Loading...
HomeMy WebLinkAbout51661-Z Of SOUlyo`o Town of Southold # * P.O. Box 1179 �0 53095 Main Rd O��OOUPI Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 46041 Date: 03/14/2025 THIS CERTIFIES that the building AS BUILT GENERATOR Location of Property: 2285 Westview Dr Mattituck,NY 11952 Sec/Block/Lot: 107.-7-1.1 Conforms substantially to the Application for Building Permit heretofore, filed in this office dated: 01/07/2025 Pursuant to which Building Permit No. 51661 and dated: 02/19/2025 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: "as built" accessory generator as applied for. The certificate is issued to: Jared Lettieri,Leah Lettieri Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: 51661 03/07/2025 PLUMBERS CERTIFICATION: `�AVN �Wlt-1 Aut o iz d Signature ho��oFSQ�,yo(o TOWN OF SOUTHOLD BUILDING DEPARTMENT • TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 51661 Date: 02/19/2025 Permission is hereby granted to: Jared Lettieri 2285 Westview Dr Mattituck,,NY 11952 To: legalize "as built"generator as applied for. Premises Located at: 2285 Westview Dr, Mattituck, NY 11952 SCTM# 107.-7-1.1 Pursuant to application dated 01/07/2025 and approved by the Building Inspector. To expire on 02/19/2027. Contractors: Required Inspections: Fees: As Built Generator $250.00 ELECTRIC -Residential $200.00 CO-RESIDENTIAL $100.00 Total S550.00 'Iding Inspector OE SObTHo� # # TOWN OF .SOUTHOLD BUILDING DEPT. �ycouto, 631-765-1802 C,6� � INSPECTION [ ] FOUNDATION 1 ST [ XRROGH PLBG. FOUNDATION 2ND [ LATIOWCAULKING FRAMING /STRAPPING [ L O [ ] FIREPLACE &-CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: 1 v cr6k4wit - vv- DATE INSPECTOR SOUlyO6 N T OF SOUTHOLD BUILDING DEPT. coum, 631-765-1802 INSPECTION [ ] FOUNDATION 1 ST/REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ]. INSULATION/CAULKING [ ] FRAMING/STRAPPING [ ] FINAL [ ] FIREPLACE-& CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION X PRE C/O [ ] RENTAL 1 REMARKS: V(Ze f 0 r\ Mdf,4f/- DATE INSPECTOR �pF SO!/T�, �o� ono Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 • OQ Southold,NY 11971-0959 0 �yCOW TY,� ' BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION i Issued To: Jared Lettieri Address: 2285 Westview Dr City: Mattituck St: NY Zip: 11952 Building Permit#: 51661 section: 107 Block: 7 Lot: 1.1 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: Esco Electric License No: 43646ME SITE DETAILS Office Use Only Indoor rl Basement (- Service Solar 1— Outdoor f�� 1 st Floor r—i Pool F Spa F Renovation I_ 2nd Floor 17- Hot Tub Generator (✓; Survey Attic nF Garage Battery Storage I INVENTORY Service 1 ph [ Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph 1- Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch 150A UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures Other Equipment: 18kW Generator w/ 150A Transfer Switch Supplying Only One Panel Notes: " AS BUILT NO VISUAL DEFECTS " Generator I Inspector Signature: X Date: March 7, 2025 Sean Devlin Electrical Ilnspector sean.deviinAtown.southold.ny.us 2285WestviewGenerator • � ` 1� � t Il. _ t. .. , Ar-V- s + h AV ADANGER APELIGRO 7� �k -MIS y ; �..i'.� +` ,..-• Asa 41'�rc FIELD INSPECTION REPORT DATE COMMENTS _ hn FOUNDATION (1ST) - - ----- -------- ------------------------------------- C FOUNDATION (2ND) z _ o rr nn H ROUGH FRAMING& ---- V ' PLUMBING _ •3 - Co r INSULATION PER N.Y. -- - - STATE ENERGY CODE - FINAL - -- ADDITIONAL COMMENTS x —-- _ - �► Cyx�7 — — x Y , I ff0(� o BUILDING DEPARTMENT-Electrical Inspector TOWN OF SOUTHOLD o Town Hall Annex- 54375 Main Road - PO Box 1179 • Southold, New York 11971-0959 16� Telephone (631) 765-1802- FAX (631) 765-9502 amesh@southoldtownny.00v--seand@southoldtownnv.aov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 12/11/24 Company Name: Esco Electric LLC Electrician's Name: Esad Bojadzic License No.: 43646ME Elec. email:esco@esco-electric.com Elec. Phone No: (631)728-3830 ❑I request an email copy of Certificate of Compliance Elec. Address.. 15 Wakefield Road, Hampton Bays, NY 11946 JOB SITE INFORMATION (All Information Required) Name: Jared Lettieri Address: 2285 Westview Drive, Mattituck, NY 11952 Cross Street: Grand Avenue Phone No.: (631)574-7450 Bldg.Permit 51(0(01 email:Jared@lettiericonstruction.com Tax Map District: 1000 Section:107.00 Block: 07.00 Lot:001.001 ESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): « 3tf V, Sa of -Square Footage: 12800 Circle All That Apply: 1Vt s P I z 23 Is job ready for inspection?: YES[—]NO I✓ Rough In Final Do you need a Temp Certificate?: ❑ YES Q NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A #Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground Clove rhead #Underground Laterals 0 1 H Frame Pole Work done on Service? Y MN. Additional Information: PAYMENT DUE WITH APPLICATION is2 2 25 ala��r lay �S( w i+h puff if f �6 o � g s_ ��� 5- /14 PERMIT# Address: Switches Outlets GFI's Surface Sconces H H's UC Lts Fridge HW POOL Fans Mini Fr. W/D Panel Pump Exhaust Oven Sump Heater Trnsfmr Smokes DW Generator Salt Gen. Carbon Micro GrbDis Water Bond Lights Heat Pucks ERV HOT TUB/SPA Inst Hot DeHum Transfer Disc Combo Cooktop Minisplit Blower AC AH Hood Blower Service Amps Have Used Sub Amps Have Used Comments o��SOFFOIMCOG TOWN OF SOUTHOLD—BUILDING DEPARTMENT N Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 oy�01 �ao� Telephone(631) 765-1802 Fax (631) 765-9502 hops://www.southoldtoyLmy.gov Date Received APPLICATION FOR BUILDING PERMIT " p E Chi EOME For Office Use Only PERMIT NO. Building Inspector: JAN 7 2025 Applications and forms must be filled`out in their entirety.lncomplete" Building Department applications will not be accepted.-Where the Applicant is not the owner,.an Town of Southold Owner's Authorization form(Page 2)shall'be completed. _ Date: - l Z O 1-(1 OWNER(S)OF-PROPERTY; r Name: J�Ced�L��- SCTM#1000- 1-0-7, 00- o-7 , 00.- po'. 00( Project Address: 5--y%f_w ,ve, Phone#: Email: `` 5_0 JrL�ec @_Lr— e-ri COA5 VC, �0n. Cam••, Mailing Address: a�_ W c>4Q•'A n_ 13tr.c (1 `i? CONTACT PERSON. Name: Mailing Address: Phone#: ` tr I y S'O Email: DESIGN PROFESSIONAL INFORMATION: Name: Mailing Address: Phone#: Email: CONTRACTOR INFORMATION: Name: Mailing Address: Phone#: Email: DESCRIPTION OF PROPOSED'CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair []Demolition Estimated Cost of Project: Other T,,Ai a cc l��` 3 er4 $ 11006. Will the lot be re-graded? ❑Yes & o Will excess fill be removed from premises? ❑Yes Piro- 1 PROPERTY INFORMATION' Existing use of property: S . l idcn Intended use of property: Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to ti T this property? ❑Yes KNo IF YES, PROVIDE'A COPY. -® Check Box After,Reading: The owner/contractor/design professional is responsible#orall drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone. ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or-demolition as herein described.The applicent,agreesto comply with altapplicable laws,ordinances;building code, housing code and regulations'and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are .punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print name): J 0.rtx,� ❑Authorized Agent ®Owner Signature of Applicant: ^^ —T _ Date: 1 , -T ( Z A STATE OF.NEW YORK) SS: COUNTY OF 51'�C�1C` ) Jrej L,-z kV, being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the 0`J A Gr (Contractor,Agent,Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this /� day of , 20 U 5 Nota .Manna Nobry Pubk-State of New y, 04 NO.01MA4899066 Qualified In Suffolk coumyd PROPERTY OWNER AUTHORIZATION ConmisalmExpimsos-2o• (Where the applicant is not the owner) I, residing at do hereby authorize to apply on my behalf to the Town of Southold Building Department for approval as described herein. Owner's Signature Date Print Owner's Name 2 SURVEY OFPROPERTY .�Piz S,��No 5�� SITUATE MATTITUCK TOWN OF SOUTHOLD I S UFFOLK COUNTY, N. Y. SURVEYED: JUN. 6 2024 00 10 . o o 000019001 0I 2285 WESTVIEW DR, MATTITUCK, NY, 1195�? �`�• o�N° LOT AREA 22346. 28 S. F. s (0. 513 ACRE(S)) I CERTIFIED TO: Na Advantage Title Title# 24—as-60976 Jared Lettieri and Leah Lettieri 1st Priority Mortgage, inc., its successors and/ or assigns, o �°• '? �' '�. as their interests may appear �• oNCO*", 'CIS '�J tih '�•�2Q¢ �� �� 1q'•1CIO, � � Q OF NEW EL K. O 1' Fti •o. - Gj� GAP 3 4m <01 F �°• 0503gG yob 4 � o LAND S STANDARD NOTES: co 1. COPYRIGHT 2024 MICHAEL K. WICKS LAND SURVEYING COPIES OF THIS SURVEY MAP NOT DFARING 2. UNAUTHORIZED ALTERATION OR ADDITION TO THIS SURVEY MAP BEARING A OR EMBOSSED SEAL SHALL NOT BECONSICi'^ .' =D rC:) .� LICENSED LAND SURVEYOR'S SEAL IS A VIOLATION OF SECTION 7209, C I SUB--DIVISION 2, OF NEW YORK STATE EDUCATION LAW. MICHAEL K. WICKS, P.L. S. #50390 I 3. ONLY BOUNDARY SURVEY MAPS WITH THE SURVEYOR'S EMBOSSED SEAL ARE GENUINE TRUE AND CORRECT COPIES OF THE SURVEYOR'S ORIGINAL WELL WORK AND OPINION. P O + MICHAEL WicKs 4. CERTIFICATIONS ON THIS BOUNDARY SURVEY MAP SIGNIFY THAT THE MAP WAS PREPARED IN ACCORDANCE WITH T BY THE HE CURRENT EXISTING CODE OF MO PRACTICE F PROFESSIONAL A LAND EDSURVEYORS,E INC.YORK STATE HE CERTIFICATION IS 0. �D•ASSOCIATION O /� LAND S UR V E YI NC LIMITED TO PERSONS FOR WHOM THE BOUNDARY SURVEY MAP IS PREPARED, S71 0 12 40 85.37 � Tj TO THE TITLE COMPANY, TO THE GOVERNMENTAL AGENCY, AND TO THE LENDING INSTITUTION LISTED ON THIS BOUNDARY SURVEY MAP. 15 FROWEIN RD — SUITE E2 5. THE CERTIFICATIONS HEREIN ARE NOT TRANSFERABLE. CENTER MORICHES, NEW YORK 11934 6. THE LOCATION OF UNDERGROUND IMPROVEMENTS OR ENCROACHMENTS ARE WESTVIEWNOT ALWAYS KNOWN AND OFTEN MUST BE ESTIMATED. IF ANY UNDERGROUND DR VOICE: 631.874.0155 IMPROVEMENTS OR ENCROACHMENTS EXIST OR ARE SHOWN, THE www.www.wickslandsurveying.com IMPROVEMENTS OR ENCROACHMENTS ARE NOT COVERED BY THIS SURVEY. RECORDS OF RICHARD C. DRAKE 7. THE OFFSET (OR DIMENSIONS) SHOWN HEREON FROM THE STRUCTURES TO i THE PROPERTY LINES ARE FOR A SPECIFIC PURPOSE AND USE AND THEREFORE SCALE: SURVEYED BY: DRAWN BY: SHEET: ARE NOT INTENDED TO GUIDE THE ERECTION OF FENCES, RETAINING WALLS, POOLS, PATIOS PLANTING AREAS, ADDITIONS TO BUILDINGS, AND ANY OTHER » > a TYPE: OF CONSTRUCTION. 1 —30 M.W. J.W.W. 1 OF 1 F k a E 3 II f i i, { p APPR VED AS NOTE DATE- J B.P.# FEE BY fit d NOTIFY BUILDING DEPARTMEWTAT OCCUPANCY OR 631.765-1802 8AMT04PM FOR THE ��E IS UNLAWFUL INSPECTIONS: 1. FOUNDATION-TWO REQUIRED WITHOUT CERTIFICA� FOR POURED CONCRETE 2. ROUGH-FRAMING&PLUM,,41,13fn!G ®F OCCUPANCY 3. INSULATION 4. FINAL-CONSTRUCTION MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTON ERRORS COMPLY WITH ALL-CODES OF ELECTRICAL NEW YORK STATE&TOWN CODES INSPECTION REQUIRED AS REQUIRED AND CONDITIONS OF SO LDTOWN ZBA SO OLD TOWN PLANNING BOARD SO OLD TOWN TRUSTEES N .S,DEC UTHOLD HPC SCHD KOHLER. Models: 14RCA(L) Multi-Fuel LPG/Natural Gas 09001 standard Features III KOHLER. . RDC2 Controller NATIONALLY REGISTERED o One digital controller manages both the generator set and .•--�- transfer switch functions (with optional Model RXT)., o Electronic speed control responds quickly to varying • demand. o OnCue(D Plus Generator Management System for remote monitoring is included with the generator. • Kohler Command PRO Engine Features o Kohler Command PRO@ OHV engine with hydraulic valve lifters for reliable performance without routine valve adjustment or lengthy break-in requirements. Is Designed for Easy Installation o Sturdy aluminum base can be mounted on gravel or a concrete mounting pad. o Fuel and.electrical connections through the enclosure wall The Kohler® Advantage eliminate the need for stub-ups through the base. o Customer connection terminal block located near the • High Quality Power controller allows easy access for field wiring. Kohler home generators provide advanced voltage and o Designed for outdoor installation only. frequency regulation along with ultra-low levels of • Certifications harmonic distortion for excellent generator power quality to protect your valuable electronics. o Meets emission regulations for U.S. Environmental Protection Agency(EPA) with both natural gas and LPG. • Extraordinary Reliability o UL 2200/cUL listed (60 Hz model). Kohler is known for extraordinary reliability and o CSA certification available (60 Hz model). performance and backs that up with a premium 5-year or o Accepted by the Massachusetts Board of Registration of 2000 hour limited warranty. Plumbers and Gas Fitters. • Powerful Performance o Meets 181 mph wind rating. Exclusive Powerboost� technology provides excellent 14RCAL models packaged with a Model RXT automatic starting power. The Kohler 14 kW generator can easily p g start and run a 5 ton air conditioner. transfer switch are available. See page 4 and the Model RXT ATS specification sheet. • Aluminum Enclosure Warranty o Attractive aluminum enclosure allows installation as t o• War year/2000 hour limited warranty for on grid (standby) close as 18 inches from your home or small business. applications in locations served by a reliable utility source. o Enclosure panels can be removed without tools to allow o 18 month/1000 hour limited warranty for off-grid easy access for maintenance and service. (non-standby) applications. Generator Ratings Standby Ratings Non-Standby Ratings Line Circuit Natural Gas LPG Natural Gas LPG Breaker kW/ kW/ kW/ Alt. Voltage Phases Hz kVA Amps kW/kVA Amps kVA Amps kVA Amps Amps Poles 2F5 - 120/240 1 60 12/12 50 14/14 58 12/12 50 14/14 58 70 2 120/208 3 60 12/15 41 13/16 45 12/15 41 13/16 45 50 3 2G5 120/240 3 60 12/15 36 13/16 39 12/15 36 13/16 39 50 3 277/480 3 60 12/15 18 13/16 20 12/15 18 13/16 20 25 3 Note: The line circuit breaker is automatically selected based on the generator set model and voltage configuration. RATINGS:Standby ratings apply to Installations served by a reliable utility source.All single-phase units are rated at 1.0 powerfactor.The standby rating Is applicable to variable loads with an average load factor of 80%for the duration of the power outage. No overload capacity is specified at this rating. Ratings are In accordance with ISO-304611,BS5514,AS2789,and DIN 6271.GENERAL GUIDELINES FOR DERATING:ALTITUDE:Derate 4%per 305 m(1000 ft.)elevation above 153 m(500 ft.).TEMPERATURE:Derate 2%per 5.51 C(10'F)temperature Increase above 16°C(60°F). Availability is subject to change without notice.The generator set manufacturer reserves the right to change the design or specifications without notice and without any obligation or liability whatsoever. Contact your local Kohler Co.generator distributor for availability. § Check the appliance manufacturer's specifications for actual power requirements.Consult a Kohlers Power Systems professional to.calculate your exact residential power system requirements. t Meets NFPA guidelines for 18 inch clearance to combustible materials. Check state and local codes for minimum distance required from a structure. G4-270 (14RCA) 5/21d Alternator Specifications Alternator Specifications Alternator Features Specifications Alternator • Compliance with NEMA, IEEE, and ANSI standards for Manufacturer Kohler temperature rise. Type 2-Pole,Rotating Field . Self-ventilated and dripproof construction. Leads,quantity 2F5 4 • Windings are vacuum-impregnated with epoxy varnish for 2G5 12 dependability and long life. Voltage regulator Digital • Superior voltage waveform and minimum harmonic Insulation: NEMA MG1-1.66 distortion from skewed alternator construction. Material Class H • Digital voltage regulator with±1.0% no-load to full-load Temperature rise 130°C Standby RMS regulation. Bearing:quantity,type 1,Sealed • Rotating-field alternator with static exciter for excellent Coupling Direct load response. Amortisseur windings Full . Total harmonic distortion (THD)from no load to full load with Voltage regulation,no-load to full-load RMS ±1.0% a linear load is less than 5%. One-step load acceptance 100%of Rating Peak motor starting kVA: (35%dip for voltages below) 240V, 1 ph 2F5(4 lead) 33(60 Hz) 240 or 480 V,3 ph 2G5(12 lead) 54(60 Hz) Application Data Engine Exhaust Engine Specifications Exhaust System Manufacturer Kohler Exhaust temperature exiting the Engine:model,type CH740 4-Cycle enclosure at rated kW,dry, °C(°F) 260(500) Cylinder arrangement V-2 Lubrication Displacement,cm3(cu.in.) 725(44) Bore and stroke,mm(in.) 83 x 67(3.27 x 2.64) Lubricating System Compression ratio 9;1' Type Full Pressure Main bearings:quantity,type 2,PTO Side-Load Sleeve Oil capacity(with filter),L(qt.) 1.8(1.9) Bearings Oil filter:quantity,type§ 1,Cartridge Rated RPM Oil cooler Integral 60 Hz 3600 § Kohler recommends the use of Kohler Genuine oil and filters. Max.engine power at rated rpm,kW(HP) LPG,60 Hz 17.6(23.6) Fuel Pipe Size Natural gas,60 Hz 15.3(20.5) Cylinder head material Aluminum Minimum Gas Pipe Size Recommendation,in.NPT Valve material Steel/Stellite@ Natural Gas LPG Pipe Length,m(ft.) 193,000 Btu/hr. 203,000 Btu/hr. Piston type and material Aluminum Alloy Crankshaft material Heat Treated,Ductile Iron 8 (25) 3/4 3/4 Governor:type Electronic 15 (50) 1 3/4 Frequency regulation,no load to full load Isochronous 30 (100) 1 1 Frequency regulation,steady state tO.5% 46 (150) 1 1/4 1 Air cleaner type Dry 61 (200) 1 1/4 1 Engine Electrical Engine Electrical System Ignition system Electronic, Capacitive Discharge Starter motor rated voltage(DC) 12 Battery(purchased separately): Ground Negative Volts(DC) 12 Battery quantity 1 Recommended cold cranking amps: (CCA) rating for-18°C(0°F) 500 Group size 51 G4-270 (14RCA) 5/21d Fuel Requirements RDC2 Controller Features, Continued Fuel System • LED indicators for utility power and generator set source Fuel types Natural Gas or LPG availability and ATS position (Model RXT transfer switch Fuel supply inlet 1/2 NPT required) Fuel supply pressure,kPa(in.H20): • LCD display: Natural gas 1.2-2.7(5-11) o Two lines x 16 characters per line LP 1.7-2.7(7-11) o Backlit display with adjustable contrast for excellent Fuel Composition Limits* Nat.Gas LPG visibility in all lighting conditions •Methane,%by volume(minimum) 90 min. — Scrolling system status display: o Generator set Status o Voltage and frequency Ethane,%by volume(maximum) 4.0 max. — Propane,%by volume 1.0 max. 85 min. o Engine temperature Propene,%by volume(maximum) 0.1 max. 5.0 max. o Oil pressure C4 and higher,%by volume 0.3 max. 2.5 max. o Battery voltage Sulfur,ppm mass(maximum) 25 max. o Engine runtime hours Lower heating value, MJ/m3(Btu/ft ), (minimum) 33.2(890) 84.2(2260) • Date and time displays * Contact your local distributor for suitability and rating derates based • Smart engine cooldown senses engine temperature on fuel compositions outside these limits. • Digital isochronous governor maintains steady-state speed at all loads Operation Requirements • Digital voltage regulation: ±1.0% RMS no-load to full-load Fuel Consumption,m3/hr.(cfh)@ 60Hz • Automatic start with programmed cranking cycle %Load Natural Gas LPG • Programmable exerciser can be set to start automatically on 100 5.4 (193) 2.3 (81) any future day and time,and run every week or every two 75 4.7 (163) 2.1 (75) weeks 50 3.5 (124) 1.8 (60) • Exercise modes: 25 2.6 (93) 1.2 (45) o Unloaded weekly exercise with complete system Exercise 1.7 (60) 0.8 (30) diagnostics Nominal fuel rating: Natural gas: 37 MJ/m3(1000 Btu/ft.3) o Unloaded full-speed exercise LPG: 93 MJ/m3(2500 Btu/ft.3) o Loaded full-speed exercise (Model RXT ATS required) LPG conversion factors: 8.58 ft 3=1 lb. • Front-access mini USB connector for SiteTech- or USB 0.535 m3=1 kg Utility connection 36.39 ft3 =1 gal. • Integral Ethernet connector for Kohler@ OnCue@ Plus Generator Set Sound Data • Built-in 2.5 amp battery charger - • Remote two-wire start/stop capability for optional connection Model 14RCA 8 point logarithmic average sound levels are of a Model RDT transfer switch 63 dB(A) during weekly engine exercise and 69 dB(A) during • Diagnostic messages: Displays diagnostic messages for the full-speed generator diagnostics and normal operation.* engine,generator, Model RXT transfer switch, programmable All sound levels are measured at 7 meters with no load. interface module (PIM),and load management device. * Lowest of 8 points measured around the generator. Sound levels at • Maintenance reminders other points around generator may vary depending on installation • System settings: parameters. o System voltage,frequency, and phase RDC2 Controller o Voltage adjustment o Measurement system, English or metric • ATS status (Model RXT ATS required): o Source availability Freg9 6 e 24OV 0 o ATS position (normal/utility or emergency/generator) ao Source voltage and frequency 0 0 • ATS control (Model RXT ATS required): © � o Source voltage and frequency settings ® OFF AM AM o Engine start time delay —� o Transfer time delays o Voltage calibration The RDC2 controller provides integrated control for the o Fixed pickup and dropout settings generator set, Kohler@ Model RXT transfer switch, • Programmable Interface Module(PIM)status displays: programmable interface module (PIM),and load shed kit. o Input status (active/inactive) RDC2 Controller Features o Output status (active/inactive) • Load control menus: • Membrane keypad: o Load status o OFF,AUTO, and RUN pushbuttons o Test function o Select and arrow buttons for access to system configuration and adjustment menus • LED indicators for OFF,AUTO,and RUN modes G4-270 (14RCA) 5/21d KOHL K�HLER® Phone 9 CO.,Kohler,Wisconsin 9-164 USA Phone 920-457-4441,Fax 920-459-1646 For the nearest sales and service outlet in the US and Canada,phone 1-800-544-2444 KOHLERPower.com Generator Set Standard Features Automatic Transfer Switches and Accessories • Battery cables - ❑ Model RDT ATS • EPA certified fuel system ❑ Model RXT ATS • Aluminum sound enclosure ❑ Model RXT ATS with combined interface/load management board • Critical silencer L] Load shed kit for RXT or RDT • Field-connection terminal block ❑ Power relay modules (use up to 4 relay modules for • Fuel solenoid valve and secondary regulator each load management device) • Line circuit breaker ❑ Other Kohler@)ATS • Multi-fuel system, LPG/natural gas,field-convertible 14RCAL Model Packages • Oil drain extension with shutoff valve ❑ 14RCAL with 100 amp RXT with 16-space load center and • OnCues Plus Generator Management System NEMA 1 steel enclosure for indoor installation • Premium 5-year/2000 hour limited standby warranty ❑ 14RCAL with 200 amp service entrance-rated Model RXT, • 18-month/1000 hour limited warranty for non-standby with combined interface/load management board and (off-grid) applications corrosion-resistant NEMA3R aluminum enclosure • RDC2 generator set/ATS controller Warranty • Rodent-resistant construction ❑ 5-Year Comprehensive Limited Warranty • Sound-deadening,flame-retardant foam per UL 94, ❑ 10-Year Comprehensive Limited Warranty class HF-1 Available Options Approvals and Listings ❑ CSA approval Concrete Mounting Pads ❑ Concrete mounting pad,3 in.thick ❑ Concrete mounting pad,4 in.thick (recommended for storm-prone areas) Electrical Accessories ❑ Battery ❑ Battery heater, 120VAC Generator Set Dimensions and Weights ❑ Battery heater,240VAC Cold weather package, 120VAC Generator Set Size,L x W x H: 1193 x 6.2 x 2.2 mm ❑ p g (47 x 26.2 x 32.2 in.) ❑ Cold weather package,240VAC ❑ Emergency stop kit Shipping Weight: 14RCA Generator Set 200 kg(440 lb.) ❑ PowerSync@ Automatic Paralleling Module (APM) 14RCAL with 100 A RXT ATS w/LC: 227 kg(500 lbs.) (single phase only;parallel two 14kW residential generator 14RCAL with 200 A RXT SE ATS 222 kg(490 lb.) sets with the RDC2 controller) r L ❑ Programmable interface module (PIM) (provides 2 digital inputs and 6 relay outputs) Fuel System Accessories ❑ Flexible fuel line(included on QS models) HMEMO ❑ Carburetor heater, 120 VAC ❑ Carburetor heater,240 VAC Carburetor heater is recommended for reliable starting at temperatures below 0°C (32°F) I F110:_ U W Literature ❑ NOTE:Dimensions are provided for reference only and should not be used for planning General maintenance literature kit installation.Contact your local distributor for more detailed Information. ❑ Overhaul literature kit DISTRIBUTED BY- ❑ Production literature kit Maintenance ❑ Maintenance kit(includes air filter,oil, oil filter,and spark plugs) ©2018 Kohler Co.All rights reserved. G4-270 (14RCA) 5/21d