I. NO 50ILSURCHAPGE PERMITTED WITHIN 4 FEETOF EXCAVATION AT THE SHALLOW END,OR 6 FEET OF EXCAVATION ATTHE DEEP END.
2. THIS POOL MEETS THE REQUIREMENT50FAN5VAPSP/ICC-5 AMERICANNATIONALSTANDARD FOP.RESIDENTIALINGROUNDSWIMMING k
10• d0' 10' POOLS'AND 1996 BOCA CODE-SECTION 421.DIVING EQUIPMENT 15 NOTALLOWED. O
3. SWIMMING POOL SHALL BECOMPLETELYANDCON11NUOLJSLYSURROUNDED WITH A BARRIER CONST ucrED LAW REQUIREMENTS OF
Q SECTION R326.4.2.1 THROUGH R326.42.6 OF THE NEW YORK STATE RESIDENTIAL CODE(2020)AND IN CONFORMITY WITH ALL SECTIONS LZ
OF THE TOWN OF SOUTHOLD CODE DWELLING WALL(S)MAY SERVE AS PARTOF THE POOL BARRIEKAS PER SECTION R326.4.2,8 AND
p CONDITION(1)ARE MET.OPERABLE WINDOWS IN THE WALL(S)USED ASA BARRIER SHALL HAVE SELF LATCHING DEVICE.ACCESS GATES 86
SHALL COMPLY..WITH SECTION R326.5.2 OF THE NYS PZIPEN71AL CODE(2020)AND BESELF CLOSING,SELF LATCH INC AND BE SECURELY `^
LOCKED WHEN POOL 15 NOT IN USE OR SUPERVISED.ALL GATES ARE TO OPEN AWAY FROM THE POOLAREA. J
4. DURINGCONSTRVCTIONTHECONTRACTOR5HALLERECTATEMPORARYBARRIERAROUNDTHEEXCAVATIONLAWTHECODEOFTHE O t`--
3� s•O• TOWN OF SOUTHOLD. 0
m H2O H2O x A S. POOL MUST BE EQUIPPED WITH AN APPROVED POOL ALARM CAPABLE OF DETECTING ENTRY INTO THE WATER AND 50VNDING AN }
AVDIBLEALAPLM UPON DETECTION THAT 15 AUDIBLE AT POOLSIDE AND INSIDE THE DWELLING.THE ALARM MV5TBEINSTALLED, V a3i
MAINTAINED AND USED IN ACCORDANCE WITH THE MANUFACTURERS IN5TRVCTIONS.THEALARM MU5TMEETASTM F2208 _Z IQ Z
¢ 'STANDARD SPECIFICATION FOR POOL ALARMS.THE DEVICE MUST OPERATE INDEPENDENT(NOTATTACHEDTOOR DEPENDENT ON)OF ry c
PERSONS, R'O
A �a
6. POOLSUCTION FITTINGS(D(CEPTFORSURFACESKIMMERS)MUSTBE PROVIDED WITH ACOVERTHATCONFORMSTOASME/ANSI T
'p A112.19.8MORA MINIMUM I8'x25'DRAIN GRATE ORA CHANNEL DRAIN SYSTEM. POOL CIRCULATION SYSTEM MUST BE EQUIPPED WITH
ATMOSPHERIC VACUUM RELIEF IN THE EVENTTHE GRATE COVERS LOCATED WITHIN THE POOL BECOME MISSING OR BROKEN.SUCH
VACUUM RELIEF SYSTEMS SHALL CONFORM WITH ASME A112.19.17 OR BE A GRAVITY SYSTEM APPROVED BY THE TOWN OF SOUTHOLD,
PLAN POOL SHALL BE PROVIDED WITH A MINIMUM OF 2 SUCTION FITTINGS OF THE ABOVE MENTIONED TYPE.THE SUCTION FITTINGS SHALL BE
B SEPARATED BY A MINIMUM OF 3'AND MV5T BE PIPED SUCH THAT WATER 15 DRAWN THROUGH THEM SIMULTANEOUSLY THROUGH A
N.T.S. VACUUM RELIEF-PROTECTED LINE TO THE PUMP(OR PUMPS) VACUUM/PRESSURE CLEANING FITTINGS SHALL BE IN AN ACCESSIBLE
POSITION,MIN]MUM OF 6'AND NO GREATER THAN 121 BELOW THE MINIMUM OPERATIONAL WATER LEVEL OR BEAN ATTACHMENT TO
THE SKIMMER/SKIMMERS.A AEOVIRED POOL ATMO5PH ERIC VACUUM RELIEF SYSTEM SHALL BE INSTALLED AS PER NYS RE5IDENTIAL CODE
18'VINYL COVERED STEPS R326.63(2020)AND IN ACCORDANCE WITH INC.VILLAGE CODE.
7. ;ALL ELECTRICAL WORK SHALLCOMPLY WITH THE REQUIREMENTSOFNFPA70(NEC)PRINCIPALLY ARTICLE 680 AND THE NYS tJ
N RESIDENTIAL CODE SECTIONS,4201 THROUGH 4206.ALL ELECTRICAL DEVICES MUST BE APPROVED BY UNDERWRITERS LABORATORIES AND GJ
BE PROTECTED BY A GROUND FAVLT CURRENT INTERRUPTER(GFCI)CURRENT CARRYING ELECTRICAL CONDUCTORS EXCEPT FOR THOSE 'C3
PROVIDING POWER TO POOL LIGHTING AND POOL EQUIPMENTSHALL MEETTHE SEPARATION REQUIREMENTS OF TABLE E4203.5.ALL
+- METAL ENCLOSURES,FENCES OR RAILINGS NEAR OR ADJACENTTO.THE SWIMMING POOL THAT MAY BECOME ELECTRICALLY CHARGED
rro s sANv BOTTOM DUE TO CONTACT WITH AN ELECTRICAL CIRCVITSHALL BE EFFECTIVELY GROUNDED. to
8. WATER SOURCE FILLING THE POOL SHALL BE EQUIPPED WITH A BACKFLOW PROTECTION DEVICE LAW NYS PLUMBING CODE 608. QJ
S ECTI O N A 9, ALL PIPING IS DIAGRAMMATIC UNLESS OTHERWISE STATED. �o v
N.T.S. 10. WALKS IF PROVIDED SHALL BE NONSLIP AND SLOPE AWAY FROM POOLEDGE. O N�
o V -, Z
WATER LINE TOP OF WALL 11. A MEANS OF EGRESS FOR DEEP AND SHALLOW ENDS MVST BE PROVIDED LAW ANSI/APSP/ICC-5 SECTION 6.
4' 0, 4, 12: CONTRACTOR TO PLACE THE POOL LAW TOWN.OF SOUTHOLD CODE SETBACKS. O O . Ln
C
13. ALL DRAINAGE FROM THE POOL5HALL BE MAINTAINED ON THE SUBJECT PROPERTY.
15. THE DESIGN IS BASED ON A DRAINAGE SOIL WITH<10%SILT.GROUND WATER SHALL NOT EXIST WITHIN THE EXCAVATION. IF GROUND
WATER EXISTS WITHIN 6'-0'FROM GRADE DEWATERING FACILITIES WILL BE REQUIRED.
In
16. ALL GAS AND OIL HEATERS(IF INSTALLED)FOR THE INGROUND SWIMMING POOL SHALL BE NATIONAL APPLIANCE ENERGY ei
S ECTI O N B CONSERVATION ACT(NAECA)COMPLIANT. POOL HEATERS SHALL BETE LAW ANSI 721.56 AND SHALL BE INSTALLED LAW
MANUFACTURERS SPECIFICATIONS OIL FIRED POOL HEATERS 5HALL BE TESTED IAW UL726. POOL HEATERS SHALL BE LOCATED OR
N.T.5. GUARDED TO PROTECTAGAI N5TACCIDENTAL CONTACT'OF HOT SURFACES BY PERSONS. POOL HEATERS SHALL BE PROVIDED WITH
TEMPERATURE AND PRESSURE-RELIEF VALVES.FOR HEATERS NOT PROVIDED WITH AN INTEGRAL BYPASS SYSTEM.A BYPASS LINE SHALL BE
INSTALLED FROM INLET TO OUTLET TO ADJUST WATER FLOW THROUGH THE HEATER. POOL HEATERS SHALL BE PROVIDED WITH THE
FOLLOWING ENERGY CONSERVATION MEASURES:
2,_2•
CHECKVALVE 16.1 ATLEA5TONE THERMOSTAT SHALL BE PROVIDED FOR.EACHHEATING SYSTEM.
1D' Q.
COPING AND WALKWAY. C
(6Y OTHERS) 16.2 ALL POOL HEATERS SHALL BE EQUIPPED WITH AN ON-OFF SWITCH MOUNTED FOR EASY ACCESS TO ALLOW SHUTTING OFF THE
PUMP FROM SKIMMER GRADE OPERATION OF THE HEATER WITHOVTADJVSTTNG THE THERMOSTAT SETTING AND TO ALLOW RESTARTINGWITHOUTRELIGHTINGTHE rn
WATMUNE PILOTLIGHT.
CO
'a a
�ouPOSAU � ;t.•j:'•,;' 163 HEATED SWIMMING POOLS SHALL BE EQUIPPED WITH A POOL COVER(EXEMPTED FROM THIS REQVI REM ENTARE OUTDOOR POOLS
DERIVING 20%OF THE ENERGY FORHEATING FROM RENEWABLE SOURCESAS COMPUTED OVERANOPERATINGSEASON)
DRYWELL / VNDMVRBED EARTH 16.4 TIME CLOCKS SHALL BE INSTALLED 50 THE PUMP CAN BE SETTO RUN DURING OFF-PEAK ELECTRICAL DEMAND PERIODS AND CAN BE SET a>.CO= "�
/ 3WOPSI POURED CONC. .s; TO RUN THE MINIMUM TIME NECESSARY TO MAINTAIN THE POOL WATER IN A CLEAN AND SANITARY CONDITION LAW APPLICABLE __ m; o 0
/// SANITARY CODE OF NEW YORK STATE.
VALVE O SA'REIWL 2)TYP. - "
NNYLUNER 17, THIS DRAWING 15 FOR STRUCTURAL SHELL ONLY.ALL ACCESSORIES AND APPURTENANCES ARE DEFINED,BY_OTHERS. -_! = E o 3
o m
2•T04•SAND %• 1B. BACKFILL WITH CLEAN EARTH,FREEOF ROOTS AND DEBRIS. DO NOTALLOW THE HEIGHT OFBACKFILLTO EXCEED THE HEIGHTOF THE
W `� o m
FILTER WATER IN THE POOL BY MORE THAN 8-,OR THE WATER TO EXCEED BACRFILL BY MORE THAN S. c -
~ 19. PLACE CONCRETE ON SANDY TO LOAM SOIL REMOVE ANY CLAY DEPOSITAND REPLACE,W/COMPACTED CLEAN BACKFILL.
L 9
/ TO RETMNS 20. THERE IS NO MAIN DRAIN IN THIS POOL SUCTION FOR POOL WATER CIRCULATION 15 PROVIDED BY THE SKIMMERS ONLY.THI5 MEETS C�
!'° CHECK VALVE J REQUIREMENTS OF THE NYS RESIDENTIAL CODE-SECTION R326.5 FOR ENTRAPMENT PROTECTION. of:
A 1 =
PLUMBING SCHEMATIC 21. THE POOL WAS DESIGNED LAW THE FOLLOWING: ER T'HVQ
N.rs. WALL SECTION 21.1. THE NEW YORK STATE RESIDENTIAL CODE-SECTION R326(2020)
212. THE NEW YORK STATE ENERGY CONSERVATION CONSTRUCTION CODE-SECTION R403.10(2020)
6 y N.T.S. 21.5. THE NEW YORK STATE FUEL GAS CODE(2020) I
21A. THENEWYORK STATE SANITARYCODE, co
� a q
21.5. ANSI/APSP/ICC-5 STANDARD FOR RESIDENTIAL IN-GROUND SWIMMING POOLS.
21b. BOLA CODE-SECTION d21. r I� � 1
.21.7. CODE OF THE TOWN OF SOUTHOLD. � !
22. ALL BACKWASH TO BE SELF-CONTAINED ON-SITE. �� O • ,�
23. POOL TO BE EQUIPPED WITH AN AUTOMATIC POOLCOVER. a0[� 9•�