Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
51388-Z
tOf SOppyo`o Town of Southold * * P.O. Box 1179 0 53095 Main Rd Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 46052 Date: 03/24/2025 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 190 Pheasant PI Greemort, NY 11944 Sec/Block/Lot: 53.4-44.36 Conforms substantially to the Application for Building Permit heretofore,filed in this office dated: 11_/14/2024 Pursuant to which Building Permit No. 51388 and dated: 11/18/2024 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: Roof mounted solar panels to an existing single-family dwelling as applied for. The certificate is issued to: Daniel Halioua,Rebecca Grossman-Cohen Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: 51388 3/20/2025 PLUMBERS CERTIFICATION: A ho ' Signatur owsoulyo�o TOWN OF SOUTHOLD * BUILDING DEPARTMENT `� TOWN CLERK'S OFFICE Wall SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 51388 Date: 11/18/2024 Permission is hereby granted to: Daniel Halioua 377 6th Ave Brooklyn, NY 11215 To: Install roof mounted solar panels to an existing single-family dwelling as applied for per manufacturers specifications. Premises Located at: 190 Pheasant PI, Greenport, NY 11944 SCTM#53.-4-44.36 Pursuant to application dated 11/14/2024 and approved by the Building Inspector. To expire on 11/18/2026. Contractors: Required Inspections: Fees: SOLAR PANELS $100.00 CO-RESIDENTIAL $100.00 ELECTRIC -Residential $125.00 Total $325.00 ---- S. --------------- Building Inspector oF so�ryol � o Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 G Q Southold,NY 1 1 97 1-0959 �y��UNTY,Nc� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Daniel Halioua Address: 190 Pheasant Place City: Greenport St: NY Zip: 11944 Building Permit#: 51388 Section: 53 Block: 4 Lot: 44.36 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: Harvest Power LLC License No: 68518ME SITE DETAILS Office Use Only Indoor 5F Basement r Service Solar r Outdoor W 1st Floor r Pool r Spa F Renovation F 2nd Floor r Hot Tub r Generator F Survey r5ol Attic ri I Garage Battery Storage I—. INVENTORY Service 1 ph (— Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph r Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'-LED Exit Fixtures Other Equipment: 23kW Roof Mounted PV Solar Energy System w/ (50)REC460AA PureRx Modules, 100A Fused Disconnect, Combiner Panel w/ (5)220Breakers, Lineside Tapped In Main Panel Notes: Solar Inspector Signature: X Date: March 20, 2025 Sean Devlin Electrical Inspector sean.devlina-town.southold.ny.us 190PheasantPISolar J 3 OF SOUIyO� I * TOWN OF SOUTHOLD BUILDING DEPT. coo 631-765-1802 INSPECTION [ ] FOUNDATION 1 ST/ REBAR { } ROUGH PLBG. [ ] FOUNDATION-2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ FINAL C5049- [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: DATE INSPECTOR OF SOUTyO� I C) f f �Lo� ,ram �l � ---- - # TOWN OF SO.UTHOL BUILDING DEPT. °`y�o�►�N 631-765-1802 INSPECTION [ ]' FOUNDATION 1ST/-REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION . [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) LECTRICAL (FINAL) ] CODE VIOLATION [ ] PRE C/O [ ]. RENTAL REMARKS: e v�Scm aA I , DATE GL - INSPECTOR T_I OF SOUTyO� 2�6 6 D ��0lJd ?J SOU DEPT.OF 631-765-1802 . -INSPECTION ' [ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) . .ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: DATE INSPECTOR FIELD INSPECTION REPORT I DATE COMMENTS FOUNDATION (1ST) ------------------------------------- C FOUNDATION (2ND) _o o ROUGH FRAMING& PLUMBING -- it r �n INSULATION PER N.Y. STATE ENERGY CODE FINAL ADDITIONAL COMMENTS - b`Z rn �k — x t= b H oauFF°t rra z TOWN OF SOUTHOLD-BUILDING DEPARTMENT Towri'Hall Annex 54375.Main Road P. 0. Box 1179 Southold,NY 11971--0959 t -Telephone(631)7.65-1802 Fax(631) 765-9562'https:l?w. ?vw.southoldtownny.gov :Date Received APPLICATION FOR BUILDING PERMIT _ 0 P S i .For Office Use Only PERMIT N0. - Bufld'ing Inspector. - t L Applications and forms must be filled out ri their entirety.Incomplete applications will not;be accepted. Where the Applicant is not the owner,an n Owner's.Authorization form`(Page2)shall be completed: Date: 11/5/2024 ; QW.NER(S)-OF PROPERTY: Name: Daniel Halioua Sam#1o00- 53-� �`� ✓o Project Address: 190 Pheasant Place, Greenport, NY 11944 Phone#: (917) 42e-80e5 Email: dhalioua@gmail.com Mailing Address: 190 Pheasant Place, Greenport, NY 11999 CONTACtPERSON ` Name: Katelyn'Tornetta Mailing Address: 2.94.1 Sunrise Hwy, Islip Terrace, NY 11752 Phone#: (631) 647-3402 , Email: hppermitting@harvestpower.net DESIGN PROFESSIONAL.INFORMATIONc Name: Michael Dunn, R.A. Mailing Address: 256 Orinoco -Dr,.' Brihtwaters, NY 11718 Phone#: (631) 665-9'619 Email: B'ayblueprint@aol. com CONTRACTOR INFORMATION: Name: Harvest. Power LLC ; Mailing Address: 2941 Sunrise 'Hwy, Islip Terrace, NY 11152 . Phone# (631) 647-3402 Email:- hpperinitting@harvestpower.net DESCRIPTION OF'PROPOSED CONSTRUCTION El New Structure ❑Addition ®Alteration El Repair.El Derriblition Estimated Cost of Project: OQther - Will the lot be re-graded? ❑Yes ®No Will excess fill be removed from premises?.OYes.XNo 1 , PROPERTY ,,OR(VIATION t, Existing use of property: Residence Intended use of property:; (no change) Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? Dyes ®No IF YES, PROVIDE A COPY. ® Check Box After Reading.`Thebwner/contractor/design professional is responsible for all drainage and storm water issuevas provided by% Chapter 236 of the Town edde. APPLICATION IS HEREBY MADE to'the Building Department for the issuance of,a�Bui181ng Permit pursuant to the Building zone' ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,.Ordinarices or Regulations,for the construction`of buildings, " additions,alterations or for removal or demolition as herein described.The'applicant agrees to•comply with alPapplicable laws,ordinances,building code, housing,code and regulations and to adriit'authorized inspectors_on premises`and m building(s)fornecessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210AS zf the New York State Penal Law,_. Application Submitted By( rint name): Vc4UJyx—Vurc%e-� � Authorized Agent ❑Owner Signature of Applican • Date: i 11s'110l� i STATE OF NEW YORK) SS: COUNTY 0F,___.����Q r being duly sworn, deposes and says that(s)he is the applicant (Name of individual s ning contract) above named, (S)he is the P (Contra tor, Agent, Corporate Officer,etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this y �U\-)al ,�r' ;20 da of DINA LANZA Notary Public NOTARY PUBLIC,STATE OF NEW YORK Registration No.01LA6034714 E InSuCounty CommissionQualified May � PF OPERTY OWNER AUTHORIZATION ;(Wheretffe applicant is,n-5T., :owner), (.::. avXA `( `D L4(A residing at lot o Pke ci Sc, fj Qct, �,13�``�'` (L do hereby authorize 46- C to apply on my behalf to the Town of Southold Building Department for approval as described herein. l '4- 2 Owner's Sig t ate Print Owner's Name 2 - - - - CONSENT TO INSPECTION Daniel.Halioua ,the'undersigned, do(es)hereby state- the Name(s) That the undersigned (is) (are)the owner(s)of the premises in-the Town of Southold,located at 190 Halioua place, Greenport, NY 11944 which is shown and designated dwthe Suffolk County Tax Map as District 1000, Section 53 , Block 44 ,Lot 44.36 . .,That the undersigned(has)(have)filed, or cause to be fled,an application in the Southold Town-Building Inspector's Office for the following! Installation of a Za kw solar system with.60J REC 460BBB'roof.mounted panels That the undersigned do(es) herebygive consent to the Building Inspectors of the Town of Southold to enter upon the above described property, including any and 411 buildings located thereon, to conduct such inspections as they may deem necessary with respect to the aforesaid application,including inspections to determine that said premises comply with all of the laws;ordinances,rules and regulations of the Town of Southold. The undersigned, in consenting to such inspections;,do(es)so with the knowledge and understanding that any information obtained in the conduct of such inspections may be used in subsequent prosecutions for violations of the laws.:ordinances,rules or regulations of the .Town of Southold. JI Daniel Halioua (Sri, ature) :(Pant Bttilding_)neoartment Apolkation AUTH6RIZATIOiV . (Where the Applicant is not the Owner) j, Daniel Aalioua residing at _1H Pheasant Place (Point property ownei°'s'name) (Mailing Address) Gieenpor-t do hereby authorize Katelyn'Toinetta (Agent) Harvest Power LLC to apply,on my behalf to the Southold Building Department. y" tiers, L gnatli Daniel Halioua c($1?C1Ilt QWItLI S,�,I�at1tG� . OS�FFQj,�C BUILDING DEPARTMENT-Electrical Inspector TOWN OF SOUTHOLD COTown Hall Annex- 54375 Main Road - PO Box 1179 o • Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 l ' iamesh(-southoldtownny.gov— seand(cD-southoldtownny_,gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Company Name: Harvest Power LLC Electrician's Name: Carlo Lanza License No.: ME-68518 Elec. email:hppermitting@harvestpower.net Elec. Phone No: (631) 647-3402 ❑I request an email copy of Certificate of Compliance Elec. Address.: 2941 Sunrise Highway, Islip Terrace, NY 11752 JOB SITE INFORMATION (All Information Required) Name: Daniel Halioua Address: 190 Pheasant Place, Greenport, NY 11944 Cross Street: Kerwin Blvd Phone No.: (917) 428-8085 Bldg.Permit#: 5 e '2)8g email:dhalioua@gmail.com Tax Map District: 1000 Section:53 Block: 4 Lot:44.36 BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Installation of a 23 kW solar PV system with (50) REC460AA roof-mounted panels. Square Footage: Circle All That Apply: Is job ready for inspection?: ❑ YES 0 NO ❑Rough In Final Do you need a Temp Certificate?: ❑� YES ❑ NO Issued On Temp Information: (All information required) Service SizeFV_11 Ph❑3 Ph Size: 200 A # Meters 1 Old Meter# ❑New Service❑Fire Reconnect[:]Flood Reconnect,❑Service Reconnect ✓❑Underground❑Overhead # Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION Suffolk County Dept.of Labor,Licensing&Consumer Affairs 9—N HOME IMPROVEMENT LICENSE Name CARLO LANZA ` Business Name r Harvest Power LLC This certifies that the bearer is duly licensed License Number H-48165 by the County of suffolk issued: 11/18/2010 y�pywvrT. Roge►rj, Expires: 11101/2026 Commissioner Client#: 110076 HARVPOW ACORDTM CERTIFICATE OF LIABILITY INSURANCE DATE(MMIDDIYYYY)4/16/2024 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW.THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT:If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement.A statement on this certificate does not confer any rights to the certificate holder in lieu of such endorsement(s). PRODUCER NAME: Commercial Support Edgewood Partners Ins.Center PHONE 631-390-9700 Fax A/C No Ext: A/C,No): 40 Marcus Drive 3rd Floor E-MAIL ADDRESS: NEcert aPificates Icbrokers.com Melville,NY 11747 INSURER(S)AFFORDING COVERAGE NAIC# INSURER A:James River Insurance Company 12203 INSURED INSURER B:Lloyd's Of London Harvest Power LLC,Friendly INSURER C Construction Company Inc,EZ Flashing LLC INSURER D 2941 Sunrise Hwy INSURERS: Islip Terrace,NY 11752 INSURER F COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACTOR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADDL SUER POLICY EFF POLICY EXP LIMITS LTR INSR WVD POLICY NUMBER MM/DDIYYYY MM/DD/YYYY A X COMMERCIAL GENERAL LIABILITY 000711808 04/15/2024 04/15/2025 EACH OCCURRENCE $1 OOO 000 CLAIMS-MADE a OCCUR PREMISES ERENTED ccnce $50 000 X Contractual Liab. MED EXP(Any one person) sExcluded X $5,000 Ded. PERSONAL&ADV INJURY $1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE s2,000,000 POLICY I X JECOT LOC PRODUCTS-COMP/OP AGG $2,000,000 OTHER: $ AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT Ea accident $ ANY AUTO BODILY INJURY(Per person) $ OWNED SCHEDULED BODILY INJURY(Per accident) $ AUTOS ONLY AUTOS HIRED NON-OWNED PROPERTY DAMAGE $ AUTOS ONLY AUTOS ONLY Per accident $ A X UMBRELLA LIAB X OCCUR 000711797 04/16/2024 04/15/2026 EACH OCCURRENCE s4,000,000 EXCESS LIAB CLAIMS-MADE AGGREGATE s4,000,000 DED RETENTION$ $ WORKERS COMPENSATION PER OTH- AND EMPLOYERS'LIABILITY Y/N TAT R ANY PROPRIETOR/PARTNER/EXECUTIVE E.L.EACH ACCIDENT S OFFICER/MEMBER EXCLUDED? ❑ N/A (Mandatory in NH) E.L.DISEASE-EA EMPLOYEE $ If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ A Pollution Liab. 000711808 04/16/2024 04/15/202 $1MM Ea Claim/$1MM Agg B Professional Liab HPL230064 04/15/2024'04/15/202 $2MM Ea Claim/$2MM Agg $1OK Ded Ea Claim DESCRIPTION OF OPERATIONS/LOCATIONS I VEHICLES(ACORD 101,Additional Remarks Schedule,may be attached if more space Is required) Evidence of Insurance CERTIFICATE HOLDER CANCELLATION Town of Southold SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN P.O:Box 970 ACCORDANCE WITH THE POLICY PROVISIONS. South Hold,NY 11964-0000 AUTHORIZED REPRESENTATIVE ©1988-2015 ACORD CORPORATION.All rights reserved. ACORD 25(2016103) 1 of 1 The ACORD name and logo are registered marks of ACORD #S6497815/M6497588 RH002 Suffolk County Dept.of Labor,Licensing&Consumer Affairs t MASTER ELECTRICAL LICENSE Name 4. CARLO P LANZA Business Name ThisThis ce�rtifies that the y Harvest Power LLC certifies bearer is duly licensed License Number ME-68518 by the County of suffolk Issued: 11/30/2023 Jefu,i fer Ca4>rera, Expires: 11/01/2025 Commissioner Client#: 110076 HARVPOW DATE(MM/DD/YYYY) ACORDTM CERTIFICATE OF LIABILITY INSURANCE 4/16/2024 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW.THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT:If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement.A statement on this certificate does not confer any rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT Commercial Support Edgewood Partners Ins.Center PHONEo 631-390-9700 FAX No A/C N Ext 40 Marcus Drive 3rd Floor E-MAIL SS: NEcertificates@epicbrokers.com Melville,NY 11747 INSURER(S)AFFORDING COVERAGE NAIC# INSURER A:James River Insurance Company 12203 INSURED INSURER B:Lloyd's of London Harvest Power LLC,Friendly INSURER C Construction Company Inc,EZ Flashing LLC INSURER D 2941 Sunrise Hwy INSURER E Islip Terrace,NY 11752 INSURER F COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACTOR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADDLSUBR POLICY EFF POLICY EXP LIMITS LTR INSR WVD POLICY NUMBER MM/DD/YYYY MM/DDIYYYY A X COMMERCIAL GENERAL LIABILITY 000711808 04/16/2024 04/15/2026 EACH OCCURRENCE S1.0001000 CLAIMS-MADE �OCCUR PREMISES Ea occcu D nce $60,000 X Contractual Liab. MED EXP(Any one person) $Excluded X $5,000 Ded. PERSONAL BADVINJURY $1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $2,000,000 PRO- ❑ PRODUCTS-COMP/OP AGG s2,000,000 POLICY JECTPRO- LOC OTHER: $ AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT Ea accident $ ANY AUTO BODILY INJURY(Per person) $ OWNED SCHEDULED BODILY INJURY(Per accident) $ AUTOS ONLY AUTOS HIRED NON-OWNED PROPERTY DAMAGE $ AUTOS ONLY AUTOS ONLY Per accident A X UMBRELLA LIAR X OCCUR 000711797 04/15/2024 04/16/2025 EACHOCCURRENCE s4,000,000 EXCESS LIAB CLAIMS-MADE AGGREGATE s4,000,000 DED RETENTION$ $ WORKERS COMPENSATION PER OTH- AND EMPLOYERS'LIABILITY Y/N ANY PROPRIETOR/PARTNER/EXECUTIVE E.L.EACH ACCIDENT $ OFFICER/MEMBER EXCLUDED? N/A (Mandatory in NH) E.L.DISEASE-EA EMPLOYEE $ If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ A Pollution Liab. 000711808 04/15/2024 04/15/202 $1MM Ea Claim/$1MM Agg B Professional Liab HPL230064 04/16/2024 04/16/202 $2MM Ea Claim/$2MM Agg $10K Ded Ea Claim DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES(ACORD 101,Additional Remarks Schedule,may be attached if more space is required) Evidence of Insurance CERTIFICATE HOLDER CANCELLATION Town of Southold SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN P.O.Box 970 ACCORDANCE WITH THE POLICY PROVISIONS. South Hold,NY 11964-0000 AUTHORIZED REPRESENTATIVE ©1988-2015 ACORD CORPORATION.All rights reserved. ACORD 25(2016/03) 1 of 1 The ACORD name and logo are registered marks of ACORD #S6497815/M6497588 RH002 APPROVED AS NOTED ELECTRICAL 2 B.P.# 3�� INSPECTION REQUIRED DATE: -� FEE a00-00 BY. NOTIFY BUILDING DEPARTMENT AT 631-765-1802 8AM TO'4PM FOR THE Additional FOLLOWING INSPECTIONS: Certification FOUNDATION-TWO REQUIRED FOR POURED CONCRETE May Be Required. ROUGH-FRAMING&PLUMBING INSULATION FINAL-CONSTRUCTION MUST 1 BE COMPLETE FOR C.O. CISSCOIf�Y1C - MY1Ug� tOca4cd ou450c ) ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW O�b�led and r, I YORK STATE. NOT RESPONSIBLE FOR 7 Awe SiSI�p� . DESIGN OR CONSTRUCTION ERRORS COMPLY WITH ALL CODES OF NEW YORK STATE&TOWN CODES AS REQUIRED AND CONDITIONS OF SOUTHOLDTOWNZBA SOUTHOLDTOWN PLANNING BOARD SOUTHOLD TOWN TRUSTEES N.Y.S.DEC SOUTHOLOHPC Graham Associates 256 Orinoco Drive, Suite A Brightwaters,NY 11718 Planning& Design (631)665-9619 November 5, 2024 Town of Southold Building Department 54375 Rt. 25 Southold, NY 11971 Re: Daniel Haliqua Residence 190 Pheasant Place Greenport, NY Proposed 23.00 kWDC, 19.00 kWAC PV System To Whom It May Concern, Please be advised that I have analyzed the existing roof structure at the above-mentioned premises and have determined that it is adequate to support the additional load of the solar panels and a 140 mph wind load and 20 psf snow load without overstress, in accordance with the following: The 2020 New York State Uniform Fire Prevention and Residential Building Code; Town of Southold Local Code, Long Island Unified Solar Permit Initiative, (LIUSPI); and 2020 National Electric Code NFPA 70/2020 National Electric Code including ASCE7-16 If you y further questions, do not hesitate to call. �3- 02981 cjQ� FOB Mic nn, RA PHOTOVOLTAIC ROOF MOUNT SY8TEM 50 MODULES-ROOF MOUNTED - 23.00 kWDC, 19.00 kWAC 11 190 PHEASANT PL, GREENPORT, NY 11944, USA HARVEST _ HARVEST POWER LLC - - — 2941 SUNRISE HIGHWAY ISLIP ACE,NY 11752 SYSTEM SUMMARY: SHEET INDEX TERRA GOVERNING CODES: 80, (N)50-REC SOLAR REC460AA PURE-RX(460W) MODULES -� RE ( )9893585 Hary PV-0 COVER SHEET S est owernet 2017 NATIONAL ELECTRICAL CODE(NEC) � (N)50-ENPHASE IQ8X-80-M-US MICRO-INVERTERS G 2020 BUILDING CODE OF NYS PV-1 SITE PLAN WITH ROOF PLAN !` (N)JUNCTION BOX G� � \ ti (E)200A MAIN SERVICE PANEL WITH (E)200A MAIN BREAKER 2020 RESIDENTIAL CODE OF NYS PV-1.1 ENLARGE VIEW (N) 100A FUSED AC DISCONNECT 2020 EXISTING BUILDING CODE OF NYS PV-2 ATTACHMENT DETAILS G 2020 FIRE CODE OF NYS PV-3 THREE LINE DIAGRAM 'F r. (N) 125A SOLAR LOAD CENTER Z n 2020 PLUMBING CODE OF NYS PV-4 PLACARDS&WARNING LABELS fn --1 2020 MECHANICAL CODE OF NYS PV-5 ADDITIONAL NOTES -4 PV-6+ SPEC SHEETS -7 DESIGN CRITERIA: 0 298 7 ROOF TYPE: -ASPHALT SHINGLE �FN O ERSION NUMBER OF LAYERS: - 1 DATE REV. F CONDITION: GOOD TION _ ROOF FRAME: -2"X8"RAFTERS @16"O.C. BLDG.PERMIT 11/05/2024 0 STORY: -TWO STORY SNOW LOAD : -25 PSF WIND SPEED :- 130 MPH WIND EXPOSURE:-D GENERAL NOTES: 1. INSTALLATION IN ACCORDANCE WITH MANUFACTURER /�RECOMMENDATIONS. ARRAY LOCATIONS 2. ENGINEER TO INSPECT PROJECT AFTER INSTALLATION AND CERTIFY COMPLIANCE. �-+ 3. PROJECT TO BE INSTALLED WITH CODE COMPLIANT PROJECT SITE RACKING INSTRUCTIONS FOR UNI-RAC SOLAR MOUNT SYSTEM. ARSHAMOMAQUE PROJECT NAME 4. FOLLOW BALLASTING SCHEDULE ON ROOF PLAN. ;a., 2SY. < Q 5. HARVEST POWER, LLC., THE SOLAR INSTALLATION ' CONTRACTOR, COMPLIES WITH ALL LICENSING&ALL Lighthouse Marine D _J RELATED REQUIREMENTS OF THE GOVERNING > QServices, Inc. — O MUNICIPALITIES AND THE LOCAL ELECTRIC UTILITY ' J J I— AHJ'S. � � 6. THIS PROJECT WILL COMPLY WITH THE CURRENT NEC > � � � �y _1 � w REQUIREMENTS INCLUDING ARTICLE 690 SOLAR t� ' Ltd e� Q z Q O Q >_ — Q7 07 PHOTOVOLTAIC PV SYSTEMS. r zs = C0 Z Z 0- LL 7. THE ROOF WILL HAVE NO MORE THAN A SINGLE LAYER Q � OF ROOF COVERING IN ADDITION TO THE SOLAR �� w W Z EQUIPMENT. _ sage e Q _ W ZZ 8. INSTALLATION WILL BE FLUSH-MOUNTED, PARALLEL 0, � � 190 Pheasant PI, �� z O d �, TO AND NO MORE THAN 6.5"ABOVE ROOF Greenport,NY 11944, P Q O Z 9. MAINTAIN A MINIMUM OF 18"CLEARANCE AT RIDGE lfitted � p W AND AT ONE GABLE EAVE. 4 • ! Brick Cove ° W 10. THIS DESIGN COMPLIES WITH 130 MPH WIND REQUIREMENTS OF THE RESIDENTIAL CODE OF N.Y.S i North fork Mar►.+t Ur Q AND ASCE 7-16. Adventures ls`a 11. WHEREVER THE ROOF PLAN DOES NOT COMPLY WITH Charters law ACCESS AND VENTILATION REQUIREMENTS OF THE SHEET NAME UNIFORM CODE, HARVEST POWER PROPOSES THAT COVER SHEET ALTERNATIVE VENTILATION METHODS WILL BE EMPLOYED. REVIEW AND APPROVAL SHALL BE AT THE a r # "* DISCRETION OF THE MUNICIPALITY IN WHICH THIS ' r SHEET SIZE DOCUMENT HAS BEEN FILED. ANSI B 12. THE DESIGN PLANS COMPLY WITH THE 2020 NEW YORK STATE UNIFORM FIRE PREVENTION AND 11" X 17" RESIDENTIAL BUILDING CODE. 1 AERIAL PHOTO 2 VICINITY MAP SHEET NUMBER PV-0 SCALE: NTS PV-0 SCALE: NTS PV_0 MODULE TYPE, DIMENSIONS,&.WEIGHT RooF AccEss AREA: ' NUMBER OF MODULES=50 MODULES SHALL BE LOCATED IN AREAS THAT DO NOT REQUIRE THE PLACEMENT OF GROUND MODULE TYPE=REC SOLAR REC460AA PURE-RX(460W)MODULES OVER OPENINGS SUCH AS WINDOWS OR DOORS,AND LOCATED AT STRONG POINTS OF MODULE WEIGHT=51.58 LBS/23.4 KG. BUILDING CONSTRUCTION IN LOCATIONS WHERE THE ACCESS POINT DOES NOT MODULE DIMENSIONS= 68.03"X 47.44"=22.41 SF CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS,WIRES OR SIGNS.: UNIT•WEIGHT OF ARRAY=2.30 PSF HARVESTPOWER VEST POWER LLC j SE HIGHWAY ISLIP NY 11752 AE 89-3585 ` �\ we�i st owernet * G ��A o ^�J SEE ENLARGE nj "VIEW ON PV-1.1 Y l// j •% �)\, . VERSION (. n_ [.L •�. ti':� DESCRIPTION DATE. REV. �,� Q`�I/S / •G "' �'( .� BLDG.PERMIT 11/05/2024 0 j �/L T/ti •�� '• �(c ' TWO-STORY /�` �l �` G+ / •�; ♦ ♦ �:;�• •• k' `\ HOUSE L-10 QUO �- • • • ';i • C�C� \ 9O �� • • �i iAl f�tk- , PROJECT NAME TO _l Q � QLuO (E)GATE �� r �,�' C� } (o (E) FENCE \ `� w �jJ Z 1 �r L.LI T r h �/1�y( � .r Q (E)TREE(TYP.) Q�. G SHEET NAME SITE PLAN WITH ROOF PLAN SHEET SIZE (E)DETACHED STRUCTURE �� � / ANSI B 11 To X 17" ,� SITE PLAN WITH ROOF PLAN SHEET NUMBER P\ -1 MODULE TYPE, DIMENSIONS & WEIGHT o���, ROOF ACCESS AREA: NUMBER OF MODULES=50 MODULES SHALL SHALL BE LOCATED IN AREAS THAT DO NOT REQUIRE THE PLACEMENT OF GROUND .' Q /MODULE TYPE=REC SOLAR REC460AA PURE-RX(460W)MODULES OVER OPENINGS SUCH AS WINDOWS OR DOORS,AND LOCATED AT STRONG POINTS OF P i MODULE WEIGHT=51.58 LBS/23.4 KG. ` BUILDING CONSTRUCTION IN LOCATIONS WHERE THE ACCESS POINT DOES NOT MODULE DIMENSIONS= 68.03"X 47.44"=22.41 SF - CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS,WIRES OR SIGNS. I p UNIT WEIGHT OF ARRAY=2.30 PSF ROOF#1 HARVESTPOWER REC460AA PURE-RX(460W) HARVEST POWER LLC V RAFTERS--2"X8"@16" O.0 941 SUNRISE HIGHWAY ISLIP 305°AZIMUTH,22°TILT �STEIR TERRACE,NY 11752 G L:(801)669-3585 ( Q� Q—vw�\GHA harvest ower.net I Z m � Z (50) ENPHASE IQ8X-80-M-US / J► o MICRO-INVERTERS ROOF#3 NEW __k460AA PURE-RX(460" .:' VERSION RAFTERS=2"X8"@16"O.0 DESCRIPTION DATE ' REV. ROOF#2 'i 125°AZIMUTH, 346 TILT BLDG.PERMIT nrosizoza o (1'1) REC460AA PURE-RX(460W) RAFTERS=2"X8"@16" O.0 / ♦� 305 AZIMUTH, 34 TILT �� /, / O ROOF#7 (03) REC460AA PURE-RX(460W) ':' RAFTERS=2"X8"@16" O.0 / ♦ ♦ PROJECT NAME 215.'AZIMUTH, 31°TILT ♦ ®, Q PGP� /Ea3 8T AC, f',=f4w ♦ Q } Z ♦ ROOF#4 Z O 0 Q H 03--REC460AA PURE-RX 460 Q 0 ® RAFTERS=2"X8"@16" O.0 (, O.Lu ♦ �� / ♦ 125 AZIMUTH, 11 TILT L _ (N)JUNCTION BOX �, '� ��,',., CD Q o ROOF.#6 ROO #5 SHEET NAME (02) REC460AA PURE-RX(460W) ��' �c°o�`��P `(05)REd460AA PURE-RX(460W) RAFTERS=2 X8 @16 O.0 ENLARGE VIEW 125°AZIMUTH, 31°TILT (N) 1"PVC CONDUIT P RAFTERS=2"X8"@16"O.0 RUN 7/8"ABOVE ROOF 125°AZIM.UTH;31°TILT �y ^ SHEET SIZE . (N) 125A SOLAR LOAD CENTER (E)200A MAIN SERVICE PANEL ANSI B WITH (E)200A MAIN BREAKER (N) 100A FUSED AC DISCONNECT- (INSIDE). 11 X 17" 1 ENLARGE VIEW (E) UTILITY METER (E) CHIMNEY SHEET NUMBER SCALE: 1/8"= V-0" PV-1 . v PV MODULES t HARVESTPOWER ARVEST POWER LLC /� RISE HIGHWAY ISLIP G,S E'T CE,NY 11752 V )989-3585 SEE ENLARGED VIEW O C \G '� b ' rvesf ower.net c ,` z m (E)ASPHALT SHINGLE ROOF �. `�> O029 1 � e GENERAL NOTES: VERSION 1. RAILS TO BE INSTALLED TWO PER PANELS AS SHOWN IN DETAIL. DESCRIPTION DATE ' REV. 2. ALL PENETRATIONS TO BE MADE@ 48"O.C. BLDG.PERMIT ivos/zoza o 3. BOLTS TOBE INSTALLED INTO RAFTERS. 4. MINIMUM 2.5"PENETRATION INTO WOOD FOR CODE COMPLIANCE. NOTE.- ATTACHMENT DETAIL "ACTUAL ROOF CONDITIONS AND RAFTERS(OR SEAM)LOCATIONS MAY SCALE: NTS VARY. INSTALL PER MANUFACTURER(S)INSTALLATION GUIDELINES AND ENGINEERED SPANS FOR ATTACHMENTS." END/ MID CLAMP PV MODULES PROJECT NAME Do - U) � J cy) Q � O 0, L-FOOT _I .Z Q LLI O = aZ � L` z t (E)ASPHALT SHINGLE ROOF J W h Z }- O 0 W = a ~ Z (N) UNIRAC Z a O Q ROOF/ DECK MEMBRANE Q CDa. O SM STANDARD RAIL 0 rn Z Lli (E) 2"X8" RAFTERS @ 16" O.0 O 2.5'.' MIN. EMBEDMENT - SHEET NAME ATTACHMENT FLASH KIT PRO FLASHING DETAIL SHEET SIZE BUILDING STRUCTURE ANSI-B 5/16" STAINLESS STEEL LAG BOLT 11" X 17" WITH SS EPDM BONDED WASHER, ATTACHMENT DETAIL (ENLARGE VIEW) 2-1/2" MIN. EMBEDMENT. SHEET NUMBER SCALE:NTS PV-2 (50) REC SOLAR REC460AA PURE-RX(460W) MODULES BILL OF MATERIALS (50) ENPHASE IQ8X-80-M-US MICRO-INVERTERS EQUIPMENT QTY DESCRIPTION SOLAR PV MODULE 50 REC SOLAR REC460AA PURE-RX(460W)MODULES (05) BRANCHES OF 10 MODULES CONNECTED IN PARALLEL PER BRANCH J INVERTER 50 ENPHASE IQ8X-80-M-US MICRO-INVERTERS LOAD CENTER 1 125A SOLAR LOAD CENTER SYSTEM SIZE:-50 x 46OW= 23.00 kWDC JUNCTION BOX 1 600V,55A MAX,4 INPUTS,MOUNTED ON ROOF FOR WIRE&CONDUIT TRANSITION HARVEST 50 x 380VA= 19.00 kWAC VEST POWER LLC AC DISCONNECT 1 AC DISCONNECT 100A FUSED,WITH 10OAl2P FUSES,240V NEMA 3R,UL LI I& E ISE HIGHWAY ISLIP —= E,NY 11752 *�G A�� L 989-3585 we s s: est owernet 10 MICRO-INVERTERS IN BRANCH CIRCUIT#1 Z m o NF y OFL� TO UTILITY GRID VERSION `�------- ----------- ----- ) — L1L2N--------1 DESCRIPTION DATE REV. 10 MICRO-INVERTERS IN BRANCH CIRCUIT#2 I BLDG.PERMIT 11/05/2024 0 BI-DIRECTIONAL I M UTILITY METER SUPPLY TAP WITH 1-PHASE,3-W, JUNCTION TAP BOX 120V/240V J ) i (N)125A SOLAR - ------ `-------------- `- ----------a LOAD CENTER 10 MICRO-INVERTERS IN BRANCH CIRCUIT#3 i JUNCCTIONTION6 I JU I M' IQ-GATEWAY TAP BOX I • I I _ (N)AC DISCONNECT 100A V V j j (N)JUNCTION BOX FUSED,VISIBLE LOCKABLE PROJECT NAME 15A LABELED,100A FUSES, �''------- �-- ---------- `- ----- -1 ' 240 VAC ai 10 MICRO-INVERTERS IN BRANCH CIRCUIT#4 i 1 u 2oA 100A 200A J I 20A FUSES Q 0 • • • i 1 L1 L1 L1 _ J � I 0 i (E)200A MAINE: I J 20A o SERVICE PANEL = = = i I u L N N W/(E)200A J Z Q LLI 0 ^Nv--I------- ~--'----------- ��--�'---------1 20A -------- --- ------ G ------ -- -------------� o (TOIP FBED)AKER = Z Z LL L1 '.L1 20A I I L¢ 0 I i i N LLJ = o' a- tz Z 10 MICRO-INVERTERS IN BRANCH CIRCUIT#5 i i i G z 0- C) Q _I • I u u i (3)#2 BLK RED THHN (2)#2 BLK RED THHN L-----------II] Q Z O I (1)#6 THHN STRANDED (1)#6 WHT THHN --i-- LLI GREEN GROUND IN 1 1/4" (1)#6 THHN STRANDED GROUNDING LLB N I PVC CONDUIT RUN GREEN GROUND IN 1 1/4" _ ------- 'V ELECTRODE SYSTEM�'--- V ) I G n I PVC CONDUIT RUN Ur Q -------- -------- r-------- ---- --=a-- ----- --- ----- N I I SHEET NAME (50)ENPHASE IQ8X-80-M-US (5)Q CABLE THREE LINE DIAGRAM MICROINVERTERS(240V) (1)#6 BARE CU GND (LOCATED UNDER EACH PANEL) (10) 10 AWG THWN-2 SHEET SIZE TERMINATOR CAP ON LAST CABLE (1)#6 THHN STRANDED ANSI B CONNECTOR Q-CABLE(TYP) GREEN GROUND IN 1"PVC CONDUIT 11" X 17" THREE LIN-E DIAGRAM SHEET NUMBER SCALE: NTS PV-3 4', rnHOCK RNL . AWARNINGELECTR HAZARD PHOTOVOLTAIC SYSTEM SOLAR PV SYSTEM EQUIPPED COMBINER PANEL TERMINALS ON LINE AND LOAD DO NOT ADD LOADS WITH RAPID SHUTDOWN HARVEST SIDES MAY BE ENERGIZED IN THE OPEN POSITION LABEL LOCATION: G� T ST POWER LLC PHOTOVOLTAIC AC COMBINER(IF �� HIG 117 ZISLIP APPLICABLE). � HAFT 89-3585 LABEL LOCATION: bsi st owernet INVERTER(S),AC DISCONNECT(S),AC 3 TURN RAPID SHUTDOWN COMBINER PANEL(IF APPLICABLE). co G SWITCH TO THE"OFF" 5OP pE ECTRIC ,�°` z m NELS POSITION TO SHUT DOWN '�A y PV SYSTEM AND REDUCE oa SHOCK HAZARD IN THE Q 9 1 ARRAY. NowYO VERSION FOR • ' ' PV SYSTEM DESCRIPTION DATE REV. } - LABEL LOCATION: BLDG.PERMIT 11/05/2024 0 ON OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE LABEL LOCATION: DISCONNECTING MEANS TO WHICH THE PV SYSTEMS UTILITY SERVICE ENTRANCE/METER, INVERTER/DC ARE CONNECTED. DISCONNECT IF REQUIRED BY LOCAL AHJ,OR OTHER LOCATIONS AS REQUIRED BY LOCAL AHJ. WARNING POWER SOURCE OUTPUT CONNECTION DO NOT RELOCATE THIS PROJECT NAME OVERCURRENT DEVICE LABEL LOCATION: < ADJACENT TO PV BREAKER AND ESS U) QCPD(IF APPLICABLE). BUILDING SUPPLIED BY UTILITY a GRID AND PHOTOVOLTAIC Z w o SYSTEM = W Z z a- LL WARNING: J Q - * } O • . • . LIJ = Of a- I— Z Z O Q J Q CD O LABEL LOCATION: Q W Z INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, AT EACH TURN,ABOVE AND BELOW PENETRATIONS, Q w ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. _ Q D_ A 0 PHOTOVOLTAIC AC DISC• rn SHEET NAME MAXIMUM . •. • AMPS ❑ (E)MAIN SERVICE PANEL PLACARD NOMINAL OPERATING (INSIDE) m (E)UTILITY METER WARNING LABELS LABEL LOCATION: (N)AC DISCONNECT SHEET SIZE ANSIB AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF (N)SOLAR LOAD CENTER INTERCONNECTION. 1 1„ X 17„ LABEL LOCATION: SHEET NUMBER POINT OF INTERCONNECTION (PER CODE:NEC690.56(B),NEC705.10,225.37,230.2(E)) PV-4 1. EACH MODULE TO BE GROUNDED USING THE SUPPLIED CONNECTION POINT PER MANUFACTURER'S REQUIREMENTS. ALL SOLAR MODULES, EQUIPMENT, AND METALLIC COMPONENTS ARE TO BE BONDED. IF.THE EXISTING GROUNDING TPOWER ELECTRODE SYSTEM CAN NOT BE VERIFIED OR IS ONLY METALLIC WATER PIPING, - WERLLC IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSTALL A SUPPLEMENTAL Q� ��y94 W7 zISLIP GROUNDING ELECTRODE. EL. 85 w wer.net 2. ALL PLAQUES AND SIGNAGE REQUIRED BY THE LATEST EDITION OF NATIONAL n ELECTRICAL CODE. LABEL SHALL BE METALLIC OR PLASTIC, ENGRAVED OR Cn 0 ~ MACHINE PRINTED IN A CONTRASTING COLOR-TO THE-PLAQUE. PLAQUE SHALL BE UVRESISTANT IF EXPOSED TO SUNLIGHT. YO�� 3. DC CONDUCTORS'SHALL BE RUN IN EMT AND SHALL BE LABELED, "CAUTION DC VERSION CIRCUIT" OR EQUIV. EVERY 5 FT. DESCRIPTION DATE.' REV. BLDG.PERMIT 11/05/2024 0 4. EXPOSED NON-CURRENT'CARRYING METAL PARTS OF ELECTRICAL EQUIPMENT SHALL BE GROUNDED IN ACCORDANCE WITH 250.134 OR 250.136(A). 5. CONFIRM LINE SIDE VOLTAGE AT ELECTRIC UTILITY SERVICE PRIOR TO CONNECTING INVERTER. VERIFY SERVICE VOLTAGE IS WITHIN INVERTER VOLTAGE OPERATIONAL RANGE. 6. OUTDOOR EQUIPMENT SHALL BE NEMA-3R RATED OR BETTER. PROJECT NAME 7. ELECTRICAL CONTRACTOR TO PROVIDE CONDUIT EXPANSION JOINTS AND < Q ANCHOR CONDUIT RUNS AS REQUIRED PER NEC. :D O 8. ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL - a- - MEANS DESIGNED AND LISTED.FOR SUCH USE AND FOR ROOF-MOUNTED O O � SYSTEMS, WIRING MUST BE:PERMANENTLY AND � z Q .w O COMPLETELY HELP OFF OF THE Q Q } — cn CO LL ROOF SURFACE. NEC 110.2 - 110.4 % 300.4 = Q Z ' 0 Z }: 9. ALL ROOF PENETRATIONS MUST BE FLASHED. SIMPLY CAULKING DOES NOT Z IL O Q � 3: SUFFICE. Q o. 0- I= O M w � F- w SHEET NAME ADDITIONAL NOTES SHEET SIZE ' ANSI B 11" X 17" SHEET NUMBER PV-5 RE[ ALPHA PLIRE-RX 5ERIE5 REC SOLAR'S MOST TRUSTED REC PROOLIET SPECIFICATIONS G T -- - -- u WER LLC N I WAY ISLIP vC,ENERALDATA cgs s ess �TER�P 1752 " --- _. (� 9- 585 Cell type: 88 half-cut REC bifacial,heterojunction cells ->� ---- --->.--------'- t - de: r t owernet with lead-free,gapless technology Glass: 3.2 mm solar glass with anti-reflective surface treatment ,amj Z 0 in accordance with EN 12150 y Backsheet: Highly resistant polymer j 1 noo na O� Frame: Anodized aluminum(black) I 91 O 17 REE ALPHA 4-part 4by cord diodes,lead-free Junction box: - - •j/ Y OR'( IP68 rated,In accordancewith IEC 62790 Staubli MC4 PV-KBT4/KST4(4 mm2) Connectors: in accordance with IEC 62852,IP68 only when connected PURE-RX Cable 4mm2solar rdancele,1.7 50618SERIES Inac05x3c mm(2N50619 VERSION Dimensions: 1728x1205x30 mm(2.08 rt% t r ° DESCRIPTION DATE REV. �_as ins PRODUCT SPECIFICATIONS Weight: 23.4kg r BLDG.PERMIT 11/OS/2024 0 Origin: Madein5ingapore , M ,urements m min ELECTRICAL DATA Product Code°:RECxxxAA Pure-RX CERTIFICATIONS Power Output-P.(Wp) 450 460 470 IEC61215:2021.IEC 61730:2016,UL61730 Watt Class Sorting-(W) 0/�10 0/.10 0/.10 IEC62804 PID IEC 61701 Salt Mist Nominal Power Voltage-V�(V) 54.3 54.9 55.4 IEC 62716 Ammonia Resistance Nominal Power Current-I.(A) 829 8.38 8.49 1S011925-2 Ignitability(EN 13501-1 Class E) 226 OpenC'ecuitVoltage-Va(V) 65.1 65.3 65.6 IEC62782 Dynamic Mechanical Load EC61215-22016 Hailstone(35mm) Short Circuit Current-Is,(A) 8,81 8.88 8.95 :EC62321 Lead-freeacc.toRoH5EU863/2015 Power Density(W/mo 216 221 226 IEC61730-2:2016 Fire Class C(as per LIL 790) Panel Efficiency(%) 21.6 22.1 22.6 ISO 14001.ISO 9001.IEC45001.IEC 62941 taka�wq Power Output-P.(Wp) 343 350 358 C♦ [ 'I •+•••rh�au• c..ar.R r.naro°d,.,. PROJECT NAME F Nominal Power Voltage-Vr,1e(V) 512 51.7 522 a s p rbe ace.,d..rc Nominal Power Current-I�,(A) 6.70 6.77 6.86 Declare. < 0 Z Open Circuit Voltage-V.(V) 61.3 61.6 61.8 W J Short Circuit Current-Isc(A) 7.11 7.17 7,23 TEMPERATURE RATINGS' 0 Values at standard test condtions(STC.air mass AM IS.irradiance 1000 W;m'temperature 2S*Q based on a production spread witha Nominal Module Operating Temperature: 44°C(t2°C) rJr•� tolerance afP Va&Ix 13%within one watt class.Nominal module operating temperature(NMDT:airmass LS,iradarxeBW ri/m'. Temperature coefficient ofP -024%/°C D I•-L J COMPACT .a PANEL temperature:Z° wirdspeedl rn/s)_'Where-indicates the nomirul pov,-er class at STC above Temperature hu.�e Temperature coefficient ofV.: -0.24%/°C O V MAXIMUM RATINGS'PMW" WARRANTY / Z Q W O Temperature coefficient of1.: 0.04%°C Operational temperature: -40._«85°C Standard REC ProTrust The temp erature coefficients s t a ted are linear values Q Q >_ \ W W S W � Maximum system voltage: 1000V Installed by an REC No Yes Yes _ ZZ �Certified Solar Profess"Maximum testload(front} «7000PaQ13kg/m2)' DELIVERY INFORMATION Q a . . System Size All c25kW 25 SOOkW W } rear: -4000Pa 407k m2' Panels perpalleC 33 Z Maximum test load (rear): ( g/ ) Product Warranty 20 25 25 N W Max series fuse rating: 25A Power Warranty(yrs) 25 25 25 Panels per40itGP/highcubecontainer: 594(18pallets) e - LL- -1 Z Panels per 13.6 m truck: 660(20 pallets) Labor rs 0 25 10 � Z O MaxreversecurrenC 25A Warranty ) Q a- 1- O 'See installation manual for mountin instructions Power in Year 98% 98% 98% woo Design load-Test load/LS(safety factor) ,,LOW LIGHT BEHAVIOUR Annual Degradation 025% 025% 0.25% EC Typical low irradiance performanceofmoduleatSiG �, LL.) # Power in Year 25 92% 92% 92% o � • The REC PreTrust Warranty is onlyy w available on panels purchased a ROT throw anREC Certified Solar Professionalinstaller.Warrant L.L , ►,�. 7' conditions apply,See www.recgroup.com for more details c ¢ rrl < •T r -� ELIGIBLE Available from: - Invdaw(W/W) SHEET NAME _ -. SPEC SHEET rOr SHEET SIZE - ---- ANSI B y+ '� RECSdarPTE.LTO. s - � .�.�.. - ? Founded in 1996.REC Group is an international pioneering solar energy company dedicated to empowering consumers 20Tuas South.LM. it n - •• _..} _ _ - with clean,affordable solar power.As Solar's Most Trusted.REC is committed to high quality,innovation,and a low R C C 11 X 17 ask, ,,. �� PEP as a carbon footprint in the solar materials and solar panels it manufactures.Headquartered in Norway with operational post@orgroup.2 y* f .].� '.- headquarters in Singapore,REC also has regional hubs inNorthAmerica,Europe.andAsia-Pacific. post@recgroup.com www.recgroup.com SHEET NUMBER SOLARMOUNT so ::• UNIRA 1 1 1 1 1 1• 1 1 1. 1 BETTER DESIGNS TRUST THE INDUSTRY'S BEST DESIGN TOOL CONCEALED UNIVERSAL 0 1 ' 1 1 , 1 � � , 1 1 •, , , 1 Slam the design process tar every project in our U builder air line design tool ENDCLAMPS 0 It s a great way to save time and money. �. 1 1 1 1 1 1 1 1 BETTER SYSTEMS _ ONE SYSTEM-MANY APPLICATIONS �!! -- Quickly get modules[lush to the roof on steep pitched roofs.Orient a large variety ®® ,, „�•�->-- of modules in Portrait or Landscape.Tilt the system up on flat or law slow roofs. END CAPS INCLUDED CompaQ htsavailableininill.cleat anddark(inishnstooptimizeyourdesignfinancials WITH EVERY ENDCLAMP and aeskhatics. --� BETTER RESULTS MAXIMIZE PROFITABILITY ON EVERY JOB CONCEALED Trust Unirac to help you minimize both system and labor costs tram the time the job is UNIVERSAL quoted to the time your teamsget off the roof.Faster installs.Less Waste.More Profits. CLAMPS UNIVERSAL SELF d°UNIRAC BETTER SUPPORT STANDING MIDCLAMPS 25 WORK WITH THE INDUSTRIES MOST EXPERIENCED TEAM Professional support for professional installers and designers.You have access to -- -- YE our technical support and training groups.Whatever your support needs,weve got • 1 I '1 OPTIONAL you covernd.Visit Unirac.com/sM,urnunnl foi more information. < . . r FRONT TRIM ftllL YSiEa1 L • WAflflANiY U-BUILDER ONLINE DESIGN • i• 1 TOOL SAVES TIME&MONEY BONDING&GROUNDING _ Visit design.unoac cam go o UL2703MESCTHEAMNIFWECLA SIFTSYflRCCLASSIFICATIDN . Lu • • r < • UNIRAC CUSTOMER SERVICE MEANS THE HIGHEST LEVEL OF PRODUCT SUPPORT • . ❑ , . 1 '• I I ( 1 I I UNMATCHED CERTIFIED ENGINEERING BANKABLE DESIGN PERMIT Lii 1 r EXPERIENCE QUALITY EXCELLENCE WARRANTY TOOLS DOCUMENTATION • � . 1 TECHNICAL SUPPORT CERTIFIED QUALITY PROVIDER BANKABLE WARRANTY Unuac's t 4:hnical support team Is dedicated to answering Umrac is the only PV mounting vendor with ISO Doll leave your project to chance.Unirac has the questionstaddressmg issues in real time.Anonline certifications fur 9001:2008,14001-2004 and OHSAS financial strength to back our products arld reduce your risk. SHEET NAME 7 library at documents mcludingengmecnngreports, 18001:2007.which meanswe deliver ihehwheststandards Have peace ofmmdknowmg you are providmgproducts at THE PROFESSIONALS CHOICE FOR RESIDENTIAL RACKING stamped letters and technical data sheets greatly for fit.form.and function.These certifications demonstrate exceptional quality.SOLARMOUNT is covered by a 25 year SPEC SHEET simplifies your permitting and project planning process. out excellence and commitment tohrst class business practices. limited product warranty and a 5 year limited finish warranty. SHEET SIZE BEST INSTALLATION EXPERIENCE*CURBAPPEAL•COMPLETE SOLUTION•UNIRACSUPPORT ENHANCE YOUR REPUTATION WITH QUALITY RACKING SOLUTIONS BACKED BY ENGINEERING EXCELLENCE AND A SUPERIOR SUPPLY CHAIN ANSI B FOR QUESTIONS 0R CUSTOMER SERVICE VISIT LINIRAC.00M 0R CALL (505) 248-2702 FOR QUESTIONS OR CUSTOMER SERVICE VISIT UNIRAC.COM OR CALL (505) 248 2702 A- A- 0 Unirac state Letter-NY STPOWER Tectonic Tecto' nicl Tectonic WO#;12557.24 �G OWERLLC ...x..........r.o.,.,...,... August 12,2024 Q, - v,.nueso.onaxs...ronox,as.mu. • l�� � HWAY ISLIP ,c - \•l�- R 11752 8 8 585 } August 12,2024 Metal Roof:Standing Seam Attachments, PM-9000s,and. PM Adjust Slotted e:wi .ls3ouver net co Unirac Tile Roof:Solar hooks, Flashkit Tile Replacement(TR) Dz M. Attn: Engineering Services Department _ The U B.uilder Tool should be.used under .the responsible charge:of a registered ON. O �r 1411 Broadway,Boulevard NE professional engineer required by the authority having jurisdiction: The design tool G�`'98 Albuquerque,'NM 87102-1545 and Unirac do not evaluate the existing roof structure,or the PV panels themselves. TEL:(505)242-6411 See the construction and Installation drawings_ and manuals for additional �� YOB information provided by Unirac. RE: ENGINEERING CERTIFICATION LETTER FOR THE,UNIRAC SOLARMOUNT (SM) ROOF PV PANEL SUPPORT SYSTEM Sincerely, of NEP. VERSION STATE.NEW YORK '(� Y DESCRIPTION DATE ' REV. TECTONIC WORK ORDER:#:12557.25 TeCtO171C Qo��o A. U'�R`O9� BLDG.PERMIT 11/05/2024 0 The Unirac SOLARMOUNT(SM).Photov_oltaic Panel,Support System is a.proprietary Q p Cc framed photovoltaic panel support system that .is installed on a roof. Tectonic m r z Engineering Consultants, .Geologists & Land. Surveyors, D.P.C. (Tectonic). has reviewed the SM design methodology along with the U-Builder tool;a Unirac online �,0 471249 design tool. The review included the following SM products,SM Light, Heavy Duty, stoNo 08/12/2024 and Standard rail with both the standard.and pro hardware. Antonio A. Gualtieri. P.E. Tectonic-has determined,that the design is a rational, approach and follows the Executive Vice President structural re uirements of the following reference documents. Codes/Standards: • 2020 Building Code:of New York State. . PROJECT NAME • 2018 International.Building Code by International Code Council. Q ASCF/SEI 7-16 Minimum Design Loads for Buildings and Other Structures,.by U) ❑ American Society of'Civil Engineers with provisions from SEAOC PV-2--2017. J • .2020 Aluminum Design Manual, by Aluminum Association. < _j This letter certifies that the structural analysis'of the:racking members,connections, "T o H '� (D and components directly related to Unirac's system are in compliance'with the J Z above codes. The design methodology is acceptable u Q LLJ nder components and Q �, < 0) 0 cladding loads associated with the building's roof structure when the .system .is = (A Z Z 0 installed in accordance with manufacturer.specifications.If the Loading criteria does. not meet Unirac's specifications, owner shall contact Unirac for a site-specific LU = W 0- ~ Z certification. Q J Q CD a O Attachments approved for the SM system.to the structure include the following Q W =. H and is-installed per Unirac's U-Builder report and installation guides: LLj 2 Shingle Roof- L-Foot Flashkit Pro, Standoffs, Flashloc Comp, Flash Loc Duo, ( : Q and Flash Kit Pro SB SHEET NAME Project Contact Info Project Contact Info 1279 Route 300 I Newburgh,NY 12550 1279 Route 200 1 Newburgh,NYa 2550 SPEC SHEET 845.561.6656 Tel 1 845.567.8703 Fax 845.567,6656 Tel 1 845.567..8703 Fax SHEET SIZE tectohicengineerirlg.com tectonicengineering.com page 2 of 2 ANSI S.l p v Equal Opportunity Employer Equal'Opportunity AN Employer 11" X 17" SHEET NUMBER PV-8