Loading...
HomeMy WebLinkAbout48911-Z �o��OF SOUlyo6 Town of Southold * * P.O. Box 1179 0 53095 Main Rd uNr ' Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 46037 Date: 03/14/2025 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 3200 Camp Mineola Rd Mattituck, NY 11952 Sec/Block/Lot: 123.-5-36.2 Conforms substantially to the Application for Building Permit heretofore,filed in this office dated: 01/31/2023 Pursuant to which Building Permit No. 48911 and dated: 02/15/2023 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: Roof-mounted solar panels to existing single-family dwelling as applied for. The certificate is issued to: Matthew Perry , Jill Perry Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: 48911 3/11/2025 PLUMBERS CERTIFICATION: (AuUrized Si ature �SUFFo�,t�o TOWN OF SOUTHOLD boo. oy. BUILDING DEPARTMENT cm z. TOWN CLERK'S OFFICE ca "o • SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 48911 Date: 2/15/2023 Permission is hereby granted to: Perry, Matthew 360 E 72nd,St Apt 131701 New York; NY 1'0021 To: install roof-mounted solar panels to existing single-family dwelling as applied for. At premises located at: 3200 Camp Mineola Rd, Mattituck SCTM #473889 Sec/Block/Lot# 123.-5-36.2 Pursuant to application dated 1/31/2023' and approved by the Building Inspector. To expire on 811612024. Fees: SOLAR PANELS $50.00 ELECTRIC $100.00 CO-ALTERATION TO DWELLING $50.00 Total: $200.00 Bui ng nspector oE so�ryol Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 CAR • Q Southold,NY 11971-0959 'O BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Matthew Perry Address: 3200 Camp Mineola Rd City: Mattituck St: NY Zip: 11952 Building Permit* 48911 section: 123 Block: 5 Lot: 36.2 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: Element Energy License No: 52689ME SITE DETAILS Office Use Only Indoor 14—Vi Basement F- Service 1- Solar rv—� Outdoor I✓' 1 st Floor F- Pool F: Spa F. Renovation F— 2nd Floor r— Hot Tub 1- Generator (- Survey (✓ Attic rr I Garage Battery Storage r INVENTORY Service 1 ph 1- Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures Other Equipment: 10.4kW Roof Mounted PV Solar Energy System w/ (26)QcellQpeakDuoBLK ML-G10+400W PV Modules, Combiner Panel w/ (2)220Breakers, 40A Fused Disco, Lineside Notes: Solar Inspector Signature: X Date: March 11, 2025 Sean Dev m Electrical Inspector sea n.devlin0-town.south old.ny.us 3200CampMineolaSolar OE SOUTyo� TOWN OF SOUTHOLD BUILDING DEPT. `ycourm, 631-765-1802 INSPECTION [ ] FOUNDATION 1 ST [ ] ROUGH PL13G. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING/STRAPPING [ ki/FINAL So//a-fe- [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: 01&h2,t C /eel . DATE //—/(v —a3 INSPECTOR oy��OFSOUIyp� �� �1 h 1 # # TOWN OF SOUTHOLD BUILDING DEPT. co 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [Xj ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: J y tar hn Prness DATE 90 A3 INSPECTOR OF SOUTyO6 ,*� ( TOWN OF SOUTHOLD BUILDING DEPT. 631-765-1802 INSPECTION [ ] FOUNDATION 1ST/.REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ -] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [" } FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) >4D ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ]. RENTAL REMARKS: G. Li DATE INSPECTOR j 32C0 C�rnp �'�E�e6lo, C� MaR 1 � z025 1�a-�fi�u C� l lWDOOFM STD AC SOIJ R ME ELECl r S1'$IEAI ACTED it A�Ir i 1 j ? i j 1 WARNING t � 1ELD INSPECTION REPORT j DATE COMMENTS FOUNDATION (1ST) y ------------------------------------ aD FOUNDATION (2ND) W z 0 a y ROUGH FRAMING& y PLUMBING cb 0 1 r r� INSULATION PER N.Y. STATE ENERGY CODE FINAL ADDITIONAL COMMENTS �V - a` C ' ko o - � p Z rn � k . ►d 4� y %J O y4 y x d r� • b Zoho Sign Document ID:2A768FFA-3WJUJUNOKVUZWVCUWB_EIJYRB3(UTFU-XVNRYNST7ZUXY gOFFOt& TOWN OF SOUTHOLD —BUILDING DEPARTMENT �o s� y Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 �y�,o• �oo� Telephone (631) 765-1802 Fax(631) 765-9502 https://www.southoldtownn oovv Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only PERMIT NO. Building Inspector: NV- JAN1 I, Applications and forms must be filled out in their entirety.Incomplete - applications will not be accepted. Where the Applicant is not the owner,an BUILDINGDEPT Owner's Authorization form(Page 2)shall be completed. TOWN OFSOMMOLD Dater OWNER(S)OF PROPERTY: Name: Mathew Perry SCTM# 1000- 1000-123.00-05.00-036.200 Project Address: 3200 Camp Mineola Road, Mattituck, NY 11952 Phone#: 631-786-4892 Email: Mailing Address: CONTACT PERSON: Name: Charles Jacabacci Mailing Address: 7470 Sound Ave., Mattituck, NY 11952 Phone#: 631-388-7041 Email: charles.jacabacci@e2sys.com DESIGN PROFESSIONAL INFORMATION: Name: Mailing Address: Phone#: Email: CONTRACTOR INFORMATION: Name: Element Energy LLC Mailing Address: 7470 Sound Ave., Mattituck, NY 11952 Phone#: 631-779-7993 Email: permits@e2sys.com DESCRIPTION OF'PROPOSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair El Demolition Estimated Cost of Project: ✓Other 10.4 $ 36,688.00 Will the lot be re-graded? Dyes ✓No Will excess fill be removed from premises? Dyes ✓ No 1 �J PROPERTY INFORMATION Existing use of property: Residential Intended use of property: Residential Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to Residential Zone AC this property? ❑Yes ✓No IF YES, PROVIDE A COPY. I✓Check Box After Reading: The owner/contractor/design professional is responsible for ail drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION 15 HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable.Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print name): Charles Jacabacci ✓Authorized Agent ❑Owner Signature of Applicant: Date: Jan 27 2023 STATE OF NEW YORK) SS: COUNTY OF Suffolk ) Charles Jacabacci being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)h.e-is the Contractor/Agent (Contractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make.and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this day of ( r0h 20 0- Notary Public DEBRA A SEPULVEDA PROPERTY OWNER AUTHORIZATI N NorARYpLTB>al„srerBOFNEWYORC (Where the applicant is not the owner RegistradonNa01SEM12M Qualified in Suffoi Coon My Commission Expires 6? d v2 I, Mathew Perry residing at 7470 Sound Ave.,Mattituck, NY 11952 do hereby authorize Element Energy LLC to apply on my behalf to the Town of Southold Building Department for approval as described herein. Jan 27 2023 Owner's Signature Date MATHEW PERRY Print Owner's Name 2 Zoho Sign Document ID:2A768FFA-3WJUJUNOKVUZWVUWB_EIJYRB3UTFU-XVNRYNST7ZUXY ri. � SUfFQ��. BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD I C= z Town Hall Annex- 54375 Main Road - PO Box 1179 o� ® ! }; Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 roQerrCaDsoutholdtownsy_..gov--seand(aD-southoldtownny.gov. APPLICATION FOR ELECTRICAL INSPECTION' ELECTRICIAN INFORMATION (All Information Required) Date: Jan 27 2023 Company Name: Element Energy LLC Name: Jamie Minnick License No.: 52689-ME email: permits@e2sys.com Address: 7470 Sound Ave.,Mattituck,NY 11952 Phone No.: 631-861-5920 JOB SITE INFORMATION (All Information Required) Name: Mathew Perry Address: %vc Cross Street: Phone No.: 631-786-4892 Bldg.Permit#: email:/yf�-A ,2 1,,, 70 0/1- (tAw. Tax Map District: 1000 Section 1 23.00 Block: 05,00 LO : 036.200 BRIEF DESCRIPTION OF WORK(Please Print Clearly) .Roof mounted solar PV-system.consisting,of_(26)Enphase.IQ8PLUS-72-2-US Micro_Inverters_(26)Solar PV panels QCELL.QPEAK .. DUO BLK ML-G10+400 Circle All That Apply: Is job ready for inspection?: ✓ •/ NO Rough In Final Do you need a Temp Certificate?: NO Issued On Temp. Information: (All information required) Service Size 1 Ph 3 Ph Size: A #Meters Old Meter# New Service - Fire Reconnect- Flood Reconnect- Service Reconnected- Underground -Overhead # Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT-DUE WITH_APPLICATION Request for Inspection Form.xls ACoRo® CERTIFICATE OF LIABILITY INSURANCE DATE(MM7/2�/20R2 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT NAME: ROBERT S.FEDE INSURANCE AGENCY PHONE - - FAX - - 23 GREEN STREET,SUITE 102 E-MAIL t Arc No HUNTINGTON, NY 11743 ADDRESS: ROBERTS.FEDE INSURANCE INSURER(S)AFFORDING COVERAGE NAIC# INSURERA:ATLANTIC CASUALTY INS.CO. 524210 INSURED INSURERB:STATE INSURANCE FUND 523930 Element Energy LLC INSURERC:SHELTER POINT POINT 81434 ELEMENT'ENERGY SYSTEMS INSURERD:GENERAL STAR MANAGEMENT CO. 7470 SOUND AVENUE INSURER E MATTITUCK, NY 11952 INSURER F COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSRPOLICY EXP LTR TYPE OF INSURANCE IN WVQ ADSD SUBR POLICY NUMBER MM/DD POLICY YEFF MMIDD/YYYY LIMITS COMMERCIAL GENERAL LIABILITY CL00275204 EACH OCCURRENCE $ 3,000,000 A X X 7/14/2022 7/14/2023 CLAIMS-MADE � OCCUR DAMAGES(TO RENTED PREMISES Eacccurrence) $ 100,000 #D IMA389203A MED EXP(Any one person) $ 5000 X Contractual Lia 7/14/2022 7/14/2023 PERSONAL&ADV INJURY $ 3000000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ 3,000,000 POLICY KI PRO- JECT 7 LOC PRODUCTS-COMP/OP AGG $ 3000000 OTHER: $ AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $ Ea accident ANY AUTO BODILY INJURY(Per person) $ OWNED SCHEDULED AUTOS ONLY AUTOS BODILY INJURY(Per accident) $ HIRED NON-OWNED PROPERTY DAMAGE $ AUTOS ONLY AUTOS ONLY Peraccident UMBRELLA LIAB OCCUR EACH OCCURRENCE $ EXCESS LIAB CLAIMS-MADE AGGREGATE $ DED I RETENTION$ $ WORKERS COMPENSATION 124494445 TT—PER OTH- AND EMPLOYERS'LIABILITY Y/N 7/13/2022 7/13/2023 STATUTE ER ANY PROPRIETOR/PARTNER/EXECUTIVE E.L.EACH ACCIDENT $ 1,000,000 B OFFICERIMEMBER EXCLUDED? FX I N/A (Mandatory in NH) E.L.DISEASE-EA EMPLOYE $ 1000,000 if yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ NY State DBL DBL5s7527 1/01/2022 1/01/2023 Statutory DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,maybe attached If more space is required) CERTIFICATE HOLDER IS ADDITIONAL INSURED CERTIFICATE HOLDER CANCELLATION TOWN OF SOUTHOLD SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 54375 MAIN ROAD THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. SOUTHOLD, NY 11971 AUTHORIZED REPRESENTATIVE ROBERTS FEVE ©1988-2015 ACORD CORPORATION. All rights reserved. ACORD 25(2016/03) The ACORD name and logo are registered marks of ACORD AFNII�N NYSI F New York State Insurance Fund PO Box 66699,Albany,NY 12206 1 nysif.com CERTIFICATE OF WORKERS' COMPENSATION INSURANCE 0 .0 A A A A A 823336604 ROBERT S FEDE INSURANCE AGENCY 23 GREEN ST STE 102 0 HUNTINGTON NY 11743 SCAN TO VALIDATE AND SUBSCRIBE POLICYHOLDER CERTIFICATE HOLDER ELEMENT ENERGY LLC TOWN OF SOUTHOLD DBA ELEMENT ENERGY SYSTEMS 54375 MAIN ROAD 7470 SOUND AVENUE SOUTHOLD NY 11971 MATTITUCK NY 11952 POLICY NUMBER CERTIFICATE NUMBER POLICY PERIOD DATE 12449 444-5 95991 07/13/2022 TO 07/13/2023 7/19/2022 THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE FUND UNDER POLICY NO. 2449 444-5, COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS' COMPENSATION LAW WITH RESPECT TO ALL OPERATIONS IN THE STATE OF NEW YORK, EXCEPT AS INDICATED BELOW, AND, WITH RESPECT TO OPERATIONS OUTSIDE OF NEW YORK, TO THE POLICYHOLDER'S REGULAR NEW YORK STATE EMPLOYEES ONLY. IF YOU WISH TO RECEIVE NOTIFICATIONS REGARDING SAID POLICY,INCLUDING ANY NOTIFICATION OF CANCELLATIONS, OR TO VALIDATE THIS CERTIFICATE,VISIT OUR WEBSITE AT HTTPS://WWW.NYSIF.COM/CERT/CERTVAL.ASP.THE NEW YORK STATE INSURANCE FUND IS NOT LIABLE IN THE EVENT OF FAILURE TO GIVE SUCH NOTIFICATIONS. THIS POLICY DOES NOT COVER THE SOLE PROPRIETOR, PARTNERS AND/OR MEMBERS OF A LIMITED LIABILITY COMPANY. THE POLICY INCLUDES A WAIVER OF SUBROGATION ENDORSEMENT UNDER WHICH NYSIF AGREES TO WAIVE ITS RIGHT OF SUBROGATION TO BRING AN ACTION AGAINST THE CERTIFICATE HOLDER TO RECOVER AMOUNTS WE PAID IN WORKERS'COMPENSATION AND/OR MEDICAL BENEFITS TO OR ON .BEHALF OF AN EMPLOYEE OF OUR INSURED IN THE EVENT THAT, PRIOR TO THE DATE OF THE ACCIDENT, THE CERTIFICATE HOLDER HAS ENTERED INTO A WRITTEN CONTRACT WITH OUR INSURED THAT REQUIRES THAT SUCH RIGHT OF SUBROGATION BE WAIVED. THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE COVERAGE UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICY. NEW YORK STATE SUR NCE FUND 4 DIRECTOR,INSURANCE FUND UNDERWRITING VALIDATION NUMBER: 126776733 Zoho Sign Document ID:2A768FFA-K50YY6UPUWXAXRRVHBPJDYUTL8(3FHUTWHDJ9L6A(:BUU Town of Southold O /y January 24th, 2023 Building Department (� Town Hall Annex 54375 Main Road P.O. Box 1179 Southold, New York 11971-0959 Subject: Roof Mounted Solar Panels at the Perry Residence, 3200 Camp Mineola Rd, Mattituck, NY 11952 To Town of Southold: I hereby state that it is my professional opinion that the subject plans comply with the 2020 Residential Code of New York State, the 2017 National Electric Code,ASCE 7-16, and NFPA-70. These code requirements include the fact that the roof framing is adequate to support the additional loads from solar panels as well as roof ridge and peak access to first responders. I have evaluated the structural framing of the existing roof with the additional loading to account for the proposed solar panel application. Deflection and stresses of the structural components remain within the allowable for the existing roof for wind pressures from 140 mph, 3-second gust, and Exposure B with a ground snow load of 20 pounds per square foot. Mounting locations and methods are as indicated in the submitted plans. From the site inspection and analysis, and as evidenced by previous roof loads withstood, it is my professional opinion that the existing building and roof framing is structurally adequate to support the reactions of the solar panels in addition to the existing code required for live and dead loads.Also, the wind analysis concluded that the mounting system as shown on the plans is adequate to resist the calculated uplift pressure. The dead load of the heaviest solar panel assembly in this evaluation is approximately 2.7 pounds per square foot. Please contact me if you have any questions or comments about the above. Sincerely, Gennaro Anthony Giustra. P.E. 141E Great Eastern Services, Inc. 0 �,��'�O PO Box 240 24 Harvey Rd Riverhead, NY 11901 Office: 631.543.9555 Mobile: 631.235.0189 � Email: jerrygiustra@gmail.com ?oho Sign Document ID:2A768FFA-K5UYY6CPUWXAXRRVHBPJDYQTL8GFHCTWHDJ9L6ACBUQ F K DE51GN t DRAFTING BY: SCOPE I, WORK 25 ELEMENT ENERGY LLC -0 INSTALL A 10.4 KW SOLAR PHOTOVOLTAIC(PV)SYSTEM AT THE PERRY RESIDENCE, REVIEW BY J.M.NABC2P CER7IFIE -OCATED AT 3200 CAMP MINEOIA RD, MATTITUCK, NY 1 1952 ;a os 1 I I z-129 -HE POWER GENERATED BY THE PV SYSTEM WILL BE INTERCONNECTED WITH THE UTILITY GRID Cutchogue -HROUGH THE EXISTING ELECTRICAL SERVICE EQUIPMENT. REVISIONS �i 26 DE5CRIPTION DATE REV 3YST E M RATING OR GINAL O I-09-2023 DA kW DC STC hAattituck ew SU S,un6 Pie QUIPMENT SUMMARY ?G QCELL Q.PEAK DUO BLK ML-G 10+ 400 WATT PV MODULES ?G ENPHASE IQ8PLU5-72-2-U5 MICRO INVERTERS CONTRACTOR IRONRIDGE XR 100 MOUNTING SYSTEM 5 h EET INDEX Laurel Roofs ELEMENT ENERGY, LLC. 'V-1 COVER PROJECT LOCATION 7470 SOUND AVE 'V-2 SITE PLAN MATTITUCK, NY 1 1 95 'V-3 ROOF PV LAYOUT 'V-4 STRUCTURAL/DETAILS 4 SECTIONS LICENSE # G74G I-H I 'V-5 3-LINE ELECTRICAL DIAGRAM ,, �5 NEPp LICENSE # 52G89-ME IV-G LABELS ,� O A Gj }. GOVERNING CODES ` o Fir � >01 7 NATIONAL ELECTRICAL CODE. I 1020 RESIDENTIAL CODE OF NEW YORK STATE. PROJECT NAME ?020 FIRE CODE OF NEW YORK STATE. \SCE 7-1 G AND NFPA-70. t(y 461,^� �T W 270°0 0 90° E # Q )5HAJNDE 2 CF CffRS LABORATORIES (UL)STANDARDS _tom, 240° V 120° a N OSHA 9 R 1910.2G9 ��` � 3ENERAL NOTES 210180150 z O CONTRACTOR SHALL CHECK AND VERIFY ALL CONDITIONS AT S tL1 ILJ HE SITE PRIOR TO STARTING TO WORK AND SHALL FAMILIARIZE C) z IMSELF WITH THE INTENT OF THESE PLANS AND MAKE WORK z GREE THE SAME. AERIAL VIEW LU . CONTRACTOR OR OWNER SHALL OBTAIN ALL REQUIRED PPROVAL5, PERMITS, CERTIFICATES OF OCCUPANCY, 10. CONTRACTOR TO EFFECT AND MAINTAIN INSURANCE, I.E. TOWN COMMENTS AND APPRC de6iTi,�l�p-�ALLCODES of 15PECTION APPROVALS, ETC., FOR WORK PERFORMED FROM � Q CONTRACTOR'S LIABILITY, WORKMAN-5 COMPENSATION, ----- - � GENCIES HAVING JURISDICTION THEREOF, IF REQUIRED. COMPLETED OPERATION, ETC. ADEQUATE FOR THE PURPOSES 8c TG'Whl CrJD>w a/ U ALL WORK SHALL CONFORM TO CONSTRUCTION CODE AND , O OF THIS PROJECT AND FURNISH PROOF OF SAME PRIOR TO ,s A�+ AS REQUIRED AND CC^�J(T'O�S Cs'�= it W .LL RULES AND REGULATIONS OF THE RESPONSIBLE COMMENCING WITH WORK. AP R VED AS NOTIED C U Jf IN TTION. I I . EACH SUBCONTRACTOR SHALL BE RESPONSIBLE FOR I , ',' . IF IN THE COURSE OF CONSTRUCTION A CONDITION EXISTS N MAINTAINING SAFETY ON THE JOB SITE DURING THE DATE: B.P.N m /HICH DISAGREES WITH THAT AS INDICATED ON THESE PLANS, CONSTRUCTION PHASE TO COMPLY WITH THE REGULATIONS SC J,OY N PLAN011IG BODAR: HE CONTRACTOR SHALL STOP WORK AND NOTIFY THE 1116 AND REQUIREMENTS OF THE OCCUPATIONAL SAFETY AND FEE: BY: _ NGINEER. SHOULD HE FAIL TO FOLLOW THIS PROCEDURE AND HEALTH ADMINISTRATION. THIS SHALL INCLUDE, BUT APE NOT NOTIFY'BUILDING DEPARTMENT AT E5PN WITH THE WORK, HE SHALL ASSUME ALL — G iOHJP�TPL'ST�tS LIMITED TO: PROVIDING FO ADEQUATE AND PROPER BRACING, SPON5IBILITY AND LIABILITY THEREFROM R 765-1802 8 AM TO 4 PM FOR THE SAFETY RAILINGS AND SECURE FOOTINGS FOR ALL TEMPORARY OCCUPANCY OR ALL STRUCTURAL STEEL SHALL BE A-3G AND SHALL BE FOLLOWING INSPECTIONS: ABRICATED AND INSTALLED AS PER LATEST A.L.S.0 SCAFFOLDING, STAIRS, ETC.. AS WELL AS PERMANENT ;. FOUNDATION - TWO REQUIRED PECIFICATIONS. CONSTRUCTION. �`O� /�p . ALL ELECTRICAL WORK SHALL BE BOARD OF FIRE 12. FIGURED DIMENSIONS SHALL GOVERN. DO NOT SCALE FOR POURED CONCRETE USE IS UNLAWFUL 1. V I\ NALL ELECTRICAL APPROVED AND B ACCORDANCE WITH N.E.C. DRAWINGS, WHERE DIMENSIONS ARE ESTABLISHED BY EXISTING 2. ROUGH - FRAMING & PLUMBING CONDITIONS. EACH CONTRACTOR SHALL VERIFY EXISTING 3. INSULATION WITHOUT CERTIFICAT. YS CODES 4 REGULATIONS CONDITIONS PRIOR TO ORDERING MATERIALS AND ANY DEVIATION FROM THESE PLANS WITHOUT THE WRITTEN COMMENCING WITH WORK. 14. FINAL - CONSTRUCTION MUST DPawiil,5C4LE ONSENT OF THE ENGINEER WILL NEGATE THE ENGINEER'S 13. CONTRACTOR TO REMOVE ALL DEBRIS CREATED BY THIS BE COMPLETE FUn C.Q. )F OCCUPANCY ERTIFICATION OF THESE PLANS. WORK FROM THE SITE AND DISPOSE OF IN A LEGAL MANNER ON ALL CQNSTRUCTiON SHALL MEET THE ^ I THESE DRAWINGS AS IN5TRUCMENT5 OF SERVICE ARE AND A WEEKLY BASIS OR SOONER IF CONDITIONS WARRANT. REQUIREMENTS OF THE CODES OF NEW 1 v 'T'5 HALL REMAIN THE PROPERTY OF THE ENGINEER WHETHER THE 14. AT THE COMPLETION OF WORK, THE SITE TO BE CLEARED ROJECT FOR WHICH THEY ARE MADE 15 EXECUTED OR NOT. YORK STATE. NOT RESPONSIBLE FOR ELECTRICAL HEY ARE NOT TO B LE E USED ON ANY OTHER PROJECTS OR OF ALL DEBRIS AND EXCESS MATERIALS. THE FACILITY IS TO BE DESIGN OR CONSTRUCTION ERRORS. )(TENSIONS TO THIS PROJECT LEFT BROOM CLEAN AND WORK IS TO BE COMPLETED TO THE INSPECTION REQUIRED TOTAL SATISFACTION OF THE OWNER PRIOR TO RELEASE OF 5HeL7 IIUNIBER . CONTRACTOR SHALL PROTECT, PATCH AND REPAIR ALL FINAL PAYMENT. p I S CO 11 n'eG� rn�CS'� X15TING WORK ADJACENT TO HIS WORK, OR DAMAGED AS 4 , PV- I ---IJtT OF HIS WORK. oC 0 1, / TAX MAP: 1 000- 1 23.00-05.00-03G.200 Zoho Sign Document ID:2A768FFA-K50YY6GPUWXAXRRVHBPJDYUTL8GFHGTWHDJ9L6AGBUU LEGEND DESIGN E DR/�FTING BY: EXISTING UTWJTY METER ELEMENT ENERGY LLC MAIN SERVICE PANEL / REVIEW BY 1 M.N2-129 CEPTIFIE NEW PV SUB—PANELS 00 A/C DISCONNECT COMBINER INVERTERS '% GND ELECTRODE '/ 4 REVISIONS PV MODULE /' W270 Q DESCRIPTION DATE REV L go-E ORIGINAL 01-09-2023 RACKING RAIL 240 0 0 ATTACHMENT POINT / 21po D 120° ---RAFTERS 1800 150 FROOF PITCH ANGLE cess R r SUNRUN METER VENT PLUMBING VENT a riser SKY LIGHT CONTRACTOR CHIMNEY COMPOSITE SHINGLES GOOD CONDITION POTENTIAL SHADING ISSUES TRIM/REMOVE AS NECESSARY ELEMENT ENERGY, LLC. 7470 SOUND AVE 17-2" MATTITUCK, NY 1 195 LICENSE # G74G 1-111 —, LICENSE # 52G89-ME PROJECT r1AME 4" N W C.L/ U w Q - 81 %`�- AGCL55 ROOr C) O U-j z I FI 5ETBACK DGE .1 A f g 131-10jL R/ O 1 T-7" I T-7" LLJ N m Q I I'-72' ❑ O ccrss Roor /ACCESS ROOr SHELT IIAME O5 NE* �- SITE PLAN NOTE # 1 .)THE ROOF 5ETBACWATHWAY SHALL NOT BE oRAwluc SCALE REQUIRED TO ROOFS WHEN OPPOSING OR n A& ADJACENT ROOF 15 ACCESS ROOF IN e — ■e. a- �/ 7J II _ I I oil ACCORDANCE WITH R324.G. I EXCEPTION OF F T0144"3 2020 NY5 RESIDENTIAL CODE. 0 � �—a4�y�, CONSTRUCTION NOTES 4J�" T NUMBERE ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE / % SHEE / MANUFACTURER'5 INSTALLATION INSTRUCTIONS. PV-2 2.) ALL OUTDOOR EQUIPMENT SHALL BE RAINTIGHT WITH MINIMUM NEMA 3R RATING. 3.) ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. TAX MAP: 1 000- 1 23.00-05.00-03G.200 Zoho Sign Document ID:2A768FFA-K50YY6CPUWXAXRRVHBPJDYOTL8GFHCTWHDJ9L6AUBUU •fir DE51GN&DRAFTING BY: ELEMENT ENERGY LLC REVIEW BY J.M.NABCEP CERTIFIE 051112-129 0° REVISIONS DE5CRIPTI0N DATE REV W270 Q 90° ORIGINAL OI-09-2023 E 240° Dv 210° 120° ACCE55 ROOF 180°1500 S 721 Rip6g CONTRACTOR ELEMENT ENERGY, LLC. 7470 SOUND AVE DT" MATTITUCK, NY 1 195 LICENSE # G74G I-HI LICENSE # 52G(59-ME 2" El PROJECT NAME ARRAY#6 2G riTcm N 254°AZIMUTH Lu U � � z O - LLJ W \y ACCESS ROOF/ ACCESS ROOF C) / 164°A2IMUTFI 1 B'FI 5MACKQRIDGE B'FIRE SETBACK RIDGE L/L 9211 U / 164'I A21 CONSTRUCTION NOTES Y LES O Q LEGEND 1.) ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE 254'AZ",`-" WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. F 1 CCE.55 ROOF 7�EASnNG UTILITY METER 2.)ALL OUTDOOR EQUIPMENT SHALL BE RAINTIGHT WITH MAIN SERVICE PANEL MINIMUM NEMA 3R RATING. /ACCESS ROOF NEW PV SUB-PANELS A/C DISCONNECT 3.) ALL LOCATIONS ARE APPROXIMATE AND REQUIRE . M� RS COMBINER FIELD VERIFICATION. y SHEET NAME IN CCE55 ROOF; ELECn20DE fiiii �f� `�/�/� ` !C► �/ G ACCESS ROOF . PV MODULE NOTE . " * *I .)THE ROOF SETBACK/PATHWAY SHALL NOT BE ROOF DETAI � —RACKING RAIL REQUIRED TO ROOFS WHEN OPPOSING OR o ATTACHMENT POINT ADJACENT ROOF IS ACCESS ROOF IN ACCORDANCE WITH R324.G. I EXCEPTION OF -*--ROOF Rs PITCH ANGLE 4 ---R 2020 NY5 RESIDENTIAL CODE. 254°AaMDTn 70344.3 DRAWING 5CALE 'r °�JTM �j SUNRUN METER CONSTRUCTION SUMMARY 3/32" = 1 I-OII VENT _ PLUMBING VENT (2G QCELL Q.PEAK DUO BILK ML-G 10+ 400 WATT PV MODULES I SKY LIGHT (DIMENSIONS: X 4 1 . I'I X I.3") (2G) ENPHASE IQSPLU5US-72-2-US MICRO INVERTERS snEET NUMBER CHIMNEY (54)ATTACHMENT POINTS @ G4'I O.C. MAX. "" COMPOSITE SHINGLES (150.3) LF IRONRIDGE XR100 MOUNTING SYSTEM. PV_3 CO TIAL ITIONSHAD SHAD ROOF TYPE: ASPHALT SHINGLE (SINGLE LAYER) TAX MAP: 1000- 123.00-05.00-036.200 POTENTIAL SHADING ISSUES TRIM/REMOVE AS NECESSARY Soho Sin Document ID:2A768FFA-K50YY6CPUWXAXRRVHBPJDYUTL8GFHCTWHDJ9L6ACBU(� ING BY: -OAD CALCULAJTION ARRAY5#1-5 ARRAY#G ARRAY#7 ITEM DESCRIPTION ARRAYS #I - 7 EDE51GN ERTGY LLC RD Rid e Bearn/BOard 2"X 12" D. FIR Roof Rafters 2"X 10" D. FIR I G" O.0 ABCEP CERTIFIEVIODULE WEIGHT(Lbs) 48.4 48.4 46.4 (D) Deckin 5/8" PLYWOOD 05 -I 29 #OF MODULE5 3 2 9 (P) Pitch 202 t 41� �p4 NEJy� REVISIONS J Cetlin Jo15t 2"X 8" D. FIR I G" O.C. TOTAL MODULE WEIGHT(Lbs) 45.2 96.8 435.E '� „ DESCRIPTION DATE REV] A �} � C Collar Tles 2 X 8' D. FIR I G" O.C. TOTAL LENGTH OF RAIL(Ft) 20.8 13.9 G2.4 C t� �*n-' �+ H Horizontal 5 an of 114 1" MAX. ORGINAL 01-09-2023 ,AIL WEIGHT PER FOOT(Lb5) O.G8 O.G8 O.G8 * fs TOTAL RAIL WEIGHT(Lb5) 1 4.1 9.5 42.4 #OF 5TRANDOFF5 6 4 1 G (PQ (RB) ^ > 7 WEIGHT PER 5TRANDOFF(Lb5) 2 2 2 �0 7034'a1 (D) TOTAL 5TANDOFF WEIGHT(Lbs) 12 8 32 SS1 TOTAL ARRAY WEIGHT(Lb5) 1 71.3 1 14.3 510.0 t 'OINT LOAD 05) 28.G 28.G 31.9 I CONTRACTOR TOTAL ARRAY AREA(5cl Ft) G4.2 42.5 192.7 '\PRAY DEAD LOAD(Lbs/5q Ft) 2.7 2.7 2.G ELEMENT ENERGY, LLC. 7470 SOUND AVE WIND DESIGN SUBJECT 70 DAMAGE FRINIB MATTITUCK, NY 1 1952 GROUND SEISMIC WINTER ICE BARRIER FLOOD AIR MEAN (P SNOW SPeedd Topographic Special ai Wdborne DESIGN Frost DESIGN UNDERLAYMENT FREEZING ANNUAL (C) LICENSE # G74G I-HI LOAD' k HAZARDSs wind debris CATEGORY, Weathering' tine Termite, TEMP* REQUIREDh INDEX' TEMPI LICENSE # 52G89-ME (mph! effects 1 m region zone depthl' 9 1A� Id9 4l6 W E9 MXW 3 TT 1S5�F Y�gS Z005(X 1 5'M9 5f7V F *MANUAL)DESIGN CRITERIA" Indoor Heating Elevation, Latit ude Winter Summer Altitude design Design temperature PROJECT NAME heating cooling correction factor design cooling difference 108 FT 41'ft 1m,F 87H°FF 11000 700FF 745FF 5!05F F C) watd wind � N�r-� Cooling CoincWeutt Daily Winter Summer L J temperature difference heativelocng velocity wet bulb range humidity humidity LLJ Q m freatltlj cooling V J U _ It*F 115111111"IIE 75111101 CN1 WFF CMff[RIM71M) 440W 33ZeFW(1-,RRH z O or SI:1 pound per square foot=0.0479 kPa,1 mile per hour=0.447 m/s. ROOF FRAMING DETAIL n W o z_ 1. Where weathering requires a higher strength concrete or grade of masonry than necessary to satisfy the structural requirements of this code,the frost line depth z strength required for weathering shall govern.The weathering column shall be filled in with the weathering index,"negligible,""moderate"or"severe"for concrete as LL 1 letermined from Figure R301.2(4).The grade of masonry units shall be determined from ASTM C34,C55,C62,C73,C90,C129,C145,C216 or C652. I. Where the frost line depth requires deeper footings than indicated in Figure R403.1(1),the frost line depth strength required for weathering shall govern.The jurisdiction U shall fill in the frost line depth column with the minimum depth of footing below finish grade. MODULE MOUNTING CLAMP :. The jurisdiction shall fill in this part of the table to indicate the need for protection depending on whether there has been a history of local subterranean termite damage. Q I. The jurisdiction shall fill in this part of the table with the wind speed from the basic wind speed map[Figure R301.2(5)A].Wind exposure category shall be determined 50LAR MODULE on a site-specific basis in accordance with Section R301.2.1.4. W L The outdoor design dry-bulb temperature shall be selected from the columns of 971/2-percent values for winter from Appendix D of the Plumbing Code of New York 5TAINLE55 STEEL 3/8" State.Deviations from the Appendix D temperatures shall be permitted to reflect local climates or local weather experience as determined by the building official.[Also BOLT AND r IuT CL_ O Q see Figure R301.2(1).] N The jurisdiction shall fill in this part of the table with the seismic design category determined from Section R301.2.2.1. J. To establish flood hazard areas,each community regulated under Title 19,Part 1203 of the Official Compilation of Codes,Rules and Regulations of the State of New (� York(NYCRR)shall adopt a flood hazard map and supporting data.The flood hazard map shall include,at a minimum,special flood hazard areas as identified by the NRIDGE ALUMINUM RAIL Federal Emergency Management Agency in the Flood Insurance Study for the community,as amended or revised with: ALUMINUM"L"BRACKET i.The accompanying Flood Insurance Rate Map(FIRM), ii.Flood Boundary and Floodway Map(FBFM),and iii.Related supporting data along with any revisions thereto. ALUMINUM FLA5HING 5HEET NAME The adopted flood hazard map and supporting data are hereby adopted by reference and declared to be part of this section. 1. In accordance with Sections R905.1.2,R905.4.3.1,R905.5.3.1,R905.6.3.1,R905.7.3.1 and R905.8.3.1,where there has been a history of local damage from the effects of ice damming,the jurisdiction shall fill in this part of the table with"YES."Otherwise,the jurisdiction shall fill in this part of the table with"NO." 5T KU CT U FA L The jurisdiction shall fill in this part of the table with the 100-year return period air freezing index(BF-days)from Figure R403.3(2)or from the 100-year(99 percent) ASPHALT 5HINGIF ROOF value on the National Climatic Data Center data table"Air Freezing Index-USA Method(Base 32°F)." 5/1 G"x G"5TAINLE55 The jurisdiction shall fill in this part of the table with the mean annual temperature from the National Climatic Data Center data table"Air Freezing Index-USA Method 5TEEL LAG BOLT WITH (Base 32°F)." 2 112"MIN THREAD In accordance with Section R301.2.1.5,where there is local historical data documenting structural damage to buildings due to topographic wind speed-up effects,the PENETRATION SEALED jurisdiction shall fill in this part of the table with"YES."Otherwise,the jurisdiction shall indicate"NO"in this part of the table. WITH GEOCEL 4500 DRAWING SCALE In accordance with Figure R301.2(5)A,where there is local historical data documenting unusual wind conditions,the jurisdiction shall fill in this part of the table with (EQUIVALENT OR BETTER) "YES"and identify any specific requirements.Otherwise,the jurisdiction shall indicate"NO"in this part of the table. AS NOTED n. In accordance with Section R301.2.1.2 the jurisdiction shall indicate the wind-borne debris wind zone(s).Otherwise,the jurisdiction shall indicate"NO"in this part of the table. 1. The jurisdiction shall fill in these sections of the table to establish the design criteria using Table 1a or 1 b from ACCA Manual J or established criteria determined by the jurisdiction. I. The ground snow loads to be used in determining the design snow loads for roofs are given in Figure R301.2(6)for sites at elevations up to 1,000 feet.Sites at [CORRUGATED STEEL ROOF] [FLAT ROOF] elevations above 1,000 feet shall have their ground snow load increased from the mapped value by 2 psf for every 100 feet above 1,000 feet. 511FE7 NUM5EP *) See Figure R301.2(4)B. n TAX MAP: 1000- 123.00-05.00-036.200 MOUNTING DETAIL Fv-4I ?oho Sign Document ID:2A768FFA-K5UYY6UPUWXAXRRVHBPJDYQTL8GFHOTWHDJ9L6AOBUU =DF51GNTING BY: SOLAR ARRAY ON MAIN HOUSE 10.4 kWGY LLC (2G)QCELL Q.PEAK DUO BLK ML-G 10+ 400 WATT PV MODULESCEP CERTIFI(2)STRINGS OF(13)MICRO-INVERTERS29 '(2)STRINGS TOTAL 05 NEkV TO UTILITY GRID SFr �",�y REVISIONS STRING # I C, Ar�f�! �f DESCR PTION DATE RE - - - - - - - - - - - - - ORIGINAL O 1-09 2023 BI-DIRECTIONAL , 0 UTILITY METER 1 -PHAS 240 V t- ------------------- _ _ _ _ _ _ _ _ _ 4 1 2 N POINT OF INTERCONNECTION PER NEC 240.21(B)(1)E G90.G4(A) OF TAPCO LICT I STRING #2 35� SMALL NOT FJ(CE DN 0 QRs I _ CONTRACTOR - ------- - 15CONNECT -_- -- _ _--,�� _� MAIN SERVICE D ___� ---� ___� �_--_� __-� _--� 240 V. ISO A I ` ENPHA5E BRANCH MICRO-INVERTER 72-2-US ELEMENT ENERGY, LLC ENPHASE IQ8PLU5- 7470 SOUND AVE � CIRCUIT CABLE TYPICAL 240 VAC. I.2 I A 97%CEC-WEIGHTED EFF. NEMAG.ULLISTED 1 1 MATTITUCK, NY 1 195, 1 ENPHA5E AC COMBINER 4 AC D15CONNECTTYPICAL 240 VAC.80 A LICENSE # G74G I -HI 1 NEMA 3F-UL U5TED 5Q D D223NRB (2)20 A DOUBLE POLE BREAKER5 240 VAC.GO LICENSE # 52G89-ME NEMA 3R.UL U5TED N L2 L I G N L2 L I (2)40 A FU5E5 G 20A , 20A 40 A I PROJECT PJAME I MAIN SERVICE PANEL N N i-PH.3-W Q 240 VAC G N L2 LI I I N Ix G - -1 I j j I I EXISTING GROUNDING I I I I I O ELECTRODE 5Y5TEM Z I I �-----------� i LLl LLJ I ; C) Z I I - (s) z I I - L------------------------------------- -------------- WIRE if CONDUIT SCHEDULE CIRCUIT CIRCUIT CIRCUIT CONDUCTOR CONDUCTORS MAX. CONDUCTOR CONDUIT FILL CONDUCTOR GROUND GROUND GROUND TYPE CONDUIT CONDUIT AMBIENT TEMP ESTIMATED Voltage Drop(% Q I.D. # ORIGIN DESTINATION SIZE PER POLE QUANTITY DERATE INSULATION SIZE QUANTITY INSULATION (CU/AL) TYPE SIZE TEMP DERATE DISTANCE U 3)0.15(B)(3) 3 1 0.1 5(B)(2a)/(3c) LLJ_CT INVERTERS COMBINER PANEL AWG#1 2 1 4 0.5 U5E-2/PV Wire AWG#8 1 BARE CU FREE AIR 55°C 0.84 80 FT 2.0016 0 OR EMT O Q 2 COMBINER PANEL AC DISCONNECT AWG#8 1 1 3 1 1 THWN-2 AWG#8 I THWN-2 CU PVC I" 450C 0.95 25 FT 0.5% (V 3 AC DISCONNECT MAIN PANEL AWG#6 3 1 THWN-2 AWG#8 1 THWN-2 CU PVC I" 45°C 0.95 10 FT 0.2% ELECTRICAL NOTES SHEET GAME CALCULATIONS FOR CURRENT CARRYING CONDUCTORS 1.)ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION. #I PV Source Circuit Wire Ampaclty Calculation CONFIGURATION 2.)ALL CONDUCTORS SHALL BE COPPER, RATED FOR GOO V AND 90-C WET ENVIRONMENT. NEC G90.8(B)(I)]: (isc)'(#of strin s)'(1.5G) = 19.GG A 3-LINE D I A. 3.)WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY g Modules per String 13 TO, AND LOCATED AS CL05E AS P0551BLE TO THE NEAREST RIDGE, HIP, OR VALLEY. AWG#12, amp GG 'Temp Derate = re I e A Modules per Inverter 1 4.)WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL 20.I G A > 19.GG A, therefore DC wire size is valid. COMPLY WITH NEC 110.2G. #2 Inverter Output Wire Ampaclty Calculation Number of Inverters 2G 5.)DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL Inverter Max Amperage output' (1.25) = 39.33 A Record low temp -I OQC FURNISH ALL NECESSARY OUTLETS,SUPPORTS, FITTINGS AND ACf550RIE5 TO FULFILL AWG#8,ampacity"(Temp Derate)'(Conduit Fd1 Derate) = 52.25 A Voc Temp Coefficient -0.24076/eC DPAr/IUG 5CALt APPLICABLE CODES AND STANDARDS. 52.25 A>39.33 A, therefore AC wire size 15 valid. DC SYSTEM SPECIFICATIONS G.)WHERE SIZES OF JUNCTION BOXE5, RACEWAYS,AND CONDUITS ARE NOT SPECIFIED, #3 Inverter Output Wire Ampaclty Calculation O eratin Current 10.8 A N .T.S. THE CONTRACTOR SHALL 51ZE THEM ACCORDINGLY. Inverter Max Amperage output'(1.25) = 39.33 A 7.)ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. AWG#G,ampacity'(Temp Derate)'(Conduit Fill Derate) = 71.25A Operatinq Voltacle 37.1 V 8.)MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE 7 1.25 A >39.33 A,therefore AC wire size 15 valid. Max.System Voltacje 49.G V SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURERS INSTRUCTION. Short Circuit Current 13.9 A 9.)MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C.VIA WEEB LUG AC SYSTEM SPECIFICATIONS SHEET 1luM6ER OR IL5CO GBL-4DBT LAY-IN LUG. Max AC Output Current 39.3 A PV-5 10.)THE POLARITY OF THE GROUNDED CONDUCTORS 15(positiveJnegative) OR O eratin AC Volta e 240 V 10.)THE DC SIDE OF THE PV SYSTEM 15 UNGROUNDED AND SHALL COMPLY WITH NEC G90.35. TAX MAP: 1000- 123.00-05.00-03G.200 Zoho Sign Document ID:2A768FFA-K50YY6GPUWXAXRRVHBPJDYWTL8CiFHC;TWHDJ9L6AC:BUU DE51GN E DR,AFTING BY: SERVICE METER OI 7 INSTALLATION NOTE ELEMENTENERGYLLC REVIEW BYJ.M. NABCEP CE,RTIFIF © SOLAR PVSYSTEM PHOTOVOLTAIC PHOTOVOLTAIC ( 1 ) ALL LABEL SHALL BE INSTALLED IN 05 1 1 12-129 EQUIPPED WITH I SOLAR BREAKER • ACCORDANCE WITH THE 2017 NEC RAPID SHUTDOWN ® • . REQUIREMENTS. REvisioNs DESCRIPTION DATE � OPERATING (2) ALL LOCATIONS ARE APPROXIMATE AND ow�INAL o1.09-2023 =- -- -- VOLTAGE SOLAR AC LOAD CENTER - OUTSIDE DOM)TR�OIXTET i REQUIRE FIELD VERIFICATION. (3) LABELS, WARNING(S) AND MARKING SHALL BE IN ACCORDANCE WITH NEC O TURN RAPID SHUTDOWN SWITCH TO O THE'OFF POSITION TO SHUT DOWN , - 1 1 0.2 I (B). E PV SYSTEM AND REDUCE -____.-_.._----_.---------___-_- CAUTION SHOCK HAZARD IN THE ARRAY AC DISCONNECT POWR`OTRS5EMMEaALMSU = (4) THE MATERIAL USED FOR MARKING FROM T W FOLLOftVO dOUN6Ef VM DWG"CnLOMIMASSWM MUST BE WEATHER RESISTANT, IN SOLAR AC LOAD CENTER - INSIDE O .wmME,F",_V j -.MAR R COMPLIANCE WITH NEC 1 10.2 1 (B)(3). vn+F('.�RA.i CONTRACTOR w aRuu�R' w�. (5) THE PV SYSTEM CIRCUIT CONDUCTORS ® O7 ® 1 1 "° (> - SHALL BE LABELED INSTALLED IN ELEMENT ENERGY, LLC �FED B'WA DUAL POWER SUPPLY �� 7470 SOUND AVE SOl1RCES.TOTAL RATING OFALL ! + COMPLIANCE WITH NEC G90.3 1 . OVERCURRENTDEVICES.EXCLLDMNG SOURCES:UTILITY GRID MATTITUCK, NY 1195, MAwsDPPLrov AND PV SOLAR LICENSE # G74G I -HI DES N ELECTRIC SYSTEM 1 LICENSE # 52G89-ME CONDUIT - INSIDE BUILDING ARNING ARNING TFUS SERVICE METER i PROJECT NAME IS ALSO SERVED BY A ELECTRIC SHOCK HAZARD I!C()(M PHOTOVOLTAIC�TEk PHOTOVOLTAIC SYSTEM TERMINALS ON THE LINE AND BNOER PANEL LOAD SIDES MAY BE ENERGIZED 00 NOT ADO LOADS CONDUIT - OUTSIDE DUILDING —INTHEOPENPOSITION v. Lu (`() ---- -- -- - ------ Z Q w O — WARNIN — DUAL POWER SUPPLY U^J/ �/ z { SOURCES:UTILITY GRID AND L.L i PV SOLAR ELECTRIC SYSTEM MAIN SERVICE PANEL - OUTSIDE ACAUTIONSOLARCIRCUIT Q 0 CV ® NUO O O O r�im -ACAUTION LL- Lu C) ELECTRIC SYSTEM CONNECTED = mw © PHOTOVOLTAIC SYSTEM DISCONNECT MAIN SERVICE PANEL - INSIDE , OPERATING VOLTAGEOPERATING • POWER SOURCE OUTPUT CONNECTION ® O DO NOT RELOCATE THIS SryEET NAME OVERCURRENT DEVICE A�05 NEkk A" a�p LABELS AC DISCONNECT/BREAKER - DP.A'MNG SCALE 00 � � ® 70344'3 ' N .T.S. 5MEET 11UMBER PV-6 TAX MAP: 1 000- 1 23.00-05.00-03G.200 XR Rails O . XR10 Rail XR100 Rail XR1000 Rail Bonded Splices Now — A low-profile mounting rail The ultimate residential A heavyweight mounting All rails use internal splices for regions with light snow. solar mounting rail. rail for commercial projects. for seamless connections. • 6'spanning capability • 8'spanning capability 12'spanning capability • Self-drilling screws • Moderate load capability • Heavy load capability Extreme load capability • Varying versions for rails • Clear and black finish • Clear and black finish Clear anodized finish • Forms secure bonding Clamps & Grounding O - UFOs Stopper Sleeves Grounding Lugs Microinverter Kits -.WW-N— ..5� Universal Fastening Objects Snap onto the UFO to turn Connect arrays to Mount Mls or POs to XR bond modules to rails. into a bonded end clamp. equipment ground. Rails. • Fully assembled & lubed • Bonds modules to rails • Low profile • Bonds devices to rails • Single, universal size • Sized to match modules • Single tool installation • Kit comes assembled • Clear and black finish • Clear and black finish • Mounts in any direction - Listed to UL 2703 Attachments O FlashFoot2 Conduit Mount Slotted L-Feet Bonding Hardware AOL K_ 9' Flash and mount XR Rails Flash and mount conduit, Drop-in design for rapid rail Bond and attach XR Rails with superior waterproofing. strut, or junction boxes. attachment. to roof attachments. • Twist-on Cap eases install Twist-on Cap eases install Secure rail connections • T& Square Bolt options • Wind-driven rain tested Wind-driven rain tested Slot for vertical adjusting • Nut uses 7/16" socket • Mill and black finish Secures 3/a"or 1"conduit Clear and black finish • Assembled and lubricated Resources - - - - Design Assistant � �� NABCEP Certified Training - Go from rough layout to fully Earn free continuing education credits, NABCEP engineered system. For free. while learning more about our systems. Go to IronRidge.com/design Go to IronRidge.com/training i�J� a�fti f m ww , Aftk IRONRIDGE Flush Mount System Sam Built for solar's toughest roofs. IronRidge builds the strongest mounting system for pitched roofs in solar. Every component has been tested to the limit and proven in extreme environments. Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashings, and is also why our products are fully certified, code compliant and backed by a 20-year warranty. Strength Tested PE Certified All components evaluated for superior ® Pre-stamped engineering letters structural performance. available in most states. Class A Fire Rating Design Assistant Certified to maintain the fire resistance ® Online software makes it simple to rating of the existing roof. create, share, and price projects. UL 2703 Listed System 20-Year Warranty ® Entire system and components meet Twice the protection offered by newest effective UL 2703 standard. competitors. powered by YR Q ror wuwo w e�orE ' Warranty 2021 0 CELLS A.0dn& Yield Security a_ BREAKING THE 2011 EFFICIENCY BARRIER n/I 11�11�I� Q.ANTUM DUO Z Technology with zero gap cell layout boosts module efficiency up to 20.9%. THE MOST THOROUGH TESTING PROGRAMME IN THE INDUSTRY _ Q CELLS is the first solar module manufacturer to pass the most comprehen- sive quality programme in the industry:The new"Quality Controlled PV'of �JV the independent certification institute TOV Rheinland. INNOVATIVE ALL-WEATHER TECHNOLOGY Optimal yields,whatever the weather with excellent �J low-light and temperature behavior. _ ENDURING HIGH PERFORMANCE Long-term yield security with Anti LID Technology,Anti PID ` Technology',Hot-Spot Protect and Traceable Quality Tra.QTM. EXTREME WEATHER RATING (q High-tech aluminum alloy frame,certified for 77//�/ high snow(5400Pa)and wind loads(4000Pa). A RELIABLE INVESTMENT Inclusive 25-year product warranty and 25-year linear performance warranty2. -APT test conditions according to IEC/TS 62804-1:2015,method A(-1500V,96h) 'See data sheet on rear for further information. THE IDEAL SOLUTION FOR: Rooftop arrays residential buildings Engineered in Germany OCELLS MECHANICAL SPECIFICATION Format 74.0 in x 41.1in x 1.26 in(Including frame) (1879mmx1045mmx32mm) 140•(a)9mm) - Weight 48.5lbs(22.Okg) Front Cover 0.13in(3.2mm)thermally pre-stressed glass with °°sj1°0nin1 anti-reflection technology Lam ♦.Oi d gpq 0ala•(4.5mm) Fro Back Cover Composite film 3s.r(esa�Yn) Frame Black anodized aluminum Call 6 x 22 monocrystelline Q.ANTUM solar half cells Junction Box 2.09-3.98in x 1.26-2.36in xO.59-0.71in (53-101mm x 32-60mm x 15-18mm),IP67,with bypass diodes 4°r =nr(>zmnYry Cable 4mm2Solar cable;(+)a49.2in(1250mm),(-)>-49.2in(1250mm) 4.uonma.iaa(DETAA A) Connector StBubli MC4;IP68 Ut 126•(32-) nETNLA a76 7 ) o.aau4.6mm)I�Ioaa(&6-) ELECTRICAL CHARACTERISTICS POWER CLASS 385 390 395 400 405 MINIMUM PERFORMANCE AT STANDARD TEST CON CITIONS.STC'(POWER TOLERANCE+5 W/-0W) Power at MPPI Pmw [W] 385 390 395 400 405 E Short Circuit Current' Isc [A] 11.04 11.07 11.10 11.14 11.17 n Open Circuit Voltage- Voc IV] 45.19 45.23 45.27 45.30 45.34 E E Current at MPP IMpp [A] 10.59 10.65 10.71 10.77 10.83 Voltage at MPP Vmm [V] 36.36 36.62 36.88 37.13 37.39 Efficiency' q [%] e19.6 a19.9 >-20.1 >_20.4 a20.6 MINIMUM PERFORMANCE AT NORMAL OPERATING CCNCITIONS,NMOT2 Power at MPP pum [W] 288.8 292.6 296.3 300.1 303.8 E Short Circuit Current Isc [A] 8.90 8.92 8.95 8.97 9.00 E Open Circuit Voltage Voc [V] 42.62 42.65 42.69 42.72 42.76 c 2 Current at MPP imm [Al 8.35 8.41 8.46 8.51 8.57 Voltage at MPP VMm IV] 34.59 34.81 35.03 35.25 35.46 'Measurement tolerances P.,t3%;Isc;Voc m5%at STC:1000 W/m2,25t 2°C,AM 1.5 according to IEC 60904-3.2800 W/m2,NMOT,spectrum AM 1.5 Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE ws ya Z M M Dw,4Yvs NN bYw n.,.xYY At least 98%of nominal power during 6 first year.Thereafter max.0.5% a z LLQ . ------------------------------ degradation per year.At least 93.5% u W raa -----------'of nominal power up to 10 years.At - LL W - -- i least 86%of nominal power up to W , , a 9a 25yeers. F r0 ----- --- - - - z oAll data within measurement toleranc- w as.Full warranties in accordance with wo goo goo coo raoo the warranty terms of the O CELLS 9 sales organisation of your respective IRRADIANCE(W im'1 c o p u s s country. N 4 reiowon, vEARs Typical module performance under low irradiance conditions in o a comparison to STC conditions(25°C,1000 W/m2) m TEMPERATURE COEFFICIENTS o Temperature Coefficient of Isc a [%/K] +0.04 Temperature Coefficient of Voc [%/K] -0.27 f Temperature Coefficient of P_ y [%/K] -0.34 Nominal Module Operating Temperature NMOT ["F] 109t5.4(43t3°C) m 0 S PROPERTIES FOR SYSTEM DESIGN ° u, Maximum System Voltage Vsys IV] 1000(IEC)/1000(UL) PV module classification Class II a Maximum Series Fuse Rating [A DC] 20 Fire Rating based on ANSI/UL 61730 TYPE 2 Max.Design Load,Push/PU113 [Ibs/ft2] 75(3600 Pa)/55(2660Pa) Permitted Module Temperature -40°Fupto+185"F p Max.Test Load,Push/PUI13 [Ibs/ft2] 113(5400 Pa)/84(4000 Pa) on Continuous Duty (-40°Cupto+85°C) • m 3See Installation Manual QUALIFICATIONS AND CERTIFICATES PACKAGING INFORMATION m ULality C CE lied P iant, 0;1 ct\/I I`T/I (b � I I Quality Controlled PV-71/V Rhainlanq L11V/J �NV/J L�111/J IEC61215:2016,IEC6173Q2( , U.S.Patent No.9.893,215(solar cells), SA® ( (�R Tam, Horizontal 76.4in 43.3 in 48.Oin 1656lbs 24 24 32 QCPv Certification ongoing. Cc.mI.e US ` ` packaging 1940mm 1100mm 1220mm 751kg pallets pallets modules y_ uL an3o ,oil i'i:imn Note:Installation instructions must be followed.See the installation and operating manual or contact our technical service department for further information on approved installation and use of this product. Henwhe O CELLS America Inc. 400 Spectrum Center Drive,Suite 1400,Irvine,CA 92618,USA I TEL+1 949 748 59 961 EMAIL inquiry@us.q-cells.com I WEB www.q-oells.us EN PHASE IQ8 and IQ8+ Microinverters Easy to install Our newest IQ8 Microinverters are the industry's first microgrid-forming,software- Lightweight and compact with defined microinverters with split-phase power conversion capability to convert DC plug-n-play connectors power to AC power efficiently.The brain of the semiconductor-based microinverter Power Line Communication is our proprietary application-specific integrated circuit(ASIC)which enables the (PLC)between components microinverter to operate in grid-tied or off-grid modes.This chip is built in advanced 55nm technology with high speed digital logic and has super-fast response times Faster installation with simple to changing loads and grid events,alleviating constraints on battery sizing for home two-wire cabling energy systems. High productivity and reliability .�.. Produce power even when the Enphase grid is down' 22 • More than one million cumulative% 5hours of testing year limited warranty Class II double-insulated Part of the Enphase Energy System,I08 Series I08 Series Microinverters redefine reliability enclosure Microinverters integrate with the Enphase IQ Battery. standards with more than one million cumulative hale IQ Gateway,and the Enphase A Optimized for the latest high- Enp hase y p pp monitoring hours of power-on testing,enabling an industry- and analysis software. leading limited warranty of up to 25 years. powered PV modules Microgrid-forming Complies with the latest advanced grid support" CERTIFIED Remote automatic updates for L SAFETY -A the latest grid requirements Connect PV modules quickly and easily to I08 Series I08 Series Microinverters are UL Listed as Configurable to support a wide Microinverters using the included Q-DCC-2 adapter PV Rapid Shut Down Equipment and conform with cable with plug-n-play MC4 connectors. various regulations,when installed according to range of grid profiles manufacturer's instructions. Meets CA Rule 21(UL 1741-SA) requirements ©2022 Enphase Energy.All rights reserved.Enphase,the Enphase logo,IQ8 Microinverters,and other 'Only when installed with IQ System Controller 2, names are trademarks of Enphase Energy,Inc.Data subject to change. meets UL 1741. •'I08 and IQ8PIus supports split phase,240V IQ83P-DS-0002-01-EN-US-2022-03-17 installations only. I08 and IQ8+ Microinverters Commonly used module pairings' w 235-350 235-440 Module compatibility 60-cell/120 half-cell 60-cell/120 half-cell,66-cell/132 half-cell and 72-cell/144 half-cell MPPT voltage range V 27-37 29-45 Operating range V 25-48 25-58 Min/max start voltage V 30/48 30/58 Max input DC voltage v 50 60 Max DC current2[module Isc] A 15 Overvoltage class DC port II DC port backfeed current mA 0 PV array configuration 1x1 Ungrounded array;No additional DC side protection required;AC side protection requires max 20A per branch circuit OUTPUT D. :i Q:• Peak output power VA 245 300 Max continuous output power VA 240 290 Nominal(L-L)voltage/range' V 240/211-264 Max continuous output current A 1.0 1.21 Nominal frequency Hz 60 Extended frequency range Hz 50-68 AC short circuit fault current over 2 3 cycles Arms Max units per 20 A(L-L)branch circuit' 16 13 Total harmonic distortion <5% Overvoitage class AC port III AC port backfeed current mA 30 Power factor setting 1.0 Grid-tied power factor(adjustable) 0.85 leading-0.85 lagging Peak efficiency % 97.5 97.6 CEC weighted efficiency % 97 97 Night-time power consumption mw 60 MECHANICAL DATA Ambient temperature range -400C to+60°C(-40aF to+140°F) Relative humidity range 4%to 100%(condensing) DC Connector type MC4 Dimensions(HxWxD) 212 mm(8.3")x 175 mm(6.9")x 30.2 mm(1.2") Weight 1.08 kg(2.38 Ibs) Cooling Natural convection-no fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class It double-insulated,corrosion resistant polymeric enclosure Environ,category/UV exposure rating NEMA Type 6/outdoor COMPLIANCE CA Rule 21(UL 1741-SA),UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B,ICES-0003 Class B,CAN/CSA-C22.2 NO.107.1-01 Certifications This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014,NEC 2017,and NEC 2020 section 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according to manufacturer's instructions. (1)No enforced DC/AC ratio.See the compatibility calculator at https://Iink.enphase.com/module-compatibility (2)Maximum continuous input DC current is 10.6A(3)Nominal voltage range can be extended beyond nominal if required by the utility.(4)Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. IQ8SP-DS-0002-01-EN-US-2022-03-17