING
Structural Panels
1" or less
8d
6" edge/12" field
greater than 1"
10d
6" edge/6" field
Diagnonal Board Sheathing
1 "x6" or 1 "x8"
2-8d
per support
1 "x10" or wider
3-8d
per support
MINIMUM UNIFORM DISTRIBUTED DESIGN LOADS
( REFER TO TABLE R301.5 OF THE RESIDENTIAL CODE OF NEW YORK STATE)
USE
LIVE LOAD
DEAD LOAD
EXTERIOR BALCONIES
60 PSF
10 PSF
DECKS
40 PSF
10 PSF
PASSENGER VEHICLE GARAGES
50 A PSF
AS PER PLAN
ATTICS WITHOUT STORAGE (ROOF BELOW 3 PITCH)
10 PSF
10 PSF
ATTICS WITH STORAGE (ROOF BELOW 3 PITCH)
20 PSF
10 PSF
ROOMS OTHER THAN SLEEPING ROOMS
40 PSF
10 PSF
SLEEPING ROOMS
30 PSF
10 PSF
STAIRS
40 PSF
10 PSF
GUARDRAILS AND HANDRAILS
200 PSF
10 PSF
ROOF LOADING LIVE -GROUND SNOW LOAD
30 PSF
10 PSF
TABLE R301.5
MIN. ROOF LIVE LOADS IN
POUNDS -FORCE PER S.F. OF
HORIZONTAL PROJECTION
TRIBUTARY LOADED AREA IN S.F.
FOR ANY STRUCTURAL MEMBER
ROOF SLOPE
0 TO 200
201 TO 600
OVER 600
FLAT OR RISE LESS
20
16
12
THAN 4 IN. PER FT. (1:3)
RISE 4 IN. PER FT. (1:3) TO
16
14
12
LESS THAN 12 IN. PER FT. (1:1)
RISE 12 IN. PER FT.
12
12
12
(1:1) AND GREATER
R905.2.5 - FASTENERS
FASTENERS FOR ASPHALT SHINGLES SHALL BE GALVANIZED STEEL, STAINLESS
STEEL, ALUMINUM OR COPPER ROOFING NAILS MIN 12 GAGE SHANK WITH A MIN
3/8" HEAD ASTMF1667 OF A LENGTH TO PENETRATE THROUGH THE ROOFING
AND A MIN OF MATERIALS 3/4" INTO THE ROOF SHEATHING WHERE THE ROOF
SHEATHING IS LESS THAN 3/4" THINK THE FASTENERS SHALL PENETRATE
THROUGH THE SHEATHING R905.2.6 - ASPHALT ROOF SHINGLES SHALL HAVE A
MINIMUM OF SIX FASTENERS 3/8" PER SHINGLE WHERE THE ROOF SLOPE IS IN
ONE OF THE FOLLOWING CATEGORIES: THE BASIC WIND SPEED IS 110 MPH OR
GREATER AND THE EAVE IS MORE THAN 20' ABOVE GRADE.
GROUND SNOW LOAD - 20 PSF
AS PER FIGURE 301.2(5) GROUND SNOW LOAD FOR NYS
WIND SPEED -130 MPH
AS PER FIGURE 301.2(6) BASIC WIND SPEEDS FOR 50 YEAR
MEAN RECURRENCE INTERVAL
AS PER FIGURE R301.2.11 DESIGN CRITERIA - WHERE WIND
SPEED IS 130 MPH OR ABOVE SHALL BE DESIGNED IN
ACCORDANCE WITH THE AF &PA WOODFRAME CONSTRUCTION
MANUAL FOR ONE AND TWO FAMILY DWELLINGS - WFCM
SEISMIC DESIGN CATEGORY - C
AS PER FIGURE R301.2(2) INTERNATIONAL RES. CODE SEISMIC
DESIGN CATAGORY
SUBJECT TO DAMAGE FROM WEATHERING SEVERE
AS PER FIGURE R301.2(3) WEATHERING PROBABILITY MAP FOR
CONC.
FROST LINE DEPTH - 3'
AS PER R403.1(1) CONCRETE AND MASONRY DETAILS
TERMITE - MODERATE TO HEAVY
AS PER R301.2(6) TERMITE INFESTATION MAP
DECAY - SLIGHT TO MODERATE
AS PER R3012(7) DECAY PROBABILITY MAP
WINTER DESIGN TEMP. - SUFFOLK CTY II - NASSAU COUNTY 13
AS PER N1101.2 CLIMATIC CONDITIONS FOR NYS
ICE SHIELD AND UNDERLAYMENT REQUIRED - YES
AS PER N SEC 905.7.1- IN AREAS WHERE THE AVERAGE TEMP. IN
JANUARY IS 25 DEGREES F (4 DEGREES C) OR LESS OR WHEN TABLE
R301.2(1) CRITERIA SO DESIGNATES. AS ICE BARRIER THAT CONSISTS
OF UNDERLAYMENT CEMENTED TOGETHER OR A SELF ADHERING
POLYMER MODIFIED BITUMEN SHEET SHALL BE USED IN LIEU OF
NORMAL UNDERLAYMENT AND EXTEND FROM THE EAVES EDGE
POINT AT LEAST 24" INSIDE THE EXTERIOR WALL LINE OF BUILDING.
*CODE COMPLIANCE NOTE*
THIS PROJECT COMPLIES WITH THE 2020 RESIDENTIAL CODE OF N.Y.S.
THE MECHANICAL CODE OF N.Y.S., CHAPTERS 12 THROUGH 24, THE
PLUMBING CODE OF NY STATE, CHAPTERS 25 THROUGH 32, AND THE
ELECTRICAL CODE OF NY STATE, CHAPTERS 33 THROUGH 42.
A. COMMON OR BOX NAILS ARE PERMITTED TO BE USED EXCEPT WHERE OTHERWISE
STATED.
B. NAILS SPACED AT 6" OC AT EDGES, 12" AT INTERMEDIATE SUPPORTS EXCEPT 6" AT
SUPPORTS WHERE SPANS ARE 48" OR MORE. FOR NAILING OF WOOD STRUCTURAL
PANEL & PARTICLE BOARD DIAGRAMS AND SHEAR WALLS, REFER TO SECTION 2305.
NAILS FOR WALL SHEATHING ARE PERMITTED TO BE COMMON, BOX OR CASING.
C. COMMON OR DEFORMED SHANK.
D. COMMON.
E. DEFORMED SHANK.
F. CORROSION RESISTANT SIDING OR CASING NAILS.
G. FASTENERS SPACED 3" OC AT EXTERIOR EDGES & 6" OC AT INTERMEDIATE SUPPORT.
H. CORROSION RESISTANT ROOFING NAILS WITH 7116" DIA HEAD AND 1 1/2" LENGTH FOR
1/2" SHEATHING AND 1 3/4" LENGTH FOR 25/32" SHEATHING.
I. CORROSION RESISTANT STAPLES WITH NOMINAL 7/16" CROWN AND 1 1/8" LENGTH FOR
1/2" SHEATHING AND 1 1/2" LENGTH FOR 25132" SHEATHING. PANEL SUPPORTS AT IT (20"
OF STRENGTH AXIS IN THE LONG DIRECTION OF THE PANEL UNLESS OTHERWISE MARKED)
J. CASING OR FINISH NAILS SPACED 6" ON PANEL EDGES, 12" AT INTERMEDIATE SUPPORT.
K. PANEL SUPPORTS AT 24". CASING OR FINISH NAILS SPACED T ON PANEL EDGES,12"AT
INTERMEDIATE SUPPORTS.
I. FOR ROOF SHEATHING APPLICATIONS, 8D NAILS ARE THE MIN. REQ'D FOR WOOD
STRUCTURAL PANELS.
M. STAPLES SHALL HAVE MIN. CROWN WIDTH OF 7/16".
N. FOR ROOF SHEATHING APPLICATIONS, FASTENERS SPACED 4" OC AT EDGES, 8" AT
INTERMEDIATE SUPPORTS.
0. FASTENERS SPACED 4" O.C. AT EDGES, 8" O.C. AT INTERMEDIATE SUPPORTS FOR
SUBFLOOR & WALL SHEATHING AND 3" OC AT EDGES, 6" AT INTERMEDIATE SUPPORTS
FOR ROOF SHEATHING.
P. FASTENERS SPACED 4" OC AT EDGES, 8" AT INTERMEDIATE.
R905.25 FASTENERS
FASTENERS FOR ASPHALT SHINGLES SHALL BE GALVANIZED STEEL, STAINLESS STEEL,
ALUMINUM OR COPPER ROOFING NAILS, MIN. 12 GAGE SHANK W/ A MIN. 3/8" HEAD ASTMF
1667, OF A LENGTH TO PENETRATE THROUGH THE ROOFING MATERIALS & A MIN. OF 3/4"
INTO THE ROOF SHEATHING. WHERE THE ROOF SHEATHING IS LESS THAN 314" THICK.
THE FASTENERS SHALL PENETRATE THROUGH THE SHEATHING R905.26 ASPHALT ROOF
SHINGLS SHALL HAVEA MIN. OF SIX FASTENERS PER SHINGLE WHERE THE ROOF IS IN
ONE OF FOLLOWING CATEGORIES - THE BASIC WIND SPEED PER R301.2(4) IS 110 MPH OR
GREATER & THE EAVE IS 20' ABOVE GRADE R905.27 FOR ROOF SLOPES FROM 2 VERTICAL
UNITS IN 12 UNITS HORIZONTAL UP TO 4 UNITS VERTICAL IN 12 UNITS HORIZONTAL UNITS
SHALL BE TWO LAYERS.
TABLE R402.2
MINIMUM SPECIFIED
COMPRESSIVE
STENGTH OF CONCRETE
MINIMUM SPECIFIED
TYPE OR LOCATION OF
COMPRESSIVE STRENGTH
a(fc )
WEATHERING POTENTIAL
CONCRETE CONSTRUCTION
NEGLIGIBLE
MODERATE
SEVERE
BASEMENT WALLS, FOUNDATIONS AND OTHER
2,500
2,500
2,500
CONCRETE NOT EXPOSED TO THE WEATHER
BASEMENT SLABS AND INTERIOR SLABS ON
2,500
2,500
2,500
GRADE, EXCEPT GARAGE FLOOR SLABS.
BASEMENT WALLS, FOUNDATION WALLS, EXTERIOR
VERTICAL CONC. WORK EXPOSED
2,500
3,000d
3,000d
WALLS & OTHER
TO THE WEATHER.
PORCHES, CARPORT SLABS AND STEPS EXPOSED
2,500
3,0000
3,000d,e
TO THE WEATHER, AND GARAGE FLOOR SLABS.
TABLE R 301.2(1)
CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA
GROUND
WIND
SEIMIC
SUBJECT TO DAMAGE FROM 1,2
WINTER
ICE SHIELD
FLOOD
SNOW
SPEED
DESIGN
WEATHERING FROST TERMITE DECAY
DESIGN
UNDERLAYMENT
HAZARDS
LOAD
(MFH)
CATEGORY
LINE DEPTH
TEMP
REQUIRED
20 PSF
1 130
C
I SEVER 3' M - H S - M
110
YES
o°
°
o
°
°
0o
0
°
°
°
O O
RIDGE
STRUCTURAL RIDGE
SIMPSON STRONG TIE WITH
SIMPSON STRONG TIE
CEIL. COLLAR TIES @32" O.C.
CATHEDRAL CEILINGS
CS-20X18" MIN. WITH (7)1 OD
(R-R)
COMMON NAILS PER RAFTER
INSTALLED OVER PLYWOOD
ri
FACE MOUNT HANGER
HIP RAFTER
SIMPSON STRONG TIE (LUS)
SIMPSON STRONG TIE
LUS26, LUS28, LUS26-2
#LS70
LUS 28-2, LUS210-2
HD38
MTS12HCP2
CONTINUOUS CORNER
HIP CORNER PLATE
POST STRAPPING
POST BASE
SIMPSON STRONG TIE (HCP)
SIMPSON STRONG TIE
SIMPSON STRONG TIE
HCP2 - 2" X MEMBER SIZE
VERTICAL HD38
# ABA44
HCP4 - 4" X MEMBER SIZE
SHINGLE
RIDGE CAP
SHINGLES
FELT
PAPER
�- RIDGE VENT
EXHAUST AIR
1/2" TO 3/4"
PLYWOOD
SHEATHING
RIDGE VENT
GALV. MTL. TIES @ EACH
STUD (TYP. OF ALL)
FLOOR JOISTS
TOP PLATES
GALV. MTL. TIES
@ BLOCKINGMETALSTR DETAIL
TRUSS AND RAFTER
CONNECTIONS TO
WOOD TOP PLATE
4
C V1 --1 E
321 RIVERSIDE DR
RIVERHEAD, NY 11901
(516 )376-8594
Client Info
BRIAN & CHLOE SCHIELE
1510 Maple Lane
East Marion, NY
Project Info
LEGALIZE EXISTING FINISHED
BASEMENT & ROOF OVER EXISTING
DECK
1510 Maple Lane
East Marion, NY
CO
z
w
0
O
0
z
O
i--
U
z
O
0
LO
N
0
N
0
DETAILS
Drawn By
J.E.M.
Drawing No.
Checked By
J.E.M.
A-2
Sheet 2 of 3
GENERAL NOTES
DIVISION 1
GENERAL NOTES:
THE CONTRACTOR SHALL VISIT THE SITE AND VERIFY
ALL CONDITIONS. ANY DISCREPANCIES, VOIDS OR
PROBLEMS SHALL BE REPORTED TO THE ARCHITECT
BEFORE SUBMISSION OF BID. A SUBMISSION OF BID
SHALL IMPLY CONTRACTOR ACCEPTANCE OF THE
DRAWINGS AND ALL EXISTING CONDITIONS.
DURING THE COURSE OF CONSTRUCTION IF
MODIFICATIONS TO THE DESIGN OCCUR AS A RESULT
OF EXISTING CONDITIONS, REQUEST OF CLIENT,
ARCHITECT, ETC. THE CONTRACTOR SHALL SUBMIT
TWO WRITTEN COPIES OF A CHANGE ORDER WITH
THE AMENDED PRICE. THE CONTRACTOR SHALL NOT
CONTINUE WITH ANY CHANGES UNTIL HE RECEIVES
WRITTEN AUTHORIZATION FROM OWNER OR
ARCHITECT.
IF IN THE COURSE OF CONSTRUCTION, A CONDITION
EXISTS WHICH DIFFERS FROM THAT AS INDICATED ON
THESE PLANS, THE CONTRACTOR SHALL STOP ALL
RELATED WORK AND NOTIFY THE ARCHITECT.
SHOULD HE FAIL TO FOLLOW THESE PROCEDURES
AND CONTINUE WITH THE WORK, HE SHALL ASSUME
ALL RESPONSIBILITY AND LIABILITY ARISING THERE
FROM.
THE AIA DOCUMENT A-201 (LATEST EDITION)
"GENERAL CONSTRUCTIONS, OR THE CONTRACTFOR
CONSTRUCTION" SHALL PREVAIL WHENEVER
POSSIBLE.
ALL WORK SHALL CONFORM TO THE 2010 NEW YORK
STATE RESIDENTIAL BUILDING CONSTRUCTION CODE
(LATEST EDITION) AND ALL RULES AND
REGULATIONS THEREIN AND WITH ALL OTHER
AGENCIES HAVING JURISDICTION.
THE CONTRACTOR SHALL MAKE SURE THAT ALL
TRADE'S WORK CONFORMS TO FEDERAL, STATE AND
MUNICIPAL CODES (BOCA) AND ORDINANCES. THESE
SHALL SUPERSEDE DRAWINGS, NOTES AND
DIMENSIONS INS ALL CASES. THE ARCHITECT SHALL
BE NOTIFIED OF SUCH CHANGES BEFORE WORK IS
STARTED. NON -FAMILIARITY WITH GOVERNING
RULES AND REGULATIONS WILL NOT BE CAUSE FOR
AN "EXTRA" BILLING. IN THE EVENT THAT WORK HAS
TO BE REPLACED FOR NON-COMPLIANCE, THE
CONTRACTOR SHALL BE HELD RESPONSIBLE IF HE
HAS NOT NOTIFIED THE ARCHITECT BEFORE INITIAL
INSTALLATION.
THE CONTRACTOR SHALL MAKE ANY CORRECTIONS
REQUIRED BY THE ARCHITECT. APPROVAL OF
DRAWINGS OR SCHEDULES SHALL NOT RELIEVE THE
CONTRACTOR FROM RESPONSIBILITY FOR
DEVIATIONS FROM DRAWINGS AND SPECIFICATIONS,
UNLESS HE HAS CALLED ATTENTION TO SUCH
DEVIATIONS (IN WRITING) AT THE TIME OF
SUBMISSION OF BID AND SECURED WRITTEN
APPROVAL. NOR SHALL IT RELIEVE HIM FROM
RESPONSIBILITY FOR ERRORS IN SHOP DRAWINGS OR
SCHEDULES OR THE PROPER PERFORMANCE OF
MECHANICAL EQUIPMENT AND CONTROLS.
THE WORD "PROVIDE" SHALL MEAN TO FURNISH AND
INSTALL ALL MATERIALS NECESSARY TO COMPLETE
THE WORK IN ACCORDANCE WITH ACCEPTED
CONSTRUCTION STANDARDS AND MANUFACTURER'S
RECOMMENDATIONS.
ALL ITEMS SPECIFIED ARE TO ESTABLISH QUALITY OF
WORK; PRODUCTS OF OTHER MANUFACTURER'S
EQUAL IN DESIGN, COLOR AND QUALITY MAY BE
SUBSTITUTED IF APPROVED BY THE ARCHITECT AS
MEETING ESTABLISHED DESIGN AND FUNCTIONAL
CRITERIA.
ALL WORK SHALL BE EXECUTED IN ACCORDANCE
WITH THE BEST -ACCEPTED TRADE PRACTICES AND AS
PER MANUFACTURER'S RECOMMENDATIONS.
CONTRACTOR IS TO INDICATE TO THE ARCHITECT
THE PROPOSED DATES AND HOURS DURING WHICH
WORK SHALL BE PERFORMED. THE CONTRACTOR
SHALL PREPARE AND UPDATE MONTHLY
CONSTRUCTION SCHEDULES; COMPLETION DATE MAY
NOT BE EXTENDED WITHOUT WRITTEN NOTICE.
CONTRACTOR SHALL OBTAIN ALL REQUIRED
BUILDING PERMITS, APPROVALS, UNDERWRITERS
CERTIFICATE, "C OF 0," AND/OR COMPLETION FOR
ALL WORK INDICATED FOR AGENCIES HAVING
JURISDICTION.
CONTRACTOR IS TO SUPPLY OWNER, IN WRITING, A
WAIVER OF ALL LIENS FOR HIMSELF AND ALL
SUPPLIERS AND SUBCONTRACTORS, AT THE TIME OF
EACH PAYMENT REQUEST.
DO NOT SCALE DRAWINGS, WRITTEN DIMENSIONS
SUPERCEDE SCALED DIMENSIONS.
BOOM CLEAN AFFECTED AREAS AND CARTS AWAY
ALL DEBRIS.
CONTRACTOR SHALL FURNISH AND INSTALL ALL
MATERIAL AND EQUIPMENT AS SHOWN, AND UNLESS
OTHERWISE NOTE, ALL EQUIPMENT SHALL BE NEW
AND OF BEST QUALITY.
DIVISION 2
SITE WORK:
LANDSCAPING: ALL TREES AND SHRUBS WHICH
INTERFERE WITH THE CONSTRUCTION OF THIS
PROJECT SHALL BE REMOVED; AND NEW
ORNAMENTAL TREES AND SHRUBS PLANTED, NEW
LAWN AREAS SHALL BE SEEDED AFTER FINISHED
GRADING IS COMPLETE.
STORM DRAINAGE: CONTRACTOR WILL VERIFY
REQUIREMENTS OF LOCAL AUTHORITIES FRO STORM
DRAINAGE.
SOILS:
EXCAVATE FOR ALL FOOTINGS, FOUNDATION WALLS,
AND OTHER SUCH WORK AS MAY BE NECESSARY TO
THE DEPTHS AS SHOWN ON THE DRAWINGS. ALL
TRENCHES FOR FOOTINGS, FOUNDATIONS, SLABS,
ETC. SHALL HAVE LEVEL, SOLID AND UNDISTURBED
BOTTOMS.
ALL SOIL BEARING CAPACITY ASSUMED AT 2 TONS /
SQUARE FOOT, CONTRACTOR SHALL VERIFY IN FIELD.
FILL USED OR ENCOUNTERED UNDERNEATH
FOUNDATIONS AND SLABS SHALL BE COMPACTED TO
A MINIMUM OF 96% MAXIMUM DENSITY IN
ACCORDANCE WITH THE MODIFIED PROCTOR TEST.
MAINTAIN 1:5:1 HORIZONTAL TO VERTICAL SLOPE
FOR ANY EXCAVATION ADJACENT TO FOOTINGS.
WHERE WALLS ARE POURED TO GRADE, THE
CONTRACTOR SHALL BACKFILL AGAINST THEM WITH
CLEAN EARTH. CARE SHALL BE TAKEN TO BRACE
THE WORK ADEQUATELY TO PREVENT DEFORMATION
OR COLLAPSE.
ALL MATERIALS USED FOR BACKFILL SHALL BE FREE
OF DEBRIS AND ORGANIC MATERIAL LARGER THAN 2
INCHES IN DIAMETER, LENGTH OR WIDTH.
WATER SHALL NOT BE ALLOWED TO STAND IN
EXCAVATIONS UNTIL AFTER CONCRETE WORK HAS
SET. CONTRACTOR SHALL REMOVE SUCH WATER AT
HIS WON EXPENSE.
TEMPORARY SHEET PILING, SHORING OR BRACING
SHALL BE PROVIDED AS REQUIRED TO MAINTAIN
EXCAVATION BANKS IN A SAFE AND STABLE
CONDITION.
NO BLASTING SHALL BE PERMITTED.
CONTRACTOR SHALL RETAIN A LICENSED CIVIL
ENGINEER TO PERFORM ALL DESIGN AND
SUPERVISION RELATED TO EXCAVATION,
UNDERGROUND UTILITY SERVICES,
(SUBSTANDARD -LESS THAN 2-TON/SQ.FT.) SOILS
ENCOUNTERED, ROADS, AND SITE STRUCTURES NOT
USUALLY CONSIDERED ARCHITECTURAL IN NATURE.
ALL BASEMENT WALLS BELOW GRAD SHALL BE
DAMP -PROOFED WITH TWO COATS OF ASPHALTIC,
SELF -PRIMING PLASTIC CEMENT, TROWEL OR SPRAY
APPLIED TO WALLS IF WATER TABLE IS DETERMINED
TO BE MINIMUM 2 FEET BELOW BASEMENT SLAB
ELEVATION. BENTONITE OR 60 ML LIQUID
WATERPROOF MEMBRANE AS MFR. BY ANTI -HYDRO
OR EQUAL SHALL BE USED IF WATER TABLE IS
HIGHER. CONTRACTOR SHALL VERIFY WATER TABLE
IN THE FIELD.
DIVISION 2
SITE WORK:
LANDSCAPING: ALL TREES AND SHRUBS WHICH
INTERFERE WITH THE CONSTRUCTION OF THIS
PROJECT SHALL BE REMOVED; AND NEW
ORNAMENTAL TREES AND SHRUBS PLANTED, NEW
LAWN AREAS SHALL BE SEEDED AFTER FINISHED
GRADING IS COMPLETE.
STORM DRAINAGE: CONTRACTOR WILL VERIFY
REQUIREMENTS OF LOCAL AUTHORITIES FRO STORM
DRAINAGE.
EXCAVATE FOR ALL FOOTINGS, FOUNDATION WALLS,
AND OTHER SUCH WORK AS MAY BE NECESSARY TO
THE DEPTHS AS SHOWN ON THE DRAWINGS. ALL
TRENCHES FOR FOOTINGS, FOUNDATIONS, SLABS,
ETC. SHALL HAVE LEVEL, SOLID AND UNDISTURBED
BOTTOMS.
ALL SOIL BEARING CAPACITY ASSUMED AT 2 TONS /
SQUARE FOOT, CONTRACTOR SHALL VERIFY IN FIELD.
FILL USED OR ENCOUNTERED UNDERNEATH
FOUNDATIONS AND SLABS SHALL BE COMPACTED TO
A MINIMUM OF 96% MAXIMUM DENSITY IN
ACCORDANCE WITH THE MODIFIED PROCTOR TEST.
MAINTAIN 1:5:1 HORIZONTAL TO VERTICAL SLOPE
FOR ANY EXCAVATION ADJACENT TO FOOTINGS.
WHERE WALLS ARE POURED TO GRADE, THE
CONTRACTOR SHALL BACKFILL AGAINST THEM WITH
CLEAN EARTH. CARE SHALL BE TAKEN TO BRACE
THE WORK ADEQUATELY TO PREVENT DEFORMATION
OR COLLAPSE.
ALL MATERIALS USED FOR BACKFILL SHALL BE FREE
OF DEBRIS AND ORGANIC MATERIAL LARGER THAN 2
INCHES IN DIAMETER, LENGTH OR WIDTH.
WATER SHALL NOT BE ALLOWED TO STAND IN
EXCAVATIONS UNTIL AFTER CONCRETE WORK HAS
SET. CONTRACTOR SHALL REMOVE SUCH WATER AT
HIS WON EXPENSE.
TEMPORARY SHEET PILING, SHORING OR BRACING
SHALL BE PROVIDED AS REQUIRED TO MAINTAIN
EXCAVATION BANKS IN A SAFE AND STABLE
CONDITION.
NO BLASTING SHALL BE PERMITTED.
CONTRACTOR SHALL RETAIN A LICENSED CIVIL
ENGINEER TO PERFORM ALL DESIGN AND
SUPERVISION RELATED TO EXCAVATION,
UNDERGROUND UTILITY SERVICES,
(SUBSTANDARD -LESS THAN 2-TON/SQ.FT.) SOILS
ENCOUNTERED, ROADS, AND SITE STRUCTURES NOT
USUALLY CONSIDERED ARCHITECTURAL IN NATURE.
ALL BASEMENT WALLS BELOW GRAD SHALL BE
DAMP -PROOFED WITH TWO COATS OF ASPHALTIC,
SELF -PRIMING PLASTIC CEMENT, TROWEL OR SPRAY
APPLIED TO WALLS IF WATER TABLE IS DETERMINED
TO BE MINIMUM 2 FEET BELOW BASEMENT SLAB
ELEVATION. BENTONITE OR 60 ML LIQUID
WATERPROOF MEMBRANE AS MFR. BY ANTI -HYDRO
OR EQUAL SHALL BE USED IF WATER TABLE IS
HIGHER. CONTRACTOR SHALL VERIFY WATER TABLE
IN THE FIELD.
DIVISION 4
UNIT MASONRY:
CONCRETE BLOCK (MIN. COMPRESSIVE STRENGTH:
1800 PSI):
PROVIDE NORMAL WEIGHT (125 LBS/CU. FT.) HOLLOW
LOAD BEARING BLOCK CONFORMING TO ASTM C90,
GRADE N-1.
INSTALLATION SHALL FOLLOW NATIONAL CONCRETE
MASONRY INSTITUTE'S RECOMMENDATIONS.
LAY WALLS IN RUNNING BOND PATTERN, UNLESS
OTHERWISE INDICATED.
DO NOT USE LESS THAN ONE HALF -MASONRY
MODULE.
TIE INTERSECTING WALLS WITH TRUSS TYPE
REINFORCING 16" O.C. VERTICALLY TO EXTEND 2'
ABOVE FOR ALL MASONRY CONSTRUCTION BELOW
GRADE.
REINFORCING:
TRUSS TYPE, CONTINUOUSLY WELDED WIRE AS
MANUFACTURED BY DURO-WALL OR EQUAL, 9GA;
FOLLOW MANUFACTURER'S INSTALLATION DETAILS.
PROVIDE MISC. ANCHORS AND TIES AS REQUIRED.
MINIMUM 14GA GALVANIZED STEEL OR 3/8"
DIAMETER GALV. STEEL ROD.
MORTAR:
USE TYPE "M" MORTAR CONFORMING TO ASTM C-270
ALL MORTAR SHALL BE MIXED A MINIMUM OF 5
MINUTES IN A MECHANICAL BATCH MIXER. DO NOT
RE -TEMPER AFTER 2 HOURS HAS ELAPSED. DO NOT
USE MORTAR, WHICH HAS ELAPSED. DO NOT USE
MORTAR, WHICH HAS BEGUN TO SET.
MAINTAIN A CONSTANT JOINT WIDTH THROUGHOUT
THE WORK. UNLESS OTHERWISE INDICATED OR
NOTED. JOINTS SHALL BE A MINIMUM '/4" WIDE.
MORTAR MATERIALS SHALL BE AS FOLLOWS:
-PORTLAND CEMENT: CONFORM TO ASTM C-150, TYPE
I.
-QUICKLIME: CONFORM TO ASTM C-5, PLANT MIXED
ONLY AND THOROUGHLY SLAKED PRIOR TO USE.
MAX MAGNESIUM OXIDE=8%
-HYDRATED LIME: CONFORM TO ASTM C-207, TYPE S.
-AGGREGATE: CONFORM TO ASTM C-144, OR C-404,
SIZE #2. AGGREGATE SHALL NOT EXCEED FOUR
TIMES THE PORTLAND CEMENT.
-WATER: POTABLE
-MOISTURE RESISTANT ADDITIVE: AMMONIUM
STEZRATE, ALUMINUM TRISTERATE, OR CALCIUM
STEARATE.
DIVISION 5
MISC. METALS:
STEEL WORK, IN GENERAL, SHALL CONFORM TO THE
FOLLOWING AMERICAN INSTITUTE OF STEEL
CONSTRUCTION STANDARDS.
-CODE OF STANDARD PRACTICE FOR BUILDERS AND
BRIDGES
-SPECIFICATIONS FOR THE DESIGN, FABRICATION,
AND ERECTION OF STRUCTURAL STEEL BUILDINGS,
INCLUDING THE COMMENTARY AND SUPPLEMENTS.
-SPECS FOR STRUCTURAL JOINTS USING ASTM A-325
OR A-490 BOLTS.
COMPLY WITH THE FOLLOWING AMERICAN WELDING
SOCIETY STANDARDS:
AWS D1.1 STRUCTURAL WELDING CODE
AWS D12.1 REINFORCING STEEL WELDING CODE
COMPLY WITH ASTM A-6, GENERAL REQUIREMENTS
FOR DELIVERY OF ROLLED STEEL PLATES, SHAPES,
SHEET PILING, AND BARS FOR STRUCTURAL USE.
CONFORM TO VARIOUS ASTM STANDARDS, AS NOTED,
AND ALL REQUIREMENTS OF THE GOVERNING
AUTHORITIES.
MATERIALS PROPERTIES:
1. STRUCTURAL STEEL SHAPES, PLATES, AND BARS
SHALL BE ASTM A-36.
2. COLD FORMED STEEL TUBING SHALL CONFORM
TO ASTM A-501
3. STEEL PIPE: ASTM A-53, TYPE E OR S, GRADE B.
BLACK FINISH, EXCEPT WHERE INDICATED TO BE
GALVANIZED.
4. ANCHOR BOLTS, ASTM A 307, GRADE A,
NON -HEADED TYPE.
5. ALL STEEL SHALL RECEIVE ONE OF RED OXIDE
PRIMER AFTER FABRICATION IN SHOP.
ERECTOR SHALL PROVIDE ADEQUATE TEMPORARY
BRACING FOR LATERAL STABILITY UNTIL THE
STRUCTURE IS FULLY BRACED BY THE INSTALLATION
OF PERMANENT STRUCTURE:
DIVISION 6
WOOD:
STRUCTURAL LUMBER:
ALL STRUCTURAL LUMBER SHALL BE CONSTRUCTION
GRADE DOUGLAS FIR -SURFACE DRIED TOMAX. 14%
MOISTURE CONTENT, STRESS GRADED LUMBER.
LUMBER SHALL HAVE THE FOLLOWING MINIMUM
STRESS PROPERTIES:
FB = 900 PSI
FV = 75 PSI
E = 1,700,000 SINGLE USE
ALL STRUCTURAL LUMBER SHALL COMPLY WITH
AND BE ERECTED IN ACCORDANCE WITH THE
NATIONAL FOREST PRODUCTS ASSOCIATION'S
NATIONAL DESIGN SPECIFICATION FOR WOOD
CONSTRUCTION, LATEST EDITION.
/ll�i11 T :-�I3.Y;lL�Li>f3sI71�u1:1.�;�f7
PROVIDE JOIST HANGERS FOR ALL FLUSH FRAMED
CONDITIONS, AS MANUFACTURED BY SIMPSON, TECO
OR EQUAL. INSTALL IN ACCORDANCE WITH
MANUFACTURER'S INSTRUCTIONS.
ALL FLOOR JOIST SHALL BE BRIDGED AT MID -SPAN
OR AT INTERVALS NOT TO EXCEED 8 FEET. METAL,
SOLID WOOD BLOCKING, AND (2) 5/4" X 3" BRIDGING IS
ACCEPTABLE.
ALL WALL OPENINGS, 4 FEET WIDE OR LESS, SHALL
HAVE DOUBLE STUDS AT JAMBS; SPANS WIDER THAN
FOUR 4 FEET SHALL HAVE DOUBLE STUDS FOR
HEADER BEARING PLUS JAMB STUD.
JOISTS SHALL BE DOUBLED AROUND ALL OPENINGS,
UNDER ALL PARALLEL WALLS AND PARTITIONS, AND
AT CANTILEVERS BEYOND THE FOUNDATIONS WALL.
TYPICAL INTERIOR NEW, NON -BEARING PARTITIONS
SHALL BE 2X4 STUDS AT 16" O.C. WITH 5/8"
SHEETROCK. TAPE, SPACKLE AND FINISH AS
SPECIFIED.
TYPICAL EXTERIOR WALLS: NEW CONSTRUCTION
SHALL BE 2X6 AT 16" O.C.
MUD SILL SHALL BE OF WOLMANIZED LUMBER 2X8
PLATE, SECURE TO FOUNDATION WALL WITH''/Z'
DIAMETER ANCHOR BOLTS, MAX. 6-0" O.C., AND MAX.
2 FEET FROM CORNERS.
PROVIDE LINTELS OR HEADERS AT ALL OPENINGS,
WHETHER OR NOT INDICATED ON THE PLANS.
HEADERS AT NON -BEARING CONDITIONS SHALL BE AS
FOLLOWS:
1F 4'-0" OR LESS...................................3-1/2" X 9-1/2"
LVL
IF 6-0" OR LESS...................................3-1/2" X 11-7/8"
OR
5-1/4" X 9-1/2" LVL
1F 8'-0" OR LESS...................................5-1/4" X 11-7/8"
LVL
IF A HEADER IS NOT INDICATED AT A BEARING
CONDITION, INFORM THE ARCHITECT BEFORE
PROCEEDING.
ALL WALLS (EXTERIOR) SHALL BE BRACED AGAINST
LATERAL LOADS BY STRUCTURAL SHEATHING, 16 GA.
STEEL STRAPPING, OR LET IN 1X4 CORNER BRACING.
MICROLAM:
SCOPE:
THIS WORK INCLUDES THE COMPLETE FURNISHINGS
AND INSTALLATION OF ALL "MICRO -LAM" LUMBER
BEAMS AS SHOWN IN THE DRAWINGS, HEREIN
SPECIFIED AND NECESSARY TO COMPLETE THE WORK.
MATERIALS:
THE MICRO -LAM LUMBER BEAMS SHALL BE
MANUFACTURED FROM MICRO -LAM BRAND
PARALLEL LAMINATED VENEER LUMBER UTILIZING
I/10" OR 1/8" THICKNESS DOUGLAS FIR VENEER GLUED
UP IN A CONTINUOUS PIECES WITH ALL GRAIN
PARALLEL WITH THE LENGTH OF THE MEMBER.
LAMINATED VENEER LIMBER SHALL BE OF SINGLE
ONE-PIECE LENGTH, FREE OF RINGER JOINTS, SCARF
JOINTS OR MECHANICAL CONNECTIONS IN FULL
LENGTH.
MEMBERS:
VENEERS SHALL BE DRIED AS REQUIRED. ADHESIVE
USED TO LAMINATE THE VENEER SHALL BE
WATERPROOF, MEETING THE REQUIREMENTS OF
ASTM D-2559-76, UNIFORMLY APPLIED TO THE VENEER
AT THE REQUIRED SPREAD RATE.
DESIGN:
MICRO -AM LUMBER BEAMS SHALL BE DESIGNED TO
MEET THE DIMENSIONS AND LOADS INDICATED ON
THE PLANS. ALL DESIGNS SHALL BE IN ACCORDANCE
WITH STANDARD ENGINEERING PRACTICE.
COMPLETE DESIGN CALCULATION SHOWING MEMBER
FORCES AND STRESSES AND ALLOWABLE LOAD ARE
TO BE AVAILABLE UPON REQUEST FOR EACH
MICRO -LAM LUMBER DESIGN. THE DESIGN OF THE
MICRO -LAM LUMBER BEAMS IS TO BE UNDER THE
SUPERVISION OF A REGISTERED PROFESSIONAL
ENGINEER AND IN ACCORDANCE WITH THE NRB
ACCEPTANCE, AND PROVISIONS OF THE NATIONAL
DESIGN SPECIFICATION FOR WOOD 1984.1,
PROTECTION:
THE MICRO -LAM LUMBER BEAMS, LIKE ANY OTHER
WOOD PRODUCT, SHALL BE EL
PROTECTION:
THE MICRO -LAM LUMBER BEAMS, LIKE ANY OTHER
WOOD PRODUCT, SHALL BE EXERCISED DURING
HANDLING TO PREVENT DAMAGE TO THE BEAMS.
HARDWARE:
ALL HARDWARE IS TO BE FABRICATED BY OTHERS
ACCORDING TO DETAILS CONTAINED IN THE
CONTRACT DRAWINGS.
INSTALLATION:
THE MICRO -LAM LUMBER BEAMS ARE TO BE
INSTALLED IN ACCORDANCE WITH THE PLANS.
TEMPORARY CONSTRUCTION LOADS BEYOND LIMITS
INDICATED THEREON ARE NOT PERMITTED. HOLES,
CUTS OR NOTCHES NOT PREVIOUSLY APPROVED BY
THE ENGINEER SHALL NOR BE MADE. THE FINAL
ERECTION OF THE MICRO -LAM LUMBER BEAM SHALL
BE UNDER THE DIRECTION OF QUALIFIED
CONSTRUCTION SUPERVISOR.
LATERAL NAIL HOLDING AND WITHDRAWAL ARE AS
PROVIDED IN THE CODE FOR DOUGLAS FIR SAWN
LUMBER. NAILS INSTALLED PARALLEL TO THE GLUE
LINES ON THE NARROW FACE SHALL NOT BE SPACED
CLOSER THAN 4 INCHES FOR 10-PENNY COMMON
NAILS AND 3 INCHES FOR 8-PENNY COMMON NAILS.
NAILS INSTALLED PERPENDICULAR TO THE GLUE
LINES ON THE WIDE FACE SHALL BE INSTALLED IN
ACCORDANCE WITH THE CODE. THESE NAILING
SPECIFICATIONS ARE BASED ON A MEMBER AT LEAST
3/4" THICK AND 3-1/2" WIDE. HOLDING POWER OF
BOLTS INSTALLED PERPENDICULAR TO THE GLUE
LINES IS AS PROVIDED IN THE CODE FOR DENSE
DOUGLAS FIR.
SPECIFIC APPROVAL IS REQUIRED FOR OTHER THAN
NAILED AND BOLTED CONNECTIONS.
STRUCTURAL PROPERTIES:
E = 2,000,000 FB = 2,800 PSI
NO SUBSTITUTES ARE ACCEPTABLE, UNLESS
SPECIFICALLY NOTED BY ENGINEER.
PLYWOOD:
ROOF SHEATHING SHALL BE CDX 2410 PLYWOOD, 5/8"
FOR SHEATHING SPANNING 16" OR LESS, AND
OTHERWISE.
FLOOR SHEATHING SHALL BE 32/16" STRUCTURAL I &
II C-D EXTERIOR, 3/4" THICK APA RATED, T&G, GLUED
AND NAILED.
ALL PLYWOOD SHALL BE GRADE MARKED AND MEET
THE STANDARDS OF AMERICAN PLYWOOD
ASSOCIATION. (APA)
DIVISION 7
THERMAL AND MOISTURE PROTECTION:
ROOFING:
DIMENSIONAL ASPHALT ROOFING SHINGLES, COLOR
AS SELECTED BY OWNER AND ARCHITECT.
IRKIIJIIMMKiIN
SHALL BE FOIL FACED (TYPICAL)
INSULATION:
1. 2 X 6 WALLS = R-19
2. CEILING & ROOF = R-49
3. FLOORS OVER UNHEATED SPACES = R-30
NOTE: INSULATE ALL ATTIC SPACES AND ALL
EXTERIOR WALLS.
FLASHING:
FLASHING WORK SHALL INCLUDE ALL FLASHING
REQURED FOR A COMPLETE INSTALLATION OF NEW
ROOFING, TRIM, ENTRANCES, ALL INDICATED ON
DRAWNGS. REPAIR AND/OR REPLACEMENT OF
GUTTERS AND DOWNSPOUTS AS REQUIRED TO
CREATE A WATER TIGHT JOB.
FLASHING FOR ROOFING SHALL BE COPPER SHEET:
ASTM,160Z. (0.0216")(COLD ROLLED). SEPARATE ALL
DISSIMILAR METALS WITH BITUMINOUS COATING.
JOINTS TO BE SOLDERED.
DIVISION 8
DOORS AND WINDOWS:
WINDOWS: (SEE WINDOW SCHEDULE.)
WINDOWS BY LOW-E GLASS. SIZE AND FUNCTION AS
INDICATED -CONTRACTOR TO VERIFY SIZES, (ROUGH
OPENINGS) WITH MODEL NUMBERS PRIOR TO
ORDERING WINDOWS, AND TO REPORT ANY
DISCREPANCIES TO ARCHITECT.
PROVIDE AND INSTALL ALL INSECT SCREENS AND
HARDWARE AS REQUIRED.
ALL GLASS WITHIN 18" OF FLOOR TO BE TEMPERED.
DOORS: (SIZE AS INDICATED ON PLANS)
SKYLIGHTS: (AS INDICATED ON PLANS. UNLESS
OTHERWISE NOTED SKYLIGHTS TO BE BY
"ANDERSEN"-LOW-E GLASS.)
DIVISION 9
FINISH SCHEDULE:
INTERIOR WALLS AND CEILING: TAPE AND SPACKLE
DRYWALL, 3 COATS (I PRIME, 2 FINISH). TAPE SHALL
BE FIBERGLASS TYPE. WALLS AND CEILING TO BE
READY FOR PAINT. ALL DRYWALL SHALL BE
ATTACHED TO FRAMING WITH SCREWS, MAX. 12"O.C.
INTERIOR TRIM: ALL TRIM JOINTS TO BE FILLED WITH
WOOD FILLER AND SANDED READY FOR PAINT.
DIVISION 10
SPECIALTIES: IF USED, SPECIFIED ON PLANS.
DIVISION 11
EQUIPMENT:
APPLIANCES SUPPLIED BY OWNER AND INSTALLED
BY CONTRACTOR. CONFIRM REQUIRED
MECHANICAL/ELECTRICAL HOOK-UPS.
DIVISION 12
FURNISHINGS: NOT USED
DIVISION 13
SPECIAL CONSTRUCTION: NOT USED
DIVISION 14
CONVEYING SYSTEMS: NOT USED
DIVISION 15
MECHANICAL: PROVIDED BY HVAC
ENGINEER/ENGINEEER
f
3
4
V R CH
321 RIVERSIDE DR
RIVERHEAD, NY 11901
(516 )376-8594
Client Info
BRIAN & CHLOE SCHIELE
1510 Maple Lane
East Marion, NY
Project Info
LEGALIZE EXISTING FINISHED
BASEMENT & ROOF OVER EXISTING
DECK
1510 Maple Lane
East Marion, NY
cn
� Z
V) O w
Z :P
O o- U
U 0
Z
O
U
U)
Z
O
U
CV
O
v
GENERAL
NOTES
Drawn By
J.E.M.
Drawing No.
Checked By
J.E.M.
A-3
Sheet 3 of 3